HomeMy WebLinkAbout1969 PALOMAR OAKS WAY; ; FA120017; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120017 1969 PALOMAR OAKS Job Address: Status: PENDING WY Permit Type: FALARM • Applied • 4/4/2012 Parcel No: 2130922000 Approved: Lot #: 0 • Reference No.: • Issued: PC #: • •. Inspector: Project Title: SCHUMACKER TI-FACP REPLACEMENT Applicant: • • • Owner: JJJ ENTERPRISES • • AIR PRODUCTS&CHEMICALS INC • C/O J C SCHUMACHER CO 5335 VINEWOOD ST 1969 PALOMAR OAKS WAY ESCONDIDO CA • CARLSBAD CA 760-747-3050 • • • • • Fees ($) • Add'I Fees ($) lotal($) Balance ($) • 257 • • 0 • 257 0 1-p FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ••. • t•, SCHUMACKER 1969 PALOMAR OAKS WAY CARLSBAD, CA 92088 FIRE ALARM SYSTEM FIRE ALARM PANEL REPLACEMENT lu £ Ji# L1 f SCHUMACKER 1969 PALOMAR OAKS WAY CARLSBAD, CA 92088 FIRE ALARM FACP REPLACEMENT BILL OF MATERIALS NOTIFIER NFS2-3030 ADDRESSABLE FIRE ALARM CONTROL PANEL CSFM# 7165-0028:0224 NOTIFIER LCM-320 LOOP CONTROL MODULE AND LEM-320 LOOP EXPANDER MODULE CSFM# 7165-0028:0224 DN-7070:F • A-b N FS2-3030 Intelligent Addressable Fire Alarm System General The NFS2-3030 is an intelligent Fire Alarm Control Panel designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these applications. The NFS2-3030 is part of the ONYX® Series of products from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display (LCD) presents vital information to operators.concerning a fire situa- tion, fire progression, and evacuation details. The NFS2-3030 supports the FireWatch Series internet moni- toring modules IPDACT-2 and IPDACT-2UD and permits moni- toring of alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained provid- ing backup communication over the public switched telephone line. A host of other options are available, including single- or multi- channel voice; firefighters telephone; LED, LCD, or PC-based graphic annunciators; fire or integration networking; advanced detection products for challenging environments, and many additional options. Features Listed to UL Standard 864, 9th edition. One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. Up to 159 detectors and 159 modules per SLC, 318 devices per loop/3,180 per FACP or network node. Detectors can be any mix of ion, photo, laser photo, thermal, or multi-sensor detectors; modules can be addressable pull stations, nor- mally open contact devices, two-wire smoke, notification, or relay modules. Large 640-character LCD backlit display (16 lines x 40 char- acters) or display-less (a node on a network). Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020). Up to 54 nodes when DVC is used in network paging. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online/offline program option. Application code is saved in Flash memory. With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the CPU fails. NOTIFIER® by Honeywell NFS2-3030s, DVC audio option at right Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. EIA-485 annunciators, including custom graphics. History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. Advanced history filters allow sorting by event, time, date, or address. Alarm Verification selection per point, with tally. Autoprogramming and Walk Test reports. Optional universal 2,040-point DACT. Positive Alarm Sequence (PAS) Presignal. Silence Inhibit and Auto Silence timer options. Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Up to 1000 powerful Boolean logic equations. Supports SCS Series smoke control system in both HVAC or FSCS modes. FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. EIA-232 printer port. EIA-485 annunciator port. 640-CHARACTER DISPLAY FEATURES: Backlit, 640-character display. Program keypad: full QWERTY keypad. Up to nine users, each with a password and selectable access levels. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. ON-7070:F • 7/16/2010 - Page 1 of 8 Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 x 40) with long-life LED backlight. FLASHSCANTM INTELLIGENT FEATURES: Poll up to 318 devices on each loop in less than two sec- onds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - nine levels. Pre-alarm ONYX intelligent sensing - nine levels. Sensitivity levels: - Ion —0.5 to 2.50/6Ifoot obscuration. - Photo —0.5 to 2.350/a/foot obscuration. - Laser (VIEW®) —0.02 to 2.00/6/foot obscuration. - Acclimate PlusTM - 0.5 to 4.00/6/foot obscuration. - lntelliQuad - 1.0 to 4.00/6/foot obscuration. Drift compensation (U.S. Patent 5,764,142). Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Programmable activation of sounder/relay bases during alarm or pre-alarm. Read Status displays the level of detector cleanliness. