Loading...
HomeMy WebLinkAboutCT 82-04; PALOMAR OAKS II; RETAINING WALL DESIGN PARAMETERS; 1988-08-31SO U THERN CAL I F ORNI A SO IL A ND TES T ING , INC . 6280 RIVEROALE ST. SAN OIEGO, CALIF". 92120 • TELE 280·432 P.O. BOX 20627 SAN OIEGO. CALIF", 921 20 6 7 8 £NTC:RP R IS C: ST. ~ C'." O N D I O 0, C A L t r 9 2 0 2 ~ Augus .. 31, 1988 Birtcher Construction 27822 El Laza Road Laguna Niguel, California 92656-3989 SCS&T 8821057 Report No . 3 SUBJECT: Retaining Wall Design Paraneters, West Oaks Way, Palomar Oaks II, Carlsbad, California. REF'EREICE: Suwlenentary Geotechnical Investigation, Palomar oaks II Business Park, Southern California Soil and Testing, Inc., Report No. 1, dated April 26, 1988. Gentlenen: In accordance with the request of Chris Christakos, Structural Engineer, this report has been prepared to present retaining wall design paraneters for the retaining wall planned along the southside of West oaks way. The prop::,sed wall will have a height of about ten feet and will have a backslope of about two horizontal to one vertical or flatter. The soils within a depth of five feet of the fOWldation have been renoved and replaced as carpacted fill. The backcut for the renoval operation exposed a stiff colluvium. Based on our observations and grading recormerx:lations, it is our opinion that the unrestrained cantilever retaining wall should be designed with an active soil pressure of 53 powxis per cubic f oot. The wall should have sufficient weep holes and gravel behind the wall to prevent hydrostatic pressure build-up. The gravel drain should be at least 12 inches wide am should extend to within two feet of the ground surface at the top of the SOUTHERN CALIFORN I A S O IL AND TEST I NG, I N C . SCS&T 8821057 Augus t 31, 1988 Page 2 wall. The gravel should be separated from t he adjacent soil by a Geofabric Filter material. The foundation for the retaining wall may be designed using an maxim.mt allowable soil bearing pressure of 4000 pounds per square foot. The coefficient of friction bet~n the concrete footing and soil may be taken as O. 35. A passive pressure against the side of the footing and key can be assuned to be 350 p:Junds per square f(X)t per foot of depth. The friction and passive resistance may be conbined, however, when doing so, the friction value should be reduced by one-third. All backfill for the retaining wall should be nonexpansive and should be coopacted to at least 90 percent relative corrpaction. If you should have any questions after reviewing this rep:Jrt, please do not hesitate to contact this office. This ORX)rtunity to be of professional service is sincerely awreciated. Respectfully sul::mitted, SCUIHERN CALIFORNIA SOIL & TESTI~, IOC. 4fl<L.ltdt:r Charles H. Christian, R.G.E. #00215 OC:nw cc: (3) Sul::mitted (3) Chris Christakos Engineering