Loading...
HomeMy WebLinkAboutDWG 431-7; 36753; SCADA INTEGRATION; 01-07CONSTRUCTION PLANS FOR ENCINA BASIN WATER RECLAMATION PROGRAM, PHASE II PROJECT (PROJECT NO. 36753) (SWRCB PROJECT NO. C-O6-39O3-3OO) .,•'-6s•-v u a . ... -!t ~ ~ >;,: "' ~.... ~, .. ",fl WA,~V. CARLSBAD MUNICIPAL WATER DISTRICT CARLSBAD, CALIFORNIA BOARD OF DIRECTORS CLAUDE A. II BUD II LEWIS -PRESIDENT MATT HALL -VICE PRESIDENT ANN J. KULCHIN -DIRECTOR MARK PACKARD -DIRECTOR NORINE SIGAFOOSE -DIRECTOR RAYMOND R. PATCHETT EXECUTIVE MANAGER LLOYD HUBBS PUBLIC WORKS DIRE CTOR 'MER WILLIAM E. PLUM DEPUTY CITY ENGI NEER JUNE 2005 ' ltid BLACK & VEATCH o. CS7 87 p. 09/30/06 Corporation Los Angeles, California . ~) oS DATE INITIA_ ENGINEER OF WORK Rt VISION - ------- ------ - DATE I\IITIAL LJLSCRIPTION OHl[R APPROVAL APPENDIX-A "AS BUILT '1 f"'.E. EXF·. DATE REVIE\JFTI RY: INSPECTOR DATE SI l[[T CITY OF CARLSBAD[SHEE~ G-1 [NGIN[[RING DEP.ARTME"NT 1 OF 7 - IMPROVEMENT PLANS FOR: SCADA INTEGRATION TITLE SHEET APPROVED ~ , -::::> h WI __ IAM E. PLUMMER ~-.7.. -~-~-($ -------- PE 28176 C:XP: 3-31 -06 JcYIJ I Y Cl I Y cNC;(NccR UA lE DWN DY KBV PROJ[CT NO. DRAWING NO. DATE INITA_ CHKD BY: 'fl" I 4.31-7 CITY APPROVAL RVWD BV AK ,_l _l cl,_) VICINITY 0 CEA N's ID E~4 =1t;;'s\,_, __ ,.\-,-~--....._...,_ ____ -r, ----- 1 - - - - - --------·-···-------- - - -. . . . . . . . . . -- - - - - - - -------------··-. - - - -.. " . . . . . . . . . - - - -- --- -- - - - ---------------- - - - --------·-p--A-· ·c•· ·1·F-r-c,. - - --. -. -. . . . . . . ' . . -. . . -- - - - - -. . . . -. - - -. - - - - ---_·. i< OCEAN ·_ ... ·_·_·----- ---- - - - - - - - VICINITY MAP LEGEND MAP AVE NOT TO SCALE VISTA I I l~~- LI ___11 ----- 1 I I •L -, I I I ®I I J r (T) ·-· (2) RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING RECYCLED WATER PUMP STATION AT CARLSBAD WRF JOINT USE FACILITY ·- (J) TWIN D RECYCLED WATER PUMP STATION /-- ( 4) @) (6) (!_) ra\ '-~) (9\ _ '/ (jO) -~ ~-i) BRESSI RECYCLED WATER PUMP STATION CALAVERA RECYCLED WATER PUMP STATION FARADAY PRESSURE REDUCING STATION MAHR RESERVOIR RESERVOIR C AVENIDA ENCINAS PRESSURE REDUCING STATION LA COSTA PRESSURE REDUCING STATION MEADOWLARK WATER RECYCLING FACILITY ~j') CORINTHIA I MELROSE FLOW METERING STATION NOTE: FOR SPECIFIC SITE LOCATIONS NOT SHOWN ON THIS SHEET, CONTACT OWNER FOR REFERNECE DRAWINGS. LOCATION MAP c\fOT TO SCALE SHEET INDEX G-1 TITLE SHEET FOR RESERVOIR \ / ---------. DIRT ROAD ,-\-_ / \\--~ \~ , \ RESERVOIR C \ • ♦ ---~-i':t:,::Q NCHO CARL~J ,, . GOLF COURSE I /1 / _JI \ / I ,J VICINITY AND LOCATION MAPS AND SHEET INDEX LEGEND AND ABBREVIATIONS C G-2 I -1 I-2 I-3 I-4 I-5 SCADA SYSTEM FUNCTIONAL BLOCK DIAGRAM INSTALLATION AND PANEL ELEVATION AND DETAILS INSTALLATION AND PANEL DETAILS APPENDIX-A Bu l~ T // r.E. __ CARLSBAD OPERATIONS BUILDING RFVfF\JFD BY, JNSf-'lC I LR UA l I S~EET I 1C ITY OF C A.RLS BAD SI l[[TS ~ I ENGINFFRING [JFPARTMFNT ; 2 OF 7 l---t----t-----------f----l---f--~---1 t---t-----+-----------r-------l---+-----1 IMPROVEMENT PLANS FOR: SCADA INTEGRATION . -----------r--~'---+-----+---1 i ESS1 nrll {. .ct.® VICINITY AND LOCATION MAPS AND SHEET INDEX - -.. Ar':'RO_VfD _ /..2(_ WIL. LIAM E PLU'AM[R . CS718 f---+----+-----------r------+-----+-' --1 ~!:.if-i-., ~ -~ .. ,11:.