Loading...
HomeMy WebLinkAboutDWG 514-3A; CT 2017-0005; GRAND WEST; 01-13DATE: Apr 08, 21 11:20am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-01-TITLE.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. O. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. PROJECT LOCATION TLTC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 SECTION B-B SECTION A-A SECTION A-A B SECTION B-B AA PLAN VIEW A A B B B B PLAN VIEW SECTION A-A SECTION B-B A B A PLAN VIEW DATE: Apr 08, 21 11:21am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-02-DETAIL.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. TLTC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 GRAND AVENUE DATE: Apr 08, 21 11:22am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-03-DEMO.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. TLTC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 GRAND AVE.PVT. DRIVEWAYPVT. DRIVEWAY DATE: Apr 08, 21 11:29am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-04-GRADING.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 GRAND AVE.PVT. DRIVEWAYPVT. DRIVEWAY DATE: Apr 08, 21 11:32am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-05-UTL.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. TLTC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 BMP TYPEBMP ID #SYMBOL CASQA NO.DRAWING NO.SHEET NO.(S)MAINTENANCE FREQUENCY BMP TABLE INSPECTION FREQUENCYQUANTITY TREATMENT CONTROL AND 100-YR ATTENUATION FACILITY LOW IMPACT DESIGN (L.I.D.) SOURCE CONTROL HYDROMODIFICATION & TREATMENT CONTROL HYDROMODIFICATION BIOFILTRATION TC-32 426 S.F.MONTHLY MONTHLY-2, 4, 5 N/ASD-12N/A AS-NEEDEDMONTHLYSMART IRRIGATION 1 N/A N/A 7 8 9 10 NEED FOR FUTURE INDOOR/STRUCTURAL PEST CONTROL LANDSCAPE/OUTDOOR PESTICIDE USE: PROVIDE IMP ROOFTOP DRAIN TO PERVIOUS LANDSCAPE AREA, AVOID USE OF UNPROTECTED METALS PLAZAS, SIDEWALKS, AND PARKING LOTS: SWEEP REGULARLY, COLLECT DEBRIS, COLLECT WASTEWATER AND DISCHARGE TO SANITARY SEWER SC-41 SC-41 SC-10 SE-7 SC-43 -- BMP NOTES: PARTY RESPONSIBLE FOR MAINTENANCE: NAME ADDRESS PHONE NO. CONTACT PLAN PREPARED BY: NAME ADDRESS PHONE NO.CERTIFICATION COMPANY SIGNATURE 1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS OR THESE PLANS. 2.NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3.NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 4.NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION AND INSTALLATION. 5.REFER TO MAINTENANCE AGREEMENT DOCUMENT. 6.SEE PROJECT SWMP FOR ADDITIONAL INFORMATION. * CHOOSE FROM THE LIST BELOW FOR COMPLETING THE FIELDS IN THE INSPECTIONS & MAINTENANCE FRENQUENCY COLUMNS: ANNUAL SEMI-ANNUALLY QUARTERLY BIMONTHLY MONTHLY AS NEEDED NONE WEEKLY 1 TIME PER YEAR 2 TIMES PER YEAR 3 TIMES PER YEAR 4 TIMES PER YEAR 11 12 COBBLE SWALES CHECK AND MAINTENANCE (PUMP/VAULT) 2, 4, 5 2, 4, 5 2, 4, 5 2, 4, 5 2, 4, 5 2, 4, 5 EC-10 BIOMONTHLY AS-NEEDED AS-NEEDED AS-NEEDED AS-NEEDEDAS-NEEDED AS-NEEDED AS-NEEDED BIOMONTHLY AS-NEEDED - - - - 1 -- - - - - N/A N/A N/A N/A N/A BIOMONTHLYBIOMONTHLY - 6 WATER QUALITY SIGNAGE SD-13 2, 4, 5 NANA-3 EA -DATE: Apr 08, 21 11:34am by:dmasson FILE: I:\16\16277\PROD\Reports\SWQMP\Exhibits\16277-SS BMP-Final Eng.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. LEGEND TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 DATE: Apr 08, 21 11:41am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-07-TIER2.