HomeMy WebLinkAbout6020 AVENIDA ENCINAS; ; FA080016; Permituity OT uarisbad Fire Alarm Permit Permit No: FA080016 6020 AVEN IDA Job Address: Status: ISSUED ENCINAS Permit Type: FALARM Applied 2/12/2008 Parcel No: 2110302700 Approved: 2/13/2008 Lôt#: .0 Reference No.: Issued: 2/13/2008 PC #: Inspector: Project Title: TOYOTA CARLSBAD 2 FIRE ALARM INSPECTIONS @ $65/EA Applicant: TRI-SIGNAL INTEGRATION UNIT 8380 VICKERS SAN DIEGO, CA 858-571-1658 Owner: STELLAR PROPERTIES L L C C/O LEXUS CARLSBAD 5444 PASEQ DEL NORTE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) L 130 0 130 0 9682 Via Excelencia, Suite 105 San Diego, CA 92126 TRI.SIGNAL im Tel (858) 537-3444 I N T E 6 RAT I 0 N, I N C. Fax (858) 537-3433 www. fri-signaL corn I I I I I I I I I I I I I 1 I I 1 TOYOTA CARLSBAD 6020 AVIENDA ENCINIAS CARLSBAD, CA. 92011 FIRE ALARM SYSTEM APPROVEDUBMITTED CARLSBAR'kRTMENT SUBMITTAL 11 FILE* COPY 1/2/2008 FAoqg ool( REV.#: 0 PROJECT #: 07-024-20 10 FAX (858) 537-3433 T R I • S I 6 N A L TEL (858) 537-3444 INTEGRATION, INC. TOYOTA CARLSBAD SUBMITTAL PROJECT: FIRE ALARM SYSTEM TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CALIFORNIA 9201 1 9682 Via Excelencia a Suite 105 0 San Diego, California, 92126, 858-537-3444 (ph) 858-537-3433 (fax) FIREoSECURlTYoCC1VoACCESS CONTROLOPRO-SOUNDS INTERCOMO CLOCK SYSTEMSO INTRUSIONO TELECOMMUNICATIONSO DATA NETWORKS. NURSE CALLO LICENSE NO. 758792 %AIkei+. ,i,,an*, fr_o,riri'I -rm iz FAX (858) 537-3433 1 R I • S I G N A L TEL (858) 537-3444 INTEGRATION, INC. TOYOTA CARLSBAD, EJUIPMENT LIST & DATASHEETS ITEM MODEL # DESCRIPTION CSFM # A LICENSES B NFS-320 C FSP-851 FST-85 1 B710LP D NBG-1ZLX E FDM-1 FRM- 1 F FSD-7S1PL G P2R FIRE ALARM CONTROL PANEL INTELLIGENT SMOKE DETECTOR ADDRESSABLE HEAT DETECTOR LOW PROFILE DETECTOR BASE ADDRESSABLE PULL STATION ADDR DUAL MONITOR MODULE ADDRESSABLE RELAY MODULE ADDRESSABLE DUCT DETECTOR MULTI-CANDELA HORN/STROBE 7165-0028:243 7272-0028:205 7270-0028:1 96 7300-0028:173 71 50-0028:1 99 7300-0028:202 7300-0028:202 3240-0028:205 7125-1 653:188 11 9682 Via Excelencia C Suite 105 e San Diego, California, 92126, 858-537-3444 (ph) 858-537-3433 (fax) FIRE oSECURITYOCCTVoACCESS CONTROLIPRO-SOUNDO INTERCOMO CLOCK SYSTEMS* INTRUSIONO TELECOMMUNICATIONSO DATA NETWORKSO NURSE CALLO LICENSE NO. 758792 AIhosh AII*AAI +r_nn& ,',m j" TRI .S I 9 NAL '. FAX (858) 537-3433 INTEGRATIDN,,NC. Contractor License. #758792 9682 Via Excelencia . Suite 105. San Diego, California, 92126, 858-537-3444 (ph) 858-537-3433 (fax) FIRESECURITY.CCW.ACCESS CONTROLOPROSOUNDC INTERCOM. CLOCK SYSTEMS. INTRUSIONS. TELECOMMUNICATIONS, DATA NETWORKS, NURSE CALL. LICENSE NO. 758792 IAA*R*I +rLou,nI gr,m NFS-320 Intelligent Addressable Fire Alarm System General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-medium system, or as a large net- work, the ONYX Series of products meets virtually every applicatibn requirement. Designed with modularity and for ease of system planning, the NFS-320 can be configured with just a few devices for small building applications, or for a large campus or high-rise appli- cation. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific or "E at the end of the part number, WFS-320 refers to models NFS-320, NFS-320C, and NFS-320E; similarly, CPU-32O refers to models CPU-320, CPU-320C, and CPU-320E. Features Listed to UL Standard 864, 9th edition. One isolated intelligent Signaling Line Circuit (SIC) Style 4, 6or7. Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (N.O. manual stations, two- wire smoke, notification, or relay). 318 devices maximum. Standard 80-character display. Network option - 103 nodes supported (AFP-200, AFP- 300/400, NFS-320, NFS-640, NFS2-640, AFP1010, AM2020, NFS-3030, NFS2-3030, NCNNCA-2 Network Annunciator NCS Network Control Station, or ONYX- Works Network Control Station) using wire or fiber-optic connections. 6.0 amp power supply with four Class NB built-in Notifica- tion Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, and Supervisory relays. VeriFire® Tools offline program option. Sort Maintenance Reports by compensation value (dirty detector), peak alarm value, or address. Autoprogramming and Walk Test reports. Optional universal 318-point DACT. 80-character remote annunciators (up to 32). ElA-485 annunciators, including custom graphics. Printer interface (80-column and 40-columnprinters). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with tally. Autoprogramming and Walk Test reports. Positive Alarm Sequence (PAS) Presignal. Silence inhibit and Auto Silence timer options. March time / temporal / California two-stage coding I strobe synchronization. Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. Full QWERTY keypad. Charger for up to 90 hours of standby power. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. DN-7112:A2 • A-14 NOTIFIER® by Honeywell Ii I I NFS-320 Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES: Poll 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. MuTticolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - nine levels. Pre-alarm ONYX intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows:• - Ion —0.5 to 2.596/foot obscuration. - Photo —0.5 to 2.350/a/1"oot obscuration. - Laser (VIEW®) —0.02 to 2.0%/foot obscuration. - Acclimate Plus' .- 0.5 to 4.00/a/foot obscuration. - HARSHTh' —0.5 to 2.35%/foot obscuration. Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the CPU-320 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU-320 NAC cir- cuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing. Maintenance alert (two levels). Self-optimizing pre-alarm. DN-71 12:A2' 8/3/01 - Page 1 018 I I I L WEW(VERY INTELLIGENT EARLY WARNING) RELEASING FEATURES: SMOKE DETECTION TECHNOLOGY: Ten independent hazards. Revolutionary spot laser design. Sophisticated cross-zone (three options). Advanced ONYX intelligent sensing algorithms differentiate Delay timer and Discharge timers (adjustable): between smoke and non-smoke signals (U.S. Patent Abort (four options). 5,831.524). Low-pressure CO2 listed. Addressable operation pinpoints the fire location. HIGH-EFFICIENCY OFFUNE SWITCHING No moving parts to fail or filters to change. Early warning performance comparable to the best aspira- 3.0 AMP POWER SUPPLY (6.0 A IN ALARM): tion systems at a fraction of the lifetime cost. 120 or 220/240 VAC. ACCLIMATE PLUS Displays battery current/voltage on panel (with display). LOW-PROFILE INTELLIGENT MUL TI-SENSOR: VOICE FEATURES: Detector automatically adjusts sensitivity levels without Integrates with FireVoice-25/50 Series. operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. FlashScan or classic mode compatible with NFS2-640. NFS-320. . - Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). HARSH HOSTILE-AREA SMOKE HEAD: Provides early warning of smoke detection in environment where traditional smoke detectors are not practical. The detector's filters remove particulätes down to 30 microns in size. Intake fan draws air into photo chamber, while airborne par- ticles and water mist are removed. Requires auxiliary 24 VDC from system or remote power supply. Up to 32 Remote Displays. SLC intelligent Loop } ----[:jr1 ®i _______ - - I FSFI-751 flashScon€iHARSH°' NOG-I2LX FMM-1 FRM-1 XP6I1O FDU-80 FDU-80 I FSP451 flashScan® photo A FO I I/O Modules -5 I IDC Relay Contact Il 0 DODD EtA -485 2048 annunciato,/conlml points lid ACM-811 ACMIAEM-24AT LDM42 NFS-320 Relay Control LED Annunciator Custom Graphics Opdunal 318 point UDACT Dual phone lines to Central EIA-232 Terminal Station Sample . jn111m System El EIA-232 Options PRN Printer CRT-2 Terminal 7112btak.wmf Page 2 of 8— ON-7112:A2 - 813107 U I ,. FlashScan, Exclusive New Field Programming Options World-Leading peteótor Protocol Autoprogram is ,a timesaving feature of the NFS-320. It is a - At the heart of the NFS-320 is a set of detection devices and special software routine that allows the NFS320 to learif device protocol - FlashScan (U.S. Patent 5,539,389). Flash- what devices are physically connected and automatically load.., Scan is an all-digital protocol that gives superior precision and them in the program with default values for all parameters. high noise immunity. Requiring less than one minute to run, this routine allows the In addition to providing quick identification of an active input user to have almost immediate firs protection in a new installa- . tion, even if only a portion of the detectors are installed. device, this new protocol can also activate many output devices in a fraction of the time required by competitiveproto- Keypad Program Edit (with KDM-R2) The NFS-320, like all - - cols. This high speed also allows the NFS-320 to have the NOTIFIER intelligent panels, has the exclusive feature of pro- largest device per loop capacity in the industry - 318 points - gram creation and editing capability from the front panel key- • - yet every input and output device is sampled in less than pad, while continuing to' provide fire protection. The two seconds. The microprocessor-based FlashScan detectors architecture of the NFS-320 software is such that each point have bicolor LEDs that can be coded to provide diagnostic entry carries its own program, including contiol-by-event links informatidn, such as device address during Walk Test. to other points. This allows the program to be entered with I , - . . independent 'per-point segments, while the NFS320 simulta- ONYX Intelligent Sensing - neously monitors other (already installed) points for alarm con: Intelligent sensing is a set of sofbiare algorithmsthat provides. VeriFire Tools is an offline programming, and test utility that I . the NFS-320 with industry-leading smoke detection capability, can greatly reduce 'installation progràmrning time, and - These complex algorithms require many calculations on each increase confidence in the site-specific software. It is Win reading of each detector, and are made possible by the very dows®-based and provides technologically advanced capabili- . high-speed microcomputer'used by the 9FS-320. ,.. ties to aid the installer. The installer may create the entire I . Drift Compensation and Smoothing: Drift compensation - program for the NFS-320 in the comfort of 'the office, test it, : allows the detector to retain its original ability to detect actual store a backup file, then bring it to the site and download from • smoke, andr resist false alarms, even as dirt accumulates. It a laptop into the panel. reduces maintenance requirements by allowing the system to I automatically perform. the periodic' sensitivity, measurements . Below: Autoprogi-am function. required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference r - - Maintenance Warnings When the drift compensation per #1 1 ii OCr PLEAS L WAIT I formed for a detector reaches a certain level, the performance .. ", . . s." .. ... of the detector may be compromised and special warnings are given.. There are three warning levels: (1) Low Chamber -...