HomeMy WebLinkAboutDWG 412-7; PKS 03-08; CHASE FIELD SPORTS LIGHTING ELECTRICAL UPGRADES; ET1-E5. g H <I) N •rl "' Cl 0 "' .,, m "' c- rl rl rl "' 0 0 N ..___ '-" ..___ 0 . rl eALLFIELD UQHTING QENERAL hlOTES-EXISTING Sll'E A. SECURE EXISTING PLANS FROM CITY (ELECTRICAL, AND THE UTILITIES, IRRIGATION, ETC,) AVOID EXISTING UNDERGROUND ELECTRICAL AND SPRINKLER SYSTEMS WHERE POSSIBLE. REPAIR All EXISTING SYSTEMS DAMAGED BY CONSTRUCTION TO CITY'S REQUIREMENT. B. STAKE OUT EXACT LOCATION OF POLES AND CONDUIT ROUTING WITH CITY PRIOR TO ANY WORK. ANY LOCATION NOT WITHIN 24" OF LOCATION SHOWN ON PLAN SHALL BE NOTIFIED TO ENGINEER AND LIGHTING MANUFACTURER IMMEDIATELY AND PRIOR TO CONSTRUCTION. CITY TO ACCEPT LOCATIONS OF POLES AFTER CITY SITE REVIEW OF POLE LOCATIONS. C. CONTRACTOR SHALL CAREFULLY REMOVE, STORE, AND REPLACE EXISTING SOD AFTER INSTAUATION IS COMPLETE. ANY EXISTING IRRIGATION PIPING OR OTHER UTILITIES WHICH ARE DAMAGED OR REQUIRE RELOCATION DURING CONSTRUCTION SHALL BE REPLACED TO THE SATISFACTION OF THE CITY. D. TRENCHING NOTES, 1) TRENCH AROUND PLAYING FIELDS AND NOT ACROSS INTO OUTFIELD PLAYING AREAS EXCEPT AS INDICATED OR UNAVOIDABLE. 2) CONTRACTOR SHALL VERIFY WITH CITY EXACT TYPE AND WEIGHT OF CONCRETE TRUCKS TO BE USED ON ALL TURF AREAS. DO NOT USE TRUCKS WITH WEIGHT NOT APPROVED BY THE CITY. J) RUTS WHICH ARE MADE WITH CONCRETE TRUCKS NEED TO BE TOP DRESSED WITH SANDY LOAM SOIL t.tlXED WITH A MULCH AND SEEDED WITH COMMON BERMUDA SOD-OVERSEEDED W. PERENNIAL RYE (OR AS REQUIRED BY CITY), 4) WHERE TRENCHING SOIL HAS SETTLED, IT. WILL REQUIRE TOP SOIL TO BE ADDED, OVER SEEDING, AND TOP DRESSED WITH MULCH. E. CONTRACTOR TO VISIT EXISTING SITE AND VERIFY ALL EXISTING CONDITIONS. F. (CITY TO OBTAIN PERMITS, CONTRACTOR RESPONSIBLE FOR OBTAINING INSPECTIONS) G. VERIFY ALL POLE AND OUTLET LOCATIONS WITH THE CITY BEFORE COMMENCING WORK. POLE AND OUTLET LOCATIONS AND CONDUIT RUNS ARE SHOWN DW:RAMMATICALL Y AND MAY NEED TO BE CHANGED TO SUIT FIELD CONDITIONS. (VERIFY WITH CITY.) SEE NOTE "B' ABIOVE. H. ALL MATERIAL SHALL BE DELIVERED TO TIHE SITE NEW, IN TIHEIR ORIGINAL UNBROKEN PACKAGES BEARING APPROVAL BY U.L, NEMA, NBFU, OR ANY OTHER APPROPRIATE AGENCY. I. PROVIDE TYPE WRITTEN DIRECTORY (LAt.tlNATED AND SEALED) INSIDE EACH PANEL DOOR. J. ALL WORK SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ( 1999 EDITION), AND ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES APPL YING TO THE PROPOSED CONSTRUCTION. IN THE EVENT OF A CONFLICT BETWEEN THE ABOVE AND THESE PLANS AND SPECIFICATIONS, . THE RESTRICTIVE SHALL GOVERN. K. CONTRACTOR SHALL MAINTAIN ONE SET OF "AS-BUILT" PLANS MARKED IN RED SHOWING EVERY CHANGE, ADDITION, DELETION OR MODIFICATION INCLUDING EXACT ROUTING OF CONDUITS. THIS "AS-BUILT" SET SHALL BE RETURNED TO TIHE CITY BEFORE FINAL ACCEPTANCE OF WORK. L CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM MEETING THE LETTER AND THE INTENT OF THESE PLANS AND SPECIFICATIONS. M. POLES STORED ON SITE SHALL BE HANDLED (INCLUDING DELIVERY AND SETTING) WITIH APPROVED STRAPS TO AVOID DAMAGE TO GALVANIZING. ACCEPT POLES FROM MANUFACTIJRER'S DELIVERY IN THE PRESENCE OF CITY VERIFYING ANY DAMAGE. POLES STORED SHALL NOT SET ON GRADE. SET POLES ON WOOD BASES AND TIJRNED 180 DEGRl!:ES EVERY 48 HOURS MINIMUM. TOUCH UP PAINTING (GALVANIZING) SHALL BE PER POLE MANUFACTURER'S REQUIREMENTS. N. SEE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 0. 'PROTECT ALL LANDSCAPING IN PLACE"-PROTECT IN KIND IF DAMAGED. CITY OF CARLSBAD 405 OAK AVENUE CARLSBAD, CA 92008 CHASE FIELD SPORTS LIGHTING ELECTRICAL UPGRADES PROJECT NO PKS-03-08 PROJECT ADDRESS: 3349 HARDING STREET CARLSBAD, CA92OO8 (AS f.;;U I LI ~f. T) ------------------~A.i_,Q{._,'C,G_ s-r~ee r ______ _ ______ 1 ' ' I ' l ___________________ ___,,, __________________________ ---1 Jcr~cRSO,U 5TRc€T LOCATION MAP NTS VICINITY MAP NTS 10/04/03 REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 E-MAIL : ee@reedcorp.net DATE INITIAL ENGINEER OF WORK INDEX SHEET NO ET-1 £-1 £-2 E-J . E-4 E-5 REVISION DESCRIPTION OF DATE ELECTRICAL SYMBOLS LIST SYMBOL DESCRIPTION o/ .. NEW llAl.l.flED UGHIING Pot.E ( ► • BACKUGIIT + JOFl) G) l!lllCAlES PlAN N()I£ NUMBER "1", SEE PlAN @ 0EN0JES DETAIL 'A", SIEET "E-1• A-1.3 \ HOM-10 PANEL "A", CIRCUIIB f1 ANO f3 ---CONOUrr/WIRE UNDER SLAB OR BELOW Gl!AIJE, 3/4" Ml~ CONOUrr /WIRE COIICEAI.EO AllO'IE CEJLIIG OR It W/11.LS -EX-EXllTINC CONOUrr /WIRE UNDER SLAB OR BELOW GP.olDE 0 JUNCTION 80X ~ 120V, OIJ1'LIX 20A RECEPTACLE AT +16" MNIMUM (OR /,S Nlll'Ell) 181 PULL 80X FLUSH IN GRAOC. BROOl<S #P81 OR 15 NOTED ON PlANS W.P. WfAlHER PROOF PR/MOE RJRNSH/INSTAl.l/CONNECT E.C. ELECTRICAL COM'RACTOR GFl GROUND FAULT IIITERl«JPT R£J:EPTACLE N.1.C. NOT IN CONTRACT c.o. CONDUIT ONL y (WAH srm PULL WIRE) EX EXIS11NG G GROIN) PQWER -UTILJD' GENERAL NOIES A. UTILITY POINTS OF SERVICE AND WORK / MATERIAL SHOWN ARE BASED ON PRELIMINARY INFORMATION ONLY BY TIHE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. B. LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE AND CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATING AND TRENCHING ON THIS SITE TO AVOID EXISTING DUCTS, PIPING OR CONDUITS, ETC .