Loading...
HomeMy WebLinkAboutDWG 404-3A; PIP 02-03; CARLSBAD OFFICE PARK; 01-08GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. TH/$ PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON TH/$ SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS 00£$ NOT RELIEVE THE DEVELOPER OR ENGINEER-OF - WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL 8£ REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERM/TT££'$ POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF 'f\" AND A SIZE CATEGORY OF CLASS V AS ESTABLISHED BY "BESTS" KEY RATING GUIDE. 5. UNLESS EXEMPTED BY SECTION 301.(b)5 OF THE UNIFORM BUILDING CODE, RETAINING WALLS OUTSIDE OF PUBLIC RIGHT OF WAY REQUIRE SEPARATE PERMITS FROM THE BUILDING DEPARTMENT. 6. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HA$ BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE' CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, · ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWING$ SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (8) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO RECOMMENDATION$ OUTLINED IN THE $OIL$ REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATION$ AND THE " EARTHWORK SPECIFICATIONS " ATTACHED TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL 8£ SUBMITTED TO THE PROJECT INSPECTOR. 14. A PRECONSTRUCTION MEETING SHALL BE HELD AT THE SITE PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION. INSPECTION. SUPERVISION. TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR SHALL SCHEDULE THE MEETING THROUGH THE PERMIT CLERK(438-1161 ext.4323) AT LEAST F'/VE(5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCT/ON MEETING WILL BE MADE BY CALLING THE ENGINEER/NG 24-HOUR INSPECTION REOUEST LINE AT (7601 438-3891.INSPECT/ON REOUESTS MUST BF RECE/VEn PRIOR Tn 2:00 P.M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECT/ON$ WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE OWNER ANO/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. TH/$ PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCT/ON SAFETY ORDERS. TITLE 8 CALIFORNIA ADMINISTRATIVE CODE. THE PLAN SHALL BE PREPARED BY AN ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATION$. 19. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCT/ON. OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERM/TT££ WILL NOTIFY THE CITY ENGINEER. OPERATION$ WILL NOT RESTART UNTIL THE PERM/TT££ HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERATIONS CONDUCTED ON THE $/TE OR ADJACENT THERETO. INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND SUNSET EACH DAY. MONDAY THRU FRIDAY AND NO EARTH MOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. 22. IMPORT MATERIAL $HALL BE OBTAINED FROM. AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIF/CALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE A$ SHOWN AND AS APPROVED BY THE CITY ENGINEER OR A$ DIRECTED BY THE PROJECT INSPECTOR. 26. ALL $LOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE ANO CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED ANO DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT. DRAWING NO. 404-3L, AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE ANO IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE WITH A MINIMUM 0-LOAD OF 1.350 OR ASBESTOS CEMENT PIPE WITH A MINIMUM 0-LOAD OF 2,000. FOR PRIVATE STORM DRAIN PIPES. UP TO 15" PVC MAY BE UTILIZED PROVIDED DEPTH 15 LESS THAN 15 FEET AND BACKFILLED WITH 3/4" ROCK PER SDRSD 5-4 TYPE "C" AND PIPE MEETS ASTM STANDARD 3034 FOR SOR 35 SOLID WALL PIPE. 31. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED A$ A RESULT OF THE GRADING OPERATION. IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES (ABOVE GROUND AND UNDER GROUND) WITHIN THE PROJECT $/TE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATION$ ARE IN CONFLICT WITH THE PROPOSED WORK. 33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT 1-800-422-4133 SDG&E (760)438-6200 PACIFIC BELL (760)489-3441 DANIELS CABLEVISION (760)438-5241 CITY OF CARLSBAD(STREETS & STORM DRAIN) !760)438-2980 * CARLSBAD MUNICIPAL WATER DISTRICT 760)438-2722 * SAN DIEGUITO WATER DISTRICT (760)753-1145 * LEUCADIA COUNTY WATER DISTRICT [760)753-0155 * VALLECITOS WATER DISTRICT 760)744-0460 * OLIVENHAIN WATER DISTRICT (760)753-6466 * BUENA SANITATION DISTRICT (760)565-5657 * AS APPROPRIATE 34. PERMIT COMPLIANCE REQUIREMENT$: A. FOR CONTROLLED GRADING-THE APPLICANT HIRES A CIVIL ENGINEER, SOILS !:NG/NEER. AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE. OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A.8} CARLSBAD MUNICIPAL CODE. SHEET INDEX ITEM DESCRIPTION 0 2 1 PROPOSED PA\/EMOO 0 PROPOSED PAVEMENT 0 PROP-OSED PAVEMENT 0 PROPOSED CONCRETE S¥MIIOL WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS. REMEDIAi.. GRADING. DRAINAGE FACILITIES. EROSION CONTROL FACILITIES. AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS. AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS. REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLS!!IAD STANDARDS 3. THIS SET OF PLANS 4. PIP NO. 02-03 DATED 11 /f2/2002 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK). 6. SOILS REPORT AND RECOMMENDATIONS BY NORCAL ENGINEERING DATED 4/25/2002 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT DATED NIA 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED -1:JA 10. STANDARD URBAN STORMWATER MANAGEMENT PLAN (SUSMP) LEGEND QUANTITY DESCRIPTION SYMBOL ·. QUANTITY 27,414 SF @ CONNECT ROOF DRAIN TO STORM DRAIN 2500 Sf @ PROPOSED V-Gl/TTER 20,983 SF ROOF DRAIN 752 Sf 12 EA 81 lf 65 LF B. PRIOR TO FINAL APPROVAL OF A GRADING PFRM{T -THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE SHffT 1 1/TLE SHEET SHEET 2 DETAIL AND SECTIONS SHEET · ® 6" CURB {TYPE G) DETAIL A ~ 2397 lf DRMNAGE SWALE @ SIDEWALK DET/>JL H DET/>Jl J DET/>JL K G-7 DfJAIL M 1040 LF I I I I I I I I I I I I I I I I I I I I I I I I I I PROJECT INSPECTOR {15. 16.120 A.10} CARLSBAD MUNICIPAL CODE: (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL. SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS (OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEER/NG DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD ANO LABORATORY TESTS. THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE SHEET 3 G/IADING SHITT SHEET 4 GflAl)/NG SHEET SHEET 5 STOIIM /JRIJN SHEET SHEET 6 WALL SHf£T SHEET 7 WALL SHEET SHEET 8 EROSION CONTROL SHf£T VICINITY MAP GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT CITY OF' OCEANSIDE AND ANY SUPPLEMENTS THERETO. HIGHWAY _7e - (4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE \_~ \ I~ 35. UNLESS A GRAD/i~TY~ERMIT FOR THIS PROJECT IS ISSUED WITHIN SIX (6) ,:.(· ,~ ~ p . , 1 , r MONTHS AFTER THE CITY ENGINEER'S APPROVAL. THESE PLANS MAY BE REQUJRED c] ~ 0 :'l ~ 1 NOT TO TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ;(" '--'"C..,,._1 I SCALE ANY SUCH RECHECK. --.. -~ 36. THE SOILS REPORT TITLED BOUR[STON DEVELOPMENT, PREPAREfo· BY NORCAL ENGINEER/NG "'~ "0 c~ '-, ~ DATED 4-25-02. SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. -:1 '0_;;~.~ ~ SITE I ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS ,'l~:,i ••,•.,.·.·· ~ :$-I CITY OF' VlSTA AND SPECIFICATIONS CONTAINED IN SAID SOILS REPORT. -~ T ~ROAD 1 _ •'--~tJ,1/M.~ \ /",..---CORTE , "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT. THAT I :\\ \ ~"-._/ ~ DB. NOGA!. <f)ft l~~~ \.~~ HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS CITY OF CARLSBAD IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: DANJON ENGINEER/NG ADDRESS: 895 E YORBA LINDA BLVD SUITE 202 CITY. STATE: PLACENTIA. CA 92870 TELEPHONE: 714-572-6800 BY: // • I /" ( JljAES D. SCHREDER P.E\J.Jo.: 42915 EXPIRATION DATE: 3-31-04 SOILS ENGINEER'S CERTIFICATE * .J'"4J: CJV\\.. ''"' ~ OF CAl.,\T~ .. I, Ke11'# TiJGl'QI_ . A REGISTERED CIVIL ENGINEER OF THE STATE OF CALIFORNIA. PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS $/TE WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DATES OF !