Loading...
HomeMy WebLinkAbout1877 ARTEMISIA CT; ; CBRA2020-0215; PermitBuilding Permit Finaled {city of Carlsbad Residential Associated Permit Print Date: 06/11/2021 Job Address: 1877 ARTEMISIA CT, CARLSBAD, CA 92011 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2150530145 Track#: Valuation: $322,795.81 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: Construction Type: Condo CT140010 107 DEV14060 Bathrooms: Occupant Load: 4 3.0 Orig. Plan Check #: PC2020-0009 Plan Check #: PC2020-0050 Code Edition: Sprinkled: POINSETTIA 61 Permit No: CBRA2020-0215 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Finaled 12/01/2020 12/29/2020 PBurn 06/11/2021 Project Title: Description: POINSETTIA 61 (TREVISO): PHASE 14 / LOT 107 / PLAN 2 / 2,011 LIVING/ 434 SF GARAGE/ 83 SF PATIO Applicant: Property Owner: LENNAR COMMUNITIES INC ALAN CHIK 25 ENTERPRISE, # 400 ALISO VIEJO, CA 92656-2708 (949) 204-4628 LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) (949) 204-4628 COMMUNITY FACILITIES DISTRICT (CFD) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PARK IN-LIEU FEES SF DETACHED & DUPLEX: SW PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -J SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SW PPP INSPECTION FEE TIER 1 -Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM TRAFFIC IMPACT Residential Condo Outside CFD Total Fees: $30,854.47 Total Payments To Date: Building Division $30,854.47 Contractor: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 (949) 204-4628 Balance Due: AMOUNT $1,417.65 $912.97 $3,617.04 $66.00 $175.00 $92.00 $5,728.00 $182.00 $11,297.85 $13.00 $2,112.00 $998.00 $41.96 $246.00 $55.00 $3,900.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Permit Type: BLDG-Associated Permit Residenti, Application Date: Work Class: Condo Issue Date: Status: Closed -Finaled Expiration Date: IVR Number: Scheduled Date Actual Inspection Type Start Date Inspection No. Friday, June 11, 2021 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC 12/29/2020 Subdivision: 10/06/2021 Address: 1877 ARTEMISIA CT 30549 CARLSBAD, CA 92011 Inspection Primary Inspector Reinspection Inspection Status Passed Yes Yes Yes Yes Yes Page 3 of 3 -----···' '' -·--·--- # ' ~ . . _ PERMIT INSPECTION fflSTORY for (CBRA2020 .. 0215) . Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Condo Issue Date: 12/29/2020 Subdivision: Status: Closed -Finaled Expiration Date: 10/06/2021 Address: 1877 ARTEMISIA CT IVR Number: 30549 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/21/2021 01/21/2021 BLDG-11 148815-2021 Passed Chris Renfro Complete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 148816-2021 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/18/2021 02/18/2021 BLDG-14 150844-2021 Partial Pass Paul Burnette Reinspectlon Incomplete Frame/Steel/BoltlngNle !ding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/05/2021 03/05/2021 BLDG-15 Roof/ReRoof 152102-2021 Passed Tim Kersch Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/25/2021 03/25/2021 BLDG-13 Shear 153547-2021 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/09/2021 04/09/2021 BLDG-82 Drywall, 154595-2021 Passed Paul Burnette Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes 05/07/2021 05/07/2021 BLDG-Electric Meter 156836-2021 Passed Paul Burnette Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/11/2021 06/11/2021 BLDG-Final Inspection 159491-2021 Passed Chris Renfro Complete Friday, June 11, 2021 Page 2 of 3 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Condo Issue Date: 12/29/2020 Subdivision: Status: Closed -Finaled Expiration Date: 10/06/2021 Address: 1877 ARTEMISIA CT IVR Number: 30549 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Inspection Date Start Date 01/06/2021 01/06/2021 BLDG-21 147771-2021 Passed Tony Alvarado Friday, June 11, 2021 Underground/Underflo or Plumbing Checklist Item BLDG-Building Deficiency COMMENTS January 6, 2021: (virtual inspection). 