Loading...
HomeMy WebLinkAbout171 REDWOOD AVE; ; CBRA2019-0178; PermitBuilding Permit Finaled Ccityof Carlsbad Residential Associated Permit Print Date: 05/07/2021 Job Address: 171 REDWOOD AVE, CARLSBAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2042530100 Track#: Valuation: $491,682.31 Lot#: Occupancy Group: R3 Project#: #of Dwelling Units: 1 Plan#: Condo MS2018-0013 DEV2018-0172 Bedrooms: 4 Construction Type:VB Bathrooms: 4.5 Orig. Plan Check#: PC2019-0038 Occupant Load: Plan Check#: Code Edition: Sprinkled: Project Title: REDWOOD BEACH HOMES Description: REDWOOD BEACH HOMES: (UNIT A) 3,072 SF LIV// 450 SF GARAGE// 443 SF DECK FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: ENRIGHT LIVING 72 FREMONT PL LOS ANGELES, CA 90005 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG TRAFFIC IMPACT Residential Condo Outside CFO WATER METER FEE 1" Displacement (P) Total Fees: $20,901.72 Total Payments To Date: Building Division $20,901.72 Permit No: CBRA2019-0178 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Balance Due: Closed -Fina led 06/20/2019 01/22/2020 TAlva 05/07/2021 AMOUNT $2,017.60 $12.32 $66.00 $175.00 $92.00 $182.00 $17,208.88 $20.00 $63.92 $246.00 $764.00 $54.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for (CBRA2O19-O178) Permit Type: BLDG-Associated Permit Residentii Work Class: Condo Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Friday, May 7, 2021 Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING Issue Date: 01/22/2020 Subdivision: PALISADES Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS May 7, 2021: 1. No Building Deficiencies. 2. Structural, plumbing, electrical, and mechanical scope of work, per engineer's plans and detail specifications- Approved. 3. Verified waste management documentation, Title 24 energy compliant documentation, structural and civil final reports an final observation reports-verified and filed and city records. May 7, 2021: 1. No Building Deficiencies. 2. Structural, plumbing, electrical, and mechanical scope of work, per engineer's plans and detail specifications- Approved. 3. Verified waste management documentation, Title 24 energy compliant documentation, structural and civil final reports an final observation reports-verified and filed and city records. May 7, 2021: 1. No Building Deficiencies. 2. Structural, plumbing, electrical, and mechanical scope of work, per engineer's plans and detail specifications- Approved. 3. Verified waste management documentation, Title 24 energy compliant documentation, structural and civil final reports an final observation reports-verified and filed and city records. May 7, 2021: 1. No Building Deficiencies. 2. Structural, plumbing, electrical, and mechanical scope of work, per engineer's plans and detail specifications- Approved. 3. Verified waste management documentation, Title 24 energy compliant documentation, structural and civil final reports an final observation reports-verified and filed and city records. Passed Yes Yes Yes Yes Page 6 of 6 Permit Type: Work Class: Status: Scheduled Date 12/15/2020 12/18/2020 01/1412021 03/08/2021 05/07/2021 PERMIT INSPECTION HISTORY for (CBRA2019-0178) BLDG-Associated Permit Residenti, Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING Condo Issue Date: 01/22/2020 Subdivision: PALISADES Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Actual Start Date 12/15/2020 12/18/2020 01/14/2021 03/08/2021 Inspection Type Inspection No. Inspection Primary Inspector Status NOTES Created By TEXT Paul Burnette Video inspection BLDG-18 Exterior 146266-2020 Passed Paul Burnette Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency NOTES Created By TEXT Paul Burnette Video inspection BLDG-18 Exterior 146622-2020 Cancelled Paul Burnette Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency BLDG-23 148330-2021 Passed Paul Burnette Gas/Test/Repairs Checklist Item COMMENTS BLDG-Building Deficiency NOTES Created By TEXT Paul Burnette Video inspection BLDG-34 Rough 152210-2021 Passed Tony Alvarado Electrical Checklist Item BLDG-Building Deficiency COMMENTS March 8, 2021: (partial pass). 1. Electrical meter release of grounds wires and conductors phased and landed at Main electrical service panel bus bar-approved per engineered plans and detail specifications. 2. Released electrical meter service to SDGE. 3. Gas meter release to SDGE, and under air pressure leak test with gauge - approved. 