Loading...
HomeMy WebLinkAbout1050 AUTO CENTER CT; ; AS100113; PermitCity of Carlsbad Sprinkler Permit Permit-No: ASI00II3 1050 AUTO CENTER Job Address: Status: ISSUED CT Permit Type: .SPRINK Applied 9/10/2010 Parcel No: 2110801100 • Approved: 9/10/2010 Lot #: 0 Reference No.: Issued: 9/10/2010 PC #: •. Inspector: Project Title: LLOYD'S AUTOMOTIVE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: FIVE STAR FIRE PROTECTION INC HELIX LAND CO LTD UNIT C/O GREGORY T LAMBRON 1040 S CYPRESS ST P 0 BOX 15453 LA HABRA, CA SAN DIEGO CA 714-441-1315 .• Fees ($) Add'I Fees ($) Total ($) Balance ($) 210 0 ••• 210 0 Area of Sprinkler Operation: 2500 sqft System Type: JJ Wet Density: .40 gpm/sqft Area per Sprinkler: 85 sqft SPRINKLER or NOZZLE Hose Allowance Inside: 100 gpm Make: VIKING Hose Allowance Outside: 400 gpm Size: Rack Sprinkler Allowance: 0 gpm Temperature Rating: 0 Dry []Deluge 0 Pre-Action Model: MICROMATIC 3/4 in K-factor: 8.0 155 OF FIVE STAR FIRE PROTECTION HYDRAULIC DESIGN INFORMATION SHEET Name: LLOYDS AUTO SPECIALTIES Location: 1050 AUTO CENTER CT. CARLSBAD, CA 92008 Building: EXISTING SPRINKLERED Contractor: FIVE STAR FIRE PROTECTION File Name: LLOYDS AUTO SPEC..the Construction: 0 Combustible IJ Noncombustible Occupancy: S-I AHJ: CARLSBAD FIRE DEPT. Date: September 09, 2010 System No.: SPRAY BOOTH Contract No.: I Drawing No.: FS-1 Calculated by: TERRY Ceiling Height 9 ft SYSTEM DESIGN fj NFPA 13: 0 Light Hazard Ordinary Hazard Group: IN Extra Hazard Group: 2 Figure: Curve: Other (Specify): Specific Rulling: Made By: Date: CALCULATION SUMMARY Flow Required: 797.69 gpm Pressure Required: 42.44 psi At: BASE OF RISER "Ci" Factor Used: Overhead: 120 Underground: 100 WATER SUPPLY WATER FLOW TEST PUMP DATA Date: Rated Capacity: Time: At: Static: 65 psi Elevation: Residual: 54.74 psi Flowing: 942.1 gpm Elevation: ft Location: BASE OF RISER Source of Information: CALC PLATE TANK OR RESERVOIR gpm Capacity: gals psi Elevation: ft ft WELL Proof Flow:' gpm COMMODITY STORAGE Commodity: Class: Location: Storage Height: Area: Aisle Width: Storage Method: Solid Pile: % Palletized: % Rack: % RACK STORAGE Single Row O Double Row Multiple Row FLUE SPACING Longitudinal: O Conventional Pallet Slave Pallet Automatic Storage Solid Shelving O Open Encapsulated 0 Nonencapsulated CLEARANCE FROM TOP OF STORAGE TO CEILING in Transverse: in ft in Horizontal Barriers Provided:L ED File: LLOYDS AUTO SPEC. .the Page 1 of 3 Node Node Flow K-factor Elevation Pressure Diameter Length Eric Loss Node Node Flow K-factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity Ttl Length Ttl FL A 0.00 -4.00 44.17 6.340 75.000 0.000 B 0.00 -4.00 44.17 100 T 26.572 0.00 0.00 0.00 101.570 0.00 B 0.00 -4.00 44.17 6.340 7.000 0.000 C 0.00 3.00 41.14 100 E 12.400 0.00 0.00 0.00 19.400 0.00 C 0.00 3.00 41.14 6.340 6.000 0.000 D 0.00 3.00 41.14 100 GV,CV,E 43.401 0.00 0.00 0.00 49.400 0.00 The Flow Dependent Pressure Loss Device in this pipe accounts for 0.00 psi of the total friction loss. D 0.00 3.00 41.14 6.340 7.000 0.000 E 0.00 -4.00 44.17 100 E 12.400 0.00 0.00 0.00 19.400 0.00 E 0.00 -4.00 44.17 6.340 55.000 0.000 F 0.00 -4.00 44.17 100 E 12.400 0.00 0.00 0.00 67.400 0.00 F 0.00 4.00 44.17 6.340 4.000 0.000 1 797.69 Source 0.00 4.44 100 E 12.400 0.00 0.00 0.00 16.400 0.00 1 797.69 Source 0.00 42.44 4.260 15.000 0.021 2 0.00 15.00 35.16 120 ALV • 22.384 • 6.50 297.69 6.70 37.380 0.78 2 0.00 15.00 35.16 4.260 50.000 0.021 3 0.00 15.00 33.84 120 E 13.167 0.00 297.69 6.70 63.170 1.32 3 0.00 15.00 33.84 3.260 20.000 0.077 4 0.00 15.00 31.58 120 E 9.408 0.00 297.69 11.44 29.410 2.26 4 0.00 15.00 31.58 3.314 13.000 0.071 5 0.00 4.00 33.15 120 T,E 32.030 -4.77 297.69 11.07 45.030 3.20 5 0.00 4.00 33.15 3.314 2.000 0.071 6 0.00 4.00 31.25 120 E,BV 24.750 0.00 297.69 • 11.07 26.750 1.90 6 0.00 4.00 31.25 3.314 5.000 0.071 7 0.00 9.00 28.00 120 E 10.191 2.17 297.69 11.07 15.190 1.08 I 09/09/10 "THE" Sprinkler Program 2001 Five Star Fire Protection File: LLOYDS AUTO SPEC..the Page 2 of 3 I Node Node Flow K-factor Elevation Pressure Diameter Length Fric Loss Node Node Flow K-factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity Ttl Length Ttl FL 7 0.00 9.00 28:00 3.314 1.000 0.071 8 0.00 9.00 27.21 120 E 10.191 0.00 297.69 11.07 11.190 0.79 8 0.00 9.00 27.21 2.703 7.500 0.051 9 0.00 9.00 25.88 120 1 18.651 0.00 145.69 8.15 26.150 1.33 9 0.00 9.00 25.88 2.703 8.500 0.014 10 0.00 9.00 25.76 120 0.000 0.00 72.76 4.07 8.500 0.12 8 0.00 9.00 27.21 2.703 1.000 0.055 11 0.00 9.00 26.13 120 T 18.651 0.00 152.00 8.50 19.650 1.08 11 0.00 9.00 26.13 2.703 3.500 0.016 12 0.00 9.00 26.07 120 0.000 0.00 78.71 4.40 3.500 0.06 12 0.00 9.00 26.07 1.380 4.500 0.432 13 0.00 9.00 21.54 120 T 6.000 0.00 78.71 16.88 10.500 4.53 13 0.00 9.00 21.54 1.049 6.000 0.579 14 0.00 15.00 10.25 120 T,2E 9.000 2.60 44.82 16.64 15.000 8.68 14 0.00 15.00 10.25 1.049 5.000 0.145 15 0.00 18.00 8.23 120 0.000 1.30 21.17 7.86 5.000 0.72 11 0.00 9.00 26.13 1.380 1.000 0.378 16 0.00 9.00 23.48 120 T 6.000 0.00 73.29 15.72 7.000 2.65 16 0.00 9.00 23.48 1.380 10.000 0.103 17 0.00 9.00 22.45 120 0.000 0.00 36.23 7.77 10.000 1.03 9 0.00 9.00 25.88 1.380 1.000 0.375 18 0.00 9.00 23.25 120 T 6.000 0.00 72.93 15.64 7.000 2.62 18 0.00 9.00 23.25 1.380 10.000 0.102 19 0.00 9.00 22.23 120 0.000 0.00 36.06 7.73 10.000 1.02 I 09/09/10 "THE" Sprinkler Program 2001 Five Star Fire Protection File: LLOYDS AUTO SPEC..the Node Node Flow K-factor Elevation Pressure Diameter Node Node Flow K-factor Elevation Pressure HWC Fittings Pipe Flow Velocity Length Eric Loss Eqv Length Elev Loss Ttl Length Ttl FL Page 3 of 3 10 0.00 9.00 25.76 1.380 1.000 0.373 20 0.00 9.00 23.14 120 T 6.000 0.00 72.76 . 15.61 7.000 2.61 20 0.00 9.00 23.14 1.380 .10.000 0.101 21 0.00 9.00 22.13 120 0.000 0.00 35.97 7.72 10.000 1.01 13 0.00 9.00 21.54 1.049 2.000 0.345 22 33.89 8.00 8.50 17.95 120 T,2E 9.000 -0.22 33.89 12.58 11.000 3.80 14 0.00 15.00 10.25 1.049 1.500 0.177 23 23.65 8.00 15.00 8.74 120 T,E 7.000 0.00 23.65 8.78 8.500 1.51 15 0.00 18.00 8.23 1.049 1.500 0.145 24 21.17 8.00 18.00 7.00 120 T,E 7.000 0.00 21.17 7.86 8.500 1.23 16 0.00 9.00 23.48 1.049 0.500 0.407 25 37.05 8.00 8.50 21.45 120 T 5.000 -0.22 37.05 13.75 5.500 2.24 17 0.00 9.00 22.45 1.049 . 0.500 0.391 26 36.23 8.00 8.50 20.52 120 T 5.000 -0.22 36.23 13.45 5.500 2.15 18 0.00 9.00 23.25 1.049 0.500 0.404 27 36.87 8.00 8.50 21.25 120 T 5.000 -0.22 36.87 13.69 5.500 2.22 19 0.00 9.00 22.23 1.049 0.500 0.387 28 36.06 8.00 . 8.50 20.32 120 T 5.000 -0.22 36.06 13.39 5.500 2.13 20 0.00 9.00 23.14 1.049 0.500 0.402 29 36.79 8.00 8.50 21.15 120 T 5.000 -0.22 36.79 13.66 5.500 2.21 21 0.00 9.00 22.13 1.049 0.500 0.386 30 35.97 8.00 8.50 20.22 120 T 5.000 -0.22 35.97 13.35 . 5.500 2.12 Units Legend Flow = gpm Velocity = ft/sec Eric Loss = psi/ft Elevation = feet Length, Elev Loss, Pressure = psi Eqv Length, Ttl FL = psi Diameter = inches Ttl Length = feet 09/09/10 "THE" Sprinkler Program 2001 Five Star Fire Protection File: LLOYDS AUTO SPEC. .the Nozzle Type& Reference Location Flow Pipe Fittings in Size & gpm inches Devices Pipe Friction Eqiv. Loss Length psi/ft Page 1 of 3 Req. psi Notes Igth 75.000 Pt 44.17 ftg 26.572 0.000 'Pf 0.00 tot 101.570 Pe 0.00 Igth 7.000 Pt 44.17 ftg 12.400 0.000 Pf 0.00 tot 19.400 Pe 0.00 Igth 6.000 Pt 41.14 FDPLD = ftg 43.401 0.000 Pf 0.00 0.00 tot 49.400 Pe 0.00 Igth 7.000 Pt 41.14 ftg 12.400 0.000 Pf 0.00 tot 19.400 Pe 0.00 Igth 55.000 Pt 44.17 ftg 12.400 0.000 Pf 0.00 tot 67.400 Pe 0.00 Igth 4.000 Pt 44.17 ftg 12.400 0.000 Pf 0.00 tot 16.400 Pe 0.00 Igth 15.000 Pt 35.16 ftg 22.384 0.021 Pf 0.78 tot 37.380 Pe 6.50 Igth 50.000 Pt 33.84 ftg 13.167 0.021 Pf 1.32 tot 63.170 Pe 0.00 Igth 20.000 Pt 31.58 .ftg 9.408 0.077 Pf 2.26 tot 29.410 Pe 0.00 Igth .13.000 Pt 33.15 ftg 32.030 0.071 Pf 3.20 tot 45.030 Pe -4.77 Igth 2.000 Pt 31.25 ftg 24.750 0.071 Pf 1.90 tot 26.750 Pe 0.00 Igth 5.000 Pt 28.00 ftg 10191 0.071 Pf 1.08 tot 15.190 Pe 2.17 A q 0.00 6.340 to Q 0.00 100 T B B q 0.00 6.340 to Q 0.00 100 C C q 0.00 6.340 to Q 0.00 100 GVCV,E D FDPLD D q 0.00 6.340 to Q 0.00 100 E E E q 0.00 6.340 to Q 0.00 100 E F F q 0.00 6.340 to Q 0.00 100 E I Source 2 q 0.00 4.260 to 0 297.69 120 ALV I Source 3 q 0.00 4.260 to 0 297.69 120 E 2 4 q 0.00 3.260 to 0 297.69 120 E 3 5 q 0.00 3.314 to 0 297.69 120 T,E 4 6 q 0.00 3.314 to 0 297.69 120 E, BV 5 7 q 0.00 3.314 to Q 297.69 120 E 6 09/09/10 . . "THE" Sprinkler Program 2001 Five Star Fire Protection File: LLOYDS AUTO SPEC. the Page 2 of 3 Nozzle Flow. Pipe Fittings Pipe Friction Type & in Size & Eqiv. Loss Req. Reference Location gpm inches Devices Length psi/ft psi Notes 8 q 0.00 3.314 Igth 1.000 Pt 27.21 to Q 297.69 120 E .ftg 10.191 0.071 Pf 0.79 7 : tot 11.190 Pe 0.00 9 q 0.00 2.703 Igth 7.500 Pt 25.88 to Q 145.69 120 T ftg 18.651 0.051 Pf 1.33 8 tot 26.150 Pe 0.00 10 q 0.00 2.703 Igth 8.500 Pt 25.76 to Q 72.76 120 ftg 0.000 0.014 Pf 0.12 9 tot 8.500 Pe 0.00 11 q 0.00 2.703 Igth 1.000 Pt 26.13 to Q 152.00 120 1 .ftg 18.651 0.055 Pf 1.08 8 tot 19.650 Pe 0.00 12 q 0.00 2.703 Igth 3.500 Pt 26.07 to Q 78.71 120 ftg 0.000 0.016 Pf 0.06 11 tot 3.500 Pe 0.00 13 q 0.00 1.380 Igth 4.500 Pt 21.54 to Q 78.71 120 T ftg 6.000 0.432 Pf 4.53 12 tot 10.500 Pe 0.00 14 q 0.00 1.049 Igth 6.000 Pt 10.25 to Q 44.82 120 T,2E ftg 9.000 0.579 Pf 8.68 13 tot 15.000 Pe 2.60 15 q 0.00 1.049 Igth 5.000 Pt 8.23 to Q 21.17 120 ftg 0.000 0.145 Pf 0.72 14 tot 5.000 Pe 1.30 16 q 0.00 1.380 Igth 1.000 Pt 23.48 to Q 73.29 120 T ftg 6.000 0.378 Pf 2.65 11 tot 7.000 Pe 0.00 17 q 0.00 1.380 Igth 10.000 Pt 22.45 to Q 36.23 120 . ftg 0.000 0.103 Pf 1.03 16 tot 10.000 Pe 0.00 18 q 0.00 1.380 Igth 1.000 Pt 23.25 to Q 72.93 120 T ftg 6.000 0.375 Pf 2.62 9 tot 7.000 Pe 0.00 19 q 0.00 1.380 Igth 10.000 Pt 22.23 to Q 36.06 120 ftg 0.000 0.102 Pf 1.02 18 tot 10.000 Pe 0.00 09/09/10 "THE" Sprinkler Program 2001 Five Star Fire Protection - File: LLOYDS AUTO SPEC..the Page 3 of 3 Nozzle Flow Pipe Fittings Pipe Friction Type & in Size & Eqiv. Loss Req. Reference Location gpm inches Devices Length psi/ft psi Notes 20 q 0.00 1.380 Igth 1.000 . Pt 23.14 to Q 72.76 120 T ftg 6.000 0.373 Pf 2.61 10 tot 7.000 Pe 0.00 21 q 0.00 1.380 Igth 10.000 Pt 22.13 to Q 35.97 120 ftg 0.000 .0.101 Pf 1.01 20 . tot 10.000 Pe 0.00 22 8.00 q 33.89 1.049 Igth 2.000 Pt 17.95 to Q 33.89 120 T,2E ftg 9.000 0.345 Pt 3.80 13 tot 11.000 Pe -0.22 23 8.00 q 23.65 1.049 Igth 1.500 Pt 8.74 to Q 23.65 120 T,E ftg 7.000 0.177 Pf 1.51 14 tot 8.500 Pe 0.00 24 8.00 q 21.17 1.049 . Igth 1.500 Pt 7.00 to Q 21.17 120 T,E ftg 7.000 0.145 Pf 1.23 15 tot 8.500 Pe 0.00 25 8.00 q 37.05 1.049 Igth 0.500 Pt 21.45 to Q 37.05 120 T ftg 5.000 0.407 Pf 2.24 16 tot 5.500 Pe -0.22 26 8.00 q 36.23 1.049 Igth 0.500 Pt 20.52 to Q 36.23 120 T ftg 5.000 0.391 Pf 2.15 17 tot 5.500 Pe -0.22 27 . 