Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6860 AVENIDA ENCINAS; ; FA090048; Permit
City of.Carlsbad Fire Alarm Permit Permit No: FA090048 6860 AVENIDA Job Address:• Status: ISSUED ENCINAS Permit Typ: FALARM . Applied 10/7/2009 Parcel No: 2144501900 . Approved: 10/7/2009 Lot #: 0 Reference No.: . . Issued: .10/7/2009 PC #: Inspector: Project Title: KAISER FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Owner: • KAISER FOUNDATION HEALTH PLAN INC 393 E WALNUT ST PASADENA CA Fees ($) • Add'I Fees : Total ($) Balance ($) 125 0 125 . 0 • 5 - 11770 Bernardo Plaza Court, Ste. 116 S.nENGIIVEERII$JG Di ego, CA 92128, Phone (858) 673-5845 Fax(858)673-5849 Fire Protection 1 Code Consulting U, Risk Control U Security Consulting FIRE ALARM SYSTEM PRODUCT SUBMITTAL PROJECT: Carlsbad Medical Office ADA Upgrades 6860 Avenida Encinas Carlsbad, California 92008 ARCHITECT: HMC Architects 1010 Second Ave. Studio 810, West Tower San Diego, California 92101 Fire Alarm: SIMPLEXGRINNELL, LP 3568 Ruffin Road, South San Diego, California 92123-2597 FILE Copy M 50,105 AliE E& I PRODUCT SUBMITTAL INDEX QUANTITY MODEL NO. DESCRIPTION CSFML NO. 4109-9201 NAC Extender 7300-0026:214 4906-9101 Strobe 7125-0026:316 5SimpIex LifeAlarm® Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 IDNet" NAC Extender for Control from 4010 or MEA (NYC) Acceptance* 4100U IDNet Communications; or from Conventional NACs Ihuii* Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Four, Class B (Style Y) NACs are standard: Rated 2 A each for conventional reverse polarity 24 VDC notification appliances and providing multiple operation modes Can be selected to provide synchronization for Simplex® visible notification strobe flashes Capable of controlling TrueAlert® non-addressable notification appliances operating with SmartSyncTM two-wire control mode** Input control options: IDNet addressable communications from a Simplex model 4010 or 4100U Fire Alarm Control Panel** Or from one or two conventional 24 VDC NACs with multiple output control options IDNet communications control benefits: Provides status monitoring and individual NAC control using a single address per 4009 IDNet NAC Extender Supports IDNet "Device Level" earth fault location WALKTESTThI operation is available with either input choices Internal 8 A power supply/battery charger: Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet Provides status monitoring of battery, input power, and earth faults Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes Rated 6 A for "Regulated 24 DC" appliance power Optional 4009 IDNet NAC Extender modules: IDNet Communications Repeater provides Class B (Style 4) or Class A (Style 6) output IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class A Four additional Class B NACs, rated 1.5 A for Special Application appliances; 1 A for Regulated 24 DC appliance power Class A (Style Z), Two Circuit Adapter Module UL Listed to Standard 864 I(1liIxIV*1I.1lFiTl1 IDNet communication fiber optic transmitters: For applications requiring the data integrity available with fiber optic communications Available as Class B (Style 4) or Class A (Style 7) Mounts in standard six-gang electrical box External battery cabinet for 18 Ah batteries t Simplex WALKTEST service testing is protected under U.S. Patent No. 4,725,818. Up to 8 NACs 4009 IDNet NAC Extender Optional IDNet I Channel Reoet ,I %\ \ %% GM. % \ % 2-Wire IDNet ' Communications 2E \ Fiber Optic IDNet i Communications Qr . NAC Control _.l•I_.IIII'-' - IDNet Fiber Optic Transmitter 4010 (shown) or 4100U Fire Alarm Control Panel Fire Alarm Control Panel with Conventional NACs 4009 IDNet NAC Extender Connection Reference Drawing iiiiitiiiiiiieuiiii• ADA Compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, a Simplex 4009 IDNet NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location Flexibility. The 4009 IDNet NAC Extender can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power distribution. Multiple operation modes and multiple connection options further increase location flexibility. Additional Information. For additional operation detail and application information, refer to Installation Instructions 574-181 and field wiring diagram 842-068. ULC listed model is 4009.9202CA. This product has been approved by the California State Are Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Listing 7300.0026:214 for allowable values and!or conditions concerning material presented in this document. It is suect to re-examination, revision, and possible cancellation. Accepted for use— City of New Your Department ofButdings—MEA35.93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. SmaitSync homlstrobeopemtion Is protected under U.S. Patent No. 6,281,789. IDNet addressable communications are protected under U.S. Patent Nos. 4,796,025; 5,966,002; and 6,034,601. 