HomeMy WebLinkAboutDWG 431-7; 36753; SCADA INTEGRATION; 01-07CONSTRUCTION PLANS FOR
ENCINA BASIN WATER RECLAMATION PROGRAM, PHASE II PROJECT
(PROJECT NO. 36753)
(SWRCB PROJECT NO. C-O6-39O3-3OO)
.,•'-6s•-v u a . ...
-!t ~ ~
>;,: "' ~.... ~, ..
",fl WA,~V.
CARLSBAD MUNICIPAL WATER DISTRICT
CARLSBAD, CALIFORNIA
BOARD OF DIRECTORS
CLAUDE A. II BUD II LEWIS -PRESIDENT
MATT HALL -VICE PRESIDENT
ANN J. KULCHIN -DIRECTOR
MARK PACKARD -DIRECTOR
NORINE SIGAFOOSE -DIRECTOR
RAYMOND R. PATCHETT
EXECUTIVE MANAGER
LLOYD HUBBS
PUBLIC WORKS DIRE CTOR
'MER WILLIAM E. PLUM
DEPUTY CITY ENGI NEER
JUNE 2005
' ltid
BLACK & VEATCH o. CS7 87
p. 09/30/06
Corporation
Los Angeles, California
. ~) oS
DATE INITIA_
ENGINEER OF WORK Rt VISION
-
-------
------
-
DATE I\IITIAL
LJLSCRIPTION OHl[R APPROVAL
APPENDIX-A
"AS BUILT '1
f"'.E. EXF·. DATE
REVIE\JFTI RY:
INSPECTOR DATE
SI l[[T CITY OF CARLSBAD[SHEE~ G-1 [NGIN[[RING DEP.ARTME"NT 1 OF 7
-
IMPROVEMENT PLANS FOR:
SCADA INTEGRATION
TITLE SHEET
APPROVED ~ , -::::> h WI __ IAM E. PLUMMER
~-.7.. -~-~-($ --------
PE 28176 C:XP: 3-31 -06 JcYIJ I Y Cl I Y cNC;(NccR UA lE
DWN DY KBV PROJ[CT NO. DRAWING NO. DATE INITA_ CHKD BY: 'fl" I 4.31-7 CITY APPROVAL RVWD BV AK ,_l _l cl,_)
VICINITY
0 CEA N's ID E~4 =1t;;'s\,_, __ ,.\-,-~--....._...,_ ____ -r, -----
1
- - - - -
--------·-···-------- - - -. . . . . . . . . . -- - - - - - -
-------------··-. - - - -.. " . . . . . . . . . - - - -- --- -- - - - ---------------- - - -
--------·-p--A-· ·c•· ·1·F-r-c,. - - --. -. -. . . . . . . ' . . -. . . -- - - - - -. . . . -. - - -. - - - - ---_·. i< OCEAN ·_ ... ·_·_·----- ----
- - - - - - -
VICINITY MAP LEGEND
MAP
AVE
NOT TO SCALE
VISTA
I
I
l~~-
LI ___11 -----
1
I
I
•L -,
I
I
I
®I
I
J r
(T) ·-·
(2)
RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING
RECYCLED WATER PUMP STATION AT CARLSBAD WRF JOINT USE FACILITY ·-
(J) TWIN D RECYCLED WATER PUMP STATION
/--
( 4)
@)
(6)
(!_)
ra\ '-~)
(9\ _ '/
(jO) -~
~-i)
BRESSI RECYCLED WATER PUMP STATION
CALAVERA RECYCLED WATER PUMP STATION
FARADAY PRESSURE REDUCING STATION
MAHR RESERVOIR
RESERVOIR C
AVENIDA ENCINAS PRESSURE REDUCING STATION
LA COSTA PRESSURE REDUCING STATION
MEADOWLARK WATER RECYCLING FACILITY
~j') CORINTHIA I MELROSE FLOW METERING STATION
NOTE: FOR SPECIFIC SITE LOCATIONS NOT SHOWN ON THIS SHEET, CONTACT OWNER FOR REFERNECE DRAWINGS.
LOCATION MAP
c\fOT TO SCALE
SHEET INDEX
G-1 TITLE SHEET
FOR RESERVOIR
\ / ---------. DIRT ROAD ,-\-_ / \\--~
\~ ,
\ RESERVOIR C \
•
♦
---~-i':t:,::Q NCHO CARL~J
,, . GOLF COURSE I
/1 /
_JI \ / I ,J
VICINITY AND LOCATION MAPS AND SHEET INDEX
LEGEND AND ABBREVIATIONS
C
G-2
I -1
I-2
I-3
I-4
I-5
SCADA SYSTEM FUNCTIONAL BLOCK DIAGRAM
INSTALLATION AND PANEL ELEVATION AND DETAILS
INSTALLATION AND PANEL DETAILS
APPENDIX-A
Bu l~ T //
r.E. __
CARLSBAD OPERATIONS BUILDING RFVfF\JFD BY,
JNSf-'lC I LR UA l
I S~EET I 1C ITY OF C A.RLS BAD SI l[[TS ~ I ENGINFFRING [JFPARTMFNT ; 2 OF 7
l---t----t-----------f----l---f--~---1
t---t-----+-----------r-------l---+-----1 IMPROVEMENT PLANS FOR:
SCADA INTEGRATION
. -----------r--~'---+-----+---1
i
ESS1 nrll
{. .ct.®
VICINITY AND LOCATION MAPS
AND SHEET INDEX
- -..