~~--'4-(,-t2£ ~~e----+----1 f-'l 281 /6 EXr: 3-31-06 DErUTY CITY E~GINEER D~.T[ p. 091301 BLACK & VEATCH CO r p Or 8 ti On l--c-)A=TE,--+-,IN=,c=1AL-+--------------f-f-D=AT=[=i=-IN-_1"i,_L-+-. _DA_n:_· ~· IN_IT_IAL_, ~~~oBiv·_K_B.V-=! PROJECT NO. DRAWING NO. l , Los Angeles, California [NGIN[rn or WORK ~E:\/ISION DESCRIPTION CITY APPROVAL RVWD BY: AK , 36 7 :<3 4,31 7 ' ~ ~-l'___ ________ _J ___ _..L __________ _lo:'..'.'.Tl.::::lrn::.._:A::_:PP::.:_:RO-:.:.:_VA::.:_L L.....:....:...:..:...::__..:::..1..'.:::.::::::::::::'.::=====--===========:::'..'.:::=====::'.J GENERAL INSTRUMENT SYMBOLS FIELD MOUNTED INSTRUMENT INSTRUMENT MOUNTED ON FACE OF PANEL INSTRUMENT MOUNTED BEHIND OR INSIDE OF PANEL INSTRUMENT MOUNTED ON FACE OF LOCAL PANEL INSTRUMENT MOUNTED BEHIND OR INSIDE OF LOCAL PANEL SINGLE INSTRUMENT HOUSING CONTAINING lVv'O (OR MORE) INSTRUMENTATION FUNCTIONS CONTROL INTERLOCK FUNCTION, SEE SCHEMATICS AND SYSTEM SPECIFICATIONS FOR SPECIFIC FUNCTION TAG NUMBERS AND ADDITIONAL DESIGNATIONS / FIRST LETTER //~ .. /--SUCCEEDING LETTERS r TRC-' \~-11-----NUMBER AFTER DASH (-1, -2, ETC) DENOTES 1 -MULTIPLE DEVICES USED IN IDENTICAL \ DUPLICATE SYSTEMS. \ A LETTER AFTER THE LOOP NUMBER (31A, 31B, ETC) \ IS USED TO DISTINGUISH MULTIPLE SIMILAR DEVICES \ IN THE SAME INSTRUMENT LOOP. I ~---LOOP DESIGNATION NUMBER --p-a ---SEE INSTRUMENT ( ', FUNCTIONAL DESIGNATIONS \ 1 AND ABBREVIATIONS. "-...._ __ / 2" ·-~-PANEL REFERENCE NUMBER AS FOLLOWS: CUP= CHEMICAL UNLOADING PANEL ------ VCP1 = FILTER VALVE CONTROL PANEL (FILTERS 1 & 2) VCP2 = FILTER VALVE CONTROL PANEL (FILTERS 3 & 4) F = FILTER PLC (PLC F) ENCLOSURE T3 = TO\I\ER/111/ELL NO. 3 PLC (PLC T3) ENCLOSURE TAG NUMBERS MEANINGS OF IDENTIFICATION LETTERS --r·--------------... ===---------- l:t: FIRST LETTER w r-------~------- ~ MEASURED OR INITIATING MODIFIER VARIABLE !---+--------+------------. READOUT OR PASSIVE FUNCTION A ANALYSIS ALARM SUCCEEDING LETTERS OUTPUT FUNCTION r----t----------r---------1 c-------+------ BURNER. USER'S CHOICE USER'S CHOICE B COMBUSTION MODIFIER USER'S CHOICE f-------------+---------+----------j C CONDUCTIVITY (ELECTRICAL) r--t---~-------,--------., D DENSITY (MASS) OR SPECIFIC GRAVITY DIFFERENTIAL CONTROL PRIMARY ELEMENT E VOLT AGE (EMF) --+----- F FLOW RATE RATIO (FRACTION) +-----------jr------------ G USER'S CHOICE f----+------------t------GLASS H HAND (MANUALLY HIGH INITIATED) CURRENT (ELECTRICAL) f----+--~------ f---------+---------+---·------------j INDICATE ----------+ --------r- J ~ K L M POWER SCAN ---·----------------r--------------- TIME OR TIME-TIME RATE CONTROL STATION SCHEDULE OF CHANGE -------,-------- LEVEL f-_L_IG~T_(PILOT) --+-------- MOISTURE OR HUMIDITY MOMENTARY f----1---------+----------- N 0 USER'S CHOICE ----- USER'S CHOICE USER'S CHOICE USER'S CHOICE -- ORIFICE .. -~-----, LOW MIDDLE OR INTER- MEDIATE USER'S CHOICE (RESTRICTION) ----------1-----------p PRESSURE OR POINT {TEST Q VACUUM CONNECTION) ----i--------~-----·--.. ·----1------------j QUANTITY INTEGRATE OR INTEGRATE OR ' TOTALIZE TOTALIZE R RADIATION f-------~ - RECORD OR PRINT f----+---···--· --~------------,------------------ s T u V SPEED OR FREQUENCY TEMPERATURE MUL T!VARIABLE VIBRATION W I WEIGHT OR FORCE SAFETY --------- +--------+----------- SVVITCH