Loading...
HomeMy WebLinkAbout6030 AVENIDA ENCINAS; 101; FS110010; PermitCity of Carlsbad 04-06-2011 Fire Department Permit Permit No: FSIIOOIO Job Address: 6030 AVENIDA ENCINAS CBAD St: 101 Permit Type: FIXSYS Subtype: SPRAY Parcel No: 2110302700 Lot#: 0 Fire Dept Ref#: FS110010 Building Permit#: CB110705 Location: Project Title: CARLSBAD COLLISION Description: SPRAY BOOTH Status: ISSUED Applied: 04/06/2011 Issued: 04/06/2011 Entered By: BSW Contractor: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 92069 Phone: 760-310-6122 Fax: Total Fees: $210.00 Total Payments To Date: $0.00 Plan Check Fee Additional Plan Check Fee Permit Fee Additional Permit Fee Re-Inspection Fee Other Additional Fees TOTAL PERMIT FEES IC $80.00 $0.00 $130.00 $0.00 $0.00 $0.00 $0.00 $210.00 NOTICE: Please take NOTICE that approval of your project includes the °lmposidon" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this.permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. tLIO/ Fire & Building Products Technical Services: Tel; (500) 3814312 /Faor (500) 791-5500 Series ELO-231B - 112 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage G sentative of at possible corrosive at. enera mospheres. Consequently, It is Description mended that the and user beconsulted respect to the suitability of these corrosion resistant coatinos for cliv The 11.2 K-factor. Series ELO-2310. Standard Response, Standard Cover-age. Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin-klers of the frangible bulb type. They are 'Standard response - spray sprin- klers' that produce a hemispherical waterdlsirlbution pattern belowthede- fectar. - The 11.2 *factor, ELO-230 Sprin- klers were Sub ad to full scale, high- =0, Ore team to qualify their use In lieu of 5.8 or 8.0 K-factor stand-ard opisy sprinklers for the protection of Ngh-piled storage. Higher flow roles can be achieved at mach lower pressures with th e 11.2 K-factor, ELO-231B Sprinklers - making their use highly advantageous In high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the lila of the copperalloy com- ponents used In Series• ELO-2319 sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lOad, and polyester Coated sprin-hints have passed the standard corro- sIon tests of the applicable approval agencies, the testing Is not repro- Page 1 010 JANUARY, 2005 TFP342 given corrosive envtronmeiit. The ef- fects of ambIent tempersiure, concen- Irstion of chemicals, and gas/chemical velocity, should be Considered, 55 5 minimum, along with the corrosive OS-lure of the chemical to which the Sprin- klers will be exposed. An upright Intermediate level version of the Series ELO-231B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-2319 Up- right Sprinkler with the WSG-2 Guard .S... and a pendant intermediate level version of the Series ELO-2310 Sprinklers can be obtained by utiliz-ing the Series ELO-2315 Pendant Sprinkler with the WS-2 Shield. If there Is possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 112 K-factor, Series ELO-2318 Upright and Pendant Sprinklers do. scribed herein must be installed and maintained In compliance with this document as well as with the Ar e b/a standards c/the National FIre Pro. motion AssocIation, In addition to the standards of anyolherauthouftles hay. Ing/wlsdlcllon. Failure to do so may hnpalr the performance of these de- sloe,. - - The owner Is responsible for maintain-big their fire prober/on system and de- vices in proper operating condition. The InstnIiin.g conlmcfor or manufac-turer should be Contacted with any qaasden&, Insraiiaiion of Sodas EL04318 Pen-dant Sprinklers in recessed escutch-eons will an/dall sprinkler warranties, as wail as podaibly void the apulnbler's Approvals and/or Listings. Model/Sprinkler Identification Numbers TYSI5I - Upright 11.21K, 3/4NPT TY5251 - Pendent 112K,3!4NPT TY5851 -Upright 11.2K, 11NPT TY615I Is rodesignstlon for C5151. 1Y5251 Is redsslgnalion for C5251, 01871. and $2531. TY5851 Is redeslgnatlon for C5851. Technical Data Approvals Ui. end C-UL Listed. FM and NYC Ap-proved. (Refer to Table A for con1piste approval information Including corro-sion resistant status. The approvals apply to the service conditions Indi-caled in the Design Criteria section.) Maximum Working Pressure llfl psi (12,I bar) Discharge Coefficient K 112 GPM1pslt12 (161,4 LPMlbsr'°) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame -------------Bronze Cap--------------Bronze SeailngAsaembiy ............ - - . . - Beryllium Nickel w/Tettont Bulb (5mm die.) -------Glass CompressIon Screw .....Bronze Deflector ............Bronze t Registered trademark of DuPont Page 2 of B TPP342 ) SPRINKLER FINISH TYPE TEMPERATURE BULB LIQUID NATURAL CRASS CHROME PLATED LEAD COATED WAX COATED WAX OVER LEAD 155'F108'C Red 1.3,3,4 3 (T1I51 sgrpenc Green 518F/141'C eisa 3 I PENDENT - taa'FAB'C Rod 1,2,14 ._!_. 