HomeMy WebLinkAbout171 REDWOOD AVE; ; CBRA2019-0178; PermitBuilding Permit Finaled
Ccityof
Carlsbad
Residential Associated Permit
Print Date: 05/07/2021
Job Address: 171 REDWOOD AVE, CARLSBAD, CA 92008
Permit Type: BLDG-Associated Permit Residential Work Class:
Parcel#: 2042530100 Track#:
Valuation: $491,682.31 Lot#:
Occupancy Group: R3 Project#:
#of Dwelling Units: 1 Plan#:
Condo
MS2018-0013
DEV2018-0172
Bedrooms: 4 Construction Type:VB
Bathrooms: 4.5 Orig. Plan Check#: PC2019-0038
Occupant Load: Plan Check#:
Code Edition:
Sprinkled:
Project Title: REDWOOD BEACH HOMES
Description: REDWOOD BEACH HOMES: (UNIT A) 3,072 SF LIV// 450 SF GARAGE// 443 SF DECK
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
ENRIGHT LIVING
72 FREMONT PL
LOS ANGELES, CA 90005
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFO
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
TRAFFIC IMPACT Residential Condo Outside CFO
WATER METER FEE 1" Displacement (P)
Total Fees: $20,901.72 Total Payments To Date:
Building Division
$20,901.72
Permit No: CBRA2019-0178
Status:
Applied:
Issued:
Fina led Close Out:
Inspector:
Final Inspection:
Balance Due:
Closed -Fina led
06/20/2019
01/22/2020
TAlva
05/07/2021
AMOUNT
$2,017.60
$12.32
$66.00
$175.00
$92.00
$182.00
$17,208.88
$20.00
$63.92
$246.00
$764.00
$54.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY for (CBRA2O19-O178)
Permit Type: BLDG-Associated Permit Residentii
Work Class: Condo
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Friday, May 7, 2021
Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING
Issue Date: 01/22/2020 Subdivision: PALISADES
Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
COMMENTS
May 7, 2021:
1. No Building Deficiencies.
2. Structural, plumbing, electrical, and
mechanical scope of work, per engineer's
plans and detail specifications-
Approved.
3. Verified waste management
documentation, Title 24 energy compliant
documentation, structural and civil final
reports an final observation
reports-verified and filed and city records.
May 7, 2021:
1. No Building Deficiencies.
2. Structural, plumbing, electrical, and
mechanical scope of work, per engineer's
plans and detail specifications-
Approved.
3. Verified waste management
documentation, Title 24 energy compliant
documentation, structural and civil final
reports an final observation
reports-verified and filed and city records.
May 7, 2021:
1. No Building Deficiencies.
2. Structural, plumbing, electrical, and
mechanical scope of work, per engineer's
plans and detail specifications-
Approved.
3. Verified waste management
documentation, Title 24 energy compliant
documentation, structural and civil final
reports an final observation
reports-verified and filed and city records.
May 7, 2021:
1. No Building Deficiencies.
2. Structural, plumbing, electrical, and
mechanical scope of work, per engineer's
plans and detail specifications-
Approved.
3. Verified waste management
documentation, Title 24 energy compliant
documentation, structural and civil final
reports an final observation
reports-verified and filed and city records.
Passed
Yes
Yes
Yes
Yes
Page 6 of 6
Permit Type:
Work Class:
Status:
Scheduled
Date
12/15/2020
12/18/2020
01/1412021
03/08/2021
05/07/2021
PERMIT INSPECTION HISTORY for (CBRA2019-0178)
BLDG-Associated Permit Residenti, Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING
Condo Issue Date: 01/22/2020 Subdivision: PALISADES
Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Actual
Start Date
12/15/2020
12/18/2020
01/14/2021
03/08/2021
Inspection Type Inspection No. Inspection Primary Inspector
Status
NOTES Created By TEXT
Paul Burnette Video inspection
BLDG-18 Exterior 146266-2020 Passed Paul Burnette
Lath/Drywall
Checklist Item COMMENTS
BLDG-Building Deficiency
NOTES Created By TEXT
Paul Burnette Video inspection
BLDG-18 Exterior 146622-2020 Cancelled Paul Burnette
Lath/Drywall
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-23 148330-2021 Passed Paul Burnette
Gas/Test/Repairs
Checklist Item COMMENTS
BLDG-Building Deficiency
NOTES Created By TEXT
Paul Burnette Video inspection
BLDG-34 Rough 152210-2021 Passed Tony Alvarado
Electrical
Checklist Item
BLDG-Building Deficiency
COMMENTS
March 8, 2021: (partial pass).
1. Electrical meter release of grounds
wires and conductors phased and landed
at Main electrical service panel bus
bar-approved per engineered plans and
detail specifications.
2. Released electrical meter service to
SDGE.
3. Gas meter release to SDGE, and under
air pressure leak test with gauge -
approved.
