Loading...
HomeMy WebLinkAbout1800 ASTON AV; 200; FPC2018-0393; PermitPERMIT REPORT (èityof Carlsbad Fire Sprinklers Print Date: 02/11/2021 Job Address: 1800 ASTON AVE, # 200, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Clas: Parcel #: 2121206100 Track #: Valuation: $1,038,893.87 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0393 Status: Closed - Finaled Applied: 12/05/2018 Issued: 12/19/2018 Finaled Close Out: 08/14/2019 Inspector: Final Inspection: Project Title: Description: ARROWHEAD INSURANCE - RELOCATE/ADD NEW PENDENT (97 HEADS) SPRINKLER PROTECTION FOR NEW SUSPENDED CEILII' Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 • • • (760) 295-3436 (760) 295-3436 • • FEE AMOUNT FIRE NFPA 13 or.13R System 7 - 100 heads • • • $553.00 Total Fees: $553.60 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department • Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 1 760-602-8561 f I www.carlsbadca:gov - -v 1 (1 1TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18737 Arrowhead Insurance 1800 Aston Ave., Suite 200 Carlsbad, CA 92008 Sizes: 2 1/2", " 4", " " I MODEL Maximum working water pressure 175 PSI 350ASTDA Maximum working water temperature 140°F with Hydrostatic test pressure 350 PSI OS&Y option End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) WEIGHT MODEL I wim i wim35OASTDA OS&Y OS&YBUTTERFLY I BUTTERFLYSIZE GATES (GXF) GATES (GXG) vAvss (GXG) I vu.vs (FXG) In. I mm lbs. I ka I lbs. I ka tbs. I ka I tbs. I ka I D1 :) ZURN Model 350ASTDA EXISTING WILKINS Double Check Detector Assembly Application Designed for installation on water tines in fire protection systems to protect against both backsiphonage and back- pressure of polluted water into the potable water supply. Model 350ASTDA shall provide protection where a potential - health hazard does not exist. Incorporates metered by-pass - to detect leaks and unauthorized water use. it NSFIANSISI Standards Compliance (Horizontal & Vertical) ASSES Listed 1048 AWWA Compliant C510 (with gates only) and C550 UL® Classified C-UL® Classified FM® Approved CSA® Certified B64.5 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI 61 (0.250/. MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4" Model 950XLD Materials Main valve body 304L Stainless steel Access covers 304L Stainless steel Internals Stainless steel, 300 Series NORYLTm Fasteners & springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYL" Features (SHOWN WTH OPTIONAL FLANGED END BUTTERFLY VALVES) Options (Suffixes can be combined) - with flanged end OS & V gate valves (standard) LM - less water meter - with remote reading meter - with gallon meter (standard) CFM - with cu it meter CMM - with cu meter meter 6 - with grooved end OS&Y gate valves FG - with flanged inlet gate connection and grooved outlet gate connection P1 - with Post Indicator Gate Valves BG - with grooved end butterfly valves with integral supervisory switches BF - with flanged end butterfly valves with integral supervisory switches —509 - with AWWA C509 gate valves RV - with By-pass on right hand side Accessories Repair kit (rubber only) O Thermal expansion tank (Model XI) OS & Y Gate valve tamper switch (OSY-40) Zum Industries, LLC I Wilkins Rev. M 1747 Commerce Way, Paso Robles, cAu.s.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 6/17 In Canada I Zurn Industries Limited Document No. BF-350ASTDA 3544 Nashua Drive, Mississauga, Ontario L4V 112 Ph. 905-405-8272, Fax 905-405-1292 Product No. Model 350ASTDA www.zurn.com I Page l of 2 Flow Chratènstics 50.5 —1104 as - 0. s) . - U) : : 800 252.4 138 0. 104 cn 10" U) to 0 -j 10 0 1000 2000 3000 FLOW RATE (GPM) o Rated Flow (established by approval agencies) Pa MODEL 350ASTDA2 1/2",3" & 4" (STANDARD & METRIC) FLOW RATES (Us) 12.6 25.2 37.9 0 200 400 600 FLOW RATES (GPM) MODEL 350ASTDA6" 8" & 10" (STANDARD AND METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 20 a U) .15 —I 69 w 35 LU —I U) —I E —1 - 0 4000 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. ZURN WILKINS MODEL 350ASTDABG INDOOR VERTICAL INSTALLATION Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/211 75 112 149 224 3° 115 173 230 346 4" 198 298 397 595 60 450 675 900 1351 8° 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 PROTECTIVE ENCLOSURE 12" MIN. 30" MAX DIRECTION OF FLOW ZURN WILKINS MODEL 350ASTDA OUTDOOR HORIZONTAL INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and sup- plied with full port gate valves. The main body and access cover shall be 304L Stainless Steel, the seat ring and check valve shall be Noryl'TM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detec- tor Backflow Prevention Assembly shall be a ZURN WILKINS Model 350ASTDA. Zurn IndustrIes, LLC I Wilkins 1747 Commerce Way, Paso Robtes, CA U.S.A. 93446 Ph. 855.663.9876, Fax 805-238-5766 In Canada I Zum Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 U Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 V3801 and V3802 FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Technical Specifications: Standard and Quick Response Models: V3801, V3802 AC_ta uI i c 40.50 Approvals/Listings: LISTED 0832 104-ia/02 © See Victaulic Publication 10.01 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2713 mm adjustment to accommodate concealment needs. The "standard" design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: 1/2713 mm K-Factor: 5.6 Imp./8.1 S.l.' Nominal Thread Size: 1/2715 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 updated 07/2014 0 2014 Victaulic company. All rights reserved. 1 JAi C_ tauIicr victaulic.com I Sprinkler I Firel-ockO I K5.6, V38 I Publication 40.50 Material Specifications: Accessories: Deflector: Bronze per UNS C22000 Installation Wrench: Cover Plate: Fusible solder 0 Concealed: V38-4 or V38-5 Bulb: Glass with glycerin solution. Sprinkler Finishes: O Plain Brass (only) Bulb Nominal Diameter: El Standard: 5,0 mm Cove! Finishes: o Quick Response: 3,0 mm 0 Chrome Plated O White Painted3 Load Screw: Bronze per UNS C65100 El Flat Black Painted3 Pip Cap: Bronze per UNS C65100 0 Custom Painted3 Spring: Stainless steel per UNS S30100 2 Teflon is a registered trademark of Dupont co. UL listed for corrosion resistance. Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene 11 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic company. All rights reserved. tii.uIicr victaulic.com 2 victaulic.com I Sprinkler I FireLocke I K5.6, V38 I •Publication 40.50 Approval/Listings: Approvals/Listings Model V3801 V3802 Orifice Size (inches) '/2" 'Is" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor S.0 8.1 8.1 Response Standard 5mm bulb Quick4 3mm bulb Deflectorlype Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings P/C" V3801 V3802 135F/57C 135F/57C 155F/68C 155F/68C cULus 175 F/79 C 175 Ff79 C 200 F/93 C 200 F/93 C 155 F/68 C4 FM5 NONE 175 Ff79 C4 200 F/93 C4 135 F/57 C 135 F/57 C NYC/MEA5 #62-99-E i55F/68C 155F/68C 175F/79C 175F/79C 200 F/93 C 200 F/93 C 135 F/57 C 135 F/57 C CSFM5 #7690-0531:112 155 F/68 C 155 F/68 C 175 Ff79 C 175 Ff79 C 200 Ff93 C 200 F/93 C 155°F/68"C Sprinkler/1 38°F/59"C Cover 155"F/68°C Sprinkler/1 38°F/59°C Cover LPCB 175°F179"C Sprinkler/1 65°F174°C Cover 175"Ff79°C Sprinkler/1 65°F/74°C Cover 200"F/93°C Sprinkler/1 65"F/74"C Cover 200°F/93°C Sprinkler/1 65°F174"C Cover 135 F/57 C 135 F/57 C 155F/68C 155F/68C VNIIPO 175 F179 C 175 F179 C 200 F/93 C 200 F/93 C 286 F/141 C . 286 F/141 C CCCI ZSTDY NONE 155 F/68 C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 Updated 07/2014 @2014 Victaulic Company. All rights reserved. victaulic.com 3 _jtauIic" victaulic.com I Sprinkler I FireLock I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 2%'/68 mm Max. He 2M?/6O mm MiitHole 2 /59mm I mm Typical Ceiling Tile FinIshed Surface Minimum Extension 2%'fll mm W/13 mm Adjustment 3W/SO mm 3W/83 mm Cover Plate Maximum Extension 2'/Sl mm Typical Ceiling lila - Finished Surface Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory 0 U.I uii.a.aai1 IIIIUIIIIII: UIIIIUIU IIIII%IIIIIU 1111111 UI.. mmmmmmmm -I...IIII1'i-I MM IIIIIIIIIIkI IIIIIIIIIIR 2' 4' 6' B. 10' 12' 14' 0.6m 1.2m 1.8m 2Am 3.0m 3.7.m 43m 7ps1 _.._.. 15 psi 30 psi 48kPa 103kPa 207kPa 10' - 3.Om 8' 2.4 m 6 Ism 4' 1.2m 2' 0.6 m NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 4 j4tauiic victaulic.com I Sprinkler I FireLockO I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -670 FI-550C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature— F/C Temperature— F/C Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135 Ff57 C 1 100 F/38 C Orange A' 1 1356 57 100 57 Ordinary C 155 F/68 C 100 F/38 C Red D7 17645 150 65 Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F1141 C 225 Ff107 C Blue Extra High a K 360 Ff182 C 300 F/149 C Purple - M Open - No Bulb 'A For use with Standard or Quick Response concealed Sprinkler 135F/57C or 155F/68C. 