Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; AS090135; Permit2/11/2021 - AS090135 Permit Data City of Carlsbad .; . Sprinkler Permit . . Permit No: AS090I.35 RUTHERFORD . .2180 Job Address: . . Status: ISSUED RD Permit Type: SPRINK . . Applied 10/26/2009 Parcel No: 2120702500 Approved: 10/26/2009 Lot #: 0 . . . Reference No.: . . . Issued: 10/26/2009 PC #: Inspector: . Project Title: CALLAWAY GOLF T.I. FIRE SPRINKLER PLAN CHECK & • . INSPECTIONS • • Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 • • Owner CAL LAWAY. GOLF CO 2180 RUTHERFORD RD CARLSBAD CA Fees ($) Add'I Fees ($). : Total ($) Balance ($) 130 0 . 130 0 1/1 X ictsulicr Xr. 7AUTOMATIC SPRINKLERS ROTECTION PRODUCTS V27, K5.6 Models V2703, V27041, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION 27C 8 Recessed Pendent See Victaulic publicaumn 10.01 '. V2701 icr delaita. V2708 Pendent V2103 V2704 Upright These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- tern for standard commer- cial applications. They are available with either stan- dard or quick response bulbs. The design incorpo- rates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. The die Cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available In various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to VV (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707, V2708 Style: Pendent. Upright or Recessed Pendent Nominal Orifice Size: 1/2' (13 mm) K-Factor. 5.6 Imp. (8.1 S.1.i Nominal Thread Size: ½' NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kP Mm. Operating Pressure: 7 psi (48kPa) Temperature Rating-. See chart an page 2. MATERIAL SPECIFICATIONS Upright Deflector. Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: O Standard: 5.0 mm O Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: 0 Open End: V27 O Recessed: V38, V38-3 0 Socket: V27 Finishes: 0 Plain brass O Chrome plated 0 White painted" a Custom painted** Lead** 155,200, 286SR Only: WaX** 0 Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K.Factor when pressure is mea Sureci in Bar. multiply Si. units by 10.0. Tcflon is a registered trademark of Dupont Co. UL Usted for corrosion resistance in 80 configurations. VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY - Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905.884-7444 Phone: 32.9-381-1500 Phone: 610.559-3300 Phone: 65.6235-3035 Fax: 610-250-8817 Fax: 9058849774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@viclaulic.com e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@viclaulic.com e-mail: vicap@victaulic.com - 2544 Rev.D 8103 5 Registered Trademark of Victaullc opsgm euui viciauuc nimee In uan. APPROVALSILISTINGS Nominal Approved Temperature Ratings °FPC 3 Orifice Size K.Factor Inches Imperial Deflector Model millimeters S.LA Response Type UL FM ULC NYCIMEAt CSFM § ½ 5.6 135-360 135-360 135-360 135- 360 135-360 V2703 13 8,1 Standard Upright 57-182 57-182 57-182 57-182 57-182 ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8.1 Standard Pendent 57-182 57-182 57-182 57-182 57-182 ½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135 -360 V2707 13 811 Standard UptoV4'Adjustment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8.1 Quick Upright 57-141 57-141 57-141 57-141 57-141 ½ 5.6 135-286 135-285 135-286 135-286 135-286 V2708 13 8.1 Quick Pendent 57-141 57-141 57-141 57-141 1 57.141 ½ 5.6 Recessed Pendent 135 -200 135-200 135 -200 135 -200 135 -200 V2708 13 8.1 Quick Up to IN Adjustment 57 -93 57 -93 57-93 57-93 57 - 93 1 ½ 5.6 Quick Recessed Pendent 135-200 No 135-200 135-200 5793 135-200 V2708 13 8,1 UptoWAdjuttmcflt 5793 Ustings and approval as ofpnnting. cx All are approvco open, cxccpc RH areas OCSlgflatcu no. For K-Factor when pressure Is ITICaSIJrCd In Bar, multiply S.I. units by 10. t MEA #62-99-E. § CSFM #76900531:112 —J RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown In adjacent table. Temperature — °FI°C Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 68 100 38 Red Intermediate E 175 150 55 Yellow Intermediate F 200 93 150 65 Green High - 285 141 225 — 107 Blue Extra High t K 360 182 300 149 Purple - M Open : No Bulb ; stanoara response only. All arc approved opcn, except for areas designated 'No' — 150/65 if wax coatcd. ORDERING INFORMATION Please specify the following when ordering: 0 Sprinkler Model Number 0 K-Factor 0 Sprinkler Finish 0 Style 0 Thread Size 0 Escutcheon Finish O Temperature Rating 0 Quantity 0 Wrench Model Number . Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Viclaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. Tire owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the cunent National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10-2 I DIMENSIONS (6C 1W 2W (41 mm) (60 mm) 17M (37 mm) (25 mm) Standard Pendant. V2707, V2708 Standard Upright -V2703, V2704 23b (60 mm) Max. Hole 2 (51 mm) Mm. Hole I ____________ __________________ _______ I V.n Ye (17 mm) (14 mm) Typical Ceiling Tile t t p We I Ve Finished Surface (30 mm) (43 mm) MAXIMUM RECESS 2''s (75 mm) - MAXIMUM EXTENSION ½" Adjustment Recessed . V2707, V2708 (Drawing not to scale) - VLfuf g VLEUO (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V311-3 Recessed V27 Open End V2701,V2708Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright 40.10-3 DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 10' I I I I I I 3,0 m 8' 2,4 m 7psi 48 kPa 6' 1,8 m 15 psi 103 kPa 4, 1,2m 30 psi ------ 207 kPa 2- 0.6 m 0 2' 4' 6' 6' 10' 12' 14' 0,6m 1,2m 1,8m 2,4m 3,0ni 3,7m 4,3m MODELS V2703, V2104 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 10' 3.0 m 2.4 m 7 psi------ 48 We 6' - 1,8 m - - - - 15 psi 103 kPa 4' - 1.2 m - - - 30 psi ------- 207 kPa 2 0.6 iii• C 0,6m 1,2m 1,8m 2.4m 31m 3,7m 4.3m 4,9m NOTES: Data shown Is approximate and can vary due to differences in installation. These graphs Illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic. FireLock Automatic Sprinklers. They are provided as Information for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific Information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. AN products to be installed in accordance with current Victaulic irtstallationiassembly instructions. Victaulic reserves the right to change product specifications. designs and standard equipment without notice and without incurring obligations. 40.10-4 tqco /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series DS-1 - 56 K-factor Dry Type Sprinklers Standard Response, Standard Coverage General Description The Tyco5 Series OS-i, 5.6 K-factor, Standard Response, Standard Cover- age, Dry Type Sprinklers are decorative 5 mm glass bulb automatic sprinklers designed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation orcause it to operate prematurely. Page 1 of 8 standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3255 - (Pendent) TY3155 - (Upright) TY3355 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi"2 (80,6 LPM/bar') Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated JANUARY, 2008 Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing . . . . Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw ........Bronze Deflector.................Bronze Frame...................Bronze Guide Tube.........Stainless Steel Water Tube.........Stainless Steel Spring.............Stainless Steel Sealing Assembly ................ Beryllium Nickel w/Teflon* Escutcheon ..........Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 TFPSOO Page 2 of B TFP500 SPRINKLER FINISH TY3255 Pendent TY3255 Pendent TY3355 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector-to-Ceiling (Ref. Fig. 3) wl Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) WI Deep Escutcheon TY3155 Upright (Ref. Fig. 10) WIO Escutcheon w/o Escutcheon (Ref. Fig. 8) (Ref. Fig. 11) Temperature Rating Bulb Color Cede Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F/57°C Orange 1.2.3,4 1.2.4 1.2.3.4 1,2,4 1-12-,3-,4 1*, 2*, 4 155°FI68*C Red 1,2,3,4 1,2,4 1,2,3,4 1.2.4 1*,23,4 1*.2*.4 175°F/79'C Yellow 1.2.3.4 1.2.4 1,2,3.4 1,2,4 £2'3,4 1*,2*,4 2000F/93*C Green 1,2,3.4 1,2.4 1,2,3.4 1,2.4 1*, 2*. 