8.00 q 36.87 1.049 Igth 0.500 Pt 21.25 to Q 36.87 120 T ftg 5.000 0.404 Pt 2.22 18 tot 5.500 Pe -0.22 28 8.00 q 36.06 1.049 Igth 0.500 Pt 20.32 to Q 36.06 120 T ftg 5.000 0.387 Pf 2.13 19 tot 5.500 Pe -0.22 29 8.00 q 36.79 1.049 Igth 0.500 . Pt 21.15 to Q 36.79 120 T ftg 5.000 0.402 Pf 2.21 20 . tot 5.500 Pe -0.22 30 8.00 q 35.97 1.049 Igth 0.500 Pt 20.22 to Q 35.97 120 T ftg 5.000 0.386 Pf 2.12 21 . tot 5.500 Pe -0.22 Qt 797.69 . Pt 42.44 I 09/09/10 "THE" Sprinkler Program 2001 Five Star Fire Protection 50 Water Supply vs. Sprinkler Demand 90 - 80 70 60 942 55 298@42 w/ 500 HSA 30 20 10 0 0100 200 300 400 500 600 700 800 900 Flow (gpm) File: LLOYDS AUTO SPEC. .the Page 1 of I Hydraulic Summary WATER SUPPLY INFORMATION: Static (psi): 65.00 Residual (psi): 54.74 © (gpm): 942.10 Hose (gpm): 500.00 System req. (gpm): 797.69 © (psi): 42.44 Supply available: 57.46 psi Safety margin: 15.02 psi Maximum velocity in the system is: Continuity at all nodes satisfied to: Pipe Type Legend Dl = Ductile Iron Class 51 10= Schedule 10 DF = Allied Dyna-Flow/Super Flo 40 = Schedule 40 NOTES: 16.88 ft/sec in the pipe between Nodes: 12 and 13 0.01 gpm Fitting Type Legend T = Tee (flow turned 90 degrees E = 90 degree standard elbow GV =Gate valve CV = Swing check valve ALV =Alarm valve BV = Butterfly valve 09/09/10 "THE' Sprinkler Program 2001 Five Star Fire Protection NAME: BILL ADDRESS: TO ATTENTION: PHONE: - SL:KVICL: OKLflK NO. I J PYRO-COMM SYSTEMS, INC. 15531 Container Lane Huntington Beach, CA 92649 License C-10 #612153 PH.(714) 902-8000 FAX (714) 902-8001 DATE: 7/.'. f-it. IR0. #: ONTA1 SYSTEMjFIRE INTERCOM PAGING SEURflY []OTHER: SERVICE INFORMATION L / .:p (.•,,I; : JOB NAME: , ) (• ADDRESS: (:-,, i-/,j. r4 REPORTED W. PHONE: PROBLEM(S) REPORTED - PROBLEM(s) SPECIAL INSTRUCTIONS DESCRIPTION OF WORK PERFORMED / _., . F •.• • I.''/ •r/ .'.-/ - __•.__i_ ii r r / ,I W c• / .-f I - - !/c--t;f'f( :.•,/- .... -i:-t.,.- .., .J - ••, , ,-.. I MINIMUM SERVICE DATE AMOUNT .' I ./I__, 1 Ii; - F, ADDITIONAL LABOR DATE I HOURS I RATE I AMOUNT DATE COMPLETED: SIGNATUBE: I' lINT NAME: -. /71 •-v . - r 1 INVOICING TO FOLLOW APPROp9S SUBMITTED CAR FIRE PROTECTION TENANT IMPROVEMENT FOR LLOYDS AUTO 1050 AUTO CENTER CT. CARLSBAD, CA 92008 BY FIVE STAR FIRE PROTECTION, INC. 740 E. LAMBERT ROAD #A LA HABRA, CA 90631 PHONE: (562) 690-6500 W.- SPRINKLERS W. ., March 7, 2008 S I NIIKJW*i f\S Sprinkler ha MICROMATIC® AND MicromaticHP® STANDARD RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different fin- ishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page jib. V.! LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2006, 2015, and 2017 NYC Approved: MEA 89-92-E, Volume 12 ABS Certified: Certificate 04-HS407984A-PDA VdS Approved: Certificate G4040096, G4040098, G4060058, G4060059, G4980001, G4980002, G4980005, and G4980007 LPC Approved: Ref. No. 096e/06 and 167a104 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40141, 0786-CPD-40181, 0832-CPD-2001, and S 0832-CPD-2003 ME D Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008, and RINA Certificate No. MED497705C5 NOTE: Other International approval certificates are available upon request. Refer to the Approval Charts on pages 11d-f and Design Criteria on page hf for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: Refer to the Approval Chart Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK023 and VK122 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi http:llwww.vikinggroupinc.com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval C,arts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 10139, 10142, 10170, 10173, 10223, and 12105. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09994, 10189, 10221, and 10222): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Form No. F_100397 Replaces page ha-h, dated October 12, 2007. (Added Dry System note in approval chart for Small Orifice) Sprinkler 11b March 7, 2008 S MICROMATIC® AND MicromaticHP® STANDARD RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09992, 09994, and 10221: Brass UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C 11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12105): Stainless Steel For Teflon® Coated Sørinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-NV, Black Polyester = M-/B, Black Teflon® = N, Wax Coated = C, Wax Over Polyester = V-/W Temperature Suffix (°F/°C): 135°/570 =A, 155°/68" = B. 175°/79° = D. 2000/93" = E, 212°/100° = M, 286°I141° = G, 360°/182° = H, 500°/260" = L, OPEN = Z (Teflon® only). For example, sprinkler VKIO2 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 10139A8 Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: S A. Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers: Part No. 12144W/B' (available since 2003) Wrench for wax coated sprinklers: Part No. 13577W/B** (available since 2006) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A W ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE S For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench - - Protective Sprinkler FLat Cap 9=W=M Figure 1: Standard Sprinkler Wrench 10896W/B Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats. S March 7, 2008 Sprinkler I 1 MICROMATIC® AND MicromaticHP® STANDARD J I FJ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Ordinary 135 OF (57 'C) 100 OF (38 'C) Orange Ordinary 155 OF (68 'C) 100 OF (38 'C) Red Intermediate 175 OF (79 'C) 150 OF (65 'C) Yellow Intermediate 200 OF (93 'C) 150 OF (65 'C) Green Intermediate 212 OF (100 'C) 150 OF (65 'C) Green High 286 OF (141 'C) 225 OF (107 'C) Blue Extra High 360 OF (182 'C) 300 OF (149 'C) Mauve Ultra High' 500 OF (260 'C) 465 OF (240 'C) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester5 for sprinklers with the following temperature ratings: 135 OF (57 °C) Off-White Wax 155 OF (68 'C) Lt. Brown Wax 175 OF (79 'C) Brown Wax 200 OF (93 'C) Brown Wax 212 OF (100 'C) Dk. Brown Wax6 286 OF (141 'C) Dk. Brown Wax6 Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal oper- ating temperatures above 300 OF (149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 'C), response time may be severely retarded. ' The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 11 d-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Wax Over Polyester is unavailable for Sprinklers VK023 and VK122. 6 Wax melting point is 170 OF (76 °C) for 212 OF (100 'C) and 286 OF (141 'C) temperature rated sprinklers. S ~=7 _ -Sprinkler Wrench 12144V/BI6w for L;jz_4 installing coated and/or recessed pendent sprinklers 'L------ with protective caps. 1------ wwA 1/2' ratchet is required (not available from Viking). I Figure 2: Wrench 12144W1B for Coated and/or Recessed Pendent Sprinklers I S S Sprinkler lid March 7, 2008 MICROMATIC® AND MicromaticHP® STANDARD sJII(IF.IG RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com rç a •.•• " :' , Mlcrmatc nd pse Pndt SIrrnkIrs - Sfc(1.bar),WINP.% .. __________ ..• .4;i'.A ,:.M.!n917: . Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to Design Criteria on page 11 g.) Number' NPT BSP U.S. metric2 Inches j mm cULus4 FM NYC1 VdS LPCB I (E I 0 Standard Orifice 10139 1 VKIO2 1/2" 15 mm 5.6 80.6 2-3/16" 56 81, D5, E7, F4 A3, C6, F3 61, 05, E7 B3 B3, 05 G3 12 G3'4'5 10173" 1 VK102 I -- 15 mm 1 5.6 1 80.6 1 2-3/16" 1 56 1 B1, D5, E7, F4 A3, C6, F3 BI, 05, E7 I B3 B3, 05 -- -- Large ________ Orifice 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 BI, D5, E7, F4 84, 06, F4 BI, D5, E7 63 - - — 10142 VK202 3/4" 20 mm 8.0 115.2 2-5/16" 59 BI, D5, E7, F4 64, 06, F4 Bi, D5, E7 B3, D5 G4'2 G4'4 10170 VK202 — 20 mm 80 115.2 2-3/8" 60 Bi, D5, E7 C6, A4 -- - 83,05 G4'2 G4'4 12105 VK202 3/4° 20 mm 8.0 115.2 2-3/16" 56 - - - B3 - B3' - Small Orifice9 1022110 VK003 1/2" 15 mm 28 40.3 2-3/16" 56 1 BI, 05, E7 B4, D6 - -- -- - -- 1022210 VK004 1/2" 15 mm 4.2 60.5 2-1/4" 58 Bi, 05, E7 -- -- -- B3, 05 - -- 10175 VK004 - 10 mm 42 60.5 2-1/4" 58 -- -- -- 83 83, 05 G3'3 G3'4 '5 1018910" VK003 — 15 mm 2.8 40.3 2-3/16" 56 Bi, D5, E7 B4, 06 — -- -- - - Approved Temperature Ratings A - 135 OF (57 °C), 155°F (68 °C), 175°F 79 °C), 200°F (93 °C), 212 OF (100 °C), Approved Finishes pprove mis es 286 OF (141 °C), and 360 OF (182 C) I - Brass, Chrome-Enloy®, White Polyester68, Black Polyester66, and Black Teflon® B - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 "C) 200 OF (93 "C), 286 OF 2- White Polyester0, Black Polyester0, Black Teflon®, Wax-Coated Brass, and Wax °C), OF "C) (141 and 360 (182 over Polyester C - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 3 - Brass, Chrome-Enloy®, White Polyester0, and Black Polyester° 212 OF (100 °C) 4- Brass and Chrome-nloy® D - 135°F (57 °C), 155°F (68 °C), 175 OF (79 °C), and 200 OF (93 °C) 5 - Wax-Coated Brass and Wax Over Polyester0 E - 286 OF (141 °C) 6 - Wax-Coated Brass (corrosion resistant) F - 500 OF (260 "C)8 7 - High Temperature 200 OF (93 °C) Wax Coating (corrosion resistant); maximum G - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 OF (141 °C), and ambient temperature allowed at ceiling = 150 OF (65 °C) 360 "F_(182_°C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metiic K-faor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 OF (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is reduced below 300 OF °C), the time significantly (149 response of the Ultra-High temperature rated sprinkler may be severely retarded. °Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. '°The sprinkler orifice is bushed. "SMkIers 10173 and 10189 are available on special order. ertified, Standard EN 12259-1 EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. ' ertified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40141 and 0786-CPD-40181. 