Loading...
HomeMy WebLinkAbout5957 LANDAU CT; ; FPC2020-0174; PermitPERMIT REPORT Fire Permit Print Date: 08/30/2021 Job Address: 5957 LANDAU CT, CARLSBAD, CA 92008-8803 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel#: 2120612200 Track#: Valuation: $0.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: {"Cityof Carlsbad Permit No: FPC2020-0174 Status: Closed -Finaled Applied: 10/0S/2020 Issued: 12/02/2020 Finaled Close Out: 08/30/2021 Inspector: Final Inspection: Description: L3 HARRIS -REVISED PLANS TO INSTALL NEW VOLUNTARY FIRE ALARM SYSTEM WITH OCCUPANT NOTIFICATION (2 SYSTEMS, DEVICES) Applicant: BAY ALARM COMPANY TIM GIOUTLOS 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (858) 231-6895 FEE FIRE New Alarm System FIRE New Alarm System FIRE Plan Review (per hr -Regular Office Hours) Total Fees: $2,734.00 Total Payments To Date: Fire Department $2,734.00 FPContractor: BAY ALARM COMPANY 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (858) 586-3803 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $1,265.00 $1,265.00 $204.00 $0.00 Page 1 of 1 8205 Ronson Rd. Ste F San Diego, CA 92 111 (800) 4 70-1000 Contractor License # 880138 I. PROTECTED PREMISE 11. L3HARRJS 5957 LANDAU CT CARLSBAD, CA 92008 MONITORJNG COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-4 70-1 000 California Alarm Operating License Number: ACO28 III. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92 1 11 I (800) 4 70-1000 Contractor License # 880 138 □ a a g a a I I I C I C m I I a a I a .AUTO CALL UL, ULC Approved" 4007ES Fire Control Units 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Features Figure 1: 4007ES Panel Front View Compatible with Autocall ES Net Flexible standard combination of addressable initiation and addressable notification 4.3 in. (109 mm) Diagonal color touchscreen display: · Convenient and IntuIt1ve user interface provides detailed system status and 1nd1vIdual point information · Supports dual language selecnon, 1nclud1ng unicode character languages · A custom background display appears when operation Is normal Includes a 3 A IDNAC SLC (signaling line circuit) output power supply that provides enhanced power delivery to addressable notification appliances: · A constant 29 VDC source voltage Is maintained during alarm, even during battery operation, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby · Efficiencies include lower strobe currents, wiring distances up to two to three times farther than with conventional nouf1canon. support for more appliances per IDNAC SLC. and smaller gauge wiring. This provides 1nstallat1on and maintenance savings, with high assurance that appliances will operate as normal during worst case alarlT' conditions . IDNAC SLCs are compatible With both TrueAlert ES and TrueAlerr addressable notification appliances, and remote 4009 IDNAC Repeaters to extend power and wiring distance even farther and provide for up to 127 addressable nor1f1cat1on appliances · Power supply provides battery backup charging of up to 33 Ah: up to 18 Ah for cabinet mounted batteries and up to 33 Ah batteries for mounting In close-nippled remote battery cabinet Electrically isolated ID Net+ addressable initiating device SLC: · Provides built In short rncuu 1solanon for monitoring and control of TrueAlarm analog sensors and IDNet communications dev1ees: for use with e1rher shielded or unshielded, twisted or untwisted single pair wiring; outpurs are Class A or Class B · Standard panel SLC provides up to 100 addressable points; opuonal add1t1onal loop expansion modules provide an add1nonal isolated loop • Atl lt11 t h t1r ,. with short circuit isolation for the IDNet+ channel; each loop expansion module also provides an additional 75 addressable points to the IDNet + channel capacity for a total of up to 250 addressable points Software Feature Summary: · Current and previous panel configurarion are both maintained in on- board memory to allow easy selewon of desired revision · An internal Ethernet service port Is available for service computer connections to perform configuration updates, downloads and uploads: report downloads, and system software updates · Internal USB interface allows a memory stick/thumb drive to store Job revIsIons, update revised Jobs and panel software, and save detailed system reports from the panel Optional modules and connections include: · Fire Alarm Nerwork Interface Card for ES Net · Peer-co-Peer network communications, supports either Class B or Class X operanon · Point or Event DACT assembly that Is compatible with IP Communicarors · Up to two additional IDNet+ addressable device output loop connernons with 75 addit1onal point caparny each · Front mounted 48 LED annunciator with custom label inserts. · Dual Class A IDNAC Isolator (DCAI) · Remote LED annunciator support through RUI (remote unit interface) communications port for use with unshielded, twisted pair wiring (UTP) · Eight Point Zone/Relay Modules 1nd1v1dually selectable as IDC or relay rated 2 A@ 30 VDC (resistive) · Alarm relays and auxiliary relays · Dual RS-232 ports (for printer, PC annunciator or rh1rd party interface) · Truelns1ghr Remote Gateway · Ciry connernons, with or without disconnect sw1rch · 4003EC Voice Control Panels · 4009 Series IDNAC Repearers · Banery brackets for seismic area protect1on General Mechanical: · Compacr red or platinum cabinet for convenient surface or semi-flush mounrIng rared NEMA 1 and IP30 4007ES Listings reference: · UL 864 Control Units, Sysrem (UOJZ): Conrrol Unit Accessories, System, Fire Alarm (UOXX); Control Units. Releasing Device Service (SYZV) · UL 2017 -Emergency Alarm System Conrrol Units (CO detewon), (FSZI) · ULC S559 Central Station Fire Alarm Sysrem Units (DAYRC) · ULC-S527 -Control Unns, Sysrem, Fire Alarm (UOJZC); Conrrol unir Accessories. System Fire Alarm (UOXXC); Conrrol Units. Releasing Device Service (SYZVC) AC4007-0002 Rev 14 1112019 ~AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Introduction 4007ES Series Fire Detection and Control Units 4007ES panels provide extensive installation, operator, and service features with point and module capacItIes suitable for a wide range of system applicat1ons. Panels can be configured for stand-alone or networked fire conrrol operation. The convenient and intu1t1ve color touchscreen provides easy access for typical system response actions and for detailed system review or configuration updates with password conrrol to hm1t user access. IDNet+ addressable Inrt1at1on communrcat1ons and IDNAC addressable notification communications are standard features. (Refer to data sheet AC4007-0001 for 4007ES panels providing conventional notification.) ES panel compatibility with ES Net Autocall ES Network (ES Net) Is a next generation IP based fire network that uses industry standard network technology and infrastructure and allows for simplified network upgrades, easy terminal connectIvIty and IP file transfer between nodes; and advanced network diagnostics. ES fire alarm control units can be upgraded to operate on an ES network by adding an ES Net NIC to the panel. For more detailed 1nformat1on on ES Net, consult datasheet AC4100-0076, and talk to your local Autocall product supplier Operator Interface Convenient Status Information With the locking door closed, the glass window allows viewing of the display status LEDs The user 1nrerface Is a 4.3 In. diagonal color touchscreen LCD with separate status LEDs as shown below LED 1nd1cators descnbe the general category of actIvIty being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control funcnons and allows further InquIry by scrolling the display for add1t1onal detail Touchscreen Display with LED Status Indicators Figure 2: Touchscreen Display with LED Status Indicators Page 2 Operator Screen Reference Main Menu Screen provides easy navIgauon to the function required Buttons A, B, and C have programmable functions. System Trouble Screen identifies acnve troubles with custom labels displayed, arrows allow navigation through the list. System Alarm Screen 1denr1fies active alarms with custom labels displayed, arrows allow navigation through the list. Trouble Log Screen allows review of past troubles with time stamp and point details shown. --____ ._ .... -------···----If --· -- Point Information Screen allows User Access Login Screen review of point details, arrows allow controls access to panel operations navIgat1on through the information. as determined per panel. Operator Interface and Software Features · Convenient and detailed operator information Is easily accessed using a logical, menu-driven touchscreen display with password access control , Multiple automatic and manual diagnostics for maintenance reduction · Alarm and Trouble History Logs (up to 1000 entnes for each, 2000 total events) are available for vIewIng from the display or for prinnng to a connected printer, or downloaded to a service computer · Module level ground fault searching assists installation and service by locat1ng and 1solat1ng modules with grounded wiring · WALKTEST silent or audible system test performs an automatic self- resemng test cycle and supports up to eight WALKTEST groups · Install Mode allows grouping of multiple troubles for un1nstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped Inro a single trouble, operators can more clearly 1denrify events from the commissioned and occupied areas AC4007-0002 Rev. 14 11/2019 ~AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Not1ficat1on Mechanical Description · Locking door with polycarbonate window · Latching from panel assembly swings forward for convenient internal access · Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required · Modules are power-l1m1ted (except as noted, such as relay modules) · Battery compartment (bottom) accepts two batteries, up to 18 Ah, to be mounted within the cabinet without interfering with module space; charger caparny Is up to 33 Ah; for batteries greater than 18 Ah, refer rn Module and Accessories Select1or-Information for external battery cabinet details · Cabinet assembly design has been seIsmIc tested and Is cerufied to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet AC2081-0019 IDNet+ Addressable Device Control The 4007ES Hybrid provides an IDNet+ addressable InItIa11ng device Signaling Line Circuit (SLC) that supervises wiring connernons and the individual device communications status on the SLC. With two-wire IDNet+ SLCs, inItIatIon, monitoring, and control devices such as manual fire alarm stations, TrueAlarm sensors, control relays, and sprinkler waterflow switches can communicate their 1dent1ty and status and receive ftre alarm system control Add1ttonal addressable interface modules include rncuIt isolators, conventional IDC zone adapters, and interface to other system rncuIts such as fans. dampers, ano elevator controls. IDNet+ Addressable Device Operation Each addressable device on the IDNet+ communtCatton channel Is conttnuously interrogated for status cond1t1on such as normal, off-normal. alarm, supervisory, or trouble. Both Class Band Class A operatton Is available Soph1st1cated poll and response communication techniques ensure supervIsIon Integmy and allow for ''T-tapp1ng·· of the circuits for Class B operation. Devices with LEDs pulse the LED rn 1ndtCate receipt of a communications poll and can be turned on steady from the panel With addressable devices, the locat1on and status of the connected devtCe Is monitored, logged, and displayed on the operacor interface LCD with each device having its own 40 character cusrnm label for precise 1dent1ficat1on. TrueAlarm Addressable sensor operation Addressable Iniuating device communications include operauon of TrueAlarm smoke and temperature sensors. Smoke sensors transmn an output value based on their smoke chamber cond1t1on and the CPU maInraIns a current value, peak value, and an average value for each sensor Status Is determined by comparing the current sensor value to its average value Tracking this average value as a con11nuously sh1fung reference point filters out environmental factors that cause shifts In sensIttvIty. Figure 3: TrueAlarm Photo Sensor with Base Programmable sensitivity Figure 4: TrueAlarm Photo/ Heat Sensor in CO Base Programmable sensmvIty of each sensor can be selected at the control panel for different levels of smoke obscurauon (shown d1renly in percent) or for specific heat detectton levels. To evaluate whether the sensIttvIty should be revised, the peak value Is stored In memory and can Page 3 be eastly read (or downloaded as a report) and compared to the alarm threshold directly in percent. CO sensor bases CO sensor bases combine an electrolyltc CO sensing module with a TrueAlarm analog sensor to provide a single mult1ple sensing assembly using one system address. The CO sensor can be enabled/disabled. and can be used In LED/Switch modes and custom control. Refer to AC4098-0052 for more details. TrueAlarm heat sensors TrueAlarm heat sensors can be selected for fixed temperature detectton, with or without rate-of-rise detectton. Utility temperature sensing Is also available, typically to provide freeze warnings or alert to HVAC system problems. Readings can selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection Multi-sensor A4098-9754 provides photoelectrtc and heat sensor data using a single 40070ES IDNet+ address. The panel evaluates smoke act1vIty, heat actIvIty, and their combination, to provide TrueSense early detection. For more details on this operanon. refer to data sheet AC4098-0024 Diagnostics and Default Device Type Sensor Status TrueAlarm operatton allows the control panel to automatically indteate when a sensor Is almost dirty. dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensiltvIty range of the sensors is fulfilled by the ability of TrueAlarm operatton co maintain the sensIltvIty level of each sensor CO Sensors rrack their 1 O year arnve life status prov1d1ng 1nd1cators to assist with service planning. Indicators occur at 1 year, 6 months. and end of ltfe Modular TrueAlarm sensors TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific locat1or requirements. This allows 1ntenltonal sensor subsmut1on during bu1ld1ng construrnon when cond1t1ons are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled). heat sensors may be installed without reprogramming the control panel The control panel will 1nd1cate an incorrect sensor type, but the heat sensor will operate at a default sensItIvIty to provide heat detection for building proternon at that locanon. IDNet+ Addressable Channel Capacity The 4007ES Hybrid provides an isolated output IDNet+ signaling line circuit (SLC) that supports up to 250 addressable monitor and control poInrs 1nrerm1xed on the same pair of wires. (250 rntal requires two A007-9803 IDNet+ Loop Expansion Modules.) Table 1: IDNet+ SLC Wiring Specifications Specification ,Rating Maximum Distance Oto 125 4000 ft (12 19 m)· 50 ohms from Control Panel per 126 to 2500 ft (762 m): 35 ohms Device Load 250 Total Wire Length Allowed With Up to 12500 ft (3_8 km); 0.60 µF "T" Taps for Class B Wiring Maximum Capacitance Between IDNet+ Channels Loading per device Wire Type and Connections 1 µF 0.8 n1A supv. 1 mA alarm; 2 mA per activated device LED Shielded or unshielded twisted or u ntw1sted wI re* AC4007-0002 Rev 14 11/2019 ~AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Table 1: ID Net+ SLC Wiring Specifications Specification Rating Connections Terminal blocks for 18 to 12 AWG Compat1brl1ty includes: IONet communicating devices and TrueAlarm sensors including QuickConnect and Qu1ckConnect2 sensors Note: * Some applications may require shielded wiring. Review your system with your local Autocall product supplier. IDNAC SLC Control of TrueAlert and TrueAlert ES Addressable Notification Addressable notification appliance communications Addressable not1ficat1on appliance communications include operation of TrueAlen and TrueAlen ES Visible only (V/O, strobe), Audible only (A/O, horn), Aud1bleNis1ble (A/V, horn/strobe), and strobes of SpeakerNis1ble (SN) not1f1cat1on appliances. (S/V appliances require separate speaker wiring.) IONAC SLC addressable communications allow each horn and strobe to be 1nd1vidually controlled using a single two-wire circuit. confirms the wiring connections ta the individual notification appliance's electronic circuit, and confirms communications between each appliance and the fire alarm control unit. Addressable communications increases supervIsIon integrity versus conventional notification systems by providing supervision beyond the cIrcuIt wiring to each 1ndiv1dual appliance and by constantly verifying the ability of each appliance to communicate with the control panel. Individual Appliance Status and Settings The fire alarm control unit monitors and records each addressable not1f1cat1on appliance status, type of appliance. and its configured appliance semngs A fault In any 1nd1v1dual appliance automatically reports a trouble cond1non to the control panel """"'" VK.J1troN A/Yhou\lsttd>~ Figure 5: TrueAlert ES Addressable Appliance Reference Virtual NACs Provide Control Convenience For control convenience. IDNAC notification appliances can be grouped into Virtual NACS (VNACs) for group control. Panel Control Convenience Applicable operanon semngs for each appliance can be programmed without having to replace appliances or remove them from the wall or ceding. An appliance's VNAC notif1canon zone can be easily changed through programming without having to add additional cIrcuI1s, conduit. and wiring. Audible and visible appliances for non-fire emergency communications not1f1cat1on can be programmed to operate separately on the same pair of wires as the fire alarm notification appliances. The result Is lower installation, retrofit, and overall life-cycle cost of ownership compared with tradmonal convennonal notificauon systems. Installation, Retrofit, and Life-Cycle Cost Benefits With each addressable appliance capable of being controlled separately on the same two-wire IDNAC SLC installation t1n1e and expense for both retrofit and new construcuon can be significantly reduced When Class B wiring Is used, wiring can be "T tapped" allowing more savings In distance. wire, conduit (size and utll1zanon). and overall 1nstallat1on efficiency Location Information, Diagnostics and Troubleshooting Each addressable not1f1canon appliance has its own 40 character custom label to 1dent1fy the locauon of the appliance and to aid In troubleshooting fault cond1t1ons. In convenuonal nonf1canon systems. conventional appliances are not capable of communicating wnh the Page 4 control panel. Fault reporting on a conventional system Is limited to the circuit wiring and the ennre area (zone) covered by appliances on the notification appliance circuit (NAC) making it much more difficult and costly to locate and correct the source of a problem. Using the TrueAlert magnet test allows each appliance to 1nd1v1dually 1dent1fy its candela setting and address and to briefly operate 1f desired, and using the TrueAlert ES Appliance Self Test feature provides detailed performance verification per appliance. TrueAlert ES Appliance Self-Test Operation On-Board Test Sensors TrueAlert ES appliances are equipped with on-board sensors to detect strobe and/or horn output allowing efficient and unobtrusive Self Tesnng. When Automatic Self-Test Is initiated from the control panel. each appliance within the selected VNAC group will briefly operate and then report its Self-Test status to the control panel, all within several seconds. Silent Self-Test can be selected to test only visible appliance 1f desired. The control panel is In a trouble condition during resting and In the event of an alarm, Self-Test is automat1cally terminated. Automatic Self-Test Results are communicated to the control panel with a time and date stamp and are stored in memory. Results are viewable at the front panel display and printed reports are available from the panel USS port. Individual Self-Test Self-Test Is selected from the control panel when 1nd1v1dual appliances need to be observed to operate Each appliance In the selected VNAC group will turn on its LEO until 1nd1v1dually activated by applying a magnet. After performing the 1nd1v1dual rest, the appliance LED turns off to 1nd1cate completion. Results are recorded the same as during the automatic test IDNAC SLC Hardware Reference The 4007ES provides a 3 A IONAC SLC for control and power to TrueAlen ES and TrueAlen addressable not1ficat1on appliances. The power supply incorporates an efficient switching design that provides a regulated output of 