HomeMy WebLinkAbout595 GRAND AV; ; FS150018; PermitFees ($) Add'I Fees ($) Total ($) Balance ($) 224 • 0 • 224 •. 0 •• .. • -• . •••• t . S • - .•' ••• • ..• ,•• (4 - - S • 1/1 9/16/2020 FS150018 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS150018 Job Address: 595 GRAND AV Status: APPROVED Permit Type: FIXSYS Applied 10/20/2015 Parcel No: Approved: 10/21/2015 Lot #: '0 Reference No.: • Issued: 10/21/2015 PC #: • Inspector: PrOject Title: CICCIOTTIS RESTAURANT HOOD& DUCT,FIRE SUPPRESSION SYSTEM-PRO TEX II Applicant: k Owner: CALIFORNIA STATE FIRE PROTECTION 36140 JANA LANE WILDOMAR CA 800 282 9229 • • • I 4P t 1 i) Chapter 3 - System Design The nozzle(s) must be installed on the centerline of the duct, with the tip located 0 to 6 in. into the opening, and aimed directly into the duct opening. See Figure 3-1. 0.6 IN. INTO DUCT 20 NOZZLE L ____10 _ Figure 34 ONE-FLOW DUCT PROTECTION WITH 1L NOZZLE (P/N NLiL) The 1L Nozzle (P/N NL1L) is capable of protecting square or rectangular ducts with a maximun perimiter of 50 in. (127 cm.), with the longest side being a maximum of 17 in. (43.2 cm). It can also protect a round duct with a maximum diameter of 16 in. (40.6 cm.) See figures 3-2 & 3-3. FS150018 CHAPTER III ) SYSTEM DESIGN GENERAL a maximum of 34 in. It can also protect a round duct #itha This section will cover the proper design of the Prot"Series II maximum diameter of 31-7/8 in.A. Restaurant Fire Suppression System. It is divided into four (4) sections: Two (2)NL2D duct nozzles can protect a square or rectangular duct with a maximum of 150 in. perimeter, with tle longest side Cylinder Sizing being a maximum of 51 in. They can also protect a round duct with a maximum diameter of 47-1/2 in. Nozzle Coverage and Placement When two (2) NL2D duct nozzles are used to protect a single Piping Limitations duct, the cross sectional area of the duct must be divided into two equal symmetrical areas. The nozzle must then be installed on the Detector Requirements centerline of the area it protects and aimed directly into the duct opening. Each of these sections must be completly understood before attempting any installation. 1. SYSTEM CYLINDER SIZING " Each of the nozzles in the section, "Nozzle Coverage and Placement" has its own flow point value. Each of the four different agent tanks can support a maximum number of flowpoints, based on the volume of the pipe used. Select the system tank(s) by calculating the total number of flow points ssociated with the appliances(s), plenum, and ducts, plus the total piping volume. CAUTION! Do not exceed the maximum number of flowpoints as shown on the Tank Chart, page 48. If the number of flow points or the pipe volume required exceeds the amounts shown, additional tank(s) or changes in piping design are required. 2. NOZZLE COVERAGE AND PLACEMENT This section will provide guidelines for determining nozzle type, positioning, and quantity for duct, plenum, and appliance protectiol.. A. DUCT PROTECTION It is not required that the fan be shut down or the exhaust duct be dampered for the system to operate properly. Each nozzle is approved to protect exhaust ducts of unlimited length. Duct protection requires that a nozzle be positioned to discharge p, into the duct. Either a P/N NL1L or a P/N NL2D can be .used. The NL2D duct nozzle is a two (2) flow nozzle A single NL2D nozzle is capable of protecting square or rectangular duct with a maximum of 100 in. perimeter, with the longest side being UL EX4521 December 12, 2006 11 - - - - Page rev. C Part # 10053 Fig 3-6 ELECTROSTATIC PRECIPITATOR Ducts utilizing electrostatic precipitators must be protected above and below the unit. Standard duct nozzles are used in this application. See Figure 3-7. Figure 3-7 Chapter 3 - System Design 8" 17" Figure 3-2: Maximum rectangular duct perimeter of 50" Figure 3-3: Maximum round duct diameter of 16" TRANSITION DUCTS The protection of non-standard ducts-should be reviewed by the authority having jurisdiction. Protex Series II recommends that transition ducts be protected as follows: / PEI ME Figure 3-5 C. MULTIPLE RISERS In cases of multiple risers, each riser is protected as an individual duct. See Figure 3-6. DUCT PLENUM PERIMETER - 1/2WRf INTO MEASUREMENT1// + TRANSITION Figure 3-4 TRANSITION DUCTS - LARGER TO SMALLER In cases where the duct/plenum interface opening is larger than the final exhaust duct, measure the perimeter/diameter of the duct halfway between the largest and smallest section (or the average perimeter/diameter). The nozzle is to be located within 0-6 in. of the duct/plenum interface (not at the point where the measurement was taken), centered under the final exhaust duct opening. See Figure 3-4. TRANSITION DUCTS - SMALLER TO LARGER In cases where ihe duct/plenum interface opening is smaller than the final exhaust duct, measure the perimeter/diameter of the final exhaust duct. The nozzle(s) is to be located within 0-6 in. of the duct/plenum interface, centered in the opening. See Figure 3-5. t Page rev. C UL EX4521 December 12, 2006 12 Part # 10053 V-BANK SINGLE BANK Chapter 3 - System design B. PLENUM PROTECTION The NL1H nozzle is a one (1) flow nozzle used for plenum protection. A single NL1H nozzle can protect a plenum (with single or V-bank filters) 10 ft. long by 4 ft. wide. Dividing the length into sections equal to or less than 10 ft. in length and positioning a nozzle at the start of each section can be done to protect longer plenums. On V-bank plenums, the nozzle(s) must be located at the center of the V-bank width, 1/3 of the vertical height of the filters. On single filter bank plenums, the nozzle must be located 2 in. from the back edge of the filter, 1/3 down from the vertical height. For either application, the nozzle must be located within 6 in. of the end of the plenum (or module) and aimed directly down the length of the plenum. See Fig. 3-8. Figure 3-8. Page rev. C