- ... . . - .... . •• ..... value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert indicative of dust accumulation that is near but below the allowed limit (3) Maintenance Urgent ' L 80 DFTS 15 MODS indicative of dust accumulation above the allowed limit 80 LS 04 Sensitivity Adjust Nine sensitivity levels are provided for '. •'. ... detection. ,These levels can" be set manually, or can . . . ........ I - 'alarm change automatically between day'and night. Nine levels of - . pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self restoring and can be used to activate special control func- I tions. - . Self-Optimizing Pre-Alarm: Each detector may be set for Self Optimizing pre alarm In this special mode the detector AR learns its normal environment measuring the peak analog I readings over a long period of time, and setting the pre-alarm level just above these normal peaks 4 Cooperating Multi Detector Sensing A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or I , pre alarm decisions Without statistical sacrifice in the ability to resist false alarms it allows a sensor to increase its sensitivity to actual smoke byafactor of almost two to one. ,:. .. •..: • i___ I ". VeriFire Tools System Programming screen I I I DN1112A2 8/3/07— Page 30:8 1 1 TB9: NA LEDs 11 TBB: NA LEDs 13 TB7: NAt LEDs 15, TB6: NAt LEDs 17, TBS: Ret Supervisi Security U ii I I . I I I. U I I. I I I I . I . j II I J2 I1J3 TB13: SIC Loop #1 (supervised, power-limited). JP1: Ground Fault Jumper (SLC #1). Jr allo caM MR At left' 12 - Fzo TM SW1: Ground Fault Detection Enable/Disable. 14 F2:115 A Sb-Blow Fuse, P/N 12057. J8: Zone Coder Connection. r, TB3: Battery Connection; over-current protected, EAM non-power-limited. 157 FALIT #3 16 LED3: Earth Fault board ir 1J (general ground läutt). Too E 14 18 TB1:ACPower Connection H (non-power-limited): Hot, , Neutral, and 701 Earth Ground. lll(a 0 e 0 0 0 0 iys: vor D 0 0 0 0 155 1ii 0000®® Um 9l I J6: Auxiliary Trouble Input. J JS: Security Tamper Switch. o tl:I:.l:l:l:l:rl:lJf @1 Sw1234 LED ?65432ilr TB4: Alarm Relay, Trouble Relay. SW1, SW2. System switches, J7: KDM-R2 LED1: Power On (AC or battery) No Output relays; power-limited only if to SW3, SW4: Disable -Enable Keyboard Connection LE02: Signals Silenced connected a power-limited source. Operatlon: LED3- Point Disabled switches for Backup SWS Acknowledge LED4 System Wbl - 7ll2baia.wml Alarm,espedy NACs 1 SINS Silence LED5: Supervisory • SW7 Reset LEDB: Security LE07: Pre-Alarm • LED8: Fire Alarm Network Diagram iI _iI • ____ RP - NCSor ONYXWorks Block Diagram RP NOTI'FIRE'NET i 24 Sample Node configurations PRN NFS-320 KEY: PRN NFN Twisted-Pair Wire NFN Dual FiberLink I I .-ACS -Optic "1!J Other Interfaces iii11$i . - FDU-80 ACS PRN OPTIONAL NCS or ONYXWorks Style 7 Connection PRN IlW11tlII ACS Page 4 or - DN-7112:A2'813107 CPU-320 Board Diagram All NAC circuits are power-limited, supervised. TB1O: DC Power (24 VDC. power-limited); Non-Resettable. Resettable. ii: Network/Service Connection (NUP). Tell 11: EIA-485 Connection (supervised); Terminal Mode, ACS Mode, power-limited, supervised. TB12: ElA-232 Connection; Printer. PC/Terminal (CRT). J2: IJSB A VeriFire Tools Connection. J3: USB B VerlFire Tools Connection. - LED1O:SLCLoop - Ground FaUlt, Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as dis- cussed in the NFS-320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a NCM-W (wire) or NCM-F (fiber) Network Con- trol Module. The NCM-W/-F can be installed in any option board position (see manual). Option boards can be mounted in front of the NCM modules. KDM.R2 Controls and Indicators Program Keypad: QWERTV type (keyboard layout). .12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Membrane Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Configuration Guidelines The NFS-320 system ships assembled; description and some options follow. NFS-320: The standard, factory-assembled NFS-320 system includes the following components: one CPU-320 control panel mounted on chassis (120 V operation - ships with grounding cable, battery interconnect cables, and document kit); one .KAPS-24 integral power supply mounted to the CPU- 320; one primary display KDM-R2 keypad/display; and one cabinet for surface or semi-flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet; additional option boards can be utilized in remote cabinets. NFS-320R: Same as NFS-320 above, but in red enclosure. NFS-320C: Same as NFS-320 above, but with .ULC listing. See Canadian applications manual addendum 52747. NFS-320E: Same as NFS-320 above, but with 240 V operation. BMP-1: Blank module for unused module positions. 711-326 Trim ring for the NFS 320 cabinet. Keypad/display unit attaches to chassis rails. SLOT 1: CPU, KAPS-24, and primary display. SLOT 2: CPU, KAPS-24, and primary display. i- SLOT 3: Mounting location, option board. I I Panel ships factory- assembled, with chassis installed with CPU, KAPS-24, and KDM-R2. Equipment Placement in NFS-320 Chassis () 7ll2chs.wmt DN.7112:A2• 8/3/07 - Page 5 0r8 I I I I I I I I Option Modules FCPS-24S6/-24S8: Remote six-amp and eight-amp power supplies with battery charger. See FCPS-24S6/-24S8 data sheet, DN-6927. COMPATIBLE DEVICES, EM -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095!S2: Printer, 40-column, 24 V. Mounted in external backbox. See DN-3260. CRT-2: Video display terminal. See DN-3756. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24A1: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-86.2. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch seleC- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. TM41: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit; mount on NFS-320 chas- sis or remotely. See DN-6860. FDU-80: Remote LCD display, 80 characters, with LEDs. See DN-6820. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32; remote custom driver modules. See LDM data sheet, DN-0551. ACM-811: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ACM-BR data sheet, DN-3558. RPT-485 Series: Repeater, isolator and/or fiber-optic modem; repeats EIA-485 over twisted pair or converts to fiber-optic medium. See RPT data sheet, DN-4737. SCS: Smoke control stations SCS-8, SCE-8, with lamp driv- ers SCS-8L, SCE-8L; eight (expandable to 16) circuits. See SCS data sheet, DN-4818. - UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microproces- sor-controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). See UZC-256 data sheet, DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit 01 FSB-200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. BEAMMRK: Multi-mount kit, FSB-200(S) below. BEAMSMK: Surface-mount kit, FSB-200(S) below. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6895. FSl-851: Low-profile FlashScan ionization detector, will replace FSI-751. See DN-6934. FSI-751: Low-profile FlashScan ionization detector. See ON-6714. FSP-851: Low-profile FlashScan photoelectric detector, will replace FSP-751. See DN-6935. FSP-751: Low-profile FlashScan photoelectric detector. See DN-6714. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal, will replace FSP-751T. See DN-6935. FSP-151T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6714. FST-851: FlashScan thermal detector 135°F (57°C), will replace FST-751. See DN-6936. FST-751: FlashScan thermal detector 135°F (57°C). See ON-6716. FST-851R: FlashScan thermal detector 135°F (57°C) with rate-of-rise, will replace FST-751 R. See DN-6936. FST-751R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6716. FST-851H: FlashScan 190°F (88°C) high-temperature ther- mal detector. See DN-6936. FSD-751P: FlashScan photo duct detector with housing. See DN-6821. FSD-751PL: Low-flow FlashScan photo. duct detector with housing, will replace FSD-751P. See DN-6.955. FSD-751RP: FlashScan photo duct detector with relay and housing. See DN-6821. FSD-751RPL: Low-flow FlashScan photo duct detector with relay and housing, will replace FSD-751 RPP, See DN-6955. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector, wilireplace FAPT-751. See DN-6937. FAPT-751: Acclimate Plus low-profile multisensor detector. See DN-6833. FSH-751: FlashScan HARSH Hostile Area Smoke Head. See ON-6875. FSL751: FlashScan VIEW laser photo detector, will replace LPX-751. See DN-6886. LPX-751: Low-profile VIEW laser photo detector. See ON- 5306. B224RB: Low-profile relay base. B224B1: Isolator base for low-profile detectors. B71OLP: Low-profile base. Standard U.S. style. 8501: European-style, 4° (10.16 cm) base. B501BH: Sounder base, includes B501 base above. FMM-1: FlashScan monitor module. See ON-6 720. FDM-1: FlashScan dual monitor module. See DN-6720. FZM-1: FlashScan two-wire detector monitor module. See DN-6720. FMM-101: FlashScan miniature monitor module. See ON- 6720. FCM-1: FlashScan NAC control module. See DN-6 724. FRM-1: FlashScan relay module. See ON-6 724. NBG-12LX: Manual fire alarm station, addressable. See ON- 6726. ISO-X: Isolator module. See DN-2243. XPS-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XPS-R: FlashScan six-relay (Form-C) control module. See ON-6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. Page 6 or 8-ON-71 12:A2 '8/3107 I I OTHER OPTIONS I DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals; mount on NFS-320 chassis. See DN-6870. NCM-W: Network Communications Module, Wire. Order one I NCM per network node (CPU-640, CPU2-640, NCA, or NCA- 2). See DN-6861. NCM-F: Network Communications Module, Fiber. Order one NCM per network node (CPU-640, CPU2-640, NCA, or NCA- 2). See DN-6861. NCS5-W-ONYX: Network Control Station, Wire. UL-Listed graphics PC with mouse, 17" color flat-screen LCD monitor. Order as necessary for network systems. Each NCS con- sumes one of 103 network addresses. See DN-6868, ONYX I . DN-6869. NCS5-F-ONYX: Network Control Station, Fiber. UL-Listed graphics PC with mouse,, 17" color flat-screen LCD monitor. Order as necessary for network systems. Each NCS con- sumes one of 103 network addresses. See ONYX DN-6869. ONYXWORKS-NW: Workstation with NFN wire PC card. ONYX Works workstation GUI software and hardware package for NOTI•FIRE•NET. Includes NFN Gatevay (NFNGW-PC-W) I wire version. ONYXWORKS-NF: Workstation with NFN fiber PC card- ONYXWorks workstation GUI software and hardware package for NOTI•FIRE•NET. Includes NFN Gateway (NFNGW-PC-F) I .fiber version. ONVXWORKS-EW: Workstation with Echelon wire PC card ONYX Works workstation GUI software and hardware package for Building Systems Integration, WSSUP Workstation Super- visor. Includes Echelon® Gateway (ECH-GW-PC-W) wire ver- sion. NFN-GW-EM: NFN Gateway, embedded. VeriFire-TCD: VeriFire Tools CD-ROM. Contains program- ming software for the ONYX Series Includes local panel con- nection cable. Programming PC requires a serial port connection. See DN-6871. BAT Series: Batteries. NFS-320 utilizes two 12 volt, 18 to 200 AH batteries. This series of products replaces the previous PS Series. See DN-6933. NFS-LBB:Battery Box (required for batteries larger than 25 AH). NFS-LBBR: Same as above, but red. I I I I I I DN-71 12:A2 "8/3/07 - Page 7 of 8 I SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits ......................................1 Intelligent detectors .......................................................159 Addressable monitor/control modules............................159 Programmable internal hardware and output circuits ........4 Programmable software zones.........................................99 Special programming zone .............................................14 LCD annunciators per CPU-320/-320E ............................ 