Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; ; AS090085; PermitCity of Carlsbad. Sprinkler Permit Permit No: AS090085 1905 CALLE Job Address: Status: ISSUED BARCELONA • Permit Type: SPRINK Applied 7/22/2009 Parcel No: 2550120400 Approved: 7/22/2009 Lot #: 0 • • • Reference No.: • • • Issued: 7/22/2009 PC #: Inspector: Project-Title: ULTA 01 FIRE SPRINKLER PLAN REVIEW & INSPECTION ULTA Cosmetics Applicant: • • • Owner: A & D FIRE SPRINKLERS, INC..' • BORDERS INC FOURTH QUARTER 2ND FLOOR 11465 WOODSIDE AVE • C/O DELOITTE TAX LLP SANTEE, CA 92071 P 0 BOX 131071 CARLSBAD CA. • 619-448-1962 Fees ($) Add'I Fees ($). • Total ($) Balance ($) •• 235 .0 235 • 0 lit '4 ___ FIRE SPRINKLERS INC. UL TA CARLSBAD TI 1905 CALLE BARCELONA SUITE 110 CARLSBAD, CA 92,009 FIRE SPRINKLER SUBMITTAL MANUFACTURER DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. AS 0100t57 FILE COPY 4 tilco/F/re & Building Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB - 2.8, 4.2, 5,6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage S General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 114 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.0K, 3I4'NPT 1Y4231 - Pendent 8.0K, 3/4'NPT Page 1 of 10 APRIL, 2006 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 7/16 (11,1 mm) 1/2° ** NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE 2-3/16° (55,6 mm) 1-1/2" (38,1 mm) = S Page 2 of 10 TFPI7I 7 FLATS STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16" (11.1 mm) NOMINAL I 11/ — 1 _ 1 MAKE-IN 2-3/16" 'WRENCH (55,6 mm) 1/2" NPT** SSP DEFLECTOR* h — 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression 7 - Bushing orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI 131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 7/16" (11,1 mm) STYLE 10 or 20 ** NOMINAL RECESSED 1/2 MAKE-IN ESCUTCHEON NPT SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA SSU * DEFLECTOR ;r(N mm) 1 L ' -IN 2-3/16" NAL I WRENCH (55,6 mm) FLATS 1/2" NPT** I 6* PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT S 6* ESCUTCHEON 1/2"(12,7mm) PLATE SEATING ** NOMINAL SURFACE NPT MAKE-IN 25!16" \TJ (58,7 mm) 1-9/16" I (39,7 mm) SSP DEFLECTOR* PENDENT STYLE 30 or 40 RECESSED ESCUTCHEON WRENCH FLATS I - 2-7/8" (73,0 mm) DIA. - RECESSED PENDENT SSU * DEFLECTOR 1/2" 1 (12,7 mm) I NOMINAL I MAKE-IN I 2-1/4" (57,2 mm) 3/4 NPT** 6* TFPI7I Page 3 of 10 T_ 2-3/16" (55,6 mm) T STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR I 7/16" (11.1 mm) 1 Ill I I II NOMINAL I E-IN RENCH J,j__ 2-3/16" FLATS (55,6 mm 1/2NPT** ESCUTCHEON PLATE SEATING SURFACE 7/16(11,1 mm) 1/2" ** NOMINAL MAKE-IN NPT SSP DEFLECTOR* h"— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 11 UPRIGHT 1- Page 4 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** IPOLVESTER 2.8 1/2' PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175°F179°C Yellow. 200°F/93°C Green 286°F1141°C Blue NPT 135°F/57°C Orange 1, 2, 5 RECESSED PENDENT (TY1231) Figure 5 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 135°F157°C Orange RECESSED PENDENT (TY1231)°° Figure 6 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (1Y2231) and UPRIGHT (T''2131) 135°F157°C Orange 1,2 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 28&F/141°C Blue 135°F/57°C Orange RECESSED PENDENT (TY2231)° Figure 7 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 135°F157°C Orange RECESSED PENDENT (TY2231)° Figure 8 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/ps1112 (40,3 LPM/bar112) K = 4.2 GPM/psi1l2 (60,5 LPM/barl'2) K = 5.6 GPM/p5i112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ............Bronze Button ........ Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw' .....Bronze Deflector .......Copper/Bronze Bushing (K2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. S S S TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED WHITE POLYESTER I LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F/68"C Red 175°F/79°C Yellow 200"F/93°C Green 286"F/141"C Blue NPT 135°F/57°C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231)* Figure 9 155°F/68°C Red 175"F/79°C Yellow 200"F/93"C Green 135°F/57°C Orange 1,2, 3, 4,5 I I I I 1,2,4,5 I Green N/A RECESSED PENDENT (TY3231) Figure 10 155°F/68"C Red 175°F/79"C Yellow 200°F/93"C 8.0 3/4', PENDENT (TY4231) and UPRIGHT (TY4131) 135"F/57"C Orange 1,2,3,4,5,6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200"F/93"C Green 286°F/141"C Blue NPT RECESSED PENDENT (TY4231)" Figure 11 135"F/57"C Green 1,2,4,5 N/A 155"F/68"C Orange 175°F/79°C Red 200°F/93°C Yellow RECESSED PENDENT (TY4231)** Figure 12 135"F/57°C Orange 1,2, 3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93"C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-4284444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD BRASS PLATED I POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/40 RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE 174 Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C to 3/32 inch (2,4 mm) for the 2860F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I 2-7/8' DIA. 5/8±1/4' (73,0 mm) 3/4(19,1 mm) - (15,9±6,4 mm) - 2-1/4' DIA. 1/4' (6,4 mm) PLATE SPRINKLE4R*1 FITTING 1/8' FACE OF MOUNTING (3,2 mm) MOUNTN SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)I TY-FRB 13/16"(20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. - 5/8±1/4' (73,0 mm) I 3/4(19,1 mm) (15,916,4 mm) .,_...... 2-1/4 DIA. I 1/4(6,4 mm) I FACE OF MOUNTING I PLATE I FITTING 118' I SPRINKLER I / (3,2 mm) MOUNTING/ f f SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4(19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 7 of 10 - 2-7/8' DIA. (73,0 mm) 1/2±1/8' I 1/2" (12,7 mm) 1 (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I SPRINKLEqR PLATE I FACE OF 572 mm) MOUNTING I FITTING / 1/8 (32mm) SURFAC 6'(33,3 mm) MOUNTIN CLOSURE SERIES TY-FRB 1-1/16"(27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 1/2±1/8' I (73,0 mm) 1/2"(12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I I FACE OF (572 mm) MOUNTING I SPRINKLEqR PLATE I FITTING 1/8" ± 32mm) MOUNTIN SURFACESERIES 1-1/4" (31.8 mm) I CLOSURE TYFRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 0 Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random El Page 8 of 10 - 2-7/8' DIA. - 5/8±1/4" (73,0 mm) I 3/4"(19,1 mm) - (15.9±6.4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I I FACE OF mm) MOUNTING SPRINKLER PLATE I FITTING (3,2mm) -1/8" MOUNTING,,,//// I I f SURFACE SERIES 1-1/4"(31,8 mm) I CLOSURE TYFRB 3/4"(19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8"DIA. 5/8±1/4" (73.0 mm) 3/4"(19,1 mm) (15.9±6,4 mm) 2-1/4" DIA. .