'D For use with Standard or Quick Response Concealed Sprinkler 175°F179°C or 200°F/93°C. 8 138°F159°C per LPCB Note: Custom Finish - Customer to provide paint specification, allow 4 - 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent —V3801,V3802 V38-4 orV38-5 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic Company. All rights reserved. tauIic victaulic.com 5 victaulic.com I Sprinkler I FireLocke I', K5.6, V38 I Publication 40.50 Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Ls 7 0 M Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in POE format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 \Jl'ctauljc FireLock® V27, K5.6 lictaullicr Models V2703, V2707, V2704, V2708 40.10 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½/13 mm K Factor: 5.6 Imp./8.1 S.1.1 Nominal Thread Size: ½" N P1/15 mm V2703/V2704 V2707N2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for mare details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /41/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLockO I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. jtauIic 1 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Installation Wrench: LI Open End: V27 LI Recessed: V27-2 Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White painted3 LI Black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LI VC-2504 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. Bulb: Glass with glycerin solution Bulb Nominal Diameter: fl Standard: 5.0 mm LII Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 -11,, A—C—taulicy victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model _ _____ APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2' 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F'/C' 135'F/57'C 135'F/57°C 135°F/57'C 135'F/57'C 135'F/57'C 155'F/68'C 155°F/68"C 155°F/68°C 155"F/68'C 155'F/68'C cULus 175°F/79"C 175'F/79'C 175"F/79°C 175°F/79'C 175°F/79'C 200°F/93'C 200'F/93°C 200°F/93'C 200°F/93'C 200°F/93'C 286'F/141'C 286°F/141'C 286'F/141'C 286'F/141'C 286°F/141'C 360°F/182'C 360°F/1 82'C 135°F/57'C 135°F/57'C 135°F/57°C 135'F/57"C 155'F/68°C 155'F/68'C 135°F/57'C 155°F/68°C 155'F/68'C FM 175'F/79°C 175°F/79°C 155'F/68'C 175'F/79°C 175°F/79°C 200°F/93'C 200'F/93'C 175°F/79'C 200°F/93'C 200°F/93'C 286'F/141'C 286'F/141"C 200"F/93°C 286'F/141'C 286'F/141'C 360'F/182°C 360'F/182'C 135'F/57'C 135°F/57°C 135°F/57'C 135'F/57°C 135°F/57'C 155°F/68'C 155'F/68'C 155'F/68'C 155°F/68'C 155'F/68'C NYC/MEA 62-99-E 175'F/79'C 175'F/79'C 175°F/79'C 175'F/79'C 175°F/79°C 200'F/93°C 200'F/93°C 200°F/93"C 200"F/93'C 200'F/93'C 286°F/141'C 286°F/141°C 286'F/141'C 286°F/141'C 286°F/141°C 360'F/1 82'C 360°F/182°C 135'F/57°C 135°F/57°C 135°F/57'C 135'F/57'C 135'F/57°C 155'F/68"C 155°F/68'C 155°F/68°C 155'F/68°C 155°F/68'C CSFM 7690-0531:112 175°F/79°C 175°F/79'C 175'F/79°C 175°F/79'C 175'F/79'C 200°F/93'C 200°F/93'C 200'F/93'C 200'F/93'C 200'F/93'C 286"F/141'C 286'F/141'C 360'F/1 82'C 286°F/141°C 286°F/141'C 286°F/141°C 360'F/182°C 135°F/57'C 155'F/68°C 135'F/57'C LPCB 175°F/79'C None None 155'F/68'C None None 2b0'F/93'C 175'F/79'C 286°F/141'C 200°F/93'C 360°F/1 82'C 135'F/57'C 135'F/57'C 135'F/57'C 135'F/57'C 155'F/68°C 155'F/68'C 135°F/57'C 155'F/68'C 155°F/68'C VNIIPO 175'F/79'C 175'F/79'C 155°F/68'C 175'F/79'C 175°F/79'C 200°F/93'C 200'F/93'C 175°F/79'C 200°F/93'C 200'F/93°C 286'F/141°C 286'F/141'C 200'F/93'C 286°F/141'C. 286°F/141'C 360°F/182'C 360'F/182'C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155'F/68'C 155°F/68'C None 155F/68'C 155°F/68'C None 200'F/93'C 200'F/93°C 200'F/93'C 200°F/93'C 135°F/57'C 155'F/68°C 155'F/68°C VdS 175'F/79'C None None 175'F/79'C None None 200'F/93°C 200'F/93'C 286'F/141'C 286°F/141°C 360°F/1 82'C 135°F/57'C 135'F/57'C 155'F/68°C 155'F/68'C CE 175'F/79'C None None 175'F/79'C None None 200'F/93'C 200°F/93'C 286'F/141°C 286'F/141'C 360°F/1 82'C 5 For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2' adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 stauIicr victaulic.com I Sprinklers I FireLo&® I K5.6, V27 I Publication 40.10 Dimensions: 17A6"/ A I 37 mm 2 60 1W/ 2W/ 41 mm 60 mm Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2/51 mm Mm. Hole jrr l4e/ Typical Ceiling rile J -Finished Surface 30 m MAXIMUM RECESS 21W? 75 mm MAXIMUM EXTENSION W Adjustment Recessed - V2707, V2708 (drawing not to scale) MaxHole 2/51 mm Mm. Hole ,c37tmtm Typical Ceiling Tile 24 mm Finished Surface MAXIMUM RECESS - 75 mm MAXIMUM EXTENSION -V4 Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. \/1tauIic.' victaulic.com 4 17 mm 43 24 mm victaulic.com I Sprinklers I FireLock® IK5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent uissrioution tauerns - u rajectory "IN 11 t% 2' Ir 6' 8' 10 12' IN 0Am 1.2m lAm 2Am agm 3.7m 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory mmmmmmmmmmmmi iuuuiva•uui• m•uu•muiu•u iuuiuusisuu• mmmmmmmmm . uauii•iuuuiuu 2' 4' I6' 6' 10' 12' 14 16' 04,111.2m ism 2Am 34,g 33,11 4.3m 4 S NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Ustings, Approvals and Warranties, All patterns are symmetrical to the centerline of the waterway. - - 40.10 2544 Rev. J Updated 07/2014 @2014 Victaulic Company. All rights reserved. victaulic,com 5 XOA-C—ta—ulicr 0. IV 6' 2Am 6' lAm 4. 1.2m 2' GAM 0 7p5I 48 kPa 15 psI 103 kPa 30 psi 207 kPa 7p51 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 Ff38 C Orange Ordinary C 155 F/68 C 100 Ff38 C Red Intermediate E 175 F/79 C 150 Ff65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8f107 C Blue Extra High 7 K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. 8150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703,V2704 upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. N__ ME Installation Note Reference should always be made to the 1-40 Victaulic fireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be Installed In accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available In POF format on our webslte at victautc.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. .1 Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 6 XoAcna _U1 I Cr Bull Moose TOW Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube" made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube'sR Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®ijs LISTED (;]4 owa NFPA es=- 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR WEIGHTIFT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 i1/4 'TILIJTI1 1TI TI LJTI II 5ITIT TII 1 .682 2.O9Ibs/ft 3:053 61 II 2TI 2157 627 )ibJ[ I 21/2 2875 2635 492 L 353Ibs/ft 5893 - 30 S00 9IL! 7!!1JL i 4 4500 4.260 -- 250 [ 562 lbs/ft 11796 1911 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR WEIGHTIFT WEIGHT SIZE 1.315 1.049 100 i68th 2.055 L 20 I IL L 75 2.468 L L 875 L IITIEIiEiiIIITIL_758 lbs/ft ir i1TIi! TIl 4* 4500 i 4026 [ 100 lO8Olbslft 16316 19 Only available in Casa G,andAZ 'carronion Resistance Ratio per latest UL DlznctaryUsting PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembI causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com QN2 1819 Claskson Road C1ttetfieIMO GeralctMo Kent WA Casa GcendAZ Da1l1X MasunOH 63017 Dull Moose Tube's Eddythread 40 ADVANTAGES OF BULL MOOSE TUBES EDDVTHREAD 40 I) is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM A135 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threaclability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 119 MIC preventative coating. EDDVTHREAD 40 SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LBIFT WEIGHT SIZE 'Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. (;] 4Qf NFPA — ( For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 8824666 saIes@bullmoosetube.com 1819 Clailcson Road thesteefiektMo Gera?d.MO Kent WA CasaGTand6AZ Dalia1X MasenOH 63017 5 Bull Moose Tube's0 Eddylite0 is a lightwall threadable pipe manufactured in NPS 1 through 2. EddyliteO is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite0 is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED (;] 4QA NFPA' '.-'--- 6 ADVANTAGES OF BULL MOOSE TUBE° EDDVLITE° 'Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other Iightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings fittings, and valves. 'Freight savings. 'Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. 'Wall thickness and weight close to Schedule 30; compare to other Iightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1.315 1.137 1 0.13 7.47 111.260 0 1.700 91 61 conoion Resistance Ratio per latest UL Directoly Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( 0 For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkoan Road Otesteifield,MO Gerald. MO Knt.WA CasaGrandgAZ Dallat,IX MassntOH 63017 - - c®us LISTED (i;] NFPA ADVANTAGES OF BULL MOOSE TUBE' EDDY FLOW' Certified to ASTM A135 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. 'Can be supplied roll grooved or plain end. 'Can be hot dipped galvanized to meet FM'S & UL requirement for dry systems. 