05/07/2021 BLDG-Final Inspection 156815-2021 Passed Tony Alvarado
Reinspection
Created Date
12/09/2020
Passed
Yes
Created Date
12/15/2020
Reinspection
Passed
No
Passed
Yes
Created Date
01/14/2021
Passed
Yes
Friday, May 7, 2021
Inspection
Complete
Incomplete
Complete
Complete
Complete
Page 5 of 6
PERMIT INSPECTION HISTORY for (CBRA2019-0178)
Permit Type: BLDG-Associated Permit Residenti: Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING
Work Class: Condo Issue Date: 01/22/2020 Subdivision: PALISADES
Status: Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
11/13/2020 11/13/2020 BLDG-27 Shower 143705-2020 Cancelled Chris Ranfro Reinspection Incomplete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-84 Rough 143704-2020 Cancelled Chris Renfro Reinspect Ion Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
11/16/2020 11/16/2020 BLDG-84 Rough 143813-2020 Passed Paul Burnette Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
11/20/2020 11/20/2020 BLDG-16 lnsulatlon 144267-2020 Passed Tony Alvarado Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency November 20, 2020: (virtual inspection). Yes
1. Title 24 Energy requirements for
insulation scope of work-approved.
11/30/2020 11/30/2020 BLDG-17 Interior 144898-2020 Passed Tony Alvarado Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency November 30, 2020: (virtual inspection). Yes
1. Drywall/gypsum board type and nailing
pattern -approved.
12/09/2020 12/09/2020 BLDG-17 Interior 145725-2020 Passed Paul Burnette Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Friday, May 7, 2021 Page 4 of 6
----~--~---
Permit Type:
Work Class:
Status:
Scheduled
Date
PERMIT INSPECTION HISTORY for (CBRA2019-0178)
BLDG-Associated Permit Residenti, Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING
Condo Issue Date: 01/22/2020 Subdivision: PALISADES
Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection
Start Date
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
Status
COMMENTS
July 17, 2020:
1. Not ready for third floor nailing.
July 10, 2020:
1. Second floor nailing/screw down scope
of work -approved.
Passed
Yes
Yes
Inspection
09/14/2020 09/14/2020 BLDG-13 Shear 138113-2020 Partial Pass Tony Alvarado Reinspection Incomplete
Panels/HD (ok to wrap)
Checklist Item
BLDG-Building Deficiency
COMMENTS
September 14, 2020:
1. Exterior sheer walls -partial pass.
2. HDU-11 missing at interior shear wall
location.
3. Sheaiwall/exterior wall requires titan
anchor-anchor bolt spacing, missing
anchor bolt.
4. Exterior bearing wall requires anchor
bolt within 12 inches of bottom plate break.
5. LPT4s and A-35 metal connector clips
require more nails/missing nails at
metalconnector (typical).
09/1512020 09/15/2020 BLDG-83 Roof $heating, 138264-2020 Cancelled Tony Alvarado
Exterior Shear (13, 15)
11/02/2020 11/02/2020 BLDG-84 Rough 142734-2020
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
11/06/2020 11/06/2020 BLDG-84 Rough 143148-2020
Friday, May 7, 2021
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Belting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Failed Paul Burnette
Failed Paul Burnette
Passed
Yes
Reinspectlon Incomplete
Relnspectlon Incomplete
Passed
No
No
No
No
No
Reinspection Incomplete
Passed
No
No
No
No
No
Page 3 of 6
PERMIT INSPECTION HISTORY for (CBRA2019-0178)
Permit Type: BLDG-Associated Permit Residenth Application Date: 06/20/2019 Owner: TRUST ENRIGHT LIVING
Work Class: Condo Issue Date: 01/22/2020 Subdivision: PALISADES
Status: Closed -Finaled Expiration Date: 09/07/2021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
02/26/2020 02/26/2020 BLDG-11 120508-2020 Failed LukeStomo Reinspectlon Incomplete
Foundation/Fig/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Work not ready missing holddowns multiple No
locations
02/27/2020 02/27/2020 BLDG-11 120703-2020 Passed Paul Burnette Complete
Foundation/Fig/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Work not ready missing holddowns multiple Yes
locations
05119/2020 05119/2020 BLDG-22 Sewer/Water 127953-2020 Passed Paul Burnette Complete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/18/2020 06/18/2020 BLDG-15 Roof/ReRoof 130487-2020 Partial Pass Tony Alvarado Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
07/10/2020 07/10/2020 BLDG-15 Roof/ReRoof 132445-2020 Partial Pass Tony Alvarado Relnspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency July 10, 2020: Yes
1. Second floor nailing/screw down scope
of work -approved.
07/17/2020 07/17/2020 BLOG-15 Roof/ReRoof 133072-2020 Cancelled Tony Alvarado Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency July 17, 2020: No
1. Not ready for third floor nailing.
BLDG-Building Deficiency July 10, 2020: Yes
1. Second floor nailing/screw down scope
of work -approved.
