Loading...
HomeMy WebLinkAboutDWG 461-9; 3840; FOXES LANDING SEWER LIFT STATION UPGRADE; 01-07PROJECT LOCATION 0 CONSTRUCTION PLANS FOR FOXES LAND NG .....-1-------PROJECT VICINllY SEWER LFT STATON UPGRADE VICINITY MAP NOSCALE Iii l.OCUSI' 11/f. 100A 1B' LOCATION MAP N.TA _.hPI\ YORAES/PHAM & ASSOCIATES CONSULTING ELECTRICAL • MIICIIANICAL ENGINURS 2131 PAL.OMAR AIRPORT RD .. SlE. 120 CARLSBAD CA. 82011 (700) 431-7177 ~~~~ -,NIT, 102J'Z\ ~-6/30/09 (<CTR\C:.~ ~ CITY OF CARLSBAD CARLSBAD, CALIFORNIA . SHEET INDEX M2. OE8Ci?I IIQN 1 11TlE f.w EL, 2 STAN')AfD aECTflCL 8YMBOL8 AN') ABB IEMA110NB 3 B.ECTRICAL &IE PLAN 4 8tQ.E LtE CIAGIAM S Uf PEJ i AN') LOWER B.ECTAICAL PLAN8 JANUARY 2009 8 8ECT10N PLAN 1 a ca ICATIONB BOARD OF DIRECTORS CLAUDE A. "BUD" LEWIS-MAYOR ANN J. KULCHIN-MAYOR PRO TEM MARK PACKARD-COUNCIL MEMBER MA TT HALL-COUNCIL MEMBER KEITH BLACKBURN-COUNCIL MEMBER LISA HILDABRAND-CITY MANAGER WARNING 0 1/2 1· IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE. REVIEWED BY: "AS-BUILT" 5/11/(o DATE EXP. ~13~/11 T-1 fsHEETl CITY OF CARLSBAD I SHEETS I 1-------+------1---------1---+--+------+------t L_1_J ENGINEERING DEPARTMENT 7 l-------+------1---------1---+--+------+------t FOXES LANDING SEWER LIFT STATION UPGRADE TITLE SHEET APPROVED BY: WILLIA!i4, ~ PLUMMER >------+------1---------1---+--+------+------1 /4-.J;<&,; ~ ---p4'W7~#.. I-Id ,,79 DEPUTY CITY ENGINEER PE 28178 EXP. 3-31-10 DATE t--------+-----t--,..----------,.-----,..--,==--------i---------t---t------+-----t t 45 BUILT OWN BY: PROJECT NO. I DRAWING NO. DATE INITIAL ,___□_ATE~INITI_AL--+------DAT_E ~IN_ITl/\_,L CHKD BY: JM 3840 461-9 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CllY APPROVAL RWID BY: JMM STANDARD ABBREVIATIONS COND!,!II SltlGI..E UtlE SOll;:MAill:: DES!::RIPilOtl CONi)!.!II SltlGLE Ul!!I;; SC!:JEMAill:: DESCRIPilOtl COl!!D!.!II SJt,!GI..E UNI;; Srni;;MAilC DESCRIPlJON f1.AN. DIAGRAM DIAGRAM fl.AN. DIA!.BAM !llAGRAM fl.AN. !llA!.RAM DIAGRAM A AMPERES MAX MAXIMUM AC AL TERNA TING CURRENT MC MAINTAINED CONTACT ")100,&.f :) CIRCUIT BREAKER. UPPER NUMBER IS FRAME SIZE. IT] UJJJ POWf:R TRANSFORMER. RA TINGS AS NOTED $M MANUAL MOTOR STARTER AF AMPERE FRAME MCC MOTOR CONTROL CENTER o 50AT LOWf:R NUMBER IS TRIP RA TING rnTl ON DRAWINGS AFC ABOVE FINISHED CONCRETE MCM TI-IOUSAND CIRCULAR MILS AFF ABOVE FINISHED FLOOR MCP MOTOR CIRCUIT PROTECTOR TI-iREE POSITION SWITCH. MAINTAINED CONTACT DUPLEX RECEPTACLE. 20A, SPEC GRADE _J_ _J_ _J_ AFG ABOVE FINISHED GRADE MH MANHOLE 0 <JP AT AMPERE TRIP MIN MINIMUM OR MINUTE ■ ~-FUNCTION MAY VARY AS NOTED ON DIAGRAMS. GROUNDING TYPE. UNLESS OTI-IERWISE NOTED ---GROUND ATS AUTOMATIC TRANSFER SWITCH MLO MAIN LUGS ONLY CENTER POSITION IS OFF ON DRAWINGS. ------AUX AUXILIARY MOY MOTOR OPERATED VALVE ACTUATOR --AUTO AUTOMATIC MTG MOUNTING ■ ✓ TWO POSITION SWITCH. MAINTAINED CONTACT ◄ TELEPHONE OUTLET ans-oJV1flo oJV1flo HEATER, RATING AS NOTED ON DRAWING AWG AMERICAN WIRE GAUGE MTR MOTOR 0 FUNCTION MAY VARY AS NOTED ON DIAGRAMS BC BARE COPPER N NEUTRAL --BO BOARD NA NON-AUTOMATIC JUNCTION BOX OR CONDUIT FITTING AS NOTED OR □ □ BKR BREAKER NC NORMALLY CLOSED ■ ....Lo MOMENTARY CONTACT PUSHBUTTON. FUNCTION 0 REQUIRED. HORN OR AUDIBLE SIGNAL C CONDUIT NCIO NORMALLY CLOSED, MAY VARY AS NOTED ON DIAGRAMS (SHOWN WITI-i CONDUIT TURNING UP) CAB CABINET INSTANTANEOUS OPEN -----• --CB CIRCUIT BREAKER NCTC NORMALLY CLOSED, ■ ti 0 CKT CIRCUIT TIME CLOSE LOS MOMENTARY CONTACT PUSHBUTTON WITI-i PROVISION ■LS LEVEL SWITCH, CONTACT ACTION ANNUNCIATOR ALARM WINDOW CLG CEILING NCTO NORMALLY CLOSE, LOS ....Lo FOR LOCKOUT. AS NOTED ON DRAWINGS c.o. CONDUIT ONLY TIME OPEN -----~--~ COMPT COMPARTMENT NEC NATIONAL ELECTRIC CODE D .