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. FSL-751 VIEW® (VERY INTELLIGENT EARLY WARN- ING) SMOKE DETECTION TECHNOLOGY: Revolutionary spot laser design.. Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. No moving parts to fail or filters to change. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. FAPT-851 ACcLIMATEPLUSTM LOW-PROFILE INTELLI- GENT MULTI-SENSOR: Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature signal at 40°F ± 5°F (4.44°10 ± 2.77°10). Sample System Options SLC Intelligent Loop I I I DEVICES .j * * i I I ....... I FAPT-851 FSL751 NBG-I2LX FMM-1 FRM-1 xpwio xio LCD-160 Up to 32 LCD-160 I . FSP851 I/O Modules or LCD-80 or LCD-80 ...etc. . $ Displays Relay Contact EtA -4 85 I I I EIA -485 3072 annunciator/control points ~Wu l- ____ ______ 4-+• U ___ 4-lu . IILJ..JII CPLJ2-3030D display or CPU2-3030ND ACM-8R ACM/AEM.24AT LDM-32 Relay Control LEO Annunciator Custom Graphics Optional 2048-point UDACT Dual phone lines to Central Station NFS2-3030 EIA-2324 - 4jjjfl Shown in CAB-C4 with display DVC audio in CA-11 in second tier PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the HOP port, or LCD-80 in terminal mode, but not both at the same time. Page 2 of 8— DN-7070:F • 7/16/2010 FMM4-20 GAS DETECTION MODULE: Interface to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds FM Approved, Class 6320 (Stationary Gas Sensors/Detec- tors) RELEASING FEATURES: Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). VOICE AND TELEPHONE FEATURES: Up to eight channels of digital audio. 35 watt, 50 watt and 75 watt digital amplifiers. Solid state message generation. Hard-wired voice control module options. Firefighter telephone option. 30- to 120-watt analog amplifiers (AA Series). Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick 'identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram. This timesaving feature is a special software route. The FACP "learns" what devices are physically con- nected and automatically loads them in the program with default values for all parameters. Requiring less than one min- ute to run, this routine allows the user to have almost immedi- ate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Ordering Information "Configuration Guidelines" on page 3 "Networking Options" on page 4 "Power Supplies" on page 4 "Audio Options" on page 4 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 5 "Enclosures, Chassis & Dress Plates" on page 6 "Other Options" on page 6 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-CPU systems (one NFS2-3030), the display option is the CPU2-3030D. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. CPU2-3030D: NFS2-3030 Primary Display. CPU2-3030D ships with keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control key- pad. C131.12-3030 is a central processing unit and requires an AMPS-24(E) power supply. DN-7070:F • 7/16/2010 - Page 3 of 8 CPU2-3030ND: CPU2-3030 without display. VeriFire-TCD: VeriFire® Tools CD-ROM. Contains program- ming software for ONYX series products, DVC, and XPIQ. Includes local panel connection cable. Programming PC requires a serial port connection. See DN-6871. LCM-320: Loop Control Module. Adds SLCs to 3030; 3030 supports up to 5 LCM-320s and 5 LEM-320s. See DN-6881. LEM-320: Loop Expander Module. Expands each LCM used on the 3030. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-D!SF two BMP-1s, CHS-1143, two LCM- 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- 100, batteries. NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Control Module or High-Speed Network Control Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-413, or in an annunciator box, such as the ABS-21). In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. See DN-6858. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 686 1. HS-NCM-W/MF/SFIWMFIWSF/MFSF: High-speed network communications modules. Wire, single-mode fiber, multi- mode fiber, and media conversion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). See DN-6971. NCS5-W-ONYX: Standard Network Control Station, Wire. UL- Listed graphics PC with mouse, 19" color flat-screen LCD moni- tor. Order as necessary for network systems. Each NCS con- sumes one of 103 network addresses. See DN-6868 (previous NCS-W), ONYX® DN-6869. NCS5-F-ONYX: Standard Network Control Station, Fiber. UL- Listed graphics PC with mouse, 19' color flat-screen LCD monitor. Order as necessary for network systems. Each NCS consumes one of 103 network addresses. See DN-6868 (pre- vious NCS-W), ONYX® DN-6869. ONYXWorks-NW: UL-listed graphics PC workstation for stan- dard NOTI.FlRE.NET with wire media. Includes NFN Gateway wire version (NFN-GW-PC-W) and 