Ar':'RO_VfD _ /..2(_ WIL. LIAM E PLU'AM[R
. CS718 f---+----+-----------r------+-----+-' --1 ~!:.if-i-., ~ -~ .. ,11:.~~--'4-(,-t2£
~~e----+----1 f-'l 281 /6 EXr: 3-31-06 DErUTY CITY E~GINEER D~.T[
p. 091301 BLACK & VEATCH
CO r p Or 8 ti On l--c-)A=TE,--+-,IN=,c=1AL-+--------------f-f-D=AT=[=i=-IN-_1"i,_L-+-. _DA_n:_· ~· IN_IT_IAL_, ~~~oBiv·_K_B.V-=! PROJECT NO. DRAWING NO.
l , Los Angeles, California [NGIN[rn or WORK ~E:\/ISION DESCRIPTION CITY APPROVAL RVWD BY: AK , 36 7 :<3 4,31 7
' ~ ~-l'___ ________ _J ___ _..L __________ _lo:'..'.'.Tl.::::lrn::.._:A::_:PP::.:_:RO-:.:.:_VA::.:_L L.....:....:...:..:...::__..:::..1..'.:::.::::::::::::'.::=====--===========:::'..'.:::=====::'.J
GENERAL INSTRUMENT SYMBOLS
FIELD MOUNTED INSTRUMENT
INSTRUMENT MOUNTED ON
FACE OF PANEL
INSTRUMENT MOUNTED BEHIND
OR INSIDE OF PANEL
INSTRUMENT MOUNTED ON
FACE OF LOCAL PANEL
INSTRUMENT MOUNTED BEHIND
OR INSIDE OF LOCAL PANEL
SINGLE INSTRUMENT HOUSING CONTAINING
lVv'O (OR MORE) INSTRUMENTATION FUNCTIONS
CONTROL INTERLOCK FUNCTION, SEE
SCHEMATICS AND SYSTEM SPECIFICATIONS
FOR SPECIFIC FUNCTION
TAG NUMBERS AND ADDITIONAL DESIGNATIONS
/ FIRST LETTER
//~ .. /--SUCCEEDING LETTERS
r TRC-'
\~-11-----NUMBER AFTER DASH (-1, -2, ETC) DENOTES
1 -MULTIPLE DEVICES USED IN IDENTICAL
\ DUPLICATE SYSTEMS.
\ A LETTER AFTER THE LOOP NUMBER (31A, 31B, ETC)
\ IS USED TO DISTINGUISH MULTIPLE SIMILAR DEVICES
\ IN THE SAME INSTRUMENT LOOP.
I ~---LOOP DESIGNATION NUMBER
--p-a ---SEE INSTRUMENT
( ', FUNCTIONAL DESIGNATIONS
\ 1 AND ABBREVIATIONS.
"-...._ __ / 2"
·-~-PANEL REFERENCE NUMBER AS FOLLOWS:
CUP= CHEMICAL UNLOADING PANEL
------
VCP1 = FILTER VALVE CONTROL PANEL (FILTERS 1 & 2)
VCP2 = FILTER VALVE CONTROL PANEL (FILTERS 3 & 4)
F = FILTER PLC (PLC F) ENCLOSURE
T3 = TO\I\ER/111/ELL NO. 3 PLC (PLC T3) ENCLOSURE
TAG NUMBERS
MEANINGS OF IDENTIFICATION LETTERS
--r·--------------... ===----------
l:t: FIRST LETTER w r-------~-------
~ MEASURED OR
INITIATING MODIFIER
VARIABLE !---+--------+------------.
READOUT OR
PASSIVE
FUNCTION
A ANALYSIS ALARM
SUCCEEDING LETTERS
OUTPUT
FUNCTION
r----t----------r---------1 c-------+------
BURNER. USER'S CHOICE USER'S CHOICE
B COMBUSTION
MODIFIER
USER'S CHOICE
f-------------+---------+----------j
C CONDUCTIVITY
(ELECTRICAL) r--t---~-------,--------.,
D DENSITY (MASS)
OR SPECIFIC
GRAVITY
DIFFERENTIAL
CONTROL
PRIMARY ELEMENT E VOLT AGE (EMF) --+-----
F FLOW RATE RATIO (FRACTION) +-----------jr------------
G USER'S CHOICE f----+------------t------GLASS
H HAND (MANUALLY HIGH
INITIATED)
CURRENT
(ELECTRICAL) f----+--~------
f---------+---------+---·------------j
INDICATE
----------+ --------r-
J
~
K
L
M
POWER SCAN ---·----------------r---------------
TIME OR TIME-TIME RATE CONTROL STATION
SCHEDULE OF CHANGE
-------,--------
LEVEL f-_L_IG~T_(PILOT) --+--------
MOISTURE OR
HUMIDITY
MOMENTARY
f----1---------+-----------
N
0
USER'S CHOICE -----
USER'S CHOICE
USER'S CHOICE USER'S CHOICE --
ORIFICE
.. -~-----,
LOW
MIDDLE OR INTER-
MEDIATE
USER'S CHOICE
(RESTRICTION)
----------1-----------p PRESSURE OR POINT {TEST
Q
VACUUM CONNECTION) ----i--------~-----·--.. ·----1------------j
QUANTITY INTEGRATE OR INTEGRATE OR '
TOTALIZE TOTALIZE
R RADIATION
f-------~ -
RECORD OR PRINT f----+---···--· --~------------,------------------
s
T
u
V
SPEED OR
FREQUENCY
TEMPERATURE
MUL T!VARIABLE
VIBRATION
W I WEIGHT OR FORCE
SAFETY
---------
+--------+-----------
SVVITCH
i------------------------
TRANSMIT
MUL TIFUNCT10N MULTIFUNCTION
VALVE, DAMPER,
OR LOUVER --------+--
WELL
MULTIFUNCTION
·---------
X UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED
y
z
EVENT, STATE,
OR PRESENCE
POSITION,
DIMENSION
--
-----------~---
------j-------
RELAY OR COMPUTE
DRIVE, ACTUATOR
OR UNCLASSIFIED
FINAL CONTROL
ELEMENT
DIGITAL SYSTEMS
INTERFACE SYMBOLS
NOTE: REFER TO DETAILED SYSTEM SPECIFICATIONS FOR
FUNCTIONAL DESCRIPTION. ALSO SEE 1/0 SCHEDULES FOR
COMPLETE INPUT AND OUTPUT LISTINGS.