-. .-. COND CONDUCTOR NIC NOT IN CONTRACT a l l LOCKABLE DISCONNECT SWITCH. RA TING AND CONTROL PANEL OR EQUIPMENT AS NOTED fi!J fi!J {IJ PHASE CONT CONTROL No NUMBER DETAILS AS NOTED ON DRAWINGS. '--__J '--__J CONTD CONTINUEO NO NORMALLY OPEN -f----CPT CONTROL POWf:R TRANSFORMER NOIC NORMALLY OPEN, ■rs FLOW SWITCH, CONTACT ACTION AS NOTED ON CP CONTROL PANEL INSTANTANEOUS CLOSE ■zs ~ LIMIT SWITCH. NORMALLY OPEN ~ □ TERMINAL, INTERNAL WIRING CT CURRENT TRANSFORMER NOTC NORMALLY OPEN, DRAWINGS cu COPPER TIME CLOSE --CR CONTROL RELAY NOTO NORMALLY OPEN, $ ' DC DIRECT CURRENT TIME OPEN ■zs -LIMIT SWITCH, NORMALLY CLOSED FLUSH TOGGLE SWITCH, SINGLE POLE, SINGLE THROW ■ TERMINAL, FIELD WIRING DISC DISCONNECT NP NAMEPLATE DISC SW DISCONNECT S\'flTCH NTS NOT TO SCALE r DPDT DOUBLE POLE DOUBLE THROW OL OVERLOAD TIME DELAY RELAY CONTACT. $• ■os DPST DOUBLE POLE SINGLE THROW OTT OVERTEMP SWITCH °l"2NOTO OFF DELAY, NORMALLY OPEN, TIME OPEN FLUSH TOGGLE SWITCH, TI-IREE WAY MAGNETIC DOOR SWITCH DWG DRAWING p POLE DS DOOR SWITCH PB PUSHBUTTON r --------EL.ELEV ELEVATION PB PULLBOX TIME DELAY RELAY CONTACT. I I --3 EMT ELECTRICAL METALLIC TUBING PC PHOTOCELL TNCro OFF DELAY, NORMALLY CLOSED, TIME CLOSED FLUORESCENT FIXTURE. SEE LIGHTING SCHEDULE. CONDUIT STUB OUT ED ELECTRICALLY OPERA TED PCV PUMP CONTROL VALVE EXIST EXISTING PH PHASE $xx DISCONNECT S\'flTCH, F = FUSED FBO FURNISHED BY OWNER PMR POWf:R MONITOR RELAY "};:!Nero TIME DELAY RELAY CONTACT. l-0 LIGHTING FIXTURE, WALL MOUNTED rE:Pxx NF = NON-FUSED FDR FEEDER PNL PANEL ON DELAY, NORMALLY OPEN, TIME CLOSED SEE LIGHTING SCHEDULE XX = AMP RA TING FIN FINISHED POS POSITION --------~ FLA FULL LOAD AMPS PR PAIR ~ -~-FLEX FLEXIBLE PRI PRIMARY ANCro TIME DELAY RELAY CONTACT. E::3 EMERGENCY LIGHTING UNIT, SELF CONTAINED. 0 '1' DENOTES: TELEMETRY POINT VIA PLC FM FLOW METER PS PRESSURE SWITCH ON DELAY, NORMALLY CLOSED, TIME OPEN 'p' DENOTES: PLC INPUT (SCADA) FS FLOW SWITCH PT POTENTIAL TRANSFORMER ---FT OR' FEET OR FOOT PVC POLYVINYL CHLORIDE -----FT FLOW TRANSMITTER PVC/RCS □ PVC JACKETED RIGID ■sov + SOLENOID OPERATED VALVE MH-MANHOLE PB-PULLBOX HH-HANDHOLE 0 0 CONDUIT NO. XX, REFER TO CONDUIT SCHEDULE FUT FUTURE GALVANIZED STEEL CONDUIT PB OR AS NOTED ON DRAWINGS FVNR FULL VOLTAGE NON REVERSING PW PART WINDING ~ -CALV GALVANIZED RECEP RECEPTACLE CD GAS DETECTORS RGS RIGID GALVANIZED STEEL CONDUIT --<~ --<~ MOTOR CONTROL CENTER DRAWOUT STABS -r-TELEPHONE CONDUIT. SIZE AS NOTED CFI GROUND FAULT INTERRUPTER RTU REMOTE TERMINAL UNIT CFP GROUND FAULT PROTECTION RVAT REDUCED VOLTAGE AUTO TRANSFORMER ~ ~ ----GND OR C GROUND RVYD REDUCED VOLTAGE WYE DELTA 2 GROUNDING GRID OR GROUNDING CONDUCTOR HH HANDHOLE SDG&:E SAN DIEGO GAS &: ELECTRIC 181 MOTOR STARTER \'flTH TI-iERMAL OVERLOADS. -G-HOA HAND/OFF/AUTO SEC SECONDARY -11--o".XJ+ NUMBER INDICATES NEMA SIZE SIZE AS REQUIRED OR AS NOTED ON DRAWINGS HTR HEATER SEL SELECTOR -----IC INTERRUPTING CURRENT SP SPARE OL -o-!-IN OR• INCJ,ES OR INCH SPEC SPECIFICATION :.1-t MOTOR OVERLOAD CONTACT GROUND PIGTAIL. SIZE AS NOTED ON DRAWINGS IND INDICATING ss STAINLESS STEEL INST INSTANTANEOUS SPOT SINGLE POLE DOUBLE TI-iROW ~---------INSTR INSTRUMENT SPST SINGLE POLE SINGLE THROW 0 0 1 INTLK INTERLOCK ST SHUNT TRIP .-©-MOTOR, NUMBER INDICATES HORSEPOWER G-EXOTHERMIC GROUND CONNECTION JB OR J JUNCTION BOX, CONDULET OR STA STATION ATTING AS REQUIRED BY NEC. STL STEEL INDICATING LICHT, PUSH-TO-TEST. LETTER UNLESS 01HERWISE NOTED STP SHIELDED T\'flSTED PAIR --m KW KILOWATTS STR STARTER INOICA TES COLOR. 