HomeMy WebLinkAbout168 SYCAMORE AVE; ; CB150745; PermitCity of Carlsbad 1635 FaradayAv Carlsbad, CA 92008 05-14-2015 Residential Permit Permit No: 0B150745 Building Inspection Request Line (760) 602-2725 Job Address: 168 SYCAMORE AV CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2041210700 Lot #: 0 Applied: 03/11/2015 Valuation: $158,866.00 Constuction Type: 5B Entered By: RMA Occupancy Group: Reference #: Plan Approved: 05/14/2015 # Dwelling Units: 0 Structure Type: Issued: 05/14/2015 Bedrooms: 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: LACK RES-ADD 737 SF FOR MASTER BEDR & BED #3, ADD 433 SF GAR, REMODEL 400 SF OF KITCHEN/BATH, REMOVE 105 OF HABITABLE TO ACCOMODATE NEW GARAGE Applicant: Owner: WORTHING INC, B. A. GLOUCESTER WALK INVESTMENTS L L C STE 0 640 GRAND AV 915 HAVENHURST DR CARLSBAD CA 92008 LA JOLLA CA 92037 760-729-3965 Building Permit $834.33 Meter Size Add'! Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $584.03 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CEO Payoff Fee $0.00 Strong Motion Fee $20.65 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PEE (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD#3 Fee $0.00 PLUMBING TOTAL $161.00 Renewal Fee $0.00 ELECTRICAL TOTAL $45.00 Add'! Renewal Fee $0.00 MECHANICAL TOTAL $93.64 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing lnLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $567.71 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB 1473) Fee $7.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $2,313.36 Total Fees: $2,313.36 Total Payments to Date: $2,313.36 Balance Due: $0.00 ,on 49 4't- FINAL APPRPVAL Inspector:Date: -.I"- . I Clearance: NOTICE: Please take NOTICE that approval of your project includes the"Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have prey4ousty been aiven a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit 05-14-2015 Permit No:SWI5OIIO Job Address: 168 SYCAMORE AV CBAD Permit Type: SWPPP Status: ISSUED Parcel No: 2041210700 Lot #: 0 Applied: 03/1112015 Reference #: NCP15001 Entered By: RMA CB#: CB1 50745 Issued: 05/14/2015 Inspect Area: Project Title: LACK ADDITION & REMODEL Tier: I ADDITION & REMODEL TO 2 BEDROOMS; DEMO & BUILD Priority: L Applicant: Owner: BROOKS DESIGN/WORTHING BROOKS LACK MIKE & PAULA P0 BOX 1041 168 SYCAMORE AV CARLSBAD CA 92008 CARLSBAD CA 92018 760-729-3965 760-729-3965 Emergency Contact: BROOKS WORTHING P0 BOX 1041 CARLSBAD CA 92018 760 473-2406 SWPPP Plan Check $48.00 SWPPP Inspections $58.00 Additional Fees $0.00 TOTAL PERMIT FEES $106.00 Total Fees: $106.00 Total Payments To Date: $106.00 Balance Due: $0.00 FIWAL APPROVAL DATE SIGNATURE THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPIANNING 0 ENGINEERING 0 BUILDING 0 FIRE QHEALfH 0 HAZMATIAPCD 4f City of Building Permit Application Plan Check No. Est. Value 15 1635 Faraday Ave., Carlsbad, CA 92008 Cdisbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date J i ii c ISWPPP www.carlsbadca.gov W1 JOB ADDRESS Ate.. SUITEC/SPACE#/UNIT# APN 2Oç - I2 - 07 - CT/PROJECT # LOT A PHASE # a OF UNITS A BEDROOMS St BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE CCC. GROUP DESCRIPTION OF WORK: Inc'ude Squa-RMA MWlye it— r&e L4v o IO J2 EXISTING USE PROPOSED USE GARAGE (SF) S (SF) DECK S(SF) FIREPLACE IAIRCONDITIONING YES# NOI YES ONO U IFIRESPRINKLERS YES[:]NOD APPLICANT NAME or44 ERTY OWNER NAME (_U-c(cz FADDRESS Prina,v Contact mIII'eA- 4&) ADDRESS /C7X 1 AL 0*1 ___ S tlf4io lk^ CITY STATE ZIPZIP zo CITY STATE ZIP OreI., £-& 42O PHONE FAX PHONE IFAX I I EMAIL AUo41'ir35iJ t141WtCOvY) EMAIL / DESIGN PROFESSIONAL CONTRACTOR BUS NAME ADDRESS ________ ADDRESS o_to* CITY STATE ZIP CITY STATE ZIP Ck I W PHONE Pirdrm FAX PHONE 1O12'7-3%' FAX I10-1V? —O7v,4 EMAIL '2 EMAIL INC- ZD 13A1AiD( uI co.com Ii ISTATELIC. # STATE LIC#- I CLASS CITY BUS. LIC.# , (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Ji have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' c mpensa • as re uired by S ction 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensaon i urance carrier and policy number are: Insurance Co. kak L) trJ( Policy No. 