29 VDC. even during battery operation With 29 voe minimum output at the panel. addressable not1f1cat1on SLCs can support wInng distances two to three times farther than available with conventional notification, or support more appliances per SLC. or work with smaller gauge wiring. or combinat1ons of these benefits. The result Is installat1on and maintenance savings with high assurance that appliances chat operate during normal system tesnng will operate during worst case alarm conditions. IDNAC SLC Appliance Wiring Reference IDNAC SLC Capacity Up to 127 addresses and up to 139 unit loads (appliances are typically one unit load. devices such as Isolators may require more than one load, refer to ind1v1dual dev1Ce data sheet for specific 1nformanon Table 2: IDNAC SLC Appliance Wiring Reference Wiring Reference Description Recommended Wire Type UTP, unshielded twisted pair Maximum wire length allowed with "T-Taps' for Class B wiring, per SLC 1 O.OOO ft (3o43 m) Maximum wire length per SLC to any appliance 4000 ft ( 1 219 m) Appliance Supervisory Current Wiring Connections 1 unit load = 0.8 mA per appliance Terminals for 18 to 12 AWG AC4007-0002 Rev 1411/2019 -AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification 4007ES Mounting and Module Location Reference Key A B C D E F G H K L M 20.7/8" (530 mm) 20-3/16· (512mm) Finished wall surface (including serni•fkJ&h Tnm Kil If U&ed) Ellposed box !or se,.,.._flUsh mount,rig 1-3/4" (44 mm) mtnlmtm 4-7/16" Deep (112 mml Table 3: Module locations Description CPU and User Interface assembly Location for optional A007 9805 LED Module Power Supply Assembly. A007-9806 SDACT location. Note: The SDACT includes a 650-1838 nat mounting bracke: (available separately). Some pre-existing systems with an angled SDACT bracket will need to be replaced with rhe flar mounr,ng bracket when a Network Interface Card ,s installed Location for A007-9801 Zone/Relay Module A007-9812 Dual RS-232 Interface, or (as shown) A007 9802 25 V Regulator Module Primary location for A007 9801 Zone/Relay Module Location for addtt1onal A007-9801 Zone/Relay Module. ldenncal to Block G above A007-9807 or A007-9808 City Circuit Module, or A007-9809 Relay Module. A007-9803 IDNet➔ Loop Expansion Modules, maximum of two (two are shown). Identical to block J above. Bloch L 1s an add111onal block that sirs or spacers above Block G and H The A007-9810 or A007-9817 NIC can be mounted tn block L with or without modules mounted below 1t ,n blocks G and H When fiber media cards are used and an SDACT ,s present, the SDACT requires a 650-1838 Oat mounting bracket (ordered separately) Battery locatton for up to 18 Ah batteries. Note: No conduit entry or wiring ,n this area. 14 7/8 w (378 mm) wide. Note: A system ground must be provided for Earth Detectron and transient protection devices. This connectron shall be made roan approved. dedt cated Earth connection per NFPA 70. Anrcle 250, and NFPA 780. Page 5 AC4007-0002 Rev. 14 11/2019 -AUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Power Supply Output and Zone/Relay Module Details Power Supply Output Details: · 2 A Auxiliary Output (AUX/SNAC) can be selected either as resettable auxiliary power of 2 A@ 24 VDC, or selected to be a simple NAC (SNAC) for sounder base power. four-wire detector power. or door holder power · 4 A Output Rating. This includes current for IDNAC controlled nonfication appliances; IDNet devices; module currents; and auxiliary output current (battery charging, CPU, and power supply current are not subtracted from the 4 A) · Low Battery Voltage Cutout Is selectable when required (required for ULC listing applications) · Battery and Charger Monitoring includes battery charger status and low or depleted battery cond111ons; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and IDNAC SLC current · Battery Charger Is dual rate, temperature compensated, and charges up to 18 Ah sealed lead-acid batteries In the battery compartment, and charges up to 33 Ah batteries In an external cabinet · ID Net+ SLC Output provides electrically isolated Class B or Class A communicanon; standard caparny is up to 100 addressable points with expansion for up to 250 points using up to two A007-9803 IDNet+ Loop Expansion Modules (see IDNet+ Addressable Channel Caparny) · Compatible RUI remote equipment includes: A4606-9202 and A4606-9205 Color Touchscreen Annunciators (up to 6 total), 4100 Series 24 1/0 and LED/Switch modules, A602 Series LED/Switch and 1/0 Annunciator modules, including A602-9101 Status Command Units (SCU), and A602-9102 Remore Command Units (RCU) · RUI Communications controls up to 10 remote devices at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wInng is Class Band T- rapped; output Is selectable as Class B or Class A Product Selection Model A007-9201 A007-9202 Color Red Table 4: Product Selection Description Supv. 4007ES with a 3 A, Class 8, IDNAC SLC for up to 127 addressable notification appliances, and 4 A output power supply/battery charger; includes ID Net+ communicanons for 100 addressable points Note: Add opnonal module and other currents separately for battery calculanons; base panel current does not subtract from the 4 A power available for optional mod- ules and external loads 180mA Module and Accessories Selection Information Model A007-8810 SKU A007-9801 A007-9802 A007-9803 A007-9804 Table 5: Factory Programming Options Description Factory Programming (select) Table 6: Field Installed Optional Modules Description Eight Point Zone/Relay Module; each point is selectable as an IDC input or Relay output Class A IDCs require two points (one out and one return); select up to four maximum. Alarm current shown Is for eight Class B IDCs using 3.3K end-of-line- Supv. resIstors with four IDCs In alarm and four IDCs In standby. Supervisory current shown 83 mA max Is for all eight IDCs In standby Detector current Is added separately. Refer to 4007ES Hybrid data sheet AC4007-000 7 and 579-1103AC Zone/Relay Module Installation Instructions for additional information. 25 voe Regulator Module; 2 A maximum output: with 1 module use to power Zone/Relay modules connecteo to 1nit1ating devices requiring nominal 25 VDC voltage refer to technical publ1canon 579-832AC 2-W,re Detector Compat1b11ity Chan for applicauon ceta1ls with 2 modules with 3 modules IDNet+ Loop Expansion Module: provides an add1t1onal isolated loop with short rncun isolation to the exIsung ID Net+ channel, also :irov1des an additional 75 addressable points to the IDNet• channel capacity, maximum of two Dual Class A IDNAC Isolator (DCAI); converts a single Class B IDNAC SLC input to two Class A or rwo Class B SLC outputs. provides short rncuIt isolation between each Class A or B output cIrcuIt. requires one IDNAC address; rhe total current remains controlled by the Class B input source SLC at 3 A maximJm maximum 30 appliances per isolated 190 mA 290 mA 390 mA NA loop 12.7 mA Note: Up to 30 additional device addresses riay be installed between each A4905-9929 TrueAlert Addressable Isolator+ Module, not to exceed the maximum address and unn loading specifications for the IDNAC channel. Alarm 185 mA Alarm 295 mA max 445 mA 801 mA 1156 mA NA 25 mA Page 6 AC4007 0002 Rev. 14 1112019 SKU A007-9805 A007-9806 A007-9807 A007-9808 A007-9809 A007-9812 SKU A007-9817 A007-6308 A00H309 A007-6307 ~AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Table 6: Field Installed Optional Modules Description Panel Mounted 48 LED Status Annunciator Module; provides no LEDs on 24 Yellow LEDs, 20 Red LEDs, and four Red/Green LEDs that are programmable for up to 24 IDC zones of alarm and trouble with LEDs on annunciation, or as required for custom annuncIat1on requirements SDACT Module for Point or Event Reporting; order connernon cables as required (see cable details under accessories). City Circuit Module with Disconnect Switch City C1rcu1t Module without Disconnect Switch Relay Module; relays for Alarm, Supervisory, and Trouble; rated 2 A res1st1ve@ 32 VDC Dual RS-232 Interface Module, compatible with Autocall remote printer, PC annunciator or third parry interface (two ports/connections maximum) Table 7: Field Installed Optional Network Modules Supv. Alarm 10mA 10 mA 1 75 mA per LED, 105 mA max 30mA 40mA 20mA 36mA 20 mA 36mA 15 mA 37 mA 60mA 60 mA -------------Size Alarm/Supv. Card type Flat Description Connects a 4007ES FACU to an ES network. Supports Class B or Class X operation. Includes four built In Ethernet ports, supports up to two additional media cards. Ports A a1d C can be configured for earth fault deternon. Select per network connewon requirements; mounts on the supplied ES Net NICs; two media cards per slot type and flat type NIC ES Net NIC Dual Channel Single-mode Fiber Media Card Dual Channel Media Cards provide two ports for input and output ES Net NIC Dual Channel connewons Muln-mode Fiber Media Card ES Net NIC Dual Channel DSL Media Card Field connernons require proper port pairing, refer to 579-1258AC ES Net Dual Channel Fiber, Ethernet, and DSL Media Card Installation Instructions for add1t1onal 1nformat1on. 2 vertical blocks 120 mA (only In Block L) NIA 135 mA NIA 135 mA NIA 155 mA Network Interface and Network Media Card Product Selection 4007ES fire alarm control units are compatible with Autocall ES Net network · Refer to datasheet AC4100-0076 for additional 1nformat100 on compatible ES Net fire alarm products · Refer to datasheet AC4100-0061 for addmonal information on the Building Network Interface Card Model 2081-9272 2081-9274 2081-9275 2081 -9271 ISKU -- A009 9801 4009-9802 SKU A2975-9812 A2975-9813 A4081-9018 Page 7 Capacity 6.2Ah l0Ah 18Ah 33Ah Color Capacity Beige For up to 25 Ah batteries Beige For up to 33 Ah batteries Description Table 8: Batteries Battery Mounting Details 12 V Batteries for cabinet mounnng; select one battery model per system standby requirements; order quantity of two: to be wired in series for 24 voe For remote mount in Battery Box 4009-9802 Batteries for remote mounung. see battery cabinet derails below Table 9: Battery Accessories Dimensions 16 114 in. W x 13 112 In H x 5 3/4 in. D (413 mm x 343 mm x 146 mm) 25 3/4 ,n W x 20 3/4 ,n H , 4 1 /8 in. D (654 mm x 527 mm x 1 05 mm) Table 10: Accessories Description External battery cabinet without charger, wrth locking solrd door and battery harness; for close- nippled mounnng to frre alarm control unit cabinet Red semr flush box trim; 1 7116 rn. (37 mm) wrde, four corners and rrrm pieces for top, bottom, and sides Platinum semr-flush box trrm 1 7116 rn. (37 mm) wide, four corners and rrrm pieces for top, bottom. and srdes 1 0 kO, 1 w end-of-lrne resistor harness for non-addressable NACs (if A007 9801 Is used) AC4007-0002 Rev. 14 1112019 ~AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification General Specifications Specification Input Power 4007ES Power Supply Output Ratings Table 11: General Specifications Rating 120 VAC Input 2 A maximum@ 102 to 132 VAC, 50/60 Hz 240 VAC Input 1 A maximum@ 204 to 264 VAC, 50/60 Hz Battery 6 A maximum@ 24 VDC (during battery operation) 4 A output for "Special Application" appliances Power Supply Output Rating IDNAC SLC Ratings IDNAC SLC Wiring Note: The 4 A output rating was determined such that optional module currents, and external device and appliance currents can be directly added together, not to exceed 4 A total. 3 A, regulated 29 VDC during Alarm, 127 addresses, 139 unit loads; DC-DC converter cIrcuIt Is >92% efficient over operating range Output terminals are rated for 18 to 12 AWG with duplicate output terminals rated for two wires each, allowing up to four (4) Class B branch circuit T-taps to be made in the cabinet additional T-taps may be made in external wiring Juncnon cabinets or boxes 2 A maximum, 24 VDC nominal (19.5 to 31.1 VDC) Output switches to battery backup during mains AC failure or brownout condmons Auxiliary Power Tap Compatible Special Application Appliances Auwcall TrueAlert ES and TrueAlert addressable notification appliances; contact your Aut0call product representative for compatible appliances Battery Charger Battery capacity range Ratings (sealed UL and ULC listed for battery charging of 6.2 Ah up to 33 Ah (baneries larger than 18 Ah require a remote battery cabinet) lead-acid batteries) Charger characteristics and performance Temperature compensated, dJal rate, recharges depleted batteries within 48 hours per UL Standard 864; to 70% caparny in 12 hours per ULC Standard S527 Supported file types. JPG, BMP, GIF, and PNG Custom Background Display Details Recommended image type is,PG, recommended image size Is 480 x 240, and the file size limit Is 100kb Operating Temperature 32°F to 120°F (0°C to 49°() Environmental Operating Humidity Up to 93% RH, non-condensing@ 90°F (32°() maximum 4007ES and Network Product Reference Table 12: Additional 4007ES and network product reference [subject Serial DACT (SDACT) for 41 00ES, 401 DES, 4007ES Se1sm1c Battery Brackets Reference 4007ES Panels with Conventional Nottf1cat1on 4007ES Extinguishing Release Applicat1ons 4009 IDNet NAC Extender 4009 IDNAC Repeater External 110 Ah Battery Charger for 41 00ES, 401 DES Graphic 1/0 Modules for 4100ES, 401 0ES. 4007ES Interface m VESDA Air Asp1rat1on Detection Systems lnfoAlarm Command Center with SPS Power Supplies BACpac Ethernet Module Building Network Interface Card (BNIC) ES Net Network Products and Spec1f1car1ons NDU with 5PS Power Supplies for ES Net lnfoAlarm Command Center with EPS Power Supplies NDU with EPS Power Supplies for ES Net PC Annunc1at0r TrueS1te Workstation TrueS1te Incident Commander SCU/RCU Annunciators A4606 Series Color Touchscreen LCD Annunciators Page 8 Datasheet AC2080-0009 AC2081-0019 AC4007-0001 AC4007-0003 AC4009-0002 A.(4009-0004 AC4081-0002 AC4100-0005 AC4100-0026 AC4100-0045 AC4100-0051 AC4100-0061 AC4100-0076 AC4100-0077 AC4100-0101 AC4100-0104 AC4190-0013 AC4190-0016 AC4190-0020 AC4602-0001 AC4606-0003 AC4007-0002 Rev 14 11/2019 -AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification 4007ES Additional Reference Figure 6: 4007ES with IDNAC Notification and optional 48 LED Annunciator Module (A007-9805) TrueAlert ES appliance self-test last test results report example service Port Figure 7: A4606-9205 (Platinum) Color LCD Touchscreen Remote Annunciator Figure 8: A4606-9202 (Red) Color LCD Touchscreen Remote Annunciator Page 1 REPORT 10 TrueAlertES Self-Test Report 12:34 :56pm MON 0l-JUN-15 Point ID custom Label Date Tl-1-1 VO FIRST FLOOR (up to 40 characters) 0l-JUN-15 Tl-2-5 AV FIRST FLOOR EAST WING 0l-JUN-15 T7-3-55 AO SECOND FLOOR EAST WING 0l-JUN-15 TB-2-45 AV SECOND FLOOR ROOM 29 0l-JUN-15 TB-2-60 AV SECOND FLOOR ROOM 22 0l-JUN-15 Tl-2-4 AO FIRST FLOOR ROOM 17 0l -JUN-15 TRUEALERT ES SELF-TEST REPORT COMPLETED - Press RETURN for next Screen OR CTRL-X t o abort Figure 9: Reports example Results Description: NORMAL= works correctly NO OUT= No Output, no light or sound was detected Visual Audible NO OUT N/A NO OUT NORMAL N/A NO OUT NOT TST N/A NORMAL NORMAL N/A UNSUPP NOT TST = no result, either the appliance did not return a result before the test ended or the test was conducted as silent (strobes only) acid audible appliance was not activated NIA = not applicable (no strobe on audible only, etc.) UNSUPP = appliance not compatible with Self-Test (TrueAlert addressable appliance not TrueAlert ES addressable appliance) Note: Add1t1onal TrueAlert ES Self Test 1nformat1on is detailed 1n Operating Instructions 579-1165AC shipped with the panel Page 9 AC4007 0002 Rev 14 1112019 -AUTO CALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification TrueAlert ES Appliance Self-Test All Test Results Report Example Service Port REPORT 10 TrueAlertES self -Test Report 12 :34:56pm Point ID Custom Label Date Visual Tl-1-1 VO FIRST FLOOR 0l-JUN-15 NO OUT Tl-2-5 AV FIRST FLOOR EAST WING 01-JUN-15 NO OUT Tl-2-6 AV FIRST FLOOR NORTH ENTRANCE 12-MAY-15 NO OUT T7-3-55 AO SECOND FLOOR EAST WING 01-JUN-15 NIA TS-2-45 AV SECOND FLOOR ROOM 29 0l -JUN-15 NOT TST Tl-1-11 AV FIRST FLOOR SOUTH ENTRANCE 12-MAY-15 NORMAL TS-2-60 AV SECOND FLOOR ROOM 22 0l -JUN-15 NORMAL Tl-2-4 AO FIRST FLOOR ROOM 17 0l -JUN-15 NIA Tl-2-7 AO FIRST FLOOR ROOM 12 12-MAY-15 NIA TS-3-4 3 AV SECOND FLOOR ROOM 25 12-MAY-15 UNSUPP TRUEALERT ES SELF-TEST REPORT CCMPLETED Press RETURN for next Screen OR CTRL-X to abort Figure 10: Report example TrueAlert ES Appliance Self-Test Individual Appliance Report Example CUSTOM LABEL 4-1-2 POINT ADDRESS: 4-1-2 CARD: 4 CHANNEL: 1 DEVICE: 2 EXTENDED POWER SUPPLY UNIT NUMBER: 2 PRIMARY STATUS AUDIBLE GROUP CONFIG: VISUAL GROUP CONFIG: STYLE: OPERATION : CANDELA RATING COLOR LENS TON E TYPE CODING TYPE VOLUME LAST TEST TIME: LAST VISUAL TEST LAST AUDIBLE TEST: LAST TEST VOLUME: DEVICE TEST TR OUBLE: AV Type: AV RUI NUMBER: LOCAL NORMAL 00 0 0 00 INDOO R GENERALEVAC 15 CD YES BROADBAND TEMPORAL HIGH MON 01-JUN-15 01 00 AM NORMAL NOR MAL NOR MAL NORMAL Figure 11: Report exam pie Page 1 MON 0l-JUN-15 Audible NIA NORMAL NORMAL NO OUT NI A NORMAL NORMAL UNSUPP UN SUPP UNSUPP <r.. 2019 Jorrson Controls. All rights reserved All spec1f1cat1ors and otrer 1f'forrrauor srowr werf: current as of docurrert rev,s,or and are SJbJect to change without ro!lce Addl!lonal l1Slings rray be applicable. contact yoJr local AJtocall prod Jct SJppher for the latest status Listings and approvals Jnder Tyco =,re & SecJnty Grrb>-<. and tre prodJCt narres listed ,n this niatenal are niarks and/or registered marks. UraJtromed JSe ,s strictly proh1b1ted. \FPA 72 and \at,onal =,re Alarrr Code are registered traderrarks of the \auoral Fire Protewor Assooat,or (VPA) AC4007-0002 Rev 14 11/2019 .AUTO CALL UL, ULC Approved· System Accessories Panel Mounted Digital Alarm Communicat ing Transmitters with Serial Communications (SDACT) Features UL 864 listed per NFPA 72, National Fire Alarm and Signaling Code, for Central Station Service: · Operat1on Is listed to UL Standard 1459 Telephone Equipment · Registered to FCC Part 68 Dual telephone line interface: · Requires Data Certified POTS lines · Also compatible with DACT to Ethernet connection interfaces (refer to SDACT DACR Compa11bil1ty Reference) Mounts internally to Autocall models: · 4007ES, 401 0ES, and 41 GOES · For Network appilcat1ons, select a 41 00ES node for Network SDACT status reporting when available Provides specific building event information: · Communicates point status changes, phone hne status, and other off normal information · Reports up to ten events per phone call Provides programmable control for: · Automatic 6 hour test · Power fail report delay SDACT status indicators include: · Panel LCD indicates off-normal status · Module LEDs provide service diagnostics Description Serial DACT. Autocall serial digital alarm communicating transmIner (SDACT) modules monitor the status of the host fire alarm control panel and its connections to the Central Station monitoring locat1on. When status changes require informat1on to be reported, the SDACT provides detailed messages that can assist the Central Station In accurately 1mplement1ng the required response Typical information reports include alarms, troubles, and supervisory cond1t1ons. Model series 4007ES, 401 0ES, and 41 GOES provide spec1f1c point information. SDACT modules directly communicates with the fire alarm control panel CPU and are custom programmed for the specific requirements of the Central Station and the connected fire alarm control panel Central Station message with~ customer location and action ~ Central Station Monitoring Service list per application requirement Dual telephone line connections Fire Alarm Control Panel (4100ES Shown for Reference) Figure 1: SDACT Application Diagram Available Reporting Formats Local "house" telephone Contact ID (CID). CID Is the preferred format for SDACT operation It provides a four d1g11 account code followed by a three d1g11 event code, a two (hex) d1g1t group number, and a three (hex) d1g1t contact number, all of which are used to encode specific point 1dent1f1cation. 