3 2oeyn3C Green 25e'Fi14i'C NOTES: t. Listed by Underwriters Laboratories. Inc. (UL Listed). Listed by Underwriters Laboratories. no. far use In Cando (C-UL Listed). Approved by Rostovy Mutual Research Corporation (FM Approved). Approved by the City at New Thib under MEA29t44-E. (a). FM Applosnd for maximum calling temperature of 15F/GntC TA OLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES EL 0-23 iS UPRIGHT AND PENDENT SPRINKLERS (Rater to the Design Criteria Section) Design Criteria UL and C-UL Listing Requirements The 112 K-factor, Model ELO-2318 (TY5151, rY5251 & TY5851) Sprin-klers are to be Installed In accordance with NFPA 13 standard sprinkler posi- tion and areaidensliy (tow calculation requirements for light, ordinary, ares-ira hazard occupancies with a mini-mum residual (flowing) pressure of 7 pal (0.5 bar) In wet ordry pipe sprinkler systems, or they are to be Installed in accordance with NFPA 13 standard sprinkler position and area/density now calculation requirements for high plied storage occupancies (solid plied, palinlized, rock storage, kin bos, and shell storage including but not limited to Class t-iVund Group A plastics) with a minimum residual (flowing) pressure of 10 pal (0,7 bar) for wet or dry pipe systems. The following example in typical of the type of arrangement permitted by NFPA 13. For all combinations of iasser and greater building heights, lesser and greater storage heights, storage arrangements, commodity ciasslllcatlons, and lesser or greater required design densities, refer to NFPA 13 for specifies. Example: NFPA 13 provides cal/big only protection (La.. no In-reck sprin-klers) criteria using open frame (i.e. no solid sheWas) aingle, double, mull/pie-- mint or portable reck storage (without TFP342 Page 3 of 6 Peg. 4 of 6 TFP342 TmnEerskze mlhig Is kidlcotod or deflector. Flye thread oorweelora Per ISO 711 can be provided or us- (12.7 505) Pal request.JIIN*LMAKE.111 We Ir ij Coniponaft — I - Frame 2-Seal 2- I ThREAD Sunambly (71 WRENCH - FLATS If1J_)IELIEF 4 4-60 3- Cap 5- Cmnpmsnk 5 Soew 14. NFr NPT ler(I2.7IWl) NOM1NALMAIt5411 NOMINALMiKE411 UPRIGHT UPRIGHT PENDENT CROSS TY5851 TY5I51 TY5251 SECTION FIGURE I 11.2 K-FACTOR SERIES EL 0-2318 UPRIGHT- ow NPT(1Y515l), UPRIGHT- l.2 NPT (TYSOSI), AND PENDENT-3f4 NPT(TV525I) SPRINKLERS Me need for In-rack sprinkler proton- Operation E: of ca,loned or uricartonfice ed unex- pa p A orB pl. • r The glass beds contains B fluid that toned expandedGreupAorBpiastica.expands when exposed to heal. When a storage height ohip to 20 foot (Al m); a maximum ceiling height 012? feel (2m); a minimum deflector to top of stor- age clearance of 18 Inches (457 mm)" a minimum design density of 0.60 gprn4i2 (24,4 mm/mln); a minimum residual (flowing) pros- sum of 10 psI (0,7 bar); a n'Jnlnusn design area 012000 112 (186m°) for wet systems or26001112 (242 m2) (or dry pipe systems FM Approval Requirements The 112 K-factor, Model ELO-2310 (7Y5151, 1Y5251 & TY5851) Spin- Mets sty to be Installed In accordance with the applicable'control mode den. SKY guIdelines provIded by Fac- tory Mutual. (FM guIdelInes may differ from UL and C-UL Usting criteria) fluId expands suffidently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Installation The Series ELO-2318 Sprinklers must be Installed In accordance with the fol- lowing Instructions: NOTES Do not Insiafi any bulb type sprinkler if Me bulb Is cracked orthere Is loss of liquid from the bulb. With the sprinkler held bartzontolly a small air bubble should be present. The dlamaierof the air babble Is approximately 1/16 Inch (1.6 mm) for the i55FIWC to 3132 inch (2.4 mm) for Ihe 286FfldPC temperature ratings. 14 11.1218. 0121 ft. be used iPT con- quo may Do not attempt to make-up for Insuffi- TOWARDS SPRINKLER FrrrING WRENCH R FIE ECESS (2NDW) RGURE2 W-TYPE3 SPRINKLER WRENCH dent adjustment In the escutcheon plate by under- or over-tIghtenIng the sprinkler. Readjust the position of the sprInkler filling 10 suit. The Series ELO-2310 Upright and Pendent Sprinklers must be Installed In accordance with the following In- utrucllonu. Step t Pendant sprinklers are to be Installed In the pendant position, and upright sprinklers are to be Installed In the upright position. Step 2. With pipe thread sealant ap- plied to the pipe thmads hand tighten the sprinkler Into the sprinkler tItling. Step 3. Tighten the aprinlder Into the sprinkler filling using only the W-Type 3 Sprinkler Wrench (Rat. Figure 2), except that an B or 10 Inch adjustable Crescent wrench is to be used for wax coated aprtnklere. With reference to FIgure 1, the W.Trpe 3 Sprinkler Wrench or the adjustable Crescent wreneft as applicable Is to be applied to the wrench Ilata. When Installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms end. consequently, exposure 01 bate metal to the Conceive envIron-menL The jaws 01 the wrench should be opened sufficiently wide to pass over the wrench lIsts without damag- rIn ing the wax coaling. Before wrench lightening the spkler, the jaws of the wrench are to be adjusted to just con-tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. - - Alter Installation. the sprinkler wrench flats and frame arms meet be In-spected and the wax coating re-touched (repaired) whenever the coat. lag has been damaged and bare metal Is exposed. The wax coaling on the wrench tlats can be ratoached by gen-tly applying a healed 118 Inch diameter 51001 rod to the areas 01 wax that have been damaged, to smooth it bade over areas where bare metal Is exposed. NOTES. Only retouching of the wax coaling op. plied to the wrench tiers and frame arms Is permitted, and the retouching Is to be performed only at the time of the initial sprinkler Installation. The steel rod should be heated only to the pointer which It can begin to melt the war, and approprIate precautions need lobe taken, when handling the healed rod, In order to prevent the Installer horn being burned. If attempts to retouch the was coethrg with complete coverage are unsuc-cessful, askSllonat wax can be Ofllelsd In the form ofa wax stick (the and 01 which 150010, coded). Only the correct color coded wax Is to be used, and retouching of wrench fate and frame arms Is only pennilled at the time of Initial sprinkler lnslallatlen. With the steel rod heated as previously do- acribed touch the