UL EX4521 December 12, 2006 13 Part # 10053 Chapter 3 - System Design a NOTES: U Page rev. C UL EX4521 December 12, 2006 14 Part # 10053 I Chapter 3 - System Design APPLIANCE' PROTECTION to or smaller than single nozzle coverage. Exception: Fryers must Note: When protecting appliances which are larger than single not exceed a maximum of 864 sq. in. For modularizing fryers, nozzle coverage, multiple nozzles can be used. refer to "Protecting Large Fryers by Dividing Their Area Into Modules," page 22. Larger appliances can be divided into several modules, each equal Design Index Chart and Nozzle Coverage Summary Sheet Min Max Max Max Max Nozzle Nozzle Nozzle Flow Depth Length Area Height Height Appliance Mount Figure Type Points Max Width (in) (in) (in) 60 (in) (in) Deep Fat Fryer - Vat H 3-3 NL2H 2 19-1/2 19 24 48 Deep Fat Fryer - Vat L 3-4 NL2L 2 19-1/2 19 13 24 Deep Fat Fryer w/ drip board H 3-5 NL2H 2 Deep Vat 27-3/4 324 24 48 (Condition 1) Overall Cooking Area 18 500 24 48 Deep Fat Fryer w/ drip board H 3-5 NL2H 2 Deep Vat 19-1/2 371 24 48 (Condition 2) Overall Cooking Area 25-3/8 495 24 48 Deep Fat Fryer w/ drip board L 3-5 NL2L 2 Deep Vat 18 324 13 24 (Condition 1) Overall Cooking Area 27-3/4 500 13 24 Deep Fat Fryer wl drip board L 3-5 NL2L 2 Deep Vat 19-1/2 371 13 24 (Condition 2) Overall Cooking Area 25-3/8 495 13 24 Tilt Skillet/Braising Pan H 3-7 NL2H 2 27-3/4 500 24 48 Tilt Skillet/Braising Pan L 3-8 NL2L 2 I 27-3/4 500 13 24 Four Burner Range 3-9 NL2L 2 28 28 34 48 Two Burner Range H 3-10 NL1H 1 12 28 40 50 Two Burner Range L 3-11 NL1L 1 12 28 13 24 Two Burner Range H 3-11b NL2L 2 12 28 24 35 Small Wok' H 3-12 NL1H 1 24" dia. 6 24 48 Small Wok L 3-13 NL1L 1 24' dia. 6 13 24 Lai'ge Wok H 3-14 NL2H 2 30" dia. 8 24 48 Large Wok L 3-15 NL2L 2 30' dia. 8 13 24 Small Griddle H 3-16 NL1H 1 36 1080 24 48 Small Griddle L 3-17 NL1L 1 36 1080 10 24 Large Griddle H 3-18 NL2H 2 48 1440 24 48 Large Griddle L 3-19 NL2L 2 48 1440 10 24 Gas Radiant Char-Broiler H 3-20 NL1H 1 26 624 24 48 Gas Radiant Char-Broiler L 3-21 NL1L 1 26 624 13 24 Large Gas Radiant Char-Broiler H 3-22 NL2H 2 36 864 36 48 Large Gas Radiant Char-Broiler L 3-23 NL2L 2 36 864 13 36 Lava Rock Char-Broiler H 3-24 NL2L 2 26 624 24 35 Lava Rock Char-Broiler L 3-25 NL2L 2 26 624 15 24 Natural Charcoal Char-Broiler H 3-26 NL1H 1 24 480 24 35 (max. fuel depth 6') Natural Charcoal Char-Broiler L 3-27 NL1L 1 24 480 15 24 Mesquite Char-Broiler H 3-28 NL1H 1 24 480 24 35 (max. fuel depth 6") Mesquite Char-Broiler L 3-29 NL1L 1 24 480 15 24 Upright/Salamander Broiler 3-30 NL1L 1 36 28 Front Edge above the grate Chain Broiler (Internal Chamber) 3-31 NL1L 1 27 38 Front Edge 1-3" above the chain Plenum Single Bank / V Bank H NL1H 1 48 120 0"-6" from end of plenum .:Duct Perim. Diameter (in) Rectangular/Circular Duct NL2D 2 34 no limit 100 31-7/8 Rectangular/Circular Duct NL1L 1 17 50 16 Page rev. C UL EX4521 December 12, 2006 15 Part # 10053 Chapter 3 - System Design Fryers Without Drip Board (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 19 inches x 19-1/2 inches (no drip board) Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the center of the cooking surface. Graphic Representation See figure 3-3 Nozzle must be located anywhere within the shaded area and aimed at the center of the cooking surface. Figure 3-3 Page rev. C UL EX4521 December 12, 2006 16 Part # 10053 Chapter 3 - System design Fryers Without Drip Board (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 19 inches x 19-1/2 inches (no drip board) Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 13 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the cooking surface. Graphic Representation See figure 3-4 Nozzle must be located anywhere on the perimeter of the cooking surface, Figure 3-4 Page rev. C UL EX4521 December 12, 2006 17 Part # 10053 Chapter 3 - System Design Fryers with Drip Board (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection Condition 1 Deep Vat Cooking Area 324 square inches with a maximum longest side dimension of 18 inches. (excludes drip board) Overall Cooking Area 500 square inches with a maximum longest side dimension of 27-3/4 inches. (includes drip board) Condition 2 Deep Vat Cooking Area 371 square inches with a maximum longest side dimension of 19-1/2 inches. (excludes drip board) Overall Cooking Area 495 square inches with a maximum longest side dimension of 25-3/8 inches. (includes drip board) Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the center of the cooking surface. Graphic Representation See Figure 3-5 Nozzle must be located anywhere within the shaded area and aimed at the center of the cooking surface. OVERALL OVERALL COOKING AREA COOKING AREA LONGEST SIDE 500 SQUARE LONGEST SIDE 495 SQUARE DIME :;;,//IN =iM DIME 25-3/8" MAXIMUM NSION,,-- COOKING COOKING 27-3/4" 324 SQUAR INCHES MAXIMUM DEEP VAT AREA DRIPBOARD 371 SQUARF.-, INCHES MAXIMUM VAT I I ,AREA DEEP 18" I I 19W' LONGEST DRIPBOARD LONGEST SIDE SIDE DIMENSION DIMENSION Condition 1 Condition 2 Figure 3-5 Page rev. C UL EX4521 December 12,'2006 • 18 Part # 10053 .T t 371 SQ INCHES MAXIMUM DEEP VAT AREA DRIPBOARD SIDE DIMENSION (DEEP VAT) Condition 1 Figure 3-6 324 SQUARJ INCHES MAXIMUM DEEP VAT AREA DRIPBOARD J11 LONGEST SIDE DIMENSION (DEEP VAT) Condition 2 4 Chapter 3 - System design Fryers with Drip Board (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection Condition 1 Deep Vat Cooking Area 324 square inches with a maximum longest side dimension of 18 inches. (excludes drip board) Overall Cooking Area 500 square inches with a maximum longest side dimension of 27-3/4 inches. (includes drip board) Condition 2 Deep Vat Cooking Area 371 square inches with a maximum longest side dimension of 19-1/2 inches. (excludes drip board) Overall Cooking Area 495 square inches with a maximum longest side dimension of 25-3/8 inches. (includes drip board) Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 