3/1 Pulse. A three d1g11 account code followed by a one d1g1t reporting code. Transmissions are sent as a double round at a rate of 20 PPS (pulses per second). Reporting codes are programmable 4/2 Pulse. S1m1lar to 3/1 except for a four d1g11 account code and a two d1g11 reporting code. Transmission Is sent as a double round at 20 PPS. Report codes are programmable. BFSK. Three d1g1rs of account code and two d1g1ts of reporting code In a single transmission of constant tones. The format has built in error checking so that a double round Is not required. Reporting codes are fixed SIA. Security Industry Assoc1at1on (SIA) D1g11al Communicauon Standard The SDACT provides level 1 compat1b1l1ty which includes tonal acknowledge, basic reports only, and fixed reporting codes. AC2080-0009 Rev. 7 712016 -AUTOCALL Panel Mounted Digital Alarm Communicating Transmitters with Serial Communications (SDACT) SDACT Product Selection and Reference SKU Fire Alarm Control Panel A100-6052 4100ES A100-6080 41 00ES with EPS A010-9912 4010ES A007-9806 4007ES Specifications Specification Voltage Current Point Capaoty 41 00ES SDACT Capacity Operating Temperature Operaung Hum1d1ty Requirement FCC Reg1strat1on Jack Connewon Type Page 2 Table 1: SDACT Product Selection and Reference Mounting Location Panel Data Sheet Reference Single 2" slot module AC4100-0031 Left side of CPU bay end support or left AC4100-0100 side of an expansion bay Block D AC4010-0004 Lower right corner of cabinet mounted flat with included 650-1838 mounting AC4007-0001 bracket Table 2: General Specifications Detail 18-32 voe. from panel Standby = 30 mA; Report Mode = 40 mA 4000 points maximum Note: Installation Instructions 574-836AC 579-954AC 579-954AC Description D1g1tal Alarm Communicating Transmitters with Serial Communications (SDACT) Information received 1s deterrn1ned by capability of the digital alarm communicating receiver (DACR) and com- munication format used. Up co 2. A 1 00-6052 SDACTs can be selected 32° F to 120° F (0° C to 49° C) 10-90% RH@ 85° F (30° C) Table 3: Telephone Requirements Detail SQWUSA-30334-AL-E Rj31 X (2 required) Loop start. pulse or tone dialing: Data Certified POTS lines AC2080-0009 Rev 7 7/2016 ~AUTO CALL Panel Mounted Digital A larm Communicating Transmitters with Serial Communications (SDACT) SDACT DACR Compatibility Reference Table 4: Compatibility Reference Available Communication Format ADEMCO 3/1 Standard 3/1 Standard 4/2 Standard 4/2 Standard I R d. . Radionics Contact a romcs 1800/2300 Hz 1900/1400 Hz 1800/2300 Hz 1900/1400 Hz BFSK I BFSK SIA ID (CID) (10 and 20 (10 and 20 I (10 and 20 1 (10 and 20 180012300 H 1900/1400 Hz Receiver/Service (Preferred) PPS) PPS) PPS) PPS) z Osborne/Hoffman Yes Yes Yes Yes Yes Yes Yes Yes Qu1ckAlert Model II ADEMCO 685, with Yes Yes Yes Yes Yes Yes Yes 685-8 Line Card Yes Yes Yes Yes Yes Yes Yes Silent Knight 9000 With 9004 line With 9004 line With 9004 line With 9004 line With 9004 hne With 9004 line With 9004 line card card card card card card card FBI CP220FB. with Yes Yes Yes Yes Yes Yes Yes Rec-11 Line Card Bosh Radionics Yes Yes Yes Yes Yes Yes D6500 Bosch Radionics Yes Yes Yes Yes Yes Yes Yes Yes D6600* SUR-GARD MLR2-DG Yes Yes Yes Yes Yes Yes Yes Yes DSC TL300** (UL & Yes ULC listed) Bosch C900V2** (UL y listed) es Yes Yes Yes Yes Yes Yes Yes * With or without D6680 Network Ethernet Adapter in D6600. ** DACT to Ethernet connection interfaces. Page 3 AC2080-0009 Rev 7 7/2016 ~AUTOCALL © 2018 Johrsor Cortrols. All rights reserved All spec1f1cat1oris and otrer 1nformat1or sr owr were current as of docurrert rev,s1orc ard are subject to charge w1th0Jt notice Add1t100al 11st1rgs rray be appltcable, contact your local Autocall product SJppl1er for the ,atest stat JS. Listings ard approvals Jnder Tyco =ire & SeCJnty Gmb~ and the proClJCt rames ltsted 1r this n,aterial are rrarks and/or registered rrarks unaJthonzed use 1s strict!\ proh1b1ted "=PA n and f\at1oral Fire Alarr,, Code are registered trademarks of the Nat1oral =1re Protecuor Assoc1auor (\J=PAJ. AC2080-0009 Rev 7 7/2016 .AUTO CALL UL, ULC Approved' System Accessories, LCD Annunciators A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fi re Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig 2: A4606-9205 LCD Annunciator with Platinum Trim Remote Color Touchscreen LCD annunciators for use with Autocall model 4007ES fire alarm control panels 4.3" (109 mm) diagonal color touchscreen display: · Provides the display features of the 4007ES fire alarm control panel at a remote location · Convenient and intuitive user interface provides detailed system status and individual point information · LED status indicators include Alarm, Priority 2, Supervisory, Trouble, Alarm Silenced, and Status of AC Power at the control panel · Supports dual language selection, including unicode character languages · Keyswitch is used to enable default access level; additional user access levels are passcode protected; keyswitch and user access levels are configurable · Tone-alert sounder provides local audible indication · Three programmable control switches with status LEDs and provisions for custom labeling Additional features: · Available with platinum or red trim · Information is transmined over a single unshielded twisted pair; separate wiring is required for 24 VDC power · Mounts flush on RACO 944, 5-gang electrical box (supplied separately) · Up to 6 Color Touchscreen LCD Annunciators per 4007ES fire alarm control panel Mounting box options (ordered separately): · Surface mount boxes in red or platinum · Semi-flush mount boxes in red or platinum, may be used for legacy annunciator retrofit applications * Add,uonal hsrings may be apphcaole; contact your local product supplier for the latest status Description Local Annunciation and Control A4606-9202 and A4606-9205 Series LCD Annunciators allows 4007ES fire alarm control panels to provide information and control switches at convenient locations away from the control panel. The color touch- screen LCD with backlighting displays information in clear and descript- ive language. (English is standard, other languages can be programmed.) Typical content includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, super- visory conditions, troubles, and custom location labels up to 40 charac- ters long. Communications Data communications require a single unshielded twisted pair that sup- ports other annunciators on the same communications channel. Indications Alarm, Priority 2, Supervisory, Trouble, and Alarm Silenced conditions are indicated by dedicated LEDs and a tone-alert audible indication. Each condition will cause the display to present a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Custom Background The 4007ES control panel supports a custom background image that is also displayed on each of the color touchscreen annunciators when status is normal. File types supported areJPG, BMP, GIF, and PNG. Recommended image type isJPG, recommended image size is 480 x 240, and the file size limit is 100 kb. Operation Keyswitch Access Touchscreen display access can be controlled by a keyswitch with a key that is removable only in the disabled position. Access is configurable per annunciator. Enabled Operations When the keyswitch is on, system status indications will be displayed as they occur with individual point detail as programmed at the control panel, and soft keys will be displayed to allow user aclions. Screen Backlight When the display has not been touched, and no new system status has occurred for 60 seconds, the backlight dims to 20% of normal bright- ness. If there is no activity in the system (System is Normal), the standby screen displays current time and date to verify proper operation. If an event occurs, or with the keyswitch activated, and the screen is touched, the backlight returns to full intensity Lamp Test The display menu provides a lamp test feature that when selected, activ- ates the 9 panel LEDs for 5 seconds. Dual-color LEDs will blink altern- ately. AC4606-0003 Rev. 2 1 /2017 -AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Product Selection lSKU Color A4606-9202 Red + A4606-9205 Platinum A2975-9461 Red A2975-9462 Platinum A2975-9463 Red A2975-9464 Platinum Table 1: Annunciator Product Selection Description Remote Color Touchscreen LCD Annunciator; for flush mounting in a 5-gang RACO 944 box, or equal, supplied separately Surface mount metal box for above annunciators Semi-flush mount metal box adapter for above annunciators; use for mounting on existing 2-gang, 4-gang, 6 gang, or 4" (102 mm) square flush mounted boxes Dimensions Annunciator: 13" W x 5.21" H x 2" D (330 mm x 132 mm x 51 mm) RACO 944 Box (reference): 12 ¼" W x 4½"Hx2½"D(311 mmx 114mmx 64mm) 12 ¼" W x 4 ½" H x 2 ½" D (311 mm x 114 mm x 64 mm) 12 ¼"Wx4 ½" H x 1 ¾" D(31 1 mm x 114 mm x 44 mm) Note: SKUs ending with BA are assembled in the USA fSKU __ A2081-9044 A2081-9028 Table 2: Suppression Products Description Overvoltage Protector, rated for up to 200 mA; use for RUI communications Isolated Loop Circuit Protector (ILCP), rated for 5 A maximum; use for 24 VDC power wiring when above 200 mA Additional Reference Data Sheet AC2081-0016 Data Sheet AC2081-0008 Note: Suppression is required where annunciator communications and power wiring exits and enters a building. Operator Information Page 2 Local Sounder Color Touchscreen LCD with sample Main Menu showing Alarm Indicator red LED 3 Programmable LEDs with Custom Label Insert and Optional Programmable Touchscreen Control Keys per LED; top two selectable as Red or Yellow. bottom selectable as Green or Yellow; for dual language, one of the control keys can be programmed to toggle between languages (insert is blank, labels shown are for reference) Control Enable Keyawltch controls all switch functions: key is removable only in disabled position AC4606-0003 Rev. 2 1 /2017 ~AUTO CALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Operator Screen Reference Fig 3: Main Menu Screen provides easy navigation to the function required. Buttons A, B, and C have programmable functions. OU■LE IN SYSTEM First Floor Hallway HEAT DETECTOR first o/ 2 CITY DISCONNECT TROUBLE POINT Ml-4-0 ABNORMAL Fig 5: System Trouble Screen identifies active troubles with custom labels displayed, arrows allow navigation through the list Page 3 First Floor, Main Lobby ZONELIST POINT Fig 4: System Alarm Screen identifies active alarms with custom labels displayed, arrows allow navigation through the list PRIMARY STAT\JS CURRENT DEVICE DEVICE PHYSICAL STATE RAW STATE AmVE STATE AHO STATE ENABLED STATE IIH\ICDTC"Tcn RUI NI.H3ER: LOCAL FIRE Al.ARM CORRECT DEVIO: ON-LINE ABNOPML ABNORNAL OFF Afff:O ENABLED Q Fig 6: Point Information Screen allows review of point details, arrows allow navigation through the information. AC4606-0003 Rev. 2 1 /2017 ~AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Specifications Specification Voltage Current Details Condition Alarm Display Active Standby Table 3: General Operating Specifications Ratl~ 18 to 32 c-cv=Dc--=.-s-ys-t-em_s_u_p"""'pl,,...ie-d,----- 4 Current Details 124 mA ~klight at full intensity and tone-alert sounding 70 mA 1 Backlight at full intensity, occurs when activity is in process Operating Temperature Range Operating Humidity Range 45 mA t Backlight dimmed to 20% of full intensity, occurs after 1 minute of no system activity 72° to 120° F (0° to 49° C) Up to 93% RH, non-condensing at 100° F (38° C) Table 4: Communications Specification Description ---- For 4007ES Panels Type RUI (Remote Unit Interface) external annunciator communications line SLC (signaling line circuit) Capacity ~ Up to 6 Color Touchscreen LCD Annunciators Specification RUI Data Power Wiring Earth Wiring Item ' Standard Wiring Type Wiring Characteristics Wiring Applications Requiring Shielded, Twisted Pair (STP) Class B "T-Tap" wiring distance Class X wiring distance Boxes for Flush Mounting (supplied separately) Page 4 Table 5: Wiring Requirements Description Unshielded twisted pair (UTP), 18 AWG (0.82 mm2) for most applications, see below 0.58 µF (580 nF) maximum capacitance between conductors; 35 0 maximum total line resistance Wiring that leaves the building. RUI wiring also requires A2081-9044 Overvoltage Protectors on each end. Wiring run in 500 ft (152 m) or more of conduit. Wiring closely bundled with standard ID Net communications or TrueAlert addressable communications (not required when run with IDNet+ communications). Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Up to 2500 ft (762 m) Terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm2) wires for 24 voe system power A dedicated earth ground connection to the electrical box is required for proper ESD and EMI protection; wire in accordance with NFPA 70 (National Electrical Code) Article 250 Table 6: Mounting Information Description 5-gang masonry box, RACO tt 944, 2 ½" (64 mm) deep or equal AC4606-0003 Rev. 2 1 /2017 -AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Reference Installation Instructions 4007ES Data Sheets Mounting Information Description 579-1172AC Table 7: Additional Reference AC4007-0001, 4007ES Hybrid AC4007-0002 Surface Mounting: Use Surface Mount Box 2-1/2" deep (64 mm) {ordered separately) Note: Flush Mounting: Use 5-gang RACO 944 box or equal, 2-1/2" deep (supplied separately) LCD Annunciator AHambly Trim Plate {supplied) Fig 7: LCD Annunciator Mounting Information · For surface mounting, use Autocall Surface Mount Box Model A2975-9461 (red) or A2975-9462 (platinum), 2-1 /2" deep (64 mm) (ordered separately). · For semi-flush mounting, use Autocall Semi-Flush Box Adapter Model A2975-9463 {red) or A2975-9464 (platinum), 1-3/4" deep (44 mm) {ordered separately); use for mounting on existing 2-gang, 4-gang, 6-gang, or 4" square flush mounted electrical boxes (supplied separately). Wiring Reference • I I r To othe, RUldeOoes --4007ES Fire Alarm Control Panel Wiring Reference on page 5 shows A4606-9202 LCD Annunciators. Note: Interconnection Wiring · Communication requires 18 to 12 AWG unshielded twisted pair. LCD Annunciators · Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus earth ground to each electrical box. · Refer to Install Instructions 579-1172AC for additional wiring specifications. Page 5 AC4606-0003 Rev. 2 1 /2017 ~AUTOCALL 0 2017 Johnson Controls. All rights reserved. All specifications and other information shown were currert as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire & Security GmbH, and the product names listed 1n tnis material are marks and/or registered marks. Unauthorized use 1s strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (N FPA). AC4606-0003 Rev. 2 1 /2017 .AUTO CALL UL, ULC Approved· TrueAlarm Analog Sensing TrueAlarm Analog Sensors -Phot oelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: · Digital rransmIssIon of analog sensor values via IDNet two-wire communications For use with the following Autocall products: , 4007ES, 4010ES, 4100ES, and 4100U Series control panels Fire alarm control panel provides: · Peak value logging allowing accurate analysis of each sensor for 1nd1v1dual sensitivity selection · Sensitivity monitoring satisfying NFPA 72 sens1tiv1ty resting requirements; automatic ind1v1dual sensor calibration check verifies sensor integrity · Automatic environmental compensation. mulri-stage alarm operation, and display of sensIt1vIty directly In percent per fom · Ability to display and print detailed sensor 1nforrnat1on In plain English language Photoelectric smoke sensors provide: · Seven levels of sensItIvIty from 0.2% to 3. 7% Heat sensors provide: · Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F · Rate-of-rise remperarure sensing · Utility temperature sensing · Listed to UL 521 and ULC-S530 General features: · Operation Is for ceiling or wall mounung · Listed to UL 268 and ULC-S529 · Louvered smoke sensor design enhances smoke capture by d1rernng flow to chamber· entrance areas are m1n1mally visible when ceiling mounted · Designed for EMI compat1bil1ty · MagnetlC test feature Is provided · Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm 1nd1cator Additional base reference: · For isolator bases, refer to data sheet AC4098-0025 · For sounder bases, refer to data sheet AC4098-0028 · For photo/heat sensors. refer to data sheer AC4098-0024 (single address) and AC4098-0033 (dual address) Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement d1g1tally com- mun1Cated to the host control panel using Autocall addressable com· murncauons. At the control panel. the data Is analyzed and an average value Is determined and stored An alarm or other abnormal cond1t1on Is determined by comparing the sensor's present value against its average value and nme. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point This software filtering process compensates for environ mental factors (dust, dirt, etc.) and component aging. providing an accur· ate reference for evaluating new awvIry With this filtering. there Is a sIg nificant reducuon in the probability of false or nuisance alarms caused by shifts In sensIt1V1ty. either up or down. Control Panel Selection. Peak actlVlty per sensor Is stored to assist in evaluating specific loca- tions. The alarm set point for each TrueAlarm sensor Is determined at the host control panel, selectable as more or less sensIt1ve as the 1nd1- v1dual application requires. ---------------,- Fig 1: A4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for urned automatic sensIt- 1vity selection (such as more sensIt1ve at night, less sensIt1ve during day). Control panel programming can also provide multi-stage operation per sensor For example, a 0.2% level may cause a warning to prompt invest IgarIon while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications w1rh rhe panel. If the control panel determines a sensor Is in alarm, or is dirty or has some other type of trouble, the details are annunoated at the con- trol panel and that sensor base's LED will be turned on steadily. During a system alarm. the control panel will control the LEDs such that an LED 1ndicat1ng a trouble will return to pulsing to help 1denufy the alarmed sensors. Sensor Base Features Base mounted address selection: · Address remains with its programmed location · Accessible from front (DIP switch under sensor) General features: · Automauc 1dent1ficat1on provides default sens1t1vIty when substituting sensor types · Integral red LED for power-on (pulsing), or alarm or trouble (steady on) · Locking anti-tamper design mounts on standard outlet box · Magnencally operated functional test Sensor Bases A4098-9792, Standard Sensor Base A4098-9789, Sensor Base with wired connections for: · A2098-9808 Remote LED alarm 1nd1cator or A4098-9822 relay (relay Is unsupervised and requires separate 24 VDC) Supervised Relay Bases : · A4098-9791, 4-Wire Sensor Base, use with remote or locally mounted A2098-9737 relay, requires separate 24 voe , A4098-9780, 2-Wire Sensor Base, use with remote or locally mounted A4098-9860 relay, no separate power required · Supervised relay operanon Is programmable and can be manually operated from control panel · Includes wired connecnons for remote LED alarm 1nd1cator or A4098-9822 relay (relay Is unsupervised and requires separate 24 VDC) AC4098-00I9 Rev. 22 11 /2016 -AUTOCALL TrueAlarm Analog Sensors -Photoelectric and Heat; Standard Bases and Accessories Sensor Base Options A2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A@ 28 VDC; non-power limited rating of 3 A@ 120 VAC (requires external 24 voe coil power) A4098-9860, Remote or local mount supervised relay: · SPOT dry contacts. power limited rating of 2 A@ 30 VDC. resistive; non-power limited rating of 0.5 A@ 125 VAC. resistive A4098-9822, LED Annunciation Relay: Arnvates when base LED Is on steady, indicating local alarm or trouble · DPDT contacts for resistive/suppressed loads, power limited rating of 2 A@ 28 VDC; non-power limited rating of 1 /2 A@ 120 VAC. (requires external 24 voe coil power) 4098-9832, Adapter plate: · Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box · Can be used for cosmetic retrofitting to exIstIng 6-3/8" diameter base product A2098-9808, Remote red led Alarm Indicator: · Mounts on single gang box (shown in illustration) Description (S) AURM 0 (S) Fig 2: Remote red LED Alarm Indicator TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output Is d1g1t1zed and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When condmons are temporarily dusty. instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will 1nd1cate an incorrect sensor type. the heat sensor will operate at a default sensIt1V1ty providing heat deternon for building protection at that location. Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: · Selectable rate compensated fixed temperature sensing with or without rate-of-rise operation · Rated spacing distance between sensors: FM Spacing, Either Fixed Temperature Setting Fixed Temp. Setting 135° F (57.2° C) UL & ULC Spacing 60 ft X 60 ft (18.3 m) ~ 20 ft x 20 ft (6.1 m) for fixed temperature only: RTI = Quick 155° F (68° C) 40 ft x 40 h (12.2 m) Note: *190° F (88° C) ratings apply only to the A4098-9734 sensor. Smoke Sensors: · Photoelectric technology sensing · 360° smoke entry for optimum response · Built-in insect screens Page 2 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selernon; RTI = Ultra Fast AC4098-0019 Rev 22 11 /2016 Mounting Reference Product Relay Supervised Relay Adapter plate TrueAlarm Bases Page 3 -AUTO CALL TrueAlarm Analog Sensors -Photoelectric and Heat; Standard Bases and Accessories Electrical Box Requirements: (boxes are by others) Without relay In the box: 4" octagonal or4" square, 1-1/2" deep; single gang, 2" deep With relay 111 the box : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box Surface mount reference........