HomeMy WebLinkAboutSDP 2018-0022; RESORT VIEW APARTMENTS; PRELIMINARY DRAINAGE STUDY; 2019-10-15IDB ENGINEERING Professional Civil Engineer and Land Surveyor Preliminary Drainage Study for Resort View Prepared for: BNR INVESTMENT & DEVELOPMENT, LLC 23800 VIA DEL RIO YORBA LINDA, CA 92887 (714) 692-9120 Proiect Site Address Viejo Castilla Way, Carlsbad, CA Prepared by: Michael L. Benesh, R.C.E. 37893 Date: October 15, 2019 404 South Live Oak Park Road Fallbrook, CA 92028 7 60 731-6603 -·~ City of Carlsbad OCT 2 2 2019 Planning Division Engineering Resort View Preliminary Drainage Study Contents Section 1. Certification ............................................................................................... 2 Section 2. Discussion ................................................................................................. 2 Section 2.0 l Purpose .......................................................................................... 2 Section 3. Project ........................................................................................................ 3 Section 3.01 Description ..................................................................................... 3 Section 3.02 Topography and Land Use .......................................................... 3 Section 3.03 Off-Site Drainage .......................................................................... 3 Section 4. Methodology .............................................................................................. 5 Section 4.01 Rational Method ........................................................................... 5 Section 4.02 Unit Hydograph ............................................................................. 6 Section 4.03 Hydraulics ...................................................................................... 6 C Section 5. Summary .................................................................................................... 8 Section 5.0 l Post Construction Storm Runoff Impacts .................................... 8 5.0 l . l Storm Runoff Entering the Site ..................................................... 8 5.01 .2 Storm Runoff .................................................................................. 9 Attachment A -Vicinity Map ............................................................................................. A-1 Attachment B -Hydrology Map .......................................................................................... B-1 Attachment C -San Diego County Soils Group Map ...................................................... C-1 Attachment D -San Diego County Hydrology Manual Excerpts ................................... D-1 Attachment E -San Diego County Point Rainfall Maps .................................................... E-1 Attachment F -TC Calculations .......................................................................................... F-1 Attachment G -Rational Method Calculations ................................................................ G-1 Attachment H -Post Development Ql 00 Calculations .................................................... H-1 Attachment I -Hydraulic Calculations ............................................................................... 1-1 October 15, 2019 Page 1 C:\MLB Projects\County of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx C C Engineering Section 1. Certification Declaration of Responsible Charge Resort View Preliminary Drainage Study I hereby declare that I a m the engineer of work for this project as defined in Section 6703 of the Business and Professions Code, and that the design is consistent with current standards. I understand that the check of prject drawing and specifications by the City of Carlsbad is confined to a review only and does not relieve me, as engineer of work, of my responsibilities for project design. ~--C~ L_C_ -10/15/19 Michael L Benesh, RCE 37893 Section 2. Discussion Section 2.01 Purpose Date RCE 37893 The purpose of this study is to determine the existing and anticipated 100-year storm runoff and required size of hydraulic structures to protect the proposed and existing slopes and structures on the site, and to identify existing drainage problems that may be caused, or aggravated, by project development. The project is required to meet County of San Diego Hydromodification Mitigation that requirement that the Post-project runoff conditions (flow rates and durations) must not exceed pre-development runoff conditions by more than 10 percent for storms in the range of 0. 1 Q2 up to to the ten year storm event. The SWQMP for the project contains the hydromodification management plan and supporting October 15, 2019 Page2 C:\MLB Projects\County of San Diego\17~,t()() Resort View Ca\Drainage Study\Resort View PreHminary Drainage Study.docx ( ( Engineering Resort View Preliminary Drainage Study calculations. The detention tanks being proposed to satisfy the hydromodification requirements will also act to reduce the peak storm runoff from a 100-year storm event. Section 3. Project Section 3.01 Description The project is a 0.858 acre site located in the City of Carlsbad, California. The site is bordered by Viejo Castilla Way to the east, a golf course to the south, and multi-family residential developments to the north and west. The site does not caontain any natural drainage channels or significant natural vegetation. The project site is currently vacant. The proposed project includes the construction of a 26 unit apartment complex in 4 buildings. The