HomeMy WebLinkAboutDWG 469-8A; CT 05-10; POINSETTIA PROPERTIES The Tides; 01-13I GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSf:DES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF · COND/110NAL APPROVAL, CITY STANDARDS OR OTHER ADD/110NAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCT/ON. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERT/FICA TE OF INSURANCE AS WELL AS ADD/110NAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY . OF CARLSBAD AS AN ADD/110NAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HA VE A RA TING OF "A-• OR BETTER AND A SIZE CATEGORY OF CLASS V OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE. 5. UNLESS EXEMPTED BY SECTION 301.(b}5 OF THE UNIFORM BUILDING CODE, RETAINING WALLS OUTSIDE OF PUBLIC RIGHT OF WAY REQUIRE SEPARATE PERMITS FROM THE BUILDING DEPARTMENT. 6. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE.BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY . ENGINEER, NOTED WITHIN _THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL ORA WINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT COND/110NS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND. OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STA TE OF CALIFORNIA, PR/NC/PALLY DOING BUSINESS IN THE Fl/:LD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED. TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VER/FICA TION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF-THE STA TE OF CALIFORNIA PRING/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIF/CA 1/0NS AND THE " EARTHWORK SPECIF/CATIONS • ATTACHED . TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 14. A PRfCQNSTRl/CTIQN MEETING SHA/ L BE HE/ D i AT THE SI TE PRIOR TO THE BEGINNING OE WORK AND SHAii BE ATTFNDED BY All RfPR£SENTA11VES RESPONSIBLE FOR CONSTRUCT/ON, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK THE CONTRACTOR SHALL REQUEST A PRECONSTRUCTION MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE(5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE AND TIME FOR THE PRECONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. ALL INSPECTION RfQUESTS OTHER THAN FOR PR[CONSTRI/CTION MEE11NG WII I BE MADE BY CA/ UNG THE ENGINEERING 24 HOUR !INSPECTION REQ//fSI I /NE AT {760) 438 3891. INSPECTION REQUEST MUST BE RECEIVED PRIOR TO 2· OD P.M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2: 00 P. M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FDR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDA~DS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR coo¢_ SECTION_ 6705 BY SUBMlmNG A DETAIL PLAN TO THE CITY ENGINEER AND/OR I CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCA VA 1/0N OF SUCH TRENCH OR TRENCHES OR 'DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5; OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCA VA 1/0N. IF 1H£ PLAN VARIES FROM 11-1£ SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS. 11TLE 8 CALIFORNIA ADMINISTRATIVE CODE. THE PLAN SHALL BE PREPARED BY A REGISTERED £NG/NEER AT 1H£ CON1RACTORS £Xf?£NSE. A COPY OF THE OSHA EXCAVA 1/0N PERMIT MUST BE SUBMITTED iTO THE INSPECTOR PRIOR TO EXCAVATION. ; 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPL/CA 1/0N FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF I BLASTING OPERA 710NS. ' 19. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERA110NS WILL CEASE IMMEDIATE/ Y, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERA 1/0NS CONDUCTED ON THE SITE OR l ADJA_ CENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERA 1/0N OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCT/ON EQU/PM NT AND ANY OTHER ASSOC/A TED GRADING EQUIPMENT SHALL BE LIMITED TO THE I PERIOD BETWEEN 7: 00 A.M. AND SUNSET EACH DAY, MONDAY THRU FRIDAY AND ('/0 EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO. 469-BL , AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. WHERE AN EXIS71NG PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERA 710N, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 31. THE CONTRACTOR SHALL VERIFY 1HE LOCA 1/0N OF ALL EXISTING .. FACILITIES ( ABOVE GROUND AND UNDER GROUND ) WITHIN THE PROJECT SITE SUFFICIF::NTL Y AHEAD . OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH . TH£ PROPOSED ~ . ' 32. THE CONTRACTOR SHALL NOTIFY AFFECTED U11LITY COMPANIES (SEE BELOW) AT . LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACIL/TlES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTA Tl.VE. UNDERGROUND SERVICE ALERT (80·0-~422-413_ 3 . SDG&E (BOO 660-7343 AT&T (BOO 892-0123 TIME WARNER CABLE (760)438-7741 COX COMMUN/CATIONS (760)806-9809 CITY OF CARLSBAD(STREETS & STORM DRAIN) (760)434-2980 "CITY OF CARLSBAD(SEWER, WATER & RECLAIMED WATER) (760)438-2722 "SAN DIEGUITO WATER DISTRICT (760)633-2650 •1 • .EUCAOIA WASTEWATER DISTRICT (760)753-0155 *VALLECITOS WATER DISTRICT (760)744-0460 "OL/VENHAIN WATER DISTRICT (760)753-6466 "BUENA SAN/TA TION DISTRICT (760)726-1340 *AS APPROPRIATE 33. PERMIT COMPLIANCE REQUIREMENTS: A. FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO . GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A.BJ CARLSBAD MUNICIPAL CODE. B. PRIOR TO FINAL APPROVAL OF A GRADING PERMIT -THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR {15.16.120 A.10} CARLSBAD MUNICIPAL CODE: (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND /RR/GA TION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS ( OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS. THE REPORT SHALL ALSO /(VCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. (4) REPORT Wl1H AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. 34. UNLESS A GRADING PERMIT FOR 1HIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. . 35. 1HE SOILS REPORT TITLED "PRFLIM/NARY GFOTECHN/CAI INTERPRfTIVF RFPORT PROPOSED 29 LOT RESIDENTIAL DEVELOPMENT LOCATED ON SOUTHWEST CORNER OF POINSETTIA LANE AND LOWDER LANE" PREPARED BY EARTH-STRATA INC. DA TED MAY 11 ,2.01.!l. , SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN. ALL • GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND 'SPECIF/CA )JONS CONTAINED IN SAID SOILS REPORT. 36. IN ACCORDANCE WITH THE CITY SUSMP, ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SA ))SFAC710N OF THE CITY ENGINEER. "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPEC/FICA710NS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: RICK ENGINEERING COMPANY ADDRESS: 5620 FRIARS ROAD CITY, STA TE: SAN DIEGO. CA. TELEPHONE: 619 291-,-070 BY: JOHN D, GODDARD JR. (NAME OF£ R.C.E. N0,:_~33~0~3~7 ___ ,.,_ _ __,.