13 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the cooking surface. Graphic Representation See figure 3-6 Nozzle must be located anywhere on the perimeter of the cooking surface, and aimed at the center ofthe cooking surface. OVERALL . OVERALL COOKING AREA : COOKINGAREA _. LONGEST SIDE [ 500 SQUARE LONGEST SIDE 495 SQUARE DIMENSION INCHES DIMENSION INCHES 27-3/*' MAXIMUM 2S-3/8" MAXIMUM COOKING COOKING AREA AREA >4: 1 21 S Page rev. C UL EX4521 December 12, 2006 19 • Part # 10053 Chapter 3 - System Design Note Tilt skillets or braising pans generally use a hinged cover. Nozzle(s) are to be placed at thefront edge of the appliance cooking area to minimize the potentialfor the tilt skillet or braising pan cover to interfere with the nozzle discharge. See Note, below. I Tilt Skillet/Braising Pan (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (one) Maximum Area of Protection 500 square inches with a maximum longest side dimension of 27A inches Nozzle Location Positioned near the front edge of the pan. The nozzle(s) must be completely clear of the pan cover with an unobstructed view to the back of the pan. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the front to back centerline of the pan. Graphic Representation See figure 3-7 Modularized Coverage 2. Divide the cooking area into modules, each Tilt Skillets and Braising Pans generally require of which can be protected by a single nozzle modularized coverage. Use the following steps to as specified in the determine modular coverage: design chart. 1. Measure the length and width of the Tilt 3. Ensure that no single nozzle exceeds its Skillet/Pan cooking area, limitations for area or longest side Nozzle must be located anywhere along thefront edge of the cooking area, and aimed at the center of the cooking area. Note The nozzle must be completely clear of the pan cover, with an unobstrocted flow to the back of the pan. iJ MIX I LONGEST 500 SQUARE INCHES MAXIMUM COOKING SURFACE -t Figure 3-7 Page rev. C UL EX4521 December 12, 2006 20 Part # 10053 Chapter 3 - System design Note Tilt skillets or braising pans generally use a hinged cover. Nozzle(s) are to be placed at thefront edge of the appliance cooking area to minimize the potentialfor the tilt skillet or braising pan cover to interfere with the nozzle discharge. See Note, below. Tilt Skillet/Braising Pan (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (one) Maximum Area of Protection 500 square inches with a maximum longest side dimension of 274 inches Nozzle Location Positioned near the front edge of the pan. The nozzle(s) must be completely clear of the pan cover with an unobstructed view to the back of the pan. Nozzle Height 13 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the front to back centerline of the pan. Graphic Representation See figure 3-8 Modularized Coverage 2. Divide the cooking area into modules, each Tilt Skillets and Braising Pans generally require of which can be protected by a single nozzle modularized coverage. Use the following steps to as specified in the determine modular coverage: design chart. 1. Measure the length and width of the Tilt 3. Ensure that no single nozzle exceeds its Skillet/Pan cooking area, limitations for area or longest side ) Nozzle must be located anywhere along thefront edge of the cooking area, and aimed at the center of the cooking area. Note The nozzle must be completely clear of the pan cover, with an unobstrocted flow to the back of the pan. nic LONGEST 500 SQUARE INCHES MAXIMUM COOKING SURFACE Figure 3-8 ft Page rev. C UL EX4521 December 12, 2006 21 Part # 10053 Note None of the maximum dimensions may be exceeded. If either the maximum vat or overall sizes are exceeded, the area divided into modules will need to be redefined with the possibility of an additional nozzle. .__ 26" __ 2692=832 sq. in. EXAMPLE 1 i. 832 = 2.6 nozzles 32 324 longest side: 27:V4" No drip board 2. 832 = 2.24 nozzles 371 longest side: 253/so Use #1 because it meets the longest side .4— a6" Slartfrom the back of the vat, andfigure the I .4I opposite side 12 6" 0 1.324=12.46" i260LO] Old method 26 would have 70"I 0 required S nozzles ..- .4— — Or you could just 26" ______________ I i equally divide the three 0 I t 0 0 I 1 I Sections in ro.66" each I . ,o.66' 0 - - - I I I ,o.66" 0 4— 24" —Ø 2490720 sq. in. EXAMPLE 2 A I. 720 = 2.22 nozzles T 31 , 324 longest side: 27~ (with drip Soo sq. in.) ° I 2. 720 = 1.9 nozzles 371 longest side: 25/s" (with drip 495 sq.in.) 6" Use #2 because it meets the longest side and requires fewer nozzles '4— 24' —... Slarifrom the back ofthe vat, andfigure the opposite side 0 15.45" t 371 sq. in. = 15.45 in. 24 in. longest side: 273A' 0 14-55 (with drip Soo sq.in.) 6" 24=15.45 = 370.8 sq. in. 24=14.55 = 349.2 Old method Now you need to include the drip board would have required 4 14.55" + 6" = 20.55" nozzles 24 C 20.55 = 493.2 sq. in. This does not exceed allowable sq. in. of495 0 i 0 (included in our set of numbers) 2 nozzles would cover this fryer 0 0 Chapter 3 - System Design Protecting Large Fryers by Dividing Their Area Into Modules When protecting fryers larger than those previously described, the area requiring protection can be divided into modules. In the standard fryer protection coverages, you will notice that a fryer without a drip board has a larger vat area than a fryer with a drip board. While very specific limitations apply, a larger fryer that requires modular protection could include both circumstances: a portion of the fryer with a drip board and a portion of the fryer without a drip board. Dividing the modules into either deep vat only or deep vat with drip board can maximize the modular coverage. Note: The maximum size of a fryer that can be modularized is 864 square inches (6 square feet). If the fryer has no drip board, use design charts 3-3 or 3-4 depending on whether the appliance is