__.I 1/4" (6,4 mm) FACE OF (57,2 mm) FITTING M SR I MO PLATE PLAI UNTING MOUNTING I SURFACE CLOSURE SERIES 1.5/16" (33,3 mm) TY-FRB 13/16"(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I 2-7/8' DIA. - 1/2±1/8" I (73.0 mm) 1/2(12.7 mm) r (12,7±3,2 mm) 2.1/4" DIA. 1/4" (6,4 mm) I SPRINKLER PLATE FACE OF 57.2 mm) ] MOUNTING I I FITTING 1/8" (/#mm) I \ MOUNTING SURFACE SERIES 1-1/4" (31.8 mm) CLOSURE TY-FRB 1"(25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 1/2±1/8" (73.0 mm) 1/2"(12,7 mm) r (12,7±3,2 mm) 2.1/4" DIA. 1/4" (6.4 mm) FACE OF I (57,2 mm) MOUNTING I SPRINKLER PLATE I FITTING 1/8" / L32 m) I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm TYFRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT I 0 sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 9 of 10 EI P/N 57-XXX-X-XXX MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4°NPT) TY4131 391 8.0K PENDENT (3/4°NPT) TY4231 I I L 135 SPRINKLER I 155 175 200 286 RATING 1 NATURAL BRASS 155F/68°C 4 WHITE POLYESTER 175°F179°C 3 WHITE (RAL9010)* 200°F/93°C 9 CHROME PLATED 286F/141*C 7 LEAD COATED * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. . In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor Page 10 of 10 TFPI 71 I TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IIUUI.LU / cI1UUIU Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-1O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l"- 8") pipe and Sch-40 (1"- 2k") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcsl WI/Lilt (21') WI/Lift (24') WI/lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1V4 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1½' 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch40 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lilt (21') WI/Lift (24') WI/Lilt (251) In; mm in; mm Lbs/Ft; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 279 2.1 2.70 91 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2° 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2' 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule- lO/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory • test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbio logically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Schedule- 10/S chedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tLICQ/Flow Control @ <~> 9 Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 '11350 Norcom Rd. • Philadelphia, PA 19154 llied TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S5 -3 1 . v; B EJA Outside Head II AiLBtar Flu Preduds Olvivinu uS Anvi' ternntIant I Ductile Iron Submittal Sheet Nominal Anvil Item Universal Dimensions Style Approx. Size Number Dumber wt. Each A B C In (tam) ,. '' '/ i (iñn) In (ninj ' 'In (m) 5.. . ct6s Ikg) 1 x ½ 840600001 DBUSH31 0.15 0.25 1.42 Outside 0.22 25 15 . 7903 .35 34.O 1 x 840600019 DBUSH32 0.75 0.25 1.42 Outside 0.11 25 .0 20 !9.0 63 36.06 11/4 a I . 840600027 DBUSH43 0.80 0.28 1.16 Outside 0.28 7.11 0.13 1%x I 840600035 DBLISH53 0.83 0.31 2.00 Outside 0.45 ,W25 . 21.08 7.814 50fl0 1½x 1% 840600043 DBUSH54 0.83 0.31 2.00 Outside 0.30 4032. 2105 1574 2 x 840600050 DBUSII63 0.88 0.41 1.95 Inside 0.67 70414 49.53 0.30 2x 11,14 840600068 DBUSU64 . 