0 CONDUIT BENDING UP LCL LONG CONTINUOUS LOAD STT SHIELDED TWISTED TRIPLET -R=RED B=BLUE G=GREEN A=AMBER W=WI-IITE LCP LOCAL CONTROL PANEL sv SOLENOID VALVE -----LEV LEVEL SW SWITCH 0 CONTACTOR OR RELAY COIL. LETTER OR • LIM LIMIT SWBD SWITCHBOARD NUMBER IS DESICNA TION CONDUIT BENDING DOWN LR LOCAL/REMOTE TB TERMINAL BOX LOS LOCKOUT STOP STATION TEL TELEPHONE -----~ ---~--~-------LS LEVEL OR LIMIT SWITCH TEMP TEMPERATURE M ..t-t NORMALLY CLOSED CONTACT. LETTER OR LT LIGHT TERM TERMINAL NUMBER IS DESIGNATION --UNDERGROUND OR CONCEALED CONDUIT LTG LIGHTING 1M TELEMETRY LY LOW VOLTAGE TS TEMPERATURE S\'flTCH M MA MILLIAMPERE TS2W TWO SPEED TWO WINDING -If-NORMALLY OPEN CONTACT. LETTER OR EXPOSED CONDUIT. MAINT MAINTAINED TVSS TRANSIENT VOLTAGE SURGE SUPPRESOR NUMBER IS DESIGNATION MAN MANUAL TW/SH T\'flSTED SHIELDED -TYP TYPICAL e I#. HOMERUN CONDUIT. HASHMARKS INDICATE UNGNO UNDERGROUND RUNNING TIME METER, NON-RESETTABLE J CONDUCTORS, NEUTRAL AND GROUND, LION UNLESS OTI-IERWISE NOTED PB1 1,3,5 CIRCUITS 1,3,5 PANEL PB1 V VOLTS VFD VARIABLE FREQUENCY DRIVE o--0-® w WATTS FUSE, NUMBER INDICATES RA TING DRIVEN GROUND ROD -3/4• X 10' Cu CLAD STEEL W/ 1',11H W/0 WITHOUT -~-----WP WEATHERPROOF "'UJ..UJO CONTROL TRANSFORMER. RA TING AS NOTED ON XFMR TRANSFORMER + DRAWINGS OR AS REQUIRED BASED ON LOAD -PANELBOARD OR AS NOTED ON DRAWING XP EXPLOSION PROOF SERVED. ZS POSITION SWITCH OR LIMIT S\'flTCH -3W THREE WIRE 6) 4W FOUR WIRE KILOWATT METER \NV\,. LIQUIDTICHT FLEXIBLE CONDUIT - ■Ps '); PRESSURE S\'flTCH. CONTACT ACTION AS NOTED 0 °so THERMOSTAT ON DRAWINGS E-1 "AS-BUILT" I SH~ET I CITY OF CARISBAD I SH~EIS I ENGINEERING DEPARTMENT mrkv FOXES LANDING ~/4/iu SEWER LIFT STATION UPGRADE DATE STANDARD ELECTRICAL SYMBOLS AND y~ESSrs WARNING P.E. t/lPZ3 EXP. 6/1,,(/1 ABBREVIATIONS ~1~46 ~ ' ..JK)l\_ MORAES/PHAM & ASSOCIATES 1/2 1· APPROVED BY:ll~LUMMER 0 CONSULTING l!Ll!Cl'IUCAL II lolllCHANICAL ENGINEERS 9 ">No. ~10~ I REVIEWED BY: ~?✓Yi, w:v••t /-t,5--r29 ~-63009 DEUTY CITY ENGINEER PE 28176 EXP, 3-31-10 DATE 2131 PALOMAR AIRPatT RD., STE. 120 * ( '-.1 • IF THIS BAR DOES NOT MEASURE 1" ~ 1_) G't b-'l/o Vl\ AB /ill/LT DWN BY: I PROJECT NO. I DRAWING NO. CARtS8AD CA. 92011 (780) 4'1-7177 J), <CTR\<:,~ THEN DRAWING IS NOT TO SCALE. DATE INITIAL DATE INITIAL DATE INITtAL CHKD BY:JM Cf~ (I<' CAt~ ~/JJ,/gi CTOR • ( REVISION DESCRIPTION 3840 DATE ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RYWD BY, JMM 461-9 • 00 00 00 00 00 00 0 0 0 0 0 0 0 0 0 .. x r :r ,---------, -----'I -----'I ----'I ----'I ·! X 1----- -----'I ----'I ,---'I l 1_· '---- l .,, 'I x y J X [ CONTROL BUILDING 1-------□--7 : 0 □□□□□ : iG VFD-1 {EXISTING) D I \ roJ VFD-2 (EXISTING) r1 I \ \,QJ VFD-3 (EXISTING) ll I ·.---~ L-,-L-,-~-,-~----~ r I 1 1 , 0 1 EXISTING 2• CONDUITS PF-3~ PF-2~ PF-1~ X X X I I \ ' ± -~-1-1-------------------------------------\ , ______________ ----- -----------------------ELEC PB I '------------------r----- 1 I ! I I ! l □0 I \_ MCC (EXISTING) _J L __________ _ 0 0 0 0 NOTES: 0 REPLACE EXISTING VFD CONDUCTORS WllH (4)#4 AWG OIL RESISTANT SHIELDED VFD CABLE AND SPLICE INTO EXISTING PUMP LEADS AT SPLICE BOX IN DRY WELL THE VFD CABLE BENDING RADIUS SHALL NOT EXCEED 9 INCHES. r,;,. REPLACE EXISTING CONTROL WIRE WllH (8)#12 AND (1)612 GND. SPLICE CONTROL WIRE INTO \V EXISTING CONTROL WIRE AT SPLICE BOX IN DRY WELL .JK>I\._ MORAES/PHAM & ASSOCIATES CONSlJLTING ELl!CTIIICAL a, IIBCIIANICAL ENGINlllllS 2131 PAI..Oti&AR AIRPORT RO •• STE. 120 CARLS8AD CA. 92011 (760) 431-7177 ------------------ X • ► X ttt I I x' I I I I ' I I / I I f -_j X X X WARNING 0 1/2 1 • IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE. X - X X X X "AS-BUILT" P.E. _ __.e:;fi.u.1/.::.,oZ.