Loading...
HomeMy WebLinkAboutDWG 422-7L; CUP 05-03; LA COSTA LOT 1.3 RV PARKING; 01-14L A C 0 s T A G R N s RV PARKING MORROW Dt;Vt;LOPMt;NT LANDSCAPI;: IMPROVl;:Ml;:NT PLANS Al)DITIONAL NOT~S: 1. At I 11,lllGATION BACKl'LOW PRtVENTtRS SHALL 81:; IDTtO BY A C!;llTl!'ll;o TtSTE:R ANO RtSUL TS MUST Bt GIVc"I TO THG CITY ANO THI; CARLSBAD MUNICIPAL WATtR OISTIIICT. PIP!. 81.TWI.I.NT THI. ME:TtR AND BACKFLOW PR!;VE;NTtR SHALL BE 'SCHEDULE K HARD COPPER". APPROVED CONTRACT !lACKROW T(;STE;RS CAN BE: l'OUND ON nu; CITY WE:B SITE; AT WWW.C1.CAllLSBAD.CA.US/PDf'DOC.HTML?PID•342 2. WATH1 \COVICt (POINT Of' CONNE:CTION) INSTALLATION, Tl,MPORARV OR PERMANENT, SHALL BE IN Pl /\f:' DINCIDE WITH PLANTING TIMING SPECIFIE:D IN SECTION L 3-1. 3. PRIOR IO !HE: START OF GRADING, THE APPLICANT OR APPLICANTS AGENT SHALL OBTAIN CITY APPROVAL OF A CONSTRUCTION SCHEDULE AND/OR EXHIBIT OUTLINING THE TIMING OF THE SLOP!a PLANTING · \ID IRRIGATION. THE SCHtDULt SHALL SHOW TIMING OF CONSTRUCTION OF FRi;E-STAND!:~G. RtTAINING AND CRIB WALL IMMtDIATtL V AFTER ROUGH GRADING AS tACH LOCATION IS ACHIEVE!) JqRJCA TION ANO PLANTING SHALL TAKE PLACE AS GRADING PROGRESSESS. 4. INSTALLATION OF IRRIGATION AS SHOWN ON THE APPROVED PLANS SHALL COMMENCE WITHIN 10 DAYS 01' THE TIME WHEN EACH SLOPE: IS BROUGHT TO GRAD!; AS SHOWN ON THE; APPROVE;O GRADING ,,oo THI; l'OLLOWING NOTE; TO THt CQV!;R SHE:E;T, "LANTING AND IRRIGATION FOR nu; SLOPE: ARE:AS SI-IALL BE: COMPLtTtl y INSTALLE:D, AS SHOWN ON THE APPROVtO PLANS, WITHIN 30 DAYS Al'TE:R THt; IRRIGATION INSTALLATION FIRST COMMENCES VICINITY ROAD CITY OF E;NCINIT AS M A P PROJE::CT SITE:: II CITYOI= SAN MARCOS LOCATION M A P ..J ~,.1--- 1.3 PROJECT SITE G2ROAD ALICANTE: ROAD r MASTER TENTATIVE _/ -MAP BOUNDARY ALICANTE ROAD t-~OSCAPc- DE:CLARATION 01= RE:SPONSIBLE CHARGE: I Hi;Ri;BY D!;CLAR!; THAT I AM TH!; LIC!;NS!;D D!;SIGN!;R 01= WORK FOR THIS PROJ!;CT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DE:FINED IN SECTION 6703 Ot= THE BUSINESS AND PROFESSIONS CODE, AND THAT THE D!;SIGN IS CONSISTENT WITH CURRENT ST AND ARDS. I UNDERSTAND THAT THE CHECK Ot= PROJECT DRAWINGS AND SPl:CIFICA TIONS BY THE CITY Ot= CARLSBAD AND THE SAN Dll~GO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH IS CONFINED TO REVIEW ONLY AND DOtS NOT Rtlll:VE Mt, AS THt LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESJ;. PLANS HAVE BEE;N PREPARED IN SUBSTANTIAL CONl=ORMANCE WITH THE APPROVED LANDSCAP!o CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS 01= APPROVAL RELA TtD TO LANDSCAPING. INTl:GRA TION DE;SIGN STUDIO 5411 AVENIDA E;NCINAS, SUITE; 270 CARLSBAD, CA 92008 BY, '4ew--LARRY SHE;EHAN RLA 3180 • EXP 31 oi;:c 01 DATE;, (,l\.0] INTEGRATION p L A N D A T Ii /f <I' -~~o -.:::,.._,~ C> _, ... [a iiiiiiiliiiil DE:SIGN STUDIO 160ct06 ist Submittal R '= V I s I 0 N s LANDSCAPE ARCHITECTS 7 Dec06 2nd Submittal 5411 Avenlda Gncina.s_ Suite 270 19 Deco6 3rd Submittal Carl•bad. CA 92006.4360 10Jano1 Final Submittal t 760.602.0144 f 76M02.0388 www.lNTEGAATION-DE;SIGN.com DATE 1N!T!AL ENGINEER or WORI CUPOS-03 G E N E R A L N O T E S THE F;JLLOWING GENERAL NOTES ARE PROVIDl;D BY THE LANDSCAPE ARCHITECT TO GIVE DIRECTIONS TO THE CONTRACTOR. THE <.::ITV ENGINEER'S SIGNATURE ON THESE PLANS DOES NOT CONSTITUTE APPROVAL OF ANY OF THESE NOTES AND THE CITY WILL NOT BE RESPONSIBLE FOR THEIR ENFORCEMENT. l. THE CONTRACTOR SHALL VERIFY WITI-I Tl-IE OWNrn'S RE;PRESENTATIVE THAT PLANS ARE CURRENT AND APPROVED. 2 WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF CARLSBAD. 3. THESE PLANS ARE BASED ON GRADING PLANS BY HUNSAKER ASSOCIATES 4. THESE PLANS ARE BASED ON IMPROVEMENT PLANS BY HUNSAKER ASSOCIATES 5. THESE PLANS ARE BASED ON Df!V UTILITY PLANS BY UTILITY SPECIALISTS 6. THE ENGINEERING SOILS REPORT IS A PART OF THESE 15. SITE OBSERVATION MEETINGS SHALL INCLUDE, A. PR~-CONSTRUCTION MEETING B. REVIEW OF HAROSCAPE S,\MPLES C. FINAL GRADING D. LA VOUT OF HARDSCAPE ELEMENTS E. SELECTION OF PLANT MATERIALS F. IRRIGATION G. PLANTING H. APPROVAL TO BEGIN tST ABLISHMENT PtRIOD I. ACCEPTANCE ot= ESTABLISHMENT PERIOD NOTo, 'LANDSCAPE' SHALL REFER TO ALL IMPROVEMENTS WITHIN THIS SET OF DOCUMENTS THAT HAVE BEEN DESIGNED BY THIS OFFICE. CONTRACTORSHALLBEBACKCHARGtDFORLANDSCAPE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL COMPL V WITHTHE REPORTS RECOMMENDATIONS AS THCY RELATE TO I-IIS WORK. 16. ARCHITECTS TIME WHtN OBSERVATIONS ARE CALLED FOR ANO 1rs FOUND THAT THE WORK IS NOT SIGNIFICANTLY RliADV UPON OBSERVATION OR THE APPOINTMENT IS NOT KePT. TIME WILL BE CHARGED ON AN HOURLY BASIS. PLUS TRANSPORTATION, FOOD AND LODGING COSTS. AT THE CURRENT HOURLY RATE FOR THE PERSONNEL PROVIDING THE OBSERVATIONS. 17. THIS FIRM DOES NOT PRACTICE OR CONSULT IN THE FIELD OF SAFETY ENGINEERING. THIS FIRM DOES NOT DIRECT Tl-IE CONTRACTOR'S OPERATIONS AND IS NOT RESPONSIBLE FOR THE SAFETY OF PERSONNE:l OTHER TI-IAN OUR OWN ON SITE. THE SAFETY OF OTHERS IS Tl-IE R!;SPONSIBILITV OF THE CONTRACTOR. Tl-IE CONTRACTOR SHOULD NOTIFY THE OWNER IF HE OR SME CONSIDERS ANY OF THE RECOMMENDED ACTIONS PRESENTED HEREIN TO BE UNSAFE. 7. Tl-IE CONTRACTOR SHALL OBTAIN ALL NECESSARY AND REQUIRED PERMITS AND PAV ALL RELATED FEES AND/OR TAXES REQUIRED TO INSTALL THE WORK ON THeSE PLANS. 8. THE CONTRACTOR SHALL BE APPROPRIATELY LICENSED AS REQUIRED BY THE STATE. IN WHICH THt WORK TAKES PLACE. 9. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING THE WORK AND SHALL B• R!;SPONSIBLE FOR COORDINATING WITH THE OWNER. LANDSCAPE ARCHITECT. GOVERNING AGENCl!;S AND OTHER TRADES. 10. THE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY OF ANY ERRORS, OMISSIONS Oil DISCREPANCIES IN EXISTING CONDITIONS OR WITI-IIN THE PLANS PRIOR TO BEGINNING THE WORK. 11. UNIT ' 'RICES FOR ALL IMPROVEMENTS SHALL BE ESTABLISHED AS A PAI f OF THE CONTRACT WITH THE PROJECT OWNER AND PRIOR TO Bl '.,INNING WORK. TO ACCOMMODATE ADDITIONS AND/OR DELE' IONS OF MATERIAL AND LABOR. 12. DETE. Ml NATION OF "!;QUAL" SUBSTITUTIONS SHALL BE MADE ONLY BY H ;LANDSCAPE ARCHITECT. 13. THE L .WDSCAPE ARCHITECT SHALL BE NOTIFIED NO LESS THAN 481-l( ~RS IN ADVANCE OF ANY SITE OBSERVATIONS OR MEETINGS. 14. SITE ( BSERVATIONS BY THE LANDSCAPE ARCHITECT DURING ANY PHAS OF THIS PROJECT DOES NOT RELIEVE Tl-IE CONTRACTOR OF HI , PRIMARY RESPONSIBILITY TO PERFORM ALL WORK IN ACC( RDANCE WITH THE PLANS. SPECIFICATIONS AND GOVERNING coocs. s ~ E ~ Sheet Number 1 2 3 4 5 6 7 thru 8 9 thru 10 11 12 13 14 ., P' ... -----·~· . ~ . T DATE INITIAL DATE 1a THIS PROJECT CONTAINS 15,472 S.F. OF LANDSCAPE AReA. ALL LANDSCAPED AREA WILL BE PRIVATELY MAINTAINED. 19. A SEPARATE GRADING PJ;:RMi"f WILL BE REQUIRED FOR ALL 1-!ARDSCAPE IMPROVEMENTS. HARDSCAPE IMPROVEMENTS ARE NOT PART OF n-nsPERMIT. 20. REFERENCE DOCUMENTS, UNLESS OTHERWISE NOTED OR SPECIFIED, THE WORK SHALL BE DONE IN ACCORDANCE WITH Tl-I£ FOLLOWING REF£RENCE DOCUMS:NTS WHICH ARE ON FILE IN THE OFFICE OF THo CITY CLERK OR OFFICE OF Tl-IE STATE ARCI-IITECT, 1. "STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION", 1986 EDITION (DOCUMENT NO. 769709) 2 CITY OF CARLSBAD LANDSCAPE MANUAL 3. "AMERICANS WITH DISABILITIES ACT' 4. TITLE 24 HANDIC,\PPED COOJ;: BEFORE EXCAVATION, VERIFVTI-IE LOCATION OF UNDERGROUND UTILITIES. OIGAL£RT (UNDERGROUND SERVICES ALERT) 1 (800) 422-4133 20. INSPECTION PROCEDURES, I INSPECTION OF THE PROJtCT SHALL BE PERFORMED BY THE LANDSCAPE ARCHITECT OF THE WORK, OR HIS D!;SIGNA TED AGENT. RE,FER TO THE SPECIFICATIONS FOR THE SCHoDULE OF REQUIRED INSPECTIONS AND REQUIRED SU BM ITT ALS. FOLLOWING COMPL!;TION OF THI; WORK, THE LANDSCAPE ARCHITECT OF THE WORK WILL CERTil'V THAT THE INSTALLATION H/1.S BEeN COMPLHED B SUBMITTING THE "FINAL LANDSCAPE CERTIFICATION FORM". A R£QUEST FO A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE. N "FINAL LANDSCAPE CERTIFICATION FORM" FAX TO, 760.944-6?43 LANDSCAPE INSPECTION REQUEST PHONE LINE, 760-602-4602 D E X Sheet Description Landscape Title Sheet -LT -1 Landscape Reclaimed Water Title Sheet L T-2 Landscape Construction Plan and Details • LCl Landscape Construction Specifications -LC-2 Landscape Irrigation Plans -Ll-1 Landscape Irrigation Legend and Notes -Ll-2 Landscape Irrigation Details -Ll-3 thru Ll-4 Landscape Irrigation Specifications -Ll-5 thru Ll-6 Landscape Tree Planting Plan -L TP-l Landscape Shrub Planting Plan -LSP-1 Landscape Planting Details LP-2 Landscape Planting Specifications LP-3 APPROVED FOR IRRIGATION AND PLAN11NG ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. REV!~ -/ 2J. -v) j tJ.n ,-gu1· ' . ___ {•17•07 ENGl~EERING PLANCHECKefZ. DATE I SH;ET I CARLSBAD r--~,~:~ EFTS CITY OF ' 14 ' PLANNING DEPARTMENT I LANDSCAPE TITLE SHEET: LA COSTA LOT 1.3 RV PARKING I APH~1~Dr er-aJ.:;;t! l-)"t..o1 I -·--PLANNING DATE DWN BY, PROJECT NO. DRAWING NO. INITIAL CHKO BY: REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY, CUP05-03 442-7L ,- ' 1-____________________________ ....,__ _____________________________________________________________________________________________________________ ...J ...J 7\,'(}05 P R O J [ G T s\05JJ08 lo Costo RV\Orowin9 files\CD's\TJTI£.dwg\SHT~1\9 don 2007 8:55 AM by: Sfofom3 GENERAL NOTES RE;CYCLtD WATtR NOTE;S SIGNAGE NOTES CUPOS-03 LA COSTA GRttNS RV PARKING (PRIVATt) 1. ALL WORK SHALL Bl. DONE; IN ACCORDANCE; WITH THE CARLSBAD MUNICIPAL 1. THt FOLLOWING GUIDELINtS FOR THt USE OF RI.CYCLED WATER ARI. TO Bl: DECLARATION OF RESPONIBLE CHARGE WA Tl:R DISTRICTS RULl:S AND Rl:GULA TIONS FOR CONSTRUCTION OF RtCYCLE;D WATE;R MAINS DA Tl:D OCTOBi,R 1993. 2. DRINKING FOUNTAINS SHALL Bl: PROTtCTED FROM SPAY OF Rl:CYCLED WATE:R. Bl.ST MANAGEMENT PRACTICES SHALL BE USl,D TO MINIMIZI, Ri,CYCLtD WATI.R 1,NCROACHME:NT ON PUBLIC FACILITll:S SUCf-1 AS PICNIC TABLES, BBQ'S, PLAYGROUNDS, SAND TOT LOTS, l:TC. 3. 4. 5. 6. 7. a.• 9. 10. 11. 12. 13. 14. 15. 16. BEST MANAGl,MtNT PRACTICE:S SHALL BE USl,D TO ELIMINATI, OR CONTROL TO THI, BEST l,l(Tt;;NT POSSIBLE; PONDING, RUN-OFF, OVERSPRA Y AND MISTING. HOSt BIBS ARE STRICTLY PROf-llBITtD. ON.SITE CROSS-CONN!.CTIONS B!;TWJ;;E;N RECYCLED WA TJ;;R LINtS AND PORTABLE WATE:R LINl,S ARE; STRICTLY PROHIBITl,D. NO SUBSTITUTION OF PIPE MATtRIALS WILL Bia ALLOWED WITHOUT PRIOR APPROVAL OF THE CARLSBAD MUNICIPAL WATER DISTRICT. ALL ON SITE;: PIPt SHALL HAVG. WARNING TAPE; PG.R CARLSBAD MUNICIPAL WATG.R DISTRICT RULES AND RE;GULATIONS. THE IRRIGATION SYSTtM SHALL RUN BE:TWE:E:N THE: HOURS OF 10.00PM AND 6:00 AM THG. FOLLOWING MORNING (SPOT IRRIGATION COULD BE: DONE AT A DIFFE;RleNT TIME WITH QUALIFIED SUPE;RVISION PERSONNtL ON SIT!:.) PROVIDE; A MINIMUM OF AT Ll:AST 18 INCHES OF COVER OVl:R All WIRING AND PIPING. NON-DESIGNATtD US!. ARtAS SHALL Bt PROTE:CTE;D FROM CONTACT WITH Rt;;CYCLtD WATt:R, WHl:THtR BY WINDBLOWN SPRAY OR BY DIRtCT APPLICATION THROUGH IRRIGATION OR OTHtR USE LACK OJ: PROTECTION, WHtRE BY DI.SIGN, CONSTRUCTION PRACTICE; OR SYSTt;:M OPE;RATION, IS STRICTLY PROHIBITED. IRRIGATION 1-11:ADS SHALL B!; RE;LOCA TE;D OR ADJUSTE;D TO PRE;VtNT OVtR SPRAYING ON SIDEWALKS, STREETS AND NON-Dl:SIGNATtD USt ARI.AS. RE;CYCLED WATE:R QUICK COUPLING VALVES SHALL 81. OJ: A TYPE; DESIGNtD FOR THE US!: ON RECYCLtD WATER DISTRIBUTION SYSTtMS (SPIK!;S NOT !NTE;RCHANGtABLE; WITH POTABLE; WATl:R QUICK COUPLl:R SPIKES PtR CARLSBAD WA TI.R DISTRICT'S RULE;$ AND RJ;;GULATIONS. Ml:TERS SHALL BE; SIZI.D BY THE CITY OJ: CARLSBAD MUNICIPAL WATl:R DISTRICT. ALL IRRIGATION PIPl:S SHALL BE; STtNCILJ;D WITH THI: WARNING, "NON-POTABLE; OR RECYCLED WATl:R", COLOR-CODED (PURPLE;) AND LAID WITH WARNING TAP!: AND STENCILING ORll:NTI.D TOWARD THE TOP OF Tl-It TRENCH PtR THE CARLSBAD WATE;R DISTRICT'S RUltS AND REGULATIONS. ALL POTABLE WATE;R AND Rl:CYCLtD WATtR PIPING SHALL BE INSTALLtD WITH THI: STENCILING orm,NTE;D TOWARD THE TOP OF THE TRI.NCH. WHEN POTABLE WA TtR LINt AND RI.CYCLE:D WATG.R UNI: CROSS, THI: l!tCYCLE:D UN!; SHALL BE INSTALLl:D WITHIN A PROTtCTIVE SLtEV!a. THt SLEtVE SHALL EXTGND 10 FE!aT FROM tACH SIDE:, FROM THE CE;NTl:R LINt OF POTABLE; LINE;, FOi! A TOTAL 01= 20 FE;E;T. 17. A 10 FOOT HORIZONTAL Sl:PARATION BJ;;TWI.EN POTABLE: WATl:R AND RtCYCLl:D WATE;R MAINS MUST St MAINTAINJ;;D AT ALL TIMtS. Tl-It POTABLI. LINES MUST BE: INSTALLtD ABOVt THt RECYCLtD UNI:. 18. A MINIMUM OF 12 INCHES OF VE;RTICAL SE:PARATION BITWE;E;N UTILITIES MUST Bl. MAINTAINE;DAT ALL TIMES. 19.• Dl:VtLOPE;R / CONTRACTOR SHALL CONDUCT A CROSS-CONNE;CTION TEST AND COVI.RAGt Tl.ST AS DIRECTE;D BY THE; CARLSBAD MUNICIPAL WATE;R DISTRICT GNGINtE:R AND THE; SAN DltGO COUNTY Dl:PARTME;NT OF tNVIRONMtNTAL HI.AL TH PRIOR TO ANY usi; OF RE:CLAIME:D WATtR. 20. QUICK COUPLING VALVES UStD IN RE.CYCLED WA TE;R SYSTEMS SHALL CONFORM TO THE FOLLOWING, A. RECYCLED WATtR -QUICK COUPLING VALUl:S UStD IN RECYCLl:D WATER SYSTtMS Sl-!ALL HAVE ACMt TYPE TI-IRtADS AND PURPLE: COLORE;D LOCKING COVl:RS PE;RMANtNTL YA TT ACHE,D TO THI. VALVE:. QUICK COUPLING VALVtS SHALL Bl: NtLSON NO. 7645, f-lUNTtR NO. HVIOO-RL-NP OR APPROVtD EQUAL (SPIKES SHALL NOT BE: INTtRCHANGtABLI. WITH POTABLE; WATl:R QUICK COUPltR SPIK(;S). 21. Tf-lE RtQUIRl:D CROSS-CONNl:CTION INSPECTION SHALL Bl: DONE; BY THt CARLSBAD MUNICIPAL WATER DISTRICT AND THI: SAN DIE;GO COUNTYDtPARTMtNT OF ENVIRONMtNT AL HEALTH. COPltS OF INSPECTION REPORTS WILL BE: FORWARDtD TO Tl-It NON-INSPl:CTING PARTY. 22. DtVELOPI.R SHALL SHOW THt LOCATION OF R.C. SIGNS 'DO NOT DRINK" ON TH!eSE; PLANS. 23.' AN ON-SITt UStR / SUPERVISOR Sf-lALL BE: DE::SIGNATED IN WRITING, THIS INDIVIDUAL SI-IALL Bt FAMILIAR WITH PLUMBING SVSTtMS WITHIN THI: PROPtRTY, WITH THE; BASIC CONCtPTS OF BACKFLOW / CROSS CONNECTION PROTE:CTION, AND THE SPE:CIFIC REQUIRl:MENTS OF A R!eCYCLtD WATER SYSTE:M. COPltS OF THE Dl:SIGNA TION, WITH CONTACT PHONt NUMBE;RS SHALL BE PROVID(;D TO THE SAN DIEGO COUNTY DtPARTMJ;;NT OF tNVIRONMl:NT AL Hl:AL Tl-I AND CARLSBAD MUNICIPAL WATER DISTRICT. MIKE LOMBARDI AT {760) 505-5644 OR AFT!;R HOURS CONTACT MIKE: LOMBARDI AT (760) 505-5644 24. SHOW ALL PUBLIC AND PRIVATE POTABLE; WA TE:R MAINS ON IMPl!OVE;ME;NT PLANS. •1TtMS 8, 19, & 23 SHALL Bt RI.QUIRED JUST PRIOR TO Tl-II: ACTUAL USt OF RI.CYCLED WATER. •ITEMS 22 THI. SIGNAGE SHALL BE A PART OF THIS I.P. BUT Tl-It ACTUAL SIGNS AND TAGS WILL Bl: INSTALLE:D JUST PRIOR TO ACTUAL USE: OF RECYCLED WATER. 25. ON RECYCLED WATE;R SYSTtMS, ALL APPURTE:NANCES (SPRINKLER HEADS, VALVE; BOXf;S, ETC.) SHALL Bl: COLOR-CODE;O PURPLE; PE;R AWWA GUIDELINES AND StCTION 116815 OF THE CALIFORNIA HE;ALTI-I AND SAFE;TY CODE. 1. 2. 3. 4. 5. 6. 7. 8. PERMANl:NTL Y POSTl:D INSIDI. THt DOOR OF tACH CONTROLLtR WHERE: THEY ARE: E:ASIL Y VISIBLE. PLACl:D ON 8 • l/2" X 11' SIZE;D SIGN. COLOR PURPLE; BACKGROUND WITH BLACK ll:TTtRING. GUIDE;LINES FOR RECYCLE;D WATtR USt IRRIGATE BtTWl.tN THE; HOURS OF 10:00 PM AND 6,00 AM ONLY. WATl:RING OUTSIDI. Tl-II: TIME; FRAM!: MUST Bt DONE; MANUALLY WITH QUALIFltD SUPE;RVISORY P(;RSONNtL ON-SITE. NO SYSTtM SHALL AT ANY TIMI. BE LEFT UNA TTtNDtD DURING USE OUTSIDI: Tl-It NORMAL SCHl:DULG. IRRIGATE; IN A MANNER THAT WILL MINIMIZE; RUN-OFF, POOLING, AND PONDING. THJ;; APPLICATION RA Tt SHALL NOT EXCEED Tl-II: INFILTRATION RATE: OF THI: SOIL. TIMERS MUST BE; ADJUSTED SO AS TO Bia COMPATIBLt WITH THE: LOWE.ST SOIL INFILTRATION RATE PRESENT. THIS PROCEDURE: MAY BE l=ACIUTATED BY THE: EFFICIE;NT SCHEDULING OF= THE AUTOMATIC CONTROL CLOCKS, (I.E. E;MPLOYING THE: RE;PE:AT FUNCTION TO BRE;AK UP THE TOTAL IRRIGATION TIME INTO CYCLES TI-IAT WILL PROMOTE MAXIMUM SOIL ABSORPTION. ADJUST SPRAY Hl:ADS TO ELIMINATE; OVE:RSPRAY ONTO ARI.AS NOT UNDl:R TH!; CONTROL OF THE; CUSTOMER. r:oR E:XAMPLE, POOL Dl:CKS, PRIV AT!; PATIOS AND LOTS AND STRl:tTS AND SIDEWALKS. MONITOR AND MAINTAIN Tl-IE SYSTtM TO MINIMIZE: EQUIPMtNT AND MATERIAL FAILURL Bl!OKE:N SPRINKLER I-IE;ADS, LEAKS, UNRE;UABLt VAL VtS, l:TC. SHOULD BE: RtPAIRtD AS SOON AS THl:Y Bl.COME APPARENT. E;DUCATt ALL MAINTE:NANCt PtRSONNtL ON A CONTINUOUS BASIS OF TH!a PRESENCE OF RECYCLED WATER. Pl:RSONNtL MUST BE INFORMED THAT RE;CYCLtD WATE;R IS M!aANT FOR IRRIGATION PURPOStS ONLY, AND IS NOT APPROVE;D FOR DRINKING PURPOSES, HAND WASHING, CLEANING OF TOOLS, ITC GIVtN Tl-IE: HIGH TURNOVER RAT!: OF tMPLOYE;I.S IN THI: LANDSCAPE INDUSTRY, IT IS IMPORTANT THIS INFORMATION BE DISStMINA TtD ON AN ALMOST DAILY BASIS. IT IS YOU, Tl-IE LANDSCAPI: CONTRACTOR WHO IS RE;SPONIBLt FOR E:DUCATING EACH AND !;VERY ONE OF YOUR 1:MPLOYtES, OBTAIN PRIOR APPROVAL OF ALL PROPOStD CHANGtS AND MODIFICATIONS TO ANY PRIYATt ON-SITE FACILITIES. SUCH CHANGtS MUST St SUBMITTE:D TO, AND APPROVE:D BY THE DISTRICT ENGINttRING JOFFICt AND DI.SIGNED IN ACCORDANCE WITH DISTRICT STANDARDS. ALL RI.CYCLED WATtR SPRINKLtR CONTROL VALVE:$ SHALL Bt TAGGtD WITH IDtNTIFICA TION TAGS. A. TAGS SHALL BE WleATl-ll:RPROOI= PLASTIC 3" X 4", PURPLt IN COLOR, WITH Tl-It WORDS "WARNING -RECYCLED WATE;R • DO NOT DRINK• IMPRINTE;D ON ONE; SIDE; AND• NO TOME EL AGUA" ON THE OTHE:R SIDI.. IMPRINTING SHALL Bl. PE;RMANE;NT AND BLACK IN COLOR. USt TAG AS MANUFACTURI.D BY T. Cf-lRISTY l:NTtRPRISE;S OR APPROVED 1:QUAL. B. ONI: TAG SHALL Bt A TT ACHE;D TO 1:ACH VALVE; AS FOLLOWS, 1. ATTACH TO VALVE STEM DIRE:CTL Y OR WITH PLASTIC Tll:-WRAP, OR 2. ATTACH TO SOLE;NOID WIRE DIRl:CTL Y OR WITf-1 PLASTIC TIE-WRAP, OR 3. ATTACH TO VALVE: COVE;R WITH tXISTING VAL Vt COVER BOLT. ALL SPRINKU,R 1-11:ADS SHALL Bt IDE;NTll=ll:D AS Rl:CYCLtD WATtR SPRIKLl:R HtADS. II. E;ACI-I AUTOMATIC CONTROLLl:R AND ITS ASSOCIATE;D E:QUIPME;NT SI-IALL BE IDE;NTIFIED WITH A SIGN Bl.ARING THI: WORDS "RtCYCLEaD WATI.R USJ;;D FOR IRRIGATION IN ENGLISH AND SPANISH, WITH BLACK LETTI.RS 1" HIGH ON A PURPLE; BACKGROUND. THI: SIGN SHALL BE: PLACl:D SO THAT IT CAN BE; Rl:ADILY Stl:N BY ANY OPl:RATIONS Pl:l!SONNtL UTILIZING THt 1:QUIPMl:NT. I HERE:BY DE:CLARt THAT 1AM THE LICtNStD DE;SIGNE;R OF WORKFOR THIS PROJl:CT, THAT I I-JAVE E:XE;RC!Sl:D RESPONSIBLE; CHARGt OVl:R Tl-IE: DESIGN OR THE; PROJtCT AS DEFINE:D IN SE;CTION 6703 01= THC BUSINESS AND PROFtSSIONS CODI:, AND THAT THE; Dl:SIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE; Cl-II.CK OF PROJtCT DRAWINGS AND SPtCIFICA TIOINS BY THI. CITY OF CARLSBAD IS CONFINED TO REVIE:W ONLY AND DOSI: NOT RtLIEVE; ME, AS THI: LISENSED DtSIGNE:R OF WORK, OF MY RE;SPONSIBILITIE;S FOR PROJECT DESIGN. THI.SI: PLANS HAVE BE;EN PRE;PARED IN SUBSTANTIAL CONFORMANCE WITH THI: APPROVtD LANDSCAPt CONCtPT PLAN, WATE:R CONStRVATION PLAN, FIRt PROTtCTION PLAN, AND All CONDITIONS o:~v ~ RELA TtD TO LANDSCAPING. BY: ~-...