• AND TO PREVENT HAZARD TO PERSONNEL AND/OR DAMAGE TO EXISTING UNDERGROUND OF UTILITIES OR STRUCTURES WHETHER OR NOT SHOWN AND INSTALLED BY ANY OTHER CONTRACTS. THE ENGINEER IS NOT RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES WHETHER OR NOT SHOWN OR DETAILED AND INSTALLED BY ANY OTHER CONTRACTS. TIHE CONTRACTOR SHALL IMMEDIATELY NOnFY THE ENGPNEER SHOULD SUCH UNIDENTIFIED CONDITIONS BE DISCOVERED. THESE DRAWINGS AND SPECIFICATIONS DO NOT INCLUDE THE NECESSARY ELEMENTS FOR CONSTRUCTION SAFETY. C. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIAL l'IEOUIREMENTS ANO CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL WIRES, CABLES, PULLBOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL. PAY ALL UTILITY COMPANY FEES AND INCLUDE All REQUIREMENTS IN SCOPE OF WORK. D. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF METER PANEL TO UTILITY CO. FOR UTILITY CO. APPROVAL PRIOR TO ORDERING AND INSTALLATION OF METER PANEL E. CALL 'UNDERGROUND ALERT" BEFORE YOU DIG: SOUTHERN CALIFORNIA, 1-800-227-2600 F. UTILITY CONSULTANT, SAN DIEGO GAS ELECTRIC: MARIA HIGGINS LUPE VILLALOBOS 760/ 480-7647 760/ 480-7649 SDGE CONSTRUCTION ORDER NO. 2791980 SDGE PROJECT NO. 335399-020 -.... , DRAWiiuS ' \ -' ., [Ill) "/ i .. "'' \· :;, __,....,. ~f;,l>i,' ,.,,., ....... '•f;Y BUILT'' nESCRIP'I' lti ... · N ·• rd / J :¥, 1t-I a s:: -. r .... T/11.E SHEET " '' · , · ELECTRICAL ~ ~AN DEM((indft · ']53\ "1 I 20 law RCE EXP. DATE UECTRICAL SI Allt NE~ IIDR ,I 1 ELECTRI~/ if ; ,,.,, . , R[l~a~l7c ELECTRl!.l~rM.$'' -'1""""'··-~, ,-._ t/ft/p~ MUSCO 'OCTA/LS ' INSPECTOR DATE ~ CITY OF CARLSBAD I SH~TS I 1 ENGINEERING DEPARTMENT CHASE PARK LIGHTING RENOVATION TITLE SHEET A';_,.')<;,-,-3,-_... ~LL~ ~R P.E. :2-17-o.4 DEPUTY PUBUC WORKS DIRECTOR PE 51274 EXPIRES10/30/05DATE DWN BY: PROJECT NO.· DRA'MNG NO. INITIAL DATE INITIAL CHKD BY: OTHER APPROVAL CITY APPROVAL RVWD BY: PKS-03-08 DWG 412-7 • 042904 . g H <lJ N ·M if) Cl .... M 0 0 N M 0 0 N ' ,-t " 0 ,-t . " 0 .... ., ·rl r< i Cl I " "' r< "' (J) ., to ,... _______ _ I I I I I ' I ! EX. RETAINING WALL ! ____________ , __ 10/04/03 AEEDCORP EN01NEERING CONSULTING ELECTRICAL ENGINEERS i I ! I i I I I i ! I PLAN NOTES; 0 ® EX. 400A, 120/240V, 10, 3W MAIN SWITCHBOARD AND METER TO BE REMOVED PER SHEET E-2. EX. DISTRIBUllON PANEL 'DP' TO BE REMOVED. SEE DETAIL 'C', SHEET E-3. REMOVE EX. WOOD POLE WITH BALLFIELD 1000 WATT FLOOD LIGHTS. DISCONNECT CIRCUITS (FROM EX. PANEL 'DP') AND REMOVE ALL EX. WIRE. REMOVE POLE TO 24. BELOW GRADE. FILL IN POLE CAVllY, COMPACT AND PROVIDE CONCRETE COVER TO MATCH EXISTING. SAME AS NOTE 3, EXCEPT PROVIDE SOIL COVER AND GRASS SEEDING PER CITY REQUIREMENTS. EX. SCORERS TABLE TO REMAIN. DISCONNECT EX. SCOREBOARD POWER AND CONTROL WIRE. EX, 3/4" C. 2 #10 + G TO EX. PANEL 'DP' 30A/1P CIRCUIT BREAKER FOR SCOREBOARD AND 3/4" C. WITH SCOREBOARD CONTROL WIRE TO RESPECTIVE SCOREBOARD JACK AT RESPECTIVE SCORERS TABLE, EXACT ROUTING OF CONDUITS UNKNOWN. E.C. TO FIELD VERIFY EX. CIRCUIT BREAKER AT 'op'. DISCONNECT AND REMOVE WIRE. EX. 200A, 120/24DV, 11>, 3W CONCESSION BUILDING PANEL 'C' ON EXTERIOR OF BUILDING. TO BE INTERCEPTED RECONNECTED TO NEW 'MSA' PER NOTE 8. EX. 200A, FEEDER TO BE RECONNECTED TO NEW 'MSA' PER SHEET E-2 AND ONE LINE DIAGRAM. DISCONNECT AND REMOVE EX. 120V OUTLET AND SCOREBOARD JACK FROM LEG OF TABLE. PROVIDE NEW 120V OUTLET AND S.S. JACK PER SHEET E-2. REMOVE JUNCTION BOXES AND CONDUIT BELOW GRADE. DISCONNECT AND RELOCATE EX. CABINET WITH EX. MUSCO 'CONTROL-LINKS' CABINETS. SEE DETAIL 'C' SHEET E-3 AND SHEET E-2. DISCONNECT AND REMOVE EX. IN GRADE 120V OUTLET AND WIRE IN PULL BOX AT DIRECTION OF CllY. VERIFY LOCATION AND CIRCUIT. PROVIDE NEW OUTLET PER NOTE NO. 31 SHEET E-2. VERIFY EX. CIRCUIT LOCATION. EX. PLATFORM ANO FLAG POLE. TO REMAIN. EX. 1-4" SDGE SECONDARY TO BE REMOVED PER SHEET E-2. TO BE REMOVED PER SHEET E-2. EX. 1-4° SDGE PRIMARY TO SE REMOVED PER SHEET E-2. 4'<i?tr~t~~~~R P.~ 2-0-04 2061 Business Center Drive, Suite 110 Dvm BY: ___ PROJECT NO. DRAWING NO. Irvine, CA 92612 DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: --- DEPUTY PUBLIC WORKS DIR[CTOR PE 51274 EXPIRES10/30/05DATE (949) 752-1278 FAX: (949) 752-1287 1 EE~N~GIN~E:ER~Of~WO~R~KL __ ~R:E~V~I S:1:0::_N~D~E:_:S~C::_R:I P_T~l:O::_N:_ ___ Lo:'.'.TH~E~R'.!_Af'~PR'.'.:o'.:'.'.vA~LJ_~c:'.'.iTY.:..'.'.A:'.PP:::R'.'.'.ov:'.A~L~::R::VWD:=::B::Y::: ===-===P=KS~-=D=3=-=0=8====D=W=G=4=12=-=7:::'.J E-MAIL : ee@reedcorp.net L . " " H C- O) c- N N 0') 0 0 N ' rl ' 0 rl . N " X 0 0') -·---! l i I I I I I l • ! I I I l . ' \ \ \ \ \ PQI E B4 (144', 180') EX. SCOREBOARD 0 I I I 1' ) i , ; I I , , ; I FIELD NO. 3 ELECTRICAL SITE· PLAN NEW I ,,., " "' I n 0 PROJECT ADDRESS: 3349 HARDING STREET CARLSBAD, CA 92008 10/04/03 REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 E-MAIL : ee@reedcorp.net . - . . ' ' / ., .,.,.-;· ',';( . ·----~ . 1/ ,' ' ' '' ', •,.-.. ' ' .. • < • • ~ _,,.,,.,/ --.. I ' I I i I I ! ; i I ' j I l I l I I l I I I I I ! i """".,_ -'""" ~=----"""'--·➔" DATE INlllAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL OiHER APPROVAL PLAN NOTES· 0 @ G) 0 -@ @ G ® ® @) @ EX. 400A, 120/240V, 1 <&, 3W MAIN SWITCHBOARD AND METER TO BE REMOVED. EX. IRRIGATION CONTROLLER TO REMAIN. EX. POLE TO BE REMOVED PER SHEET E-1. TO BE DISCONNECTED PER SHEET E-1. EX. SCORERS TABLE. EX. RELOCATED 'CONTROL-LINKS' CABINET •. SAW CUT EX. CONCRETE. PATCH/REPAIR TO CITY STANDARDS. NEW CHRISTY N9 IN GRADE PULL BOX. PROVIDE NEW 120V, 20A, GFI, W.P. OUTLET. MOUNT TO EX. FENCE POST AT + 42". INTERMATIC NO. WP101 OC LID. CITY TO RELOCATE EX. BLEACHER TO THIS LOCATION. TRENCH ALONG EX. FENCE LINE. PATCH/REPAIR EX. TURF AND INFIELD. @ IWO 1 • C.O, (FUTURE SCOREBOARD CONTROL ANO FUTURE 120V POWER) @ @ @ @ ® ® ® @ @ @ @ @ @ @ CHRISTY N16 IN GRADE PULL BOX. PROVIDE CONSTRUCTION SIGN PER DETAIL 'E', SHEET E-4. CHRISTY N30 PULL BOX. CHRISTY N40 PULL BOX. 120V, GFI OUTLET. 