>-!0 , 20oz. AND 4 · Z.°f" • 20 D t:... TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY. WIJJ:i:'':= RECOMMENDATION$. HAS BEEN SUBMITTED TO THE OFFIC ;:,~f r /TY ENGINEER. =,~ ,f "-"' o. •UcL '4, --"" I<!' .,.., ;:> /,,W,,1 /,1111,/ A ::!2~ ~'i! SIGNED: UJ7'vv "·. -v~ ""\· No.841 iii , • c:,::: Exp 12/31/04 ~ G.E. OR P.E. NO.: R.C:i.€ B+I ~*<S' "'.,; . ,,~ * I I ~ orec~\c ~"'- DATE: t 2. ? f DZ-j l"£oFcALl'c:;'I' LICENSE EXPIRATION DATE:_l 'Z._f_·.~-" 1..,./_o_f~----- OWNER'S CERTIFICATE I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THIS SITE. RICHARD T. BOURESTON g/4 / 2~; DATE BY THE ME. AS PACIFIC OCEAN ~-i·:X·:;·:•·.·:-:~:· / AVE. ~t' l,. I 1111 r ~ r I~ I <J ,J ~-I ! ' CITY OF ENCINITAS C"\._J LEGAL DESCRIPTION A PORTION OF LOTS 1 AND 4 Of CITY OF CARLSBAD TRACT 80-34 ACCORDING ID MAP THEREOF NO. 10062 RLE NO. 81-115130 D.R. A/50 BEING A PORTION OF PARCEL '8' Of CERTIFICATE OF COMPLIANCE FILE NO. 86-136023 D.R. IN THE CITY OF CARLSBAD. COUNTY OF SAN DIEGO. ALSO BEING PARCEL B OF THAT CERTAJN BOUNDARY AJJJUSTMENT PLAT OF THE CITY Of CARLSBAD, RLE NO. 1994-0150371 O.R. SOURCE OF TOPOGIIAPHY TOPOGRl>PHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD OBSERVATION METHODS GATHERED ON FEBRUARY 26. 2002 BY SCOTT ESTEP PLS 7066 TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY S'/iWIJAIIDS. PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER: 2130612500 CALIFORNIA COORDINATE INDEX (NAD 83) NORTHING 1,9/i8.000 EASTING 6,246.000 BENCH MARK THE ELEVATIONS ARE BASED ON CARLSBAD CITY BENCHMARK NO. CLSB-066 BEING DESCRIBED "5 FOLLOWS: FD WELL MONUMENT IN CENTER OF BULB CUL -DE -SAC AT EAST END OF OWENS AVE. ELEV=275.076 (NGVD 29) BASIS Of BEARINGS THE BEARINGS SHOWN HEREON ARE BPSED OF THE CENTERLINE OF CORTE DEL NOGAL SHOWN "5 N32'04'22"E ON MAP NO. 10062 FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY. ~ H~JNC. ....., 95 E. Yorba Lindo Blvd~ Ste 202 • -Plocent.ia. 'CA 9267u {714)572-6!!00 FAX(714)572-6850 ® 6" CURB AND GUTTER {TYPE G) DETAIL B (2) PCC SIDEWALK DETAIL C DETAIL D DETAIL E ® PROPOSED 1-WlDICAP RAMP ® PROPOSED HN,iDICAP RAMP @ PROPOSED V-GUTTER DETAIL F 11 PROPOSED DRIVEWAY GS-12 1 2 RETAINING WALL (BY SEl'ARAT£ !'6RMIT) 1 3 PROPOSED 2· Wl!l£ WALL DRAIN DETAIL G 14 @ @) @ PROPOSED 3' WJIJC: WALL DRAIN DETAIL G PVC BACKOllAIN DETAIL SHT 6 PROPOSED ROOF DRAIN lRASH ENCLOSURE ENHANCED PAVING MONUMENT SIGN EXISTING TOP /[Of. SLOPE BOUNDARY PROPOSED CONTOUR EXISllNG CONTOUR Fl.OW LINE STORM DRAIN PROPOSED TOP /fOE SLOPE SEWER WATER ~ OWNER/DEVELOPER DETAIL J GS-16 ARCHITECT ARCHITECT BOURESTON DEVELOPMENT 5500 TRABUCO RD SUITE 100 IRVINE CA 92620 MR. RICHARD E. BOURESTON. SR. (949) 387-4663 FAX (949) 767-5929 'JJ7 lf 1 1 I I 11 6087 Sf I 1 1 1 3 EA /fl:::, 3 EA 906 lf d ~ 1 EA 1330 lf E· ·-·-·3 755 lf --·-326 lf @ MOW SlRIP @ REMOVE TREE @ 6" PVC @ a• PVC @ 12• PVC @ 18" PVC @ NOS GRAT£ @ CATCH l!ASIN SDR-35 SDR-35 SDR-35 D-2000 0 E 3 • @ CURB OPENING CATCH BASIN /IP#A 304-2 b!I 12:!l 6 EA [g 2 EA IHIHJIJ]1 'JJ16 Sf I I 1 EA ---------100U-"-- ---(1000)--- TOP SLOPE =;%E=la;,E' --s----w-~ 970 EA A.V. AIR/VACUUM VALVE @ @ @ ~ 0 AlRIUM GRATE JUNCTl0N Sl'RUCTIJRE JUNCTION STRUCTURE CONNECT TO· CATCH BASIN CDS FACILITY 3" PVC ABBREVIATIONS Af'WA 332-1 />lW. 331-2 Af'WA 335-1 SDRSD D-27 F.S. FINISH SURFACE AWWA AMERICAN WATER WORKS ASSOCIATION GALV. GALVANIZED A.C. PSPHALT CONCRETE B.C. BEGINNJNG OF CURVE B.V. BUTTERFLY VALVE 8.0. BLOWOFF ASSEMBLY BW BACK OF WALK C.F. CURB FACE CL CENTER LINE CLR. CLEAR DISTANCE CML & C CEMENT MORTAR LINED AND COATED CML & P CEMENT MORTAR LINED AND PAINTED COMP. COMPRESSION CL CLASS CONG. CONCRETE DIA. DIAMETER D.I.P. DUCTILE IRON PIPE DIST. DISTRICT DR. DRIVE E.G. END OF CURVE ELEV. ELEVATION G.E. GROOVED END GR BRK GRADE BREAK HORIZ. HORIZONTAL HP HIGH POINT INT. INTERSECTION INV. INVERT L LENGTH L.F. LINEAL FEET LP LOW POINT MIN. MINIMUM MAX. MAXIMUM NO. NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER PA PLANTER AREA P.E. PLAIN END R RADIUS RED. REDUCING REQ'D REQUIRED STA. STDS. STL. SQ. SWLK TC TF TG TW TYP. VERT. w W.L. W/ WT. WW#B 1JT EX. EXISTING RCP REINFORCED CONCRETE PIPE E.W. EACH WAY RWv RESILIENT WEDGE GATE VAL VE FF FINISHED FLOOR S SLOPE F.G. FINISH GRADE S.D. STORM DRAIN FL FLOWUNE SHT. SHEET FLEX FLEXIBLE ST. STREET FLG. FLANGE 0 EARTHWORK QUANTITIES CUT: 3621 CY PLANNING DEPARTMENT APPROVAL FILL: 3:1Z5 CY IMPORT: 1489 CY EXPORT: -CY REMEDIAL: 8772 CY SHRINKAGE: 1241 CY -- STATION STANDARDS STEEL SQUARE SIDEWALK 1040 lf 6 EA 325 lf 323 lf 298 lf 298 lf 18 EA 3 EA 2 EA 22 EA 3 EA 1 EA 1 EA 1 EA 36 lf TOP OF CURB TOP OF FOOTING TOP OF GRATE TOP OF WALi. TYPICAL VERTICAL DOMESTIC WATER WATER LINE WITH WEIGHT ' WATER WORKS DISTRICT NO. 8 DENOTES EXISTING ANGLE POINT - l---l----+------------+---1---1---+----II SHE1ET I CITY OF CARLSBAD . I SH.~TS I :==:::::..::::=:::E:::N:::G=IN:::EE::R:::IN:::G::::::::D:::E:::PA:::R:::TM:::E::N=T==:::::'...'.==::::::: 1----1-----1------------------1-----+---+----+----1 GRADING AND EROSION CONTROL PLANS FOR: CARIB BAD OFFICE PARK APPROVED LLOYD B. HUBBS IIY &, .,..~ UY 12$"$ 1-:Jc, • ..,4 CITY ENGINEER PEh:3889 EXPIRES 12/31 /05 DATE /1\ DA 1E I" •IIAL ENGINEER OF WORK REV1S10N DESCRIPTION DA'TE INITIAL DA'TE INITIAL DWN BY: -m= PROJECT NO. DRAWING NO •. 1-0-lH_E_R-AP~PR-O-VAL--,t--CI_TY_A_P~PR_O_VA-L--I ~~~ ~~; pen PIP 02-03 404-JA --I I I I I I I I I I I I I I I I I I I I I I I I I I I 1-- ~ ~'~ ----· __ . _ _J WALL DRAIN PER DETAIL HEREON WALL BACK DRAIN NOT TO SCALE SECTION A-A c:, "° ,u <O 0 w if) D ~ D.. \ VARIES I 27.50' 1 I NOT TO SCALE SECTION D-D CONSTRUCT :,: R/W 2:1 SLOPE o ~ ~ I ,u VARIES v, co .,.... I :j 0 ~--~ ('J ·~ ~ ~ 1~ ~ -lo CL Ll ·~ 1 ~) I~ .5% fl I il:: --...._ , / I ~EXISTNG \ ~ GRADE \ VARIES C 27.50' I NOT TO SCALE SECTION E-E [I] "' :::, u • <O 0 w if) 0 0.. 0 "' 0.. NOT TO SCALE WALL DRAIN PER DETAIL HEREON 3' l / / / SECTION B-B 0 :;:: w f-0 if)<( X <>: W0 VARIES-+---< R/W I I I I PROPOSED 1SIDEWALK '"'-I ,---- w ~ c:, c:, z u, X w z 'S '-"" 1--5'- -' I ~": 12%::-..... 2'-r17 c:, ,'1! u [:'i SECTION P-P R/W VARIES I (3' MIN) 1 _____ __, VARIES 1 4' ---<VARIES . BLDG FACE SECTION F·F * 2" MIN IN AREAS WHERE BLDG ABUTS LANDSCAPING BLDG- FACE u--VA_R_IE_S-+_4_'--+-+-VARIES j FF 2% ,, =i======H,~ ~ ~ R W :1 S:7 M~ WALL DRAIN~/1 r-----, PER DETAIL -~ , HEREON 1 ' I I ~ '-' 112' !PROPOSED ~ ;:: w ', 1SIDEWALK o2 B 9 JOIN EXISTING AJ , -~ z "' 2:1 SLOPE ~n--5,_ t,i ~~ ~ I Cl x ATRUIM GRATE I c'.5 DO NOT CONNE;T-----;~-;~3•~pv~c;,__.-,~~~Jl2~%;· ~··d'~GS BACK DRAIN TO WAUL BACK DRAIN .. · · , ✓ ATRIUM DRAIN PROPOSED ----,~=:'.:Jlt LJ NOT TO SCALE RETAINING WALL I '-....3• PVC SECTION G·G w BLDG FACE - f-VARIES vARIES IE c-- 1 VARIES f- 1, I i--EXISTING G:J- JOIN EXISTING ___,,, ~ --<.;,----__ f- BLDG FACE GRADING 1 "s~~:,, ¾ )-1 II ~ i"/, ~ f-FF I ~-I==~ I f-:1 1 VARIES I VARIES I I * 2" MIN IN AREAS WHERE BLDG ABUTS LANDSCAPING NOT TO SCALE SECTION H-H 2-._j I-PER DETAIL -u -l I HEREON ~ . t~~" ~ -~D 1 1 -,-,f; --2'._ : g r EX. GRADE ~ -----r'70) --< --I '\ -~ ;!;-....... --... L r-0 ' I~ ~ ,:r: 0 ..... 1 4" NDS ~ '1 ~ ATRIUM GATE ~ x 6" PVC 1 w --1 2.5' El 1 :;:: (SDR-35) 1--1 :g I ,'.; VARIES ~ CL WALL BACK~ I I I I DRAIN ' 2% J ✓---3" PVC DO NOT CONNECT DRAINS _ _,,,-- NOT TO SCALE \ tli r SECTION J·J IE ----_ I 2' 'l' "' ----. - JOIN EXISTING GRADE 3" PVC I -........ < EXISTING GRADE I I .... .... .... .... \ \ \ \ \ \ \ \ \ , ____ V_A_RI_ES ____ -'<'_2_.5__,' 1 \ 2%1 \ NOT TO SCALE ~ 1.5% 6" CURB -u SECTION K·K * 2" MIN IN AREAS WHERE BLDG ABUTS LANDSCAPING ••~~-BLDG FACE FF REQUIRED V LENGTHENED PANEL ~--f1 * VARIES l -4r ~-tt...,<-'t ¼, . _ ~!