-~--DATI:, j, t;.OI',::, LARR SHtEHAN INSPECTION PROCEDURES CITY LANDSCAPE; INSPl:CTOR, {760) 815-6708 1. CITY CONSTRUCTION INSPtCTION SHALL INCLUDE;, A. LOCATION 01' PIPE LINtS B. TRI.NCH Dl:PTf-1S C. RI.QUIRED SE;PARATION (HORIZONTALLY AND Vl:RTICALL Y) D. PIPE: INDl:NTIFICATION E. POINTS-01=-CONNtCTION (POC'S) F. LOCATION AND IDJ;;NTIFICATION OJ: SPRINKLE;R HE;ADS G. WARNING SIGNS AT THJ;; SIT!. AND ON THE TRUCKS HAULING RECYCLtD .. WATE:R (IF RtCYCLtD WATtR IS UStD FOR CONSTRUCTION) ~ AN APPROVI.D LtTTtR RI.GARDING THI: INSPECTION OF THE PROJE;CT SHALL BE OBTAINED FROM Tl-IE CITY AND THt DISTRICT AND Bt l=ORWARDED TO THt SAN 0I1:GO COUNTY DI.PARTMENT OF ENYIROMEaNTAL HtA TH PRIOR TO J:INAL INSPE;CTION APPROVAL. 2. DISTRICT FINAL INSPE:CTION SHALL INCLUDfu A. COVE.RAG!. TEXT, Al=TER COMPLtTION OF THI: SPRINKLtR SYSTE;M, TO DI.TERMINI. Tl-II: ADtQUACY OF COVtRAGE ON THt APPROVtD USE: ARI.A RECYCLl:D WATER usi; ---~ ARtA(TYP) AND PROTE;CTION OF AREAS NOT APPROVE;D FOR RECEIVING RE;CVCLE;D WATE;R B. WARNING SIGNS AND LABLES C. QUICK COUPLING VALVES D. ALL ASPtCTS OF THE IRRIGATION CONDITIONS INCLUDING WINDBLOWN SPRAY, E;. R!.QUIRtD PROTECTION Of= ALL RtSIDtNTIAL ARI.AS I=. REQUIRE;D PROTECTION 01= WtLLS, STRl:AMS, Rl:SERVOIRS, ITC. G. CROSS-CONNE;CTION /BLACK LOG~ .,-----l" BLACK lE:TTl:llS (II, ~------,---------.r r l IN ORDER TO CONSE;RVE; WATtR 12" X 36" Sil!, 0.032 ALUMINUM, 0.060 ABS PLASTIC OR STICK-ON VINYL SIGNS WARNING R CYCLED WATER DO NOT DRINK RtCYCLE;:D WA TtR WASl--11--lANDS A!=TE;R CONTACTING LAVES!;: SUS MANOS DE;SPUE;:S DE; USAR ------l"BLACK LETTi;RS ~----PURPLEBACKGROUND RE;QUIRtD SIGNAGI: FOR RECYCLED WATER USE AREAS, ALL usi; AREAS ACCl:SSIBLE: TO Tf-1(; PUBLIC SHALL BE POSTED WITH SIGNS (MINIMUM 2 PER Ml:TE:R) THAT ARE; VISIBLE; TO THE PUBLIC Rt;:CYCLt;: WA Tt;:R SIGN RECYCLED WATER IN USE DO NOT NO TOMI. tl DRINK AQUA WASH HANDS AFTE;R CONTAINING LA vi;;si; SUS MANOS DESPUtS DI: USAR 16" X 18" S!Zli 0.032 ALUMINUM. 0.060 ABS PLASTIC OR STICK-ON VINYL SIGNS - - THE:RE; ARt NO WtLLS, FIR!: HYDRANTS, OR FIR!. LA TE;RALS ON THIS SITE. P.O.C. II 1 (RtCLAIMI.D WAT&R) NEW 1 'WATi;R ME"TER Ni;W 1 'BACKl'I.OW PAii VENTER NEW 1 • MASTER VAL VE NEW l "FLOW SENSOR DESIGN DEMAND• 38 GPM PSI •99.6 00 rJ IRRIGATION LEGEND ® RE:CYCLE:D WATtR Ml:Tl:A / CONNE:CTION EXISTING POTABLE; WATE:R Mt;TE:R LOCATION IRRIGATION CONTROLLE:R R(;CYCLl:D WATtR SIGN LOCATION 8"◄ l=IRI: HYDRANT AND LATtRAL LOCATION 1111111 I 1111111 Rl:CVCLE;O WATE:R MAINLINE: SAN DltGO COUNTY Department of Gviromenlol Health Land Use DivWon /-lkl7 CARLSBAD MUNICIPAL WATl;R DISTRICT APPIIOVlaOSV• /4ki/4,,,.,..r. ~>4' -,.,...,,-· DAT .. I-S -07 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. •• ...,-· ,-., CITYOI' tl,O~ SAN MARCOS INTE;:GRATION [;;iiiaiiiiii DEiSiGN STUDIO p L A 160clo6 N D A T E 1st Submittal R------+---+--------------t------ir------ir------ir------t IT] CITY PLA<l~G £tR~M~~ BAD ~ A E: V I s I 0 N s l----f-'--1-----------------+---+--+----+---I LANDSCAPE IRRIGATION TITLE SHEET: LANDSCAPE; ARCHITE;CTS 7Deco6 2nd Submittal LA COST A LOT 1.3 RV PARKING 5411 Avenida tncinas, Suite 270 19Deeo6 3rd Submittal Carlsbad, CA 920084'!8o 5Jan07 l=inal Submittal 26. TI-IERt SHALL BE A PHYSICAL Sl:PARATION BtTWI.EN ADJACI.NT ARI.AS IRRIGATED l---+-----4---------------·--+---l-----+----t---l I AP~t;lQVr,Q '=· 1-.11 :_, I'. I WITH RECYCLl:D WATI.R AND POTABLE WATl:R. SE;PARATION SHALL Bl. PROVIDtD 1'1...\-J <:--L· 1&-11~ \ l· 14 . .,-, BY CONCRfTt STRIPS, CHAIN LINK FENCES, OR OTHE:R ME:ANS AS APPROVE':D BY PLANNING DATE . THE; WATER DISTRICT AND D.EI-I. 1----1----+------------------t---;----i----;------i ~-------;::_-=.-=.-=.-=.-=.-=.-=.-=.-=.-=.-=.-=.-=.-=.-:::;---~~ t 760.602.0144 f 7 60.602.0388 wwwJNTEiGAATION-D~SIGN.com I OWN BY, I PROJECT NO. DRAWING NO. DATE INITIAL f-'D--'AT-'E--'-'1"'-NIT-'IA"'L-+-ccDA"-'T"-E -'-'INc.c.lTccc!Al~ CHKD BY,___ .-.., 27. CALL OUT ON THI: PLANS If: THI.RE; ARE OR ARE NOT DRINKING FOUNTAINS VICINITY MAP ENGINEER OF WOR REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY, " CUPOS-03 442-7l ', ... AND/OR Dl:SIGNA TED OUTDOOR EA TING ARE:AS ON THI: SITE Hrs ProjecL---············--·· os.oos ~------~ 1- '--------------------------------------------------------·-----------------------------------------------------------------------------------------' .J J~,,,,,-_/.,.;..---- ,/,.-~ 30' COVlaNANT FOR ACCESS ESMT;>"'<- PA 5 ' ... ·.'·: , .. --·· .•. 3 ELEVATION -r ' I / -------,-.....----- I I ' J, / / NOTES. • ALL STEEL SHALL BE PRIMED AND PAINTED PER SPECIFICATIONS, PAINT COLOR, BENJAMINE MOORE "OTTER BROWN' -SEMI GLOSS • ALL WELDS TO BE GROUND SMOOTH • FENCE CONTRACTOR SHALL SITE VERIFY EXACT SIZE OF GATE OPtNING PRIOR TO FABRICATION • CONTRACTOR SHALL PROVIDE SHOP DRAWINGS. • CONTRACTOR TO COORDINATE OPENER PA PA 24' ' LEGEND OJ CONCRETE CURB AND GUTTEA PER CIVIL ENGINEERS PLANS II] CORRUGATED METAL GATE-PANEL -CONTRACTOR TO PROVIDE SAMPLE TO OWNtR PRIOR TO FABRICATION. Ill FINISH GRADE WHERE OCCURS -SEE PLANS (II 2 X 6 TUBULAR STEEL FRAME I GJ STUCCO PILASTER W / BRICK CAP -SEE DETAIL B III SCRtE:N WALL w / BRICK CAP • SEE DH AIL B [II ½ X ½ SOLID STEEL TRIM PIECE 0 GA TE: ROI.LtR • BY CONTRACTOR SOLi D MET AL GA TE TVPEANDLOCATIONSW/OWNER. ---------------/A\A GAT-MTL ~ i,.~OSCA.Pc !":? _, OF C~\.I 1o 7 7 7 2 ',,· .-. ,' . . 3 3 . ', ~· ELEVATION/SECTION LEGEND OJ PILASTER WITH SLURRY FINISH II] STUCCO -COLOR • EXPO• 2841 DC W/BRUSHED FINISH Ill 6' SLUMP BLOCK W / STUCCO FINISH GJ COMPACTED SUBGRADE. PER STRUCT. SOILS REPORT III CONCRETE FOOTING-PtR STRUCT. ENGINEER 0 FINISH GRADE [II BRICK CAP A BLEND OF 50'll, CUSHWA 'GEORGIAN' AND 50% CUSHWA 'ROCKDALE RED' NOTES, • VERT. & 1-lORIZ REBAR -PtR STRUCT. tNGINEER 8_WA:--5~_1G_H_S_T_LJ_C_C_Q_W_A_L_L ___ ® INTEGRATION p L A N D A T E i:.iiil riiiiiiiii liiil 160ct06 ut Submittal DESIGN STUDIO R i;: V I s I 0 N s LANDSCAPE ARCHITECTS 7Deeo6 2nd Submittal 5411 Avenida rneinos, Suite 270 19 Dec06 ard Submfttal C..rlsbad, CA 92008.4380 10Jano7 Final Submittal t 760.602.0144 f 760.602.0388 -.INTEGDATIQN.DESIGN- DATE INITIAL - - -. --------- DATE CONSTRUCTION LEGEND SYMBOL Cl CP EQ PA POB PT R rv 7 DlaSCRlPTION CENTERLINE CENTER POINT EQUAL PLANTING ARfA POINT OF BEGINNING POINT OF TANGfNCV RADIUS ALIGN WITH ADJACENT SURFACE ALIGN PERPENDICULAR fXPANSION JOINT EXPANSION JOINT W/ SEALANT SCORE JOINT NOTE, ALL DIMENSIONS TO WALLS ARE FROM FACE OF WALL UNLESS OTHERWISE NOTfD. NOTES SYMBOL DESCRIPTION s· HIGH SOLID SLIDING GATE -SEE DH AIL A/THIS SHEET PILASTER-SfE DETAIL -A/ THIS SHEET s• HIGH FREE; STANDING SCREEN WALL -A/ THIS SHEET PLANTABLE RETAINING WALL SEE RETAINING WALL PLANS BY SOIL RETENTION PARKING LOT STRIPING-BY OTHERS SEE THIS SHEET !=OR CONSTRUCTION DETAILS SEE SHEET 4 l=OR CONSTRUCTION SPECll=ICATIONS CUPOS-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ~ I SH~ET I CITY OF CARLSBAD PLANNING DEPARTMENT 4 LANDSCAPE CONSTRUCT/ON PLAN AND DFTAl{S: -... ---LA COSTA LOT 1.3 RV PARKING ----------- --·--.. ----· - -.. -------"' I APrf!f.:°( Gt"• ... ._. -·----· l-l'1-~D;T[ I ~~ :PLANNING ----- DWN BY, PROJECT NO. DRAWING NO. INITIAL DATE INITIAL CHKD BY: CUPOS-03 442-7L REVISION DESCRIPTION RVWD BY, ENGINEER OF WORI OTHER APPROVAL CITY APPROVAL ~---~------------·~· --~ ---0 10 20 40 North Arrow . -----------------------------------------' Z:\2005 P R O J E C T s\O:i.008 Lo Co1>to RV\Drowing Files\C0's\Canstdwg\LC-1\9 JQll 2007 8;46 AM by: Slotkm3 ..... I . U! ...J: \ l LANDSCAPE; CONSTRUCTION SPE;:Cll=ICATIONS l. SCOPE;, PROVIDE LABOR, MATERIALS, PERMITS, EQUIPMENT, SUPERVISION, SERVICES, TRANSPORTATION AND ALL OTI-IER ITEMS NECESSARY TO COMPLETE ALL CONSTRUCTION WORK AS INDICATED AND SPECll=IED WITI-HN TI-IESE PLANS BY INTEGRATION DESIGN STUDIO. Tl-IE INSTALLATION SHALL BE COMPLETE IN EVERY RESPECTTOTHESATISl=ACTION 01= THE OWNER .. 2. GE;N!:;:RAL, A. GENERAL CONDITIONS l. IT IS TH£ INTE:NT THAT ALL IMPROVE:ME:NTS SHALL BE CONSTRUCTE:D, ASSEMBLED AND INSTALLED IN AN El=FICIENT AND SATISFACTORY MANNER ACCORDING TO THE I-IIGI-IEST WORKMANLIKE STANDARDS. IMPROVEMENTS SHALL BE COMPLETE IN EVERY RESPECT AND SI-IALL BE LEl=T READY FOR THEIR INTENDED USE AND/OR OPERATION BY Tl-IE OWNER. 2. THE CONTRACTOR SHALL CARRY ALL NECESSARY COMPENSATION, LIABILITY AND PROPERTY DAMAGE INSURANCE TO COVER HIS WORKERS AND INSTALLATION SO AS TO OFFER FULL PROTECTION TO THE OWNER FROM ANY POSSIBLE DAMAGE SUIT OR LIEN ON THE OWNER'S PROPERTY. 3. THE CONTRACTOR SHALL APPLY AND PAY FOR NECESSARY PERMITS AND FEES REQUIRED BY LOCAL GOVE;RNING CODE;S AND MUNICIPALITIE;S TO COMPLE;TE Tl-IE WORK. 4. THE; CONTRACTOR SHALL BE; RESPONSIBLE FOR ANY ENCROACHMENT ONTO ADJACENT PROPERTY, RIGHT-OF-WAYS, EASEMENTS, SET-BACKS OR ANY OTHER LEGAL PROPERTY RESTRICTIONS EITHER MARKED OR UNMARKED. 5. LOCAL MUNICIPAL AND ST A TE CODES, LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY MADE A PART OF THESE PLANS AND SPECIFICATIONS. 6. THESE PLANS ARE PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL VE;RIFY ALL SITE CONDITIONS AND DIMENSIONS SHOWN ON THE PLANS AFFECTING THE INTENDED DESIGN OF THE CONSTRUCTION WORK. ANY DISCREPANCIE;S S1-lALL BE REPORTE;D TO Tl-lE OWNERS REPRESENTATIVE IMMEDIATELY. 7. ANY DISCREPANCIES BETWEEN THE SITE CONDITIONS AND THE CONTRACT DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL COMPLETION AND COST OF Tl-lE PROJECT SHALL BE REPORTED TO THE OWNER'S RE;PRESENTATIVE AND LANDSCAPE ARCI-IITECT IMMEDIATELY. ANY CONTINUATION OF WORK PRIOR TO THE RESOLUTION OF DISCREPANCIES IS AT THE CONTRACTOR'S RISK AND EXPENSE. 8. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF CONSTRUCTION ELEMENTS WITH TO AVOID CONFLICTS WITH GRADING, PLANTING, IRRIGATION, UTILITIES, OR ENGINEJ;:RING OR ARCI-IITECTURAL FEATURE;S TI-IOUGI-I THE OWNE;R'S REPRESENTATIVE. 9. PRIOR TO INSTALLATION, THE CONTRACTOR SHALL LOCATE BY ST AKES, OR OTHER MEANS, ALL CONSTRUCTION ELEMENTS AS DELINEATED ON THE PLANS FOR APPROVAL BY THE OWNER'S REPRESENTATIVE AND LANDSCAPE ARCl-llTECT. 10. TI-IJ;: CONTRACTOR SI-IALL BE LIABLE FOR DAMAGE TO ALL UTILITIES, CONSTRUCTION, IRRIGATION AND PLANTING ELEMENTS, EXISTING OR NEW, MARKED OR UNMARKED, AND SHALL RE PAIR OR REPLACE ANY DAMAGED IMPROVEMENTS IN A MANNER ACCEPTABLE TO THE OWNER'S RE;PRESENTATIVE. 11. CONSTRUCTION SUB BASE REQUIREME;NTS, COMPRESSIVE STRENGTI-I, SLAB TI-IICKNESS, CONTROL JOINTS, REINFORCEMENT, ETC. OF ALL PAVING ON GRADE SI-IALL BE IN ACCORDANCE WITI-I Tl-IE RECOMMENDATIONS OF Tl-lE PROJECT GEOTECI-INICAL ENGINEER AND/OR PROJE:CT STRUCTURAL ENGINEER. 12. ALL CONSTRUCTION AND WORKMANSI-IIP SHALL CONFORM TO THE CURRENT EDITION OF THE UNll=ORM BUILDING CODE. B. PLANS 1. ALL CONSTRICTION ITEMS SHALL BE LOCATED AS DIMENSIONED ON THE PLANS UNLESS OTHERWISE INDICATED IN NOTES, DETAILS, LEGENDS AND AND SPECIFICATIONS. 2. DIMENSIONS ARE TAKEN FROM FACE OF VERTICAL IMPROVEMENTS UNLESS NOTED ON PLANS. 3. IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS OR DETAILS ON THE DRAWINGS ON Tl-IE DRAWINGS. 4. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL B!,'.; THE SAME: AS OTHER SIMILAR WORK SHOWN OR NOTED ON Tl-IE PLANS. 3. WALLS, A. GENERAL, 1. ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO Tl-IE CURRENT EDITION OF THE UNIFORM BUILDING CODE. 2. ALL MASONRY BLOCK COURSE FOR RETAINING AND FREESTANDING WALLS SHALL BE SET LEVEL, CONTRACTOR SHALL RESOLVE ALL DISCREPANCIES PRIOR TO COMMENCEMENT OR WORK. 3. ALL MASONRY BLOCK SHALL BE REINFORCED GROUTED SOLID MASONRY UNLESS NOTED OTHERWISE. GROUT SOLID ALL CELLS WHICH CONTAIN REBAR, BOLTS, ETC. IN MASONRY SHALL HA VE A MINIMUM GROUT COVERAGE 01= ¾". 4. CONTRACTOR SHALL BE RESPONSIBLE FOR BACKFILLING ALL WALLS TO GRADES PER PLAN, FINISH GRADING FOR RUNOFF SWALE BEI-IIND ALL WALLS, PERFORATED DRAIN LINES COMPLETE, WATERPROOFING All WALLS BELOW GRADE AND ALL EXCAVATION NECESSARY FORTI-IE EXECUTION OF MASONRY WORK. RELATIVELY NON-EXPANSIVE FILL SHALL BE ADEQUATELY SHORED DURING THE BACKFILL OPERATION. 5. WALL FOOTING SIZE, SHAPE, REINFORCEMENT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS. 6. TOP OF WALLS SHALL BE CONSTRUCTED LEVEL UNLE;SS OTEl-lRWISE INDICATED ON PLANS. 7. WALLS SHALL BE INSTALLED PRIOR TO WALK INSTALLATIONS. B. PLASTER: 1. ALL PLASTER FINISHES, TEXTURES AND COLORS SHALL MATCI-I REFERENCED ARCHITECTURE UNLESS OTHERWISE NOTED ON PLANS OR AS DIRECTED BY OWNER'S REPRESENTATIVE. APPLY A SAMPLE AREA l=INISH PLASTER COAT OF 4'X4' FOR OWNER APPROVAL PRIOR TO PROCEEDING WITH BALANCE OF PLASTER WORK. 2. APPLY A NON-YELLOWING WATER SEALER TO ALL PLASTER SURFACES AS APPROVED BY THE OWNER'S REPRESENTATIVE. C. MORT AR JOINTS, 1. ALL MORTAR JOINTS SI-IALL BE PORTLAND CEMENT --LIME MORTAR TYPE "S' AND CONFORM TO THE LA TEST ASTM STANDINGS. 2. All VISIBLE JOINTS SHALL NOT EXCEED½". D. BRICK CAPS: 1. MORTAR SHALL BE ACCEPTED AS SPECIFIED ABOVE. 2. SUBMITT ALS: a. BECAUSE BRICK COLORS AND l=INISI-IES MAY BE ALTER!,'.;D BY MANY FACTORS, THE CONTRACTOR SHALL PREPARE ONE (I) SET OF BRICK SAMPLES FOR REVIEW AND APPROVAL BY Tl-IE OWNER. SAMPLES SHALL BE PREPARED FOR EACH TYPE OF BRICK SPECIFIE:D ON THE PLANS AND FOR EACH PATTERN IDENTIFIED ON THESE PLANS. THE SAMPLES SI-IALL BE 2'X2' SQUARE. THE SAMPLES SI-IALL BE PRE;PARED USING THE EXACT CONTEMPLATED MATERIALS AND CONSTRUCTION TECI-INIQUES INCLUDING GROUT COLORS, SEALE;RS, JOINT FILLER, ETC. SAMPLES SHALL BE PREPARED AT A LOCATION DESIGNATED BY OWNER;S REPRESENTATIVE. APPROVED SAMPLES SHALL BE LEFT IN PLACE II= APPROVED BY THE OWNER'S REPRESENTATIVE. CONTRACTOR SHALL PROTECT SAMPLES !=ROM DAMAGE OR LOSS. APPROVED FINAL SAMPLE WILL BE THE STANDARD FOR BRICK WORK. 7. INSTALLATION: A. Gt;:NERAL: 1. TOP OF WALL SHALL BE FREE FROM DEFECTS, AND SI-IALL CONFORM TO Tl-IE SHAPES, DIMENSIONS AND FINISH GRADE ELEVATIONS AS INDICATED ON THE PLANS. b. MORTAR JOINTS a. ALL MORT AR JOINTS SHALL BE PORTLAND CEMENT--LIME MORTAR TYPE'S' AND CONl=ORM TO THt LATEST ASTM STANDARD. b. ALL VISIBLE JOINTS SHALL NOT EXCEED½". c. CURING AND SEALING, 1. SEAL BRICK SURFACES WITH AN APPROVtD SEALER d. FIELD QUALITY CONTROL: 1. INSPECTION, REQUtST REVIEW BY OWNER'S REPRESENTATIVE;: 01= EACH OF THE l=OLLOWING ITEMS PRIOR TO CONTINUING WITI-I THE WORK, • WALL LAYOUT • • SUB-GRADE PREPARATION AND REINFORCING STEEL INSTALLATION. • SUBBASE • INSTALLATION OF BRICK i. ADJUSTING I 1. REMOVE BRICK PAVING WHICH IS DAMAGED, NOT TRUE TO LINE AND PLANE, AND NOT PROPERLY FINISHED. SUCH WORK SHALL BE REMOVED AND REPLACED TO THE REQUIREMENTS OF TI-IIS SECTION. INTl::GRATION p LAN DATE [;. liiiiiiiiiiiii liiil 16 Oct 06 l.t Submittal Or::SIGN STUDIO LANDSCAPE ARCHITECTS 5411 Awnida E.ncino$, Suite 270 Carlsbad, CA 9,ooa.4380 t 760.602.0144 I 7,!0.602.0388 -.1 NTEGRATION-D!;SIGN.-. REVISIONS 5. METALS: A. GENERAL: 1. ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO Tl-IE CURRENT EDITION OF THE UNIFORM BUILDING CODE. 2. METAL WORK SHALL BE FREE OF DEFECTS WHICH IMPAIR STRENGTH, DURABILITY AND APPEARANCE. 3. PROTECT ALL DISSIMILAR METALS FROM GALVANIC CORROSION BY PRESSURE T APl::S, COATINGS OR ISOLA TORS. B. STl::El AND IRON, 1. ALL WE .DS SHALL BE CONTINUOUS AND FREE FROM IRREGULARITIES. ALL EXPOSE:> CUTS AND WELDS SHALL BE GROUND SMOOTH. 2. REMOV[ ALL SPLATTER AND SLAG. 3. ALL BOLTS TO BE GRADE 5 OR BETTER AND BE COATED WITH A NON- RUSTINn MATERIAL C. DECORATIVE ALU AINUM, 1. ALUMIN JM Sl-lALL I-IAVE A MINIMUM THICKNESS OF½" TI-IICK. 2. All EX~ OSED ALUMINUM SURFACES SHALL BE THOROUGHLY CLEANED AND PRIMED THI:: APPROVE;D PRIMER SHALL HAVE A DRY FILM THICKNESS OF .5 MIL OR GRATER. ALL EXPOSED ALUMINUM SURl=ACE;S SHALL RECE;IVI:: A BAKED-ON ENAMEL FINISH, WITH A DRY FILM OF TI-IICKNESS OF .7 Mil OR GREATER. THE FINISl-l COLOR SHALL BE AS INDICATED ON PLANS. D. ORNAMl::NTAL IRON Fl::NCES, 1. ALL FENCING AS SHOWN ON THE PLANS AND DE:T AILS IS INTENDED TO MEET THE MINIMUM STATE AND LOCAL CODES. ALL CONDITIONS THAT 00 NOT CONFORM SHALL BE BROUGHT TO Tl-IE OWNER REPRESl::NTATIVE'S AND LANDSCAPE ARCl-llTECT'S ATTENTION PRIOR TO FABRICATION AND INSTALLATION. 2. ALL TUBULAR STEEL FENCE MEMBERS TO BE GAUGE 13 UNLESS OTl-lERWISE NOTED ON PLANS OR DETAILS. 3. CAP All EXPOSED E;NDS OF TUBULAR STEE;L WITH A M!,'.;TAL CAP. 4. ORNAMENTAL IRON FENCi::, POSTS, HARDWARE AND ACCl::SSORIES SHALL BE HOT DIP GAL VANIZE:D Al=TER FABRICATION IN COMPLIANCE WITH ASTM SPECIFICATIONS AS APPLICABLE. 5. ALL GALVANIZING SLAG SHALL BE RJ;:MOVED FROM METAL SURFACES PRIOR TO APPLICATION OF ANY FINISH COATING. ALL METAL SURFACE:$ INCLUDING ORNAMENTAL FENCE. POSTS. HARDWARE. AND ACCESSORIES SHALL BE CLEANED WITH 'OAKITE' #74L TS THERE;-ST AGE SPRAY PRODUCT OR EQUAL IN STRICT ACCORDANCE WITH FACTORY PROCEDURES AND MANUFACTURE'S INSTRUCTIONS. 6. WHERE FENCING IS LOCATED ON A SLOPE, RUN ALL HORIZONTAL RAILS PARALLEL WITH THE ADJACENT SURFACE OR GRADE: UNLESS OTHERWISE NOTED ON PLANS OR DETAILS. 7. ERECT PLUB, STRAIGHT, TRUE AND ACCURATELY FIX IN PLACE, BRACE, REINFORCE, AND ANCHOR IN PLACE. REMOVE SPLA TIER AND GRIND ALL FIELD WELDS SMOOTI-I. 8. AFTER ERECTION, CLEAN OFF All RUST, SCALE AND OIL CLEAN FIELD WELDS, BOLTS AND ABRADt;:D AREAS. SPOT PRIME ALL WELDS WITH 'TNEMEC' ZINC PRIMER #90-97, LEAVING ALL SURFACES READY TO RECEIVE FINISl-l COATS. 9. APPLY INTERMEDIATE COAT 01= 'TNEMEC HI BUILD EPOXOLINE II' #N69 TO ALL GALVANIZED AND SPOT PRIMED MET AL SURFACES READY TO ACI-IIEVE 3.0-5.0 DRY FIL A THICKNESS. APPLY PER MANUl=ACTURER'S INSTRUCTIONS. COLOR TO BE C FFliiRENT THAN FINAL FINISH COAT. 10. APPLY F INAL OF 'TN!,'.;MEC EN DURA-SHIELD POLYURETHANE' WITl-l 'TNEMEC U.V. BLCCKER #44-600 TO ALL EXPOSED METAL SURFACES TO ACHIEVE 3.0- 4.0 DRY l=ILM THICKNESS. APPLY PER MANUl=ACTURER'S INSTRUCTIONS. FOR LOW SI-;EN USE 'TNEMEC ENDURA-SHIELD' #]75, FOR GLOSS USE 'TNEMEC ENDURJ-SHIELD 11' #1074, OR FOR SEMI-GLOSS l=INISH USE 'TNEMEC ENDURA SHIELD I' 1075. SEE PLANS FOR COLOR AND FINISH. 10. GUARANTEE A. GUARANTEE: 1. ALL CONSTRUCTION WORK SI-IALL BJ;: GUARANTEED AGAINST ALL DEFECTS OF WORKMANSHIP AND MATERIALS, INCLUDING SETTLING OF GRADED AREAS, FOR A PERIOD OF ONE YEAR FROM Tl-IE DATE OF FINAL ACCEPTANCE (COMPLETION) BY OWNER. THE CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE ON HIS LETTERI-IEAD AT THE TIME OF THJ;: FINAL INSPECTION. CUP05-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ~===~~==~======================-__ -____ +_--+---1---1---~I I CITY OF CARLSBAD]~ LANDSCAPE CONSTRUCTION SPECIFICATION$: LA COSTA LOT 1.3 RV PARKING APPRO.'t:£D/ y _11 -H n..-,{. t tr--.::.