05/07/2021 BLDG-Final Inspection 156815-2021 Passed Tony Alvarado Reinspection Created Date 12/09/2020 Passed Yes Created Date 12/15/2020 Reinspection Passed No Passed Yes Created Date 01/14/2021 Passed Yes Friday, May 7, 2021 Inspection Complete Incomplete Complete Complete Complete Page 5 of 6 PERMIT INSPECTION HISTORY for (CBRA2019-0178) Permit Type: BLDG-Associated Permit Residenti: Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING Work Class: Condo Issue Date: 01/22/2020 Subdivision: PALISADES Status: Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 11/13/2020 11/13/2020 BLDG-27 Shower 143705-2020 Cancelled Chris Ranfro Reinspection Incomplete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-84 Rough 143704-2020 Cancelled Chris Renfro Reinspect Ion Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 11/16/2020 11/16/2020 BLDG-84 Rough 143813-2020 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 11/20/2020 11/20/2020 BLDG-16 lnsulatlon 144267-2020 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency November 20, 2020: (virtual inspection). Yes 1. Title 24 Energy requirements for insulation scope of work-approved. 11/30/2020 11/30/2020 BLDG-17 Interior 144898-2020 Passed Tony Alvarado Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency November 30, 2020: (virtual inspection). Yes 1. Drywall/gypsum board type and nailing pattern -approved. 12/09/2020 12/09/2020 BLDG-17 Interior 145725-2020 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Friday, May 7, 2021 Page 4 of 6 ----~--~--- Permit Type: Work Class: Status: Scheduled Date PERMIT INSPECTION HISTORY for (CBRA2019-0178) BLDG-Associated Permit Residenti, Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING Condo Issue Date: 01/22/2020 Subdivision: PALISADES Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS July 17, 2020: 1. Not ready for third floor nailing. July 10, 2020: 1. Second floor nailing/screw down scope of work -approved. Passed Yes Yes Inspection 09/14/2020 09/14/2020 BLDG-13 Shear 138113-2020 Partial Pass Tony Alvarado Reinspection Incomplete Panels/HD (ok to wrap) Checklist Item BLDG-Building Deficiency COMMENTS September 14, 2020: 1. Exterior sheer walls -partial pass. 2. HDU-11 missing at interior shear wall location. 3. Sheaiwall/exterior wall requires titan anchor-anchor bolt spacing, missing anchor bolt. 4. Exterior bearing wall requires anchor bolt within 12 inches of bottom plate break. 5. LPT4s and A-35 metal connector clips require more nails/missing nails at metalconnector (typical). 09/1512020 09/15/2020 BLDG-83 Roof $heating, 138264-2020 Cancelled Tony Alvarado Exterior Shear (13, 15) 11/02/2020 11/02/2020 BLDG-84 Rough 142734-2020 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 11/06/2020 11/06/2020 BLDG-84 Rough 143148-2020 Friday, May 7, 2021 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Belting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Failed Paul Burnette Failed Paul Burnette Passed Yes Reinspectlon Incomplete Relnspectlon Incomplete Passed No No No No No Reinspection Incomplete Passed No No No No No Page 3 of 6 PERMIT INSPECTION HISTORY for (CBRA2019-0178) Permit Type: BLDG-Associated Permit Residenth Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING Work Class: Condo Issue Date: 01/22/2020 Subdivision: PALISADES Status: Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 02/26/2020 02/26/2020 BLDG-11 120508-2020 Failed LukeStomo Reinspectlon Incomplete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Work not ready missing holddowns multiple No locations 02/27/2020 02/27/2020 BLDG-11 120703-2020 Passed Paul Burnette Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Work not ready missing holddowns multiple Yes locations 05119/2020 05119/2020 BLDG-22 Sewer/Water 127953-2020 Passed Paul Burnette Complete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/18/2020 06/18/2020 BLDG-15 Roof/ReRoof 130487-2020 Partial Pass Tony Alvarado Reinspection Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 07/10/2020 07/10/2020 BLDG-15 Roof/ReRoof 132445-2020 Partial Pass Tony Alvarado Relnspection Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency July 10, 2020: Yes 1. Second floor nailing/screw down scope of work -approved. 07/17/2020 07/17/2020 BLOG-15 Roof/ReRoof 133072-2020 Cancelled Tony Alvarado Reinspection Incomplete (Patio) Checklist Item COMMENTS Passed BLOG-Building Deficiency July 17, 2020: No 1. Not ready for third floor nailing. BLDG-Building Deficiency July 10, 2020: Yes 1. Second floor nailing/screw down scope of work -approved. 