2• C. 3 {/4 + 1 {14G + 1" C.O. SPARE. 3/4" C. 3 #10 + 1 {110G + 1 • C.O. 1 1 /2" C. 3 {16 + 1 {IBG AND 2 {/10 (BACK LIGHT) INTO POLE + 1" C.O. 1 1 /2" 3 #5 + 1 {/6G INTO POLE + 1 • C.O. 2" C. 6 #4 + 1 #4G + 2 #10 (BACK LIGHT) + 1• C.O. 3/4" C. 2 {/10 + 1 #10G (OUTLET) 1 /2" C. 6 /18 + #BG. 1 /2" C. 6 #B + 1 #BG + 1" C.O. INTO POLE. TO PANEL 'A': 3-1" C.0. 2" C. 6 #4 + 1 i/4G. 1 1/2" C. 6 #8 + 1 i/BG. 1 1/2" C. 6 i/8 + 1 #BG. 3/4" C. 2 #10 + 1 i/10G. (BACK LIGHT) '27' TO PANEL 'P':. '¢.:.J 1" C. 4 /110 + 1 i/1 OG (THREE OUTLETS) TO PANEL 'P': 1" C. 5 #8 + 1 i/BG (FOUR OUTLETS) 3-1" c.o. 3-1" C.O. {FUTURE SCOREBOARD CONTROL) MOUNT 4" X 4 • X 2" JUNCTION BOX INSIDE BUILDING AS DIRECTED (FUTURE PUBLIC ADDRESS) PATCH/REPAIR BUILDING. PROVIDE PULL BOX, FLUSH IN GRADE. PROVIDE W.P ., Gfl DUPLEX OUTLET IN PULL BOX WITH FLEX CONDUIT. SEE DETAIL 'A' SHEET E-4. PROVIDE W.P. J-BOX AT + 42" WITH 0-50 MINUTE TIMER (INTERMATIC NO. FF60M) TO CONTROL OUTLET AT PITCHERS MOUND, CIRCUIT P, 9. PROVIDE COVER PLATE INTERMATIC NO. WP1010C. AFTER SDGE SYSTEM INSTALLED COORDINATE WITH SDGE TO DISCONNECT EXISTING 1 ¢ SERVICE. REMOVE EXISTING TRANSFORMER PAD AND REPAIR SIDEWALK. REMOVE EXISTING SDGE WIRE AND RISER ON POLE. NEW 1 -4 • C.O (DB) FOR NEW TRANSFORMER TO RISE UP EXISTING POLE. SAW CUT SIDEWALK AND PATCH/REPAIR SIDEWALK TURF. @ NEW 2-4" C.O. {DB) @ NEW TRANSFORMER PAD {SDGE NO. 3425) 78" WI~·;. 'cib\ SET BACK OF SIDEWALK PER SDGE REQUIREMEN • , ,. · QY 'l..''c,t>, (FUTU~ l,.._illt',6TLOI>< Cct<TR<>Uf;itl.J , @ CH li,1$TT Ne, f'i/i.1. ~~ ,, (tVTUf'.€ lf<.f<.lt'..•T"tcll<-a,.,-~ .,_1.,t.-'l.) ,,,qyest ~;f:.UIL ~" )o,c.1 E. H,t;, "' -,,., /! a ., 5 ~ No.1531 ·, <'. (/ a-ic r: "" E,p: t/30/C ~~• "' I ~ RCE ::iD l EXP. cl I ~"' I !7 I,; DATE ,,~'t. ii (¥: tf1: Rt11Eal? 1 ... .. 1/i,/4~ INSPECTOR ,-- DATE ~ CITY OF CARLSBAD I SHE:TS I ENGINEERING DEPARTMENT 2 CHASE PARK LIGHTING RENOVATION ELECTRICAL SITE PLAN NEW WORK APPRO~ !'JIL~~P.E. $1~· · .,.,'\....,_ 2-0-o4 DEPUTY PUBLIC WORKS DIRECTOR PE 51274 EXPIRES10/3Q/05DATE DWN BY: PROJECT NO. DRAWING NO. DATE INlllAL CHKD BY: CITY APPROVAL RVWD BY: PKS-03-08 OWG 412-7 ' ., -f 042904 m N 0 -0) C =E C') .,::.. ...... I\) I ~ NOTE EC TO RETAIN MUSCO LIGHTING : . . TO FIELD HOOK-UP 'CONTROL-LINKS' to NEW LIGHTING O" H X 72" W 9 X 24" DEEP I'--.. SYSTEM ~ I I, II EX OUTDOOR STEEL CABINET !NEMA 3R) • WID::I lt::IIEBt::lllL ttl!.!SQQ 'QQt::IIBQL Llt::l~s• 1 IGt:IIlt:K, QQt:dIBQI SYSTEM !;;lll;llt;E1S REMOVE AND RELOCATE ENTIRE OUTDOOR CABINET. REMOVE EXISTING BELOW GRADE WIRE AND CAP OFF CONDUITS 6" BELOW GRADE. PATCH AND REPAIR CONCRETE. ./ EXISTING CONTACTOR CABINET S.C.E. MS' V, 1!11, 3W ER / ~ OITTOOOS • 400A, 120/240 (EX. SDGE MET NO. 1667997) 90" HIGH X 48 "WIDE • 24" DEEP SERIES RATED CIRCUIT BREAKERS: A. WITH SIEMENS CIRCUIT BREAKERS 1 . 600A 3P MCB IS TYPE LXD6 RATED 65KAIC. 2. 400A 3P BRANCH IS TYPE JXD2 RATED 65KAIC. 3. PANELS L & P ARE TYPE BL-H, SERIES RATED. 65KAIC TO SIEMENS JXD2. CONCRETE PAD APPROX. 18 FT. LONG X 8 FT. DEEP WITH CHAIN LINK FENCE ENCLOSURE SEE "SERIES RATING NOTE" THIS SHEET AVAILABLE FAULT CURRENT: 42,000 A.I.C. NEW 'MSA', OUTDOOR, 120/20BV, 3!11, 4W, 600A SWITCHBOARD AND METER SEE 'MSA' NOTES THIS SHEET W EX. CONTROL V LINK CABINETS RELOCATED NEXT TO NEW 'MSA' AREA 1/4" C. 4 #6 + 1 /16 G. DO ~~ I EX. PANEL 'DP' DISCONNECT 0 4. 200A 2P BRANCH IS TYPE FXD6 RATED 65KAIC. PAD L H co OCK ASP VER ~ ~ I I () () ! () I I I " I I I I I V I AND REMOVE. REPAIR CONCRETE. REMOVE EXISTING BELOW GRADE WIRE AND CAP OFF CONDUITS 6" BELOW GRADE. PATCH AND REPAIR CONCRETE. I:),, UGPS ~ "v ~ ~ SLAB ~ 400A SWITCH/F USE (MAIN) TWO 100A SPA RES 200A SWITCH/F USE FOR EX. PANEL ·c· B. WITH G.E. CIRCUIT BREAKERS 1. 600A 3P MCB IS TYPE SGH RATED 65KAIC. 2. 400A 3P BRANCH IS TYPE SGD RATED 65KA. 3. PANELS L & P ARE THQB, SERIES RATED 65KAIC TO SG D CB. 4. 200A 2P BRANCH IS TYPE SFH RATED 65KAIC. UGPS 200A 2/P 600A 3/P 400A 3/P PROVIDE MIN. 2-100A/3P SPACES PANEL L p r-----, I I I : ~ -j l=l--le----1--+-BALLFI ELD LIGHTING CIRCUITS TO PANEL 'C' CIRCUIT P,2 2 #12 FOR MUSCO CONTROL CIRCUIT [EX. • ll. ,., . I :.~' . .. ·~-. ""· '. ,, r.. ' ~, : % , -~~,.,: " ; ; . ,' ',("'\ , '.· .. ~· ·. . ~ ,,•.·~ ; :':''":·"';: . ~ ·~ -. -~"-· ·,-:• ·: :-."'.· '. : : t ,; "f,,. 'i,: i,. •." -' 1 ; --.... :. ~ ·.-' --~ ' :as· J'. .:, . ' ' : •. ;; " "i ' > !·, ·~-.,,;, .' ' '<>' ' . :" .•: ·. : s , ... _ ·.' ' ··,)•-·' J./k ... ,.A1, • fo ' :(:•-":.. : : . .; "' 2-4 N c.o. -- TO SDGE TRANSFORMER 120V CIRCUITS I ~ MUSCO CABINET ~ REMOVE CONDUIT TWO-MUSCO_ CONTACTOR MUSCO R.E.C. CABINET -MUSCO CONTROL CABINETS - - -THREE O O A SWITCHES 11-30A/3P 1-60A/3P AND WIRE TO CONTACTORS EXISTING "CONTROL LINKS' CABINET AND EX. PANEL MAIN SWITCHBOARD NOTES: A. SERIES RATED SYSTEM: 1. THE ENTIRE MAIN SWITCHBOARD AND ELECTRICAL PANEL SYSTEM SHALL BE UL LISTED FOR A 'SERIES RATED' SERIES RATING OF 50,000A RMS SYMM WHEN USED WITH DOWN STREAM SERIES RATED CIRCUIT BREAKERS AND, OR DEVICES. 2. THE SHORT CIRCUIT CURRENT RATING OF EACH PANEL SHALL BE EQUAL TO THE LOWEST INTERRUPTING RATING OF ANY DEVICE INSTALLED BUT NOT MORE THAN THE MAIN RATING AT THE SYSTEM VOLTAGE. ADDITIONAL OR REPLACEMENT DEVICES SHALL BE OF SAME MANUFACTURER, TYPE DESIGNATION AND AN EQUAL OR GREATER INTERRUPTING CAPACITY. 