-i,-<i u 1-----+--+----------------,----+---+--+--------1 ASSISTANT PLANNING -;:_:Dl=RE=CT=O=R ======::::...::::-:_::;·----~DA~TE~ 1-----+--+--------------·-·--·-·-~ · --------"""·"··"-+---+----1 DWN BY: _______ _ DATE INITIAL DATE INITIAL DATE INITIAL CHKO BY; __ _ PROJECT NO. DRAWING NO. REVIS! )N DESCRIPTION Project. ... HDMN•-•M• .. ··••« ... ,_ 05.008 ENGINEER Of WOR OTHER APPROVAL CITY APPROVAL RVWO BY: CUP05-05 442-?L N • u L.....----------------------------------------------------------;:Z:\~200;;;5:-;P;-;R;-;O:-;J-;:E-;:-C7T-;;;-S\;;;o,-;;;_co;;-87::Lo-;:-C,::;,to:-;R;:;:'/\-::::D,=:-:,:-:: •• -:::rn=-.... ,:-;;co::-.,,\:-;;SP::;;EC:::-S.d;-wg7:\C:;:ON:::::ST_-::.,,:::::,c:::::S\-::-,7J,-.,:-:::oo::-,-::c •• ,::-.-::-AM:-,-b-,.-:csto7,"...;"'==========-------------------------------------_,J _J IRRIGATION CONTROLLER 'A' NOTE: CONTROLLER Sl-lALL BE A RAINMASTER DX2 EVOLUTION MODEL #DX-12-SPED,DX-03,DX-RADIO-KIT,EV-ANT-FD-KIT 12, STATION CONTROLLER INSTALLED IN STAINLESS STE;E;L E;NCLOSURE-W/ SENSOR CABLE E;V-CAB-SEN {AVAIL. Tl-lRU: 1-lYDROSCAPE; PRODUCTS). FINAL LOCATION OF CONTROLLER AND ELECTRICAL POC SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. ! I ' NOTES: VAL VE ST A TION A-8 I RRIGA TE:S THE PLANT ABLE WALL SEE DE;TAIL G SHEET 8. .,-"' ', _ __,~/-~ ,.,.//,.,.-Oo+j1\ I 20' WIDE SEWE~ ESMT - -'s \ - \ l,-\4. II / / -- .._~SCAP,!:' ~ 1, -' ~~~~ -< 0 10 20 40 North Arrow INTEGRATION p L A N D A T E !:.ii iiiiiiiiiii 160ct06 ut Submittal DE:SIGN STUDIO R E V I s I 0 N s LANDSCAPE ARCHITECTS 7 Dec06 2nd Submittal 5411 Avenido Encinas, Suite 270 19 Deco6 3rd Submittal Carl.bad, CA 92008.4380 10Jano7 t=inal Submittal l 760.602.01.U f 760.602.0388 www,INTE:GRATION-DESIGN.- 05.008 DATE INITIAL NOTE;S, l. IRRIGATION HE:ADS WITHIN THE RIGHT-OF-WAY AND WHE:R!;:VE:R THEY ARE WITH IN 10' OF ANY HARDSCAPE TURF OR OTHE:R ARE:A WHE:RE PE:DE;STRIAN TRAFFIC MAY OCCUR SHALL BE: INSTALLE:D AS POP-UP HEADS SEE DETAIL F SHEE:T-8 ALL OTHE:RS TO BE INSTALLED ON RISER PER DETAIL H SHE:ET 8. 2. CHECK VALVES SHALL BE PROVIDED AS REQUIRED TO PREVENT LOW HE:AD DRAINAGE SEE SPE:CIFICA TIONS FOR TYPE. SEE SHEET 6 FOR IRRIGATION LEGE:NDS & CALC'S SEE SHE:ETS 7 THRU 8 FOR IRRIGATION DETAILS SEE SHEETS 9 THRU: 10 FOR IRRIGATION SPECll=ICA TIONS ---- ------ - DATE INITIAL ENGINEER OF WOR> REVISION DESCRIPTION OTHER APPROVAL DATE INITIAL CITY APPROVAL CUP05-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA, I SH~ET I CITY OF CARLSBAD I SH1E!TS-1 PLANNING DEPARTMENT ----------- LANDS CAP[ /RR/GA TJON PLANS: LA COST A LOT 1.3 RV PARKING ---". ----IAPP~ I -t -l-!9'-o:r I ___J1 -_{;r_:__~-ot PLANNING DATE DWN BY: PROJECT NO. DRAWING NO. CHKD BY: CUP05-03 442-7L RVWD BY: L------------------------------------------------------------------------------z::-:,\-:2-:::007,-:P-:R-:O:-,-J-:::E-::C--:T--:S\::-o-::,-::_oo-::,-:t.o---:c,-,-:"-::""'-=orn-m7·,-,-::,.::-1les7\'.'.:co-:,,\-:,R:::R::::,o-:,,-,\::-L-:,_-::,\-::9-:J,-n-:,-:::oo:::,-:,-:::,,::oo:-".p::'.M-:,-,,-;c::-,,n------------------------------------------------------------~ i ,...., ...!. i .J: ..... c:, Q. ::;: 0: u, ~ ffi ..... ..... .,--- ..... RAIN BIRD PRESSURE COMPENSATING SCREEN CHART M0DE:L PCS.010 PCS-020 PCS-030 PCS.040 PCS.060 GPM OJ 0.2 0.3 0.4 0.6 COLOR PURPLE BROWN SILV.:R ORANGE BLACK =• 5' 5T 5' 51-l 4' 5' SF 5' a,., 4' 8' BT 6' 7' 8' 8H 5' 7' 8' 8F ... ~· 8' 1Qr"1 'Z 6' I!: 10' JOT 4' 9' 10' lOH 3' 6' 8' 10' 11"11= 1' 4' .,.., s s· 11' 12' 12T 'Z 6" 10' 11' 12H 4' 6' 10' 12TT 'Z 4' 6' 12TCJ 'Z 3' 6' 12F 2' S' •~-• ~-5' ., 17 151 5' 7' 12' 15H s 4' 7' 15TT l' 2' 4' 15Tu 151= 1ocr, •~s, .. -.. ,,v ,, ... y ,., , .. ., A'YS' 4'X10' ,rr>T 4'X 12" ,If y • ..,., ~-•-B z 4' 5' 5H-B 1' 'Z 5' 5F-B I' 2' 5CST-B 1' ,. 5' 1""1-SLA 1' 'Z 8' 11' 16' 16H-SLA 0.5' 1' 4' 9' 161'-SLA ~r, 2' 22"-SS 'Z 7' 12' 20' 22H-SS z 4' 8' 22F-SS 2' PCS.090 PCS-125 0.9 125 WHITE: GREl::N 8' 10' l'Z l'Z 9' l'Z 8' 10' 7' 8' 15' 14' 11' 8' 13' A' 14' ,, 10' 4"X4' -7"X.7' 9'X9' v'X 11 -;i, X 15' 14')( 11 4' X 15' 4 X16' 3' 5' l'Z 16' 3' 6' 22 14' 2'l 5' P.0.C. • IRRIGATION Lt Gt ND FRICTION LOSS CALCULATIONS CUPOS-03 NON-POT ABLE. IRRIGATION NOTE;S 1. ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF Tl-llS WORK ARE 1-l!;REBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY Tl-lE CONTRACTOR. SYMBOL MANUFACTURER/MODEL DESCRIPTION PSI GPM PRECIP. RADIUS DETAIL WATER ME:TE:R NO. I SIZE: 1' Q H F SST EST ELEVATION 320. STA TIC PRESS. HIGH 99.6 PSI LOW . --PSI 00 M $ INFO. S0URC& CMWD I@ lg • PHONE, 760602-2720 DATE: OF INFO. 29NOV06 I@ li:il -ill H.G.L. 550 METER ELEV. 320 [!I ~ ■ 230 X .4J3• 99.6 G B Hl REMOTE: CONTROL VALVE No. A-3 SIZE •1 QTR. HALF FULL RAINBIRD 1812-PRS-5 30 0.10 0.20 0.41 RAINBIRD 1812-PRS-8 30 0.26 0.52 1.05 RAINBIRD 1812-PRS-10 30 OM 0.79 1.57 RAIN BIRD 1812.PRS-12 30 0.65 1.30 2.60 RAINBIRD 1812-PRS-15 30 0.92 1.85 3.70 ADJ. SST EST RATE; .. 1.83 VAR. •• 237 VAR ... 1.75 VAR. •• 2.01 VAR. -1.83 5' 8' 10' 12' 15' 2. F&H/8 F& H/8 F&H/8 F&H/8 3. F&H/8 4. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMME:NCING WORK. THE; LOCATIONS OF UTILITIE.S, STRUCTURES AND StRVICES SHOWN IN THESE: PLANS ARE APPROXIMATE: ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNE!l'S REPRESENTATIVE. C0NTRACTORSl-lALL VE:RIFY PROPOSED LOCATION FOR BASKET STAINER AND IRRIGATION CONTROLLER PAIOR TO INSTALLATION. THE CONTRACTOR Sl-lALL OBTAIN ALL NECESSARY PERMITS RGQUIRED TO PERFORM THE WORK INDICATED HEREIN BE!'0RE BEGINNING WORK. THE CONTRACTOR SHALL OBTAIN Tl-lE PtRTINENT ENGINE:ERING OR ARCl-llTECTUAL PLANS BEFORE BEGINNING WORK. MAX.DEMAND 30 GPM 4' ~ ELEV. OF HIGHEST HEAD 320 RAINBIRD 1812-PRS-15-STRIP 30 0.40 0.30 2'x10'/3',l2' F & H / 8 CONTRACTOR SHALL COORDINATE ALL IRRIGATION LINES AND CONTROLLER WIRES WITH PROPOSED LOCATIONS OF PLANT MA TE RIAL AND ROOT BARRIERS PRIOR TO INSTALLATION. ALL PRESS. AT RCV 99.6 PSI QTY. SIZE: 1" WATER METrn 1' PRESS. RE:GULATOR (FALL OFF) BASKET STAINER FLOW METER MASTE:R VALVE: GATE VALVE 350' 11/2' MAINLINE 1 1' 53' 3/4" 10' 1' 10' 1' MAINLINE MAINLINE MAINLINE MAINLINE CONTROL VAL VE LATERAL LINE LATERAL LINE LATERAL LINE: LATERAL LINE LATERAL LINE LATERAL LINE FITTING LOSS 00%) ELEVATION CHANGE(•/-) TOTAL SYSTEM LOSS, PRESSURE TO OPERATE HEAD TOTAL PRESSURE: REQUIRED, LOWEST ST A TIC PR(SSURE AVAILABLE PRE-SET BOOST PUMP PRESSURE (IF REQ'D) RESIDUAL WATER PRESSURE REQ'D RE'SIDUAL WATER PRE'SSURE PCS-175 PCS-260 PCS-370 1.75 2.60 3.70 Yl::LLOW SLUE RED 12' 12· 13' 15' 14' 15' 10' 12' n'X" 10' X 15' in' X 16 yY , x,4 4•Y~ 12' 16' 18' Tl 5.3 11.0 8.00 X X X X 5.6 .50 .30 .10 3.0 0 33.8 30.00 63.8 99.6 35.6 PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI PSI P.0.C. [I] FEBC0 NO SYMBOL HUNTER & RAIN MASTER (I) NIBC0 lil DATA INDUSTRIAL () NELSON ® GRISWOLD s HUNTER AS APPROVED _I_!_ AS APPROVED -ASAPPR0VED 15-20 PSI NO SYMBOL AS APPROVED NO SYMBOL SP£ARS V RAINBIRD N0SYMBOL K.B.I. NO SYMBOL K.8.1. RE.CLAIME;D WATE;R TAGS/ TAPE; 0 WARNING TAPE WARNING LABEL 'T. CHRISTY' ID-MAX-PX-RC-009 N0N-POTABL!; WARNING TAGIN BOTl-l ENGLISl-l AND SPANISH. USEIN ALL VALVE BOXES AND BELOW GRADs. 'T. CHRISTY' 3' ND PRW NON-D!;TECTABLE PURPL!; TAPE LABE:LED"CAUTION. RECLAIMeD WATER BeL0W" LOCATE ABOVE ALL MAINLINE 'T. CHRISTY" •4100 CONTROLLER UNIT LABEL· 3.5 Mil VINYL BASE (PURPLE)· ATTACH TO FACE OF CONTROLLER ENCL. INTEGRATION C.iiiiiiiiiiil DESIGN STUDIO LANDSCAPE ARCHITECTS 5411 Avenida Encinas. Suae 270 Carlsbad, CA 920084380 t 760.602.0144 f 760.602.()388 www.lNTliGRATION-DESIGN.t0tn Project. ....... ,-~ ........ ~ ...... ~---05.008 1' RECLAIMeD WATeR METER WITH 2" SE:RVICE LINE-CONTRACTOR SHALL COORDINATE N/A AND PAY ALL ASSOCIATeD FE.S/COSTS FOR THE; INSTALLATION OF A NEW 1" RECYCLED WATER METER AT THE EXISTING 2 ' RECYCLED WATER SERVICE LINE. VERIFY SIZE, LOCATION, AND STATIC WATER PRESSURE IN FIELD 825 A SeRIES, 1 ' R/P BACK FLOW PRl::YENTI0N ASSEMBLY W / WYE STRAINER D / 7 MINI-CLIK AUTOMATIC RAIN SHUTOFF DeVICE MOUNTED TO THE ENCLOSURE EVOLUTION DX2 CONTROLLER IN A STRONGBOX STAINLESS STEEL TOP MOUNT ENCLOSURE· (REFER TO C0NTR0LLl::R NOTE FOR MODEL NUMBER) TFP-600 FULL PORT BALL VALVE· 2" & SMALLER (LOCATE IN PLANTER AREAS· SHOWN FOR CLARITY ONLY) 2508 SeRIES FLOW S!;NS0R, INST ALL PER MANUFACTUREll'S REC0MME TDATI0NS AND WIRE: TO CONTROLLER (SIZE AS SHOWN ON PLAN) 7645 1" QUICK-COUPLER VAL VE · INSTALL 6' FROM HARDSCAPE OR HEA ·ER BOARD 2000E SERIES EPOXY COATED MASTER REMOTE CONTROL VALVE (SIZI-AS SHOWN ON PLAN) !CV SERIES PLASTIC EleCTRIC REMOTE CONTROL VALVE WITH ACCU-51 r PRESSURE REGULA TOR (SIZE AS SHOWN ON PLAN) PURPLE; RECLAIMeD WATER NON-PRESSURE LATERAL PVC PIPE CLASS~ Xl FOR SIZES 3/4' • 3' W/ PVC SCH. 40 FITTINGS· BURY MIN. 12" Bl::L0W GRADE (SIZE AS NOTE) ON PLAN~ PURPLE RECLAIMED PR.SSURE MAINLINE SCH. 40 PVC IN PLANTER AREA FOR SIZ.S 3/4" • 11/2", FOR 2" & LARGER USE CLASS 315 PVC-BURY MIN. 18' BELOW GRADE (SIZE AS NOTED ON PLAN). PVC SCH 80 SLEEVING, TWICE; THI:: DIAMETER OF PIPE. OR WIRE BUNDLE; CARRleD · l::XTE.ND 12' BeYOND eDGI:: OF PAVING & PLACE BELOW ALL PAVING, HARDSCAPE. ETC.. AND AS DIReCT!;D BY OWNER'S AUTHORIZED RePR.SENTATIVI,. SEE SPECIFICATIONS FOR TYPE, SIZE;, AND DEPTH. IRRIGATION CONTROL WIRE "14UF AWG DIRECT BURIAL (\J.L APPROVED) DS-400 PRE-FILLED DRI WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS VAN NOZZLE KSC-XXX-S SWING CHECK VAL VE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV WHEN RCV IS LOWEA THAN THE SPRINKLcRS KC-XXX-S SPRING Cl-leCK VAL VE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV IMMEDIATE;L V ABOVE; FIRST LATERAL LINE TEE. WHEN RCV IS HIGHeR THAN THE SPRINKLERS N0TeS, ]. IRRIGATION HloADS WITHIN THE. RIGHT-OF-WAY E/7 E/7 H/7 D/8 A/8 C/8 E/ 8 A/7 A/7 B/7 N/A N/A N/A AND WHEREVER THEY ARE WITH IN 10' OF ANY HARDSCAPe TURF OR OTHl,R AREA WHERE; PEDESTRIAN TRAFFIC MAY OCCUR SHALL BE INSTALLED AS POP-UP HEADS t tZONETYPe VALVE SIZE SEE. DETAILFSHE£T-8 ALL OTHERS TO Be INSTALLED ON RISER PeR DH AIL H SHEET 8. 2. CHECK VALVES SHALL BE PROVIDED AS REQUIRED TO PREVENT LOW HEAD DRAINAGE SEE SPECIFICATIONS FOR TYPI,. si:;i;; Sl-l!;(;T 6 TI-IRU: 8 !=OR IRRIGATION DE;TAILS SE;E; SI-IE;E;TS 9 TI-IRU, 10 !=OR IRRIGATION SPE;Cll=ICATIONS PRtSSURt COMPENSATING SCREEN: THE; CONTRACTOR SHALL INST ALL ONE; (1) RAIN BIRD PR ,SSURE; COMPE;NSATING SCRE;E;N PE;R I-IE;AD IN ALL IRRIGATION l''ISTALLATIONS WI-IE;RE; RADIUS R!;DUCTION IS RE;QUIRED. USE; 01= Tl-IE SCRE;E;NS WILL ALSO AID IN MINIMIZING OV!;RSPRA y CONDITIONS AND l=OGGING C \USE;D BY i;;xci;;ss PRE;SSURE;. !=OR SCRE;E;N SE;LE;CTION RE;FE;R TO PRE;SSUR ; COMPE;NSATING SCR!;E;N CHART ON TI-IIS SI-IE;E;T. PRtSSURE NOTE: CONTRACTOR SI-IALL TAKE; STATIC PRE;SSURE; RE;ADING AND RE;PORT PRE;SSURE; TO LANDSCAPE. ARCI-IITECT PRIOR TO ST ART 01= IRRIGATION WORK. CONTRACTOR SAME; ASSUME; l=ULL RE;SPONSIBILITY 01= SYSTE;M II= PRI.SSURE; RE;ADING IS NOT RE.PORTE;D. p L A N D A T E IRRIGATION SLEEVES Sl-lALL BE COORDINATED AND INSTALLED PRIOR TO INSTALLATION OF ANY PAVING, WALL FOOTINGS/ FOUNDATIONS, CURBS ANO ETC. 5. SYSTEMS ARE DE:SIGNoD FOR A MINIMUM OF 30 psi AT SPRINKLER HEADS. CONTRACTOR Sl-lALL VERIFY STATIC WATER PRESSURE AT POINT OF CONNECTION PRIOR TO INSTALLING IRRIGATION SYSTEM. SHOULD STATIC WATER PRESSURE BE LeSS THAN 60 PSI CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT FOR INSTRUCTIONS PRIOR TO PRECE:EDING WITH INSTALLATION. 6. THIS DeSIGN IS DIAGRAMMATIC. ALL EQUIPMENT Sl-l0WN IN PAVED AREAS OR BUILDING IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS AS NECESSARY. 7. DO NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THe PLANS WHEN IT IS OBVIOUS IN THE FIELD Tl-lAT UNKNOWN CONDITIONS eXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WER• PREPARED. ANY SUCH CONDITIONS SHALL Be BROUGHT TO THE ATTENTION OF Tl-lE 0WNoR'S REPRESENTATIVE PRIOR TO ANVWORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. 8. INSTALL ALL EQUIPMENT AS Sl-l0WN IN Tl-l!; DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STA TE llEQUIREM!.NTS FOR BOTH EQUIPMENT AND INSTALLATION. 9. ACTUAL LOCATION FOR TH!. INSTALLATION OF THE AUTOMATICCONrnOLLERS IS TO B!. D!.T!.RMIN!.D IN Tl-lE Fl!.LD BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 10. CONTRACTOR IS TO PROVJDJ; AN ADDITIONAL PILOT WIRE: (AS N0TE:D ON PLANS) TO THE END OF THE MAINLINE RUN IN TWO DIRliCTIONS FROM THe CONTROLLER. 11. ALL PIPE UNDER PAVED AREAS TO BE INSTALLtD IN A PURPLE RECLAIMED SCl-l 80 SL[[VE TWICE THJ; DIAMETER OF THE PIPE CARRIED. ALL WIRE; UNDER PAYED AREAS TO BE INSTALLED IN A PURPLE RECLAIMED SCH. 80 SL!.EYE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEeVeS TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LeAST12' PAST THE EDGE OF THE PAVING. ALL SLEEVES TO BE AS SHOWN ON TH£ PLANS. 12. ALL QUICK COUPLER VAL Y£S TO BE INSTALLED MIN, 6' I MAX 18' FROM HARDSCAPE OR HEADERB0ARD AND IN Sl-lRUB OR GROUND C0YeR AREAS WHERE POSSIBLE.. ALL QUICK C0UPLtR VALVES TO BE INSTALLeD AS Sl-lOWN ON THE INSTALLATION D[TAILS. 13. ALL VAL VE BOXES TO s. PURPLE; IN COLOR, SIZED AS INDICATED av DETAILS, AND HOT BRANDED AS INDICAT!;D ON THE: PLANS AND/ OR D£TAILS. 14. ALL HEADS ARE TO BE INSTALLED WITH THE: NOZZLE, SCREI;N AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT 0VERSPARY ONTO BUILDING. WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEM6NT OF PRESSURE COMPENSATING SCRE:ENS. REPLACEMENT OF NOZZLES WITH MOiie APPROPRIATE RADIUS UNITS AND THE RE:PLACEMENT OJ: NOZZLJ;S WITH ADJUSTABLE ARC UNITS. 15. ALL HEADS INDICATtD ON THE PLANS AT A SPACING LESS THAN 75% OF FULL OPeN THROW, AS PER MANUFACTUR6R'S RE:COMMENDATIONS,ARE TO RECEIVE A PCS SCREEN OF APPROPRIATE SIZE TO RtDUCE THE. RADIUS TO MORE CLOSELY MATCH THE SPACING. REFER TO THE. MANUFACTURER'S CHARTS PROVIDED WITH PCS SCREENS FOR SIZING OF SCREENS. 16. CONTRACTOR SHALL PROTECT IN PLACE ALL EXISTING PLANT MATERIAL AND IRRIGATION EQUIPMENT AND PIPES UNLESS OTHERWISE NOTED. ANY EXISTING PLANT MATERIAL OR IRRIGATION SYSTEMS DAMAGED AS PART OF OR DUE: TO CONSTRUCTION SHALL BE RePAIRED OR REPLACeD TO THE SATIFACTI0N OF THE OWNERS REPRESENTATIVE, AND PRIOR TO PRIOR TO CITY'S ACCEPTANCE OF THE PROJECT. 17. PROYIDt CLeAN SAND BtDDING AND BACKFILL FOR PRESSURE MAINLINE PIPE (3 IN. BELOW AND 6 IN. ABOVE PIPE MINIMUM). 18. IRRIGATION E.QUIPMENT LOCATED IN GE:NliRAL UTILITY EASEMENTS (G.U.E..)SHALL BE INSTALLED IN ACCORDANCE WITH UTILITY COMPANIES' REQUIREMENTS FOR MAT!iRIALS AND MINIMUM SEPARATION. 19. NOTE, SITE DOES NOT CONTAIN DRINKING FOUNTAINS OR ORNAMENTAL PONDS. 20. ALL IRRIGATION EQUIPMENT SHALL BE MARK£D AND C0LOR-C0DeD FOR USE WITH RECYCL[D WATER. MAINLINE LOCATION: MAINLINE; SHOWN WITI-IIN PAVING !=OR CLARITY ONLY, ACTUAL MAINLINE; LOCATION TO BE; A MINIMUM 01= 18" Ol=F ADJACE;NT HARDSCAPE AND OTH!;R OBSTACLE;S TYP. IRRIGATION SYSTEM HEAD LAYOUT: DUE; TO Tl-IE SCALE 01= THIS DRAWING Tl-IE; CONTRACTOR SI-IOULD BE; AWARE OF THE; POSSIBILITY THAT THE; NE;E;D FOR MINOR ADJUSTMENTS TO Tl-IE IRRIGATION SYSTE;M MAY BE; NE.CE;SSARY TO PROVIDE; 100% COVE;RAGE;. THE;SE; ADJUSTME;NTS COULD INCLUDE; NOZZLE. CI-IANGE;S ANC:fOR ADDITION OR DELE;TION 01= INDIVIDUAL I-IE;ADS TO COMPE;NSATE; !=OR CI-IANGES MADE; ON THE; SITE;. APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. 160cto6 1st Submittal I S~ET I CITY OF CARLSBAD I SH:~TS I ---I ---- --- PLANNING DEPARTMENT R E y I s I 0 N s LANDSCAPE IRRIGATION LEGEND & NOT/cS: 7Deco6 2nd Submittal LA COSTA LOT 1.3 RV PARKING 19 Dec:06 3rd Submittal I-. 10Jano7 Final Submltlal I AP~:x:r ·--"· --.,_,,_. --··· -·-· ... --··--... . .. ····· 1 br-E:%l-01t=· 1-14.c'1 PLANNING DATE . --~---'·'·" ..... ---··-···· DWN BY: PROJECT NO. [D~;;.~~O. DATE INITIAL DATE INITIAL DATE IHITIAL CHKO BY: CUP05-03 ENGINEER OF WORI REVISION DESCRIPTION CITY APPROVAL RVWD BY: OTHER APPROVAi.. ' ; ' i ('j • i _, ~------------------------------------------------------------------------------------------------------------------------------------------------l~'. Z:\2-005 P R O J E C T S\05.00B La Costo ,w\DrnwJng FUe-s\CD'o\!RR!C.dwg\Ll-2\9 Jon 2007 12:02 PM by: Glen , •, . . . . .· .. ·'."l · PIPE: DIME:NSION A B C LEGEND [iJ FINISH GRADE [Ij CLEAN COMPACTED BACKFILL -SEE SPECS, FOR MATERIAL IT] UNDISTURBED SOIL [Ij NON-PRESSURE'. LATE'.RAL LINES, SEE SPECIFICATIONS [fil RECYCLtDWATE:RWARNING TAPE ABOVE MAINLINE. m PRESSURE MAINLINE, SEE SPECIFICATIONS II] CONTROL WIRES, St;E SPECIFICATIONS • ALL PLASTIC PIPING TO BE SNAKED IN TRENCI-IES • BUNDLE & TAPE WIRING A TIO' INTERVALS • TIE A LOOSE 20' LOOP IN WIRING OF CHANGES OF DIRECTION GREATER THAN 30'. UNTIE ALL LOOPS At=TER ALL CONNECTIONS HAVE BEEN MADE 1---------------.;c---1----1---• INSTALL ALL CONTROL WIRES ON 3/4' TO 3' IN SIZE: 18' 4" TO 6" IN SIZE; 24' StCTION 12' 4" 4" THE UNDeRSIDE OF THE MAINLINE PIPE -~-1~-~-t _IN_S_T A_L_L~. <~Rt_C_._W_A_T_t~R) __ @ SE:CTION r.--:,- i ffl til I "I I L'_ 11 n n II I I I I II I I ! I I i ' 11 u u I I I--II,--If SECTION LEGEND [iJ STAINLESS STEEL RAIN SENSOR ENCLOSURE W/ MINI CLIK SHUTOFF DEVICE [Ij PANCAKE ANTENNA (IF REQJ m CONTROLLER GNCLOSURE [Ij POURtD CONCRITE BASE-12' MIN. THICKNESS- EXTEND CONCRETE 6" BEYOND OUTSIDE DIMENSIONS OF ENCLOSURE WIT.I½% SLOPE FOR DRAINAGE CENTER OF PAD TO HAVE PEA GRAVEL SUMP [fil IRRIGATION CONTROLLER m PRIMARY llOVAC DUAL LINE SURGE PROTECTION II] CONTROLLER SUB-ASSEMBLY INCLUDES GFI & TERMINAL STRIPS WITH PLACARDS III STATIONTERMINALSTRIPS II] 120-VOLT SERVICE IN CONDUIT Ii§) Y PVC CONDUIT/SWEEP FOR CONTROL WIRES TO VALVES [ill I" PVC CONDUIT/SWEEP FOR FLOW SENSOR/MCV WIRES (IF REQ.) @ FINISH GRADE; @) COMPACTED SUBGRADE -BY CONTRACTOR IE] I" PVC CONDUIT/SWEEP FOR TREPHONE LINE (IF REQ.) [jfil 1¼" PVC CONDUIT/SWEEP FOR ELECTll.lCSt;RVICE ~ o/,," DIA X 96" ELECTRIC GROUND ROD -~~-<?_N_TR_O_L_L_tR_I N_t_N_C_L_O_S_U R_t---1@ [iJ SIDEWALK [Ij CURB 1 1-----... 