'Supplied with EDDY GUARD II' MlC preventative coating. NPS O.D. EDDY FLOW' EDDY FLOW' WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR' PER Ft WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 _iiiL1i i.728 44 L1 2 2375 2203 278 2330 3982 fl 1 2875 Ô5][ 166 3[ 280 5299 3 3500 3.334 [100 31.361 JL 7144 ] 141E 4.500 ][ 4.310 19 1 19] Corrotion Retistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Cladcson Road ChoaterfitittMO GetaktMO Kent WA CasaGrandAZ DaiaOX Masu,OH 63017 7 Bull Moose Tube's' Eddy Flow' is a specially engineered replacement for Schedule 10. offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore. Eddy Flow's' larger ID provides an opportunity for downsizing and further cost savings. Dull Moose Tube'se Ultra Eddy is ADVANTAGES OF BULL MOOSE TUBE° ULTRA EOOV I) a versatile product that can be • Certified to ASTM A135 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today. Ultra Eddy offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY6 WEIGHT WATER BUNDLE (IN) (IN) EDDY9ID) CRR** PER FT. FILLED WT. SIZE 1 1.31S 1.201 2.17 868 1.359 91 1.786 1.11 Pressfit is Registered Trademark of Victaulic cernpany of kneilca ••Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED NFPA •.=— 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( F For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clailcson Road 0tRSterfIRIMO GecaktMo kesitWA Casa GrandAZ Dallat,1X Masuitt0H 63017 NPS (IN) 1 1-114 1-112 2 2-112 3 4 D. (in) 1.315 1.660l1.9002.375 1201 1546 IF 1786 2261 ULTRA EDDYO 0868 1107 1.214 1604 1359 1920 2360 3344 C.R.R.217 r 140 r 111 100 ÜD.6n) in 1n10-1r-i7guflr7r81 EDDY FLOW jWMu-RHedWek "-' ___------- jht _OW,[iUj[ 2860 1L 3982 1Li!!!i1L1!1flP9° r°°ii1L°o L o.o6n ]c 1315 r 1660 1900 I 2375 2875 3500 4.500 i acm) 1 1097 1 442 1 682 2 157 2 635 3260 4260 SCHEDULE 1 410 1 810 2.090 2 640 3530 4340 5.610 0 LWatufilledftoMf1820 2518 3053 4223 893 795 11796 627 412 354 250 ___ j[1900j 3 1[Ii iLlil iTiWIIITh37 !_iLii L 1I771LI Iii1Ii[ EDDYUTE _ iiiiiiiEi1[ 1.260 1.617 1r67 c®us LISTED ARDS ] AfSA NFP o1rT:9rL 2375 IL THr EDDYTHREAD r LD.O__I1t083 40 [Iiii1 1.461 1 2.070 2.547 3308 1.8607 2.7S43.468 :oo s: ::oo too 1315 1.660j[ 1.900 ] 3.50QJ On)_ TÔ4 1380 2067 2.469 30681 4026 ght SCHEDULE iao TÔII Tj 3660 5.800 7580 J 10800 osX r6o1L4i1El8i ]riO28ii]r 16316] _____ ci 1111] [ThoI11] r 1:11 ir _1L_iITIIi1i LIo1j 0 For Additional Information Contact (800) 325-4467 wwwbutlmoosetube.com Qib - Or From Canada Call: (800) 882-4666 sales@builmoosetube.com 1819 tlarkson Road Oiesxe,fmktMo Gera4M0 KentWA CasaGiande.AZ DaIla1X Masin0H 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRAEDDY'0.868 91 H 1,659 HL 1.896 1.975 SCHEDULE1O 1410 91 2695 t 3,079 3,208 1 1260 91 2,408 2,752 2,867 rEDDYTHREAD 40' ] 1 461 70 2.148 2454 1 2,557 1.00, 70 2,470 2822 2.940 1222 ][T688 j 1114 61 !41 °II iLi2 _________ SCHEDULE 40 2270 ir243f L 778 ir T894 !DDYJ 1 274 61 632 1 865 1,943 EDDY LOIT 1844 61 2362 1 2700 2812 [çpflJ 2.090 61 2677 3060 3187 1112 [JDDYLITE' j 1.967 61 2,526 2880 1,066 EDDYTHREAD4O' 1 2547 1 44 - 23 2690 2802 [::DULE40 2720 { 44 2,513 2872 2992 I ULTRA EDDY' 1ri ir 1.4241r1.4841 2 EDDYUTE' 26 37 _lo!! p2324 2.421 EDDYTHREAD4O 3308 30 2084 $2382 T48f SCHEDULE4O 3660 2809 3530 5800 30 2,306 2635 2745 1 770 2022 Z167 30 2224 2542 2,648 3654 4176 4350 2112 I EDDY FLOW' -SCHED[IIIULE1III]r SCHEDULE40 I 1 3 LciDui'JL_ AM _JJ 19 1u4oLi=7580 iijL - I4 36q J L EDDY FLOW' j 4.968 1 ,982 2,265 2,36O 4 I ScHEDUi1 5620 19 L 2242 [ - 2,563 - 2,670 LjiD L ]L L .130 6 i OnlyAvailable In Casa Gtande.AL c®us LISTED GO 4f1A NFPA' 10 Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading. Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE-O5 ) & Ci' for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. F25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 1 3.00 1114 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 1 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 12351 1012 8671 726 40 40 40 1 40 1 40 1 37 1 34 1 32 30 29 28 26 Bull Moose Tube EDDYThREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCEO ) & Ci' for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. r25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 1 0.75 1.00 1.25 1.60 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL. MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED (;] AQA NFPA ( For Additional Information Contact (800)325-4467 www.butImoosetube.com Or From Canada Call: (800) 8824666 sales@bullmoosetube.com 1819 Clarkson Road OteIfekLMO Gets?d.MO KoaWA CaGTandAZ 0aIlTX MasuiOH 63017 11 MechanicaIT® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a hoIefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connktions can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/345OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to .i-230°F/-340C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +1800F/-290C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140017/+600C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOBIOWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect___________ Para_________ Location Date Approved Date_________________________________ www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTALILIC COMPANY. C 2017 vlclAuuc COMPANY. ALL RIGHTS RESERVED. REV_N jtaUIicr 11.02_i STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1050 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets Size No. l,essu,e@ Dimensions Weight Each 98 L t8i • q 2 ½ (a) U 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 - 41 136 70 1.5 - !A (a) 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) a 920 N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 - 41 136 70 1.4 - 114 (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 443 52 70 76 41 136 76 1.7 1.5 1 (a) to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 - 41 136 83 1 1.7 1.5 2½ ½ (a) " X 92 ON 500 150 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - 920N 500 150 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55. 70 - 46 143 70 1.4 - 1 (a) In 920W 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 1 143 70 1.4 - I'A 1(a) a 920 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 445 58 76 83 46 160 76 1.7 15 1½ 1(a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½(a) 76.1 x 920 N 300 150 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 1 57 164 81 1.8 - 'A (a) 920 N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 1 164 81 1.8 1 - 1(a) 920N 300 130 2.07 2.75 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 70 - 57 164 81 17 1¼ 0) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 443 58 76 84 49 160 76 1.6 1S 1½ (a) a 0 92 ON 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 ½ (a) a 92ON 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 3450 38.1 64 78 - 58 156 70 1.6 - `14 (a) a 920 N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 1¼ (a) fa 920N 500 1.75 255 3.25 356 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1½ (a) to 920W 500 2.00 2.78 3.50 336 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a) a 920N 500 2.50 2.75 3.50 336 2.28 6.75 3.88 4.9 4.6 50 3450 635 70 89 90 58 172 99 2.3 2.1 3½ 2 x 920N 500 250 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 635 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet Is available as listed. Specify 'BSPr clearly on order. (b)For 76.1 mm threaded outlet, specify 2W BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaullC.com /.tIEl.0 11cr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 vICTAUuc COMPANY. ALL RIGHTS RESERVED. 11.02_2 REV_N DIMENSIONS It-@ 14", A JWJ GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa .on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 41200 x 100mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Dimensions Weight Each Oir12 (3Ll tnfl 8it4k erza. 888ii 8at4it .L Sil ilb I1I it iI) - - alp am TABLE CONTINUED FROM PAGE 2 4 ½ (a) a 920N 500 1.50 3.03 3.56 ' 2.69 7.01 2.75 3.7 100 15 3450 38.1 77 90 - 68 178 70 1.8 - 7(-)'920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 1(a) a 500 920N 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1 ¼ (a) to 920 N 500 32(b) 3450 443 78 96 102 68 178 76 1.9 1.8 1 ½ (a) to 920 N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to 920 N 500 250 3.25 4.00 4.00 2.69 7.Ol 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178' 99 2.3 2.1 21h (a) t 920 500 2.75 2.88 4.00 4.00 2.69 734 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 3(a) t 2 9 0 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1¼ (a)a 108.0 x 20N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 445 78 96 - 67 194 78 2.3 - 1 ½ (ala 20N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 2.3 - 2 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 635 83 102 67 194 102 1.9 - 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8. 