Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FA090045; Permit11/10/2020 FA090045 Prmit Data City Of Carlsbad Fire Alarm Permit Permit No: FA090045 2180 RUTHERFORD Job Address: Status: ISSUED • RD • • Permit Type: FALARM Applied 8/18/2009 Parcel No: 2120702500 Approved: 8/18/2009 Lot #: 0 • Reference No.: • Issued: 8/18/2009 PC #: • • Inspector: • Project Title: CALLAWAY GOLF PH. 4 FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: CALLAWAY GOLF CO 2180 RUTHERFORD RD CARLSBAD CA Fees ($) Add'I Fees ($) • Total ($) Balance ($) 230 • • 0 • 230 .0 1/1 CALLAWAY GOLF PHASE 4 2180 RUTHERFORD RD. CARLSBAD, CA 92008 Fire Alarm Submittal 08/08/09 Submitted By; N*VA SECURITY 10744 Rockvill Street SUITE 104 Santee, CA. 92071 619-460-7414 Cont. Lie. C-10 #802053 FA010645' CALLAWAY GOLF PHASE 4 Fire Alarm Submittal Eauioment List _Qty Description Model Manufacture CSFM# 1 Fire Alarm Panel (EXIST.) 5820XL SILENT KNIGHT 7170-0559:135 4 Fire Alarm input module SDSOO-AIM SILENT KNIGHT 7300-0559:132 4 Fire Alarm Relay module SDSOO-ARM SILENT KNIGHT 7300-0559:132 2 Fire Alarm Power Supply 5495 SILENT KNIGHT 7170-0559:123 I.B. Horn/Strobe Clg Mnt multi-cd AS-24MCC WHEELOCK 7125-0785:131 11 Horn/Strobe Wall Mnt multi-cd AS-24MCW WHEELOCK 7125-0785:131 13 Strobe Cig Mnt multi-cd RSS-24MCC WHEELOCK 7125-785:141 3 Strobe Wall Mnt multi-cd RSS-24MCW WHEELOCK 7125-785:141 4 Connection to existing Duct Detectors Lot Wire 18/2Cond. (Initiation) Lot Wire 12/2 Cond. (Notification) Lot Wire 18/4Cond. (Annunciator) Lot Wire 2 #14 THWN (Underground) Model 5495 Xim Distributed Power Module ' 4 In an emergency, you need maximum power. The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-446-6444. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs: 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices UL 864 & 1481 listed CSFM approved ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the Model 5495 Distributed Power Module 4.7kL end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. D SILENT KNIGHT by Honeywell Model 5495 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging Low AC power Auxiliary capacity: 33.0 AH Low battery condition power circuit: 1 Ambient temp.: 320 to 1200 F Earth ground fault Notification 00 to 490 C Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on: Green condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 W EOL Output alternative to using the notification resistor required troubles (1-4): Yellow circuit trouble. on each Class B Approvals: Electrical Specification circuit 864 & 1481 UL: No. of inputs 2 NFPA: 72 AC input 120 VAC at 2 amps Input Output: 24 VDC at 6 amps CSFM configuration: 2 Class B or 2 Class A .Môdël 5495 Block Diagram Signal Cfrcuit Output Sl9flali Signal 1 InpUt Distributed sinaI 2 Signal ctrcuitOutput Slgnai2 Power Module 5495 Signal 3 (Optional) Sign .14 120VAC Aux. Power. TrSüblJ output LOcal F'iréCOntrOt (Alteriiativetö flOtificäilofl circuit trouble). D SILENT. This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by"Hoftywen 7550 Meridian Circle Suite 100, Maple Grove, Mn 553694927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM LISTING SERVICE CALF FIRE LISTING No. 7300-0559:123 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. *Rece 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet; installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Model SD500-ARM Addressable Relay Module Place relay app!ications anywhere on the hitélliKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibilitj to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps © 30 VDC or .6 amp © 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up 'to a flexible solution for all your fire protection needs. Model SDSOO-ARM Features Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A @ 30VDC or.6A@ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Two sets of Form C contacts. Contacts are rated at 2A @ 30 VDCor.6A@ 120 VAC. Up to 127 relays can be used or each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved Model SD500.ARM Spedftcoffons - Contact Rating: Form C 2A@3OVDC .6A@I2OVAC Standby Current: .55 mA Alarm Current: .55 mA SILENT KNIGHT Ambient 32°F to 120°F Temperature (0°C to 49°C) Mounting 4-square electrical box C:, Model SDSOO-ARM Addiessoble Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW CAUTiON REMOVE POWER PRIOR TO SERVICINO LLJ!J ED PE 4-7/8" Model SDSOO.*RM Addrewthle Rehiy Module DimensIons DSILENT KNIGHT 1" 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350218, Rev. 11/01 FAX: 763493-6475 World Wide Web: http://www.sflentknight.com Copyright © 2001 Silent Knight SD500-AIM & SD500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the SD500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 500 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9"Wx4.9Hx1"D (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 02 (120.1 g) Color. Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8W x 6.4 H x 1.8 D cm) Weight: 1.602 (45.4 g) Environmental Operating Temperature: 32°F - 120°F ((rC - 49°C) Humidity: 10% - 93% non-condensing sriooA1M SDSOO.MJ11 Approvals NFPA7I &NFPA72 UL 864 CSFM 7300-0559:132 MEA429-92-E Vol. IX FM Approved for use with the 5820XL SILENT KNIGHT liv SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knights lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs Ordering Information 5820XL 513500-AIM Input Module 5808 Addressable input module with ivory 5700 cover plate. SD500-MIM Input Module Addressable mini input module. StLNT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev D. subject to change without notice. For more information, contact Silent Knight @2008 Honeywell International Inc by HOn5VW8I 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0559:132 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM SD500-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SD500-MIM Addressable Input Modules Models SD500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models 5D505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC SD505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XL: 7300-0410:145 Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification Series RSS and RSSP Strobes and Strobe Plates F C 1*J1 I1 1". Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15130!75!110cd or the high intensity MCWH strobe with field selectable 13511 85cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15!30/75/95cd or the high intensity MCCH strobe with field selectable 1151177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Seiies RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Tnmplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. =A 10 <~> a I1EA APPROVED S5391 151-92-E 7125.0785:141 7300.0785:154 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADAINFPNUFCIANSI compliant Meets OSHA 29 Part 1910. 165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30175/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VOC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE:AII CAUTIONS and WARNINGS are identified by the symbol AL All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING This PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH 10 YOU ANDIOR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Currenr RSSIRSSP -Wall Mount Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH RSSIRSSP 24VDC Models I I I I I I 1575cd 15cd I 30cd I 75cd I 110cd 135cd I 185cd 15cd I 30cd I 75cd I 95cd 115cd I 177cd UL max* 0.090 0.060 0.092 1 0.165 1 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSSIRSSP RSSIRSSP Wall Mount 24VDC * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating isthe maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 'ide 0.152 listed voltage (1 6v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.255 see installation instructions. Table 2: AudibleslSpeakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6!GI0 Speakers ET-1 010/1080, E70, ET70 Chimes CH70 Wiring Diagrams ERIES RSSIRSSP APPLIANCE FROM + TO NEXT PRECEDING - APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE + NAC SYNC CIRCUIT I OUT r .our1 FACPg 0+ 0- AUDIBLE 0 L 0,mIUSI ØNUS2 0 * IN 2 JIRoSE NAC CIRCUIT RETURN SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Sftbe NAC Or. SR S riø+ I I I I F I 1DSM#2 -r? - A Strobe NAG Or. fJS_,SL_ C non M P Strobe NAG Cir. DSM Interconnecting wiring shown. Maximum of twenty (20) TROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ _____________ + APPLIANCE PRECEDING I I II - OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + - 0 + - STROBE AUDIBLE STROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + PREOUNNO + TONBET wpuANcEcR - ___________ AWU.N1 CE F.AcP - OR EM + TO NEXT FROM +_11___ PRECEDING STROBEOR - - t 1 r - - - EOLR- MDI)ULB. POWER SLFPLYORFAcP • LI LI STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS-24-8MC. SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F + STROBE - STROBE Strobe A NAC Circuit C 0- P OLR V EM Audible SERIES RSS!RSSP APPLIANCES SYNCHRONIZED WITH PS-121244CP or PS-121244MP Series PS-12124-8MP OUTPUTS AS FISS F 1-4 10~m EOLR - 4-CI.ASS A AS C 2-c_SS IiIRSS I1 P II RSS Sales PS-12124-BMP Specifications and Ordering Information M d I 0 e Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE M ounting Options Square Round Agency Approvals - UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G.H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,FG.H,J.N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W.FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X I 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCWH-FR 3465 X - X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCWH-FW 3464 X X 1351185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP-2475W-FW" 3034 X - C 180@ 77-F X X - X B,D.E,F,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15130/751110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM, DSM or PS-i 2/24-SC Pot PS-1 2/24-8MR # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. RTCflflC(S ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shalt produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable sethngs and shall be rated per UL Standard 1971 at 15/30/75/llOcd or 135/1 85cd for wall mount and 15/30/75195cd or 11 5/1 77cd for ceiling mount The selector switch for selecting the candela shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, orthe SHBB Surface Backbox. If required. an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mountto either a standard 4 inch square backbox forfiush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to thange without notice in accordance with Wheelock, Inc. standard terms and conditions. rJArcA WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA 50410 RSSIRSSP 02108 Cooper NotificationisWheelOCk(MCJ SAFEPATH wAvfsT COOERNotification CALIFORNIA DEPARTMENT OF FORFSRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS.MCC *ZRSMCW, *ZRS..MCCH and *ZRS..MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12= 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 15=5cd, 1575=15175cd on axis, 3030cd, 7575cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, 'ZRS-MCW: Selectable 15cd, 30cd, 75cd or ll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS.MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS..MCJL: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCCH: Selectable 115cd, 177cd Flash rate . 