i------------------------ TRANSMIT MUL TIFUNCT10N MULTIFUNCTION VALVE, DAMPER, OR LOUVER --------+-- WELL MULTIFUNCTION ·--------- X UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED y z EVENT, STATE, OR PRESENCE POSITION, DIMENSION -- -----------~--- ------j------- RELAY OR COMPUTE DRIVE, ACTUATOR OR UNCLASSIFIED FINAL CONTROL ELEMENT DIGITAL SYSTEMS INTERFACE SYMBOLS NOTE: REFER TO DETAILED SYSTEM SPECIFICATIONS FOR FUNCTIONAL DESCRIPTION. ALSO SEE 1/0 SCHEDULES FOR COMPLETE INPUT AND OUTPUT LISTINGS. DIGITAL SYSTEM 1/0 INTERFACE DIRECTION OF ARROW DENOTES WHETHER INPUT OR OUTPUT. A FILLED ARROW DENOTES ANALOG 1/0; AN UNFILLED DENOTES A DISCRETE 1/0. DEPENDING ON THE APPLICATION. A SINGLE ARROW OF A PARTICULAR 1/0 TYPE MAY SIGNIFY ONE OR MULTIPLE SIMILAR 1/0 POINTS. CONSULT THE PLC INPUT/OUTPUT SCHEDULE TO DETERMINE EXACT 110 POINT QUANTITIES. PROGRAMMABLE LOGIC CONTROLLER SYSTEM FUNCTION BLOCK. "CB" NUMBER REFERS TO SOFTWARE CONTROL BLOCK DESCRIPTION IN THE SPECIFICATIONS. GENERAL NOTES 1. IN GENERAL, THE P &ID SYMBOLS AND DEVICE IDENTIFICATIONS ARE BASED ON INSTRUMENT SOCIETY OF AMERICA, STANDARD PRACTICE ISA-S5.1 (1988). SOME MODIFICATIONS, ADDITIONS, ANO ALTERATIONS HAVE BEEN MADE AS NEEDED TO ACCOMMODATE THE PROJECT REQUIREMENTS 2. ADDITIONAL CONTROL AND INTERLOCK REQUIREMENTS VVHICH CAN BE MORE CLEARLY ILLUSTRATED ON SCHEMATIC DRAWNGS HAVE BEEN OMITTED FROM THE P & ID DRAV\llNGS. SOME PROCESS ITEMS, SUCH AS EQUIPMENT ISOLATION VALVES, BYPASS LINES, ETC. VVHtCH ARE NOT CRITICAL FOR AN UNDERSTANDING OF THE INSTRUMENTATION FUNCTIONS HAVE ALSO BEEN OMITTED. :3. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND ABBREVIATIONS MAY NOT BE UTILIZED ON THIS SPECIFIC PROJECT. 4. PIPING AND EQUIPMENT LEGEND APPLIES TOP & ID SHEETS ONLY ANO MAY DIFFER FROM LEGENDS FOR OTHER SHEETS FUNCTION DESIGNATIONS AND ABBREVIATIONS K -K F(X) > < X I COND DO F LEL MCC □2 INSTRUMENT DESIGNATIONS GAIN OR ATTENUATE (INPUT:OUTPUT) GAIN AND REVERSE ADD OR SUM (ADD AND SUBTRACT) SUBTRACT (DIFFERENCE) EXTRACT SQUARE ROOT DIVIDE CHARACTERIZE SIGNAL HIGH-SELECT LOW-SELECT MULTIPLY INTEGRATE (TIME INTEGRAL) METHANE CHLORINE RESIDUAL CARBON DIOXIDE CONDUCTIVITY DISSOLVED OXYGEN FLUORIDE LO\I\ER EXPLOSIVE LIMIT MOTOR CONTROL CENTER OXYGEN (PURITY) pH CELL TURB TURBIDITY PIPE MATERIAL ABBREVIATIONS A-20 ALLOY 20 CPVC CHLORINATED POLYVINYL CHLORIDE CS CARBON STEEL PVC POLYVINYL CHLORIDE OTHER ABBREVIATIONS CSU CHANNEL SERVICE UNIT DSU DATA SERVICE UNIT HAND SWITCH DESIGNATIONS HOA LR oc 00 LOR OOA OCR OOR OSCA HAND-OFF-AUTO LOCAL REMOTE OPEN-CLOSE ON-OFF LOCAL-OFF-REMOTE ON-OFF-AUTO OPEN-CLOSE-REMOTE ON-OFF-REMOTE OPEN-STOP-CLOSE-AUTO TRANSDUCER & CONVERTER DESIGNATION E VOLTAGE FSK FREQUENCY SHIFT KEYING H HYDRAULIC I CURRENT p PNEUMATIC PD PULSE DURATION PF PULSE FREQUENCY R RESISTANCE (ELECTRICAL) EXAMPLE: 1/P = CURRENT TO PNEUMATIC TRANSDUCER POWER SUPPLY ABBREVIATIONS AS AIR SUPPLY ES ELECTRIC SUPPLY GS GAS SUPPLY HS HYDRAULIC SUPPLY NS NITROGEN SUPPLY SS STEAM SUPPLY WS WATER SUPPLY AS '>--POWER SUPPLY SOURCE LABEL. USED ONLY WHERE NECESSARY TO HELP CLARIFY AN INSTRUMENT OR SYSTEM FUNCTION. LINE SYMBOLS PROCESS DEVICE SYMBOLS UTP UNTWISTED PAIR VALVE AND GATE ACTUATOR SYMBOLS ' - ---------' I - - -------- - - I ' --<:~> c:~>- -0--0-··- MAJOR PROCESS PIPING OR FLOW CHANNEL SECONDARY PROCESS PIPING MISCELLANEOUS PIPING SHADED OR LIGHT LINE WEIGHT DENOTES EXISTING OR FUTURE PIPING AND EQUIPMENT ELECTRIC SIGNAL HYDRAULIC SIGNAL PNEUMATIC SIGNAL ELECTRICAL DIRECTION ARROW SIGNAL CONNECTION POINT SIGNAL LINE GOING TO ANOTHER SHEET SIGNAL LINE FROM ANOTHER SHEET (MATCH LETTERS) FLOW ARROW FOR PROCESS PIPING PROCESS LINE GOIING TO ANOTHER SHEET MATCH SHEET NO. IDENTIFIER MATCH LINE NO. PROCESS LINE COMING FROM ANOTHER SHEET PROCESS LINES CROSSING (NOT CONNECTED) INTERNAL SYSTEM SIGNAL LINK (SOFTWARE OR DATA LINK) R I _ ____,, 'e------ 1 I {-~-· -· ~-... __ __; ---rn- -----fTTl- DIAPHRAGM SEAL ANNULAR TYPE DIAPHRAGM SEAL PURGE OR FLUSHING DEVICE POSITIVE DISPLACEMENT TYPE FLOWMETER PRIMARY FLOW ELEMENT: ORIFICE PLATE PRIMARY FLOW ELEMENT: VENTURI TUBE PRIMARY FLOW ELEMENT: FLUME PRIMARY FLOW ELEMENT: \M:IR PRIMARY FLOW ELEMENT: TURBINE OR PROPELLER-TYPE PRIMARY FLOW ELEMENT: PITOT TUBE PRIMARY FLOW ELEMENT: ELECTROMAGNETIC OR TRANSIT-TIME ULTRASONIC DOPPLER TYPE ULTRASONIC FLOW SENSOR PRIMARY ELEMENT: ROTAMETER DRAIN THERMAL DISPERSION TYPE FLOW ELEMENT N sz· 8 f - ------------ FLOW CONTROL OR ISOLATION GATE VALVE: GLOBE, GATE, OR OTHER IN-LINE TYPE NOT OTHERWISE IDENTIFIED VALVE: EXISTING OR FUTURE VALVE: THREE WAY VALVE: FOUR WAY VALVE: BUTTERFLY, DAMPER OR LOUVER VALVE: ROTARY BALL TYPE VALVE:CHECK VALVE: PLUG TYPE VALVE: DIAPHRAGM VALVE: PRESSURE RELIEF VALVE: VACUUM BREAKER PULSATION DAMPENER STRAINER CALIBRATION COLUMN vs p:(AJ3 M PUMP VS DENOTES: VARIABLE SPEED PUMP (CHOPPER) SCREW (LIFT) PUMP PROGRESSING CAVITY PUMP MIXER ... PROPORTIONING OR METERING PUMP MOTOR RING DIFFUSER WYYYYYYYYYYYYYYYYYYYYYSI TRUCK WEIGH SCALE IC HOSE CONNECTION f p 41 ~ cp ~ y y C? NO SYMBOL DIAPHRAGM DIAPHRAGM WITH POSITIONER PRESSURE-REDUCING VALVE, SELF-CONTAINED PRESSURE-SUSTAINING VALVE, SELF-CONTAINED AIR CYLINDER SOLENOID AIR-OIL CYLINDER ELECTRIC MOTOR HYDRAULIC CYLINDER MANUALLY (HAND) OPERA TED THE FOLLOWING ADDITIONAL DESIGNATIONS MAY BE UTILIZED ADJACENT TO SOME VALVE OR GATE SYMBOLS NC NORMALLY CLOSED FC FAILS CLOSED FO FAILS OPEN FIP FAILS IN LAST POSITION --- APPENDIX-A "AS BUILT" P.E. ___ _ EXP. ____ _ DATE REVIEWED BY: INSPECTOR DATE fsHml CITY OF CARLSBAD l----+----+-------------------+----+----+---1----1 L_i:1___j ENGINEERING DEPARTMENT l----+----+-------------------+----+---+---1----1 SHEETS 3 OF7 11lf'ROVEMENT PI.IIN:1 FOR SCADA INTEGRATION INSTRUMENTATION & CONTROL DRAWING LEGEND AND ABBREVIATIONS ~,~, D ~,"l{:'K"tf &% i -.... <> ~;(, · 1\ APPROVED (! '""' 1 1AM E. PLUMMER iiocS7187 I'll -·~--+:;.~;;;e;..h"""_.'l"l.. ____ {,-'-•QS * /'P-09130/06 * BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE "' !CJ,~ A> C I OWN BY: I PROJECT NO. I DRAWING NO. ~':"~""""m,.L;e;SfO""» '<ft;~ o r p o r a I o n DATE 1N1T1AL DATE INITIAL DATE 1N1T1AL cHK □ BY: OF c,c1G C. [1.l oS L ____ L_o_s_A_n_g_e_1e_._· c_a_,;_,o_,_"i_a ____ _LE_NG_1_NE_E_•_o_•_w_o_•<-1.. ____ R_E_v_1_s_1o_N_D_E_s_c_R_1P_T_1_o_N ____ _J~O~T~H-E-:::_-•::.-A::P~P~R-O'::..