rod to the area in- quIrIng additioM':: al war with the rod an-gled downward, and then touch the wax stick to the sod approximately one-half Inch away from the area re- quIring retouching. The wax will melt and run down onto the spitnkier. Care and Maintenance Series ELO-231B Sprinklers must be maintained and serviced In accord- ance with the following Instructions: NOTES Bofors closing e tire protection system control valve for. workon the fire protacllon system that It con- trols. permission to shut down the af- fected fire protection system must be obtained from the proper authorities end all personnel who maybe affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs 01 corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi-fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion. but have not operated should be replaced It they cannot be , completely cleaned by wiping the sprinkler with a cloth or by brushing It with a SoIl bristle blush. Care most be exercised to avoid dam-age to the sprinklers —before, during, and after InstallatIon. SprInklers dam-aged by droppIng, strikIng, wrench twlal/sllppege. or the like, must be to- placed. Hun, replace any sprinklerthat has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual Inspections are rec- ommended to be Initially performed for corrosion resistant sprinklers, after the Installation, has been completed, to verify the long term potential Integrity of the sprinkler coatings. Thereafter. annual Inspections per NFPA 25 Should suffice; however, Instead of In-specting from the floor level, a random sampling 01 close-up visual Inspec-tions should be made, so as to better determine the exact sprinkler condi- lion end the long term Integrity of the colroslon resistant coaling. as It may be affected by the corrosive conditions present. The owner Is responsible for the In- spection, testing, and maintenance of their fire protection system and de- vices In compliance with this docu-ment. as well as with the applicable standards 01 the National Fire Protec-ton Association (ag. PIFPA 20), In addition to the standards of any other authorities having jurisdiction. The In- stallIng contractor or sprinkler manu-facturer should becontactedrelstiveto any questions. It is recommended that automatic sprinkler Systems be Inspected, tesled, and maintaIned by a qualified Inspection Service in accordance with local requirements and/pr national code. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work-msnshIp when paid for and property Installed and maintained under normal use and service. This warranty will ex-pire tan (10) years from date of ship-ment by 1rco Fire Products. No war-ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject 10 misuse. Improper Instailatlon, corro- alan, or which have not been Installed, malnlalned, modllled or repaIred In ac- cordance with applicable Standards of the National Fire Protection Aaaocts-lion, and/ar the standards of any other Authorities Having Jurisdiction. Mate-rials found bylycoPre Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole optIon. Tyco Fire Products neither as-eumes, nor authorizes any person to assume for It, any other obligation in connection with the We of products or parts 01 products. Tyco Fire Products shall not be responsible for sprinkler system design errors or Inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE. IN CON- - DAMAGES, AND-IN NO EVENT SHALL TYCO FIRE PRODUCTS' U-ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. - MW FOREGOING WARRANTY 1.0 EM LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS DR - ROPLIED, EMOLUGING WARRANTTEE OF MERCHANTABILITY AND FIT, NESE FOR A PAR7ICULAR PUR. EQE- P/N 50- XXX - X - XXX TEMPERATURE RATING isa 155F1WC 200 500F1WEC 208 2ee'FIt4lC TABLES PROOUCTSVMBOL NUMBER SELECTION 213 K-FACTOR SERIES ELO-2315 STANDARD RESPONSE UPRIGHTAND PENDENTSPRINKLERS TFP342 Page 5 o S Page 6.16 TFPSS2 Ordering Procedure A Part Number (PIN) is not specifiedwhen ordering sprinkleN with thread connections per Iso 711. Contact your local distributor for avail-ability Sprinkler Assemblies with NPT Thread Connection: SpecrtF (specify SIN), 112 K-factor, (apacily temperature rating), Series Et,O-231 B Standard Response (spec-ily Pendant or Upright) Sprinkler wllh (specify finish). PIN (specify from Ta- Sprinider Wrench: Specify: W-Type 3 Sprinkler Wrench. PIN 58-895-1-001. Wax Sticki: (tar retouching wrench damaged wax coating) Speclfpr (Specify color) color coded Was Slick for retouching (specify tem-perature ruling) temperature rated Se-ries ELO-1B Sprinklers, PIN (opec- ify). Rod Is, 155'S ............. RN58ec5-i-155 abe Is ise'Saad au-F ................. PIN sears-i-ma NOTES Each wax stick is suitable for retouch- leg op to twenty-fire sprinklers. The wax used for SErF sprinklers is Me same as for 200F sprinklers, and therefore, 111e286-Fspnnklerlsiimited to the same maximum ceiling tempera. ture as the 200F sprinkler (i.e., 150W). TYCO FIR! PRODUCTS, 451 North Cannon Axenea, Lass5atA Peistotivanla I9448 Dyna-Flow® High Strength Steel Pipe The original high-strength lightwail sprinkler pipe with hydraulics superior to Schedule-lO. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger LD.