HomeMy WebLinkAboutDWG 445-5A; PD 06-15; SOLAMAR MOBILE HOME PARK; 01-08GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER /5 J(p OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR W/>M. 00 PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. . , . . 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM RESPONSIBILITY FOR THE CORRECTION Of ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR 00 WORK IN THE PUBLIC RIGHT Of WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BF. FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT Of S 1,000,000.00 FOR EACH OCCURRENCE 0£ LIABl!,ITY. lHE INSURANCE COMPOO WRITING THE POLICY MUST HAVEll~rf".vtoi'~g,U.«;r,eAND A SIZE CATEGORY OF CIASS V AS ESTABLISHED BY "BESTS KEY RATIN GUIDE. 5. UNLESS EXEMPTED BY SECTION 301.(b)5 Of THE UNIFORM BUILDING CODE, RETAINING WALLS OUTSIDE Of PUBLIC RIGHT Of WAY REQUIRE SEPARATE PERMITS FROt.l THE BUILDING DEPARTMENT. 6. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROl.4 THE CITY AND OTHER APPROPRIATE AGENCIES. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE 00 WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL DRAWING SHALL BE RE\IISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STATE Of CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND THE " EARTHWORK SPECIFICATIONS " ATTACHED TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMlfilD TO THE PROJECT INSPECTOR. 14. A PR£CONSTRUCTION MEETING Stw I BF Hfl P AT llif SIIE PRIOR TO llif BEGINNING Of WORK AND $HAI I BF ATTENDED BY Al I Rf PRFSfNTATMS RESPONSIBLE FOR CONSTRUCTIONC INSPECTION. SUPERVISION. TESTING AND ALL OTHER ASPECTS OF DJE WORK THE ONTRACTOR SHALL REQUEST A PRECONSTRUCTION MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE(5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE AND TIME FOR THE PRECONSTRUCT!ON MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. N I INSPECTION RFOUFSTS OTHER THAN FOR PR£CONSTRUCTION MEETING WII I BF MADE BY CAIi ING llif ENGINEERING 24-HQIIR INSPECTION REOIJfSJ I INF AT .(fil9l 438-~691. INSPECTION REOUEST MUST BE RECEIYEP PRIOR TO 2:00 P-M, ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT ANO MAINTAIN ALL SAfETY DE\IICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARO OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER ANO/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF lliE PIAN VARIES FROM lliE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS. TITLE 8 CALFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BIASTING SHALL BE PERFORMED UNTIL A VALID BIASTING PERMIT HAS BEEN OBTAINED FROM THE CITY Of CARLSBAD. SUBMIT APPLICATION FOR BIASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BIASTING OPERATIONS. 19. IF ,'HY ARCHAEOLOGICAL OR PALEONTOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROl.4 THE CITY ENGINEER TO DO SO. 20. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRNAL, DEPARTURE OR OPERATION OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND 00 OTHER ASSOCIATE.D GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND SUNSET EACH DAY, MONDAY THROUGH FRIDAY AND NO EARTH MOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A UST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING Of WORK. 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. llif CONTRACTOR SHALL BE RESPONSIBLE FOR Nf'( DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDRDSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL DISTURBED SLOPES AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO. N/A , AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK Of THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS ANO THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE WITH A MINIMUM D-LOAD OF 1,350. FOR PRIVATE STORM DRAIN PIPES, UP TO 15" PVC MAY BE UTILIZED PROVIDED DEPTH IS LESS THAN 15 FEET AND BACK FILLED WITH 3/4" ROCK PER SDRSD S-4 TYPE •c• AND PIPE MEETS ASH.4 STANDARD 3034 FOR SDR 35 SOLID_ WALL PIPE. . , 3L'WHER( &t\fl:,xlSTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING' . OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVE GROUND AND UNDER GROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE, UNDERGROUND SERVICE ALERT 800 422-4133 SDG&E 800 660-7343 PACIFIC BELL 800 892-0123 ADELPHIA CABLE COMMUNICATIONS 760 438-7741 COX COMMUNICATIONS 760 806-9809 CITY OF CARLSBAD (STREETS & STORM DRAIN) 760 434-2980 •c1TY OF CARLSBAD (SEWER, WATER & RECLAIMED WATER) 760 438-2722 •SAN DIEGUITO WATER DISTRICT 760 633-2650 •LEUCADIA WASTE WATER DISTRICT 760 753-0155 PLAN SUMMARY SHEET NO. _..T,...IT..,LE ___ _ GRADING PLAN TITLE SHEET 2 LIMITS OF NCTD ACCESS/ENCROACHMENT 3 GRADING PLAN (PLAN VIEW) 4 GRADING PLAN (PLAN VIEW) 5 KEYSTONE WALL PROFILE 6 WALL CROSS-SECTIONS 7 WALL NOTES 8 WALL DETAILS SHEET INDEX !ITS WORK TO BE DONE LEGEND THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD STANDARDS 3. THIS SET OF PLANS 4. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK). 5. SOILS REPORT AND RECOMMENDATIONS BY GEOTECHNICAL EXPLORATION, INC. DATED: MARCH 3, 2005, AND LETTER OF UPDATE, DATED JULY 30, 2007, DESCRIPTION SLOPE GRADING 2:1 MAX t WALL FILL NEW KEYSTONE RETAINING WALL W/ GEOGRID (PER SEPARATE PERMIT) NEW KEYSTONE WALL FRONT VIEW (SHT 7 ONLY) REMOVE ALL EXISTING 3• AND 4" DRAINS (LOTS 68-69 & 91-95) DIRECTION OF FLOW APPROXIMATE ELEV ABOVE MSL AREA TO BE DEMOLISHED 6. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 7. WATER POLUTION CONTROL PLAN PREPARED BY: ANTHONY-TAYLOR CONSULTANTS DATED: 2/19/08 BRICK (EXISTING, SHEETS 2 AND 3) CONCRETE (EXISTING) .---------------------,-------, NEW EXTERIOR CONCRETE SLAB !a;! ::J SYMBOL y y y -- [ / I 1 I I , I I I I I ---------------- . 40,80 IXXXXI j I I f I I j I I I I I I I 1_-4.• .'•·.··~·) -.. -.. - QUANTITY 3,210 CY 4,262 SF 10 EA 700 SF 700 SF "VALLECITOS WATER DISTRICT 760 744-0460 ,-----------------------------------li'_i FENCE AS NOTED (EXISTING) LIMITS OF GRADING MONUMENT AS NOTED PROPERTY LINE (SUBDIVISION) EXISTiNG WALL • •OUVENHAIN WATER DISTRICT 760 753-6466 •BUENA SANITATION DISTRICT 760 726-1340 • AS APPROPRIATE 34. PERMIT COMPLIANCE REQUIREMENTS: A. FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS l 15.16.120.A.8! CARLSBAD MUNICIPAL CODE. B. PRIOR TO FINAL APPROVAL OF A GRADING PERMIT -THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR ! 15.16.120.A.1 Oj CARLSBAD MUNICIPAL CODE: (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS ( OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSNE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS. THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND 00 SUPPLEMENTS THERETO. (4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. 35. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLAN CHECK PLAN CHECK FEES WILL BE REQUIRED FO 00 SUCH RECHECK. 36. THE SOILS REPORTS TITLED "REPORT OF LIMITED SLOPE REPAIR INVESTIGATION", PREPARED BY GEOTECHNICAL EXPLORATION, INC., DATED MARCH 3, 2005, "REVIEW OF SLOPE STABILITY CALCULATIONS AND SOILS INVESTIGATION REPORT, AND DESIGNATION OF SOILS ENGINEER OF RECORD, SOLAMAR ESTATES EASTERLY SLOPE, CARLSBAD, CA 92009", BY ANTHONY-TAYLOR CONSULTANTS, DATED JULY 30, 2007, AND "TEMPORARY SITE EXCAVATIONS, PROPOSED KEYSTONE RETAINING WALi/SLOPE REPAIR, SOLAMAR ESTATES, EASTERLY SLOPE, CARLSBAD, CA 92009", DATED 2/21/08, PREPARED BY ANTHONY-TAYLOR CONSULTANTS SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATIONS CONTAINED IN SAID SOILS REPORT. "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. ANTHONY TAYLOR CONSULTANTS 304 ENTERPRISE STREET ESCONDIDO, CA 92029 760 7 38-8800 . BY: o(t '' 1j ~RY ~~J RCE C42590 REGISTRATION EXPIRATION DATE: 03-31-10 SOILS ENGINEER'S CERTIFICATE DATE: 9-IQ-2009 I, J ftll'-f I!. A· Cf!: /Z~OS , A REGISTERED CML ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE. WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DATES OF J}E-C & , 20 o+ AND "'lt~c/f 3 , 20..Q.L TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIO S, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. ~,,.., ~ SIGNED: G.E./P.E. NO,: __,.Z'-'0'-0---'-7 ______________ _ DATE: ?