'k)82.4'Zi Expiration Dale i This section need not be completed if the permit is for one hundred dollars ($100) or less. 1:3 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (111,100,000), In addition to the cost of compensation, damages as powl9d for in S ction 3706 of the Labor code, interest and attorney's fees. JK CONTRACTOR SIGNATURE Jt4t4/)(j []AGENT DATE 1 /1 .1 11111 1 11111, 31130 Now thereby affirm that lam exempt from Contractor's License Law for Me following reason. [J I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [] I am exempt under Section _____________Business and Professions Code for this mason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes [:]No I (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address / phone I contractors' license number): twill provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work): PROPERTY OWNER SIGNATURE DAGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? i Yes i No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. g lII1FII1 0 N U F cAl.I I - I hereby affirm that there is construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lenders Address JuIrwv.rII*It a Erg_ IcertifythatI have read the application andstatethatthe above infonnation lscorrectandthetthelnfonniationon the plans isaccurate. I agree to citmplyvAth all Cftyordlnances and State hm relartlog to building construction. I hereby authorize representative of the Cityof Carlsbad to enter upon the above mentioned property for inspection purposes. IALSOAGREETOSAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS MD EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit Is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become nut and old tithe building or work authorized by such permit is not commenced within 180 days from the data 0fsuch permit orif the building workauth bysu rrnti suspendedoraba edat any time a11er the workis commenced for a period 01180 days (Section 106A.4 Uniform Building Code). ..'APPLICANT'S SIGNATURE /"°° DATE Inspection List Permit#: CB150745 Type: RESDNTL RAD LACK RES-ADD 737 SF FOR MASTER BEDR & BED #3, ADD 433 SF GAR, REMO Date Inspection Item 12114/2015 89 Final Combo 12/14/2015 89 Final Combo 12/11/2015 89 Final Combo 12/11/2015 89 Final Combo 11/02/2015 23 Gas/Test/Repairs 10/21/2015 23 Gas/Test/Repairs 08/19/2015 17 Interior Lath/Drywall 08/18/2015 17 Interior Lath/Drywall 08/13/2015 16 Insulation 08/11/2015 84 Rough Combo 07/14/2015 13 Shear Panels/HO's 07/14/2015 15 Roof/Reroof 07/02/2015 33 Service Change/Upgrade 06/05/2015 11 Ftg/Foundation/Piers Inspector Act Comments - RI PD AP - RI PB CA PD AP PD AP PB AP PB CA PB AP PB AP PD AP PD AP PD PA PD AP Tuesday, December 15, 2015 Page 1 of 1 EsGil Corporation In (Partners/lip wit/i government for (Bui(&ng Safety DATE: 05/11/2015 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-0745 PROJECT ADDRESS: 168 Sycamore SET: II O APPLICANT 0 JURIS. 0 PLAN REVIEWER O FILE PROJECT NAME: Lack Residence addition and attached garage. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person LII REMARKS: By: Kurt Culver (DA) Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB U PC 05/04/2015 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Vartnersfiip wit/i government for Mudding Safety DATE: 03/19/2015 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-0745 PROJECT ADDRESS: 168 Sycamore SET:I U .,APPLICANT JURIS. U PLAN REVIEWER U FILE PROJECT NAME: Lack Residence addition and attached garage. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Brooks Worthing Eli EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: B.A. Worthing - /Date contacted: (I (by:'-) Eivi all Telephone Fax In Person LI REMARKS: By: Kurt Culver (DA) EsGil Corporation DGA LJEJDMB El PC Telephone #: (760)729-3965 Email: baworthinginc©yahoo.com Enclosures: 03/12/2015 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 15-0745 03/19/2015 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-0745 JURISDICTION: Carlsbad PROJECT ADDRESS: 168 Sycamore FLOOR AREA: 1065 sq ft STORIES: 1 HEIGHT: 18' REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 03/11/2015 DATE INITIAL PLAN REVIEW COMPLETED: 03/19/2015 DATE PLANS RECEIVED BY ESGIL CORPORATION: 03/12/2015 PLAN REVIEWER: Kurt Culver (DA) FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 15-0745 03/19/2015 . PLANS Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Indicate on the Title Sheet of the plans the name of person responsible for the preparation of the plans. Section R106.1.1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Please revise details and ensure they are correctly referenced on the plans. See callout for detail H/5 on sheet 5 this detail is not provided. Details referencing SSWI and SSW2 sheets, which are not provided. B/5 lead line does not appear to indicate the correct location. Review all and revise as needed. . FIRE PROTECTION Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. Carlsbad 15-0745 03119/2015 Exterior walls and projections shall comply with one of the following tables. Section R302.1. Please review and address the following specific concerns: a) The eaves on the western side of the new addition appear by the site plan to be within 5' of the property line; so they must be detailed tp show a I hour rating. Use this table if the building DOES NOT have an automatic fire sprinkler system. Exterior Wall Element Mm. Fire Rating Mm. Fire Separation Distance (Fire-Resistance Rating) 1-hour on the 2! 2 feet to 5 feet Projections underside (Not Fire Rated) 0 hours 5 feet Use this table if the building DOES have an automatic fire sprinkler system. Exterior Wall Element Nun. Fire Rating Mm. Fire Separation Distance Projections (Fire-Resistance Rating) 1-hour on the underside 2: 2 feet to 3 feet (Not Fire Rated) 0 hours 3 feet . GENERAL RESIDENTIAL REQUIREMENTS Sleeping rooms shall have a window or exterior door for emergency escape. Section R31 0. a) Windows must have an openable area of at least 5.7 square feet, with the minimum openable width 20" and the minimum openable height 24". This applies to the 3046 DH windows in bedroom 2. Carlsbad 15-0745 03/19/2015 8. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in the walls/doors facing or containing bathtubs and showers where the bottom exposed edge of the glazing is less than 60" above the standing surface. Exception: Glazing that is more than 60", measured horizontally, from the water's edge of a bathtub. See the figure below. Show that the awning windows in the bathrooms are either tempered glass or 60" above the standing surface. Bathtub, whirlpool tub 1W It#ii 4. 11¼ Sc Oin. or Section view SG = Safety glazing required Measurements are to exposed glazing EXITS, STAIRWAYS, AND RAILINGS 9. Provide stairway and landing details. Section R311.7. Provide details for both the garage stairs and the entry stairs. Maximum rise is 7-3/4" and minimum run is 10", measured from the nosing projection. Where there is no nosing, the minimum run is 11". Minimum headroom is 6-8". Minimum width is 36". The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Carlsbad 15-0745 03119/2015 10. Handrails (Section R311.7.7): Shall be provided on at least one side of each stairway with four or more risers. Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. The handgrip portion of all handrails shall be not less than 1-% inches nor more than 2 inches in cross-sectional dimension. See Section R311.7.8.3 for alternatives. Handrails projecting from walls shall have at least 11/2 inches between the wall and the handrail. Ends of handrails shall be returned or shall have rounded terminations or bends. 11. Guards (Section R312): Shall be installed along open-sided walking surfaces that are located more than 30" above the floor or grade below. Shall have a height of 4" (may be 34" along the sides of stairs). Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along .the top rail. Table R301.5. . ROOFING 12. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge). Show on the plans the area required and area provided. Section R806.2. 13. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to %" maximum openings. Section R806.1. GARAGE AND CARPORTS 14. The garage shall be separated from the residence and its attic area by not less than 1/2" gypsum board applied to the garage side (at walls). Garages beneath habitable rooms shall be separated by not less than 5/8" Type X gypsum board. Section R302.6. Please show fire separation at garage walls. 