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12124, DSM-12f24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification Series AS Audible Strobe Appliances and Series AH Audibles .' SERIES AS ij SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Weelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADAINFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/1lOcd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL 'Regulated Voltage Range using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18AWG wires For Weatherproof Series AS, See Datasheet S9004 ®T7.T MCA " APPROVED E5946 151-92-E 71250785131 S5391 NOTE:,AII CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. £& WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION. INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of ito 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32'F to 12017 (0C to 49C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC!FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0 -33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0 -33.0 75 @ 31-F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA dBA Per UL 464 @l0ft @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 3: Average RMS Current 24 VDC Models Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.160 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA ULmax' 0.080 0.121 0.088 0.125. 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA Med (95)E24vd 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low(90) 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA ULmax 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible I Wall Mount Audible Strobe AH-12 I AS-121575W High (99) 0.163 0.260 ~1L!Ivdc High (99) dBAUmax' 0.192 0.320 Med (95) 12 vdc 0.076 0.195 ULmax' 0.108 0.275 dBA 12 vdc 0.039 0.175 UL max' 1 0.058 0.265 dBA Table 4: Average C urrenr (AMPS) For Series ASWP5 High dBA Medium dBA Low dBA Voltage Setting Setting Setting (99) dBA (95) dBA (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (iSv for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROMIJ +DTO NEXTO - APPLIANCED PPLIANCEO O OR FACPD R EOLRD PRECEDI NGO SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12/24-8MP ASO R950 touD OUT RITSO FO - [-B~Mm-4-CLASSO -B-13 ASO R5 co SO 2-C ASS13 PD ASO SerilO P5-12/24-S PD or p5-12/24-,MS SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASSA" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE FIJ OSSU OSTPOBSO AO SttebeO MAcc co Circuit[ UdLb sO PD AudibleO 5dib sO NAtO Cl rcoi to SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES D$M 910 FLI Strobe NAC Ci AD co PD Audible c RSM #20 Strobe NAC .yflcO Audible NAC S robe AE-±1:â synccl flI DSM Interconnecting wiring shown. Ma:imtirn twenty (20)0 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationen the power supplies refer to Installation Instructions P84662 for PS-24-8MC. Specifications and Ordering Information Model Number Order Code Strobe Candela Non- Sync DSM Sync w/SM, or 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting Options*** Agency Approvals S-24MCW-FR 9024 15/30/75/110 X X X - X - ABDE,F,G,HJ,NO,R,X X X X X X S-24MCW-FW 9025 15/30/75/110 X X X - X - ABD,E,F,G,H,JN,O,R,X X X X X X S-24MCWH-FR 3468 135/185 X X X - X - A,B,DE,F,G,H,JNO,R,X X X X X * S-24MCWH-FW 3469 135/185 X X X - X - A.BD,EF,G,H,JN,O,R,X X X X X * £-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,E,F,G.H,JNO,R,X X X X X X AS-121575W-FR 7410 15(75onAxis) X X - X X - A,B,D,EFGH,JN,O,R,X X X X X X S-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F.GH,J,N.O,R.X X X X X * S-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D.E,FGH,J,N,O,R.X X X X X * S-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,FGI-I,J,N,O,R,X X X X X * ¼SWP-2475W-FR° 9012 75 @ -31°F X X X - X - I (see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X ABD,E,FG,HJNO,R,X X X X X X ¼H-24-W 7893 - X X X - X X A,BDEFG,H,J,N,0R,X X X X Ix X ¼H-12-R 7891 - X X - X X X ABD,E,FG,HJN0R,X X X X X X H-12-W 7894 - X X - X X X A,BDEF,G,H,J,N,OR,X X X X X X H-24WP-R°° 7416 - X X X - X X K X X X X ¼H-12WP-R° 7415 - X X - X I X X I K jx X X X -For atherproof Series AS/AH specifications see data sheet S9004. TENDING "Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 AS/AH 10/07 Cooper Notification is Wheelock' fMCj SAFEPATH wav COOERNotification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - - LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc.,273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415,-1230,-2430, -121575,-241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. 'Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. 'Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and 'ASWP-2475c audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, 'ASWP-24MCWH, and 