32 ACS annunciators per CPU-320/-320E ...................... 32 addresses x 64 points Specifications Primary input.poyer, CPU-320 board: 120 VAC, 50/60 Hz, 3.0 A. CPU-320E board: 220/240 VAC, 50160 Hz, 1.5 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply 'has a total of 6.0 A of available power. This is shared by all internal circuits. Standard notification circuits (4): 1.5 A each. Four-wire detector power: 1.25 A. Non-resettable regulated power outputs: 1.25 A each. Battery charger range: 18 AH —200 AH. Use separate cabi- net for batteries over 25 AH. Optional high-capacity (25 - 120 AH) battery charger: CHG-120 (see CHG-120 data sheet, DN-6040). Float-rate: 27.6 V. Cabinet Specifications NFS-320 cabinet dimensions: BACKBOX, OUTSIDE: 18.240" (46.33 cm) height. 5.77" (14.656 cm) deep. WITH DOOR 18.870° (47.93 cm) wide x 18.469° (46.911 cm) high x 5.817" (14.775 cm) deep. BACKBOX, INSIDE: 18.120" (46.025 cm) inner width, 5.175° (13.145 cm) inner depth. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful lie of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: file S635. IJLC Listed: file S635. FM Approved Standards The NFS-320 complies with the following UL Standards and NFPA 72 Fire Alarm Systems requirements: -. - UL 864 (Fire).- - UL 1076 (Burglary). - LOCAL (Automatic, Manual, Waterilow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). -REMOTE STATION (Automatic, Manual and Waterfiow) (requires 4XTMF). - PROPRIETARY (Automatic, Manual and Waterfiow). Not applicable for FM. - EMERGENCY VOICE/ALARM. Acclimate Plus"', HARSH'°", NOTI.FIRE.NET", and ONYXWorks°' are trademarks; and FlashScan®. NION®, NOTIFIER®. ONYX®, LiniNet®, VeriFire®. and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. Echelon® is a registered trademark of Echelon Corporation. IBM® is a registered trademark of IBM Corporation. 02007 by Honeywell International Inc. All lights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 I .1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. RM QUALITY SYSTEMS We cannot cover all specific applications or anticipate all requirements. MINEMIN All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. Page 8o18— DN-71 12:A2- 8/3/07 I I I I . CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . . LISTING SERVICE.: LISTING No. 7165-0028:243 . -Page I of 2 I CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NFS2-640 and NFS-320 fire alarm control units. Local, auxiliary, remote station I (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterflow and sprinkler supervisory services. Also suitable for releasing service. Model numbers may be followed by a URP suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System . I components: . . .. . CPU2-640, CPU-320 CPU Board NCA-2 Network Communication Annunciator I . NCM-W, -F Network Control Module LEM-320 . Loop Expander Module KDM-R2 Keyboard Display Module I . TM-4 . Transmitter Module KAPS-24 -. Power Supply CAB-4 Series Enclosure OP-lB Blank Panel • I . BMP-1 Blank Module ADP-413, -A4, -1, -2, DP-DlSP2 Dress Panels CHS2-M2 . . Chassis B100, 200, NFSLBB/LBBR Battery Boxes I . BP2-4 . Battery Dress Plates RPTW, -485W Repeater Wire RPT-F,-485F Repeater Fiber I RPT-FW Repeater Fiber/Wire SCS-8 Smoke Control .Station SCE-8 Smoke Control Expander SCS-8L Smoke Control Lamp Driver Station I . SCE-8L Smoke Control Expander Lamp NCS4-W-ONYX, NCS4-F-ONYXNetwork Control Station NCSS-W-ONYX, NCS5-F-ONYXNetwork Control Station FCPS-24S6, -24S8 Field Charger/Power Supply I . XPM-8L Transponder Monitor Modules PRN-6 Printer. NBG-I2LX . Addressable Manual Pull Station I NBG-I2LRA Agent Releasing Abort Station FZM-1, FMM-1, FMM-1 01 Monitor Modules FDM-1 Dual Monitor Module CRT-2 Display Terminal I ISO -X . .Isolator Module I . 04-02-2007 mt I I . I I I I... I I I I I. I I I I I I I INSTALLATION MARKING: APPROVAL: NOTE: Date Issued: DECEMBER 14, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshél Program Manager For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. This control unit meets the requirements of UL-864, 9th Edition Standard FTM-1 Control Module FRM-1 Relay Module FCM-1 Releasing Module DPI-232 Panel Interface RKS-S Remote Security Key Switch In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL Label Listed as fire alarm control units suitable for use in non-high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. Listing No. 7165-0028:243 Page 2 of 2 04-02-2007 mt n '. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. DN-6935:A • H-202 FSP.851 and FSP.851T NOTIFI ER® Intelligent Plug-In Photoeleótric Smoke Detectors with FlashScan® by Honeywell General . Notifier 851 Series intelligent plug-in smoke detectors with integral communication -provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously màni- . . tored and reported to the panel. Point ID capability all . each detector's address to be set with decade address . . switches, providing exact detector location for selective main- tenance when chamber contamination reaches an unaccept- able level. The FSP-851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke pro- . FSP-851 with B7IOLP base duced by a wide range of combustiàn sources. Dual electronic thermistors add 1350F (57°C) fixed-temperature thermal sens- ing on the FSP-851T. FSP-851 and FSP-851T detectors are --------. compatible with all Notifier intelligent Fire Alarm Control Pan- els (FACP) ( FlashScan® (U.S. Patent 5,539,389) is a communication pro tocol developed by Notifier engineering that greatly enhances - — the speed of communication between analog intelligent - devices Intelligent devices communicate in a grouped fash N. ion. If one of the devices in the group has new information, the .. panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five FSP-851T with B71 06P base times that of earlier designs. . . Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. FlashScan (NFS-640, NFS-3030) and classic CLIP sys- tems (AFP-100, AFP-200, AFP-300, AFP-400, NFS-640, AM2020/AFP1010, NFS-3030) compatible. Rotary, decimal addressing (1-99 on current classic sys- tems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (F!ashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against baOk pressure. Constructed of off-white Bayblend®, designed to commer-. cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Backward compatible. Specification Size: 2.1" (5.3cm) high x 4.1" (10.4cm) diameter installed in B501 base, 6.1" (15.5cm) diameter installed in B71OLP base. Shipping Weight: 5.20z. (147g). Operating Temperature: FSP-851, 0°C, to 49°C (32°F. to 120°F); FSP-851T, 0°C to 38°C (32°F to 100°F). Low temper- ature signal for FSP-851T at 45°F +1- 10°F (7.22°C +1- 5.54°C). - - UL Listed Velocity Range: 0-4000 ft/mm. (1219.2 rn/mm.), suitable for installation in ducts. Relative Humidity: 10%-930/o noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications, with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights .10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications referto NFPA 72. System Smoke Defector Application Guide, document A05-1003, is available at systemsensor.com FSP-851 and FSP-851T are listed for use in ducts,but they are NOT listed for use inside duct smoke detector housings. 'See Duct Application Smoke Detectors Guide, document A05- 1004, available at systemsensor.com, for details on pendant- mount applications. Address Dial on back of Detector ANNUNCIATOR Wiring Diagram OPTIONAL RETURN LOOP I ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. I Standby Current (max. avg.): 25OpA © 24VDC (with no communication enabled); 3601JA © 24VDC (one communica- tion every five minutes with LED enabled). I LED Current (max.): 6.5mA © 24VDC ('ON'). BASES AVAILABLE B71OLP: 6.1" (15.5cm) diameter. I . B501: 4.1" (10.4cm) diameter. B501 BH or B501 BHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw Terminals, up to 14AWG I (2.0mm2); Relay Type, Form-C; Rating, 2.OA 0 30VDC resis- tive, 0.3A 0 110VDC inductive, 1.OA 0 30VDC inductive; Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.2" (3.048cm). I . B224B1 Isolator Base: Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 12" (3.048cm); Maximum, 25 devices between .isolator bases. I Installation FSP-851 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- I out using a ladder. -. Mount base on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: I .. . 4.0" (10.16cm) square box. 3.5" (8.896m) or 4.0" (10.16cm) octagonal box. Single-gang box (except relay or Isolator base). With B501BH or 8501BHT base, use a 4.0° (10.16cm) I . square box. With B224RB or B224Bl base, use a 3.5" (8.89cm) octago- nal box, or a 4.0" (10.16cm) octagonal or square box. NOTE: 1) Because of inherent supervision provided by the SLC I loop, end-of-line resistors are not required. Wiring "Flaps" or branches are permitted for style 4 (Class "8") wiring. 