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables" Specifications NPS Nominal I.D. VA. WI. (1,120 Filled) Pea/ WI/LIft (21') WI/Lift (24') WI/Lift (25' In; mm In; mm LbsiFt; Kg/rn Lbs/Ft; Kg/rn Lift LOs; Kg Lbs; Kg Lbs; Kg 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1%, 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 1W 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2½' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologitally Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for thy systems uses. TAdditional IBenefits a Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tqco/Flow Control () allied 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUrr 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 DynawThread 0 Full Line Sch-40 Replacement Dyne-Thread' offers the life expectancy of Sch4O with superior hydraulics and gmater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinider pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (D <~> @ Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "AM". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Comparison to L.W.T. Ig More wall thickness at the thread (CRR1 .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pc WVLiIt (21') WIILift (24') WtlLift (25' In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/n? Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11/4* 1.408 1.870 2.54 51 2002 2288 238 32 35.8 2.8 3.78 51 908 1038 108 1%' 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 allied 16100 S. Lathrop Harvey, IL 60426 Customer Service: tlICO/Flow Control aiie.1 11350 No=m Rd. . Philadelphia, PA 19154 (800) 882.5543 TUBE & CONDUrr 2525 N. 27th Ave. • Phoenix. AZ 85009 Fax 708-339-1806 S3-3 ..r 'M d 7.5 S. Ir i P.802042 1FP1650 Figur iseds e 772 Grooved Coupling Mielmiun ivailMie gap between pipe ends. Minkleun gap • 0. I Meoticlue, plunlel Iced mid teed 0cl 10181 healed based on ilaildeld notate limit p61.. Prssaur, 1.15191 arid and be* may dilleren oilier pipe materIal. 1.11dm, Well deler.e. CeiltaotTyeo Pm Predueta lee 001810. S.. FIr. platelitan Eqdyniii0 Oginnial nICest for Ltoirig and Appinval P110001 r.1619.. mMrto boll .603 IreSviiabln Leon request * Men Eel Gap Ii for eat elooned standard w.ldmrl pIpe. Vahea for inS grooved pce 101365 tevelofa,tgwwig FIgme 772 RlgldCeu,doe. lane 1A881-petellon FeaSt. 1194 big Inolif along Ole eelqcelg kage hi idnee 1W .4. wPm 01065 the Fleor. 772 peiledlp sited toe wm0 over kelalatlene wino, the Ikolaleed of rotation togroolast Ill, leaSt, may 08116115. era noel 01 lIar. laligeratean419ell elI Ifl0 aver1.ebkuna500 datedyand glleittg tarn. ilidlig line lad noes. General 100181:11410.011151104'. Ieepoee1bity Ia aIled p10d120 1011161. lerla. Intended Ilinlai arid toenaIl. S that pleme.1016152nd pedennanno data Is .ini eaueed.d. AIrily, read and ondwstutid the krMiaattan hrstnudlens(114-IWI). N.o,rrnlnm, My piping nonrpmr.l oreolred or nedllr.ny plehig didlded..wslieia CIII dlpreoealzkig end drulidlig the epaulet MuddleS and geilrat 0.4.015.1 would be vect000 to be 000lpatlkle Ior5r5.pigloappenslloit Ceitifled Company TYCO FIRE PR000JCTm. 451 NiothCiinionAvmnar. Lairodal.. Pel01ytvunha 18908 Pined use. PIpe Ma'e.* End Gap Man.t Pressure Maat End Load Nominal Dimensions __ Net - O.D. A B C Size Incises Indies psI Lbs. trachea Indies In es Lbs. mm iron bPs N iran mm mm - - Kg. 1.660 0.06 300 649 2.75 4.38 1.81 Wn2W 1.0 42.4 1.5 2.068 2.887 69.9 111.3 46.0 M10 x57 0.5 1.900 0.08 500 1,417 3.00 4.62 1.81 Wx2W 1.0 48.3 2.0 3.447 6.303 76.2 117.3 46.0 Ml0x57 0.5 2' 2.375 0.13 500 2,214 3.41 0.12 1.88 %x2W 1.5 60.3 3.3 3,447 9.848 86.6 130.0 47.8 Ml0x57 0.7 2W 2.875 0.13 500 3,244 3.91 5.63 1.88 %a2W 2.5 73.0 3.3 3,447 14.430 99.3 143.0 47.8 M10 M57 1.1 3.000 1.13 200 2,120 4.19 5.72 2.00 6110557 2.6 76.1 33 2.068 9.430 101.4 145.3 50.8 1.2 2' 3.500 0.13 500 4.808 463 625 1.88 Wx2W 2.6 88.9 35 3.447 21.387 117.8 158.8 47.8 M10x57 1.2 4.500 0.19 500 7.948 1.81 7.50 1.97 •Wx2W 35 114.3 4.8 3,447 35,353 147.4" 1904' 50.0 Ml0x57 1.6 139.7... 5.500 0.19 300 7.127 7.02 9.72 2.08 M18a68 139.7 4.8 2,068 31.701 var 7464' 52.3 3.4 -;:- 5.583 0.19 300 7.288 7.09 9.71 2.04 W 3V. 7.5 141.3 4.8 2.068 32.417 180.1 246.6 51.8 M16x83 3.4 1651 6.500 0.19 300 8.950 8.09 10.53 2.13 6116 83 7.6 161.1 4.8 2.068 44.258 205.5 767.5 54.1 34 6 8.625 0.19 400 53.763 8.09 10.53 2.13 Ws3W 7.6 161.3 4.8 2,758 61.302 205.7 767.7 54.1 M16x88 3.4 8.625 0.19 450 26278 10.56 13.56 2.62 Wn4W 18.0 219.1 4.8 3.103 116,885 268.2 344.4 885 M20x12l 1.2 10.750 0.13 250 22,679 12.84 18.41 2.62 t'a8W 24.6 273.0 3.3 1,724 100.876 328.1 416.8 66.5 M24x 1611 11.2 12.750 0.13 250 31,903 15A1 18.84 2.82 ?x6W 42.0 323.9 3.3 1,724 141.905 391.4147&51 68.5 M24x 165 19.1 tLICOFire & Building Tot: (800)381-93121 Fax (800) 791-5500 www.tyoo-Iire.00m xrei Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General lIneal Gentle Irixi noidcnrki to sticijld be anetactod ietotive to any questions. yTM A-536. Grade 6545-12 deytiiqidman meet beleveeetatelyanaictod. Description pinlsntviceollega It to recommended that autoelatto spitokler -leidotinçO pairs estraimbebmpnoledtoeted. and iirabotimdby Re 616810 led (optlram non-lead petal a qualified Iropentlen Deleted. Holdippidatvmi01idnoeteindngtoASTM Limited ( UotUN TIaCIC - 000iomting to Warranty ASTM A-193, Zinc Plated. (Min. TensIte. 