3,4 1*, 2*, 4 286*F/141*C Blue N/A 1,2.3,4 1,2.4 1 2 3-,4 2-.4 360°F/1820C Mauve N/A 1.2,3,4 1.2,4 1*, 2-,4 1*, 2*, 4 Notes: Listed by Underwriters Laboratories. Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS-1, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH .PIN INLET GASKETED SPRING PLATE SEAL - ---- YOKE SPRING CASING WATER TUBE INSERT GUIDE TUBE BULB 7 SEAT FRAME ; 5 m BULB VENT HOLE - COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY WRENCH RECESS WRENCH FLAT PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W-TYPE 7 SPRINKLER WRENCH 2-1/4' DIP. (57,2 mm) SPRINKLER FITTING (REFER TO DESIGN CRITERIA SEC11O' FACE OF SPRINKLER FITTING ORDER LENGTHS 3-1/2't048° (88,9 to 1219,2mn IN 1/4' (6,4 mm) INCREMENTS FACE OF CEILING 3" DIA. (76,2 mm) (REFER TO DESIGN cRITERIA SEC11OP FACE OF SPRINKLER FITTING ORDER LB'IGThS 3-1/2' to 48° (88,9 to 1219,2 mn IN 1/4"(6,4 mm) INCREMENTS (REFER TO DESIGN CRITERIA SEc11O ,--- FACEOF L-i- SPRINKLER FITTING L,LjjJr I ORDER LENGTHS: I 2-1/2" to 48" 1-3/4° DIA. (63,5 to 1219,2 mm) (44,5 mm) IN1/4"(6,4mm) - INCREMENTS I I FACE OF CEILING 27/8' DIA. (34,9* 3.2 mm) (73,0 mm) FIGURE 3 TY3255 PENDENT wi STANDARD RECESSED ESCUTCHEON (34,9 ± 3,2 mm) 1-3/8° ± 1/9' 3-5/8° DIP. (92,1 mm) FIGURE 4 TY3255 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON, FACE OF CEILING 2-W18°±1/8° 3° DIP.. (55,6 ± 3,2 mm) (76.2 mm) FIGURE 5 TY3255 PENDENT wi STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r -------- FACEOF • SPRINKLER I I' I I I FITTING L .1 ORDER LENGTHS: 3-1/2' DIA. 1/2' to 46° (88,9 mm) (12,7 to 1168,4 mm) 2-1/2 DIA. IN 1/4' (6.4 mm) (635 II INCREMENTS I FACE OF I CEILING 4-1/4"* 1/8' (108.0 ± 3,2 mm) FIGURE 6 TY3255 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER L4J FITTING ORDER LENGTHS: 5 to 48' (127.0 to 1219.2 mm) IN 1/4' (6,4 mm) INCREMENTS MINIMUM 1-3/4' (44,5 mm) DEFLECTOR TO CEILING FIGURE 7 TY3255 PENDENT w/o ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5' to 48' (127.0 to 1219.2 mm) IN 1/4'(6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3155 UPRIGHT wlo ESCUTCHEON TFP500 Page 5 of 8 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS4 Sprinklers and the branch line. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40°F/40C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 400F14°C - Ref. Figure 14): 12 inches (300 mm) when the tem- perature within the protected area is 200F/29*C .18 Inches (450 mm) when the tem- perature within the protected area is -40°F/-40°C .24 inches (600 mm) when the tem- perature within the protected area is -60°F/-510C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the protect- ed area may be determined by Interpo- lating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED HEATED AREA - 1INCH DSB-2 NPT TEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES SECTION) FIGURE 12, SPRINKLER FITTING IN HEATED AREA RUN OUTLET PLUGGED 1 INCH NPT TEE TO DRY (SEE DESIGNSYSTEM CRITERIA SECTION) AREA i SUBJECT I DSB-2 TO INTENDED I FOR FREEZER FREEZING STRUCTURES U..'_ FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF r21 SPRINKLER - FITTING HEATED EXPOSURE AREA LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 14, EXPOSURE LENGTH STRAP TIES (ENDS ON j- OPPOSING / SIDES OF BOOT) I DSB-2 BOOT ADHESIVE ARANCE HOLE 3/4. ULATED EEZER STRUCTURE SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER 1-3/4' DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE I STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON DS-1 SHOWN WITHOPPOSING SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER Page 6 of 8 TFP500 Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following Instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other Important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb Is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 Inch (1.6 mm) for the 135°F/570C rating to 1/8 Inch (3,2 mm) for the 360°F/182°C rating. A 1 inch NPT sprinkler Joint should be obtained with a minimum to maximum torque of 