0.88 0.34 2.48 Outside 0.73 5799 033 2x 11h 840600016 DBUSH65 0.88 0.34 2.48 Outside 0.61 SO:s 40 22.15 429 B t A Inside Head Ductile iron threaded fittings are UL & ULC listed & Dimensions conform to ASME 816.3 Class 150. Factory Mutual Approved For 500 psi service. Threads are NPT per ANSI/ASME 131.20.1. Ductile iron per ASTM A536 Class 65-4512.. APPROVED ForListing/Approval NOTICE: Ductile iron listings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron listings should be tightened three turns beyond hand tight, but no more than Four turns. details contact your AflulIStarTu Representative. Project: [Date: I Phone: [Architect / Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cost & Ductile Iron Fittings For the latest UL/IJLC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.0020 go to www.anvilstar.com or contact your local AnvilStar representative AiLtr - Fire Products Division at Anmi' ivtniniianui RNVIL Ductile Iron Submittal Sheet I Al"s I Anvil Item Universal tau M k' or tag In (mm) Approx. Size Number (lumbar .Pressure Mt. Eoch A B 11n 4mm),. ' t?51(kP&h im) In(m Lbs ?k) 1 840000004 DB90033 500 1.50 1.50 0.62 3450 38W 33.10 0.28 1% 840000012 0890044 500 . 1.75 1.75 0.90 1½ 840000020 0890055 500 1.94 1.94 . 1.20 3450 49.216 0S6 2 840000038 1 0890066 500 2.25 2.25 1.85 50 3650 5:tJ5 51)5 034 Ductile iron threaded fittings are UL & ULC listed & Dimensions conform to.ASME B16.3 Class 150. Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B1.20. 1. APPROVED Ductile iron per ASIM A536 Class 65-45-12. For Listing /Approval details contact your NOTICE: Ductile iron Fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile 'AnvilStar'14 Representative iron fittingi should be tightened three turns beyond band tight, but no more than four turns. _ Project: . . Date: Phone: Architect! Engineer: Contractor: . Address: Notes 1: . . 4NWotes 2: - SPF Cast & Ductile Iron Fittings For the latest UIJULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.0010 go to www.anvilstar.com or contact your local AnvilStar representative ,, ................. 91 VIL Ductile Iron Submittal Sheet Nominal Anvil Item Universal Max. Dimensions Working Approx. Size Number Number ____ ________ __________ 'Pressure w. Each A B C _______________ PSUkPoi1 In(mj ih(m'2i 1nim) Lbsc(kg)ks 1 x I z 1% 840004238 01334 500 1.61 1.67 1.58 0.98 25x25;'32 5450 42M 441 40.13 0A4 1 x 1 x 1½ 840001246 01335 500 1.80 1.80 1.65 1.16 1'Axlxl½ 840004295 DT435 500 1.88 1.80 1.82 1.42 2.5 340 4i.7S 4S.1 4a.2 1114 1114x11h 840004337 01445 500 1.88 1.88 1.82 1.45 ____ 3430 41•75 4175 1',4x1'ix2 840004345 01446 500 2.10 2.10 1.90 1.15 ____ 3450 . 5334 53.34 43.2d 019 1½x1½z2 840004436 01546 500 2.16 2.10 2.02 1.90 4o3?if co ____ 345n 54ju 53.34 51.30 083 1½ x 1½x 2 840004485 D1556 500 2.16 2.16 2.02 1.98 413x48';SO 34c0 S.I.S. 54.86 31.30 010 A 1 B -. Ductile iron threaded Fittings are UL & ULC listed & Dimensions conform to ASME B16.3 Class 150. Factory Mutual Approved For 500 psi service. Threads are NPT per ANSI/ASME B1.20.1. Ductile iron per ASTM A536 Class 654 APPROVED512. For Linting/Approval details Contact your NOTICE: Ductile iron livings have higher tensile strength than that oi steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile AnvilStarlm Representative. iron fittings should be tightened three turns beyond hand tight, but no more than four turns. Project: Date: Phone: Architect / Engineer: . . . . Contractor: . Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest UL'ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.060015 go to www.anvilstar.com or contact your local AnvilStar representative . Nominal Anvil Item Universal Max. Working Dimensions Approx. Size Number Number Pressure WI. Each A B 'In(miiiP'4 jJ3 jPSIikPo)J tn (mA) F*In(ntrn) *1 040 840003164 01333 500 1.50 1.50 0.85 5 . - 3450 3&!0 18.I0 0.39 11,14 840003172 01444 500 1.75 1.75 1.22 44.45 0.55 1½ 840003180 01555 500 1.94 . 