-,------ REGISTRA TION EXP/RATION DA TE: _...;0.,6"'-/,-"'J0"'/'-'1=-2~--- SOILS ENGINEER'S CERTIFICATE DATE:· -{ezft/ --I 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, Al'/D WASTE MATERIAL SHALL BE I, CHAD E. WELKE , A REGISTERED (CIVIL/ DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. 11-1£ CON1RACTOR GEO TECHNICAL) ENGINEER OF THE STATE OF CALIFORNIA, PRING/PALLY DOING SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERA710N. A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE ARlA TO BE GRADED. NO TREES ARE SITE WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DA TES OF TO BE REMOVED UNLESS. S:!;?~IC(ILLY NOTED ON r11E PLAN. ~~~~ '1EsAPJ<).L 14.iE so1Ls2~kioRTA~MPILED A;~~ 16THIS siu8~10WITH T:1$ 24. ALL AREAS S.HALL_ B_ E_GRADED_-_· TO D/'!AIN. GRADING, RESULTING IN THE PONDING OF ,. c.O ~'-ENDATIONS HAS BEEN SUB~MITT TO TH%:---.IJ FIG£ Of". THE CITY WAlER IS NO.T PERMITTED.-_/ILL EARTHEN SWALES AND DITCHES SHALL HAVE A , ,/.:I~,;,"-.,-. "'r:I ., ' · / _.,,..-,,...-/ ~_;;7 MINIMUM ONE-PERCENT .SL.OPE;:'· · · .. , ,ff' S) E. <'N, • • \ SIGNED· p' -~ ~ ' 25. THESE PL~NSl<RE·SUBjECT TO A S/Cif,/ED AND APPROVED SET OF EROSION_ ff, ~'I'-:(,~ ., L . ' 6 ~7 ;/... • . CONTROL PLANS_' EROS/Of,/ CON. 7ROL SHA~l,,.~BE AS: SHOWN AND AS APPROVED B ,if.I_ G.E./P.E. NO.: ~2=3~7=8-~-""-'a?.~~~...£~---,---- THE CITY ENG/N_EER OR AS D/Rf:CTED BY '(/:/'PROJECT INSPECTOR. ; ·ii; . NO.C(ll}li2 . ~:0• ·: ioATE: "1-t'f-tf . c ··· 26. ALL SLOPES SHALL Bf JRIMl,IED TO A Fl' SH G~ADE TO PRODUCE A UNIFOf( * ·XP. ~0./.. ... -#';{~ c,\ • q J 1..-ill-t-z_ SURFACE AND. CROSS SECTl()N. THE SI SHA~L BE LEFT IN A NEAT AN •. ._}_:LICENSE EXPIRATION DATE: ,-_O_-~(l--__ ~--,-c-= ORDERLY CONDITIGN. · ALL .STQNES, ROOTS OR OTf-lER DEBRIS SHALL BE REMOVED • AND DISPOSED OF AJ A-S/Tf APPROVED ·or BY THE CITY ENGINEER. 27. ALL SLOPES S:HALC-1·:aE . i#R,[<,ATED.C STABILIZED, PLANTED AND/OR HYDROSEEDED """~~ s CERTIFICATE WITHIN TEN (10) DAYS OrTHE'f:·TlME WHEN EACH ! SLOPE IS BROUGHT TO GRADE I ( WE ) HEREBY CERTIFY THAT A AS SHOWN ON THE APPROVED GRADING PLANS. GEOLOGIST HAS BEEN OR WILL BE GRADING ACT/VI ON REGISTERED SOILS ENGINEER OR RETAINED TO SUPERVISE OVER-ALL COMPACTION AND STABILITY OF THIS SITE. r 5620 FRIARS ROAD :!° SAN DIEGO, CA 92110 J-14826C S·ll•t (PR NT NAME BELO LINE) DATE 619.291.0707 ~ (FAX)619.291.4165 ~ ENGINEERINGCOMPANY _________ .., __ oi'iii''iiikeiii,g!i!iiiii"••••';,;;'";.•;;;·';;;;;"m 9 San Diego Riverside -Orange• San Luis Obispo -Bakers,fleld • Sacramento -Phoenix -Tucson R, \ 14826\0rndln,;i\l 482lLQr'd_OI. dsin \ \sr~ _,-I b1 \ R I ck stmdards\Bent I ey_200 6\wo,-kspoce\pr-o J eots \CcrpStds_2005_SD\ Ip I ot\CorpS tds_2005_ SO. pen 11-f.lAR-2011 09,16 Ut.l\41 ~-fl\,\W ::3,. .. CITY OF OCEANSIDE 7. ... '2, ))9 I ~ Iii <:' CITY OF VISTA 0-{) PACIFIC OCEAN AVE CITY OF ENCINITAS VICINITY MAP NOT TO SCALE LEGAL DESCRIPTION ITY OF N MARCOS LOT 171, OF CARLSBAD TRACT NO. 73-24, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STA TE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 7996, FILLED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, AUGUST 2, 1974 SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN HEREON IS BASED UPON A FIELD SURVEY PERFORMED BY RICK ENGINEERING CO, ON APRIL 29. 