2) When using relay or sounder bases, consult data sheet DN'2243 (ISO-X) I . for device limitations betwqen isolator modules and isolator bases. • Agency .Listings and Approvals. These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications I may not be listed by certain approval agencies, or listing may. be in process. Consult factory for latest listing status. .. UL Listed: S1 115 ULC Listed: CS915 (FSP-962A, FSP-851TA) I . MEA Listed: 225-02-E FM Approved I . CSFM: 7272-0028:206 Maryland State Fire Marshal: Permit #2122 BSMI:C1313066760036 o CCCF: Certif. #2004081801000017 (FSP-851T) Certif. #2004081801000016 (FSP-851) Lloyd's Register: 03/60011 II Page 2 of 3- DN-6935:A • 12128/06 I Product Line Information NOTE: Wsuffix indicates ULC listed model. .FSP-851:Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A:Same as FSP-851 but with ULC listing. FSP-8511:Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA:Same as FSP-851T but with ULC listing. BASES B71OLPBP:Standard U.S. low-profile base, pkg. of 10. B7IOLPA:Standard U.S. low-profile base, ULC listing. B501BP:Standard European flangeless base, pkg. of 10. B501A:Standard European flangeless base, ULC listing. B501BH(A):Sounder base, includes B501 (A) base. B501BHT(A):Same as B501BH(A), but includes temporal sounder. B224RB():lntelligent relay base. B224B1(A):lntelligent isolator base. Isolates SLC from loop shorts. STI 9609:High-profile, flush-mount, smoke detector guard, wire.' STI 9605:1-igh Profile, surface-mount, smoke detector guard, wire.' STI 9604:Flush-mount, heat detector guard, wire.' STI 9610:Surface-mount, heat detector guard, wire.* STI-8200-SS:Flush-mount stainless steel smoke detector guard (compatibility pending). STI-8230-SS- Surface mount stainless steel smoke detector guard (compatibility pending). 'For dimensions and additional information on STI Steel Web Stoppers, see data sheet DN-4936. I I I .. I I I I ACCESSORIES F11O:Retroflt replacement flange for older style bases. Con- veils old high profile base for use with FlashScan detectors. RA400Z(A):Remote LED annunciator. 3-32VDC. Fits U.S. single-gang electrical box. Supported by B71OLP(A) and B501 (A) bases only. SMK400:Surtace mounting kit provides for entry of surface wiring conduit For use with 8501 (A) base only. RMK400:Recessed mounting kit. For use with B501 (A) base only. SMB600:Surfacé mounting kit for use with B71OLP(A). BCK-200B:Black detector covers, box of 10. For use with FSP-851 only. M02-04-01:Test magnet. M02-09-00:Test magnet with telescope stick. XR2B:Detector removal tool. Allows Installation and/or removal of FlashScan Series detector heads from base in high ceiling installations. T55-127-000:Detector removal tool without pole. XP-4:Extension pole for XR2B. Comes in three 5-ft. sections. DETECTOR GUARDS NOTE. Some guards listed below may not be applicable to FPS models. SDG-773:Smoke detector guard; cover is 7.0" (17.78cm) squarex 3.0" (7.62cm) deep. This guard is mechanically com- patible with FSP-751. It is UL-compatibility listed with the FSP-851 (file UL S5515). STI 9601 :Low-profile , flush-mount smoke detector guard, wire.' STI 9602:Low-profile, surface-mount, smoke detector guard, wire. Nofifier@ and FlashScan® are registered trademarks of Honeywell Interna- tional Inc. Bayblend® is a registered trademark of Bayer Corporation. 02007 by Honeywell International inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. WTVA • We cannot cover all specific applications or anticipate all requirements. tuireiiri &rumeiun®c All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-6935:A • 128l06 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:206 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FSP-751, HPX-751, FSP-751 T, *FSH..751 ,1FAPT-751, *FAPT..851 *FSp 851 and *FSP51T photoelectric type smoke detectors. Models FSP-751T and *FSP..851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 1 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. *Models FSP-751, FSP75IT, *FAPT..751 *FAPT51 *FSP 851 and *FSP51T Models FSP451 and FSP-751T are suitable for open areas and inside. duct installation with air velocities between 04000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. *Model FSH-751 is suitable for open areas with air velocity between 0-400 fpm. . NOTE: 1. 'Combined with 7272-0028:208 I 2. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. I . . *Rev . 07-24-2002 BH .. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or >...' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! Program Manager I DN-6936:A • 11-211 FST-851 Series Intelligent Thermal (Heat) Detectors with FlashScan® ©NOTIFIER® hi HnnP/AIII Intelligent/Addressable Devices Notifier FST-851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously moni- tored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. FST-851 Series thermal detectors use an innovative thermistor sensing circuit to produce 135017/570C fixed-temperature (FST- 851) and rate-of-rise thermal detection (FST-851 A) in a low- profile package. FST-851H provides fixed high-temperature detection at 1900F1880C. These thermal detectors provide cost effective, intelligent property protection in a variety of applica- tions. FST-851 Series detectors are compatible with all Notifier intelligent Are Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851 A), 15°F (8.3°C) per minute. Factory preset at 135°F (570C); high-temperature model at 190°F (88°C). Addressable by device. FlashScan® (NFS-640, NFS-3030) and classic CLIP sys- tem (AFP-100, AFP-200, AFP-300, AFP-400, NFS-640, AFP1010, AM2020, NFS-3030, NFS2-3030) compatible. Rotary; decimal addressing (1 - 99 on current classic sys- tems, 1 - 159 on FlashScan® systems). Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Listed to UL 521. Backward-compatible. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. FST-851 Series in B7IOLP base Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. Remote LED output connection to optional RA400Z remote LED annunciator. Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400) base mounting kits. Specifications Size: 2.1 (5.3 cm) high x 4.1° (10.4 cm) diameter installed in B501 base, 6.1'(15.5 cm) diameter installed in B71OLP base. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 Series, FST-851 R: - 20°C to 38°C (-4°F to 100°F); FST-851 H: -20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93%noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (570C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (880C). ELECTRICAL SPECIFICATIONS: Voltage range: 15-32 volts DC peak. Standby current (max. avg.): 200 pA 0 24 VDC (without communication); 300 PA 0 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA 0 24 VDC ('ON"). Bases available: B71OLP: 6.1° (15.5 cm) diameter. B501: 4.1° (10.4 cm) diameter. B501BH or BSO1BHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). I REMOIEANNUNCIATOR - 11 j I1 ~TNVI ( V~, 6714wIr20I Wiring Diagram Address dial on back of detector I B224B1 Isolator Base: Dimensions: 6.2° (15.748 cm) x 1.2° (15.748 cm). Maximum: 25 devices between isolator bases. I See Note 2 under Installation. Applications I Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, — zoning, wiring, and special applications. Installation The FST Series plug-in intelligent thermal detector uses a sep- arate base to simplify installation, service, and maintenance. I Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5° (3.81 cm) deep. Suitable boxes include: I . 4.0" (10.16 cm) square box. 3.5° (8.89 cm) or 4.00 (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). . . With B501BH or B501BHT base, use a 4.0° (10.16 cm) I square box. With B224RB or B224Bl base, use a 3.5° (8.89 cm) or 4.0° (10.16 cm) octagonal box, or a 4.0° (10.16 cm) square box. NOTE: 1) Because of the inherent supervision provided by the I SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class °B wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations beM'een isolator modules and isolator bases. I Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications I . may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747 ULC Listed: CS630 (ML255)(FST-851A, FST-851HA, I . FST-851 RA) MEA Listed: 383-02-E I . • FM Approved - CSFM:7270-0028:196 BSMl: 61313066760025 CCCF: Certif. #2004081801000018 Coast Guam: 161.002/23/3 (AFP-200); 161.002127/3 I .U.S. (AFP1010/AM2020); 161.002142/1 (NFS-640) Lloyd's Register: 03/60011 I .. I. I I Page 2 of 3— 0N6936A • 1/11/07 H Product Line Information 'W 'suffix indicates ULC Listed model. FST-851 Series: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851 SeriesA: Same as FST-851 Series but with ULC List- ing. FST-851 R: Intelligent thermal detector with rate-of-rise feature. FST-851 RA: Same as FST-851 A but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851HA: Same as FST-851H but with ULC Listing. BASES: B71OLPBP: Standard U.S. low-profile base, pkg. of 10. B710LPA: Standard U.S. low-profile base, ULC Listing. B501 BP: Standard European flangeless base, pkg. of 10. B501 A: Standard European flangeless base, ULC Listing. B501 BH(A): Sounder base, includes B501 (A) base. 8501BHT(A): Same as B501BH(A), but includes temporal sounder. 8224RB(A): Intelligent relay base. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: -. Fl 10: Retrofit replacement flange for older style high profile bases. Converts bases for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S... single-gang electrical box. Supported by B71OLPBP(A) and B501 (A) bases only. SMK400: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit For use with B501 (A) base only. SMB600: Surface mounting kit for use with B710LPBP(A). BCK-200B: Black detector covers, box of 10. M02-04-01: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-000: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 54 sections. DETECTOR GUARDS: NOTE: Some guards listed below may not be applicable to FST Series. ST19601: Low-profile, flush-mount smoke detector guard, wire.' ST19602: Low-profile, surface-mount, smoke detector guard, wire.' ST19609: High-profile, flush-mount, smoke detector guard, wire.' 5T19605: High-profile, surface-mount, smoke detector guard, wire.' STI 9604: Flush-mount heat detector guard, wire.' STI 9610: Surface-mount heat detector guard, wire.' 'For dimensions and additional information on STI Steel Web Stoppers, see data sheet DN-4936. ST18200-SS: Flush-mount stainless steel smoke detector guard (compatibility pending). ST18230-SS: Surface-mount stainless steel smoke detector guard (compatibility pending). Nolifiei® and FlashScan® are registered trademarks of Honeywell Interna- tional Inc. Notifiet® and Bayblend@ is a registered trademark of Bayer Corp. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I I I I 'I I II This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 93M : I .1 We cannot cover all specific applications or anticipate all requirements. UIIINLHIIZIG & M11MINT111111111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 3013— DN-6936:A • 1/11/07 I Li LI CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:196 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FST-751, *..851 *..851R *..851H (fixed temperature) and FST-751R (fixed temperature with Rate-of-Rise). electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 1350 F fixed temperature for *Models FST-751, -751 R, -851, and -851 R *1900 F fixed temperature for Model FST-851 H INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances - and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501 or B71OLP base (CSFM Listing No. 7300- 0028:173) and separately listed compatable fire alarm control units. Refer to listee's Installation Instructions Manual for details. El *Rev. 2-04-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Electrical .Ratingè FOR B224RB, B224B1: ,. . Operating voltage; 15 to 32 VDC (powered by SIC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB 'only): short delay 55 to 90 msec; long delay"• 6 to 9 seconds: Reset time (132241113 only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (ULJCSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A © 30 VDC. FOR B5OIBH, B50IBH-2, B50IBHT, B501BHT-2: External supplyvoltage: 17 to 32 VDC. Standby current: 1.0 mA maximum. r Alarm current: 15 m maximum. Diameter: For B501: 4.1" (104 mm). For B224B1, B224RB, B7IOLP: 6.1" (155 mm). For B50IBH, B501BH-2, B50IBH1 - B50IBHT-2: 6.0" (152 mm). Wire gauge: for 8224B1, B224R6: 14, to 24 AWG For B7IOLP,B501, BSOIBH, B50IBH-2, B50IBHI B50IBHT-2: 12 to 18AWG - Temperature range:-Fôr B224B1, B224RB, B50IBH, B50IBH- 2, B5OIBH1 B50IBHT-2: 32°F to 120°F. (0°C to 49°C). For 8501 and B71OLP, 32°F to 150°F (0°C to 660C). Humidity range: 10% to 93% RH, non-condensing System temperature and humidity ranges: This system. meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F): and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ±2% it 32°C ± 2°C (89.6°F ± 1.1°F) per.ULC. However, the useful life of the system's standby The RMK400 can be used with drywall or .suspended ceilings. batteries and the electronic components may be adversely The aesthetically pleasing design can be used with standard affected by extreme temperature ranges and humidity. There- junction boxes - suitable for use with 4.0° (10.16 cm) octago- fore, it is recommended that this system and all peripherals be nal, 50 mm, and 60 mm junction boxes connected to flexible installed in an environment with a nominal room temperature of conduit. Note that junction boxes are not included in the kit. As to 27°C (60°F to 80°F). : an application example, with the B501 base, the'.RMK400 pro- vides a simple installation solution in applications that demand a lower-profile smoke detector. Specifications Agency Listiflgs and Approvals The listings and approvals below apply to intelligent bases as noted. 'In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. Listing information to be provided in upcoming edits. Consult panel manuals for- lists of compatible UL-Listed devices. All bases have been previously listed for use with various panels. Product Line Information INTELLIGENT BASES -. B501: Flangeless mounting base. . * 1350IA: Flangeless mounting base, ULC Listed. Maximum ripple voltage: 10% bf supply voltage. Startup capacitance: 200 pF. Set time: for B50IBH and B50IBH1 6 to 15 seconds. For B50IBH-2 and B501BHT-2, 0.75 to 5.7 seconds: Sound output: greater than 90 dBA measured in anechoic room at 10 feet (3.048 m), 24 volts. 85 dBA minimum in UL reverberant room. ' ReceSsed Mounting Kit DN-60054:A° H-320 Intelligent Bases.KOTI '• F ill B224B1(A), B224RB(A), 01501 (A), B5OIBH(A), . - 8501 BH-2(A), BSOI BHT(A), 8501 BHT-2(A), B7IOLP(A), Mounting Kits, and Accessories by Honeywell dressabie uevuces41 . ,. General . . • Intelligent FlashScan® and CUP mounting bases and kits pro J i vide a variety of ways to install NOTIFIER detectors in any appli- cation. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selection (see Junction Box Selection Guide) Across this product line detec- tors plug in easily to the base with SEMS screws: and models Flange Mounting Base Relay Base employ various 12 to 22 AWG wire ranges. . , less Relay, isolator, and sounder bases can be used to meet local r code requirements Relay bases provide one Form C contact relay for control of auxiliary functions such as door closure and elevator recall Isolator bases allow loops to continue to operate ...-----'-. under fault conditions and automatically restore when the fault is removed Sounder bases are available in temporal and non- temporal pattern versions depending on whether the signal is to Recessed Mounting be used for evacuation purposes. . -Flanged Mounting Base The RMK400 recessed mounting kit provides the most aes- thetically pleasing installation Surface mounting boxes are available when flush mounting isn't possible. DN-60054:A. 11/30/06;— Page 1 of 2, B7IOLP: Flanged mounting base. B7IOLPA: Flanged mounting base, ULC UL Listed. B50IBH: Standard sounder base. B501 BHA: Standard sounder base, ULC Listed. B501 BHT: Temporal tone sounder base. B501 BHTA: Temporal tone sounder base, ULC Listed. B50IBH-2: Standard sounder base, UL 864 9th edition compli- ant. B501 BH-2A: Standard sounder base, UL 864 9th edition corn- pliant,.ULC Listed. B50IBHT-2: Temporal tone sounder base, UL 864 9th edition compliant. B501 BHT-2A: Temporal tone sounder base, UL 864 9th edition compliant, ULC Listed. B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. B224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES RMK400: Recessed mounting kit. SMK400: Surface mounting kit, flangeless. SMB600: Surface mounting kit, flanged. FIIO: Retrofit flange for B501 B, B524. RA400Z: Remote LED annunciator. RA400ZA: Remote LED annunciator, ULC Listed. M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool (T55-127-000 included). XP-4: Extension pole for XR2B (5 to 15 f111.524 to 4.572 m). T55-127-000: Detector removal head. BCK-200B: Black detector kit. Junction Box Selection Guide - Base Models Single- Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B501 No Yes No No Yes Yes Yes Yes No B7IOLP Yes. Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes B50IBH, B501BH-2 No No No Yes No No No No No B501 BHT, B501 BHT-2 No No No Yes No No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. 02006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. d We cannot cover all specific applications or anticipate all requirements. MRINEMINI &MANUMCIIIUNC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifler.com Page 2 of 2— DN-60054:A • 11/30/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:173 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models BX50I, 13610LP, B612LP, B6I4LP, B6I6LP and B71OLP detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: ' In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the aUthority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. XLF: 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager June 13, 2005 DN-6726 • H-240 NOTIFIER® by Honeywell NBG-12LX Addressable Manual Pull Station with FlashScan® Section: Intelligent/Addressable Devices Patented, U.S. Patent No. 0428,351; 6,380,846 U.S. Patent Pending: 091686,286 C©US State Fire MEA California Marshal 7150-0028:199 GENERAL I The NOTIFIER NBG-12LX is a state-of-the-art, dual-ac- tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG-12LX I is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. - FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. ! Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. - Up to 99 14BG-1 2LX stations per loop on classic protocol systems. Up to 159 NBG-12LX stations per loop on FlashScan® protocol systems. Dual-color LED blinks green to indicate normal on FlashScan® systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from FlashScan® and NOTIFIER® are registered trademarks of Hon- eywell International INC. LEXAN® is a registered trademark of ,I....;A,,,... j ,'...__....... LISTED S692 U.S. Coast Guard *> 161.002/23/3 (AFP-200) APPROVED BSMI 93/60141 (E3) 02/6007 C1313066760047 The NBG-12LX Addressable Manual Pull Station the bottom of the station. To reset the station, simply un- lock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address set- tings (1 - 159 on FlashScan® systems, 1 - 99 on CLIP _.. -- --..-.-.-.-..---.--..,. Systems). This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484.7118 • • tdq hl NOTI Fl E R ENGINEEIIllt8 8 MNOFACTh1Ir8 by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS Back of station without door. flI JIiiYLif•i NBG-12LX Dual-action addressable pull station. Includes key locking feature. SB-10 Surface backbox. SR-I/O Indoor/outdoor surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface backbox. If the NBG-12LX is being semi- flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mount- ing with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). -. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 375 MA. ARCHITECTURAL/ ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surfiàe mounting on matching backbox SB-i 0; or semi-flush mount- ing on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the limits defined by the-Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. 44 Terminal Connections 1 SLC(—) 2 SLC (i-) C Detail of .<=fl BREAKAWAY TAB* 15 0 ADDRESS - 13 2 11 LOOP LED "Remove tab to select addresses above 99 (FlashScan® systems only). Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 - DN-26 .06/13/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484*7161 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-I2LAO, .NBG-12LAOB, NBG- 12-1-0, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-I2WP, NBG-12LWP, NBG- 12L, NBG-12LX, NBG-I2LA, NBG-I2PS, NBG-I2LSP, NBG-I2LPS, NBG-I2LPSP, NBG- 12SP, NOT-BG12LX, and NBG-I2LXSP fire alarm pull boxes. All units except Model NBG 12S are dual action pull stations. Models NBG-1 2LR and NBG-1 2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-I21-W, NBG-12W, NBG-I2LWP,•NBG-I2LAO, NBG-121-0, NBG- I2LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. Rev. 1-06-2006 jaw This listinb is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 I Authorized By: I MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager 0 NOTIFIER® GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor mod- ules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1). FIVIM-1 - is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style 0) or Class B (Style B) circuit of dry-contact input de- vices. FMM-101 - is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) 0) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single-gang box behind the device it's monitoring. FZM.1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit.. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- .vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 —159 on FlashScan® sys-. tems, 01 - 99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (I DC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. August 23, 2004 DN-6720 H-220 FMM-1, FMM-1O1, FZM-1, FDM-1 Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices <9> LISTED CS669 APPROVED S635 U.S. Coast Guard Al MM-1/-101. 161.002/23/3 (AFP-200: FZM-1) p 161.002/42/1 California (NFS-640: FMM-1/-101) State Fire Marshal 7300-0028:202 detail of FDM-1 - note "ones" addresses are 0, 2, 4, 6, 8 only _I52'4 I 18 I II • 6789 10 0 I TENS t4 2 J6 : ONES lt.00P 1 ADDRESS FMM.1.Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style 0 circuit. Maximum IDC loop length is 2,500 ftJ762 m (20 ohms maximum). 93/60141 (E3) (FMM-1/-101. FZM-1) 94!60004/E2 (AFP200: except FDM-1) 02/60007 (NFS-640: FDM-1) MEA 143-01-E (FDM-1) 317-01-E (FMM-1/-101) 345-02-E (FMM-1/-1O1) 457-99-E (FZM-1, FMM-1/-101) 447-99-E FMM-1 and FZM-1 NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information Up-to-date and accurate. We cannot cover all specific applications IS09001 or anticipate all requirements. All specifications are subject to change without notice. ZTA =6 Z at a • For more information, contact NOTIFIER. Phone: (203) 484.7161 FAX: (203) 484-7118 NOTI F I E R 12 Clintonville Road. Northford, Connecticut 06472 QUALITY SYSTEMS FMM-1 Operation - Each FMM-1 uses one of 159 avail- able module addresses on an SIC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (lDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FMM.1O1 MINI MONITOR MODULE built-in type identification automatically identifies this de- vice as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. ° High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 —99 on CLIP systems. 1415 0 1 I_ADDRESS 2 13 21 11 4 LOOP I l 9 87 61 1.98 76 m I TENS ONES u ii Il oil Lu .__J ...11 iI - 0 e Ii II The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. FMM-101 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry- contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47 ohm End-of- Line Resistor (provided) terminates the circuit. FM M-1 01 Operation - Each FMM-101 uses one of 159 available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (lDC) FMM-1 01 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x 0.5° (1.270 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises lOG wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. ° Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 —99 on CLIP systems. ° LED flashes during normal operation (this is a program- mable option). ° LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be 'UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Ini- tiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (pro- vided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style 0 application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to-current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 255 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 018— DN-6720 • 08/23/04 1*1 RE CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Face Plate for FMM-1, FZM-1, and FDM-1 MOUNTING DIAGRAMS for slundard-sized modules DN-6720 • 08/23/04 - Page 3 of 6 FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecu- tive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (Style Y IDC circuits ONLY. Class A (Style Z) IDC circuits are NOT supported in any application. FDlVl-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°t). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) vide x 2.125" (5.398 cm) deep. FDM-1 Automatic Addressing -The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address "56°, then it will automatically assign itself to ad- dresses "56° and "57°. NOTE: "ones" addresses on the FDM-1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. /Ai2iON! Avoid duplicating addresses on the system. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a stan- dard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are pro- vided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. SMB500 Optional surface-mount backbox. ARCHITECTS'/ENGINEERS'. SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from NOTIFIER. I- IR .' . ' - FROM Pane! Device (+)or Previous Communication Line 32.VDC maximum. Twisted-pair is recommended. - All wiring shown is supervised and power limited. Connect modules to listed compatible NOTIFIER control panels only. WIRING DIAGRAMS The following wiring diagrams are included: FDM-1, typical dual two-wire Style B initiating device circuit configuration. 17111111111-11011, typical two-wire Style B initiating device circuit configuration. FMNI-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM-1, typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1 interface two-wire conventional detectors, NFPA Style D. FRM-1, relay control module used to disconnect a power supply. ) WIRING DIAGRAM: J Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H) TO Next - each power-limited to- Device 1+) I13'i6f'n,v I ia,-' •• V S1 MONITOR I 47KEOL [[[]j[7 F1MODULE R Resistor. ELR-47K I • T 47KEOL . 6 3 Resistor . I 4 ELR-47K . I- LOOP ADDRESS ••S o9 ANY NUMBER of UL Listed contact closure devices may be used. 6822wir1.w7W DO NOT MIX fire alarm Initiating, supervisory, or security devices on the same circuit. I - Install contact closure devices pdr manufacturer's installation instructions. TO 10- NEXT DEVICE I . BLACK _j1RED UL LISTED Compatible H FMMIOI p Control 5 Panel 6789 112 78 3 20 13 101514 10 H I . VIOLEThI 14YELLOW 47K EOL INCLUDED Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. 672041,1.wml Page 4 of 6 - DN.6720 -08/23/04 Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. TO Next Device (+ FROM Panel NITO1 or Previous Device Initiating Device Circuit (!DC) I NFPA Style B, power limited: Commun ication Line f:32 230 pAmax.@12VDCmax. VDC maximum. Twisted-pair is 47K EOL recommended. Resistor I + I I + I r__116 ELR-47K ----- Communication Loss LOOP i0o (optional connection for panels which support this feature) FUTURE FEATURE 6720w1r2.wmf V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next Device Panel or Previous MONITOR Device MODULE Communication ication Line 32 VOC maximum. Twisted-pair is recommended. EOL Resistor Is internal at terminals 8 & 9 V Communication Loss LOOP °'ADDRM (optional connection for panels which support this feature) FUTURE FEATURE 6720wfr3.wmf V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). Initiating Device Circuit (!D TO Next Device (—) FROM Panel or Previous NFPA Style B, power limited: MONITOR Device 230 iA max @ 12 VDC max. MODULE f 32 Line 14K Series Resistor VDC maximum. 7 TENS ommunication —wisted-pair is + recommended. 47K EOL Resistor 06 Communication Loss ELR-47K Loop (optional connection for panels 0 which support this feature) FUTURE FEATURE 6720w14.wmr DN-6720 • 08/23/04 — Page 5 of 6 Connect modules to listed compatible control panels only. yf .1 1 Terminal wiring must be power limited. 'I1J1 DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. ' : DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. THIS PAGE: Detectors must be UL listed compatible with module. Install detectors per manufacturers' installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay control module can be used to switch power from a standard power supply; see Fig. 7 below. V Fig. 6 FZM-1: Interface two-wire conventional detectors, NFPA Style B. TO Next (+ (—) FROM Panel (+) Device or Previous INTERFACE Device MODULE d Communication Line 32 VDC maximum. Twisted-pair is 9 0 81 — recommended. 3.9K EOL 7 'us . 2 I 6 + Listed Batteiy Backup Resistor 5 4 + switched DC (included) ons power supply. A2143-10 LOOP ADDRESS Optional Branch Circuit TO Next Interface Module 6720wfr5.wmt Module supervises supply - voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. TO Next FROM Panel Device (+ or Previous Device INTERFACE ication Line r32 MODULE aximum. ir is recomm 3.91K EOL 3ea= Listed Battery Backup t terminals 8 & 9 switched DC power supply. Branch Circuit TO Next Interface Module 72Owlt&wml Module supervises supply voltage and detector loop. V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. TO Next (—) FROM Pane! Device ,QcXc:(,Iii-I:: or Previous Device DC POWER SUPPLY () Listed for Fire (—) Protection with Battery Backup (—) (+) 4 II_ I CONTROL ibJ \ Communication Line 32 VDC maximum. — Twisted-pair is recommended. Page 6 of 6 — DN-6720 • 06/23104 csco9 U 6720wk7.wmr Li CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, *nM..1 monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational consideations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manneracceptabIe to the authority having jurisdiction. MARKING: -. Listee's name, product number and UL label. APPROVAL: Listed as control unit.accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640 (CSFM Listing Nos. 7165-0028:214 and 7170-0028:216), NFS-3030, NFS2-3030(CSFM Listing Nos. 7165-0028:224 and 7170-0028:223) Fire Alarm Control Units. LI fl Rev. 07-12-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet,. installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! Program Manager DN-6955:A H-215 FSD.751PL(A), FS01.75IRPL(A) I Intelligent Low-Flow Photoelectric - I I I. I I I: .1 I nra N OTIFI ER® uuct moe Detectors with Flashscan® Honeywell General . . NOTIFIER FSD 751PL(A) and FSD 751RPL(A) Intelligent Pho toélectric Smoke Duct Detectors provide low-flow technology that enables duct smoke detection throughout a broad range of airflow environments in HVAC applications The low flow tech- nology can detect smoke at air speed velocities of 100 feet per minute (0.5 mlsec) or greater, while continuing the same reliable performance to 4,000 feet per minute (20.32 mlsec) The intelli / - gent low flow duct detectors sample air currents passing through a duct and gives dependable performance for shutdown 5239BpflI Pg &. of fans blowers and air conditioning systems preventing the spread of toxic smoke an fire gases through the protected area.,\.....,. _,'- .