/11/zoo? LICENSE EXPIRATION DATE: _9~1/~3_0~/_I~/ __________ _ ~ L. ,1(1,~ ,;f -; N~ C 42;90 Exp. 3/31/10 CM\. OF C~\! ~ RIP-RAP OUTFALL PROTECTION (NO. 2 BACKING) SDRSD TYPE "B" BROW DITCH 18"X18" CATCH BASIN/INLET W/ BIO-FILTER 4" SOR 35 DOWN DRAIN PIPE -= -ml 4• ====== a·===== I---- 10 EACH 540 Lf 5 EACH 435 Lf 8" SCH 40 PVC INLET DOWN DRAIN 4" SOR 35 PERF. SUBDRAIN SHEET#4 ,--f.--------------------------..J 4" SDR 35 NON-PERF. WALL BACKDRAIN/SUBDRAIN OUTLETS 75 Lf 540 Lf 115 LF SHEET#3 OWNER'S CERTIFICATE I ( WE ) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTMTY ANO ADVISE ON THE COMPACTION AND STABILITY OF THIS~ 9/4~q NAME 6ATE SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY TOPOGRAPHIC SURVEY METHODS FROM INFORMATION GATHERED ON APRIL 6, 2006, BY ANTHONY TAYLOR INC. TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS, PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) APN 211-030-34.35 THE CCS NAO 83 COORDiNATES OF THIS PROJECT ARE: N 1987423.069 E 6235445.051 BENCH MARK DESCRIPTION: DRAINAGE BOX INLET LOCATION: MONUMENT IS IN A DRAINAGE BOX INLET ON THE WEST SIDE OF AVENIDA ENCINAS, 1/2 Ml. SOUTH OF PALOMAR AIRPORT ROAD, 140 FT, NORTH OF THE MOST SOUTHERLY ENTRANCE OF TREATMENT PLANT AND 1 FT. FROM CURB. RECORDED: 6/18/2001 ELEVATION: _33_,o_4_9 ___ DATUM: C'NG,v6-'~er·:·", LEGAL DESCRIPTION A PORTION OF LOT H OF RANCHO AQUA HEDIONDA IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA. ACCORDING TO A PARTITION MAP THEREOF NO. 823, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, NOVEMBER 16, 1896. NOTE: SEE CONDOMINIUM BOUNDARY PLAN DATED 11/18/87 FOR LINE OF EXCLUSNE USE/EXCLUSIVE USE TO COMMON AREA BOUNDARY. PROJECT SOIL ENGINEERS GEOTECHNICAL EXPLORATION INC. 7420 TRADE STREET SAN DIEGO, CA 92121 PHONE: (858) 549-7222 FM: (858) 549-1604 ATTN: MR. JAY HEISER OWNER/DEVELOPER SOLAMAR ESTATES HOME OWNERS ASSOCIATION c/o MS. VIVIAN STILLWELL (ON-SITE MGR.) 6532 EASY STREET CARLSBAD, CA 92011 PHONE: (760) 432-2238 FM: (760) 438-2130 EMAIL: VSOLAMAR@YAHOO,COM EARTHWORK QUANTITIES CUT: FILL: IMPORT: EXPORT: REMEDIAL: 903 CY 3 210 CY 2399 CY 92 CY 0 CY CIT'I' or OCEANSIDE ,. CITY OF £NCIHITAS VICINITY MAP "" PREPARED ON 11 /17 /08 WITH NCTD REVISIONS REINFORCED CONCRETE WALL FOOTING/CMP PIPE COVER NEW 6' HT. CHAIN LINK FENCE \ GRAVEL BASIN VEGETATED SWALE AP ANGLE POINT Clf CHAIN LINK FENCE BW BOTTOM OF WALL CMP CORRUGATED METAL PIPE CONC CONCRETE FG FL FS HP IE EG EXISTING GRADE OE BMP NOTE )( FINISH GRADE FLOW LINE FINISH SURFACE HIGH POINT INLET ELEVATION OUTLET ELEVATION THERE ARE NO REQUIRED TREATMENT CONTROL BMP'S FOR THIS PROJECT. REQUIRED TREATMENT CONTROL BMP TABLE TYPB DESCRIPTION OWNERSHIP MAINTENANCB AGREEMENT BIO-S11'ALI! GRASS UNED H.O.A. H.O.A. fflB VEGETATED SJ.ILB LANDSCAPE CONTRACTOR BIO-FILTER FLOG/.RD PLUS H.0.A. H.0.A. WITH FILTER INSERT L.!NDSCAPB CONTRACTOR SUSMP PROIECT PRIORITY --~ME=D~l=UM~-- POS TOE TOP TW @ 2 EACH 780 Lf 500 SF 210 LF POINT ON SLOPE TOE OF SLOPE TOP Of SLOPE TOP Of WALL LOCATION OF WALL CURVE SHEET NO. MAJNTENANCB FREQUENCY 4 IIONTHLY --------------------- 4 ocr. 1 & AYfER EACH STORII EVENT P~N~ DEPARTMENT APPROVAL II AS BUIL T 11 ~1 DATE:9/ZJ/:Ff (SIGNED) PLANNING DIRECTOR <l d rYl~ ¼~o EXP 3·;31-1~ (SIGNED) RECOIIIIENDED BY: lJ-in·, , l~xf 11-, ' (PRINT NAIii) DATE: 1/,»/? REVIE'w'ED BY• I DEPIJTY CITY ENGINEER 8·21./-2/JI0 DATE q.zt-10 DATE I--CCC"C=-l--~-+-----------------1f----+--+---+---1 DWN BY: ~~-DATE INlllAL ,__D_A_TE~_IN_ITI_A_L-+-_D_ATE_~IN_ITI_A_L-< CHKD BY: ~ PROJECT NO. PD 06-15 I DRA~NG NO. 445-5A ENGINEER OF WORK REVISION DESCRIPTION OlliER APPROVAL OTY APPROVAL RVWD BY: ~'/-/_ 010510 GENERAL SCOPE AND SEQUENCE 1. APPLICANT TO CONTACT NCTD (760) 967-2851, AND PROVIDE CONSTRUCTION SCHEDULE 2 WEEKS PRIOR TO COMMENCING CONSTRUCTION. ALL CONSTRUCTION WORK AND ACCESS ON NTCD PROPERlY SHALL BE PERFORMED UNDER APPROVED RIGHT-OF-ENTRY (ROE) PERMIT PROVIDED BY NORTH COUNlY TRANSIT DISTRICT. 2. ESTABLISH TEMPORARY 6' HIGH CHAIN LINK FENCE 25' FROM EDGE OF RAIL ROAD TRACK IN ORDER TO RESTRICT WORK/EQUIPMENT AREA. (REQUIRES R.R. TRACK SAFElY CLASS COMPLETION PRIOR TO WORK, AND R.R. FLAGMAN PRESENT AT TIME OF INSTALLATION) 3. TEMPORARILY REMOVE EXISTING 6' CHAIN LINK FENCE AND POSTS ALONG TOE OF SLOPE IN WORK AREA, WHERE NECESSARY. 4. CONSTRUCT NEW WALL AND RELATED DRAINAGE IMPROVEMENTS ON SOI.AMAR PROPERlY. CLEAR LOOSE SOIL/DEBRIS ANO RECOMPACT DISTURBED SOILS TO 90:1; COMPACTION ANO 2:1 SLOPE. WHERE NECESSARY, REGRADE EXISTING DRAINAGE AREA TO RE-ESTABLISH FLOW AND MATCH EXISTING UNDISTURBED GROUND. 5. RE-ESTABLISH PRE-EXISTING 6' HIGH CHAIN LINK FENCE (LIKE-IN-KIND) ALONG EASTERLY/COMMON PROPERlY BOUNDARY. 6. HYDRO SEED SLOPE AND ALL DISTURBED ON-SITE AND OFF-SITE AREAS. 7. REMOVE SAFE1Y FENCE SET AT 25' OFF TRACK. (REQUIRES R.R. TRACK SAFE1Y CLASS COMPLETION PRIOR TO WORK, AND R.R. FLAGMAN PRESENT AT TIME OF REMOVAL) 8. CONTACT NCTD PERSONNEL AND PERFORr.t FINAL CONSTRUCTION SITE WALK-THROUGH TO CONFIRr.t ADEQUATE COMPLETION OF SITE CONSTRUCTION, AND CLOSURE OF NCTD ROE PERMIT. NCTD AfNEAM NOTES 1. FOR ALL EMERGENCIES AFFECTING THE TRACK AND TRAIN SAFElY, CALL NCTD'S 24 HOUR SECURllY OFFICE AT (760) 966-6700. 2. ALL PERSONNEL ENTERING THE RAILROAD RIGHT-OF-WAY SHALL COMPLY WITH NORTH COUNlY TRANSIT DISTRICT (NCTD) REQUIREMENTS. FAILURE TO COMPLY WILL BE GROUNDS FOR TERMINATION OF WORK AND REVOCATION OF THE RIGHT-OF-ENTRY (ROE) PERMIT. 3. PRIOR TO THE START OF CONSTRUCTION AND AT THE CONTRACTOR'S EXPENSE, ALL PERSONNEL INCLUDING SUBCONTRACTORS AND THIRD PARTIES SHALL COMPLETE NCTD'S CONTRACTOR SAFE1Y TRAINING COURSE. CONTACT LEE KUHNS AT (760) 967-2851 TO ARRANGE TRAINING. 4. THE ROE PERMITTEE SHALL PAY FOR ALL FU>.GGING, INSPECTIONS, AND REVIEW COSTS />S REQUIRED IN THE ROE PERMIT. WORK BEYOND THE HOURS OF 7 Ar.t TO 5 Pr.t, MONDAY THROUGH FRIDAY, WILL BE CHARGED AT 1.5 TIMES THE STANDARD HOURLY RATE. 5. THE CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS SET FORTH BY NCTD, THE ROE PERMIT, PROJECT PLANS AND SPECIFICATIONS, ANO THE JOB SITE NCTD FLAGMAN/EMPLOYEE-IN-CHARGE(EIC). THE NCTD FLAGMAN/EiC H/>S SOLE RESPONSIBILilY TO PROTECT THE RAILROAD INFR/>STRUCTURE AND OPERATIONS. AT ALL TIMES, THE CONTRACTOR SHALL FOLLOW THE FLAGMAN/EiC'$ DIRECTION. 6. ALL PERSONS ENTERING THE RAILROAD RIGHT-OF-WAY SHALL HAVE TAKEN THE NCTD SAFE1Y TRAINING COURSE AND SHALL HAVE THE NCTD SAFElY STICKER AFFIXED TO THEIR HARD HAT. 7. NO WORK SHALL BE PERFORMED WITHIN THE RAILROAD RIGHT-OF-WAY WITHOUT A RIGHT-OF-ENTRY PERMIT, FLAG REQUESTS SUBMITTED TO NCTO, AND A NCTD FLAGMAN PRESENT DURING ALL CONSTRUCTION AND RELATED ACTMTIES. 8. THE CONTRACTOR SHALL COMPLY WITH ALL ENVIRONMENTAL AND THIRD PARlY PERMITS />S REQUIRED BY THE WORK. 9. THE C.ONTRACTOR SHALL MAKE THE. NECESS',RY ARRANGEMENTS .FOR EACH EQUIPMENT OPERATOR TO HAVE CONSTANT AND DIRECT RADIO CONTACT WITH THEIR FOREMAN. Tl-IE FOREMAN WILL IN TURN HAVE CONSTANT AND DIRECT CONTACT WITH THE NCTD FLAGMAN/EiC. 10. THE CONTRACTOR SHALL HAVE THE PERMITTED STAr.tPED SET OF PLANS ON-SITE. WORK WILL BE TERMINATED BY NCTD SHOULD NO STAMPED PLANS BE ON-SITE. 11. THE CONTRACTOR SHALL CONTACT NCTD AT (760) 967-2851 48 HOURS IN AfJI/ANCE FOR ANY INSPECTIONS REQUIRED IN THE ROE PERMIT. 12. ALL WORK ON OR ADJACENT TO THE SAN DIEGO TROLLEY SHALL ALSO ADHERE TO NCTD REQUIREMENTS. 13. THE MOVEMENT OF TRAINS IS UNPREDICTABLE. TRAINS MAY APPROACH THE JOB SITE IN ANY DIRECTION, AT ANY SPEED, AT ANY TIME, AND MAY STOP AND OCCUPY THE TRACK WITHIN TiiE CONTRACTOR'S WORK ZONE FOR AN UNDETERMINED PERIOD OF TIME. 14. NO PERSONNEL SHALL CROSS ANY TRACK WITHOUT THE APPROVAL FROM THE NCTD FLAGMAN. 