HomeMy WebLinkAboutPD 2020-0027; 3481 SEACREST DRIVE SLOPE REHABILITATION; 4 BLOCK HIGH KEYSTONE WALL STRUCTURAL CALCULATIONS; 2020-10-20Use menu item Settings > Printing & Title Block to set these five lines of information for your program. Title :3481 Seacrest Carlsbad Page : 1 Job # :Dsgnr:tp Date: 20 OCT 2020 Description.... 4 block high keystone wall This Wall in File: Z:\01 Mammoth\4182 SIERRA BUSINESS PARK brian bularsky\documents\Wall Calcs\block RetainPro (c) 1987-2018, Build 11.18.07.31 Segmental Retaining Wall with Geogrids Code: NCMALicense : KW-06055653License To : TRIAD/HOLMES ASSOC Thumbnail Criteria Wall height (retained height), ft 2.67 Backfill slope 3:1 Backfill angle 18.3 Embedment 0.5 = = = = Soil data External Soil, Phi_e 28 External soil density (In situ), pcf 129 Internal Soil, Phi_i 28 Internal soil density, pcf 129 Wall Soil Friction Angle 19 K_a(Horiz)0.42 = = = = = = Stability Overturning ratio 8.74 Sliding ratio 2.53 Overturning moment, ft-lbs 360 Resisting moment, ft-lbs 3,148 Total lateral/sliding force, lbs 309 Sliding Resistance, ft 783.38 Total vertical force, lbs 1,473 Base length, ft 4.00 Eccentricity on base, ft 0.11 Effective base length, ft 3.78 Soil bearing pressure, psf 389.30 Allowable soil bearing, psf 1,500.00 Soil Bearing Ratio 3.85 = = = = = = = = = = = = = Use menu item Settings > Printing & Title Block to set these five lines of information for your program. Title :3481 Seacrest Carlsbad Page : 2 Job # :Dsgnr:tp Date: 20 OCT 2020 Description.... 4 block high keystone wall This Wall in File: Z:\01 Mammoth\4182 SIERRA BUSINESS PARK brian bularsky\documents\Wall Calcs\block RetainPro (c) 1987-2018, Build 11.18.07.31 Segmental Retaining Wall with Geogrids Code: NCMALicense : KW-06055653License To : TRIAD/HOLMES ASSOC Loading Dead load, psf 0 Live load, psf 0 Seismic Design Kh 0.00 = = = Segmental block data Vendor selection 'Keystone Retaining Wall Systems' Vendor web address 'www.keystonewalls.com' Block selection type 'Standard' Block height, in 8.00 Block depth, in 18.00 Offset per block, in 0.00 Batter angle 0.00 Wall weight, psf 180.00 Hinge height, ft 0.00 = = = = = = = = Geogrid material Vendor Selection 'Mirafi Geogrid' Vendor web address 'www.mirafi.com' Geogrid type 'Miragrid 2XT' LTDS 1046.13 Factor of safety 1.50 LTADS 697.42 Peak connection equation 1850 + 0.04N Peak connection maximum 2027 Serviceability connection equation 1000 + 0.1N Serviceability connection maximum 1427 = = = = = = = = = = Use menu item Settings > Printing & Title Block to set these five lines of information for your program. Title :3481 Seacrest Carlsbad Page : 3 Job # :Dsgnr:tp Date: 20 OCT 2020 Description.... 4 block high keystone wall This Wall in File: Z:\01 Mammoth\4182 SIERRA BUSINESS PARK brian bularsky\documents\Wall Calcs\block RetainPro (c) 1987-2018, Build 11.18.07.31 Segmental Retaining Wall with Geogrids Code: NCMALicense : KW-06055653License To : TRIAD/HOLMES ASSOC Block Layer Height above base Tension Embed Vert S. F. Seismic Wall Analysis Table: Le NServPeak Connection StaticDecInFt Required Extent, Ft* 4 8" 2.672' 1 1 8" 0.67 143 1036.00'1242.9 1.88 360 4.87 4.00 Base 0" 0.000'480 * Extent of geogrid referenced from the front face of wall, FT Summary: Resisting / Overturning Resisting Moments Distance, ft Moment, ft-lbs Wall 0.75480 360 Reinf. earth 2.75 2,365860 3.18Sloped 423133 2.75 0Dead load 0 02.75Live load 0 3,148 309 1.16 360 0 1.75 0 Total 1,473 Item Force, lbs Overturning Moments 0 1.75 0 Item Force, lbs Distance, ft Moment, ft-lbs 0 0.00 0 Earth 0 0.00 0 Surcharge, DL 0 00.00 Surcharge, LL Seismic, Wall Seismic, Reinf. Seismic, Sloped soil Seismic, Exterior 0.000 0 Total 309 360 Overturning Ratio 8.74 ASSUMPTIONS AND CRITERIA USED 1. References used include Design Manual for Segmental Retaining Walls, 2nd Edition, and Segmental Retaining Walls – Seismic Design Manual, 1 st Edition, both by NCMA. 2. Blocks are all same size and uniform offsets (batter) for full wall height. 3. Coulomb earth pressure theory used for earth pressures and failure plane angle. 4. Refer to geotechnical report for backfill material, compaction, and other design data and recommendations. 5. Cap blocks if used are above the retained height and are neglected in this design. 6. Geogrid LTDS and connection values for block vendors obtained from ICC Evaluation Service (ES Legacy Reports) or as provided by vendors. Since these may change or be updated, verification of values is recommended. 7. Block sizes obtained from vendors’ literature and may vary with locality. 8. Geogrid layers are equally spaced vertically, all same length, and laid horizontally. 9. Average weight of block and cell infill assumed to be 120 pcf. 10. See vendor web sites (on input screen) for more information and specifications. 11. Design height is limited to 16 feet or 24 blocks, whichever is less. Contact vendor for higher designs or special conditions. 12. Seismic design is per Seismic Design Manual cited above. Also see Methodology/Seismic Design in User’s Manual. 13. Vendor specifications or project specifications, whichever is most restrictive, to be followed for construction procedures. 14. Add notes and details for proper drainage. 15. See User’s Manual Design Example #10 for methodology and sample verification calculations. 16. Final design responsibility is with the project Engineer-of-Record. I I I I I I I I I I I I