7.8 3450 69.9 73 102 102 67 194 109 3.6 35 3(a) 20 500 3.50 3.31 450 4.50 2.63 7.63 4.88 6.8 65 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1 ½ (a) t 9 0 2 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) t 920 500 - 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 216 (a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm 920 2 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 3(a) f 2 9 0 500 350 3.81 5.00 9.70 531 8.4 8.8 80 3450 88.9 97 127 118 246 135 3.8 4.0 2 920 N 500 2.50 3.75 430 4.63r 3.00 8.00 3.88 8.0 133.0 x 50 3450 63.5 95 114 -203 99 3.6 - 3 920 500 3.50 3.81 5.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 240 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ' Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be f Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21& BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.Com VICTAUUC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2017 vIcTAuuc COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS ; "400-lilt V. GROOVED OUTLET sip pip L A r1I FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500ps1/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½'/50 x 15mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size Style No ~Pre M 3 x. Work , sure@ Dimensions Approx. Weight Each (RIM 0 - 0 0- F 0 V . i [d? h"WHk Uiii OiHia Ii1 8zrir I 4 U1E TABLE CONTINUED FROM PAGE 139. x 1½ t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 - 84 209 83 3.2 - 2t 92 ON 0 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 - 84 209 99 4.1 - 6 13y'(a) 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 4.45 112 130 130 96 232 83 2.3 2.2 1½ (a) lu 920N 500 2.00 4.40513 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 23 2(a) fu 2 N 9 0 500 230 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 635 111 130 130 96 232 99 2.7 2.5 2½ 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 76.1 mm 920 500 2.75 4.15 5.21 3.69 10.51 4.63 84 3450 69.9 105 - 132 94 267 118 - 3.8 3(a) t 20 500 330 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 - 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) fu 2 920 500 430 3.81 5.75 538 3.69 1031 6.25 10.1 10.1 100 3450 1143 97 146 137 94 267 159 4.6 4.6 159.0 x 1½ (a) 920N 500 2.00 441 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 1 3.5 - 2(a) 920N 500 250 438 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 761 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 93 3450 69.9 111 140 130 92 239 118 43 43 92 0 500 3.50 431 530 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 08.0mm 92 o 500 430 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 92 239 155 - 4.5 1 4192 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 00 3450 114.3 96.80 146 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. $ Center of run to end of fitting. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 2W BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02.4 lictaulicr REV..N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 4/200 x 100 mm Styl P0 a JApprc,. It 24 ella ella TABLE CONTINUED FROM PAGE 4_ 165.1 X 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 - 25 3450 L 96 237 70 3.6 _ 1¼ ° 920N 500 1.75 443 5.13 3.79 9.34 3.25 8.4 32 3450 445 3 O 96 7 83 38 1 ½ a) to 92 500 2.00 4.41 5.13 5.13 3.79 934 3.25 8.4 5.4 40 3450 58 112 130 130 96 237 83 38 2A 2(a) t 920N 500 2.50 4.38 513 5.13 3.79 9.34 3.88 as 6.0 50 3450 833 111 1,30 130 96 237 99 3.9 27 mm .1 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 62L 119 12 1 132 92 1 2671 118 22 3.4 _ 3(a)to 920 500 330 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 34 88S 110 WO 0 92 267 5 46 38 4a)to 920 - 500 4.50 3.81 5.75 538 3.63 1031 6.25 105 8.4 100 3420 1143 1 97 146 137 92 267 159 48 1 38 8 2(a)t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 430 11.6 11.6 X 50 200 _ 50 69.9 JL JZ 159 122 316 114 13 52 21ha)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 430 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 53 53 76.1mm 500 2.75 5.25 . 6.25 4.81 12.42 4.56 11.6 920 3450 699 133 9 122 316 53 3(a) to 920 500 3.50 531 6.50 6.50 4.81 12.42 5.31 12.6 11.6 - 3450 2 JL 165 165 J 316 4(a) ° 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3420 U43 2 m 162 122 316 159 6.9 57 Center of run to enaaaed oioe end. female threaded outlet only (dimensions aooroximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet Is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 2W BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY. 02017 VlCTAuuC COMPANY. ALL RIGHTS RESERVED. REV_N Acnauliicr 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C,,, and JO, Values I Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C.,,K,, Values: =Q2 Where: 0 = Flow (GPM) = Pressure Drop (psi) 0 = C,. x JAT C,. = Flow Coefficient Ap = Q2 Where: -j-;• 0 = Flow (m3/hr) AP = Pressure Drop (Bar) 0 = K. x Ji K,. = Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule - -Li OUTLET SIZE H II- G8P311,.u. 11_ ½ 0.840 2 - 11 15 21.3 9.4 14 1.050 I 4 - 16 20 26.7 - 13.7 1 1.315 3' 8 - 21 25 33.7 1.8 114 1.660 5½ 6 50 48 32 42.7 42.9 41.1 1½ I 1.900 11 11 53 53 40 I 98.3 45.4 45.4 2 2.375 9 10½ 112 104 50 60.3 96 89.1 2½ 2.875 20 12½ 119 150 65 73.0 102 128.5 76.1 mm 3.000 16* - 161 76.1 138.1 - 3 1 3.500 249 237 80 1 88.9 14 15½ 213.4 203.1 1 4.500 421 401 100 I 114.3 20 22 360.8 1 343.6 It Hazen-Williams coefficient of friction is 120. 'Pipe with a wall thickness of 0.1651n14.2mm. 1 flreLock Innovative Groove System (IGS) outlet www.victaulic.com j#1taUlic viCTAuuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REVN CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures — psi/kPa 8m I. IhM1maiim ____ _____ _____ •: _____ _____ 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 - 2496 21/2-4 2.875-4.500 MI OF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 1 2065 1999 1 1599 2496 6 6.625 3.4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 34 30.40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 - 145 - 200 219.1 2755 - - - 1000 8 8.625 34 10 300 - 250 - 145 200 219.1 2065 1724 1000 - 8 8.625 34 30,40 300 - 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VlC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is full port ball valve which can be mounted on 4/100mm, 5/125mm, 67150mm and 81200 mm diameter pipe. The Style 931 comes with a 2WI65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com taulicr vIcTAuuc IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. x Am. REV_N 11.02_7 MechanicaIT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV N UPDATED 1212017 ictaulle VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L FireLock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, V4, and 1715, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the CD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, Iightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade 'E EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E' Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location - Approved Date www.victaulic.com v!cTAuuc Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02009 vlcTAuuc COMPANY. ALL RIGHTS RESERVED. REV_G 4tauIiC' 10.52_i DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 in che"mm _• Diameter ______ Dimensions - inches/millimeters 9 9 11 ____ ____ ______ 1 ¼ ½ 32 15 1 V16 30.2 1.30 33.0 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 1.0 0.45 1 346 30.2 1.28 325 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 1.1 0.50 34 20 1 116 30.2 132 38.6 2.18 55.4 1.10 27.9 3.87 98.3 2.56 65.0 1.2 0.54 1 25 1 ½ ½ 40 15 1 IM 30.2 1.42 36.1 1.95 495 1.22 31.0 4.08 103.6 2.56 65.0 1.2 1 0.54 1 3AG 30.2 1.40 35.6 1.95 493 1.22 31.0 4.08 103.6 2.56 65.0 1.2 0.54 34 20 11116 30.2 . 1.64 41.7 2.30 58.4 1.22 31.0 4.08 103.6 2.56 65.0 1.3 0.59 1 25 2 ½ 50 15 1346 30.2 1.66 42.2 2.19 55.6 1.46 1 37.1 4.60 116.8 2.56 1 65.0 1.3 0.59 1346 30.2 1.64 41.7 2.19 55.6 1.46 37.1 4.60 116.8 236 65.0 1.4 0.64 3.4 20 1 V1 - 30.2 1.88 47.8 234 64.5 1.46 37.1 4.60 116.8 2.56 65.0 15 0.68 1 25 216 x 15 65 15 1446 30.2 1.91 48.5 2.44 62.0 1.71 43.4 5.40 137.2 2.56 65.0 1.6 0.73 ltla 30.2 1.89 48.0 2.44 62.0 1.71 43.4 5.40 1372 236 65.0 1.6 0.73 34 20 1 tia 30.2 2.13 54.1 2.79 70.9 1.71 43.4 5.40 137.2 236 65.0 1.6 0.73 1 25 761 mm X ½ 15 ltia 30.2 1.91 48.5 2.44 62.0 1.71 43.4 5.50 139.7 2.56 65.0 1.6 0.73 12K6 30.2 1.89 48.0 2.44 62.0 1.71 43.4 5.50 139.7 2.56 65.0 1.6 0.73 14 20 1 34a 30.2 2.13 54.1 2.79 70.9 1.71 43.4 5.50 139.7 2.56 65.0 1.7 0.80 1 25 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com ictsuild VICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuuC COMPANY. 02009 VICTAUUC COMPANY. ALL RIGHTS RESERVED. 