project parking will be inside covered garages and carports below each building. The construction will include driveways, buildings and the extension of utilities from Viejo Castilla Street into the site. The proposed activities will be typical attached residential living. A detailed vicinity map is included in Attachment A. Section 3.02 Topography and Land Use The site slopes generally down from the southwest corner to the northeast corner. The runoff from the site drains overland to Viejo Castilla Way on the east side of the site. The runoff travels north in Viejo Castilla Way to Navarra Drive and then east to an inlet in the cul-de-sac. From there it conveyed to San Marcos Creek by means of a city storm drain system, and a concrete lined watercourse through the golf course to the north of the project site. Section 3.03 Off-Site Drainage There does not appear to be any significant runoff entering the project site from the adjoining properties. The previously developed site to the west is generally lower than the project site and does not drain onto the project site. The Golf Course to the south October 15, 2019 Page3 C:\MLB Projects\County of Son Diego\ l 7-sd400 Resort View Ca\Drainage Sludy\Resort View Preliminary Drainage Study.docx C ( Engineering Resort View Preliminary Drainage Study does have some drainage running onto the site that will be directed along the property line retaining walls to the street after development. The property to the north is much lower than the site and slopes away. October 15, 2019 Page4 C:\MLB Projects\County of San Diego\ l 7-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx Engineering Resort View Preliminary Drainage Study Section 4. Methodology Section 4.01 Rational Method The Rational Method as described in the San Diego County Hydrology Manual, Section 3, (Revised June 2003) shall be used to determine storm runoff. The Rational Method formula is expressed as follows: Q=CIA Where: Q = peak discharge, in cubic feet per second (cfs) C = runoff coefficient, proportion of the rainfall that runs off the surface. The coefficient C has no units and is based on the soil group and the development type for the drainage sub-area. Attachment F includes calculations for the runoff coefficient for each drainage sub-area. I= average rainfall intensity for a duration equal to the Tc for the area, (in/Hr.) A = drainage area contributing to the design location, in acres The following values are used in the calculations: Soil Group D from San Diego County Soils Group Map. See Attachment C. C (Coefficient of Runoff) from Table 3-1. 100 year 6 Hr. Rainfall= 2.7" 100 year 24 Hr. Rainfall =4.8" See Attachment D. See Attachment E. " " The site is first divided into drainage sub-areas. See the On-Site Hydrology Maps in Attachment B. The time of concentration, Tc, for each sub-area along the drainage path is computed based on the initial time of concentration for the initial area and the travel time to reach each succeeding node. Based on the time of concentration, the rainfall intensity is determined using Figure 3-2 (See Attachment D ) . Then applying October 15, 2019 Page 5 C:\MLB Projects\Counly of San Diego\ 17-sd400 Resort View Ca\Dralnage Study\Resort View Preliminary Drainage Study.docx c· Engineering Resort View Preliminary Drainage Study the rational method equation, the peak runoff is determined at each node along the drainage path. Q's are tabulated for each sub-area along the drainage path. The rational method calculations are in Attachment G. Section 4.02 Unit Hydograph The Rational Method Unit Hydrograph procedure as described in the San Diego County Hydrology Manual, Section 6, shall be used to determine time based storm inflow into the detention tanks. Using this information, and the capacity of the tanls, the effect of the storage tanks on the peak outflow can be determined. For the creation of the Rational Method Hydrograph, a 100 year, 6-hour storm event and a Time of Concentration, Tc, approxiimately equivalent to the Tc determined in the rational method calculations is used. Peak flow is assumed to occur four hours into the storm. The incremental flows for each time period are then arranged in descending order, two thirds before and one third after, around the peak flow to construct the hydrograph. The hydrograph calculations are in Attachment H. Section 4.03 Hydraulics Hydraulic Capacity is determined by use of the Mannings Equation. The Mannings formula is expressed as follows: V = 1.49(R 2/3 5112 )/n Where: V = velocity (ft./sec.) R = hydraulic radius which h is determined by dividing the area of flow by the wetted perimeter (ft.) s = slope of conduit or channel (ft./ft.) n= Mannings roughness factor for the conduit or channel Autocad Hydraflow Express is used to determine the flow in the parkway culverts. Inlet Capacity is determined using the weir equation. October 15, 2019 Pages C:\MLB Projecfs\County of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx C ( Engineering Q=3Lh312 or h=(Q/3L)213 Where: Q = flow (cfs) L = perimeter of the inlet (ft.) h = depth of water at the grate (ft.) The calculations are included in Attachment I. October 15, 2019 Resort View Preliminary Drainage Study Page7 C:\MLB Projects\Counly of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx ( Engineering Resort View Preliminary Drainage Study Section 5. Summary Section 5.01 Post Construction Storm Runoff Impacts The proposed project will substantially alter the drainage patterns on the site, but will not alter the off-site or the surrounding area