_ 4" (102 mm) Octagonal Box ~I I I I I I' T 1-1/2" (38 mm) I Flush mount reference, mount even with final minimum box depth surface, or with up to 1 /4" (6.4 mm) maximum recess Supervised Relay1· Relay (mounts (mounts in base electrical box or in base electrical box) remotely) ._ ___ i_.,, ~ Relay Size: 2-1 /2" X 1-1/~" r I (3.75 in3 ) (64 mm X 38 mm X 25.4 mm) Supervised Rela/(mounts in base J electrical box or remolely; 2-3/8" X 1-1 /4" X 11/32" (1 in3 ) (60.4 mm X 31.8 mm X 8.6 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 1+------6-3/8" (162 mm) -----.___ t 1/4" (6.4 mm) Adapter Plate, required for mounting to surface mounted boxes and 4" square flush bois i---4-7/8" (124 mm) ---.i 15/16" IT ) ~4mm) ~ □ '------------~ TrueAlarm Bases Fig 3: Mounting Reference Table 1: Product mounting -SKU reference SKU A4098-9822 1 A20989739 2. A4098-9860 4098-9832 A4098-9780. A4098-9789, A4098-9791 A4098-9792 AC4098-0019 Rev. 22 11 /2016 -AUTO CALL TrueAlarm Analog Sensors -Photoelectric and Heat; Standard Bases and Accessories A4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photod1ode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensItIvIty are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sens1t1v1t1es of 0.2%, 0.5%, and 1 % are for special applicanons in clean areas. Standard sens1tiv1t1es are 1.5%, 2.0%, 2 5%, 3.0%. and 3.7%. Application type and sens1t1vity are selected and then monitored at the fire alarm control panel * The sensor head design provides 360° smoke entry for opnmum response to smoke from any d1rernon. Due to its photoelectric operation, air velorny Is not normally a factor, except for impact on area smoke flow. T -7/8" (124 mm , __ r _LEO status indicator 2-1 /8" ''f Fig 4: A4098-9714 Photoelectric Sensor with Base A4098-9733 and A4098-9734 Heat Sensors TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to ,rs small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel Rate-of-rise temperature deternon Is selectable at the control panel for either 15° F (8.3° CJ or 20° F (11.1 ° C) per minute. Fixed temperature sensing Is independent of rare-of-1 ,se sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire. the temperature may nor increase rapidly enough to operate the rate-of-rise feature However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm hear sensors can be programmed as a utility device to monitor for temperature extremes In the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems Refer co specific panels for availability. T i+-------4-7/8" (124 mm n.._ LEO status indicator 2-3/8" "T Fig 5: A4098-9733 Heat Sensor with Base 2-3/8" (60mm) Fig 6: A4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locanons should be determined only after careful cons1derauon of the physical layout and contents of the area to be protected Refer to NFPA 72. the National Fire Alarm and Signaling Code On smooth ceilings. smoke sensor spacing of 30 ft (91 m) may be used as a guide • * For detailed application information 1nclud1ng sens1t1vIty selernon. refer to Installation lnstrurnons 574-709AC Page 4 AC4098-0019 Rev. 22 11 /2016 ~AUTO CALL TrueAlarm Analog Sensors -Photoelectric and Heat; Standard Ba ses and Accessories TrueAlarm Analog Sensing Product Selection Chart SK\.J Color A4098-9792 White A4098-9776 Black A4098-9789 White A4098-9789 White A4098-9775 Black A4098-9791 ** White A4098-9780** White Table 2: TrueAlarm Sensor Bases (for use with Sensors A4098-9714 and A4098-9733) ------r Description l Standard Sensor Base Compatibility No options Sensor Base with connecuons for Remote LED Alarm Indicator A2098-9808 Remote Alarm Indicator or A4098-9822 Unsupervised Relay or Unsupervised Relay 4-Wlre 5e115or Supervised Relay A2098-9737 Supervised Remme Relay Base with connernons for LED A2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay A4098-9822 Unsupervised Relay 2-Wire Sensor Supervised Relay A4098-9860 Supervised Remote Relay Base with connections for LED A2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay A4098-9822 Unsupervised Relay Mounting Requirements 4" octagonal or 4" square box, 1-1/2" min. depth; or single gang box, 2" min. depth 4" octagonal or 4" square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** A4098-9791 and A4098-9780 are NOT compatible With the 2120 CDT Refer to Appl1cat1on Manual 574-709AC and lnstallanon lnstrucnons 574-707AC for addinonal 1nformat1on. SKU A4098-9714 A4098-9714 IND A4098-9774 A4098-9733 A4098-9778 A4098-9734 SKU A2098-9737 A4098 9860 A2098-9808 A4098-9822 4098-9832 Specifications Specification Color White Description Table 3: TrueAlarm Sensors compatibility Photoelectric Smoke Sensor Bases A4098-9775, A4098-9776, Mounting Requirements Black White A4098-9792, A4098-9789, A4098-9791, Refer to base requirements Black Heat Sensor and A4098-9780 White High Temperature Heat Sensor Table 4: TrueAlarm Sensor/Base Accessories Description Supervised Relay, mounts remote or in base electrical box Supervised Relay, mounts remote or in base electrical box Compatibility For use win A4098-9791 base For use wIt1 A4098-9780 base Mounting Requirements Remote Mounting requires 4" octagonal or 4" square box. 1-1 /2" minimum depth Base Mounting requires 4" octagonal box. 2-1/8" deep with 1-1/2" extension ring Remote Red LED Alarm Indicator on single gang stainless steel plate Bases A4098 9789. A4098-9791, and A4098_978J Single gang box, 1-1 /2" minimum depth Unsupervised Relay, tracks base led status; Note Mounts only In base electrical box Adapter Plate Bases A4098-9789, A4098-9791. and 4" octagonal box, 2-1 /8'' deep with 1-1 /2" A4098-978'.l extension ring Bases A4098-9792. A4098-9789, A4098-9791, and A4098-9780 Required for surface or sem1-nush mounted 4" square box and for surface mounted 4•· octagonal box Table 5: General Operating Specifications Rating Communications and Sensor Supervisory Power Communicauons Connernons IDNet communications, aura-selected. 1 address per base Screw terminals for in/out wiring. 18 to 14 AWG (0.82 mm2 to 2 08 mn/) 1 mA typical. no impact to alarm current Remote LED Alarm lnd1caror Current Remote LED Alarm Indicator and Relay Connernons Color coded wire leads, 18 AWG (0.82 mm2 ) Page 5 AC4098-0019 Rev 22 11/2016 Specification UL Listed Operating Temperature Range With A4098 9733 Heat Sensor Table 5: General Operating Specifications Rating 32° to 100° F (0° to 38° C) 32° to 122° F (0° to so· CJ Operating Temperature Range with A4098-9714 Smoke Sensor 1 s0 to 122° F (-9° to so· ci With A4098-9734 Heat 32° to 1 so° F (0° to 66° CJ Sensor Storage Temperature Range Humidity Range 0° F to 140° F (-18° C to 60° C) 10 to 95% RH A4098-9714 Smoke Sensor Air Velorny Rating Housing Color 0-4000 ft/min (0-1220 m/m1n) Frost White or Black Specification Externally Supplied Relay Coil Voltage Supervisory Current Alarm Current with A2098-9737 Relay Specification Power Table 6: A4098-9791 Base With Supervised Remote Relay A2098-9737 Rating 18-32 VOC (nominal 24 VOC) 270 µA, from 24 voe supply 28 mA, from 24 voe supply Table 7: A4098-9780 Base With Supervised Remote Relay A4098-9860 Rating Supplied from communications -AUTO CALL Table 8: A4098-9822 Unsupervised Relay, Requirements for Bases A4098-9789, A4098-9791 , and A4098-9780 Specification Externally Supplied Relay Coil Voltage Supervisory Current Alarm Current Rating 18-32 voe (nominal 24 VOC) Supplied from communIcatIons 13 mA from separate 24 voe supply © 2017 Jorrsor Cortrols. All ngrts reserved All spec1f1cat1ors and other 1nforrrat1or srowr were CJrrent o> of document rev1s1on and are SJbJeCt to crarge w1trOJt notice. Add1t1ora1 l1st1rgs rray be applicable. contact yo.ir local AJtocall product sJpp11er for ere latest stat0s. Listings ard approvals Jnder Tyco Fire & Security Gmb-and the prod~ct rames listed 1r ttliS material are rrarks ardror rei;1stered rrarks unauthorized .se 1s strictly prohibited. t\•PA 72 and Nat1ora1 Fire Alarm Code are registered trademarks of tre t\at1onal •ire Protecuor ASsoc1at1or (\FPA1 AC4098-0019 Rev. 22 11 /2016 .AUTOCALL UL. ULC Approved· Multi-Application Peripherals IDNet Communicating Devices Addressable Manual Stations Features Individually addressable manual fire alarm stations with: • Power and data supplied via IDNet addressable communications using a single wire pair · Operation that complies with ADA requirements · Visible LED indicator that flashes during communications and Is on steady when the station has been activated · The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pl:JII lever for applicanons where ant1c1pated users may find the standard station lever difficult to arnvate · Pull lever that protrudes when alarmed · Break-rod supplied (use 1s optional) · Models are available with single or double action (breakglass or push) operation · UL listed to Standard 38 Compatible with the following Autocall control panels: · Model Series 4007ES. 401 0ES. 41 00ES fire alarm control panels equipped with IDNet communications Compact construction: · Electronics module enclosure mInimIzes dust 1nfiltrat1on · Allows mounting In standard electrical boxes · Screw terminals for wIrIng connections Tamper resistant reset key lock (keyed same as Autocall fire alarm cabinets} Multiple mounting options: · Surface or semi-flush with standard boxes or matching Autocall boxes · Flush mount adapter kit · Adapters are available for retrofitting to commonly available existing boxes Description The Autocall addressable manual station combines the familiar Autocall manual station housing with a compact communicallon module that Is easily installed to satisfy demanding applications. Its integral ind1v1dual addressable module (1AM) constantly monitors status and communicates changes to the connected control panel via IDNet communica\lons wiring. Operation Activation of the A4099-9004 single acnon manual station requires a firm downward pull lO arnvate the alarm switch. Completing the arnon breaks an internal plastic break-rod (v1s1ble below the pull lever use Is optional). The use of a break-rod can be a deterrent to vandalism without 1nterfer1ng with the minimum pull requirements needed for eas~ arnvallon. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station A4099-9021. For applications such as California Building Code, Title 24. which requires ··controls and operaung mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twIst1ng of the wrist'· the model A4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of ex1snng stations Is available using the A4099 9805 Retrofit kit Double Action Stations (Breakglass} require the operator to srnke the front mounted hammer to break the glass and expose 1he JI t.-1 I JI I ,.j p rl J I lJ ·j,l1, I f I !I • j l• I ,!, 1 ! recessed pull lever The pull lever then operates as a single acnon stallon. A4099-9004 Single action A4099-9005 Breakglass I _J., A4099-9021 NO GRIP A4099-9805 NO GRIP Single acnon A4099-9006 Push Retrofit kit With A2099-9828 lnsmutional Cover kit Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action stallon Station reset requires the use of a key to reset the manual stanon lever and deactivate the alarm switch. (If the break-rod Is used, it must be replaced.) Station testing Is performed by physical act1vat1on of the pull lever. Electrical testing can be also performed by unlocking the station housing to arnvate the alarm switch. AC4099·0005 Rev. 1 8/2016 -AUTO CALL IDNet Communicating Devices Addressable Manual Stations Specifications Refer to Installation Instructions 579-1135AC for additional 1nformat1on. Specification Power and Communications Address Means Wire Connections UL Listed Temperature Range Humidity Range Housing Color Material Pull Lever Color Housing Dimensions Table 1: Specifications Rating I0Net communications, 1 address per station DIP switch, 8 position Screw terminal for in/out wiring, for 18 to 14 awg wire (0 82 mm2 to 2.08 mm2) 32° ro 120° F (0° to 49° C) intended for indoor opera11on Up to 93% RH at 100° F (38° F) Red with white raised lettering Housing and pull lever are Lexan polycarbonate or equal White with red raised lettering 5" H x 3 3/4" W x 1" D (127 mm x 95 mm x 25 mm) Addressable Manual Station Semi-Flush Mounting 4" Square Box Mount --......._ 4" (102 mm) square box, 2 1/6" (54 mm) minimum '-~-------~ depth, RACO #231 or equal (supplied by others) Single Gang Box Mount ~ Single gang bex, 2 1/2" deep : ' (64 mm), RACO #500 er equal ' 1 (supplied by ethers) PULL DOWN i LED lndicater 0 Single gang cever plate, 3/4" (19 mm) extensien, RACO #773 er equal (supplied by ethers) Mount flush or with 1/16" (2 mm) maximum extension DO NOT RECESS Statien side view 4" Square box { with cover plate -----------. I I I I I I I I I I I I I I I I I I I I ·---------- Single gang box outline Wall surface /L--_______ .J Semi-Flush Mount Side View Fig 1: Addressable Manual Station Semi-Flush Mounting Page 2 AC4099-0005 Rev 1 8/2016 -AUTO CALL IDNet Communicating Devices Addressable Manual Stations Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown In the 1llustrat1on to the right. Additional Mounting Reference, Refer to Addressable Manual Station, Additional Mounting Information on page 5 for W1remold box mounting compaubll1ty The 1llustrat1on shows the 2975-9178 box and the 2975-9022 cast box. Page 3 Box 5-3/16" H X 4" W x 2-3/16" D (132 mm x 102 mm x 56 mm) (ordered separately) Knockouts located top and bottom 0 PULL DOWN Cast Box 5" H x 3-7/8" W x 2-3/16" D (127 mm x 98 mm x 56 mm) (ordered separately) 0 0 0 Ls=~ ! Access for 3/4" threaded . 5" conduit located top and bottom (127 mm) - l '------------' ~5.4 mm) f.-3-3/4" (95 mm)-..j )-- Fig 2: A4099 Series Addressable Manual Station AC4099-0DDS Rev. 1 8/2016 -AUTO CALL IDNet Communicating Devices Addressable Manual Stations Surface Mount Side View with Internal Detail The 1llusrrat1on shows the 2975-9178 box. Field wiring (shown for reference) Address setting under resealable label (accessible with cover open) Application Reference Station cover hinges open for installation access 1-1 /4" (32 mm) Box (shown for reference) 2-5/8" (67 mm) Switch wiring (prewired) Refer to NFPA 72, the Notional Fire Alarm and Signaling Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. 1 Stations shall be located In the normal path of exit and distributed In the protected area such that they are unobstructed and readily accessible. 2 Mounting shall be with the operable part not less than 42 In (1.07 m) and nm more than 48 in (1.22 m) above fioor level 3 At least one station shall be provided on each fioor. Additional stations shall be provided to obta1r> a travel distance not more than 200 ft (61 m) to the nearest starion from any po,nt ,n the building. 4 When manual station coverage appears limited In any way, addmonal stations should be installed Page 4 AC4099-0005 Rev. 1 8/2016 ~AUTOCALL IDNet Communicating Devices Addressable Manual Stations Addressable Manual Station, Additional Mounting Information For retrofit and new 1nstallat1ons, additional compatible mounting boxes and the required adapter plates are shown In the 1llustrat1on The 1llustrat1on shows the 2099-9814 surface mm for W1remold boxes and the 2099-9813 sem1-nush mm for 2 gang switch boxes. Addressable station ~ trim for Wiremold box 5-1/8" H x 5" W (130 mm x 127 mm) Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W (152 mm x 114 mm) c:) c:) Addressable Manual Station, Flush Mounting Information s· (203 mm) Front View Flush mount adapter kt Black The flush mount adapter kit Is available In beige (2099-9820) or black (2099-9819) Page 5 c:) Wiremold receptacle box model V5744-2 (supplied by others) Two gang switch box, each 3" H X 2" W X 2-3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) ) ~ Side View AC4099-0005 Rev. 1 812016 -AUTOCALL Addressable Manual Station Product Selection Table 2: Addressable Manual Station Product Selection Red Housing with White Letters and White Pull Lever SKU A4099-9004 A4099-9004CB A4099-9004CF A4099-9004PO A4099-9004SP A4099-9005 A4099-9005PO A4099-9005SP A4099-9006 A4099-9006PO A4099-9006SP A4099-9021 SKU '2975-9022 2975-9178 2099-9813 2099-9819 2099-9820 A4099-9805 2099-9803 2099-9804 A2099-9828 2099-9814 2099-9822 1 Description Housing Single Acrion, English FIRE ALARM Single Action, Bilingual English and French FEU FIRE Single Action, French ALARME FEU Single Action, Portuguese FOGO ALARME Single Action, Spanish ALARMA FUEGO Double Action, Breakglass operation, English FIRE ALARM Double Action, Breakglass operation, Portuguese FOGO ALARME Double Action, Breakglass operation, Spanish ALARMA FUEGO Double Action, Push operation, English FIRE ALARM Double Action, Push operation, Portuguese FOGO ALARME Double Action, Push operation, Spanish ALARMA FUEGO Single Action NO GRIP operation, English FIRE ALARM Table 3: Accessories Description Cast aluminum surface mount box, red Surface mount steel box, red Sem1-fiush mm plate for double gang switch box. red Flush mount adapter kit. black Flush mount adapter kit. beige Pull Lever Listings PULL DOWN UL ULC TIREZ PULL ULC ABAISSEZ PUXE JALE UL PULL DOWN UL, ULC PUXE JALE UL PUSH PULL DOWN UL ULC EMPURRE PUXE UL EMPUJE JALE PULL DOWN UL ULC Retrofit Kit for field conversion of a single acnon station to a NO GRIP station; refer to Installation Instructions 579-1007AC for details Replacement breakglass Replacement break-rod lnsrnutional cover kit for field 1nstallat1on on A4099-9004. Note: Covers LED 1nd1cator Surface tnm plate for W1remold box V5744-2, red Replacement retaining cl,p for breakglass It 2017 Johnsor Cortrols All right: reserved All spec1f1cauons ard other 1nformat1or srown were currem as of document rev,s,on ard are SJbJect to charge w,thOJt notice Add1t1o~al listings n·a) be apphcable. cortact yoJr local AJwcall product sJppl,er for the latest statJS Listings ard approvals Jnder Tyco crre & Security Gmb-, and tre prodJCt rarnes hsted ir tr,s material are marks and/or registered marks UnaJthorized Jse 1s strictly prohibited \f'.PA 72 ard '1.at,oral ,,re Alarll' Code are reb1stered trademarks of the ·,auonal c,re Protect1or Assoc1at1or (N;:PA) AC4099-0005 Rev 1 8/2016 .AUTOCALL UL, ULC Approved· Multi-Application Peripherals IDNet Com m u nicating Devices, Individual Addressable Modules (IAMs) Features IDNet addressable communications supply both data and power over a single wire pair to provide** · Supervised Class B monitoring of normally open, dry contacts · Total wiring distance from 1AM to supervIsIon resistor(s) of up to 500 ft (152 ml · Monitored connection Is compatible with AutocallA2081 -9044 Overvoltage Protectors for outdoor wiring or elecmcally noisy applications · For use In indoor locauons up to 158° F (70° C) such as attic spaces or similar applicauons For use with following Autocall control panels Model Series 4007ES, 4010ES, and 4100ES fire alarm control panels for IDNet communications Model A4090-9001 · Enclosed design mInimIzes dust infiltration · Mounts In standard single gang electrical box · Screw terminals for wiring connections · Visible LCD flashes to indicate communications · Optional covers are available to allow LED to be viewed after 1nstallat1on (requires mounung bracket, ordered separately) Model A4090-9051 · Encapsulated design for extended exposure to high hum1d1ty (LED Is not present on this model) · Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring · Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same cIrcuIt using one point · Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel · Contact closure status can be tracked · Momentary contact closure conditions can be selected at the panel to be latched or tracked, UL listed to Standard 864 UL listed to Standard 864 Description Individual addressable modules (IAMs) receive both power and communications from a two-wire IDNet circuit. They provide location specific addressability to a single InnIatIng device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring nor- mally open dry contacts and the wiring to an end-of-line resistor SKU A4090-9001 A4090-9001 Is packaged in a thermoplastic housing and provides screw terminal connections and a status 1nd1cat1ng LED. SKU A4090-9051 