15. ONLY THE NClD FLAGMAN IS PERMITTED TO PERFORr.t FLAGGING OPERATIONS WITHIN THE RAILROAD RIGHT-OF-WAY. MOBILE HOME 95 MOBILE HOME 94 r LIMITS OF NCTD ACCESS/ENCROACHMENT MOBILE HOME 93 i MOBILE HOME LEGEND --x-- I PROPERlY LINE CONTOUR MOBILE HOME 88 CHAIN LINK FENCE (EXISTING EXCEPT WHERE INDICATED) TEMPORARY 6' SAFElY FENCE WITH STAY BACK SIGNAGE PLACED AT 25' + FROr.t WESTERLY EDGE OF WESTERLY TRACK PROPOSED NEW KEYSTONE WALL CONCRETE BROW-DITCH WITH DOWN DRAINS LIMITS OF ENCROACHMENT WORK MOBILE HOME 87 PREPARED ON 11/17/08 WITH NCTD REVISIONS MOBILE HOME 69 ___;> · ---~ 3'CDNC $',/Al[ 6'CLF NCTD ACCESS NOTES 0 INSTALL (N) TEMPORARY 6' HIGH CHAIN LINK FENCE LOCATED 25FT FROM EDGE R.R. TRACKS PRIOR TO CONSTRUCTION (INSTALLATION REQUIRES R.R. FLAGMAN). ® REMOVE (E) CHAIN LINK FENCE TO ALLOW ACCESS FOR CONSTRUCTION 0 REMOVE (E) CHAIN LINK FENCE ALONG TOE OF SLOPE LOTS # 87-95 0 REGRADE DRAINAGE AREA ® UPON PROJECT COMPLETION INSTALL (N) 6' CHAIN LINK FENCE LOCATED ON PROPERlY BOUNDARY © REMOVE 6' SAFElY FENCE UPON COMPLETION OF ALL WORK (REQ R.R. FLAGMAN) P!fl!,J_!}G DEPARTMENT APPROVAL / ifal DATE: 9 /zJ /::Jt (SIGNE])) PLANNING DIRECTOR II AS BUILT" Cl ..,.;'tt cl rY1 iifl-vfl 8-Z'l-2010 DATE y;,..15 EXP, 3-3/-liJ (SIGNED) RECOIIIIOOED BY: Viris J~J.i'd•l (PRl!l'l Nil!E) REVIE\.i'ED BY, DATE I I REVJI £0 '-'ALL Uli:Jt.HT A"° At.Jr.,Nl"lsNr I S2ET I CITY OF CARLSBAD I SHEETS I S·l3ul't.T 12 rlt~Cf>,J l----+----+----------------+-----l---+---+----1 ENGINEERING DEPARTMENT 8 1-----+-----+----------------+------<---+----+----1 GRADING PLANS FOR: DA TE INlllAL DA TE INlllAL DA TE INlllAL ENGINEER OF WORK REVISION DESCRIPTION OlliER APPROVAL CITY APPROVAL SOLAMAR ESTATES SLOPE REPAIR 6532 EASY STREET, CARLSBAD, CA LIMITS OF NCTO ACCESS NCROACHMENT OWN BY:~-- CHKD BY:-~ RVWD BY:~ PROJECT NO. PD 06-15 DRAWING NO. 445-5A 010510 SPECIFIER CHART SOLIDS FILTERED TOTAL CATCH STORAGE FLOW BYPASS MODEL BASIN ID CAPACITY CUBIC FEET CAPACITY CUBIC FEET /SECOND CUBIC FEET /SECOND FG-M1818 18"X1B" 0.1 0.1 1.0 FG-M2424 24" X 24" 0.3 0.3 1.7 FG-M2436 24" X 36" 0.4 0.5 2.3 FG-M363B 36" X 36" 0.8 0.9 4.1 FG-M364B 36" X 48" 1.1 1.3 4.6 FG-M484B 48" X 48" 1.6 1.6 6.6 ADDITIONAL INLET OPTIONS CAN BE ACC□HDDATED. NOTES: 1. Inlet flume & bypass weir frame shall be constructed from stainless steel Type 304. SEE NOTE 6. 2. Matrix filter element is constructed from durable polypropylene woven monofilament geotextile surrounding a polypropylene matrix skeleton. Filter element shall not allow the retention of water between storm events. 3. Filter inserts are supplied with nclip-in" filter pouches utilizing fossil rock TM filter medium for the collection and retention of petroleum hydrocarbons (oils & greases). 4. FloGard® LoPro TM filter Inserts and fossil rock TIii filter medium pouches must be maintained in accordance with manufacturer recommendations. 5. Device requires a minimum catch basin depth of 6.50" beneath grate. See sheet 2 of 2. 6. Additional inlets are limited to one only with a 6" diameter maximum, and to a wall opposite or at a right angle to outlet. See detail A. DETAIL A ADDITIONAL INLETS SCALE: 1X OUTLET. GRATE DR SOLID COVER. L-----------~---GRATE, CBY OTHERS> INLET FLUME. --.... ----MATRIX FILTER BODY, BYPASS w'EIR ------..__ FRAME. ,-----"CLIP-IN' FOSSIL ROCK" ABSORBENT POUCH. ~-PAVEMENT SURFACE, • • • 4 ... • • . ' . • • • • • • • •• , . . . . .. • • □UTLETstE • • • • • SECTION VIEW SCALE: 2X SHALL □vl CONCRETE CATCH BASIN, (BY OTHERS) GRATE OR ----r SOLID COVER. RUBBER GASKET. ------.__ INLET FLUME, ---+-,~ 6.50' MINI BENEAT NOTE 5, 'CLIP-IN' FOSSIL ROCK" -----+-t---~ ABSORBENT POUCH. UM DEPTH GRATE. HEET 1 OF 1. PROVIDE FLOGARD LOPRO SHALLOW CATCH BASIN W/ FILTER INSERT NEW 18"X18" CONC. FG-M1818, AT ALL NEW CATCH CATCH BASIN WITH BASINS. (5 TOTAL) INSTALL PER ATRIUM GRATE DETAIL ON THIS PAGE. -~ COVER EXlERIOR BUILDING WAil < EXISTING FOOTING (WHERE PRESENT) NOTE: < - • NEW 4' THICK MIN. CONRETE SI.AB ..r-_REINFORCEO W/ NO. 3 REBAR O 18" 0.C. EACH WAY. STAGGER ALL REBAR SPLICES AND PROVIDE 24' MIN. REBAR I.AP. 12' NO. 3 REBAR DOWEL EPOXY SET 18" O.C . EMBED DOWEL A MIN. OF 6" INTO EXISTING FOOTING/SLAB, AND 12' INTO NEW SLAB SECTION, WHERE APPLICABLE. PROV[!: 2" 1H ICK lA YER OF CLEAN SAND BASE. ALL CONCRETE TO BE 2500 PSI MIN. @ 28 DAY MIX, WITH 4-INCH MAX. SLUMP. 2 DESIGN BASED ON LOW TO VERY LOW EXPANSNE SOIL INDEX FOR THE UNDERLYING SOIL MATERIALS. 3 PROVIDE SURFACE DRAIN INLETS AND SLOPE NEW SLAB @ MIN 1 % AWAY FROM BUILDING AND SLOPE INTO DRAIN INLETS. NEW EXTERIOR SLAB REPLACEMENT DETAIL NTS ~, 2D DR 2\1 D OR \I 3D OR 3\1 TY/l(FT /SEC) D = PIPE DIAMETER \I = BOTTO\/ \IIDTH OF CHANNEL SECTir A-A 2D OR 2w' RIPRAP TABLE R.OW ~"1f:~,'lf'~~RIPRAP lHICKNESS FIL 1ER BLANKET Ill 11 111-111 c'III= i=I J (MIN) SECTION B-B ROCK a.ASS THICKNESS 8" , SCH 40, PVC W/ GLUED CONNECTIONS. 1--w w I (J) NO, 2 BACKING 1.1 FT SHALL□~ CONCRETE _ _,, CATCH BASIN, SEE NOTE 5, INLET FLUME --~ \JITH RUBBER GASKET. BYPASS \.JEIR FRAME. -- MATRIX FILTER ELEMENT & ---- BYPASS v/E!R FRAME ASSEMBLY. MATRIX FILTER BODY --- 'w'ITH GE□TEXTILE COVER. "CLIP-IN "FOSSIL ROCK TM ABSORBENT POUCH. NEW FLOGARD LOPRO SHALLOW CATCH BASIN FILTER INSERT NTS \ 1. . \ X -' -r, I ( \ 1T111,r ' () \l>l'~:~! ~'._l• CATCH BASIN/BROW DITCH DETAIL NTS 3'/1' Hf_ fF, I ,E_ . ~Pel -i::,n1 r-r 1 -_] 1= v-nLL r ir_r \ . ' -\ ··:::1·' .,: I r '\l . , oc'f-~~. ~ '3\; '-lf 0:AI~ -~:: .~ /S l.24 --. y . . -Lr . J.wJ ~ 1: I LIMITS OF GRADING AS-BUil T NOTES 1. PLAN CALLS FOR D-75 TYPE "B" BROW DITCH. D-75 TYPE "A" WAS CONSTRUCTED. 2. AS-BUILT SLOPES SHOWN AS (2:1) 3. ENGINEER'I CERTIFIES THAT WALL ALIGNMENT AND HEIGHT ARE PER AS-BUILT CONDITIONS, HOWEVER, NO LIABILITY WILL BE ASSUMED FOR ANY ADDITlONAL ITEM CONSTRUCTED THAT DOES NOT CONFORM TO THE APPROVED ORIGINAL DESIGN. \ f:bi~I1~A~~ f~P PRIVATE <TO REMAIN _ eALLVITH RIP RAP BUILT AROUN TO BE REINFORCED gONPCIP~~ PROVIDE Sf£ , wALL SHT 4 FOR DETAIL AND f>RrFILE _J I u f-<( 2 I PREPARED ON 11/17/08 WITH NCTD REVISIONS R.POST R.POST REVISED WALL HEIGHT AND ALIGNMENT AS-BUILT REVISIONS RIP RAP VIER Y DISSIP Mt/RS SHALL BE DfSIGNED AS nPf 2 -SHALL BC IYTHOUr SIU.. RIPRAP 2 RIPRAP APRON DETAIL NTS CONSTRUCTION NOTES CD REMOVE AND DISPOSE OF EXISTING WALL (v REMOVE AND DISPOSE OF EXISTING CONCRETE CD REMOVE AND DISPOSE OF EXISTING CONCRETE STAIRS G) REMOVE AND DISPOSE OF EXISTING PAVERS @ REMOVE AND DISPOSE OF EXISTING CONCRETE BLOCK WALL WHERE FAILED @ NEW KEYSTONE RETAINING WALL WITH GEO-GRID REINFORCED COMPACTED FILL SLOPE ABOVE AND BELOW TO BE 2:1 (H TO V) MAX. SEE SHEET 5 FOR WALL PROFILE AND SHEETS 7 & 8 FOR KEYSTONE WALL Pl.ANS. @ REMOVE EXISTING 3• DOWN DRAINS AND REPLACE WITH NEW 4" DIA. SDR 35 PIPE. DISCHARE NEW DOWN DRAINS TO NEW BROW DITCH. @) INSTALL NEW PERFORATED 4' DIA. SDR 35 SUBDRAIN BEHIND WALL PROVIDE 4• NON-PERFORATED OUTLETS EVERY 50' HORZ. MAX, @ REPLACE EXISTING REAR YARD PATIO SLABS, WHERE DETERIORATED, DISTRESSED, OR POORLY DRAINED. (SEE DETAIL •c• ON SHT 3. @ CONSTRUCT REINFORCED CONCRETE WALL FOOTING AT EXISTING CMP DOWN DRAINS (SEE DETAIL "E" ON SHT 4). @ CONSTRUCT NEW SDRSD D-75 TYPE ·s· BROW DITCH. SEE DETAIL ·s· ON SHT 3. @ CONSTRUCT NEW 18X18 CATCH BASIN WITH a• SOR 35 PIPE DOWN DRAINED TO RIP RAP. SEE OET IL "B" ON SHT 3. WALL ALIGNMENT NOTES OJ IT] 0/S 19.89' FW FROM PROPERTY LINE (STA. 0+00) 0/S 8.83' FW FROM PROPERTY LINE (STA. 0+21.50) [}J 0/S 2.54' FW FROM PROPERTY LINE (STA. 1 +20.15) 8] ~ 0/S 2.04' FW FROM PROPERTY LINE (STA. 3+71.65) 0/S 7.34' FW FROM PROPERTY LINE (STA. 3+94.09) 0 0/S 5.94' FW FROM PROPERTY LINE (STA. 4+67,75) j 1 "=20' PLANNING DEPARTMENT APPROVAL (SIGNED) DA'fK: / / PLANNING DIRECTOR (SIGNED) DA'fK: I I RECOMIIENDED BY:---~=~~----(PRINT NAIii:) BUIL T 11 8·21/•.?