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. VALLEY STREETSEESHEET3FORDETAILSPLANTBUILDING3000CHILLER TIER 2 CITY STORM WATER POLLUTION PREVENTION PLAN (TIER 2 SWPPP) WEATHER TRIGGERED ACTION PLAN CASQA Designation Construction Activity (BMP) Description Best Management Practice* Erosion Control Sediment Control BMPsBMPs Tracking Control BMPs Non-Storm Water Management BMPs Waste Management and Materials Pollution Control BMPs BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE PROJECT LOCATION TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 GRAND AVE. PVT. DRIVEWAY PVT. DRIVEWAYDATE: Apr 08, 21 11:42am by:dmasson FILE: I:\16\16277\PROD\Construct\GP\16277-GRD-08-TIER2.dwgO. 760.741.3570 www.masson-assoc.com Planning Engineering Surveying 200 E. Washington Ave., Suite 200 Escondido, CA 92025 & A S S O C I A T E S , I N C . M A S S O N F. 760.741.1786 Solved. TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH TRENCH/EXCAVATION PERMIT NO._ _ _ _ _ _ _ _ _ _ _ _ Know what's R DIG ALERT!! TWO WORKING DAYS BEFORE DIG ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS DIG ALERT & GENERAL CONTRACTOR SHALL LOCATE & POTHOLE (AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL CONSTRUCTION BEGINS. REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THE TEMPORARY SHORING OF THIS PROJECT (SHEETS 9-12), AND THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF TEMPORARY SHORING AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, MY RESPONSIBILITIES FOR PROJECT DESIGN. SHORING DESIGN GROUP NAME: ROY P. REED 7727 CAMINITO LILIANA SAN DIEGO, CA 92129 SIGNATURE: PH: (760)586-8121 LEGEND T.O.W. = TOP OF SOLDIER BEAM WALL B.O.W. = BOTTOM OF SOLDIER BEAM WALL (P) = PROPOSED (E) = EXISTING PROPOSED IMPROVEMENTS IMPROVEMENT SYMBOL TEMPORARY SOLDIER BEAM TEMPORARY TIMBER LAGGING SOLDIER BEAM COUNT xDETAIL/SECTION CALLOUTS BY OTHERS = WORK OUTSIDE SHORING SCOPE 3x12 DF#2 TIMBER LAGGING # EXISTING BUILDING 1 2 3 4 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING PROPOSED TEMPORARY SHORING (SEE SHEET SH10 FOR PROFILE) PROPOSED BIO-FILTRATION BASIN 1 (SEE UTILITY PLAN) PROPOSED BUILDING A PROPOSED BUILDING B RIGHT-OF-WAY PROPERTY LINE PROPERTY LINE PROPERTY LINE GRAND AVE. TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 70.00' 60.00' 50.00' "H" 70.00' 60.00' 50.00' T.O.W. = 66.00' B.O.W. = 59.00' T.O.W. = 66.00' B.O.W. = 59.00' 3 SPACES @ 8'-0" O.C. = 24'-0" "D" EXISTING GRADE FINISH GRADE T.O.W. = 66.00' TEMPORARY SOLDIER BEAM (SEE SCHEDULE FOR SIZE) PROPOSED BIO-FILTRATION BASIN NO. 1 PROPOSED RETAINING WALL FOOTING REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 1. SEE SOLDIER BEAM SCHEDULE ON SHEET 11 FOR SHORING ATTRIBUTES. 2. POTHOLE/FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION. 3. REMOVE THE UPPER 3'-0" OF SHORING UPON COMPLETION & BACKFILL OF THE LOWER BIO-RETENTION CONCRETE WALL, FOR PLACEMENT OF CMU BLOCK (SEE SHEET 2 FOR DETAIL). NOTES: PROFILE - LOOKING WEST SCALE: 1" = 4' LEGEND: T.O.W. = TOP OF WALL B.O.W. = BOTTOM OF WALL DESIGNATES 3x12 PRESSURE TREATED LAGGING PROPERTY LINE 6"2 3 4 PROPOSED STORM DRAIN (UTILITY PLAN) PROPOSED BIO-FILTRATION BASIN NO. 1 (SEE UTILITY PLAN) EXISTING STRUCTURE PROPOSED WALL (SEE GRADING PLAN FOR ELEVATIONS) PROPOSED STORM DRAIN (UTILITY PLAN) PROPOSED TEMPORARY SHORING (TYPICAL) 4'-0" PROPERTY LINE 2 1 1 3 TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 EXISTING GRADE (T.O.W., SEE ELEVATION) "H" "D" Dshaft TIMBER LAGGING, TYPICAL (SEE ELEVATION FOR SIZE) 1.5 SACK SLURRY SHAFT BACKFILL (T.O.W. TO B.O.W) 2,500 PSI CONCRETE SHAFT BACKFILL (B.O.W TO PILE TIP) 42" (MIN.) SAFETY CABLE RAILING, PER CAL-OHSA REQUIREMENTS (TYP., AROUND ENTIRE SHORED PERIMETER, SEE 4/SH11) TEMPORARY CANTILEVERED SOLDIER BEAM (TYP.) N.T.S. SOLDIER BEAM, TYPICAL (SEE SCHEDULE FOR SIZE) BOTTOM OF EXCAVATION (B.O.W., SEE ELEVATION) 44" 2" 21" 21" CAL-OSHA GUARDRAIL DETAIL N.T.S. L2x2x3/8 ANGLE IRON ATOP EACH SOLDIER BEAM MEMBER SOLDIER BEAM, TYP. (SEE SCHEDULE) DRILL SHAFT (SEE BEAM SECTIONS FOR BACKFILL MATERIAL) EACH BEAM1/4" LQFK‘:,5(523( ALONG ENTIRE SHORING PERIMETER (TYP.) L=6" NOTES: 1. FIELD VERIFY ALL EXISTING & PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. SEE SOLDIER BEAM SCHEDULE ON SH11 FOR VARIABLES "H", "D", & "Dshaft". PERMANENTLY ENCASED SOLDIER BEAM PLAN DETAIL N.T.S. PROPERTY LINE TEMPORARY TIMBER BLOCK-OUTS PLACED AT INTERIOR FACE OF WALL FOR SOLDIER BEAM REMOVAL. WATER PROOFING & DRAINAGE BOARDS (BY OTHERS) BURN HOLES THROUGH SOLDIER BEAM WEBS FOR HORIZONTAL REBAR (1" DIA. MAX.) SEE ELEVATION FOR SPACING EPOXY COAT ENTIRE BACK FLANGE & 4" OF WEB UPPER 10'-0" ONLY PROPOSED 6" THK. BIO-RETENTION CONCRETE STEM CUT & REMOVE PROTRUDING WEB & FLANGE UPON COMPLETION OF THE PROPOSED STRUCTURE AND/OR AS DIRECTED BY THE STRUCTURAL ENGINEER OF RECORD. FILL ALL VOIDS WITH AN APPROVED NON-SHRINK GROUT ACCORDING TO PROJECT SPECIFICATIONS. FILL VOIDS BEHIND LAGGING LEAN CONCRETETIMBER LAGGING (SEE ELEVATION) BIO-FILTRATION HORIZONTAL REINFORCEMENT (SEE SHEET 2) 6" SOLDIER BEAM SCHEDULE GEOTEXTILE PVC CONNECTOR PIPE SEAL CUT-IN JOINT GEOCOMPOSITE DRAIN PREFABRICATED DRAIN GRATE STRIP WITH DUCT TAPE DRAIN GRATE ISOMETRIC VIEW 3" DIA. WEEP HOLE WITH DRAIN GRATE MID BAY BETWEEN SOLDIER BEAMS “$%29(%277202) NEW WALL FOOTING (SEE ISOMETRIC VIEW) 1 2 4 NOTE: EPOXY COATING IS NOT REQUIRED FOR SOLDIER BEAMS #1 OR 4. 6" 7.84" REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 6" TEMPORARY SHORING CROSS SECTION ALONG WEST PROPERTY LINE N.T.S. NOTES: 1. FIELD VERIFY ALL EXISTING & PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION. 2. SEE SOLDIER BEAM SCHEDULE ON SH11 FOR VARIABLES "H", "D", & "Dshaft". 70.00' 60.00' 50.00' 70.00' 60.00' 50.00' PROPOSED BIO-FILTRATION BASIN 1 (SEE UTILITY PLAN) TEMPORARY SOLDIER BEAM ABANDON IN PLACE WHEN COMPLETE (SEE SCHEDULE FOR SIZE) BLOCK OUT SOLDIER BEAM WITHIN PROPOSED CONCRETE STEM (SEE 2/SH11 & SHEET 2 SECTION) REMOVE UPPER 2'-0"- 3'-0" UPON COMPLETION OF CONCRETE STEM FOR REMAINDER OF CMU BLOCK WALL INSTALLATION (SEE DETAIL ON SHEET 2) EXISTING GRADE PROPERTY LINE PL 3 TL TC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021 7727 CAMINITO LILIANA SAN DIEGO, CA 92129, (760)586-8121 GENERAL NOTES 1. CONSTRUCTION PLANS AND CALCULATIONS CONFORM TO THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODE. 2. TEMPORARY SHORING CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE OF CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL-OSHA). 3. HEAVY CONSTRUCTION LOADS SUCH AS CRANES, CONCRETE TRUCKS OR OTHER LOAD SURCHARGES NOT IDENTIFIED IN THE "DESIGN CRITERIA", WILL REQUIRE ADDITIONAL ANALYSIS & FURTHER RECOMMENDATIONS. NOTIFY THE SHORING & SOILS ENGINEER PRIOR TO INSTALLATION. 