Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; 120; FA110013; Permit10/21/2020 FAII00I3 Permit Data City of Carlsbad Fire Alarm Permit Permit No:. FAII00I3 1905 CALLE Job Address: . Status: ISSUED BARCELONA . Permit Type: FALARM Applied 2/25/2011. • Parcel No: 2550120400 Approved: 2/25/2011 Lot #: 0 Reference No.: • . . Issued: 2/25/2011 PC #: • Inspector: Project Title: URBAN OUTFITTERS T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: NUTECH FIRE ALARM & SECURITY STE. 101 9970 BELL RANCH DR.:. SANTA FE SPRINGS, CA 562-946-3473 . Owner: FOURTH QUARTER PROPERTIES XXX L L C C/O THOMAS TROPEA 45 ANSLEY DR • . NEWNANGA Fees ($) Add'.l Fees ($) Total ($) • Balance ($) 125 - 0 . 125 0 I/I "ftowft~ F I R M A L A R ?sp A 71 D S IM C Li R I T 9970 BELL RANCH RD-STE 101 SANTA FE SPRINGS, CA 90670 PH# 562.946.FIRE(3473), FAX# 562.946.3474 URBAN OUTFITTERS THE FORUM AT CARLSBAD Product Submittal Model # Descriøtion 5700 ADDRESSABLE FIRE ALARM CONTROL PANEL 7170-0559:0144 SD505-APS ADDRESSABLE PHOTOELECTRIC SMOKE DET. 7272-0559:0129 S0505-4AB BASE SMOKE DET. 7272-0559:0129 50505-DUCTR ADDRESSABLE DUCT SMOKE DETECTOR 3240-0559:0163 SD500-ARM ADDRESSABLE RELAY MODULE 7300-0559:0132 SD500-MIM ADDRESSABLE INPUT MODULES 7300-0559: 0132 HSC HORN-STROBE CEILING MULTI-CANDELA-(EXCEDER) 7125-0785:0168 STC STROBE CEILING MULTI-CANDELA-(EXCEDER) 7125-0785:0168 c'; (t bb 13 lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. lntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800446-6444, or in Minnesota, call 763-493-6435. Description 5700 performs drift compensation and calibration checks on each of the sensors in the system. The basic lntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Up to 50 addressable points Up to 125 zones and 125 output groups Uses standard wire—no shielded or twisted pair required Built-in digital communicator. Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Distributed, intelligent power Drift compensation 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Notification circuits configurable as I Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5A at 27.4 VDC Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A © 27.4 VDC, power-limited Standby Current: 200 mA Alarm Current: 325 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Mechanical Specifications Dimensions: 12.75' W x 15.2' H x 3.4" D (32.39 W x 38.42 H x 8.57 0 cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Model 5700 Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ3IX (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, watertlow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:144; MEA 429-92-E Vol. XVI. DSILENT KNIGHT V by Honeywell SLC Detectors SD505-APS Addressable photoelectric smoke detector. SD505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F-150°F (0°C-37°C). S0505-SAB Six inch base for use with detector heads SD505-APS, SD505-AIS and SD505-AHS. SD505-4AB Four inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS. SD505-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61B Short circuit isolator base for SD505-AHS, SD505-APS, and SD505-AIS detectors. S0505-6RB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-ADH Duct housing that detects smoke in HVAC ducts. S0505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and SD505-AIS sensors. Compatible with S0505-DTS remote test switch. SD500-PSISD500-PSDA SD500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules Model SD500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500-MIM Mini dry contact input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SD500-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500-SDM Two-wire detector input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500-LEDs can be used per system. S-BUS Accessories 5860!R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LEDIIO Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 km( Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"W x 10"H x 6"D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-ADHR. J-h - 5Di.JI 6D $Dsfl 1b *OOO* L 5700 5496 D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350392 Rev. D, 04/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 553694927. Copyright© 2006 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0144 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 'lFP-50 and '5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: IFP-50, 5700 Control Units 7628 EOL Resistor 5860/5860R/RA-1000 Annunciator 5897 Power Supply 5496 'Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-LIM Line Isolation Module 5D505-61 B Isolation Base RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed sj the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational i' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0144 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model S0505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog I Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 40 Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: 5D505-6AB (Sold Separately) (6" Base) S0505-4AB (4" Base) DSILENT KNIGHT by Honeywell Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 3-15I16 an D) ( qr ~\, % — 0 ii — Height =2 inches, Including base rD a,ff Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) D SILENT This document is not intended to be used for installation purposes. We try to TTGT..'_'- keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350225 Rev C,. 