10.52..2 REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 PERFORMANCE Schedule 40 Steel Pipe (per UL Run ISize 1l Outlet .S ize 1% 1 8.5 32 25 2.6 1½ 1 8.5 40 25 2.6 2 1 8.5 50 25 2.6 2½ 1 8.5 65 25 2.6 76.1 mm X Hazen-Williams coefficient of friction is 120 Fire Lock® Outlet-T STYLE 922 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 182009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.523 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 1212009 iCtaUlic VICTAuLIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 10.52 Juctile Iron Threaded Fittinc - SMITH.-COOPEV INTERNATIONAL L Ductile Iron Threaded Fittings L iecifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP U Ductile iron castings conform to ASTM A536 c • L us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20t0 100 500 150 500 200 480 250 460 300 440 350 420 - 400 400 450 380 500 360 550 340 --_- 600 320 650 300 @ am Fig. 35E 3_900 Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 1 35E 3020 2.25 10 20 1.8 2-1/2-1 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow L.. Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-112x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-112x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2x1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 35F 3020 1.69 10 20 2--j 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number ______ A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 351 3006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 1 35T3020 2.25 6 12 2.4 2-1/2-1 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL0 • TOLL FREE 1-800-766-0076 0 FAX (323) 8904456 • wwsmithcooper.corn c®uS <~> APPROM Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35R13010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1 x3/4 x 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35R13012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 = .75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x1-1/4 35R13012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x x 1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-114x1x314 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35R13012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35R13014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-1!2x 1 x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x lx 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2xlx1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35R13014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4 x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35R13020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2x1x2 35R13020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35R13020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35R13020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x 1-1/2x3/4 35R13020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 a i,I r :111: Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35B13010012 1.67 1.67 1.58 20 40 0.9 lx 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 358T3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35B13012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35BT3014020 2.16 2.16 2,02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com 112 in I Size I_ Part Number A in Packing Weight lb Inner Master I_1/2 35SP3004 0.94 600 1200 0.07 13/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 I1-1/4 35SP3012 1.37 100 200 10.3 I 1-1/2 35SP3014 1.44 80 160 0.4 I 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat I I Size _in Part Number A in Packing Weight lb Inner Master I_1 35U3010 2.19 20 40 1.0 I_1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 I_2 35U 3020 1 3.12 1 6 12 2.4 c®uS 4 MPROVED LISTED A Fig. 3503 - Straight Coupling with Ribs tEa Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 - 70 0.4 1-1/4 35CP3012 2.00 35 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35RC3010004 1.69 80 160 0.3 1x3/4 35RC30 10006 1.69 60 120 0.4 1-1/4x 3/4 35RC3012006 2.06 40 80 0.6 2 xl(not hex)l 35RC3020010 1 2.81 1 20 40 1 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35HB3010004 1.06 180 360 0.2 1x3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2 x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug 113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 6 wwwsmithcooper.com I Size I in Part Number A in Packing Weight lb Inner Master I 1/2 35C 3004 0.87 300 600 01 13/4 35C 3006 0.97 200 400 0.1 I_i 35C3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 1 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 1 36 1.6 0 U C T L E C uS A A Fig. 3513- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 1 6 12 2.8 Fig. 35RX3 - Reducing Cross I Size I in I Part i I A I I in I B I in I Packing I Weight I I lb I I Inner I Master I 1-1/4x1 I 35RX3012010 I 1.67 I 1.58 15 I 30 1.2 I 1-1/2x1 I 35RX3014010 I 1.80 I 1.65 I 12 I 24 I 1.4 I I 2 x 1 I 35RX3020010 I 2.02 I 1.73 I 8 I 16 I 2.0 I Fig. 35C.8 - Cap Fig. 35BC3 - Beam Clamp I I Size in Part Number A in Packing Weight lb Inner I Master I 3/8 358C3003 0.75 100 200 1 0.3 I 1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwsmithcooper.com 114 INSTALLATION STEPS - INTO WOOD & STEEL: IINSTAL1AT10N STEPS - ILIli INlO WOOD & STEEL] Insert the appropriate nut driver into a 3/8°or 112"portable drill. Insert the SAMMYSID into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4°. 3/8°, I/2"or metric all thread rod, bolt stock. (The 112°requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot tbs. for maximumpullout in purlin steel. 177.7777-1 Insert the appropriate nut driver into a 3/8°or 1t2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4°, 3t11", Mb, M8 or metric all thread rod or bolt stock Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in puffin steel. IN-11 ISM [INSTALLATION STEPS -QMM INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre4ri11 the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, Install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CSTscrew into the nut driver. Place tip of screw into the pre-drilled hole, turn impactidrill unit to drill mode and begin insertion. When the nut driver spins freely on the CSTscrew, installation is complete. Stop and remove drill. The concrete screw Is ready to receive 1/4°, 3/8°, 1/2", or metric all thread rod or bolt stock (#14SWred nut driver used with 112'screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - hI INTO CONCRETE: Using an SDS 250 carbide tip bit ore HEX RECEIVER with a #250 carbide tip bit, pie-drill the concrete member to a depth of 2° with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pie-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drilL The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. - 0 MUM n - - 0 W--Jl Fail a. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes Into contact with the material you are Installing into, continue drilling until nut driver spins free. Installation Is then complete. Warranty requires the use of the approprIate nut driver for installations. SAMMYS FOR STEEL AL1'A Made with Tekse self-drilling fasteners - no pie-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. .0 1 V10011 king Jim rellf1red www.1PNbu1wex.conJ 1/4" 8024957 DSTRIO0 114-20x?TEKS3 1510 (20 ga.) .36-20ga 3/16" 25 125 1/4" 8025957 DST 100 114-14x1"TEKS3 446 (209a.) AN-20 ga 3116" 25 1251 1/4" 8026957 DST 150 114-14x1-IITTEKS3 910 (16 ga.) .036-209a 3/16" 25 125 114" 8027957 DST 200 _1/4-14 x 2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16' 25 1251 1/4" 8030957 TEK500 12-24x1.110TEKS5 3125 (3116) .188'-3/16" 1I2 25 125 318" 8038957 DSTRI • 114-20x1"TEKS3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125] 3/8" nsa. 8037957 eannac, DSTR1-112" 12-24x1-10TEKS5 narn tie, tsar la.aainrru,e, 1510 (3/161 1500 fineR inn... lean 1475 .066"-16ga. lfZ 25 125 ant anea fin nut. fir ant 1 318" 8040957 DST 10 114-14x1*TEKS3 446 (20 ga.) 970 (16 ga.) .03r-20 ga 3116" 25 125 3/8" 8077925 DST 10-SS 1I4-14x1"TEKS3 446 (209a.) 970 (16 ga.) .036%20 ga 3/16" 25 125] 3/8" 8041957 DST 15 1/4-14x1-1I2TEKS3 446 (209a.) 970 (169a.) 036"209a 3/16" 25 125 3/8" 8078925 DST 15-SS 114-14x1-1I2"TEKS3 446 (209a.) 970 (16 ga.) W-20 ga 3116" 25 125 3/8" 8042957 DST 20 1/4-14 x 2TEKS 3 446 (20 ga.) 970 (16 ga.) .036.20 ga 3/16" 25 125 8043957 3 /8" DST 1/4-14x2-1 I? TEKS3 446 (20 ga.) 970 (16 ga.) .03r-20 ga 3116" 25 125 3/8" 8044957 DST 30 1/4-14x3"TEKS3 446 (20 ga.) 970 (169a.) .03r-20 ga 3116" 25 125 3/8" 8045957 DST516 5116-18x1-1/4"TEKS3 1500 3/8" 8046957 TEK50 12-24x1-1ITTEKS5 3125 1/2" 8031925 DST 2.0 114-14 x 2TEKS 3 446 970 1/2" 8033925 DSTR1.0 1/4-20x1"TEKS3 1510 (209a.) .03r-20 ga 3/16" 25 125 1!? 8034925 DSTR5.16" 5/16-18x1-114"TEKS3 2220 (209a.) .036"-20 ga 3/16" 25 1251 112" 8035925 DST 5.16 5/16-180-114"TEKS3 1500 (3116") .125"-118" 3/16" 25 125 - 1/2"_ 8036925 _TEK5.0 - 12-24x1-1/TTEKS5 3125 (3/16") - .1881-3/16" 1/2" 25 125] includes retaining nut #14 Black Nut Driver Part # 8113910 1- #14 SW Red Nut Driver Part # 8114910 1500 1475 .256"-1I4 112" 25 125 .188"-3/1W 1I4 25 125 Y SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes Into contact with the material you are Installing into, continue ddltng until nut driver spins free. Installation Is then complete. Warranty requires the use of the appropriate nut driver for installations. 