14 G MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1 008. 15 0 MED Certified, RlNA Certificate No. MED497705C5. S March 7, 2008 Sprinkler lie MICROMATIC® AND MicromaticHP® STANDARD 44J I 1(1 h C4; RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 'Y 4' M &viatibf tdI R ne Pen tSphrkk st Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to Design Criteria on page 11g.) Number1 NP T BSP U.S. I metric- Inches I mm cULus4 J FM I NYC' I VdS LPCB I CE'2 I 0 Installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon 10139 VK102 1/2" 15 mm 5.6 80.6 2-3/16' 1 56 BI AZ'° BI B2 B2 C2 10173" VKIO2 - 15 mm 5.6 80.6 2-3/16" 56 B1 A310 - - B2 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 BI 13310 BI - - - -- 10142 VK202 3/4" 20 mm 8.0 115.2 2-5/16" 59 81 BY° BI -- B2 C2 -- 10170 VK202 - 20 mm 8.0 115.2 2-3/8" 60 BI BY° - B2 C2 -- 12105 VK202 3/4" 20 mm 8.0 115.2 2-3/16" 56 -- - - 62 62 -- 102218.9 VK003 1/2" 15mm 2.8 40.3 2-3/16" 56 Bi A38 Bi - -- -- 102228' VK004 1/2" 15 mm 42 60.5 2-1/4" 58 BI - BI - B2 - -- Installed with the Viking Microfast® Model F-I Adjustable Escutcheon 10139 VKIO2 1/2" 15 mm 56 80.6 2-3/16" 56 Bi - 61 D2 B2 - - 10223 VK202 112" 15 mm 8.0 115.2 2-3/8" 60 81 - 81 62 -- - -- 102218-9 VK003 1/2" 15 mm 2.8 40.3 2-3/16" 56 61 - 61 - - - - Approved Temperature Ratings Approved Finishes A - 135 "F (57 "C), 155 "F (68 °C), 175 "F (79 °C), 200 "F (93 °C), and 212 °F - Brass, Chrome-EnloyO, Whit: Polyester5.6, Black Polyester66, and ( Black Teflon B - 135 "F (57 °C), 155 "F (68 "C), 175 °F (79 °C), and 200 °F (93 °C) 2 - Brass. Chrome-Enloy, White Polyester°, and Black Polyester6 C - 155 "F (68 °C), 175 °F (79 °C), and 200 "F (93 °C) 3 - Brass and Chrome-Enloy® 0 - 286 "F (141 "C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metiic K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. o Other colors are available on request with the same Listings and Approvals as the standard colors. 'Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. '°FM Approval of Viking MicromaticP Standard Response Recessed Pendent Sprinklers installed with the Viking Micromatk° Model E-1 or E-2 Recessed Escutcheon is limited to wet systems and preaction systems qualifying as wet systems, for hazard occupancies up to and including Ordinary Hazard, Group II. "Sprinkler 10173 is available on special order. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40181, 0832-CPD-2001, and 0832-CPD-2003. S Sprinkler hf March 7, 2008 MICROMATIC® AND MicromaticHP® STANDARD "4I I IJ fJ M: RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com :,;•! __ _____ ____________________ Sprinkler Thread Size1 Nominal Overall Listings and Approvals3 Base Part I SIN K-Factor Length (Refer also to Design Criteria on page 11g.) Number' NPT BSP J U.S. metric- Inches I mm cULus4 FM NYC VdS LPCB 0 Standard Orifice 09992 VK122 1/2" 15 mm 5.6 80.6 2-1/4" 1 58 Al, 02 -- Small Orifice7 099947.8 VK023 J 1/2° 115 mm J 2.8 40.3 2-1/4" 1 58 Al -- Installed with the Viking _Micromatic® Model E-1 or E-2 Recessed Escutcheon 09992 VK122 1/2" 15 mm 5.6 80.6 2-1/4" 58 Cl - - - - - -- 099947.8 VK023 1/2" 15 mm 1 2.8 40.3 2-1/4" 58 Cl - - -- - - -- Installed with the Viking Microfast® Model F-1 Adjustable Escutcheon 09992 VK122 1/2" 15 mm 5.6 80.6 2-1/4" 58 BI - -- - - - 099947.8 VK023 1/2" 15 mm 1 2.8 1 40.3 2-1/4° 58 BI - - - - - -- Approved Temperature Ratings A - 135 °F (57 "C), 155 °F (68 °C), 175 °F (79 "C), 200 °F (93 °C), 286 °F Approved Finishes B - 135 "F (57 °C), 155 °F68 °C) 175°F (79 "C), 200°F (93 °C), and 286 °F 1 - Brass, Chrome-Enloy, White Polyester58, Black Polyester56, and (141 °C) Black Tefion'15 C - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 2 - Brass and Chrome-Enlo® 0 - 500 "F (260 "C)8 Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically dry calculated pipe systems where piping is corrosion resistant or internally galvanized. 8 The sprinkler orifice is bushed. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 0 March 7, 2008 Sprinkler 119 MICROMATIC® AND MicromaticHP® STANDARD 'i 11(1I1E RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com S cULus Listina Requirements: Micromatic5 and MicromaticHP® Standard Pendent Sprinklers are cULus Listed as indicated in the Approval Charts for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies (exception: small onfice sprinklers are limited to Light Hazard where al- lowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aonroval Requirements: Standard Pendent Sprinklers are FM Approved as indicated in the Approval Charts for installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 0 Wax CoatedJ Pendent Sprinkler *wA 1/2 ratchet Is required (not availabLe Fron Viking). j— Sprinkler drench - / 13577W/Bee For 100 lnstauing wax coated sprinklers Step 1: CareFuLLy slide the wrench sideways around J the sprinkLer deflector. r---- 1 - Step 2' CareFully press the wrench upward and ensure engagement with the sprinkler wrench Flats. Figure 3: Wrench 13577W1B for Wax Coated Sprinklers 1/2" (15 mm)___\ A NPT (58 mm) Pendent Sprinkler VK102 1-3/4" (44.5 mm) Installed with a standard 1/8" surface— mounted escutcheon. Sprinkler 11 h March 7, 2008 MICROMATIC® AND MicromaticHP® STANDARD ,J I IJ 18JJ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" (54 mm) t 11______ F1-1/~2" 2" (38 mm) (51 mm) mum Maximum Installed with a Microfast Model F—i Adjustable Escutcheon S Figure 4: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/8" 2-1/2" (63.5 mm) maximum 2-1/8" (54 mm) (54 mm) 1-3/4" 1-1/8" (28.6 mm) (44.5 mm) Minimum Maximum ~Li t -- Installed with a Micromatic Model E-1 Recessed Escutcheon 2" ty 1-1/8" (28.6 mm) (51 mm) Minimum Maximum _________ _900190- Installed with a Model E-2 Thread—on Recessed Escutcheon Figure 5: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons S Form No. F_100397 Replaces page ha-h, dated October 12, 2007. (Added Dry System note in approval chart for Small Orifice) PIPE/FITTINGS 0- ., Dyna-FI$i® High Strength 11 Steel Pipe The original high-strength 110twali srIn ler pipe with hydraulics superior to Scheddle-10. iTHTTh'iii UPS Nominal I.D. WI. WI. (1120 Flllad) Pcs/ Wlilift (21') WI/lift(241) Wt/Ll (25' In; mm In: mm Lbgft; Kg/ni Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lb; Kg 1.191 0830 1.31 91 1,586 1,812 1,888 25. 30.3 1.2 1.95 91 719 822 á56 1'A' 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 7.33 1W 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 13 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 &83 2W 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 02 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 29 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 :6.7 16.16 19 809 925 963 Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic i capabilities and.is recognized as the: most popular alternative to Schedule- 10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to I larger than Schedule-40 and up to 7'YO larger than Schedule-ID, Dyna-Flow pipe hydraulics are exceptional. arger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potentiafor job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installaticn. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter i coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Specifications Approvals !Dyna-FlowiSüper Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Dyna-FlowlSuper Flo is IJL/ULC Listed for use with roll grooved, plain-end !.couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for: roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- ,Flow/Supee Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Additional Benefits Lightweight and easy to install, .. resulting in more efficient use ofyour freight and labor dollars. Provides stability needed to comply with standard hanger spacing ,. (15 ft O.C.) per NFPA. Available in Standard lengths for'..your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as wc11.as easy roll grooving and end prepaation. Available in Factory roll groóved'torm for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and atts as aO. excellent primer for custom pair applications. 7. 7 tqcc/Flow Control c) dlid TUBE & CONDUIT 16100 S. Lathrop- Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 2525 N. 27th Ave. Phoenix, AZ 85009 Customer Serlce: (800) 882-5543 Fax 708-3391806 S2-3 W" DynawT Full Line Sch Dyna-Thread' offers the o Replacement ncy 4 Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe reprscnts In engineering advancement for the sprinkler pipe industry. It combines the -safety and longevity of traditional Sch4O pie with qLIlity and suerior hydraulic adv a n t a g e s . a. