HomeMy WebLinkAbout1877 ARTEMISIA CT; ; CBRA2020-0215; PermitBuilding Permit Finaled
{city of
Carlsbad
Residential Associated Permit
Print Date: 06/11/2021
Job Address: 1877 ARTEMISIA CT, CARLSBAD, CA 92011
Permit Type: BLDG-Associated Permit Residential Work Class:
Parcel#: 2150530145 Track#:
Valuation: $322,795.81 Lot#:
Occupancy Group:
#of Dwelling Units: 1
Project#:
Plan#:
Bedrooms: Construction Type:
Condo
CT140010
107
DEV14060
Bathrooms:
Occupant Load:
4
3.0 Orig. Plan Check #: PC2020-0009
Plan Check #: PC2020-0050
Code Edition:
Sprinkled:
POINSETTIA 61
Permit No: CBRA2020-0215
Status:
Applied:
Issued:
Finaled Close Out:
Inspector:
Final Inspection:
Closed -Finaled
12/01/2020
12/29/2020
PBurn
06/11/2021
Project Title:
Description: POINSETTIA 61 (TREVISO): PHASE 14 / LOT 107 / PLAN 2 / 2,011 LIVING/ 434 SF GARAGE/ 83 SF PATIO
Applicant: Property Owner:
LENNAR COMMUNITIES INC
ALAN CHIK
25 ENTERPRISE, # 400
ALISO VIEJO, CA 92656-2708
(949) 204-4628
LENNAR HOMES OF CALIFORNIA INC
15131 ALTON PKWY, # UNIT 365
IRVINE, CA 92618-2385
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
(949) 204-4628
COMMUNITY FACILITIES DISTRICT (CFD) FEE -RES
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PARK IN-LIEU FEES SF DETACHED & DUPLEX: SW
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SEWER BENEFIT AREA FEES -J
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SW PPP INSPECTION FEE TIER 1 -Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM
TRAFFIC IMPACT Residential Condo Outside CFD
Total Fees: $30,854.47 Total Payments To Date:
Building Division
$30,854.47
Contractor:
LENNAR HOMES OF CALIFORNIA INC
15131 ALTON PKWY, # UNIT 365
IRVINE, CA 92618-2385
(949) 204-4628
Balance Due:
AMOUNT
$1,417.65
$912.97
$3,617.04
$66.00
$175.00
$92.00
$5,728.00
$182.00
$11,297.85
$13.00
$2,112.00
$998.00
$41.96
$246.00
$55.00
$3,900.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
Permit Type: BLDG-Associated Permit Residenti, Application Date:
Work Class: Condo Issue Date:
Status: Closed -Finaled Expiration Date:
IVR Number:
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No.
Friday, June 11, 2021
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC
12/29/2020 Subdivision:
10/06/2021 Address: 1877 ARTEMISIA CT
30549 CARLSBAD, CA 92011
Inspection Primary Inspector Reinspection Inspection
Status
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
-----···' '' -·--·---
# ' ~ . .
_ PERMIT INSPECTION fflSTORY for (CBRA2020 .. 0215) .
Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC
Work Class: Condo Issue Date: 12/29/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 10/06/2021 Address: 1877 ARTEMISIA CT
IVR Number: 30549 CARLSBAD, CA 92011
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/21/2021 01/21/2021 BLDG-11 148815-2021 Passed Chris Renfro Complete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-12 Steel/Bond 148816-2021 Passed Chris Renfro Complete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/18/2021 02/18/2021 BLDG-14 150844-2021 Partial Pass Paul Burnette Reinspectlon Incomplete
Frame/Steel/BoltlngNle
!ding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/05/2021 03/05/2021 BLDG-15 Roof/ReRoof 152102-2021 Passed Tim Kersch Complete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/25/2021 03/25/2021 BLDG-13 Shear 153547-2021 Passed Paul Burnette Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/09/2021 04/09/2021 BLDG-82 Drywall, 154595-2021 Passed Paul Burnette Complete
Exterior Lath, Gas Test,
Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
05/07/2021 05/07/2021 BLDG-Electric Meter 156836-2021 Passed Paul Burnette Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/11/2021 06/11/2021 BLDG-Final Inspection 159491-2021 Passed Chris Renfro Complete
Friday, June 11, 2021 Page 2 of 3
Building Permit Inspection History Finaled
(city of
Carlsbad
Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC
Work Class: Condo Issue Date: 12/29/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 10/06/2021 Address: 1877 ARTEMISIA CT
IVR Number: 30549 CARLSBAD, CA 92011
Scheduled Actual Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Date Start Date
01/06/2021 01/06/2021 BLDG-21 147771-2021 Passed Tony Alvarado
Friday, June 11, 2021
Underground/Underflo
or Plumbing
Checklist Item
BLDG-Building Deficiency
COMMENTS
January 6, 2021: (virtual inspection).