1*800 psV758.422 cPa) ROAM eemj00aid by Tyco Rho Ridgi an Metg10-metom*igtoifSlM F568M nthiw1bdeDidthonlWlai(15)mes Onal 511001 lee (spidtywtian soft)soft)iddItjigi18aklvteTinedtWmipou 6010191101 • Glide W EPDMAelotel colercode 60apepe1y6idaidnde38idcagime1id RoWn Lithlgldpl0001t IntimationIntimationwrb101itto+150•F(l€6•C)tollhplctnetbl em01noe1Ttoid1(tO)mee SystemS. Not recommended for tint wider tiren 20 at lxval lip Toe lbs Rrati No 1ejnmdGeidegpIeo20ac1$idby systmim wanady to em tar plel an nolipranote TtI-aeal(CindoTEP0M).gcnnncolornode nuedbymoopde8001raMonddy gmonoJ15Idmedenes tosbind tardy F*5 to, use 61 dqr pIpe orfmewoyotein 80 owlaeR11 rop10te ard*dee.Rpunfl2Ge4th152 • Plokthdinted (Gindo A EPOMA) vd11tt1.bo1otoote*I,ee.n-.I.lJu amIty IdeididatI061019*iolvt (See Veto S0.eIIFPI6SD for old In selecting oeicoOtmy20lImeidl80Notiiinfl ishvitelpithis ppergiakel) n an id in anodeno aOl appikable (3d47Mi)do10getoboaednidttitenom of Gftft)Wft edmeemllatoepisledbionvbo. Ordering ft" J# I20No bout lip Tw the RIpMC][tlI91WIl1.10I0020l15pIp111id Procedure . to be 11e did be 011w InpeEnd an 6enemqifledlaa. ie11TwlaePl0141igcçdot Tyfte 111l WhenplaMill]an order, bidledtnthe ui limitedlimited Tim risen 272 Rbjd 4Jto19 heidi nannMenepecltythequaatity.tIpumnomber. to1.5S60L5IYXW11101WI60WOl ,,nadbens10headniddeonuhrmmeulh 1yp0id915t1*GmdeA EPCM lahabotcated Seeded pidanpatedphe Tyco lbs 20deonon4enudeOlhalandeih (GradeA'EPOMA)erGradnE"EPOMTII-Seal, lade dirnte* 04' p11 di1wa010'*de las*51 GIbtdG50idFE19Rndid it1w o ranBsp1iWI38}.na ,k88kan hetin to do no day kiyek Se ad otter predigi 9! anda1w Sm,jplesd Um IN NO MW WALL 7VW WE PIMM BE porwrippordow U3.Gene166derm 6owdl .adancacndanik We emwlaioped 1wnid58*ipthelen ddbstldheiorla2.YwnlaynoDedeoettiiannd uonvoiouvrue. yshe5)20nanI *cys81iip 21576267 antle86ctsitarmnoleatysL emdibs lie 1120*ip en'lt1 an aptlator Care and FEAFAMORWIffIrCIFIREPROMM WPS188JT1)EUIYEPSDt Technical Maintenance W#SK AND IN ND SW SiALL TYM FIE The owner to inspolettile Is, to Inspection, 1.lSUlaITYSN4MWIrB11PL Data testwç,eiutnialnlensnceetthdrttie pretcollee 10199522250188. Ageos: m s5tOfli arid deetina to accordance 1110 the fl( U7io81166tdV Sloan 1W- ableslaidsdeeftheNatiomatRrePridedlen -Aj I99elIBM Appansilec III., Rd. ULC. VdS, acid LPCB; dssactetlsn (ag. NIPA 25), In uditltlee to tIe AMELIED. -1111011111111111 WAMIIflFZ See Rio detentIon SetoidttolSlentfareuast Italgilito of any aithedly levblg )jtlndlclloe. M385210 8 RI23 I liioltilglif4lprovat tiltenralbi 11arkbaIignoeb'actpinductmaaotnntacer ZA20L 6. Page 1 o12 July 2004 TFPIOSO lPoroducts Technical Services. Fire & Building tqco/Products Technical Services: Tel: (800)381-93121 Fax: (800)791.5500 Www.lyco-llro.Cam Grinnell Grooved Fire Protection Products Grooved Fittings General Description Submitted Shed for Premium Ruling and LlullnglAppmval lnbmeixn lgvedtilllrigapravldeaneonnomlcai andeflldestmthodolchanghigdhuction, adding on 00881, uathiclng, or capping grooved piping systems. Grooved fittings are uvaSable In durable ductile Iron or fabricated elect an Indicated. Unix: Figure 5108 and 5180 tlftloo are special start indian filling, with small,, center to and dlmaxnloxo than standard grooved Ilitingo. Depending on ths sloe and coupling nod, there mayba Interferences eI the bull pads Unit require repositioning otths coupling orientation. The ace 01 hinge adapters Is not recommended with Figures 5100 and 519$ llttlogn. Contact Tito Flea Products tar details. WARNING The Rlthgs descatbod heIn mast be fnstaltd findrinfidahnadinagnitalmal as sell as with the applharbln sthsnbnfs of its AWAM lnadhitton to the standards at aw/offer jatliadtfes Will ludsdicfjaru FilIal, On do so may Impair to, pertgonna,, at tills North,. The owner Is iasparolblo fo,malntandsp fiat, fin pmtsctlon system and devises In proper epemtlngcondlliaa molnstsifingcaebsstorar npdAMermar,ithci.a,nrslrouldixcaiwsrftdve'th air, questions Technical Data 8pprcvain: UL Fl& ULC. VdS. aid 1)00; belio Sus Ate Protection Sdemlltei Street for nraet Licifng/Approval Inlanriallon. Malarial: CastAguios:201,210,219,250,260.501.510. 519. 51000, 5015, SillS and 5195- Oucito lion conforming to AS1MA4IS. Grade 65-45-12 Fabricated Slant Figures 391, 392, 393. 312. 313, 321. 327. 341 and 350- Carbon Stool, (Stoat 1W- fl are Schedule 40); (SIoux B'- Iti are Schedule 30), conforming to AS1M A-53 Glade B Piotattlon Csslingu: 1fon4ead orange paint Are brigade red (optional) usul-toud paint Hot dipped! gutuanlred conforming 1099339 9-153 Ordering Procedure When ptoekg an order. indicatu the tall product irune.Pleasaaptlarquxntlty,flga,nnambor, wall ihlcluuaos, and clss. Grinnell Grooved Piping Products. yukon, accasuorhcn and other products ore available throsghoottlwUs,caaad900dlnteroatlsnally, through a ureheert of diotdballoa cantors. You may write dIrec1' or call 215-3620700 for the dlsbllsular aoaruxt yelL Care and Maintenance The owner Is responsible for the Inspuft tooting, and noahllnoance of theirlirn protection system and deubma In uccerdairce with the paatsidsrixotImliotleidRmPrnibction Association (e.g.. NFPA 25), In idditlaru to the standards of any authwlty having bylalietlorL llreluiotultrrgcontroctererprodactmanafidurnr should be contacted relative to any questions. asybmpalmarotnitatbehirmsdletolymrroctad. It Is recommended that automatic oprbntdar systems bebopncod.toslad.arohunalntsbiedby a qualified Inspection Seuvtcs. Limited Warranty Pumatrats nmamdacliseut by Tym the PendiNG are wartordal irIrtta the erbyund Bsyr for for (10) trearolmlthfoEblmatorWwdwou1arusol4p wbepeblforaudpoupo%ibaixbouidnolrixlured raider eoniol use and uatvb. This smralfly WI apkntoa(lmmfmmthixe1ohigousrtbyTco RmProdieft libmansullbomforproductsor mrrrpeeects ,rremusrnd by crmrpanrbm not aiidLr,nMusnhwth1maAmPlXuartoerfor pedemmnua69hauebwnmft(xat tomb an.brroyerbNG88icn.cancoien.ouwl*fl lava AN bate ImMA rnnlrthbrd, utufdied or roidiorrdaraxidthspStsrdxufoof the Fioflamal Fan Pletoctbm Avsardeicn (M24 a91hatieudsafariydlrerAathelItovbg 2uticn. iltstodeicleusniilyTFaoPnndiafs fohodehcuIreole9hoeitivreØidcrtoFd.at TyuaflunPuodids'aobopulon. lycoPonPuodids rather assumes, liar ordbiorlotu ally person to smarrmforiteq,atlWnotlaibsonrrddlouwfth diesdidproduchorparbolproducts. TyanAun Rodmbddnotbomspamthtrspkd&Wstem uImbyroaeraambrddortcaoightebtbirotics wppfodbyBwerorBlqior'o rnproosritutbvon. IN IS CIENT SHALL TYOS ARE P0001931500 LIASI.E,IN CONTRACT, WRT.STRSTLIABILITY OR UNDER ANY OThER LERAI. ThEORY. FOR INCIDENTAL. INDIRECT, SPECIAL OR 00113NJ171ALOAWAGINGJJDIIS0UTIST UMAWIOLAS000HARGES.REGARDI.ESSOF WWEORREP0005WASIIIORPAR) ABOUT THE POSSIBILITY OF SUCH DAMAGES. AND O9$WIB1TSIIM.L1YOSAREPHOSUCIS LIABILITY 0(000) All AMOUNT EOIML ID THE SALES PRICE. Page2ei6 TFPtelO Figures 201, 210,219, and 260 /1L Son flOur, 501 Figure 210 9.9 cut-I fuel eir 225 Figure 280 Tissue 210 5 .