-'- — .FSD-751PL(A) and FSD-751RPL(A) are compatible with all . FSD-751PL NOTIFIER. addressable panels. FSD'iSlPL(A) and FSD- 751 RPL(A) provide a remote alarm output for use with auxiliary . . . . . ., devices, such as the RA400Z(A) remote LED annunciator, as well as remote test capability with the RTS45I(A) or . .j . RTS451 KEY(A) Remote Test Stations. . Traditional panels support addresses of 0 — 99 The Flash - Scan® protocol supports addresses of 0— 159 The patented _ 4- •' - , FlashScan communication protocol was developed by NOTI i FIER Engineering, it greatly enhances the speed of communica- tion between analog intelligent devices and the Notifier control 52398po panel Intelligent devices communicate in a grouped fashion If, \' one of the devices within the group has new information the panel stops the group poll and concentrates on single points. . FSD75IRPL The net effect is response speed greater than five times that of earlier 3242a4z.jpg - 3242fls4.jpg 32421ceyjpg Applications 5 Duct smoke detectors have specific limitations they are NOT a substitute for open area smoke detectors I —i ., NOT substitute for early warning detection \ ' It. NOT replacement for a building's regular fire detection sys- tem. Please call NOTIFIER for a copy of System Sensors application guide, Proper Use of Smoke Detectors in Duct Applications, (A05-1004-00). - . RA400Z RTS45I RTS45IKEY - Features . duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.31 mth. Flexible conduit-is recommended for the last Air velocity rating from 100 to 4,000 feet per minute (0.5 to -foot (30.48 cm) of conduit; solid conduit connections may be 20.32 mlsec). - - - - used if desired. - -. Patented telescopic sampling tube. - - Smoke detectors and alarm system control panels have specifi- Easily accessible code wheels for addressing, detector. - cations for Signaling Line Circuit (SLC) wiring. Consult the con- Outside mounting tabs. - trol panel specifications for wiring requirements before wiring Mounts to round or rectangular ducts from 1' to 12' 10 3t0 3 7 .. the detector loop. The FSD-751PL(A)- and FSD-751 RPL(A) - g ' detectors are designed for ease of wiring; their housing provides meters) wide. - a terminal strip with clamping plates. Transparent cover for convenient visual inspection. . . - LED Features: If programmed with the system -control panel, ' - . two LEDs on each duct smoke detector light to provide local vis- ible indication. - Refer to installation manuals for control panel and duct detector ' Programming specifications/requirements for intelligent for detailed information or to install equipment. Installation man- system control panels: The number of devices that can have uals for detectors: 1561978-003R for FSD-751 PL(A), 156-1979- their LEDs programmed to illuminate is limited by-the features of 004R for FSD-751 RPL(A). - the panel and the individual devices. The actual number of Wiring For signal wiring (the wiring between detectors or from devices is determined by the control panel and its ability to sup- detectors to auxiliary devices), it is recommended that single ply, LED current. Refer to the control panel installation manual conductor wire be no smaller than 18 AWG (0.821 mm2). The for details. - - - - , . - • . ' - • DN-6955:A • 12/29/06 — Page 1 of 4 / Detector TeMinals 682Iyb2.wmf FSD-751PL(A) Duct Smoke Detector with RTS45I(A)I RTS45I KEY(A). COMMON TEST 4 ® NOTE: For RTS451(A), Terminal 3 is not used. RTS45I(A) does not have a Terminal Field-Installed 6. For RTS45IKEY(A), Terminals 3 and 6 are not used. \1IPER LED RESET RTS45I/RTS45I KEY N CD 41 It, 3 ,0 00 0 0 Detector Terminals Wiring Diagrams for FSD-751PL(A) COMMUNICATION LINE '—.... —Ii — — — kW4 , • ._1 — a. HE — — — —MAI I 4! — — — — 'II . Loop.______ in Loop I st Detector 2nd Detector :n Loop FSD-751PL(A) Duct Smoke Detector using a UL or ULC Listed control panel. UL Listed Control Panel 682I.l.wmt 4 FSD-751PL(A) Duct Smoke Detector with an optional RA400Z(A). Inlet Tube Selection Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5(A) 2 to 4 feet (0.6096 to 1.2192 m) ST-3(A) 4 to 8 feet (1.2192 to 2.4384 m) ST-5(A) 8 to 12 feet (2.4384 to 3.6576 m) ST-10(A) *Inlet tube is required and must be purchased separately. Order One inlet tube for each duct smoke detector ordered. Page 2 of 4— DN-6955:A • 12/29/06 Wiring Diagrams for FSD-751 RPL(A) FSD-75IRPL(A) Duct Smoke Detector using a UL-Listed control panel: ----------- I flfl.JJ CI 13 UL-LISTED - - CONTROL PANEL JI JUMPER 1ST DETECTOR J1 JUMPER 2ND DETECTOR. IN LOOP IN-LOOP NOTE: 1) Jumper JI shunt must be installed for 2-W applications. JI shunt must be removed for power PCB supervision. Note that removal of shunt without adding external power will prevent communications to the panel over the SLC. 2) External power of 24 VACIDC or 120t220 VAC must be connected in order to power all remote horn or strobe accessories. COMMUNICATION LINE FSD-75IRPL(A) Duct Smoke Detector with an optional RA400Z(A): RA400Z MR min 00 NOT BREAK TAB 7 7F] ONRA400Z a 000 0 5 = Alarm Signal 7 = Aux. Power (-) i FSD-75IRPL(A) Duct Smoke Detector with an optional PA400: I I ••13o[_ LEI I II = 0rJI p 5 = Alarm Signal 7 = Aux. Power (—) FSD-751 RPL(A) Duct Smoke Detector with RTS45I(A)!RTS45I KEY(A): RTS451/ RTS451KEY r_-o ALARM SIGNAL NOT USED ALARM SIGNAL Of — Q NOT USED - AUX. POWER (-) - C)- <1) REFERENCE TEST — kT1-1 TEST 3 5.../ SWITCH TEST- C')- — FOR RTS451, TERMINAL 3 IS NOT USED. (RTS451 DOES NOT HAVE A TERMINAL 6.) FOR RTS451KEY, TERMINALS 3 AND 6 ARE NOT USED. 7OO6w4.wmf DN-6955:A • 12/29/06 - Page 3 of 4 I I II I I : Product Line Information NOTE: "A" model suffix is for Canadian models. FSD-751PL: Addressable low-flow duct detector housing with photoelectric smoke detector. FSD-751PLA: Same as above with ULC listing. FSD-751RPL: Addressable low-flow duct detector housing with photoelectric smoke detector with DPOT relay. FSD-751RPLA: Same as above with ULC listing. A5053FS: Replacement photoelectric sensor board. A5067: Replacement power board (without relay). A5060: Replacement power board (with relay). ST-1.5(A): Metal sampling tube, duct widths 1' to 2' (see Inlet Tube Selection table on page 2 for metric lengths). ST-3(A): Metal sampling tube, duct widths 2' to 4'. ST-5(A): Metal sampling tube, duct widths 4' to 8'. ST-10(A): Metal sampling tube, duct widths 8' to 12'. RA400Z(A): Remote annunciator alarm LED. RTS46I(A): Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS45IKEY(A): Key-activated remote test station. F36-09-11: Replacement filters. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. S08-39-01: Replacement photo insect screen. P48-61-00: Replacement end cap for plastic sampling tube. P48-21-00: Replacement end cap for metal sampling tube. T80-71-00: Replacement plastic sampling tube. Specifications FOR FSD-751PL(A) Operating voltage range: 15 to 30 VDC. Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). Operating humidity range: 10% to 93% relative humidity (non- condensing). Storage temperature range: —22°F to +158°F (-30°C to +70°C). Duct air velocity: 100 to 4,000 feet/mm (0.5 to 20.32 m/s). Shipping weight: 3.35 lbs. (1.5 kg). Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x 2.75° (7 cm) deep. FSD-751 PL(A) accessory current loads @24 VDC: RA400Z(A): 0 mA standby, 10 mA maximum in alarm. RTS45I(A) and RTS45IKEY(A): 0 mA standby, 7.5 mA maxi- mum in alarm. FORFSD-75IRPL(A) Operating voltage range: 20 to 30 VDC, 24 VACNDC, 120/ 240 VAC auxiliary power (requires a separate auxiliary source). Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). Operating humidity range: 10% to 93% relative humidity (non- condensing). Storage temperature range: —22°F to +158°F (-30°C to +70°C). Duct air velocity: 100 to 4,000 feet/mm (0.5 to 20.32 m/s). Shipping weight: 3.90 lbs. (1.8 kg). Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x 2.75" (7 cm) deep. FSD-75IRPL(A) CONTACT RATINGS Alarm auxiliary contacts (DPDT): 10 A @ 30 VDC; 10 A @ 277 VAC (0.75 power factor); 240 VA @ 249 VAC (0.4 power factor); 1/8 HP © 120 VAC; 1/4 HP @ 240 VAC. Minimum switching current for auxiliary contact must be 100 mA DC minimum @5 VDC. Supervisory contact (SPST): 2.0 A © 30 VDC (resistive). FSD-75IRPL(A) accessory current toads @ 24 VDC: PA400: refer to PA400 data sheet DN-2405. RA400Z(A): 0 mA standby, 12 mA maximum in alarm. RTS45I(A)and RTS45IKEY(A): 0 mA standby, 10 mA maximum in alarm. FSD-75IRPL(A) CURRENT REQUIREMENTS (USING NO ACCESSORIES) 20-30 VDC power supply voltage: 26 mA maximum standby current; 87 mA maximum alarm current; 3 to 10 second alarm response time; 2 second power-up time. - 24 VAC, 50160 Hz power supply voltage: 65 mA RMS maxi- mum standby current; 182 mA RMS maximum alarm current; 3 to 10 second alarm respoAse time; 2 second power-up time. 120 VAC, 50160 Hz power supply voltage: 44 mA RMS maxi- mum standby current; 52 mA RMS maximum alarm current; 3 to 10 second alarm response time; 2 second power-up time. 2201240 VAC, 50160 Hz power supply voltage: 25 mA RMS maximum standby current; 30 mA RMS maximum alarm current; 3 to 10 second alarm response time; 2 second power-up time. Agency Listings and Approvals The listings and approvals below apply to FSD-751PL(A) and FSD-751 RPL(A) Intelligent Low-Flow Photoelectric Smoke Duct Detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ° UL Listed: file S1115 (FSD-751PL, FSD-75IRPL). ° ULC Listed: file S115 (FSD-751PLA, FSD-75IRPLA). ° CSFM approved: file 3240-0028:205. ° FM approved. MEA approved: file 384-02-E. ° Maryland State Fire Marshal approved: Permit #2127. FlashScan®, NOTIFIERO and System SensorZ are registered trademarks of Honeywell International Inc. 02006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. - • We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. ' For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifler.com Page 4 of 4— DN-6955A • 12/29/06 .1 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 3240-0028:205 Page 1 of I CATEGORY: Duct Smoke Detector Housing/Base I. LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact Lawrence Flood (203) 484-1200 FAX (203) 282-7309 DESIGN: Models FSD-751 P1 -751 PL, -751 RP, and -751 RPL duct smoke detectors. Units consist of an enclosure, electrical components, sampling and exhaust tubes, and listed photoelectric smoke detector sensor. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15 to 32 VD C' INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner a&eptable to the authority having jurisdiction. MARKING: • Listee' name, model number, electrical and air velocity rating and UL label. I APPROVAL: Listed as duct smoke detectors for use with separately listed compatible fire alarm control units. *Models FSD-751 PL and -751 RPL are suitable for use in ducts where air velocity varies between 100 and 4000 fpm. *Models FSD-751P and -751RP are suitable for use in ducts I where air velocity varies between 500 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. 13 I *Corrected 12-03-03 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation I - criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. - Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 I Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager (0 NOTIFIER® GENERAL FCM-1 Control Module - The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressability al- lows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 Relay Module - The FRM-1 Addressable Re- lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScan® sys- tems only. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 forFlashScan®, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FlashScan® is a registered trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Elec- tric Company. April 5, 2004 DN-6724• H-230 FCM and FRM Series Control and Relay Modules With FlashScan® Section: Intelligent/Addressable Devices California State Fire Marshal 7300-0028:202 LISTED CS669 S3705 MARYLAND lvi EA State Fire Marshal Permit #2020 457-99-E . . APPROVED (See wiring diagram Fig. 5 for FRM-1) FRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four- wire smoke detector power. CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM provides two Form-C dry contacts that switch together. OPERATION Each FCM or FRM uses one of 159 possible module ad- dresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit NOTIFIER® is a Honeywell company. This document is not Intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 1111191101111ING & MANUlC1VJlNG NOTI Fl E R 12 Clintonville Road, Northiord. Connecticut 06472 QUALITY SYSTEMS DN-6724 • 04/05/04 - Page 1 of 4 MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT Page 2 of 4 - ON-6724 • 04105/04 I I (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnec- tion of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communica- tion loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. SPECIFICATIONS for FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 3'50 pA direct poll (CLIP mode), 375 pA group poll (FlashScan® mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL- relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. SPECIFICATIONS for FRM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (FlashScan® mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS for boib FCM and FRM models Load Description Maximum Application Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 1 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (hR = 5 ms) Coded 30 VDC 0.5 A Inductive (LIR = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 1125 VAC 0.5 A PRODUCT LINE INFORMATION FCM-1 Intelligent Addressable Control Module. FRM-1 . Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) opera- tion of speakers. SMB500 Optional Surface-Mount Backbox. cB500 Control Module Barrier - required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. M Nil I. 1 fl L I.. I fl L I I 1 The Face Plate 1j CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Y WIRING DIAGRAMS The following wiring diagrams are provided: FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. FCM-1: Typical wiring for speaker supervision and switching. NFPA Style V. FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. FRM-1: Relay module wiring diagram. I ....V Fig.. I FCM-1: Typical notification appliance circuit configuration, NFPA Style V. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. U . Module polarities are shown in alarm. — Communication Line 32 VDC max. Refer to panel documentation for TO Next Device cable required. FROM Panel U - CONTROL (+) or Previous Device MODULE 24 VDC Circuit 47K EOL 0 / DO NOTLOOP wire I Resistor ELR-47K o 8 — I on terminals 3 & 4. Break wire to provide () H - 7 rtis 2 + supervision of connections. (+) 24VDC LOOP POWER U 0 SUPPLY Power Supply: UL listed Isolated, regulated, U EOL Relay TO NEXTcontrol module or EOL Relay. power-limited per NFPA 70. shown . ONE RELAY REQUIRED for each circuit. Some rjanlml nnI have Ihaa RELAY BUILT TIM Listed for fire protection 4 I with battery backup. and do not require external wiring. 24 VDC coil A77-716B Refer to the NOTIFIER manual. - V Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Refer to panel documentation for TO Next of cable required jJ1 FROM Panel Device or Previous JRCONTROLP. EOL Resistor is internal at Cb terminals 8 _L MODULE 80 1 7 TENS 3kz I OOP A0DIESS1 0 00 (+) (+) UL listed I_ii_1 E OL Relay I TO NEXT control module or EOL Relay. shown L1 ONE RELAY REQUIRED for each circuit. energized I Some control panels have the RELAY BUILT IN 24 VDC coil and do not require external wiring. A77-716B Refer to the NOTIFIER manual. Device 4 VDC Circuit /DO NOT LOOP wire on terminals 3 & 4. — Break wire to provide supervision of connections. ThEffVDC POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection with battery backup. DN-6724 • 04/05/04 - Page 3 of 4 RELAY COMMON 2 NORMALLY CLOSED 2 NORMALLY OPEN 2 RELAY COMMON 1 NORMALLY CLOSED 1 V Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style V. Connect modules to Listed compatible Refer to panel documentation NOTIFIER control panels only Communication Line for type of cable required. All wiring shown is supervised. TO Next Device 32 VDC max - FROM Panel Wires n ust be supervised per NFPA. CONTROL (+) or Previous Device Module polarities are shown in alarm. MODULE Audio Circuit. DO NOTLOOP wire 47KEOL Resistor on terminals 3 & 4. Break wire to ensure ELR.47K supervision of connections. AUDIO AMPLIFIER 70.7 VRMS max. Use only models AA-30, AA-100, or AA-120. Amplifier must provide Speaker Switching Circuit: NFPA SE TO Next W Control Module wiring supervision per NFPA. SUPERVISION Speakers must be listed for lire. protection. Last module must return J Refer to the Relay contact Rating tabl'e for maximum load, wires for supervision. - 6724w3.wmf V' Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised. Refer to panel documentation Wires must be supervised per NFPA. TO Next - Communication Line for type of cable required. 32 VDC max Module polarities are shown in alarm Device - FROM Panel CONTROL (+) or Previous Device EOL Resistor is internal at terminals 8 &9. Bypass Capacitors:' A2143-20, 1000f, c? MODULE Audio Circuit. 16 V, non-polarized, 10 pA leakage. DO NOT LOOP wire on terminals 3 & 4. Break wire to ensure supervision of connections 3 S o 4 AU DIO AMPLIFIER A 1410 ONES 70.7 YRMS max LOOP AODISS Use only models M-30, AA-100, cir AA-120. (+ . I Aolifier must provide I V V WIrijSU[On per NFPA. Speaker Switching Circuit: NFPA STYLE X TO Next Control Module I SUPER WSION Speakers must be listed for tire protection. Last module must return . 6724W,4wmf Refer to the Relay Contact Rating table for maximum load, wires for supervision. NOTE regarding AUDIO AMPLIFIER in Figures 3 & 4 above: 1) Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailed information. I-' I TO Next Device RELAY ro MODULE 0 90°LI 84 7lI 2[ 6—' 3 El 5--fl--4( NORMALLY ADDRESS 0 00 7245.wmf OPEN 1 Page 4 of 4 - DN-6724 • 04/05/04 - FROM Panel (+) or Previous Device un i ca ti on L ine Communication Line : Refer to panel documentation 32VDC maximum. for type of cable required. 4 Fig. 5 FRM-1: Relay module wiring diagram. Connect modules to Listed compatible NOTIFIER control panels only. Module does NOT supervise controlled circuits. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-I, FMM-101, FZM-1, FSM-101, FDM-1, *RM..1 monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation intructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640 (CSFM Listing Nos. 7165-0028:214 and 7170-0028:216), NFS-3030, NFS2-3030 (CSFM Listing Nos. 7165-0028:224 and 7170-0028:223) Fire Alarm Control Units. *Rev. 07-12-2006 . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: • JUNE 4, 2007 . Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! Program Manager Rt 1f,/o DMMA 1300 Sumner Avenue, Cleveland, OH 44115-2851 Fax: (216) 241-0105 Phone: (216) 241-7333 Door& Access Syszems E-Mail: dasmadasma.com Manufacturers Association International URL: www.dasma.com DASMA ROLLING STEEL FIRE DOOR DROP TEST FORM General NFPA 80 and Model Codes require the inspection and testing of fire doors to demonstrate proper operation, full closure, and proper reset. Perform the visual inspection before the operational check, or before the drop tests of the fire door, in order to reduce the risk of failure during the drop tests. Use the form below to record the Visual, Operational, and Drop Test results. Check Pass or Fail in the boxes. See the Guidelines for additional information. I AWARNING I I Door could close rapidly and could result in death or serious injury. Perform drop test and reset per manufacturer's instructions. The drop tests, reset, repairs and/or maintenance should be performed by a trained door system technician with complete knowledge of this type of fire door and the manufacturer's instructions. Repair parts must be obtained from the original door manufacturer. After repairs are completed, the door must be tested to assure proper door operation and automatic closing capability. The fire door must be in the fully open position before the drop test. Reset the door following the drop test and test again. ProjectM Company/Ot Phone: Address: V.flc E-mail: to C Door Opening Size Door Mfr. Door Mfr. Location Serial No. Inspection Check Test #1 Test #2 Visual Operational Drop Drop I Width Height ___________ ___________ Pass Fail Pass Fail Pass Fail Pass Fail - - ez 06' 12- C.O*Ofl AAfi2&0q& ><: cooSor 7,pc1(, --T* Gfl OA G' 7il. >< Tested By: Witnessed By: t )ukin LAOc.ty&.re... Company: :isc;L Representing: Address: 22iWL/ .Ecr*o 4 1 Title:Tedru(ôr Signature/Date: Signature/Dat9JAH1?Wt%4i........ Rev. 6/07 DASMA Rolling Steel Fire Door Annual Drop Test Form - RDD-27 10 White - Building Owner Yellow - Service Company