20 to 30 ft. tbs. (26.8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment In an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit Step 1. Pendent sprinklers must be Installed only In the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be Installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector Is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, uses W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 Is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer- piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the Inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tyco® Series OS-i Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tam main control valve for mainte- nance work on the fire protection sys- tem that It controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole Is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weep- age pest the Inlet seal and that the sprinkler needs to be removed for de- termining the cause of leakage (e.g. an Improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprin- kler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of theirfire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation (e.g., NFPA 25), In addition to the standards of any other authorities hav- ing jurisdiction. The installing contrac- tor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be Inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP500 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly Installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty Is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been Installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or Inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, Strict liability or under any other legal theory, for incidental, Indirect, special or consequential dam- ages, Including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and In no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty Is made In lieu of any and gil other warranties. ex press or imeiled, including warranties of merchantability and fitness for a This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect In products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, In whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers Contact your local distributor for availability, and please specify the following: 1. Sprinkler. Model/SIN. Standard Response, Standard Coverage, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per FIgures 3 through 11, as applicable. After the mea- surement is taken, round it to the nearest 1/4 Inch Increment. Inlet Connection (1 Inch NPT or ISO 7-Ri) Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 Inch NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) Page 8 of 8 TFPSOO P/N 60- XXX - X - XXX SPRINKLER ESCUTCHEON MODEL/SIN I I FINISH FINISH (2) I I ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 18.75" r187 372 37.25" 480 48.00" 96 Pendent W/ Standard TY3255 Escutcheon (1" NPT) (Fig. 5) 93 Pendent wi Deep TY3255 Escutcheon (11" NPT) (Fig. 6) 97 Pendent W/ Std. Recessed TY3255 Escutcheon (1" NPT) (Fig. 3) 92 Pendent w/o Escutcheon j TY3255 - (1" NPT) (Fig. 7) 94 SIdewall W/ Standard 1Y3355 Escutcheon (1" NPT) (Fig. 9) 53 Sidewaliw/Deep TY3355 - Escutcheon (1" NPT) (Fig. 10) 54 SIdewall w/o 1Y3355 - Escutcheon (V NPT) (Fig. 11) I98 Upright w/o Escutcheon I TY3155 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 3 WHITE (RAL9O1O)* WHITE (RAL9O1O)" 2 1 NATURAL BRASS BRASS PLATED TEMPERATURE RATING (3) 135F/570 155F/68C 175F/79C 200F/93C 286F/141C 5 360F/182C NOTES Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each Individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch Increment. Escutcheon Finish applies to sprinklers provided with escutcheons. 286F/141C and 360/182C temperature ratings apply to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES OS-I, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-RI Connection, e.g., 1-60-961-1-180) 0 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446