4100U requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. S4009-0002-4 2/2006 1ITur.imuisi.rSj.iit.ff1Irni.iiiipiiTIi1 IDNet Addressable Communications Compatible. Up to five, 4009 IDNet NAC Extenders can be controlled on a single IDNet communications channel. Each output NAC can be individually controlled for general alarm or selective area notification requiring only one point address per Extender. Individual Extender NACs can also be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles via IDNet communications. Optional IDNet Repeaters. IDNet communications can be repeated with the optional IDNet Repeater Module or with the optional Fiber Optic Receiver Module. Up to 100 of the IDNet channel points can be repeated once (refer to pages 3 and 5 for details). Repeated IDNet communications also support the "device level" earth fault location utility of the host panel. Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs additional power, the 4009 IDNet NAC Extender can be controlled directly from the NAC. Either one or two NACs, from either the same, or from different host fire alarm control panels, can be connected to control the 4009 IDNet NAC Extender output NACs. Multiple control selections provide flexible operation. (Refer to page 4 for more detail.) Alarms from the host panel will activate the four, 4009 IDNet NAC Extender NACs (or optionally, eight NACs) to extend the alarm. The 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions, including earth faults. Extenders wired to conventional NACs will indicate a trouble by opening the path to the NAC's end-of-line resistor, but retaining the ability to respond to alarms. Individual troubles are also annunciated by LEDs located on the 4009 IDNet NAC Extender main circuit board. (Refer to page 7 for more diagnostic information.) Product Selection Standard Models Model I Description 4009-9201 I 40099202CA* 1120 VAC input 4009-9301 240 VAC input * ULC listed mode 4009 IDNet NAC Extender with 4, Class B (Style Y) NACs and 8 A power supply Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B (Style Y), 4009-9808 Dual Class A (Style Z) adapter (for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A (Style 6) or Class B (Style 4) Select either an IDNet Repeater or a Fiber Optic Receiver as required 4009-9810 Fiber Optic Receiver Class B (Style 4) ~Class 4009-9811 A (Style 7 fiber, Style 6 IDNet) 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit I Beige trim 1-7/16" wide (78 mm), use if required for semi-flush installations 2975-9802 Red trim Battery Selection (select battery size per system requirements) Model - Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC External Accessories (select per system requirements) Model Description 4090-9105 IDNet Fiber Optic Class B (Style 4) operation 4090-9107 Transmitter I Class A (Style 7) operation 4009-9801 External battery cabinet for up to 18 Ah batteries, beige Comments Two batteries are required, 24 VDC operation Requires external battery cabinet, two batteries are reauired. 24 VDC ooerati Comments Mounts in six-gang electrical box, refer to page 4 for mounting details 16-1/4" W x 13-1/2" H x 5-3/4' D (413 mm x 343 mm x 146 mm) 4081 Series I End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details S4009-0002-4 212006 4090-9105, Class B (Style 4) Output Fiber Optic Transmitter Iwg..fiber cablea flflfl ft (914 m) maximun I%.•....e P.IAf., 4010 or 41001.1 Fire Alarm Control Panel 24 VDC power for fiber optic transmitters 4090-9107, Class A (Style 7) Output Fiber Optic Transmitter 4009 IDNet NAC Extenders internal IDNet Fiber Receivers EQlLfiber cables, 3000 ft (914 m) maximum dist Typical IDNet Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) 'IDNet addressable communications channel, shown Class B (Style 4) 4100U (shown) or 4010 Fire Alarm Control Panel Output NACs, four standard, Conventional NAC operation (horns) --- eight with expansion option It or Select conventional SmartSync opera !on per NAC 11 SmartSync operation (horns and strobes) 11FINIIIIIIII., Conventional NAC optional internal IDNet Repeater 4009 IDNet NAC Extender with ~92 eration (strobes) Reoeated IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5)4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections IDNet addressable communications channel Class B (Style 4) or Class A (Style 6). Class B shown / Reoeated IPM Channel: up to 100 devices maximum on repeater output. 