\I , !Jl;~;;,.\-TOP OF EXISTING -------_ =--'-'i ' 2: 1 SLOPE -I~ \ I 11------EXISTING GRADE \ / \ __ \ \ DEEPENED FOOTING / -PROPO~ED REQUIRED SEE PLAN FOR CONCREfE SWALE LOCATIONS NOT TO SCALE SECTION M-M * 2" MIN IN AREAS WHERE BLDG ABUTS LANDSCAPING 1% MIN 1% MIN FLOW LINE PROFILE VIEW I FFI :1 --r FLOW LINE_/ NOT TO SCALE PLAN VIEW DETAIL K -SWALE * GRANULAR BACKFlLL 1-#3 BAR (1.5' LONG) @ 1 O' INTERVALS CENTERED OVER -+--+-6" P.V.C. DRAIN PIPES \_ r1/2•;~ RADIUS (TYP.) -"'--2% MIN . = ~ ~ J ~F::::;· ::1• _J_~" ~ -I PIPE THROUGH CURB FACE 9.5" @ 10' INTERVALS. NOT FOR USE IN PUBLIC R/W 520-C-2500 CLASS CONCRETE EXPANSION JTX. @ 60' O.C., WEAKENED PLANE JTS. @ 15' O.C. NOT TO SCALE * WHERE FINISHED SURFACE BEHIND CURB DRAINS TO CURB DETAIL 'A' • 6,, CU'RB (/) :::, i 6" 1.5' 1.5" - 1.5" 1.5% MIN NOT FOR USE IN PUBLIC R/W 520-C-2500 CLASS CONCRETE EXPANSION JTS. @ 60' 0.C., WEAKENED PLANE JTS. @ 15' O.C. NOT TO SCALE DET All 'B' -s•• C&G PER PLAN 2% .: ' ,-, . -: . ·.: . 520-C-2500 CLASS CONCRETE EXPANSION JTS@ 60' O.C. WEAKENED PLANE JTS@ 15' UNLESS OTHERWISE NOTED ON PLANS NOT FOR USE IN PUBLIC R/W NOT TO SCALE DETAIL 'CV -SIDEWALK • L,I ~ 45' RAMP \ ~ ~ r GUTTER , 1(2" FOR TACTILE STRIP -.-~-'--'-'--I 1-1/4" FOR RAMP I TYP. LIP OF RAMP DETAIL TYP. GROOVES DETAIL CONTRACTOR TO CONFORM TO ADA STDS BORDER BORDER GROOVES GROOVES 520-C-2500 CLASS '- CONCRETE '\ 8.3% MAX PER PLAN MIN LG lo~~~ FULL 6,f Fu,,._---□-,,C-F-,-,~~~~~~~~~~,,_I\-tO-"C_F ___ .....,_-'---~ 4' MIN \ NOT TO SCALE FULL 6"CF\ DET All 'D' -HANDICAP RAMP 27.5' ·~ I -1 I EX SDG&E R/W m w ~,'-I EASEMENT §s ~ 1 ' -j I PROTECT .u ~ I I IN PLACE e-5' 7 i -r1'w ']) & IPRO~OSED i/1 I --~1 '1--1L-- D.. w I SIDEWALK J_!, I ~ -/ ~ _ _ · / _______ I ~1-1 ~: EX C&G_/ ,/---I '-e::: JOIN EX ;;,-0 GRADE I LEX REf x I WALL w I NOT TO SCALE SECTION C·C 1~ ~ I I I RAMP -<::::· 45' " r GUTTER ~R TACTILE STRIP 1-1/4" FOR RAMP t TYP. LIP OF RAMP DETAIL NOT FOR USE IN PUBLIC R/W TYP. GROOVES DETAIL CONTRACTOR TO CONFORM TO ADA STDS O"CF ~ I') <X) BORDER GROOVES 8' FULL 6"CF , I 4' MIN li-\o_"_c_F _6_, _TY_P_-1I NOT TO SCALE DETAIL 'E' • HANDICAP RAMP 3' 1.5' 1.5' 3/8" LIP~ 520-C-2500 CLASS CONCRETE EXPANSION JTS. @ 60' 0.C., WEAKENED PLANE JTS. @ 15' O.C. NOT TO SCALE DETAIL 'F' V-GUTTER 1 ' X ':.,- - >--~ - f--~ - \_ PROPOSED WALL PVC (SDR-35) o: oi ,--~ ~ SOLID WALL £"( 'l;/t, oo 1------1/ THRU WALL ""$'~~ ji:~~ / o/J. 10~ 1• :~b~'C -2%. - RETAINING WALL BACK ~ ~ . :;Jf:;:;)'>'/)))// , DRAIN -3" PERFORATED , '7/~i • 2&_ PVC (SDR-35) 1;• 0 00 ~;:· 2;, _,S DO NOT CONNECT DRAINS ~ o / I ' CURB - 3" SIDEWALK UNDERDRAIN _/ PER SDRSD D-27 NOT TO SCALE DETAIL 'G' • WALL DRAIN ~ SIDEWALK , I-R/W ,3 0.34' : t---8'--j 2' 520-C-2500 CLASS CONCRETE EXPANSION JTS. @ 60' O.C., WEAKENED PLANE JTS. @ 15' O.C. NOT TO SCALE DETAIL 'H' * 2" MIN IN AREAS WHERE BLDG ABUTS LANDSCAPING BLDG FACE I FF l 1.0' WIDE CONCRETE MOW STRIP NOT TO SCALE V·OUTTER DETAIL 1'M1' -MOW STRI.P CONSTRUCTION NOTES 0 PROTECT IN PLACE (ITEM AS NOTED) 0 ADJUST TO GRADE (ITEM AS NOTED) 1. CONSTRUCT 3" AC OVER NATIVE MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 2. CONSTRUCT 3" AC OVER 3" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 3. CONSTRUCT 3.5" AC OVER 4" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 4. CONSTRUCT 6" PCC OVER NATIVE 5. CONSTRUCT 6" CURB PER DETAIL A 6. CONSTRUCT 6" CURB AND GUTTER PER DETAIL B 7. CONSTRUCT PCC SIDEWALK PER DETAIL C 8. CONSTRUCT HANDICAP RAMP PER DETAIL D 9. CONSTRUCT HANDICAP RAMP PER DETAIL E 1 0. CONSTRUCT V-GUTTER PER DETAIL F 11. CONSTRUCT DRIVEWAY PER CITY OF CARLSBAD STD GS-12 12. CONSTRUCT RETAINING WALL PER SEPARATE PERMIT 13. CONSTRUCT 2' WIDE WALL DRAIN PER DETAJL G 14. CONSTRUCT 3' WIDE WALL DRAIN PER DETAJL G 15. CONSTRUCT 4" PVC BACK DRAIN PER DETAIL SHT 6 16. CONSTRUCT ROOF DRAJN PER DETAIL J 17. CONSTRUCT TRASH ENCLOSURE PER ARCHITECT'S PLAN AND CITY OF CARLSBAD STO GS-16 18. CONSTRUCT ENHANCED PAVING PER ARCHITECT'S PLAN 19. CONSTRUCT MONUMENT SIGN PER ARCHITECT'S PLAN 20. CONNECT ROOF DRAIN TO STORM DRAIN 21. CONSTRUCT V-GUTTER PER DETAIL H 22. CONSTRUCT ROOF DRAIN PER DETAIL J 23. CONSTRUCT SWALE PER DETAIL K 24. SIDEWALK PER SAN DIEGO REGIONAL STD G-7 W=4.5' SEE DWG NO. 404-3 25. CONSTRUCT MOW STRIP PER DETAIL M 30. REMOVE TREE 100. CONSTRUCT 6" PVC (SDR-35) 101. CONSTRUCT 8" PVC (SDR-35) 102. CONSTRUCT 12" PVC (SDR-35) 103. CONSTRUCT 18" RCP (D-2000) 104. CONSTRUCT 6" ROUND NOS GRATE (MODEL # 50) 105. CONSTRUCT GRATING CATCH BASIN PER APWA STD 304-2 W=3.0' 106. CONSTRUCT CURB OPENING CATCH BASIN PER APWA STD 300-2, W=3.5' 107. CONSTRUCT 4" NOS ATRIUM GRATE 108. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 332-1 109. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 331-2 11 0. CONNECT TO EXISTING CATCH BASIN PER APWA STD 335-1 111. CONSTRUCT COS MODEL PMSU20 25 WHERE SIDEWALK OCCURS PROVIDE RECTANGLE PIPE 3" BEYOND SIDEWALK ROOF DRAIN SIZE 6" = 4" & 5" = ADAPTER SIZE 3"x 17" 3"x g Y2 " 3"x 6 ½" ALHAMBRA FOUNDRY ROUND TO RECT. PIPE ADAPTER A-480 (CAST IRON) 6x6-10/10 W.W.M. 2.0' ON EITHER SIDE PIPE #4 BAR x 4' L0NG \ VARIES SIDEWALK " VARIES BLDG FACE CURB OR C&G .----~..,...>, \_i,."'-',,,_---rl-~ .. ~ ,r11-~------- EPOXY ALL SIDES ROOF DRAIN PIPE ',,, I I I I\L ALHAMBRA FOUNDRY A-470-- RECT. PIPE. SEE CHART -----f--- I ABOVE TO MATCH ARCH. ROOF DRAIN NOT TO SCALE NOTE: FOR NEW CURB CONSTRUCTION ONLY DETAIL 'J' -ROOF DRAIN PLANNING DEPARTMENT APPROVAL -~=· ·=o~,;;,;.c>c>. t;~~~,,,.i ~· =-.,__ D.m:: I /2:=1-/0;, M!ClliEL J. Hllf:lJIDWI, PLANNING DIIIECTtlll ~ f'l 1 • L AL I. •• -"-C...=.cc...:c.---,,,(~5GiNl!D==,~lc.=..--+----DATE! \ ;-,_ "1/ D 3, RECODENDED BY: £1'-IM I'--QU1<,,ES.H':[ (PRINT NAlli) "AS lll'ISPECTOR -./ BUILT" rxo{o"tf-u,r,~ DATE PROPOSED 0 4.5' : 4.33' I , . .. I 2~ !57 ~ - 4 '-' -~ -.L -JOINEJ7 I l_ 1----1----+----------------1-----1---+----1----1 GRADING AND EROSION CONTROL PLANS FOR: -g::---.• ~ -2%4'-~ •PROPOSED GRADE 17-J TJ, ""' _ SIDEWALK I -fp-,:':,~-~ ~ I c:, ~ PROPOSED I c'.5 ' Jl"-4 -REf WALL x · OPOSED PROPOSED u.J • INEERJNG.l!N"C. EWALK RET WAUL NOT 7'0 SCALE O = f-4 .. r~ · SECTION N·N ' ' 1 1895 E. Yorbo Lindo Blvd., Ste 202 · = Placentia, "CA 92870 (714)572-6800 FAX(714)572-6850 DATE ' TIAL Et,IGINEER OF WORK DATE INITIAL DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL CARlSBAD OFFICE PARK APPROVED LLOYD B. HUBBS lfy' 4,.,,?efC du-:~-/-,J,p-cJ CITY ENGl'l<EERPE23889 EXPIRES 12/31 /05 ,,DATE DWN BY: ELR · PROJECT NO. CHKD BY: R,$:S:: PIP 02-03 RVWD BY: 01:g DRAWING NO. 404-3A --_j ' ' 'PROPOSE'.0. 12:1 SLOPE . \~-~ ·;7,.a,.. ', '·21 ' ' ,1 • 4,,_,i_.- ' , .. ••" ,,_ .. -· -\ / 14 .: • I ,; ,,11 i!'1 ,, 10.44! l ' ' ; : ' / ! , : I '' I' i ,t .L.,: ....... ' ' ' i.GR-a ! ~-::..;'_ ' )_; ' -----------! _.-'/""'. : 10. ' . . 210. 9 , . ._, , , Ii 210. 9 ...:. ''·. :-~ -r-~.''f2R....;;,,, .,., I ·: ,._'CJ1fJ • ' ·, ,'l---.. I 1 I I I I I I I -+ I I I SEE TRASH ENCLOSURE DETAIL HEREON ----212-:- H - LIMITS OF 3, B 0\1£R-E:x £Low BO OF FOOTING TTOM TYP. ALL BLDGs 5.0' DEEPENED FOOTING REQUIRED LIMITS OF OVER-EX 3' BELOW BOTTOM OF FOOTING TYP. ALL BLDGS / BLD.G E FF/209.3 ' ,----WALL B SEE SHEET 4&6 WALL C SEE SHEET 4&6 209. FF 208. , DEEPENED FOOTING REQUIRED I 209.03 \-II'-L r----x-/ _, ' \ I N ..: .· ,, 00 N':i,/ .--,-\\ O') VI Y • •l t "' "- "i r2:os ..... CF > • ,,, . 210.37 5; ' I ! I / ·11 . • / I , _.:2 / 212. 6 TC ; -11 1\ 7ij f.S·!ff1 i' ,1 I , I i I i' I ------------- ' ' ' 210.00 F 210.00 .. ... ,ACS_'"'" ....... ,_,.,...... ................. . ........ ,,, •. , .... .. G •··••• 209.5 TG-F. ,80 L I BLDG B FF =210.0 I 23 J---tt-'1 LIMITS OF OVER-EX 3' BELOW BOTTOM OF FOOTING 1YP. ALL BLDGS 7 DEEPENED FOOTING REQUIRED 8" SEWER 7 23 25 J----11,1 FUTURE DOOR I I I I l· I I I I EASEMENT NOTES: TITLE REPORT ITEM No. DESCRIPTION EASEMENT IN FAVOR OF SAN DIEGO GAS & ELECTRIC FILED AS 81-252845 O.R. ON FILE IN THE SAN DIEGO COUN1Y RECORDERS OFFICE GRAPHIC SCALE ~ o 10 ro 40 1""1 ~-----~--·1"""1111'11, _1_; ! ( IN FEET ) 1 inch = eo fl I t OS g, "' " ,~ ' " I .89 I -END, so; +69.01 IT SIA " ,;212.16 FS <t_ DRIVEWA iSTA: 3+48. 0 )i I I ·FL1 20847FL 31' " I -~.... I 1 "' .5% r· · · · 2s· I _: --~ 0 ; i ' ; i:';i_-j _· :_.: ' ' -: : ' ·' i ' : :~ (,1 0 • • • • r· I PC = 5#-3/ 38 OS ONST 11 C 0 5.0' " ' I :: i LINE OF SIGHT SEE ENLARGED AREA B SHT 4 • a_ :t I I ~ ----+---;+-+--LINE OF SIGHT \ ; C C •• i J I • ' CONTRACTOR NOTICES: CONSTRUCTION NOTES 0 PROTECT IN PLACE (ITEM AS NOTED) 0 ADJUST TO GRADE (ITEM AS NOTED) 1. CONSTRUCT 3" AC OVER NATIVE MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 2. CONSTRUCT 3" AC OVER 3" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 3. CONSTRUCT 3.5" AC OVER 4" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 4. CONSTRUCT 6" PCC OVER NATIVE 5. CONSTRUCT 6" CURB PER DETAIL A 6. CONSTRUCT 6" CURB AND GUTTER PER DETAIL B 7. CONSTRUCT PCC SIDEWALK PER DETAIL C 8. CONSTRUCT HANDICAP RAMP PER DETAIL D 9. CONSTRUCT HANDICAP RAMP PER DETAIL E 10. CONSTRUCT V-GUTTER PER DETAIL F 11. CONSTRUCT DRIVEWAY PER CITY OF CARLSBAD STD GS-12 12. CONSTRUCT RETAINING WALL PER SEPARATE PERMIT 13. CONSTRUCT 2' WIDE WALL DRAIN PER DETAIL G 14. CONSTRUCT 3' WIDE WALL DRAIN PER DETAIL G 15. CONSTRUCT 4" PVC BACK DRAIN PER DETAIL SHT 6 16. CONSTRUCT ROOF DRAIN PER DETAIL J 17. CONSTRUCT TRASH ENCLOSURE PER ARCHITECT'S PLAN AND CITY OF CARLSBAD STD GS-16 18. CONSTRUCT ENHANCED PAVING PER ARCHITECT'S PLAN 19. CONSTRUCT MONUMENT SIGN PER ARCHITECT'S PLAN 20. CONNECT ROOF DRAIN TO STORM DRAIN 21. CONSTRUCT V-GUTTER PER DETAIL H 22. CONSTRUCT ROOF DRAIN PER DETAIL J 23. CONSTRUCT SWALE PER DETAIL K 24. SIDEWALK PER SAN DIEGO REGIONAL STD G-7 W=4.5' SEE DWG NO. 404-3 25. CONSTRUCT MOW STRIP PER DETAIL M 30. REMOVE TREE 100. CONSTRUCT 6" PVC (SDR-35) 101. CONSTRUCT 8" PVC (SDR-35) 102. CONSTRUCT 12" PVC (SDR-35) 103. CONSTRUCT 18" RCP (D-2000) 104. CONSTRUCT 6" ROUND NOS GRATE (MODEL # 50) 105. CONSTRUCT GRATING CATCH BASIN PER APWA STD 304-2 W=3.0' 106. CONSTRUCT CURB OPENING CATCH BASIN PER APWA STD 300-2, W=3.5' 107. CONSTRUCT 4" NOS ATRIUM GRATE 108. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 332-1 109. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 331-2 110. CONNECT TO EXISTING CATCH BASIN PER APWA STD 335-1 111. CONSTRUCT CDS MODEL PMSU20_25 \-.U:.....Gel4S'FR\:JCl3" Pvc (S00=3&,...-F'ER SD~rr-D=-~ '"~_,.,"" I 115. Ct>Al~~a-.. •:::s.-7?50 ;?:A~c~~~~ s~°. .. ~-r ••·•~•:;:.,•;,Oii<. '~'-A~n,-,,•;,o. ~-·-"'"--...--' TREE . 1 2 1 4 ' "··•···.•··.:.•·, •.•. •.·.•.• •. ·.;.:,-.·,_ •. ,·,: .•. ' .....•. ·••·· . p 30 2~;~ . '.~ ' ·.:,),)\~---:·· 17 \~ ...f • -f<) "';:; 213 213· 4TC -14Fs C 2.30 TRASH ENCLOSURE DETAIL SCALE: 1"=10' 1. ALL WORK DONE IN RIGHT -OF WAY PER SEPARATE PERMIT 2. CONTRACTOR TO VERIFY FLOOR SECTION PRIOR TO GRADING OF PAD SPECIAL NOTES: 1. SEE SHEET 4 FOR RETAINING WALL LAYOUTS 2. SEE SHEET 5 FOR STORM DRAIN LAYOUT (SEE SHTS 3-4 FOR TOP Of GRATE (TG) ELEVATIONS PLANNING DEPARTMENT APPROVAL "AS BUILT" 5 /M.<1Pa e~@ 1 DATE: 1 /1..=r/o 3 (SI! ) ~~ J/.ua,• k-i!i~ .IIICIIAEL J. tml/DIIJJBR, {',LANNING DIIIICTOII DATE ';,N,MN?A (~µ\~ DATE: 1 /2.1/ D~ IIECOMMl!NDED BY: SA\ I'/\ f', & U ~ E S\-f Y (-NMIR) 1-----+--+--------------+---;---t-----;----i I SH3EET I CITY OF CARLSBAD ~ ENGINEERING DEPARTMENT ~ :=:==-==========::.::::=:::::; 80 ; t. Yorba Linda Blvd, Ste 202 Placentia, CA 921l7u (714)572-6800 FAX(714)572-6850 ENGINEER Of WORK REVIS10N DESCRIPTION DATE INITIAL DATE INITIAL O'lHER APPROVAL CITY APPROVAL GRADING AND EROSION CONTROL PLANS FOR: CARI.SBAD OFFICE PARK APPROVED LLOYD B. HUBBS tJ'r ,.&,....,...,(...,,,CC,,,==,.-,LJ'.;,c.,.e·~/A1/,,=§ae;p:cc+--M~• M,-----,--,--l•3D -a 3 CITY ENGltltEE'.R PE t'.3889 EXPIRES 12 31 05 DA TE WN BY: ELR PROJECT NO. CHKD BY: P,s.::r:: PIP 02-03 RVWD BY: Col<. DRAWING NO. 404-3A I I I ( ( I ( 12 I r A ~EE PR,OFILE $HT, 6 I I I r I • : 107 "' 1 RETAINING WALL A ATRIUM GRATE LOCATIONS 1 +25.0 1 +50.0 1 +79.0 2+00.0 2+15.9 2+58.3 I ~""'1 107 107 14 ' I I i' ,' I ,i I •' I I I , - - - - - ---' ----,- 1 + 22.35 i'. PT R WALL D 12 1 +00 BEGIN RET 1 2 ALL D SEE PROFILE SHT la , I I : I 11 "' i I I I I 208.68F~ , ~c; . <:,''?, ...__""'"' 8" SEWER , 209.P9[D"Gt;> 209 208 'i'' 209.4 TC 208.9 FS 7.0' • -FL 6.0' 0 +, cs .. SEE ENLARGED ·~JW+~~:=:2r~r~~ AREA A HEREON -/ ----7 I ii I 11 I Ji I I 213.4 •. --... ? 1 ~· F ii ~., ,. IS "'·,\ 206.· 'TG-'-FL , L .,,,:,;,, I'. : I :1 I i :1 4TC 4FS -----s r------~ l() .. ·__ I a 1 NN I 7 ,-,~,.s:16,la=±=!=aii]JJ -···----....... °" l!MITS OF OVER-EX 7 LL ~ ,3' BELQW BOTTOM .. ·:s:, □ I ~ --~ ~~db&;9l,1 .• :J ii OLL l() a:, 0 N, J" fiJ r,1. i ,2/_i/Ji '[, LIMITS OF OVER-EX I · · ' ; • ~1 < • ·1 I I ',,./2/5. >----llll I .1' .·' ; ; • l '" · 3 BELOW BOTTOM . , ,; .,, i 'loJ 1 ··· 1-1.5% : · ~P:~IN;LDGS .... · 23 hl'!I--..JI '; • f)ff ~ ; 0 t '· .... .. ............. 2%. / · , 1 ,' ; , , /I ....,,.~ \Jl Z 1 I i , . V a. ::Jli\4W.Jt~Vli"ilt. · '5.0 _...... , ; . ; . 1: , /IL/ 1 : :...J I M~:.:+1 ..... 1.H 101.4... ... -·--BLDG D 1 . . , •. , . . , . OC) w· , : OF FOOTING ; TYP. ALL BLDGS a:, . ~1'J~-r-,;·-;;J.r=_.::_:rs;~t=====iiiJ::J;:::=~t·::=··, 25 FF =208.5 ·:: 1 '-/F/.;;;!;,:1 1 i_' 1 '' '' '/~/::.:,~:,,: ~ p ! cB··L/DG/ C l . .ii I x' . --""· -i;;;:::Jf.+=-+-'-'=42oL..,+.._,.-....___) DEEPENED I / ii/ ' w LU I 23 1FF =208.3 L ~igV1~!(~ , 'i, "'"1;;,-,1/f,i .!-lllt::===-\ / .,. ,.• ~~ /, i , . ' . a: l . '\ 1. --,,DEEPENED I /./"" 1.11r . ./ ·i jf • ~ 0 0 • c., z t:i X uJ 5.0' i' l :l i' I I I I I I I ---_j ----- 1~=-~~-.,~"'-----'-'-==w~=--L~o-_-_-w-----w-----~---~~--w--~--- 1 -- L 0 \··\i ·~ ~~;:;:ii::::g0:;;\NG~RE~D~,.~·~F~~~=====:;;;~~~~ , -~LL~Nij :r: 20s '=-:,,i!--=:i ""'.,'i's"<: ~',le~':, rr,~~ , i 11 ,~r ---i,-1 o-1---0 7-. 2·.0.1.2 A'. 1 ~'1:'s-:::: / ~,. ••1z ---~ ----i. --~-...µ., , -------207-,. ":'SI'-"'<'-"' e.3 L · // ;L",i"' /...,.,__, • .. \. FG I. ~,2 (0 I ~ 2:::::::::::=====~:,e,~t-~~ . -. -EQ .'; . ! '1, . ''<i'r · .. 1\ -N , .63 \;:. . _. __ . --· -. ··:_···. ,,,.~;,;;-r ---.;,: _ -1Jj -• .1 ; j ,. t,9'-,f-__!_~'..,.!:~ 1 . '\ ·w ,~\\, '\. ~ 207 / 1 % MIN --'--QI• ;;a:;ca-"ff".Sf ~~~ -•. • ·---- -.. -~-.. ; ~~~·"/✓ i ' /Jg/ /II ," .. ii,~~b.'1---'..,,__l , =Jl--r-;=>-!.. I ® .... ';,;,. I '\. NLL •.• · -· .-ii!ii ........ •·.·.··-·······-2·0···4'···.,.G····::~ '·.• t--+i... , ; Ill • I ",.'"••._ -::-•i;;; _, ----,,~ a-•-••••~••~•~~••--•-" ~,--J:• - -,,......,__ ~ RET AINlfj.G_.Yl_All LAV OUT DET All I ",. _ _,......._~~..._ _ _,, '.,, ca d'l;\ -------------------2 sPRINK!.E."'L ___ ........ -"'-------· 1 ----."~ r---t c-:::.=---.-.--.-.-:---.;,: ---------206 ... ... . .... . :=.~ .. ~ ... , ... ,.:,::::~.:.::: / j '1 + ----:;= • . . ... ····-, ........ -··· ..... , •.• -.. ,.... · •• -• / /• .· · ~~~~~-JJ,!1!:b...f-{ 12 -. . • .. .. -... I .~.;=· -.;~-.~·•· .... _::·::-.·.=•;·--·~· -~··[···'•· ... ~~·.--.: ... ;;:)... ·:_::_ ••.•.•... •.\: ..... ,' :· .:: .':::J ",;,,1,:_,'';,j~":::. ;,c]0r~~ .. ••· .. · .. -.:.:·:::':';;~:,.·'. .j~~f-=t==:.:~-~ii~[i~{~~=\f=1f ,ii{: -:·::~~·= .. -::.::. ·:·· .:_:·:.: .. ---........ :: ...... : ... : ....... --. ~-. --,--"······.· ..... ·· ·1·iJ7--·: ,/"°9,~~:/ ; ti/I<''." ... , \ .,,.--·-----SGALE: 1 '=40' -:I"\ ~0001:. SIG+.! lt> 151:Htt.lt> SWALE RjW 1.0' MA)( NiW LOCATION I 54• i SIGN RELOi~~~ION DETAIL MO'/£ AND U!,.OCIITE SWALE STA: !i-1-06-83 ----------- RELOCATE WAI.I. A$ NE6t>l!O /(' ST STA: i1-t-i6-1~ ~ D~~~~:tT:~;;~~Ft:~~~1/ I ' .1 SCALE:1"=10' I 3 7 TC . ·,.,__.,,-..,~ ' i; '-' \ •,,'lie. ' ....... '-( " --...... -t / i .:..., ! ii I f , ;,~;:',!'."' -71 ••• : / ii : --.· .. -c ::.