09/11/2020 09/11/2020 BLDG-15 Roof/ReRoof 137998-2020 Passed Tim Kersch Complete (Patio) Friday, May 7, 2021 Page 2 of 6 Building Permit Inspection History Finaled ('city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2019-0178) Permit Type: BLDG-Associated Permit Residenti, Application Date: 0612012019 Owner: TRUST ENRIGHT LIVING Work Class: Condo Issue Date: 01/2212020 Subdivision: PALISADES Status: Closed -Finaled Expiration Date: 09/0712021 Address: 171 REDWOOD AVE IVR Number: 19888 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/24/2020 01/24/2020 BLDG-SW-Pre-Con 117188-2020 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/07/2020 02/07/2020 BLDG-21 118833-2020 Failed Paul York Relnspectlon Incomplete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-22 Sewer/Water 118834-2020 Failed Paul York Relnspection Incomplete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/11/2020 02/11/2020 BLDG-21 118938-2020 Passed Paul Burnette Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-22 Sewer/Water 118939-2020 Passed Paul Burnette Complete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/24/2020 02/24/2020 BLDG-11 120123-2020 Failed Paul Burnette Relnspectlon Incomplete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-12 Steel/Bond 120122-2020 Failed Paul Burnette Reinspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/25/2020 02/25/2020 BLDG-11 120299-2020 Cancelled Paul Burnette Relnspection Incomplete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No Friday, May 7, 2021 Page 1 of 6 -----·~·------·--· - DEPUTY I INSPECTION SERVICE INC. May 7, 2021 City of Carlsbad Building Department 1635 Faraday Avenue Dana Point, CA 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Permit No. CBRA2019-0178 Project Name: Redwood Beach Homes Project Address: 171 Redwood Ave This is to certify that Deputyl Inspection Service Inc. was employed to perform special inspection on the above-mentioned project at the above address, which required continuous inspection per Section 1701 of California Building Code for Reinforced Concrete and Wood Construction. Based on special inspectors and materials testing written reports of this work, it is my judgment that the inspected work was performed to the best of my knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. Signature: {;Md 8~ Chad Brummel Dana Point-INSP0S-0013 Deputy 1 Inspection Service, Inc. An IAS Accredited Agency ACCREDITED 638 Camino De Los Mares, Suite 8130-482, San Clemente, CA 92673 1-800-DEPUTYl Office/Fax (949) 859-8788 -OJINSULATION, L.P. ~ Insulation rrcpJaccs Insulation Certificate Fed. Id# 205576054 Lic.#888804 Job No: :4838423 Your Home/Building has been Insulated with Certainteed Fiberglass Insulation products, which are designed for today's safety standards and tomorrow's energy requirements. Fiberglass Is inorganlc and therefore permanently noncombustible, so ,t does not have to be treated with fire-retardant chemlcals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will It settle over time as many other Insulation materials. This al:;g certifi~that Certainteed AbecoJass Insulation has bes:n professiooanv Installed In this home'bvild1ng to provide the following thermal performance and meets Iltle 24 reau]lements. Insulation Is Installed In the structure desoibed below as follows: Work Area Celling Area Vaulted Celling Vaulted Ceiling Garage to l.Ning Walls Exterior Walls and Rim Joists Knee Walls Garage With LMng Area Above Overhang/Cantilevered Areas Voids Below Tubs/Showers Caulk and Seal exterior doors, windows and sill plates Interior Wall 2x4 Interior Wall 2x6 Between Aoor Area Job Name: Redwood Beach Homes Item Installed R-30 16" x 48• -Unfaced -Batts FS Rigid Board 1 • R·25 16" x 96" • Unfaced • Batts R· 13 15" x 10s· • Unfaced -Batts R-21 16" x 96" • Unfaced • Batts R-13 15" x 105" • Unfaced • Batts R-19 15" x 48" • Unfaced -Batts R-19 1S" x 48" • Unfaced • Batts R-11 15" x 105" • Unfaced • Batts CF812 Foam R· 11 15" x 105" • Unfaced • Batts R·19 15" x 48" • Unfaced • Batts R·19 15" x 48" • Unfaced Job Address: A: 171 Redwood Ave car!sbad, CA 92008 • Expandable Foam caulking to meet liUe 24 Air Infiltration Standards ts Included Signed ru Sonia sttYa-ontract Administrator Date: November 30, 2020 433 928 908 226 2,888 171 418 202 56 3,069 2669 106 1,503 R· Means resistance to heat now. The higher the R·value, the greater the Insulating power. Ask. yoor boddcr f0< the fact sheet on R·values. Keep ttus certlflalte with your other valued papers. Jf you ever sen this home/buildlng, thls certificate should be passed on to the buyer. Azusa Branch #872 600 S V1nccnt Ave Azusa, CA 91702 Phone: (626) 812-6070 Palm Springs Branch #873, #87G 72-060 Corporate Way Thousand Palms, CA 92276 Phone:(760)834-3355 Escondido Branch #874 2061 Aldergrove Ave Escondido, CA 92029 Phone:(760)839-3200