A4090-9051 Is an encapsulated package with wire leads. It does not provide a status indicating LED Operation Contact Closure Fig 1: A4090-9001 Supervised 1AM Fig 2: A4090-9051 Supervised 1AM Closure of the monitored contact(s) Inl[lates an alarm or other response as programmed at the fire alarm control panel An open In the mon 1rored cIrcuIt wiring will cause a trouble to be reported Panel Selections Selecnons can be made at the control panel to maintain the alarm con- dition 1f the Init1anng devtCe contacts are momentary, such as from a rate of rise heat derec10r, or to track the dev,ce contact status Current Limited Operation Applications For use with IDNet communications only these IAMs can provide quad- state sensing of normal, open circuit. short circuit, and current limited conditions. (Program type Is "T-sense ") With the proper end of-line and current llm1t1ng resistors, dual funrnons such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. AC4090-0001 Rev 12 812016 1AM Product Selection SKU A4090-9001 A4090-9051 'SKU A4090-9806 A4090-9807 A4090-9810 ISKU A4081-9004 A4081·9003 A4081-9005 Specifications Specification Power and Commun1cat1ons Input Requirements Wire Connections Reference Documents Specification Distance from 1AM to Contacts -AUTOCALL IDNet Communicating Devices, Individual Addressable Modules (IAMs) Table 1: 1AM Product Selection Description Supervised 1AM, mounted In thermoplastic housing with screw terminals; see applicable options below Supervised 1AM, encapsulated with wire leads Table 2: Optional Trim Plates and Mounting Bracket for Model A4090-9001 Description For semi-flush mounted box Trim plate with LED viewing window, requires A4090-9810 mounting bracket. includes mounting screws; galvanized steel For surface mounted box Mounting bracket. mounts 1AM to electrical box and provides screw holes for trim plate, required for optional trtm plates Table 3: End-of-Line Resistor Harnesses (ordered separately as required) 1 Reference no, 733-886 733-896 733-984 A4090-9001 A4090-9051 Installation Instructions Field W1nng Diagrams Description 6.8 kO, 1 /2 W; Standard end-of-line resistor harness for N.O. contact supervIsIon 4.7 kO, 1/2 W Use for current limited monitoring 1.8 kO, 1 /2 w applications Table 4: Electrical Rating IDNer, auto selected, 1 address per 1AM Normally open. dry contacts Screw terminals for in/our wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) 574-331AC for A4090-9001, 579-572AC for A4090-9051 842-073 for IDNe1 operation Table 5: Wiring Distances Rating 500 ft (152 m) maximum without protectors Wiring Distance Reference per channel. IDNet Communications 400 ft (122 m) maximum with A2081-9044 Overvoltage Protectors 2500 ft (762 rn) maximum from fire alarm control panel 10,000 ft (3048 m) maximum total wiring distance (1nclud1ng T-Taps) Specification D1mens1ons Housing Material, A4090-9001 Encapsulatton Material, A4090-9051 Temperature Range Page 2 A4090-9001 A4090-9051 Table 6: Mechanical Rating 1-9/16'' W x 1-3/4" H x 1-1 /4" D (40 mm x 44 mm x 32 mm) 1-9/16'' W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Black thermoplastic Epoxy, beige 32° to 158° F (0° to 70° C), intended for indoor operation AC4090-0001 Rev. 12 8/2016 -AUTO CALL IDNet Com m unicating Devices, Individual Addressable Modules (IAMs) Specification Hum1d1ry Range Mounting Information IDNot suporvisod 1AM Table 6: Mechanical Rating Up rn 93% RH at 100° F (38° C) Fiold wiring shown for roforonco Singlo gang oloctrical box 2-112" (64mm) minimum doplh ( suppliod by othors) Addross sotting undor rosoalablo labol Single gang blank cover plate and mounting screws, for uso when LED is not roquirod to bo oxtomally viowod (suppliod by others) Fig 3: Mounting Reference, Single Gang Blank Cover Plate Note: Figure 3 shows A4090-9001 IDNer supervised 1AM 4-114" (108 mm) @ @ Light pipe for ✓ LED viewing ~ @ 2-112" (64 mm) Trim plate fer semi-ffush meunted bex r -~ J-,,. =· •:c l .. "· .. l EE'~-, 'E' 'I @ 1-2-13/16" ~(72mm) __ .._ Trim plate fer surface meunted bex ~ ~ 4-112" □ (114mm) ' Meunting bracket, erdered separately Fig 4: Optional Trim Plates and M ounting Bracket for Visible LED Note: Figure 4 shows the following: · A4090 9806. Trim plate for semi-flush mounted box · A4090 9807, Trim plate for surface mounted box · A4090-9810, Mounnng bracket. ordered separately Page 3 AC4090-0001 Rev. 12 8/2016 A4090-9051 Mounting Information Addross sotting is at roar of housing 0 Singlo gang oloctrical box 2-1/2" (64mm) minimum dopth (suppliod by othors) Single gang blank covor plato and mounting scrows (suppliod by othors) Fig 5: A4090-9051 Mounting Information Note: Figure 5 shows a A4090-9051 Encapsulated Supervised 1AM. -AUTO CALL :!017 Jorrson Cortrols All rigi"rs reserved All spec1f1cat1ons and other 1rforrrat1or s~•own were urrent as of dOCJmert rev1s1or ard are sctbJect to crarge w1thOJl rot1ce Addmonal listings rray be applicable. contact yoJr local AJtocall product supplier fo1 tre latest status. List1rgs and approvals Jnder Tyco l'1re & SecJnty Grrb-, and ti"e product rames listed 1r this rraterial are marks ardior registered rrarks Urauti"orized ose 1s smct11 pror1b1ted l\=PA 72 and l\at1oral i:1re Alarrr Code are registered tradenrorks of tre l\anoral •ire Prorecuor Assoc1at1or ('J;:PA) AC4090-0001 Rev. 12 8/2016 .AUTOCALL UL. ULC, CSFM Listed' Addressable Detection Products Auto-Aligning Reflective Beam Smoke Detectors with IDNet Communications Features Auto-aligning reflective beam smoke detector system with on- board IDNet addressable communications: · Compatible with Autocall 4007ES, 401 0ES, and 41 00ES fire alarm control panels. · Autocall addressable beam smoke detectors add IDNet communicanons to the proven FireRay 5000 Series beam smoke detection system. · Communicates status 1nformat1on, and receives commands and sensItIvIty threshold selernon from the host fire alarm control panel. Photoelectric transmitter and receiver are combined in a single, compact housing: · Connect up to two remote detector heads to one ground level controller. · An on-board microprocessor analyzes light reflected from an infrared beam reflecting from a matching prism. · Operating range covers 26 ft, 3 In. to 330 ft (8 m to 100 m). · Modular design with easy[ir mounting system and LASER assisted prism mounting provides convenient mounting and adJustment. · Auto-Align beam alignment operation conveniently rotates beam to align to the prism center during 1nstallanon. · AutoOpt1m1se operation automatically maintains alignment for reliable operation · UL 268 and ULC-SS29 listed. On-board microprocessor controlled operation includes: · Ground level system controller with LCD. · Operating voltage range 14 VCD to 36 VDC. · Easy serup and alignment with built in electronic UL/ULC obscuranon acceptance test selectable from host control panel. · Automatic gain control, contamination compensation, building shift compensation with control and monitoring of alignment motors. and ability to change Delay to Fire and Delay to Fault timings Host fire alarm control panel operations include: · Sens1t1v1ty selernon from 10% to 60% (35% default) · Point type selernon (Fire. Latched. Supervisory, or Utility) and set Almost Dirty threshold · Initiate obscurat1on test. reset latched cond1t1ons. Enable/Disable, and control beam head LED Host fire alarm control panel information received includes: · Smoke status. Controller-to-Detector Communications status. Rapid Obscuration status (beam blocked). Self-alignment status, Almost Dirty status, Excessively Dirty status. and general summaryTrouble status · Analog values for signal strength and compensanon level, see D, J rIprI· •r for more information. Figure 1: Addressable beam detector head Figure 2: Addressable beam control station Applications: · Large open areas such as warehouses. hotel atriums. industrial plants, and school gymnasiums. · Public areas where cosmetics are of prime importance and detector heads need to be small and unobtrusive. such as shopping malls. libraries, theaters. and churches Optional accessories: · Detector· adJustmenr bracket. back box, and cover plate · Controller back box. · Extended prism mounting options. 'fl,1111-i111 I ..,r r,iir rll1v1t., 111-iir! ')tr1l1 111f' .. ~l',lr1l(('>''./Ji11 ,,r,rt ~11r,1~1.1.1111! t ,lit rr1 1ltl II j d1•l'f ( 1t •II 1•1 J.1 t .1JI( ii 1, ,r,1\11 I !lll15'f'Jl•1r1,l1,rr f·r,11rj1r,tlt ,-J J/H--'11 AJJ111 rc1J l,.u,g n vtP ,r,1, ill• ,r Id r V I! I ,-1l A H AC4098-0049 Rev 5 1/2020 Description Convenient installation and alignment -AUTOCALL Auto-Aligning Reflective Beam Smoke Detectors with IDNet Communications Autocall addressable beam smoke detection provides the proven F1reRay 5000 system features of auto-aligning infrared beam smoke detection combined with IDNet addressable communications When the detector head Is installed using the easy/it mounting system, an integral laser can be arnvated that alignes along the optical path of the infrared beam. Locating the reflective pnsm Is quick and accurate using the Auto-Align beam alignment feature. AutoOptimise Beam Alignment The AutoOpt1m1se beam alignment system automatically steers and maintains the beam in the optimum position for reliable performance. The transmitter element generates the signal, the prism reflects it back to the receiver element, and then It Is analyzed for the presence of smoke. The beam control stanon determines an alarm condition when it reaches the predetermined level. Alarm threshold levels are set using the host fire alarm control panel. Time to Fire and Time to Fault are set using the beam control station. Mounting reference The maximum distance of the detector and the reflector from the ceiling must be 10% of the distance between the floor and ceiling. Lateral deternon may be up to 30 ft (9144 m) on either side of the beam, prov1d1ng a maximum total coverage area of up to 19,800 square feet (60 ft x 330 ft or 18.29 mx 100 m) Refer to the installation InstructIons supplied with the product. and ro NFPA 72, the Nauonal Fire and Signaling Code for additional 1nstallat1on guidance Communications to the host control panel To InvestIgate the beam heads remotely, the host fire alarm control panel receives status and numerical informat1on from the beam controller The beam controller receives commands, and the Smoke and Almost Dirty threshold levels are set using the host control panel. Numerical information received includes Signal Strength In % (to compare to alarm threshold level set by host control panel) and Compensation Level (ind1cat1on of beam status and dirt accumulation). Application note Reflernve beam smoke detectors may not be suitable for areas with highly renernve surfaces. Separate transmitter or receiver models may be required. Refer to NFPA 72 and contact your Autocall product representative for additional appl1cat1ons guidance. Accessory reference, images are not to scale Beam Detector on 1220-000 Uni-Box 23901 Pnsm Renector Page 2 1170-000 AdJUStment Bracker • • I I □ I ' I I One Prism on 1031-000 Mounting Bracket I I I . I I □: I Four Pnsms on 1031-000 Mount1ng Bracket AC4098-0049 Rev. 5 1/2020 ~AUTOCALL Auto-Aligning Reflective Beam Smoke Detectors with IDNec Communicac,ons Product selection and ordering information Table 1: Addressable beam detector selection SKU Description Dimensions IDNet Communications Addressable Reflernve Auto Align Beam Smoke Detector Controller System. ______________________ _,9 ¼" H X 7 rs" W x 2 13116" D (235 mm x 200 mm x 71 mm) A4098-9019 Includes: one A4098-9020 controller. one 5000-031 detector head. and one 23901 Head prism reflector. 5 9132" H x 5 YI 6 " W x 5 9132" D ( 135 mm x 134 mm x 132 mm) Controls up to two detector heads. Prism 4 Ys" x 3 1 YI 6" x %" D (105 mm x 100 mm x9.5 mm) A4098_9020 ID Net Communications Addressable Reflecnve Auto Align Beam Smoke Detector Controller only, 9 ¼" H x 7 "l's" w x 2 13116" D (235 mm for up~rade or replacement. Order detector heads and prism reflectors separately x 200 mm x 71 mm) ' Ordering Number" 5000-031 1210-000 1220-000 1170-000 5000-009 5000-010 1031-000 1040-000 1030-000 23901.01 1010-000 5000-014 1000-018 1000-019 1140-000 1141-000 1142-000 1143-000 1144-000 Table 2: Beam detector heads, prisms, and accessories Description ]Dimensions Additional Detector Head and Prism. se-lect up to one additional head for each A4098-9019 5 9132" H x 5 YI 6 " w x 5 9132" D ( 135 system. mm x 134 mm x 132 mm) Detector Surface Mount Uni-Box with conduit knockouts on all sides. White in color Universal back plate mounting. Captive screw lock on front plate. Mounting holes for the optional 1000-018 wire cage Use for SOOD and 3000 Series detector heads. Cover Plate. pre-drilled to mount the reflective detector head to a double gang electric box. White In color AdJustment Bracket for Motorized Reflernve Detector Heads, with 360 degree rotation and 140 degree adJustment. White in color Replaces the obsolete 5000-005 Bracket. Controller Back Box, surface or flush mount. Surface mount to single gang. double gang, or 4" square box Controller Back Box Semi-Flush Mount Trim Plate for the 5000-009 box. 8 7/16' H X 7 7/16" W x 1 ¾" D (214 mm x 189 mm x 45 mm) 10 5'16" H x 8 ¾" W (263 mm x 222 mm) Surface mount wall bracket for prisms Hole pattern for one or 'our prisms and designed to fit on Unistrut. Black in color Order prisms separately. Single Prism Alignment Adaptor Plate. pre-drilled to mount one prism Includes 1180-000 Universal Alignment Bracket. White in color The prism Is included with the reflecnve detector heads. Surface mount wall bracket for prisms with hole pattern for one or four prisms. and designed to fit on Unistrut. White in color. Order prisms separately. Replacement Prism Reflector. Long Range Prism Kit, includes three add1t1onal prisms for 1nstallat1ons between 164 ft and 328 ft (50m and 1 00m) Celling Pendant Mounting Bracket. Proternve Wire Cage for 5000 Series detector heads. Protective Wire Cage for 5000 Series controllers. Celling Pendant Mount for the reflernve detector head. supplied with a 12" long nipple Use for single or b1-d1rernonal applications. White In color Ceiling Pendant Mount for the end to end rransmmer and receiver units, supplied with a 12" long nipple Use for single or b1-d1rernonal applications White In color Celling Pendant Mount for the reflernve detector head, supplied with a 12" long nipple. Use for single or b1-d1rect1onal applications. Beige in color Celling Pendant Mount for a single prism, includes ceiling pendant and a single prism mounting plate. White In color Ceiling Pendant Mount for long throw prism kit, includes ceiling pendant and a four prism mounting plate White In color. Order the long throw prisms seperately. Controller display detail reference Page 3 AC4098-0049 Rev. 5 1/2020 Specifications Specification Housing Finish ~AUTO CALL Auto-Aligning Reflective Beam Smoke Detectors with IDNet Communications Table 3: Mechanical and general reference Rating Flame Retardant ABS, IP rating= IP54 Light grey/black Autocall Addressable Interface and Host Control Panel Programming Instructions Head and accessories reference 579-1039AC, add1t1onal operating and 1nstallat1on Instruct1ons ship with the product. Fire Fighting Enter_pnses (A Halma Group Company): website· www.ffeuk.com/ 1Specification Input voltage Input current Power wiring to controller Wiring, controller to head Beam optical wavelength Details Table 4: Electrical 1Rating 14 voe to 36 voe, supplied from agency listed fire alarm power supply. 50 mA Terminal block connections, 18 AWG to 14 AWG (0.82 mm2 to 2.08 mm2) 328 ft (100 m) maximum distance, use twisted wire pair; 18 AWG to 16 AWG (1 mm2 to 1.5 mm2 ) 850 nm IDNet addressable communications, communications cIrcuIt is isolated from input power, and controller-to-head communicanons. Communications reference Compatibility reference IDNet Communications source Firmware/revision (review for addition to installed systems) Compatible with all 4007ES, 401 0ES, and 41 00ES IDNet2 modules. Addressing Sensitivity threshold Operating distance range Beam status indicators Service status indicators Point types Trouble conditions UL listed temperature Range Operating temperature range Operating humidity range On-board DIP switch selects a base address to communicate with the local controller and the first beam detector head. For systems with two heads for each controller, the next sequential address Is automatically assigned Table 5: Operating Specifications Selectable from 10% to 60-%; with 35% as default (this Is % of beam obscuration drop from 100%). The value Is selected using the host fire alarm control panel and communicated by IDNet communicauons. 26 ft. 3 In. to 330 ft (8 m to 100 ml Muln-color LED on bottom front of beam detector head: Normal= Green; Alarm= Red Fault (Trouble)= Yellow; LED fiash Is every 10 seconos. One LED for each detector, located under the beam controller cover, indicates the status of the beam detector channel communicat1ons. Fire, Latched Supervisory, or Utility selected using the host fire alarm control panel Communications fault, Rapid Obscuration fault (blocked beam), Excessively Dirty, and Summary trouble (other general troubles not detailed) 32° F to 100° F (0° C to 38° C) -4° F to 131 ° F ( 20° C to 55° C), for indoor use only. 0% to 93% RH, non-condens,ng. it> 2020 Johnson Controls All rights reserved All speof,cauons and other ,rforrrat,on showr were cJrrent as of docJmer1 revIsIor and are SJbJect to crarge w1tl'0Jt notice Add1t1oral listings may be applicable contact yOJI local AutocaII prodJCt supplier for the latest status. Listings and approvals Jnder Tyco i:,re & Security Gmb-, and the product narres listed Ir this material are rrarks and101 registered rrarls. Unaurhonzed Jse Is stn::tly proh1b1ted "<=PA 72 and ",anor.al i:lfe Alarrr Code are registered traderrarks of tr,e t\a[loral ~ire Protewor AssocIat10I (t-.=PAJ AC4098-0049 Rev. 5 1/2020 .AUTO CALL UL, ULC Approved' TrueAlert Addressable Notification Appliances Wall Mount Weatherproof Visible and Audible/Visible Notification Appliances Features Figure 1: Weatherproof A/V (top) and Strobe (bottom), side view of A/Von Weatherproof Mounting Boxes (right) TrueAlen ES weatherproof addressable appliances provide v1s1ble and aud1ble/v1s1ble notification for indoor and outdoor. extended temperature and extended humidity applications. They are 1nd1v1dually addressed and receive power. supervIsIon. and control signals from an Autocall fire alarm control unit providing IDNAC Signaling Line Circuits (SLCs) Individually addressed and controlled multi-candela TrueAlert ES weatherproof notification appliances for extended temperature and humidity range provide: · Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control unit or jumper selected as 15, 75. WP 75, or WP 185 cd · Advanced addressable not1f1cat1on controlled by IDNAC SLCs providing regulated 29 voe allowing strobes to operate with lower current even under battery backup · Wiring supervision to each appliance allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) · Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control unit · T1 ueAlen Dev1Ce Reports at the control unit detailing appliance point ID. custom label, type, and candela semng · Magnet Test diagnostics to assist checkout and testing of appliances and wiring · Electrical test p01'1l access without removing cover LED Indicator and Magnet Test: · Appliance LED can be selected to display each polling cycle to 1nd1Cate appliance supervIsIon · When the controller Is In d1agnost1c mode the Magnet rest pulses the LED to indicate appliance address and can be set to also briefiy flash the strobe and sound the AN horn Mechanical design: · Rugged, high Impacr, flame retardant thermoplastic housing In red with white letters or white with red letters, with clear lens · Standard models are available with FIRE leue11ng or IJlank. configured models are available with add1t1onal lettering of FEU. FEU/FIRE. ALERT and blank · Mounting matches weatherproof boxes (required), ordered separately · Separate covers are available to change applicanon type on-site or for replacement · In/out wiring terminals for 18 AWG to 12 AWG -Enclosure Is rated NEMA 3R · Convenient wiring terminal access at front of housing Agency listings: · u L 1638 listed for outdoor applications with strobe rated at 75 cd (WP75) or 185 cd (WP185) • UL 1971 listed for indoor applications with strobe intensity selectable as 15 or 75 cd; indoor applicanons are compatible with ADA requirements · Horn operation Is listed to UL Standard 464 For A/V Models with horn: • Harmonically rich output sound for either coded or steady operation • Horns sound as Temporal Code 3, March Time pattern. continuous: or Temporal Code 4, controlled separately from visible appliances on the same two-wire circuit · Selectable March Time rates of 20. 