drainage patterns. The Storm water discharge points after development will not divert runoff from existing conditions. The potential polutants generated by the additional impervious areas will be mitigated by directing the flows through bio-filtration BMPs prior to draining to the street. These infiltration BMPs will be sized to treat the storm runoff from the site. A sump pump system and detention tank will provide flow control per the County of San Diego Hydromodification Management Plan and therefore the project will not increase the rate or amount of surface runoff in a manner which would result in flooding on-or off- site. If fact, the calculations indicate that the post development 100-year peak runoff will be considerably less than the storm runoff from the existing site in the same size storm. The proposed project will not alter the course of a stream or river, in a manner which would result in erosion or siltation either on-site or off-site. The proposed project will not create or contribute runoff water which would exceed the capacity of existing or planned storm water drainage systems. The potential increases in runoff flows flow from the site will be mitigated by the inclusion of hydromodification BMPs in the site drainage system. The project will not place housing within a 100-year flood hazard area as mapped on a federal Flood Hazard Boundary or Flood Insurance Rate Map or County Floodplain Maps as the site to be developed is not within a floodplain. 5.01. 1 Storm Runoff Entering the Site There are approximately 0.062 acres of undeveloped (Golf Course)property to the south of the project that drain onto the project site. After construction, a concrete brow ditch along the south property line will direct the drainage from the south directly to Viejo Castilla Way, avoidingthe on-site BMPs. October 15, 2019 Pages C:\MLB Projects\County of San Diego\ 17~400 Resort View Ca\Drainage Sludy\Resort View Preliminary Drainage Sludy.docx ( C Engineering Resort View Preliminary Drainage Study 5.01.2 Storm Runoff The amount of driveway and parking exposed to storm runoff has been kept to a minimum through the use of parking garages located under the proposed residences, but there will still be an increase to the amount of impervious area prredominantly due to the construction of the buildings and drive aisles. This increase in impervious area will cause an increase the storm runoff from the project drainage area. Prior to development the project site has no impervious areas. After the site is developed, the impervious area will increase to 0.730 acres (31,804 sf), or 85 percent of the drainage area. A comparison of pre-and post-construction runoff for the site drainage basin is included in Table 5.2 below. Area Pre-Post-Net (Ac.) Const. Const. Change %Imp %Imp 0.920D 0 85 +85% A See rational method calculations. 8 See rational method calculations. c See Attachment H. Pre-Const. Runoff, QlO()A (CFS) 1.4 0 0.858 acres on-site + .0062 acres off-site. Un-mitigated Mitigated Net Post Const. Runoff, Q1008 Post Const. Change (CFS) Runoff, (CFS) QlQQC (CFS) 4.4 0.43 -0.97 The Detention Tank BMP has a storage capacity of 5,426 cf. per the SWQMP for the project. The anticipated runoff from the site in a 100-year 6-hour storm event is 6,777 cf per the calculations in Attachment H. The storage capacity of the detention tanks is 80% (5,426/6,777) of the storm runoff from the site. The peak flow will be attenuated by the BMPs and the overall peak runoff from the project will be substantially reduced after it is developed. The hydraulic calculations in Attachment I indicate that the proposed storm drain structures are adequate to protect the site during a 100-year storm event. The on-site storm drain pipes will be sized with the final plans. October 15, 2019 Page9 C:\MLB Projecls\County of San Diego\ I 7-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx Engineering Resort View Preliminary Drainage Study Attachment A -Vicinity Map SITE Portion of U.S.G.S. Encinitas Quadrangle. October 15, 2019 Page A-1 C:\MLB Projecls\County of San Diego\ I 7cSd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx ( ( Engineering Attachment B -Hydrology Map Attachment 8-1: Existing Condition Hydrology Map The full size map is included in folder at back of report. Attachment 8-2: Proposed Condition Hydrology Map. The full size map is included in folder at back of report. October 15, 2019 Resort View Preliminary Drainage Study Page B-1 C:\MLB Projects\County of Son Diego\ l 7-sd400 Resort View Co\Droinoge Sludy\Resort View Preliminary Drainage Study.docx Engineering Resort View Preliminary Drainage Study Attachment C -San Diego County Soils Group Map Soils Group Map Legend SdlGroupe r==) Gn>upA --PB c=i Gn,upC c:::::J Gn,up D SOLANABEAC c::::) U..d<a-1.onnlln,oct C=1 oe,,-u ............. October 15, 2019 C:\MLB Projects\County of San Diego\ I 7-sd<IOO Resort View Ca\Drainoge Sludy\Resort View Preiminory Drainage Study.docx Page C-1 r""' i () 0 ;;-n ~ 0 "' O' .,, CD .Q, ... CD ... !l ~ ~ N () 0 g C ::, "° '< Q. "' 0 ::, CJ ~- ~ ~ 8 "' CD [ :,; CD "' () 0 / CJ a s· 0 co CD !,: C 0. '< / "' CD IS ::i. :,; CD "' .,, al ~ ::, 0 '< CJ g. 0 co CD !,: C: ~ b. 0 (l )( I CD i;:, .... Tahle 3-1 RI MWF COEFFICIE'.\TS FOR l RDA'.\ .\IU:.\S Land Use Runoff Coefficient ··c· Soil Type NRCS Elements Coun ' Element:;; %IMPER. A B C D Undisturbed Natwal Terrain (Natural} Permanent Open Space o• 020 0.25 0 30 0 35 Low Density Residential (LOR) Resu:lenlial. 1.0 DU/A or less 10 027 0.32 036 0.41 Low Density Residential (LOR) Residenttal. 