a high or low mount application. As the fryer does not have a drip board, the maximum overall cooking area will be the same as the maximum deep vat area. Use the following steps to determine the modular coverage; Measure the internal length and width of the deep vat. Ensure the total area to be protected does not exceed 864 square inches (6 square feet). Divide the deep vat into modules, each of which can be protected by a single nozzle as specified in the design chart. Ensure that no single nozzle exceeds its limitations for area or longest side If the fryer contains a drip board use the design charts 3-5 or 3-6 for fryers depending on whether the appliance is a high or low mount application. Use the following steps to determine the modular coverage; Measure the internal length and width of the deep vat. Measure the internal length and width of the hazard area including drip board area. Ensure the total area to be protected does not exceed 864 square inches (6 square feet). Divide the deep vat into modules, each of which can be protected by a single nozzle as specified in the design charts. If the module does not include any portion of the drip board, the maximum overall cooking area will be the same as the maximum deep vat area in the design chart. If the module includes any portion of the drip board, the maximum deep vat area and overall cooking area limitations must be adhered to. 324 sq. in.; 27W longest side; maximum area with drip-Soo sq. in. 37' sq. in.; 253/4" longest side; maximum area with drip-49$ sq. in. Page rev. C UL EX4521 December 13, 2005 22 ' Part # 10053 Chapter 3 .System Design It Two Burner Range (High Mount Nozzle) Note The range cannot be under a backsbe!f when using high-mount protection. Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 12 inches x 28 inches Nozzle Location Center of the cooking surface only. Nozzle Height 40 inches to 50 inches above the cooking surface. Nozzle Aiming Directly down only. Graphic Representation See figure 3-10 U Nozzle must be located (heighiwise) anywhere within the shaded area, I and centered above the cooking surface. - Figure 3-10 UL EX4521 December 13, 2005 23 Page rev. C Part # 10053 Chapter Four Burner Range Note The range cannot be under a backibeif when using high mount Protection. Compulsory Nozzle Flow Points Per Nozzle Number of Nozzles Required Maximum Area of Protection Nozzle Location Nozzle Height Nozzle Aiming Graphic Representation NL2L 2 (Two) 1 (One) 28 inches x 28 inches Center of the cooking surface only. 34 inches to 48 inches above the cooking surface. Directly down only. See figure 3-9 Example: A four burner range has a hazard size of 20 in. (51 cm) in length and 27 in. (69 cm) in width. Follow down the Range Length column in the Nozzle Positioning Chart until you come to 20 in. (51 cm). Continue down this column until the correct width appears in the width column. When the width of 27 in. (69 cm) is arrived at, read across to the radius column to determine the size of radius allowed, for positioning of the nozzle, from the hazard area centerline. In this example, the correct radius is 3 in. (8 cm). The nozzle can be aimed straight down anywhere within a 3 in. (8 cm) radius of the hazard area centerline. Nozzle must be located (heigbtwise) anywhere within the shaded area, and centered above the cooking surface. Figure 3-9 Page rev. C UL EX4521 December 13, 2005 24 Part # 10053 Chapter 3y Sytem Design - Nozzle Positioning Chart for Four Burner Range [RANGE ILENGTH'L' mcm)m.I RANGE WIDTH (cm) in. 7½ iRADIUS UI R. --_J . (cm)i (18) L.. - 21 RANGE LENGTH'L'. (cm). (j) RANGEWU3TH . 'W in. 26 ,, (cm) (66) - in. 3½ -RADIUS' - (cm) (8) is (46) IS (46) is (46) 19 (48) 634 (ii) 21 () 27 (69) 2% () 18 (46) 20 (ii) 63A (i6) 21 (53) 28 (71) 21/4 (6) 18 (46) 21 () 6 (15) 22 (6) is (46) 5% (i) 18 (46) 22 (6) % (i) 22 (6) 29 (48) ¼ (ii) 18 (46) 23 (8) % (ii) 22 (6) 20 (ii) 43'S (ia) 18 (46) 24 (61) 4-Y4 (12) 22 (6) 22 (ç) 4% (ii) 18 (46) 25 (64) 4% (ii) 22 (6) 22 (6) 4V4 (xo) is (46) z6 (66) 4 (jo) 22 (6) 23 (8) 33'S (io) is (46) 27 (69) 3% () 22 (6) 24 (61) 3½ () is (46) 28 (71) 3½ (8) 22 (6) 25 (64) 3½ (8) 19 (48) is (46) 63/4 (17) 22 (6) 26 (66) 2-Y4 () 19 (48) 29 (48) 6% ('6) 22 (6) 27 (69) 2% (6) 19 (48) 20 (si) 6 (is) 22 (6) 28 (p a (s) 19 (48) 22 () % (i') 23 (58) is (46) SY4 (ii) 29 (48) 22 (6) % (ii) 23 (8) 29 (48) 47'S (ia) 29 (48) 23 (58) 47'S (12) 23 (8) 20 (si) 4½ (II) ) 19 (48) 24 (61) 41h (ii) 23 (8) II (si) 4% (to) 29 (48) 25 (64) 4½ (io) 23 (8) 22 (56) 37'S (to) 19 (48) 26 (66) 3V4 () 23 (58) 23 (8) 3½ () 29 (48) 27 (69) 3¼ (8) 23 (58) 24 (61) 3½ (8) 29 (48) 28 (ix) 27'S () 23 (8) 25 (64) As () 20 (ii) is (46) 6% (16) 23 (8) 26 (66) 2½ (6) 20 (51) 19 (48) 6 (,) 23 (58) 27 (69) 2½ () 20 (ii) 20 (çi) % (i') 23 (58) 28 (71) 1% () 20 (ii) 21 (ç) ¼ (ii) 24 (6') is (46) 4~ (12) 20 (ii) 22 (6) 7'S (22) 24 (61) 29 (48) 4½ (ix) 20 (i) 23 (8) 4½ (n) 24 (61) 20 (51) 4½ (io) 20 (ix) 24 (61) 4½ (io) 24 (61) 21 (si) 3% (io) 20 (ii) 25 (64) 3-M () 24 (61) 22 (6) 3½ () 20 (ii) 26 (66) 3% (8) 24 (60 23 (8) 31A (8) 20 (51) 27 (69) 3 (7) a (61) 24 (61) 27'S () 20 (51) aS (71) 1 a% (6) 24 (61) 25 (64) 2½ (6) 21 (ç) is (46) 6 (xi) 24 (61) 26 (66) 2½ (s) 21 () 19 (48) % (id) 24 (61) 27 (69) x-Y4 () 21 (,) 20 (51) 51A (,) 24 (61) 28 (p) 1 13A (3) 21 (si) 21 () 5 (12) 25 (64) 18 (46) 43A (ii) 22 (53) 22 (6) 4% (n) 1 25 (64) 19 (48) 4½ (io) 22 (ç) 23 (ES) 4% (io) 25 (64) 20 (si) 33(4 (io) / 21 () 24 (60 33'S (to) 25 64) 22 (si) 3½ ) 22 (53) 25 (64) 1 3½ (9) 25 (64) 22 (6) 3½ (8) • RANGE'RANGE in. (cm)t - 25 (64) LENGTH -'çv WIDTH iii (cm) RADIUS in. (cm) 23 (8)23'S T () 25 (64) 24 (6')a½ (6) 25 (64) 25 (64) 1 2½ (s) 25 (64) 26 (66) 13/4 () 25 (64) 27 (69) 23/8 (3) 25 (64) 28 (p) i (a) 26 (66) is (46) 4 (zo) 26 (66) 29 (48) 3% (xo) 26 (66) 20 (ii) 3% () 26 (66) 22 (si) 3½ (8) 26 (66) 22 (6) A (si) 26 (66) 23 (8) 2½ (6) 26 (66) 24 (61) 2½ () 26 (66) 25 (64) 23/4 () 26 (66) 26 (66) 23/8 (3) 26 (66) 27 (69) , (a) 26 (66) 28 (ii) 3/4 (2) 27 (69) is (46) 3% () 27 (69) 19 (48) 3% (8) 27 (69) 20 (sO 3 (8) 27 (69) 22 () 1 a3* (7) 27 (69) 22 (6) a% (6) 27 (69) 23 (S 2½ () 27 (69) J 24 (61) i% () 27 (69) 25 (64) 23/8 (3) 27 (69) 26 (66) 1 (2) 27 (69) 27 (69) 3/4 (a) 27 (69) aS (72) 3/8 (0 28 ('x) iS (46) I 3½ (8) 28 ('i) 19 (48) As (7) 28 (p) 20 (ii) a% () 28 (ix) 21 (si) 21/4 (6) 28 (ii) 22 (56) 2 () 28 (p) 23 (58) i% () aS (72) 24 (61) 1% (3) aS (71) 25 (64) I (2) 28 (ix) 26 (66) 3/4 (a) 28 (n) 27 (69) 3/8 (1) 28 (71) 28 (ii) o (o) Page rev. C UL EX4521 December 12, 2006 25 Part # 10053 Note If the range has a backsbelf, the nozzle has to be equal to or below the height of the shelf and be within limitations of the nozzle height. Chapter 3— Sysn design Two Burner Range (Low Mount Nozzle) Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 12 inches x 28 inches Nozzle Location 22 inches from the opposite edge of the hazard area and centered right to left. Nozzle Height 13 inches to 231h inches above the cooking surface. Nozzle Aiming Aimed at a point equal to one half of the nozzle height above the appliance and along the right-left centerline. Example: If the nozzle was mounted 23 inches above the cooking surface, the aiming point would be 11112 inchesfrom the opposing edge of.the appliance on which the nozzle is located. See illustrations Example 1 and Example 2 below. Graphic Representation See figure 3-11 Nozzle must be located (beighiwise) anywhere within the shaded area, and located on the left-rgbt center line above the cooking surface. - VARIES- 22" SEE NOZZLE AIMING AND EXAMPLES 1&2 EXAMPLE 1 Nozzle is 13" above surface & aimed 6½" from opposite edge of cooking surface. (13/2=6½) EXAMPLE 2 28" Nozzle is 23" 12" above surface & aimed 11½" from rear of cooking surface. (23/2=11½) . - Figure 3-11 EX4521 December 12, 2006 Page rev. C 26 Part # 10053 L' ¼.) - Chapter 3 - System design Two Burner Range with High Proximity Backshelf Protection (Low Mount Nozzle), Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 12 inches x 28 inches Nozzle Location Over the front edge of the front burner; on the front-to-rear center line. Nozzle Height 24 inches to 35 inches above the cooking surface Nozzle Aiming Aimed at a point 10 inches forward from the back burner on the front- to-rear center line Graphic Representation See figure 3-lib n must be located over thefront edge of theftont burner, oriented with the nozzle hp aimed on thefront-to -back centerline, and aimed 10 inches forward of the back burner on the front-to-back center line. U EX4521 December 12, 2006 Figure 3-11b Page rev. C 27 Part# 10053 apter 3 - System Design Small Wok (High Mount Nozzle) Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 24 inches maximum diameter and 6 inches maximum depth. Nozzle Location Anywhere on the perimeter of the Wok. Nozzle Height 24 inches to 48 inches above the top edge of the Wok. Nozzle Aiming Directly at the center of the inside bottom of the Wok. Graphic Representation See figure 3-12 L Nozzle must be located anywhere along the perimeter of the Wok, and aimed at the center of the inside bottom of the Wok. I I I I I I I I I I I i Figure 3-12 L EX4521 December 13, 2005 Page rev. C 28 Part # 10053 Chapter 3 - System design Small Wok (Low Mount Nozzle) Compulsory Nozzle - NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) - Maximum Area of Protection . 24 inches maximum diameter and 6 inches maximum depth. Nozzle Location Anywhere on the perimeter of the Wok. Nozzle Height 13 inches to 24 inches above the top edge of the Wok. Nozzle Aiming Directly at the center of the inside bottom of the Wok. Graphic Representation See figure 3-13 Nozzle must be located anywhere along the perimeter of the Wok, - and aimed at the center of the inside bottom of the Wok. I'll IL EX4521 December 13, 2005 Figure 3-13 29 Page rev. C Part# 10053 apter 3 - System Design Large Wok (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection Greater than 24 inches diameter to 30 inches in diameter and 8 inches maximum depth. Nozzle Location Anywhere on the perimeter of the Wok. Nozzle Height 24 inches to 48 inches above the top edge of the Wok. Nozzle Aiming Directly at the center of the inside bottom of the Wok. Graphic Representation See figure 3-14 11 - Nozzle must be located anywhere along the perimeter of the Wok, and aimed at the center the inside bottom of the Wok. I U II Figure 3-14 Page rev. C JL EX4521 December 13, 2005 30 Part # 10053 Chapter 3 - System design Large Wok (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection Greater than 24 inches diameter to 30 inches in diameter and 8 inches maximum depth. Nozzle Location Anywhere on the perimeter of the Wok. Nozzle Height 13 inches to 24 inches above the top edge of the Wok. Nozzle Aiming Directly at the center of the inside bottom of the Wok. Graphic Representation See figure 3-15 - - Nozzle must be located anywhere along the perimeter of the Wok, if i -- and aimed at the center of the inside bottSf the Wok. Figure 3-15 Page rev. C JL EX4521 December 13, 2005 31 Part # 10053 apter 3 - System Design • Small Griddle (High Mount Nozzle) Compulsory Nozzle NL1H or NL2H Flow Points Per Nozzle 1 (One) NL1H or 2 (Two) NL2H Number of Nozzles Required 1 (One) NL1H or 1 (One) NL2H Maximum Area of Protection 1080 square inches with a longest side dimension of 36 inches Nozzle Location NL1H: Above any corner of the cooking surface. NL2H: 0 to 6 in. from either of the short sides of the cooking surface Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming NL1H: At a point 12 inches in and 12 inches over from the corner below the nozzle. NL2H: At the center of the cooking surface Graphic Representation See figures 3-16a &3-16b NLJH Nozzle must be located directly above any corner of the cooking surface and aimed at the intersecting point 