3. PROVIDE RED ENGRAVED PLATE WITH WHITE LETTERS: "SWITCHBOARD IS SERIES RATED. REPLACEMENT DEVICES SHALL BE OF SAME MANUFACTURER, TYPE DESIGNATION AND AN EQUAL OR GREATER INTERRUPTING CAPACITY." B. COPPER BUSSING SHALL BE 1000A/SQ. INCH FOR 100% RATING. ALUMINUM BUSSING SHALL BE 750A/SQ. INCH FOR 100% RATING. C. ALL SECTIONS OF SWITCHBOARD (HORIZONTAL AND VERTICAL) TO BE FULLY BUSSED FOR FUTURE ADDITIONS. D. IF SWITCHBOARD IS LOCATED AGAINST A WALL THE TOP OF THE SERVICE/SWITCHBOARD LINE-UP SHALL BE BOLTED TO THE WALL WITH- IN lHREE FEET OF EACH END WITH 1/4" THICK ANGLE IRON OR P100 UNI-SlRUT AND FITTINGS OR WITH EQUAL TOP SUPPORT. IF SWITCHBOARD IS FREE STANDING OUTDOOR UNIT THAN BOLT TO CONCRETE SLAB WITH 1 /2" o PHILLIPS RED HEAD WEDGE ANCHORS 4" EMBEDMENT. CAT. NO. WS-1252 (4) BOLTS PER UNIT (2 AT EACH END). E. CONTRACTOR SHALL SEND SWITCHBOAAD SHOP DRAWING TO POWER CO. REPRESENTATIVE FOR APPROVAL BY POWER CO. AND CONFIRMATION THAT SWITCH GEAR COMPLIES WITH POWER CO. REGULATIONS. F. ALL DIMENSIONS OF SWITCH GEAR ARE BASED ON RSE-SIERRA (714/529-3471). CONTRACTOR IS RESPONSIBLE FOR ANY SUBSTITUTION OF EQUIPMENT WITH GREATER DIMENSIONS THAN MANUFACTURED BY RSE-SIERRA AND FOR ALLOWED SPACE AND CODE CLEARANCES. G. THE LANDING LUGS IN lHE UNDERGROUND PULL SECTION, SIZED PER MAIN SWITCH, ON SERVICE SECTION CONNECTED LOAD. DISCONNECT LINKS FROM LANDING LUGS THE UNDERGROUND PULL SECTION TO EACH SERVICE SECTION BUS PER UTILITY COMPANY SERVICE GUIDE (U.C.S.G.). H. CONTACTORS AND/OR RELAYS TO MOUNT IN SEPARATE SECTIONS WITH HINGED (LOCKABLE) DOORS. TIME CLOCKS AND/OR ANY TOGGLE OR PUSH BUTTON ON-OFF DEVICES TO BE MOUNTED IN SEPARATE BARRIERED SECTION WITH HINGED LOCKABLE DOOR AND TO HAVE NO LIVE CONTACTS OR BUSSING EXPOSED TO OPERATOR. (COMPLY WITH CAL-OSHA TITLE B, ELECTRICAL CODE 2320. 1 AND 2320.2. I. OUTDOOR SWITCH GEAR TO HAVE HINGED PAD LOCKABLE DOORS AND PAD LOCK COVER WITH DOOR HANDLE HARDWARE AT METER SECTION CAPABLE OF TWO PAD LOCKS. PANEL: P PANEL VOLTAGE: 208/120 3♦ 4W CIRCUIT CODE: blank or N : NON-CONTINUOUS f3US: 100A L : LONG-CONTINOOUS OAlE: 08/27 /OJ TIME: 11:51:33 MAINS: MLO MOUNTING: IN 'MS'.' R : DBWIOABLE RECEPTACLES JOB: 1929 ~ RATING: 10,000 k , klTCHEN NO. OF EQUIPMENT: 0 : ~ t ~ LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION t ~ ~: DESCRIF'JION (NOlt:) M R L ., ijiB I 4'C A8C ♦A ♦8 I ♦C L R M (NOTE) OESCRIP'TIOH 1 20 1 OUTLET FIELD 1 1 l!O 11!() MUSCO CONlROL 20 1 2 3 20 1 OOTLET FIELD 2 180 I I SPARE 20 1 4 5 20 1 OUnET FlE'.LD .3 ~ I SPARE 20 1 • 7 20 1 OUTL£T PICNIC 11!() i----i 8 • 20 1 OUTLET -PITCHEfll A I I I I 10 11 I I 12 PANEL NOTtS, PHASE TOTALS oA: 360 l♦B: 180 I ♦ o 180 TOTAL CONHECTID VA ;so CONNECTED VA (CODE N) 360 @CIRCUIT ~ .w. o-eo MINUTE TIMER. SEE NOTE NO. 2, S • E-2 CONNECTID VA (CODE L) 0 CONNEC'TED VA (CODE R) 0 COHNECTID VA (CODE K) 0 PANEL CONNECTED KVA 0.4 PANEL DEMAND k'IA 0.4 PANEL DEMAND AMPS 1.0 HIGH ♦ AMPS W/LCL 3.0 "•·· .. . ··~-' ' - UFER GROUND IN SLAB PROVIDE 2" C. 3 ff 3/0 ----- + 1 #6 G r------, r EX. 'MS' TO TWO i IF BE REMOVED , I _,.,---EX. 200A/2P SW/FUSE ~ TO BE REMOVED l;l .l~ .,,--EX. DRIVEN GROUND L----J.,-TO BE REMOVED 3" CLOSE NIPPLES 1-BALLF"IELID LIGHTING CIRCUITS 'DP' N.T.s.© EXISTING SWITCHBOARD 'MS' I -~- r--~------:::-:::J-~1---NEW PULL BOX AT EX. 'MSA" DISCONNECT AND REMOVE ENTIRE SWITCHBOARD AND CONCRETE PAD RE-SEED AREA N.T.S. HEAVY DUTY STAINLESS STEEL HINGE 3 PART LATCH VAULT 110° MIN TYPE DOOR HANDLE __ __,, 10 GAUGE GALVANIZED STEEL SECURITY COVER 3/8" DIAMETER SI-IACKLE PADLOCK ........ DOOR HANDLE SECURITY COVER DOOR HANDLE ARE:A LIGHT FIXTURE: LITHONIA NO. KAD-250S-R3-208V-LEX-DB2-CR (250W HPS, ADJUSTABLE KNUCKLE, SLIP FIT BRACKET, POLYCARBONATE L£NS, BRONZE CORROSION RESISTANT FINISH. VERIFY TENON SLIP FIT WITH MOUNTING ARM PROVIDED WITH POL£) WIREWAY COVER PLATE EPA -1.2 SQ. FT. L£NGTH -17 1/2" WIDTH -17 1/2" DEPTH -7" ),:• I WT -42 LBS l~ //. LEXAN LENS / i 2 J/8" HUB 2 J/8" DIA. GALV. REDUCER BY CONTRACTOR (COORDINATE W /FIXTIJRE MFG FOR EXACT SIZE) l-0----+----MOUNTING BRACKET BY MUSCO ±6" 1 ... ;---11" __ .. GROUNDING KIT BY MUSCO MOUNTING BACK PLATE BY MUSCO LIGHT POLE ..___ __________ HANDHOLE BACK SPECIAL NOTfS PROVIDE BULL HORN MOUNTING BRACKET FOR TWO FIXTURES ON POLES NOTED LIGHT A. ALL PANEL SCHEDULES TO MATCH EXACT FIELD PANEL: L PNilEL VOLTAGE: 208/120 34> 4W CIRCUIT CODE: blonk or H : NON-coNTINUOUS INSTALLATION (AS-BUILl) CONDITIONS. PROVIDE "CORRECT"' PANEL SCHEDULE INSIDE PANEL WITH CORRECT CIRCUITS, ELECTRICAL LOADS AND FEEDER SIZE AND WIRE TYPE TO PANEL (le: NO. 3/0 COPPER. THHN). BUS: 400A OA'ft:: Oll/04/03 TIME: 13:00:07 lilA!NS: MLO MOUNTING: IN 'MS.A' JOB: 1929 AIC RATING: 10,000 =~ t~ LOAD DESIGNATION CONNECTED.VA D£'SCRfPTlON (NOTE) M R L •• OB I ♦C ABC ♦A ♦B I ♦C L R M 1 L 30 , POLE A1 FIELD 1 14 A 3 2475 4125 • 3 L -3 2475 l 4125 I 5 • L " ; -2 ~ 13300 • 7 L 30 POLE A2 FIELD 1 14 A 2 16!50 I JJiiol • • L -3 12475 l 41251 5 11 L I/ ' -3 ~ 14125 ' 13 L 30 POLE A2 FIELD 2 ,. A 3 24751 -mo, 5 15 L -2 I 1850 l 3300 I • 17 L ,, ; -3 I 2475 14125 5 1• L 30 , POLE '3 ~ELO 2 ,. ' 24-7!51 412!5 I • 21 L -3 12475 I I 4125 I 5 2' L ' 2 ~ I 3300 • 25 L 30 POLE '3 ~ELO 3 14 2 1eeo I J 3300 I • 27 L -' 12475 I 41251 5 29 L ' -3 12475 I 4125 5 31 L 30 POLE •• FlElD 3 • A 3 2-4-751 4125 I 5 33 L ' 11650 I 13300 I 4 35 LI/ ' -3 I 24115 14125 5 L , LONG-COH'rlNIJOUS R : DEMANDABL£ RECEPTACLES · K : KITCHEN NO. Of' EQUIP~ENT: O UWl OESIGMATK>N ~~ ~: (NOTE) DESCRIPTION A. POLE 81 FIELD 1 r7 50 L 2 L 4 -, 3 L 5 A POLE 82 F1E1D 1 17 ,o , L • -L 10 -, ' L 12 POLE 82 FIELD 2 l/ 50 , L 14 -L 16 -3 L 18 A POLE 83 FILED 2 V 50 , L 20 -L 22 -3 L 24 POLE 83 FlELD 3 " 50 I , L 26 -L 28 -" ' L 30 8 POLE 84 FIELD ,3 l / 50 L 32 L 34 -3 L ,. , B. ALL PLUG-IN OU1LET DEVICES WITH GROUND OlJTLET SHALL HAVE GROUND CONNECTION AT TOP OF DEVICE + 15" TO CENTER TO TOP OUTLET. C. CONTRACTOR SHALL NOT INSTALL MORE WIRES IN A CONDUIT THAN SHOWN ON PLANS. NUMBER OF WIRES IN A CONDUIT ARE BASED ON DERATING VALUES IN NATIONAL ELECTRICAL CODE. IF CONTRACTOR ELIMINATES VARIOUS CONDUITS SHOWN ON PLANS AND INSTALLS ADDlllONAL WIRES IN A CONDUIT, WITHOUT PRIOR APPROVAL, THE WIRING WILL BE CORRECTED AT CONTRACTOR COST. D. ALL OVERCURREITT PROTECTION DEVICES (CIRCUIT BREAKERS, SWITCHES) SHALL BE U.L, LISTED FOR 75' C. TERMINATIONS. ALL WIRE RATING AMPACITIES BASED ON 75' C. (THHN/rHWN) COPPER. NO ALUMINUM WIRE ALLOWED. E. ALL BRANCH CIRCUIT JUNCTION BOXES TO COMPLY WITH THE 1999 NEC 370-16 FOR SIZE RELATED TO NUMBER OF WIRES INSIDE THE JUNCTION BOX. r-t-1 LOCATION. PICK UP AND EXTEND EX. 200A/2P I ~~ }1 EX. FEEDER ELECTR1CAL LOAD PANEL 'L'= 390A EX. 'C' = 150~ MAIN I ...... 540A EX. PANEL 'C" ---I. ___ : J;, EX. 2" C. 3 #3/0 + 1 #6 G ~"""-EX. GROUND 8 FT. ONE LINE ..l'--------16'-6" APPROX._.,.._ ____ ,_, )I<--¥-12" ALL AROUND 30" ., '1 X-)t~ x-x--o-<-x-x-i--0-x-x 'MSA' CONTROL CABINET 1 oa· ----+---¥--,!'--- (VERIFY LENGTH) 36" 6" 72" ---,j, X -X -~--k -X ---0--X 24" 42" WIDE GATE PROVIDE NEW ~ CONCRET PAD ~ SERIES RATING NOTE: SERIES CONNECTED SYSTEM HAS BEEN SPECIFIED FOR THE TYPE OF FUSE-CIRCUIT BREAKER AND CIRCUIT BREAKER-CIRCUIT BREAKER COMBINATION. THE ELECTRICAL CONTRACTOR SHALL SUBMIT TO ELECTRICAL ENGINEER A COPY OF DOCUMENTATION FROM SWITCH GEAR MANUFACTURER. THAT CONTRACTOR PROPOSES TO USE, AND DEMONSTRATE/DOCUMENT, THE COMPLIANCE OF THEIR SUBMITTED COMBINATION . THE EQUIPMENT ENCLOSURE SHALL BE LEGIBLY MARKED ON THE FIELD TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A SERIES COMBINATION RATING. THE MARKING SHALL BE READILY VISIBLE AND STATE "CAUTION-SERIES RATED SYSTEM" PER N.E.C. ARTICLE 110-22. 42,000A. AVAILABLE IDENTIFIED _ _--. •-· CONCRETE PAD 6' REPLACEMENT COMPONENT REQUIRED. IF PROPOSi!U ... ""'')\ PLANS, CONTRACTOR SHALL RESUBMIT SUBSTIT D · •) OCP DEVICE TYPE IS DIFFERENT THAN SPECIFtE ON • • ... OCP DEVICE CATALOG NUMBER TO BUILDING P. A• RTMENT , i'_ · 11 ~~ BUILT" 4~ ,. ?,iri,ra, RCE 7,r:;, EXP. $/,u/of; DATE ' 37 L 20 BACK LIGHT C • 600 I 540 I PANO. 'P' 60 L 30 39 LV ' • I 600 I I 180 I -L 40 ~ ','"~" m oo,="=' -~,~-<_,z .ef) ,/';t!!t:r1.:.-•~:;· .. 1 ~:...,._...- F. COITTRACTOR SHALL SEND SWITCHBOARD SHOP DRAWING TO POWER CO . 41 L 20 1 CONlROI. I 180 I 180 -I/ PANEL NOTES: PHASE TOTALS ♦A: 37440 l♦B: J70BO l ♦C: 36660 TOTAL CONNECTED VA 111160 @CIRCUIT COIITROUEl 8Y El<ISTIMG 30A/3P COIITACTOR. CONNECTID VA (CODE N) 0 @CIRCUR' COfffROU.ED 8Y EXISTING 60A/3P CONTACTOR. CONt/ECrnJ VA (CODE L) 111160 @CIRCUrr CONlROllED frt NEW Tlt.lE CLOCK 00. 1 CONN£Cll'O VA (CODE R) 0 CONNECrnJ VA (CODE K) 0 PANEL CONNECTED KV'A 111.2 .. PANEL DElW«J f()!A 139.0 PANEL DEMAND AMPS .385.8 HIGH ♦ AMPS W/LCL 390.0 3 L 42 REPRESENTATIVE FOR APPROVAL BY POWER CO. AND CONFIRMATION THAT SWITCH GE:AR COMPLIES WITH POWER CO. REGULATIONS. t---t----t-------------1-----l--.l------l-_J fsHEfl CITY OF CARLSBAD I SHE6ETS I ~ ENGINEERING DEPARTMENT ;=:::::=:'...'==================='-===== 12/04/03 REEDCORPENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 t-MAIL : ee@reedcorp.net DA TE INlllAL ENGINEER OF WORK • DA TE INlllAL REVISION DESCRIPTION OTHER APPROVAL DA TE INlllAL CITY APPROVAL CHASE PARK LIGHTING RENOVATION ELECTRICAL DETAILS A~-~LLl~~~P.E. ?-~,,,,. DEPUTY PUBLIC WORKS DIRECTOR PE 51274 EXPIRES10/30/05DATE DWN BY: __ _ CHKD BY: __ _ RVWD BY: PROJECT NO. PKS-03-0B I DRAWING NO. . DWG 412-7 042904 AS NEEDE 4" SAW CUT PATCH/REPAIR EXISTING CONCRETE PER CllY SPECIFICATIONS WHERE REQUIRED 24" FROM FIN. GRADE (SLAB) TO TOP OF TOP CONDUIT +--------=; SEE ADDITIONAL TRENCH DETAIL BELOW 18" MAXIMUM PROVIDE CHAIN LINK FABRIC TOP WITH SUPPORTS TENSION ROD EX. CONCRETE WALKWAY (VERIFY DEPTH) NEW TRENCH CONDUIT(S). PROVIDE CONDUIT SADDLES FOR SEPARATION. SEE PLANS FOR QUANTITY AND SIZES OF CONDUITS NATIVE BACKFILL TO A MIN. I S" 90% RELATIVE MIN. MIN. COMPACTION O.D. J rrJ"' 10" 10" END POST __..-TOP RAIL / 8' CHAIN LINK FABRIC SELF LATCHING LATCH WITH PAD LOCK HASP 10' SEE DETAIL AT RIGHT TOP RAIL------Et-----t FENCE POST ------1 CHAINLINK FABRIC---;; FABRIC ON INSIDE OF POST MID RAIL------·- BOTTOM RAIL COLD JOINT ·-... FINISHED GRADE TURF MOW CURB CONC. FOOTING __ _ SEE FENCE SCHEDULE CONCRETE BLOCK-------:t;,; 2" X 4" X 6" COMPACTED SUBGRADE F ~ C. w w 9 "' b rr, -G FENCE AND GATE UNISTRUT CHANNEL FILE DOWN ROUGH EDGES ·oe· BOX LEMURE 8" X 8" X 6" CABINET PROVIDE 20A, 120V, DUPLEX Gfl OUTLET IN CABINET. 1" RIGID GALV. STEEL CONDUIT -+----41 SET TIGHT TO POLE. 36" r 12· : " ,-,•·.