2 0 DlJ/A or less 20 0 34 0.38 042 0.46 Low Density Residential (LOR) Res1den1Jal. 2 9 DUI A or less 25 0 38 0.41 045 0.49 Medium Density Residential (MOR) Residential, 4.3 DU/A or less 30 041 0.45 048 0.52 Medium Density Residentnd (MOR) Res1den1Jal. 7.3 DlJ!A or less 40 048 0.51 0 54 0.57 Medium Density Residential (MOR) Res1denllal, 10 9 DlJ/A or less 45 0 52 0.54 0 57 0.60 Medium Density Residential (l\-lDR) Res1den1tal, 14 5 DlJ/A or less 50 0 55 0.58 0.60 063 Hil,!h Density Residential (HOR) Residential, 24 0 DlJ/A or less 65 066 0.67 0.69 0.71 High Density Residential (HOR) Res1denttal, 43 o DU/A or less 80 0.76 077 0 78 079 C:ommercialilnduslflal IN Com) Neighborhood Commercial 80 076 0.77 0.78 0.79 CommercaaVlndustnal (G. Com) General Commercial 85 080 0.80 0.81 082 CommerciaL'lndustnal (0 P. Com) Office Profeiisional/Commercial 90 083 0.84 0.84 0.85 Commercial1Jndustnal (Lmtited I.) L11111ted lndustnal 90 083 0.84 0.84 085 Commercial!lndustr1al General I. General Industrial 95 087 0.87 0.87 087 "The ,-alues associated with 0"1;, impervious may be used for direct calculat1on of the runoff coeflic1ent as descnbed m Section 3.1.2 (repreiienlmg the perv1ous nmoff coefficient, Cp, for the soil type). or for areas that will remam undisturbed in perpelmty Justaficatton must be given thal the area will remain natural fore\·er (e.g, the area is located in Cleveland National Forest). DlHA " dwelling WIiis per acre NRCS ~ Na11onal Resources Conservation Service n )> gt ~ = CQ Q s· -=-CD n CD ..,, ~ ~ ::,-::, --3 CQ CD :, ... C en A) :, C -· CD cg 0 0 0 C :, ~ :::c \iC Q. a -0 :1111 cg m \iC g_ s: ~ A) ~ :, ~ C CD A) 3 -:i m Q >< '< (') i CD .., Q "C IQ Ii CD ~ Q. '< C Engineering Resort View Preliminary Drainage Study Table 3-2 MAXIMUM OVERLAND FLOW LENGTH (LM) & INITIAL TIME OF CONCENTRATION (T1) Element* Dl l/ Sh, 1 o/1, 2% 3%, 501c, Acre LJ\,1 Ti LM Ti LM Ti LM Ti LM Ti "'.'Jatural 50 13.2 70 12.5 85 10.9 100 10.3 100 8.7 LDR 1 50 12.2 70 11.5 85 10.0 100 9.5 JOO 8.0 LDR 2 50 11.3 70 10.5 85 9.2 100 8.8 JOO 7.4 l,DR 2.9 50 10.7 70 10.0 85 8.8 95 8.1 100 7.0 MDR 4.3 50 10.2 70 9.6 80 8.1 95 7.8 100 6.7 l\..fDR 7.3 50 9.2 65 8.4 80 7.4 95 7.0 100 6.0 MDR 10.9 50 8.7 65 7.9 80 6.9 90 6.4 JOO 5.7 MDR 1-l.5 50 8.2 65 7.4 80 6.5 90 6.0 100 5.4 IIDR 24 50 6.7 65 6.1 75 5.1 90 4.9 95 4.3 HDR 43 50 5.3 65 4.7 75 4.0 85 3.8 95 3.4 '."I.Com 50 5.3 60 4.5 75 4.0 85 3.8 95 3.4 G.Com 50 4.7 60 4.1 75 3.6 85 3.4 90 2.9 O.P./Corn 50 4.2 60 3.7 70 3.1 80 2.9 90 2.6 Limited I. 50 4 ') 60 3.7 70 3.1 80 2.9 90 2.6 General I. 50 3.7 60 3.2 70 2.7 80 2.6 90 2.3 *Sec Tahk 3-1 for more tktailcd description October 15, 2019 C:\MLB Projects\County of San Diego\ l 7-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Sludy.docx 10% LM Ti l00 6.9 100 6.4 100 5.8 l00 5.6 l00 5.3 100 4.8 100 4.5 JOO 4.3 100 3.5 100 2.7 100 2.7 100 2.4 100 ') 1 -·- 100 2.2 JOO 1.9 Page D-2 () ;;- ~ i;; "tJ .2. ~ ;. () 0 C ::, < Q. ~ ::, 0 g 0 '.:'.'. __, ti 8 "' .. ~ s; .. t () 0 / ~ 5· 0 0 .. V> K '< / ~ ~ s; ~ l 3 5" 0 -< ~ ::, 2 a, ~ C ~ 8 0 n 0 tJ' ~ -~ ..., ~ ,0 100 •o ao 70 t-0 so 30 2.0 I , .. -::oi t oa 01 o.e 05 03 02 0 I ...... ....... ..... -,... I ....... ,.__ ... ... ' ..... I '-,, '--... ...... ~ ...... ,"" ~ ... "l ' ' ~f,. ...... . .,. ~-... ' -...... ... ,tj:: ' , ... ~ ' ,1 ~ ' -...;:: .... ' .... ......... ........ r--... l' -l q ........ 'N.. ·1i I I I ........ , .J.l I I I II I I I 111 I II I I I I ' • --~ -,. ,.. ,- t + l. -r--: . ' . r . ~ w: I 1 I 8 10 15 I I ,, J. ,, ,N ('' J ~ ~ ~~r'N ' ~ n, ... " I ~ ~" I I" I I I I " 111 1 11 Tl l 2D I II 11 1111111' ,111111 1,1 11,, II II 11 1 I I I I ~ ~, j ,I ~~ -~ " ~ ~ I' f ll f J "' 11 II Ii ~ I I I I II Ii , . 11:~ ,I ,ii, 1111/11 I i,f il!J,!.I' :I• 'I' I I EQUATION • 7 « Ps o-0645 -I I I " lnlDnuy (innw) -I Pe • 6-Houf Prtcpltlt,On (1n) 0 • OurabOn (m,n) -I ' Ii ljl I I ' ~!ill N ~ ~~ ~ ' I I 11. I ~I p,~ !'-:,.._ ,. ~~ I ' '-I ~ .... ~ ~I -,~ I,, I ~~ ~ ... '3 " l •' I I "'' .... ~ ... I ... r .. ---i..i .'. JI I -.11 I !I ...... '-f"I. '--I I I ... I II • J --,.., ... 1'""' I ' .... I I ,. ,~ 7)-l :r :-,. I I~ .... ' ' ... I -:-,..:-,, ' I 'I',, ' ,. ~---... "I; it t " ·.t . '. ~-t t ·• 11 ·'-:f=t 31 .., 1,1 I ,, 3.0 -2.7 2.5 2..0 u 10 <IC) 60 , 2 3 • 6 I Hautl lntanslty-Ountlon Desftn Chart· T.,._ Olr9ctloM for' Appllcldon: (1) From~ m..-de!emWle fl hr ond 24 hr~ for Ille Mlec:t.t freqlAlrley. Thele mape are~ 111 tne County Hydrology Mlroal (10, 50, and 100 yr l1llPI lncalded In the °'5io,I and Ptocotclure Manual). (2) Adjust 6 hr prec:ipibnan fd neceuary) so Iha' i Is~ the range of ll5% 10M,r, at lhe 2• hr prwcip,Cmao (nol appl,caple 10 Oesettt. (3) Plat 8 Iv pn,c:ip,latio'I on the right side d the c:hiwt. (4) Dfi,w e Ins throui;, !he pc,jnl p.lllllol lO the plotted lines ($) TN lne " the silen$lly-ourat>on curve for Che logiflOn being anal)'Ud .Appllclllh>n Form: (a) Se-laded lrequeney ..!Q.Q._year (b)Pe= ~ln.P,4 = ~.~= ~%12l :z, (c) AdJU$ted Psf21• 3:!._ 1n. {d) Ix• --m,n (e} I • __ lnJhr Now· This ~ replllett the ~-~requency CUMtS used since 1965. ,.a 2 u a :a.s t U3 3 7 212 lta ◄t◄ t:,O &a 74t ... I I Cl! 2!.3 3-17 ◄~1 .OI, !>90 1-7• It 130 1••2 .. t:k 1e •~ lit H I.Ill 112 2 IS i• 12J°171 .:11 Hom UCI 117 233 280 321 ,,,, ;JO OllJ U • I .. 201 14' PIO 1• .. 0tll 103 13' 172 101 Ul J ,0 ,t OflO OM 1 It "' I 7t ZOt ZJ!I tt os;a o• 1 oe ,:n u, 1• t12 O◄t OSI OU 102 12' 143 1.D tit O 1 0111 015 1 Q2 11 150 o o• on oe IN 0 t .. 0 •o aM 0 1 II .... 7M 6f.l ... 410 3i, l 10 2• t• , ... 1" 1111 , .. 011 Uo 07$ I I l<U 15-11 1010 11• 1212 8.U IU7 10 II ._.. 