1. Underground sewer waste and vent lines, under water test-approved. 2. Underground floor plumbing lines, under water test-approved. 3. Water plumbing lines, wrapped and protected, under water test-approved. 4. Scope of all underground plumbing piping and lines shaded correctly and approved per engineers plans and detail specifications BLDG~22 Sewer/Water Service 147774-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS January 6, 2021: (virtual inspection). 1. Underground sewer waste and vent lines, under water test -approved. 2. Underground floor plumbing lines, under water test-approved. 3. Water plumbing lines, wrapped and protected, under water test-approved. 4. Scope of all underground plumbing piping and lines shaded correctly and approved per engineers plans and detail specifications. BLDG-23 Gas/Test/Repairs 147636-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS January 6, 2021: (virtual inspection). 1. Underground sewer waste and vent lines. under water test -approved. 2. Underground floor plumbing lines, under water test-approved. 3. Water plumbing tines, wrapped and protected, under water test-approved. 4. Scope of all underground plumbing piping and lines shaded correctly and approved per engineers plans and detail specifications. Complete Passed Yes Complete Passed Yes Complete Passed Yes Page 1 of 3 ,, L ' Southwest Inspection and Testing, Inc. 441 Commerclal Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-6441 • Fax (562) 1146-ooz& REGISTERED INSPECTOR/AC! TECHNICIAN DAILY REPORT I SWIT Job No. r Dale; /. IQ,✓.,,.. I q J I ?' , ?, I TYPE OF I J Reinforced Concrete U Welding 1,...1 DIA/Efloxy ' INSPECTION ~ Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED Reinforced Masonry D Asphalt n Other Job Address , JU _ • -t"t...e. -Tract No. I Ph818 ~ol~ . 1.0-r - Penn~-_ Job Name , 1 17,.,, "I,<~, --r11ued By Type of Structure <.. r-J • (" _ Archltacr .. /~ Material Description (type, grade, souroe) Engineer (. ~ ,, /'I_, ~ --~ -\/4 0 _::,,. -•• / .. -Contractor 1 _ , -AJ,r- Inspector's Name r<.. /\] ,, . Subcontractor /" ;:-T -- ~ TESTS PERFORMED . SAMPLE AIR CONC WATER TIME SEllll TRUCK# TlCKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & !DENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS twELD MADE H.T. BOLTS TORQUED\ CHECKED ETC. -,---.,,__ ----~ ~ -·-· -LA..._,--. ,-~,) 0.-,.__~----·-F --,--;., --VI,<" ,/ .'h ,,~ ~ \~ ..._,,__ -~ ( .:.,,,~ -----./ J. ,1 .,..x>-, . --ic, ~ o.r , -r~J.oa ,,,,.ero:.. ?f1 O'-{ "+,::. <:" ---, *,e-r ~V\ ,e__p..::., ~.,..., !#< I ,,,,.., I -A6,-·------. , 1 • ...,.s ,C_•_-,A..-.a -·•-~ J .!$/'7 ~ ... -. , V ( t' t<..,e-? 0~ e, _\ I ,--,,r--~ I ~"2. I ~c-,-, A I? _,r£•. -I .._, .A. ,,. ,"I". I -07 lo V if:=to~ .~.oi~ • ., -If; r,::,, ,, " 1--iA<.J ( ~ -'1141 I 8 '11 ., " *0~12 <J711 / A i"' t=<" . ,e-, rr, lf:.ec.1~ • •• ~ ~ 11"-l A{ -/QO. 1 ., ~ 'fl: o?..l '-1 • 1 1:' IAJ , 2,-, " I * 0 '?'IS CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE 0 I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE R D WORK UNLESS OTHERW'8E NOTED. I HAVE TIMEIN TIMEOUT SAMPLES FOUND THIS W LY WITH THE APPROVED PLANS, SPECIFICATION, AND APPL E ION OF THE G G LAWS. Approved By ____ ~--,-..,.-c--c-;--;--,------ Project Superintendent Whtt• _ Office Copy • Canary-Accoun#ng Copy • Pink -tnspectol's Copy • Goldenrod -Jobsite Copy 0/~~ C . 