09/11/2020 09/11/2020 BLDG-15 Roof/ReRoof 137998-2020 Passed Tim Kersch Complete
(Patio)
Friday, May 7, 2021 Page 2 of 6
Building Permit Inspection History Finaled
('city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBRA2019-0178)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 0612012019 Owner: TRUST ENRIGHT LIVING
Work Class: Condo Issue Date: 01/2212020 Subdivision: PALISADES
Status: Closed -Finaled Expiration Date: 09/0712021 Address: 171 REDWOOD AVE
IVR Number: 19888 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/24/2020 01/24/2020 BLDG-SW-Pre-Con 117188-2020 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/07/2020 02/07/2020 BLDG-21 118833-2020 Failed Paul York Relnspectlon Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-22 Sewer/Water 118834-2020 Failed Paul York Relnspection Incomplete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
02/11/2020 02/11/2020 BLDG-21 118938-2020 Passed Paul Burnette Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-22 Sewer/Water 118939-2020 Passed Paul Burnette Complete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/24/2020 02/24/2020 BLDG-11 120123-2020 Failed Paul Burnette Relnspectlon Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-12 Steel/Bond 120122-2020 Failed Paul Burnette Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
02/25/2020 02/25/2020 BLDG-11 120299-2020 Cancelled Paul Burnette Relnspection Incomplete
Foundation/Fig/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
Friday, May 7, 2021 Page 1 of 6
-----·~·------·--· -
DEPUTY I INSPECTION SERVICE INC.
May 7, 2021
City of Carlsbad
Building Department
1635 Faraday Avenue
Dana Point, CA 92008
SPECIAL INSPECTOR'S FINAL PROJECT REPORT
Permit No. CBRA2019-0178
Project Name: Redwood Beach Homes
Project Address: 171 Redwood Ave
This is to certify that Deputyl Inspection Service Inc. was employed to perform special
inspection on the above-mentioned project at the above address, which required continuous
inspection per Section 1701 of California Building Code for Reinforced Concrete and Wood
Construction.
Based on special inspectors and materials testing written reports of this work, it is my
judgment that the inspected work was performed to the best of my knowledge, in
accordance with the approved plans, specifications and applicable workmanship provision of
the California Building Code.
Signature: {;Md 8~
Chad Brummel
Dana Point-INSP0S-0013
Deputy 1 Inspection Service, Inc.
An IAS Accredited Agency
ACCREDITED
638 Camino De Los Mares, Suite 8130-482, San Clemente, CA 92673
1-800-DEPUTYl Office/Fax (949) 859-8788
-OJINSULATION, L.P. ~ Insulation rrcpJaccs
Insulation Certificate
Fed. Id# 205576054
Lic.#888804
Job No: :4838423
Your Home/Building has been Insulated with Certainteed Fiberglass Insulation products, which are designed for today's safety
standards and tomorrow's energy requirements. Fiberglass Is inorganlc and therefore permanently noncombustible, so ,t does
not have to be treated with fire-retardant chemlcals that will likely lose their effectiveness over time. It has not been treated
with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will It settle over time as many other
Insulation materials.
This al:;g certifi~that Certainteed AbecoJass Insulation has bes:n professiooanv Installed In this home'bvild1ng to provide the
following thermal performance and meets Iltle 24 reau]lements.
Insulation Is Installed In the structure desoibed below as follows:
Work Area
Celling Area
Vaulted Celling
Vaulted Ceiling
Garage to l.Ning Walls
Exterior Walls and Rim Joists
Knee Walls
Garage With LMng Area Above
Overhang/Cantilevered Areas
Voids Below Tubs/Showers
Caulk and Seal exterior doors, windows and sill plates
Interior Wall 2x4
Interior Wall 2x6
Between Aoor Area
Job Name: Redwood Beach Homes
Item Installed
R-30 16" x 48• -Unfaced -Batts
FS Rigid Board 1 •
R·25 16" x 96" • Unfaced • Batts
R· 13 15" x 10s· • Unfaced -Batts
R-21 16" x 96" • Unfaced • Batts
R-13 15" x 105" • Unfaced • Batts
R-19 15" x 48" • Unfaced -Batts
R-19 1S" x 48" • Unfaced • Batts
R-11 15" x 105" • Unfaced • Batts
CF812 Foam
R· 11 15" x 105" • Unfaced • Batts
R·19 15" x 48" • Unfaced • Batts
R·19 15" x 48" • Unfaced
Job Address: A: 171 Redwood Ave car!sbad, CA 92008
• Expandable Foam caulking to meet liUe 24 Air Infiltration Standards ts Included
Signed ru
Sonia sttYa-ontract Administrator
Date: November 30, 2020
433
928
908
226
2,888
171
418
202
56
3,069
2669
106
1,503
R· Means resistance to heat now. The higher the R·value, the greater the Insulating power. Ask. yoor boddcr f0< the fact sheet on R·values.
Keep ttus certlflalte with your other valued papers. Jf you ever sen this home/buildlng, thls certificate should be passed on to the buyer.
Azusa Branch #872
600 S V1nccnt Ave
Azusa, CA 91702
Phone: (626) 812-6070
Palm Springs Branch #873, #87G
72-060 Corporate Way
Thousand Palms, CA 92276
Phone:(760)834-3355
Escondido Branch #874
2061 Aldergrove Ave
Escondido, CA 92029
Phone:(760)839-3200