1.94 1.55 41) 3430 49.21 4 f. 21 0.70 2 840003198 01666 500 2.25 2.25 2.45 B A -'-h-- A ALBtr Fire Prnducls Diinan d jwIr Inleniatbuvi Ductile Iron Submittal sheet Ductile iron threaded fittings are UL & UIC Listed & Dimensions conform to ASME B 16.3 Class 150. ® (j Factory Mutual Approved For 500 psi service. Threads are NPT per ANSI/ASME B1.20.1. APPROVED Ductile iron per ASTM A536 Class 65-45.12. . For Listing /Approval details contact your NOTICE: Ductile iron Fittings have higher terssile.strength 1hon that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile AnvilStarTm Representative. iron Fittings should be tightened three turns beyond hand tight, but no more than tour turns. Project: . Date: Phone: Architect I Engineer: . Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For, the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06-0013 go to www.anvilstar.com or contact your local AnvilStar representative Ductile Iron Submittal Sheet . Nominal Nominal Anvil Item 0nivecsel ft . ° Dimensions lsetktng _______________________ A PP lOX. WI. . Anvil lies . Untversol titus. n Working tniun.tons Approx. Size Number tivinber Each Size Wombat Number Pressure - Each B A I In. (itim) ) In. (mm)In. (min) L6s.(kg) In. (mm) In.PSI PSI () In. (mm) (mm) In. (aim) Lbs.(kg) 84000i°6 UTT T Tö T I I' 1 T7 84O0O1O4 80004428 Db4 500 165 153 lEO kpl $;96 ii T lxi 17 1 xl 4 40flO443o Y6 k - 84000121i 0131 T& 011 i7lkxt 84000d444 t 5i 500 141 141 I lô 115 1 xl X/i 840004226 01332 TT T 11W 1½e 1½x ¼ 840004451 b1W 500 1.52 1.52 1.15 1.24 It. Ix l'i 840004236 01.334 iir iii TT TF T1 I v la I 840004469 11 500 103 105 ISO T.30 1 a It 11 ' 840004246 ir -r TF 11 TW fIA,TT51xI4 840004477 01554 500 182 TT 'TT ______ Tsax1 t''z 840004253 1$T1T -'!iiö TW T3r 012 1'u1"x2 840004485 01556 3iii r1r ir -ir iii 1¼x 1 x¼ 840004261 01432 5 T13 11T 1T1 T 2x 1 :e2 840004495 11 3 500 2.25 2.02 2.25 2.15 1'/vxiul 840004219 1W 500 TW• 'TF 11W T 2x1¼x2 840004501 500 11W 2.25 2.30 .5 1 ,l I I 50 _5_1 '471__...._:_ i__ lViuixl% 840004287 0144' 500 1.75 1.67 1.75 1.08 2x1½u½ 840004519 116 T 11W 1.41 1.88 1.50 3 a ___ 'v3 4 _________.___ it, ul u lth 840004295 01435 500 1.88 1.80 11T iTT 2u1'.x¼ 840004527 i'2 500 1.60 1.52 1.91 -F6-2- IN;lt/4x½ P ( IS . 55 10 11 840004303 111T 1U Tt lIT 131 ir 2x1½x1 ________ 840004535 iöi' 1.73 1.65 2.02 1.64 - .a4 3111.04 s - 3450 IL..! ___ 1'/4x P/va ¼ 840004311 01442 500 1.45 1.45 1.62 02' 2x l 'ill u 11/ 040004543 01654 500 1.90 1.82 2.10 1.80 i'A x11/ix1 !!!__.L_.P' _450.Iji_L_!L..4L... 1 840004329 01443 500 1.58 1.58 1.61 03 2x1½x1112 840004550 D1655 500 2.02. 1.94 2.16 2.00 t I '. 0 L 5 4 r I 4' .122... L _8_ ..ii..... 1¼x11/4 x1½ 840004331 D1445. 500 1.88 111 lIT i1' 2x1½u2 _________ 840004568 01656 500 2.25 2.16 2.35 2.35 c) c 3 16-22 A 05 0 !_t._ L2 i .!z. Q.__ li/i x 1114 x 2 840004345 - D1446 500 2.10 2.10 1I iT7 2 /2 2 x x 840004576 TT 500 1.49 1.88 1.60 5 "J" _________ _•_•,j_ I ) .15 f r5 Jj ....L........... ....LL i_ 840004352 Y-531 500 1.41 Tt TT I3 2x2x¼ .i L1½x1x½ 840004584 1T 500 1.60 1.97 1.68 11 L 0 x 1 a ¼ 840004360 01532 500 1.52 1.37 T7 11W 2 a 2 xl 840004592 D1663 500 r14 1.13 2.02 1.85 ____JL J. iL a 101 840004376 01533 500 1.65 1.50 111 1117 2!L114 2e2 x P/i 840004600 1T1 500 1.90 2.10 2.04 1 A.. - 1½ xl xl ½ 440004386 01534 500 1.82 1.61 1.88 '1I4 2 x 2 x ½ 840004618 01665 500 2.02 2.02 2.16 2.18 42L, 'C__'s j,.._ 412 Z_ ..