~~"----- REVIEWED BY: ,/;9/(p DATE EXP. (, ($",/If (,, q,fo DATE X I 'I 'I_____,-- '/-----'I----- 'I-----'I ----- c-'1-------'l-----'/----- / / -----'I~ -----'/ / X -----'I / -----'I \ \ X / / X I I I X I I I / X X / / / □□ X L / I. / / I X X X Ix .Jc I ~ X X X \X X X I I X X X ~ ~x ~x X dx x~ X NOTE: SCOPE INCLUDES SUPPLY OF PORTABLE POWER ANALYZER. SEE E-6 SPECIFICATIONS. E-2 ISHEEi7 CITY OF CARI.SBAD I S~EETS I 1----1----1----------------t----t--t----------t---i ~ ENGINEERING DEPARTMENT 1----1----1----------------+----t--t----------t---i FOXES LANDING SEWER LIFT STATION UPGRADE ELECTRICAL SITE PLAN AP.PROVED BY: WIL!:!¢,M,!: PLUMMER ~/1, · L~,,,,-w, 1-1,:1-09 DEPUTY CITY ENGINEER PE 28176 EXP. 3-31-10 DATE 1 AS IJ(J/LT DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: PROJECT NO. I DRAWING NO. CHKD BY: Jt.4 3840 461-9 RVWD BY: JMM l----7 I I I I NEMA I GASKETED IN NEMA 3R ENCLOSURE 1\.AAA)7 I /YYY'\ I 400A (MIN.) l: --1--'.J AUTOMATIC NEMA 12 NEMA 12 NEMA 12 MAIN I PUU. SERVICE TRANSFER r ENCLOSURE ENCLOSURE\ ENCLOSURE\ CONTROL II llstcnj"olH --,SECTION 71 '1 swrrCH_j_ -i-G --- -- --- ---l ---400A COPPER eus. 8RACEDM:R so,OOOA RMS (MIN.)-- - - - - - - - - --- --T PANEL 7 r---r------~-r----r----1----T----r---------t-------r--------t-----------1-I I II II I '-~ I I II I -1, 115" Ol Ol Ol "' 115" 115" 1200A I"°" I I I ..... M~•~R r, r ( ... -2.8" ( ... -2.8" ('O 2.8" ( ... -1.6" r 3P r JP r ~ 2P I I <I> ( M\ II I L.J .I. .I. MAIN t I I I I "'t// =io8·r.:l~ I r.'I I r.l.71 r 71 r 71 r.l.71 1 1 11 \.A A) ~~ I I I I '-.'.I I I / 1sIzE I / 1sIzE I / 1sIzE I / 1sIzE I I rvyv-.. 120/240 II I IPROTECTIONANDI I I / / / / I I I I I I I l,. TEST S)'Slt:M. ,--_.___, I IL_ _j O IL_ _j O IL_ _j O IL_ _j O I .!,, L 40lW' I I T T ,: T I I I 19°" _..J J I 300AT I I ►, I lVSS I I I i2s2w I I I I i' 2P I I L r J □ '--=-.... I I I I I I I I r-.J.-, I L----i ___ M.ef---J--">/ I 0) I @ 1 I I I I I I I I u1tiJG I I I f 8 -~~~0 l"Tl-I 1-.1 'Y I I I I I I I I I L~~~{ (?) I I I 111 I I I I I I I I /~,N~JRCUIT I L ___ _J L -L-1 _j_ -_l__ - - - --1---1---+ - -t---1-- - --1-- --1-- - -_I_ - - - - - - - -_L_ -_J I I I I £I 121 :fl t.-1 ~I 11!1 gt ~I I I I I "-I "-I "-I ltl ltl "-I 1t1 L--------~-~M..J!£:J?.R.QYfil)_j I I .1 ..J ..J ..J ..J l l I I r 7 / .. ,\ / ''\ / ... \ / ;'\ PF9A 1 7 1 7 PFIOA co~ _________ ...!,1.Jl!l _____ ..J I I I \ 1 I \ 1 I \ 1 I \ 1 21 r----i I I l----1 1--~ I LT...I -..._. -..._. -..._. -..._. ..J..._ L _ _j L _ _J .,.J..._ I G L ..,-... J ..J SUPPLY EXHAUST SUPPLY EXHAUST / S \ COMMINUTOR COMMINUTOR I S \ \ ; ------------~-..._ FAN FAN FAN FAN \ No.1 No.2 \ '---3P / 5 \ No.1 No.1 No.2 No.2 -... _,I -... _,I EXIST. 135 KW \, I DRY WELL ORY WELL WET WELL WET Will COMMINUTOR COMMINUTOR .f2_~ 00 .... 0R No.1 No.2 =~u-• HYDRAULIC HYDRAULIC JJ!lf8.W,R SCRiiBER I - - ---- --- -- --DRIV~ - - - -fg~~T=\ DRIVE 400A COPPER BUS, BRACED fOR 50,000A RMS (!.!IN.) .J I r------------r------------1----r---- l (~,°°" (~10°" ~1°°" I I .r---, .r---, 1---, I I rI, I rI, I rcoNT...cToR rI, I I I I .L I I .I.I (1YP.) I I .L I IVFDI T 1VFD1 T IVFDI T I LIJ I LIJ l LIJ I I J---J J---J J--~J I I ~ ~ ~ I L ________ -------~~--~ SINGLE LINE DIAGRAM MATERIALS LIST /NOTES FOR SINGLE LINE DIAGRAM Q) EXISTING POWER MONITOR OR lVSS. @ REPLACE EXISTING VFD CONDUCTORS WITH 4£/#4 AWG OIL RESISTANT SHIELDED VFD CABLE AND SPLICE INTO EXISTING PUMP LEADS AT SPLICE BOX IN ORY WELL @ ADO NEW lVSS