12 inchesfrom each side of the corner below the nozzle. NL2H Nozzle must be located 0 to 6 inchesfrom either of the short sides of the cooking surface, and aimed at the center of the cookin, surface CAN BE + ANYCORNER I NOZZLE CAN BE MOUNTED AT EITHER END "r 2 1080 SQUARE INCHES MAXIMUM COOKING AREA SHORT SIDE OF COOKING SURFACE Figure 3-16a: NL1H Nozzle Figure 3-16b: NL2H Nozzle Page rev. C IL EX4521 December 13, 2005 32 Part # 10053 L EX4521 December 13, 200S 33 1080 SQUARE INCHES MAXIMUM COOKING AREA SHORT SIDE OF , COOKING SURFACE T I' NOZZLE CAN BE MOUNTED ABOVE ANYCORNER Figure 3-17b: NL2L Nozzle Page rev ç Part # 10053 Figure 3-17a: NL1L Nozzle NOZZLE CAN BE MOUNTED AT EITHER END ' J. Chapter 3 - System design Small Griddle (Low Mount Nozzle) Compulsory Nozzle NL1L or NL2L Flow Points Per Nozzle 1 (One) NL1L or 2 (Two) NL2L Number of Nozzles Required 1 (One) NL1L or 1 (One) NL2L Maximum Area of Protection 1080 square inches with a longest side dimension of 36 inches Nozzle Location NL1L: Above any corner of the cooking surface. NL2L: 0 to 6 in. from either of the short sides of the cooking surface Nozzle Height 10 inches to 24 inches above the cooking surface. Nozzle Aiming NL1L: At a point 12 inches in and 12 inches over from the corner below the nozzle. NL2L: At the center of the cooking surface Graphic Representation See figures 3-17a & 3-17b NL1L Nozzle must be located directly above any corner of the cooking surface 0 and aimed at the intersectingpoint 12 incbesfrom each side of the corner below the nozzle. NL2L Nozzle must be located 0 to 6 inthesfrom either of the short sides of the cooking surface, - - and aimed at the center of the cooking surface apter 3 - System Design Large Griddle (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 1440 square inches with a longest side dimension of 48 inches Nozzle Location Above any corner of the cooking surface. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming At a point 12 inches in and 12 inches over from the corner below the nozzle. Graphic Representation See figure 3-18 Nozzle must be located directly above any corner of the cooking surface and aimed at the intersectingpoint 12 inch from each side of the corner below the nozzle. NOZZLE CAN BE MOUNTEDABOVE ANYCORNER 12 48" LONGEST SIDE 1440 SQUARE DIMENSION INCHES MAXIMUM COOKING AREA Figure 3-18 S IL EX4521 December 12, 2006 34 Page rev. C Part # 10053 Chapter 3 - System design Large Griddle (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 1440 square inches with a longest side dimension of 48 inches Nozzle Location Above any corner of the cooking surface. Nozzle Height 10 inches to 24 inches above the cooking surface. Nozzle Aiming At a point 12 inches in and 12 inches over from the corner below the nozzle. Graphic Representation See figure 3-19 ] Nozzle must be located directly above any corner of the cooking surface and aimed at the intersectin! point 12 inches from each side of the corner below the nozzle. ZZLECANBE I MOUNTED ABOVE i ANYCORNER 2 12 48 LONGEST SIDE -. '•• 1440 SQUARE DIMENSION ••d- INCHES - . MAXIMUM COOKING AREA Figure 3-19 Page rev. C L EX4521 December 13, 2005 35 Part # 10053 • Ipter 3 - System Design Small Gas Radiant Char-Broiler (High Mount Nozzle) Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 624 square inches with a longest side dimension of 26 inches. Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the cehter of the broiler. Graphic Representation See figure 3-20 ] Nozzle must be located anywhere within the shaded area and aimed at the center of the cooking surface. Figure 3-20 Page rev. C L EX4521 December 13, 2005 36 Part # 10053 RE JM JG Chapter 3 - System design Small Gas Radiant Char-Broiler (Low Mount Nozzle) Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 624 square inches with a longest side dimension of 26 inches Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 13 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-21 11 Nozzle must be located anywhere on the perimeter of the cooking surface, and aimed at the center of the Looking suice. Figure 3-21 IL EX4521 December 13, 2005 Page rev. C 37 Part# 10053 apter 3 - System Design I-' Large Gas Radiant Char-Broiler (High Mount Nozzle) Compulsory Nozzle NL2H Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 864 square inches with a longest side dimension of 36 inches Nozzle Location Above any corner of the cooking surface. Nozzle Height 36 inches to 48 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-22 - Nozzle must be located directly above an; corner of the cooking surface, and aimed at the center of the cooking surface. - \ NOZZLE CAN BE MOUNTED ABOVE I ANYCORNER \ \ ' I SQUARE HES XIMUM OIUNG EA .1 Figure 3-22 Page rev. C IL EX4521 December 13, 2005 38 Part # 10053 Chapter 3 - System design Large Gas Radiant Char-Br9iler (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 864 square inches with a longest side dimension of 36 inches Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 13 inches to 36 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-23 D Nozzle must be located anywhere on the perimeter of the cooking surface, and aimed at the center of the cooking surface. 