'ASWP-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. 'Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15175cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 1 10c MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at -40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audibleMsual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 10-01-07 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FIRE ALARM SYSTEM RECORD OF COMPLETION 1ILE COPY Name of protected property: _Callaway Golf HQ Building (Phase 1 through 4) Address: 2180 Rutherford Road Representative of protected property (name/phone): Phil Harris 760 930-5287 Authority having jurisdiction: Carlsbad Fire Department Address/telephone number: 1635 Faraday Center, Carlsbad, CA 92008 760 6024665 1. Type(s) of System or Service X NFPA 72, Chapter 3—Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3—Emergency Voice/Alarm Service Quantity of voice/alarm channels: ____________ Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 6— Auxiliary Indicate type of connection: Local energy ______ Shunt _______Parallel telephone Location of telephone number for receipt of signals: NFPA 72, Chapter 5— Remote Station Alarm:_____________ Supervisory: _____ NFPA 72, Chapter 5— Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted - X NFPA 72, Chapter 5— Central Station Prime contractor: Mace Central Station Central station location: 401 West Lincoln Ave.. Anaheim, CA 92805 Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio X Digital alarm communicator Two-way radio ______ Others Means of transmission of alarms to the public fire service communications center: Carlabad Fire Emergency 858 756-1126 System location: West Employee I nhhy (NFPA Record of Completion 1 of 4) Organization name/phone Representative name/phone Installer Nova Security Co Hill 619 448-3007 Supplier Silent Knight Service organization Nova Security Cory Hill 619 448-3007 Location of record (as-built) drawings: 2180 Rutherford Road, Carlsbad, CA 9200X Location of owners manuals: Same Location of test reports: Same A contract, dated ____ for test and inspection in accordance with NFPA standard(s) No(s). dated , is in effect. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Cory Hill on 9-5-09 ,includes the devices shown below, and has been in service since 9-5-09 X. NFPA 72, Chapters (circle all that apply) ...X NFPA 70, National Electrical Code, Article 760 ..X. Manufacturer's instructions - Other (specify): Signed: 1 Date: _9-8-09 Organization: (Nova Security Record of System Operation All operational features and functions of this system were tested by_Cory Hill c 9-8-09 and found to be operating properly in accordance with the requirements of: X. NFPA 72, Chapters (circle all that apply) .X.. NFPA 70, National Electrical Code, Article 760 ..X. Manufacturer's instructions - Other (specify): Signed: Organization: Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 3-5) Quantity. ..&... Style: _4 Class:- B.- MANUAL 2 Manual stations ______ Noncoded, activating ______ Transmitters ______ Coded _____ Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: Partial: FACP, FAPS & Door Holders 6 Smoke detectors ______ Ion X Photo 27 Duct detectors Ion X Photo _____ Heat detectors FT _____RR FT/RR RC (NFPA Record of Completion 2 of 4) W 5 Sprinkler waterfiow switches: _____ Transmitters _____ Noncoded, activating _____Coded (e) ________ Other (list): 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR ______ Coded stations ______ Noncoded stations, activating transmitters Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) 7 Coded valve supervisory signaling attachments Value supervisory switches, activating transmitters (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) _______ Fire pump power (0 -Fire pump running ______ Phase reversal Engine-driven fire pump: _______ Selector in auto position Engine or control panel trouble -Fire pump running Engine-driven generator: ______ Selector in auto position (1) _______ Control panel trouble ______ Transfer switches Engine running Other supervisory function(s) (specify): - 6. Alarm Notification Appliances and Circuits Quantity and class (see NFPA 72, Table 3.7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 205 Style:______ Class: ______ Bells Inch Speakers Horns Chimes Other: (NFPA Record of Completion 3 of 4) 205 Visual signals Type: Strobes 122 with audible 83 wio audible (g) 2 Local annunciator 7. Signaling Line Circuits Quantity and class (see NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: 33 Style: 4 Class: B 8. System Power Supplies Primary (main): 120 VAC Nominal voltage: 98 VDC Current rating 2 Amp Overcurrent protection: Type: Circuit Breaker Current rating: 20 Amp Location: West 2nd Floor Electric Room above Fire Control Panel Secondary (standby): X Storage battery: Amp-hour rating: 1 8AH for FACP @ 7AH for FAPS (7 FAPS) ______ Calculated capacity to drive system, in hours: 689 & 2.75 24 ___________ 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software Operating system software revision level(s): XP Application software revision level(s): 9.09 Revision completed by: (name) (firm) 10. Comments: Li central station or alarm service company or installation contractor/supplier (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: (signed) for central station or alarm service company or installation contractor/supplier (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) (NFPA Record of Completion 4 of 4)