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 givin it superior hydraulics. And, when used '!' combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM far fire sprinkler applications. The life expectancy of Dyna-Threid and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates sindoth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and: easy paint application. ®<S>' Listed Approved Listed With its increased strength and lighter I weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. jCorrosion Resistance Ratio (CRR) is a IUL (Underivtiters Laboratory) term for the estimated life expectancy of it pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the 'eakest point of the pipe length. Dyna- rhread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of .00. The internal surface of all black Allied \ibc & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Jorrnula, "ABF". In scientific laboratory test, ABS prayed to have superior resistance to microbial colonization of Ripe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System i first installed. More wall thickness at the thread (CRRl .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with' NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread ii UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable fdi all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (1120 Filled) :PCSI Wt/Llfl (21') WIMN (24') WUUN (25' In; mm In; mm LbslFt; Kg/rn Lbs/FC Kg/rn Lift Lbs: Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 2321 25 27.4 2.0 :2.60 70 887 1013 105 1'/i' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 t3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 251! 40 41.6 3.4 4.79 . 44 959 1097 114, 2.104 3.050 4.57 : 30 1921 2196 228 50 . 53.4 4.5 680 30 871 996 103 S t4C0/F/ow Contral C;) culled TUBE & CONDUIT 16100 S. Lathtop ' Harvey, IL 60426 Customer Service: 11350 Norcom Rd. 'Philadelphia, PA 19154 (800) 8825543 2525 N. 27 th Ave. Phoenix. AZ 85009 Fax 708-339-1806 ,. S3 -3 \ C D FITTINGS L 7(IN ITEM 1111 ME MAX. DIMENSIONS WEIGHT CODE WORKING EACH ) S. P.S.I. A PIECE !T 0990033 500 1.50 1.50 0,62 1 11/4 0890044 500 1.75 1.75 1 0.90 1112 0990055 500 1.94 1.94 1.20 2•. 0390066 500 2.25 2.25 1.85 NOTE: Pleaso corisull the standard thmua information in this catalog. D.I. THREADED FITTINGS. OkU~V ~.~F >M LISTED LISTED ' APIROVED I '111$ II!1W.k' DIMENSIONS A 8 WORKING j WEIGHT EACH PIECE NOMINAL SIZE (INCH) ITEM CODE MAX. :P.S.I. 1 1 114 1)1333 DT444 .. 00 . 500 1 12.. 1.75 1.50 1.75 - 0.85 1.22 1 1/2 D1555 I 500 1.94 1.94 1.55 2 D1666 I 500 2.25 1 2.25 1 2.45 NO I u: Pioar,o consult the standard threui information in this catzitog. ii---.-. • I------ [I I 7.OMI NAL ITEM MAX. WEIGHT CODE WORKING! EACH I,' P.S.I. A ! B PIECE lxl/2 0890031 50041261136 044 ..JLt... 2 0922 ..9Q._.J----'L.JJ: ..L 1 114x1/2 D890041 500 1.34 , 1.53 0.64 I 110314 0890042 500 i 1.45 1.62 0.72 1 114x1 0B00043 500 150 1.67 0.75 1 1/20 DB90053 500 1.65 1.80 0.92 I 1/2x1 1/4 1)890054 500 1.82 1.08 1.08 2x112 DB90061 500 1.49 1.88 1.08 2x3/4 0890062 500 1.60 1.97 1.24 2x1 1)890063 I 500 1.73 2.02 1.40 20 114 0890064 1 500 1.90 1 2.10 1.52 2x1 112 980.5 ,L.p0 L.1L. .&L. .J:!...,. NOTE: Please Consult the etaiirJiid Intend in,ormailiiimm in this calnl(icj r:1 -• t\:\ ..- U . .----- --1 DUCTILE I RON COUPLING NOMINAL ITEM MAX. DIMENSIONS WEIGHT I SIZE CODE WORKING EACH 'NCH) I P.S.I. A PIECE 1___ 1.67 11/4 0CL044 500 1.93 0.57 .....IJL?_ DCL055 _0 .----------2.iJ.975 . 2 DCL066 500 2.53 1.15 NOTE: Pluae cunnuh thri standard lhrat inteiuruation iii this; (:nU3lOiJ. IiIULiI!4I: sI:1*Z.I.1uJr.Juire NOMINAL ITEM MAX. DIMENSION..... WEIGHT SIZE CODE WRKING EACH (INCH) S P.S.I. A PIECE lx1/2 0RC03-----i--o---• 1.6 14 L 0.39 _j!P__J, 1.69 _ NOTE: Please colisult tin, r.lanclard inroad information im. this catalog. DUCTILE IRON 45 DEG. ELBOW NOMINAL ITEM it DIMENSIONS I 4AX. . . GHT ODE WORKING 11 fEACH (INCH) FfS.I. A BCE 1 61345033 500 1 1.12 1.12 0.46 1 114 13645044 !OO : 1.29 1.29 0.73 1112 D845055 goo 1.43 1.43 0.92 . _100 6 1.68 5O NOTE: Please consult time stendluci thrm*i information in this catalog. Ob re Protection Equipment Submittal Shoot document is a submittal sheet covering grooved Submitted By; fire protection piping products. All checked boxes are intended to be Date Submitted: used on thö ____________________________________ project by p.vject name Approved By: contractor. cwwactor name Date Approved: Manufactured by; Central Sprink, mo., a Subsidiary of Central Sprinkler Co. 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Grooved Couplings Grooved Fittings Q 705 Coupling AK> El 706 Grooved Reducing 0 Coupling J 811901 Elbow 0 812 900 Red. Elbow 81345Elbow 814 Tee 815 Reducing Tee Q 816 Reducing -. Coupling 817Cross 722 Grooved Outlet C3 772 Coupling 41 Flange 0 o 818 Coupling J 820 Cap [J 825 Extension Piece 827 Hex Bushing Q 830 Brass Seal Union 0 719 Plug 11Q&210 90 Elbow 45 Elbow 111&201 Q 120&219 Tee 121 Reducing Teern Grooved Cl 150 Reducer 160&260 Cap C] 750 Adacap Welded Outlets Q 7013001b Welded ii Outlet (threaded) Q 702 300 lb Welded Outlet (grooved) S 707 Coupling 720 Threaded Threaded Outlet 0 1^0 Ductile Iron Threaded Fittings No. 18.0.0 Listing - ..ccncral $prinlc products are UL and ULC Listed and/or FM Approved for the pressure ratings shown for use in fire protection systems (auto- Mat1C sprinkler, open sprinkler and standpipe) and connections to such systems. The charts were developed from the latest listings and approval "ta available as the time of publication. Listings are subject to changes and additions by the approval bodies. For dry pipe systems or freezer systems. - eTri.&al freezer gaskets for use with Central Sprink 705.707 and 772 couplings. Follow installation instructions provided in individual data sheets. Grooved Couplings F Pipe ISchodula - 'Size (ioias) r.ra I Rated P,sauro OnW US. ULC PM 1 10.40 1%.4 500 500 1 500 rio 5 300 300 r500 136 400 400 (SOO 40 40 [ 10 300 300 1500 400 400j500 L 10 B 300 300 1500 S Notes: BLT' Black Light Wall Threadable Listed/Approved steel sprinkler pipe manufactured by Ametican Tube. DF = Dyna-Flow, Listed/Approved steel sprinkler pipe manufactured by American Tube. DL Dyna.Light Sch. S Listed/Approved steel sprinkler pipe manufactured by American Tube. ( DT = Dyna-Thread Listed/Approved steel sprinkler pipe manufactured by American Tube. . SF = Super-Flow Listed/Approved steel sprinkler pipe manufactured by Allied Tube & Conduit. SL. = Listed/Approved steel sprinkler pipe manufactured by Western Tube & Conduit. HF = Hi Flo Listed/Approved Hi-Plo steel sprinkler pipe manufactured by Western Tube & Conduit. XL = Extra Light Weight Listed/Approved steel sprinkler pipe manufaciuted by Allied Tube & Conduit. TL. = TI. tistedlApproved steel sprinkler pipe manufac t u r e d b y Central Sprinkler Company. Xl. 115-2 300 = - - - Model 70G R I 10.40 1% 300 300 300 214a2 300 300 800 34 300 300 500 3415 300 300 300 • 44.4x3 300 300 400 1173 SrI 300 175 175 8z4 300 175 115 6$.3x6 300 175 OF 2X IN 300 300 300 21.44 300 300 300 34 300 300 300 3214 300 300 300 4X22%.3300 300 300 Dl. 391W 175 175 - )1eLT t%300 300 - OI1% 300 300 300 SmZ 215 ,300 300 300 4X2215.3 300 300 300 OF Th 300 300 300 34.215 300 300 330 44. 215.3 300 300 300 54. 2cltt 300 300 - 11. 2x115 Model 707 300 Coupling 300 - 10.40 115 1000 10.40 2 900 900 1000 10 21.4 Y 700 -SN- W 2% 800 300 800 10 3 1M 706 -aw 40 3 . 800 800 -615- 10 4 400 400 500 40 - 4 700 .700 500 10 S 400 500 500 10 5 600 600 500 II) 6 400 400 400 40 6 600 400 400• 10 8 400 400 300 40 8 500 500 300 10 to 500 300 1 400 40 10 500 500 1 400 10 12 500 530 400 30 12 - 350 - 40 12 500 350 400 Welded Outlets Pipe Pipe louttet ichedui Size Size Rated Proazuro US. JuI.c I PM (niches) (nlchs5)J 10.40 1.4 14-4 300 300 300 I-S 14.4 300 300 - 1.5 %.% 300 - 330 115-8 1 300 - 300 2.8 11.1. 115 300 300 21rB 2 300 - 300 3.3 2% 300 - 300 4.8 3 330 - 300 54 1 4 300 1 •- 1 300 OF 1.4 1 %4 330 330 1 330 Dl. 1.2 15-2 175 175 115 DT 1-2 15-2 300 300 300 BLT 1-2 14-2 300 300 - TI. 1-2 315.2 300 300 - L2t5.3, 300 300 300 4.5.8 300 300 300 2% 300 300 300 3 300 300 300 4 300 300 300 a 6 300 300 - 2-4 300 300 300 2 175 175 175 2 300 300 - 2-3 330 9 300 300 - J I I1 I •J I iW - 10.40 13k*4'41 3z1%.2 300 F!'T3I.1!LtU 300 300 451'4.$300 300 300 441.4. 300 300 300 54.3 300 300 300 6x4 175 300 300 8215-3 300 300 - 8x4 300 1 250 - OF 3r114.2 300 300 300 4x115.2 250 300 300 4214. 3 250 250 300 HF 3r1142 300 - 300 4*114-3 300 - 300 SF 3*114.2 300 300 300 4*115.2% 300 300 300 48 300 250 300 0- HANGERS S , 01(, . ~ co CORONA CA r ç • 9)737-5599 ® ® Fig. 2 WON - Adjustable Band Hanger Without Swivel Nut Fig. 2F WON - Felt Lined Band Hanger Without Swivel Nut Size Range - (Fig. 2WON) 1/2 thru 8 inch pipe. (Fig. 2F WON) 1/2 thru 8 inch copper tube. Material - Pre-Galvanized Steel. Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig.220 shield. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171E, type 7, and Manufacturers Standardization Society SP-69,type 7,3/4 thru 6 inch Finish - Pre-Galvanized. Note—Available in Stainless Steel materials. Order By- Figure number and pipe size. Fig. 2WON Fig. 2F WON PIPE ROD B C D MAX. REC. APPROX. SIZE SIZE A LOAD LBS. WTJ100 1/2 3/8 2-5/8 2-1/8 1-1/4 400 14 3/4 3/8 2-518 2 1 400 14 1 3/8 2-718 2-1/8 1 400 16 1-1/4 3/8 3-3/8 2-1/2 1-1/4 400 17 1-1/2 3/8 3-1/2 2-1/2 1 400 18 2 3/8 3-3/4 2-1/2 7/8 400 20 2-1/2 1/2* 5 3-1/2 1-1/2 600 27 3 1/2k 5-1/2 3-5/8 1-1/4 600 40 3-1/2 1/2* 6-3/4 4-5/8 2 600 48 4 518* 6-3/4 4-3/8 1-1/2 1000 53 5 5/8**8-1/2 5-5/8 2-1/8 1250 91 6 . 3/4** 9-1/4 5-7/8 1-5/8 1250 99 8 3/4** 12-1/4 7-7/8 2-5/8 1250 120 *3/8U nut is used when NFPA rod sizing is requested. **1/2u nut is used when NFPA rod sizing is requested. 5I24OO1 -27- Fig. 2WON - Adjustable Band Hanger w/o Swivel Nut 000 Fig. 2FWON - Felt Lined Band Hanger w/o Swivel Nut Size Range - (Fig. 2WON) Size 1/2" thru 8° pipe. (Fig. 2F WON) 1/2" thru 8" copper tube Material - Pre-Galvanized Steel Function - Recommended for the suspension of non- insulated pipe or insulated pipe with Fig. 220 shield. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171 E, Type 7, and Manufacturers Standardization Society SP-69, Type 7, 3/4" thru 6". Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number and pipe size Fig. 2F WON Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size A B C 0 Load Lbs. W1tJ100 1/2 3/8 2/ 214, 1'/4 400 14 3/4 3/8 22/. 2 1 400 14 1 3/8 2/ 21/ 1 400 16 1I 3/8 33/i 21/ 11/4 400 17 I'll 3/8 31/ 21!2 1 400 18 2 3/8 33/4 2'!, 7/8 400 20 2'!, 1/2" 5 3112 11/2 600 27 3 1/2" 51/2 35/s 11/ 600 40 31!, 1/2" 6 3 /4 454 2 600 48 4 5/8" 6'/ 4'/ 11h 1000 53 5 5/8"" 8V, 55/i 2'4 1250 91 6 3/4"" 91/ 57 1/. 1250 99 8 3/4" 121I 7'!. 2/. 1250 120 * 3/8" nut is used when NFPA rod sizing is requested. 1/2" nut is used when NFPA rod sizing is requested. OtficeiMarndacturina Facility • 1375 Ssmnqnn Ave • r,nna M Q7R7Q • Ph- oci 117 cc • r. oi ,,, n,In uuuucu uuuinent Page 1 of 1 S HOME ABOUT LITERATURE TECHNICAL TRAINING WHAT'S NEW search Sammys® for Wood - VERTICAL Known as The Original Sammy Super Screw®, vertical Sammys for wood pro' offer cost-effective time savings. Unlike traditional methods of overhead atta. drilling into dimensional lumber and composite wood joists. UL listings and Ft METAL FASTENING Available in a wide range of fastener lengths for /e", 1/2", and M10 thread • SUSPENDED ANCHORING F fi FEATURES FLASHINGS II S No pre-drilling required. li • HOLLOW WALL • Structural attachment and rod and aL. I I • Quick to install using the appropria WALL SYSTEMS '- ...._.J iSV cordless drill/driver. Reduces installation cost. WOOD DECK . Made in the U.S.A. MASONRY ç— a oHS (SVA \ NEW CATA ii AVAILABL _____----- -• ____ ____ MODELS 1 INSTALLATION STEP] INSTALLATION TOOLS] APPLICATIONS Download our new catalog ____ HERE! . VERTICAL APPLICATION - WOOD SUBSTRATE ROD PART NO. MODEL SCREW SIZE DESCRIPTION Irk WOOD 1/4' 8002957 GST 100 1/4 x 1" WOOD 1/4' 8003957 GST 200 1/4 x 2' WOOD 1/4" 8004957 GST 300 1/4 x 3' WOOD 3/8" 8006957 GST .75 1/4 x 3/4" http://sammysuperscrew.comlsaswoocivertjcal.shtmi 9/21/2010 S VrA1.tAUS5 - 1-langers, ?lpe Page 1 of VFXT.EX5098 Hangers, Pipe Page Bottom Hangers, Pipe See General Information for Hangers. Pioe 1TW BUILDEX 1349 W BRYN MAWR AVE ITASCA, IL 60143 USA Pipe hangers For Installation into Steel: EX5098 Model Min Steel Thkns In. Rod Size, in. NPS* Comments SWDR 0.037 3/8 4 Self-drilling anchors for horizontal Installation into steel SWDR 516 0.037 3/8 4 Self-drilling anchors for horizontal installation Into steel DS1R 1" 0.035 3/8 4 Self-drilling anchors for vertical installation into steel DSTR 1- 1/2" 0.035 3/8 4 Self-drilling anchors for vertical Installation into steel DST516 0.188 3/8 4 Self-drilling anchors for vertical installation into steel DSTR516 0.037 3/8 4 Self-drilling anchors for vertical Installation into steel SH-DSTR-1 0.035 3/8 4 Self-drilling anchors for vertical installation or up to 17 degrees from vertical into steel SH-DSTR- i-SS 0.035 3/8 4 Self-drilling anchors for vertical installationor up to 17 degrees from vertical Into steel TEK-50 0.250 3/8 4 Self-drilling anchors for vertical installation into steel X-Press 20 22 gauge 3/8 2-1/2 Threaded anchors for vertical installation into steel, steel prior to pouring of structural concrete, and steel following pouring of lightweight concrete (not greater than 35 PCF) X-Press 35 16 gauge 3/8 4 Threaded anchors for vertical installation into steel, steel prior to pouring of structural concrete, and steel following pouring of lightweight concrete (not greater than 35 PCF) SWXP 16 gauge 3/8 3-1/2 Threaded anchor for horizontal installation into steel SXP 20 22 gauge 3/8 2 Threaded anchor for Installation into steel deck that is horizontal or up to 45 degrees from horizontal SXP 35 16 gauge 3/8 3-1/2 Threaded anchor for Installation into steel deck that is horizontal or up to 90 degress from horizontal SH TEK 50 0.125 3/8 2-1/2 Threaded anchor for installation Into steel bar joist that is up to 70 degrees from horizontal SH TEK 50 0.125 1 3/8 4 1 Threaded anchor for installation into steel bar joist that is horizontal rlallabon into Wood: Model Min Wood Thkns In. Rod Size, in. NPS* Comments SW625 380 1-1/2 3/8 4 Self-threading anchor for horizontal installation Into the side of a wood timber or joist http://database.ul.coni/cgi-binfXYV/template/LISEXT/1FRAME/showpage.html?name=v... 9/21/2010 For In I'-L-1 VFX1-.L)Ca19 - Hangers, Pipe Page 2 of 3 SWG20 1-1/2 3/8 3 Self-threading anchor for horizontal Installation into the side of a wood timber or joist SWG20-SS 1-1/2 3/8 3-1/2 1 2-1/2 Self-threading anchor for horizontal installation into the side of a wood timber or joist SWG20 1-1/2 3/8 Self-threading anchor for horizontal installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size SWG20-SS 1-1/2 3/8 2-1/2 Self-threading anchor for horizontal Installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size SWG25-380 1-1/2 3/8 3-1/2 Self-threadIng anchor for horizontal Installation Into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size GST 25-380 1-1/2 3/8 4 Self-threading anchor for vertical Installation into the bottom of a wood timber or joist GST 30 1-1/2 3/8 4 Self-threading anchor for vertical Installation Into the bottom of a wood timber or joist GST 30-SS 1-1/2 3/8 4 Self-threading anchor for vertical installation Into the bottom of a wood timber or joist SH-GST30 1-1/2 3/8 4 Self-threading anchor for vertical Installation into the bottom of a wood timber or joist SH-GST30- SS 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 20 1-1/2 3/8 2-1/2 Self-threading anchor for vertical Installation into the bottom of a wood timber or Joist GST 20-SS 1-1/2 3/8 2-1/2 Self-threading anchor for vertical Installation into the bottom of a wood timber or joist SH-GST20 1-1/2 3/8 3 Self-threading anchor for vertical Installation into the bottom of a wood timber or joist SH-GST20- 55 1-1/2 3/8 3 Self-threading anchor for vertical installation Into the bottom of a wood timber or joist GST 25-380 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size GST 20 1-1/2 3/8 2-1/2 Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size GST 20-SS 1-1/2 3/8 2-1/2 Self-threading anchor for vertical Installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size SH-GST/ ST 20 1-1/2 3/8 4 Threaded anchor for Installation into wood, 1.5 in. nominal thickness that Is horizontal SH-GST/ CST 20 1-1/2 3/8 2-1/2 - Threaded anchor for installation into wood, 1.5 In. nominal thickness that Is up to 45 degrees from horizontal For Installation Into web joists: Hanger Rod Model Type size, MPS Comments In HD38UBC Truss 3/8 4 Intended for installation onto minimum 2° x 2° x 3/16" steel web joist spaced 1/2°- Bracket 1" apart HD12UBC Truss 1/2 8 Intended for installation onto minimum 2" x 2° x 3/16" steel web joist spaced 5/8°- Bracket 1" apart I1D38UTC Truss 3/8 4 Intended for Installation onto minimum 2° x 2" x 3/16° steel web joist spaced 1/2°- Bracket 1" apart HD12UTC Truss 1/2 8 Intended for installation onto minimum 2° x 2° x 3/16" steel web joist spaced 5/8"- Bracket 1" apart HD388C Truss 3/8 4 Intended for Installation onto minimum 2° x 2° x 3/16" steel web joist spaced 1/2°- Bracket 1" apart HD12BC Truss 1/2 8 Intended for Installation onto minimum 2" x 2" x 3/16" steel web joist spaced 1/2"- Bracket 1" apart 11D38TC Truss 3/8 4 Intended for installation onto minimum 2" x 2° x 3/16" steel web joist spaced 1/2°- Bracket 1" apart HD12TC Truss 1/2 8 Intended for Installation onto minimum 2" x 2° x 3/16° steel web joist spaced 1/2"- Bracket 1" apart HD38 Truss 3/8 4 Intended for Installation onto minimum 2" x 2° x 3/16" steel web joist spaced 1/2"- NWZP Bracket 1° apart H012 Truss 1/2 8 Intended for Installation onto minimum 2" x 2" x 3/16" steel web joist spaced 1/2"- http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?nameV... 9/21/2010 VFA1JA)U9 - Hangers, Pipe Page 3 of 3 NWZP Bracket 1" apart HD Truss-T Truss Bracket 1/2 8 1 Intended for installation onto minimum 1-3/4 in. x 1-3/4 x .2 in steel web joist spaced 1/2 to 1 in. apart * NPS = Nominal pipe size Trademark and/or Tradename: "Truss-T Hanger" Last Updated on 2010-03-12 questions? Print this page Notice of Disclaimer Page Top Copyright © 2010 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so Identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under ULs Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (flies) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice In the following format: "Copyright © 2010 Underwriters Laboratories Inc.®" An independent organization working for a safer world with integrity, precision and knowledge. http://database.uLcom/cgi-binlXYV/temp1atefLISEXT/1FRAME/showpage.html?nazneV... 9/21/2010 Untitled Document Page 1 of 2 HOME ABOUT LITERATURE TECHNICAL TRAINING WHAT'S NEW MADE IN U.S.A. GREEN search Sammys® for Wood - VERTICAL *XsL Known as The Original Sammy Super Screw, vertical Samriays for wood provide reduced installation costs and offer cost-effective time savings. Unlike traditional methods of overhead attachments, they require no pre- drilling into dimensional lumber and composite wood joists. UL listings and EM approvals are available. METAL FASTENING Available in a wide range of fastener lengths for ¼", %". ½", and 1410 threaded rod. SUSPENDED ANCHORING if FEATURES FLASHINGS • No pre-drilling required. HOLLOW WALL II • Structural attachment and rod anchor combined. Quick to install using the appropriate Sammy Nut Driver with an WALL SYSTEMS L........... .......J 18V cordless drill/driver. Reduces Installation cost. WOOD DECK S Made In the U.S.A. MASONRY S 1T1IAPPUCATIO ILJIL. STEP : Insert the appropriate nut driver into a )f" or 'h' portable drill. STEP 2: Insert the SAMMYS into the a 14 (black) nut driver. Drill should be in a vertical position. STEP 3: Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. STEP 4: The SAMMYS is now ready to receive 'I.,", %", ½" or metric all thread rod, bolt stock. (The 1/2" requires the Z 145W red nut driver) Important Note: Warranty requires the use of the appropriate Sammy Nut Driver for installations. S http:llsammysuperscrew.com/sas_woodvertical.shtml 9/21/2010 Untitled Document Page 2 of 2 CAREERS I PRESS ROOM I SITE MAP I CONTACT I TRADE SHOWS I WARRANTY I PRIVACY POLICY , 2010 ITW 9oiIde, and IlioiniIooI Works, Inc. webmaster@itwbuildex.cOm a J^. Ir. a i j-' S J 2.14x1: Fig. 58 -Threaded Side Beam Bracket Size Range - 3/8" rod, pipe sizes 1/2" thru 4" Material - Carbon Steel Function - Practical and economical bracket used to support piping from wood, concrete or steel beams. Features - Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2" thru 2" pipe requires 3/8" fastener, 21/2" thru 4" pipe requires 1/2" fastener.* Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note - Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish - Plain Note - Available in Electra-Galvanized finish. Order By - Figure number and finish Dimensions 'Weights Pipe Size Qty. Fastener Type Material 2 2 #16 x 2 Drive Screws Wood 2 1 3/8 Lag Bolt Wood 21/2 -4 1 1/2 Lag Bolt Wood 3'I2 2 1/4 x V12 Lag Bolt Wood 4 2 1/4 x 2 Lag Bolts* Wood 112 4 2 1/4 x I tek screws 14 gauge 4 2 1/4 x I tek screws 16 gauge No pre-drilling required Dimensions • Weights Pipe Rod Max. Rec. Approx. Size Size A B C Load Lbs. WtJ100 1/2 thru 4 3/8 2/4 11/, 11/ 300 14 a_~ 2- 1IzLa9.clls O4O:PI84ñlfl9) tip 404 lnth Pipe P4WNFPA I -Lag. oft U; To 4:lnch Pipe %6x2 )r_~ flffirpiMmifrhu'nn F;hI,. • 1174 á,.. • r,.,nn. ra o,00 . Dh =I 171 CC - C-. Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8° hanger rod 2j Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. i•t•• Finish - Electro Galvanized Note - Available in HOG finish or Stainless Steel materials. ) Order By - Figure number Ni Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8° thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 S 7/8 1 3770 3360 169 4960 4420 222 11i4 8000 7140 360 11/2 11630 10370 510 - r..;t;,,. • ii7c • r_ rA o,a,n . .. nc, ,,, r.... TOLSTRUT A-12 CHANNEL TdR o TOLCOI, abrand of N9C' CORONA. CA (909)737-5599 lyr 15/8" 3/8..f.7I81Lj 15/8" X-.- 9132 .925 rib I- I L CIOL X 15/8" .700 f A-12 15/8" ELEMENTS OF SECTION A-12A CHANNEL AREA OF AXIS X-X AXIS Y-Y CATALOG WEIGHT LBSIFT. SECTION I (IN.) S (IN.) R (IN.) I (IN.) S (IN?) R (IN.) NUMBER SQ.IN. A-12 1.89 .583 .188 .203 .581 .257 .316 .680 A-12A 3.78 1.166 .920 .566 .910 .514 .632 .680 = Moment of Inertia S = Section modulus R = Radius of gyration BEAM AND COLUMN LOADS DATA CHANNEL BEAM SPAN UNIFORM LOAD DEFLECTION UNIFORM LOAD (LBS.) MAXIMUM CATALOG OR UNBRACED AT STRESS OF AT STRESS OF WHEN MAXIMUM ALLOWABLE LOAD NUMBER COLUMN HEIGHT 25,000 PSI (LBS.) 25,000 PSI (IN.) DEFLECTION = OF COLUMN (LBS.) A.12 is, 2213 .031 2213 11300 24" 1680 .055 1680 9700 30" 1340 .086 1340 8850 36" 1125 .125 1125 8600 42" 950 .168 950 7550 48" 855 .225 757 6720 60" 690 .356 484 5800 72" 555 .594 336 4970 84" 490 .693 247 4250 96" 433 .915 189 3500 120" 335 1.382 121 2100 A-12A 18" 6530 .018 6530 24340 24" 4895 .033 4895 21800 30" 3800 .050 3800 21500 36" 3100 .070 3100 21000 42" 2700 .097 2700 20600 48" 2300 .124 2300 19900 60" 1930 .203 1930 17950 72" 1560 .284 1560 15940 84" 1360 .393 1210 14750 . 96" 1200 .438 926 12650 120" 953 .680 593 8000 Beam loads: Loads listed are uniformly distributed, for loads concentrated at center of span multiply uniform load at table by .5 and multiply the deflection by .8. When deflection is not a factor use stress of 25.000 psi. When deflection is a factor use deflection of J4 Column loads: Loads listed are for unbraced heights as listed. Modulus of elasticity = 29,000.000 psi. Slotted or punched channel reduce load rating 10%. 6 S ripe uamps Page 1 of . , 11, , t") SIiIFIjj I Po Cain Pipe Clamps O.D. Tubing Clamps O.D. Weight Metal Design Load SafetyFactor Size IbaJ100 Gauge 114 8 16 400 318 8 16 400 112 9 16 400 518 9 16 400 314 11 16 400 718 (RIGD 112) 15 16 400 I (RIGO 3/4) 16 14 600 1118 18 14 600 1114 16 14 600 1318(RIGDI) 17 14 600 1112 18 14 600 1518(RIGDI 19 14 600 114) 13/4 28 12 800 17/8(RIGDI 28 12 800 1/2) 2 31 12 800 2118 31 12 800 2114 33 12 800 2318(RIGD2) 34 12 800 21/2 35 12 800 25/8 35 12 800 2314 38 12 800 27/8(RIGD2 40 12 800 1/2) 3 39 12 800 3118 39 12 800 31/4 45 12 800 33/8 46 12 800 3112 (RIGO 3) 47 12 1000 35/8 54 11 1000 33/4 54 11 1000 37/8 60 11 1000 4(RIGD3I/2) 62 11 1000 41/8 64 11 1000 41/4 64 11 1000 43/8 65 11 1000 41/2(Rlgid4) 66 11 1000 45/8 64 11 1000 43/4 72 11 1000 47/8 73 11 1000 5 68 11 1000 51/8 68 11 1000 51/4 77 11 1000 53/8 79 11 1000 51/2 79 10 1000 55/8(RIGD5) Be 10 1000 53/4 90 10 1000 57/8 92 10 1000 O.D. Tubing Clamps Weight Metal Design Load at O.D. Size lbs/I® Gauge Safety Factor of 5 6 87 10 1000 61/8 S 96 10 1000 61/4 98 10 1000 63/8 96 10 1000 S http://www.tolco.com/strut-fittings/pipe-clamps/pipe-clamps2.asp 9/21/2010 Pipe Clamps Page 2 of 2 6112 100 10 1000 6518(RIGD6) 102 10 1000 6314 S 96 10 1000 6718 100 10 1000 7 108 10 1000 7118 110 10 1000 7114 III 10 1000 7318 113 10 1000 7112 104 10 1000 7518 110 10 1000 7314 111 10 1000 7718 120 10 1000 8 122 10 1000 8118 124 10 1000 8114 125 10 1000 83/8 114 10 1000 81/2 128 10 1000 8518(RIGD8) 123 10 1000 8314 122 10 1000 8718 119 10 1000 9 118 10 1000 91/2 126 10 1000 9518 129 10 1000 10 135 10 1000 10314(RIGDIO) 140 10 1000 11 145 10 1000 11518 151 10 1000 12 156 10 1000 12314(RIGO12) 153 10 1000 Laiger and intermediate sizes available, consult factafy. Page 1 S I,+t..iI..,..,..r f,j, .4++;I..;.... fl V1 I'A1 A (~ P.-,, T P qt, Pe IPLCQ . _ I Slid Fittflcis I PpoCIipS Pipe Clamps To secure steel, copper, conduit & various plastic tubing to strut. Pipe Clamps for Rigid Conduit Catalog Weight Metal Design Load at Number O.D. lbsJ100 Gauge Safety Factor of S RIGD 12 .840 11 16 400 RIGD 314 1.050 15 14 600 RIGDI 1.315 17 14 600 RIGD 1114 1.660 19 14 600 RIGD 1112 1.900 29 12 800 RIGD2 2.375 34 12 800 RIGD 21/2 2.875 40 12 800 RIGD 3 3.500 47 12 800 RIGD 3112 4.000 62 11 1000 RIGD4 4.500 67 11 1000 RIGD 5 5.563 80 11 1000 R1606 6.625 102 10 1000 RIGD8 8.625 123 10 1000 RIGD 10 10.750 143 10 1000 RIGD 12 12.750 198 10 1000 Pipe Clamps for E.M.T. Catalog Weight Metal Design Load at Number O.D. ibsJloo Gauge Safety Factor of S EMTC U2 .706 9 16 400 EMTC 314 S 11 1 6 .922 400 EMTCI 1.163 15 14 600 EMTC 11/4 1.510 18 14 600 EMTC 11l2 1.740 29 12 800 EMTC2 2.197 33 12 800 For 2112-31/2 and 4, use same size rigid damps. Universal Pipe Clamps for Rigid and E.M.T. Design Load Catalog Weight Metal at Number O.D. ibsJ100 Gauge Safely Factor o15 UNIV1/2 .701-.875 11 16 400 UNiV3/4 .917 - 15 14 600 1.081 UNIV 1 1.125- 17 14 600 1.375 UNiV 1114 1.500- 19 14 600 1.691 UNIV 1 1/2 1.735- 28 12 800 1.931 UNIV2 2.192- 33 12 800 2.400 Pipe Clamps for Copper Tubing Catalog Weight Metal Design Load at Number O.D. ibsJ100 Gauge Safety Factor of 5 0.D. CID 3/8 114 8 16 400 O.D. CP 1/2 3/8 8 16 400 O.D. CP 5/8 1/2 9 16 400 O.D.CP3/4 518 9 16 400 0.D.CPT/8 314 10 14 600 0.D. CID 1Its 1 14 14 600 O.D. CP 1 318 1114 15 14 600 O.D. CP 1 5/8 S 11/2 17 14 600 0.0.CP2118 2 30 12 800 http://www.tolco.com/strut-fittings/pipe-clamps/ . 9/21/2010 SWAY BRACING S 0 132 /Z r @c@ Fig. 980 omponeidofStateof Universal Swivel Sway Brace Attachment California OSHPD Approved Seismic Restraints System Size Range - One size fits bracing pipe 1 thru 2 inch, Tolstrut 12 gauge channel, and all structural steel up to 1/4 inch thick. Material— Carbon Steel. Function - Multi-functional attachment to structure or braced pipe fitting. Features - This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (1999 Edition) Table 64.5.9 indicates clearly that fastener table load values are based only on concentric loading. Fits multiple sizes of bracing pipe, strut or structural steel. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Application Note - Install per NFPA #13 and/or Tolco's State of California OSHPD Approved Seismic Restraint Manual. Installation - Place bracing component into jaw fully and tighten bolt until head breaks off. Approvals - Underwriters' Laboratories Listed in USA (UL), and Canada (cUL). Included in our Seismic Restraints Catalog approved by State of California Office of Statewide Health Planning and Development (OSHPD). •Note -The Fig. 980 Swivel Attachment and the Fig. 1000 "Fast Clamp", Fig. 2001, or Fig. 4A Pipe Clamp, make up a sway brace system of (UL) Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish - Plain. Note—Available in Electra-Galvanized finish. Order By— Figure number & Finish. Important Note -The Fig. 980 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the U.L. Listing requires that the Fig. 980 must be used only with other Tolco bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Max. Horizontal Design APPROX. A B H* Load LBS. WTJ100 v7 811312001 -163- Maximum Design Load I thru 4 inch pipe size-2015 ths. 6 inch size-1265 Lbs. (ID TOLCCY a brand otNIBCCY Revision 8/30/2002 scs w. 4flflfl I I. "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range - Pipe Size to be braced: 1 thru 6 inch Schedule 10 thru 40. Pipe size used for bracing: 1 and 1-1/4 inch Schedule 40 IPS. eAdditionàlly (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4 inch (maximum horizontal design load 655 lbs. Torque requirement 6-8 ft. lbs. Material - Carbon Steel. Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a TOLCO" 900 Series Fitting and joined together with bracing pipe per NFPA 13* orTOLCOTm OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Can be used to brace Schedules 7 thru 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as S longitudinal brace with Fig. 907. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1 inch pipe extension beyond the Fig. 1000 is recommended. Approvals - Underwriters' Laboratories Listed in USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by State of California Office of Statewide Health Planning and Development (OSHPD). Finish - Plain. Note— Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. Important Note - The Fig. 1000 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1000 must be used only with other TOLCOTh bracing products. Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruit,idge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118. Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com O TOLCCY a bmnd orNlBCO Revision 8/30/2002 Hg. 4 - Standard Pipe Clamp Fig. 4F - Standard Pipe Clamp Felt Lined Component of State of Fig. 4PVC - Standard Pipe Clamp PVC Coated California OSHPD Approved Seismic Restraints System S Size Range - (Fig 4)1/2 thru 30 inch pipe. Size Range —(Fig 4F) 1/2 thru 2-1/2 inch copper tubing. Material— Carbon Steel. Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use with Fig.330 Weldiess Eye Nut,Fig. 102 Eye Rod or Fig. 101 Welded Eye Rod.) Also recommended for attachment of sway bracing up to 3-1/2" pipe size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration and/or prevent electrolysis. Approvals - Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 314-8 Inch, and approved by Factory Mutual Engineering, 3/4 —8 inch. Federal Specification WW-H-171E, type 4, 1-1/2 thru 24 inch and Manufacturers Standardization Society SP-69, type 4. Included in our Seismic Restraints Catalog approved by State of California Office of Statewide Health Planning and Development (OSHPD). Note—When the Fig.4 is used as a sway brace, to ensure performance, the U.L. Listing requires that it must be used with other TOLCO1W brace product. / Maximum Temperature - 750°F. Finish — Plain. Note—Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, pipe size and finish. Fig4F Order Note —When ordering Fig. 4F allow for 3/16" felt on each half clamp. Fig.4 (4 Fig. 4PVC Max. Design Load Lbs. Pipe Sizes A B C D Bolt Size For Service Temp. APPROX. 650°F 750°F . 1/2 3-7/16 1/4 1-1/8 1-1/8 5/16 500 445 29 3/4 3-9/16 1/4 1-1/4 1-1/4 5/16 500 445 31 1 3-9/16 1/4 1-1/4 1-5/16 5/16 500 445 35 1-1/4 4-3/16 1/2 1-3/8 1-11/16 5/16 500 445 40 1-1/2 4-9/16 5/16 1-5/8 1-7/8 5/16 800 715 42 2 5-9/16 1/2 2 2-1/4 3/8 1040 930 93 2.1/2* 6-7/16 9/16 2-1/2 2-3/4 1/2 1040 930 126 3 7 5/8 2-3/4 3-1/16 1/2 1040 930 141 3.1/2* 7-11/16 3/8 3-1/8 3-3/8 1/2 1040 930 154 4 8-1/2 5/8 3-5/16 3-11/16 5/8 1040 930 229 5 9-3/4 3/4 3-7/8 4-3/8 5/8 1040 930 261 6 11-5/8 3/4 4-7/8 5-1/8 3/4 1615 1440 537 8 13-5/16 1 5-5/8 6 3/4 1615 1440 625 10 16-1/2 1 7-1/4 7-1/4 7/8 2490 2220 1378 12 18-1/2 1 8-1/4 8-1/4 7/8 2490 2220 1574 14 20 1-1/8 9 9 7/8 2490 2220 2103 16 23 1-1/8 10-1/4 10-1/4 7/8 2490 2220 2314 18 25-7/8 1-1/4 11-1/2 11-1/2 1 3060 2730 3276 20 28 1-3/8 12-1/2 12-1/2 1-1/8 3060 2730 3863 24 33-1/2 1-5/8 15-1/4 15-1/4 1-1/4 3060 2730 5222 .30 41-7/8 2 19 19 1-3/4 3500 3360 10511 Meets I.I.L. 203A requirements for attachment of sway bracing. Horizontal design load for 1/2-2" - 380#, 2-1/2% 395#, 3" - 435#, 3-1/2"- 540# Main Office/Manufacturing Facility 1375 Sampson Ave. ' Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruitridge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com 000 TOLcO ab,iiid(NIBC3 @C@ Fig. 800 componentoiStateof Adjustable Sway Brace Attachment to Steel Carufomla OSHPD Approved SeIsmic Restraints System Size Range— 4' thru 18' beam width. Material— Carbon Steel. Function - Seismic brace attachment to steel. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA #13 indicates the importance of concentric loading of connections and fasteners. Permits secure connection to steel where drilling and/or welding of brace connection could present structural issues. Comes completely assembled ready for installation. The Fig. 800 must be used with one of the Tolco Fig. 900 series brace fittings. (ordered separately) Installation Instructions—Tighten set bolts against flange until bolt head breaks off. Tighten hex head bolts into clamp body until lock washers are fully flat. Application Note - Allows bracing in either lateral or longitudinal direction. Approvals - Underwriters Laboratories Listed in the USA (UL), and Canada (cUL). Included in our Seismic Restraints Catalog approved by State of California Office of Statewide Health Planning and Development (OSHPD). Finish - Plain. Note—Available in Electro-Galvanized and HDG finish. Order By— Figure number, type number, size number. Important Structural note: Tolco Steel Fig. 65/66 components were used during structural testing and are required to achieve the listed results. Malleable iron comoonents must never be substituted because of their serious otential for fracture and failure. *DESIGN LOADS! LBS. FLANGE ALONG ACROSS TYPE THICKNESS MAX. BEAM BEAM 1 3/4' 1,265 2,015 2 1-1/4' 1,265 2,015 DESIGN LOADS! LBS. FITS BEAM ALONG. ACROSS SIZE RANGE BEAM BEAM 1 4'-6' 1,265 2,015 2 6'-8' 1,265 2,015 3 8-10' 1,265 2,015 4 10'-12' 1,265 2,015 ' 5 12' —14' 1,265 2,015 W 6 14'-16' 1,265 2,015 7 16-18' 1,265 2,015 SHOWN WITH FIG. 980 BRACE FITTING TO , -' PIPE BRACE (ACROSS BEAM) SHOWN WITH FIG. 980 BRACE FITTING TO PIPE BRACE (ALONG BEAM) W13P2001 -155- [11 RISER COMPONENTS S fl 10" (not shown) CO.4165.8N* Grooved 21h" thni 8" O 300 lb. WWP UL/FM Butterfly Valves Fire Protection Valve • Grooved Mechanical Style • Nylon Coated Ductile Iron • Extended Neck. Elastomer Encapsulated Disc • Accepts Internal and External Supervisory Switches 300 PS1120.7 Bar Non-Shock Cold Water 21/? -0" 175 PSI/12.1 Bar Non-Shock Cold Water 10" Ut/ULC LISTED • FMRC APPROVED • 2W - 10" UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHALL APPROVAL NO. 7770-1243:101 • APPROVED BY THE NEW YORK CITY MEA 9-97-E MATERIAL UST PART SPECIFICATION Upper Stem Stainless Steel ASTM A 582 Type 416 Upper Bushing PTFE Bronze Sintered on Steel O" Ring Buna-N Body Ductile Iron ASTM A 395 With Polymide Coating Disc Ductile Iron ASTM A 395 With EPDM Encapsulation Lower Bushinq FIFE Bronze Sintered on Steel 7. tower Stem Stainless Steel ASTM A 582 Type 416 Nameplate Aluminum r Gear Operator Cast Iron and Steel Indicator Flag Cast Iron 12. Handwheel Cast Iron f • II -. - -8N version has two thW mounted ilsp.ivi1ofyawifthes I 4N varsin is gear operaw only I Uses NISCO model tlS4Swltth Kit. F Polymide coating he. NSF csitificstion. / - -.-- r DIMENSIONS-WEIGHTS--QUANTITIES - Dimensions r _... - .....- Size A B C D E F C H L. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. 2½ 65 2.88 73 2.72 69 0.31 8 0.63 16 3.85 98 2.42 61 11.94 303 2.91 74 30.D.76.1 3.0076 2.8472 0.318 0.6316 3.85 98 2.42 61 11.94 3M 2.91 74 -" .3 80 3.50 89 3.34 65 0.31 8 0.63 16 3.85 98 2.86 13 12.48 317 2.91 74 4100 4.50 114 4.33 110 0.38 10 0.63 16 4.56 116 3.84 9814.18 360 2.9174 5 125 5.56 141 5.39 137 0.38 10 0.63 16 5.86 149 4.79 122 15.17 385 2.91 74 ' j 6 150 6.63 168 . 6.45 164 038 10 0.63 16 5.BB 149 5.73 146 17.54 446 2.91 74 r 60.0.165.1 6.51 165 6.32 161- 038 10 0.63 16 5.86 149 533 146 17.54 446 2.91. 74 8 200 8.63 219 8.44 214 0.44 11 035 19 526 134 731 196 19.42 493 2.91 74 10 250 10.75 273 10.56268 0.50 13 0.75 19 6.29 160 &56 243 24.M 610 3.90 99 .). .. Dimensions - Size J K L M N P 0 H Weight In. mm. In. mm. In. mm. In. mm. In. mm.In.mm. In. mm. In. torn. In. mm. Um. Kg. I1i 2½653.54902.13545.821485.671444.191063.25835.91503.46882210.0 --••J_: 'I 30.0.76.13.54902.13545.821485.671444.191063.25835.91503.46882210.4 : 3 80 3.54 90 2.13 54 522 148 5.94 151 4.44 113 3.54 90 5.9 150 3.97 101 23 10.4 'T 4 100 3.54 90 2.13 54 7.64 194 6.31 173 5.33 135 4.35 110 5.9 150 5.03 128 28 12.7 .__ .... 5 125 3.54 90 2.13 54 7.64 194 7.32 186 5.83 148 4.84 123 5.9 150 6.27 159 31 14.1 . r 6 150 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 60.0.165.1 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 , 8 200 3.54 90 2.13 54 7.91 201 9.80 249 8.05 204 6.81 174 9.8 250 9.25 235 53 24.1 . 10 250 3.98 101 3.03 77 9.49 241 11.61 295 9.86 250 9.17 233 11.8 300 11.25 286 88 40.0 r NIBCO INC WORLD HEADQUARTERS • 1516 MIDDI.EBURY St s EIKHART. IN 46516.4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX +1.574.295.3455 www.nito.ccm 06/03/2010 08:27 5626907446 DANGELO Co PAGE @1/08 Fr&..ock' 3L4h' Vahe SERIES 705 WITH WEATHERPROOF ACTUATOR Ihc Series 705 butterfly valve features no aoproved weatherproof actuator housing approved lot indoor or outdoor use. It Ii.,, C ductile iron body and disc with Nitrite seats. Designed lot lire protection services only. Series 705 valve Is UI. Listed and FM Approved for 300 psi/206B kPa service. Contact Viotautic for details of agency approvals. MATERIAL SPECIFICATIONS Body: Ductile Iron conforming to ASTM A-536, grade 65.4542 End Face. 2 - 6"/BO - 150mm: Ductile iron conforming to ASTM A.536. grade 65.45.2 Seal Retainer, 8 - I2I200 - 300mm: Ductile iron r.nrufntmtn 'o ASTM A.536. grade6•4•i CoMIng: black alkyd enamel DIsc: Ductile Iron coaformInp to ASTM 4.536 roc 65.45.12, with cicctrolcz nicKct cootItu Gull- forming to ASTM 8-'33 Seat: S Grade T Nitute Stems; 416 stainless steel contorminp to ASTM A.52 Stem Seal Cartridge: C36000 brass Bearings: Stainless Steel with TFF lining Stem Seals: Nitrite Stem Retaining Ring: Carbon sleet Actuate,: 2 . 8750 . 200mm: Bross or bronze traveling nut on a steel le-Ad screw. In a ductIle ifuii tiouiing 10. 171750 300mm; Steel worm and cast Iron quadrant gear, in a cast iron hnusii,p JOB/OWNER CONTRACTOR ENGINEER System No...._ Submitted By Spec Sect _ Para_, Location Date -- ........Approved Date_.....--_________________ www.victaulic.com vICTAULIC IS Rft:uslyllr,Q TusApeMAnlu Or VTAULuc COMPANY. C rzn VlITui)ljC COMrAnrv. PCIr 4 06/03/2010 08:27 5626907446 DANGELO Co PAGE 02/08 jpS C4RON ,TEEL PIPE - FIRE PROT(CTIQN VALVES FweLocButterfly vaqfve SERIES 705 WITH WEATHERPROOF ACTUATOR DIMENSIONS - 10.81 • _______ lOft I 3' ).3) ".b 2,20 6,41 4.00 4.72 450 7.0 I 00.1 MITI 6') 3080 57.9 1628 - 101.6 10?.) 