2 I---.. IT] POil.TABLE SERVIDE LINE [Ij 10' MINIUM TO PORTABLE MAINLINI, IN STREET [fil METER m RECYCLED WATER IRRIGATION MAINLINE W/ SLEEVE tltVATION II] MET!,R BOX m APPROX8' • VERTICAL cu;ARANCE OF 12· MINIMUM IS MANDA TORY WHEN CROSSING PATH OF A POTABLE WATER LINE. INSTALLATION OF RECYCLED WATER IRRIGATION MAINL!No 2A" Fil.OM FACt; OF SIDEWALK WILL PROVIDE THt NtCESSAll.Y 10' .!Oll.lZONTAL CLt;ARANCE FROM POTABLE MAINLINE IN STREET. ~-~; ABLt StRV.LINt CROSSIN~ ()0: 00: 0:0 -LU u,LU LUz ii :l: I-...lu, 3~ --' 0 iil UI 8 u ,---' UI z a 8 DW RW A DW RW A DW ll.W A ow ll.W A DW ll.W A DW Wt,/ A DW ll.W A OW RW A ow Wt,/ A ow RW A DW RW A DW RW A DW RW A 1-Z ZO LU-::i:1- "<( -Z :::i0 o-- LU tll o ARV BV BS COMM Fl FS FVA GR MS MV SI! {STA") QC IDENTIFICATION GUIDE AIR RELIEF VALVE BALL VALVES BASKET STRAINERS COMMUNICATION SPLICES FERTILIZER INJECTORS t=LOWSENSORS FWSH VALVE ASSEMBL V GROUNDING RODS MOISTURE SENSORS MASTER VALVE SPLIClaBOX REMOTE CONTROL V Al VES QUICK COUPLERS CONTACT LANDSCAPE ARCI-IITECT FOR INFO ON ANY DEVICE IN A BOX NOT LISTED. SAMPLE, POTABLE WATER SYSTEM OF CONTROLLER "A" REMOTE CONTROL VAL VE ON STA. "9 PLAN NOTES, A-VAL VE BOXES SHALL BE LABELED BY HOT IRON Bil.ANDING OR ALUMINUM ASPHALTIC BASE WATERPROOF PAINT. B· SEE ALSO INDIVIDUAL VALVE INSTALLATION DETAILS. ~ -~-D L_V_t_B_O_X_ID ____ -----<® • I LEGEND [iJ STREET SURFACE [Ij POT ABLE MAINLINE (SEE IMPROVEMENT DRAWINGS) IT] 12' MIN. REQUIRED VERTICAL SEPARATION [Ij SLEEVE [fil RECYCLEDWATERIRRIGATION MAINLINE SE::CTION 1 2 • ~ I<") 3 - NOTES, • ALL RsCYCLED WATER IRRIGATION PIPE ANO SLEEVES S.!ALL BE PURPLE AND LABELED. • ALL RECYCLED WATER IRRIGATION PIPE AND SLEEVES S.!ALL BE PURPLE AND LABELED. I ~-S>T ABLt MAINLINt CROSSIN<=@) LEGEND [iJ 20"x14" JUMBO RECTANGULAR VAL VE BOX [Ij 16'i<11" STANDARD RECTANGULAR VALVE BOX (fil 10" DIA. ROUND VAL VE BOX [Ij EDGEOFAREA,CURB, WALK OR WALL PLAN NOTES, • CONTROL VALVES S.!ALL BE INSTALLED TO ALLOW ORDERLY ARRANGEMENT OF V Al VE BOXES. • LOCATE VAL VE ASSEMBLIES IN SHRUB OR GROUNDCOVER ARtAS ONLY. • LOCATIONOFVALVE:ASSEMBLIESSHALLBE STAKED FOR APPROVAL BY LANDSCAPE ARC.!ITECT PRIOR TO INSTALLATION. • CENTtR VAL VE BOXt;S OVER VAL VE ASSEMBLE TO FACILITATE ACCESS AND MAINTENANCE. • SET VALVE BOXES AT eQUAL ELeVATIONS w I TOPS AT 'Z' ABOVE FINIS.I GRADE IN S.!RUB/ GROUNDCOVER AREAS. • VALVE BOXES SHALL BESH PARALLEL TO EACH OTH!;R AND PERPENDICULAR TO EDGE OF AREA. • DO NOT DEFORM OR COLLAPSE VALVE BOX BY EXCESSIVE SOIL COMPATION AROUND BOX. • SEt; ALSO INDIVIDUAL VALVE INSTALLATION DETAILS. -~~-LA L_V_t_B_O_X_P_LA_C_t_M_!;:_NT_---1@ INTE;GRATION p L A N D A T i;; r:. liiiiiiiiiiil 160cto6 1st Submittal Di;;SIGN STUDIO R [; V I s I 0 N s ---·-··---· ---- LANDSCAPE; ARCHITtCTS 7Deco6 2nd Submittal 5411 Avenidal:ncinos,Suite270 19 Deco6 3rd Submittal Carlsbad, CA 92008.4380 10Jano7 Rnal Submittal l 760.602.0144 f 760.602.0588 www.tNTliGAATION-D~IGN.-n -----------____ ,, ________ ,,. ______ DATE !NlTIAL ENGINEER OF WOR REVISION C SECTION 24" 21--1 LEGEND [iJ FINISH GRADE ill BRASS NIPPLES MIN. 4" TYP. III R/P oi;vIcE SE• LeGEND FOR SPeCIFICATION G) BRASS BALL VALVE TYP. [fil Bil.ASS ELL 4 REQUIRED m PRESSURE REGULATOR IF SPECIFIED II] BRASS UNION, 2 REQUIRED 2 1 m BRASS RISERS LENGT.t AS REQ. II] PVC MAINLINE-TO BALL VALVE ij§J SCH 60 PVC FEMALE ADAPTER [ill SC.I 80 PVC NIPPLE 6' MIN. @ WATERME:TERBOX(BVCMWD) @) CONCRETE THRUST BLOCK NOTE, • IF WYE STRAINER OR PRESSURE REGULATOR IS SPECIFIED, INSTALL ON EITHER THE; HORIZONT Al PIPING OR ON T.tt; DOWNSTREAM LEG AS SPACE PERMITS. CUP05-03 -~-~-Pl B_A_C_K_J::_LO_W_A_S_S_tM_B_L_Y __ ® PLAN 6 7 SECTION LEGEND [iJ FINISI-I GRADE [Ij MIN. 1 CU FT. GRAVEL III LANDSCAPE FABRIC [Ij 10' ROUND PLASTIC VALVE BOX WIT.I COVt;R .!EAT BRANDED "BV". REFER TO PLANS AND SPECIFICATIONS FOR APPROVED MANUFACTURHIS [fil LINE SIZE BALL VALVE, REFER TO IRRIGATION LEGEND & SPECIFICATIONS m SC.!EDULE 40 PVC MALE ADAPTeR (2 REQUIRED) II] PVC SCH 40 45• RL (4 TVP.) ill SC.tEDULe 40 PVC PRESSURE MAINLINE AS INDICATED ON PLAN II] COMMON BRICK SUPPORT (MIN. 2 REQUIRED) NOTES, • VAL VE BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF BALL VALVE INSTALL AT RIG.IT ANGLE TO HARDSCAPE EDGt, INSTALL VALVE; OFF-CENTER IN BOX. • INSTALL VALVE BOX EXTENSIONS AS RGQUIRED TO ACHIEVE PROPER VALVE INSTALLATION AT MAIN LINE DEPT!-!. • ALL VALVE BOXES TO BE INSTALLED IN GROUND COV~R AREAS. R~~~ll. TO PLAN FOR LOCATIONS. -~~-so L_L_V_A_L_Vt ______ ® --·-------'. ---------------·----------------- ----------··-· -------. -----------·-··" ------···----.. ---------.----------------- DATE INITIAL DATE INJT!AL DESCRIPTION OTHER APPROVAL CITY APPROVAL APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. --------·-· ---·. I SH;ET I CITY OF CARLSBAD SHEETS PLANNING DEPARTMENT 14 LANDSCAP£ IRRIGATION D£TAILS: LA COSTA LOT 1.3 RV PARKING IAPr-£,~~j ¢3:~~ !-~'l.o-1 I PLANNING DATE ----------···------~--~ ---··~~--·" ~ . DWN BY, PROJECT NO. DRAWING NO. CHKO BY: CUP05-03 442-?L RVWD BY: t? ! ,_ ___________________________________________________________________ ..;_. ___ ..,... _____________________________________________________________________ __,J Z:\2005 P R O J f C T S\05.008 lo C0-,to RV\Orowin9 riles\CO's\lDElS.dwg:\U-2\9 Jon 2007 8:48 AM by: Stotionj •'.Q+F.ilflf.,--------l 5 T " =1n, i----------; 6 --------;10 LEGEND OJ FINISHED GRADE IN TURF AREAS, III PLASTICROUNDVALVEBOXWITHBOLT DOWN COVER HEAT BRAND "QCV" ONTO LID • REFER TO PLANS AND SPECIFICATIONS FOR APPROVED MANUFACTURERS [Ij QUICK COUPLER KEY WITH MALE HOSE BIB CONNECTION AS SHOWN, KEY MUST CLEAR VALVE BOX 8) FINISHED GRADE IN SHRUB AREAS III UNDlSTUR[D SOIL III QUICKCOUPLE:RVALV[S[[l[GENDFOR SPEC.· LOCATE PER PLAN II] STAINLESS STEEL CLAMP [fil 3/4" ROCK, 1 CUBIC FT. III BRICK SUPPORTS lj§) DURA PRE-ASS£MBLsD SWING JOINT WITH ONE PIECE BRASS MIPT NIPPLE MODsL • 1-A1912 [fil PRESSURE MAINLINE -SEE SPECS. [jfil •4x36"REBARSTAKES-2 REQUIRED @J LANDSCAPE FABRIC NOTE, • USE TEFLON TAPE ON ALL THREADED CONNECTIONS • QCV SHALL BE A TYPE APPROVED FOR RECLAIMED WATER USE. 2 ~~-~I_C_K_C_O_U_PL_l;_R ___ ---1@ I -~ 0 00X ., y RCV ::,, "' q -6: ,, '· ,( ' \'. ' XH ,'<. ' » PLAN SE.CTION ' :2; ¢ 1 X c• -':/ LEGEND OJ VALVE BOX ID(SEE DeTAIL THIS SHEET) III PVC NON-PRESSURE LATERAL LINE III FINISH GRADE 0 30" LINEAR LE:NGTH OF WIRE, COILeD III WATERPROOF CONNECTION (l OF 2) III ID TAG-'T. CHRISTY' (714) 507-3300 r., PLASTIC RECTANGULARVALVEBOXW/BOLT ~ DOWNCOVsR m PVC SCH 80 NIPPLE (LENGTH AS Rt;QU!RED) III 1· IN TURF AREAS, 3" IN SHRUB AReAS lj§) PVC SCH 40 ELL PVC [fil PVC SCH 40 PRESSURE MAINLINE @) BRICK SUPPORT O OF 4) @) PVC SCH 40 TEE OR {;LL IEJ SCH 80 NIPPLE (2" LENGTH, HIDD,N) & SCH 40ELL @) LANDSCAPE FABRIC ~ ELECTRIC REMOTE CONTROL VALVE -REFER TO IRRIGATION LEGEND FOR SPEC. (ill 3" MIN. DEPTH OF 3/4" CRUSHED GRAVEL (@ SCH 80 UNION []2) PVC SCH 40 FEMALE ADAPTER -~-~-OlM_O_T_l;_C_O_N_TR_O_L_V A_L_V_~--1® SE.CTION 2 3 ,--- L __ _ LEGEND OJ LOWVOLTAGEWIRES.3MAXIMUM III OUTER CASE OF CONNECTOR [II STRIP AND TWIST WIRf;S FOR PROPER CONNECTION 8) CRIMP COPPtR SLtE,Vt INSTALLED WITH RECOMMENDED TOOL III CONNECTOR INSERT LEGEND • FILL OUTER CASE WITH SEAL•R PRIOR TO FINAL ASS£MBL V. 4 5 W_CON--~R~_l;_C_O_N_N_l;C_T_IO_N __ ----1® 6" MIN. SE.CTION LEGEND OJ EDGG OF PAVING III FINISHED GRADE 'Z' BELOW PAVING IN GROUND COVER III SPRAY OR STREAM 12· HIGH POP-UP SHRUB HEAD -SET TOP OF HEAD½• ABOVE FINISH GRAD!; 0 UNDISTURED SOIL III PVC SCH 60 NIPPLE (LENGTH AS REQUIRED) III NON PRESSURE LATERAL LINE, SEE SPECIFICATIONS FOR TYPE AND DEPTH REQUIRED II] PRE-ASSEMBLED TRIPLE SWING JOINT, PVC TVPe, WITH 0-RINGED JOINTS. MIPT INLET AND MIPT OUTLE:T LAV 1£NGTH TO BE. 6" MINIMUM SIZE AS PER SPRINKLER OUTLET, [fil PVCSCH40TeEORELL NOTE, • INSTALL SPRINKLER HEADS PLUMB. ADJUST SPRAYS OR NOZZLE STR!oAM TO COVER LANDSCAPe AREA WITHOUT OVER SPRAY ONTO PAVING, FENCf;S, WALLS OR BUILDINGS. -------' 12" I-IIGI-I POP-UP SPRAYl-ll;AD ® SPV-12B I ,_~OSCAP ~ehan -\ .s,, ~ .., ... s g a; u ...I ~ UJ Cl Q, z a: 0 UJ 1-UJ <( V) ...I ...I i PLAN SE.CTION /4 . " ., 0 ""' "' ," ' RCV )'> "" :,s: ,, <;<': ' ,, ~.::xx ~ / 1 LEGEND (jJ VAL VE BOX ID {SEE DETAIL THIS SHEIT) II] PVC PR.SSURE. MAINLINE PIPE III FINISH GRADE· I" IN TURF . AReAS, 3" IN SHRUB AREAS 0 PVC SCH 40 45" ELL (4 TYP.) III PLASTIC RECTANGULAR VALVE BOX W/ BOLT DOWN COVER III MASTER CONTROL VALVE -SEE !£GENO FOR SPE:C II] WATERPROOFCONNECTIONI OF 2 (SEE SPECSJ m ID TAG-'T. CHRISTY' (714) 507-3300 III CONTROL WIRES; BUNDLE AND TAPE CN / 24" MIN, LINEAR LENGTH OF EXTRA WIRE:) lj§) BRASS UNION [fil BRASS NIPPLE (TYP,) (LENGTH AS REQUIRED) '..._,,__, @) UNDISTURBED/ COMPACTED '-I..µ., @] SUBGRADE 2CU, FT. MIN. P•A GRAVEL IE! LANDSCAPE FABRIC @) BRICK OR CONCRETE SUPPORTS -~M-!S_T_l;_R _C_O_NT_R_O_L_V_A_L V_I; __ @) SECTION LEGEND OJ RAINBIRD 10H NOZZLE SPACE HEADS TO ACHIEVE 80%COVERAGE III cHeCKVALVE,ASREQUIRED III MARLEX UVR SCH 80 STREET ELL 0 UVR PVC SCH 40 PIPE III PIPE STABILIZER III FINISH GRADE III PLANTABLE RETAINING WALL [fil 8' UVR PVC SCH 40, THREADED RISER III COVER PVC SCH 80 ELL lj§) CONNECT TO LATERAL LINE NOTE, • TO IRRIGATE PLANTING AT THE TOP OF THE WALL, S{;T THE ARC ON THE ADJUSTABLE ARC NOZZLE: BETWEEN 245° AND 255° ~ _LE __ IRRR_D_U_R_A_W_A_L_L_-S_P_R_A_Y __ ® INTEGRATION p L A N D A T E ~iiiiiiiiliiil 160clo6 1st Submittal DESIGN STUD 10 R E V I s I 0 N s LANDSCAPE ARCl;ITI;;CTS 7 Dec06 2nd Submittal 5411 Avenido tneinos, Suite 270 19 Deeo6 3rd Submittal Carlsbad, CA 92008.4580 10Jan07 Final Submittal t 760.602.0144 f 760.602.0388 www.lNTEGRATION-DE::SIGN.com DATE INITIAL ENGINEER or WOR REVISION CUP05-03 LEGEND MASTER VAL VE SEE DITAIL OJ PVC PR!;SSURE SUPPLY LINE III PVC REDUCING COUPLER ·2 REQ. (II FINISH GRADE -1" IN TURF AREAS, 3' IN SHRUB ARtAS GI PLASTIC RECTANGULAR VALVE BOX W/BOLTDOWNCOVER III 8" DIA. CL 160 PVC SLEEVE BOTTOM TO BE FLARED & CONTACT TOP OF PRESSURE; SUPPLY LINE III 1 CU, FT, MIN. OF%" GRAVE:L SE.CTION 4 III CONDUIT BUSHING FLOW SENSOR [fil SENSOR CABLE TO CONTROLLER -REFER TO IRRIGATION PLANS III MINIMUM DISTANCE DOWNSTREAM 5X DIAMETER OF FLOW MeTER SIZE. lj§) MINIMUM DISTANCE UPSTREAM lOX DIAMETER OF FLOW METER Sin;. NOTES, • VAL VE BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF FLOW SENSOR • INSTALL VAL VE BOX EXTENSIONS AS REQUIRED TO ACHIEVE PROPER FLOW SE:NSOR INSTALLATION AT MAIN LINE DEPTH. • All VALVE BOXES TO BE INSTALLED IN GROUND COVER _F_L_O_W __ S_l;_N_S_O_R __ AR_EAS_, -RE-FER-TO_PLA_N F-O-RL-OC-AT-10-NS_. -,@D FLO·SEl SECTION f-----------16 ------------------m ~---17 LEGEND OJ SPRAY /BUBBLER HEAD • SEE !£GENO FOR SPECIFICATION III SCH 80 PVC NIPPLE, TWO REQUIRED LENGTHS AS RE:QUIRED III SPRING TYPE ANTI-DRAIN VALVE 0 FINISHED GRADE III UNDISTURBED SOIL III SCH 40 PVC THREADED COUPLING III PRE-ASSEMBLED TRIPLE SWING JOINT, PVC TYPE, WITH 0-RINGED JOINTS, MIPT INLET ANDMIPTOUTLET LAY LENGTH TO Bs 6" MINIMUM SIZE AS PtR SPRINKLER OUTLtT, @) SCH40PVCSxSxTTE£FITTING LATERAL x SPRINKLER INLET SIZE III NON PR.SSURE LATERAL LINE. SEE SPECIFICATIONS FOR TYPE AND DEPTH REQUIRED ~v~RUB SPRAY l-ll;AD ON RIStR @ APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ··-------·------------I SH~ET I CITY OF CARLSBAD ~ PLANNING DEPARTMENT 4 LANDSCA.0 [ IRRIGATION DETAILS: -----·---·---.. ----~ _,,_, ___ ·-----~---LA COST A LOT 1.3 RV PARKING I APPROVED ~( ~. ~\* I 1.1, • .:-1 PLANNING DATE . __ ,,,_ ""'' " -~---" --------------OWN BY, PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY, CUPOS-03 442-7L DESCRIPTION RVWD BY: OTHER APPROVAL CITY APPROVAL -.:::I' ' '--------------------------------------------------------------------------------------------------------------------------------------------------------------~_) Z:\2005 P R O J E C T S\05.008 Lo Costo RV\Drov,ing nlea\CO's\!OUS.dwg\U-3\9 Jon 2007 12:51 PM by: Glen LANDSCAPE IRRIGATION SPECll=ICA TIONS 1. SCOPI.: PllOVIDe LABOll, MATERIALS, PERMITS, EQUIPMENT, SUPERVISION, SERVIC£S AND TRANSPORTATION AND ALL OTHrn IT[MS N[CESSARY TO PeRFORM ALL IRRIGATION WORK AS INDICATED AND SPECIFIED ON PLANS PREPARED BY INTEGRATION DESIGN STUDIO, INCLUDING ALL R£CORD DRAWINGS, RtDUCED DIAGRAMMATIC PLANS, GUARANTLES, AND ScRVICE MANUALS. WORK SHALL BE COMPLETED IN AN EFFICIENT AND SATISFACTORY MANN!=R TO THE HIGHEST WORKMANLIKE STANDARDS ESTABLISHED FOR SPRINKLSR INSTALLATION AND OP£RA TION. 2. G!;;N!;'.RAL CONDITIONS: A. CONTRACTOR SHALL VGRIFY ALL CONDITIONS INDICATED ON THE PLANS. CONTRACTOR SHALL NOTll=Y OWNGR'S REPRESENTATIVE IN WRITING OF ANY DISCREPANCIES IN THE PLA.NS AND FlfLD CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. FAILURE TO NOTIFY TH£ OWNER'S REPRESENTATIVE IN WRITIMG EXEMPTS THE CONTRACTOR FROM GAINING COMPENSATION FOR REQUIRED CHANGES. B. CONTRACTOR SI-IALL CH£CK ALL SITE CONDITIONS, AND VERIFY THE EXISTENCE, LOCATION AND SIZE OF UTILITIES AND SERVICl=S PRIOR TO BEGINNING WORK. C. THE IRRIGATION DESIGN AS INDICATED ON THE DRAWINGS IS DIAGRAMMATIC. SCALED DIMENSIONS AR[; APPROXIMATE. BE FOR[ PROCE[DING WIT! I WORK, CHECK AND VERIFY SITE DIMENSIONS. D. DO NOT INSTALL THE IRRIGATION SYSTEMS WH[N UNKNOWN OBSTRUCTIONS, CRADE DIFFERENCES OR DISCREPANCIES IN AREAS OR DIMENSIONS EXIST. IMMLDIATLLY BRING DISCREPANCIES TO THE ATTENTION OF Tl-IE OWNER'S REPRESENTATIVE. IF NOTlrlCATION IS NOT GIVEN, THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR R[QUIRED REVISIONS AND COSTS. E. CONTRACTOR SHALL COORDINATE INSTALLATION OF IRRIGATION WORK TO AVOID CONFLICTS WITH PLANTING, UTILITIES, 1:NGINEERING AND ARCHITECTURAL FEATURES. CONTRACTOR IS R[SPONSIBL[ t=OR COORDINATING HIS WORK WITH OTHeR TRADES. F. CONTRACTOR SHALL PROTECT INSTALLED CONTRACT WORK AND WORK OF OTHERS. G. CONTRACTOR Sf.IA.LL APPLY AND PAY FOR NECESSARY PERMITS AND FEES REQUIRED IN PURSUIT or: WORK AS REQUIR£D BY GOVERNING CODES. H. LOCAL, MUNICIPAL AND STATE LAWS. llULES AND RLGULAllONS GOV£RNING OR RELATED TO A PORTION OF THIS WORK ARE f.leRsBY MADE A PART 01- TH ESE SPECIFICATIONS. i. CONTR,\CTOR SHALL KEEP PREMISES CLEAN AND FREE OF EXCESS EQUIPMENT, MATERIALS AND RUBBISH INCIDENTAL TO WORK DURING CONSTRUCTION AND MAINTENANCE PERIOD. BROOM CLEAN ALL PAVED AREAS. J. CONTRACTOR SHALL NOTE ALL FINISH GRADES BEFORE COMMENCING WORK. RESTORE FINISH GRADE CHANGED DURING COURSE OF THIS WORK TO ORIGINAL OR IN ILNDE[) CONTOURS WHERE PRACTICAL. K. NO DEVIATION FROM PLANS AND SPECIFICATIONS IS AUTHORIZED, UNLESS WRITTEN AUTHORIZATION IS OBTAINED FROM THE OWNER'S REPRlcSENTATIVE OR HIS APPOINTED REPRESENTATIVE IN ADVANCE. L. THE CONTRACTOR SHALL OBTAIN AN ENCROACHMsNT REMOVAL AGRlceMENT IF REQUIRED FOR ALL IRRIGATION i,QUIPM[NT LOCATED WITHIN PUBLIC RIGHT OF WAY. M. CONTRACTOR SHALL REUSE EXISTING IRRIGATION EQUIPMENT WHICH IS IN PROPeR WORKING CONDITION. A UST OF EQUIPMENT TO BE REUSED SHALL BE SUBMITTED TO OWNER'S REPRESENTATIVE FOR APPROVAL. 3, SPECIAL NOTES: CONTRACTOR SHALL Vl::RIFV IN THE FlfLD THAT ALL IRRIGATION DESIGN ASSUMPTIONS INDICATED BELOW ARE CORRECT. CONTRACTOR SHALL NOTIFY OWNGQ'S REPR!;Sf:;NTATIV[ IN WRITING OF ANY DISCR[;PANCIES IN nu; SPECIFICATIONS, PLANS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND AT ANY TIM[ DURING WORK. FAILURE TO NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING EXEMPTS TelE CONTRACTOR FROM GAINING COMPENSATION FOR CHANGES. A. IRRIGATION METERS ARE ASSUMED TO EXIST AT THE FOLLOWING LOCATION, 1. 11/2" WATER METER AT APPROXIMATl:L Y STATON POiNT19,50, B. SLOPES TEN f'EET (10') AND HIGHER IN VERTICAL ELEVATION SHALL BE IRRIGATED WITH A PERMANENT BELOW GRADE SYSTEM. SLOPr::S FIVE TO TEN FEE'T (5'-10') WILL BE IRRIGATED FROM A HOSE BIBB. RECLAIMED WATI.R usi;; NOTES: A. THE RECLAIMED IRRIGATION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE GUIDELINES FOR DISTRIBUTION OF NON- POTABLE WATER DEVELOPED BY THE AMERICAN WATER WORKS ASSOCIATION (AWWA} CALIFORNIA NEVADA SECTION, Tf-lE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD REQUIREMENTS, TITLE 17, CHAPTER s, AND TITLE 22, CHAPTER 3 OF Tl-IE CALIFORNIA ADMINISTRATIVE; corn;, THE CITY OF CARLSBAD RULES AND REGULATIONS FOR RECLAIMED WATER USE. B. ALL OFFSITE; AND ONSITE RECLAIMED WATER SYSTEM PIPING SHALL BE IDENTIFt[D AS RECLAIMED WATER IN ACCORDANCE WITH THE PROVISIONS OF THESE RULES AND RE;GULATIONS. C, WHERE RECLAIMED WATER USE AREAS CONTAIN POTABLE AND RECLAIMED WATER PIPING, THE POTABLE WATER PIPING SHALL ALSO BE IDENTIFIED IN ACCORDANCE WITl-l THE PROVISIONS OF THESE RULES AND REGULATIONS. D. THE CITY SHALL BE NOTIFIED 24 flOURS PRIOR TO START OF ANY CONSTRUCTION. NO CONSTRUCTION SHALL START WITHOUT THE CONSENT OF THE CITY OF CARLSBAD. L THE RECLAIMED IRRIGATION SYSTEM INCLUDING OFFSITE AND ONSITE i=ACILITIES SHALL BE SEPARATE AND INDEPENDENT OF ANY POT ABLE WATER SYSTEM. CROSS-CONNE'CTIONS BETWE[N RECLAIMED WATER LINES AND POTABLE WATER LINE':S ARE STRICTLY PROHIBITED. F. THE CITY OF CARLSBAD WILL INSPECT THE CONSTRUCTION OF CUSTOMER FACILITIES TI-IAT WILL USE OR RECEIVE RE=CLAIMED WATER TO VERIFY THAT THE CUSTOMER FACILITIES ARE CONSTRUCTED IN CONFORMANCE WITH THE PLANS AND SPECl/:'.ICATIOt-.JS. INSPECTION TIMES WILL BE= i:::STABLISHE=D AT THE PRE JOB MEETING, G. AN ANNUAL CROSS CONNECTION INSPECTION WILL BE DONE BY THE CARLSBAD MUNICPAL WATER DISTRICT. INSPECTION REPORTS MUST BE FORWARDED TO NON-INSPECTING PARTIES, H. Tl-IE IRRIGATION SYSTEM SHALL OPERATE BETWEEN THE HOURS OF 9,00 P.M. TO 6,oo A.M. T•IE FOLLOWING MORNING, OR AS ALLOWf'D BY THE CITY Oi= CARLSBAD. L THE: CONTRACTOR SHALL IRRIGATE: IN A MANNER THAT WILL MINIMIZE RUN-OFF, POOLING AND PONDING. THE APPLICATION RATE SHALL NOT EXCEED THE INFILTRATION RATE OF THE SOIL CONTROLLER OPl':RATION TIMES MUST BE ADJUSTED SO AS TO BE COMPATIBLE: WITH THE LOWEST SOIL INFILTRATION RATE PRESENT. THIS PROCEDURE MAY BE FACILITATED BY THE EFFICIENT SCHEDULING OF Tl-IE AUTOMATIC CONTROL CLOCKS. (I.E., E;MPLOYING THE: Ri':PEAT FUNCTION TO BREAK UP THE TOTAL IRRIGATION TIME INTO CYCLES THAT WILL PROMOTE MAXIMUM SOIL ABSORPTION). J. THE CONTRACTOR SI-IALL ADJUST SPRAY HEADS TO ELIMINATE OVERSPRAY ONTO PUBLIC FACIUTIE=S, PRIVATE LOTS, STREETS, SIDEWALKS, ETC. K. CONDITIONS THAT DIRECTLY OR INDIRECTLY CAUSE RUN-OFF OF RECLAIMED WATER OUTSID[ THE APPROVED RE'CLAIMl':D WATE'R USE ARE=A, OR CAUSE A PONDING 01= RECLAIMED WATER OR PERMIT WINDBLOWN SPRAY TO PASS OUTSIDE OF THE APPROVED USE AREA, WHETI-IER BY DESIGN, CONSTRUCTION PRACTICE, OR SYSTEM OPERATION, SHALL BE i:::LIMINATt=D OR CONTROLLED TO THE GREATEST EXTENT POSSIBLE WITH THE USE OF THE BEST PRACTICABLE TECHNOLOGY AND METHODOLOGY. L THE CONTRACTOR SHALL MONITOR AND MAINTAIN THE SYSTEM TO MINIMIZE EQUIPMENT AND MATERIAL FAILURE. BROKEN SPRINKLER 1-11":ADS, LE':AKS, UNRELIABLE VALvi:::s, ETC., SHOULD BE': REPAIRED AS SOON AS THEY BECOME APPARENT. M. THE CONTRACTOR SHALL INSTALL ALL Rl:.CLAIMl".D \/I/ATER LINES AND POTABLE WAT[R LIN[S SO TI-IAT Tl-IE; IDE'NTIFICATION STE'NCILING IS ORIENTED TOWARDS THE TOP OF THE TRENCH. N. THE CONTRACTOR SHALL EDUCATE ALL MAINTENANCE PERSONNEL, ON A CONTINUOUS BASIS, OF THE PRESENCE OF RECLAIMED WATER AND THE !=ACT THAT IS NOT APPROVED FOR DRINKING PURPOSES. 0. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL OF ALI. PROPOSED CHANG!cS AND MODll=ICATIONS TO ANY (PRiVATF.) ON- SITE FACILITll'.:S. P. HOSE BIBS ON RECLAIMED WATER FACILITIES ARE STRICTLY PROHIBITED. Q. NO SUBSTITUTION OF PIPE MAT!=:RIALS WILL Br: ALLOWFD WITHOUT PRIOR WRITTEN APPROVAL OF THE CITY OF CARLSBAD R. WHEN RECLAIMED WATER BECOMES AVAILABLE, AN ON-SITE USER/SUPERVISOR SHALL BE DE=SIGNATr::D IN WRITING. THIS INDIVIDUAL SHALL Bi::: FAMILIAR WITH PLUMBING SYSEMS WITHIN THE= PROPERTY, WITH THi::: BASIC CONCEPTS OF BACKFLOW/CROSS CONNECTION PROTECTION, THE RECLAIMED PURVEYOR'S RULES AND REGULATIONS, AND THE SPECIFIC REQUIREMENTS OF A RECLAIMED WATER SYSTEM. COPIES OF THE DESIGNATION, WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE CARLBAD MUNICIPAL WATE;R DISTRICT IN CASE: OF J;MeRGt;NCY, CONTACT,MIKG LOMBARDI AT 760 -505-5644 OR AFTJ;R HOURS, CONTACT, MIKG LOt,JBAR.QlAT 760 ·505·5644 S. Tl-IE PROPOSED Rr::CLAIMED WATE;R IRRIGATION SYSTEM SHOWN ON TI-IESE PLANS SI-IALL BE; St;RVICED BY POTABLE WATER UNTIL SUCH A TIME WHEN RECLAIMED WATER IS AVAILABLE. PRIOR TO THE CONVERSION OF RECLAIMED WATER THE CONTRACTOR SHALL MINIMIZE ALL TEMPORARY CONNECTIONS AS ACCEPTABLE BY THE CITY OF CARLSBAD WATER UTILITIES SYSTEMS DIVISIOMS. T. THE CONTRACTOR SHALL CONDUCT A CROSS-CONNECTION TEST AND A COVE=RAGE TEST AS DIRE:CTE=D BY THE CITY CARLBAD AND/OR THE CARLBAD MUNICIPAL WATER DISTRICT, PRIOR TO ANY USE OF RECLAIMED WATER. SUBMITTAL: CONTRACTOR'S MAINTENANCE PERIOD SIIALL NOT BE TERMINATED UNTIL THE FOLLOWING CONDITIONS ARE MH, A. RECORD DRAWINGS, 1. CONTRACTOR SHALL R[CORD WORK AS IT IS ACTUALLY INSTALLED ON AN ERASABLE xrnox V[LLUM BASE OF THE IRRIGATION DRAWING, MAKE CHANGES TO XEROX Vf;LLlJM BASE IN INK [NO BALL POINT PEN), AND MAINTAIN CURRENT R[CORD DRAWINGS ON THE SITE. THE FINAL 'AS BUil T' RECORD DRAWINGS SHALL BE DRAFTED EMPLOYING A COMPETENT DRAFTSMAN. 2. RJ;CORD DIMeNSIONS FROM TWO DIFFERENT PeRMANENT POINTS OF RE:FERENCE (BUILDINGS, MONUMENTS, CURB RETURNS, ETC.) FOR THI; FOLLOWING IT£MS, a, WATER METER AND BACKFLOW ASSEMBLY b. CONNECTIONS TO EXISTING WATER LINES c. BALL, QUICK COUPLING AND AUTOMATIC CONTROL VALVES d. ROUTING OF PRESSURE LINhS e. SOURCE OF ELECTRICAL POWER FOR CONTROLLER, LOCATION OF CONDUIT AND CONDUCTORS FROM SOURCE TO CONTROLLER, ROUTING OF ELECTRICAL WIRES, AND SPARE WIRF LOCATIONS f. PIPE AND ELECTRICAL SLEEVES g. IRRIGATION HEADS HAViNG A DESIGN RADIUS OF 30' OR MORE 3. CONTRACTOR SHALL SUBMIT ON[ S[T OF COMPLETED R[CORD DRAWINGS TO THE OWNER'S R[PR[SENTATIVE PRIOR TO THE BEGINNING OF THE SPECIFIED MAINTGNANCE PERIOD AND OWNEll'S REPRESENTATIVE SHALL VERtr-Y COMPLETENESS PRIOR TO FINAL ACCtPTANCE. 4. THE FINAL "AS BUILT" PLANS SHALL BE PRePARED BY THE LANDSCAPE ARCHTECT BASED ON THE SET PROVIDED BY TH[ CONTRACTOR. FINAL "AS BUILTS" SHALL BE DRArTED CLEARLY TO THE SATISFACTION OF THE CITY. THE ORIGINAL MYLARS SHALL BE SUBMITTED TO THE CITY FOR THEIR KEEPING. B. CONTROLLER CHARTS, THE CONTRACTOR SHALL PRE:PARE THE CONTROLL[;R CHARTS AND PLACE THEM IN THE CONTROLLERS BEFORE COMMENCING srnvIc.;. CONTRACTOR SHALL vrn1FY COMPLGTENESS OF RECORD DRAWINGS WITH OWN[R'S RGPRESENTATIVE PRIOR TO PREPARING THE: CONTROLL.R CHARTS. THE CONTROLLER CHARTS SHALL BE PREPARJ;D AS FOLLOWS, 1. PROVIDE ON[ CONTROLLeR CHART FOR EACH AUTOMATIC CONTROLLER SHOWING THE AREA COVERED BY THE CONTROLLtR. THE CHART MUST SHOW CLEARLY ALL AREAS UTILIZING R[CLAINED IRRIGATION WATER AND POTABL[ IRRIGATION WATER. THE CHART SHALL BE THE MAXIMUM SIZE THE CONTROLLGR DOOR WILL ALLOW. 2. THE CHART IS TO BE A R[DUCED DRAWING OF THE ACTUAL AS-BUILT SYSTE:M. THE LINE WEIGHTS AND LETTERING ON THE ORIGINAL CONTROLLER CHART DRAWING SHALL BE SO DRAWN HIATTHE REDUCED CHART IS CLEAllL Y READABLE. 8, ._\U)SCAP !j ~ ..J _,.,'~"-'~W~~~~::; -< OF C1'1.I 3. THE CHART SHALL BE A BLACKLINE PRINT WITH A DIFFERENT COLOR USED TO SHOW AREA OF COVERAGE FOR EACH STATION. 4. WHEN COMPLETED AND APPROV[D, THE CHARTS SHALL BE HERMETICALLY SEALED BETWeEN TWO PIECES OF PLASTIC, EACH PIECE BEING A MIN!MUM OF TEN (10) MILS THICK, C. SERVICE MANUALS, KEYS, EQUIPMENT, AND GUARANTEES, 1. CONTRACTOR SHALL SUBMIT TWO (2) S[RVICE MANUALS FOR IRRIGATION EQUIPMENT TO OWNtR'S RE:PRhSENTATIVE. MANUALS MAV BE LOOSE LEAF AND SHALL CONTAIN COMPLETE DRAWINGS OF ALL EQUIPMENT INSTALLED SHOWING COMPONENTS AND CATALOG NUMBERS TOGETHER WITH TH[ MANUFACTURrn'S NAME AND ADDR£SS. OPERATION INSTRUCTIONS SHALL BE SIMPLE ENOUGH TO BE UNDf;RSTOOD WITHOUT SPE:CIALIZED KNOWLEDGE. 2. CONTRACTOR SHALL SUBMIT TWO (2) SETS OF KEYS PER EACH CONTROLLER. A COPY OF THE EQUIPMlcNT GUARANT[[S SHALL BE· PROVIDED TO THE OWNER'S REPRESENTATIVE. 3. THE CONTRACTOR SHALL SUPPLY THE FOLLOWING TOOLS, a. TWO (2) sns OF SPECIAL TOOLS R[QUIRED FOR REMOVING, DISASSEMBLING, AND ADJUSTING EACH TYPE OF SPRINKLEll AND VALVE ON THIS PROJECT. b. ONE (1) QUICK COUPLER KEY AND MATCHING HOSE SWIVEL FOR [ACH TYPE or QUICK COUPLING VAI.V[ INSTALLED. WATER SUPPLY: A. GEN[RAL 1. WHEN THE PROJECT IS SERVED BY RECLAIMED WATrn AND IS ALSO SERVED BY POTABLE WATER SYSTEMS AND PIPING, THE EXPOSED PORTIONS OF TH[ PIPELINES S>-IALL BE PAINTED, BANDED OR MARKED TO DISTINGUISH CLEARLY WHICH IS USED eOR POTABLE: WATER AND WHICH IS USED FOR RECLAIMED WATER. IN ADDITION, ALL NEW UN[XPOSED PIPES INSTALLED ON ANY SUCH PROPERTY SHALL BE SIMILARLY PAINTED, BONDED OR MARKED. ALL RECLAIMED WATER OUTLETS SHALL BE POSTED WITH BILINGUAL PRECAUTIONARY SIGNS. MAIN SHUT-OFF VALVES SHALL BE Cl.EARLY IDENTIFl[D TO DISTINGUISH BETWEEN RECLAIMED WATE:R AND POT ABU:: WAT[R. 2. ALL CONNECTIONS TO RECLAIM[D WAT[R SYSlEMS SHALL BE IDENTIFIED IN SUCH A MANNER AS TO DIFFERENTIATE THEM r:ROM CONN[CTIONS TO POTABLE WATER SYSTEM. 3. NO CROSS CONNECTIONS BETWEEN POTABLE WATER AND RECLAIMED WATER ARE PERMITTED. B. WATER SERVICfi 1. INDIVIDUALLY ASSESSED ARGAS AND INDIVIDUALLY OWNED (OR TO Be OWNED) LOTS SHALL HAVE SEPARATbLY METERED AND CONTROLLED llln!GATION SYSTEMS. IRRIGATION SHALL BE CONFINED TO THE INDIVIDUAL AREAS, WITHOUT OVERSPRAY ONTO ADJACENT AREAS OR ACROSS PROPERTY LINES. SPECIAL SITUATIONS MAY BE APPROVED OR REQUIRED BY THE PLANNING DIRECTOR ARCHITECT TO VARY FROM THESE REQUIREMENTS. 2. CITY APPROVED BACKFLOW PREVENTION UNITS ARE REQUIRED ON ALL IRRIGATION SYSTEMS. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE HEALTH AND SAFETY CODES. 3, OPEN SPACE AREAS AND STREET RIGHTS-OF-WAY IRRIGATION SYSTEMS SHALL BE AUTOMATED AND SHALL HAVE THEIR OWN WATsR METERS AND SERVICES UNLESS TH[Y ARE A PART OF THE SAME MAINTENANCE ASSESSMENT DISTRICT, Wl1EREBY, THEY MAY THeN SHARE THE SAME METER AND SERVICE. 4. A GUARD FENCE OR STAINLESS STEEL ENCLOSURE WILL Be INSTALLED TO PROTECT BACKl'LOW PREVENTION UNITS IF TH[ UNITS ARE LOCATED WITHIN FIVE FJ;ETQF A PEDeSTRIAN TRAVeL WAY. 5. THERE WILL BE NO SHARING OF WATER WITH PRIVATE PROPERTY. 6. CONTACT WATER UTILITIES SERVICE DIVISION (53.3·4100) FOR WATER SERVICE INFORMATION. GUARANTEE: GUARANTH, THE CONTRACTOR'S GUARANTEE SHALL CONSIST OF St;CTION 30$-7 OF THE STANDARD SPECIFICATIONS AND THE FOLLOWING, THE ENTIRE IRRIGATION SYSTEM SHALL BE GUARANTE:ED AGAINST Dt;FECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) VEAR FROM THE DATE OE ACCEPTANCE OF WORK. SHOULD THE CONTRACTOR FAIL DURING THE GUARANTEE PERIOD TO EXPEDITIOUSLY CORRECT A DEFECT UPON WRITTEN NOTIFICATION BY THE CITY, THE CITY SHALL CAUS[ THE WORK TO BE CORRECTED AND BILL TH£ ACTUAL COSTS INCURRlcD TO THE CONTRACTOR. DEFECT CORRJ;CTIONS SHALL INCLUDE THt; COMPLETE RESTORATION or EXISTING IMPROVEMENTS THAT WERE DAMAGED AS A RESULT OF THE DEFECT. MATERIALS: A. GENERAL 1. PROV! D[ NeW MATERIALS AND EQUIPMENT OF BEST QUALITY OBTAINABLE, WHICH COMPLY WITH DRAWINGSANDSPEC!clCATIONS. 2. NO SUBSTITUTION OF SPECIFIED MATERIALS OR EQUIPMENT Sl1ALL BE MADE WITHOUT REVIEW BY INTEGRATION DESIGN STUDIO AND WRITTeN APPROVAL FROM THe OWNER'S RePRESeNTATIVe. 3. ALL PRESSURe PIPE INSTALLED ABOVE GROUND SHALL BE GALVANIZED STea SCHEDULE 40 PIPE, OR UV RESIST ANT PVC. B. IRRIGATION PIP£ AND FITTINGS, 1. RECLAIMED PVC Pl Pe, a. PIPE SHALL BE PURPLE COLORED PVC MATERIAL MEHING ASTM- Dl784, . TYPE I, GRADE I, PVC-1120 CELL CLASS 12454-B SPECIFICATIONS AS MANUFACTURCD BY BROWNLINJ; INC. OR EQUAL. b. ALL PLASTIC PIPE SHALL BE CONTfNUOUSL Y AND PERMANENTLY MARKED WITH TI.JE FOLLOWING INFORMATION, MANUFACTURER'S NAME, NOMINAL PIPE SIZ[, SCHEDULE OR CLASS, PRESSURE RATING IN PSI, NSF APPROVAL AND DAT[ OF eXTRUSION. c. A WARNING MUST BE IMPRINTED ON ALL RECLAIMeD WATJ;R PRESSURE AND NON PRESSURE SERVICE PIPES CONTINUOUSLY AND PERMANENTLY ON TWO SIDES WITH THE FOLLOWING INFORMATION IN 5/8" BLACK LETTERS, 'CAUTION, RECLAIMED WATER · DO NOT DRINK", AND "PELIGRO, AGUA IMPURA • NO BEBER'. d. PRlcSSURE LINES TO BE INSTALLED UNDERGROUND, 1. ALL PIP[ 2' AND LARGER SHALL BE CLASS 315 2. ALL Pl Pe SMALLeR THAN 2' Sf.11\LL BE SCH 40 3-FITTINGS SHALL Be SCH. 40. e. NON-PRESSURE LINES TO BE INSTALLED UNDERGROUND, 1. ALL PIPE SHALL BE CLASS 200 2. FITTINGS SHALL BE SCH. 40. INT~GRATION P L A N l60cto6 D A T t; 1st Submittal t:. liiiiiiiiiii DESIGN STUDIO LANDSCAPE ARCHITECTS 54'1 l Avenida E.ncinas, Suite 270 Carlsbad, CA 92ooa.436o t 760.602.0144 f 760.602..0388 www.lNTEGRATION¥DESIGN.com RlaVISIONS . DATE INITIAL ENGINEER Of WORt f. FITTINGS SHALL BE:AR THE Mi'.NUFACTURER'S NAME OR TRADEMARK, MATERIAL DESIGNATION, SIZE, APPLICABLE 1.P.S. SCHEDULE AND NSF APPROVAL g. ALL SOLVENT SHALL BE AS RECOMMENDED BY MANUFACTURER Ot= PIPE FITTING AND AS APPROVED. USE NO SOLVENT FROM CANS WHICH HAVE BEEN OPENED OVERNIGHT. h NO CLOS£ NIPPLES OR CROSSES SHALL BE USED. PVC NIPPLES SHALL BE BLACK IN COLOR. 2. UVR PVC PIPE AND FITTINGS [BROWNLINC OR EQUAL), a. PRESSURJ; LINE PIPJ; SHALL BE PVC mo, TYPE I GRADE I NSF APPROVED, AS MANUFACTURED BY BROWNLINE PIPE COMPANY (OR EQUAL) IN ACCORDANCE WITH ASTM D-1785 AND SHALL BE OF NOMINAL SCHEDULE 40 PIPE CLASSlrlCA TION. MATERIAL SHALL HEET ASTM D-1784, CUL CLASS 124548. , ALL PLASTIC PIPE SHALL BE CONTINUOUSLY AND PERMANENTLY MARKED WITH THE FOLLOWING INFORMATION, MANUFACTURER'S NAME, NOMINAL PIP[ SIZE, UVR-PVC TYPE AND GRADE, PRESSURE RATING IN PSI, NSF APPROVAL AND DAT[ OF EXTRUSION. c ALL FITTINGS SHALL BE UVR/PVC AS MANUFACTIJRE:D BY BROWNLINE PIPE COMPANY (OR EQUAL) PVC 1120, TYPE I, GRADE 1 NSF APPROV[D, IN ACCORDANCE WITH ASTM D-2466, SCHEDULE 40 SOCKET TYPE WITH THE DIMENSION CONFORMING TO AND INTENDED FOR USE WITH LP.S. OUTSIDE DIAMETER SCHEDULE 40 PIPE. d. ALL RISEll NIPPLES SHALL BE UYR-PVC SCHEDULE 80, PVC 1120, TYPE I, GRADE I, NSF APPROVED AS MANUi:ACTURED BY BROWNI.INE PIP[ COMPANY (OR EQUAL) IN ACCORDANCE Win-I ASTM D-1785. MATERIAL SHALL MEET ASTM D-1784 CELL CLASS 124548, THE NIPPLES SHALL Bl: 1/2' OR 3/4' I.P.S. DIMENSION WITH LENGTH AS SPECIFIED ON Pl.ANS. C. IDENTIFICATION TAPE, 1. MARKER TAPE FOR SLE[VES SHALL BE METALLIC BACKED LOCATING TAPE MARKED 'IRRIGATION" IN TWO INCH CAPITAL LETTERS EVERY THREJ; FEET ALONG THE TAPE. 2. MARKER TAPE FOR DIReCT BURIAL WIRES SH/1LL BE: RED COLORED 'ALLEN MARKING TAPE" OR APPROVED EQUAL. TAPE SHALL B[ 3' WIDE. 3. RECLAIMl,D WATER WAllNING TAPE SHALL BE PURPLE WITH BLACK LETTERING STATING, "CAUTION, RECLAIM[D WATER-DO NOT DRINK", AND 'PEUGRO, AGUA IMPURA. NO BEB[R'. TAPE SHALL BE 3 INCHES WIDE. TAPE SHALL BE AS MANUFACTURED BY EMPIRlc ENTERPRISES, INC., P.O. BOX 450, SUN PRARIE, WISCONSIN, 53590, PHONE, (608) 837-7197 OR APPROVeD EQUAL. D. SLEEVING, 1. PIPE SLEEVES Se!Al.L BE PVC SCH 80 MINIMUM. 2. WHEN ENCLOSING RECLAIMED WATER PIPING, THE PVC SLEEVE SHALL ALSO SATISFY TH[ r,EQUIREMENTS FOR RECLAIMED WATER PIPE. E VALVES, 1. REMOTJ; CONTROL VALVES AND PR!=SSURC REGULATING REMOTE CONTROL VALVES SHALL BG THE TYPl, SIZE AHD PERFORMANC[ SPECIFIED IN THE IRRIGATION LEGEND. 2. BALL VALVES SHALL BE TH[ TYPE, SIZE AND PERFORMANCE SPECIFIED IN THE IRRIGATION LEGEND. 3. CHECK VALVES SHALL BE HUNTER HCY-SERIES. 4, QUICK COUPLING VALVE'S SHALL llE Tl-<E TYPE, SIZE AND PERFORMANCE SPECIFIED IN THE IRRIGATION L[GEND. F. RECLAIMED IDENTIFICATION TAG, 1. R£CLAIMED WATER IDENTIFICATION TAGS SHALL BE WEATHERPROOF PLASTIC. 3' X 4', PURPLE IN COLOR WITH THE WORDS 'CAUTION, REC .AIMED WATER · DO NOT DRINK' IMPRINTING ON ONE SIDE, AND •PEI GRO, AGUA IMPURA. NO BESER' ON TH[ OTHER SIDE. IMPRINTING SHt .L Bt; P.RMANENT AND BLACK IN COL OR 2. REC .AIM[D WATER IDENTIFICATION TAGS AS MANUFACTURED BY T. CHl ISTY ENTERPRIS[S, 655 EAST BALL ROAD. ANAHEIM, CA 92805 (714) 771· 414, OR APPROV[D EQUAL G. VAL VE PULL BOXES, 1. RE, OTE CONTROL VALVE BOXES FOR RECI.AIM[D IRRIGATION SYSTEMS SHt .L BE MANUFACTURED BY APPUUJ ENGINErnlNG PRODUCTS (PART "101 1L2L). 2. 'BAL . VALVE BOXES FOR RECLAIMED IRRIGATION SYSTEMS SHALL BE: MAi,.UFACTURED BY APPLIED ENGINEELllNG PL10DUCTS (PART •910L1L2L). 3. PULc BOXES FOR RECLAIMED IRRIGA1I0N SYSTEMS SHALL BE MANUFACTURED BY APPLIED ENGINEERING PRODUCTS (PART •91ol1L2L). H, SPRINKLER HEADS, SPRINKLER HEADS SHALL BE OF THE TYPE, SIZE AND PERFORMANCE SPECIFIED IN THE IRRIGATION LEGEND. L RAIN SENSING DEVICES, RAIN S[NSING DEVICES SHALL BE Tl-IE TYPE SIZE AND PERFORMANCE SPECIFIED IN THE IRRIGATION LEGEND. J. CONTROL WIRING, 1. DIRJ;CT BURIAL CONTROL WIRES, ALL CONHlOL WIRES SelALL BE SOLID COPPER, 600 VOLT, TVPt UF, CONFORMING TO THE STANDARD SPEClrlCATIONS AND DRAWINGS, SPECIAL PROVISIONS AND THE FOLLOWING WIRE COLORS AND INS1ALLATION REQUIREMENTS. NEUTRAL WIRES, WHITE (•12AWG) DO NOT INTERCONNECT NEUTRAL WIRES 'BETWEEN CONTROLLERS. PILOT WIRES, ("14 AWG) [USE AS MANY AS NFCeSSARY). VALVE: NUMBE~ VAL.VE NUMBER '1' YELLOW "11· BLUE W/WHITE STRIPE "2' ORANGE '18' Rt=D W/WHITE STRIPE "3" BLUE '19" BROWN W/RED STRIP!; "4• BLACK '20" PURPLE WIRED STRIDE "5' BROWN "21' ORANGE W/WHITf STRIPE "6" PURl>LE '22' BLUE W/YELLOW STRIPE "7' YELLOW W/BLACK STRIPE "23•· BLIOWN W/YELLOW STRIPE "6' ORANGE W/BLACK STRIPE "24'' WHITE W/BLACK STRIPE '9" RED W/BLACK STRIPE "25' BLUE W/BLACK STRIPE "lOa WHITE W/R[DSTRIPE '26" BROWN W/BLACK STRIPE "11" YELLOW W/R[DSTlllPE '27" DURDL[ W/BLACK STRIPE "12" BLUE W/ReD STRIP!; "28" YsLLOW W/ORANGE STRIPE "13" ORANGE W/RED STRIPE '29" BLUE W/ORANGE STRIPE "14" PURPLE W/WHITE STRIPE '30' BROWN W/ORANGE STRIPE "15'' BROWN W /WI-UTE STRIPE "31" PURPLt; W/ORANGE STRIPE "16~ YeLLOW W/WHITE STRIPE "32'' PURPLE W/BROWN STRIPE: SPARE WIRES, RED (414 AWG) 2. SEALS FOR SPLICES AND SPARE WIRF FNDS SHALi .. BE 'SCOTCH-LOK' SEALING PACKS OR 'PEN-TITE" WIRE CONNJ;CTORS. '""' ·---------·-·- -, __ ____ ,, ________ --'--------' DATE INITIAL DATE INITIAL REVISION DESCRIPTION ----- OTHER APPROVAL CITY APPROVAL CUPOS-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. I SH~ET 11 CITY OF CARLSBAD 11 SHl~TS I LANDSCAPE IRRIGATION SPE:ClflCAT!ONS· LA COSTA LOT 1.3 RV PARKING APPROVED ,i./4~,( ~ ~~it-I • t '!.,!)"!' ASSISTANT PLANNING DIRECTOR DATE DWN BY, PROJECT NO. I DRAWING NO. CHKD BY: CUPOS-05 442-7L I RVWD BY, LQ L------------------------------------------------~::=-~--:-:::-:~=;-:-:-;:::::-;;-;:;;:::::;::-;:::::;-::;=,;:::-:::~~~:-::-;;;;;-;::;;-;;;::--;;::;;::::;----------------------------------------~-l Z:\2005 PR D ,I EC T S\DS.008 Ls, Costo RV\Drawing Filas\CD's\SPECS.dwg\lRR"SPECS {1)\9 Jan 2007 8:54 AM by: Stotion3 K. AUTOMATIC CONTROLLERS, 1. EACH CONTROLLfR SHALL BE OI= TllE TYPE, SI2£ AND PERFORMANC[ SPECIFIED IN THe IRRIGATION LEGEND, 2. CONTROLL[R SHALL OPERATe ON SINGLE PHASE, 110 TO 120 VOLT, 60 CYCLE, ALTERNATING CURRENT, 'UL" LISTED, AND SHALL CONTAIN AN ·orr· AND "ON" SWITCH TO SHUT oi=r: ENTIRE AUTOMATIC WATERING CYCLE WITJ.lOUT INTERRUPTING THE TIMING MECHANISM. OUTPUT SHALL BE 24 VOLTS AC, 3, CONTROLLrns SHALL BE ENCLOSED IN WEA THERPROor CORROSION, RESISTANT 1-lOUSING HAVING LOCKING COVER TO PROTECT ALL EQUIPMENT rROM VANDALISM. 4, CONDUIT rOR 120 VOLT ANO 24 VOLT WIRING SHALL BE AS APPROVED BY THE LOCAL BUILDING CODE eOR ELECTRICAL SERVICE AND DISTRIBUTION (PVC PIPE WILL NOT 8£ ACCEPTABLE FOR USe AS ELECTRICAL CONDUIT). L. PRESSURE REGULATION DEVICE 1 PRESSURE REGULA flON DEVICE SHALi BE HIE TYPE, SIZE AND PeRFORMANCE SPECIFIED IN THE IRRIGATION LEGEND. M. BACKl'.:LOW PREVENTION D£VICb 1. 8ACKi=LOW PREVENTION DEVICE SHALi. BE OE THE TYPE AND SIZE INDICATED ON THE PLANS. BACKFLOW PRtVENTION DEVICE SHALL MtET THE STANDARDS SET BY THL STATE OF CALIFORNIA, CALIFORNIA ADMINIS"JRATIV[ CODE, TITLE 17 . "REGULATIONS RELATING TO CROSS CONNECTIONS". 2 BACKFLOW PREVENTION DEVICE 51-JALL Be FiTTeD WITH RESILIENT SEATsD TEST COCKS, AND WITl-1 RtSILIENT SEATED SHUT-orr VALVES CAPABL!; OF ISOLATING THE DEVICE FRON THE REST 01' THE SPRINKLER SYSTEM. 9, INSTALLATION PROCEDURES: A. GEN£RAL: 1. IF NO DETAIL IS PROVIDED FOR WORK UNDER THIS CONTRACl, INSTALL IN ACCORDANCE WITI--I MANUFACTURER'S RECOMHeNDATIONS OR RECOMMENDED STANDARD PllACTICE, SUBMIT ReCOMMENDeD PROCeDURES TO OWNER'S REPRESENTATIVE BEFORE PROCfEDING WITH WORK. 2. PLANS ARE DIAGRAMMATIC AND APPROXIMATE VALVES AND OTHER IRRIGATION EQUIPMENT SHALL BE LOCATED IN PLANTING AREAS. PIPING Sf-!ALL BE LOCATfD ALONG THE INSIDE EDGES OF PLANTING AREAS EXCEPT WHERE NO I FEASIBLE TO DO SO. 3. PLANTS 24" BOX SIZE AND LARGER SHALL BE PLANTED B[FOR[ MAINLIN[S AND LA TrnAL I.INES ARE INSTALLED. 4, ALL IRRIGA"I ION APPURT[NANC[S SHALL Bt IDEN flFI [D BY PRErABRICAT[D PUllPLE EQUIPM£NT, IOGNTIFICATION TAGS, OR BY FINISHING HIE EQUIPMENT WITH PURPLE PAINT. APPROVED RECLAIMED WATER PAINTS ARe AS FOLi OWS, a. FRAZEE ARO-PLATE II ALKYD GLOSS ENAM[L. b. PROLIN[ 1000 SERIES ALKYD GLOSS ENAM[L B. WAT£R SUPPL V, t CONNECT IRRIGATION SVST[M TO POINT OF CONNECTION (POC) AT APPROXIMATE LOCATIONS SHOWN ON DRAWINGS. 2. ALLOW FOR MINOR CHANG[S AT POC CAUSED BY ACTUAL SITE CONDITIONS. 3-VERIFY AVAILABLE WATER PRESSURE AT EACH MEH,R LOCATION PRIOR TO COMMENCING CONSTRUCTION or IRRIGATION SYSTEMS. NOTIFY TflE OWNER'S RfPRESENTATIVE IMNEDIATELV IF PRESSURE IS NOT THAT WHICH IS INDICATED IN THE DRAWINGS, OR IS NOT SUFFICIENT TO OPERATE SYSTeMS AS DESIGNED. IF NOTIFICATION IS NOT PERFORMED THE CONTRACTOR SHALL ASSUME RESPONSIBlLITY FOR ANY RE=QUIRED REVISIONS. C. elf'.CTRICAL SUPPLY, 1. CONNECT POWER AND CONNECTIONS TO THe AUTOMATIC CONTROLLER AS INDICATED ON Tf-lE DRAWINGS, 2. CONTRACTOR SI-JALL COMPLY WITH APPLICABLE CODI'S AND ORDINANCES. 3-CONTRACTOR SHA LL COORDINATE WITH OWNER AND OTHER TRADES TO HAVE= POW@AVAII.ABLE TO TI--IE CONTROLLERS WHEN NEEDED. D. TRENCHING, 1. DIG TRENCHES STRAIGI--IT AND SUPPORT PIPE CONTINUOUSLY ON BOTTOM OF TRENCH. LAY PIPE TO AN EVEN GRADE;. FOLLOW LAYOUT INDICATED ON DRAWINGS. 