·""., ' • ~ :, ,~" '• : < 1/4" STEEL U-BOLT ROD. VERIFY SIZE FINISH GRADE .5,.j I 'f.5 2.5" 2,5" 2· 2' 2" 2· 2• 2· ' 2· .5 .J 1,5 1 l FENCE FOOTING P!NCE 6' 8' 10' HEIGHT A 6" 8" 12' B 2" 2" 2" C 3' 4' 5' ,--NEW 'DPA' W ~ 0 5 112' 51/2" B" E 1112" 11/2" 11/2" 18 /14 X ,0-18" 0.C, F 12· 12" 12· ELECTRICAL G 4" CABINET FENCE FABRIC: 9 8" CONCRETE SLAB 3000 PSI O 28 DAYS WITH #4 @ 12" O.C. E.W. EXCAVATE SOIL BELOW THE SLAB GA CHAINLINK FENCE POST EB B 12" ALL AROUND 12 CONCRETE FOR 'DPA' TO A MINIMUM DEPTH OF 18 INCHES TO A FIRM GROUND AND FILL BACK IN 6-INCH LAYERS. COMPACT BACKFILL TO 90% OF THE MAXIMUM DRY DENSITY DETERMINED BY ASTM D 1557 1/2" ,ii PHILLIPS RED HEAD WEDGE ANCHORS 4-1/8" EMBEDMENT. (4) BOLTS PER UNIT, 2 EACH END. ICBO NO. 1372. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. PAD \ PAINT FRONT <I: BACK OF SIGN 1'11111 ONE: COAT Millf PRIMER <I: ,----TWO GOA 7:5 GLOSS WHITf fNAMfL, BORDfR <I: L£TTfRING 'l,111/ GLOSS BLACK E:NAME:L I r 1 /2" DIA. x 5" LAG SOLT W/111 WASHER, 6 REQU/RfD, DRILL PILOT HOLES IN POSTS /J/4" STRUCnJRAL 1 DOUGLAS FIR A-C PLYWOOD, TOUCH SANDED EXTERIOR GLUE 11lp ~VING CARLSBAD !I ~ 1 1 [,.,"-ALLOW 10· SQUARE AREA FOR ~ r VI I/ CITY OF CARLSBAD LOGO TO I/ Bf PROVIDED TO CONTRACTOR C~AS[ ~l[LD SPORTS UGHTING I I I FOR INSTAtLING ONTO SIGN P~OJfCfi NUMB[R PKS 03-08 : : Fpr rlntormation Call 760/ 43~-3949 I Please Do Not Ente~ I ' I 2' I •• J' ~ r\ V' I\ I/ V' V' CONTRACTOR TO FUR NISH >- 2 J 4 5 8 7 8 ALL SPLICES INSIDE JUNCTION BOXES TO BE TAPED OFF WITH SEALANT NEW PULL BOX W CHRISlY NO. N9 V MOUNT AS DIRECTED BY CITY FINISH GRADE ml,--24". SEAL TIGHT, FLEX CONDUIT WITH NO. 12 WIRE (120V) BOLT 2 W.P. JUN BOX TO SIDE or PULL BOX COMPACT GRAVEL BASE . 12" BELOW PULL BOX AND 4" UP INTO PULL BOX 12(N, W.P., GFl, DUPLEX OUTLET t.tOUNTED TO SINGLE GANG SEALED J-BOX. PROVIDE INTERIMTIC NO. WP1010C I.ID. 3/4" C. 2 #10 + 1 l10G (PVC, SCH-40) TO PANEL 'p', 9 IN GRADE OUTLET PIJt I BOX SCHEPULE (1) • CHRISlY NO. N9 (10" X 15" X 12" DEEP) WITH FL9T LID. (1X) • SAIAE AS (1) EXCEPT WITH 12" DEEP EXTENSION. (2) • CHRISlY NO. N16 (12" X 22" X 12" DEEP) WITH Fl.15 LID. (2X) • SAME AS (2) EXCEPT WITH 12' DEEP EXTENSION. (J) • CHRISlY NO. N30 (1J" X 24" X 12" DEEP) WITH Fl.JO LID. (JX) • SAME J>S (3) EXCEPT WrTH 12" DEEP EXTENSION. (4) • CHRISTY NO. N38 (17" X 30" X 12" DEEP) WITH FU16 LID, (4X) • SAIAE AS (4) EXCEPT WITH 12" DEEP EXTENSION. 9 (5) • CHRISTY NO. N40 (24" X 30" X 14" DEEP) WITH N40T LID. 10 (5X) • SAIA[ AS (5) EXCEPT WITH 10" DEEP EXTENSION. 11 (6) • CHRISlY NO. N44 (2D" X 44" X 12" DEEP) WITH N44 UD. (8X) • SAIAE AS (6) EXCEPT WITH 8" DEEP EXTENSION. (7) • CHRISlY NO. N48 (30" X 48" X 14" DEEP) WITH H48T2 LIO. 14 (7X) • SAME AS (7) EXCEPT WITH 1 o• DEEP EXTENSION. 15 (e) • CHRISlY NO. N52 (30" X ao· X 14" DEEP) WITH N52-625 WITH STEEL LID. 16 (eX) • SAIAE AS (e) EXCEPT WITH 1 o· DEEP EXTENSION. 17 (TL) • TRAFflC LID (STEEL) WHEl!E SHOWN. ALL LIDS TO BE BOLT DOWN. LIDS TO BE "FIBERLYTE" FOR PULL BOXES NO. 1, 2, 3 ANO 4. CONCFtETE LIDS FOR PULL BOXES NO. 5, 6, 7. STEEL Lil FOR PULL BOX NO. 8. AU. LIDS TO BE ENGRAVED "ELECTRICAL" FOR POWER (OR "slGNAL'FOR OTHERS). AU. BOXES TO SET ON 12" COMPACTED GRAVEL BASE WIDTH X LENGTH OF BOX. 'SPLICES: COPPER CONDUCTOR SPLICES AND TAPS Of #eAWG AND SIAALLER SHALL BE MADE WITH WATERPROOF WIRE NUT CONNECTORS. KING SAFETY PRODUCTS #621, #622 OR f6~. WHICH ARE THREE SIZES (OR EQUAL) THESE WIRE NUTS ARE U.L LISTED FOR "WET" LOCATIONS AND CONTAIN A SEALANT PASTE. COPPER CONDUCTOR SPLICES OF feAWG AND LARGER SHALL BE MADE WITH SPLIT-BOLT CONNECTORS SUCH "5 BURNDY "sERVIT' (OR EQUAL) WITH DOUBLE WRAPPED "sCOTCH" #"-'+ ALL WEATHER VINYL PLASTIC ELECTRICAL TAPE OR WITH •E-Z SEAL" #2200 VINYL INSULATING PADS. BY 3M, OR WITH SIERRA/IOIAIC #4000 VINYL SEAL PADS. X 0 0 0 ~--BOLT DOWN CONCRETE LID WITH ENGRAVED WORD "SIGNAL" OR "ELECTRICAL" ---TOP OF BOX TO BE FLUSH WITH FIN. GRADE WRAPPED RIGID CONDUIT TO PULLBOX I I AND INSTALL SIGN W.P. SPLICE CONNECTOR FINISH GRADE FILTER FABRIC O.D. 4"MIN. WELL 'i/ii-!~;;.;:;1~!"--~ TAMPED SAND/GRAVEL BEDDING W/0.5" SIZE MAX. CONDUIT TRENCH (NOTE: TRENCH NOT WITHIN CONCRETE TO BE SIMILAR AND FLUSH WITH EXISTING GRADE) Sf:RVICE DISCONNECT IF' N!UTIW. SUS IS INSULATED FROM THE ENCLOSURE. INSTALL A BOND1f'fG JUMPER OR SCREW (N,E.C. 250-28) SEE N.E.C. Rm lYPE AND SIZE OF tAA.TERIAI... AND PROTECTION OF THE GROUNDING ELECTRODE CONDUCTOR (N.E.C. 250-52(0) FOR WiTERtAL., N.E.C. ~0-84 FOR INSTAU.AllON AND 250-66 F'OR SIZE). r 1> r APPROVED SYSTEM GROUND CLAMPS SHMJ. ,I I BE ==••u: N!.W CONCRETE SLAB 2" MIN. 00:NI NPIES· SIPE YIEW POLE FOUNDATION f1!5,.:1(!6 OUTLET ON 0 1 '3/0 CU. 1" ROS EMBEDDED IN CONCRETE rolJNDATION WITH MINIMUM 2M ALL AROUND PER AATICLE 250.l'Xl (c). SEE UFE:R GROUND DETAIL @ THE GROUND ELECTRODE MAY ONLY EXTEND OUT OF SLAB IN A. DRY LOCATION. JT MUST EXTEND OUT OF SLAB AT LUST SIX INCHES AND NO MORE THAN 18 INCHES AND THE POINT OF CONNECTION OF THE GROUNDING ELECTRODE CONDUCTOR !S ENCASED IN CONCRETE. EXCEPTION: WHERE THE CONNECTION OF THE GROUNDING ELECTRODE CONDUCTOR IS ENCASED IN CONCRETE. 0 COHNECTION TO ELECTRODE. CONNECT GROUNDING CONDUCTOR TO GROU~ING ELECTRODE WITH LISTED GROUND CL.AMP. SEE C.E.C. 2ro-10. © 20 FT. (6.1 M) OR MORE OF CONTINUOS IJ/0 BY£ COPPER WIRE. . Tl-IE TOTAL RESISTANCE MF:ASUREO BETWEEN THE WI.IN SERVICE GROUND BUS AND THE £ARTH SHALL NOT EXCEED 2e OHMS UNDER ORY GROUND CONomoNS. SEE n.ECTRICAL SP£CFICATIONS FOR "'GROUND TESTS"'. UFER GROUND IH ACCORCWiCE WITH THE 1999 ti.E.C AND 2001 CAl..lf'ORNl4 ELECTRIC CODE (C.E.C.) DRIVEN GROUND I I ' l'\..2·x 4• oouc. FIR N0.1 PRESSURE TREA TfO POST (TYPICAL) CONSTRUCTION SIGN -----------------~~-'-DETAIL© E 12/04/03 REEDCORP ENGINEERING CONSULTING ELECTRICAL ENGINEERS 2061 Business Center Drive, Suite 110 Irvine, CA 92612 (949) 752-1278 FAX: (949) 752-1287 E-MAIL : ee@reedcorp.net N.T.S; DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE ..... N -',., INITIAL OTHER APPROVAL ' •' ,. ' :,1 ff E If.