60, or 120 beats per minute • Output Is "high" or "low" (-5 dBA difference) selectable at the appliance or from the controller with FACU mode selected at the appliance Strobe Application Reference Proper selernon of v1s1ble not1f1cat1on Is dependent on occupancy, locanon, local codes, and proper applications of. the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code BOCA, ICBO, or SBCCI, and the applicat1on guidelines of the Americans With Disabilities Act (ADA) TrueAlert ES Operation Separate visible and audible notification TrueAlen ES addressable appliances on IDNAC SLCs provide separate v1s1ble and audible notification using a single two-wire circuit that also :onf1rms connewon to the 1nd1v1dual nonfication appliance's electronic circuit This operation increases circuit supervIsIon integrity by prov1d1ng supervIsIon that extends beyond the appliance wiring connections Reduced current allows efficient IDNAC SLC operation Wirh IDNAC SLCs. a constant 29 VDC source voltage Is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage :Jrop margin under both primary power and secondary battery standby. Eff1c1enc1es include wiring distances up to 2 to 3 times farther than wnh convennonal not1ficat1on, or support for more appliances per IDNAC SLC. or use of smaller gauge wiring, or combinations of these benefits, all ;irov1ding 1nstallat1on and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm cond1t1ons Reduced Installation and Testing Time. With separate controls on rhe same two-wire SLC. 1nstallat1on nme and expense for both retrofit and new construrnon can be significantly 'educed. When Class B wiring Is used. wiring can be 'T' tapped. allowing -nore savings In distance wire, conduit (size and ut1l1zat1on), and overall 1nstallat1on efficiency. Use of Self-Test and Magnet Test features mp roves installanon efficiency. True Alen device reports conveniently dent1fy 1nformat1on about each connected appliance AC49WP-0001 Rev 5 11 /2016 TrueAlert ES Diagnostics Test Features ~AUTOCALL Wall Mou nt Weatherproof Visible and Audible/visible Notificat ion Appliances When IDNAC SLCs are 1n diagnostic mode, Self-Test and Magnet Test features provide 1nd1v1dual appliance testing. With the Self-Test feature, appliance operation can be confirmed without leaving the control unit. Add,uonally, eac, appliance's LED can be selected to pulse when it receives a superv1s,on poll during normal operanon Self-Test Details Selecttng Self-Test Mode from the control unit allows on-board sensors, depe1ding on the device type, to detect its own strobe and/or horn output and then report their status to the control unit. Operation 1s by selected VNAC appliance groups and ,s either automatic (all briefly simultaneously arnvated) or individually acttvated by applying a magnet. Silent Appliance Magnet Test In this test mode, ,n response to the application of a magnet, the appliance LED pulses sequentially to conveniently ,nd,cate the appliance's address. Operational Appliance Magnet Test In this test mode, after the address 1s 1nd1cated by pulsing the appliance LED, the strobe will briefly flash and the NV horn will briefly sound to indicate proper operation TrueStart Instrument Two (TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to ,ts ability to test IDCs, NACs, and IDNet communications before connernon to the control unit. Please contact your local Autocall representative for add1t1onal 1nformat1on. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 1s available for remote mounting on TrueAlen addressable circuits to isolate short circuited wiring from funrnon,ng wiring. Refer to data sheet AC4905-0001 for addmonal information. Page 2 AC49WP-0001 Rev. 5 11 /2016 ~AUTO CALL Wall Mount Weatherproof Visible and Audible/Visible Notification Appliances Weatherproof Appliance Installation Cover tot mounting bo(3x) \ 11~-=--------~ Knockouts top, bottom, sides, and back; 5 total moun mg screws r--:-..,,---..., H . (AN '1 1(,,) -Weatherproof mounting box (required) ousmg shown)--.....___ f ,____ ~11 I ".... / Ill . j '"'ir~'') Housing to mounting \ 7';,-/ W -"-;.., I· box screws (2) i ,'["::rf ----':: \.-,;::......_ , ~ · [ [~ ?,. Perimeter gasket, pre-installed ,t).. ''--~ ~>i I .. ' J --, ;// i:;, 1:: ·<I• -t~ !l '~~1 /~,_J_ ~--·1 • I ---, j -------------.,i~~, -. j' J ' °' A L-~-1~ I ----------u 1111,___Th_ (3) ~ altachmoot tabs . , .,·-~--------~\, located bottom, left and nght side ( ' '. ,-:. ~ ~ -Internal cover gasket ---•, is pro-installed Strobe intensity viowing slot Standard cover ------(AN shown) Magnot tost location (bottom of housing) Figure 2: Weatherproof Appliance Installation Dimension and Mounting Height Reference 5-3/8" (137 mm 5-9/16. (141 mm) between mounting holes 1+-----0-1/8" (156 mm1-----i LED Indicator 1J,, (140 mm) otal height 4-1/2" '-__ ... Im) 4-11/32" (110 mm) total depth 1-21/32" (42 mm) Figure 3: Dimension and Mounting Height IDNAC SLC Controller Compatibility Reference Table 1: IDNAC SLC Controller Compatibility Reference Intensity selection plug, accessible only from rear of housing; factory setting is FACP, selected from fire alarm control panel: UL 1971 listed model settings are 15 or 75 cd; UL 1638 listed model settings are \NP75 (75 cd) or \NP185 (185 cd) IMPORTANT! INDOOR WAJ.L MQWil MOUNTING ~ REFERENCE T NFPA 72 requires that the entire lens be not less than 80" and not greater than 96" above the finished floor I 81" (2.06 m) minimum to mounting tabs Compatible Controllers Data Sheet AC4100-0100 AC4009-0004 AC4007-0002 AC4010-0011 -~IDNAC SLC Output Controller Output Voltage Appliance Voltage 41 00ES with EPS+ or EPS Power Supply 4009 IDNAC Repeater 4007ES With IDNAC Not1f1cat1on 401 DES with ESS Enhanced System Supply Page 3 IDNAC SLC 23VDC 29 VDC (regulated) (wnh 6 VDC drop) AC49WP-0001 Rev 5 11 /2016 ~AUTO CALL Wall Mount Weatherproof Visible and AudibleNisib le Notification Appliances Product Selection Table 2: UL Listed TrueAlert ES Addressable Weatherproof Notification Appliances Type SKU Cover Color "FIRE" Lettering Description Intensity Ratings Strobe (V/O) A49VO-APPLW-O order cover separately I UL 1971 'UL 1638 ~75 cd (setting 1 S cd or 75 WP7S) or Horn/Sr robe (AN) A49AV-APPLW-O order cover separately UL listed weatherproofTrueAlert ES addressable appliance; requires weatherproof box, see below cd 185 cd (setting WP185) Note: Separate covers are required whe'n ordering A49VO-APPLW-O or A49AV-APPLW-O. Table 3: Wall Mount Weatherproof Boxes (Required) SKU A49WPBB-AWOWR A49WPBB-AWOWW Color Red White Description Dimensions Surface Mount Weatherproof Mounting Box (required) S ½" H x 6 lii" W x 1 %" D (140 mm x 156 mm x 41 mm) Wording FIRE ALERT Blank I Red VO Cover Models A49VOC-WRFIRE-O A49VOC-WRAL T-O A49VOC-WRS-O Specifications Specifications Typical Operating Voltage Range Supervisory Requirements IDNAC SLC Loading Temperature Range Hum1d1ty Range UL 1971 Listed Rating UL 1638 Listed Rating UL 1971 Listed Rating UL 1638 Listed Rating IDNAC SLC Wiring Spec1f1cations (refer to control panel installanon Instruct1ons for more 1nformat1on) Connecuons Installation Instructions Sound Type Reverberant Chamber. UL 464 Test Anechoic Chamber, ULC 525 Test Table 4: Separate Covers Red AV Cover Models A49AVC-WRFIRE-O A49AVC-WRALTO A49AVC-WRS-O White VO Cover Models A49VOC-WWFIRE-O A49VOC-WWAL T-O A49VOC-WWS-O Table 5: Electrical specifications Rating 23 VDC to 31 VDC Special Appl1cat1on 1 unit load(= 0.8 mA control panel current) Maximum of 127 addresses per SLC. 139 unit loads 32 °F to 120 °F (0 °c to 49 °C): 1 S or 75 cd semng -31 °F to 150 °F ( 35 °c to 66 °C), WP75 or WP185 cd setting I 0% to 93%, at 100 °F (38 °C) up to 98%, at 104 °F (40 °() UTP, unshielded twisted pair recommended White AV Cover Models A49AVC-WWFIRE-O A49AVC-WWS-O Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance= 4000 ft (1219 m) Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm\ two wires per terminal for in/out wiring 5791032AC Table 6: A/V Horn Output Ratings @ 10 ft (3 m)@ 23 voe Steady/High 813dB 874 dB Steady/Low 73.8 dB 81.0 dB Coded/High 76.4 dB 87.2 dB Coded/Low 69.9 dB 80.6 dB Note: UL 464 test coded values are typical of the output measured with a Te'Tlporal or a March Time pattern and with a sound level meter reading on a "fast" sewng Under the same test cond1t1ons. coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output rat· Ings are typically more representative of acrual installed sound output. Table 7: 23 voe RMS Current Ratings Model Rating Temperature Candela Setting Current 32 °F to 120 °F (0 °( lO 49 1 S cd 60 mA UL 1971 Ratings oc) 75 cd 160mA V/O Models 32 °F to 1 so °F (0 °( to 66 WP75 cd 160mA UL 1638 Ratings oc) WP185 cd 185mA Page 4 AC49WP-0001 Rev.S11/2016 -AUTO CALL Wall Mount Weatherproof Visible and Audible/Visible Notification Appliances Model AN Models, horn on continuous, high setting Rating UL 1971 Ratings UL 1638 Ranngs Table 7: 23 VDC RMS Current Ratings Temperature Candela Setting -31 °F to below 32 °F (-35 •c WP75 cd too °Cl WP185 cd 32 °F to 120 °F (0 °C to 49 ·c, 32 °F to 150 °F (0 °C to 66 ·cJ -31 °F to below 32 °F (-35 °C too °CJ 15 cd 75 cd WP75 cd WP185 cd WP75 cd WP185 cd Table 8: UL 1638 WP75 and WP1 85 Light Output Reference Angle On-Axis Vertical, Below Axis o• 45° 90° WP75 Minimum Candela Rating (over temp. range) 75 cd 69 cd 17 cd WP75 Typical Candela at 77 °F (25 °C) 142 cd 86 cd 22 cd WP185 Minimum Candela Raring (over temp. range) 185 cd 90 cd 21 cd WPl 85 Typical Candela at 77 °F (25 °() 220 cd 112 cd 27 cd Level Decrease Horizontal Angle AN Sound D1spers1on per ULC-S525 Anechoic testing -3 dB +50° (to right) performed at 3 m (10 ft), referenced to on-axis= 0° -40° (to left) 6dB +85° (to right) -85 ° (to left) Page 5 Current 212 mA 239mA 80mA 165mA 163mA 189 mA 238 mA 274mA Horizontal. Left/Right of Axis 45° 90° 60 cd 28 cd 74 cd 35 cd 81 cd 40 cd 101 cd 50 cd Vertical Angle +55° (above axis) -70° (below axis) +60° (above axis) -90° (below axis) AC49WP-0001 Rev 5 11 /2016 -AUTOCALL © 2018 Johrsor Controls All rights reserved. All spec,r,cat,or,s and otrer ,nforrrauor srowr were currert as of docurrert revision and are sJbJect to crarge w1th0Jt nottce Add1t1oral lisur,gs rra1 be appl,cable. cortact yoJr local Autoca11 product sJppl,er for the latest stat JS List,r,gs ard approvals Jnder Tyco i:,re & SecJnty Gmb.-,. and the prod,JCt narres listed ,r tr,s material are marks and1or registered marks. uraJthon:ed JSe ,s strictly prohibited I\ =PA 72 ard l\at,onal =,re Alarm Code are 1eg1stered traden,arks of tre \at,onal =ire Protewor Assoc,ation (N•PA) AC49WP-0001 Rev 5 11 /2016 .AUTO CALL UL. ULC Listed· TrueAlert ES Addressable Notification Appliances AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe, Model Series A49AV Description Ceiling Mount Addressable Visible (A/V) Notification Appliances are 1nd1v1dually addressed aud1ble/v1s1ble not1ficat1on appliances Lhat receive power.supervision, and control signals from an Autocall fire alarm control panel providing I DNAC Signaling Line Circuits (SLCs) LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. (See TrueAlen ES AN LEGACY Compaub1ilty Reference.) Features Individually addressed and controlled multi-candela TrueAlert ES A/V (audible/visible) notification appliances provide: · Multi-candela xenon strobe with synchronized 1 Hz nash rate and with IntensIty programmable from the control panel or Jumper selected as 15, 30. 75 or 11 0cd on the AV model. or 110, 135 or 185 cd on the AVH model · Advanced addressable not1ficauon controlled by IDNAC SLCs. · IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current · Wiring supervIsIon to each appliance allowing "T-tapped" connernons for Class B rncuIts to simplify wIrIng (Class A circuits require 1n/out wiring) · Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel · TrueAlert Device Reports at the control panel detailing appliance point ID. custom label. type, and candela semng (see sample In TrueAlen Device Report<. Reference) · Magnet Test diagnostics to assist checkout and testing of appliances and wiring · Electrical test point access by removing the cover · Compat1bil1ty with ADA requirements: (refer to important 1nstallat1on 1nformat1on in Installation Reference) · Compat1bil1ty with legacy TrueAlen addressable systems for upgrade and replacement (see TrueAlert ES AN LEGACY Compat1b11it1 Referen e) · Strobe operation Is listed to UL Standard 1971 and ULC Standard S526; Horn operat1on Is listed to UL Standard 464 and ULC Standard S525 LED Indicator and Magnet Test feature: · Appliance LED can be selected to display each polling cycle to 1nd1cate appliance supervision · When the controller Is In d1agnosnc mode, the Magnet Test pulses the LED to 1nd1care appliance address and can be ser to also briefly flash the strobe and sound the horn Mechanical design features · Rugged, high impact. name reLardant thermoplastic housing In red with white letters or white with red letters, with clear lens. available with FIRE. FEU. ALERT. FEU/FIRE.. or blank lettering · Separate covers are available to change applrcauon rype onsIre or for replacement · You can use a back box to mount the appliance assembly to the wall. Mount to a 4-inch (10.16 cm) square electrical box · Covers can be easily removed without d1sturb1ng the connected housing and avo1d1ng trouble conditions · In/out wiring terminals for 18 AWG to 12 AWG · Optional red wire guards (see Product '>E-lecuon) Audible notification appliance (horn): · Harmonically rich output sound for either coded or steady operation · Horns sound as Temporal Code 3. March Time pattern. continuous; or Temporal Code 4. controlled separately from v1s1ble appliances on the same two-wire circuit · Selectable March Time rates of 20. 60. or 120 beats per minute · Output Is "high" or "low" (-5 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance Figure 1: TrueAlert ES Addressable A/V Strobe Application Reference Proper selection of visible notification Is dependent on occupancy. location. and local codes. TrueAlert ES Operation Advantage TrueAlert ES addressable appliances on IDNAC SLCs provide separate v1s1ble and audible notification using a single two- wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervIsIon IntegrIty by providing supervIsIon that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs With IDNAC SLCs. a constant 29 voe source voltage Is maintained. even during battery standby, allowing strobes ro operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional nor1frcarron. or support for more appliances per IDNAC SLC. or use of smaller gauge wiring. or combrnatrons of these benefits. all prov1d1ng installation and maintenance savings with high assurance that appliances that operate during normal system testrng will operate during worst case alarm condrt1ons. Reducing Installation and Testing Time With separate controls on the same two-wire SLC. 1nstallauon time and expense for both retrofit and new construrnon can be s1gnrficantly reduced. When Class B wIrIng Is used. wiring can be 'T' tapped. allowing more savings In distance. wire. conduit (size and ut1lrzation), and overall 1nstallat1on effrc1ency. Use of Self Test and Magnet Test features improve 1nstallat1on efficiency. TrueAlert device reports conveniently 1dent1fy information about each connected appliance S49AVC 0001 Rev 7 10/2018 ~AUTO CALL Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe, Model Series A49AV TrueAlert ES Diagnostics Test Features When IDNAC SLCs are In d1agnost1c mode. Self-Test and Magnet Test features provide 1nd1v1dual appliance testing. With the Self-Test feature. appliance operation con be confirmed without leaving the control panel. Add1t1onally, each appliance's LED can be selected to pulse when It receives a supervision poll during normal operation. Self-Test Details Selecting Self-Test Mode from the control panel allows on-board sensors, depending on the device type, to detect its own strobe and/or horn output and then report their status to the control panel. Operation Is by selected VNAC appliance groups and Is either automatic (all briefly simultaneously arnvated) or 1nd1v1dually arnvated by applying a magnet. (Refer to control panel data sheet for more Self-Test information, see 11st in Table 10.) Silent Appliance Magnet Test In this test mode, In response to application of a magnet, the appliance LED pulses sequentially to conveniently 1nd1cate the appliance's address. Operational Appliance Magnet Test. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash and the horn will briefly sound to 1nd1cate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Aurocall representative for add1tronal information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 Isolator Model A4905-9929 Is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wInng. (See data sheet AC4905-0001.) Installation Reference I \ Appliance test points, audio circuit power taps, and address dip switch Set audio circuit power taps and device address before fixing cover in place. Candela flag setting Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set the flag to the desired candela rating. Appliance with cover (front) Mount to 4" X 4" X 1-1/2" Appliance (rear) electrical box using 8-32 r Wiring terminals for horn and strobe connections accept 2 #12-18 AWG wires Use slotted screwdriver here to remove cover TrueAlert Device Reports Reference Service Port Page 1 REPORT 5 : TrueAlert Device Reoort 12:34 :56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA Tl4-1-l Location Label up to 40 characters V/0 15 Tl4-l-2 Break Room 5 A/V llO Tl4-1-3 Boiler Room A/V 75 Tl4-l-4 Elec. Room 7 A/V 135 Page 2 S49AVC-0001 Rev 7 10/2018 ~AUTO CALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe, Model Series A49AV Product Selection Ceiling Mount Addressable Audible/Visible (A/V) Appliances TrueAlert ES Addressable AN appliance dimensions with cover. 8 Ys" H x 7 Ys" W x 3" D ( 206 mm x 180 mm x 76 mm) Table 1: Ceiling Mount Addressable Visual Only V/0 Appliances SKU* Lens color Description Clear A49AV·APPLC A49AV-APPLC-BA A49AVH-APPLC A49AVH-APPLC-BA A49AVH-APPLCA A49AVH-APPLCA-BA A49AVH-APPLCB A49AVH-APPLCB·BA AV appliance only. Select cover separately. [SKU A49WPBB-SVCR A49WPBB-SVCW Amber Blue Table 2: Back boxes Color Red White Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. ~KU* A49AVC-CRFIRE A49AVC-CWFIRE A49AVC-CRALT A49AVC-CWAL T A49AVC-CRBM A49AVC-CWBM A49AVC-CRS A49AVC-CK A49AVC-CRFEU A49AVC CWFEU A49AVC CRBAF A49AVC-CWBAF A49AVC-CRBF A49AVC-CWBF A49AVC-CWS A49AVC-CWCALT SKU A49WG-SVWCR A49WGBB-SVCR-O Page 3 Table 3: Separate Covers (Required when ordering model 49AV-APPLC(-BA)) Color Wording Red White Red White Red White Red Black Red White Red Whne Red White White White FIRE ALERT )..G)/ALERT Autocall logo only Blank FEU J!r lFIRE FEU/FIRE Autocall logo only ).'