15. Show a self-closing, self-latching door, either 1-3/8" solid core or a listed 20 - minute assembly, for openings between garage and dwelling. Section R302.5.1. Carlsbad 15-0745 03/19/2015 . FOUNDATION REQUIREMENTS A soils report will be required for this project. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. The City of Carlsbad exemption for this only applies to additions less than 500 square feet. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). Show foundation bolt size and spacing. Foundation bolt size and spacing for braced walls must be clearly shown on the foundation plan. Section R403.1.6. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. One such opening shall be within 3' of each corner of the building. Section R408.1. FRAMING You have chosen to use the conventional construction bracing provisions outlined in the CRC. Provide documentation to show that the plans comply with the Braced Wall provisions of Section R602.10. Include the following: Documentation to show there are sufficient Braced Wall Lines in the building, per Section R602.10.1.4. Documentation to show there are sufficient Braced Wall Panels in each Braced Wall Line, per Section 602.10.1.2. Be sure to include all length factor adiustments from Section 602.10. Braced wall panels can be offset a maximum of 4'. Braced walls must start at each end of a braced wall line (see east and west exterior walls sheet 4). If this is not possible they must begin within 10 ft and meet the exceptions of R602.10.2.2.1. Specifically you need hold-downs on the west wall and you cannot meet the braced wall provisions on the east wall with all of the windows there. If the above items cannot be provided or if the building does not satisfy the conventional bracing provisions, then provide design calculations from a licensed Engineer or Architect to show compliance. Carlsbad 15-0745 03/19/2015 The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2) a) Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. I) Per Carlsbad policy the enclosed special inspection agreement shall be completed and returned. . PLUMBING An instantaneous water heater is shown on the plans. Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. a) The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California 5B407. . ENERGY CONSERVATION Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2013 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CFI R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." Include all applicable sections of the MF-1 R form with the plans. All hot water piping sized 3/4" or larger is required to be insulated as follows: 1" pipe size or less: 1" thick insulation; larger pipe sizes require I 1/2" thick insulation. Note: In addition, the 1/2" size hot water pipe to the kitchen sink is required to be insulated. ES 150.00)2 Carlsbad 15-0745 03/19/2015 . MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes E3 No i:i The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver (DA) at EsGil Corporation. Thank you. Carlsbad 15-0745 03119/2015 CITY OF CARLSEl BAD SPECIAL INSPECTION AGREEMENT B.45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca .gov In accordance with Chapter 17 of the California Building Code the following must be completed When work being performed requires special Inspection structural observation and construction material testing 'roject/Permit: Project Address: THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER1AUTHORIZED AGENT. Please check if you are Owner-Builder U. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please (First) (Last) Mailing Address: Phone: I am: UProperty Owner UProperty Owner's Agent of Record UArchitect of Record LIEngineer of Record State of California Registration Number Expiration Date:__________________ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections1 structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: Date: CONTRACTOR!S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706) This section must be, completed by the contractor / builder I owner- builder. Contractor's Company Name: Please check if you are Owner-Builder 0. Name: (Please print) (First) Mailing Address:____________________________________ Email: State of California Contractor's License Number:____________ (Last) Phone: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement, of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conforr'nance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the eontractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the cohtractor's) organization to exercise such control. I will provide a final report/letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature: Date: B-45 Page 1 of 1 Rev. 08/11 Carlsbad 15-0745 03/19/2015 (DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-0745 PREPARED BY: Kurt Culver (DA) DATE: 03/19/2015 BUILDING ADDRESS: 168 Sycamore BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Remodel 400 68.98 27,592 Addition 737 157.88 116,358 Garage 433 34.45 14,917 Air Conditioning Fire Sprinklers TOTAL VALUE 158,866 Jurisdiction Code 1CB IBY Ordinance Bldg. Permit Fee by Ordinance I $835.511 Plan Check Fee by Ordinance j I $543.08 I Type of Review: El Complete Review El Structural Only El Repetitive Fee El Other Repeats El Hourly EsG1I Fee Hr. @ * I $467.89 Comments In addition to the above fee, an additional fee of $43 00 is due (1/2 hour@ $86/hr.) for the CaiGreen review. Sheet I of I macvalue.doc + 4 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 03-23-2015 PROJECT NAME: LACK RESIDENCE ADDITION/REMODEL PROJECT ID: CB15-0745 PLAN CHECK NO: 11 SET#: 1 ADDRESS: 168 SYCAMOREAVE APN: 204-121-07-00 VALUATION: $158,866 This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: CG 3/23/15 A Final Inspection by the Division is required Yes / No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: BAWORTHINGINC@YAHOO.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 76"02-2750 .760-602-4665 .. Chris Sexton Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carIsbadca.gov Christoøher.GIassen@carIsbadca.ov Greorv.Rvan@carIsbadca.ov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carIsbadca.pv Linda.Ontiveros@cprlsbpdca.gov Cvnthia.Won@carIsbadca.ov Dominic Fieri 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: BM 4 . BUILDING PLANCHECK Development Services CITY 0 F CHECKLIST Land Development Engineering 1635 Faraday Avenue 760-602-2750 CARLSDIAD QUICK-CHECK/APPROVAL www.carlsbadca.gov ENGINEERING Plan Check for CBI 5-0745 Project Address: 168 SYCAMORE AVE Project Description: REMODEL/ADDITION SWI5-1O1 ENGINEERING Contact: CHRIS GLASSEN Phone: 760-602-2784 fl RESIDENTIAL INTERIOR U RESIDENTIAL ADDITION MINOR (<$20,000.00) El] CARLSBAD PREMIER OUTLETS Date: 03-23-2015 APN: 2041210700 Valuation: $158,866 Email: Christopher.Glassen@carlsbadca.gov Fax: 760-602-1052 E TENANT IMPROVEMENT [] PLAZA CAMINO REAL El COMPLETE OFFICE BUILDING 1.4 OTHER: REMODEL/ADDITION OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: CG 3/23/15 DATE:03-23-2015 REMARKS: IF C.D.P. IS REQUIRED, A RESUBMITTLE TO BUILDING DEPARTMENT WILL NEED TO BE RE-ROUTED AFTER CDP IS APPROVED TO ENSURE ANY POSSIBLE ENGINEERING CONDITIONS ARE MET. Notification of Engineering APPROVAL has been sent to BAWORTHINGINC@YAHOO.COM via EMAIL on 03-23-2015 E-36 Page 1 of 1 REV 4/30/11 74 hAo bee& 4 4 4 204-121-0700 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: 03-23-2015 GEO DATA: LFMZ: I B&T: Address: 168 SYCAMORE AVE Bldg. Permit#: CBI5-0745 Fees Update by: Date: 03-23-2015 Fees Update by: Date: 03-23-20J EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: AOl CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units . ADT's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: FEES REQUIRED: Within CFD: DYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) 0 NO 1. PARK-IN-LIEU FEE:DNW QUADRANT ONE QUADRANT OSE QUADARANT []SW QUADRANT ADT'S/UNITS: X FEE/ADT: I LI 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: I X FEE/ADT: I 4 El I I BRIDGE & THOROUGHFARE FEE: EJ DIST. #1 DDIST.#2 DDIST.