113 711 !Ut 513 &Al .,, s u seo 'IS •511 •111 31$ 319 .. , 2M :Ull 358 2A , •• ,. UO Ut US uo 117 2(M ,.., 1.)1 1.- 0~ O.t4 3-1 Engineering Resort View Preliminary Drainage Study 12 10 0 • • i l I ~ 2 '#-u II 14 " 10 Ot o, 07 01 04 --- - 1-1s --1 ... _, ,__,,= 01 1-----"'"' ~ n= 0175 ~ ~ c~ :;;;;u p..,.c1 Af SIOfN'TW. ST~~T ONt Gil>£ ONLY I I ,.,___ " .. ...,.,. c,.. I • I I ..,,!.h,. I ' --........: 10, I --. -..e..-. I ~. I r--... t-..... I .....,......... 7 ' I I J r--~, I ............... I 81,, .__ J ~ I J .......... -✓11 -....... 1 J 'I-. 7 I I I 7 --........... -:L -~-I ....... v., I -L il~~ ~lf_ ~~ ...___ I I ~ ', s"l ...... ~ .. ) I ,.............. I ) j I ~ 3/ -rt r1 ~ 7 i"'-.Q'? ... I ,I) .......... r-t• l I ............... I 1 ............... I'~ --~, ---) I ... ) ~'---........b't I ---, j ,·1 ........... l i ,....__ I ......... <! ........;.'J ... j ..... , ___ , J ...... 1,,. J ~-, ........... ""' I ,-._3t I ............ /' . " <J'/ ...... "!J ~ ..... Q' I /'.f:..:.<$, I ....... ~ I !JI ..... ~~ I I ,E, r-....1 T I L ... ' I J I ---I -....J , .......... , Tl/ ...... ...... ..... I ........ I .......... ~ j , J "· .......... I r--...... J ---......::.<,"·• .......... t--.1 , '-.....-....... I ·7-i'-.... -~ V I ~~ I/ r--.... I/ I"-~I .... I'-... UAWL! Cllll!o:0 •1G S•2.R. Cbol1 u,,,• Depth= 0 4 Vt1oc•v = 4 4 lp.a. I"--.. .... ' I 7 I t 10 n,llclu>,oa cc: ~ s > 20 JII ,IC) !,O SOURCE San ()9gO COIJlllY 1>91)ilrtn'enl of Sp«:111 Di1hcl SenlicH ONign !Aanual f I C. l It I' Gullw, ■IIU ~UiKJw11y Obu:lt<Hgv • Vvlix:lly CIUIII I a-6 I October 15, 2019 C:\MLB Projects\County or Son Diego\ 17-id<IOO Resoo View Ca\Droinoge S1udy\Resoo View Preimlnary Drainage S1udy.docx Page D-4 Engineering Resort View Preliminary Drainage Study Attachment E -San Diego County Point Rainfall Maps t ~ -1--------+---- j_t ! to . 1 I ()) 1 () .,,,,,.. t ~ ..,. .,,,,,. . (i) t r ~ 0 ()Ci) l t -+- I 1()1 -::>_ t 11 ;!1 l r-t+tl1 r j r ' 100 Year -6 Hour Rainfall October 15, 2019 Page E-1 C:\MLB Projects\County of Son Diego\ I 7""1400 Resort View Co\Droinoge Study\Resort View Prelminory Drainage Study.docx Engineering Resort Vfew Preliminary Drainage Study (_ OCEAN t t t-f • I I t .. .. + + l b 100 Year -24 Hour Rainfall October 15, 2019 Page E-2 C:\MLB Projects\County of Son Diego\ 17-sd400 Resort View Ca\Dralnage Study\Resort View Preliminary Drainage Study.docx Engineering Attachment F -TC Calculations Existing Condition Tc, Initial Area OMA 1 Total Area= 0.920 Acres % Imp = 0% Use Natural L=310', h=23' Initial Slope > 10% Ti=6.9 Min., Lm=lO0' L=210', h=13' Tt=( l 1.9(L/5280)3/h)0-385 = 0.023 hrs= 1.4 min Tc=6.9 + 1.4 = 8.3 min. Proposed Condition Tc, Initial Area DMA-P-10 Total Area = 0.290 Acres % Imp= 81.8% Use HOR 43 L=180' Initial Slope 1 % Ti=4.7 Min., Lm=65' Curb & Gutter @ 0.5% V=l .6 fps Tt=l 15'/(l.6 fps x 60 sec/min)= 1.2 min Tc=4.7 + 1.2 = 5.9 min. Tc, Initial Area DMA-P-20 Total Area= 0.439 Acres % Imp= 88.9% Use OP-Com L=135', h=l.3' Initial Slope 1 % Ti=3.9 Min., Lm=60' Curb & Gutter @ 0.5% V=l .7 fps Tt=75'/(l .7 fps x 60 sec/min)= 0.7 min Tc=3.9+0.7 = 4.6 min., Use 5 min. October 15, 2019 Resort View Preliminary Drainage Study Overland Flow Page F-1 C:\MLB Projects\County of San Diego\ I 7-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Sludy.docx ( Engineering Resort View Preliminary Drainage Study Attachment G -Rational Method Calculations The Rational Method as described in the San Diego County Hydrology Manual, Section 3, (Revised June 2003) shall be used to determine storm runoff. The Rational Method formula is expressed as follows: Q=CIA Where: Q = peak discharge, in cubic feet per second (cfs) C = runoff coefficient, proportion of the rainfall that runs off the surface. The coefficient C has no units and is based on the soil group and the development type for the drainage sub-area. Attachment F includes calculations for the runoff coefficient for each drainage sub-area. I= average rainfall intensity for a duration equal to the Tc for the area, (in/Hr.) A = drainage area contributing to the design location, in acres The following values are used in the calculations: Soil Groups from San Diego County Soils Group Maps. See Attachment C. C (Coefficient of Runoff) from Table 3-1. 100 year 6 Hr. Rainfall = 2.7" 100 year 24 Hr. Rainfall =4.8" See calculations on the folowing pages. October 15, 2019 See Attachment D. See Attachment E. II II C:\MLB Projects\County of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.dacx Page G-1 Rational Method Calculation Form Project: Resort View Drainage Soil %Imp A Area Type Area Acres C CA I:CA I Frequency 100 Year Developed Condition P6=2.7 in./hr Q Slope In./Hr. CFS Delays caused by biofilters & pumping ignored. DMA-P-10 D 81.8% 0.290 0.79 0.230 0.230 6.39 1.5 0.01 DMA-P-11 D 0.0% 0.009 0.30 0.000 0.230 6.19 1.4 To Pump 0.230 6.11 0.01 1.4 DMA-P-20 D 88.9% 0.439 0.83 0.360 0.360 7.11 2.6 DMA-P-21 D 0.0% 0.014 0.30 0.000 0.360 7.11 2.6 To Pump 0.360 7.02 2.5 0.01 Pump Confl 0.521 7.02 3.7 DMA-P-30 D 100.0% 0.033 0.90 0.030 0.030 7.11 0.2 DMA-P-31 D 0.0% 0.001 0.30 0.000 0.030 7.11 0.2 DMA-P-40 D 100.0% 0.038 0.90 0.030 0.030 7.11 0.2 DMA-P-41 D 0.0% 0.001 0.30 0.000 0.030 7.11 0.2 DMA-P-50 D 100.0% 0.032 0.90 0.030 0.030 7.11 0.2 DMA-P-51 D 0.0% 0.001 0.30 0.000 0.030 7.11 0.2 Tank Conf 0.611 7.02 4.3 DMA-P-60 D 0.0% 0.062 0.30 0.020 0.020 7.11 0.1 Section V L Tt '/Sec. Ft. Min. 12" 4 74 0.3 12" 4 30 0.1 12" 4 25 0.1 Tc Min. 5.9 6.2 6.3 5.0 5.0 5.1 5.1 5.0 5.0 5.0 5.0 5.0 5.0 5.1 5.0 Page G-2 Calculated by MB Date: 8/15/2019 Remarks Attachment F-L=180' h=2.1' Pipe flow to BF-1 Pipe Flow to Pump Attachment F-L=135' h=l.3' BF-2 Add-in Area Pipe Flow to Pump Pump Conf Small area, assumed. Add in area Small area, assumed. Add in area Small area, assumed. Add in area Tank Conf Small area, assumed. ~ Rational Method Calculation Form Project: Resort View Drainage Soil %Imp A Area Type Area Acres DMA-1 D 0.0% 0.920 C CA l:CA 0.30 0.280 0.280 I Frequency 100 Year Existing Condition P6=2. 