~,,~ .,., • .... , ...... ,~c=:.;·=--•·'-="'1 "·--'~"·= ........ ,=1 0° ... + .. <.·. --.~ .. :~=:::,; .. ,-."~ w . \ •·,,--.,,m\, ~'\ ,""::~511~-·l!E~-S=s,!!-~R!>!-E'!!LO~~:~-~;~dl~'.!l!"Sl i I ..._,,,\ r .__ a:, d ---__ ___,__ _ ___ .....,__ 11 2 EXISTING 12· ACP WATER ~ ~ r-_, "' .. ,"--../. ! " o.,, ... \. ./"-.. _,,,,-..,..__.,,.I s -------------------u u: It,. Ir, 1!, ------0,.-.,..--. -----. -----. -----. 1-------. -----,.... "' "'-...__,. '-... . ,~ -~ s--------s ;!~--:--~f!~--------e--.i/9--------_ 0 ~ _ ___________________ s~_o~_,_r~CT_io_N_~e_,'"_IL __ • __ --1-____ •_ __________ ~..L_~------•_°"'_· ---· // ill/ ' // ----------·,,,,, I 0 PROTECT IN PLACE (ITEM AS NOTED) -~:·\,.\ 1 ,,,,,,,,.----------------------------------------------------··--~----~~~- 0 ADJUST TO GRADE (ITEM AS NOTED) ENLAR~ED'\AfiEA ~ SCALE:1"=10' I ) 1 1 1. CONSTRUCT 3" AC OVER NATIVE MINIMUM-FINAL SECTIONS TO BE I ~-'-__ I BASED ON FINAL R-VALUE ' 1 2. CONSTRUCT 3" AC OVER 3" AB MINIMUM-FINAL SECTIONS TO BE II 11 . ·• •, BASED ON FINAL R-VALUE 3. CONSTRUCT 3.5" AC OVER 4" AB MINIMUM-FINAL SECTIONS TO BE I I BASED ON FINAL R-VALUE I I 4. CONSTRUCT 6" PCC OVER NATIVE I I 5. CONSTRUCT 6" CURB PER DETAIL A I I 6. CONSTRUCT 6" CURB AND GUTTER PER DETAIL B I I 7. CONSTRUCT PCC SIDEWALK PER DETAIL C I I 8. CONSTRUCT HANDICAP RAMP PER DETAIL D I I 9. CONSTRUCT HANDICAP RAMP PER DETAIL E I I 10. CONSTRUCT V-GUTTER PER DETAIL F I 11. CONSTRUCT DRIVEWAY PER CITY OF CARLSBAD STD GS-12 I : 12. CONSTRUCT RETAINING WALL PER SEPARATE PERMIT 12 1 +32.5 1: PT 13. CONSTRUCT 2' WIDE WALL DRAIN PER DETAIL G RET WALL H I 14. CONSTRUCT 3' WIDE WALL DRAIN PER DETAIL G I 15. CONSTRUCT 4" PVC BACK DRAIN PER DETAIL SHT 6 12 1 +41.17 END I 16. CONSTRUCT ROOF DRAIN PER DETAIL J RET WALL H 17. CONSTRUCT TRASH ENCLOSURE PER ARCHITECT'S PLAN AND CITY SEE PROFILE SHT 7 OF CARLSBAD STD GS-16 18. CONSTRUCT ENHANCED PAVING PER ARCHITECT'S PLAN 19. CONSTRUCT MONUMENT SIGN PER ARCHITECT'S PLAN 20. CONNECT ROOF DRAN TO STORM DRAIN 21. CONSTRUCT V-GUTTER PER DETAIL H 22. CONSTRUCT ROOF DRAIN PER DETAIL J 23. CONSTRUCT SWALE PER DETAIL K 24. SIDEWALK PER SAN DIEGO REGIONAL STD G-7 W=4.5' SEE DWG NO. 404-3 25. CONSTRUCT MOW STRIP PER DETAIL M 30. REMOVE TREE 1 00. CONSTRUCT 6" PVC (SDR-35) 101. CONSTRUCT 8" PVC (SDR-35) 1 02. CONSTRUCT 12" PVC (SDR-35) 103. CONSTRUCT 18" RCP (D-2000) 104. CONSTRUCT 6" ROUND NDS GRATE (MODEL # 50) 105. CONSTRUCT GRATING CATCH BASIN PER APWA STD 304-2 W=3.0' 106. CONSTRUCT CURB OPENING CATCH BASIN PER APWA STD 300-2, W=3.5' 107. CONSTRUCT 4" NDS ATRIUM GRATE 108. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 332-1 109. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 331-2 110. CONNECT TO EXISTING CATCH BASIN PER APWA STD 335-1 111. CONSTRUCT CDS MODEL PMSU20_25 112. CONSTRUCT 3" PVC SDR-35 PER SDRSD D-27 12 1 +37.0 END RIT WALL G SEE PROFILE O" CF SHT f'-LL 0 X ~ ~ l() GR-BRK -+--.... 1 +00 BEGIN ET WALL G SEE PROFILE SHT 7 "' 0 ~ N 1' I I ~ I ,. ,. : [~ EXISTING 6" C&G , SDG&E FACILITIES SDG&E EASEMENT PROPOSED STREET LIGHT LOCATION EXIST! NG STREET LIGHT TO BE RELOCATED 1 +00 BEGIN 12 RET WALL H SEE PROFILE SHT 7 CONTRACTOR NOTICES: 1. ALL WORK DONE IN RIGHT -OF WAY PER SEPARATE PERMIT 2. CONTRACTOR TO VERIFY FLOOR SECTION PRIOR TO GRADING OF PAD GRAPHIC SCALE 2J) 0 10 20 "° eo ~-ad I 1 ___ _____JI (IN FEET) 1 inch = 20 ft. PLANNING DEPARTMENT APPROVAL "AS BUILT" IMtl&t~M:oCk"" ( . DATI!: I /z;+/o~ IIICllAEL J. IIOJ;ZlfflJRR PLANNING lllllECTOR DATI: I /2.1/ 0~ RllCIIIIIIENDlll BY: S I" IM :f\ & \JRf, SH 't (PIIIIIT NAll£) • 1---l----+------------J....---l---1----1-~ LI S=HEtE=T '...=I =C=I=TY::::::=:::=O=F=C=A=R=L=S=B=A=D=' ~' S=HEEB=T=S I ~ ENGINEERING DEPARTMENT DATE INITIAL DATE INITIAL DATE ENGINEER GF WORK REVISION DESCRIPTION OTI-IER APPROVAL CITY APPROVAL GRADING AND EROSION CONTROL PLANS FOR: CARLSBAD OFFICE PARK APPROVED LLOYD B. HUBBS 6Y' .e-4~· .. l?w!,,C:"'"'"'~~/r....,J,.v,;,=:.:~q.~!!!!..~1G. ___ ~_~ /·3~ -41"3 CITY ENGiNtER PE !5889EXPIRES 12 31 05 DATE DWN BY: ...tl,.B__ CHKD BY:~ RVWD BY: PE@. PROJECT NO. PIP 02-03 -------- DRAWING NO. 404-3A ' - I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I _j • I I ' (/ > I I . -- . -w -/ ./ ;~:-., ----~ • -,,-----w 20' Wto / -I ER - oj" n ___ ~ -~ I fASEMrN-i:-~------·r I I , I I I I I I , I IW I! I OJ, I I I I l .... .• / ..._,:::_ -.-) ~ ::::::--_ ___ / ----,,-1·--··t1+ .. -... _ ;,;· ,"") ----- i'----,,--.. "-•~ c-,J i' _-'"•-;-"·-~ -~-h ,.,,_,,,.,,,:.,,,o,L, { ! f ' ' ' .>;c:i>.s,,,_,,,_,.._, e-"' '·""-""'-'"· : 0 a,"'> ' I-f': Oz I , I I OJ r---:- TG ~~ 11"='~= "' A • 7 INV ( 105 ',r<") I ~ '_j 102 ' z . -' ll) "' IQ ") o--.,, N 2 4"-'-"~'-" I ..-+-11~~=-li t-i l 1' i 206. 7 TG • · -· l!' 204.71NV •' r-. (0 . 0 ' ... ,,,. ~ ; ' ';---' ' 100 i I : _: ,'+--'--1 "' 1...-t, (l'.: w ~ (/) "' 0 w (/) 0 Q_ 0 (l'.: Q_ -f I ~r. I 2+-- 103 --- 16 I r"'•"" -·•·· • ,, •.•. ·. . , •. -..I _ ........ "-"""-, ' I I 8" WAT R ! , ++--""rl+-'• I I I • IH : I ; I v (I I I I I I I I • I I (I I I I !I II I I '/ I I I I I I I < , I I I lf, 0 :[ EX 18" ,; RCP ., :., .o,i!,, . 1~~·45 • '°I i I 8 ' 11 i i 1"----SO -----SC -_ ---M -----M ---~- ------------------ ----"'" C\t' . ,....__________ , _____ -;--_-~~--=-, --1, ---, ---sCAM I NO WI DA -ROlilLE --, ---,-~ -, ---, ---, 8 CONSTRUCT STORMWATER POLLUTION CONTROL DEVICE CDS TECHNOLOGIES INC. MODEL NO PSU20_25 WITH GREASE AND OIL SEPARATION (NO KNOWN EQUAL) (PHONE 408-779-6363) TO BE ACCESSED FOR MAINTENANCE FROM PARKING LOT STORM DRAIN LINE TABLE LINE LENGTH BEARING SIZE L1 20.92 S32'04'22"W 18" L2 4.12 S45"04'51"E 1 8" L3 18.59 S32'17'07''W 12" L4 82.36 N57'55'38"W 18" LS 78.8! N32'04'22"E 18" L6 18.45 N85' 19' 19"W 8" L7 5.28 S46"31 '22"W 8" LS 8.38 N81 "23'28"E 18" L9 101.40 N39'08' 58"E 8" L10 44.11 S32'04'22"W 6" L 11 39.18 N57'03'08"W 6" L12 29.61 S34' 33'08"E 6" L13 23.65 N45' 48'08"W 8 .. L14 16.30 S10'26'52"W 8" L 15 51.17 S42"24'07"W 12~· L 16 26.92 N49"57' 15"W 12" L 17 22.12 S79'33'08"E 12" L18 61.94 S53'50'21 "E 8" L19 52.55 S31"23'12"W 6" L20 49.84 N78'27' 16"W 18" L21 73.97 N57'55'38"W 18" L22 18.73 N77'04'22"E 18" L23 32.47 S40'33'58"W 12" L24 26.73 N32'04'22"E 12" L25 10.59 N77'18'06"E 6" L26 9.89 S59"59'09"E 6" L27 54.84 S43"28'3_8"E 18" L28 118.43 S59"48'57"E 18" L32 35.07 S75'11 '21 "W 6" L33 11.97 S79' 34' 12"E 18" L34 20.01 N26'44'56"W 8" L35 43.60 S63' 15'04"W 12· L36 26.39 S32' 17'07"W 12· L37 36.03 N55'07' 19"W 8" L38 48.14 N58'59'12"W 6" L39 49.04 S22'50'25"W 12" L40 44.43 S36'05'08"W 12" L41 43.81 N30'11 '21 "E 6" L42 5.08 S85'23'59"W 18" SECTION X-X 1 o· 10' 2.75' 10' I- STORM DRAIN CURVE CURVE LENGTH RADIUS DELTA C1 30.30 22.50 77'09'13" C2 8.50 22.50 21"38'34" C3 35.34 22.50 go·oo'oo" C4 17.67 22.50 45·00'00" cs 8.06 22.50 20'31 '38" C6 36.08 22.50 91'53'19" CONSTRUCTION NOTES 0 PROTECT IN PLACE (ITEM AS NOTED) 0 ADJUST TO GRADE (ITEM AS NOTED) TABLE TANGENT SIZE 17.95 18" 4.30 18" 22.50 18" 9.32 18" 4.07 1 8" 23.25 18" 1. CONSTRUCT 3" AC OVER NATIVE MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 2. CONSTRUCT 3" AC OVER 3" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 3. CONSTRUCT 3.5" AC OVER 4" AB MINIMUM-FINAL SECTIONS TO BE BASED ON FINAL R-VALUE 4. CONSTRUCT 6" PCC OVER NATIVE 5. CONSTRUCT 6" CURB PER DETAIL A 6. CONSTRUCT 6" CURB AND GUTTER PER DETAIL B 7. CONSTRUCT PCC SIDEWALK PER DETAIL C 8. CONSTRUCT HANDICAP RAMP PER DETAIL D 9. CONSTRUCT HANDICAP RAMP PER DETAIL E 10. CONSTRUCT V-GUTTER PER DETAIL F 11. CONSTRUCT DRIVEWAY PER CITY OF CARLSBAD STD GS-12 12. CONSTRUCT RETAINING WALL PER SEPARATE PERMIT 13. CONSTRUCT 2' WIDE WALL DRAlN PER DETAIL G 14. CONSTRUCT 3' WIDE WALL DRAIN PER DETAIL G 15. CONSTRUCT 4" PVC BACK DRAIN PER DETAIL SHT 6 16. CONSTRUCT ROOF DRAIN PER DETAIL J 17. CONSTRUCT TRASH ENCLOSURE PER ARCHITECT'S PLAN AND CITY OF CARLSBAD STD GS-16 18. CONSTRUCT ENHANCED PAVING PER ARCHITECT'S PLAN 19. CONSTRUCT MONUMENT SIGN PER ARCHITECT'S PLAN 20. CONNECT ROOF DRAIN TO STORM DRAIN 21. CONSTRUCT V-GUTTER PER DETAIL H 22. CONSTRUCT ROOF DRAIN PER DETAIL J 23. CONSTRUCT SWALE PER DETAIL K 24. SIDEWALK PER SAN DIEGO REGIONAL STD G-7 W=4.5' SEE DWG NO. 404-3 25. CONSTRUCT MOW STRIP PER DETAIL M 30. REMOVE TREE 100. CONSTRUCT 6" PVC (SDR-35) 101. CONSTRUCT 8" PVC (SDR-35) 1 02. CONSTRUCT 12" PVC (SDR-35) 103. CONSTRUCT 18" RCP (D-2000) 1 04. CONSTRUCT 6" ROUND NDS GRATE (MODEL # 50) 105. CONSTRUCT GRATING CATCH BASIN PER APWA STD 304-2 W=3.0' 106. CONSTRUCT CURB OPENING CATCH BASIN PER APWA STD 300-2, W=3.5' 107. CONSTRUCT 4" NOS ATRIUM GRATE 108. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 332-1 109. CONSTRUCT JUNCTION STRUCTURE PER APWA STD 331-2 110. CONNECT TO EXISTING CATCH BASIN PER APWA STD 335-1 111. CONSTRUCT SQ;,,_,MQpEL PM~ .. Zfa---.---c------.__ K -,4~ -OONS. ··_T_RUe'f ... 3" P_ vc fs.·1'.Jf(:'.35) PER ..s~~s-D D .. -_ 2_ 7 --:;--I-·._ /I?,. C o.lS~ 1~T1o,J 57ZU~ r"'"IL ,f-/tJ'4 :int'?, • { .. /''·•···· r•···-,.. j~-.. -~ •, .. ,. ___ r--......__; "-<.,_ ••, ._,,, ~ •-, ,,,,•-"::-':"'-'V:'>-•,M<'Sill"·'°"""""' "·''"-"'•,.,.,c;:.7,.,~ "<,..,,,....,,,,_. I FINISHED SURFACE I I PROPOSED--. A: 18" RCP V1 PROPOSED EASEMENT --j 11-+-~II __ PROPOSED 8" WATER I I--PROPOSED EASEMENT t : PROPOSED 8" SEWER GRAPHIC SCALE 30 0 15 30 60 I -~ •. -r ! I I ( IN FEET ) 1 inch = 30 ft. PLANNING DEPARTMENT APPROVAL /AAuQ,,.,.~~q 1 DATI!: ifr1/t>3 IIICHAEL l. 1!111,Zi!D)l;ER, PLAN!IING llllll!CTOR Rl!COIIMEMIEIJ BY· Si\ IM -I'--. & V~tSI-\ Y ' (PIIINT !!all) 120 I "AS BUILT" d c. _t1_ .4-~-'6-ot/ ~<ftflS' EXP. ~-3t-~ ft> DATE l----+----+--------------+---+---1---+-----I I SH5EET I CITY OF CARLSBAD I SH~TS I ~==-===EN=G:::::IN=E=E=R=IN=G=D=E=PA=R=TM::::::::EN=T==::::::..====: ANJON GINEERING, !INC. 895 E. Yorba Undo Blv{J., Ste 202 "-'=::cJ Placentia, CA 92870 (714 )572-6800 FAX(714)572-6850 ------~---------- 1----1----t-----------------t----1---+---+----1 GRADING AND EROSION CONTROL PLANS FOR: DATE DA TE INITIAL DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL CARLSBAD OFFICE PARK APPROVED LLOYD B. HUBBS or 4,-& ~ #. J/4/~ CITY ENG17ER PE i:3ii89E:xPIREs 12 31 05 OWN BY: -!EL-0-~ PROJECT NO. CHKD BY:--':::~:-:';.::!:,!,_;--PIP 02-03 RVWO BY: ll ·-----------___ ! __ _ /•31; ~c3 DATE DRAWING NO. 404-3A I I I I I I I I I I I I I I I I RETAINING WALL A PROFILE .,,. .,,. .,,. .,,. .,,. .,,. .,,. STA: 2+16.12 ELEV: 215.67 .,,. .,,. .,,. STA: 1 +93.36 ELEV: 215.00 STA: 2+58.45 ELEV: 215.67 I ----I --------... -----------STA: 2+66.57 ELEV: 215.00 STA: 1+65.79 ELEV: 218.08 STA: 1+51.85 ELEV: 218.75 STA: 1+29.68 ELEV: 218.75 STA: 1+18.71 ELEV: 218.08 I ----~--, :;..cc..;;._:....c..c.=-'-'=.:....::.=c..._--,1------',/ / \L..L ____ --\ STA: 1+11 ELEV: 217.41 , -_ RETAINING WALL B PROFILE STA: 2+26.22 ELEV: 218.75 STA: 2+26.22 ELEV: 218.08 STA: 3+00 ELEV: 218.75 STA: 4+14.29 ELEV: 218.08 STA: 3+87.80 ELEV: 218.75 STA: 4+25.60 ELEV: 218.75 ----___ ---="-"+-EXISTING GRADE @ UP OF WJ\,LL GUTTER .,,. / ~ 1+73.22 ELEV: 214.34 '-, I ,J STA: 2+72.41 ELEV: 214.34 I / / / ""\. '\'-----------'.,,. ------ S::..:T'-"A:_1cc.+..:.;05:..:..6:..::8....:E=LEV=:....: c:.21;.:c6"-.75"---__,,........, / • , __. ..- / ...__ ----I 4-1 -PROPOSED GRADE@ / --/ STA: 1 +57.77 ELEV: 213.67 .,,. .,,. .,,. / ________ .,... __ ,,.. ,,,, I __ ..,.,,._,,,,- sTA:,,,,1 +42.99 ELEV: 213.00 -------------1 _.,,..,,. STA: 1+29.27 ELEV: 212.34 ------'-------'---"-'--..---.....,,...,.. STA: 1 +17.07 ELEV: 211.67 I . .,,. .,,. .,,. ::..::..::....:....:..:..:...:;:..:.....:=.:....::.:..:..:..::.:......---,1 ___________ ,.,,.. STA: 1 +05.75 ELEV: 211.00 ,. ,,,----------..---....- STA: 1 +00 ELEV: 210.33 .,,. .,,. / / .,,. / ----------- ---.----"--....C.....---"=----"---'- ( ,,.,.,.. __ ST_A:_2_+_74_.9_2_E_LEV_: _21_3_.67 -----+--PROPOSED GRADE @ LIP OF WALL GUTTER --.:::-- -_ ------------...__r---PROPOSED GRADE @ __ ----EXPOSED FACE STA: 2+74.92 ELEV: 211.00 STA: 2+ 13.34 ELEV: 210.34 I I .,,. .,,. STA: 1 + 72.66 ELEV: 209.67 ,/ STA: 1+00 ELEV: 207.00 / / / I / / I / STA: 1+45.17 ELEV: 209.00 I STA: 1+31.91 ELEV: 208.34 STA: 1+20.10 ELEV: 207.67 STA: 1+10.05 ELEV: 207.00 STA: 1 +00 ELEV: 215.42 I I I I I I I ----I EXPOSED FACE OF WALL I I I I /---------------I _____________ / ',...._ /,_..__S_~_-_4+_2_5_.6D_ELEV_:_2_14_.08_ --------------------....__ I -------..... ------'...._ I -------STA: 3+61.20 ELEV: 212.75 I ',...._...._ / ,.....,.. __ S~TA:_·_4_+=20....:,8~6....:E=LEV~=-2~1~2-_75 I STA: 1+62.48 ELEV: 212.08 STA: 3+74.40 ELEV: 212.08 I ----- "" STA: 1 +00 ELEV: 212.08 STA: 2+99.40 ELEV: 212.75 STA: 3+87.80 ELEV: 211.41 STA: 4+ 17.44 ELEV: 211.41 RETAINING WALL C PROFILE RETAINING WALL PROFILE & DETAIL SHEET STA: 1 +45.40 ELEV: 213.67 STA: 1+58.72 ELEV: 213.67 Bin MAS W/#5@16in o;c ___ ,__----,...-, SOLID GROUT -------- #4@24 12in MAS W/#6@8in 0/C • • SOLID GROUT-------- (RETAINING WALLS PER SEPARATE PERMIT, SHOWN FOR REFERENCE ONLY) 2' CAP 7'_4• V BACK DRAIN PER DETAIL THIS SHEET -3• / /----" 2'-8" Bin MAS W/#4®24in 0/C SOLID GROUT #4@24 2' CAP • • r--- 4'-0" -2 3/4' 6'-Q" STA: 1+29.88 ELEV: 213.01 STA: 1+72.32 ELEV: 213.01 ---~ _.. ---" STA: 1+14.37 ELEV: 212.34 I RETAINING WALL D PROFILE I ---" STA: 1 +02.80 ELEV: 211.67 _.-.,,.,., '--STA: 1 + 79.02 ELEV: 211.67 STA: 1+31.38 ELEV: 212.60 ---------.--~ -,..,,. ./ ', I ,., STA: 1 +85.81 ELEV: 211.01 ---" L---,-.....c.cc.:..._.;..c.;:=..c...=:~-=-~ \ <:: ', I EX GRADE ---t----,._____ '-. STA: 1 +BB.19 ELEV: 210.34 STA: 1+11.10 ELEV: 212.60 PROPOSED GRADE @ ---:c..---_ '- EXPOSED FACE ---------=---=---'-. +--PROPOSED FS GRADE ---- - ---~ --=------:i: S;:..;T:..::.A:_l_+.:...00'-='EL=EV~=-=2-11-·9_4_-.-_ __,I _,.. ,,,--~-PROPOSED FS GRADE / STA: 1 +02.80 ELEV: 209.00 STA: 1 +21.58 ELEV: 208.33 I STA: 1 +88.19 ELEV: 20.!l.33 2• CAP Bin MAS W/#4@24in 0/C SOLID GROUT --t---~I - #4@24 -i-2 3/4" 3' -6" 4' -0" ,,,--I--BACK DRAIN PER STA: 1 +00 ELEV: 206.60 / , ---/ --------"+--EX GRADE - v-PROPOSED GRADE -------___,;t_ @ EXPOSED FACE OF WALL STA: 1 +31.38 ELEV: 208.60 / / NATIVE EARTH ~ mM I Jl;;'L il ,__N-=m!rr: I In 2·MAX -~"rflln I :::'!IT-;[ - 1 CF/LF PEA GRAVEL WRAPPED IN MARAFI FILTER FABRIC-140N t----+------lf------lf I I I I I t----+------lf------111 #5@16.in I • I [@HEEL1 '\ ✓FlLLET 12in MAS W/#5@16in o/c_ \. ----+-I/ SOLID GROUT ~ ,:.. I/ F.G.~ ,--------------✓ DETAIL THIS SHEETW·· ALL BACK DRAIN & BACKFILL DETAIL g~~L Df~~ ri:ET ,-.. , -... "" -.. ·t-----='1--1i #5@r N T S 1'-o• I @ HE~L • ' • l I '--/ / 3• • • • 10· l 3 1/2" - 3•-l- #4@24.in 1 '-6' 1-------------5'-10·---------1 INTERIOR ON-SITE 7FT-41N RETAINING WALL SPECIAL INSPECTION REQUIRED FOR 12" BLOCK AND REINFORCEMENT N.T.S. SEE ALSO SHT 7 FOR ADDITIONAL WALL STRUCTURAL SECTIONS ' • • • i---2'-Qu __ _, 10·-l-8"-1-----2·-2·----+-- 1--------3'-8"------l INTERIOR ON-SITE 6FT RETAINING WALL N.T.S. 3• t 10· 3 1/2" - 1'-0" l +--2· EMBED,, I J "-, __ / I t-t----,...-~-~-+- 1 3• I • f 10· 10· I • • • I 3 1/2'] I e· I 1------2·-s·----1 INTERIOR ON-SITE 4FT RETAINING WALL N.T.S. •• r~ ---. . . !Y, J.1"4i' . ~ 95 E. Yorba Lind: vd., S!e 202 = Placentia, CA 92870 (714)572-6800 FAX(714)572-6850 PLANNING DEPARTMENT APPROVAL 1MuR.a%.,,O-Oe..., DATE: l/z-rfa$ IIICBAEL J. l!OLZlllU1ilR, PLINDIG DlllllC'lOR DP"''""'"""'Pn BY· <; ;,._ \'N\t, &\JR E: s H '1 """""""'""" . (l>IUTNm) "AS BU IL T" t'"" U,RtP- ~lEWED BYO: ! '"" 0 INSPECTOR / I SH6EET I CITY OF CARLSBAD I SH~TS I 1------+--+----------------+-----+---1----+----1 ENGINEERING DEPARTMENT l----+--+---------------+----+--1----+----I 1----+--+---------------+----+--t----+----1 GRADING AND EROSION CONTROL PLANS FOR: CARl.SBAD OFFICE PARK APPROVED LLOYD B. HUBBS /1 Y !-----+--+---------------+----+--t----+----1 ,t.