DIGITAL SYSTEM 1/0 INTERFACE
DIRECTION OF ARROW DENOTES
WHETHER INPUT OR OUTPUT. A FILLED
ARROW DENOTES ANALOG 1/0; AN UNFILLED
DENOTES A DISCRETE 1/0. DEPENDING ON
THE APPLICATION. A SINGLE ARROW OF A
PARTICULAR 1/0 TYPE MAY SIGNIFY ONE OR
MULTIPLE SIMILAR 1/0 POINTS. CONSULT
THE PLC INPUT/OUTPUT SCHEDULE TO
DETERMINE EXACT 110 POINT QUANTITIES.
PROGRAMMABLE LOGIC CONTROLLER
SYSTEM FUNCTION BLOCK.
"CB" NUMBER REFERS TO SOFTWARE CONTROL
BLOCK DESCRIPTION IN THE SPECIFICATIONS.
GENERAL NOTES
1. IN GENERAL, THE P &ID SYMBOLS AND DEVICE IDENTIFICATIONS
ARE BASED ON INSTRUMENT SOCIETY OF AMERICA, STANDARD
PRACTICE ISA-S5.1 (1988). SOME MODIFICATIONS, ADDITIONS,
ANO ALTERATIONS HAVE BEEN MADE AS NEEDED TO ACCOMMODATE
THE PROJECT REQUIREMENTS
2. ADDITIONAL CONTROL AND INTERLOCK REQUIREMENTS VVHICH CAN
BE MORE CLEARLY ILLUSTRATED ON SCHEMATIC DRAWNGS HAVE
BEEN OMITTED FROM THE P & ID DRAV\llNGS. SOME PROCESS ITEMS,
SUCH AS EQUIPMENT ISOLATION VALVES, BYPASS LINES, ETC.
VVHtCH ARE NOT CRITICAL FOR AN UNDERSTANDING OF THE
INSTRUMENTATION FUNCTIONS HAVE ALSO BEEN OMITTED.
:3. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND
ABBREVIATIONS MAY NOT BE UTILIZED ON THIS SPECIFIC PROJECT.
4. PIPING AND EQUIPMENT LEGEND APPLIES TOP & ID SHEETS
ONLY ANO MAY DIFFER FROM LEGENDS FOR OTHER SHEETS
FUNCTION DESIGNATIONS AND ABBREVIATIONS
K
-K
F(X)
>
<
X
I
COND
DO
F
LEL
MCC
□2
INSTRUMENT DESIGNATIONS
GAIN OR ATTENUATE (INPUT:OUTPUT)
GAIN AND REVERSE
ADD OR SUM (ADD AND SUBTRACT)
SUBTRACT (DIFFERENCE)
EXTRACT SQUARE ROOT
DIVIDE
CHARACTERIZE SIGNAL
HIGH-SELECT
LOW-SELECT
MULTIPLY
INTEGRATE (TIME INTEGRAL)
METHANE
CHLORINE RESIDUAL
CARBON DIOXIDE
CONDUCTIVITY
DISSOLVED OXYGEN
FLUORIDE
LO\I\ER EXPLOSIVE LIMIT
MOTOR CONTROL CENTER
OXYGEN (PURITY)
pH CELL
TURB TURBIDITY
PIPE MATERIAL ABBREVIATIONS
A-20 ALLOY 20
CPVC CHLORINATED POLYVINYL CHLORIDE
CS CARBON STEEL
PVC POLYVINYL CHLORIDE
OTHER ABBREVIATIONS
CSU CHANNEL SERVICE UNIT
DSU DATA SERVICE UNIT
HAND SWITCH DESIGNATIONS
HOA
LR
oc
00
LOR
OOA
OCR
OOR
OSCA
HAND-OFF-AUTO
LOCAL REMOTE
OPEN-CLOSE
ON-OFF
LOCAL-OFF-REMOTE
ON-OFF-AUTO
OPEN-CLOSE-REMOTE
ON-OFF-REMOTE
OPEN-STOP-CLOSE-AUTO
TRANSDUCER & CONVERTER DESIGNATION
E VOLTAGE
FSK FREQUENCY SHIFT KEYING
H HYDRAULIC
I CURRENT
p PNEUMATIC
PD PULSE DURATION
PF PULSE FREQUENCY
R RESISTANCE (ELECTRICAL)
EXAMPLE: 1/P = CURRENT TO PNEUMATIC
TRANSDUCER
POWER SUPPLY ABBREVIATIONS
AS AIR SUPPLY
ES ELECTRIC SUPPLY
GS GAS SUPPLY
HS HYDRAULIC SUPPLY
NS NITROGEN SUPPLY
SS STEAM SUPPLY
WS WATER SUPPLY
AS '>--POWER SUPPLY SOURCE LABEL.
USED ONLY WHERE NECESSARY
TO HELP CLARIFY AN INSTRUMENT
OR SYSTEM FUNCTION.