9~Affffyg Made with TWO self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - lIT thicknesses. fl • A standard sci-ewgun with a depth sensitive nosepiece should be used to required install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. ZZ Weoô,nionsbiibn Made in the U.S.A. IDv.er'w.1twbu1Idex.co,r - 114 8047957 SWD 100 114-14x?TEKS3 1477 (16ga.) .060-169a 3116 25 125 114 8049957 SWDRIOO 114-20x?TEKS3 1900 (209a).036-209a 3116'25125 1 318 8050957 SWD 10 114.14 xl' TEKS 3 1477 (16 ga.) .060-16 ga 3116° 25 125 318 8080925 SWD 10-SS 114-14 xi' TEKS 3 1477 (16ga.) .060'-16 ga 3116' 25 125 1 318' 8051957 SWD 15 114-14x1-1!TTEKS3 1477 (169a.) .060°-116ga 3116' 25 125 318 8052957 SWD 20 114-14x? TEKS 3 1477 (16ga.) .O60-16ga 3116' 25 318' 8053957 SWD 516 5116.18x1.114'TEKS3 2480 (20ga.) .03W-20ga 3116' 25 125] 125 [3<> 318' 6055957 SWDRP 114-20xf TEKS 3 1900 (20ga) 1500 1475 .036-20ga 3116' 25 125 1 #14SWRed Nut Driver 3 318' 8054957 SWDR1-112° 12-24x1-112'TEKS5 2375 (3116) 1500 1475 .188*-3116 112' 25 125 [j..r$> 318° 8056957 SWDR5I6° 5116-18x1-114'TEKS3 2480 (20ga.) 1500 1475 .036-20ga 3116' 25 125 Part#8114910 - 3!& includes retaining nut 8057957 SWT15 12-24x1-112' TEKS 5 2375(31161 .188'-3116' 112' 25 125 Application Product I • Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. Allows 17° deflection from vertical. Made in the U.S.A. J L 11 =1-1wame WSW &Mnrafim 01% IwerlP.vbuIIdex.comJ r E'.L JJFVI!4i r'' - 4c #14 Black IX20 X 1' Nut Driver 318' 8137957 SH-DSTR1 TEKS 3 3220(31161 1500 1475 .035' 3116' 25 125 Part#8113910 I 2368(1!? steel Vertical) 318° 8268957 SK-TEK 50 12-24x1-314' 1306(45° off Vertical) 1500(Vertical) 3116' 1!? 25 125 TEKS 5 2281(3116' HSS) 850(45° off Vertical) 2-1I2' 1585 (3116' H8545° off Vertical) 2368(1!? steel Vertical) 112' 8270957 SH-TEK5.0 12-24x1-3!4' 1306(45 off WOW) 3116" Il? 25 125 TEKS 5 2281 (3116' HSS) #14 SN Orange 1 1585(3116' HSS 45* off Vertical) Nut Driver — Part #8273910 1 3 nor compt/ v/dh ROHS equiremeMsIlnrJrJes ,etahrhrg nut S A MM Y )(-P R E S 5 Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: light gauge steel deck or pudin (22 go. .1/B'). Installs in seconds with Sammy X-Press Its Tool, saving time & installation casts. Use in applications where access to the back of the installed fastener is prohibited. le. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. EX 114' 8181922 XP 200 Sammy 1146(22ga) 185(Luminaire) .027' 125' 25 125 Metal Dedc X.Piess 200 250 (Luminaire) .056' 850 (2W Pipe) .027' 940 IT Pipe) .029' 8150922 XP 20 Sammy 1146(22ge) 185(Luminaire) :02 1475 (4' Pipe) .104'.125' 25 125 Metal Deck X-Press 20 250 (thminaire) 056 283 (Conduit 8 Cable) .029' 1500(4' Pipe) .060' Sammy 185(Luminaire) .029' 940 (?Pipe) .029' .125' 25 125 PM '> 318' 8153922 XP 35 X.Press35 1783(169a) 250(Luminaire) .056' 1475 (4'Pipe) .104' 416 (Conduit&Cable) .059' Pre-Pour Stiucturalcoiicrete@ 3000 psi Metal Deck 318' 8150922 XP2O Sammy 1146(22ga) 850(2APipe) 25 125 (Pre-Pour) X.Press20 Post-Pour Range II LWC 35 p (tbff') Metal Deck (RasPccr) I Pre,-Pour Structural Concrete 4"000 psi Post-Pour Range II LWC5 35 PCF (lbslft') j cu" The SidewinderX-Press expands to provide • Less jobsite material needed. horizontal attachment in: -16 go -3/16' steel -pudin, tubular steeL • No retaining nut required. t1 . .' 'Installs in seconds with Sammy X-Press ItsTool, • Provides design flexibility. I1 saving time & installation costs. Made in the U.S.A. Use in applications where access to the back of the Installed fastener is prohibited; ie. metal roof E deck, tubular steel, or vapor border fabric. Watctai*Jeonnenmattei - .. ww,w.Ilwbullder.cor . 318' 8293957 SWXP35 X-Press 35 1798 (16 gal 80.uminaire) .059' .125' 25 125 Purlin I 416_(Conduit&Cable) . Z*uAY 14 for of 1of ptC5 Jll11JV ® The Swivel X-Press allows you to hang plumb in extreme roof pitches: BY in z-pudin - 45 in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press Itu Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. is. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. VAfth&vffWdwaaWw area 01 W. www.lPNbulldeLcomJ 750(2' Pipe) S S . 318' 8294922 SXP2O Swivel 170 Vertical (l.uminaire) 1061 (22 ga Vert) 80i45 (Luminaire) .029' 635 (2' Pipe) .029' .125' 25 125 Metal Dedc. X- 2O 283 Vertical (Conduit & Cable) 233@ 45 (Conduit& Cable) 1250(3.1/2' Pipe) Swivel 318' 8295922 SXP3S X.Press35 1675(169 250 Vertical (l.uminaire) .029' .125' 25 125 Pwlin 1558(89OffVert) .028' 635 (?Pipe) Cable) 333 @89' (Condu8 & Cable) 117 8272957 SXP2.O Swivel 1061 (22ga Vert) .02T .125' 25 125 Met alDeck X-Press 2.0 829(45 Off Van) Swivel 1675(16gaVert) 1!? 8271957 SXP3.5 X.Press3.5 1558(89 Off Vert) .060' .125' 25 125 Purfin ' direct vertical attachment In: The Sammy X-Press expands to provide gauge) Made in the U.SA a L www.ilwhulidex.com Pa rt Number Model I1itbi. Cli' 8194910 UXPIV Universal X-Press It Tool 1 8152910 XPDB 25/64' Drill Bit 1 'Tool includes: Sleeve. Bit Recelvei Hex Wrench, and 25164' Drill Bit. APPROVAL S 8007957 GSTIO 3/8' Vertical CPVCI-112' 300 1.1/2' 8020957 SWG1O 3/8' Horizontal CPVC 1-112' 300 1-112' 8008957 GST2O 318' Vertical 2-lit 850 1-1/2' 4' 8068925 GST2O-SS 3/8' Vertical 2-lit 850 I-1t2' 8010957 GST3O 3/8' Vertical 1500 1-1/2' 1475 8009925 GST2S-380 318' Vertical 4' 1500 1-1/2' [8022925 SWG 2L318 Horizontal 3.lit-4" 1500 1-lit 8021957 SWG2O 3/8' Horizontal 2-lit-3m 1050 1-11T [1 SWG 20-88 3/8' Horizontal 2-1f2' 850 1-lit 8269957 SH-GSTICST2O 3/8' 45' Angle off Vertical 2-1/2' 850 1-lit i9957 SH-GSTICST 20 Wr 45* Angle off Vertical 4' 1500 1-117 8139957 SH-GST2O 3/8' 17' Angle off Vertical 3' . 1050 1-lit 4' 1475 1-1/2' 3/8' Vertical 4' 1500 .035' 4' 1475 .105' J 8037957 DSTRI-1123/8' Vertical 4' 1500 .035' 4' 1475 .105' [8M5 7 DSTR 5163/8' Vertical 4'1500 .037'4_1475 .105'1 8045957 DST 516 3/8' Vertical 4' 1500 188' 4' 1475 .188' 8046957 TEK50 3/8' Vertical 4'1500 .250'4'1475 .188'1 8055957 SWDR 1 3/8' Horizontal 4' 1500 .037'.4'1475 .060' [iói16 3I8' Horizontal 4'1500 037' 4'1475 .060j 8054957SWOR 1-1/23/8'Horizontal 4' 1500 .037' 4' 1475 .060' [1 Sli-oSTR1_3/8'17' Angle off Vertical 4'1500 .035' 4' 1475 .105' 8268957 SH-TEK 50 31W Vertical 2.1/2' 850 8150922 XP 20 318' Vertical 2-17 850 .027' 7 940 029' j 8153922 XP 35 3/8' Vertical 4' 1500 .060' 4' 1475 8294922SXP 20 3/8' Vertical or up to 45' 2' 750 .027'2' 635 29'1 8295922SXP35 318' Vertical or up to 89' 3-1/2' 1250 .060' 2' 635 .029' 8293957 SWXP35 3/8' Horizontal 3-11T 1250 .060' SAMMYS FOR CONCRETE. PIPE HANGER I L!59957 CST 20 3/8' Vertical . 4' 1475 3000_J 8081957SWC2O 318'Horizontal, 4'1475 3000 XP 20 3/8' Vertical 2-lit _850 Pre-Pour Structural @3000psi 8150922 XP 20 3/8' Vertical 2-lit 850 Post-Pour Range Il LWC :5 35 PCF 0bs/ft') 8150922 XP2O 318' Vertical 185 .027' ______________ 250 .035' 185 .027' 8153922 XP 35 3I8' Vertical 250 .035' 185 [92 XP200 114' Vertical 250 : J Vertical 170 .027' 8294922 SXP 20 3fir V____250 L ::_ SXP 35 318' 90* 80 .0617 SWXP 35 318 Horizontal 80 .060' 8153922XP 35 3/8'Vertical 500 .060' Max 4 trade size EMT& 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 318' Vertical 283 .027' Max 4 trade size EMT, RMC, and IMC 85 trade size rigid PVC conduit ] 8295922 SXP35318'Vertical 500 .060' Max 4 trade size EMT &6 trade sze RMC, IMC, and rigld PVC conduit r 8293957 SWXP 35 3/8' Horizontal 500 .060' Max trade size EMI & 6 trade sze RMC. 1MG, and riald PVC 8149957 CZ2000 1/4' cr318' Onto Vertical Rod Gauge No. 22 ga. 209a Nominal DecImal Equivalent .030' .036' 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL Is 3-112' SWG 25.380 Maximum pipe size in wood timberorjolxt allowed by UL is 4 'SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1!2' Complies wl NEC Standards 18 ga. 16 p. 140a-_129a- 1/8" 3MV' 114" .048' .060' .075' .105' .125' .188' .250' UI. compliance with NEC Standards. UL and FM tests were performed In compliance with NFPAI3 Standards. FastenIng requIrement 5 times weight of water-Ilted schedule 40 pips plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listd by UL were tested in plate steel that measured .188" and .118'. Subsequent testing was done for z-puriin applications in May 1997 using (.037') or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-PressP was completed using (.030') or 22 gauge steel metal deck. Sammyse Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring In high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joisttlruss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 118' smaller than root diameter of fastener. Consult the table below: Model GST2O AT 118' GST 25-380 .280' 7!32' SWG 20 .182' 118' SWG 25-380 .280' 