1. Underground sewer waste and vent
lines, under water test-approved.
2. Underground floor plumbing lines, under
water test-approved.
3. Water plumbing lines, wrapped and
protected, under water test-approved.
4. Scope of all underground plumbing
piping and lines shaded correctly and
approved per engineers plans and detail
specifications
BLDG~22 Sewer/Water
Service
147774-2021 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
COMMENTS
January 6, 2021: (virtual inspection).
1. Underground sewer waste and vent
lines, under water test -approved.
2. Underground floor plumbing lines, under
water test-approved.
3. Water plumbing lines, wrapped and
protected, under water test-approved.
4. Scope of all underground plumbing
piping and lines shaded correctly and
approved per engineers plans and detail
specifications.
BLDG-23
Gas/Test/Repairs
147636-2021 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
COMMENTS
January 6, 2021: (virtual inspection).
1. Underground sewer waste and vent
lines. under water test -approved.
2. Underground floor plumbing lines, under
water test-approved.
3. Water plumbing tines, wrapped and
protected, under water test-approved.
4. Scope of all underground plumbing
piping and lines shaded correctly and
approved per engineers plans and detail
specifications.
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Page 1 of 3
,,
L
'
Southwest Inspection and Testing, Inc.
441 Commerclal Way, La Habra, Ca 90631
(562) 941-2990 • (714) 526-6441 • Fax (562) 1146-ooz&
REGISTERED INSPECTOR/AC! TECHNICIAN DAILY REPORT I SWIT Job No. r Dale; /. IQ,✓.,,.. I q J I ?' , ?, I
TYPE OF I J Reinforced Concrete U Welding 1,...1 DIA/Efloxy ' INSPECTION ~ Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED Reinforced Masonry D Asphalt n Other
Job Address , JU _ • -t"t...e. -Tract No. I Ph818 ~ol~ . 1.0-r -
Penn~-_ Job Name , 1 17,.,, "I,<~, --r11ued By
Type of Structure <.. r-J • (" _ Archltacr .. /~
Material Description (type, grade, souroe) Engineer (. ~ ,, /'I_,
~ --~ -\/4 0 _::,,. -•• / .. -Contractor 1 _ , -AJ,r-
Inspector's Name r<.. /\] ,, . Subcontractor /" ;:-T --
~ TESTS PERFORMED .
SAMPLE AIR CONC WATER TIME SEllll TRUCK# TlCKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS
INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS,
REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & !DENT. NO'S OF
TEST SAMPLES TAKEN: STRUCT. CONNECTIONS twELD MADE H.T. BOLTS TORQUED\ CHECKED ETC. -,---.,,__ ----~ ~ -·-· -LA..._,--. ,-~,) 0.-,.__~----·-F
--,--;., --VI,<" ,/ .'h ,,~ ~ \~ ..._,,__ -~ ( .:.,,,~ -----./ J.
,1 .,..x>-, . --ic, ~ o.r , -r~J.oa ,,,,.ero:.. ?f1 O'-{ "+,::. <:" ---, *,e-r ~V\ ,e__p..::., ~.,..., !#< I ,,,,.., I -A6,-·------. , 1 • ...,.s ,C_•_-,A..-.a -·•-~ J .!$/'7 ~ ... -. , V ( t' t<..,e-? 0~ e, _\
I ,--,,r--~ I ~"2. I ~c-,-, A I? _,r£•. -I .._, .A. ,,. ,"I". I -07 lo
V if:=to~ .~.oi~ • ., -If; r,::,, ,,
" 1--iA<.J ( ~ -'1141 I 8 '11 ., " *0~12 <J711 / A
i"' t=<"
. ,e-, rr, lf:.ec.1~ • •• ~
~ 11"-l A{ -/QO. 1 ., ~ 'fl: o?..l '-1
• 1 1:' IAJ , 2,-, " I * 0 '?'IS
CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE 0
I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE
ALL OF THE ABOVE R D WORK UNLESS OTHERW'8E NOTED. I HAVE TIMEIN TIMEOUT SAMPLES
FOUND THIS W LY WITH THE APPROVED PLANS, SPECIFICATION,
AND APPL E ION OF THE G G LAWS.
Approved By ____ ~--,-..,.-c--c-;--;--,------
Project Superintendent
Whtt• _ Office Copy • Canary-Accoun#ng Copy • Pink -tnspectol's Copy • Goldenrod -Jobsite Copy
0/~~
C . 'IE . -~s,£' tvl ngrneermg • 11rvey111g
Certified: SDVOSB • DVBE • SBE • CPUC
January 21, 2021
J.N. 14-1018-1
City of Carlsbad Building Department
Attn: City of Carlsbad -Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
RE: Poinsettia 61-Form Certifications for Units 102 through 107
CT 14-10, Map No. 16329
City of Carlsbad Building Department,
GOiay
Based upon topographic surveys performed by 0' Day Consultants on January 13, 2021
for Units I 02 through I 07, the foundation forms for land development have been
completed within standard tolerance (0.10 feet) in accordance with the approved plan,
(City of Carlsbad DWG. 507-2C)
O' Day Consultants Inc.