- .....i 1½ a 1 a 1½ 840004394 01535 500 1.94 11 11T TT 2 a 2 a . 01667 500 2.60 2.60 2.39 3.61 - ;'s 9 11P Js 1.' £r. 50__I__ e ....sa41 ......2.. ..1_.2.. .............2. .......!.. 1½ x1114 a ½ 840004402 01541 500 1.41 lIT 1.66 T' 2½x 2x ¼ . 11Th 500 1.14 1.60 2.32 2.28 4-0,13".1 _C __ - ,z za t -fl-- 1½x1'/,x¼ 840004410 01542 3ö 1.52 115 1.75 1 1.15 ________ _______ •Q_iR1 _jj _________________________________ J;i A-N-01L.Starl- Fire Pcodur.ts 0iv1aisn ul .Anvil' tnlu;national Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME B 16.3 Class 150. UL Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME 81.20.1. APPROVED Ductile iron per ASTM A536 Class 65-45-1 2. For Listing /Approval NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile details contact your AnviIStar 4 Representative. iron Fittings should be tightened three turns beyond hand tight, but no more than Four turns. Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: . SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, .g REV. 03.03.060014 go to www.anvilstar.com or contact your local AnviiStar represntative A -riv- 11, L Btr" Fire Products Di in ni Anvil' !eterimuurgl ENVIL Ductile Iron Submittal Sheet T41 -•" Nominal Anvil Item Universal Max. Working Dimensions Approx. Size Number Number Pressure A WI. Each 1 x•½ 840010155 D8C031 500 1.69 0.39 3450 482 0.18 1 x 840010163 08(032 500 1.69 0.53 3458 12.92 8.24 Ductile iron threaded fittings are UL & UIC Listed & Dimensions conform to ASME B1 6.3 Class 150. ® Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B1.20-1. Ductile iron per ASTM A536 Class 6545i 2. APPROVED ForListing/Approva NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile details contact your AnviIStarTM Representative. iron fittings should be tightened three turns beyond hand tight, but no more than four turns. SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, xcv. 03.03.06.0017 • go to www.anvilstar.com or contact your local AnvilStar representative AtLStr Fire Fdiicts Di,-Aeon at Asi'Al' lflternatjesal Submittal Sheet Ductile Iron tiominal Anvil Item Universal Max. Working Dimensions Approx. Sire tiumber (lumber Pressure _________ WI. Each lit (flint) PSI (kPa) In (mat) In (mm) Lb.s (kg) 1x½ 840001036 0890031 500 1.26 1.36 0.44 :1St 15 34C 53.30 36.56 020 1x164 840001044 0890032 500 1.37 1.45 0.52 3.153 34.i 55.83 01 4 11Ax½ 840001051 D890041 500 1.34 1.53 0.64 3450 5403 11 1'/ix.'u 840001069 0890042 500 1.45 1.62 0.72 4S0 3353 Li4 333 1x1 840001017 0890043 500 1.58 1.61 0.75 .0 X 75 .5650 ;013. 1½x1 840001085 D890053 500 1.65 . 1.80 0.92 40x25 . 3650 4191 45.13 062 1'hx .840001093 0890054 500 1.82 1.88 1.08 40 X V, 3450 46.2.7 43.15 0.69 2x½ - 840001101 0890061 500 1.49 1.88 . 1.08 5815 .1.611 3U4 6?]!i 8.10 2x~A 840001119 0890062 500 1.60 1.91 1.24 50 20 6064 5003 1156 2x1 840001127 D890063 500 1.73 2.02 1.40 3450 6:194 SUC 0.61 2x1',4 840001135 0090064 500 1.90 2.10 1.52 53.34 0.10 2x1½ 840001143 0890065 500 1 2.02 2.16 1.65 Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME B16.3 Class 150. UL -Ougq Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B 1.20. 