250 devices total on IDNet Channel NOTE: Up to five (5)4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be, repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 54009-0002-4 212006 40,11111 nfi~~ NAC Input Selections. The 4009 IDNet NAC Extender can be selected to: Track input NAC operation or to provide a locally generated code, selectable per NAC input If selected for local coding, NAC outputs can be either Temporal Coded or 60 Beatslmin March Time Coded, one code selection per extender (input NACs must be on continuous with Alarm) Additionally, NAC outputs can be selected to provide the Simplex strobe synchronization signal. This signal will synchronize the flashes of synchronized strobes but will be ignored by free-run strobes and audible devices. (Strobes are for operation by noncoded NACs.) NAC input to NAC output control can be selected for standard and optional NACs per the following table: Conventional NAC Output Operation Options Input .A B C NACI NACs1&2,5&6 NACs1-4 NACs 1-8 NAC2 NACs3&4,7&8 NACs5-8 None SmartSync NAC Output Operation Input NAC Control Function NAC 1 Strobe Control - All NAC outputs (1-8) NAC 2 Horn Control SmartS-ync Notification Appliance Control The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAC Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification (protected under U.S. Patent No. 6,281,789) 4009 IDNet NAC Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs IDNet control allows output NACs to be individually selected for conventional or SmartSync operation With NAC input control, all output NACs are selected for either conventional or SmartSync operation Class A (Style Z) SmartSync operation requires SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003 for details) Refer to data sheet 54009-0003 for TrueAlert addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances Hardwire Control NAC Connection One-Line Reference Diagram Up to eight (8) output NACs total; hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input (see Note 1) ________ •-1, ____________ 4009 IDNet NAC Extender Fire Alarm Control Panel j with Conventional NACs NAC 2 input (optional, see Note 1) Conventional NACs With hardwire control. NAC outputs are all Output conventional or all NACs SmartSync operation 8 MT--A. EN SmartSync operation 4905-9938 SmartSync Control Module is required for Class A output wiring of SmartSync NACs To additional 4009 IDNet NAC Extenders (up to four (4), ] 4009 IDNet NAC Extenders per NAC); see Note 2 Notes: For separate audible and visible output NAC control, or SmartSync NAC output operation, two (2) input NACs are required. NAC 1 is on-until-reset' and NAC 2 is "on-until-silenced. To synchronize strobe flash outputs for up to four (4)4009 IDNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 for Class B operation, 4905-9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation instructions 574-181 for additional information and application guidance S4009-0002-4 2/2006 4009 IDNet NAC Extender Specifications Input Ratings 120 VAC Input (4009-9201) 3A @102-132 VAC, 60 Hz 240 VAC Input (4009-9301) 1.5A @204-264 VAC. 50/60 Hz Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A, Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs 12 A each, Special Application or Regulated 24 DC appliance power Output Ratings Optional NACs 1.5 A each, Special Application appliances (requires 4009-9807) 1 A each, Regulated 24 DC appliance power Special Application Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, and combination Appliances horn/strobes and speaker/strobes (contact your Simplex product representative for compatible appliances) Regulated 24 DC Power for other appliances listed to UL Standard 1971 or UL Standard 464; use Appliances associated external synchronization modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @24 VDC nominal Optional Modules Ratings Input Power 70 mA @24 VDC, system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 It (762 m) IDNet Repeater Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed Module 250 per channel) (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft (762 m) Total distance including "1-taps" is 10,000 It (3048 m) Class A (Style 6) loop maximum distance is 2500 It (762 m), no "T" taps Fiber Optic Receiver Modules Input Current p 4009-9810, Class B (Style 4), 65 mA @ 24 VDC, system supplied 4009-9811, Class A (Style 7), 80 mA @24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32" to 120" F (0" to 49" C) Operating Humidity Range 10% to 90% RH from 32" F to 104" F (0" C to 40" C) I Wiring Connections" Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Fiber Optic Transmitter Specificatiois Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B (Style 4). 30 mA @24 VDC 4090-9107, Class A (Style 7), 35 mA @24 VDC Fiber Optic Connections and cable requirements Multimode, graded index, 50/1251im, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors 4090-9105, Class B (Style 4) operation, two fiber cables required 4090-9107, Class A (Style 6) operation, four fiber cables required Module Size (with mounting bracket) 6-13/16" W x 3-3/4" H x 1-1/8" D (173 mm x 95 mm x 29 mm) On-board Status Indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class A (Style 7) receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 It (914 m) maximum Wiring Connections" Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity 10% to 90% RH from 32" to 104" F (0" to 40" C) Operating Temperature 32" F to 120° F (0° to 49" C) Metric wire