19" color flat-screen LCD monitor. Each ONYXWorks workstation consumes one of 103 network addresses. See DN-7048. ONYXWORKS-HNW: UL-listed graphics PC workstation for wire high-speed NOTI.FIREeNET. Includes HS-NFN Gateway (NFN-GW-PC-HNW) and 19" color flat-screen LCD monitor. Each ONYXWorks consumes one of up to 200 network addresses. See DN-7048. ONYXWorks-NF: UL-listed graphics PC workstation for stan- dard NOTl.FlRE.NET with fiber media. Includes NFN Gateway wire version (NFN-GW-PC-F) and 190 color flat-screen LCD monitor. Each ONYXWorks workstation consumes one of 103 network addresses. See DN-7048. ONYXWORKS-HNSF: UL-listed graphics PC workstation for single-mode-fiber high-speed NOTIsFIREsNET. Includes HS- NFN Gateway (NFN-GW-PC-HNSF) and 19" color flat-screen LCD monitor. Each ONYXWorks consumes one of up to 200 network addresses. See DN-7048. ONYXWORKS-HNMF: UL-listed graphics PC workstation for multi-mode-fiber high-speed NOTIsFIREsNET. Includes HS- NFN Gateway (NFN-GW-PC-HNMF) and 19" color flat-screen LCD monitor. Each ONYXWorks consumes one of up to 200 network addresses. See DN-7048. NFN-GW-EM, NFN-GW-EM-3: NFN Gateway, embedded. See DN-60499. POWER SUPPLIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACR Charges 7 to 200 AH batteries. Occupies up to four addresses on an SLC, depending on configuration. Primary input power for panel. See DN-6883. BAT Series Battery: AMPS-24 utilizes two 12 volt, 12 to 200 AH batteries. See DN-6933. 88-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100-AH batteries and power supply, if needed. 30" (76.20 cm) wide x 25" (63.50 cm) high x 7.5" (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds the AMPS-24(E) power supply when AMPS-24(E) is used as a charger for 200 AH batteries. Holds up to four 100 AH batter- ies and power supply. 30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) deep; depth includes door. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55-AH batteries. Dimensions: Box: 24" (610 mm) wide x 14" (356 mm) high x 7.75" (197 mm) deep. Door: 24.125" (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625" (approx. 1.6 mm) to depth. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ACPS-610: 6.0 amp or 10 amp addressable charging power supply. See DN-60244. FCPS-24S6/-24S8: Remote six-amp and eight-amp power supplies with battery charger. See DN-6927. AUDIO OPTIONS DAA2-5025: 50W, 25 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA-5025: 50W, 25 Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. See DN-7046. DAA2-5070: 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA-5070: 50W, 70.7 Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. See DN-7046. DAA2-7525: 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAA-7525: 75W, 25 Vrms digital audio amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. See DN-60257. DAX-3525: 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570: 35W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. Page 4 of 8- DN-7070:F "7/16/2010 DAX-5025: 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070: 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DP-iB: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA-series or AA-series amplifier. See DN-7046. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA chassis. See DN-7046. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-KD: Keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN-7045. Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC and a DVC-KD (optional); and the right side houses a CMlC-1 microphone and its well (optional). See DN-7045. Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMlC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-134 (below). TELH-1: Firefighter's Telephone Handset for use with the DVC when mounted in the CA-2 chassis. See DN-7045. ADDR-134: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-64 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series 'OR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-D4: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series 'OR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-04 backbox with the ADDR-134. See DN-7045, DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See DN- 60229. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-i is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. FTM-1: Firephone Control Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See ON-6989. RM-IIRM-1 SA: Remote microphone assemblies, mount on ADP-4 (AM-1) dress panel or CAB-AM/-AMA (AM-iSA) stand-alone cabinets. See DN-6728. AA-30: Audio Amplifier, 30 watts. Switch-mode power. Includes amplifier and audio input supervision, backup input, and automatic switchover, power supply, cables. See ON- 3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 Vrms audio power. The amplifier contains an integral chas- sis for mounting to a CAB-134, -C4, or -134 backbox (consumes one row). Switch-mode power. Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. Order the AA-100 for 70.7 Vrms systems and 100 watts of power. See DN-3224. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24A1: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 pointsSee DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ON-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. Sup- ports Canadian requirements. See DN-6940 LCD-80: 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACR See ON- 3 198. SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel See DN-4867. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(S) below. See DN-6985. BEAMHKR: Heating kit for use with the reflector of FSB- 200(5) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. See DN-6985. DN-7070:F • 7/16/2010 - Page 5 of 8 BEAMMRK: Multi-mount kit, FSB-200(S) below. See DN-6985. BEAMSMK: Surface-mount kit, FSB-200(S) below. See ON- 6985. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-60412. FSI-851: Low-profile FlashScan® ionization detector. See ON- 6985. FSP-851: Low-profile FlashScan® photoelectric detector.. See DN-6935. FSP-851T: Low-profile FlashScan® photoelectric detector with 135°F (57°C) thermal. See ON-6935. FST-851: FlashScan® thermal detector 135°F (57°C). See DN-6936. FST-851 R: FlashScan® thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851 H: FlashScan® 190°F (88°C) high-temperature ther- mal detector. See ON-6936. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751 PLJFSD- 751 APL. See ON-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with.DNR(W). FSP-851RA: Same as FSP-851R but with ULC listing. FAPT-851: FlashScan® Acclimate PIusTM low-profile multi- sensor detector. See ON-6937. FSL-751: FlashScan® VIEW® laser photo detector. See ON- 6886. B224RB: Low-profile relay base. See ON-60054. B224B1: Isolator base for low-profile detectors. See ON-60054. B71OLP: Low-profile base. Standard U.S. style. See ON- 60054. B501: European-style, 4" (10.16 cm) base. See ON-60054. B200SR: Intelligent sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan® monitor module. See ON-6 720. FDM-1: FlashScan® dual monitor module. See ON-6 720. FZM-1: FlashScan® two-wire detector monitor module. See ON-6 720. FMM-101: FlashScan® miniature monitor module. See ON- 6720. FMM-4-20: FlashScan® 4-20 mA protocol monitor module. See ON-60411. FCM-1-REL: FlashScan® releasing control module. See ON- 60390. FCM-1: FlashScan® NAC control module. See ON-6 724. FRM-1: FlashScan® relay module. See ON-6 724. NBG-12LX: Manual pull station, addressable. See ON-6 726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan® six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan® six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See ON-6925. XP6-R: FlashScan® six-relay (Form-C) control module. See ON-6926. XP10-M: FlashScan® ten-input monitor module. See ON- 6923. ENCLOSURES, CHASSIS & DRESS PLATES CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through '0"). Backbox and door ordered seperately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See ON-6857. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-30300/3030ND. CA-2: Chassis for CPU when DVC is used with fire fighter's telephone. Mounts in the top two rows of a CAB-4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. ADP-413: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA-series or AA-series amplifier. BP2-4: Battery plate, required. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. CHS-4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XP10 Multi Modes. Mounts up to six modules in any CAB-4 series row. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411 UDAC: Digital alarm communicator. See DN-6 746. IPDACT-2IPDACT Internet Monitoring Module: Mounts in IPENC enclosure. Connects to primary and secondary DACT telephone output ports for internet communications over cus- tomer-provided ethernet connection. Requires compatible Tel- dat VisorALARM Central Station Receiver. Can use DHCP or static PP. See ON-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: V-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure; Black. For Red, order BB-UZC-R. See DN-3404. Page 6 of 8- DN-7070:F • 7/16/2010 DN-7070:F • 7/16/2010 - Page 7 of 8 SYSTEM SPECIFICATIONS eCipit. ___ iriiiiiiignaiing Line Circuits .... .......1 expandable toi7 Intelligent detectors..........................................159 per loop Addressable monitor/control modules .... . ......... 