LINE SYMBOLS PROCESS DEVICE SYMBOLS UTP UNTWISTED PAIR VALVE AND GATE ACTUATOR SYMBOLS
'
-
---------' I
- - -------- - -
I
' --<:~> c:~>-
-0--0-··-
MAJOR PROCESS PIPING OR FLOW CHANNEL
SECONDARY PROCESS PIPING
MISCELLANEOUS PIPING
SHADED OR LIGHT LINE WEIGHT DENOTES
EXISTING OR FUTURE PIPING AND EQUIPMENT
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
PNEUMATIC SIGNAL
ELECTRICAL DIRECTION ARROW
SIGNAL CONNECTION POINT
SIGNAL LINE GOING
TO ANOTHER SHEET
SIGNAL LINE FROM
ANOTHER SHEET (MATCH LETTERS)
FLOW ARROW FOR PROCESS PIPING
PROCESS LINE GOIING
TO ANOTHER SHEET
MATCH SHEET NO. IDENTIFIER
MATCH LINE NO.
PROCESS LINE COMING
FROM ANOTHER SHEET
PROCESS LINES CROSSING (NOT CONNECTED)
INTERNAL SYSTEM SIGNAL LINK
(SOFTWARE OR DATA LINK)
R
I
_ ____,, 'e------
1 I
{-~-· -· ~-... __ __;
---rn-
-----fTTl-
DIAPHRAGM SEAL
ANNULAR TYPE
DIAPHRAGM SEAL
PURGE OR FLUSHING DEVICE
POSITIVE DISPLACEMENT TYPE FLOWMETER
PRIMARY FLOW ELEMENT: ORIFICE PLATE
PRIMARY FLOW ELEMENT: VENTURI TUBE
PRIMARY FLOW ELEMENT: FLUME
PRIMARY FLOW ELEMENT: \M:IR
PRIMARY FLOW ELEMENT: TURBINE OR PROPELLER-TYPE
PRIMARY FLOW ELEMENT: PITOT TUBE
PRIMARY FLOW ELEMENT: ELECTROMAGNETIC
OR TRANSIT-TIME ULTRASONIC
DOPPLER TYPE ULTRASONIC
FLOW SENSOR
PRIMARY ELEMENT: ROTAMETER
DRAIN
THERMAL DISPERSION TYPE FLOW ELEMENT
N
sz·
8
f -
------------
FLOW CONTROL OR ISOLATION GATE
VALVE: GLOBE, GATE, OR OTHER IN-LINE
TYPE NOT OTHERWISE IDENTIFIED
VALVE: EXISTING OR FUTURE
VALVE: THREE WAY
VALVE: FOUR WAY
VALVE: BUTTERFLY, DAMPER OR LOUVER
VALVE: ROTARY BALL TYPE
VALVE:CHECK
VALVE: PLUG TYPE
VALVE: DIAPHRAGM
VALVE: PRESSURE RELIEF
VALVE: VACUUM BREAKER
PULSATION DAMPENER
STRAINER
CALIBRATION COLUMN
vs
p:(AJ3
M
PUMP
VS DENOTES: VARIABLE SPEED
PUMP (CHOPPER)
SCREW (LIFT) PUMP
PROGRESSING CAVITY PUMP
MIXER
... PROPORTIONING OR
METERING PUMP
MOTOR
RING DIFFUSER
WYYYYYYYYYYYYYYYYYYYYYSI TRUCK WEIGH SCALE
IC HOSE CONNECTION
f
p
41
~
cp
~
y
y
C?
NO
SYMBOL
DIAPHRAGM
DIAPHRAGM WITH POSITIONER
PRESSURE-REDUCING VALVE,
SELF-CONTAINED
PRESSURE-SUSTAINING VALVE,
SELF-CONTAINED
AIR CYLINDER
SOLENOID
AIR-OIL CYLINDER
ELECTRIC MOTOR
HYDRAULIC CYLINDER
MANUALLY (HAND) OPERA TED
THE FOLLOWING ADDITIONAL
DESIGNATIONS MAY BE UTILIZED
ADJACENT TO SOME VALVE OR
GATE SYMBOLS
NC NORMALLY CLOSED
FC FAILS CLOSED
FO FAILS OPEN
FIP FAILS IN LAST POSITION
---
APPENDIX-A
"AS BUILT"
P.E. ___ _ EXP. ____ _ DATE
REVIEWED BY:
INSPECTOR DATE
fsHml CITY OF CARLSBAD l----+----+-------------------+----+----+---1----1 L_i:1___j ENGINEERING DEPARTMENT
l----+----+-------------------+----+---+---1----1
SHEETS
3 OF7
11lf'ROVEMENT PI.IIN:1 FOR
SCADA INTEGRATION
INSTRUMENTATION & CONTROL DRAWING
LEGEND AND ABBREVIATIONS ~,~, D ~,"l{:'K"tf &% i -.... <> ~;(, · 1\ APPROVED (! '""' 1 1AM E. PLUMMER
iiocS7187 I'll -·~--+:;.~;;;e;..h"""_.'l"l.. ____ {,-'-•QS * /'P-09130/06 * BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE
"' !CJ,~ A> C I OWN BY: I PROJECT NO. I DRAWING NO. ~':"~""""m,.L;e;SfO""» '<ft;~ o r p o r a I o n DATE 1N1T1AL DATE INITIAL DATE 1N1T1AL cHK □ BY:
OF c,c1G C. [1.l oS L ____ L_o_s_A_n_g_e_1e_._· c_a_,;_,o_,_"i_a ____ _LE_NG_1_NE_E_•_o_•_w_o_•<-1.. ____ R_E_v_1_s_1o_N_D_E_s_c_R_1P_T_1_o_N ____ _J~O~T~H-E-:::_-•::.-A::P~P~R-O'::..-V:.:A;L~~~~c-1_T_Y_-A_-'-P_P~R-O---V--A~L:L.:: ~R=V=W=D==B=Y"'-=:'-="'::=:::=:::=:::'::':::...::====3=6=7=5=3===::'.:~=4=3=1=-7=:::::'...J
• •
• •
• PLC-PS-RW
RECYCLED WATER PUMP
STATION AT
CARLSBAD WRF JOINT USE
FACILITY
(NOTE 4)
•
• •
• • PLC-PS·T
TWIN D RECYCLED WATER
PUMP STATION, RWPRV
STATION & PWPRV STATION
•
• ,,0,,UBBBSBBB§BEt aouu<>□□□□aooou □ c
!