equivalents: 18 AWG = 0.82 mm?; 12 AWG = 3.31 mm2 5 S4009-0002-4 2/2006 4609 IDNet NAC Extender Mounting and Module Placement Information I 16-1/4" (413 mm) Cabinet depth "I J"'4.1/4" (108 mm)J 10-29/32" (277 mm) Door, 5/8" (16 mm) thick — 0.1. Optional Class A 4009-9807 Additional Four 13-1/2" e \\ (adapter modules 1) ltpoint module (shown with I (343 mm) © Class A adapters) © Exposed cabinet I_I dimension for—I - [ System Module j 0Rfl semi-flush mount 00 1"(25.4 mm). Knockouts for screw II C4iber :e ' t repeater QE 1.3/8" (35 mm) with or nail mounting holes II pticreceive;) [Iii semi-flush trim ale —@ wl. I e a I Op I I :1 I I 12" (305 mm) Battery location, no conduit entry or wiring in this area (12.7 Ah battery outline shown) ELK :0 O• VJ Semi-flush trim option — T — - Non-power limited wiring area (AC input) 1-3/16" wide (30 mm), 3/8" (9.5 mm) thick L Wall surface reference for semi-flush mount d NOTE: Recommended conduit entrance vanes with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009IDNetNACExtenderCabinetwithDoorDetail Optional red appliqué (4009-9805) 84009-0002-4 2/2006 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information - Surface mount box: Simplex model 2975-9217 (ordered separately) Flush mount masonry box: use 6-gang box, RACO # 960, 2-112" deep (64 mm), or RACO #965, 3-1/2" (89 mm) deep, or equal (supplied by others) MOM Flush mount ganged boxes: use 6-gang box, 1-1/2" (38 mm) minimum depth; six, RACO #400 or equal, (supplied by others) IH I I •I I . IiIIm • U No _ . -- U. .• IL!'TIF -- Ir IyiI o o 0 0 0 0 o o 0 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class A (Style 7) output 4090-9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) Power-up Self-Diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The 4009 IDNet NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit - During an alarm, the LED follows the NAC output (on steady or flashing with coded output) Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-4 212006 4009 IDNet NAC Extender Current Chart 0 - Panel Module Selection (shaded model numbers are optional modules) Model Description Supervisory Current Actual Supervisory Alarm Current Actual Alarm 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA + + NAC loads + NAC loads (add below) 4009-9808 Dual Class A Adapter (current - - - - included in basic panel value) 4009.9809* IDNet Repeater 70 mA + 70 mA + - 4009-9810 Fiber Optic Receiver, Class B 65 mA 65 mA 4009-9811' j Fiber Optic Receiver, Class A 80 mA 80 mA IDNet Devices, 0.7 mA each, maximum of 100 Total devices + Total devices Al + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output, calculate per total 500 mA + 500 mA 'A + device requirements (see note 5) maximum maximum ' ' Total Supervisory Current = (A) + Total 4009 IDNet NAC Extender Panel Alarm Current = (BI) * Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads - NAC Type NAC Circuit # NAC Alarm Current Circuit I + Circuit 2 + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum per NAC (see note 5) Circuit 6 + Circuit 7 + Circuit 8 + Total NAC Loads Alarm Current = (B2) + Total 4009 IDNet NAC Extender Panel Alarm Current (enter BI from above) = Procedure: Total Alarm Current = uaicuiate total panel supervisory current (A). Calculate total panel alarm current (12111) [convert mA to A, example: 350 mA = 0.35 A]. Copy (B1) into block (1212). Calculate total NAC loads alarm current from notification appliance ratings (C). Add (C) + (B2) to determine total alarm current (D). Total of IDNet Device Current (Al) + Auxiliary Power Output Current (A2) + NAC Loads Alarm Current (C) is 8 A maximum. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements (i.e. 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco. Simplex, the Simplex logo. LtfeAlann, IDNet, WALKTEST, SmariSync. and TrueAlert are trademarks of Tyco International AGar its affiliates in the U.S. and/or other countries. 93 .Simplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4009-0002-4 2/2006 www.tycosafetyproducts-usa-wm.com 02W6 Tyco Safety Pw!ucLt Wesiinisame,. All rghu reseried. Allspec6caliont and other infonnation shown nurecwrentas ofdocument revition dale and are subject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL SERVI USTENG CE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7300-0026:214 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 874-8542 FAX (978) 731-8881 DESIGN: Models* 4009-9001, 4009-9002, 4009-9101, 4009-9102, 4009-9201, 4009-9301, 4009- 9401 Notification Appliance Circuit (NAC) Power Extenders. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 4090-9105, *..9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803,-9804 4 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module *40039803 Remote Microphone Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. Rev/Recert. 03-29-2006 jw . . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 8, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division GSimplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTm Operation Compatible Itui* Visible only VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: UL listed to Standard 1971 Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: 4006, 4008, 40 10, and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 lDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 71254=316 for allowable values andlor conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Tim Recorder Co. are the property of Tyco Safety Products Westminster. Wall Mount Strobes Ceiling Mount Strobes 7)p_s crintir Multi-Candela lrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. IIIS1IIIIL(1II ILl' 11[OLSIILSII During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Simplex multi-candela SmariSync two-wire homlstrobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559,492 5.622,427; 5.865.527; 5.886.620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906-0001-2 512007 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Class B SmartSync two-wire control is available from: 4006, 4008, 41001.11, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Class A SmartSync two-wire control is available from 4100U NACs and from the 4905-9938 SCM. Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. [Product Section Multi-Candela Visible Notification Appliances (Strobes) ____ Mounting I Housing Cob! "FIRE" Lettering I Description 4=9.1.01!!I Red I White I Wall I Multi-candela strobe with intensity selectable as: 115, 30, 75, or 110 candela; synchronized flash rate; i White I Red I 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 I I White I Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" 0 4905-9940 White deep surface mounted boxes (136 mm 133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter I Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description - Dimensions I 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8" x 2-7/16" x 13/16" in/out 18 AWG (0.82 min 2) wire leads, rated for 2 A NAC, 4905-9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering I 5-1/8" H x 5" W x 1-1/2" D For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering I (130 mm x 127 mm x 38 mm) 49059961* Wall mount I 6-1/16" H x 6-1/16"W x 3-1/8" D Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9926 Ceiling mount 6-1/8" x 4-3/8" x 2-7/8" deep (156 mm x 111 mm x 73 mm) UL listed by Space Age Electronics Inc. 2 S4906-0001-2 5/2007 Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note I below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8' W x 2-3/4' D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd jr 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 55 mA 85 mA 169 mA 226 mA 41 mA 63 mA 123 mA 164 mA Housing Dimensions (with lens) 4-3/4" Lx -5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 64 mA 102 mA 199 mA 266 mA 49 mA 76 mA 146 mA 195 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with single gang, double gang, and 4' (102 mm) square boxes, 1-1/2' (38 mm) deep, by others Wiring access hole IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r -Electrical above bottom H r box outline of compatible boxes i NFPA 72 requires 80' (2.03 m) that the entire lens minimum be not less than 80' and not greater than 96" above the finished floor Removable cover Strobe intensity (tool required) viewing slot S4906-0001-2 5/2007 Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V5744S) 2-1/4" (57 mm) deep, supplied by others Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with Clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for surface mount with handy box unless - cal j using the 4905-9926 wire guard I-I I-I Ceilina mount strobe Optional 4905-9926 wire guard with mounting plate - - Strobe intensity I viewing slot Intensity selection plug, - accessible only from rear of lens: housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt lL ' 4905-9931 Adapter Plate 4905-996 1 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco. Simplex, the Simplex logo. iDNet. TrueAlert. and SmoriSync are trademarks of Tyco international AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). O Tyco Safety Products Westminster• Westminster. MA • 01441-0001 • USA S4906-0001-2 5/2007 .Slimplex www.tycosafetyproducts-usa-wm.com 02007 7)ico Safety Products Westminster. All rights reser.,ecj All specj/icazions and other information shown were cununt as ofdocumen:rev,sion date and aye subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTENG SERVICE &I LISTING No. 7125-0026:316 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441-0001 Contact: Paul Mattern (978) 7318542 Fax (978) 731-8881 DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and —9103 are for wall mount. Models 4906-9102 and —9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or .'. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division