&tr:iitd~'~!ie:;f..{.-1:::.~""~~-~-:f,C_ ______ t·?p •e,3 CITY ENwi'ER PE#n88i EXPIRES 12/31 /05 DA TE DATE l~I "IAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL 01HER APPROVAL CITY APPR-OVAL DWN BY: ~ PROJECT NO. DRAWING NO. 2~~ ~~~ Riif-~P_I_P __ O_2_ -_O_3~~4_0_4_-_3_A~· _____ _j -------------- RETAINING WALL. PROFILE SHEET (RETAINING WALLS PER SEPARATE PERMIT, SHOWN FOR REFERENCE ONLY) STA: 6+90.15 ELEY: 207.87 STA: 7+05.01 ELEY: 207.87 RETAINING WALL G PROFILE STA: 1 +03.09 ELEV: 212.95 STA: 1+00 ELEV: 212.29 PROPOSED GRADE \ PROPOSED GRADE --,i-; ,,.- '--/ STA: 1 +00 ELEV: 208.48 STA: 1 +02.84 ELEV: 207.81 PROFllE SCALES: HOR 1"=20' VER 1" =2' / / / STA: 1+21.45 ELEV: 212.95 / STA: 1 +35.34 ELEV: 212.29 STA: 1 +37 ELEV: 211.62 EXISTING GRADE STA: 1+37 ELEV: 209.15 STA: 1 +32.60 ELEV: 208.48 STA: 1+19.20 ELEV: 207.81 RETAINING WALL E PROFILE STA: 1 +00 ELEV: 199.20 STA: 1 + 24.44 ELEV: 199.20 STA: 1 +42.37 ELEV: 198.53 STA: 1 +56.55 ELEV: 197.87 RETAINING WALL H PROFILE STA: 1 +24.23 ELEV: 215.49 STA: 1+15.59 ELEV: 214.82 STA: 1 +oo ELEV: 214. 16 PROPOSED GRADE_,____ PROPOSED GRADE STA: 1+00 ELEV: 210.15 STA: 1 + 12.98 ELEV: 209.48 STA: 1 +25.95 ELEV: 208.82 SEE SHEET 6 FOR RETAINING WALL STRUCTURAL SECTION AND BACKFILL STA: 1 +38.01 ELEV: 215.49 STA: 1 +39.84 ELEV: 212.82 STA: 1+41.17 ELEV: 212.16 EXISTING GRADE STA: 1 +41.17 ELEV: 208.82 w z -_J I u r- <( 2 00 (j) • EXISTING GRADE 3' LEFT OF EXPOSED FACE OF WALL STA: 1 +70.74 ELEV: 197.20 (D (j) STA: 1 +00 ELEV: 195.20 STA: 1+12.47 ELEV: 194.53 STA: 1 +24.94 ELEV: 193.87 STA: 1 +37.22 ELEV: 193.20 STA: 1 +49.69 ELEV: 192.53 STA: 1 +62.30 ELEV: 191.87 STA: 1+75.05 ELEV: 191.20 STA: 1+83.23 ELEV: 196.53 STA: 1 +94.57 ELEV: 195.87 STA: 2+05.92 ELEV: 195.20 STA: 2+17.09 ELEV: 194.53 STA: 2+29.86 ELEV: 193.87 STA: 2+47.00 ELEV: 193.20 STA: 2+63.88 ELEV: 192.53 STA: 2+81.03 ELEV: 191.87 STA: 2+97.80 ELEV: 191.20 + t') STA: 6+79.83 ELEV: 207.20 RETAINING WALL NOTES STA: 6+69.66 ELEV: 206.53 / /"' / '- / '- STA: 7 +08 ELEV: 207 .20 WALL CONSTRUCTION SPECIFICATIONS RETAINING WALL E PROFILE STA: 6+61.75 ELEV: 205.87 / / / / / / 1. 2" CEMENT MORTAR CAP REQUIRED ON FINISHED TOP OF ALL RETAINING WALLS STA: 6+54.29 ELEV: 205.20 / / / / / 2. 3. 4. 5. 6. 7. 8. 9. 10 11 1 2 13 5 0 _J w (D w w (/) WEEP HOLES -OMIT GROUT FROM VERTICAL JOINT IN FIRST COURSE ABOVE PROPOSED FINISHED GRADE LINE AT 32" CENTERS CONCRETE FOR FOOTINGS SHALL BE 650-C-4000 OR 650-C-4000P. ALL SPLICES SHALL BE LAPPED A MINIMUM OF 40 DIAMETERS NO SPLICES SHALL BE ALLOWED IN VERTICAL BARS EXCEPT AS SHOWN ON THE DETAILS VERTICAL CORES CONTAINING STEEL SHALL BE FILLED SOLID WITH GROUT AND THOROUGHLY RODDED. ALL CORES SHALL BE FILLED SOLID. MASONRY UNITS SHALL BE MADE WITH SAND-GRAVEL AGGREGATE AND SHALL CONFORM TO ASTM C-90 FOR GRADE N-1 UNITS G.ROUT FOR SPACES OF LESS THAN 4" CLEAR SHALL BE 1 PART PORTLAND CEMENT AND 2-1/4 TO 3 PARTS SAND. EXPANSION JOINTS SHALL BE PLACED AT 40'-0" CENTER TO CENTER 1 / 4" PREMOLDED EXPANSION JOINT FILLER REBAR SHALL BE GRADE 60 TOE OF FOOTING SHALL BE POURED AGAINST UNDISTURBED SOILS UNLESS OTHERWISE DIRECTED BY THE ENGINEER. STA: 6+46.94 ELEV: 204.53 STA: 6+39.48 ELEV: 203.87 / STA: 6+31.72 ELEV: 203.20 / STA: 6+24.07 ELEV: 202.53 STA: 6+ 16.31 ELEV: 201.87 / / / / / / / STA: 6+D8.55 ELEV: 201.20 / STA: 6+00.90 ELEV: 200.53 STA: 5+93.14 ELEV: 199.87 STA: 5+85.40 ELEV: 199.20 STA: 5+77.78 ELEV: 198.53 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA: 7+08 ELEV: 204.53 / / STA: 7 +05.51 ELEV: 203.87 STA: 6+97.83 ELEV: 203.20 STA: 6+90.04 ELEV: 202.53 STA: 6+82.24 ELEV: 201.87 STA: 6+74.57 ELEV: 201.20 STA: 6+66.77 ELEV: 200.53 STA: 6+58.97 ELEV: 199.87 STA: 6+51.28 ELEV: 198.53 REFER TO APWA STD 618-0 AND SOILS REPORT FOR ADDITIONAL NOTES STA: 5+70,04 ELEV: 197.87 / / / / / / STA: 6+35.67 ELEV: 197 .87 EXISTING GRADE 3' LEFT OF EXPOS ED FACE OF WALL STA: 5+62.30 ELEV: 197.20 STA: 5+55.83 ELEV: 196.53 STA: 5+49.98 ELEV: 195.87 / / / / / / / / / / / / / / / STA: 6+27.99 ELEV: 197.20 STA: 6+20.18 ELEV: 196.53 STA: 6+ 12.38 ELEV: 195.87 / / STA: 5+44.12 ELEV: 195.20 STA: 5+38.35 ELEV: 194.53 STA: 5+32.49 ELEV: 193.87 STA: 5+26.41 ELEV: 193.20 STA: 5+ 19.52 ELEV: 192.53 / STA: 5+12.53 ELEV: 191.87 / / / / / / / / / / / / / / / / / / / / / / / / / STA: 6+04.69 ELEV: 195.20 STA: 5+96.88 ELEV: 193.87 STA: 5+81.39 ELEV: 193.20 STA: 5+73.59 ELEV: 192.53 STA: 5+65.78 ELEV: 191.87 2" CAP •• STA: 5+05.48 ELEV: 191.20 / / / / / / / / STA: 5+5!!.09 ELEV: 191.20 Bin MAS w//f4®241n o/c STA: 4+98.32 ELEV: 190.53 STA: 4+91.22 ELEV: 189.87 STA: 4+82. 78 ELEV: 189.20 4+ 73.64 ELEV: 188.53 / / / / / / / / / / / / / / / / / / / / / / / / STA: 5+50.29 ELEV: 190.53 / STA: 5+42.49 ELEV: 189.87 STA: 5+34.80 ELEV: 189.20 STA: 5+26.99 ELEV: 188.53 STA: 4+64.11 ELEV: 187.87 / / / / STA: 5+19.19 ELEV: 187.87 STA: 4+64.11 ELEV: 187.20 -·-·-· -·--- ..._ ..._ ------ ...L / / / / / / / / / / / / / / / STA: 5+11.50 ELEV: 187.20 STA: 5+03.70 ELEV: 186.53 STA: 4+95..89 ELEV: 185.87 _______________ ,....,.,. STA: 4+88.20 ELEV: 185.20 PROPOSED GRADE@ BACK OF PROPOSED 5' SIDEWALK STA: 4+80.40 ELEV: 184.53 STA: 4+72.59 ELEV: 18.3.B7 STA: 4+64. 11 ELEV: 183.20 PROFILE SCA! FS· HOR 1"=20' \IER 1• =2' SOUD GROUT-1--I #4®24 2 3/4" / ' I I #5@1i6.in I @ HEJEL / 3• • • • -, • L..-...J-1.. 6" _ I 6"--J-1'-2" 2'-2"' PERIMETER 3'-6" 4"-0" 10" STA: 1 +87.99 ELEV: 190.53 STA: 3+14.26 ELEV: 190.53 STA: 2+00.93 ELEV: 189.87 STA: 3+30.98 ELEV: 189.87 • • Bin MAS W/#4@24in 0/C SOLID GROUT --.J----t--1 4'-0" 2 3/4" #4@24 FlLLET 6'-0" 3" / " 2' -o" 2" EMBED #5~16. @ EE / 2" 3• • t I 10 3 1/2" 1'-0" ._____.J_ I 2'-4" f--10•-.. ___ :;__ __ ..-j 3'-6" 1------3'-8"'-----l STA: 2+13.67 ELEV: 189.20 STA: 2+26.61 ELEV: 188.53 STA: 2+40.76 ELEV: 187.87 ..._ ..._ STA: 2+57.40 ELEV: 187.20 ..._ ..._ - STA: 2+ 74.29 ELEV: 186.53 STA: 2+91.18 ELEV: 185.87 STA: 3+07.82 ELEV: 185.20 BACK DRAINS PER DETAJL SHEET 6 STA: 3+47.63 ELEV: 189.20 STA: 3+ 71.98 ELEV: 188.53 PROPOSED GRADE@ BACK OF PROPOSED 5' SIDEWALK STA: 3+96.98 ELEV: 183.20 3+96.98 ELEV: 187.87 . .._,_ ___ . __ _ ----- ..._ -------- -----------------✓ w w 00 z -(j) _J FRofolr ~ ~11!1> ~---"ol,.....,..Qi.. 1514 5'300(12.) __ ..,,GCOU=:..::-::..::U:::111::;:£:..,, '---=--<11,00,wun(l' -0") ; 'I (D u 0 (D <( PERIMETER 6FT RETAINING WALL N.T.S. SEE ALSO SHT 6 FOR ON-SITE WALLS STRUCTURAL SECTIONS D\1111\(1 /4") PRt!MOL1>51> fX'°AtlSION JO RUM Ill() T TO StAI.E f5M(l+)l!00{1Z) ur LI I 0) r-t <( t') 2 w w (/) /f4 1 '-0" TOT. 6 #2-8 TOT. 4 I A A A ~ '-----/ / ......__ ----------R ET Al NIN G WALL UTILl1Y OPENING MAX SlZE OF OPENING (A) = 12" MAX SPACING 8' O.C. 4FT RETAINING WALL N.T.S. SEE ALSO SHT 6 FOR ON-SITE INTERIOR WALLS STRUCTURAL SECTIONS 2-/f8xA+4' -0" TOT. 4 (OMIT FOR "A" LESS THAN 12") PLANNING DEPARTMENT APPROVAL ~iOOb DATE: I /z;"t/03 (SIG'NIII) IIIC81EL 1. HIJI,Z!,QJ,J;ER, JJtANNlliG DIRl!CTOK l!l!COIIIIENDED BY: S,1>-.\Nlr", (y,\JK6S14'f (PIIIN'f NlllE) . JNEERJNGINC. 95 E. Yorba Linda Blvd., Ste 202 Placentia, CA 92870 (714)572-6800 FAX(714)572-6850 "AS BUILT" AP-s~t/. EXP 3 -31-l>l,. DATE 1---~l-----+------------l----l---+---1----II SH7EET I CITY OF CARLSBAD I SHE8ETS I '.==:::=...:::::=:::=EN::::G::::IN::::E::E:::R::::IN:::::G::::::::D:::E::::::PA::::R:::::T::::M:::EN::::T:::::::=='...'::===:: 1-----<l----+-----------------11----+---+----1----1 GRADING AND EROSION CON'rROL PLANS FOR: ,CARLSBAD OFFICE PARK APPROVEID LLOYD B. HUBBS dY ~N~fifE~Prr~PIRES 12 31 05 ,-i"i~J DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DAlE INl11AL DAlE INl11AL OWN BY: '.~ PROJECT NO. :• DRAWING NO. 1-0.;....TH_ERc.../\....JP'-PR-ov-AL-+-c-'-',n'-=--AP.._PRc..:.o-"-vA-=L-1 ~~~ ~~'.~ PIP 02-. 03 : 404-3A . . I I I s'\')j\,f:,;;. ·:.-.,.-,Jl;t;. -"~ '" ,.-; ... : ~~ ! '• f !' · .. ' ' I . I q I: I I ..... __ __ -- I , I : I I I 42 ... ;, : . . f .. : 1-A'lt-+--t-+tl ' -. : ': · r,..