13" 36" 36" LONGEST SIDE DIMENSION 864 SQUARE INCHES MAXIMUM COOKING AREA Figure 3-23 L EX4521 December 13, 2005 Page rev. C 39 Part# 10053 apter 3 - System Design Lava Rock Char-Broiler (High Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 624 square inches with a longest side dimension of 26 inches Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 35 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-24 I n I Nozzle must be located anywhere within the shaded area and aimed at the center of the cooking surface. Figure 3-24 Page rev. C 'L EX4521 December 13, 2005 40 Part # 10053 Chapter 3 - System design Lava Rock Char-Broiler (Low Mount Nozzle) Compulsory Nozzle NL2L Flow Points Per Nozzle 2 (Two) Number of Nozzles Required 1 (One) Maximum Area of Protection 624 square inches with a longest side dimension of 26 inches Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 15 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-25 11 Figure 3-25 LL EX4521 December 13, 2005 41 Page rev. C Part # 10053 apter 3 - System Design Natural Charcoal Char-Broiler (High Mount Nozzle) Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 480 square inches with a longest side dimension of 24 inches Fuel Depth (Charcoal) Must not exceed 6 inches Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 35 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-26 n Nozzle must be located anywhere within the shaded area and aimed at the center of the cooking surface. 480 SQUARE INCHES MAXIMUM COOKING AREA 2r. MAXIMUM DEPTH OF FUEL (CHARCOAL) MUST NOT EXCEED 6 INCHES LONGEST SIDE DIMENSION Figure 3-26 IL EX4521 December 13, 2005 Page rev. C 42 Part # 10053 S Page rev. C Part # 10053 II Chapter 3 - System design Natural Charcoal Char-Broiler (Low Mount Nozzle) Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 480 square inches with a longest side dimension of 24 inches Fuel Depth (Charcoal) Must not exceed 6 inches Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 15 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-27 Nozzle must be located anywhere on the perimeter of the cooking surface, and aimed at the center of the cooking surface. 480 SQUARE I INCHES MAXIMUM COOKING AREA I MAXIMUM DEPTH OF FUEL (CHARCOAL) MUST NOT EXCEED 6 INCHES LONGEST SIDE DIMENSION I Figure 3-27 JL EX4521 December 13, 2005 43 apter 3 - System Design . .4'. Mesquite Char-Broiler (High Mount Nozzle) Compulsory Nozzle NL1H Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 480 square inches with a longest side dimension of 24 inches, Fuel Depth (Wood) Must not exceed 6 inches Nozzle Location Anywhere over the cooking surface. Nozzle Height 24 inches to 35 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-28 12 Nozzle must be located anywhere 'within the shaded area and aimed at the center of the cooking surface. 480 SQUARE INCHES MAXIMUM COOKING AREA MAXIMUM DEPTH OF FUEL (WOOD) MUST NOT EXCEED 6 INCHES LONGEST SIDE DIMENSION FL EX4521 December 13, 2005 L Figure 3-28 44 Page rev. C Part# 10053 Chapter 3 - System design Mesquite Char-Broiler (Low Mount Nozzle) Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection 480 square inches with a longest side dimension of 24 inches Fuel Depth (Wood) Must not exceed 6 inches Nozzle Location Anywhere on the perimeter of the cooking surface. Nozzle Height 15 inches to 24 inches above the cooking surface. Nozzle Aiming Aimed at the center of the broiler. Graphic Representation See figure 3-29 and aimed at the center of the cookinr surface. 480 SQUARE INCHES MAXIMUM COOKING AREA MAXIMUM DEPTH OF FUEL (WOOD) MUST NOT EXCEED 6 INCHES LONGEST SIDE DIMENSION Figure 3-29 IL EX4521 December 13, 2005 45 Page rev. C Part # 10053 apter 3 - System Design Upright/Salamander Broiler Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection Internal chamber of 36 inches wide by 28 inches deep. Nozzle Location Above the grate at the front edge of the broiler. Nozzle Aiming Aimed at the back opposite corner of the broiler chamber, and pointed parallel to the broiler grate. Graphic Representation See figure 3-30 i- . Nozzle must be located at thefront of the broiler above the grate, pointedparallel to the broiler grate, and aimed at the opposite corner A Figure 3-30 Page rev. C IL EX4521 December 13, 2005 46 Part # 10053 JL EX4521 December 12, 2006 Page rev. C 47 - Part # 10053 Figure 3-31 NOZZ 1-3 IN( CHAP TO SU NOZZLEAIMED AT DIAGONALLY OPPOSITE CORNER 1 Chapter 3 - System design Chain Broiler Compulsory Nozzle NL1L Flow Points Per Nozzle 1 (One) Number of Nozzles Required 1 (One) Maximum Area of Protection Internal chamber of 27 inches wide by 38 inches deep. Nozzle Location 1 to 3 inches above the surface of the chain at the front edge of the broiler. Nozzle Aiming Aimed at the back opposite corner of the broiler chamber, and pointed parallel to the chain surface. Graphic Representation See figure 3-31 I Nozzle must be located anywhere within the shaded area,pointedparallel to the chain surface, L__and aimed at the diagonally o posite cornei tpter 3 - System Design PIPING LIMITATIONS Once the nozzle placement and quantity of tanks has been determined, it is necessary to determine the piping configurations between the tank and the nozzles. This section contains the guidelines and limitations for designing the distribution piping so that the wet chemical agent will discharge from the nozzles at a proper flow rate. These limitations must also be referred to when selecting the mounting location for the tanks. The maximum pipe lengths are based on internal pipe volume. Each size tank is allowed a minimum and maximum total volume of piping, calculated in milliliters. There is no need to distinguish between what portion of the piping is supply line and what portion is branch line. Only the total volume of the complete piping network has to be considered. Volume Chart 1/4 in. pipe = 20.5 rnls./ft. 3/8 in. pipe = 37.5 mls./ft. 1/2 in. pipe = 59.8 mls./ft. 3/4 in. pipe = 105.0 mls./ft. For more Pipe Volume data, see page 52 TANK CHART Maximum Maximum Volume Maximum Pipe Allowed Between Flow Volume First Nozzle & Last Tank Size Numbers (milliliters) Nozzle (milliliters) r.6 Gallon 5 1500 600 Li600 3.0 Gallon so 1910 1125 L3000 4.6 Gallon 14 3400 3000 L4600 4.6 Gallon rs 2600 2000 L4600 6.o Gallon 19 4215 r658/side L6000 6.o Gallon 20 3465 1313/side L6000 MINIMUM PIPE VOLUMES FOR A FRYER, RANGE, AND WOK Cylinder Size Entire System At or before appliance Woo 239 ml—i Flow Pt iSo ml—i Flow Pt L3000 300 ml-4 Flow Pts 239 ml-2 Flow Pts L4600 66o ml—to Flow Pts iSo mi—s Flow Pts L6000 960 ml-14 Flow Pts 120 ml-2 Flow Pts 