-V:.:A;L~~~~c-1_T_Y_-A_-'-P_P~R-O---V--A~L:L.:: ~R=V=W=D==B=Y"'-=:'-="'::=:::=:::=:::'::':::...::====3=6=7=5=3===::'.:~=4=3=1=-7=:::::'...J • • • • • PLC-PS-RW RECYCLED WATER PUMP STATION AT CARLSBAD WRF JOINT USE FACILITY (NOTE 4) • • • • • PLC-PS·T TWIN D RECYCLED WATER PUMP STATION, RWPRV STATION & PWPRV STATION • • ,,0,,UBBBSBBB§BEt aouu<>□□□□aooou □ c ! I I I I I I I I ,...C'!...._ - - - - -_.., LL -:::i r_:gggg,:g~i888~ l"I ciOc,c,c,oc,c,co""""'"'] I r-!!." ~" ,::_,-, •.:.,:• --~, c.:;_, "~ ~ :;:J I I I I I I I I I I I I I I I I~ ·+-+-t-t-+-+-+ l•I --r---T '-[!,--- - - - --,, r PLC-RES-I/ MAHR RESERVOIR (FLOW ONLY) (NOTE 3) ( DDDD """') OMNI-DIRECTIONAL ANTENNA ( SPREAD-SPECTRUM "MASTER" RADIO ~=i DIRECTIONAL YAGI ANTENNA HOT STANDBY REDUNDANT CONTROLS SYSTEM 110 SERVERS • ! I I KVM SWITCH C=::JsPREAD•SPECTRl/!t "REI/OTE" RADIO • • • • PLC-RES-C RESERVOIR C TO DIAL-UP TELEPHONE r-----l►SERVICE FOR REI/OTE ACCESS AND ALARM PAGING • • WORKSTATION COMPUTER (TYP.) RUNNING MONOERWARE INTOUCH • • • PLC-PS-B • ic •••• =)r--t ________ il _/ • • J-~R~I~:~ 3~:1~ ,,, ~~" "" LlC• □□ D □ □'1110 l'] rJ(j • BRESSI RECYCLED WATER PUMP STATION • • • • PLC-PS-C CALAVERA RECYCLED WATER PUMP STATION FARADAY PRESSURE REDUCING STATION (NOTE 1) RTU-PRV-C LA COSTA PRESSURE REDUCING STATION (NOTE 1) ' 1( IHH "=") I I ASED-LINE CIRCUIT BRIDGE (BY TELEPHONE SERVICE PROVIDER) 1( •••• =)1 MODEM • • PLC·M MASTER PLC • • • CONTROLS SYSlEM DATABASE SERVER #1 (\ I/ ·••~ CATEGORY 5e DR 6 UT/> CABLE (TYP.) CONTROLS SYSTEM DATABASE SERVER #2 0 0 LEASED-L.INE CIRCUIT BRIDGE 1 • u0u ~ ~ ~ [i ~ ~ 0 " " -§ ~ • (BY TELEPHONE SERVICE /----------------'---(,,,, =)f---""""""""""'"'" "" I PROVIDER) MODEM AVENIDA ENCINAS PRESSURE REDUCING STATION (NOTE 1) ANALOG VG LEASED-LINE TELEPHONE SERVICE (TYPICAL) ' ~-------------------------- ETHERNET O ::: IJl,)lJL)LJIJLJL)I . . SWITCH I PLC-OPT NOTE 2 '----------------, E (]iiiiiD I I LASER REPORTS PRINTER RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING NOTES: 1: EACH PRV SITE IS PROVIDED WITH OPTO 22 SNAP IO AND MODEM PRE INSTALLED. CONTRACTOR IS TO COORDINATE WITH OWNER AND TELCO LEASED LINE PROVIDER TO COMPLETE PROGRAMMING OF RTUs AND INSTALLATION. OF MODEMS. MODEMS SHALL BE BLACKBOX MODEM 3600. 2: OPTO 22 SNAP-LCM4 LOCAL CONTROLLER TO BE INSTALLED WITH M4SENET-100 ETHERNET CARD AND SNAP-PS5 POWER SUPPLY TO MATCH EXISTING STANDARD. 3: MAHR PLC BY OTHERS. CONTRACTOR TO PROVIDE MODEM AND SCADA GRAPHICS. 4: PLC-PS-RW SUPPLIED AND PROGRAMMED BY OTHERS. APPENDIX-A "AS BUil T" P.E. __ _ EXP. ___ _ DATE REVIEWED BY: INSPECTOR DATE l---+---+-----------------+--~l----=c====c===J-:==::::::::';::::===========::::;-;:=:::::::::::::-1 ISHEE'r] CITY OF CARLSBAD SHEETS l-----+----,1-------------------+---+---+---+--_., ~ ENGINEERING DEPARTMENT 4 OF 7 l----!--+-----------------!l----+--+----+-----1 JMPROVEMENT PLANS !'OR: SCADA INTEGRATION INSTRUMENTATION & CONTROL DRAWING D 1-----+---if---------------if---+--+----+----l SCADA SYSTEM FUNCTIONAL BLOCK DIAGRAM -..... APPROV~O • ~ E. PLUMMER l-----+----,l-------------------+---+---l-----1------ll.,P."4~~~~~~~~, ..... ~es...~~'./:::-.;2'!!W!aM~•-·~~,:i..---G-~-d5 BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE C I I OWN BY: PROJECT NO. DRAWING NO. l O r p O r a O n DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: '). .,s L-----L-os_A_n_g_e_1e_•_• c_a_li_fo_rn_ia ____ _._E-NG-I-NE_E_R_oF_w_o_R_K..1... ____ R_E_V_IS_I_O_N_D_E_S_C_R_IP_T_I_O_N ____ ..J..o_T_H_ER_A_P_P_Ro_v_A_L_.