2. DEPTH OF TRENCHES SHALL BE SUFFICIENT TO PROVIDE A MINIMUM COVER ABOVE THE TOP OF THE PIPE AS INDICAH:0 IN PIPE DEPTH SECTION UNDER THE IRRIGATION PIPE AND FITTINGS 1-JEADING, E. IRRIGATION PIPE AND FITTINGS, 1. ASSEMBLll,S, a. INSTALL NO MULTIPLE ASSEMBLIES. PROVIDE EACH ASSEMBLY WITH ITS OWN OUTLET. b. PVC TO METAL CONNECTIOts SHALL BE BY PVC MALI, THREAD ADAPTER FITTING SCREWED INTO METAL FeMALE FITTING, OR BY METAL MALE THRE/4.D ADAPTER FITTING SCREWED INTO PVC FEMALE FITTING. c. TFH.ON TAPE SHALL BE USED ON ALL TIIR[AD[D PVC TO PVC AND PVC TO MET AL JOINTS, d. REMOVE BURRS i=ROM PVC PIPE ENDS PRIOR TO CONNECTING OR SOLVeNT WELDING. USE SOLVENT MANUFACTURER'S RECOMMENDATIONS rOR CLEANING PIPE ENDS PRIOR TO MAKING SOLVENT WHDED CONNECTIONS. e. ALL PVC PRESSURE PIP£ 2" AND LARGER, SHALU-IAVE THt CORRECT SIZED CONCRFfE THRUST BLOCK INSTALLED AT EVERY ABRUPT CHANGE OF ALIGNMENT AT HALL VALVES, AT TEES, Al bl.HOWS, AND AT ENDS OF PIPE RUNS, AND Wf-!EREVER FIELD CONDITIONS OCCUR WHICH REQUIRE ONE. Rl.:i=rn TO SAN DIEGO REGIONAL STANDARD DRAWINGS W-17, W-18, AND W-19. Silt AS FOR FOUR INCH PIPE FOR THE MOST RESrnlCTIV[ SOIL CONDITION. I. IRRIGATION CIRCUITS SHALL RUN PARALLEL, OR AS CLOSE TO PARALI eL AS IS PRACTICAL, TO THE CONTOUR LINES. 2. PIPE DEPTHS, DEPTH OF PIPF SHALL BE SUFFICIENT TO PROVIDE A MINIMUM COVER ABOVE THE TOP OF THE PIPE: AS roLLOWS UNLESS INDICATED DIFFERENTLY ON DRAWINGS OR AS PER CITY OR COUNTY CODES OR REQUIREMENTS, a, COMMeRCIAL/INDUSTRIAL RtOUIREM[NTS, 1. PLANTING AREAS, NON-PRESSURE LINeS • 15" OF covrn (18" or covrn IF 'S' I.D. PIPE) PRESSURE LINES· 18" Of: COVER (24" OF COVER IF 3" 1.D. PIPE) 2. PAVED AREAS. PEDESTRIAN (SLEEVING), PIPE LESS THAN 3" IN DIAM[TcQ · 18" OF covrn PIPE 3" -51/2" IN DIAMETER· 24" or COVER PIPE 6" IN DIAMETER OR GREATER-36° OF COVER ELECTQICAI. WIRES IN SLEEVES· 36" OF COVER 3. PAVeD AREAS VEHICULAR (SLEeVING), PIPE 6" OR LtSS IN DIAMtTER · 36" OF COVER PIPE GREATER THAN 6" IN DIAMETER -18" 01' covrn 3 LINE CLEARANCE, a. PARALLEL IRRIGATION LINES SHALL NOT BE INSfALLED DIRECTLY OVER ONE ANOTHER, NOR AGAINST THE SIDES OF THE TRENCH, b. A MINIMUM TEN FOOT HORIZONTAL SePARATION or THE RECLAIMED mRIGATION WATER PIPELINE SHALL BE MAINTAINED AT ALL TIMES i=ROM A POTABLE' WATeR PIPE, SANITARY SEWER PIPE, OR STORM DRAIN PIPE, c. TJ.lE RECLAIMED WATER PIPELINE SHALL BE INSTALLGD A MINIMUM OF ONE FOOT BELOW THE POTABLE WATER PIPELINE. THE RECLAIMED WATER PIPELINE SHALL ALSO Be INSTALLED A MINIMUM OF ONE FOOT ABOVE' A SANITARY SEWER d. WHEN A POTABLE WATE:R LINE AND RECLAIMED WATER LINE CROSS, THE RECLAIMED LINE SHALL BE INSTALLED WITHIN A PROTECTIV£ SLE:EVE. THE SLEEVE SHALL EXTEND 10 FEE:T rROM EACH SIDE, FROM THE CENT.R LINE OF POTABLE LINE, roR A TOTAL OF 20 F£[T, e. RECI.AIMED WATER PIPELINE IS NOT PERMITTED IN TRENCI-JES USED FOR POTABLE WATCR OR OTHER TRADES, 4. FLUSHING AND ADJUSTING SYSTEM, a. AFTER IRRIGATION PIPRINeS AND PISERS ARE IN PLACE AND CONNECTED, AND PRIOR TO INSTALLATION OF IRRIGATION OF IRRIGATION HEADS, OPEN THE CONTROL VALVES AND USE A FULL I--IEAD OF WATER TO FLUSH OUT SYSTEM. AFTCR TI--IE SYSTEM IS THOROUGHLY FLUSl-lED, RISER SHALL BE CAPPED OFF AND THE SYSTEM PRESSURE TESTED. b. ADJUST VALVES AND ALIGNMENT AND COVERAGE OF IRRIGATIOt1 HEADS, ADJUSTMENTS MAY INCLUDE CHANGES IN NOZZLE SIZES AND DEGR£ES OF ARC. TI--IESE CHANGES SHALL BE MADE WITHOUT ADDITIONAL COST ro THE OWNER. OBTAIN COVDlAGE n=s1 APPROVAL FROM LANDSCAPE ARCHITECT PRIOR TO PLANTING OR SE[DING. c. SYSTEMS REQUIRING FLUSHING SHALL ACCOMMODATE THE WATER GeNERATED BY THE FLUSHING WITHOUT EROSION OR DISTURBANCE TO Tl.le PLANTING. WATER SHALL BE CI-IANNEL[D INTO ADJACENT DRAINAGE STRUCTURES (SWALE, GUTTER, HC) WHEAE POSSIBLE. 5. HYDROSTATIC PRESSURe TEST, a. NOTIFY OWNER'S REPRESENTATIVE 48 HRS PRIOR TO HYDROSTATIC PRESSURE TEST. TESTING SHALL OCCUR PRIOR TO BACKi=ILLING AND INST All.ATION OF ANY VALVES. b. NO H:STING SHALL OCCUR, NOR SHALL ANY WATER BE ALLOWED INTO ANY SYSTEM BEFORE THE SOLVENT MANUFAC! URER'S R[COMMENDeD CURING TIME HAS ELAPSED. c. TEST ALL PRESSURE LINES UNDER HYDROSTATIC PRESSURE OF 125 LBS PER SQUARE INCll FOR NOT LESS THAN FOUR HOURS. T[ST ALL NON-PRESSURE LINES UNDER EXISTING STA TIC PRESSURE. d. IF LEAKS DEVELOP, REPLACE JOINTS AND RLPLAT TEST UNTIL SYST[M IS PROVeN TO BE WATERTIGI-JT. e, FURNISH N[CESSARY FORCE PUMP AND OTHE:R TeST EQUIPMENT, F. I DENT I FICA TION TAPE, 1. IF PURPLE PIPE IMPRINTED WITH WARNING IS NOT INSTALLED WH£RE RECLAIMED WATER IS USED, PURPLE IDENTIFICATION TAPE, WITH BLACK LETTERING STATING, "CAUTION, RECLAIMtD WATER· DO NOT DRINK", AND "PELIGRO, AGUA IMPURA • NO BEBER" SHALL BE FASTENED TO THE TOP OF TI--IE PRESSURE SUPPLY RECLAIMED WATER PIPE, RECLAIMED WATER WARNING TAPES SHALL BE INSTALLED DIRECTLY ON TOP OF THE PIPE LONGITUDINALLY AND SHALL BE CENT@ED. THE WARNING TAPE SHALL BE INSTALLED CONTINUOUSL V FOR THE ENTIRE LENGTH OF THE PRESSURE SUPPLY PIPE AND SHALL BE FASTENED TO EACH PIPE LENGTH BY PLASTIC TAPE BANDED AROUND THE PRESSURE SUPPLY PIPE WITH FASTENERS NO MORE THAN 5 FEET APART. TAPING ATTACHED TO THE SECTIONS or PIPE BEFORE LAYING IN THE TRENCH SHALL HAVE FLAPS SUFFICIENT FOR CONTINUOUS COVERAGL 2. A SEPARATE RECLAIMED WATER WARNING TAPE SHALL BE INSTALLED TO RUN CONTINUOUSL V 12 INCI--IES ABOVE PRESSURE RECLAIMED WA Trn LINE. 3. ALL METHODS OF COLOR CODED IDENTIFICATION AND/OR TAPE DIFFEReNTIATING TI-JE PRESSURE SUPPLY RECLAIMED WATER PIPING FROM OTHER UTILITY LINES SflALL BE CONSISTENT THROUGHOU r THE SERVICE AREA. G. SLl=:£Vi=:S, 1. SLEEVES SI-JALL BE A MINIMUM OF TWO TIMES LARGER Tl-JAN PIPE OR WlllE BUNDLE IT E•ICLOSES, ONG PIP[ PER SLEEVE. PIPE SIZE SHALL BE 2" MINIMUM. 2, PIPE SLEEVE UNDeR EXISTING OR FUTURE PAVING SHALL BE INSTALLED PRIOR TO PAVING OR Rt-PAVING AND SHALL EXTEND 12" BEYOND EACH SIDE OF PAVEMENT. THE LETTE:RS "£" FOR ELECTAIC AND "W" FOR WATER SHALL BE STAMPED OR CHISELED IN THE PAVEMENT DIRECTLY ABOVE TI--IE SLEEVE ON BOTI-J SIDES or THE CROSSING, 3, SLEEVE HARKER, METALLIC BACKeD LOCATING TAPE Sl-lALL BE INSTALLED ALONG Tille ENTIRE LENGTH OF ALL SLEEVES, 12" DIRECTLY ABOVE SLEEVloS, 4, CONTRACTOR SHALL BE RESPONSIBLE FOR SLEEVES AND CHASES UNDER PAVING, THROUGH WALLS, ETC., UNLESS OTHERWISE NOTeD. s. WHEN A POTABLE WATE:R LINE AND RECLAIMED PRESSURE SUPPLY WATER LINE CROSS, THE PRESSURE SUPPLY RECLAIMED LINE SHALL BE INSTALLED WITHIN A PROTECTIVE SLEeVE. THE SLEEVE SHALL EXT£ND 10 Ff ET rROM EACH SIDG, FRON HIE CENTER LINE: or POTABLE LINE, FOR A TOTAL or: 20 i=EH. H. VALVES, 1. REMOTE CONTROL VALVES AND PRESSURE REDUCING REMOTE: CONTROL VALVES, ,. VALVES SHALL BE LOCATED IN SHRUB PLANTING AREAS WHERE POSSIBLE, b. VALVES SHALL BE GROUPED TOGETHER WHEREVER POSSIBLE AND INSTALLED IN INDIVIDUAL VAL Ve BOXES. c. REMOTE CONTROL VALVES Sl-1ALL Be OF SLOW CLOSING DESIGN, AND AUTOMATICALLY CLOSE IN TH£ EVENT OF POW£R FAILURe: d. REMOTE: CONTROL VALVES SHALL BE SIZED TO PROVIDE ADEQUA Te PRESSURE DIFFERENTIAL FOR PROPER OPERATION. e. WHERE THt PRESSURE AT TJ.lE REMOTE CONTROL VAL V[ [XCEEDS 8o P.S,I. (DUE TO EL£VATION DROPS, ETC.), A PReSSURE REDUCING VALVE SHALL BE USE:D TO REDUCE PRESSURE TO DESIGN LEVELS. f. VALVES SHALL BE: ADJUST[□ SO THAT THE MOST REMOTE SPRINKLE:R HEADS OPERATE AT THE PRESSURE RECOMMENDED BY THE HEAD MANUFACTURER. VALVE'S SHALL BE ADJUSTED SO A UNIFORM DISTRIBUTION OF WATER IS APPLl£D BY Tf-!E: SPRINKLER HEADS TO TH[ PLANTING AREAS FOR EACH INDIVIDUAL VALVE SYSTEM. g PROVIDE A PVC UNION ON THt DOWNSTREAM SIDE OF THE VAL VE, CONNECTIONS SHALL BE MADE: HORIZONTALLY, 2. BALL VALVES, a. BALL VALVES SHALL BE LOCATeD IN SHRUB PLANTING AR[AS WHeRE POSSIBLE. 5, QUICK COUPLING VALVES, a, QUICK COUPLIHG VALVES SHALL Be LOCATeD IN SHRUB PLANTING AREAS WHERe POSSIBLE:. b. QUICK COUPLING VALVES SIIALL BJ;. SH APPROXIMAT[LY 12" FROM WALKS, CURBS, HEADJ;RS, OR PAVED AREAS WI--IER[ APPLICABLE:. VERTICAL POSITIONING OF QUICK COUPLING VALVES SHALL BE SUCH THAT THE TOP OF QUICK COUPLER WILL BE 1/2" ABOVE SETTLED FINISH GRADE AS DHERMINJ;.D AFTER THE TURF IS ESTABLISH[!) AND 3" ABOVE SETTLED FINISH GRADE IN SHRUB AREAS. c, THE QUICK COUPLING VALVE SHALL BE OPERATED ONLY WITH A SPECIAL COUPLER KEY WITH AN ACME: THREAD FOR OPENING AND CLOSING THE VALVE, IN ORDER TO PREVENT UNAUTHORIZED US!;, d, THE QUICK COUPLING VALV!; COVER SI--IALL BE LOCKING TYPe · AND BE PERMANENTLY ATTACHED TO THE QUICK-COUPLING VAL VE. IT SHALL Be PURPLE RUBBER OR VINYL. I. RECLAIMED WATER IDENTli=ICATION TAG, 1. RE:CLAIMED IRRIGATION WATER VALVES OF ALL TYPES SHALL BE TAGGED WITH IDEMTIFICATION TAGS. 2. ON[ TAG SHALL BE ATTACHED TO EACH VALVE STeM DIRECTLY OR WITH PLASTIC TIE-WRAP. b. BALL VALVES SHALL BE INSTALLED TO DIVIDE THE IRRIGATION SYSTEM INTO CONTROLLABLE UNITS, AND TO AVOID DRAINING LONG RUNS or PIPING FOR SYSTEM REPAIRS, c. BALL VALVE:$ SHALL ISOLATE ALL LOOPED PORTIONS OF MAINLINE N[lWORKS. 3. CHECK VALVES, a. PROVIDE A MANUFACTURER INSTALLED CJ.lECK VALVE IN EACH SHRUB HEAD ON RISER, WHEN A MANUFACTURER INSTALLED CHECK VALVE IS NOT AVAILABLE, OR WHERE: THE SYSTEM ELEVATION CHANG!; tXCEEDS TEN FEeT, PROVIDE AN IN LINE CHECK VALVE ON THE RISER OF EACH SHRUB HEAD ACCORDING TO DETAILS. b, PROVIDE A MANUFACTURER INSTALLED CHECK VALVE IN EACH POP-UP HEAD. WHEN A MANUFACTURER INSTALLED CHECK VALVE IS NOT AVAILABLe, OR WHERE THE SYSTEM ELEVATION CHANGE EXCEEDS EIGHT FEeT, PROVIDE AN IN LINE CHECK VALVE ON THE SWING JOINT ASSEMBLY OF EACH POP-UP HE'AD ACCORDING TO DETAILS. , 4. I--IIGH FLOW SHUTOFF VALVJ;S, a. EXCESS FLOW SHUTOFF VAL \/ES SHALi. BE INSTALLJ;D WITH ALL IRRIGATION SPRAY HEADS LOCATED AT TOP OF SLOPES RE:VEGET ATED PER SECTION 7.2.3 OF TI--IE CITY OF CARLSBAD LANDSCAPE TECHNICAL MANUAL AND WITHIN TWO FEH OF A PUBLIC SIDEWALK. INTE:GRATION [:;iii iiiiiiifiiil D~SIGN STUDIO LANDSCAPE; ARCI-IITJ;;CTS 5411 Avenido l;:nclnat, Suite 270 Corl,bod, CA 920084380 t 760.602.0144 f 760.002.0386 www.lNTE:;GR'ATION-DESlGN.-n 05,008 P L A N 160ct06 J, VAL V~ / PULL BOX: 1. VALVE BOXES SHALL BE SET ONE: HALF INCH (1/2") ABOVE THe DESIGNATCD HNiSI-J GRAD!: IN LAWN AREAS AND TWO INCHES (2") ABOVE FINISI--I GRADE IN GROUNDCOVER AREAS. 2. VALVE BOXES ADJACENT TO WALKS OR PAVING SHALL NOT BE INSTALLJ;D HIGHER THAN f!NISH SURFACE OF ADJACENT WALK OR PAVING .. 3. INDICATE: ON VALVE BOX LID EITHER P.B. FOR PULL BOX, B.V. FOR BALL VALV[, OR THE IDENT!rlCATION NUMBER OF THE RE:MOTE CONTROL VALVs AND CONTROLLER CLOCK. LHTERS SHALL Bt 3' I--IIGH, 1/2" WIDE AND BURNED INTO THE LID WITH A SOLDERING IRON OR ENGRAVED INTO THE LID WITH A ROUTER. K. SPRINKLER HEADS, 1. SPRINKLER HEADS AND RISERS SHALL BE INSTALLED ACCORDING TO DH AILS. 2. SPACING OF IRRIGATION HEADS SHALL NOT EXCELD MAXIMUMS PtR HI[ lllfllGATION L[G[ND. 3 INSTALL SPRINKLeR 1--JEADS 12• rnoM ANY VERTICAL SURFACE (WALLS, FENCES, BUILDINGS, ETC.), 4. INSTALL POP-UP TYPE HEADS ADJACeNT TO WALKS, PAVING, HEADbRS, GLAZING, AND TOP OFR£TAINING WALLS TYPICALLY, 5, TOP OF POP-UP TYPE HtADS ADJACENT TO WALKS OR PAVING SHALL NOT BE HIGI-JER THAN r=INISH SURFACE OF ADJACENT WALK OR PAVING. 6. CONTRACTOR SHALL ADJUST All IRRIGATION HEADS TO FULLY COVtR ALL PLANTING AREAS AND NOT TI--IROW ONTO WALKS, BUILDINGS OR WINDOWS wHrnr=vrn POSSIBLL IRRIGATION SYSTEMS SHALL NOT SPRAY WATER ACROSS SUBDIVISION BOUNDARY LINSS. WHERE ON-SITE FIELD CONDITIONS R[QUIRE CI--IANG[S, HEADS SHAL BE ADDED OR DELETED IN ACCORDANCJ; WITH TI--IE MAXIMUM SPACING IMITS ESTABLISHeD IN THE IRRIGATION LEGEND. PIPE SIZING SI--IALL BE ~DJUSTED ACCORDINGLY. WATER VELOCITY IN PIPES SI--IALL NOT EXCEE1 5 FEET PER StCOND, AND FLOW SHALL NOT EXCEED R[COMM[NDE • NAXINUM OF RENOTJ; CONTROL VALVE SIZE. 7, IRRIGATION HEADS WITI--ILN A CIRCUIT S•·IALL HAVJ; A UNIFORM PRECIPITATION RATE. DO NOT INTGRMIX DIF'ERENT TYPES OR BRANDS OF IRRIGATION HEADS ON THE SAME CIRCUIT, L. RAIN SENSING DEVICE'S, RAIN SENSING DeVICES SHALL BE INSTALLED t :R THE HANUr=ACTUR£R'S RECOMMENDATIONS, M. CONTROL WIRING, 1, INSTALL WIRING IN SAMe TRENCH AS PReSSURE SUPPLY LINES WHEREVER POSSIBLE. 2. THERE SHALL BE EIGHTEEN INCI--IES (18") COVERAGE or= EARTH OVER THE 24-VOLT CONTDOL WIRE. INSTALL WIRE IN TRENCH AND TAPE TO MAIN LINES ON SIDE or PIPE, WHERE APPLICABLE, AT 10" INTERVALS. 3. NO SPLICES SHALL BE MADE BETWEEN CONTROLLER AND AUTOMATIC CONTROL VALVES. 4. ALL SPLICES S1-lALL BE ENCASED IN WATERPROOF CONNECTORS PfR APPROVED MATERIALS. s PROVIDE TWO SEPARATE SPARE CONTROL WIRES TO EACH SINGLE VALVE OR VALVE MANIFOLD (A VALVE MANIFOLD IS CONSIDERED ANY VALVE GROUPING WHGRE VALVES ARE PLACED NO FURTI--IER THAN 3' APART). TWO SPARE WIRES WHICH ARE LOOPED FROM VALVE TO VAL.Ve ARE NOT ACCEPTABLE, SPARE WIRE [NDS SHALL BE ENCASeD IN WATERPROOF CONNeCTORS PER APPROVED MATERIALS. 6. EACH INDIVLDUAL CONTROLLER'S CONTROL WIRES SHALL BE BUNDLED AND TAPeD TOGETHER WITH COLORED TAPE AT INTERVALS NOT EXCEEDING TEN FEET (10'). CONTROLLER IDENTIFICATION TAPE COLORS SHALL BE AS FOLLOWS, CONTROLLER A COLOR BLACK 7, TRENCH MARKfR, WHEN CONTRACTOR CANNOT INST ALL CONTROL WIRES IN TI--IE SANE TRENCH AS THE PRESSURE SUPPLY LINES, ALL DIRECT BURIAL WIRES SHALL BE MARKED WITH A CONTINUOUS RED COLORED TRENCH MARKER PLASTIC TAPE PLACED NINE INCHES (9") BELOW FINISHED GRADE DIRECTLY ABOVE THE BURIED WIRES. 8. IDENTIFY CONTROL WIRES WITH PERMANENT LABELS WHICH INDICATE THE WIRE'S CONTROLLER AND VALVE: NUMBER. ATTACH WIRE LABELS AT CONTROLLER AND BOTH SI DeS OF ANY SPLICE. 9. IN LIN£ WIRE SPLICES SHALL Be MADE ONLY IN PULL BOX[S OR VALVE BOXES. 10, ALL WIRES IN PULL BOXES SHALL BE LOOSE t<ND SHALL NOT CONE: WITHIN THREi:; INCHES (3") FROM LID. BOXES SHALL BE SIZED ACCORDINGLY TO ACCOMMODATE THIS REQUIRE:MENT. n. WIRE CONNECTIONS, NEUTRAL, PILOT AND SPARE WIReS S1-lALL BE INSTALLED WITH A 1° DIA. BY 2'•0• LONG COILED EXCESS WIRE LENGTH AT EACH END ENCLOSURE, WIRE SPLICE, AND 100' ON CENTrn. 12, TESTING, All WIRING SHALL BE TESTED FOR CONTINUITY, OPEN CIRCUITS, AND UNINTENTIONAL GROUNDS PRIOR TO CONNECTING TO EQUIPMENT. THE MINIMUM INSULATION RESISTANCE TO GROUND SHALL Bt FIFTY (50) MEGAOI--IMS, ANY WIRI IG NOT MEl':TING THIS REQUIREMENT SHALL BE REPLACED, AT THE: C( NTRACTOR'S E:XPENSE. N. BACKl=ILLING, 1. DO NOT BACKFILL THE PIPE JOINTS UNTI! TflE SYSTEM HAS BEEN PRESSURE TESTED AND ACCEPTED. 2. MECHANICALLY COMPACT BACKFILL FOR TRENCHING TO DRY DENSITY EQUIVALENT TO ADJACENT UNDISTURBED SOIL, AND MEET ADJACENT GRADES WITI-IOUT SUNKEN AREAS, HUMPS OR OTHER IRREGULARITIES. 3, PLACE 6" OR MORE OF CLtAN SOIL, i=REE OF DEBRIS, ROCK, ETC. AS INITIAL BACKFILL ON PRESSURE SUPPLY LINES. 4, PLACE FIN£ GRAMULAR MATERIAL WITI-I NO FOREIGN MATTER LARGER lHAN 1/2" IN SIZE AS INITIAL BACKFILL ON ALL NON-PRESSURE LINES, 5, PLACE A MINIMUM OF 6" OF SAND ON PIPES LOCATED UNDER AREAS WHERE PAVING WILL BE INSTALLED, USE SPECIFleD INITIAL BACKFILL rOR REMAINING J:11.L AS NECE:SSARV. 6. INSTALL PIPING UNDER EXISTING WALKS BY JETTING OR BORING. IF CUTTING OR BREAKING OF WALKS IS NEC£SSARY, IT SHALL BE DONE AND REPLACED AS A PART or THIS CONTRACT. OBTAIN PERMISSION rnoM OWNSR'S REPRESENTATIVE BEFORE PROCEEDING. 0. AUTOMATIC CONTROLLE~S, 1. TI-JE AUTOMATIC CONTROLLER SHALL BE INSTALLED AT THE APPROXIMATE LOCATION SHOWN ON THE PLAN Its A HANNER RECOMMENDED BY THE MANUFACTURER. CONTRACTOR SHALL CONNECT REMOTE CONTROL VALVES TO CONTROLLER TO CORRESPOND WITH THE STATION NUMBERS, IN THE SEQUENCE SHOWN ON THE PLANS. 2. EACH AUTOMATIC CONTROLLER AND ITS ASSOCIATED EQUIPMEN r SHALL BE IDENTIFIED WITH A SIGN BEARING THE WORDS "RECLAIMED WATER USED FOR IRRIGATION" IN ENGLIS!--1 & SPANISH WITH BLACK LETTERS 1 INCH HIGH ON A PURPLE BACKGROUND. THE SIGN SHALL BE PLACED SO THAT IT CAN BE READILY SJ;EN BY ANY OPERATIONS PERSONNEL, UTILIZING THE EQUIPMENT. 3, CONTROLLERS SHALL BE PROGRAMMED SO WATERING WILL NOT INT[RFERE WITH CONSTRUCTION OR NORMAL USE OF THE: PROPERTY. 4, ALL LOCAL AND OTHER APPLICABLE CODES SHALL TAKE PRECEDENCE IN CONNECTION OF THE no VOLT ELE:CTRICAL SERVICE TO THE CONTROLLER. OWNER SHALL PROVIDE POWER TO THE CONTROLLER. CONTRACTOR SHALL COMPLETE HOOK-UP TO THE CONTROLLER, 5, CONTROL MECHANISMS FOR MOISTURE SENSING SYSTEMS SHALL BE ACCOMMODATED WITHIN THE CONTROLLER eNCLOSURE. 6. UNLESS SPeCIFICALL Y APPROVED BY THE PLANNING DIRECTOR, ALL CONTROL CIRCUITS SHALL BE DESIGNED TO OPERA TE ONE VALVE AT A TIME. P. PRJ'.'SSURE R£GULATION D£VICJ'.'S, 1. PRESSl,IRe RE:GULATION DEVIC£S SI-JALL BE INSTALLED ON ANY SYSTEMS WITH A STATIC INLET PRESSURE AT THE POINT OF CONNECTION GREATER THAN 80 PSI UNLESS SPECIFICALLY APPROVED BY THE PLANNING DIReCTOR. PRESSURE SHALL BE ReGULATED TO A PRESSURE ADEQUAT[ TO OPERATE THE EQUIPMENT AT DESIGNED PRESSUPES WITH ALL INCIDENTAL AND LINE LOSSES INCLUDED. 2. PRESSURE REGULATION DEVICES SHALL BE INSTALLeD ABOVE GROUND, IN LINE WITH THE BACKi=LOW PREVENTION DEVICE, MAKING ON£ COMPLETE ASSEMBL V. 3, ADJUST PRESSURE REGULATION DEVICES TO ACHIEVE 10 PSI MORE THAN THE MINIMUM HEAD OPERATION PRESSURE FOR EACH TYPE OF HEAD AT THE HIGHEST SYSTEM AND/OR HIGHeST AND LARGEST SYSTEM. SEE IRRIGATION LE:GEND FOR THE LOWEST OPERATING PRESSURE RANGE OF EACH HEAD TYPE. Q. BACKf'LOW PRf;VENTION UNITS: 1. BACKFLOW PREVENTER ASSEMBLIES SERVING RECLAIMED WATi::R SHALL BE PAINTED PURPLE AND BE LOCATED IN SHRUB AREAS. FINAL LOCATION SHALL BE APPROVED BY OWN!;R'S RePRESENTATIVE PRIOR TO INSTALLATION. R. CLEAN-UP, 1. UPON COMPLCTION OF WORK IN THIS SECTION, CONTRACTOR SHALL REMOVE: ALL RUBBIS!--1, TRASH, AND DEBRIS RESULTING FROM THe OPERATIONS, RENOVe UNUSED EQUIPMENT AND IMPLEMENTS OI= SERVICE: LEAVE ENTIRE AREA INVOLVED IN A NEAT AND ACCEPTABLE CONDITION SUCH AS TO MEET THE APPROVAL OF THE OWNeR'S REPREStNTATIVE, CUP05-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. D A T E lS.l Submittal ti---==--==-1-t=--==--1--t=--==--==--==--==--==--==--==-------=--==--==--__ ··=··=·-==·====!========~===:[][I I CITY OF CARLSBAD-]~ REVISIONS LANDSCAPE: IRRIGATION SPfCIFICATIONS: l-----+------1-------------------~----------+----+---+-----i DATE INITIAL DATE INITIAL DATE IHITIAL ENGINEER Of WORt REVISION DESCRIPTION OTHF.R APPROVAL CITY APPROVAL LA COST A LOT 1.3 RV PARKING DWN BY: ___ _ CHKD BY; ___ _ RVWO BY, PROJECT NO, CUP05-05 -0 ' -~----------------------------------------------------------------,------..,.--------.,.----------------------------------------------------------------___J--' Z.