BUCKET WITH DRY CONTACT TO MCC UNIT 2A. THE DISTRICT WILL PROVIDE CONNECTION BETWEEN lVSS ORY CONTACT AND TELEMETRY. PROVIDE CUSTOM ENGRAVING WITH EQUIPMENT NAME. MATCH EXISTING ENGRAVINGS. © REPLACE EXISTING CONTROL WIRE WITH 8#12 AND 1#12 GNO. SPLICE CONTROL WIRE INTO EXISTING CONTROL WIRE AT SPLICE BOX IN ORY WELL "AS-BUILT" ' I ' I ~ >-- ~ I \ I SECURITY 0± : I TELEMETRY I WIREWAY . _LJ • " -. . . . --. - L I 20" DEEP 30" - SECT 1 SECT 2 SECT J SECT 4 SECT 5 ~-~ MAIN CONTROL ~ '~ ! , IJl'f'LY FAN -,..a NO. 1 1/fD #I •• AUTOMATIC 1----""IL,~oRYWEU.::~~;;;;;-~'j TRANSFER UGHllNG I,' \lfD #2 '"' SWITCH \ D<IJ:i_Fr' ORYWEU. I -VF!)_ I!-.l-.r~ ~~ - t ,__/ 9.J~Y ["" NO~ ~ --IV/ -~ 20 WEfWEl.1. COMMINUTOR & ~ >-----=t NO. • •• ,._....._ I 11WISFORWfR COIIIIINlJIQR r-NO. 3 u 31 COOR 1---EXH-. -FAN--=! SCRU8llEll •• NO. 2 WE1WEU. V POWER IIONllOI! SPARE I.IGH11NING ., IA 2M "Q ARRESTOR 4V \_ PROVIDE MCP WITH BACK BOARD FOR MOUNTING REI.AYS AND CONTROL DEVICES - - ... - L 3• HIGH GROUT PAD (lYP.) EXISTING SQUARE 'D' MODEL 6 MCC EXISTING MCP, MCC, AND ATS ELEVATION SCALE: 1/2"=1'-0" E-3 rSHEEfl CITY OF CARI.SHAD I SHE7ETS I 1----+----< L__±_j ENGINEERING DEPARTMENT l------+---lf-----------------+-----1--+---+---I ..Jtt'>I\._ MORAES/PHAM & ASSOCIATES CONSULTING l!LBCTRICAL & l(l!CIIANICAL BNGINl!l!R8 2131 PAl..(NAR AIRPMT RD,, STE. 120 CAAI.SBAD CA. 92011 (100) "'1-71n WARNING 0 1/2 1 • IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE. P.E. ---"f;-"//""Pt=3'---- REVIEWED BY: s-/Mftu FOXES LANDING SEWER LIFT STATION UPGRADE DATE EXP. ~(!o/f! SINGLE LINE DIAGRAM APPROVED BY: WILLIAM E. PLUMMER ~ t'. ~t ,,-n--,. I-,,,. 1------+---lf-----------------+-----+--+---+---I DEPUTY CITY ENGINEER PE 28176 EXP. J-31-10 DATE' (o,9 ,to_ 1----D_A_TE-+_IN_ITI_AL_, DATE 11\ AS 8{1/lT ENGINEER OF WORK REVISION DESCRIPTION DA TE IN IT!AL OTHER APPROVAL DATE INITIAL CITY APPROVAL OWN BY: I CHKD BY:J =M~- RVWD BY: JMM . PROJECT NO. 3840 I DRAWING NO. 461-9 NOTES: 0 EXISTING ELEClRICAL PULLBOX. ® EXISTING COVERED CABLE lRAY. @ EXISTING NEMA 12 JUNCTION BOX. a a ORY WELL ► UPPER LEVEL PLAN SCALE: 3/8"=1'-o" ~ MORAES/PHAM & ASSOCIATES CONSULTING l!LBCTRICAL o!t lll!CIIANICAL BNGINEl!ll8 21J1 PALOMAR AIRPORT RD .. STE. 120 CARLSaAO CA. 02011 (780) ..,_,,n FROM EXISTING CONlROL BUILDING WET WELL a rs G> G> @Ji WARNING 0 1/2 1" If THIS BAR DOES NOT ME'ASURE 1" THEN DRAWING IS NOT TO SCALE. "AS-BUILT" P.E. _.;c&:--'!~lo-'--Z-.,,_3 __ _ EXP. R~IEWEO BY: PUMP 1 Q] 0---~f"'Fil+k DRY WELL WET WELL PUMP 2 PUMP 3 LOWER LEVEL PLAN SCALE: 3/8"=1'-0" E-4 fsHIBl CITY OF CARI.SHAD I SHE,ETS I >----+-----if----------------+-----;r--+---+----t ~ ENGINEE ING DEPARTMENT >----+-----if----------------+-----ir--+---+------t 1 498. I/LT DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL FOXfS LANDING SEWER LIFT STATION UPGRADE UPPER AND LOWER ELECTRICAL PLANS APPR_9'!'.E0 BY: Wl~LUMMER /4 p?At-t,; e ~,,... i-1~ DEPUTY CITY ENGINEER PE 28176 EXP. 3-31-10 DATE OWN BY: CHKO BY: ,.,.JIA~~ RVWO BY: Jt.11,1 PROJECT NO. 3840 I DRAWING NO. 461-9 ~ FROM EX STING ~ CONTROL BUILDING , /2 PF-1-1/ ~~ =~ ::-::_· I r0 , ~==-------.. I I 0 0 0 l ~ L____ _ ___,_l_J__L___J_ ___ rl---'fr-----+--1r------r:l----frl ----------,).11"',-l---J I I I I ~£ I ~ 0 I I 181 ,=,-= 1c c' p -I = T v- 11 'I_.J_J (5)1 ® f / ;: , DRY WELL SECTION ',E-5_., SCALE: 3/8"=1'-0" NOTES: 0 EXISTING ELECTRICAL PULL BOX. ® EXISTING COVERED CABLE TRAY. @ EXISTING NEMA 12 JUNCTION BOX. I 0 EXISTING NEMA 12 PUMP CABLE SPLICE BOX. 11 - ~ 00 • I ~ ' -@ 0 ® ® SPLICE SHIELDED VFD CABLE INTO EXISTING MOTOR CONDUCTORS. ® EXISTING