__c_rr_v_A_PP_R_ov_A_L..J.._R_VWD __ B_Y_: ________ 3_6_7_5_3 _____ 4_3_1_-_7_.....J i .. ' ' ' lTEII A 8 = ~-- i • 2"X2' WIREWAY ' ~ IT] \ \\ PUMP STATION PLC/TELEMETRY _PANEL LAYOUT !IIITERIAL LIST DESCIIIPTION NEMA Type 4X, ata.1nlua ateel enclosure JNasuring :JS•x30"x12", thrH-point latch1ng, padlockable handl■, and backp■nel. QFI dual utilitv outlet. w1th C Feed through terldn■1 blocks1 aepar■t1on barrtera, and' Ju.per b■rs. D Fused termin■l block wtth blown fuse 1nd1c■tor (size ■3 needed}. E 120Vac DIN rail ""unted relavtter11in■l block -SPST. F 24Vdc DIN rail IIOUfrtltd relay/t.,.lld.nal block· SPST. 8 120V■c DIN r■tl aounted rel ■vttermtn■l block -DPDT. H ,,,.ch■ntc■l door awttr.h f Intrusion). l Fluorescent ltaht wJth Nnu■l switch. J Surg■ protection deyic•. K 24Vdc. 100W power aunnJ 11. L 750VA UPS. #OTES; 1. NOT ALL DEVICES AMY 8E SHOWN 2. ALL DIMENSIONS ARE FOR REFERENCE ONLY 3. COMPONENT PLACEMENT FOR REFERENCE ONLY 4. ALL INTERNAL INSTRUMENT AND COIIPONENT DEVICE 'lfIRINO SHALL 8E AT LEAST 16 Allll. ANALOG CIRCUITS SHALL BE 16 Atm TWISTED AND SHIELDED PAIRS RA.TED FOR AT LEAST 300 VOLTS. ANALOG CIRCUITS SHALL BE SEPARATED FllOII AC POWER CIRCUITS. 5. PANEL FABRICATOR SHALL WIRE THE IIIELL PLC PANEL AS SHOWN ON SCHEMATICS. IN ADDITION, THE PANEL FABRICATOR SHALL 'lfIRE ALL PLC I/0 SIGNALS TO THE TERMINAL BLOCKS. 6. THIS DRAWING DETAILS THE INSTALLATION AND CONSTRUCTION OF A TYPICAL PUIIP STATION PLC PANEL. FOUR OF THESE PUMP STATION Pf.C PANELS WILL BE REQUIRED FOR THE TWIN D, BRESSI, CAlAVERA ANO RECYCLED WATER PUMP STATIONS. 7. CONSTRUCTION OF THESE PANELS SHALL COIIPLY WITH 2003 NATIONAL ELECTRICAL CODE. 8. THE LEASED LINE PHONE EQUIPMENT SHALL 8E SUPPLIED AND INSTALLED BY SYSTEM SUPPLIER. 9. RElA Y TERMINAL BLOCKS SHOWN FOR REFERENCE ONLY. ACTUAL RE'LAY REQUIREMENTS NEED TO BE FIELD DETERMINED BASED ON FIELD WIRING IN EACH INDIVIDUAL Pf/MP STATION TERMINATION CABINET INSTALLED BY OTHERS. 10. TELEPHONE SERVICE CABLE AND CONDUIT TO BE PROVIDED AS SPECIFIED IN SECTION 13500. 11. COORDINATE CONDUIT SIZE AND NUAf8ER OF CONDUCTORS WITH CONTRACTOR. 12. DRAWING SHOWN FOR REFERENCE ONLY. CONSULT EWA EFFLUENT EQUALIZATION AND CARLSBAD IIRF JOINT USE FACILITIES ELECTRICAL DRAWINGS FOR FURTHER DETAIL. DRAWINGS AVAILABLE FRO/I THE 01111/ER. PLC/TELEMETRY PANEL "' "' -" 0 -,, "' --" [~ ~i ., .. -" " "' ---" TYPICAL PUMPING STATION PLC/TELEMETRY PANEL ONE-LINE (<CfESSI~ . "t.~ ' . ' " ST AJNLESS STEEL ENGRAVED "RTU- NAMEPLATE CWPBE~ 72" (M AX) ,-NEMA 12 ENCLOSURE HOFFMAN OR EQUAL I'\ - 11 De I \ 36" 'MAX1 \ b i • . . 1 1 ' I ' ' i ' i ' ' 1r I( 24• DEEP (MAX) ~---INCOMING POWER FUSE BLOCK • . • ETHERNET PATCH PANEL ETHERNET NETI/VORK SWITCH MODEM JI MODEM JI PLC RACK WITH PROCESSOR, POWER SUPPLY, ETHERNET COMMUN/CA TJONS CARD AND I l/0 CARDS AS REQUIRED ~I/ 60" (APPROX) SEPA OPTO 22 SNAP-LCM4 CONTROLLER WITH POWER SUPPLY, EHTERNET COMMUNICATIONS CARD AS REQUIRED WAY WTTH DfVIDER TO RATE POWER AND ~Lo\lJRE NET WORK CABLING EXTERIOR VIEW INTERIOR VIEW RECYCLED WATER CONTROL CENTER AT CARLSBAD OPERATIONS BUILDING COMMUNICATION ENCLOSURE NO SCALE -------------------------~---~---~-------,~------~ J EXISING RIO CABINET IRRIGATION OONTROLLER TERMINAL