\200~ P R O J C r. T S\05.008 1.0 Costa RV\Dniw1ng Fl!e~\CD s\SPfCS.dwg\!RR-SPECS (2)\9 Jan 2007 8.54 AM by. Slnt,MJ . SLOPE PLANTING REQUIREMENTS SLOPES 6,1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ON• OR MORE OF THE FOLLOWING PLANTING STANDARDS, a. ST AND ARD "l · COVER CROP/REINFORCED STRAW MATTING covrn CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES. CLOVERS. AND/OR WILD FLOWERS. SUBMIT THE SPECIFIC SoED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT THE RAT• AND MANNER SUFFIQENT TO PROVlDE 90% COVERAGE WITHIN THIRTY (30) DAYS. TYPE OF REINFORCED STRAW MA mNG SHALL BE AS APPROVED BY THI; CITY AND STAKI;D TO Tl-IE SLOPE AS RECOMMENDED BY THE MANUFACTURER. REINFORCED STRAW MATTING SHALL Bo REQUIRED WHoN PLANTING OCCURS BETWEEN AUGUST15 AND APRIL 15. b. STANDARD•2-GROUNDCOVoR ONE HUNDRED 000%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCoLLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLA TToD MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE VEARJ c. STANDARD •3-LOW SHRUBS LOW SPREADING SHRUBS (PLANTED FROM A MINIMUM OF 2a' LINERS) SHALL COVER A MINIMUM OF SoVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZi;). d. STANDARD •4-TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS) AT A MINIMUM RAH; OF ONE (I) PER TWO HUNDRED (200) SQARE FEET SLOPES-&1 OR STEEPER AND, u. 3' OR LESS IN VERTICAL HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT MINIMUM STANDARD •1 b. 3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARDS "l, •2, AND •3. e. IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARDS•l, "2, •3, AND•4. AReAS GRADED FLA TIER THAN 6,1 REQUIRE ST AN DARO •1 (COVER CROP) WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS, a. SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. b. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITV c. IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO Tl-IE PUBLIC OR 1-!AVE SPECIAL CONDITIONS Tl-IA T WARRANT IMMEDIATE TREATMENT. 1 NOT!; 1. ALL TREES WITHIN 10' OF ANY IMPROVEMENT SUCH AS A WALK, WALL, CURB, ETC SHALL BE INST ALL£D WITH ROOT BARRIERS -SEE SPECIFICATIONS FOR TYPE AND SEE DETAIL C/ SHEET 13. ROOT BARRIERS SHALL RUN ALONG THE CURB AND SIDE WALK FOR A MINIMUM OF 5' IN EITHER DIRECTION FOR A TOTAL OF 10 LINEAR FEET MINIMUM INTEGRATION ~ iiiiiiiiiiliiil DESIGN STUDIO LANDSCAPE: ARCHIT1=CTS 5411 Avenido ~ncina5,Svile 270 Carlsbad, CA 9.2008.4380 t 760.602D144 f 760.602.0388 ,,,,_JNTEGRATION•DESIGN.com p L A N D A T i;: 160cto6 1st Submittal R E: V I s I 0 N s 7 Deco6 2nd Submittal 19Deco6 3rd Submittol 10Jano7 Pna! Submittal DATE ENGINEER TRE:E: LE:GE:ND SYMBOL SIZE 24" Box 24' Box QTY. 7 9 11 VINE/ESPALIER LEGEND SYMBOL 0 • 1 Gal, 5Gal. HVDROSEED LEGEND SPECIES Bromus hordeceus T rifolrum hirtum 'l-lykon' Vvlpia Myuroa Vas. l-lirauta QTY. 12 24 BOTANICAL NAME Pinus holepensis Platanus rocem06Cl Quarcus virginiana BOTANICAL NAM!, Ficvs pumila Solandra maxima COMMON NAME Biondo Brome l-lykan Qose Clover Zorro Annual Fescue • MIN.% PLS {PURE LIVE SEED) • SEED PURITY x GERMINATION RA TE LBS/ ACRE 24.00 10.00 6.00 40.00 COMMON NAME Aleppo Pine California Sycomore Southern Live Oak COMMON NAM!; Creeping Fig Cop of Geld Vine MIN.%PLS' 90 90 85 REMARKS X X X REMARKS X X SPECIFICATIONS (Ht X Width) X'xX' X'xX' X'xX' SPECIFICATIONS (1-!t. X Width) X'xX' X'xX' CUPOS-03 Minimum Planting Specifications si;i; SHJ;;E;T 13 FOR PLANTING DETAILS SEE; SHEtT 14 FOR PLANTING SPECIFICATIONS ----------· -------------·----- ------------------------- - --- -----------· INITIAL DATE INITIAL OF WORi REVISION DESCRIPTION OTHER APPROVAL 1. CONTRACTOR SHALL PROVIDE AN AGRICULTURAL SUITABILllY TEST REPORT FOR ON sm; SOIL AND ON srn; TOPSOIL a.THE CONTRACT SI-IALL SUBMIT A REPORT TO THE OWNER'S REPRESENTATIVE AND THE CITY OF CARLSBAD INSPECTORPRIOR TO ORDERING SOIL AMENDMENTS OR PLANT MATERIALS. b. TAKE2SAMPLESOFSITE:SOILAT A DEPTI-I OF6'TO 12", WITI-IIN PROPOSED PLANTING AREAS. AFTER COMPLETION OF GRADING AND PRIOR TO WEED CONTROL AND SOIL PREPERATION e. SUBMIT SAMPLES TO 'SOIL AND PLANT LABORATORY', 1594 NORTH MAIN STRtET, ORANGE, CA, 9'11,67, FOR SOIL EVALUATION. d. REQUEST TESTING FOR AGRICULTURAL FERTITUTY AND SUITABILITY (TEST NO. A-05) WITH WRITTEN RECOMfNDATIONS FOR SOILS AMENDMENT. HVDROSPRAV, SOD LAWN, SEED LAWN.ACID LOVING PLANTS, AND POST MAINTENANCE FERTILIZATION PROGRAMS. •-SUBMIT COPIES OF THE: REPORT TO THE LANDSCAPE ARCHITECT, THE OWNER'S REPRESENTATIVE, AND THE CITY OF CARLSBAD INSPECTOR. f. SOILS REPORT RECOMMENDATIONS SHALL TAKE PRECEDENCE OVER THE AMENDMENT AND FERTILIZER RATES SPECIFIED IN THESE PLANS. 2. FINISH GRADING, o. PRIOR TO THE COMMENCEMENT OF PLANTING OPERATIONS. COMPLETE FINISH GRADING AS SPECIFIED. b. WHEN PRELIMINARY GRADING, INCLUDING WEEDING AND FERTILIZING I-IAS BEEN COMPLETED, AND Tl-IE SOIL HAS DRIED SUFFICIENTL V TO BE READILY WORKED, PLANTING AREAS SHALL BE GRADED TO UNIFORM LEVELS OR SLOPES AT A MINIMUM OF 2%. MINOR ADJUSTMENTS TO FINISH GRADES SHALL BE MADE IN THE DIRECTION OF THE FLOW. LOW SPOTS AND POCKETS SHALL BE GRADED TO DRAIN PROPERLY. GRADING SHALL BE DONE WHEN SOIL IS AT OPTIMUM MOISTURE CONTENT FOR WORKING. ROCK AND DEBRIS MORE THAN r IN DIAMETER SHALL BE REMOVED FROM THE SITE. c. LAWN BEDS SHALL BE RACKED LIGHTLY TO AN EVEN SURFACE, REMOVING ANY FORIEGN MA TE RIALS. CARE SI-IALL BE TAKEN NOT TO CHANGE THE DRAINAGJ; PA TTJ;RN. THE LAWN BED SHALL BE INSPECTED BY THE OWNER,5 REPRESENTATIVE TO DETERMINE THE SUITABILITY FOR PLANTING PRIOR TO INSTILA TION OF SEED OR SOD. 3. THE CONTRACTOR SHALL SUBMIT TO THE OWNE:R'S REPRESENTATIVE AND THE CITY OF CARLSBAD INSPECTOR THE FOLLOWING ITEMS, a. SUBMIT A SAMPLE OF THE PROPOSED BARK MULCH. b. SUBMIT A SAMPLE 01' THE PROPOSED ROOT BARRIER. APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ~ er] CITY OF CARLSBAD l PLANNING DEPARTMENT 4 LANDSCAPE: TR[[ PLANTING P/_ANS: LA COSTA LOT 1.3 RV PARKING ... ··--" -. -----· -· ------·---·----- APPROVED 1~-l 6r, ~~ 1-tGt-~ j PLANNING DATE -·--- ---------····-· --------DWN BY, PROJECT NO. DRAWING NO. DATE INITIAL CHKD BY, CUPOS-03 442-7L RVWD BY: CITY APPROVAL ,- ' 0. 0 10 20 40 North Arrow Project·-····•··•·····-··········· o5.008 1-L-------------------------------------------------------:;-::-::;:::::-::-;:-::--:-:,-::-:-;:-::::-::;::-;:-=-;;;:-;:=-;::::;===~;-::--::~;;-;:;-;-;:;--=-:;=;-------------------------------------------~ ....J Z:\2005 P R O J E C T S\05.008 lo Costo Rv\Drowing Filw\CD's\PLTGT,d...,g\LTP-1\9 Jon 2007 8:51 AM by: $tct1onJ ~~-:)\ < / ' C i.· ·If I:, l i.' :ti/fl;[ CONT~ACfOR TO INSTALL (2) ROSeMARINUS O~FICINALIS 'LOCKWOOD DE: FOREST' IN E:AC ··CELL OF THE PLANTABL£WALL INTEGRATION l:.il liiiiiiiiiil DE;SIGN STUDIO LANDSCAPE ARCHITECTS 5411 Avenido ~inas, Suite 270 Carlsbad, CA 92008.4380 t 76o..602.01-44 f 760.JS02.0386 --,.INTE:GRATION~DE:SIGN.cam p L A N D A T E 160cto6 1st Submittal R E V I s I 0 N s 7Deco6 2nd Submittal 19Deco6 3rd Submittal 10Ja:no1 Final Submittal SI-IRUB LEGEND SYMBOL SIZE QTY. • lGal. 129 @ 5Gal. 51 BOTANICAL NAME COMMON NAME: Agapanthus afrieonvs LIiy-Of-The-Niie ti..rbutw unedo 'Compada' Strawberry Tree REMARKS SPECl~ICATIONS (1-lt. X Width) 12" X 6" 14•, 10· CUPOS-03 ® 5Gal. 34 3ougainv1Ueo 'Rosenka' No Common Nome 14•x 14• ~ 41 Pots. 18"0.C. Carex T umulicola X'xX' © !Gal. 80 ::i&tiJs 'Sun.set' Rockrose CD 5Gal. 38 _eonoti.s leonurus lion's Tail 18' X 16' @) 5Gal. 43 ;>hormium tenax 'Dork Delight' New Zealand Flax ® 5Gal. 37 Pittosporum tobiro Tobiro @ 1 Gal. 109 Rhaphlolepi• lndiea 'Clara' Indio Howthom 12"x 10" 5Gal. 18 E:ribotrya deflexc 'Copperlone' NCN 18' X 16" 12" O.C. Rosmarlnus officlnalis 'Lockwood de !=orest' Rosemary 5Gal. -45 Rosmarin us officinalis 'Tuscan Blue' Rosemary 5Gal. 163 Trachelospermumjasminoides Star Jasmine Shrub Funn 10' X 10" J5Gal. 64 Viburnum japonieom NCN 18"' X 16" NOTES, 1. ALL PLANT MAT[RIAL DESIGNAT~D WITH(•••) SHALL B[ PLANT[D WITH THE ACID LOVING PLANT BACK FILL MIX (S[[ PLANTING SP~CIFICATIONS) SEE SHEET13 FOR PLANTING DETAILS S[E SH[[T 14 FOR PLANTING SPE:CIFICA TIONS ------ ---- ----- DATE INITIAL DATE INIT!AL DATE INITIAL REVISII •N DESCRIPTION -··-~ ENGINEER OF WORt OTHER APPROVAL CITY APPROVAL APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ~ CITY OF CARLSBAD I SHl~TS I 2 PLANNING DEPARTMENT LANDSCAPE: SHRUB PLANTING PLANS: LA COSTA LOT 1.3 RV PARKING -· . -----. -·-·-----· APPROVED 11~!.,{ tr-~~ /·1.:i-0-r PLANNING DATE . -----------· - OWN BY, PROJECT NO. DRAWING NO. CHKD BY: CUP05-03 442-7L RVWD BY: "'7 0.. 0 10 20 40 North Arrow Project. ............. --·-·· .. ···.... OS.008 (/) ! '--------------------------------------------------------------------,---------.-----,----,-,---,--,----------------------------------------------------------~J Z:\2005 P R O J EC T S\05.008 La Cmit□ Rl..'\Drowing Files\CO's\PLTGS.dwg\LSP~1\9 Jen 2007 8:50 AM by: Sfotion.3 j l ~~~~:U-----------12 -II illliiillliii11 11 l:" -'"" 'j!Iltrr1 I iJJrnll! ccj·· · ··· . -~!IL ... i ;_; {rfLrn-·n III St:;CTION ( WIND III LEGGND [II LODGE POLE ST AKE (SeE PLANTING SPtCIFICATIONS). PLACE AT OUTSIDE EDGt OF ROOTBALL TOP OF ST AKE SHALL NOT eXTEND INTO CROWN OF TREE II] BLACK PLASTIC CINCH-Tis$ WITH ONE TWIST NAIL TO STAKES W/ GALVINIZ&:D ROOFING NAIL WRAP LOOSsLV TO TREt . III LA vi;R OF MULCH (SEE PLANTING SPE;CIFICATIONS FOR DsPTH) KsEP MULCH3" AWAY FORM BASE;OF TRJ::ES 5 GAL. AND SMALLeR, 6" AWA V FROM BASE OF TREES 15 GAL. AND LARGER (1] ROOTBALL (SEE PLANS FOR CONTAINER SIZE;) []) FERTILIZER TABLETS PER SPECIFICATIONS III AMENDED BACKFILL III PLACE ROOTBALL oN NA T1vi; susGRADE III WIDTH EQUALS TWICE THE CONTAINtR DIAM.TeR (I] KEEP CROWN 1" -2• ABOVe FINISH GRADE li§j WATeR BASIN (6" HelGI-ID [jj] FINISH GRADE NOTE, • IMAGINARY LINE BETWEeN STAKeS & TREE SHALL BE PARALLEL TO PREVAILING WIND DIRECTION ~ --~-T2 E_E_ST_A_K_I N_G_(-'--D_O_U_BL_E_,__) --@ LEGEND [II SHRUB. si;i; PLANTING LeGEND [TI KEEP CROWN l" ABOVE FINISH GRADE m LA VsR OF MULCH (SEs PLANTING SPECIFICATIONS FOR D6PTH) K6EP MULCH 3" AWAY FROM BASE OF SHRUBS 5 GAL. & SMALL6R I l;;c m +--I~ alllr,~;;. ,;..;;,;..If, '"""""' -,, I-_ 5 (1] FINISH GRADE III m AMENDED BACKFILL 7 III FE;RTILIZER PACKITS (SEE PLANTING SPECIFICATIONS) ·-· -,cTIL-m- . -0iTr-Tl=f -.. = III PLACE ROOTBALL ON NATIVE SUBGRADE (SEE PLANTING III SPECIFICATIONS) III WIDTH EQUALS TWIC&: TH&: CONTAIN&:R SIZ&: 02' MIN, FOR LINERS) (I] CONTAINER DEPTH 02' MIN. FOR LINERS) SECTION ~ -B~-LTR_U_B_P_L_AN_T_I_N_G ____ ® _NO_T_AS_S_IG_N_E_D _____ CD SECTION LEGEND [II RUBBER GARDEN HOSE [Ij 12 GA. GALV. WIRE (NOT TO BE SPLICED) 3/8" OR 5/16" O.D. X /062 WT. POL V.TI-IE:LENE TUBING BY WARD MANUFACTURING (714) 631-5055 [I) KEEP CROWN l' -2" ABOVE FINISH GRADE G) LA VER OF MULCH (SEE PLANTING SPECIFICATIONS FOR DtPTH) KEtP MULCH3" AWAY FORMBAStOF TRtES 5 GAL. AND SMALLER, 6" AWA V FROM BASE OF TREES 15 GAL. AND LARGrn []) ROOTBALL, SEE PLAN FOR CONTAINER SIZE III FERTILIZER PACKETS PER SPECIFICATIONS Tllli<~~ 7 III 2" X -4• X 3'-0" LONG RWD. DEADMEN Jmffl'i1:'Jjru;;;;.7 8 [fil AMENDED BACKFILL (I] WIDTH EQUALS TWICE THE CONTAINtR DIAMETER li§j PLACE ROOTBALL ON NATIVE SUBGRADE [jj] WAT6R BASIN (6" HEIGI-H) @] FINISH GRADE ~ -~-UVE_E_G_U_Y_IN_G _____ ® 0. >-I-• --0 • '<t • Ii --0 >-1- SE;CTION/E;LEVATION 2 LEGEND [II GALVANIZED EVE BOLT. BOL TINTO WALL [TI WALL BEYOND @) 12 GAUGE WIRE• SECURE TO EVE BOLT. (1] FINISH GRADE []) VINE ROOT BALL III SOIL ~ -~-nN_E_A_T_TA_C_~_M_E_N_T ____ ® "OSCAP ~ ~ ..J .... s gn ture 31 D c07 ' ,w INTEGRATION ~iiiiiiiliii Dl:SIGN STUD 10 LANDSCAPE ARCHITtCTS 5411 Avenido Encino$, Suite 270 Carlabad, CA 92008.4380 t 760.602..0144 r 760.602.0388 www.l NTE;GRATION•0ESIGN.QJITI 2 3 4 St:;CTION 0~ W-rfi';_O"O 0 ' 0 LEGEND [II FINISH GRAD!; [TI WATSR BASIN m AME IDED BACKFILL MIX AS REOURED G) PLAC~ ROOTBALL ON NATI Vo GRAc•E []) ROO BALL, SEE PLAN FOR CON"'AINER SIZE III MUL• .:fl IF REQUIRED, S!;E DLA~ flNGSPECIFICATIONS III CURI ORPAVING III FERTILIZER TABS, SEE PLANTING INSTRUCTIONS (I] ROOT BARRIER W/ GRAVEL BACKFILL, SEE; PLANTING SPECIFICATIONS FOR TYPE: AND SIZE. ROOT BARRIER SHALL BE LOCATED PARALLEL TO ALL PAVING SURFACES li§j AMENDI;D BACKFILL MIX [jj] WIDTH EQUALS TWICE THE CONTAINER DIAMETER _N_O_T_A_SS_IG_N_!;:_D _____ @ p L A N D A T E l60ct06 1st Submittal R E V I s I 0 N s ------ 7Deco6 2nd Submittal 19Dec06 3rd Submittal 10Jano7 Final Submittal DATE INITIAL ENGINEER Of WORI REVISION DESCRIPTION ·o· TRIANGULAR PLANT SPACING CI-IART # OF PLANTS= SF/("D") X 'A' SPACING"D• ROW"A' •OF PLANTS DISTANCE DISTANCE PoRS.F. B6TWEEN B.TWEEN TRIANGULAR PLANTS l!OWS SPACING 6"0.C. 5.20'0.C. 4.6154 8"0.C. 6.93"0.C. 2.597-4 10·0.c. 8.66"0.C. 1.6628 12" o.c. 10.40'0.C. 1.1558 15"0.C. 13.00"0.C. 0.7365 18"0.C 15.60'0.C. 0.5128 24"0.C. 20.80"0.C. 0.2885 30"0.C. 26.00"0.C. 0.1846 36"0.C. 30.00"0.C. 0.1333 42"0.C. 36.37" o.c. 0.0943 4'0.C. 3.46'0.C. 0.0723 5'0.C. 4.33'0.C. 0.0462 6'0.C. 5.20'0.C. 0.0321 8'0.C. 6.95'0.C. 0.0180 10'0.C. 8.66'0.C. 0.0115 12'0.C. 10.40'0.C. 0.0080 15'0.C. 13.00'0.C. 0.0051 20'0.C. 17.30' o.c. 0.0029 25'0.C. 21.65'0.C. 0.0018 30'0.C. 26.00'0.C. 0.0013 CUPOS-03 ~ -B~-PAR_U_B_P_L_A_NT_SP_A_C_E ___ ® _N_O_T_A_SS_IG_Nt_D _____ @ ----- ---~---- DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. ~ CITY OF CARLSBAD [ SH]~TSJ 3 PLANNING DEPARTMENT LANDSCAPE PLANTING DETAILS: LA COSTA LOT l.3 RV PARKING -------I APPROVED 11.J:( tr-~;A! I-\"i. C'1 I PLANNING DATE DWH BV: PROJECT NO. DRAWING NO. CHKD BY: CUPOS-03 442-7L RVWD BV, . - ('I i I . a.! '------------------------------------------------------------------,------,-----------,--,-----------------------------------------------------------'~-Z:\2005 P R O J E C T S\05.008 La Cost.a RV\Ornwing fi!es\CD's\PDETS.dwg\SHT-27\9 Jon 2007 8:50 AM by; Stolkm3 D. STATEMENTS oi: CONFIRMATION, LANDSCAPE PLANTING SPECIFICATIONS THE CONTQACTOR SHALL SUBMIT TO THE OWNER'S REPRESENTATIVE, THE FOLLOWING ITEMS, SCOPE, PROVIDE LABOR, MATrnlALS, TOOLS, PERMITS, TAXES AND ALL OTll[R COSTS CONSJDERED AS NEC!:SSARV TO COMPLETE PLANTING WORK AS INDICATED AND SPECIFIED WITHIN THESE PLANS BY INTEGRATION DESIGN STUDIO. THE INSTALLATION SHALL BE COMPLETE IN [VERY RESPECT TO THE SATISFACTION OF THE OWNl'R. GENERAL CONDITIONS, A. HJE CONTl!ACTOR SHALL BE LICENSED OR CGRTIFIED BY THt STATE OF CALIFORNIA, FOR THE TYPE OF WORK SHOWN ON THE PLANS. B. ThE CONTRACTOR SHALL CARRY ALL NtCESSARY COMPENSATION AND LIABILITY INSUIIANCE TO covrn 1-115 WORK[RS AND INSTALLATION so AS TO OFFrn i:LJLL PROTECTION TO THE OWNER FROM ANY POSSIBLE llAMAG[ SUIT OR Ll[N ON TII[ OWN[R'S PROPERTY. C. I. OCAL, MUNICIPAL AND STAT[ CODES, LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY MADC A PART OF THtSE PLANS AND SPECIFICATIONS. D rnr: Pl.ANTING D[SIGN AS INDICATED ON THE PLANS IS DIAGRAMMATIC. SCALED DIMENSIONS AR[ APPROXIMAT[. vrnu:y ALL SITE Dlr,J[NSIONS PRIOR TO PROCEEDING WITl-1 TH[ WORK. E. DO NOT PRocr:rn WITH ANY WORK Sl-10ULD HJERE BE ANY UNKNOWN OBSTRUCTIONS, GRAD• DIFFERENCES OR DISCREPANCIES FOUND ON Tl-lE SITE OR ANY DISCR[PANClsS WITHIN TH[ PLANS. IMMsDIATfL y BRING DISCREPANCIES TO THE AllENllON OF THE OWN£R'S REPRESENTATIVE. IF NOTIFICATION IS NOT PERFORMED THC CONTRACTOR SHALL ASSUME FULL RsSPONSIBILITY FOR NEC[SSARY REVISIONS. E. THE CONTRACTOR SHAU. NOTE ALL EXISTING FINISH GRAD[$ PRIOR TO COMM[NCING WORK. RESTORE FINISH GRADES CHANGED DURING THF COURS[ OF THE WORK TO ORIGINAL CONTOURS OR INTENDED CONTOURS WHERE PnACTICAL. G. Tl-1E INSTRUCTIONS TO BIDDrns. FROM INT[GRATION D[S!GN STUDIO. SHALL BE COMPLETED AND RETURNED TO THE OWNER'S REPRESENTATIVE WITH THE BID BY THE CONTRACTOR AND SHALL BE A PART OF TH&:SE PLANS. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ABS£NCE OF INSTRUCTION TO BIDDERS. H. UPON A WARD OF TH[ CONTRACT. THE CONTRACTOR SHALL IMMEDIATELY LOCATE, ORDER AND PURCHASE, Oil HAVF HELD. ALI SPFCIFIEI) PLANT MATERIAL fXCLUDING PRE-SCL[CTED PLANT MATERIAL. L THE SITE SHALL BE KEPT CLEAN AND FREE OF EXCCSS EQUIP~IENT, MATERIALS, AND RUBBISH INCIDENTAL TO THE WORK DURING THE CONSTRUCTION AND MAINTENANCE PERIOD. J. THE OWNEQ'S REPRESENTATIVE SI-IALL HAVE THE RIGHT TO MAKE MINOR CHANGES IN THG PLANTING DCSIGN AND INSTALLATION AT NO ADDITIONAL CHARGE. K. PRIOR TO EXCAVATION FOR PLANTIMG, OR PLACING OF STAKES, LOCATE UTILITIES, ELGCTRIC CABLES. CONDUITS, SPRINKLER LINES, HEADS, VALVES. AND VALYb CONTROL WIRES. SO TIIAT PROPrn PRECAUTIONS MAY Bf TAKEN NOT TO DAMAGE SUCH IMPROVfMENTS. IN THE EVENT OF A CONFLICT BETWl'EN SUCH LINES AMD PLANT LOCATIONS, PROMPTLY NOTIFY Tl-lf LAMDSCAPE ARCHITECT TO ARRANGE FOR RfLOCATION OF ONb OR THb OTl-1ER. FAIi.URE TO FOLLOW Tl.TIS PROC[DUR[ PLACES THE RESPONSIBILITY ON THE CONTRACTOR FOR MAKING REPAIRS AT HIS EXPENSE FOR DAMAGES RESULTING ;:ROM WORK HEREUNDER. L NOTIFY LANDSCAPE ARCHITECT IN WRITING OF SOIL OR DRAINAG[ CONDITIONS ENCOUNTERED DURING PLANTING OPERATIONS WHICH Arif DETRIMENTAL TO GROWTH OF PLANT MATERIAL. SUBMITT ALS, A. SOII.S AMAL VSIS: 1. AGRICULTURAL SUITABILITY TEST REPORT FOR ON SITE SOIL AND ON SITE TOPSOIL. a. !HE CONlllACIOll SHALL SUBMIT A REPORT TO TH[ OWrJGR'S REPRESENTATIVE PRIOR TO ORDERING SOIL AMfNDMsNTS OR PLANT MATEIIIAI.S. b TAKE 2 SAMPLES OF SITE SOIL AT A DEPTH OF 6" TO 12•. WITHIN PROPOSED PLANTING AREAS. AFTER COMPLETION OF GRADING AND PRIOR TO WEED CONmo1. AND SOIi. PREPARATION. c. SIJHMIT SAMPLES TO 'SOIL AND PLANT LABORATORY', 1094 NORTH MAIN STREET. ORANGE, CA. 92667, FOR SOIL EVALUATION. d. RliQUEST TESTING FOR AGRICULTURAL FERTILITY AND SUITABILITY (TbST NO. A-05) WITH WlllTTEN RECOMM[NDA TIONS roR SOILS AMGNDM(NT, HYDROSPRAY. SOD LAWN. SEED LAWN. ACID LOVING PLANTS, AND POST-MAINTENANCE FERTILIZATION PROGRAMS. •· SUBMIT COPIES OF TH£ REPORT TO THE LANDSCAPE ARCHITECT AND OWNlR'S REPRESENTATIVE. f SOILS R[PORT RECOMMENDATIONS SHALL TAKE PR(C(DENCE OVER THG AMENDMENT AND FEIHILIZER RATES SPECIFIED IN THESE PLANS. B. PLAHT MATERIALS, I. SUBMIT 3"X5" OR 4"X6° COLOR PRINT PHOTOGRAPHS 90 DAYS PRIOR TO INSTALLATION TO THG LANDSCAPE ARCHITECT AND OWNER'S REPRESENTATIVE OF EACII SPECIFIED TREE, SHRUB. AND GROUNDCOVER TAKEN AT THelR SOURCES FOR APPROVAL. THE PHOTOS SHALL BE OF THE PLAN.I MATERIAL TO BE DELIVERED TO THE JOBSITE. ALL PLANT MATERIAL . Dll:tJVEREO SHALL BF OF EQUAL OR BETTER QUALITY AS TH£ PHOTO GIVEN AS A REPRESENTATIVE SAMPLE. 2. IF ANY PLANT MATERIAL SPECIFIED IS NOT OBTAINABLE, SUBMIT A WRITTEN SUBSTITUTION REQUEST TO THE LANDSCAPE ARCHITECT DURING THE BIDDING PcRIOD. C. WRITTEN GUARANTEE, 1. ALL Tl>EES SHALL BE GUARANTEeD, IN WRITING. TO LIVE IN A HEALTI-N CONDITION FOR 1 VEAR FOLLOWING THE DATE OF COMPLETION OF THE SPECIFIED MAINTENANCE PsRIOD. THIS DATE SHALL BE DtTERMINfD BY TH[ OWNER'S REPRESENTATIVG AT THE TIME OF THE FINAL MAINTENANCE WALKTHROUGH. 