._'if/FIRE Table 4: Wire Guards and Wire Guard Back Boxes Description AV Ceiling Moun· Red Wire Guard AV Ceiling Moun: Red Wire Guard Back Box S49AVC-0001 Rev 7 10/2018 -AUTOCALL Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe, Model Series A49AV TrueAlert ES AN Specifications Specification Typical Operating Voltage Range Supervisory Requirements IONAC SLC Loading [sound Type/Setting Reverberant Chamber. UL 464 Test Voltage 23 31 Anechoic Chamber. ULC 23 525 Test 31 Rating Table 5: Electrical Ratings Rating 23 voe to 30 voe. Special Application 1 unit load(= 0.8 mA control panel current) Maximum of 127 addresses per SLC Table 6: Sound Output Ratings@ 10 ft (3 m) (with IDNAC SLCs) Steady/High }teady/Low Coded/High 89.0 dBA 83 dBA 85 dBA 91 dBA 97 dBA 99dBA 85.5 dBA 92.5 dBA 95 dBA 87 dBA 97 dBA 99 dBA Table 7: Sound Output Dispersion per ULC SS41 Anechoic Testing Coded/Low 80dBA 82 dBA 92.5 dBA 95dBA Specification Horizontal Vertical -3 dBA@ 30° at both left and right from center; -6 dBA@ 80° from center -3 dBA@ 25° above and 35° below center; -6 dBA@ 65° above and below center Candela 15 cd 30cd 75 cd 110 cd 135 cd 185 cd Setting A49AV 23-30VDC 67mA 92mA 159 mA 215mA A49AVH 300mA 330mA 391 mA Table 8: General Specifications [Specifications Sound Characteristics Temperature Range Hum1d1ty Range Installation Instructions C onnect1ons IONAC SLC Wiring Spec1f1cat1ons (refer to control panel installation instructions for more information) Ratings 2406 to 3700 Hz sweep, modulated at 120 Hz rate 32° to 120° F (0° to 49° C) 10% to 93%. non-condensing@ 104° F (40° C) 5791242AC Terminal blocks on mounting plate for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2): two wires per terminal for in/out wiring UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 1 0,0QQ fl (3048 m) Maximum wire length to any appliance= 4000 ft (1219 m) Note: UL 464 test coded values are typical of the output measured with a Temporal or a March Time pattern and with a sound level meter reading on a "fast" semng. Under the same test cond111ons. coded horn output "peak" sound level readings are typically 4 dBA higher Anechoic horn output rat- ings are typically more representative of actual installed sound output. IDNAC SLC Controller Compatibility Reference Table 9: Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 41 DOES with EPS+ or EPS Power Supply AC4100-0100 4009 IONAC Repeater AC4009-0004 29VOC 23VOC IONAC SLC 4007ES With IONAC Not1f1cat1on AC4007 0002 (regulated) (With 6 voe drop) 4010ES with ESS Enhanced System Supply AC4010-0011 Page 4 S49AVC 0001 Rev. 7 1012018 -AUTO CALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe, Model Series A49AV TrueAlert ES AN LEGACY Compatibility Reference Compatible Controller 41 00ES With TrueAlert Power Supply 4009 TPS, Remote TrueAlert Power Supply* TrueAlen Addressable Controller (4009T)* Table 10: Compatibility Reference [Available Strobe Data Sheet Reference Controller Output Intensity AC4100-0031 AC4100-0037 AC4009-0003 TrueAlen Addressable SLC I 5, 30, 75, and 110 cd Continuous, Temporal Appliance Voltage Minimum Code 3, and March Time 17 voe of 60 or 120 bpm Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) voltage Range 17 voe to 31 voe Special Application Sound Type/Setting Steady/High Steady/Low Reverberant Chamber, Sound Output Ratings UL 464 Test 87.0 dBA @ 1 o ft (3 mJ @ 1 7 voe Anechoic Chamber, ULC 945 dBA 525 Test Candela Setting 15 cd 17 voe RMS Current Ratings, with horn on cont1nuousat high semng, use when connected 74 mA to TrueAlertAddressable SLCs per above *Nol compatible with A49AVH-APPLC Page 5 81.0 dBA 90.0 dBA 30 cd 8SmA Coded/High 82.0 dBA 94 5 dBA 75 cd 140 mA Coded/Low 770dBA 90.0 dBA 110 cd 185 mA S49AVC-0001 Rev 7 10/2018 ~AUTO CALL Aud ible/Visible Notification Appliances, Indoor Ceiling Mount Mult i-Candela Horn/Strobe, Model Series A49AV (t 2018 Jorrsor Controls. All rights reserved All spec1f1cattons and other 1nforrrat1or shown were current as of docJmert rev,s,on and are sJbJect to charge w1th0Jt rotice Add1t1oral lIsurgs rray be applicable. cortact yoJr local AJtocall product SJppl,er for tre latest status. L1st1rgs and approvals Jnder Tyco ;:,re & SecJrtty Gmb~, ard tre prod.1ct narres listed Ir this rratert2I are marks and1or registered rrarks. UraJtrorized Jse ,s strictly prohibited. \FPA 72 ard \at1oral Fire Alarrr Code are reg,scered traderrarks of tre '-,at1oral ,,re Prmernor Assoc,at,or (\=PA). S49AVC 0001 Rev. 7 10/2018 .AUTO CALL UL. ULC Listed· TrueAlert ES Addressable Notification Appliances Audible Only Notification Appliances, Indoor Ceiling Mount Electronic Horns, Model Series A49AO Features Individually addressed and controlled low power TrueAlert ES A/O (audible only) Notification Appliances: · Advanced addressable notification controlled by IDNAC SLCs · IDNAC SLCs provide regulated 29 voe allowing horns to operate with lower current · Wiring supervIsIon to each appliance allows "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) · Self-Test Mode allows an on-board sensor to detect the horn output and then report its status to the control panel · Horns are controlled separately from visible appliances on the same SLC with control panel selection of operation as: Temporal Code 3. March Time (selectable as 20, 60, or 120 bpm), Continuous, or Temporal Code 4 · Output of "high" or "low" (-6 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance · Unobtrusive Magnet Test diagnostics are available to assist checkout and testing of appliances and wiring · Electrical test point access by removing the cover · Compatible with legacy TrueAlert addressable systems for upgrade and replacement (see TrueAlert ES Horn LEGACY Compat1b1l1t1 Reference) · Listed to UL Standard 464 and ULC Standard S525 LED Indicator and Magnet Test feature: · Appliance LED can be selected to display each polling cycle to 1nd1cate appliance supervision · When the controller Is In diagnostic mode. the Magnet Test pulses the LED to 1nd1cate appliance address and Is selectable to also briefly sound the horn ro confirm operation Mechanical design features include: · Rugged, high impact. flame retardant thermoplastic housing In red with white letters or white with red letters available with FIRE, ALERT. FEU. or blank lettering · Separate covers are available to change application type on-site or for replacement, covers can be easily removed without disturbing the connected housing and avo1d1ng trouble condmons · You can use a back box to mount the appliance assembly to the wall. Mount to a 4 inch [10.16 cm) square electrical box In/out wIrIng terminals for 18 AWG to 12 AWG · Opllonal wire guards (see Table 4) y /d·l111 ,r I h .1,r I l 1~ 1 Ii l,l, r I 1 y u I I A 11 II 1,1 t J 1 111 h•, I I ti I ,, 1 I, I J Figure 1: TrueAlert ES Addressable Horns are Available in Red with White Lettering and White with Red Lettering Description TrueAlert ES addressable horns TrueAlert ES addressable horns are 1nd1v1dually addressed audible not1f1cat1on appliances that receive power. supervision. and control signals from an Autocall fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See Table 5.) TrueAlert ES Operation Advantage TrueAlert ES addressable appliances on IDNAC SLCs provide separate audible (and visible) notification using a single two-wire circuit that also confirms connection co the individual notification appliance's electronic circuit This operation increases cIrcuIt supervIsIon integrity by providing supervIsIon that extends beyond the appliance wiring connewons. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs. a constant 29 VDC source voltage Is maintained. even during battery standby, allowing horns on the same SLC to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Eff1cienc1es include wiring distances up to 2 to 3 nmes farther than with conventional not1f1cat1on. or support for more appliances per IDNAC SLC. or use of smaller gauge wiring, or combinations of these benefits, all prov1d1ng installation and maintenance savings with high assurance tha' appliances lhal operate during normal system tesnng will operate during worst case alarrn condmons Reducing Installation and Testing Time. W1[r separate controls on the same two-wire SLC. 1nsrallat1on nme and expense for both retrofit and new consrruwon can be s1gnif1cantly reduced When Class B wiring Is used wiring can be 'T tapped. allowing more sawigs In d1slance, wire, conduit (size and util1zat1on). and overall 1nsrallat1on efficiency. Use of Self Test and Magnet Test features improves 1ns1allat1on efficiency. TrueAlen device reports conveniently 1dent1fy 1nformat1on about each connected appliance AC49AOC 0001 Rev. 3 512018 -AUTO CALL Audible Only Notification Appliances, Indoor Ceiling Mount Electronic Horns, Model Series A49AO TrueAlert ES Diagnostics Test Features When IDNAC SLCs are In diagnostic mode, Self-Test and Magnet Tesr features provide 1nd1v1dual appliance testing. With the Self-Tesr feature, appliance operorion con be confirmed wirhour leaving rhe control panel. Additionally, each appliance's LED can be selecred to pulse when It receives a supervIsIon poll during normal operation. Self-Test Details Selecting Self-Test Mode from the control panel allows on-board sensors, depending on the device type, to detect its own horn output and then report their status to the control panel. Operation Is by selected VNAC appliance groups and Is either automatic (all briefly simultaneously activated) or 1nd1v1dually arnvated by applying a magnet. (Refer to control panel data sheet for more Self-Test 1nformat1on, see list In IDNAC SLC Cont'oller Compat1b11ity Reference.) Silent Appliance Magnet Test. In this test mode, In response to application of a magnet, the appliance LED pulses sequentially to conveniently 1nd1cate the appliance's address. Operational Appliance Magnet Test. In this test mode, after the address Is indicated by pulsing the appliance LED, the horn will briefly sound to 1nd1cate proper operation. Truestart Instrument Two (TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances t0 its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Autocall representative for add1t1onal information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 Isolator Model A4905-9929 Is available for remote mounting on TrueAlert addressable rncuIts to isolate short circuited wiring from functioning wiring. (See data sheet AC4905-0001.) Product Selection Ceiling Mount Addressable Audible Only A/0 Appliances TrueAlen ES Addressable NO appliance dimensions with cover: 7 Va" H x 7 Ya" W x 1 W' D ( 180 mm x 180 mm x 32 mm) SKU* A49AO-APPLC A49AO-APPLC-BA SKU A49WPBB-SOCR A49WPBB-SOCR Table 1: Audible Only A/0 Appliances 1oescription AO appliance only. Select cover separately Table 2: Back boxes Color --L Red White Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof SKU* A49AOC-CRFIRE A49AOC CWFIRE A49AOC-CRALT A49AOC-CWALT A49AOC-CRFEU A49AOC-CWFEU A49AOC-CRBF A49AOC-CWBF A49AOC-CRBAA A49AOC-CWBAA A49AOC-CRBAt A49AOC-CWBAF A49AOC CK A4 9AOC-CWCAL T Page 2 Table 3: Separate Covers (Required when ordering model A49AO-APPLC(-BA) Color Wording Red White Red White Red White Red White Red White Red White Black White FIRE ALERT FEU FEU/FIRE )-'-WALERT J<;>IFIRE Blank *Bl/FIRE AC49AOC-0001 Rev 3 5/2018 ~AUTO CALL Audible Only Notification Appliances, Indoor Ceiling Mount Electronic Horns, Model Series A49AO Table 3: Separate Covers (Required when ordering model A49AO-APPLC(-BA) SKU* A49AOC-CRS A49AOC-CWS Color Wording Red White Autocall logo only Note: * Model numbers ending in -BA, APPLC models, and separate mounnng plates are assembled In the USA [SKU A49WG-SOCR Table 4: Wire Guards and Wire Guard Back Boxes Description SO Ceiling Mount Red Wire Guard TrueAlert Device Reports Reference Service Port REPORT$ : TrueAlert Device POINT ID CUSTOM LABEL T14-l-l Location Label Tl4-l-2 Break Room$ Tl 4-l-3 Boiler Room T14-l-4 Elec. Room 7 Installation Reference Reoort 12:34:56am DEVICE up to 40 characters Figure 2: Device Reports Reference TYPE CANDELA V/O 15 A/V llO A/V 7!:, A/V 135 Appftance Rear Address setting DIP swlleh. Accessible 1nrougn the apoliance IDNAC SLC Controller Compatibility Reference Table 5: Compatibility Reference Pagel TUE 27 Jan-15 Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage 41 00ES with EPS➔ or EPS Power Supply 4009 IDNAC Repeater 4007ES Wl[h IDNAC l~ot1f1car1on 401 0ES with ESS Enhanced System Supply Page 3 Reference AC 4100-0100 AC4009-0004 IDNAC SLC AC4007-0002 AC4010-0011 Voltage Design Reference 29VDC 23 VDC (regulated) (with 6 VDC drop) AC49AOC-0001 Rev 3 512018 ~AUTO CALL Audible Only Notification Appliances, Indoor Ceil ing Mount Electronic Horns, Model Series A49AO TrueAlert ES Horn Specifications Specification Typical Operating Voltage Range RMS Current Rating Supervisory Requirements IONAC SLC Loading Table 6: Electrical Ratings Rating ----- "23 voe to 30 voe, Special Application (see below for 17 voe ratings) 18 mA maximum@ 17V or 23V rating voe 1 unn load(= 0.8 mA control panel current) Maximum of 127 addresses per SLC, 139 unit loads Table 7: Sound Output Ratings @ 10 ft (3 m)@ 23 VDC (with IDNAC SLCs) --~~-~~-----~-~~ Sound Type/Setting Steady/High .steady/Low Coded/High Coded/Low Reverberant Chamber. UL 89_0 dBA 83.0 dBA 85 dBA 464 Test 80 dBA Anechoic Chamber, ULC 525 97_0 dBA Test 92.5 dBA 97.0 dBA 92.5 dBA Table 8: Sound Output Dispersion per ULC S541 Anechoic Testing [specification Horizontal Vertical Rating -3 dBA@ 4·5° at both left and right from center; -6 dBA@ 85° from center -3 dBA @45° above and 35° below center; -6 dBA@ 85° from center Table 9: General Specifications [specification Sound Characteristics Temperature Range Hum1d1ty Range Connections Installation lnstrucnons Installation Instructions 5791242AC IONAC SLC Wiring Spec1f1cat1ons (refer to control panel installation Instrucnons for more information) 2400 to 3700 Hz sweep, modulated at 120 Hz rate 32° to 120° F (0° to 49° CJ 10% to 93%, non-condensing@ 104° F (40° C) Terminal blocks on mounting plate for 18 AWG to 12 AWG (0 82 mm2 to 3.31 mm2). two wires per terminal for in/out wiring 579-1242AC UTP, unshielded twisted pair recommended Maximum wire length allowed with "T Taps" for Class B wiring per SLC = 1 0.000 ft (3048 m) Maximum wire length to any appliance= 4000 ft (1219 m) Note: UL 464 test coded values are typical of the output measured with a Temporal or a March Time pattern and with a sound level meter reading on a "fast" semng. Under the same test condl[lons. coded horn output "peak" sound level read ings are typically 4 dBA higher Anechoic horn output rat- ings are typically more representative of actual installed sound output. TrueAlert ES Horn LEGACY Compatibility Reference Compatible Controller 41 00ES with TrueAlert Power Supply 4009 TPS. Remote TrueAlen 17 VOC Power Supply TrueAlen Addressable Controller (4009T) Data Sheet Reference AC4100-0031 AC4100-0037 AC4009-0003 Table 10: Compatibility Reference Controller Output TrueAlert Addressable SLC Available Horn Control Continuous, Temporal Code 3. and March Time of 60 or 120 bpm Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 17 voe to 31 voe, Special Application Sound Output Ratings@ 10 ft (3 m)@ 17 voe Sound Type/Setting Steady/High Reverberant Chamber. UL 464 Test 87 dBA Anechoic Chamber, ULC 525 945 dBA Test Steady/Low Coded/High 81 dBA 82 dBA 90dBA 90dBA Appliance Voltage Minimum 17 voe Coded/Low 77 dBA 83.6 dBA i 2018 Jo~rsor Controls. All rights reserved All spec1f1cat1ors ard other 1nforrr ilt1or sloowr were urrent as of doCJmert rev1s1or and are SJbJeCt lD crarge w1thOJl not,ce Add1t1oral l1surgs rray be applicable cortact yoJr local AJtocall product sJppl1er for rre latest status. Llst1rgs ard approvals CJnder Tyco Fire & Sernnty Grrb-. and tre prodJct rarres listed 1r tlo1s rratenal are rrar,s andtor registered rrarks urautr,orized Jse 1s strictlj prohibited \FPA TJ. c1nd \ilt1ora1 Fire Alarrr Code are registered traderrarks of tre 'sat1oral •ire Protecnon Assoc1at1or l\"PA) AC49AOC 0001 Rev. 3 512018 I I I I I I I I I I :iiiiiiiiiiiiii~-~ _ illllliiiil' DMP.COM o o e o o G ®DMPALARMs • Provide dual path monitoring center communication for any burglary, commercial fire, or residential fire panel • DualComWZ and DualComNF enable basic remote panel control via Virtual Keypad'" app • Provides end user alerts of arming/disarming, alarm, and other events • Add Z-Wave· control of lights, locks, and thermostats with DualComWZ FEATURES • Fully supervised universal alarm communication over LTE, Wi-fi, or network ► AT&T or Verizon networks ► Program your own account number to easily work around locked panels ► External SMA antenna • Use Contact ID dialer capture, four input zones, or bell monitoring ► Wiring for Ademco ECP Bus ► Communicates with DMP SCS-lR and SCS-VR Receivers ► Armed/disarmed status LED • Private labeling available on the light pipe insert • Two output terminals with multiple output options ► Program Honeywell~ VISTA® panel through DualCom using Compass® WORKS WITH MOST PANELS If the existing panel supports Contact ID, it's a candidate for upgrading with DualComWZ or DualComNF. There are no issues with lockout codes. Simply add the DualCom unit to the existing installation and program in your own account number. UPGRADING HONEYWELL VISTA PANELS The DualCom modules can be programmed to easily takeover Honeywell VISTA panels. The communicator can connect to a VISTA series ECP bus, which will allow you to program the Honeywell panel remotely using Compass. AVAILABLE BURGLARY COMMUNICATION The DualComWZ provides control of basic panel security functions and video. It adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats. and more. FIRE COMMUNICATION The DualComNF offers network and cellular fire communication on any fire control panel via Contact ID captures or zone inputs. Meets NFPA 72 Standard for Single Communication Technology. FIRE PANEL TAKEOVER DualComNF provides two tip and ring to easily takeover existing fire panels with two phone lines. MOBILE SYSTEM CONTROL With DualCom communicators, you can update your customers' older residential and commercial systems to the latest cellular communication links. With cellular in place, users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile devices not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices. ENABLE VIDEO ON THE APP With the DualCom communicators, you can add up to six video cameras. Via the Virtual Keypad app, users can remotely view their premises to cancel or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION DualCom allows alarm messages to be communicated to an SCS-lR or SCS-VR Receiver over network or over Verizon or AT&T LTE networks. Sending alarm communication for burglary control panels over network or the LTE network provides higher speeds. FIELD PANEL UPDATES The Model 400 USS Flash Module allows you to conveniently field update firmware for the DualCom that would otherwise require the use of a computer and a Model 399 Programming Harness. DUALCOM PROGRAMMING DualCom programming over network or cell via Dealer Admin'" or Remote Link'" includes zone information and monitoring center communications. MULTIPLE CONNECTION OPTIONS DualCom communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer or connect the four input zones from outputs on the panel. Or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the monitoring center. FOUR ZONES Each DualCom model provides four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the app. EASY UPGRADE FOR DIALER-ONLY PANELS Older, dial-up panels have new life with the addition of network or cellular communication. Extend the life of existing customers and add modern panel features at the same time. ADD VIRTUAL KEYPAD APP Enable the Virtual Keypad app on your customers' existing panels for a minimal additional cost. Brand DMP's Virtual Keypad app with your organization's logo and contact information to provide a daily reminder of your services. DUALCOM SERIES Specifications Dimensions 5.5" W • 3.75' H • 1' D Color DualComNF Red DualComWZ White Primary Power Nominal 12 VDC or 24 VDC Current Draw at 12 VDC Standby 64mA Alarm 109mA Current Draw at 24 VDC Standby 30mA Alarm 82mA Ordering Information DualContf-LV Universal Fire Alarm Communicator with Hardwired Network Primary and LTE Backup (Verizon) Dual(ontf-LA Universal Fire Alarm Communicator with Hardwired Network Primary and LTE Backup (AT&T) DualComWHV Universal Alarm Communicator with Wi-Fi Network Primary and LTE Backup with z-wave (Verizon) DualComWZ-LA Universal Alarm Communicator with Wi-Fi Network Primary and LTE Backup with z-wave (AT&T) 685 Surface Mount Conduit Backbox Certifications Cellular FCC Part 15: XMR201707BG96 IC: 10224A-201709BG96 Underwriters Laboratories (UL) Listed DualComtf ANSI/UL 864 Fire Protective Signaling Systems (CID Capture) For additional information, go to DMP.com/Compliance. 