*um,owolw.lowin.e aoncprseu. WE. u.n ol. Erz.vl., our .r• Eu. a,. u.n souls. 2 1 3.75 We 1.1 52 15.3 4.7 5M 1 axe 1ZJU a" . Iveunosol 4 Elbow Ftqure2lO nor Elbow Ftgureslg The Ftglae28O4 - Nominal moire, Lbn. boohee mm Lbn. Kg. 0T hrelwe mar lO.. Lb. Kg. B'Wr relies aim h5 Lbn. 88 TSF 44.5 0.4 I7B' 69.9 11 0.5 t7B' 69.9 0.6 3B' 22.4 Os 02 7F 44.5 0.5 r 69.9 tT - 0.5 B' 69.9 11 0.8 iM 224 -or 0.3 50.8 0.8 82.6 09 82.6 W.I. 1.2 3B' 224 0.4 57.2 09 7.0 95.3 54 3.75 £5.3 26 ii 2 4 0.4 SIr I ir i 572 1.0 95.3 5.4 99.3 26 25.9 05 SIr OY 2I3 TY Z 7 iM 63.5 l.a 108.0 20 ioa.o 22 224 05 105.0mm SIF 5r i7B' OT 217B' 11T - - 73.0 2.5 120.7 3.9 1207 5.2 - - -- SIr iIr 1 t Ur i - 76.2 2.4 127.0 3.9 127.0 5.4 29.4 1.2 isti nr z tur - - 826 3.5 133.4 5.5 133.4 4.8 - - Im my iss 82.6 3.5 139.7 5.1 (39.7 6.9 224 2.1 - 55 my my i -or 82.6 29 739.7 8.1 139.7 7.7 22.4 2.3 o 88.9 5.4 152.4 8.6 152.4 6.3 - - Im iem 1SI TNT F i s 88.9 24 16Sf 84 56Sf 11.6 25.4 3.4 6• SIr tor O lOT - lOT 7T 88.9 5.4 165.1 94 165.1 11.8 25.4 3.4 on 422 7.25 4 - - 705.0 10.4 1969 19.6 198.9 *4 - TIr lOT 115 108.0 70.4 199.9 76.6 7999 20.4 30.2 28 to' oem lOT O OT 115 120.7 14.1 228.6 27.2 228.6 32.7 31.8 9.1 SIr iOT l5 my 113 - ! for 251.0 L 2 42.0 31.8 JL E.elaucsm fl.!y(ul Pixel .L2!rooedaau1vaIe.it Size India, mm ' Fool tIela Feet UeNG Feet leterr Feet Vethu 42.4 0.6 0.3 T 1.5 IY aa - 48.3 0.7 TT 0.4 Tr 1.8 T 07 -o- 60.3 r 1.0 r 05 i 25 1.0 73.0 sr 1.2 m- 06 i 3.0 1.2 76.1., 1.2 1r 0.6 tOY a 7.2 66.9 T 1.5 1 07 tOY 3.7 1.5 - r 20 or 1.0 15.3 50 T 20 s14.3 so 2Z 1.0 TOY 50 $T 20 - 133.0... ,- 2.4 ,- 1.2 391 6.1 e.g 24 - 139.7.... .$y21- 2.4 1.3 SOY 0.1 24 -o- 541.3 or 2.5 ir 1.3 SOY 0.3 2.5 - 159.88. $T 2.9 T 14 391 95 165.1... 2.9 TT 1.4 391 75 iT 3.9 iT 20 !T 1.5 STY 76 iT 3.0 rro 4.2.0 10.04.0 EM0 10.0 0 IOYIF ~ oj S 4.02.0 lOTiTiTS 5.02.5 OT 61 12.60 TOYT 3.0 15.1 Page 1 of 6 September 2004 TFPISIO P"03016 Figures 5019 5101 519 and 51 ODE b E C ELMC9.E1 _L 4i.E4 F19ure501 Flgem510 Ftgme5t9 Flgum8I60E Flgim 601 FIgum 510 1 Flgwo 519 Pu510DE 45 9.63w 9,? Eleow lee 9,? 0,313 9510w -tate am On. bwhea mm mm the. Inchesthe. 8.0. 63633 mm kchoo mm Inthe. mm the. 46.5 0.4 69.9 05 -ri 69.9 09 _•_ - - - F t, 48.5 ii 05 sr 609 -i 0.5 r 69.9 - -Is 08 - - - - 5418 i 0.8 r 82.6 20 09 r 82.6 1.2 - - 57.2 1.0 93.3 20 1.4 i 95.3 2.6 05.3 50.6 2.75 69.9 1.2 63.5 6.6 z 508.0 20 r 108.0 3.2 1600 - 59.4 sr 69.9 -r- I.? 73.3 3.4 127.0 39 2.9 1397 127.0 82.6 6.5 139.7 3315 88.9 ,g- 5.4 163.1 8.4 ~ 'g 2l'0 3,ff i! 563.5 1L ,.600 i!1 i2 !LL !LL Figures SOIS, 510$ and 519$ C 1 I_fOE-I cfj 3t LriL Flguie501S F1gam5l0S Flwe619S 11 Ff13613 R133la,Ica (2!r.ed as Equlvale..l 6015.5109. & 5165 flkell Pipe) Size Inches reel Mete,,-Mete,? I ,- ,- 1.0 i:r60.3 05 73.0 1.2 T 06 jhF mm (2 08 _ ,- 1.5 IT99.9 0.7 1143 4 as .0 139 7 ir • 1.3 61 24 645.3 1.2 63 25 iT ETITT"'Iff.- 165.1- i iT 1.4 7.2 2.9 -- lT iT 168.3 1.5 7.6 3.0 3M? P1934016 TFPIO1O Figures 250 and 350 p El0e 1 Gall Figure 350 Sizes T to Figure 350 Fabricated Slzaeetol2 ADA CAP® Patented ggre3".01 eGmove Nonlnal 350 COnIllcRe.'.cer-G9.n Apse.WI. Nominal E59.9 E to S ADDS.WI.Nomsiol t.bs.Size Lbs.Inches IncheLbs.Sizebabe Inches ft nm Indiesnm 139.7..83 '0cC me I r10 211½I39.7.x4 1.2 .802 21402 5x1½ 3.50 SAO 12.1 F,gure 250 6x2½ 76.1...x1½ 552 61.5 7 603 127.0 5.5 761..o2 532½ 604 Et3E1 M9 20 r4.S 3s1/. 2.50 1.3 3.50 5.00 11.3 63.5 0.6 88.9 627.0 5.6 331/. 2.50 1.3 • 3.50 5.00 T 63.5 06 889 906 l27.0 4.9 2.60 1.3 4.00 6.00 21.9 312 93.5 06 03 1014 552.4 10.0 3x2½ % Fabricated 965.1x4 BAD 26 1005 3x76.l 1951..15252 101.6 Is 1008 IRA 9.6 3.00 2.2 • 4.00 • iT 75.2 6.0 6 .0 602 105.8 . 2.7 1008 653.4 89 376M 652½ 1204 1772 a 52.7 350 3.3 4.00 6.0 7.00 30.0 E 78.2 . 6.0 hT 1 101.62.7 5772 13.6 6 33.0 -400 6.0 750 25.0 79.3 to 6113 101.6 27 1206 573.6 12.7 3503.2 4.00 5.9 752 . 5.5 604 .101.6 27 12110 577.8 '15.0 350 2.6 -9 782 6.2 80139.7., 101.6 29 - 4.00 6.3 El I Nondsal Takeout QImqF VIN. in rnd Not tncPes NPr Inches Inthee mm mm e, 1 che s - - tr -or I Oj ILL ILL -1.25 1.7 0.77 48.531.844.5 '.0.3 ILL ILL 1 1.37 2.00 20.86 2. n 0551, 15913 1.25 1.5 9 -0.92 ILLLL 2.375 l.25 .1.75 9 0.92 3 ILLLL1.37 21.06L-1.47 9 -1.25 0. --•2.875 1.47 1.97 9•730 50002.00 3.20 IL Pow 5 old TFP1810 Figures 391, 392,393g 312 and 313 Figure 391 Rgum 392 flj• i4 Figure 393 Figure 312 out 9ZnI-- Figure 313 Flgure939I. 392 8114393 Flgure312 22%' Elbow R9we313 IiV. Elbow - - - - morninal IrohoSE WI. Ap CODE 119111011 A990. WL 1.11$ C IDE 11911919 9985. WL Lbs. SIM mm K9, Iffm go. Arm AL -- IV' 4.00 -- 0.0 -- 1.75 0.4 - 1.39 0.4 1012 0.4 44.5 as ss.: 02 • 0.00 05 175 0.5 126 0.5 101.6 04 44.5 02 35.1 02 ir US -sr- 126 1016 as 47.8 as ss., 0.3 SW 4.00 T 2.00 0.7 1.50 1.1 101.6 as Sad 113 aS: 0.5 31 -z - IA ¶26 1.2 101.6 1.1 572 8.6 al 0.5 8.00 55 2.63 52 1.75 32 152.4 55 508 1.1 44.5 1.0 0.00 2.00 0.8- 5r- 152.4 3.4 73.2 1.9 508 1.5 ___ O W- 92 513 55 2.00 4.0 152.4 4.3 795 2.5 508 if 1W 14.3 326 11.1 2.00 8.7 154 04 93.6 8.0 508 35 9.00 1F ir 14.0 2.13 9.1 203.2 122 112 6.4 58.1 4.1 426 255 -- LL 152 0 150 572 2.6 Figures 327 and 341 -CbE rri Cu' Figure 327 .1. 