(,~ ,._ +-,: \. .,_ ~· '"-llt.ffl1 i&; f,,f:t/30M ' • ~ , .. ,---+-"!'-"ff'--PULL THROUGH BOND TOGETHER IF METAL CONDUIT ~.,.--REINFORCED CONCETE BOX WITH CONCRETE EXTENSION AS REQUIRED ---12" DEEP GRAVEL SUMP SEE PER SITE PLAN PULL BOX "Z BUIL T11 ;."!</ ~ ~ 3/ l 4-/v,r / I RCE :ti:"3 l EXP, "l J ialar. DATE ' Rfil~jl' l-Lrl~ INSPECTOR DATE ~ CITY OF CARLSBAD I SHE:Ts I ENGINEERING DEPARTMENT 4 CHASE PARK LIGHTING RENOVATION ELECTRICAL DETAILS APPROVEDV.Wl~LIAM ~R P.E. &!<1 $? • 7 le, ~-I).(>(. DEPUTY PUBLIC WORKS DIRECTOR PE 51274 EXPIRES10/30/05DATE OWN BY: PROJECT NO. DRAWING NO. DATE INITIAL CHKD BY: CITY APPROVAL RVWD BY: PKS-03-08 DWG 412-7 042904 , ' "1 0 Q, N 0) 0 0 (S '-. _, '-. 0 rl "" d "' u m 0 0 "' ~ lDff SffllJfflJII IIIIIL P!ll 11' )llll[O !lGIIIIIG, DIC. (SIB POii ..... CAIIOII) ---PIii: -Bl' WflCO -111:.(111"8 mmmo,)-- POLE FOUNDATION SCHEDU'LE FORCES (l(illllUll) CAISSON lffl 110111111 (II) S1111R ('I) 111111CM. (P) KIP-IT KIPS KIPS IIIIIIIIIIR IIIBIIJIIIN'I ll!QI ftlBT 1860-A 43.45 1.023 1.281 30" 10'-0" 1870-A 64.26 1.303 1.558 30" 12'-o,. LS'70-C 111 .27 2.048 2.532 30• 14'-0" POLE IDENTIFICATION -POii PIIIEllll --l!ITllRI IIIRI[ TYPI -(PllroJIIS m CIIOSSARII) IPA A1, A4 11!60-A 2B 4(2+2 16.0 A2, A3 11!60-A 2B 8(2+2/2+2)BB 24.0 Bl, B4 IB70-A 3B 7(4+3} 28.0 B2, B3 IB70-C 4B 14(7+7) 56.0 THIS DRA.1'llrfG m A. COPY OF THI SIGNJID STRUCTURAL llNOINIIZRS CALCULATIONS ,r ,....., • ffl! ~ • UIS 1B 1.020 15'-2" 7'-2" 8'-0" 9.56" 2B 1.840 17'-3" 7'-3" 10·-o· 18.00' 3B 2.670 20'-0" 81-0" 12'-o" 13.38" 4B 3.7IO 22'-0" e·-o· 1•·-0· 15.75' 5B 5.180 23'-11" 7'-11'" 1e·-o· 18.26" 6B 8.020 26'-l" e·-1· 10·-o· 20.56' 7B 11.680 27'-!0" 7'-10' 20' ---o~ 23.75' (Ill POii .,_.Ill! ~ FOUNDATION DETAIL GENERAL NOTES ....... AU. CON!fflWCIION #11 WOIIIIOIWI.., IIWJ. CONP'OIIM ro 1Hl UNfl'tlAW IUILDINB CODE. 2001 EDITION, ,._D :7<1 MPH (EXPOSURE 0) IIE'EREN0t POL£ 1.0C.-:nON DMWlfO ~ AC'1'U\L POU PtAC!M!MY • sm: I.OCl<IION. THE OONTRICIOR IS 801.ELY RDf'ONIIIIU Falt ALL CONSTRUCOON fl'ftOCEDllRES N«> wm CONDm)NS "' THt JOB sot. U DflfPtt PtRttflffl' WWW ~NICl,L wt Pll!PMED B"I' W l!HIIIIIIIM SM DIEGO, ltC .. CW1D AIJGUSf 12", 2003; PN. 2003-0202/48319 M1.0WIL£ \llfflCN. lt'AIIN Cll'ICfN': 140 ~ ,:r 10'..o" 1,114 _.., 11MDE. ALl.0\IHI.! LJ,~ PAMN£ SOI. BOO!IIG PRmUR£: IOO PSF/FJ \IAL.llt'!I !MY llE flCRFASED t/3 FOR WlfO. REl'ERENCE' ctW'f£R 16., SECIION 180U.2.1 MfD T,181.£ 11-1-A OF TI£ 2001 EDITION OF THE CAUF'ORNA 9UI.DING COD[. DE:SIQN SOIL fWW IW .i11E NJ NO'!Ut. olCf1.JM.. ALlCJWMU SOIL PJIIWffliRS MUSf 11£ V!lm!D ON SITE. A REPMSENTA'IM: Of' '1'!SJ1NO; ENOINEERS-9,t,N DtmO, NC., BtWJ. I£ AVAIL.Aa.E Kr TM[ 111,11!': OF 1tlE FOUNMTIDN tm'.IUATION lO 'lof:RFI' TtlE SOL OESION PAfWtl£1ERS AND TO PROYIDE ASSISl'ANCE IF Nff P"°8LEMS /IJlfi IN f'OUNOATION INS!fM.1AllON. DI0001fTERlfG !l0t. FORWmONS 'THAT M.L EQtlR£ SPtellJ. 08IGN 1~.i>~~~~ ''" IF Nff DIICMl¥,NCIES Cit INCOMIIIS'IINCI NUii NMll"I' THE !HDINED OF SOOH DISCREPNfCICI, FOUNDATIONS WILL THl!M BE R£VISED ACCORDINGLY. ALL PIERS AND oot«::RE1E IMCICflLL MIJ9T 8EAA ON NI.) IDNNSJ '1MI, UttOISTURIIED SOIL MJ. !XCAWO'IONS WIT N !'RE! 0, 1.001! SOI. Nit 0[Ml9 l'ltlOlt TO FOUNMTION INSTot.l.J.A'IIOM AND ltlACIM!NT OF OOMCIEE IWlKR.l.. CMING w.y l!E REQUIRl!':D F CASINO OCCURS. l,IJ, IXCAVAllOMS WOST I! I'm OF WA1!R OIi CONCftM SHALL BE PI.Al'.fll W11M A 1RE1i1E PP£ Ill NJ0CJRDN«.:E wmt Ml STNfJMO 3()4.. ~Mir oM,M,~ ~ ,=,,11'!'''1,\',~ "COHCAEl'E &t.CKFIU." BELOW, cottC9'JJ IW!P1 I COltCftEf£ 8'aCFU. 9tWJ.. HM ,. MHNLIM UlJIWffl! C0MPN!:9IM stMNatH ,.T 21 oos or :s.oao PSI. lflt<:W. INSP!CflOtrl or CONCR£l'[ IS NOT RIQUIIED..{3,000 P9I C0NCAEl'E IS SPECIFIED l'DR EAAL'f POLE fJlfCl10N. NOT fOfl STIWCfUltAL D!S1GN Pl.111:POSES) OONCflPI MCKflU. $tW.L ATMIN A NIHINUM SQIENIJl'H Of 2,000 PSI PNORTOPCU!MC'TION. USE Td'E M PORllAND OEM!Nr Oft /IS PECOMMINDED 1h 'H llEOfECHNIQl,L ENGINm. MDC IN ~ Wini .IS1M t-14. (1• IN. #JO. SIZE) HIGREGfflS P'tR ASN t--33, PV,CI COHCIIEJt INM!b'ffll.Y ll'TDI COllflLITION fJf !)(QWA'OON Ml) IMSPECl'ION 1W 1ME «o'l'!CHHICAL ENOINEER, NO Eltt'lAVATIONS !llW..l. BE I.EFT UNPM'l'Ee'IED OR OPOI <MRtrlOHT, CONCR!TE 9tf,\U. I[ PlN%D .. ONE OON11NIJOOS OP!MTION (MO ~ .UNI') WffH !lPECW. [QIJIPMENT 1fflt1 I, t,Wlll,IUM FREEFALL OF 5 FT AltD TO PRE'll£NT CONCREJI FROM Sffffl<INC THE SIDEll DF 1ME EXCA'IATICIM. '4M4.TE TOf' 5 rr. MYfilttrl!S f1X1UltfS MIJSf 1£ I.Ol'.TIO TO IWNTNN 10'-o" tllNIMIM HOJll2:0N'l'N. Cl.£W.NCE FROM ~ OBS1'RVCflON, ~ ., 0 0 0 ~ ;; ~ ti &I i5 Sl ~1~i« ;;,~: oll ~~i ~~~i!l-~ ... ~ ~ ~~ WM \'B'Ri..,';'111'!"""' ~ r..= UG~~Jr\ ..... • 2& UIS (l<R IAJSOO UOlfflNO, I"') f BALLFIELD POLE FOOTING STRUCTURAL CONTACTOR CONFIGURATION & SWITCHING SCHEDULE # of Full Load Contaetor Cont. Pole Fixt. Amps Size (Amps) Zone ID A1 4 10.5 30 1 C1 A2 4 10.5 30 1 C2 A2 4 10.5 30 2 C5 A3 4 10.5 30 2 C6 A3 4 10.5 30 3 C9 A4 4 10.5 60 3 C10 81 7 17.5 30 1 C3 82 7 17.5 30 1 C4 82 7 17.5 30 2 C7 B3 7 17.5 30 2 ca 83 7 17.5 30 3 C11 84 7 17.5 ..)U 3 C12 TLC 208V, 311l _ ...... Handhole Cover Grode Un• BALlA~~CUll BR VOLTAGE SYSTEM M MAX. AMP PHASE RATING Of Of Fl RES fl 1 IRES ..., w 1-6 1 9 JO 480 i 7-12 10-18 60 480 13-20 19-20 109 480 Q. 21 35 :31-52 170 277 1-3 1 5 3S 277 w +-7 e-10 60 277 w 8-12 11-18 109 277 0: 13-20 19-31 175 240 ~ 1 3 1-4 30 240 ..... 