7 in./hr. Q Slope In./Hr. CFS 5.13 1.4 Section V '/Sec. L Tt Ft. Min. Tc Min. 8.3 Page G-3 Calculated by MB Date: 8/15/2019 Remarks Attachment F-L=310' h=23' ( Engineering Resort View Preliminary Drainage Study Attachment H -Post Development Q100 Calculations. The Rational Method Unit Hydrograph procedure as described in the San Diego County Hydrology Manual, Section 6, shall be used to determine time based storm inflow into the detention tanks. Using this information, and the capacity of the tanls, the effect of the storage tanks on the peak outflow can be determined. For the creation of the Rational Method Hydrograph the following information is used: l 00 year, 6-hour rainfall, P6= 2.7" from Attachment E. Time of Concentration, Tc= 6 min. from Rational Method Calculations-developed site, Attachment G. CA= 0.69 from Rational Method Calculations for developed site, Attachment G. Rainfall intensity, I=7.44P6T-0.64s The Unit Hydrograph calculations on on the following pages. The storage capacity of the two detention pipes is 3, 135 cf each, or 6,270 cf when the water is at the overflow riser height of 7.5 feet. The outflow of the 0.3" orifice flowing freely with 7.5 feet of head is less than 0.01 cfs and wil lbe ignored for determining the peak outflow from the site. From the calculations, it can be seen 6-hour, l 00-year storm runoff from the site is just 108% of the detention pipe capacity of 6,270 cf. The tanks drain to the dry-wells at an elevation lower than the outflow to the street. Assuming no infiltration, the outflow of the orifice will be virtually zero as the water surface in the dry well will be well above it. The outflow from the tanks, and the site, will be approximately equivalent to the inflow. Therefore based on the hydrograph calculations, the tanks fill up at the 5 hour mark on the 6-hour storm. The peak inflow into the tanks after this point in time is 0.17 cfs. The actual outflow will be further reduce by the effects of infiltration and storage at the dry wells, but these calculations are more than sufficicient to demonstrate that the peak runoff after development will be much less than the current condition. October 15, 2019 Page H-1 C:\MLB Projects\County of San Diego\ l 7-sd400 Resort View Ca\Drainage Study\Resorl View Preliminary Drainage Study.docx Unit Oograph Calculation Form .r-,, rOH-2 Frequent, /oo Year Project: Resort View 6-Hour Storm Calculated by MB P6=2.7 in./hr. Date: 8/15/2019 Tc= 6 min. Pipe Storage 5,426 cf CA= 0.69 P6= 2.70 in UH Elapsed Effective Tank Tank Tank Tank Tank Tank Time Tc I p Time Time Rainfall Inflow Inflow Outflow Storage Depth Discharge Period Min. in/hr. in Period Hrs. in. Rate cfs Volume cf Volume cf CF Ft cfs 1 6 6.32 0.63 1 0.10 0.02 0.112 40 40 0.03 0.000 2 12 4.04 0.18 2 0.20 0.02 0.114 41 82 0.06 0.001 3 18 3.11 0.13 3 0.30 0.02 0.116 42 0 123 0.09 0.001 4 24 2.59 0.10 4 0.40 0.02 0.119 43 0 165 0.12 0.001 5 30 2.24 0.09 5 0.50 0.02 0.120 43 0 208 0.16 0.002 6 36 1.99 0.07 6 0.60 0.02 0.123 44 1 252 0.19 0.002 7 42 1.80 0.07 7 0.70 0.02 0.124 45 1 296 0.22 0.002 8 48 1.65 0.06 8 0.80 0.02 0.128 46 1 341 0.26 0.002 9 54 1.53 0.06 9 0.90 0.02 0.129 47 1 387 0.29 0.002 10 60 1.43 0.05 10 1.00 0.02 0.133 48 1 434 0.33 0.002 11 66 1.35 0.05 11 1.10 0.02 0.135 49 1 482 0.36 0.002 12 72 1.27 0.05 12 1.20 0.02 0.139 50 1 531 0.40 0.003 13 78 1.21 0.04 13 1.30 0.02 0.141 51 1 581 0.44 0.003 14 84 1.15 0.04 14 1.40 0.02 0.146 53 1 632 0.48 0.003 15 90 1.10 0.04 15 1.50 0.02 0.148 53 1 685 0.51 0.003 16 96 1.06 0.04 16 1.60 0.02 0.153 55 1 739 0.56 0.003 17 102 1.02 0.04 17 1.70 0.02 0.156 56 1 794 0.60 0.003 18 108 0.98 0.04 18 1.80 0.02 0.162 58 1 851 0.64 0.003 19 114 0.95 0.03 19 1.90 0.02 0.165 60 1 909 0.68 0.004 20 120 0.92 0.03 20 2.00 0.02 0.172 62 1 970 0.73 0.004 21 126 0.89 0.03 21 2.10 0.03 0.176 63 1 1,032 0.78 0.004 22 132 0.86 0.03 22 2.20 0.03 0.184 66 1 1,097 0.83 0.004 23 138 0.84 0.03 23 2.30 0.03 0.189 68 1 1,164 0.88 0.004 24 144 0.81 0.03 24 2.40 0.03 0.198 71 1 1,234 0.93 0.004 25 150 0.79 0.03 25 2.50 0.03 0.204 73 1 1,306 0.98 0.004 26 156 0.77 0.03 26 2.60 0.03 0.216 78 2 1,382 1.04 0.004 27 162 0.75 0.03 27 2.70 0.03 0.223 80 2 1,461 1.10 0.005 Unit Oograph Calculation Form n Frequent.., 100 Year OH-3 Project: Resort View 6-Hour Storm Calculated by MB P6=2.7 in./hr. Date: 8/15/2019 CA= 0.69 P6= 2.70 in UH Elapsed Effective Tank Tank Tank Tank Tank Tank Time Tc I p Time Time Rainfall Inflow Inflow Outflow Storage Depth Discharge Period Min. in/hr. in Period Hrs. in. Rate cfs Volume cf Volume cf CF Ft cfs 28 168 0.74 0.03 28 2.80 0.03 0.238 86 2 1,545 1.16 0.005 29 174 0.72 0.03 29 2.90 0.04 0.247 89 2 1,632 1.23 0.005 30 180 0.71 0.03 30 3.00 0.04 0.267 96 2 1,726 1.30 0.005 31 186 0.69 0.02 31 3.10 0.04 0.278 100 2 1,824 1.37 0.005 32 192 0.68 0.02 32 3.20 0.04 0.306 110 2 1,933 1.45 0.005 33 198 0.66 0.02 33 3.30 0.05 0.323 116 2 2,047 1.54 0.005 34 204 0.65 0.02 34 3.40 0.05 0.366 132 2 2,177 1.64 0.006 35 210 0.64 0.02 35 3.50 0.06 0.393 142 2 2,317 1.74 0.006 36 216 0.63 0.02 36 3.60 0.07 0.468 168 2 2,483 1.87 0.006 37 222 0.62 0.02 37 3.70 