159 per loop, Programmable software zones.............................over 2000 ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24/-48. _2~9_ificatilons Primary input power: - AMPS-24:110-120 VAC, 50/60 Hz, 4.5 Amps maximum. - AMPS-24E: 240 VAC, 50/60 Hz, 2.25 Amps maximum. DC output: - Main 24 VDC: Up to 5.0 A - Aux 24 VDC: Up to 5.0 A —5VDC: Up to 0.15 A. NOTE: For details of DC output values, see manual 51907. JBattery charger range: 7 AH - 200 AH. Use separate cab- or batteries over 26 AHT Float Rate: 27.6 V. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. Agency Listings and Approvals These listins and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: S635 MEA: 232-06-E FDNY: COA # 6058 CSFM: 7165-0028:0224 (Commercial) FM Approved FM6320 Approved. Class 6320 for Gas Detection City of Chicago City of Denver PSB Corporation Fire Services Department (Hông Kong) Standards TheNFS2-3030 complies with the following UL Standards and NFPA 72 Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). LOCAL (Automatic, Manual, Waterfiow, and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterfiow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterfiow, and Sprin- kler Supervisory). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work) IntelliQuadiM and NOTI.FIRE.NETTM are all trademarks; and Acclimate® PlusTM, FlashScan®, NION®, NOTIFIER®, ONYX®, UniNet®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 933=1=1 We cannot cover all specific applications or anticipate all requirements. 1111111111111111311111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8 of 8— DN-7070:F • 7/16/2010 LCM-320 and LEM-320 Loop Control and Expander Modules General The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX® Series of Fire Alarm Control Panels (FACP5) with Signaling Line Circuits (SLCs). The ONYX® Series NFS-6401NF52-640 supports one LEM-320; the NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. The LEM-320 module is used to expand the NFS-640/NFS2-640 to a second loop, and to expand each LCM-320 used on the NFS-3030/NFS2-3030 - each NFS-3030/NFS2-3030 LCM-320 supports an expansion LEM-320. Features Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop (twisted-unshielded). Built-in degraded mode increases survivability. Very simple installation - plug-in style. Permits multiple loops in small enclosure. DN-6881 Al • A-35 NOTIFIER® OF by Honeywell. Specifications] Voltage: 24 VDC nominal, 27.6 VDC maximum. Loop Control Module Loop Expander Module Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2) twisted-pair wire is 12,500 feet (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2) to 18 AWG (0.78 mm2): - Distance with 12 AWG: 12,500 It (3,810 m). - Distance with 14 AWG: 8,000 It (2,438 m). - Distance with 16 AWG: 4,875 It (1,486 m). - Distance with 18 AWG: 3,225 ft (983 m). —50 ohms maximum per length of Style 6 & 7 loops. —50 ohms maximum per branch for Style 4 loop. Maximum current: for LCM-320: 130 mA; for LEM-320: 100 mA; for single SLC loop: 400 mA maximum., NOTE: Maximum short circuit - loop will shut down until short-cir- cuit condition is corrected. Maximum resistance: 50 ohms (supervised and power- limited). Temperature and humidity ranges: This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93%:t 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Product Line Information LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NF92-3030; NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. LEM-320: Loop Expander Module. Expands each LCM used on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to two loops. Agency Listings and Approvals The listings and approvals below apply to the basic LCM-320 and LEM-320. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S635 ULC: S635/CS1 18 FM Approved CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- 0028:244 (LEM-320 with NFS2-640). FDNY: COA#6025 (LEM-320 with NFS2-640) FDNY: COA#6026 (LCM-320/LEM-320 with NFS2-3030) City of Denver Hong Kong DN-6881:A1 ° 06/05/2009 - Page 1 of 2 FLASHSCAN® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I o 9001 - We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. M111=1111 a 111111111111MIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.corn Page 2 of 2— DN-6881:A1 • 06/05/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0224 Page 1 of 3 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Model NFS-3030, NFS-3030E, NFS2-3030, NFS2-3030E fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), automatic, manual, waterfiow and sprinkler supervisory services. Suitable