11.1 1.1 I Figure 341 1> ) P48.0010 TFPIOIO FIgure 321 Gem00l Notes: El. lIre DesIgsufs reupensthllly ID Select p100.450 SuItable for the Intended service end ID ensure S 6reIpmeswomtiigsendpodomiazwedutabtcleoesed. Nessmedw14uor0045Wehwto94Ibsbretruc4eno 9001 (04.1000). Never remove any piping component or correct or 010491, any piping tloficlenced without first depreseurIDrg wrddrabilrrgllreuyutent. Noterlolerrdgaoiretsebctbn.IuuidboveiitIed lobs 001r009510 for Ore opeclib app1los. Certified Company. TYCO FIRE PRODUCTS. 451 1110101 Cannes Avenue. Lansdale. Penzluyiuerda 10940 P414.4 U.S.A. Figure 321 OWE DOE Size ledwa Lbs. Size lrdrao AWLLbs.. Inches aim Was _jg, 1041s5 mm _j,, Itexitexita 1W 2.0 00004 am 25.8 _______ 82.6 165.1 12.1 WE 20201% 5.25 -r- Sx6x5 am 27A _________ 82.6 1.2 165.1 12.2 2%02%nite 3'rS 42 858 02 93.3 1.6 196.9 10.4 14402½ site 3.75 4.2 asSes 953 1.9 465.8 18.6 280804 __95.3 2.195.8 10.6 %W1öT __108.0 3.4 490.6 16.7 11 7 __102.0.2.5 ________166.8 P 16.8 ½I0e1002 _1080 56 228.6 9.00 r 25.9 1,,oioa __127.0 4.4 228.8 26.0 ½ 1W 100 1004 0.50 127.0 4.5 2.28.6 261 1 15T 1001005 i 127.0 4.6 228.6 262 40482½ Sao 1013 1051000 127.0 4.7 228.6 262 540 isa loeloeB 089 127.0 4.8 228.6 20.5 5x552 1281203 10.00 00.2 159.7 6.6 254.0 38.4 55502½' 1281324 I39J .6.7 2500 36.5 1W 12e12x6 135.7 2.9. 254.0 38.6 50504 2 1201200 .10.00 ••• 139.7 7.2 254.0 38.7 00082 0.50 26.5 1201208 10.00 -ii 16$.! 11.9 254.0 48.5" 00002% i5 12012o10 10.00 1T 16$.1 12.0 254.0 41.6 00053 -- __L UP. ISTRUhIrThe Original Metal Framing Part No. 40 anced Search k(Add To Cart ) Dooad CAD Data 13I000T - 1-5/8" x 1-5/8", 12 Gage; Slotted 1W - L- 22.2 Slots are 1W (2S4 X 31e (14.3) Hl 2c5non c 23.3 1 41.3 Channel Selection Chad Notes: Related Channel Nuts Above loads include the weight of the member. This weight must be deducted to arrive at the net allowable load the beam will support. Finishes: GR EG i:IG ZD EL EA aS a Long span beams should be supported so as to prevent rotation and twist. Weight: Allowable uniformly distributed loads are hated for various simple 185 Lbs/1 00 Ft spans, that is, a beam on two supports. If load is concentrated at the (275 Kg/I 00 m) center of the span, multiply load from the table by 0.5 and corresponding deflection by 0.8. AdditionaLSpecitications The lateral bracing factor should be multiplied by the load to determine the load retained based on the distance between lateral Elements of Section braces Area of Section - 0.555 in2 (3.6 cm2)' Bearing Load on Channel: Axis 1-1 LOAD LOAD LOAD Moment of Inertia (I) - 0.185 10 (7.7 cm4) O Section Modulus(S) - 0.202 In (3.3 cm3) Radius of Gyration (r) 0.577 In (1.5 cm) Max Load Max Load Max Load Moment of Inertia (I) - 0.236 In4 (9.8 cm4) 5()09 Lbs 8.000 Lbs 3,500 Lbs Section Modulus (S) - 0.290 In' (4.8 cm l) 2,268 Kg 3.629 Kg 1.588 Kg aOiuiTt3lSlhtei 2005 Uiimma. All Rights Reseivcd tqco Ieczricai& UdMdV Vwlcmukorseiukoruthsuid Ceipmulimi aedtce lie aflhlleice Is. the Uelrcd Staw wdforothceccenhileL lMera/Poduczs h+fwllwu,u, ivcfriif fl,-rs.'uirnIr.o+ ,l-+01 r (V1,D=D1 ()AAT '7P)1 P3AA0 pmkdm 1061 990wava901re17 DIMENSIONS IRS CARBON STEEL PIPE - FIRE PROTECTION VALVES Series 728 FireLock Ball Valve PRODUCT DESCRIPTION The Series 728 Ftret.od valve be standard past. enderlry Valve that is ULJFM rated for 350 psi (2410 lcPa) service In all sizes. Availeblewith ground or threaded ends (NPI). the valve body and Qearbox are brass die cast. The ball Is Civeme plated bress with o 6rass stem. WE seals aid ease of operation and provide a corrosien.freeseal.meslreandlneddedgnprovldesexceHentflew, charactedstic6 which exceed UI. SpecifIcation 1091 and FM Approval Standard 1112. The valve Is approved for Indoor arld outdoor use. -- APL OLE I H? _I. C I I I 0 I H F II4I1th I CU I N51Iai 294 72 I I OCt I 093 1 2.31 5.22 Ii lllld.11ttsl. 197 I I.liaI. 2.37 SOS 562 1.aa 553,41106 I 5.1 2.5 3.31 I 6.64 151 I 1.15 liv I iso 59151165160 I 2.30 I I 5.8Pl.tlbl.X1Ed. 2.47 I 3.39 5.62 I 196 .3 1 41 1 ,2 I 1.60 L42 I 1.3 I 1.71 I 2.66 I 65 3M 2.66 I 3.39 iaa I 1.03 I 66 15211.a.xlic. 97 5 163 15.1451 sal sal 170 7.15 702 I 1.71 I so 51 4.32 I 2.07 lao I 3.40 iso I a.satild.tltal. I 3.05 172151 I 5.39 062 I 196 13710159 1 I 2.16 JL75 I 6.25 I 1.10 I 197 I 2.30 I 7.5l'6.XGre. 3.9 7.25 I 3.58 I 3.39 562 I 196 I 3.19 154 I 119 129142119106151 143111151 1 165 I 675 I III 1.35 I inn 1 53 1.0 1 51 1 11 1 51 2.71n.eo I 6.51'I.GreXGlv. 14 7.25 I 3.39 592 I 1.06 14310151 1 I 3.19 1.25 I 7.50 1.71 2.35 11 . ZGCVXGII. I 3.16 I I 100II. I 3.39 5,62 1.00 I 3.19 431511 IS Isa 143.411e1 1 63 1O17. SWITCH AND WIRING lopsndaaly 65,0106 Mal supendsory switch contains wA 5190)0 pale, doable 115ev,. pre.swed switches. Switches are rated: lo amps 51 125w 250 VA060Hz 0 50 amps 51 125 VOC 0.25 ampS 51 250 VOC 2.6 amps 5124 VOID sapsrvlae,y 8.11081 WIring P. Re-wired Switches Switches supervise valve Is 'open p051500 One swItch has we #18 MTW wires per terminal. 943106 permit complete supervision of leads (refer to diagrams and note belav). The second switch has one #1BMtW wire per terminal. 