<Jl(J DATE <J.zt,fo DATE CITY OF CARLSBAD ENGINEERING DEPARTMENT ,____ __ -+----,f----------------------+----+--->----f-------~ I SH3ET I DA TE INITlAL DA TE IN111AL DA TE INl11AL ENGINEER OF WORK REVISION DESCRIPTION OlHER APPROVAL CITY APPROVAL GRADING PLANS R: SOLAMAR ESTATES SLOPE REPAIR 6532 EASY STREET, CARLSBAD, CA OWN BY: CHKD BY: __ _ RVWD BY: GRADING PLAN PROJECT NO. PD 06-15 DRAWING NO. 445-5A n -.J I ' 1 CONSTRUCTION NOTES CD REMOVE AND DISPOSE OF EXISTING WALL G) REMOVE AND DISPOSE OF EXISTING CONCRETE © REMOVE AND DISPOSE OF EXISTING WOODEN STEPS t 0 REGRADE AND RECOMPACT EXISTING SLOPE TO 2:1 MAX (HORIZONTAL TO VERTICAL} @ NEW KEYSTONE RETAINING WALL WITH GEO-GRID REINFORCED COMPACTED FILL. SLOPE ABOVE AND BELOW TO BE 2: 1 (H TO V) MAX. SEE SHEET 5 FOR WALL PROFILE AND SHEETS 7 & 8 FOR KEYSTONE WALL PLANS. © REMOVE EXISTING 3• DOWN DRAINS AND REPLACE WITH NEW 4" DIA. SOR 35 PIPE. DISCHARE NEW DOWN DRAINS TO NEW TOE OF RECOMPACTED SLOPE OR TO NEW BROW DITCH. @ INSTALL NEW PERFORATED 4" DIA. SOR 35 SUBDRAIN BEHIND WALL. PROVIDE 4• NON-PERFORATED OUTLETS EVERY 50' HORZ. MAX. @ REMOVE EXISTING SOIL STOCKPILES AND (REUSE AS COMPACTED FILL, AS ALLOWED BY SOIL ENGINEERING APPROVAL). SURFACE REGRADE AREA TO DRAIN AT 1 % MINIMUM TO EXISTING LOW POINT/SWALE, ANO TO MATCH EXISTING ADJACENT UNDISTURBED GRADES. CONSTRUCT 24" WIDE, 6" HIGH COMPACTED EARTHEN BERM ALONG LOW POINT OF EXISTING GRADED AREA. PROVIDE 1 O' WIDE BY 50' LONG, GRAVEL FILTER BASIN ON UPHILL SIDE OF BERM, USING POLYESTER FILTER FABRIC, AND 4" LAYER OF 3/4" CRUSHED ROCK. REMAINING GRADED EARTHEN SWALE TO BE MAINTAINED AS SEEDED GRASS OR SOD LINED BIO-FILTERATION SWALE. @ CONSTRUCT NEW SORSO D-75 TYPE "B' BROW DITCH. SEE DETAIL "B" ON SHT 3. @) CONSTRUCT NEW 18X18 CATCH BASIN WITH 8" SOR 35 PIPE DOWN DRAINED TO RIP RAP. SEE DETAIL "B" ON SHT 3. ' LIMIIS □F'\ GRADING~, LIMITS OF GRADING 1 "=20' j5 WALL ALIGNMENT NOTES m 0/S 5.94' FW FROM PROPERlY LINE (STA. 4+67.75) (I] 0/S 14.47' FW FROM PROPERlY LINE (STA. 4+95.03) m 0/S 20.60' FW FROM PROPERTY LINE (STA. 5+01.68) EXISTING CMP ------~==3 STORMO RAIN PLAN VIEW NOT TO SCALE 12i<12" SQ #3 REBAR TIES AT 12" O.C. AT SIDE WALL ANO TOP 3" SOIL / STEEL -SEPERATION FOUR #4 REBARS (TWO _ ___J_~-L-~__J___-----4"---f---+---~~-s:?' TOP AND TWO BOTTOM} NEW KEYSTONE WALL -------~~~------1 3' MIN SEP. STEEL/SOIL EXISTING CMP PIPE 20·-22· REBAR LAP TO BE !-~i-1-40X DIA, MIN. @ SPLICES '/ ".)". "-'/ ,-.:;:'C7'C"7r-----,r-.f-----,-t-~-~~T---t-~~.,,.,/ 3" MIN CLEARANCE ///, '///'//, '/ '::-( ' ., / STEEL/SOIL I ~ C /. 's..._/ 4 ., ., "-"'' -/ ,y4M«.C7<~""''7"\"'/~,~.7/,,'.7/,,'.'/',"/',v/~;( . 12"X12" SQ-#3 24"W X24 H X 8 L REINFORCED CONCRETE REBAR TIES AT 16" BOTTOM BEAM W/FOUR #4 REBARS (TWO TOP O,C. IN FOOTING AND TWO BOTTOM) ELEVATION VIEW NOT TO SCALE REINFORCED WALL FOOTING/PIPE COVER AT EXISTING CMP DOWN DRAINS NOTE: FORM AROUND PIPE TO CREATE CONCRETE/PIPE SEPARATION. LIMt~1 '_\II ~G)'' ,' ' GRA ; . I .J...\-::G,i~ so~----,---~---~---~ IE/FL= 45.70 I N W KEYSTONE W LL W/ G O-GRIO N REINF . ..------.-. r"''" -" 40 +----f~~::=-=~==-Et---~C cc-N~C,~W~A=LL~---1 7 F OTING/PIPE PLAN VIEW -EXISTING DOWN DRAIN 'A' SCALE: 1"=15' 30 ----EXISTING 22' CMP PRIVATE STO M DRAIN ANGLE POINT C VER (RWF) 0£=29.26 f 0 EXISTING RIP RAP 20 -+-----+----+-----+------ 10-+--------+-------+------,- 0 10 20 30 PROFILE -EXISTING DOWN DRAIN •A• SCALE: 1 •=10' NEW REINF. CONC. WALL 40 -t-----+-_:,.,sc:--'~-~t-?"'J-<OOJING/J' COVER (RWF) 40 / OE=30.23 -------__ ..- -~i_;;:.<:>' ~'l EXISTING 2 " CMP PRIVATE ST RM DRAIN EXISTING RIP RAP ,P n s__ ]2,56, 20-+-----+------+-------+----------, ' i_F ft ~ 0 ~ '1- f~ii~IND~A~~ ,c~p PRIVATE 10 -+-----+----r---~1----------1 <TO REMAIN _ e w'ITH RIP RAP BUILT AR ALL TO BE REINFORCg~NCDONPCIPE), PROVIDE , w'ALL SEE SHT 4 f□R DETAIL AND PRDfILE 0 -+---·~-t---~-+----~--+---~----1 0 10 20 30 40 PLAN VIEW -EXISTING DOWN DRAIN •9• SCALE: 1'=15' PROFILE -EXISTING DOWN DRAIN •9• SCALE: 1'=10' AS·BUIL T NOTES 1. PLAN CALLS FOR 0-75 TYPE "B" BROW DITCH. D-75 TYPE "A' WAS CONSTRUCTED. 2. AS-BUILT SLOPES SHOWN AS (2:1) 3. ENGINEER~ CERTIFIES THAT WALL ALIGNMENT AND HEIGHT ARE PER AS-BUILT CONDITIONS, HOWEVER, NO LIABILllY WILL BE ASSUMED FOR ANY ITEM CONSTRUCTED THAT DOES NOT CONFORM TO THE APPROVED ORIGINAL PLAN. PREPARED ON 11/17/08 WITH NCTD REVISIONS PLANNING DEPARTMENT APPROVAL ' ----(-SIG_NED_) ----DATE: / / PLANNING DIRECTOR --~=~---+--DATE: / / (SIGNED) RECOllllENDED BY!---~=='i=~---(PRINT IWII!} REVIEw'ED BY• 1/<\ i" 42590 3/31/10 VI\. DATE ~::~~ ~~~0~Tw~~15~~~~T AND ALIGNMENT I s4HEET I CITY OF CARLSBAD I SHEETS I p_:C'L:_::_i.:_::.:_.::.:::.:_µ,,,..:.,:=---:c=:::...:.:::c:.::.c:.:.:.::__ _______ --1~--+--1-------+------1 ENGINEERING DEPARTMENT 8 >-----+--->--------------------+----+------+---+-----------< GRADING PLANS FOR: 1----t----+-------------------+-----+-----+~+-----1 SO LAMAR EST A TES SL OPE REPAIR 6532 EASY STREET, CARLSBAD, CA >---=---+=--+------------------1---+---t--=-+----< OWN B : __ _ DATE INITIAL DATE INITIAL DAT¢ INITIAL CHKD BY: __ _ ENGINEER OF 'MlRK REVISION DESCRIPTION OTHER APPROVAL Cln< APPROVAL RVWD BY: II GR ING P PROJECT . PD 06-15 DATE I DRAWING NO. 445-SA 30 - 0+00 ~ ~---t ~ -" \. . .--.. "'--. I -' 0+60 .. ----···-· ~ --~ I 0+80 --~:---~ ------------1+20 ---_____ --_ -__ ----,-l-40~----------------------1!t~o ___ ------------i+-80 ----1 · -2+00 o+ 76.11 ----~--·-, . ;. .·~ '·----·----- BOTTOM OF WALL 1 +59.48 1 +90.82 PROFILE: KEYSTONE RETAINING WALL SCALE: 1 "= 7' HORZ. 1"=7' VERT. STA 0+00 TO STA 2+00 PROFILE: KEYSTONE RETAINING WALL SCALE: 1 "= 7' HORZ. 1 "= 7' VERT. STA 2+00 TO STA 4+00 ---------- : ••"cc!.--,~ -, =~-~~ • ----<if-F ..--.-::-l -. ----~-· -~~--'--"""-,. ----==--· ............... PROFILE: KEYSTONE RETAINING WALL SCALE: 1 "= 7' HORZ. 1 "= 7' VERT. STA 4+00 TO STA 5+50 NOTE: KEYSTONE WALL CONSTRUCTION INFORMATION SHOWN FOR REFERENCE ONLY. WALL TO BE CONSTRUCTED UNDER SEPARATE PERMIT. ---------- EXISTING 22" CMP. STORMDRAIN "A" W/ REINFORCED CONC. FOOTING/PIPE COVER. (RWF) NOTE: KEYSTONE RETAINING WALL TO BE REINFORCED WITH GEO-GRID REINFORCING FABRIC EXTENDING BACK INTO 90 % COMPACTED BACKFILL. GEO-GRID FABRIC LAYERS ARE TO BE LOCATED ON TOP SURFACE OF BLOCK COURSE #1, #4, #7 AND #10. SEE WALL DETAILS SHEETS 7 AND 8. NOTE: SEE GEO-GRID TABLE ON SHEET 7 FOR GEO-GRID LENGTH, LOCATION AND TYPE. Ptr_NING DEPARTMENT APPROVAL II AS BUILT" ~> DATEFIJ33/Y't ~a,,,~ d roJe-2 a-z'l-zo,D PLANNING DIRECTOR CE '-'.1!Jl1t> EXP :2_2,_,,. . llAT.E ~ ;kx{-.,,... --=------. .:., ""-CJ.~ (SIGNED) DATE:9 /J:J/'f 1--------------1 PREPARED ON 11/17/08 WITH NCTO REVISIONS RECOMMENDED BY: {!},n's s &f,n (PRINT NAME) I DATE -~; -' J;~~li:~-A~~:;_:;;~~ND_~~c,~~'-'T. ~--------~= _T: I SH5ET I CIINiiNE~R~NG ~b~~~N~AD I SH8TS I ::;G:;::RAD::;::;:IN~G :::;P:;::LAN~S ~F::;:O R::::::· :::::::::::::::::::::::::::::===::::::==::::::::'..-'====: DATE INITIAL DA 1£ INITIAL DA 1£ INITIAL ENGINEER OF WORK REVISION DESCRIPTION 01\iER APPROVAL CITY APPROVAL SOLAMAR ESTATES SLOPE REPAIR 6532 EASY STREET, CARLSBAD, CA W LL PR PROJECT NO. I DRAWING NO. PD 06-15 _ 445-5A 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 ' -EX. MOBILE HOME LIMITS OF C EARING I & GRADII , EXISTING--• PROPERlY . WALL ·----- .. ~ .. .1 .... ""''"' ... ,, .... LINE, :~ ~- ? : ............ "'--... I . ' --...... ,...,_., ,.,_,.,.,.,. "o• •~-••• -OT-0 • ,..__ --...... 1 f'l.'W lJLt.llLJI .~ • I ,FILL ----..... • ·, "'--... ,, • • '· ----..... ,,,., . I ---.. I"\ -. , t,,TTV I • '\_-,-.. \t.,, • I ' ---. . -I '\.. '---. I • •W No • I WAtl PER-PlAN--. I ~ l., . ,___ ' I ~ -w'!R~ CTED • ICMt" • e ~ ,-.., : " -• I ·-BNG---·-- I .J ··-·~ SUB RAIN f ---../ I I r I • ' ·, • v "\. , " ,, -· '8--DAYtlGH. ~-- I (~...J ' -, SECTION A-A' KEYSTONE RETANNB WAL I <STA Q+68t SCALE: 1 "=5' HORZ. 1"=5' VERT. EX. MOBILE HOME I'-/ PROJECTED ,, • LIMITS OF LEARING • I & GMUI G • • EXIST! G-I I WALL . ...... _,,,,-NI N 2:1 SLOPE M . I _,; ll '--• ? I "-. " l~Lf~ ~ !.__rL U -~I\VU LIii ' • " ,..__ .. I ,.,c . I ~----.. I • '" " _/11.H:,. I I ' "·· FILL \ rAo.~'1 rw ....._ • ~ ' ,~ \ l.. . ' ·, ( . ilJ t'SIQl,j[_ , ... , I I " ---. 