800-641-4282 I DMP .com 2500 N. Partnership Blvd, Springfield, MO 65803 Designed, engineered & manufactured In Springfield, MO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufaclure, labeling, and packaging for a period of three (3) years from lhe Invoice date lo the original Buyer, provided that representative samples of the defective products are returned lo DMP for lnspecllon .. .To read the full DMP limited Warranty, go lo DMP.com/Warranly or check the DMP Price Lisi or Catalog. © 2019 Digital Monitoring Products, Inc. I ll-1907119132 4/19/2019 CONTROL UNIT ACCESSORIES, SYSTEM I UL Product iQ UL Product iQ™ UOXX .S3598 -CONTROL UNIT ACCESSORIES, SYSTEM Control Unit Accesso ries, System See General Information for Control Unit Accessories, System DIGIT AL MONITORING PRODUCTS INC 2500 N Partnership Blvd Springfield, MO 65803-8877 USA Investigated to UL 864 (9th edition) Alarm Router Model(s) iCOMsl Battery Model(s) 365, 366, 367, 368, 369 Battery Enclosure Model(s) 341, 349, 3525 Battery Harness Model(s) 318, 318EXT, 318R, 318T Bus Splitter Model(s) 710, 710F Control Unit Enclosure Model(s) 352P, 352X Digital Cellular Communicator Model(s) 463(, 463G Dual Line Module Model(s) 893A Enclosure Backbox Model(s) 635 End-of-Line Resistor Model(s) 310 Expansion Interface Module Model(s) 462P, 481 Expansion Module Model(s) 716, 717 Fire Control Cabinet Model(s) 348F, 350 Initiating Circuit Module Model(s) 869 Interface Module Model(s) 736P Keypad Model(s) 630F, 692F, 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173(+), 7173A, 7570, 7570A, 7573, 7573A, 790, 793 Notification Circuit Module Model(s) 865, 866, 867 Relay Modules Model(s) 860 RF Receiver Model(s) ll00XH (#) RF Repeater Model(s) ll00R Silence/Reset Switch Model(s) 303 Supplementary Signaling Module Model(s) 462N Transient Suppressor Model(s) 333 Trouble Module Model(s) 377 Wiegand Interface Model(s) 733, 734 Wireless Transmitter Model(s) 1103 (@), 1105-EOL (@) Zone Expander Model(s) 711, 7115, 714, 714-16, 714-8, 715, 715-16, 715-8, 725 https://iq.ulprospector.com/en/profile?e=152845 S3598 1/2 4/19/2019 CONTROL UNIT ACCESSORIES, SYSTEM I UL Product iQ Investigated to UL 864 (10th edition) Digital Cellular Communicator Model(s} CellComF-LTE-V%, CellComSLCF Universal Fire Alarm Communicator Model(s} DualComNF-L% # -For use with Listed DMP control panel models XRS00 and XRl00 Series. % -Suitable for use as a Primary Communicator, single communication technology. @ -For use with Listed Model ll00X and ll00XH Receivers, ll00R (Repeater}. Last Updated on 2019-04-17 The appearance of a company's name or product in this database does not in itself assure t hat products so identified have been manufactured under UL's Follow-Up Service. Only those product s bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files} must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "<O 2019 UL LLC" https://iq. ulprospector. com/en/profile?e= 152845 2/2 ier Enclosures ,inrl ( mtum {ahm .111011 Drive-Alert PRODUCTS, INC. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING · BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-2269:0536 7165--FIRE ALARM CONTROL UNIT (COMMERCIAL) Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 2 Models A007-9101 , A007-9102, A007-9201 and A007-9202 Commercial Fire Alarm Control Panels (A007-XXXX model numbers are identical to Simplex 4007-XXXX model numbers). Local, auxiliary, remote station, releasing and central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: A007-9801; Zone/Relay Module A007-9802; 25V Regulator Module A007-9803; IDNet+Loop Module A007-9804; Dual Class A Isolator Module A007-9805; 24 Zone LED Module A007-9806; SDACT Module A007-9807; City Circuit Module with Disconnect Switch A007-9808; City Circuit Module without Disconnect Switch A007-9809; Alarm Relay Module A007-9810; Flat Network Card Interface A007-9812; Dual RS232 Module A007-9813; Wired Media Module *A007-6306; ES Net NIC Dual Channel Ethernet Media Card *A007-6307; ES Net NIC Dual Channel DSL Media Car *A007-6308; ES Net NIC Dual Channel Single-mode Fiber Media Card *A007-6309; ES Net NIC Dual Channel Multi-mode Fiber Media Card *A007-9817; ES Net Network Card-Flat 4007 24 voe In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. *Revision 02-07-2019 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 NOTE: XLF: Listing No. 7165-2269:0536 Page 2 of 2 For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/ReseURestart period shall not exceed 30 seconds. Alarm Verification shall not be implemented on initiation-device circuits thaqt have the option of releasing an extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. 7165-0026:0378 ·Revision 02-07-2019 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO., M.E., F.P.E. Fire Engineering Division LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-2269:0559 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 1 Models A4606-9202, and A4606-9205 Remote LCD Color Touchscreen Annunciators. Refer to listee's data sheet for detailed product description and operational consideration. 24 Vdc In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as remote annuciators for use with listee's separately listed Series 4007ES fire alarm control units (CSFM No. 7165-2269:0536). Refer to manufacturer's Installation Manual for details. 7300-0026:0382 05-03-2018 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-2269:0558 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 1 Models A009-9601, A009-9602 and IDNAC repeaters. Model A009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. 120V/240V In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as an accessory for use with listee's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. 7300-0026:0375 05-03-2018 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-2269:0537 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01 441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 2 Models A4098-9714, A4098-9774, A4098-9754, A4098-9714BA, and A4098-9754BA analog photoelectric type smoke detectors. *Models A4098-9764, A4098-9764BA, and A4098-9764BK Multi-criteria Smoke/Heat Detectors. Models A4098-9754, A4098-9754BA, A4098-9779, *A4098-9764, *A4098-9764BA, and • A4098-9764BK analog photoelectric type smoke detectors employ an integral supplemental heat sensor (135°F fixed temperature and 20°F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating, and UL label. Listed as photoelectric smoke detectors for use with listee's separately listed compatible fire alarm control units. Units are intended for use with smoke detector bases Models A4098-9789, A4098-9791, A4098-9775, A4098-9776, A4098-9777, A4098 -9792, A4098-9793, A4098-9792BA, and A4098-9793BA (CSFM Listing No. 7300-2269:0538); 4098- -9794, -9794TSP, -9794TTP (CSFM Listing No. 7300-0026:0500). Model A4098-9714 is listed for use with Models A4098-9750 and A4098-9751 duct detector units (CSFM Listing No. 3240-2269:0539) and Model A4098-9755 duct detector unit (CSFM Listing No. 3240-2269:0526). Model A4098-971 4 with Model A4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. Refer to listee's Installation Instruction Manual for details. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more *Revision 12-16-20 WNv This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 XLF: Listing No. 7272-2269:0537 Page 2 of 2 effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 7272-0026:0218 *Revision 12-16-20 \/WW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, ME, FP.E. Fire Engineering Division LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-2269:0538 7300 •• FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 1 Models A4098-9775, A4098-9776, A4098-9777, A4098-9780, A4098-9789, A4098-9789E, A4098-9791, A4098-9792, A4098-9792E, A4098-9793, A4098-9796, A4098-9792BA, A4098-9793BA and A4098-9796BA smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Refer to listee's printed data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating, and UL label. Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Models A4098-9775, A4098-9776, A4098-9777, A4098-9780, A4098-9789, A4098-9789E, A4098-9791 , A4098-9792, A4098-9792E, A4098-9793, A4098-9792BA and A4098-9793BA are intended for use with: Models A4098-9714 and A4098-9714BA photoelectric smoke detectors (CSFM Listing No. 7272-2269:0537); and Models A4098-9733 and A4098-9733BA heat detectors (CSFM Listing No. 7270-2269:0512). Models A4098-9796 and A4098-9796BA are only intended for use with Models A4098-9754 or A4098-9754BA photoelectric smoke detector (CSFM Listing No.7272-2269:0537). These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. Refer to listee's Installation Instruction Manual for details. 7300-0026:0217 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-2269:0512 7270 -· HEAT DETECTOR Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 1 Models A4098-9733, A4098-9733E, A4098-9778, A4098-9733BA, A4098-9734, A4098-9734E, *A4098-9734BA electric combination rate compensated, fixed temperature, and rate of rise heat detector. Intended for use with listee's separately listed compatible detector bases. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 135°F and 155°F all models. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical/temperature ratings and UL label. Listed as a heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-0026:0216 *Revision 10-30-2018 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-2269:0515 Page 1 of 1 7150 --FIRE ALARM PULL BOXES Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 7;31-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Models A4099-9004, A4099-9005, A4099-9006, A4099-9015 and A4099-9021 non-coded addressable manual pull stations. Model A4099-9805 Conversion Kit. Models A4099-9004 and A4099-9021 are single action stations. Model A4099-9005 ia a breakglass station. Models A4099-9006 and A4099-9015 include a push bar which must be punched in before being able to grab and pull down the actuating handle. Model A4099-9805 is a retrofit Kit handle for field conversion of a single action station to a NO GRIP station. Refer to listee's data sheet for additional detailed product description and operational considerations. 30VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating, and UL label. Listed as manual pull stations for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. 7150-0026:0224 01-04-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,. ME., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-2269:0507 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Models A4090-9001 and A4090-9051 Supervised 1AM Monitor Module; A4090-9002 1AM Relay Module; A4090-9106 Class "A" ZAM Initiating Module and A4090-9101 Class "B" ZAM Initiating Module. Refer to listee's data sheet for additional detailed product description and operational considerations. 24 VDC 30 VDC for Models A4090-9002 series In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Autocall, model number. electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. 7300-0026:0223 01-03-18gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.PE Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7260-2269:0572 Page 1 of 1 7260 --SMOKE DETECTION SYSTEM-BEAM TYPE Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Model A4098-9019 Projected beam type smoke detector. Each unit is a transmitter/receiver, Model A4098-9020 controller and reflector prism consisting of resistors, capacitors, diodes, photo diodes, LEDs, and an LCD display mounted on a printed wiring board inside an enclosure. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 14-36VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as a projected beam type smoke detector for use with listee's Model A4010ES (CSFM No. 7165-2269:0541), A4100ES (CSFM No. 7165-2269:0542), A4007ES (CSFM No. 7165-2269:0536) fire alarm control panel. Refer to listee's Installation Instruction Manual for details. 7260-0026:0377 03-19-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INST ALLA Tl ON: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7260-1508:0104 7260 --SMOKE DETECTION SYSTEM-BEAM TYPE Page 1 of 1 FFE, Ltd.9 HUNTING GATE HITCHIN, HERTFORDSHIRE, England SG4 0TJ United Kingdom Contact: Nerina Walton +44 (0)1462 444 740 Email: nerina.walton@ffeuk.com Model Fireray 5000 Projected Beam Smoke Detector. Units consist of a controller, reflector, and a combined transmitter/receiver. Refer to listee's data sheet for detailed product description and operational considerations. 14 -*36 voe In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as projected beam smoke detection systems for use with separately listed compatible fire alarm control units. Intended for mounting to vertical wall surfaces. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. •Rev 02-02-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO., ME, F.PE Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING · BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-2269:0521 Page 1 of 1 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Model A49AV-APPLW-O Horn/strobe. Models A49AVC-WRFIRE-O, A49AVC-V\NVFIRE-O, A49AVC-WRAL T-O, *A49AVC-WNAL T-O, A49AVC-WRS-O, and A49AVC-WNS-O Horn/strobe. Model A49VO-APPLW-O Strobe. Models A49VOC-WRFIRE-O, A49VOC-V\NVFIRE-O, A49VOC-WRAL T-O, A49VOC-WNAL T-O, A49VOC-WRS-O, and A49VOC-WNS-O Strobe with suffixes . Refer to listee's data sheet for detailed product description and operational consideration. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating and UL label. Listed as signalling devices for the hearing impaired. Refer to listee's Installation Instruction Manual for details. 7125-0026:0371 *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-2269:0520 7125 •• FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Tyco Fire & Security GmbH6 Technology Park Drive, Westford, MA 01886 Contact: Sonya L'ltalien (978) 577-4074 Fax (978) 731-8881 Email: sonya.litalien@jci.com Page 1 of 2 Model A49MTV-APPLW True Alert ES Addressable Horn/Strobe. Model A49CMTV-APPLW True Alert ES Non-Addressable Horn/Strobe. Models A49SV-APPLW-O, A49SV-APPLW-O-BA Wall Mounted Horn/Strobes. Models A49AO-APPLC-O, A49AO-APPLC-O-BA, A49AVH-APPLC-O, A49AVH-APPLC-O-BA, A49AVH-APPLC-CO, A49VOH-APPLC-O, A49VOH-APPLC-O-BA, and A49VOH-APPLC-CO True Alert ES Addressable Horn/Strobes. Models A49VO-APPLC, A49VO-APPLC-BA, A49VOH-APPLCA, A49VOH-APPLCA-BA, A49VOH-APPLCB, A49VOH-APPLCB-BA, A49VOH-APPLC, A49VOH-APPLC-BA, A49VOC-CRAL T, A49VOC-CRBF,A49VOC-CRFEU, A49VOC-CRF, A49VOC-CRS, A49VOC-CWAL T, A49VOC-CWBF, A49VOC-CWFEU, A49VOC-CWF, A49VOC-CWS, A49VOC-CK, A49VOC-CRBAF, A49VOC-CRBCF, A49VOC-CWBAF, A49VOC-CWBCF, A49VOC-CRBAA, A49VOC-CWBAA, A49VO-APCS, A49AV-APPLC, A49AV-APPLC-BA, A49AVH-APPLC, A49AVH-APPLC-BA, A49AVH-APPLCA, A49AVH-APPLCA-BA, A49AVH-APPLCB, A49AVH-APPLCB-BA, A49AO-APPLC, A49AO-APPLC-BA, A49AVC-CRAL T, A49AVC-CRBF, A49AVC-CRFEU, A49AVC-CRFIRE, A49AVC-CRS, A49AVC-CWAL T, A49AVC-CWBF, A49AVC-CWFEU, A49AVC-CWFIRE, A49AVC-CWS, A49AVC-CK, A49AVC-CRBAF, A49AVC-CWCAL T, A49AVC-CWBAF, A49AVC-CRBAA, A49AVC-CWBAA, A49AOC-CRAL T, A49AOC-CRBF, A49AOC-CRFEU, A49AOC-CRFIRE, A49AOC-CRS, A49AOC-CWAL T, A49AOC-CWBF, A49AOC-CWFEU, A49AOC-CWFIRE, A49AOC-CWS, A49AOC-CK, A49AOC-CRBAF, A49AOC-CWCAL T, A49AOC-CWBAF, A49AOC-CRBAA, A49AOC-CWBAA, A49AV-APPLW-O-BA, A49VO-APPLW-O-BA, and *A49VO-APPLW. *Revision 6-1-21 VVVW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO,, M.E., FP.E Fire Engineering Division Listing Expires June 30, 2022 RATING: INSTALLATION: MARKING: APPROVAL: XLF: Listing No. 7125-2269:0520 Page 2 of 2 Refer to listee's data sheet for additional detailed product description and operational considerations. Voltage: 16-33 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical/candela rating, and UL label. Listed as horn/strobes when used with separately listed electrically compatible fire alarm control units. Units are approved for indoor and suitable for wall or ceiling mounts. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. 7125-0026: 0380 •Revision 6-1-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO,, M.E., F.PE Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING : APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-2269:0534 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Model A49AVTrue Alert ES addressable horn/strobes with suffix APPLW. Page 1 of 1 Model A49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, WWFIRE, WRS, WWS, WRAL T, WWAL T, and *WWBLNG. Refer to listee's data sheet for detailed product description and operational consideration. 17-31 Vdc In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating, and UL label. Listed as a wall mount horn/strobe for indoor use only. Models require the use of Autocall A007-9201 and A007-9202 Control Units (CSFM No. 7165-2269:0536). Refer to listee's Installation Instruction Manual for details. 7125-0026:0373 *Revision 3-11-21 VVWV This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO., M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-2269:0520 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Tyco Fire & Security GrnbH6 Technology Park Drive, Westford. MA 01886 Contact: Sonya L'ltalien (978) 577-4074 Fax (978) 731-8881 Email: sonya.litalien@jci.com Page 1 of 2 Model A49MTV-APPLW True Alert ES Addressable Horn/Strobe. Model A49CMTV-APPLW True Alert ES Non-Addressable Horn/Strobe. Models A49SV-APPLW-O, A49SV-APPLW-O-BA Wall Mounted Horn/Strobes. Models A49AO-APPLC-O, A49AO-APPLC-O-BA, A49AVH-APPLC-O, A49AVH-APPLC-O-BA, A49AVH-APPLC-CO, A49VOH-APPLC-O, A49VOH-APPLC-O-BA, and A49VOH-APPLC-CO True Alert ES Addressable Horn/Strobes. Models A49VO-APPLC, A49VO-APPLC-BA, A49VOH-APPLCA, A49VOH-APPLCA-BA, A49VOH-APPLCB, A49VOH-APPLCB-BA, A49VOH-APPLC, A49VOH-APPLC-BA, A49VOC-CRAL T, A49VOC-CRBF,A49VOC-CRFEU, A49VOC-CRF, A49VOC-CRS, A49VOC-CWAL T, A49VOC-CWBF, A49VOC-CWFEU, A49VOC-CWF, A49VOC-CWS, A49VOC-CK, A49VOC-CRBAF, A49VOC-CRBCF, A49VOC-CWBAF, A49VOC-CWBCF, A49VOC-CRBAA, A49VOC-CWBAA, A49VO-APCS, A49AV-APPLC, A49AV-APPLC-BA, A49AVH-APPLC, A49AVH-APPLC-BA, A49AVH-APPLCA, A49AVH-APPLCA-BA, A49AVH-APPLCB, A49AVH-APPLCB-BA, A49AO-APPLC, A49AO-APPLC-BA, A49AVC-CRAL T, A49AVC-CRBF, A49AVC-CRFEU, A49AVC-CRFIRE, A49AVC-CRS, A49AVC-CWALT, A49AVC-CWBF, A49AVC-CWFEU, A49AVC-CWFIRE, A49AVC-CWS, A49AVC-CK, A49AVC-CRBAF, A49AVC-CWCALT, A49AVC-CWBAF, A49AVC-CRBAA, A49AVC-CWBAA, A49AOC-CRAL T, A49AOC-CRBF, A49AOC-CRFEU, A49AOC-CRFIRE, A49AOC-CRS, A49AOC-CWAL T, A49AOC-CWBF, A49AOC-CWFEU, A49AOC-CWFIRE, A49AOC-CWS, A49AOC-CK, A49AOC-CRBAF, A49AOC-CWCAL T, A49AOC-CWBAF, A49AOC-CRBAA, A49AOC-CWBAA, A49AV-APPLW-O-BA, A49VO-APPLW-O-BA, and *A49VO-APPLW *Revision 6-1-21 VWIN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operatio_nal requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 RATING: INSTALLATION: MARKING: APPROVAL: XLF: Listing No. 7125-2269:0520 Page 2 of 2 Refer to listee's data sheet for additional detailed product description and operational considerations. Voltage: 16-33 voe In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Autocall, model number, electrical/candela rating, and UL label. Listed as horn/strobes when used with separately listed electrically compatible fire alarm control units. Units are approved for indoor and suitable for wall or ceiling mounts. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. 7125-0026:0380 •Revision 6-1-21 1/1/W,/ This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,. M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1157:0136 7300 -· FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (41 7) 447-9698 Email: abade@dmp.com Page 1 of 1 Models CellComSLC, CellComSLCZ, CellComSLCF, CellCom-L TE-V, CellComZ-LTE-V, CellComF-L TE-V, iComSLF, iCOMSL, iComSLZ, DualComNF-L, *CellComSF, and *CellComDF Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. 12 voe or 24 voe In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Revision 02-26-20 1/W,/V This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-2269:0536 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) Tyco Fire & Security GmbH50 Technology Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Page 1 of 2 Models A007-9101, A007-9102, A007-9201 and A007-9202 Commercial Fire Alarm Control Panels (A007-XXXX model numbers are identical to Simplex 4007-XXXX model numbers). Local, auxiliary, remote station, releasing and central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: A007-9801; Zone/Relay Module A007-9802; 25V Regulator Module A007-9803; IDNet+Loop Module A007-9804; Dual Class A Isolator Module A007-9805; 24 Zone LED Module A007-9806; SDACT Module A007-9807; City Circuit Module with Disconnect Switch A007-9808; City Circuit Module without Disconnect Switch A007-9809; Alarm Relay Module A007-9810; Flat Network Card Interface A007-9812; Dual RS232 Module A007-9813; Wired Media Module *A007-6306; ES Net NIC Dual Channel Ethernet Media Card *A007-6307; ES Net NIC Dual Channel DSL Media Car *A007-6308; ES Net NIC Dual Channel Single-mode Fiber Media Card *A007-6309; ES Net NIC Dual Channel Multi-mode Fiber Media Card *A007-9817; ES Net Network Card-Flat4007 24 VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Autocall, model number, electrical rating and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. *Revision 02-07-2019 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01 , 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 NOTE: XLF: Listing No. 7165-2269:0536 Page 2 of 2 For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/ReseURestart period shall not exceed 30 seconds. Alarm Verification shall not be implemented on initiation-device circuits thaqt have the option of releasing an extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. 7165-0026:0378 •Revision 02-07-2019 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01 , 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, ME., F.PE Fire Engineering Division