I
I
I
I
I
I
I
I
,...C'!...._ - - - - -_.., LL
-:::i r_:gggg,:g~i888~ l"I ciOc,c,c,oc,c,co""""'"'] I r-!!." ~" ,::_,-, •.:.,:• --~, c.:;_, "~ ~ :;:J I
I I I I I I I I I I
I I I I
I~ ·+-+-t-t-+-+-+ l•I --r---T '-[!,--- - - - --,, r
PLC-RES-I/
MAHR RESERVOIR
(FLOW ONLY)
(NOTE 3)
( DDDD """')
OMNI-DIRECTIONAL
ANTENNA
( SPREAD-SPECTRUM
"MASTER" RADIO ~=i
DIRECTIONAL
YAGI
ANTENNA
HOT STANDBY REDUNDANT
CONTROLS SYSTEM 110 SERVERS
•
!
I I
KVM SWITCH
C=::JsPREAD•SPECTRl/!t
"REI/OTE" RADIO
•
•
•
• PLC-RES-C
RESERVOIR C
TO DIAL-UP TELEPHONE
r-----l►SERVICE FOR REI/OTE ACCESS
AND ALARM PAGING
•
•
WORKSTATION COMPUTER
(TYP.) RUNNING
MONOERWARE INTOUCH
• •
• PLC-PS-B •
ic •••• =)r--t ________ il _/ •
• J-~R~I~:~ 3~:1~ ,,, ~~"
"" LlC• □□ D □ □'1110 l'] rJ(j •
BRESSI RECYCLED
WATER PUMP STATION
• •
• • PLC-PS-C
CALAVERA RECYCLED
WATER PUMP STATION
FARADAY PRESSURE
REDUCING STATION
(NOTE 1)
RTU-PRV-C
LA COSTA PRESSURE
REDUCING STATION
(NOTE 1)
' 1( IHH "=")
I
I
ASED-LINE CIRCUIT BRIDGE
(BY TELEPHONE SERVICE
PROVIDER)
1( •••• =)1
MODEM •
• PLC·M
MASTER PLC
• •
•
CONTROLS SYSlEM
DATABASE SERVER #1
(\
I/
·••~ CATEGORY 5e DR 6
UT/> CABLE (TYP.)
CONTROLS SYSTEM
DATABASE SERVER #2
0
0
LEASED-L.INE CIRCUIT BRIDGE 1 • u0u ~ ~ ~ [i ~ ~ 0
" " -§ ~ •
(BY TELEPHONE SERVICE /----------------'---(,,,, =)f---""""""""""'"'" "" I
PROVIDER) MODEM
AVENIDA ENCINAS
PRESSURE REDUCING
STATION
(NOTE 1)
ANALOG VG LEASED-LINE
TELEPHONE SERVICE
(TYPICAL)
' ~--------------------------
ETHERNET O ::: IJl,)lJL)LJIJLJL)I
. . SWITCH I
PLC-OPT
NOTE 2
'----------------,
E (]iiiiiD
I I
LASER REPORTS PRINTER
RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING
NOTES:
1: EACH PRV SITE IS PROVIDED WITH OPTO 22 SNAP IO AND MODEM
PRE INSTALLED. CONTRACTOR IS TO COORDINATE WITH OWNER AND TELCO
LEASED LINE PROVIDER TO COMPLETE PROGRAMMING OF RTUs AND INSTALLATION.
OF MODEMS. MODEMS SHALL BE BLACKBOX MODEM 3600.
2: OPTO 22 SNAP-LCM4 LOCAL CONTROLLER TO BE INSTALLED WITH M4SENET-100
ETHERNET CARD AND SNAP-PS5 POWER SUPPLY TO MATCH EXISTING STANDARD.
3: MAHR PLC BY OTHERS. CONTRACTOR TO PROVIDE MODEM AND SCADA GRAPHICS.
4: PLC-PS-RW SUPPLIED AND PROGRAMMED BY OTHERS.
APPENDIX-A
"AS BUil T"
P.E. __ _ EXP. ___ _ DATE
REVIEWED BY:
INSPECTOR DATE
l---+---+-----------------+--~l----=c====c===J-:==::::::::';::::===========::::;-;:=:::::::::::::-1 ISHEE'r] CITY OF CARLSBAD SHEETS
l-----+----,1-------------------+---+---+---+--_., ~ ENGINEERING DEPARTMENT 4 OF 7
l----!--+-----------------!l----+--+----+-----1
JMPROVEMENT PLANS !'OR:
SCADA INTEGRATION
INSTRUMENTATION & CONTROL DRAWING
D 1-----+---if---------------if---+--+----+----l SCADA SYSTEM FUNCTIONAL BLOCK DIAGRAM -..... APPROV~O • ~ E. PLUMMER
l-----+----,l-------------------+---+---l-----1------ll.,P."4~~~~~~~~, ..... ~es...~~'./:::-.;2'!!W!aM~•-·~~,:i..---G-~-d5 BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE
C I I OWN BY: PROJECT NO. DRAWING NO.
l O r p O r a O n DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: '). .,s L-----L-os_A_n_g_e_1e_•_• c_a_li_fo_rn_ia ____ _._E-NG-I-NE_E_R_oF_w_o_R_K..1... ____ R_E_V_IS_I_O_N_D_E_S_C_R_IP_T_I_O_N ____ ..J..o_T_H_ER_A_P_P_Ro_v_A_L_.__c_rr_v_A_PP_R_ov_A_L..J.._R_VWD __ B_Y_: ________ 3_6_7_5_3 _____ 4_3_1_-_7_.....J
i ..