5-9 60 240 0: 7-10 10-15 100 240 0 11-18 16-29 175 208 w 1-2 1-4 JO 208 ..J 3-5 5-8 60 " 208 z 6 • 9 13 100 208 iii 9-15 14-23 175 Po\tt c;;o1.1nt l e l l 2 l ER SCHEDULE LUG SIZE WIRE SIZE , 1+-1 0 3 , 1>1--1 0 3 , 1>1--1 0 3 f1 G-300 MCM . 2 0 1 1>1--1 0 1 14 1 0 3 1 1+-1 0 3 " 6-350 MCM • 2 0 1 1>1--1 0 3 1 1>1--1 0 3 1 1>1--1 0 3 (1) 11 -500 •cM ,, OR 2 1-250 MCM 1 14-1 0 3 1 14-1 0 3 1 1>1--1 0 3 (1 1-:500 MCU 3 OR 2 '1-250 MCM • t Number of Remote Equipment Controllere (REC's) 1 Number of Contoctor Cabinets: (1) 24" X 72" Number of 0.0.A. Switches: 3 -Conduit Adaptor Plate Wlth Access Hole, Below Grode (2 Side11) 0 Contactor Summary Qty Size 12 30AMP LlpMlng Zon11 Zone# 1 Rec Relayf 1.1 2 3 Field Type BASEBALL BASEBALL BASEBALL 1.2 1.3 Zone■ 1 2 3 Deecrfptlon Zone 1 Zone 2. Zone 3 Customer Field BASEBALL #2 BASEBALL #1 BASEBALL #3 Musco Potes A1 ,A2,81 ,82 A2,A3,82,83 A3,A4,83,B4 Name EXISTING CONTACTOR CABINET HAS ELEVEN (11) 30A/3P CONTACTORS ANO ONE ( 1) 60A/3P CONTACTOR. CONTRACTOR TO RETAIN MUSCO LIGHTING TO RECONNECT AND REWIRE CONTROL WIRING SYSTEM IN MUSCO CABINETS. CONTRACTOR TO TERMINATE NEW LIGHT POLE CIRCUIT WIRING ONTO CONTACTORS. SWITCHING SCHEDULE-MUSCO 'CONTROL LIN~T~: ® Not To Scale POLE WIRING SYSTEM THREE EJXTURES PHASE A • 2 FIX. PHASE B • 2 FIX. PHASE C • 2 FIX. EQl JR EIXTI JRFS PHASE A • 3 FIX. PHASE B • 3 FIX. PHASE C • 2 FIX. TYPICAL WIRING OF FIXTURES WITH 3• DISTRIBUTION W--hll-o.tall 1-6 Flldurw • 3e,6,/2P -----' 7-12. Fixtur'!MI • 80/\/2P (3 Pole C.B. P~) WIRING SCHEMATIC (Ballast Cc:ibinet) 08@ 08 ENE EJXTURES PHASE A • 3 FIX. PHASE B • 4 FlX. PHASE C • 3 FlX. SIX FIXTURES PHASE A • 4 FIX. PHASE B • 4 FIX. PHASE C • 4 FIX. BALLFI ELD PO LE EQUIPMENT Pote t.1ounthg lo,:,;,.tlon height Al 60' A2-A3 60' A4 60' Bl 70' B2-B3 70' B4 70' CHASE FIELD, CARLSBAD CA MAINTAINED ILLUMINATION BASEBALL $,Bl HORIZONTAL FOOTCANDLES □N PLANE AT Z= 3 LISTING 21. e 28. 9 26,6 es. Fixture Type1 TLC MZ/TLC MZ Infield IJl.:tflelci Polr F'i)(t, llow sl:z:• Eletv. /unit unit Lo.Mp Type1 1500',/ MZ/1500',/ MZ Tnrget Polnts1 25 58 51.67 32.68 60' o· 4 6.4 60' 0' e 12,8 60' o· 4 6.4 LUME?l"ISI 27, 0 39. 6 41. 8 35. 4 26. 5 18, Fite # / Do.te1 Prepo.recl Byi 70' o· 7 11.2 32. 9 45, 6 46. I 38, 9 31. 5 24. 4 19. 0 70' O' 14 22.4 70' o· 7 1L2 30. 6 41. 6 .... 38.0 32, 5 28, 0 23. 5 19. 0 .... 40. 9 42,3 39. 7 35. 7 30.4 26, 6 24. 5 21. 34, 6 48. 0 41:J. ' 48, 1 42, B 33. I 29, 6 29.8 28, 6 43, 5 , .. " 5tl, 5 56, 3 47, a 35. 8 33. 1 35. 4 37, 3 31. 7 44, 1 so. a 6L 7 60. 1 52. 1 40, s J,, ::; 39, o 42. & 34. 2 $,Al 58, 0 66. 4 57, 9 56, 1 54, 1 39, a 33, l".I 35. 4 .,, ~ $. '!', ~ > "' ~ '!', ~ .. .. "' i i, .. Pole loco.tlon dlMenslons o.re rela.tlve to 0,0>4-"eference point 0 COPYRIGHT (Cl 1981,2003 MUSCO SPORTS LIGHTING -Not to oo reproduced In whole or po.rt without the writ- ten consent of Musco Sports Lighting. .. t, ~ .. "' ,q, ,q, " ~ 0 25 155000 102409 / 22-Jul-2003 C Hoy 50' 100' Avero.ge1 Mo.xlMUl'll 67.64 Minl,..uM1 35.42 Avg/Min• 1.459 Mox/Mint 1,910 UG (Aoj pts) 1.483 cv, 0.171 NUl"lber of LuMlno.lrws• • K\./ ConsuMptlon1 1u11:Ave-ro.ge Tilt Fo.ctor1 ,1011111Recovero.ble-Light Loss Fo.ctor-s1 Toto.I Light Loss Foctor<LLF) MAINTAINED ILLUMINATION BASEBALL HORIZONTAL F□DTCANDLES ON PLANE AT Z= 3 45.28 19.05 1,715 2.376 1.515 0.233 22 105.60 0,946 X 0,800 0,756 Infield □utflelol To.rge-t Polnts:1 Avero.ge1 Moxll'IUMI MlnlMuM: Avg/Mini Ma.x/Mln1 UG (Aoj pts) cv, Nul'lber of L1.mlno.lres:1 111 KIJ ConsuMptlon1 25 51.42 66.38 34.12 1.507 1.946 1.586 0,170 11n11Avero.ge Tilt Fnctor1 •••Recovernlole Light Loss Fo.c:tors:1 Toto.l Light Loss Fo.ctor(LLF) MAINTAINED ILLUMINATION BASEBALL HORIZONTAL F□OTCANDLES ON PLANE AT Z= 3 58 32,02 46,08 18.69 1.713 2.465 1.664 0.228 22 105.GO 0,944 X 0,800 0,755 Inflelol Outfield To.rget Poln'ts:1 Avero.ge1 MnxlMuMr MlnlMurti1 Avg/Mlrn Mo.x/Mln1 UG (Aoj pt•l cv, Nul"lloer of LuMlno.lres• • KIJ ConsuMptlon1 25 50.23 59.63 34.51 1.456 1.728 1.555 0.151 58 32.64 47.02 19.54 1.670 2.406 1.578 0.226 22 105.GD SCALE: 1" = 50' 1101<Avero.9e Tllt Fo.ctor-1 0,947 MOH:Recovero.lole Light Loss F o.ctors1 x 0,800 Toto.l Light Loss Fo.ctor(LLF) 0,757 BACK TO BACK (0 O] (4) <!;: ;?l (4) (4) BACK LIGHT POLES A1,M 60' POLE POI F A2 AND A3 60' POLE {OJIO> O ■ O] (_£) 0' O] (7) POLES BJ.64 70' POLE (14) (14) SEVEN (7) FOR FIELD 2, SEVEN (7) FOR FIELD 1 SEVEN (7) FOR FIELD 2, SEVEN (7) FOR FIELD 3 BACK LIGHT BACK LIGHT ......._ __ BALLAST __ __,. PQLE B2 70' POLE CABINETS (TYPICAL) PQLE B3 70' POLE MUSCO POLE CONFIGURAT ~wN,4,.,. 11 AS BUILT" ,f ~ ./ ~ " 1c ;); "' No. 7~1 1' · .. E,p:tr.-.. 7 ,;:!, RCE EXP. c1/;,0l111, & 1l: i t !./,4-)uo ' ' DATE REVIEIJED ~ {el (J !11,'-- !SPECTOR DATE ~ CITY OF CARLSBAD 1 sHE:Ts I 5 ENGINEERING DEPARTMENT CHASE PARK LIGHTING RENOVATION . MUSCO DETAIL"l 10/04/03 '" REEDCORP ENGINEERING A~:l~Ll~ER P.E. ~~ It\, ~0 l•fs 2-17-t>f ~ 0, CONSULTING ELECTRICAL ENGINEERS -DEPUTY PUBLIC WORKS DIRECTOR PE 51274 EXPIRES10/30/05DA1E I 2061 Business Center Drive, Suite 110 C') Irvine, CA 92612 r--"' ~49) 752-1278 FAX: (949) 752-1287 I "' -MAIL : ee@reedcorp.net 0 DATE INITIAL DATE INITIAL DATE DWN BY: PROJECT NO. DRAWING NO. INITIAL CHKD BY: ENGINEER OF WORK REVISION DESCRIPTION OlliER APPROVAL CITY APPROVAL RVWD BY: PKS-03-08 DWG 412-7 '.042904