7 ' ' • ' . -" , I TEMt --' '· ~ ·----J. I I -:/ RECOMP ·-,.._ <D n, "' "TED • "Ml I SI lDRAIN I"'--.. ./ .,.._ 2: 1 SLOPE u I I <.... • ~ J I L --"?" u 5'MIN:'--rEXIST ~ ~ TO DAYLIGHT ""-' \ I,_/ - -" SECTION D::D' KEYSTotE RETAtelG WALL ISTA 2+38) IITY SH SCALE: 1"=5' HORZ. 1"=5' VERT. • LIMITS OF CLEARING I & <>1'41UING • NEW 2:1 fl SLOPE l.1AX I .. ~ ... • -, I FILL -----,n. !.STW' l ,-~ ' KE'/SfONE-Wi INEW lYPE "'a·' w,.-~ ··-~ ,BROW DITI H '\. ./ ,, ...., ..-J:>R1 PERTY Lil E 1 PIPED VIA •8-. ./ ~ .....,__ 1~.o~r,-REC Ir Y\., nrc. IU . I -~-· • T-• '· _.{;LJr I (\J:-~· "DC I S' ODRAJ" ~ , -"' O! • /PROJECT! )) /' I TO~ 1 SEE SHEt 2 / ( \ I I I f,, / ',,I I \ .. [ I'"" 8" OUTLET rv, '!IA I "' r<: ' JI-,,' -Kll-'rvv- SECTION G:G' KEYSTON; RETAINING WALL ISTA 4+6Qt SCALE: 1 "=5' HORZ. 1"=5' VERT. NG GRADE • I • I I ±-1 •. P--·r -- • MPACTf :,S[O ·- • l,J I U'IV' 1 ',r • I ' I NITH"'---. '---. 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 • I > I > '-, 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 rv I "':'II C" I U"\I .... ' ' l------+--1------+--···~-------~1--------+------•-----+-----~ - -· ~- . - ·- ~---- LIMITS OF Cl tARING SECTION B-B' KEV.STONE RETAINING WALL (STA 1+61) SCALE: 1 "=5' HORZ. 1• 5' VERT : EX. MOBILE HOME /._ PROJECTED LIMITS OF CLEARING . ~ GRADIN~---- ----·-. --. . tttW--2:,"3!:0I ["" M,..,.. . ....__ . ........,_ .,,,.---• .--~~ -··-I ·-· NEW..JYJ' • "a'.....BROYLDJ CJ:L --------. ·-. --~ ..__ @ 1.0% INIMUl.1 -1---• --...... I --PR PERlY LINE ' . ' FILL ' I A. . . \ • • \ -,.._ \j -../ 4"0.·5fW • I-• " ,-'-''EW°"Kf' i'[O~ ----1---- __( • -~ '· . NAL!c-PE -... -~ , " I •. I -.,,.DO _ ..,,-1 :RECOMI . . I 1-, • ----i / § ~ .,,. ,._ / 1£:1 -11 -··-.. --.... , •. Ar!ON BDRAI~-/ / - ---- -- ·- e-------- ----- M'.TED -~,---- ·-··-·-__ Lll,1r~ -~--s_ ·,'f. . ,r ,;. EXISTING • I G IADE . -·" -··---~ - / ' ,.'- ..J Mi... ---~ • I -:AV-l.._ \ ~ 1--· -'-J 1---··----e -~-__ , ____ ---·--f-------· -----·--·-1-------·- SECTION E-E' KEYSTONE RETAINING WALL (STA 2·+97) . SCALE: 1 "=5' HORZ. -1•-5• VERT. '\ I'-YY y -~ -EX. MOBILE HOME ' - I'\. • LIMITS OF CLEARING ~ 50 " I I!< -./ ' Z:lSI.Or """'· NEW lYI E "B" BROW / ' / . ' •' -........... DITCH@ 1.0% MINIMUM ./ 48 " I / V C '" D£.BIY.. LIJllE. : " • ' ' -;::;;-;... / ./.,, "' --46 '-I " . V/ ~ TW-'· ,..... ;, . K tiSTONE :... ............ / w LL PER • 44 ' I " '-./~~ r '" I ····--' 1---_FS 41.50 " ~ -• 42 -~-. ' ./ ,. -R "OMPACTED ·-· . 40 I ' rn D ./. _, " •• r .-2: SLOPE :,JATION '-... -EX STING GRADE • . tM: . ,(_ I I ~IMI~ MINJ 38 I . .c ./ ~ --"TO ·IAY-l-lGHT-_:::-·-------"-./ r-.. ~-57,2, i/ ------36 ···---··---··---··--·-_>, .. ·- / ' 34 ,, . ---.. ------·---·---------- / ---. ' 32 ---.. .,, ' 30 / I'----. .. / --...... -·---------L.....------·-------- SECTION H·H' KEYSTONE RETAINING WALL ISTA 6+02) " SCALE: 1 "=5' HORZ. 1"=5' VERT. A --I.. - /Nt:I. 50 48 46 44 42 40 50 48 46 44 42 40 38 36 34 32 30 50 48 46 44 42 40 38 36 34 32 30 I ,.._ 44 e----.. • 44 42 , FILL \ /l4I,, '311,, ·, ~ I 4 "\ ' PROPER LINE 42 40 r--f-=======t========t=-J• ... ·e...=--=--=--=-t:.=:"--=-~,-=--,..__~:::s,t:'~'u'>~~;;::t::;:';::;::'.trl:~~~f-~~~==-=-=1 40 f-. , NEW KEY~ TONE '-.. . , ..-> ~ , WAlc PE r=• 38 f--·---+-------+---~--1----~,~;uB~""'Nllr---. 38 : ,c, . , 35·~· 1--a"--OIJf t,Wlf, .... .,--1 36 ~-----1------+--••~--<'EXC \VATI()N-• -RIP--36 l------+----+--,'.----1•c~"Mf5·---+--+~(.-\-\,'---E ' • ,.._ MPAGT-E/u--~-1 34 • ► IN. , , / -EX! TING GRADE 34 I / , '----" , . ' ~-2:1 SLOPE ·- 32 l------+-----+--1--•--1-------¼~;y... ./ TIJ i:IA-:.'fi.l::::G::.Hc..T+----'"--+-----1 32 I ;.._ ./ ,..,. 30 1------+-----+------+-------+------+------+---1---1--------J 30 50 48 46 44 42 40 38 36 34 32 30 50 48 - - ' -- ' SECTION c-c• KEYSTONE RETAINING WALL (STA 1+815) SCALE: 1 "=5' HORZ. EX. MOBILE HOME 1• 5' VERT = / PROJECTED ·- --- • LIMITS OF CLEARING I Ill """ Im, . NEW-£:+-Sl:6 ----_,.,--. .. . I ' ~ NE .. ' r-•a~BROW-ITCH ---..!"t:Ol \llNI • ---.. ~ I . ' FILL ~,4/,1l1W '\ I "· V N. p, 0PERlY LINE . ' ---.. T I I "\ . ,.._ \ -L. ' W KEYSTONE . ' '· \ I ALL Pt1< PIAN • -;-f ..... I 'XtJ\ -1 ---.. ~ ~ "J8.0CF. I iiu1T<:: ,. I I· ... f,,,, ----• , □(9JMP.ACn:n • I s BDRAIN t --,, . I 2:1 SLOPE r " ~-./ . L... -.... ,;--I. . eftc5' IN •. ..., 1 EXI -I v-,,. ... DAYUGH ~.J I . ,~J,. " • '--"" -[ SECTION F-F' KEYSTONE RETAINING WALL (STA 3+78) SCALE: 1 "=S' HORZ. 1 "=5' VERT. . _.-' ,...- LIMITS OF CLEARING ~ING-- ~ I '-~ I ' ~ ' • • I • • . I . • I • • • I • • '-I • • • . I Tl~G GRADE I I • • I I I . . I . • . • ' 50 48 46 44 42 40 38 36 34 32 30 50 48 ' \ ) l. 46 ' ·," ,,.,---Nov, RE~ I_Mi"'/)CTlD -I "' " t2ft-., 46 ( l 44 l, ( 42 L 40 I 38 -· \.... 36 -· 34 " '-, 32 30 - --...... " . '-' I '-', . ' I ' ' I....._ " ' .. ' ' ' ' -I ----. " XISTING GRAD . " I .-:---...._ I >--· " "" ' ' -SC:::-·- '-ILL -,.._ "' I ' KEYWAY ' SECTION 1-r SLOPE RECOMPACTION SCALE: 1 "=5' HORZ. 1"=5' VERT, / _ / /. P~NINGDEPARTMENT APPROVAL yj.,n ::v~ · DATE: 9 /ZJpcf {SIGNED) PLANNING DIRECTOR 0 ,~ l-W d?,t_f,.,.. DATE: 1/cc1,;1 h (SIGNED) // "'· • I . 44 • , ; I 42 . • I I. 40 . • . 38 I I ·. I . ., 36 . J ' I I ' 34 j 32 \ 30 ( / 11 AS BUILT" 8-i'l,1010 . DATE REV!El,IED BY• RECOMIIOOED er, &,s Sed,,... q,ZJ,(-0 PREPARED ON 11/17/08 WITH NCTD REVISIONS {PRINT NAll!) J CTOR DATE r.-i---r-r-:::--:;-:-~.-------------'-----,---,---,-----,---,----'---1,.LC 1 IS IO . T•='..__ __________ ~---l---+--~--11 SH6EET I CITY OF CARLSBAD I SHEETS I ?.k4!io ~ ENGINEERING DEPARTMENT 8 o----•---+-----------------<---+---t----+---, :::;G:::::R=AD;::I;::N~G..'::P;::LAN:::;:~S::::F~O;:;R:~-::::::=:::::::::::::::::::::::::::::::::::::::=::::.'.===: 1----+-----+------------+-----+-____, SO LAMAR EST A TES SL OPE REPAIR 6532 EASY STREET, CARLSBAD, CA DA TE INITIAL DA TE INITIAL ENGINEER Of WORK REVISION DESCRIPTION OTHER APPROVAL DATE INITIAL QTY APPROVAL OWN BY: CHKD BY: -...&;-.-~cc,c-- RVWD BY: ___Q,N_ PROJECT NO. PD 06-15 DRAWING NO. 445-5A SECTION 1: GENERAL NOTES 1.01 Description: The work shall consist of furnishing and constructing Keystone/geogrld reinforced soil retaining wall systems in accordance with this technical scope of work and in reasonably close conformity with the lines, grades, and dimensions shown on the Grading Plans for Solamar Estates Slope Repair for sheets 1-10 by Anthony-To.)ior Consultants, dated 7 /9/07. 1.02 Work Included: A. Furnishing Keystone segmental concrete facing and cap units as shown on the construction drawings. B. Furnishing Strata structural geogrtd reinforcement or equivalent as shown on the construction drawings. C. Storing, cutting and placing structural geogrid reinforcement as specified herein and as shown on the construction drawings. D. Placement and compaction of unit wall fill and backfill within the geogrld reinforced area as specified herein and as shown on the construction drawings. E. Erection of Keystone segmental concrete units and placement of structural geogrld. 1.03 Reference Documents: A. Grading Plans for Solomor Slope Repair sheets 1-10 by Anthony-Ta.)ior Consultants doted 7 /9 /07. 8. Report of limited slope repair investigation. Solamar Estates Eastern Slope Area below lots 87-95 and lots 67-69 east of Easy Street, Carlsbad, CA job number 04-8826 by Geotechnicot Exploration, Inc. doted 3/3/05. C. Slope Repair design calculations Solomor Estates eastern slope area east of Easy Street, Carlsbad, CA, job number 04-8826 by Geotechnlcal Exploration, Inc. dated 8/23/07. D. Where specifications and reference documents conflict, the Engineer shall make final determination of the applicable document. 1.04 Special Provisions: A. Anthony-Ta.)ior Consultants assumes no liability for interpretation of subsurface conditions, suitability of soil design parameters and subsurface groundwater conditions made by others. 