JUNCTION BOX C-------, 0 ' I ' ' ' ' ' ' ' ' ' ' ' ' ' .. !:;; I ------------ RECYCLED WATER PUMP STATION AT CARLSBAD WRF JOINT USE FACILITY ELECTRICAL ROOM NO SCALE (NOTE 12) APPENDIX-A "AS BUil T" PE EXP, DATE REVIEWED BY: INSPECTOR DATE ~ CITY OF CARLSBAD SHEETS 50F 7 -3 ENGINEERING DEPARTMENT IMPHOV[MJ,:NT PLANS FOH SCADA INTEGRATION INSTRUMENTATION & CONTROL DRAWING NSTALLATION AND PANEL ELEVATION DETAIL! APPROVED I':, """'AME, PLUMMER .i, .:-_ ~ G-,-M l No. CS7187 * E,p, 09130/06 * BLACK & VEATCH PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE <I',> "'~ ## "< \ • OWNBY: I I PROJECT NO. DRAWING NO, Corporation DATE INITIAL c,~~ lSi ~' \\, 0 ~ DATE INITIAL DATE INITIAL CHKD BY: Los Angeles, California REVISION DESCRIPTION 36753 431-7 OF cAc'1 \:, ENGINEER OF VVORK OTHER APPROVAL CITY APPROVAL RVWDBY: C :e c,, (i) ~A ...... <,.) ..... I ....... 2' -0" END CAPS~ n----. 1· NEMA 4X 315 STAINLESS STEEL --' 12" MIN NO SCALE ~ C ~ ~ ' "' ., ~ ~ ~ ,. " ~ <o ' ' I PLC I I RADID 12V DC LEVEL CHARGE TRANSMITTER CONTROLLER I FUSES I BATTERY BATTERY (16" DEEP) v \_ TO SENSOR JI "' TO ANTENNA ___/ \_ TO SOLAR PANELS I UNISTRUT 316 STAINLESS STEEL CHANNEL WITH CLOSURE STRIPS (TYPICAL) ✓3/4'' GROUT Al..L AROUND -(TYPICAL) ' == NOTE 2 4·6/8" EXPANSION _ _/ ANCHORS PER BASE PLC PANEL MOUNTING DETAIL TYPICAL FOR: RESERVOIR C -3!4"C, TSP CABLE PER r UPNISTRUT 316 STAINLESS STEEL OST BASE (TYPICAL) PROVIDE ELECTRICAL\ MFR. REQUIREMENTS CONDUITJUNCTION BOX 1 (WOTE 10) FOR LEVEL SENSOR. r,::;=n::::=, TD PLC 1--~----'_J~ •1-_______ _;,---:.,_r_~ • ~ ... 31'-0" UNIT "C" j ~ RESERVOIR SUBMERSIBLE r--LEVEL SENSOR I WITH WEIGHTS I I I </ RESERVOIR C LEVEL INSTRUMENT INSTALLATION DETAIL NOTES: 15' -0" 1. THE CENTERLINE OF ANTENNA ELEVATION SHALL BE 35' ABOVE GRADE. PLC 2. PANEL DIMMENSIONS ARE A MINIMUM, THE SYSTEM SUPPLIER SHALL PROVIDE PANElS SIZED AS REQUIRED FOR ALL EQUIPMENT SPECIFIED. 3. ATTACH CABLE EVERY 42" WITH STAINLESS STEEL HARDWARE. LEGS SHALL NOT BE WELDED OR DRILLED. PORCELAIN INSULATORS TO SEPARATE GROUND FROM LEG AND STAINLESS STEEL HARDWARE. 4. WELD BASE AND SUPPORT AS REQUIRED FOR ANTENNA LOCATION. 5. CADWELD JOINT AND #2/0 GROUND CONDUCTOR INSTALLED PER ANTENNA AND/OR TOWER MANUFACTURER RECOMMENDATIONS. CONTRACTOR SHALL ALSO GROUND RADIO ENCLOSURE 6. MINIMUM BEND RADII SHALL BE STRICTLY OBSERVED FOR ANTENNA FEEDLINES. 7. ALL PENETRATIONS SHALL BE SEALED TO BE WATER TIGHT 8. THE UNIT "C" RESERVOIR LEVEL TELEMETRY STATION IS SOLAR POWERED AND THEREFORE IS NOT PROVIDED WITH A RELAY WHICH INDICATEDS THE LOSS OF UTILITY POWER. 9. INSTALL ANTENNA .MAST ON EXISTING STRUCTURE. 10.INSTAlL CONDUIT FROM THE PLC CABINET TO THE RESERVOIR UNDERGROUND. EXPOSED CONDUIT FROM THE BOTTOM OF THE RESERVOIR TO THE LEVEL PROBE AND THE ANTENNA SHALL BE INSTALLED ALONG THE SAFETY LADDER IN A NEAT MANNER. GRADE-~ SHIELo-- 0 0 ___ HELIAJ< CABLE ~-GROUND STRAP ANDREW TYPE 204989 WATERPROOF GROUND STRAP ASSEMBLY AFTER INSTALLATION ------#2/0 GROUND TYPICAL HELIAX GROUNDING DETAIL NO SCALE ROHN TYPE 250 TOWER - NOTE 9 NOTE 5 / _ __/ NOTE 3 ----------5 I B " X 8 ' GROUND ROD WIRE JOINT SHALL BE CADWELD I / \/ 1\ I I I' I I 1/ / I \ / NOTE 4 --WALKWAY I DATA CABLE CARLSBAD OPERATIONS BUILDING MOUNTING DETAIL NO SCALE ROOF a@ 2" x1 /8" BAR STRAP 3" OR SMALLER PIPE 1 4" CLEAR 2"x1/8" STRAP-- 1/2" GALV BOLT AND EXPANSION ANCHOR D D VERTICAL PIPE SUPPORT NO SCALE MAST HEIGHT TO BE DETERMINED BY CONTRACTOR. SEE SPECIFICATIONS FOR ANTENNA HEIGHTS PER LOCATION. DIRECTIONAL YAGI ANTENNA (ORIENTATION NOT ANTENNA MAST (MOUNTED PLUMB) NECESSARILY AS SHOWN)-------+-+-+-+-+-< GROUND WIRE CADWELD JOINT SUPPORT CABLE PER MANUFACTURER'S RECOMMENDATION, OR EVERY 3' MINIMUM.