'IE . -~s,£' tvl ngrneermg • 11rvey111g Certified: SDVOSB • DVBE • SBE • CPUC January 21, 2021 J.N. 14-1018-1 City of Carlsbad Building Department Attn: City of Carlsbad -Building Department 1635 Faraday Avenue Carlsbad, CA 92008 RE: Poinsettia 61-Form Certifications for Units 102 through 107 CT 14-10, Map No. 16329 City of Carlsbad Building Department, GOiay Based upon topographic surveys performed by 0' Day Consultants on January 13, 2021 for Units I 02 through I 07, the foundation forms for land development have been completed within standard tolerance (0.10 feet) in accordance with the approved plan, (City of Carlsbad DWG. 507-2C) O' Day Consultants Inc. O'DAY CONSULTANTS, INC. Very truly yours, /2.cnr-O iJar George O'Day / Project Manager 2710 Coker Avenue West, Suite 100 Carlsbad, California 92010-6609 E-mail: oday@odayconsultants.com Website: www.odayconsultants.com Tel: 760.931.7700 Fax: 760.931.8680 G:\141018\Survey\FormCertS\ 141 BA-EXHB-FormCert_ 102-107. doc GRCUPDELT.l\ 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 Project Name: Poinsettia 61 Development Project No.: SD412B Project Location: Poinsettia Lane, Carlsbad, CA Client: Lennar Homes of California Contractor: Hermanos Construction Group Delta PM: Taylor Latimer, PE TYPE OF WORK PERFORMED Soils I Earthwork EQUIPMENT USED BY CONTRACTOR(S) Backhoe DESCRIPTION OF WORK PERFORMED Location of Work: Aisle "R" -Lot #s 102, 103, 104, 105, 106, & 107 Daily Field Report Date: 1/13/21, Wed Weather: Sunny Start Time: 9:00 AM Lunch Time: n/a End Time: 12:00 PM Total Hours: 2 Work Performed: On site as requested to conduct inspection of footing subgrades at the above mentioned locations. Footing excavations were completed prior to arrival on site. Soils appeared to have been sufficiently moisture conditioned. Footing subgrade soil was examined using a soils probe and was found to be generally firm and unyielding. Accepted By: Submitted By: Signature: Signature: Name: Rick Kuzyk Name: Jonathan Davis Title: Site Superintendent Certification: ICC# 5236421 Representing (Company): Lennar Homes Group Delta Consultants, Inc. Page 1 of2 DFR v 2018.03 CiRCUP DEL T.A 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 DESCRIPTION (CONTINUED) SD412B Poinsettia 61 Development Page 2 of 2 Daily Field Report 1/13/21, Wed Jonathan Davis GR □UP DEL TA FIELD MEMO DATE: 1/13/2021 DAY: Wednesday PROJECT NAME: Poinsettia 61 Development CLIENT: Lennar 9245 Activity Road, Suite 103 San Diego, CA 92126 Tel. (858) 536-1000 Fax (858) 536-8311 Page 1 of 1 PROJECT NUMBER: SD412B MEMO BY: Jonathan Davis, ICC#5236421 SUBJECT: Foundation Excavation Observation Homesite No. Address Permit No. Plan Revision/Notes 102 1897 Arerrlisia Ct. CBRA2020-210 2-Alt A 103 1893 Aremisia Ct. CBRA2020-211 3B 104 1889 Aremisia Ct. CBRA2020-212 4YA 104 1891 Aremisia Ct. (ADU) CBRA2020-216 4YA 105 1885 AremiSia Ct. CBRA2020-213 IA 106 1881 Aremisia Ct. CBRA2020-214 3C 107 1877 Aremisia Ct. CBRA2020-215 2-Alt B Reference: Gouvis Engineering (2018). Post-Tension Foundation Plans and Details for Treviso, Sheets SN-1 to SD-3 (16 Sheets), dated August 24. Geotechnical Report: Report of Geotechnical lnvestigation1 Poinsettia 61 Development Carlsbad1 California Project No. 5D411, doted November ZO, 2014 The referenced PT foundation excavations (described above, pictured below) exposed competent compacted fill. The bearing conditions exposed are consistent with the conditions anticipated in the referenced geotechnical investigation report and the Post Tension (PT) Model Home Plan Review. The foundation bearing soils appear to have a low expansion potential, and are considered suitable for the support of the proposed structure. The foundation dimensions meet the minimum geotechnical depth and width requirements. The dimensions per the referenced foundation plan are to be verified by others. The PT Slab subgrade contains numerous shallow plumbing trenches. Proper jetting techniques appear to have been used to provide consolidation NOTE: Footings should be cleaned of loose and deleterious material prior to placing concrete. FOR GROUP DELTA INCORPORATED, BY: Jonathan Davis SIGNATURE: ~JI: ISO 17025 5/12/15 rev1s1on 2