8. Anthony-Ta.)ior Consultants shall NOT be responsible for the cost of all means of subsoil improvement; cost of additional subsoil exploration; and for all labor tools, equipment and incidentals necessary to complete the work. The owner sholl be responsible for all such cost. C. The owner shall be responsible for complying with all federal, state and local requirements for execution of the work, including local building inspection and current OSHA excavation regulations. D. Prior to undertaking any grading or excavation of the site, the Contractor shall confirm the location of proposed retaining walls and all underground feotures, including utility locations within the area of construction. SECTION 2: MATERIALS 2.01 Definitions: A. Structural Geogrid-a structural geogrid formed by a regular network of integrally connected tensile elements with apertures of sufficient size to allow interlocking with surrounding soil, rock, or earth and function primarily os reinforcement. B. Segmental Concrete Facing Units-a Keystone segmental concrete facing unit, machine mode from Portland cement, water and mineral aggregates. C. Cap Unit-a Keystone segmental concrete cap unit. D. Unit Fill-granular fill which is within the segmental concrete facing units. E. Reinforced Backfill-compacted soil, which is within the reinforced soil volume as outlined on the plans. F. Foundation Soil-compacted or in-situ soil beneath the entire wall. G. Leveling Pad-a level compacted grovel footing upon which the first course of segmental concrete facing units are placed. 2.02 Base Leveling Pad Material and Unit Fill for Block: A. Base Leveling Pad Material: Material for leveling pads shall consist of compacted sand, grovel, crushed rock or any combination thereof (use USCS soil types GP, GW, SW, SP or SM), a minimum of 6 inches in thickness, constructed to the minimum dimensions shown on the construction drawings. non-reinforced concrete may be used as an alternate. B. Unit Fill: Fill for units shall consist of clean 1" minus free-draining welt graded crushed stone or granular fill, meeting the requirements of the following gradation tested in accordance with ASTM D-422: Sieve Size 1 inch 3/4 inch No. 4 No. 50 2.03 Wall Backfill: Percent Passing 100 75-100 0-10 0-5 A. Wall backfill shall consist of suitable on-site granular materials consisting of USCS types GP, GW, SW, SP or SM meeting the following gradation as determined in accordance with ASTM D-422: Sieve Size 4 inch No. 4 No. 40 No. 200 Percent Passing 100 20-100 0-60 0-35 If hand compaction methods are utilized in any portion of the wall backfill, the maximum particle size shall be limited to 3 inches. B. uses soil types CL, CH, ML, or OL shall not be used in any portion of the wall backfill including retoined materials placed beyond the reinforced zones. C. All wall backfill materials shall also have the minimum engineering properties shown in Section 4.01, Item A. D. Test results of all proposed backfill materials. Whether on-site or imported, shall be submitted to the Engineer for approval prior to construction. 2.04 Delivery, Storage and Handling: A. Structural Geogrid 1. Contractor shall check to ensure that the proper moterials have been received upon delivery. 2. All geogrids shall be stored above -20"F (29·c). 3. Contractor shall prevent excessive mud, wet cement, epoxy, and like material which may affix themselves to the grid work, from coming in contact with the geogrid material. 4. Rolled geogrid material may be laid flat or stood on end for storage. 5. Geogrlds shall be stored according to manufacturer's recommendations. B. Segmental Concrete Facing Units 1. Contractor shall check the units upon delivery to ensure that proper materials have been received. 2. Contractor shall prevent excessive mud, wet cement, epoxy, and like material from coming in contact with and affixing to the units. 3. Contractor shall protect the units from damage (i.e. cracks, chips, spoils). Damaged units shall be evaluoted for usage in the wall according to ASTM C-90 and ASTM ~-1372. 2.05 General Information: A. ICBO EVALUATION REPORT: ER-4599 B. Block Details Absorption Rate: Compression Strength: Composition: STANDARD UNIT Weight Size Exposed Face COMPAC II UNIT Weight Size Exposed Face CAP UNIT Weight Size Exposed Face PINS All Unit Types Tensile Strength Tensile Modulus Flexural Strength Tensile Modulus Short Beam Shear Strength Specific Gravity 8% (Maximum) 3000 PSI (Approximately) ·o· Slump Concrete 110 lbs. (Approximately) 8"H x 18" W x 21.S"D · 1 Square Foot (8" x 18") 82 lbs. (Approximately) 8"H X 18" W X 12"0 1 Square Foot (8" x 18") 95 lbs. (Approximately) 8"H X 18" W X 21.5"D 1 Square Foot (8" x 18") 1/2" x 5 1/4" High Strength Pultrusion Fiberglass 110,000 PSI 4 x 106 PSI 128,000 PSI 4 x 106 PSI 6,400 PSI 1.83 PSI ALL KEYSTONE UNITS COMPLY AS GRADE "N" TYPE 1, IN ACCORDANCE WITH THE 1997 USC STANDARD 21-4 SECTION 3: EXECUTION 3.01 Foundation Soil Preparation A. The foundation soil shall be excavated to the lines and grades as shown on the construction drawings. Overexcovoted areas shall be filled with compacted backfill material. Foundation soil shall be approved by a qualified Geotechnical Engineer prior to backfill and geogrid placement. - 3.02 Subgrade Preparation: A. Subgrade shall be excavated as required for placement of the leveling pad as shown on the construction drawings, or as directed by the Engineer. B. Subgrade shall be examined and approved by a qualified Geotechnical Engineer to confirm that the actual foundation conditions met or exceed assumed design assumptions. As a minimum, soil shall be proof-rolled before construction proceeds. Subgrade e;onditions not meeting the required strength shall be removed and replaced with acceptable material. C. Over-excavated areas shall be replaced with compacted granular backfill material or soils, approved by a qualified Geotechnical Engineer to the lines and grade shown on the construction drawings. 3.03 Base leveling Pad: A. Leveling Pod materials shall be placed as shown on the plans, upon undisturbed soils or compacted subgrade, to a minimum depth of 6 inches. B. Leveling Pad shall be prepared to insure complete contact of retaining wall units with the. base. C. Provided that compaction Is maintained, leveling pad materials may be extended linearly beyond the profiles shown on the plans to accommodate full-sized facing units. 3.04 Segmental Concrete Facing Unit Installation: A. The first course of Keystone segmental concrete facing units shall be placed on top of and in full contact with the leveling pod. The units shall be checked for proper elevation and alignment. B. Units shall be placed side by side for the full length of the wall. Proper alignment may be achieved with the aide of a string line or offset from baseline. C. Fiberglass connecting pins shall be installed and the voids in the units filled with tamped unit fill. D. Lay up each course insuring that pins protrude into adjoining courses above. Pull each unit forward, away from the embankment, against the pins in the previous course and backfill as the course is completed. Repeat procedure to the extent of wall height. 3.05 Cop Installation: A. Place Keystone Cap units over protecting pins from· units below. Pull forward to set b_ack position. Backfill and compact to finished grade. B. As required, provide permanent mechanical connection to wal_l units with construction adhesive or epoxy. Apply adhesive or epoxy to bottom surface of cop units and install on units below. 3.06 Structural Geogrid Installation: A. Geogrid shall be oriented with the highest strength axis perpendicular to the wall alignment. EROSION CONTROL NOTES 1. IN CASE EMERGENCY WORK IS REQU/RED,CONTACT ____________ AT _______ (PHONE NUMBER) 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING 1HE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACIUTATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. B. Geogrid reinforcement shall be placed at the elevation(s) and to the extent(s) shown J. DEVICES SHOWN ON PLANS. SHALL NOT BE MOVED OR MODIFIED W11HOUT 7HE APPROVAL on the construction drawings or as directed by the Engineer. OF 7HE ENGINEERING INSPECTOR. 4. 