---+-' MAINTAIN AT LEAST MANUFACTURER'S RECOMMENDED MINIMUM BEND RADIUS #2 COPPER HANDRAIL VERTICAL------.. SECTION SEAL END OF CONDUIT WITH WATERPROOF SEALANT AND CAP MAST EXTENSION TO PROVIDE 60" LIGHTNING PROTECTION CONE HELIX CABLE ANTENNA FEEDLINE GRADE .______, 5/8" X 8' GROUND ROD WIRE JOINT SHALL BE CADWELD RESERVOIR C ANTENNA MOUNTING SECTION NO SCALE NOTE: D=DISTANCE FROM WALL AS REQUIRED. RESERVOIR C TANK ROOF APPENDIX-A "AS BUil T" P.E. ___ EXP. ____ _ DATE REVIEWED BY: INSPECTOR DATE ~CTTY OF CARLSBAD >----+----1--------------------+----t---+---<f---.1 ~ ENGINEERING DEPARTMENT 1----+---+-------------------+----t----t----tf---l SHEETS 60F7 IMPROVEMENT PLANS FOR- SCADA INTEGRATION INSTRUMENTATION & CONTROL DRAWING INSTALLATION AND PANEL DETAILS BLACK&VEATCH ~-~---~-~-os PE 28176 EXP: 3-31-06 DEPUTY CITY ENGINEER DATE OWNBY: PROJECT NO. DRAWING NO. 431-7 Corporation Los Angeles, California DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKDBY: RVWDBY: 36753 ----------------------·--------------------- I I l OFFICE -- OFFICE NEW SCADA WORKSTATION AND PRINTER ~ RECEPTION CENTER / r a OFFICE -':-EXISTING LIGHTING PANEL ( NOTE 1) - 0 I I • 24" • I /- / 1,,/ ,,-- I I □ /- I I / I I ) - ~ ~ ~ E"JE"l ~~ ~E::5 E::::l E5 E"JE"l == == == ES§s §3§5 ETHERNET LAN SWITCH ADJUSTABLE EQUIPMENT BRACKET MONITOR SHELF WITH KEYBOARD DATABASE SERVER #1 DATABASE SERVER #2 1"C-2#12 r-J #12GND MULTIPURPOSE RACK CHATSWORTH 24 "X7' STANDARD RACK OR HERGO STANDARD 24" RELAY RACK (OPEN DESIGN) ' . • ', ' . •~ .,,,-M-' ~ROUTE CABLING THROUGH EXISTING I -------;;;::;>/ COVERED WIRE TRENCH ~ < ) r // ----++~NEW SERVER LOCATION ":,,_ ,/, {;J ,1/~~/,,/,/:· .// ----------,-_1 INSTALL POWER CABLING TO UPS AND ,, ,/ (ij. Ov:< (,,., ,/ i EXISTING BUILDING LIGHTING PANEL ,,, ' ,(] . \ ' \ ' '~,· \\ ·,.,,,.,~ INSTALL OMNI DIRECTIONAL ANTENNA ' \ ,__ PER MOUNTING DETAIL ON SHEET I-4 . d::, : , ....... J]~-----EXISTING ANTENNA 1 1 '\__ UNINTERRUPTIBLE POWER SUPPL y (UPS) FOR l NEW SERVERS AND COMMUNICATION ENCLOSURE -COMMUNICATION ENCLOSURE FOR MASTER PLC AND OPTO 22 SNAP-LCM4 CONTROLLER NOTES: APPENDIX-A 1 • CONTRACTOR SHALL COORDINATE WITH THE CITY TO TIE INTO A SPARE EXISTING 12OVAC CIRCUIT. /; AS BUlL I 11 PE_ EXP. DATE REVIEVED BY, TN~PF[T□R DATE ~ CITY C)F' CARLSBAD SHEETS - ---ENGINEERING DEPARTMENT 7 OF 7 5 IMPROVEMENT PLANS r'OH: SCADA INTEGRATION • CARLSBAD OPERATIONS BUILDING 19® ' -----.~PP ROVED -@ WILLIAM E. PLUMMER 6-~-06' &416; t: ,,,,., l< BLACK&VEATCH PF 281 ifi EXP . . 3-31-Clb UU'L IY CIIY E_NGINEER DATE -OWN BY KBV PROJE_CT NO. DRAWING NC. Corporation n,'I.TF INITIAi DATE INITIA.L l")ATF INITIAi CHKLJ ~Y: Los Angeles, California REVISION DESCR PTION I---- . -------36753 431-7 I:. \IIJINttJ>; 01-WOt-,;K Cl l Y APPROVAL RVWD BY AK OTHER APPROVAi C :e ..... G') ~A ...... w ....II I ""