#3 ADT'S/UNITS: FEE/ADT: FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: X FEE/SQ.FT./UNIT: E SEWER FEE EDU's X FEE/EDU: BENEFIT AREA: EDU's X FEE/EDU: I LI DRAINAGE FEES: b M PLDA: EJHIGH 1MEDIUM JLOW ACRES: .13 X FEE/AC: $4367 $ 567.71 III POTABLE WATER FEES: UNITS I CODE I CONN. FEE I METER FEE SDCWA FEE I TOTAL STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES For City Use Only CITY OF CARLSBAD STANDARD TIER I SWPPP Approved By: Date: PROJECT INFORMATION Site Address: i(DI Assessor's Parcel Number: "21$+ - 5 UDLSO 1)0 Project ID: Construction Permit No.: 28 1'507L1 LS Estimated Construction Start Date (7 Project Duration _______ Months Emergency Contact: Name: 24 hour Phone: '74)O 4-7' 24L:(, Perceived Threat to Storm Water Quality 0 Medium Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs CITY OF CARLSD/-%D13 STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE CERTIFICATE I My project is not in a category of permit types exempt from the Construction SWPPP requirements I My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) I My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to I vertical; and/or disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or ' construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT-ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. E-29 Page 1 of 3 REV 4/30/10 Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs BMPs Management BMPs Pollution Control BMPs 0 0 a, c 0 a, C 0 .E 0 CL E C a, c BestManagementPractke.0 a, (BNlP) Description -) g . - -1 W cc .2 - -2 i .ca a, .22 .i0$o i • CC Ca 2 5 o W co U) U) 0 0 co> ci cQ. co. u o aC >c c COcnc. co x o: CASQA Designation + 9) — C') (9 Cc) CO -- ' C? C? Cl C? 1 (9 (9 (9 o W o w C.) w 0 W U) W Cl) W U) W CO W Cl) W U) W Cl) • W U) - Ck - (l) z U) z U) z CI) z Construction Activity W Grading/SoilDisturbance -- Trenching/Excavation Stockpiling Drilling/Boring Concrete/Asphalt Saw cutting Concrete flatwork Paving _Conduit/Pipelnstallation Stucco/MortarWork - Waste Disposal -- -_..--- - — Staging/Lay Down Area - - - - - Equipment Maintenance -- - and Fueling - - - - - - Hazardous Substance -- _Use/Storage -- Dewatering Site Access Across Dirt -- Other (list): --- Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descmbed, pick one or more best management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was checked off and for each of the selected BMPs selected from the list. For Example - If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction Ingress/Egress" column and place an X in the box where the two meet As another example say the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on the list of BMPs, then write in "Cover with Plastic' in the blank column under the heading Erosion Control BMPs. Then place an X in the box where the "Stockpiling" row intersects the new "Cover with Plastic" column. To learn more about what each BMP description means, you may wish to review the BMPReferenceHandout prepared to assist applicants in the selection of appropriate Best Management Practice measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project. E-29 Page 2 of 3 REV 4/30/10 r CITY OF CAR LSBAD PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division APPROVAL 1635 Faraday Avenue (760) 602-4610 P28 www.carIsbadca.ov DATE: 5/4/15 PROJECT NAME: ADDITION PROJECT ID: PLAN CHECK NO: CB150745 SET#: ADDRESS: 168 SYCAMORE AV APN: This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: baworthinginc@yahoo.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov Remarks: Plan Check No. CB150745 Address 168 sycamore av Date 5/4/15 Review #2 Planner GINA RUIZ Phone(760)602-4675 Type of Project & Use: ADDITION Zoning: R-3 General Plan: E!:[ Facilities Management Zone: 1 CFD (in/out) #_Date of participation: Remaining net dev acres:_____ (For non-residential development: Type of land use created by this permit: REVIEW #: 1 2 3 Legend: Item Complete El Item Incomplete - Needs your action Z El El Environmental Review Required: YES El NO 0 TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Z El El Discretionary Action Required: NO Z YES El TYPE: APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: El Z El Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO El CA Coastal Commission Authority? YES Q NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): CALCULATION OF WALLS BEING REMOVED NOT STATED SEE ADDITIONAL COMMENTS ON NEXT PAGE PLANCHECK NO. 2: 36.4% OF EXTERIOR WALLS BEING REMOVED - NO CDP REQ'D AS REMOVAL IS UNDER 50% El El Habitat Management Plan Data Entry Completed? YES El NO If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (AIP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Z El El Inclusionary Housing Fee required: YES El NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES El NO El (AIP/Ds, Activity Maintenance, enter CB#, Housing Y/N, Enter Fee, UPDATE!) toolbar, Screens, Housing Fees, Construct Housing Tracking r Form (form P-20) completed YESEl NOEl N/As P-28 Page 2 of 3 07/11 Site Plan: DD City Council Policy 44 - Neighborhood Architectural Design Guidelines Z LI LI Applicability: YES LI NO 0 0 Project complies: YES LI NOD Zoning: 0 0 LI Setbacks: Front: Required 20 Shown 16' *SEE ADDITIONAL COMMENTS FRONT PORTION OF THE HOUSE BELOW REGARDING THE NON CONFORMING PLANCHECK NO. 2:18' SHOWN — PER STAFF REVIEW, LOT IS INTERIOR LOT AND ONLY REQ'D TO HAVE 15' FY SETBACK Interior Side: Required Shown 5'& 5.75' Street Side: Required N/A Shown NL4 Rear: Required j.Q Shown 11.5' — EXISTING SHED TO BE REMOVED AS STATED ON PLANS Top ofslope: Required Shown N/A Structure separation: Required Shown JL Z LI LI Lot Coverage: Required 60% MAX Shown 41?IQ Z LI LI Height: Required 30' MAX (4:12 Ditch stated) Shown 114. LI Z LI 4. Parking: Spaces Required 20'x 20' INTERIOR DIMENSIONS Shown 18.6'x 20!PLANCHECK NO. 2: 20'X 20' FREE AND CLEAR INTERIOR DIMENSION SHOWN ON PLANS (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown LI Z LI Additional Comments PLANCHECK NO. 1: 41 IN rIDnCD Tr TDRMM I TUC ODt It'T DrI IIDO A (rIAOTAI ICI (DIAI.IT øDIAIT DI AO OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 5/4/15 P-28 Page 3 of 3 07/11 EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORNIA 92071 (619) 258-7901 Fax 258-7902 Mike & Paula Lack May 28, 2015 168 Sycamore Avenue Project No. 15-1106E6 Carlsbad, California 92008 Subject: Foundation Excavation Observation Proposed Residential Addition (Lack Residence) 168 Sycamore Avenue City of Carlsbad, California 92008 References: 1. "Foundation Plan and Details Review, Proposed Residential Addition (Lack Residence), 168 Sycamore Avenue, City of Carlsbad, California 92008", Project No. 15-1106E6, Prepared by East County Soil Consultation and Engineering, Inc., Dated April 24, 2015. 2. "Limited Geotechnical Investigation, Proposed Residential Addition (Lack Residence), 168 Sycamore Avenue, City of Carlsbad, California 92008", Project No. 15-1106E6, Prepared by East County Soil Consultation and Engineering, Inc., Dated April 21, 2015. Dear Mr. & Mrs. Lack: In accordance with your request, we have observed the foundation excavations for the proposed residential addition to the existing single-family residence at the subject site. The footings have been excavated to the proper depth and width into competent bearing soils and are in compliance with the approved building plans. Foundation excavations, soil expansion characteristics and soil bearing capacity are in accordance with the referenced geotechnical report (Reference No. 2). If we can be of further assistance, please do not hesitate to contact our office. Respectfully Submitted, gg co No. GE 2704 Exp: I RCE 54071, GE 2704 MSD/md EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD SUITE I SANTEE CALIFORNIA 92071 619;58-7901 fax 619 258-7902 Mike& Paula Lack 168 Sycamore Avenue Carlsbad, California 92008 Subject: Foundation. Plan and Details. Review Proposed Residential Addition (Lack Residence). 168 Sycamore Avenue City of Carlsbad, California 92008 April 24, 2015 Project 'No. 15-11:06136 Reference: "Limited Geotechnical Investigation, Proposed Residential Addition (Lack Residence), 168 Sycamore Avenue, City of Carlsbad, California 92008", Project No 15-1106E6, Prepared by East County Soil Consultation and Engineering, Inc., Dated April 211% 2015. Dear -Mr. & Mrs. Lack: In accordance with your request; we, have reviewed the foundation plan and details p r e p a r e d b y Brooks Design of Carlsbad, Califorma for the proposed residential addition at the subje c t s i t e The foundation plan and: details were found to be in substantiaf. conformance wit h . the recommendations provided in the referenced geotechrncal report Our firm should obse r v e t h e foundation excavations for proper size and embedment into competent bearing soils If we can be of further assistance, please, do not hesitate to contact our office. Respectfully, submitted, Mamadou SaliouDiallo, P.E. RCE 54071, GE 2704 MSD\ntd Ch 11507445