POWER AND CONTROL CABLES. .JtPI\. MORAES/PHAM & ASSOCIATES CONSULTING ILECTRIC.U. lo MBCIIANIC.U. ENGINEBRS 2131 PAI.DMAR AIRPORT RO., SlE. 120 CARLSBAD CA. 92011 (7fl0) 431-7177 0 WARNING 1/2 1· . IF THIS BAR DOES NOT MEASURE 1 " THEN DRAWING IS NOT TO SCALE. /I 0 REVIEWED BY: I/ ~CTOR ( "AS-BUILT" ;//'1/rl7 DATE EXP. ~l»/11 E-5 [sHml CITY OF CARLSBAD I SH;ETS I 1-----+--+-----------------+---t----1---1------1 ~ ENGINEERING DEPARTMENT l-----+--+-----------------+---t----+---t------1 II/\ 4S 8/J/LT DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL FOXES LANDING SEWER LIFT STATION UPGRADE SECTION P(AN APPROVED BY: WI~ PLUMMER ,n/4¼ . t: ~ • -~ ,-~<~"'- DEPU'IY CllY ENGINEER PE 28176 EXP. 3-31-10 DATE. OWN BY: .. I PROJECT NO. I DRAWING NO. CHKD BY:J=M~_ ~---3_8_40 ___ ~ 461-9 RVWD BY: JMM . Vl C) :r ~ rt> G) rt> ,.... en .i::, 0 en ...... .... • -...J I \.0 SECTION 16000 ELECTRICAL WORK PART 1 -GENERAL 1.1 DESCRIPTION A. WORK INCLUDED: PROVIDE COMPLETE ELECTRICAL AS SHOWN ON THE DRAWINGS, AS SPECIFlED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION INCLUDING, BUT NOT NECESSARILY LIMITED TO: 1. FEEDER SYSTEM, IN CONDUIT TO BRANCH CIRCUITS. 2. BRANCH CIRCUIT WIRING, IN CONDUIT, FOR LIGHTING, RECEPTACLES, JUNCTION BOXES, AND MOTORS. 3. HANGERS, ANCHORS, SLEEVES, CHASES, SUPPORTS FOR FlXTURES, AND OTHER ELECTRICAL MATERIALS AND EQUIPMENT IN ASSOCIATION THEREWITH. 4. WIRING SYSTEM, IN CONDUIT, FOR EQUIPMENT AND CONTROLS PROVIDED UNDER OTHER SECTIONS OF THESE SPECIFICATIONS. 5. OTHER ITEMS AND SERVICES REQUIRED TO COMPLETE THE SYSTEMS. 1.2 QUALITY ASSURANCE A. USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFlED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK OF THIS SECTION. ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NFPA70). B. WITHOUT ADDITIONAL COST TO THE OWNER, PROVIDE SUCH OTHER LABOR ANO MATERIALS AS ARE REQUIRED TO COMPLETE THE WORK OF THIS SECTION IN ACCORDANCE WITH THE REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, REGARDLESS OF WHETHER SUCH MATERIALS ANO ASSOCIATED LABOR ARE CALLEO FOR ELSEWHERE IN THESE CONTRACT DOCUMENTS. 1.3 SUBMITTAL A. PRODUCT DATA: WITHIN 35 CALENDAR DAYS AFTER THE CONTRACTOR HAS RECEIVED THE OWNER'S NOTICE TO PROCEED, SUBMIT SIX (6) COPIES OF: 1. MATERIALS UST OF ITEMS PROPOSED TO BE PROVIDED UNDER THIS SECTION. 2. MANUFACTURER'S SPECIFlCATIONS ANO OTHER DATA NEEDED TO PROVIDE COMPLIANCE WITH THE SPECIFIED REQUIREMENTS. 3. MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES WHICH, WHEN APPROVED BY THE OWNER WILL BECOME THE BASIS FOR ACCEPTING OR REJECTING ACTUAL INSTALLATION PROCEDURES USED ON THE WORK. B. MANUAL: UPON COMPLETION OF THIS PORTION OF THE WORK, ANO AS A CONDITION OF ITS ACCEPTANCE, DELIVER TO THE OWNER TWO (2) COPIES OF AN OPERATION ANO MAINTENANCE MANUAL INCLUDE WITHIN EACH MANUAL: 1. COPY OF THE APPROVED RECORD DOCUMENTS FOR THIS PORTION OF THE WORK. 2. COPIES OF ALL CIRCUIT DIRECTORIES. 3. COPIES OF ALL WARRANTIES AND GUARANTIES. 4. CONTROL SCHEMATICS. 1.4 WARRANTY A. PROVIDE ONE YEAR WARRANTY ON ALL LABOR AND MATERIALS FROM THE DATE OF COMMISSIONING. PART 2 -PRODUCTS 2.1 GENERAL WHERE UNDERWRITERS' LABORATORIES, INC. HAVE ESTABLISHED STANDARDS FOR SUCH MATERIALS, PROVIDE ONLY MATERIALS BEARING THE UL LABEL 2.2 NOT USED 2.3 NOT USED 2.4 DISTRIBUTION SYSTEM A. IDENTIFlCATION: 1. IDENTIFY ALL APPARATUS USED FOR OPERATION AND CONTROL OF CIRCUITS, APPLIANCES, AND EQUIPMENT. 2. PROVIDE CUSTOM ENGRAVINGS WITH EQUIPMENT NAME. MATCH EXISTING MCC ENGRAVINGS. B. CONDUCTORS: 1. FOR LINE VOLTAGES, PROVIDE 600V INSULATED COPPER WIRE ANO CABLE, NEC STANDARDS, OF TYPES SPECIFIED BELOW FOR DIFFERENCE APPLICATIONS, WITH UL LABEL. AGENCIES HAVING JURISDICTION. 