7132' To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAINEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com MlOW7ID3ITAGW.INAJJ Technical Drawings Technical drawings are available and can be downloaded at www.ltwbuildex.com In the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 [IJ Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base, materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACl 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/Aoorovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor PAM Indeoendent code evaluation IBC®/ PRC® 2015 IBC®/ IRC® 2012 IBC®/ IRC® 2009 IBC®/ IRC®2006 LI Hilti, Inc. (US) 1-800-879-8000 1 www.uS.hllti.com I an español 1-800.879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table I - Hilti KWIK HUS-EZ I specifications'-2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dblt in. 1/4 Nominal embedment h,.,,, in. 1-5/8 2-1/2 Effective embedment h0 in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque Ti.. I ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T, is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete12345 Nominal Nominal Tension - 4N Shear - cV I'.,, = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f 'c = 2,500 psi I ' = 3,000 psi f' = 4,000 psi f 6,000 psi anchor embed. diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 1 / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete1'2'3'4'5 Nominal Nominal Tension - 4N Shear - f'., = 2,500 psi f' = 3,000 psi f' = 4,000 psi I = 6,000 psi f' = 2,500 psi I = 3,000 psi I ' = 4,000 psi I = 6,000 psi anchor embed. diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 1 / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by h. as follows: for sand-lightweight, A = 0.68; for all-lightweight, A. = 0.60 Tabular values are for static loads Only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - aN 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aN - 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors'-2 Nominal anchor Nominal internal Tensile3 Shear4 Seismic shear5 diameter thread diameter 4pN. Ov. 4V in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 UNC (16.4) (3.6) (1.6) 1/4 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension = as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V <O.64A f, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with V:s 4 0.60 f,, as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 uncracked concrete fm 1AV fRy______ Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hn. (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 8 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a - 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 Cd 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 1 0.70 0.89 0.93 5-1/2 (140) 0.98 0.83 0.72 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 ca 10 (254) 0.89 CL CO 11 (279) 0.93 1 12 (305) 0.97 1 14 (356) _ ______ ______ ______ ______ 1.00 1 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear' cracked concrete f m I RN fAV f,______ fR1 Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h,m (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 1 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 1 0.80 0.71 1 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 1 0.66 0.93 0.98 n/a N 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.98 . 7 (178 1 0.92 . 0.78 1.00 - 8 (203) 0.98 0.82 9 (229) 1.00 0.86 10 (254) 0.9001 11 (279) 0.94 12 (305) 0.98 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACl 318-14 Chapter 17. 3 Spacing factor reduction in shear, fA' assumes an influence of a nearby edge. If no edge exists, then lAy = f. 4 Concrete thickness reduction factor in shear, f assumes an influence of a nearby edge. If no edge exists, then = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espaflol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 Mechanical Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck''4'56'7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - 4N Shear - pV Tension - 4N Shear - 4V = 3,000 ps '= 4,000 psi '= 3,000 psi '= 4,000 psi F' 3,000 psif'= 4,000 psi f',=3,000 PS '= 4,000 psi anchor thread embed. diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 UNC (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 UNC (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1'23'456'78 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - 4N Shear - 4V Tension - Shear - f' 3,000 psi '= 4,000 psi f',= 3,000 PS = 4,000 Psi f '= 3,000 Psi r= 4,000 psi f= 3,000 Psi rs 4,000 Ps anchor thread embed. diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. I in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) 2-1/2 605 700 610 610 635 735 610 610 1/4E (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) 2-1/2 605 700 915 915 635 735 915 915 UNC (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h.,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by ON = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - cx.,, = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiltLca i Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2—Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Min. 3/4" C) C C') Minimum 20 gauge steel deck 1 Anchors may be placed in the upper or tower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge - distance is also satisfied. 1.1 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with GSA A23.3-14 Annex 0, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I Ii carbon steel screw anchor"2 Nominal Internal anchor thread Tensile3 Shear4 Shears diameter diameter N V in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 _ ____________ (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N. = A, 4 f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V, < 4 0.6 f,, R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V. < A 4 0.6 f A as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc.(US) 1-800.879-8000 1 www.us.hilti.com I an espanol 1-800.879-5000 1 Hilti (Canada) corp. 1-800-363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilt! KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex Dl H Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. d8 in. 1/4 (mm) (6.4) 1.18 1.92 Effective embedment2 h,in. (mm) (30) (49) 2-1/2 in. 1-5/8 Minimum nominal embedment2 h. (mm) (41) (64) in. 3-1/4 4-1/8 Minimum concrete thickness hmin (mm) (83) (105). in. 2.00 2.78 Critical edge distance C. (mm) (51) (71) Minimum spacing at critical edge distance Smnc in. (mm) 1.5 (38) in. 1.50 Minimum edge distance C d. (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. (mm) 3.0 (76) in. 2 I 2-7/8 Mininimum hole depth in concrete h0 (mm) (51) (73) Minimum specified ultimate strength f.. psi (N/mm2) 125,000 (862) in2 0.045 Effective tensile stress area ASN (mm2) (29.0) Steel embed. material resistance factor for reinforcement (0 - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 A - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 A - 0.65 0.5.3 lb 3,370 Factored steel resistance in tension N (kN) (15.0) 0.6.1.2 lb 750 Factored steel resistance in shear V 0.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V cq (kN) (1.5) Factored steel resistance in shear V lb 725 D.7.11.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V8q (kN) (2.8) Coeff. for factored conc. breakout resistance, uncràcked concrete - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 - 1.0 0.6.2.6 Anchor category - - 3 1 1 0.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, A - 0.75 1.00 0.5.3 (C) Condition B5 Factored pullout resistance in 20 We uncracked concrete6 Npr. lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) lb 340 815 Factored pullout resistance in 20 MPa cracked concrete6 Nprcr (kN) (1.5) (3.6) 0.6.3.2 Factored seismic pullout resistance in 20 We cracked concrete6 Npreq lb 275 815 0.6.3.2 (kN) (1.2) (3.6) 1 Design information in this table is taken from ICC-ES ESR.3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. 2 See figure 1 of this section. 3 The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex 0 section 0.2. 4 For all design cases, qj = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (ku) or uncracked concrete must be used. 5 For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section 0.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. 