Loading...
HomeMy WebLinkAboutPD 14-02; BURNS RESIDENCE; FINAL SOILS REPORT; 2014-08-05,, I Robert Hill EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORNIA 92071 (619) 258-7901 Fax 258-7902 229 Oceanview Drive· Vista, California 92084 August 5, 2014 Project No. 14-1106F5 Subject: Report of Field Density Tests Proposed Single-Family Residence (Burns Residence) 3330 Highland Drive Carlsbad, California 92008 References: I ."Transfer of Geotechnical Responsibility, Geotechnical Engineer of Record, Proposed Single-Family Residence (Burns Residence), 3330 Highland Drive, Carlsbad, California 92008", Project No. 14-1106F5, Prepared by East County Soil Consultation and Engineering, Inc., Dated June 26, 2014. 2. "Report of Geotechnical Investigation-Update, Scott Residence Remodel and Additions, 3320 Highland Drive, Carlsbad, California", Job No. 06-9232, Prepared by Geotechnical Exploration, Inc., Dated October 17, 2013. 3. "Report of Preliminary Geotechnical Investigation, Haig/ Scott Property, 3320 Highland Drive, Carlsbad, California", Job No. 06-9232, Prepared by Geotechnical Exploration, Inc., Dat~d July 3, 2006. Dear Mr. Hill: This is to present the results of field density tests performed on the building pads including the utility trench backfill for the proposed single-family residence and guesthouse at the subject site. In accordance with your request, in-place field density tests were performed in accordance with ASTM D1556 (Sand Cone Method). Backfill and grading were conducted between July 23 and August I, 2014 under the observation and testing of a representitive of East County Soil Consultation & Engineering Inc. The results of the field density tests are presented on Page T-1 under "Table of Test Results". The laboratory determinations of the maximum dry densities and optimum moisture contents of the fill soils are set forth on Page L-1 under "Laboratory Test Results". The approximate test locations are shown on Plate No. 1. The utility trenches were backfilled with on-site fill soils and imported base aggregate. Subgrade soils on the building pads consisting of silty sl:llld were overexcavated to a minimum depth of 3 ROBERT HILL/BURNS RESIDENCE/ HIGHLAND DRIVE PROJECT NO. 14-l 106F5 The utility trenches were backfilled with on-site fill soils and imported base aggregate. Subgrade soils on the building pads consisting of silty sand were overexcavated to a minimum depth of 3 feet below existing grade. The bottom of the excavation was scarified and recompacted. On-site fill soils were placed in thin lifts, moisture conditioned around optimum and compacted to a minimum of 95 percent relative compaction. Compaction was achieved with the use of a sheepsfoot roller, a hand whacker and a Caterpillar D6H tractor. Based on our field observations and density test results, it is our opinion that the grading operation for the proposed single-family residence and guest house was performed in accordance with the referenced geotechnical reports (References No. 2 and 3) and local grading ordinances. If we can be of further assistance, please do not hesitate to contact our office. Pages T-1, L-1 and Plate No. 1 are attached. Respectfully Submitted, Mamadou Saliou Diallo, P .E. RCE 54071, GE 2704 MSD/md 2 I TEST SOIL NO. TYPE 1 1 2 1 3 2 4 1 5 2 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 ROBERT HILL/BURNS RESIDENCE/ HIGHLAND DRIVE PROJECT NO. 14-1106F5 DEPTH OFFILL IN FEET 3 FSG AB FSG AB 2 2 1.5 1.5 1.5 1.5 3FG 3FG 3 FG 3FG 3FG PAGE T-1 TABLE OF TEST RESULTS ASTMD1556 MAXIMUM FIELD ·DRY DRY MOISTURE DENSITY DENSITY %DRYWT. P.C.F. P.C.F 9.0 123.5 130.0 6.3 124.2 130.0 10.3 0121.3 119.0 9.0 126.4 130.0 12.3 119.8 119.0 11.3 130.4 132.0 8.7 129.3 132.0 10.3 126.9 132.0 9.8 126.3 132.0 9.5 126.7 132.0 11.1 125.0 132.0 9.5 128.3 132.0 7.6 & 129.6 132.0 8.5 126.3 132.0 9.1 128.5 132.0 8.7 129.8 132.0 FSG = FINISH SUBGRADE AB = AGGREGATE BASE FG = FINISH GRADE 3 PERCENT COMPACTION 95 96 100 97 100 99 98 96 96 96 95 97 98 96 97 98 REMARKS • ROBERT H/LUBURNS RESIDENCE/ HIGHLAND DRIVE PROJECT NO. 14-1106F5 PAGE L-1 LABORATORY TEST RESULTS MAXIMUM DENSITY AND OPTIMUM MOISTURE CONTENT The maximum dry densities and optimum moisture contents of the fill materials as determined by ASTM D1557, Procedures A and B which use 25 blows of a IO-pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4-inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a 10-pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6-inch diameter 1/13.3 cubic foot compaction cylinder are presented as follows: OPTIMUM MAXIMUM MOISTURE SOIL TYPE/ DRY DENSITY CONTENT PROCEDURE DESCRIPTION (PCF) (%) 1/A TAN BROWN SILTY SAND 130.0 9.0 2/C AGGREGATE BASE (IMPORT) 119.0 11.0 3/A DARK BROWN SILTY SAND 132.0 8.5 4 l