0.07 0.521 188 2 2,669 2.01 0.006 38 228 0.61 0.02 38 3.80 0.10 0.699 252 2 2,918 2.19 0.006 39 234 0.60 0.02 39 3.90 0.13 0.871 314 2 3,229 2.43 0.007 40 240 0.59 0.02 40 4.00 0.63 4.400 1,584 2 4,811 3.62 0.112 41 246 0.58 0.02 41 4.10 0.18 1.228 442 40 5,212 3.92 0.252 42 252 0.57 0.02 42 4.20 0.09 0.593 214 91 5,335 4.01 0.303 43 258 0.56 0.02 43 4.30 0.06 0.426 153 109 5,380 4.04 0.329 44 264 0.55 0.02 44 4.40 0.05 0.343 123 118 5,385 4.05 0.329 45 270 0.54 0.02 45 4.50 0.04 0.292 105 118 5,371 4.04 0.329 46 276 0.54 0.02 46 4.60 0.04 0.256 92 118 5,345 4.02 0.329 47 282 0.53 0.02 47 4.70 0.03 0.230 83 118 5,310 3.99 0.303 48 288 0.52 0.02 48 4.80 0.03 0.210 75 109 5,276 3.97 0.303 49 294 0.51 0.02 49 4.90 0.03 0.193 70 109 5,237 3.94 0.277 50 300 0.51 0.02 50 5.00 0.03 0.180 65 100 5,202 3.91 0.252 51 306 0.50 0.02 51 5.10 0.02 0.169 61 91 5,172 3.89 0.252 52 312 0.49 0.02 52 5.20 0.02 0.159 57 91 5,138 3.86 0.227 53 318 0.49 0.02 53 5.30 0.02 0.151 54 82 5,111 3.84 0.227 54 324 0.48 0.02 54 5.40 0.02 0.144 52 82 5,081 3.82 0.203 55 330 0.48 0.02 55 5.50 0.02 0.137 49 73 5,057 3.80 0.203 56 336 0.47 0.02 56 5.60 0.02 0.131 47 73 5,032 3.78 0.203 ~ 0 [)H-4 Unit Hy,../ograph Calculation Form Frequenc, /oo Year Project: Resort View 6-Hour Storm Calculated by MB P6=2.7 in./hr. Date: 8/15/2019 CA= 0.69 P6= 2.70 in UH Elapsed Effective Tank Tank Tank Tank Tank Tank Time Tc I p Time Time Rainfall Inflow Inflow Outflow Storage Depth Discharge Period Min. in/hr. in Period Hrs. in. Rate cfs Volume cf Volume cf CF Ft cfs 57 342 0.47 0.02 57 5.70 0.02 0.126 45 73 5,004 3.76 0.179 58 348 0.46 0.02 58 5.80 0.02 0.121 44 64 4,984 3.75 0.179 59 354 0.46 0.02 59 5.90 0.02 0.117 42 64 4,961 3.73 0.156 60 360 0.45 0.02 60 6.00 0.02 0.113 41 56 4,946 3.72 0.156 total 16.5 0.59 total 2.00 6,777 1,831 Unit O graph Calculation Form Project: Resort View Frequency ,00 Year 6-Hour Storm P6=2. 7 in./hr. Pa::, H-5 Calculated by MB Date: 8/15/2019 5.000 4.500 4.000 3.500 3.000 2.500 2.000 1.500 1.000 0.500 0.000 V'l LL u -Inflow -Tank Outflow 000000000000000000000000000000000000000000000000000000000000 ~Nm¢~~~~mOMNm¢~~~oomo~Nmv~w~oomo~Nm~~~~oomorlNm¢~~~oomoMNm¢~~~oomo ciOOciciOciciO~~~~~~~~~~NNNNNNNNNNMmmmmmmmmMq¢~q¢qqq¢~~~~~~~~~~~~ Time (hours) Unit Oograph Calculation Form Project: Resort View Pipe Lookup Table I Depth (ft) I Storage (A-F) I 0.00 0.000000 0.05 0.001442 0.09 0.002884 0.14 0.004325 0.19 0.005767 0.24 0.007209 0.28 0.008651 0.33 0.010093 0.38 0.011535 0.43 0.012976 0.47 0.014418 0.52 0.015860 0.57 0.017302 0.61 0.018744 0.66 0.020185 0.71 0.021627 0. 76 0.023069 0.80 0.024511 0.85 0.025953 0.90 0.027395 0.94 0.028836 0.99 0.030278 1.04 0.031720 1.09 0.033162 1.13 0.034604 1.18 0.036045 1.23 0.037487 1.28 0.038929 1.32 0.040371 1.37 0.041813 1.42 0.043255 1.46 0.044696 1.51 0.046138 1.56 0.047580 1.61 0.049022 1.65 0.050464 1.70 0.051905 1.75 0.053347 Storage (CF) I 0 63 126 188 251 314 377 440 502 565 628 691 754 816 879 942 1005 1068 1131 1193 1256 1319 1382 1445 1507 1570 1633 1696 1759 1821 1884 1947 2010 2073 2135 2198 2261 2324 "' . I Frequent., ,00 Year Outflow (cfs) 0.0000 0.0009 0.0013 0.0016 0.0019 0.0021 0.0023 0.0025 0.0027 0.0028 0.0030 0.0031 0.0033 0.0034 0.0035 0.0037 0.0038 0.0039 0.0040 0.0041 0.0042 0.0043 0.0044 0.0045 0.0046 0.0047 0.0048 0.0049 0.0050 0.0051 0.0052 0.0053 0.0053 0.0054 0.0055 0.0056 0.0057 0.0057 6-Hour Storm P6=2.7 in./hr. 0 iJ ... l:IJ H-6 Calculated by MB Date: 8/15/2019 Unit 11Jograph Calculation Form Project: Resort View Pipe Lookup Table I Depth (ft) I Storage (A-F) I 1.79 0.054789 1.84 0.056231 1.89 0.057673 1.94 0.059115 1.98 0.060556 2.03 0.061998 2.08 0.063440 2.13 0.064882 2.17 0.066324 2.22 0.067765 2.27 0.069207 2.31 0.070649 2.36 0.072091 2.41 0.073533 2.46 0.074974 2.50 0.076416 2.55 0.077858 2.60 0.079300 2.64 0.080742 2.69 0.082184 2.74 0.083625 2.79 0.085067 2.83 0.086509 2.88 0.087951 2.93 0.089393 2.98 0.090834 3.02 0.092276 3.07 0.093718 3.12 0.095160 3.16 0.096602 3.21 0.098044 3.26 0.099485 3.31 0.100927 3.35 0.102369 3.40 0.103811 3.45 0.105253 3.49 0.106694 3.54 0.108136 Storage (CF) I 2387 2449 2512 2575 2638 2701 2763 2826 2889 2952 3015 3077 3140 3203 3266 3329 3391 3454 3517 3580 3643 3706 3768 3831 3894 3957 4020 4082 4145 4208 4271 4334 4396 4459 4522 4585 4648 4710 ~ Frequency 1bO Year 6-Hour Storm P6=2.7 in./hr. Outflow (cfs) I 0.0058 0.0059 0.0060 0.0060 0.0061 0.0062 0.0063 0.0063 0.0064 0.0065 0.0065 0.0066 0.0067 0.0067 0.0068 0.0069 0.0069 0.0070 0.0071 0.0071 0.0072 0.0072 0.0073 0.0074 0.0074 0.0075 0.0075 0.0076 0.0077 0.0077 0.0078 0.0083 0.0152 0.0262 0.0399 0.0557 0.0732 0.0921 0 f1-0~d H-7 Calculated by MB Date: 8/15/2019 Unit Oograph Calculation Form Project: Resort View Pipe Lookup Table I Depth (ft) I Storage (A-F) I 3.59 0.109578 3.64 0.111020 3.68 0.112462 3.73 0.113904 3.78 0.115345 3.83 0.116787 3.87 0.118229 3.92 0.119671 3.97 0.121113 4.01 0.122554 4.06 0.123996 4.11 0.125438 4.16 0.126880 4.20 0.128322 4.25 0.129764 Storage (CF) I 4773 4836 4899 4962 5024 5087 5150 5213 5276 5338 5401 5464 5527 5590 5653 0 Frequenc., i'oo Year 6-Hour Storm P6=2. 