6 For all design cases, ip,, = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1.800.879-5000 1 Hilt] (Canada) Corp. 1-800.363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 1ilB&HII Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure Ii in uncracked concrete1'4'5 Nominal Tension - Nr Shear - Vr __________ f'., = 20 MPa f'., = 25 MPa f' = 30 MPa I = 40 MPa IC 20 MPa f 25 MPa f'., = 30 MPa I = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900ps1) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure Iii in cracked concretelZS.45 Nominal Tension - Nr Shear - V __________ I = 20 MPa f 25 MPa f', = 30 MPa f' = 40 MPa f' = 20 MPa f = 25 MPa f' = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p51) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A3 as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - Sels = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. H Hilti, Inc. (US) 1-800-879-8000 1 www.us.hllti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363.4458 1 www.hiltLca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck 14'5'67 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N, Shear - Vr Tension - N, Shear - Vr I = 20 MPa f' = 30 MPa f' = 20 MPa Pc = 30 MPa f', = 20 MPa f'., = 30 MPa f'., = 20 MPa I = 30 MPa anchor thread embed. diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. I in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"4•5'6•7'8 I!I Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N, Shear - Vr Tension - N, Shear - f 'c = 20 We f = 30 MPa I = 20 MPa f'c = 30 MPa I = 20 MPa I = 30 MPa f' = 20 MPa f'c = 30 MPa anchor thread embed. diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. I in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASO value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,.,,,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by a,sels = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, inc. (US) 1-800.879-8000 1 www.us.hilti.com I en español 1.800-879.5000 1 Hilti (Canada) Corp. 1-800-363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 - KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels12 Hanger rod size Mm. effective embedment h, in. Allowable load3 Ultimate load Tension lb Shear lb4'5 Tension lb Shear lb4'5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensioni configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3- Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment City / box KH-EZ1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 [KH-EZ /4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 13/8 3/8 7/16 1/4 1-5/8 100 1KH-EZ 1/4x2-1/21 3/8 3/8 7/16 1/4 2-1/2 100 1 1 All dimensions in inches. Hilti, Inc. JS) 1-800-879-8000 1 www.us.hilti.com I an español 1-800.879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiltl.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 We 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 1'/4 1130 55 Max. loads for clamp with set screw In up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs. WtJ100 3/8 We 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 1'/4 1 9/16 1'/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/411 and 11/411 Throat Openings Component of State of California OSHPD Approved c@ us LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 80 pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 ii CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25- Surge Restrainer c®us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98- Rod Stiffener Component of State of California OSHPD of C@ us USTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8° rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 D OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. 'CORONA, CA 92819 • P11: 951.131.5599 • FAX: 951.131.0330 CUSTOMER SERVICE • 800.186.5266 www.tolco.com - Fig. WO-21/2 to 200-8 Fin. 200 - "Trimline" Adjustable Band Hanner (Conner R-Line Fin. B17ONfl ®TOLcO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining Coop&B-Une Fig. 63170NF9 Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3I70INFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. / For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before before installation. Adjusting nut is easily removed. ... 7 Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) '- in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) 0/4 (20mm) thru 8 (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0k Fig. 200 Fig. 200C Fig. 200F 200-1!2 Pipe /2" (15) /8"-16 in.Iin. 31/8" (794) 2/8" .____) (667) slti)Ji Ii 1.1 II (50) 200-/4 3/4" (20) /8"-16 3/8" (794) 2/2" (635) 11 (50) 200-1 1" (25) /811-16 33/8" (85.7) 2/8" (66.7) 12 (5.5) 200-11I4 1/4" (32) I8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-1I2 11/2" (40) /811-16 3/8" (98.4) 27/811 (73.0) 14 (6.4) 200-2 2" (50) /8"-16 4/2" (114.3) 31 (76.3) 15 (6.9) 200-2I2 21/2" (65) /8"-16 5/8" (142.9) 4/8" (104.7) 27 (12.3) 200-3 3" (75) /8'-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-3I2 3/2" (90) I8"-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 1 3/8"-16 7I8" (187.3) 5" (127.0) 35 (16.0) 200-5 (125) /2"-13 9I8" (2318) 6/4" (1587) 66 (302) 200-6 (150) /2"13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) /2"13 131I8" (333.4) 8/4" (222.2) 136 (62.3) .74 Fig. 200S All dimensions in charts and on drawings are In Inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200-21ft to 200-8 ®TOLCO c®uS LISTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. (2112" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed.. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) 200-1 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part No. I 200M8-1/2 Pipe in. 1/21 Size IID I (15) Rod Size I M8 A in. 011111 3/8" (79.4) I'. I I 2I8" B (11111) I (66.7) Approx. I 11 Wt./100 (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2I8" (66.7) ii (5.0) 200M8-3M 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) MiO 31I8" (79.4) 2/2" (63.5) 11 (5.0) 200MB-1 1" (25) M8 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200Mb-1 1" (25) M10 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 1/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (64.0) 2I8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2I8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3I8" (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 (50) MB 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 (50) M10 41/2" (114.3) (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200111-31/2 31/2" (90) M10 73/9" (187.3) 51/4" (133.3) 34 (15.6) 200M4 4" (100) M10 7 /8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 9I8" (231.8) 6/4" (158.7) 66 1 (30.2) 200M-6 6" (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8/4" (222.2) 136 1 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pill- so COOPER B-Line ®TOLCcT = = = : 111111:11: Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with I8"-16 or 1/20_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada" (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Part No. 200H-2-3/8 ,J 2" Pair.c (50) Rod Size /8"-16 4/i6" A 111511 (115.9) . 3I32" B (81.7) 48 Approx.YJA 8) 200H-2-1/2 2" (50) I2"-13 423/32' (119.8) 3318" (85.7) 45 (20.4) 20011-2I2-I8 2/2" (65) 3/8"-16 55/" (134.9) 323/32" (94.4) 59 (26.7) 200H-2112-112 21/2" (65) 1/2"-13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 1 53/4" (146.0) 327/32" 1 (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"-13 5/8" (148.1) 3 1/32" (100.8) 60 (27.2) 200114-3/8 4" (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 20011-4-1/2 4" (100) /2"-13 71/32" (178.6) 419/32" (1116.7) 73 (331) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Usted to support up to 8° pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Description FP LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZTM System Compatible Program* Certified to NSF/ANS/Std 61-G MCP;VV;K SYSTEM COMPATiBLE *FBCTM System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. FPPI3, LubeRtO are registered trademarks of Fire Protection Products, Inc. FGG/BM/cz, Blaze.Maste,e, FlowGuard Gold3 and Conan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 1 0 F P P I Description Pipef it® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipef it® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Installation Specifications Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FB1 SYSTEM COMPATIBLE *FBCTU System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55g1. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPP15, LubeRt5 are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaste,e, FlowGuard Go1d5 and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Spear& Compatible indicates that ThreadFit0 CLEAR has been tested by Spearsa Manufacturing to be compatible with Flameguarde pipe and fittings. 'Th1l FP Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. III 3198 LIONSHEAD AVE THREAD CUTTING OILS OR CARLSBAD, CA 92010 TEL+1 760 599-1168 CONTAMINANTS. + 1 800 344-1822 FAX + 1800 344-3775 WW () 2013 Fire Protection Products, Inc. FPPI3. ThreadFP are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBCVA. SYSTEM COMPATiBLE FBC' System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold, BlazeMaster, and Corzan® pipe and fittings. Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-91 tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contaèt: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300.