2. WITH CONDUCTORS, PROVIDE INSULATING BUSHINGS OR INSULATING SLEEVES. 2.5 OTHER MATERIALS PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR SUBJECT TO THE APPROVAL OF THE OWNER. ./t'PJ-. MORAES/PHAM & ASSOCIATES CONSULTING ELECTRICAL & IIECIWilCAL ENGINEBRS 2131 PAI.CUAlt AIRPORT RD .. STE. 110 CARLS8AD CA. 9201.1 (700) '31-7177 PART 3 -EXECUTION 3.1 SURFACE CONDITIONS EXAMINE THE AREAS ANO CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE PERFORMED. CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK. 00 NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. 3.2 PREPARATION A. COORDINATION: 1. 1. COORDINATE AS NECESSARY WITH OTHER TRADES TO ASSURE PROPER ANO ADEQUATE PROVISION IN THE WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION. COORDINATE THE INSTALLATION OF ELECTRICAL ITEMS WITH THE SCHEDULE FOR WORK OF OTHER TRADES TO PREVENT UNNECESSARY DELAYS IN THE TOTAL WORK. B. DATA INDICATED ON THE DRAWINGS AND IN THESE SPECIFlCATIONS ARE AS EXACT AS COULD BE SECURED, BUT THEIR ABSOLUTE ACCURACY IS NOT WARRANTED. THE EXACT LOCATIONS, DISTANCES, LEVELS, AND OTHER CONDITIONS WILL BE GOVERNED BY ACTUAL CONSTRUCTION ANO THE DRAWINGS ANO SPECIFlCATIONS SHOULD BE USED ONLY FOR GUIDANCE IN SUCH REGARD. C. VERIFY ALL MEASUREMENTS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF DIFFERENCES BETWEEN WORK SHOWN ON THE DRAWINGS ANO ACTUAL MEASUREMENTS AT THE SITE OF CONSTRUCTION. 0. BRANCH CIRCUIT WIRING AND ARRANGEMENT Of HOME RUNS HAVE BEEN DESIGNED FOR MAXIMUM ECONOMY CONSISTENT WITH ADEQUATE SIZING FOR VOLTAGE DROPS ANO OTHER CONSIDERATIONS. INSTALL THE WIRING WITH CIRCUITS ARRANGED EXACTLY AS SHOWN ON THE DRAWINGS, EXCEPT AS OTHERWISE APPROVED IN ADVANCE BY THE OWNER. E. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC, BUT ARE REQUIRED TO BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION ANO WORK OF OTHER TRADES WILL PERMIT. WHERE DEVIATIONS ARE REQUIRED TO CONFORM WITH ACTUAL CONSTRUCTION AND THE WORK OF OTHER TRADES, MAKE SUCH DEVIATIONS WITHOUT ADDITIONAL COST TO THE OWNER. 3.3 INSTALLATION OF VFD CABLE ANO CONTROL WIRE A. REPLACE EXISTING VFO CONDUCTORS WITH 4C/#4 AWG OIL RESISTANT SHIELDED VFO CABLE (LAPPUSA PART #760404 OR EQUAL) ANO SPLICE INTO EXISTING PUMP LEADS AT B. SPLICE BOX IN DRY WELL THE VFD CABLE BENDING RADIUS SHALL NOT EXCEED 9 INCHES. REPLACE EXISTING CONTROL WIRE WITH 8#12 AND 1#12 GNO. SPLICE CONTROL WIRE INTO EXISTING CONTROL WIRE AT SPLICE BOX IN ORY WELL. 3.4 INSTALLATION OF POWER EQUIPMENT CONNECTIONS TO MISCELLANEOUS EQUIPMENT: A. WIRE TO, ANO CONNECT TO, ALL EQUIPMENT NOT SPECIFICALLY DESCRIBED BUT TO WHICH ELECTRICAL POWER IS REQUIRED. B. COORDINATE AS NECESSARY WITH OTHER TRADES AND SUPPLIERS TO VERIFY TYPES, NUMBERS ANO LOCATIONS OF EQUIPMENT. 3.5 INSTALLATION OF CONDUCTORS A. UNLESS OTHERWISE SHOWN ON THE DRAWINGS, USE NO. 12 TYPE THWH/THHN CONDUCTORS FOR ALL BRANCH CIRCUITS, PROTECTED BY 20 AMP CIRCUIT BREAKERS. WHERE SO INDICATED ON THE DRAWINGS, USE LARGER WIRES TO LIMIT VOLTAGE DROPS. B. USE IDENTIFIED (WHITE) NEUTRALS ANO COLOR CODED PHASE WIRES FOR ALL BRANCH CIRCUIT WIRING. C. D. 1. MAKE SPLICES ELECTRICALLY ANO MECHANICALLY SECURE WITH PRESSURE TYPE CONNECTORS, OR BY SOLDERING. 