' '
'
lTEII
A
8
= ~--
i
•
2"X2' WIREWAY
' ~
IT]
\ \\
PUMP STATION PLC/TELEMETRY
_PANEL LAYOUT
!IIITERIAL LIST
DESCIIIPTION
NEMA Type 4X, ata.1nlua ateel enclosure JNasuring :JS•x30"x12",
thrH-point latch1ng, padlockable handl■, and backp■nel.
QFI dual utilitv outlet.
w1th
C Feed through terldn■1 blocks1 aepar■t1on barrtera, and' Ju.per b■rs.
D Fused termin■l block wtth blown fuse 1nd1c■tor (size ■3 needed}.
E 120Vac DIN rail ""unted relavtter11in■l block -SPST.
F 24Vdc DIN rail IIOUfrtltd relay/t.,.lld.nal block· SPST.
8 120V■c DIN r■tl aounted rel ■vttermtn■l block -DPDT.
H ,,,.ch■ntc■l door awttr.h f Intrusion).
l Fluorescent ltaht wJth Nnu■l switch.
J Surg■ protection deyic•.
K 24Vdc. 100W power aunnJ 11.
L 750VA UPS.
#OTES;
1. NOT ALL DEVICES AMY 8E SHOWN
2. ALL DIMENSIONS ARE FOR REFERENCE ONLY
3. COMPONENT PLACEMENT FOR REFERENCE ONLY
4. ALL INTERNAL INSTRUMENT AND COIIPONENT DEVICE 'lfIRINO SHALL 8E AT LEAST 16 Allll.
ANALOG CIRCUITS SHALL BE 16 Atm TWISTED AND SHIELDED PAIRS RA.TED FOR AT LEAST
300 VOLTS. ANALOG CIRCUITS SHALL BE SEPARATED FllOII AC POWER CIRCUITS.
5. PANEL FABRICATOR SHALL WIRE THE IIIELL PLC PANEL AS SHOWN ON SCHEMATICS. IN
ADDITION, THE PANEL FABRICATOR SHALL 'lfIRE ALL PLC I/0 SIGNALS TO THE TERMINAL BLOCKS.
6. THIS DRAWING DETAILS THE INSTALLATION AND CONSTRUCTION OF A TYPICAL PUIIP STATION PLC
PANEL. FOUR OF THESE PUMP STATION Pf.C PANELS WILL BE REQUIRED FOR THE TWIN D, BRESSI,
CAlAVERA ANO RECYCLED WATER PUMP STATIONS.
7. CONSTRUCTION OF THESE PANELS SHALL COIIPLY WITH 2003 NATIONAL ELECTRICAL CODE.
8. THE LEASED LINE PHONE EQUIPMENT SHALL 8E SUPPLIED AND INSTALLED BY SYSTEM SUPPLIER.
9. RElA Y TERMINAL BLOCKS SHOWN FOR REFERENCE ONLY. ACTUAL RE'LAY REQUIREMENTS NEED TO BE
FIELD DETERMINED BASED ON FIELD WIRING IN EACH INDIVIDUAL Pf/MP STATION TERMINATION
CABINET INSTALLED BY OTHERS.
10. TELEPHONE SERVICE CABLE AND CONDUIT TO BE PROVIDED AS SPECIFIED IN SECTION 13500.
11. COORDINATE CONDUIT SIZE AND NUAf8ER OF CONDUCTORS WITH CONTRACTOR.
12. DRAWING SHOWN FOR REFERENCE ONLY. CONSULT EWA EFFLUENT EQUALIZATION AND CARLSBAD IIRF
JOINT USE FACILITIES ELECTRICAL DRAWINGS FOR FURTHER DETAIL. DRAWINGS AVAILABLE FRO/I
THE 01111/ER.
PLC/TELEMETRY PANEL
"'
"' -" 0 -,,
"' --"
[~ ~i
., .. -" " "' ---"
TYPICAL PUMPING STATION
PLC/TELEMETRY PANEL ONE-LINE
(<CfESSI~ . "t.~ ' . '
"
ST AJNLESS STEEL
ENGRAVED "RTU-
NAMEPLATE
CWPBE~
72"
(M AX)
,-NEMA 12 ENCLOSURE
HOFFMAN OR EQUAL I'\
-
11 De
I
\ 36"
'MAX1
\
b
i
•
. .
1 1 '
I
'
'
i
'
i
'
'
1r
I(
24• DEEP
(MAX)
~---INCOMING POWER FUSE BLOCK
•
.
•
ETHERNET
PATCH PANEL
ETHERNET
NETI/VORK SWITCH
MODEM JI
MODEM JI
PLC RACK WITH PROCESSOR,
POWER SUPPLY, ETHERNET
COMMUN/CA TJONS CARD AND I l/0 CARDS AS REQUIRED
~I/
60"
(APPROX)
SEPA
OPTO 22 SNAP-LCM4 CONTROLLER
WITH POWER SUPPLY,
EHTERNET COMMUNICATIONS
CARD AS REQUIRED
WAY WTTH DfVIDER TO
RATE POWER AND ~Lo\lJRE
NET WORK CABLING
EXTERIOR VIEW INTERIOR VIEW
RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING
COMMUNICATION ENCLOSURE
NO SCALE
-------------------------~---~---~-------,~------~
J
EXISING
RIO
CABINET
IRRIGATION
OONTROLLER
TERMINAL
JUNCTION
BOX
C-------,
0
' I
' ' ' ' ' ' ' ' ' ' ' ' '
.. !:;;
I
------------
RECYCLED WATER PUMP STATION AT CARLSBAD WRF JOINT USE FACILITY
ELECTRICAL ROOM
NO SCALE (NOTE 12)
APPENDIX-A
"AS BUil T"
PE EXP, DATE
REVIEWED BY:
INSPECTOR DATE
~ CITY OF CARLSBAD SHEETS
50F 7 -3 ENGINEERING DEPARTMENT
IMPHOV[MJ,:NT PLANS FOH
SCADA INTEGRATION
INSTRUMENTATION & CONTROL DRAWING
NSTALLATION AND PANEL ELEVATION DETAIL!