7 in./hr. 0 utflow ( cfs) I 0.1123 0.1336 0.1558 0.1788 0.2026 0.2269 0.2518 0.2772 0.3029 0.3289 0.3552 0.4164 0.5856 0.8175 1.0895 l)H-8 Calculated by MB Date: 8/15/2019 Engineering Attachment I -Hydraulic Calculations. Precast Concrete Drain Inlets: Resort View Preliminary Drainage Study There are two precast concrete drains on the project. Each one captures the runoff from the driveway in which it is located. The runoff in the driveway is approximately half of the total runoff for each drainage area. For preliminary sizing, the entire drainage area will be assumed to drain to the inlet. Overflow at the inlet in BF-2 flows to the sump pump. The inlet has the largest Ql00 peak flow at 2.6 cfs and must capture the flow and direct it to sump. The inlet is a 24" square grate and the grate is 0.50 feet below the top of the BMP. The weir equation for determining the capacity of the inlet is: Q=3Lh3l2 or h={Q/3L)2l3 Wher: L = 8' Q100 = 2.6 cfs C h =(2.6/(3*8))213 = 0.23' ✓OK Parkway Culvert: Autocad Hydraflow Express is used to determine the flow in the parkway culverts. The culvert is the outfall from the detention tank and will be sized to carry the un-mitigated peak flow in the event of a failure at the detention tank outlet. The culverts dimensions are: Width= 4.0' Height= 4" Slope= 0.02 Peak Q 100 = 4.3 cfs The results are on the following page. October 15, 2019 C:\MLB Projects\County of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx Page 1-1 Engineering Channel Report ~ EJqllH& Elllensian fer Auladftll&CMI 3DC by Aulal_._, Ille. T ANK-1 Outfall Reclangular Bottom Width (ft) Total Depth (ft) Invert Elev (ft) Slope(%) N-Value calculatlona Compute by: Known Q (cfs) Elev (ft) 68.00 67.50 87.00 86.50 86.00 0 October 15, 2019 .5 = 4.00 = 0.33 -66.70 -2.00 = 0.015 Known a = 4.30 1.5 2 Section -..~ --.. 2.5 Resort View Preliminary Drainage Study Highlighted Depth (ft) a (els) Area (sqft) Velocity (ft/s) Wetted Perim (ft) Crit Deplh, Ye (ft) Top Width (ft) EGL (ft) 3 3.5 4 Thursday, .-Ug 15 2019 = 0.23 -4.300 = 0.92 -4.67 -4.46 -0.33 -4.00 -0.57 4.5 Depth 1.30 0.80 0.30 -0.20 -0.70 5 Page 1-2 C:\MLB Projects\County of San Diego\ 17-sd400 Resort View Ca\Drainage Study\Resort View Preliminary Drainage Study.docx .:..6S.1!f!,-... 0 10 Scale: 111=10' -~ -~ #fll "" ,. ~ w ' r ;)<:, __ _ 20 Feet X " '!l X q'\ ~ x_ ~······· . ~··· ;I,\ ---w IV u X X / / / .t; / / 1-0 I , .x X, ... ");, X N QlOO = 1.4 cfs Elev c 66.2 l ,, ,z, "' "' X / ~ x: / X X X / / \ ' "IN w X f; (j 105.QO' F X ~ X X / I / / / 8 "' ,.._ -, w • I 2) ~ "' 0 "' "' 2 /IA--- >< ... /0. w 0 X X \ \ !-l r ;I, X w 0 N00° 03' 4.5"W 84.15' ;s; ' r-- X l.i___J~ · .=r::::r::.L~~--:-r:-:r:7 .. _LL I _ 1 ~-=-l--r:T7-....::r7 -----r-:r:-_l __ ~n----:-1-_.L~I ,{JI' -N, IV w ij ...... X ' ' X \ I V-! X k I l ,. w 1-:!; ho >s,IO 0 "' ro· 2 .. "" "'"" . X X' X .· / X Elev=89.3 X Notes: • Underlying Hydrologic Soils Group for the entire project is Soils Group D. • Runoff Factor per Table B-1.1 = 0.30 • There are no existing impervious areas on the site. Legend: DMA Name DMA Area DMA Impervios Cover DMA % Impervious Drainage Area Boundary DMA-0 100 SF (10 SF IMP) 0.0% IMP ------ SHEET I Engine¢ring Professional f;ivil ifngineers and Land Surveyors Attachment B1 Resort View (Viejo Castilla Way) 1 404 South Live cj)ak Park Road, Fallbrook, CA 92028 "Phone 760 731-6603 E-Mail: MLBcnc,;h@pacbcll.net Existing Condition Hydrology Map OF 1 <l '11 11-----M------M------x, ------M------M------M------M------M,,-----M------------M------M------M------M-~-----M------M------M------M---------w------w---- -----......... w -------w QlOO = 0.3 cfs (mitigated) Q100 = 4.3 cfs (unmititgated) ~ \ ,ii \ 64.5'\\ -~-1'2 ----,~ ----- ,-, ,-, ~ ' 66 '--' ,; 1: I ! ! ' ' ' I ' ' ' + "<l ' t'f''b ,+ --}ff "'+ l \ -· ,-_, ' 0 20 ~I ~~~~-~110-~~-~~l Feet Scale: 1"=10' 4 •+ "' ,+ ,+ ,+ + +" " + +- + . j . ' ' Q100 = 3. 7 cfs +-+-,,---. ,:;;D-_------··sD· .... I '0. . . . . .A.~-.. I• f'--~~-~-,_· ~-_ . ._o-,~•· -~~_,· . I: . . :,. -. : x· ... . ' '. . ·/: .. I I / ' . /' .. : -~ -~-----~~-~~--~~--+.,. .. ~~~0 : : . . : It . ·i' I >-c--~-~,_ -~~~~----! I . ,I' . I •• . , .. ------·------ .. I .. . ,/ . . : I .. / ' \ \ DM1-P-20 0.439 AC (170051SF IMP) 88.9r, IMP ' QlOO = 1.4 cfs I;; ' 70.'JO· ~ 70AB \ X --·. . r . • I •• .. /. ' 1 .. . . i ' ' i . . , .. :, .. , . .. X. T , ' i: . "/ .. . /. . • .1 · . ! . . -I : .. ( ' . : /-. .. ) : .. /' ·/ .. .. I .. •• I • ' . ( .. • 1-• "/ .. • • I • . (, . . ,,, ' . BF-1 Biofilter 2..:2-2, . X. l . : f : ' ! . ' . . ' ' ! . ' ' . 'x .. .. ) . . •\ . . "· . . .) . . . \. DMA-P-10 0.290 AC (10312 SF IMP) 81.8% IMP \ Q100 = 1.5 cfs . : ~-: .. ·...--:-· ~ ... • -s --< .. ' ' DMA-P-50 0.032 AC (1410 SF IMP) 100.0% IMP .. / .. --:--.. Q100 = 1.5 cfs '{! .. in . / rl--7 ;j, I . I ·1 . . . 0 l·-'I: "' ., . . ,-. . --- ---- Q100 = 0.1 cfs = " .'(/} Nt-----,c._~ X I J I \ . ~ ~ ' 79.8 TG 74.5 INV 1 \ :'\ \ , ' ' , X ' , , ' , ' ' ' ',~~ 12" Cone I I I Brow-Ditch TANK-1 ' 5313 cf STORAGE TANK DMA-P-60 0.062 AC (0 SF IMP) 0.0% IMP I , ' - I I /I I I J \ -: ' I : :83.4:: : : Fs: · :3(7T 75,YINV ·----' . . :x: .. ' ' • ✓!D.' -,,. r--!. ' ' . . -"'-' . :x: I "' ' 'L 76.4'.IIG 75.l INV / X I , ' / , ' ' , I I ' I i' ' I I I ! ' I ' I I I ! 'i ,_I Notes: • Underlying Hydrologic Soils Group for the entire project is Soils Group D. • Runoff Factor per Table B-1.1 = 0.30 • There are no existing impervious areas on the site. Legend: Impervious Surface (Parking, building, sidewalk) Storm Drain Drain Inlet Detention Tank Bifi/ter BMP Sump Pump Storm Drain Pressure Main DMA Name DMA Area DMA Impervios Cover DMA % Impervious Drainage Area Boundary i--s-- + + + + + + + + + + + + + + + + + + + + + + + + + -----FM----- DMA-0 100 SF (10 SF IMP) 0.0% IMP ------ SHEET Engineeting Professional C{vil .Engineers and Land Surveyors Attachment B2 Resort View (Viejo Castilla Way) 1 404 Sol1th Live Oat{ Park Road, Fallbrook, CA 92028 Phone 760 731-6603 ' E-Mail: 1\1LBencsh@pacbcll.net Proposed Condition Hydrology Map OF 1