'I GENERAL PIPING REQUIREMENTS Split piping and straight piping are both allowed on L1600, L3000 and L4600 systems. L6000 systems must use split piping only, with no nozzle located before the split, and with a maximum of 14 flow points per side. 1/2 in. minimum piping must be used up to the first split. Maximum volume for 1/4 in. pipe between a nozzle and the preceding tee is 410 mls. Maximum flow numbers for 1/4 in. pipe is 6. Maximum number of elbows between a nozzle and the preceding tee is 5. Maximum of 25 elbows are allowed in the total piping system. Maximum difference in elevation betveen the tank outlet and any nozzle is 10 ft. No traps are allowed in the piping network. Pipe lengths are measured from center to center of fittings. The internal equivalent length volume of fittings does not have to be considered as part of the total pipe volume. When utilizing different size pipe in the system, the largest size must start first and the additional pipe must decrease as it approaches the nozzle. Elbow(s) or swivel adaptors located at the nozzles do not have to be counted in the 25 elbow maximum requirement. 13 Reducing bushings are allowed when reducing to a smaller pipe size. 14. Additional piping requirements when protecting a range, wok, or a fryer: L1600 - Minimum of 239 ml and one (1) flow numbers required in total system. Of that minimum, 180 ml and one (1) flow numbers must be utilized at or before the range, wok, or fryer L3000 - Minimum of 300 ml and four (4) flow numbers required in total system. Of that minimum, 239 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. L4600 - Minimum of 660 ml and ten (10) flow numbers required in total system. Of that minimum, 180 ml and two (2) flow numbers must be utilized at or before the range, wok, or fryer. L6000 - Minimum of 960 ml and fourteen (14) flow numbers required in total system. Of that minimum, 120 ml and 2 flow numbers must be utilized at or before the range, wok, or fryer. Page rev. C EX4521 December 12, 2006 48 Part # 10053 PING STRAIGHT PIPING Figure 3-32 Chapter 3 —System Design I SUPPLY PIPE MUST ENTER SIDE OF TEE DESIGN STEPS Step No. 1 Determine number of flow points required based on duct size, plenum size and type, and size of all appliances. Step No. 2 Determine size and quantity of tanks required. Refer ) to the chart in "General Piping Requirements" to determine the maximum amount of flow numbers allowed per each tank size. Step No. 3 Layout nozzles, piping diagram, and tank location. Determine pipe lengths as accurate as possible. Make certain maximum number of elbows is not exceeded. Note: Tanks cannot be manifolded together. Each tank must have a separate piping network. Step No. 4 Add all the lengths of each pipe run and multiply by the mls./ft. listed in the Volume Chart. If the sum falls within the acceptable range noted in general Piping Requirements, that pipe size is acceptable. If the calculated volume is too large, recalculate the volume using the ml per foot of a smaller pipe size. Pipe sizes can be mixed but Rule No. 11 of the General Piping Requirements must be followed. Step No. 5 Check to make certain minimum volumes, maximum volumes and maximum volume allowed between first nozzle and last nozzle is not exceeded (Tank Chart). Check each rule in "General Piping Requirement" to make certain none have been exceeded. If any requirement is exceeded, change to a different pipe size and recalculate. EXAMPLE The cooking area that requires protection consists of a single 48 in. perimeter exhaust duct, a 10 ft. long "V" bank plenum, (2) 18 in. wide x 24 in. fryers, a 30 in. x 36 in. wide griddle, and a 24 in. diameter wok. See Figure 3-33. 18 IN. X 24 IN. FRYERS 30 IN. X 36 IN. GRIDDLE 24 IN. DIAMETER WOK Figure 3-33 Step No. 1: Determine number of flow points required. 48 in. perimeter duct requires one one-flow nozzle 10 ft. "V" bank hood requires one one-flow nozzle 18 in. x 24 in. fryer requires one two-flow nozzle 18 in. x 24 in. fryer requires one two-flow nozzle 30 in. x 36 in. griddle requires one one-flow nozzle 24 in. diameter wok requires one one flow-nozzle TOTAL FLOW NUMBERS -8 Step No. 2: Determine size and quantity of tanks required. Referring to the chart in "General Piping Requirements," an L3000 and an L4600 can supply 10 flows, therefore, an L3000 can be used. C. Page rev. C L EX4521. December 13, 2005 49 Part # 10053 apter 3 - System Design * Step No. 3 Make an accurate sketch of the cooking lineup and the hood. Sketch in the tank location and all the piping required for the total system. Make certain all pipe lengths and number of elbows are as accurate as possible. Check the "General Piping Requirements" to determine that the minimum and maximum requirements are met. See Figure 3-34. Figure 3-34 Step No. 4: Total all pipe lengths. Refer to the Volume Chart. Chose a given pipe size and multiply the ml per foot 1 - \ : by the total length of all the pipe. If the sum falls within the acceptable range noted in Tank Chart, that pipe size is acceptable. If the calculated volume is too large, recalculate the volume using the ml per foot of a smaller pipe size. See Figure 3-35 Add section A-B = 0'-6" + 5'+ 14'+ 2+ 0'-6" = 22' Add section B-C = Add section C-D = 1' Add section D-E = 2' Add section E-F = 0'-6" Add section F-L = 3' + 2' + 2" = 7' Add section B-G = 0'-6" Add section C-H = 2' + 2'= 4' Add section D-I = 2' + 2 = 4' Add section E-J = 0'-6" + 0'-6" = 1' Add section F-K = 2' + 2' = 4' Total length of all pipe = 47'-6' Refer to Volume Chart. The pipe size chosen is 3/8 inch. The volume per foot of 3/8 in. pipe is 37.5 ml. Multiply 37.5 by the total pipe length of 47.5 ft. 37.5 ml x 47.5 ft. = 1781 ml total volume The maximum volume allowed for an L3000 is 1910 ml, therefore, 3/8 in. pipe is acceptable for this system. kE )K I I B A 5. 14 I 2 Figure 3-35 ft Page rev. C EX4521 December 13, 2005 50 Part # 10053