APPROVED I':, """'AME, PLUMMER .i, .:-_ ~ G-,-M l No. CS7187 * E,p, 09130/06 * BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE
<I',> "'~ ## "< \ •
OWNBY:
I I
PROJECT NO. DRAWING NO, Corporation DATE INITIAL
c,~~ lSi ~' \\, 0 ~ DATE INITIAL DATE INITIAL CHKD BY: Los Angeles, California REVISION DESCRIPTION 36753 431-7
OF cAc'1 \:, ENGINEER OF VVORK OTHER APPROVAL CITY APPROVAL RVWDBY:
C :e
c,, (i)
~A
...... <,.) .....
I .......
2' -0"
END CAPS~
n----.
1· NEMA 4X
315 STAINLESS STEEL
--'
12" MIN
NO SCALE
~
C ~
~
' "' ., ~ ~ ~ ,.
" ~
<o '
'
I
PLC I I RADID
12V DC LEVEL CHARGE TRANSMITTER CONTROLLER
I FUSES I
BATTERY BATTERY
(16" DEEP)
v \_ TO SENSOR JI
"' TO ANTENNA ___/
\_ TO
SOLAR
PANELS
I UNISTRUT 316 STAINLESS
STEEL CHANNEL WITH
CLOSURE STRIPS (TYPICAL)
✓3/4'' GROUT Al..L AROUND -(TYPICAL)
'
==
NOTE 2 4·6/8" EXPANSION _ _/
ANCHORS PER BASE
PLC PANEL MOUNTING DETAIL
TYPICAL FOR: RESERVOIR C
-3!4"C, TSP CABLE PER
r UPNISTRUT 316 STAINLESS STEEL
OST BASE (TYPICAL)
PROVIDE ELECTRICAL\ MFR. REQUIREMENTS
CONDUITJUNCTION BOX 1 (WOTE 10)
FOR LEVEL SENSOR. r,::;=n::::=, TD PLC
1--~----'_J~ •1-_______ _;,---:.,_r_~
•
~ ... 31'-0" UNIT "C" j ~ RESERVOIR
SUBMERSIBLE
r--LEVEL SENSOR I WITH WEIGHTS
I I I </
RESERVOIR C
LEVEL INSTRUMENT
INSTALLATION DETAIL
NOTES:
15' -0"
1. THE CENTERLINE OF ANTENNA ELEVATION SHALL BE 35' ABOVE GRADE.
PLC
2. PANEL DIMMENSIONS ARE A MINIMUM, THE SYSTEM SUPPLIER SHALL PROVIDE
PANElS SIZED AS REQUIRED FOR ALL EQUIPMENT SPECIFIED.
3. ATTACH CABLE EVERY 42" WITH STAINLESS STEEL HARDWARE. LEGS SHALL
NOT BE WELDED OR DRILLED. PORCELAIN INSULATORS TO SEPARATE GROUND
FROM LEG AND STAINLESS STEEL HARDWARE.
4. WELD BASE AND SUPPORT AS REQUIRED FOR ANTENNA LOCATION.
5. CADWELD JOINT AND #2/0 GROUND CONDUCTOR INSTALLED PER ANTENNA AND/OR
TOWER MANUFACTURER RECOMMENDATIONS. CONTRACTOR SHALL ALSO GROUND
RADIO ENCLOSURE
6. MINIMUM BEND RADII SHALL BE STRICTLY OBSERVED FOR ANTENNA FEEDLINES.
7. ALL PENETRATIONS SHALL BE SEALED TO BE WATER TIGHT
8. THE UNIT "C" RESERVOIR LEVEL TELEMETRY STATION IS SOLAR POWERED AND
THEREFORE IS NOT PROVIDED WITH A RELAY WHICH INDICATEDS THE LOSS OF
UTILITY POWER.
9. INSTALL ANTENNA .MAST ON EXISTING STRUCTURE.
10.INSTAlL CONDUIT FROM THE PLC CABINET TO THE RESERVOIR UNDERGROUND.
EXPOSED CONDUIT FROM THE BOTTOM OF THE RESERVOIR TO THE LEVEL PROBE
AND THE ANTENNA SHALL BE INSTALLED ALONG THE SAFETY LADDER IN A NEAT
MANNER.
GRADE-~
SHIELo--
0
0
___ HELIAJ< CABLE
~-GROUND STRAP
ANDREW TYPE 204989
WATERPROOF GROUND
STRAP ASSEMBLY AFTER
INSTALLATION
------#2/0 GROUND
TYPICAL HELIAX GROUNDING DETAIL
NO SCALE
ROHN TYPE 250 TOWER -
NOTE 9
NOTE 5 / _ __/
NOTE 3
----------5 I B " X 8 '
GROUND ROD WIRE
JOINT SHALL BE CADWELD
I / \/ 1\ I I I'
I I 1/ / I \
/
NOTE 4
--WALKWAY I
DATA CABLE
CARLSBAD OPERATIONS BUILDING MOUNTING DETAIL
NO SCALE
ROOF
a@
2" x1 /8" BAR STRAP
3" OR SMALLER PIPE
1 4" CLEAR
2"x1/8" STRAP--
1/2" GALV BOLT
AND EXPANSION
ANCHOR
D D
VERTICAL PIPE SUPPORT
NO SCALE
MAST HEIGHT TO
BE DETERMINED BY
CONTRACTOR. SEE
SPECIFICATIONS
FOR ANTENNA
HEIGHTS PER LOCATION.