2. R[PLAC[ DEAD, DAMAGED, OR UNHEALTHY TREES, PER THE ORIGINAL DETAILS IMMEDIATELY UPON NOTIFICATION BY TIIF OWNrn·s llFPrlESENTAflVE. (THIS WILL BE AT NO COST TO THE OWNER.) REPLACEMENT TRf'.FS SHAU. MEET Tl-1F SAME SPECIHCATIONS AS THE ORIGINAL TREES. REPLACEMENT TREES SHALL BE GUARANTEED FOR 1 YEAR. FOLLOWING TIIFIR INSTALLATION AS DelEllMINEO BY THE OWNsR'S REPRESENTATIVE. 3. ALL SHRUBS, VINES AND GROUNDCOVER SHALL 8[ GUARANTErn FOR THE LENGTl-1 OF THE MAINTENANCE PeRIOD. 1. 2. SUBMIT, AT THE TIME OF DELIVERY, INVOICE STATEMENTS FOR ORGANIC AMENDMENTS AND FERTILIZERS CERTIFYING DELIVERY TO THE SITE AND QUANTITIES BY BULK AND/OR WEIGHT. SUBMIT SUPPLIHl'S STATEMENTS OF CONFIRMATION RECORDING COMPLIANCE OF ORGANIC AMENDMENTS AND FERTILIZtRS WITH THES[ SPECIFICATIONS. SUBMIT CeRTIFICATES FOR THE FOLLOWING ITEMS UPON DELIVERY TO TIIE JOB SiTt:: a. QUANTITY OF COMMERCIAi. FERTILIZEll AND ORGAMIC FEfHILIZtR. b. QUANTITY OF SOIL AMENDMENTS. c. QUANTITY OF SEED. d. QUANTITY OF OTl-1ER SOIL ADDITIVES Prn AGRONOMIC SOILS TEST llEPOIH. 4 SUBMIT WRITTEN CERTIFICATE OF DELIVERY OF CONTAlr<ER OR BULK MATERIALS. 5. SUBMIT WRITTEN CERTIFICATE OF QUANTITY AND QUALITY OF PLANT MATERIALS. MATERIALS: A. G!eNEll AL, 1. PROVIDE MATERIALS OF BEST QUALITY OBTAINABLE WHICH COMPLY WITH TH[ PLANS. 2. NO SUBSTITUTION OF SPECIFIED MATERIALS SHALL BE M/1DE WITHOUT WRITT[N APPROVAL OF THC OWNER'S REPRESENTATIVE. II, WEED CONTROL: 1. PRE-PLANTING HERBICIDE, ROUNDUP OR EQUAL. 2. PRE-EMERGl'NT WEED CONTROL, ROl4STAR-G. TRGFLAN. EPTAM, VEGITCX, OR EQUAL C. ORGANIC AMENDMENTS, DERIVED FROM WOOD OR BARK, GRANULAR IN NATURE, STABILIZED WITH NITROGEN, FORTIFIED WITH MINERALS AND HAVING THE FOLLOWING PROPERTIES, 1. PARTICLE SIZE, a. MINIMUM 95% PASSING A 4 MCSH SCREEN. b. MINIMUM 80% PASSING AN 8 MESH SCREEN. 2. NITROGEN CONTENT, (ALL VALUES BASED ON DRY WEIGHT) o.5% FOR REDWOOD SAWDUST, o.7% FOR FIR SAWDUST, 1.0% FOR CEDAR SAWDUST, 1.0%FOR FIR OR PINC BARK. DINE SAWDUST IS NOT ACCEPTABLE. 3. SALINITY, CONDUCTIVITY 3.5 MILLIMHOS/CM AT 25•C OR LESS AS DE:TERMINED IN SATURATION EXTRACT CONDUCTIVITY. 4. OllGANIC CONTENT, MINIMUM 90% BY WEIGHT. D. FERTILIZ~RS AMD MINERALS, 1. PROVIDE COMMERCIAL FCRTILIZER, UN!rORM IN COMPOSITION, FREE- ROWING, SUITABLC FOR APPLICATION WITH APPROVED EQUIPMHIT. DELIVERED TO TH£ SITE IN UN-OPCNED CONTAINERS, EACl-l FULLY LABU.LED ACCORDING TO APPLICABLE FERTILIZER LAWS, AND BEARING THG NAM[ OR MARK OF Tl-IC MANUFACTURER COMMcRCIAL FERTILIZER, a. SOIL PREPARATION b. c. d. HYDROSPRAY WEED CONTROL MAINTFNANCF, • • • • Fb]HIIIZER TYPE SHALL BE BASED ON RECOMMENDATION GIVEN IN THC SOILS ANALYSIS BY 'SOIL AND PLANT LABORATORY'. 2. SOIL SULFUR, FIRST QUALITY COMMERCIAL GRADs. 95% MINIMUM EIEMENTAL SUI.FUR. 3. TR!•C I-IUMA n; PLUS: COHMtPCIAL GRADE;: 011GANIC SOIL CONDITION GP W!T!-l 25% J-.iUMIC AC!D AND 7'fu CALCIUM AND 5% suu::u~. 4. flll-C HUMATE, COMMfrlCIAL GRADE OflGANIC SOIL CONDITIONER WITH 40% HUMIC ACID. s. TRI-C 6-2·4, COMMERCIAL GRAD• ORGANIC SOIL CONDITIONGR/FERTILIZER WITH 20% HUMIC ACID, 6% NITROGEN. 2% Pl-lOSPHORUS. 4% POTASH. AND 5% SULFUR 6. TRl·C IRON WITH MICRONUTRIENTS, NON-STAINING IRON (10% IRON SUCRATE), WITl-113% CALCIUM, 6% SULFUR, 5% MAGNESIUM, 2% MANGANESE AND 1% NITROGEN. 7. TRI-C ENDO NCT AMI, ENDO NH ARBUSCULAR MYCORRHIZAL INOCULUM 8. IRON SULFATE [(Fs2 (504)], FIRST QUALITY COMM[RCIAL GRAD[ 20% MINIMUM Ff. AS METALLIC. 9. AGfllCULTURAL GYPSUM (CALCIUM SULFATE. CA S04 2HO), FIRST QUALITY COMMERCIAL GRADE, 23% CA. 10. CALCIUM CARBONATE LIME, FIRST QUALITY COMMERCIAi. LIME n. TRI-C MVCORRHIZAL PACKETS, 7 GRAM MYCO PAKS. WITH 10% HUMIC ACID, AND MYCORRl!IZAL FUNGI AT A MINIMUM RATE oF 100 PROPAGULES/CC E. l>LAMT MATERIAL, 1. QUALITY, HEAL THY, VIGOROUS, NORMAL HABIT, FR££ OF WEEDS, INSECT INFESTATION. PLANT DISGASE. SUN SCALDS, BROKEN FOLIAGE. ABRASIONS OF THE BARK, AND OTHER DISFIGUREMENTS. QUALITY IN ACCORDANCt WITH THESE PLANS AND SPECIFICATIONS SHALL BE DETCRMINED BY THE OWNER'S REPRESENT A Tl.YE. 2. SIZE, THAT NORMALLY fXPECTED FOR COMMtRCIALLY AVAILABLE NURSERY STOCK FOR SP[CIES/V ARIETIES SPGCIFlsD IN THsSE PLANS. THE ROOT SYSTEM SHALi. FILL THE CONTAINER BUT NOT BE ROOT BOUND. SIZE IN ACCORDANCs WITH THGSf SP£CIFICATIONS SHALL BE DETERMINED BY THE OWNER'S REPRESENTATIVE. 3. REJECTION OR SUBSTITUTION, REMOVE REJECTeD PLANT MATERIAL FROM THE SITE IMMEDIAT[L Y AND REPLACE AT NO ADDITIONAL COST TO THE OWNER. SUBSTITUTIONS SHALL NOT BE PERMITTED UNLESS EXPRESSED CONSENT IS RECEIVED FROM Tll[ OWNER'S REPRESENTATIVE. 4. PROTECTION, HANDLE AND STORE Pl.ANT MATeRIAI.S TO PROTECT FROM SUN, WIND. AND OTHER INJURl[S OR DAMAGE. INJURY OR DAMAGE SHALL BE CAUSE FOR REJECTION EVEN AFTER INITIAL R[VIEW. 5. G. 5. QIJANTITIGS, CIRCLES, DOTS. OR OTHER PLANT SYMBOLS US[D WITHIN THC PLANS ARE THE AUTHORITY TO PLANT COUNTS AND SHALL DETERMINE QUANTITIES PROVIDED. QUANTITIGS SHOWN ON TH£Se DRAWINGS ARt APPROXIMATE AND ARI. ONLY FOR WE CONVENIENCE OF Tl-1E CONTRACTOR. PLANT SYMBOLS AND/OR "ON CeNTER" SPACING TAKE PRECEDENCE OVER PLANT QUANTITIGS SPECIFIED. CONTRACTOR SHALL INFORM OWNEll iMMFDIATi::LY OE ANY DISCREPANCIES BETWEEN QUANTITIES AND SYMBOLS SHOWN. MULCI-I, 1. MULCII MULCel SWALL BE 3/4' SIZE NITROGENIZE:D SHR[DDW MULCH. ACCESSORIES, ,. TREE rn:s, COMMLPCIALLV MANUFACTURED TIES FROM BLA.CK TIRE CASINGS, CUT TO A MINIMUM 10" LENGTH AND HeLD IN PLACE: BY 12 GAUGE GALVANIZED WIRE OR SPLIT PLASTIC HOSE WITH A MINIMUM LENGTH OF15". SPLIT PLASTIC HOSE SHALL Bl' "C!NCH rlE" 011 APPllOVED EQUAi.. 2. TREE STAKES, 12' I.ONG, STRAIGHT GRAINED LODGE POLL PIN[, cR[E OE KNOTS, CHECKS, SPLITS AND DISFIGUREMENTS, TREATED WITH CHROMATED COPPER ARSENA n:. CUPRESSUS SEMDERVIRENS (ITALIAN CYPRESS) SHALL BE STAKED WITH 16' LONG X 2• DIAMETER GALVINIZED STEEL POLE, PAINTED DARK GREEN 3 ROOT BARRIER, COPOL YMsR POL YPROPYLENt. INJtCTION MOLDED •. 080 THICKNESS ROOT BARlllfR AS MANUEACTURED BY DEEP ROOT CORPORATION. (800) 458·7668. USE MODEL NO. UB 24-2 ADJACENT TO CURBS AND PAVED SURFACES. USE MODEL NO. UB 36-2 OR UB 48-2 ADJACENT TO RH AINING WALLS OR BUILDING FOOTINGS. SEe PLANS AND DETAILS l'OR LOCATIONS. INSTALLATION, A. PERCOLA TIOH TE:STIHG, 1, UPON COMPLETION OF THE ROUGH GRADING OF THE SITE, THE OWNER'S REPRESENTATI% SI-IALL IDl'NTIFY A TYPICAi. LOCATION FOR 1 Or: Tl-II' LARGEST SPECIMEN BOX rni;es. THE CONTRACTOR SHALL sXCAVATE THE PITFOR Tl-lE TREE PER rnE PROJECT SPECIFICATIONS AND DETAILS. 2. WITH THE OWNFR PRFSENT, THE CONTRACTOR SHALL FILL THE PIT WITH WAT[R TO A DEPTH OF 12°. IF POSSIBLE. THs LCNGTH OFTIMs REQUIRED FOR Tl-le WATER TO PeRCOLATE INTO THE SOIL.LEAVING THE PIT EMPTY, WILi.. BE MEASURED BY THE CONTRACTOR AND VERIFIED BY THE OWNER'S REPRESENTATIVE. 3. WITHIN 6 HOURS OF THE TIME THE WATER HAS DRAINED FROM THE PIT THE CONTRACTOR, WITH THE OWNER PRESENT. SHALL AGAIN FILL THE PIT WITH WAT!;R TO A DEPTH OF 12". IF WATER DOES NOT COMPLETELY PERCOLATE INTO THE SOIL WITHIN 9 HOURS A DnERMINATION WILL BE MAD[ BY TH• OWNER AS TO Wl-1ETHER OR NOT A DRAINAGE SYSTEM TO EACH TREE WILL BE REQUIRED, B. WEED CONTROL, 1. MANUALLY REMOVE ALL EXISTING WEEDS AND GRASSES AND REMOVE Ff/OM SITE. 2. APPLY 200 LBS/ ACRE COMMERCIAL FERTILIZER TO ALL PLANTING AREAS. IRRIGATE 4 TIMES PER DAY DURING THE SUMMtR SEASON AND 2 TIMES PER DAY DURING OTHER SEASONS FOR 3 WEEKS TO GERMINATE SEEDS, 3. DISCONTINUE IRRIGATION FOR 2 DAYS AND APPLY A NON-SELECTIVE CONTACT HERBICIDE, PER MANUFACTURER'S DIRECTION, TO ERADICATE GERMINATED WEEDS AND GRASSES. ALLOW HERBICIDE TO KILL WEEDS AND GRASSES. MANUALLY REMOVE WEEDS AND GRASSES FROM SITE. MINIMIZE SOIL DISTURBANCE ON SLOPED AREAS OF THE SIT£. IF W[EDS AND GRASSES STILL CXIST. IRRIGATE 4 OR 2 TIMES PER DAY, AS ABOVE, FOil 2 WEEKS OR UNTIL NEW GROWTH APPEARS. REAPPLY HERBICIDE PER MANUFACTURER'S DIRECTION. ALLOW HERBICIDE TO KILL WEEDS AND GRASSES. MANUALLY REMOVE WEEDS AND GRASSES FHOM THE SITE:. 5. NO PRE-EMCRGENT HERBICID[ SHALL BC USSD IN LANDSCAPE AREAS TO BE SEEDED. 6. CONTRACTOR SHALL OBTAIN APPROVAL BY THE OWNER TO APPLY ANY HERBICIDE. INSECTICIDE. FUNGICIDE, OR OTHER CHEMICALS TO BE USED ON SITE. CONTRACTOR SHALL ABIDE BY ALL APPLICABLE GOVERNMENT Al. STANDARDS REGULATING THE APPLICATION OF ANY CHEMICALS. AND SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS. ALL WORKERS APPLYING SUCH CHEMICALS SHALL BE LIC[NSfD IF REQUIRED BY LAW. C. DELIVERY AND STORAGE, 1. CONTRACTOR SHALL Dell.YER SOIL AMENDMsNTS TO THE SITE IN me ORIGINAL UN OPENED CONTAINERS, BEARING THE MANUFACTURER'S GUARANTEED CHEMICAL ANALYSIS, NAME. TRADE NAME OR TRADEMARK, AND STATEMENT INDICATING CONFORMANCE TO STATE AND FEDERAL LAW. IN LIEU OF CONTAINE:RS. SOIL AMENDMENTS MAV BC FURNISl-1ED IM BULK. A CERTIFICATE INDICATING THe ABOVE INFORMATION SHALL ACCOMPANY EACH DELIVCRY. 2. CONTRACTOR Sl-lALL ARRANGE FOR OWNER'S REPRES.NTATIVE TO CERTIFY ALL UN-OPENED FERTILIZER PACKAGES ON SITE. FERTILIZER PACKAGES SHALL NOT BE RsMOVsD FROM SITE UNTIL AFTER INCORPORATION INTO SOIL AS PER SP[ClrlCATIONS, AND ONLY WHCN DIRECTED BY OWNCR'S REPRESENTATIVS. 3. CONTRACTOR SHALL STOR[ AND PROTECT PLANTS NOT INSTALLGD ON TH[ DAY OF ARRIVAL AT THE SITE. INT~GRATION ~iiiiiiiiil DE;SIGN STUDIO P L A N 160d06 D. F. D A T .: lsl Submittal REVISIONS LANDSCAPE: ARCHITECTS 5411 Avenida Encinas. Suite 270 Carlsbad, CA 92oo84380 l 760.602.01-44 f 760.602.0388 www,INTGGRATIONk0E:SIGN,gc,m SOIL PRE:PARATION, TH[ CONTRACTOR SHALL HAVE OBTAINED RESULTS FROM SOIL TESTING TO DETERMINE IF SOIL IS TO BE IMPORTED OR IF ON SITE SOIL WILL BE AMENDED. FINISH GRADING, MOUNDING, SOILS TESTING AND WEED CONTROL SHALL BE COMPLtn:D PRIOR TO SOIL PREPARATION. 1. AM[NDING ON SITE SOIL a. CROSS-RIP ON GRADE PLANTING AR[AS TO A DEPTH OF 10"-12' IN 2 DIRECTIONS. b. APPLY PER 1,000 SQ. FT. OF PLANTING AREA (EXCLUDING SLOPCS GRl'ATfP THAN 2,1). THESE RATES MAY BE ADJUSTED BY THE SOILS REPORT AND ARE FOR BIDDING PURPOSGS ONLY, ORGANIC AMENDMENT COMMeRCIAL FERTILIZCR SOIL SULFUR _,t_CU.YDS. -35..._ LBS. __15.__ LBS. TRI-C HUMATE _..s_g__ LBS. AGRICULTURAi. GYPSUM _JQQ__ LBS. c. BROADCAST THE ORGANIC SOIL AMENDMENTS LJNll'ORMI.Y OVER SURFACE OF THE ARsA TO B[ TREATED. INCORPORATE INTO THE SITE SOIL BY CULTIVATION, SPADING, OR ROTO-TILLING, TO A DLPTI-I OF C AND FINE GRADE TO SP[CIFIED DEPTH BeLOW ADJACENT PAVING AND CURBS. REMOVE r:ROM ALL PLANTING AREAS, ROCKS AND DEBRIS LARGER THAN 1" AND REMOVE l'ROM THE SITE, CLEAN MINER1,L AND AMsNDMGNT STAINS FROM PAVING. d. MOISTURE CONTENT, TH£ SOIL SHALL NOT BG WORKED WHEN THE MOISTURE CONTENT IS SO GR[AT THAT EXC[SSIVE COMPACTION WILL OCCUR, AND NOT WHEN IT IS SO DRY THAT DUST WILL FORM IN THE AIR. WAT•R SHALL Be APPLleD. IF NsCESSARY, TO PROVIDE ID[AL MOISTURE CONDITIONS. 2. BACKr.lLL MIX, ,. STANDARD BACKFILL MIX, usr; ON SITE SOIL BASED ON THE SOILS REPORT, nus MIX IS FOR BIDDING ONLY. BLEND PER CUBIC y ARD, TOPSOIL/IMPORT SOIL , PARTS BY VOLUME ORGANIC AMENDMeNT TRI-C HUMAT[ TRI-C IRON W/ MICRONUTRIENTS AGRICULTURAL GYPSUM FGRTILIZER (6-20-20) 1 PART BY VOLUME 6 LBS PER CUBIC YARD or MIX 2 LBS PER CUBIC YARD OF MIX 5 LBS PER CUBIC YARD OF MIX 1.5 LBS PER CUBIC YARD OF MIX ' b. ACID LOVING PLANT MIX, U~E ON SITE SOIL, BAS[D ON THC SOILS REPORT. THIS MIX IS FOR BID•llNG ONLY. SFF PLAN FOR INDICATION OF ACID LOVING PLANT MATE IAL. BLEND PER CUBIC YARD, TOPSOIL/IMPORT SOIL 1 PARTS BY VOLUME NITROLIZING ORGANIC AMEN! MENT 5 PARTS BY VOLUME COMPOSTED LEAF MOLD TAI-C HUMATE TRI-C IRON W/ MICRONI/TRI[~ -s AGRICUL TI.JRAL GYPSUM FERTILIZER (6-2<>20) 4 PARTS BY VOLUME 4 LBS PER CUBIC YARD OF MIX 2lBS PER CUAIC YARD OF MIX 5 l AS PER Cl/AIC YARD OF MIX 1.5 I.AS PER CUBIC YARD OE MIX l=IHISI-I GRADING, 1. PRIOR TO THE COMMENCEMCNT OF PLANTING OPERATIONS. COMPLETE FINISl-l GRADING AS SPSCIFIED . 2. WHEN PRELIMINARY GRADING, INCI..LJDING WEEDING AND FERTILIZING IOAS BEEN COMPLETED. AND THE SOIL HAS DRIW SUFFICIENTLY TO BE READILY WORKED, PLANTING AflEAS SHALL BE GRADED TO UNIFORM LEVELS Ofl SLOPES AT A MINIMUM OF 2%. MINOR ADJUSTMENTS TO FINISH GRADES SHALL BE: MADE IN THE DIRECTION OF THE FLOW. LOW SPOIS AND POCKi::TS SHALL BE GRADSD TO DRAIN PROPERLY. GRADING SHALL BE DONE WHEN SOIL IS AT OPTIMUM MOISTURE CONTENT EOR WORKING. QOCK ANO DEBRl'l MORE THAN 1" IN DIAMETeR SHALL BE R[MOVED FROM THE SITE. PLANTING 1. TREES, SHRUBS AND VINES, a. THE OWNER'S REPRESENT A TIVf Sl-1ALL APPROVE THE PLACEMENT OF ALL PLANT MATERIAi. BEFORE PLANTING PITS ARE EXCAVATED, TH[ CONTRACTOR SHALL LAYOUT PLANT LOCATIONS FOR SHRUGS AND VINES, OR PLACE SPECIFIED ClUANTITl£S OF Pl.ANTS IN CONTAINERS AT LOCATIONS SHOWN ON PLANS. CONTRACTOR SHALL LOCATE TRsES 24" BOX AND SMALLER WITH MARKER STAKES. CONTRACTOR SHALL LOCATE TREES 30" AND LARGGR WITH MARKCR STAKES. AND FLAG THE NORTH SIDE OF EACH TREe. CONTRACTOR SHALL HAVE ALL PLANT MATERIAL LOCATED PRIOR TO THE SITE VISIT BY THE OWNER'S REPRESJ'.NTA TIVE. b. PLANT MATERIALS AS SOON AS SITE IS AVAILABLE AND WEATHrn CONDITIONS ARE SUITABLE FOR PERFORMANCE AND THE SEQUENCE OF THs SPECIFICATIONS. DO NOT PLANT IF THE SOIL IS EXCESSIVELY WET. c. EXCAVATE PLANT PITS 2 TIMES WIDER TIIAN TIIE PLANT CONTAINER. EDGeS SHALL BE 6'0R MORE AWAY FROM CURBS AND PAVING. d. SET PLANTS IN CENTER OF PITS, IN VERTICAL POSITION SO THAT CROWN OF PLANT IS 1" ABOVE ADJACENT FINISH GRADE. BACKFILL PLANT PIT WITH BACKFILL MIX TO 1/2 THE HEIGIIT OF THE ROOT BALI. AND WATER e. MYCORRHIZIAL PACK£TS, PLACE PsR THE FOLLOWING SCHEDULE, • l GAL. 7 GRAM PACKET , 5 GAL. 3 7 GRAM PACKns • 15 GAL .. 24" BOX 8 7 GRAM PACKETS ,30"BOX, 36"BOX 16 7 GRAM PACKETS • 42"BOX. 48"BOX 22 7 GRAM PACKETS f. g. h. ,. CONTINUE BACKFILLING AND FORM SHALLOW BASIN AROUND EACl-l EDGE OF ROOT BAU BY DEPRESSING SOIL SLIGI-ITLV BeLOW FINISH GRADE, FORM BASIN RIMS. KEfPING RIM WITHIN OUTER EDGES OF ROOT BALL WATER TO SATURATE ROOTS AND FINISH B,~CKFILL AROUND ROOT BALL. FINE GRADE AREAS AROUND PLANTS TO SPECIFIED FINISH GRADG AND DISPOSE OF EXCESS SOIL. PRUNE AND SHAPE ALL TREES. SHRUBS AND VINES, AS DIRECTED BV OWNER'S REPRESsNTATIV£. REMOVE STAKES AND ESPALIER RACKS AND SECURE VINES TO AD.IACFNT MASONRY SURFACES WITH SCREW GYES OR M[TAL FASTENsRS, AND HEAVY DUTY CLEAR PLASTIC IRS ON WOOD SURFACES. ALUMINUM NAILS WITl-1 HEAVY DUTY CLGAR PLASTIC TIES MAY BE USED IN LIEU OE METAL FASTENERS. j. SLOPES 3' AND HIGHER IN VERTICAL ELEVATION SHALL 6[ PLANTED WITH GROUNDCOVER. SLOP£$ 15' AND HIGHCR IN ELEVATION SHALL BE Pl.ANTED WITH GROUNDCOVER, TREES AND SITRUBS. "NATIVE' CONTAINCRIZED PLANTS, INCLUDING LINERS. SHALL BC PLANTED 30 DAYS PRIOR TO THE END OF THE MAINTENANCE. PEfllOD FOil I-IYDROSEEDED SLOP[ AREAS. PRIOR TO n-H; END OF THE MAINTENANCE PERIOD THE CONTRACTOR SHALL RE-HYDROSEED AREAS DISTURBsD FROM PLANTING LINERS. I. TREES SHALL BE PLANTED AT LEAST 5• FROM ANY DRIVEWAY, DRAINAGE: FLOW LINE. UNDERGROUND UTILITIES SUCH AS SEWERS. WATeRLINES, GAS LINES. SIDEWALKS, AND BUILDINGS, ETC. m. TREES SHALL BE PLANTED AT LEAST 2,l FROM ANY STRE[T INTeRSECTIONS, PEDfSTRIAN CROSSWALKS. OR STREET LIGHT STANDARDS. n. ALL TRE[S SHALL BE PLANTED AT LEAST 5' Bel-JIND CITY RIGHT-OF- WAY. o. ALL TREES SelALL BC PLANTED WITHIN THE CITY RIGHT-OF-WAY. p. PLANTINGS SHALL NOT BE LOCAT[D SUCH THAT THEY WOULD CAUSe A LINE OF SITE PROBLEM FOR VEHICULAR TRAFFIC. 2. GROUNDCOVER, a. PLANT GROUNDCOVER TO COVER Tl-I[ DESIGNATED AREAS AT THE SPfCIFlsD ON CENTER SPACING. b. ALL GROUNDCOVER SHALL EXTEND UNDERN[A TH ALL TREES AND SHRUBS IN Pl.ANTING BEDS. c. PLANT GROUNDCOVER IN STRAIGi4T ROWS, EVENLY SPACED USING TRIANGULAR SPACING UNLESS OTHERWISE NOTED ON PLANS. d. INSTALL 1 . 5 GRAM FERTILIZGR TABLET WITH EACH GROUNDCOVER PLANT. e MOISTEN SOIL BEFORE PLANTING. RETAIN SLIGHT DEPRESSION AROUND EACH PLANT. FINISH WITH NEAT AND UNIFORM FINISIJ GRADeS. f. HAND WATER IMMED!A TEL Y AFTER PLANTING. PLANTS SHALL NOT BE ALLOWED TO DRY OUT BEFOR[, DURING, OR AFTER INSTALLATIQrl. CONTINUE TO HAND WATER AS REQUIRED FOR I MONTH. G. MULCH, 1. SHRUB AND GROUNDCOVER AREAS Sl-1ALL REC[IVE A 3" DePTH OF MULCH AS A TOP DRESS. H, ACCESSORIES: l. TREE TIES, WHEN USED AT CONTRACTOR'S DISCRETION. INSTALL PER on AIL. 2. TREE STAKES, WHEN USED AT CONTRACTOR'S DISCRi::TION, 11;STALL PCR DETAIL 3. GUY WIRES, WHEN USED AT CONTRACTOR'S DISCRETION. INSTALL PGR DHAIL. 4. GUY WIRE HOS[, WHEN USED AT CONTRACTOR'S DISCRETION, INSTALi PFR DETAIL. 5 ROOT BARRIER, INSTALL Pm MANUFACTURER'S RECOMMENDATIONS. I. MAIMTEHAMCE, 1. MAINTAIN PROJECT FOR A PERIOD OF 2Q CALENDAR DAYS, FOLLOWING THe CORRECTION AND/OR COMPLHION OF PRE-MAINTENANCE WALKTHROUGH PUNCH LIST IThMS IDENTIFIED BY Tl-1E OWNER'S REPRfStNTATIVE. MAINTENANCf PfRIOD SHALL NOT COMMENCG UNTIL EVID[NC[ OF OWNhR'S REPllESENTATIVE'S SATISFACTION IS ReCEIVED IN WRITING. 2. MAINT[NANCE SHALL INCLUDE BUT NOT BE LIMITED TO TRIMMING, PRUNING, WATERING, FERTILIZATION, WEED CONTROL, CULTIVATION. PEST CONTROL, CLEAN-UP, OPGRATION/ADJUSTMENT AND REPAIR OF THG IRRIGATION SYSTEM. 3. APPLY COMMeRCIAL FERTILIZER AT THE RATE RECOMMENDED BY 'SOIL AND PLA,~T LAB', AS REQUIRED TO ESTABLISH THRIVING PLANTS. 4 PROTECT NfWLY PLANTED AREAS FROM FOOT TRAFFIC, VANDALISM, THEFT, BURROWING OR GRAZING ANIMALS, AND EROSION. REPAIR ANO REPLANI DAMAGED ARCA, RCPLAC( DeAD. DAMAGED. OR MISSING PLANTS. s. COMPLETION OF MAINTeNANCE PERIOD AND PLANT ESTABLISHMENT SHALL Bf DETERMINED BY THE OWNER'S REPRESEN I.A I !VE, IN WRI I ING, FOLLOWING A FINAL MAINTENANCE WALKTl-1ROUGH. J. CLEAN-UP, 1. UPON COMPLETION OF WORK IN THIS SECTION, CONTRACTOR SHALi. REMOVE ALL RUBBISH, TRASl-1. AND DEBRIS RESULTING FROM THE OPERATIONS, REMOVE UNUSED EQUIPM[NT AND IMPLEMENTS OF SERVICE, LEAVE ENTIRE AREA INVOLVED IN A NsAT AND ACCEPTABLE CONDITION SUCH AS TO MEET THE APPROVAL OF THE OWNER'S REPRESENTATIVE. CUPOS-03 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION or PLANTING AREA. t-----+--+----------1---t---t--t----1 I s~~T 11 CITY OF CARLS BAD l----+---1-------------------1---·~ '· -·--·---,--·f---+----,1 - SHEETS 14 ~-----------------------LANDSCAPE PLANTING SPECIF/CA TJONS: LA COSTA LOT 1.3 RV PARKING APPROVED DATE DWN BY: ____ _ DRAWING NO. DATE INJTIAL ENGINEER OF WORI REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKD BY: ___ _ RVWD BY: 442-7L "? 0. L------------------------------------------------------------------------------------------------------------------------------------------------J..J Z\2005 P R 0 J E C T $\05.C0a Lo Costo RI/\Drowing filo:i\CD's\SPECS.dwg\?LANT!NG-SP£C\9 Jori 2007 8:55 AM br; StotionJ