·•;h·'_,.._ l·'.d"I . : ' . • 42 ~A".F~='"'='~~~~=-~~~=BZ\ \\ /\\ \ \ ,•·-:::;=::~===;=~:•.1' --=,-=,;:~ <·1 ---· .~ -~3!35(/ b/ ~I J~ ~~k·,~~/ 42 l -..,~fllii•-p--==-==ai !!.!.!!==-=-==-;in H-1--H d'!q.~; 1',:,,;;;,' ----------------------- I ' I' i l I . 2. " I 3. I ~ 4. 5. 0 EROSION CONTROL NOTE IN CASE EMERGENCY WORK IS REOUIRED,CONTACT RICHARDT. BOURESTON AT (949) 387-4665 EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE DE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS . TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMl/>!ENT. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODljlED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL D VICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTE~ EACH RUN-OFF PRODUCING RAINFALL. I I 6. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CON~ROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETEt GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE ECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDIT I ON. , ~l "~1 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPkovED GRADING PLAN SHALL BE INCORPORATED HEREON. I I 8 GRADED AREAS AROUND THE PROJECT PERIMETER MUST ORAi AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. I I 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN LACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5/ DAY RAIN PROBAB!LITYI FORECAST EXCEEDS FORTY PERCENT {40%}. SILT AND OTHER DEBRIS SHALL BE REMovtD AFTER EACH RAINFALL. l ~. ~I " I I I I " + I I I I . I !1 I I I I T I I I I!! I I " I I l I .JI I I I 1 -, I I I I . l I I I " I IO. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH k1N/MUM AGGREGRATE. II. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PJoVIDE EFFECTIVE COVERAGE OF GRADED SLOPES {90% COVERAGE) PRIOR TO NOVEMBER •15, THE SLOPES SHALL /3E STA/31L fZED BY PUNCH STRAW INSTALLED IN ACCORDANC!E WI TH SECTION 35. 023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, STATE OF CALIFORNIA. I TEMPORARY EROSION CONT~OL PLANTING AND IRRIGATI(jN ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING hND IRRIGATION INSTALLED AND MAINTAINED AS REOUIRED IN SECTION 212 0 THE STANDARD SPECIFICATIONS AND THE FOLLOWING, A. HYDROSEED!NG SHALL BE APPLIED TO, SHALL BE I. ALL SLOPES THAT ARE GRADED 6, I (HORIZONTAL TO VERTICAL/ OR STEEPER WHEN THEY ARE, a. THREE FEET OR MORE IN HEIGHT AND ADJAC NT TO A PUBLIC WALL OR STREET. . 'l b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED FLATTER THAN 6, I WHEN ANY OF HE FOLLOWING CONDITIONS EX/SL I a. NOT SCHEDULED FOR IMPROVEMENTS (CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREATIO DIRECTOR AS HIGHLY VISIBLE TO THE PUBLIC. c. HAVE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREATMENT. B. HYDROSEEDED AREAS SHALL BE IRRIGATED IN ACCORDAN E WITH THE FOLLOWING CRITERIA, ' I. ALL SLOPES THAT ARE GRADED 6, I OR STEEPER A~D THAT ARE, a. THREE TO EIGHT FEET IN HEIGHT SHALL BEi/RR/GATED BY HAND WATERING FROM QUICK COUPLERS/HOSE BfBSIOR A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS P*OVIDfNG 100% COVERAGE. b. GREATER THAN B FEET IN HEIGHT SHALL /3E 1WATERED BY A CONVENTION- AL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. ~- 2. AREAS SLOPED LESS THAN 6, f SHALL BE IRRIGATE AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEDfNG. THE DEVELOP R SHALL SUBMIT A PROPOSED SCHEME TO PROVIDE IRRIGATION TO THE!CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUM~ERS, TYPES AND COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM. l 3. IRRIGATION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOil AT THE OPTIMUM LEVEL FOR THE GROWTH OF THE HYDROSEE ED GROWTH. C. HYDROSEEDfNG MIX SHALL CONSIST OF ALL OF THE FOL~OWfNG, D. I. SEED MIX SHALL CONSIST OF NO LESS THAN, , 3. a. 20 lbs. PER ACRE OF ROSE CLOVER I b. 20 lbs. PER ACRE OF ZORRO FESCUE I c. 3 lbs. PER ACRE OF E SCHOOL CIA CALfFORNICA d. 4 lbs. PER ACRE OF ACHILLEA MILLEFOLIA j •· 3 lbs. PER ACRE OF ALYSSUM {CARPET OF SNOW/ f. 1/2 lb. PER ACRE OF DIMORPHOLECA I g. ITEMS c,d,e, AND I OF THIS SUBSECTION "'AY BE OMITTED ON LOCATIONS WHERE THE AREA BEING HYDROSEGDED IS NOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER 'BY DRILLING OR BROADCASTING BEFORE HYDROSEEDING. ~- i. ALL SEED MATERIALS SHALL BE TRANSPORT£ TO THE JOBS/TE IN UNOPENED CONTAINERS WITH THE CAL/FORNI DEPARTMENT OF FOOD AND AGRICULTURE CERTIFICATION TAG ATTA HED TO, OR PRINTED ON SAID CONTAINERS. I ). NON-PHYTO-TOXIC WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRAdTOR. TYPE I MULCH APPLIED AT THE RATE OF NO LESSiTHAN 2000 lbs PER ACRE. TYPE 6 MULCH {STRAW/ MAY BE SUBSTITUTED, AL OR PART, FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHEN TRAW IS USED IT MUST BE ANCHORED TO THE SLOPE BY MECHANICALLY PUNCH/NG NO LESS THAN 50% OF THE STRAW INTO THE SOIL. I FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE kuLFATE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RATE OF 500 lbs. PER ACRE. AREAS TO BE HYDROSEEDED SHALL BE PREPARED PR I OR TO HYDROS EEO f NG BY, I. ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A COMBINATION OF, a. TRACK WALKING SLOPES STEEPER THAN 6, f , b. HARROWING AREAS 6, I OR FLATTER THAT AREf SUFFICIENTLY FRIABLE. C. RIPPING AREAS THAT WILL NOT BREAK UP us!/NG ITEMS a OR b ABOVE. ------., -----, _____ , "'~..----,•. -----, -----' _____ , _____ , -----,•, ---+--+ CONDITIONING THE SOILS SO THAT IT IS SUITABL~ FOR PLANTING BY, ----------- E. 2. o. ADJUSTING THE SURFACE SOil MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED. THE ADDITION OF SOil AMENDMENTS, PH ADJ~STMENT, LEACHING OR COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR GROWTH. b. HYDROSEEDED AREAS SHALL BE MAINTAINED TO PROVIDE 1 VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE HYDROSEEDfNG IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED. EROSION CONSTRUCTION NOTE MAX HEIGHT OF CHECK DAM : 3' PROVIDE AN EXTRA ROW OF GRAVEL BAGS FOR EVERY ROW OF GRAVEL BAGS 3 GRAVEL BAGS HIGH G CONSTRUCT GRAVEL BAG BARRIER, PER DETAIL 'K' HEREON. @ CONSTRUCT CHECKDAM PER DETAIL 'J' HEREON. ** @ CONSTRUCT STABILIZED CONSTRUCTION ENTRANCE PER DETAIL 'L' HEREON 4" DIA PVC C 1 O' O.C. SECTION SECTION 2' 8' 2' I I ' ' I I I I J. I I I I I I I I I I I I I I I I I I I I I I I 10' oc DETAIL 'J' -CHECKDAM WOVEN FABRIC GRAVEL BAG MIN. WEIGHT 40 LBS. 2 BAG HEIGHT -UNLESS NOTED OTHERWISE 1. :-:-111:-.. 111 ... 111-.. 111 ... 111 .. 111; .. 111:-~ NOTES: FRONT YIEW 1. GRAVEL BAG MATERIAL TO BE GEOTEXTILE FABRIC. 2. REMOVE SEDIMENT WHEN DEPTH EXCEEDS 1 /2 OF GRAVEL BAG HEIGHT. DETAIL 'K' -GRAVEL BAG BARRIER GINEERINGINC. B95 E. Yorba Li.ndo Blvdd Ste 202 Placentia, CA 92B7 (714)572-6800 FAX(714)572-6850 SO'MIN. ----=TTT· = "m--m 1T1:-~--,--8" MIN. -I PROFILE PUBLIC R!GHT- OF-WAY EXISTING GROUND _l_ /4'MIN. T DETAIL 'L' ENTRANCE - £1.M! PUBLIC RI HT-OF-WAY PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT-OF- WAY STABILIZED CONSTRUCTION GRAPHIC SCALE ( IN FEET ) 1 Inch = 30 It. PLANNING DEPARTMENT APPROVAL "AS BUILT" WwP,,.o~Wo , DATE: 1 /t'f/oJ "-1-~t./ IIICIUEL J. ~nLZMIW!R, PLANIIIIIG DIRICl'OR ,3 3( (., EXP --lJ DATE ~ (SIGKZll~½ DATI: \ /21/0~ t--'~--BY-,-----------t RICOIIIIINDBD BY: $/',IN,~ QuRE' SI-I½' (PRINT NAIii!) 1---t----+-------------jf----t---+--+---I I SHBEET I CITY OF CARLSBAD I SH8TS I ~=::::'...==:::E:::N:::G:::IN:::EE::R:::IN:::G:::::::D:::EP::::A:::R::::TM:::E::N:::T==~==~ t---i----i-----------------1-----1---1---+----t GRADING AND EROSION CONTROL PLANS FOR: DATE INITIAL DA TE INITIAL ENGINEER OF· WORK REVISION DESCRIPTION OlliER APPROVAL CITY APPROVAL CARI.SBAD OFFICE PARK APPROVED LLOYD B. HUBBS (lY _,q. & .. ~'fff uY~ I • -,, .... -, CITY ENGIER PE 3889EXPIRES 12 31 05 DATE OWN BY: CHKD BY: RVWD BY: PROJECT NO. PIP 02-03 DRAWING NO. 404-3A / 021803 i r