DIRECTIONAL
YAGI ANTENNA
(ORIENTATION NOT
ANTENNA MAST
(MOUNTED PLUMB)
NECESSARILY AS
SHOWN)-------+-+-+-+-+-<
GROUND WIRE
CADWELD JOINT
SUPPORT CABLE PER MANUFACTURER'S
RECOMMENDATION, OR EVERY 3' MINIMUM.---+-'
MAINTAIN AT LEAST MANUFACTURER'S
RECOMMENDED MINIMUM BEND RADIUS
#2 COPPER
HANDRAIL
VERTICAL------..
SECTION
SEAL END OF CONDUIT WITH
WATERPROOF SEALANT AND CAP
MAST EXTENSION
TO PROVIDE 60"
LIGHTNING
PROTECTION CONE
HELIX CABLE
ANTENNA
FEEDLINE
GRADE
.______, 5/8" X 8'
GROUND ROD WIRE
JOINT SHALL BE CADWELD
RESERVOIR C ANTENNA MOUNTING SECTION
NO SCALE
NOTE:
D=DISTANCE FROM WALL
AS REQUIRED.
RESERVOIR C
TANK ROOF
APPENDIX-A
"AS BUil T"
P.E. ___ EXP. ____ _ DATE
REVIEWED BY:
INSPECTOR DATE
~CTTY OF CARLSBAD >----+----1--------------------+----t---+---<f---.1 ~ ENGINEERING DEPARTMENT
1----+---+-------------------+----t----t----tf---l
SHEETS
60F7
IMPROVEMENT PLANS FOR-
SCADA INTEGRATION
INSTRUMENTATION & CONTROL DRAWING
INSTALLATION AND PANEL DETAILS
BLACK&VEATCH
~-~---~-~-os
PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE
OWNBY: PROJECT NO. DRAWING NO.
431-7
Corporation
Los Angeles, California
DATE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DATE INITIAL DATE INITIAL
OTHER APPROVAL CITY APPROVAL
CHKDBY:
RVWDBY: 36753
----------------------·---------------------
I I
l OFFICE
--
OFFICE
NEW SCADA
WORKSTATION
AND PRINTER ~
RECEPTION CENTER
/
r
a
OFFICE
-':-EXISTING LIGHTING
PANEL ( NOTE 1)
-
0
I
I • 24"
• I
/-
/ 1,,/
,,--
I I
□ /-
I I /
I I )
-
~
~ ~
E"JE"l ~~ ~E::5
E::::l E5 E"JE"l == == == ES§s §3§5
ETHERNET LAN SWITCH
ADJUSTABLE EQUIPMENT
BRACKET
MONITOR SHELF
WITH KEYBOARD
DATABASE SERVER #1
DATABASE SERVER #2
1"C-2#12 r-J
#12GND
MULTIPURPOSE RACK
CHATSWORTH 24 "X7' STANDARD RACK
OR HERGO STANDARD 24" RELAY RACK
(OPEN DESIGN)
' .
•
',
' . •~
.,,,-M-' ~ROUTE CABLING THROUGH EXISTING
I -------;;;::;>/ COVERED WIRE TRENCH ~ < ) r // ----++~NEW SERVER LOCATION ":,,_ ,/, {;J ,1/~~/,,/,/:· .// ----------,-_1 INSTALL POWER CABLING TO UPS AND ,, ,/ (ij. Ov:< (,,., ,/ i EXISTING BUILDING LIGHTING PANEL ,,, ' ,(] . \
' \ '
'~,· \\ ·,.,,,.,~ INSTALL OMNI DIRECTIONAL ANTENNA
' \ ,__ PER MOUNTING DETAIL ON SHEET I-4
. d::, : , ....... J]~-----EXISTING ANTENNA
1
1 '\__ UNINTERRUPTIBLE POWER SUPPL y (UPS) FOR l NEW SERVERS AND COMMUNICATION ENCLOSURE
-COMMUNICATION ENCLOSURE
FOR MASTER PLC AND OPTO 22
SNAP-LCM4 CONTROLLER
NOTES: APPENDIX-A
1 • CONTRACTOR SHALL COORDINATE WITH THE CITY
TO TIE INTO A SPARE EXISTING 12OVAC CIRCUIT. /; AS BUlL I 11
PE_ EXP. DATE
REVIEVED BY,
TN~PF[T□R DATE
~ CITY C)F' CARLSBAD SHEETS
- ---ENGINEERING DEPARTMENT 7 OF 7 5
IMPROVEMENT PLANS r'OH:
SCADA INTEGRATION
•
CARLSBAD OPERATIONS BUILDING
19® '
-----.~PP ROVED -@ WILLIAM E. PLUMMER
6-~-06' &416; t: ,,,,.,
l<
BLACK&VEATCH PF 281 ifi EXP . . 3-31-Clb UU'L IY CIIY E_NGINEER DATE
-OWN BY KBV PROJE_CT NO. DRAWING NC. Corporation n,'I.TF INITIAi DATE INITIA.L l")ATF INITIAi CHKLJ ~Y: Los Angeles, California REVISION DESCR PTION I---- . -------36753 431-7 I:. \IIJINttJ>; 01-WOt-,;K Cl l Y APPROVAL RVWD BY AK OTHER APPROVAi
C :e ..... G')
~A ...... w
....II
I
""