05/05 Copyright © 2005 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0129 Page 1 of I CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: SILENT KNIGHT SECURITV7550 Meridian Circle, Maple Grove, MN 553694927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model S0505-APS analog addressable photoelectric type smoke detector with model 5D505-4AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:0149 Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division SD505-DUCTR Model SD505-DUCTR Duct Detector Housing with SD505-APS Analog Photoelectric Smoke Sensor and Relays and Model SD505-DTS-K Remote Test Switch Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector Analog Duct Smoke Detector with Relay Module and Remote Test Switch The SD505-DUCTR Addressable duct smoke detector provides early detection of smoke and products of combustion present in air moving through an HVAC duct to prevent re-circulation of smoke into the air handling system. The SD505-DUCTR is a heavy duty metal housing with a pre-installed SD505-APS Analog Photo Electric Smoke Sensor and relay module. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight FACP. The built-in relay module, in turn, turns off fans, blowers, and other devices. The SD505-DTS-K is a remote test switch that is used with the SD505-DUCTR so you can remote test the Duct Detector. It also provides LED indication of the status of the SD505-DUCTR. The 5D505-DTS-K uses the same key as the control panel. Features Two-wire connection to SLC Detects and limits the spread of smoke Rugged steel backbox with clear plastic cover LED alarm indication and communication on sensor head No screens or filters to clean SD505-APS Photoelectric Smoke Detector pre- installed. 3 standard tube lengths Large terminal connection screws UL Listed CSFM MEA 429-92-e Vol XI DSILENT 7550 Meridian Circle, Suite 100 KNIGHT Maple Grove, MN 55369 $ 763-493-6400 or 800-328-0103 by Honeywell Fax: 763-493-6475 www.silentknight.com SD505-DTS-K Specifications Rating SD505-DUCTR Alarm Relay Contact Rating 1OA @ 24VDC IOA@ II5VAC IOA @ 24OVAC Trouble Relay Contact Rating 2.5A @30VDC Operating Voltage 24VDC Aux. Power Input Current 20mA Standby 62mA Alarm SLC Input Current 0.5mA Maximum SLS Resistance SO Ohms Operating Temperature 32°F - 100°F Humidity 10% -85% RH Non-Condensing Air Velocity Rating 300-4000 ft./min Dimensions 91/8'Lx71/4"Wx21/4"H Maximum Net Weight 3lbs Sampling Tubes 2.5ft., sfi, or lOft Style 6) Wiring 3ty1e 4) Wiring SD505-DUCTR Duct Detector Housing with Relay Module and S0505-DTS-K Remote Test Switch Engineering Specifications The Air Duct smoke detector with relay module remote test switch shall be Silent Knight module SD505-DUCTR and S0505-DTS-K. The housing shall contain a Analog Photoelectric Smoke Sensor, Silent Knight model SD505-APS. Alarm Relay rated at 1 O @ 120/240 VAC and 24 VDC to control HVAC power. Module shall have separate LEDs that indicate normal or alarm condition. Module shall have a momentary key switch for testing of the duct detector. SD505-DUCTR and SD505-DTK-K Wiring Connection D SILENT This document is not intended to be used for installation purposes. We try to keep KNIGHT our product information up-to-date and accurate. We cannot cover all specific application or anticipate all requirements. All specifications are subject to change by Honeywell without notice. For more information contact Silent Knight 7550 Meridian Circle, Suite 100, Maple Grove, MN 55369-4927 Phone: (763)-493-6400 or (800) 328-0103, fax (763) 493-6475 www.silentknight.com Made in America Form# 350005 Rev A © 2009 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 3240-0559:0163 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models SD505-DUCT and SD505-DUCTR duct smoke detector units, SD505-DTS-K remote test switch. Each unit consists of a smoke detector head, plastic enclosure, plastic cover, relays, electrical components, and sampling and exhaust tubes. The smoke detector heads are not suitable for use as open area detection. Refer to listee's data sheet for additional, detailed product description and operational considerations. RATING: 120 VAC, 230 VAC, 24 VAC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as duct smoke detector units for use with separately listed compatible fire alarm control units to detect an abnormal amount of smoke density in the return air ducts of air conditioning and ventilating system. The air velocity in the duct shall be between 300-4000 fpm. NOTE: For duct application only. Not suitable for open area protection. XLF: 3240-0410:0155 07-15-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed s\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division SD500-AIM & SD-500-MIM Addressable Input Modules I ntell i Knight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 500 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" 0 (12.4 W x 12.4 H x 25 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 0 cm) Weight: 1.6 oz (45.4 g) I 01—el SD500-AIM 1*0 SD500-MIM Approvals NFPA71 &NFPA72 UL 864 CSFM 7300-0559:132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL Support for Class A (Style 6 & Style Environmental 7) or Class B (Style 4) wiring Operating Temperature: Attractive ivory cover plate with the 32°F - 120°F (0°C - 49°C) SD500-AIM Small and lightweight size allows for Humidity: 10% - 93% non-condensing flexible mounting options with the SD500-MIM DIP switch programmable for fast installation SILENT KNIGHT by HoneyiieII SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate To contact bctntaied 4,71, LOL Ut MWMngtsSUperviscd P!WerUflted Compatibility Ordering Information lntelliKnight 5820 FACP SD500-AIM Input Module lntelliKnight 5808 FACP Addressable input module with ivory lntelliKnight 5700 FACP cover plate. SD500-MIM Mini Input Module Addressable mini input module. D 'SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev.C, 05/06 subject to change without notice. For more information, contact Silent Knight by HoñeyWéll 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927. Copyright© 