111.1 R 2W 2.875 3.77 2.20 7.54 4.00 4.22 4,50 I.7 - I mm 73.0 _73 95.9 57.9 191. - -. 0 1.6 I07, 114.11 45.0 I 1.000 3.77 2.28 1.54 m,i)fl "j'. 4,5)) 1,;7 761,A11%1 76.1 950 37.9 1913. - - 101J 107.2 114.3 45.0 __J 3' 3.301, 3,77 2.53 7.79 4,50 4,)) 4..II 1,77 K9 mm 86.9 95.0 613 197.9 - - II&) I113 114.5 45fl 4.250 6.63 2.00 8.0 5.311 4.22 4,59 z.o 108mm 108.0 117.0 73.2.L'3.9 - I)9.7 11,1) Iii.) 55.9 4 4..00 4.63 Zee 0.41 5.50 4.72 4.5)) L' 114.) aim 114.3 117.6 73.2 223.6 - 1.14.7 IA7, i,&s wp } 5.750 SM US 1Q.86 0.55 6.19 6.30 2.59 133 rpm 133.0 I49A 0"...),7(..4 " - 166.6 IS).) IIIM 6'i'. .5.500 S.Be 3.35 10.88 6.515. 6,19 1)30 2.50 ..1397hI I39,7 149.'. 05.1 2.76.4 - - 11)0.1) 157.2 160.0 63.0 S. 5.583 5.89 .l:; ")99 6.50 6.19 6.3)) )39 141.3 mm 141.3 149.4 95.1 27(..a " I6.6 )57) Id)).)) &... I-. (..)'3) '.M0 7.1)4 11.36 O.'l 7.52 6.I3 1)3(1 2.33 8 15(b aim 159.)) 14J,4 97,5 )99.I 30.4 191.0 I5'.) 14').)) (.5.5 - • 9.5)70 5.88 3.04 1011 0."I '.52 6.11' ('.30 7.9 rj3, mm 165.1 119.1 97.S 209.1 - 111.4 191.0 357) 160.0 45.5 6 6.675 3,8.9 3.04 1131 - 9,41 7.5) 6I9 13,3U 1.90 30.3 149 97.5 209.1 10.4 191.9 157.2 160.0 'It] 8' ! 1625 5.33 5.07 13.32 020 1.47 30,00 6.10 A,10 233 2)9.) mm 219.) 175.4 328.9.143.6 20.3 37.3 254.0 1S7.2 293.7 SP. 30' II),69 . &40 0.37 15.64 1.41 1.01 12.25 9.30 9.00 - P3 mm 271.0 162.6 161.0 797.3 is.o 46.0 311.2 205) ))A. 32' 12,750 6.50 7.36 16.64 2,70 2.39 14.75 0.10 9.00 - 723.9 mm 373.9 16.l 186.9 422.7 501 . 71.1 302.0 7m1,7 229.6 www.victiulie.com VIC!4UL11 '84 Rr.C3I5Tr.R(I) TRADEMARK OF VICTAULIC COMPANY. 0 PIU) VICTAULIC COMPANY. hIL&. 06/03/2010 08:27 5626907446 DANGELO CO PAGE 03/08 IrS c;nRIoN I.-TIP. PIPE - FIRE PRQOTrTi01J VALVES 10.81 r&c E; flry Vahie SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE The chart crosses the ftichonal resistance of Victeulir Series 705 8u1er1Iy 'delve in equivalent 5ch' mdc's 01 straight pipe. 0 6 6.05 10 (0.3 l. ISO 11(8.2 --...710 1.8 IOrnm 158mm 3.000 1 165.1 mrn 14 76.1 18 2 5.501) 7 8 I', eo 2.1 200 2Ir.; 49 - . 7 --.. .. a io rni'n is tOO 1I& -. 2.4 250 i 71fl 53 108 mm 188mm 8 12 I EXhA IS 3•4 300 59 3 .9.5113 12 US J 1415 3.7 133 mm I33m6 3.7 Soo 1.19.7 mn', 12 . www.vicbulic.com VICTAULIC IS A IIcrmTr.RF.Q TRADEMARK OF VIr.TAIJLIC COMPANY. 0 3079 VICTAUIJC COMPANY. IiiV • :I.:i 06/63/2018 08:27 5626987446 DANGELO CO PAGE 04/08 vLvr 10.81 IPS Mf3OW :rCEl. PIPE FIRE PR()TEIrPOh1 uttfly Vaive • SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE Cv values for 110w of water at +60F/+16'C with a fully 000n VlvC arc Shown in the thIp. bpJcsw. For additional details, contact 1/IctaulIc. Formulas for Cv Values: AP = Where: C) Flow (tiFM) 0. (., x SAP AP — Pscssvr. Drop (psi) C. Flow Co.rfir.ienl -2.375 5 170 5.563 ... a 6.671. 3-100 I 60.3 7.00 Ifl 2A 2.075 05 73.0 261) 133mm 133 mm 1200 250 i 271c i 30 in 139.7mm Soo 1200 300 I1W 3 3.570 .141.3 Ado 1000 68.9 ISo 160.3 10D 114.) 620 159mm 1000 lOB mm 106 mm 820 ir.s,i mm Soo 1000 Formulas for Ky Values: AP = 0' Where: OFIuw() At' = PTnMIIu' (h21) K,= F low lcu,r JAY% 147 5 r-50 1040 a G•63•• I '.0,3 US 141,3 200 7IU 1 '5 133mn 131 Aim 1040 2 to 50 l0)fl SWO 10 76.1 mm " 10411 li 72" 300 33,il 3 2.500 6 an :1560 6b25 iso i6e. 4 100 'I.0O 111.3 710 l',9 rpm . 1501nm 1.60 106 mm 106 mm 710 9, 6.500 165.1 1560 www.vlclaulic.com . vir.TA'.'LIC IS RCISTCR00 1 MACErAARI(OF VICIAIII It e.nMPANY. 0 2009 VIVAIJUr 'OMIMNY. ..! Dior 11,3194 " 06/03/2610 08:27 5626907446 DANGELO CO PAGE 05/08 IPS CARSON STEEL PIPE FIRE PROTECTION VAI.VE 10.81 FireLordvr Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING The supervisory switch contains two, single pole, double thrOw. pre-wired switches. Swftclics arc rated: 10 amps @ 1.25 or 250 VAC/60 tz 0.50 amps a 125 VDC 0.25 amps @ 250 VOC Switches supervise the valve In the opee" position. One switch has two 018 insulated wires per terminal, which l)ormil Comeleto Supervision of leads (refer to diagrams end notes below). The second switch rtas one #18 insulated wire per terml. nl. This double circuit provides flexibility to operate twn electrical devices at separate locations. such as on indicating light and an audible alarm. in the area that the valve is installed, A #14 insulated ground lead (green) is provided. Switch #1 = SI For connection to the supervisory circuit of a UI. Listed alarm control panel Switch 02 = 52 Auxiliary switch that may be connected to auxiliary devices. par the authority having jurisdiction {Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe 32 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe __ F 2;'. E1 NOTE: The above diagram shows a confection between the common terminal (yellow - Si and yellow-with-orange stripe .. MOM the normally closed terminal (blue - SI and blue.-with.o,ange stripe - S.). In this example, the indicator light and alarm will slay an until the valve Is fully open. When the valve is fully open the indicator light and claim will go out. Cap off any unused wires (e.g. brown with orirngo Stripe). Only Si (two leads nor terminal) may be connected to the lire alarm control panel, The connection 01 the alarm switch wiring shell be in accordance wIth NFPA 72 and the auxiliary switch per NFPA 70 (NEC). www.victaulic.com VICTALII,lC iS A RLGIStRFA T5aOtMdRI( or VILTAULIC COMPANY .2005a 2005 VW.?AIJUc COMPANY. REV A 06/63/2010 08:27 5626907446 DANGELO Co PAGE @6/08 SERIES 705 WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Worronly section or inc current Price List or contact Victziulic for details. NOTE This product, shall tie m3nufaclurcd by vtclauilc or to Vicraulic cpcitir.ations. All oroiucts to Lic instelled in ar.CWCtanCC with CurrCflt Vicraulic installation/assembly instructions. ViClt,liC rvservvt the riRht to chanc Product 5CcciiIcalicn. designs and 51end3r11 eqtiinen( without notice i'.ncj wlthuul incurrinp. obligations. INSTALLATION Reference Should always be made to the insiClittion sheet included with (ho valve. Verity you have the latest revisian by visitirip oiir websitc at www.vlcraullc.com. Further ,elerenr.e can be lijit in the 1-300 VlcteuuiC Field 1n51011a110n Honcibouk. of complete ci'jtact Information, visit WWW.yjCtaulic.com IOU) Mf..Ova UPDATED 4I000 .ct.auij VICIAIII fr.IS A (l) II$Tdp IWAUI MARK r VICTAULIC COMPANY. 0 2000 VIC1'A1.11,1c r.nMpAN' MODEL 7500 The AGF Manufacturing, Inc. Model 7500 Pressure Gauge is a Factory Mutual Approved and Underwriters Laboratory Listed 31/2" gauge designed for use on "wet" sprinkler systems. The AGF Model 7500 has been designed to meet NFPA System Attachments requirements as specified in NFPA 13 Sec. 4-7.3. The Model 7500 fulfills the installation specifications for a pressure gauge as stipulated in NFPA 13 Sec. 3-1.1, 3-7.7,4-6.1.2.2, NFPA 13D Sec. 3-2, and NFPA 13R Sec. 2-4.3. RANGE 0-300 psi (inside) 0-2000 Kpa (outside) ACCURACY ±3-2-3% BURDON TUBE Phosphor Bronze WINDOW Polycarbonate one-piece ring and crystal DIAL Galvalume POINTER Aluminum, painted black CASE PGE Xenoy® DX2735 CONNECTION Brass, 1/4" ANPT LM S DIMENSIONS /411 3-WAY GLOBE VALVE NFPA 13 SEC. 5-15.3.1. ...EACH GAUGE CONNECTION SHALL BE EQUIPPED WITH A SHUTOFF VALVE AND PROVISION FOR DRAINING. 1.16 0 3.46 (MM) - - 9NPT 1boo AGF Manufacturing, Inc. provides many different products to address a variety of job conditions. Please contact our office for advice and products modified to solve specific job conditions. Thank you for using our products. oul Our AUtOC AGF MANUFACTURING INC. I on the Internet Maivern, PA 19355 USA Visit us 0, 100 Quaker Lane at Telephone: (610) 240-4900 Fox: (610) 240-4906 www.testandroin.com 10/01 JOB NAME: - ARCHITECT:- ENGINEER: - CONTRACTOR: nciflcadon Sistant T-235-Y Threaded S-235-Y Solder T-235-Y NPT x NPT S-235-Y CxC , Class 150 Bronze Globe Valves Union Bonnet • Integral Seat • Renewable Seat and Disc 150 PSI/103 Bar Saturated Steam to 366° F/185° C 300 PSI/20.7 Bar Non-Shock Cold Working Pressure CONFORMS TO MSS SP-80 MATERIAL LIST PART SPECIFICATION Handwheel Nut 300 Series Stainless Steel Identification Plate Aluminum Handwheel Malleable Iron ASTM A 47 4 Stem Silicon Bronze ASTM B 371 Alloy C69400/C69430 Packing Gland Bronze ASTM B 62 or ASTM B 584 Alloy C84400 or Brass ASTM B 16 Packing Nut Bronze ASTM B 62 or ASTM B 584 - Alloy C84400 or Brass ASTM B 16 - . Packing Aramid Fibers with Graphite 8. Bonnet Bronze ASTM B 62 - -UnionNut BronzeASTMB 62 10. Body Bronze ASTM B 62 11. Disc Holder Bronze ASTM B 62 Disc Steam (PTFE) (Y) Disc Nut Bronze ASTM B 62/ASTM B 98 Alloy C65100 w/SS Washer DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Master t½ 6 2.31 59 3.88 99 2.00 51 1.21 0.55 1.06 0.48 50 50 t¼ 8 2.31 59 3.88 99 1.88 48 1.19 0.54 1.05 0.48 50 50 t% 10 2.38 60 3.88 99 1.75 45 1.17 0.53 1.03 0.47 50 50 1h 15 2.69 68 4.63 118 1.88 48 1.60 0.73 1.38 0.62 40 50 'Y4 20 3.19 81 5.38 137 2.31 59 2.34 1.06 2.21 1.00 20 20 1 25 3.75 95 6.00 153 2.88 73 3.55 1.61 3.35 1.52 10 20 11/4 32 4.25 108 6.56 167 3.13 79 5.76 2.61 4.93 2.23 10 10 1½ 40 4.75 121 7.38 187 3.75 95 7.59 3.44 7.17 3.25 6 10 2 50 5.75 146 8.31 211 4.50 114 12.56 5.70 11.02 5.00 4 4 2½ 65 6.63 168 10.19 259 5.38 137 17.44 7.91 17.16 7.79 2 2 3 80 7.75 197 11.13 283 6.50 165 23.87 10.83 22.82 10.35 2 2 t No packing gland, packing only in these sizes. Freezing Weather Precaution - Subsequent to testing a piping . system, valves should be in an open position to allow complete drainage. For detailed Operating Pressure, refer to Pressure Temperature Chart on page 111. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDIEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.600.234.0227 TECH SERVICES PH: 1.888.446.4226 • FM: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.mbco.com