1HE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO 7HE SATISFACTION OF 7HE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. C. The geogrid reinforcement shall be laid horizontally on compacted backfill with 4" of vertical tolerance of the toils of grid from the front face of grid. Geogrid shall be pulled taut and anchored prior to bockfill placement on the geogrid. No tensioning of the geogrig_ moterials shall be required. · 7HE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY 7HE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. D. Geogrid reinforcements shall be continuous throughout their embedment length(s). Spliced connections between shorter pieces of geogrid will not be allowed unless pre-approved by the Engineer prior to construction. E. Tracked construction equipment shall not be operated directly upon the Geogrid reinforcement. A minimum-fill thickness of 6 inches is required prior to operation of tracked vehicles over the geogrid. Tracked vehicle turning should be kept to a minimum to prevent tracks from. displacing fill and damaging the geogrid. F. Rubber-tired equipment may pass over geogrid reinforcement at slow speeds, less than 10 mph. Sudden breaking and sharp turning shall be avoided. G. No changes to geogrid layout, including, but not limited to, length, geogrid type, or elevation, shall be made without the approval of the Engineer. 3.07 Reinforced Backfill Placement: A. Reinforced backfill shall be placed, spread, and compacted in such a manner that minimizes the development of slack in the geogrid. B. Reinforced bockfill shall be placed and compacted in lifts not to exceed 12 inches. C. Reinforced backfill shall be compacted to a minimum of 90 percent of the maximum density os determined by ASTM D-1557. The moisture content of the backfill material prior ta and during compaction shall be uniformly distributed throughout each layer and shall be within a range of 3% below, to 3% above optimum moisture content. D. Reinforced backfill shall be compacted in all areas to the lines and grades shown on the plans including all sloped areas above or between wall tiers. E. Only lightweight hand-operated compaction equipment shall be allowed within 4 feet of the face of the wall. 6. 1HE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREA TE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER 1HE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND 1HE PROJECT PERIMETER MUST DRAIN AWAY FROM 1HE FACE OF SLOPE AT 7HE CONCLUSION OF EACH WORKING DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT 1HE END OF EACH WORKING DAY WHEN 7HE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND 01HER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE Wl7H 3/4 INCH MINIMUM AGGREGRATE. 11. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, 7HE SLOPES SHALL BE STABILIZED . BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF 1HE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, STA TE OF CALIFORNIA. TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF 7HE STANDARD SPECIF/CATIONS AND 1HE FOLLOWING: A. HYDROS£EDING SHALL BE APPLIED TO: 1. ALL SLOPES THAT ARE GRADED 6: 1 (HORIZONTAL TO VERTICAL) OR STEEPER WHEN 1HEY ARE: a. 1HREE F£ET OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED FLATTER 1HAN 5: 1 WHEN ANY OF 7HE FOLLOWING CONDITIONS EXIST: a. NOT SCHEDULED FOR IMPROVEMENTS(CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. 3.08 Quality Assurance: A. The owner shall engage inspection and testing agencies, including independent laboratories, to provide quality assurance and testing services during construction project. B. of the b. IDENTIFIED BY 7HE PARKS AND RECREATION DIRECTOR AS HIGHLY VISIBLE TO 7HE PUBLIC. c. HA VE ANY SPECIAL CONDITION IDENTIFIED BY 7HE CITY ENGINEER THAT WARRANTS IMM£DIA TE TREATMENT. HYDROS£ED£D AREAS SHALL BE IRRIGATED IN ACCORDANCE WITH 1HE FOLLOWING CRITERIA: 1. ALL SLOPES 1HA T ARE GRADED 6: 1 OR STEEPER AND 7HA T ARE: a. THR£E TO £/GHT F££T IN HEIGHT SHALL BE IRRIGATED BY HAND WATERING FROM QUICK COUPLERS/HOSE BIBS OR A CONVENTIONAL SYSTEM OF LOW PR£C/PITA TION SPRINKLER HEADS PROVIDING 100% COVERAGE. B. Testing and inspection services shall be performed only by trained and experienced technicians currently qualified for the work they are to perform. b. GREA T£R THAN 8 F£ET IN HEIGHT SHALL BE WATERED BY A CONVENTION-AL SYSTEM OF LOW PR£C/P/TA TION SPRINKLER H£ADS PROVIDING 100% COVERAGE. . . 2. AREAS SLOPED L£SS THAN 6: 1 SHALL 8£ /RR/GA TED AS APPROVED BY THE CITY £NGIN£ER, PRIOR TO HYDROS££DING. THE C. The testing agency shall submit written reports to the Engineer of all inspections on a weekly basis. Such reports shall include a description of the work performed, deficiencies noted in the construction and corrective action undertaken to resolve such deficiencies. DEVELOPER SHALL SUBMIT A PROPOSED SCH£M£ TO PROVIDE /RR/GA TION TO THE Cl TY ENGIN£ER. THE PROPOSAL SHALL 8£ SPECIFIC REGARDING THE NUM8£RS, TYPES AND COSTS OF Tl-/£ ELEMENTS OF Tl-IE PROPOSED SYSTEM. The written reports will also include the location, type and results of all tests taken on C the project. · J. /RR/GA TION SHALL MAINTAIN Tl-/£ MO/S1VR£ L£\IEL OF Tl-/£ SOIL AT Tl-IE OPTIMUM LEVEL FOR Tl-IE GROWTH OF Tl-/£ HYDROS££DED GROWTH. 0. Unless otherwise directed by the Engineer or required by this technical scope of work, the type and minimum frequency of testing for soils related portions of construction will be as follows: 1. Field density tests in accordance with ASTM D-1557. $ubgrade soils-One test for every 500 to 1000 square feet of subgrade area. Base Leveling P~d-One test for every 100 lineal feet of wall length. Reinforced Backfill -One test for every 500 to 1000 square feet of backfill area at approximote heights equal to 1 /3, 2/3 and the full wall height. SECTION 4: DESIGN NOTES FOR RETAINING WALL SYSTEM :i-.01 Design Parameters: A. Oeslgn of the reinforced soil structure is based on the following parameters: Wall Segment Reinf. Backfill Ret. Backfill Foundation Friction Angle 28' 28' 26' Cohesion 0 psf 0 psf O psf Unit Weight 120 pcf 120 pcf 120 pcf Geotechnical parameters used for design should be confirmed prior to wall construction. B. Internal Stability of Walls Minimum Factor of Safety on Geogrid Strength = 1.5 Minimum Factor of Safety on Geogrid Pullout = 1.5 Percent Coverage of Geogrid = 100% C. External Stability Minimum Factor of Safety Against Base Sliding = 1.5 Minimum Factor of Safety Against Overturning = 2.0 Uniform Surcharge = Per Plan Backfill Slope = as shown on site plan D. Hydrostatic Loading None D. HYDROSEEDING MIX SHALL CONSIST OF ALL OF 7HE FOLLOWING: 1. SEED MIX SHALL CONSIST OF NO L£SS THAN: 2. J. o. 20 lbs. P£R ACRE OF ROSE CLOVER b. 20 lbs. PER ACRE OF ZORRO FESCUE c. J lbs. P£R ACRE OF E SCHOOL CIA CALIFORNICA d. 4 lbs. PER ACRE OF ACHILLEA MILLEFOLIA e. J lbs. PER ACRE OF AL YSSUM (CARPET OF SNOW) f. 1/2 lb. PER ACRE OF OIMORPHOLECA g. ITEMS c,d,e, AND f OF TI-/IS SUBSECTION MAY BE OMITTED ON LOCATIONS l'IH£RE Tl-/£ AREA 8£/NG HYDROS££D£D IS NOT h. i. j. VISIBLE FROM EITl-/£R A PUBLIC STREET OR R£$/D£NTTAL STRUC1VRES. ITEM a OF T/-1/S SU/3SECTION MUST BE INOCULA TEO IWT/-1 A NITROGEN RX/NG BACTERIA AND APPLIED DRY £/TH£R BY DRIWNG OR BROADCASTING B£FOR£ HYDROSE£DING. ALL SEED MATERIALS SHALL 8£ TRANSPORTED TO Tl-/£ JOBS/TE IN UNOP£N£D CONTAINERS WIT/-/ THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICUL1VRE C£RTIFICATION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. NON-PHYTO-TOXIC ~mNG AGENTS MAY BE ADD£D TO Tl-IE HYDROSE£D SI.URRY AT THE DISCRETION OF Tl-IE CONTRACTOR. TYPE 1 MULCH APPLIED AT Tl-IE RA TE OF NO LESS TI-/AN 2000 lbs PER ACR£. TYPE 6 MULCH (STRAW) MAY BE SUBSTl1VTED, ALL OR PART, FOR HYDRAULICALLY APPLIED Fl8£R MATERIAL l'IH£N STRAW IS USED IT MUST BE ANCHORED TO Tl-/£ SLOPE BY MECHANICALLY PUNCHING NO LESS TI-IAN 50% OF Tl-IE STRAW INTO Tl-IE SOIL. FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFA TE, 16-20-0, WIT/-/ 15% SULPHUR APPLIED AT Tl-/£ RA TE OF 500 lbs. P£R ACR£. AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEEDING BY: 1. ROUGHENING 7HE SURFACE TO BE PLANTED BY ANY OR A COMBINATION OF: a. TRACK WALKING SLOPES STEEPER THAN 6: 1 b. HARROWING AREAS 6: 1 OR FLATTER 7HA T ARE SUFFICIENTLY FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE. 2. CONDITIONING 1HE SOILS SO 7HAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT b. SA TVRA TED S£ED BED. 1HE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING OR COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR GROW7H. HYDROSEEDED AREAS SHALL BE MAINTAiNED TO PROVIDE A VIGOROUS GROWTH UNTIL Tl-IE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS l'IHERE HYDROSEEDING IS Tl-/£ PERMANENT LANDSCAPING, UNTIL Tl-/£ PROJ£CT IS COMPLETED AND ALL BONDS RELEASED. NOTE: KEYSTONE WALL CONSTRUCTION INFORMATION SHOWN FOR REFERENCE ONLY. WALL TO BE CONSTRUCTED UNDER SEPARATE PERMIT. . SECTION 5: SPECIAL INSPECTION REQUIREMENTS P1 ~NNING DEPARTMENT APP~ ~'~-~--~,_! I II AS BUil T" 5.01 Requirements A. The site soils engineer shall verify the the soil conditions are in substantial conformance with the site soils investigation report. ~NING DIRECTOR B. The site soils engineer shall verify that the base, wall sub-droinage ~TE:/ / REVIEWED BY• system, geogrid and block units are adequately installed as shown on the wall ZSIG a section at the elevations shown on the profile. 1.. J F . RECOlllll!!III BY: ' PREPARED ON 11/17/08 WITH NCTD REVISIONS _,..-·-(PRINT NAIii) ......_ Ir-l<ldS'F°CTOR C. The site soils engineer shall provide soils compaction test results, depth of :c= 8 -211-zo10 DATE CJ·Z.J•ro DATE fill, relative density and bearing values os required. ~ CITY QF C RLSBAD I SHEETS I D. A certificate of Satisfactory Completion of Work Requiring Inspection must~=-=-=-=-_:_;_-_--_-_--+----:_·_-·_·-_· ________________ -+----+-----+-·--------+--·-W ENGINEERING otARTMENT 8 be completed and submitted to the inspection Services Division. I---+---+-------------------t---+---+---+--------· ~G;RAD;;;=;;IN~G~P;LANS:::;:;:;;::::;;FO:;:::;;R:=· =============:..=::==~ ---------... --=---i-------t--- 5·02 Notes SOLAMAR EST ATES SLOPE REPAIR A. Continuous inspection is required during the performance of the work unless otherwise specified in the approved plans. B. It is the responsibility of the owner to inform inspection agency at least one working day prior requires special inspection. the special inspector or la performing any work that --+--------------------1-----+----I---_,_ -- ------>-----l 6532 EASY STREET, CARLSBAD, CA ~~~~===:===;=;;~WA~LL~~====~ ~--__ e-----i---_______________ _,___ _ _,_ _ _,_ _ ___,____ APPmVE v_~o-11c!AusER ~~ ----+---+-----+-11"1: • UJ:nt:UA'IE41W/: Eff. 3-~ _jg_ q_ · _ __ r· ________________ -+---<---______ 1-----1 ~D;:E;:PIJ~TY~C=ITY::::::EN::::G:::IN:::E=':°ER';=P:::E::::3::::30::::8::::1 :::::::EX:::P::::IR::ES:::::::'6/:::3::=0L~1;::0 =::::A::::::==: l-==-+-::=,.,--if------------------+-::-:-::=--r.=,:-,l-::=c-if-=---1 OWN BY: ---1 PROJECT NO. I DRAWING NO. DATE INITIAL DATE . INITIAL DATE INITIAL CHKD BY:___ PD 06_15 445-5A ENGINEER or WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWO BY: C\AI FINISHED GRADE (VARIES, TO 2: 1 MAX.) 4" KEYSTONE CAP UNIT PER PROFILE SEE GEO-GRID TABLE BELOW FOR GEO-GRID LENGTH, LOCATION ANO TYPE. ( RETAINED SOIL ) BACKFILL SHALL NOT EXCEED 120 LBS. PER CUBIC FOOT DRY UNIT WEIGHT ANO SHALL HAVE A MIN. SOIL FRICTION ANGLE = 28"AND COHESION = 0 PSF. COMPACT BACKFILL TO 90% MIN. PER ASTM 0-1557-91 I CONTRACTOR TO USE FRONT PINS I THE REINFORCED ZONE AND WALL SHALL BE SUPPORTED UPON A SUITABLE BEARING MATERIAL, SUCH AS A COMPACTED FILL OR BEDROCK. WALLS MAY REQUIRE DEEPER EXCAVATION IN ORDER TO PENETRATE ANY OVER-LYING UNSUITABLE MATERIAL ANO ENCOUNTER THESE "SUITABLE" MATERIALS PER THE SOILS REPORT RECOMENDA TIONS. 6"- KEYSTONE COMPAC II BLOCK UNIT 6-INCH GRAVEL LEVELING PAD; EXTEND ALONG WALL TO ACCOMMODATE BLOCK; BATTER PAD AT EACH STEP IN WALL 12" -24" Min. Section GRAVEL LEVELING PAO DETAIL REINf"oRcED s91L GRID LENGTH PER PROFIL . -... . . -. . . i---KEYSTONE COMPAC II UNIT ,1--24" MIN UNIT DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE) FINISHED GRADE AT BOTTOM OF WALL TO HAVE 2.5' MINIMUM BURIAL, ANO 5' MINIMUM TO DAYLIGHT FINISH GRADE SLOPE (VARIES, TO 2: 1 MAX.) 0 fT1 (J1 G) z I fT1 G) I -I 7J fT1 ;a 7J ;a 0 77 r;, WRAP LOVv£R COURSE OF GRAVEL BACKFILL AND 4" DIA. PERFORATED SOR 35 PIPE 4" DIA. SOR 35 SUB DRAIN OUTLET PIPE (NON-PERFORATED) @ 50' ON CENTER. Willi MIRAFI 140N FILTER FABRIC. PROv1DE FILTER FABRIC WRAP Willi 6" MINIMUM LAP AT SEAMS. 24" WIDE BY 6" THICK MIN. CONCRETE OR COMPACTED 3/4" CRUSHED STONE LEVELING PAD (FOUNDATION SOIL) FOUNDATION SOIL SHALL MEET OR EXCEED 120 LBS. UNIT WEIGHT WITH A SOIL FRICTION ANGLE lJ' = 26. AND COHESION = 0 PSF TYPICAL WALL SECTION RETAINED BACKFILL • I · GEOGRI NOT TO SCALE REINFORCED BACKFILL • I · UNIT FILL ·I EYSTONE BLOCK UNITS LIMITS OF UNIT FILL & REINFORCED BACKFILL NOT TO SCALf +I = N ..... : 00 ~ ..... ..... N Compac II Elevation 18" Compac II Plan COMPAC II UNIT NOT TO SCALE Standard Elevation ,;.:-•.~---~~--.. ;; '·\,. ·<-'·'""""'.,.,,,..,,,.,,.,.,.,.,,,,,.,.,,. :~::--;::_. , .. •.; <·-·•-•:•(::~:ti:·::••->:r;I·t· ,':-;/_._ >,·.:.: :'.;-: ··-:.,:'..~.\ .. 18" Standard Plan s·rANDARD UNIT NOT TO SCALE NOTE: PARTS OF GEOGRIO BEYOND LAST CROSS BAR ARE NOT INCLUDED IN REQUIRED MINIMUM EMBEDMENT STRATA STRUCTURAL GEOGRID OR EUIVALENT LONG AXIS OF STRUCTURAL GEOGRID APERTURE PERPENDICULAR TO WALL FACE KEYSTONE COMPAC II UNIT Check with manufacturer specifications on correct direction of orientation for geogrid to obtain proper strength. AS NEEDED, PROVIDE STEEL STAKES OR PINS TO STABILIZE GRID FROM MOVEMENT DURING INITIAL PLACEMENT OF FILL SOILS. C 0 ~ I-+-+++-+-+-+-+-+-+-+-+-+ Q Geogrid is to be Placed on Level Backfill and Extended Over the Fiberglass Pins. Place Next Unit. Pull Grid Taught and Backfill. Stake as required. GRID ANO PIN CONNECTION Soil Fill is Required Between Overlapping Geogrid . for Proper Anchorage NOT TO SCALE Place Additional Pieces of Geogrid When Angle Exceeds 20° Minimum Wall Radius: Inside Curve: Outside Curve: 4.0' (at bottom of wall) 4.0' (at top of wall) GEOGRIO INSTALLED ON CURVES NOT TO SCALE P~NING DEPARTMENT APPROVAL ~ /'k., DATE:9 PJ:R CONNECTING PINS NOT TO SCALE KEYSTONE 4" OR 8" CAP UNITS (TYP.) --,_ KEYSTONE COMPAC II UNIT (SIGNED) PLANNING DIRECTOR GEO-GRID TABLE TOTAL WALL GEO-GRID LENGTH TABLE HEIGHT LAYER NO. LOCATION LENGTli (IN FT) GRID #1 TOP OF FIRST COLRSE 7.o· 6' MAXIMUM GRID 12 TOP OF FOURTli COLRSE 7.0' -·-GRID #3 TOP OF SE'vt:Nlli COURSE 7.0' ----------------------- ' " -----------~ GRID #1 j ---_TOP_ OF FIRSTCCl\JR_SE B.o' --- 6' TO B' MAXIMUM GRID #2 I{Z; ~~:i ~~s! B.o' GRID 13------------- 6,01 ---r-----------------------GRID #4 1 TOP OF TENTli COURSE 8.0' ------------------------------------------ GRID TYPE STATA GRID 200, MIRAGRID 3XT, OR TEN SAR ex, 200. --------- STATA GRID 200, MIRAGRID 3XT, OR TEN SAR BX1200. -.. - ALL BLOCK COURSES SHOWN BELOW CAP UNIT ARE KEYSTONE COMPAC UNITS ATTACH CAP UNITS WITH CONSTRUCTION ADHESIVE OR EPOXY (USE "STAY-STUCK SS-200" OR EQUIVALENT) CAP STEP DETAIL NOT TO SCALE NOTE: KEYSTONE WALL CONSTRUCTION INFORMATION SHOWN FOR REFERENCE ONLY. WALL TO BE CONSTRUCTED UNDER SEPARATE PERMIT. _PREPARED ON 11/17/08 WITH NCTD REVISIONS DA TE INITlAL ENGINEER OF WORK REVISION DESCRIPTION ~ Aaf,.,._ DATE:9 /~/J (SIGNED) RECOMIIENDED BY· (!,,fins Sexf,,.,.. ' (PRINT NAIIE) '}-zt,10 I CTOR DATE CITY OF CARLSBAD I SHEETS I ENGINEERING DEPARTMENT 8 1----<----• GRADING PLANS FOR: ---t--" -------... " 1---J---- DA TE INITlAL DA TE INITlAL 011,ER APPROVAL CITY APPROVAL SOLAMAR ESTATES SLOPE REPAIR 6532 EASY STREET, CARLSBAD, CA DWN BY: ------I CHKD BY: &1-$1"' __ RVWO BY: GW- W I PROJECT NO. PO 06-15 I DRAWING NO. 445-5A