2006 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. Model SD500-ARM Addressable Relay Module Place relay applications anywhere on the IntelliKnight loop with the SDSOO-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SDSOO-ARM Features Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A @ 30VDCor.6A@ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Two sets of Form C contacts. Contacts are rated at 2A @ 30 VDCor.6A@ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved D SILENT KNIGHT a M cm1oN La Model 31131500-ARM Specifications Contact Rating: Form C 2A@ 3OVDC .6A@ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA Ambient 32°F to 120°F Temperature (0°C to 490c) Mounting 4-square electrical box Model SD500-ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VOC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW CAUTION REMOVE POWER PRIOR TO SERVICING [ 4-7/8" 1" D Model SD500-ARM Addressable Relay Module Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350218, Rev. 11/01 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright © 2001 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0132 Page 1 of I CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model SD500-ARM Relay Module and SDSOO-AIM, SD500-MIM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SDSOO-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-I0Im This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division - Save up to 48% in current draw* - Up to 9 models now in I appliance - Save up to 14% cost of installation** Sleek Modern Aesthetics IWO Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 8 Candela Settings WO Wail - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 6 J Universal Mounting Base Ceiling and wail Mounts to 5 Backbox Types COOPER Notification E,XtrE'D'9M- I Finally, Design and Safety Meet... Ceiling Wall Description: The Wheelock® Excedefl Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12124 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing fora greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models *** Patented ** Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. IA WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32F to 120F (OC to 49CC) and maximum humidity of 93% (±2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low ACurrent ii IitW = FewerPower 1Supplies 'Strobe Ratings per UL Standard 1971 UI• Max Current' 24 VDC /24FWR 12 VDC 7--777 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 -0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC UL Max Current' at =___ 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 1 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0197 0.242 0.282 0.125 ••••• z • • • u 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163i - 0.186 0.230 0.272 0.122 ••••• Max Current' =••u•• 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 10.120 Horn Ratings per UL 464 Model Regulated Voltage VDC 99 dBRange HN 16-33.0 0.064 16-33.0 a 0.084 8.0-17.5 0.047 8.0-17.5 0.047 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync wISM, Model Strobe DSM or 12124 VDC* Mounting Candela PS & Options . a.- HSR 15/1575/30/75/95/110/135/185 X X UMB** • HSW 15/1575I30/75I95111011351185 X X UMB** S HSRC 15/30/60175/95/115/150/177 X X . UMB** S HSWC 15/30/60/75195/115/150/177 X X UMB** • a.- STR 15/1575/30175/95/110/135/185 X X UMB • S1W 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75/95/115/150/177 X X UMB** HNR • X X UMB HNW • X X UMB** ,HNRC X X UMB** HNWC X X UMB** *12 VDC models feature 15 & 15/75 settings **UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. 4 Wheelock" (MCJ Architects and Engineers Specifications The notification appliances shall be Wheelocke ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VOC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patentedUniversaI Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" 0. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC IEM. -_-I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 11109 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Raylon Smith (732) 962-7832 Fax (732) 962-7856 Email: raylon.smith@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, MS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75,30,75,95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95,115,150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 3 SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an lntelliKflight fire alarm control panel to every area within your facility. Now you can operate and program your InteiliKnight system from up to eight locations throughput your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. 11 In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to eight 5860s per FACP Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on1 SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Standby Current: 20 mA max Alarm Current: 25 mA ..." Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color • 5860R: Red 5860: Gray vr I tt Ctt tI — 5860 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Compatibility The 5860 is compatible is the following FACP's: lntelliKnight 5820XL FACP lntelliKnight 5808 FACP IntelIiKnight 5700 FACP Approvals/Listings NFPA 72; UL Listed; CSFM 7170-0559:135; MEA 429-92-E Vol. IX; FM Approved 5860 Remote Annunciator Engineering Specifications The main control must-have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of-the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP. SBUS 5860 I ail iu45I .1 5860 Up to Eight 5880s Per. System 5860 Compatible InteliiKnight FACP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev E subject to change without notice. For more information, contact Silent © 2010 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com