2. A. B. FOR WIRES SIZE 6 AWG ANO SMALLER, PROVIDE "SCOTCH-LOCK" CONNECTORS. FOR WIRE SIZE 4 AWG ANO LARGER, PROVIDE BURNOY 'VERSITAPS" ANO HEAVY DUTY CONNECTORS, OR T&B "LOCK-TITE" CONNECTORS. INSULATE SPLICES WITH A MINIMUM OF lWO HALF-LAPPED LAYERS OF SCOTCH BRANCH NO. 22 VINYL-PLASTIC ELECTRICAL TAPE WHERE INSULATION IS REQUIRED. TAPE ALL JOINTS WITH RUBBER TAPE 1 1/2 TIMES THE THICKNESS OF THE CONDUCTOR INSULATION, THEN COVER WITH THE FRICTION TAPE OR THE VINYL- PLASTIC ELECTRICAL TAPE SPECIFlED ABOVE. THE DRAWINGS INDICATE THE GENERAL DIRECTION OF HOME RUNS. CONTINUE ALL SUCH HOME RUNS TO THE PANEL AS THOUGH THE ROUTES WHERE SHOWN COMPLETELY. 3.6 PORTABLE POWER ANALYlER A. PROVIDE PMI POWER QUALITY RECORDER 'EAGLE PQ KIT' (NO SUBSTITUTIONS). "AS-BUILT" 5/lq/tt7 DATE WARNING EXP. -dJdtt 0 1/2 1· '1==:E::E:::==:l" IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE. REVIEWED BY: c.,q.10 DATE B. PROVIDE THE FOLLOWING ACCESSORIES: 1. EAGLE 440 SCANNER 2. FCT-4/48 ULTRA SLIM FLEX CT'S (48" LEADS) 3. CARRYING CASE 4. PRO VISION ANALYTICAL SOFTWARE 3. 7 MCC MODIFICATIONS A. ADO NEW TVSS BUCKET WITH DRY CONTACT (SQUARE D PART #MCC41MA16) TO MCC UNIT 2A. THE DISTRICT WITH PROVIDE CONNECTION BETWEEN TVSS DRY CONTACT ANO TELEMETRY. PROVIDE CUSTOM ENGRAVING WITH EQUIPMENT NAME. MATCH EXISTING ENGRAVINGS. 3.8 TESTING AND INSPECTION A. PROVIDE PERSONNEL ANO EQUIPMENT, MAKE REQUIRED TESTS, ANO SECURE REQUIRED APPROVALS FROM THE OWNER AND GOVERNMENTAL AGENCIES HAVING JURISDICTION. B. MAKE ADVANCE WRITTEN NOTICE TO THE OWNER ADEQUATELY IN ADVANCE OF EACH OF THE FOLLOWING STAGES OF CONSTRUCTION: C. 1. IN THE UNDERGROUND CONDITION PRIOR TO PLACING CONCRETE FLOOR SLAB, WHEN ALL ASSOCIATED ELECTRICAL WORK IS IN PLACE. 2. WHEN ALL ROUGH-IN IS COMPLETE, BUT NOT COVERED. 3. AT COMPLETION OF THE WORK OF THIS SECTION. WHEN MATERIAL ANO/OR WORKMANSHIP JS FOUND TO NOT COMPLY WITH THE SPECIFIED REQUIREMENTS, WITHIN THREE DAYS AFTER RECEIPT OF NOTICE OF SUCH NON-COMPLIANCE, REMOVE THE NON-COMPLYING ITEMS FROM THE JOB SITE ANO REPLACE THEM WITH ITEMS COMPLYING WITH THE SPECIFIED REQUIREMENTS, ALL AT NO ADDITIONAL COST TO THE OWNER. 0. IN THE OWNER'S PRESENCE: 1. TEST ALL PARTS OF THE ELECTRICAL SYSTEM ANO PROVE THAT ALL SUCH ITEMS PROVIDED UNDER THIS SECTION FUNCTION ELECTRICALLY IN THE REQUIRED MANNER. IMMEDIATELY SUBMIT TO THE OWNER A REPORT OF MAXIMUM AND MINIMUM VOLTAGES. ALSO, MEASURE VOLTAGES BETWEEN PHASES AND BETWEEN PHASE WIRES AND NEUTRALS, ANO REPORT THESE VOLTAGES TO THE OWNER. 3. 9 PROJECT COMPLETION A. UPON COMPLETION OF THE WORK OF THIS SECTION, THOROUGHLY CLEAN ALL EXPOSED PORTIONS OF THE ELECTRICAL INSTALLATION, REMOVING ALL TRACES OF SOIL. LABELS, GREASE, OIL AND OTHER FOREIGN MATERIAL, ANO USING ONLY THE TYPE CLEANER RECOMMENDED BY THE MANUFACTURER OF THE ITEM BEING CLEANED. THOROUGHLY INDOCTRINATE THE OWNER'S OPERATION AND MAINTENANCE PERSONNEL IN THE CONTENTS OF THE OPERATIONS ANO MAINTENANCE MANUAL REQUIRED TO BE SUBMITTED UNDER THESE SPECIFlCATIONS. ON THE FIRST DAY THE FACILITY IS IN OPERATION, FOR AT LEAST EIGHT HOURS AT A TIME DIRECTED BY THE OWNER, PROVIDE A QUALIFlEO FOREMAN ANO CREW TO PERFORM SUCH ELECTRICAL WORK AS MAY BE REQUIRED BY THE OWNER. •••ENO OF SECTION••• fSHml CITY OF CARLSBAD 1-------1--+----------------+--l--+--t------------t l___I_J ENGINEERING DEPARTMENT 1--------+----+---------------1----------+--+--+----------l FOXES LANDING SEWER LIFT STATION UPGRADE SPECIFICATIONS E-6 APPROVED BY: WILYt,M ... -5, PLUMMER 1~/4,n,~~<~~~u~~~·1-,£;;:,_~~==~?~•~~.a:.l...-----~q--<21 l.......-------1--..i.....----------------+---+----+---t---1 DEPUTY CITY ENGINEER PE 28176 EXP. 3-31-10 DATE OWN BY: ••n I PROJECT NO. I DRAWING NO. CHKO BY: .,,JM~_ 3840 461-9 RVWO BY: JMM L. _______ _,~---~ 'I'-,4S 13/JILT DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CllY APPROVAL