for use as a releasing service, Emergency Voice/Alarm Communication System and Process/Energy Management Equipment. Refer to listee's data sheet for detailed product description and operational considerations. System components: AA-30/-100/-120; Amplifiers ACM-8R/-1 6AT/-24A1/-32N48A; Annunciator Control Modules ACPS-610; Addressable/Charger Power Supply ACPS-2406; Addressable/Charger Power Supply ACT-i/-2/-4/-25/-70; Audio Coupling Transformer. ADDR-B4/-C4/-D4; Doors AEM-1 6AT/-24AT/-32A/-48A; Annunciator Expander Modules AFM-i6A/-i6AT/-32A; Annunciator Fixed Modules AKS-i B; Annunciator Key Switch AMG-1/-E; Audio Message Generator AMPS-24, CPS-24; Addressable Main Power Supply APS-6R, APS2-6R; Auxiliary Power Supply ARM-4; Auxiliary Relay Module BGRA-SCS, BGRB-SCS, CEF-SCS, RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station BB-17/-25/-100/-200; Battery Box BMP-1; Blank Module BP-4; Battery Panel BP2-4; Dress Panel CA-1/-2; Chassis CAB-4 Series, EQ Series; Enclosures CHG-120; Battery Charger CHS-4U4MB/-4N/-6/-M3/-PSI-BHI; Chassis CMIC-i ; Microphone Assembly* CPU2-3030D/CPU2-3030ND; CPU Board CRE-4; Control Relay Expander CRM-4RK; Control Relay Module CRT-2; Display Terminal DAA-5025/-5070; Digital Audio Amplifiers Rev. 06-04-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an j endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 2 of 3 DAA-5025F/DAA-5025SF; Digital Audio Amplifiers, Fiber Mode DAA-507OFIDAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DCM-4RK; Dual Channel Module DP-1 B; Blank Panel DP-DISP; Display Dress Panel DPDW-1 B, DPSW-1 B, XPDP; Dress Panels VP-213, DPA-1/-1A4/-2; Dress Panels DPI-232; Direct Panel Interface DVC-AO; Digital Voice Command DVC-EM; Extended Memory DVC-EMF/DVC-EMSF; Digital Voice Command/Ext Memory DVC-KD; Keypad Board FCM-1-REL; Releasing Control Module FCPS-24S6/S8; Field Charger/Power Supply FFT-7/-7S; Fire Fighter's Telephones FIRSTVISION-LCD; Interactive Firefighters' Display FIRSTVISION-ENC; FirstVision Backbox Enclosure and Door FMM-4-20; Analog Input Module FHS; Fireman's Handset *FCM1; Addressable control module *FDMI; Dual monitor module *FMMI; Monitor module *FMM 101 Miniature monitor module *FRM..1; Addressable relay module *FTM..1; Firephone Control Module FPJ; Fireman's Phdfle Jack FZM-1; Two-wire detector monitor module HS-NCM-W/-MF/SF/-WMF/-WSF/-MFSF; High Speed Network Control Modules ICE-4; Indicating Control Expander ICM-4RK; Indicating Circuit Module lPDACT2/2UDI*lPENC; IP Digital Alarm Communicator ISO-X; Isolator Module IZE-A; Initiating Zone Expander IZM-8RK; Initiating Zone Module LCD-80, -160; Liquid Crystal Display Module *LcD2..80; Liquid Crystal Display LCM-320; Loop Control Module LDM-32/-E32/-R32; Lamp Driver Module LEM-320; Loop Expander Module MP-113; Blank Panel MPS-2413; Power Supply Module NBG-12; Series Addressable Manual Pull Station *NBGI2IJ(; Manual pull station, addressable. See DN-6726 NCA/NCA-2; Network Control Annunciator NCM-W/-F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station, Wire/Fiber NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station, Wire/Fiber Rev. 06-04-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement' or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing No. ONYXWorks-EWI-NW/NF/-HNW/-HNMF/-HNSF; Graphics PC workstation for N0T1-FIRE-NET, Wire/Fiber N-ELR; End of Line Resistors NFS-LBB/-LBBR; Battery Box PRN-6; Printer R-120/-2.2K/-27K/-470/-47K; End of Line Resistors RA-400/400Z; Remote Annunciators RKS-S; Remote Security Keyswitch RM-1/-ISA; Remote Microphone RPJ-1; Remote Paging Jack RPT-W/-F/-485W/-485WF; Repeater SCS-8; Smoke Control Station SCS-8L; Smoke Control Lamp Driver Station SCE-8; Smoke Control Expander SCE-8L; Smoke Control Expander Lamp STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B4/-C4/-D4; Trim Ring UDACT; Universal DACT UZC-256PBB-UBC; Universal Zone Coder VCE-4; Voice Control Expander VCM-4RK; Voice Control Module VS4095/*5; Keltron Remote Printer XP5-CI-M; Transponder XPC-8; Transponder Control Module XPIQ; Transponder Quad Intelligent Audio Module XPM-81-8L; Transponder Monitor Modules XPP-1 Transponder Processor XPR-8; Transponder Relay Module 7165-0028:0224 Page 3 of 3 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units suitable for high rise applications for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2 Combined with Listing No. 7170-0028:223 Rev. 06-0410 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed s\ the test results and/or other data but does not make an independent verification of any claims.. This listing is not an i endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division