1150 double circuit prorddesfealbflhlyw operate two electrical devices at separate locallon5. such as an Indicating light and an audible alarm, in the area that the valve is Installed. A#14MiWground lead(green) is provided Switch 01 Si Switch 02 52 (Nonna9y Oosed:(2) Blue Yell So( NormatyOpen: (oW 2) Brown (Cranmon: (2) 4 Normally Closed: Blue with Orange Stripe Normally Open: Brawn with Orange Stripe Cammom Yelow with Orange Stripe aoVJTCIIIIECMM I 'T NOTEt The above diagram shoes a connection between the common terminal (yellow.S1) and y51low with.wange sirlpe.52) and the irsonaly dosed terminal (blue-Si and bble-w4th.erange stripe-S2). In this example. the Indicator 11061 and alarm will slay on until the valve Is fully open. When the valve Is rally open. the Indicator light and aSem will go out Cap cit any tmused wines (e.g. brown and brown with orange. stripe). MATERIAL SPECIFICATIONS PERFORMANCE V.19. Bedift Bronze PSTM 8.584 May 844 Blilt Cloeme Plated Brass 80601; 316 Stahttess Steel Seal: (TFE) lelraflaoroethplene Se.in 18125 Brass ASTM 01-18 C36000 Quadrant Olin 316 Stainless; Steel Main Slam: Brass ASIM 816 C36000 Worm Gain #0511144 Steel am am I - rIboI5 tveadativnaa - II 92 ,. t'i.crca.excroaso I i.a I 04 59 463 I'l,thOeCeOQCeCS I 10 I 63 1.7 I 1.2 2lllnedxtlnned 05 II 02 . II HammexlflzwflwWa66.sWlrnoalc-1291751511.iinslCai j4tauiicr tmnp60on800b.rawees.00un9taa96carwar$1wSeoxeboH90I65L 06thn.maweSeel00n05lnthmom00yr65n. sn090twevL5151.pr6060Wa51toarSe.069g3s60awned9.,.19ee59uweamdemenIwn6g06l5aSew 2 Series 728 FireLock Ball Valve i EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 (760) 310-6122 FAX (760) 798-0556 Hydraulic Design Information Sheet Name: CARLSBAD COLLISION SPRAY BOOTHS Date: 44-11 Location: 6030 AVENIDA ENCINAS Building: EXISTING System No. 1 Contractor: EPIC FIRE PROTECTION, INC. Contract No. Calculated By: RAB Drawing No. 1 OF 1 Construction: 0 Combustible Non-Combustible Ceiling Height 10 Ft. NFPAI3: [1 NFPA 231 El Other (Specify) 0 Specific Ruling SYSTEM DESIGN El Light Hazard Ordinary Hazard Group 0 NFPA231C: Figure: D 2 D 3 JK Extra Hazard Curve: Made By Date Area of Sprinkler Operation ENITRE BOOTH System Type Density .40 Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 100 AQ FT MAX Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make TYCO Model ELO Hose Allowance GPM: Outside 500 Size .64" K-Factor: 11.2 Rack Sprinkler Allowance NA Temperature Rating 200 DEG CALCULATION SUMMARY GPM Required 224.76 PSI Required 55.48 At Base of Riser "C" Factor Used: Overhead 120 Underground 150 I WAN II 1 !J RVA Water Flow Test Pump Data Tank or Reservoir Date & Time B.O.R. CALC Rated Capacity Capacity Static PSI At PSI Elevation Residual PSI Elevation GPM Flowing Well Elevation 0 Proof Flow GPM Location SITE Source of Information [(]VJT8 LI] II i wai tuj Location - Aisle Width % Rack Commodity SPRAY BOOTH Class - Storage Height Area - Storage Method: Solid Piled % Palletized Rack U Single Row 0 Conventional Pallet El Double Row 0 Slave Pallet 0 Multiple Row El Open Flue Spacing In Inches Longitudinal __ Transverse Horizontal Barriers Provided 0 Encapsulated 0 Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. O Automatic Storage El Solid Shelving I CARLSBAD COLLISION BOOTH .40/ENTIRE BOOTHf Sigma Dynamics Corporation 7700 Supply I Demand Graph iamu • III__ _________________ --7=-W Pressure -55. 48 PSI InfiniteFlow______ iiiu• ________________ ___________________ ______ ________ ____ 'iii•••__________________ _____________________ • __________________ ____________________ uuuu•___________________ -- _____________________ INN iaia• ili!I•____________________ iuia• uirnua 'piuua 100"ll -300 Isis LsI' :lsls 900 Water Flow (GPM) System Demand.. Sprinkler Demand 55.48 PSI € 224.76 GPM Additional Flows 0.00 GPM Hose at Source 500.00 6PM Total Demand 55.48 PSI @ 724.76 GPM 04-04-20.11 PAGE 1 SUBMITTAL SERIAL NO:2932HY7 CALSBAD COLLISION BOOTH .40/ENTIRE BOOTH SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW ..KFACTOR PRESSURE 10 40.08 35.42 11.20 12,81 11 39.51 35.42 11.20 12.44 12 37.18 35.42 11.20 11.02 13 36.64 35.42 1.1.2.0 .20. 70 .14 35.94 35.42 11.20 10.30 15 35.42 35.42 11.20 10.00 TOTAL WATER REQUIRED FOR SYSTEM 224.76 GPM OUTSIDE ROSE STREAMS AT 0 500.00 GPM, TOTAL WATER REQUIREMENT 724.76 GPM PRESSURE .REQUIRED...AT .0 .5.5.4.8 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.0.0 PSI MAXIMUM VELOCITY FROM 5 TO 10 19.60 FPS SUBMITTAL SERIAL NO:2932HY7 04-04-2011 PAGE 2 CMUSBD COLLISION BOOTH .40/ENTIRE BOOTH Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Sununazy From, To GPM IN Devices Ft PSI/Pt PSI 13 15 .1.53.6 .L .12.0.0 C=120 PT .1.0.00 .( 15) Q 35.42 P=O F 0.00 PE 0.00 BN T 12.00 0.0585 PF 0.70 11 13DQ 36.64 1.536 L 8.00 C=120 PT 10.70 ( 13) Q 72.06 F=0 F 0.00 PE 0.00 .BN . T 8.00 0.2176 PP 1.74 6 11D0 .39.5.1 .1.536 L .2.00 .C=120 PT .12.44 .( 11) Q 111.57 F=T F 8.90 PE 0.00 BN T 10.90 0.4885 PF 5.32 PT 17.76 ( 6) - 12 14 1.536 L 12.00 C=120 PT 1030 ( 14) .Q 35.94 F=0 F 0.00 PE 0.00 BN T 12.00 0.0601 PF 0.72 10 12DQ 37.18 1.536 L 8.00 C=120 PT 11.02 ( 12) Q 73.12 F=0 F 0.00 PE 0.00 BN T 8.00 0.2235 PP 1.79 5 10DQ .4.0.0.8 1.536 L .2.00 C=120 PT 12.81 ( 10) Q 113.19 F=T F 8.90 PE 0.06 BN T 10.90 0.5018 PF 5.47 PT 18.28 ( 5 ------------------ 6 2.203 L 6.00 C=120 PT 17.77 ( Q 111.57 F=O F 0.00 PE 0.00 FM T 6.00 0.0844 PF 0.51 4 SDQ 3.13.19 2.203 L 26.00 C=120 PT 18.28 ( 5) Q 224.76 F=T,4E F 30.80 PE -6.50 FM T 56.80 0.3082 PP 17.51 3 4 .2.2.03 .L 42.00 C=12.0 PT 29.29 ( 4) Q 224.76 F=0 F 0.00 PE 0.00 FM T 42.00 0.3082 PP 12.94 2 3 3.314 L 28.00 C=120 PT 42.23 ( 3) Q 224.76 F=T P 18.90 . PE 0.00 FM T 46.90 0.0422 PF 1.98 1 2 6.357 .L 184.00 C=120 - PT 44.21 .( .2.) Q 224.76 F=E F 12.57 PE 0.00 FM T 196.57 0.0018 PF 0.35 0 1 . 6.357 L 25.00 C=120 PT 44.56 ( 3.) Q 224.76 F=BV,E F 25.14 PE 10.83 FR T 50.14 0.0018 PP 0.09 PT 55.48 ( 0)