Loading...
HomeMy WebLinkAboutCT 14-08; LOT 9 DEVELOPMENT WESTIN HOTEL AND TIMESHARE; FINAL SOILS REPORT; 2020-01-27Test Elevation/ Location/ No. Test Date Depth Ft. Station AC on drive E. of Villa 80; N. end of 861 2/19/19 FG drive. AC on drive E. of Villa 80; center of 862 2/19/19 FG drive. AC on drive E. of Villa 80; NW parking 863 2/19/19 FG lot stall. AC on drive E. of Villa 80; entrance 864 2/19/19 FG to garage. ' AC on drive E. of Villa 80; S. end of 865 2/19/19 FG drive. AC on drive E. of Villa 80; NE parking 866 2/19/19 FG lot stall. Soil Type 580 580 580 580 580 580 DENSITY TEST RESULTS TABLE 2 Max. Dry Moisture Density Content (pcf) (%) 146.8 6.5 146.8 6.6 146.8 7.2 146.8 7.1 146.8 7.3 146.8 7.1 Dry Density (pcf) 138.6 138.8 139.2 141.0 141.3 141.5 Relative MTGL Project No. 1916810 Log No. 20-1026 Required Compaction Compaction (%) (%) 95 95 95 95 95 95 96 95 96 95 97 95 Test Elevation/ Location/ Soil No. Test Date Depth Ft. Station Type AC on circle drive S. of Villa 80; S. end of driveway on circle 867 2/19/19 FG drive. 580 AC on circle drive S. of Villa 80; at entrance to garage off circle 868 2/19/19 FG drive. 580 AC on circle drive S. of Villa 80; center of driveway on circle drive, S side of 869 2/19/19 FG driveway. 580 AC on circle drive S. of Villa 80; S. end of driveway on circle drive, N. side of 870 2/19/19 FG driveway. 580 DENSITY TEST RESULTS TABLE 2 Max. Dry Moisture Density Content (pcf) (%) 146.8 6.9 146.8 7.2 146.8 7.2 146.8 6.9 Dry Density (pcf) 141.1 141.0 139.8 140.5 Relative MTGL Project No. 1916B10 Log No. 20-1026 Required Compaction Compaction (%) (%) 96 95 96 95 95 95 96 95 Test Elevation/ Location/ No. Test Date Depth Ft. Station AC on circle drive S. of Villa 80; center of driveway on circle drive, S. side of 871 2/19/19 FG driveway. AC on circle drive S. of Villa 80; N. end of driveway on circle drive, N. side of 872 2/19/19 FG driveway. Retaining wall at S. end of Villa 80; nearW. end,S side of 873 3/4/19 FG-2' wall. Retaining wall at S. end of Villa 80; near W. end, east of test 874 3/4/19 FG-1' #873 Soil Type 580 580 6 6 DENSITY TEST RESULTS TABLE 2 Max. Dry Moisture Density Content (pcf) (%) 146.6 7.0 148.8 6.8 124.5 11.5 124.5 10.2 Dry Density (pcf) 141.0 139.8 115.3 114.1 Relative MTGL Project No. 1916B10 Log No. 20-1026 Required Compaction Compaction (%) (%) 96 95 95 95 93 90 92 90 Test Elevation/ Location/ No. Test Date Depth Ft. Station Retaining wall at S. end of Villa 80; near center, east of 875 3/4/19 FG test #874. Retaining wall at S. end of Villa 80; near center, of south 876 3/4/19 FG-3' wall. Retaining wall at S. end of Villa 80; east of 877 3/4/19 FG-5' test #876. Retaining wall backfill 5. of Villa 80; toward W.of 878 3/5/19 FG-5' center. Retaining wall backfill S. of Villa 80; toward E. 879 3/5/19 FG-2.5' end. Soil Type 6 6 6 6 6 DENSITY TEST RESULTS TABLE 2 Max. Dry Moisture Density Content (pcf) (%) 124.5 10.6 124.5 10.8 124.5 11.3 124.5 12.6 124.5 12.1 Dry Density (pcf) 117.9 114.8 114.2 121.0 119.3 Relative MTGL Project No. 1916B10 Log No. 20-1026 Required Compaction Compaction (%) (%) 95 90 92 90 92 90 97 90 96 90 Test Elevation/ Location/ Soil No. Test Date Depth Ft. Station Type Retaining wall backfill S. of Villa 80; E.of 880 3/5/19 FG-4' test #878. 6 Retaining wall backfill S. of Villa 80; just W. of test 881 3/5/19 FG-2' #879. 6 DENSITY TEST RESULTS TABLE Z Max. Dry Moisture Density Content (pd) (%) 124.5 11.8 124.5 11.7 Dry Density (pd) 118.8 119.5 Relative MTGL Project No. 1916B10 Log No. 20-1026 Required Compaction Compaction (%) (%) 95 90 96 90