4. ALL TEMPORARY SHORING ELEMENTS DEPICTED WITHIN THESE DRAWINGS ARE LIMITED TO A MAXIMUM SERVICE LIFE OF ONE (1) YEAR. AT THE END OF THE CONSTRUCTION PERIOD, THE EXISTING OR NEW STRUCTURES SHALL NOT RELY ON THE TEMPORARY SHORING FOR SUPPORT IN ANYWAY. 5. AN UNDERGROUND SERVICE ALERT MUST BE OBTAINED 2 DAYS BEFORE COMMENCING ANY EXCAVATION. 6. THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS DURING CONSTRUCTION. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL INSPECTION SERVICES, TESTING & NOTIFICATIONS. 8. ALL PERMITS SHALL BE PROCURED AND PAID FOR BY THE OWNER OR GENERAL CONTRACTOR. 9. ALL MONITORING PROVIDED IN THESE PLANS HEREIN, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. TEMPORARY SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING & PROPOSED FEATURES, AS PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL CONTROL & COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY VARIATIONS TO THE ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK. 11. THE GENERAL CONTRACTOR OR OWNER SHALL LOCATE ALL EXISTING UTILITIES AND STRUCTURES PRIOR TO EXCAVATION AND THE INSTALLATION OF SHORING. 12. THE GENERAL CONTRACTOR SHALL CONFIRM THAT THE PROPOSED SHORING DOES NOT CONFLICT WITH FUTURE IMPROVEMENTS PRIOR TO INSTALLATION. 13. THE GENERAL CONTRACTOR SHALL PROVIDE MEANS TO PREVENT SURFACE WATER FROM ENTERING THE EXCAVATION OVER THE TOP OF SHORING BULKHEAD. 14. INSTALLATION OF SHORING AND EXCAVATION SHALL BE PERFORMED UNDER CONTINUOUS OBSERVATION AND APPROVAL OF THE GEOTECHNICAL ENGINEER AND AUTHORITY HAVING JURISDICTION. 15. ALTERNATIVE SHAPES, MATERIAL AND DETAILS CANNOT BE USED UNLESS REVIEWED AND APPROVED BY THE SHORING ENGINEER. 16. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFY CONDITIONS AT THE JOB SITE AND TO CROSS-CHECK DETAILS AND DIMENSIONS WITHIN THE SHORING PLANS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER PERTINENT DRAWINGS BEFORE PROCEEDING WITH CONSTRUCTION. 17. ALL GRADING & EXCAVATIONS PERFORMED FOR THE PROPOSED TEMPORARY SHORING AND/OR PROPOSED STRUCTURE, IS OUTSIDE THE SCOPE OF SERVICES PROVIDED HEREIN. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONDUCTING SITE EARTHWORK IN CONFORMANCE WITH GEOTECHNICAL RECOMMENDATIONS. MATERIAL SPECIFICATIONS STRUCTURAL STEEL 1. STRUCTURAL STEEL (WIDE FLANGES) SHALL CONFORM TO THE REQUIREMENTS ASTM A-572 OR ASTM A-992 (GRADE 50). 2. MISCELLANEOUS STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-36, ASTM A-572 (GRADE 50) OR ASTM A-992. 3. TRENCH PLATES (LAGGING) SHALL CONFORM TO THE REQUIREMENTS FO ASTM A-36. STRUCTURAL & LEAN CONCRETE A. STRUCTURAL CONCRETE: 1. STRUCTURAL CONCRETE (DRILL SHAFT TOE BACKFILL) SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500PSI AT 28-DAYS. 2. CONCRETE MIX SHALL BE IN ACCORDANCE WITH 2016CBC & ACI 336 TO MEET THE FOLLOWING: A. MAXIMUM 1-INCH HARDROCK CONCRETE CONFORMING TO ASTM C-33. B. TYPE II NEAT PORTLAND CEMENT CONFORMING TO ASTM C-150. C. SLUMP FOR WET HOLE 6"-8" & 4"-6" DRY HOLES. B. LEAN CONCRETE (SLURRY) 1. LEAN SAND SLURRY MIX SHALL CONTAIN A MINIMUM OF 1.5 SACKS TYPE II CEMENT PER CUBIC YARD. TIMBER 1. TIMBER LAGGING SHALL BE ROUGH SAWN DOUGLAS FIR LARCH NO. 2 OR BETTER. 2. TIMBER LAGGING SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA U1 USE CATEGORY 4A. WELDING 1. ELECTRIC ARC WELDING PERFORMED BY QUALIFIED WELDERS USING E70XX ELECTRODES OR CONTIUOUS WIRE FEED. 2. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING. EPOXY PAINT (AS REQUIRED) 1. EPOXY COATING: SOLDIER BEAMS SHALL BE 2-COATS BITUMASTIC COAL-TAR EPOXY, APPLIED FOR A TOTAL DRY FILM THICKNESS OF 16 MILLS. ALL STEEL SURFACES SHALL BE BLAST WITH SSPC-SP 10 (NEAR WHITE) BEFORE COATING IS APPLIED. SHORING INSTALLATION PROCEDURE 1. FIELD SURVEY DRILL HOLES & SHORING ALIGNMENT ACCORDING TO WALL DIMENSIONS & DATA SHOWN OR AS APPROVED BY THE SHORING ENGINEER. 2. DRILL VERTICAL SHAFTS TO THE EMBEDMENT DEPTH AND DIAMETERS SHOWN. ALLOWABLE PLACEMENT TOLERANCE SHALL BE 2" IN OR 2" OUT OR AS OTHERWISE AUTHORIZED BY THE SHORING ENGINEER. 3. INSTALL SOLDIER BEAMS ACCORDING TO THE DETAILS & SPECIFICATIONS SHOWN IN PLAN. IF NECESSARY, CASING OR OTHER METHODS SHALL BE USED TO PREVENT LOSS OF GROUND OR COLLAPSE OF THE HOLE. 4. START EXCAVATION AFTER CONCRETE HAS CURED FOR A MINIMUM OF (3) THREE DAYS. 5. INSTALL LAGGING BETWEEN INSTALLED SOLDIER BEAMS IN LIFTS NO GREATER THAN 4'-0" OR AS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. 6. BACKFILL ALL VOIDS BEHIND LAGGING WITH LEAN CONCRETE AS SPECIFIED IN THE DETAILS HEREIN. 7. REPEAT STEPS 6-7 UNTIL BOTTOM OF EXCAVATION IS REACHED. 8. ALL EXCAVATIONS SHALL BE LAGGED AND BACKFILLED BY THE END OF EACH WORKDAY. NO EXCAVATIONS SHALL BE LEFT EXPOSED OR WITHOUT BACKFILL. STATEMENT OF SPECIAL INSPECTIONS VERIFICATION AND INSPECTION 1. Verify use of required design mix 2. Inspection of concrete placement for proper application techniques. 3. Material verification of structural steel a.For structural steel, identification markings to conform to AISC 360. b. Manufacturer's report 4. Inspection of welding a. Multipass fillet welds 5. Material identification of timber a. Identification of preservative VERIFICATION AND INSPECTION ITEMS (OTHER) 6.Observe drilling operations and maintain complete and accurate records for each element. 7.Verify placement locations and plumbness, confirm element diameters, lengths, embedment into bedrock (if applicable). Record concrete and grout values. CONTINOUS PERIODIC CBC REFERENCE 8. Verify excavations are extended to the proper depth. 1904.2.2 2303.1.8.1 MONITORING 1. MONITORING SHALL BE ESTABLISHED AT THE TOP OF SOLDIER BEAMS SELECTED BY THE ONSITE GEOTECHNCIAL REPRESENTATIVE AND AT INTERVALS ALONG THE WALL AS CONSIDERED APPROPRIATE. 2. THE GENERAL CONTRACTOR SHALL PERFORM A PRECONSTRUCTION SURVEY INCLUDING PHOTOGRAPHS & VIDEO OF THE EXISTING SITE CONDITIONS. 3. MAXIMUM THEORETICAL SOLDIER BEAM DEFLECTION IS 1/2-INCH. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) EXCEEDS THIS LIMIT, ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED AND INVESTIGATED BY THE SHORING ENGINEER FOR FURTHER ACTIONS (AS NECESSARY). DESIGN CRITERIA 1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED IN THE FOLLOWING GEOTECHNICAL REPORTS: A. ADDENDUM 01, TEMPORARY SHORING RECOMMENDATIONS PROPOSED TWO TRIPLEX TOWNHOME CONDOMINIUMS 972 & 988 GRAND AVENUE CARLSBAD, CALIFORNIA PREPARED BY: CTE, INC. DATED JANUARY 27, 2020 2. SOIL DESIGN PRESSURES A. PASSIVE EARTH PRESSURE = 300PSF/FT (3,000PSF MAX) B. AT REST PRESSURE = 42PSF/FT (CANTILEVERED, LEVEL) C. TRAFFIC LIVE LOAD = 100PSF (UNIFORM) REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. TLTC DocuSign Envelope ID: 77D32402-04C3-4949-845C-2364D4A19240 4/12/2021