1. Ductile iron per ASTM A536 Class 65.45.12. APPROVED For Listing /Approval details contact your NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile AnvilstarrnP.epresontative. iron Fittings should be tightened three turns beyond hand tight, but no more than Four turns. 31 Project: Date: Phone: Architect.! Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast & Ductile Iron Fittings For the latest IJLIULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.060012 go to www.anvilstar.com or contact your local AnvilStar representative . ' J P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thi-u 2 inch .4FCON#300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - C 203-EX 2551 Listed only for use with AFON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel. CPVC. or copper pipe. Snap into locking position on swivel nut of AFCON 4300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler ssten1 pipe: 'erily that all assembly colnpoiients are. cleaned of any surface oil. FEATURES - °' Listed only for use with .4FCON #300 Ring Hanger. ORDERING - Part # and size. Specific APCOfs products are eselusinelv designed to be compatible ONLY with other AFCOtVproducts including parts and ftstetiers. resulting in a listed sway bract, retraitInr or hanger assembly. lIe advised the following warrant) restriction will apply. DlSCL% IMII( . ,IPCI)N will NOT warrant against sire lilurc of its products wlsun uscd tit contbinautort with ctbce products, parts or systems stot mrnufaclurcd or sold by AttOV. YCON shall NOT be liable under my circuatsaraces wltniaor for attn direct at indirect. ntcidetttal or consequential dnfltndcs Ol any kind. titcltidtti bet not limited in loss uI business or pruflt, when nati.AFCOM products Im a been. or are used. IMPERIAL MAX REC. LOAD LBS. METRIC PIPE I ROD PIPE RO2 1/2 318 400 I to 3/4 318 400 20f 10 1 318 400 25 l.....J!... 1114 318 400 32 10 1 1/2 318 400 40 In 2 318 400 50 ii) 2112 318 600 65 itl 3 3/8 600 so to 31/2 318 600 - 10 4 318 1000 100 in 5 1/2 1 125 12 6 112 250 ISO 12 8 112 1250 200 12 Order Port 1300m Note: 1/2 Ring Hanger nOL <FM' approved A Inch pipe 5 thru 8 Inch pipe I 1 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER Ll 314 thru 4 Inch pipe LISTED FOR STEELICPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mit. Galvanized to G-90 spec. LISTING/APPROVAL - c®IJs 203-EX 2551 Approval guide - Pipe Hangers OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-17l (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel.. CPVC or copper piping. INSTALLATION.- Per NFPA 13. 13R. 130 and CPVC manufacturers instructions. SPECt,LNOTI: When installing an CPVC sprinkler system :cl.ify that all assembly components are cleaned of any surface oil. FEATURES - Sired and listed exclusively for use with 9310 Surge Restrainer Band edge is offset for EASY pipe insertion. Custom fit swivel nut for better retention in ring body. Full length knurl on swivel nut for better Qrip. ORDERING - Part #. pipe size. 5/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org ALL THREADED ROD 10' -0' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650F 75OF .1/4 3/8 240 610 215 540 1/2 1130 ioib 5/6 1810 1610 3/4 2710 2420 718 3770 . 3360 4960 4420 11/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750F SIZE - 1/4 thru I 1/2 inch rod in .1.0'- 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. ORDERING - Part l!. rod. diameter and finish. 3/00