O'DAY CONSULTANTS, INC.
Very truly yours,
/2.cnr-O iJar
George O'Day /
Project Manager
2710 Coker Avenue West, Suite 100
Carlsbad, California 92010-6609
E-mail: oday@odayconsultants.com
Website: www.odayconsultants.com
Tel: 760.931.7700 Fax: 760.931.8680
G:\141018\Survey\FormCertS\ 141 BA-EXHB-FormCert_ 102-107. doc
GRCUPDELT.l\
9245 Activity Rd., Ste. 103
San Diego, CA 92126
Tel: (858) 536-1000
Project Name: Poinsettia 61 Development
Project No.: SD412B
Project Location: Poinsettia Lane, Carlsbad, CA
Client: Lennar Homes of California
Contractor: Hermanos Construction
Group Delta PM: Taylor Latimer, PE
TYPE OF WORK PERFORMED
Soils I Earthwork
EQUIPMENT USED BY CONTRACTOR(S)
Backhoe
DESCRIPTION OF WORK PERFORMED
Location of Work: Aisle "R" -Lot #s 102, 103, 104, 105, 106, & 107
Daily Field Report
Date: 1/13/21, Wed
Weather: Sunny
Start Time: 9:00 AM
Lunch Time: n/a
End Time: 12:00 PM
Total Hours: 2
Work Performed: On site as requested to conduct inspection of footing subgrades at the above mentioned locations.
Footing excavations were completed prior to arrival on site. Soils appeared to have been sufficiently moisture
conditioned. Footing subgrade soil was examined using a soils probe and was found to be generally firm and
unyielding.
Accepted By: Submitted By:
Signature: Signature:
Name: Rick Kuzyk Name: Jonathan Davis
Title: Site Superintendent Certification: ICC# 5236421
Representing (Company): Lennar Homes Group Delta Consultants, Inc.
Page 1 of2 DFR v 2018.03
CiRCUP DEL T.A
9245 Activity Rd., Ste. 103
San Diego, CA 92126
Tel: (858) 536-1000
DESCRIPTION (CONTINUED)
SD412B Poinsettia 61 Development
Page 2 of 2
Daily Field Report
1/13/21, Wed
Jonathan Davis
GR □UP DEL TA
FIELD MEMO
DATE: 1/13/2021 DAY: Wednesday
PROJECT NAME: Poinsettia 61 Development CLIENT: Lennar
9245 Activity Road, Suite 103
San Diego, CA 92126
Tel. (858) 536-1000
Fax (858) 536-8311
Page 1 of 1
PROJECT NUMBER: SD412B MEMO BY: Jonathan Davis, ICC#5236421
SUBJECT: Foundation Excavation Observation
Homesite No. Address Permit No. Plan Revision/Notes
102 1897 Arerrlisia Ct. CBRA2020-210 2-Alt A
103 1893 Aremisia Ct. CBRA2020-211 3B
104 1889 Aremisia Ct. CBRA2020-212 4YA
104 1891 Aremisia Ct. (ADU) CBRA2020-216 4YA
105 1885 AremiSia Ct. CBRA2020-213 IA
106 1881 Aremisia Ct. CBRA2020-214 3C
107 1877 Aremisia Ct. CBRA2020-215 2-Alt B
Reference: Gouvis Engineering (2018). Post-Tension Foundation Plans and Details for Treviso, Sheets
SN-1 to SD-3 (16 Sheets), dated August 24.
Geotechnical Report: Report of Geotechnical lnvestigation1 Poinsettia 61 Development
Carlsbad1 California
Project No. 5D411, doted November ZO, 2014
The referenced PT foundation excavations (described above, pictured below) exposed competent compacted fill. The
bearing conditions exposed are consistent with the conditions anticipated in the referenced geotechnical investigation
report and the Post Tension (PT) Model Home Plan Review. The foundation bearing soils appear to have a low expansion
potential, and are considered suitable for the support of the proposed structure. The foundation dimensions meet the
minimum geotechnical depth and width requirements. The dimensions per the referenced foundation plan are to be
verified by others.
The PT Slab subgrade contains numerous shallow plumbing trenches. Proper jetting techniques appear to have been used
to provide consolidation
NOTE: Footings should be cleaned of loose and deleterious material prior to placing concrete.
FOR GROUP DELTA INCORPORATED, BY: Jonathan Davis
SIGNATURE: ~JI:
ISO 17025 5/12/15 rev1s1on 2