2010. TOPOGRAPHY SHOWN HEREON CONFORMS TO NA 1/0NAL MAP ACCURACY STANDARDS. PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) 214-471-53 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 1982667 E 62.37480 BENCH MARK DESCRIPTION: CITY OF CARLSBAD BENCHMARK CLSB-049 LOCATION: THE BENCHMARK FOR THIS SURVEY IS THE 2-1/2" BRASS DISK STAMPED "CLSB-108" IN TOP OF CURB LOCATED AT THE SOUTHWEST CORNER OF BA TIQU/TOS DR. AND LAUREL WOOD STREET PER RECORD OF SURVEY NO. 17271. RECORDED: __ F:_EB_R_U_A_R_Y_0-'-'8,c...2::..0c..:0.:::2 _________ _ ELEVATION: -~1~60~.4=2~------DATUM: NGV029 REFERENCE DRAWINGS ROUGH GRADING PLAN LOT 171. CARLSBAD TRACT NO. 73-24 IMPROVEMENT PLANS FOR CWRF PIPELINE TO •o• TANKS REACHES 1 & 3 PLANS & PROFILES FOR S1REET, SEWER, WATER & DRAINAGE IMPROVEMENTS IN CARLSBAD TRACT NO 73-24 PLOT & GRADING PLAN CARLSBAD TRACT NO. 73-24 EARTHWORK QUANTITIES CUT: 5200 CY FILL: 19200 CY IMPORT: 11:,000 CY EXPORT: 0 CY REMEDIAL: 42100 CY owe. 216-4 DWG. 403-18 DWG. 175-9 DWG. 175-9A NOT TO SCALE ··WORK TO BE DONE THE. GR_ AD/NG WORK SHALL CONSIS_ T OF THE CONSTRUCT/ON OF Al.,L CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES_, EROSION CONTROL FACILITIES, AND PLAN71NG OF PERMANENT LA/VDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTSU ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIF}CA 710N$, . REQUIREMENTS, RESOL 710NS AND ORDINANCES CITED ON THESE PLANS. THE GRADING '-'!'(ORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE 71ME OF CONSTRUCTION>-As DIRECTED BY THE CITY ENGINEER . · 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS , _ 3. THIS SET OF PLANS 4. RESOLUTION NO. 6095-6099 DATED: MAY 17, 2006 5. THE STANDARD SPECIF/CA 710NS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK.) 6. SOILS REPORT AND RECOMMENDA710NS BY . EARTH-STRATA INC. DATED: 05/11/2010 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _ __i:,µ:L_ ______ ~ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED REFER TO M/TlGAlED NEGATIVE DECORATION DATED: MAY 17, 2006 10. STORM WATER POLLU710N PREVEN710N PLAN PREPARED BY RICK ENGINEERING DA TED SEPTEMBER 2010 WDID NO. 937C359990 11. STORM WATER MANAGEMENT PLAN PREPARED BY RICK ENGINEERING DATED NOVEMBER 03. 2010 , 12. CALIFORNIA STORM WATER QUALITY ASSOC/A TION BMP CONSTRUCTION HANDBOOK AND CAL TRANS CONSTRUCTION SITE BMP MANUAL. / DESCRIPTION LEGEND DWG.NO. SYMBOL QUANTITY PROJECT BOUNDARY--------------------------- - LOT LINES-------------------------------- PROPOSED SLOPE (2: 1 MAX. CUT)--;----------------V V PROPOSED SLOPE (2, 1 MAX. FILLJ------------------[,V,; i,: w,·· EXISTING SLOPE-----------------------·~ EXISTING CONTOUR----------------------.-,.-··350 ·- FINISH CONTOUR ------ - ---------------- FINISH ELEVATION (FS=FINISH SURFACE, FG=FINISH GRADE, TC=TOP OF CURB)---~ DAYLIGHT LINE-------- - -------- - - - ---- TOP/TOE OF SLOPE----------------------· - LOT NUMBER - - ------- ---------------· · FINISH PAD ELEVATION---------------------·· - CONCRETE BROW OITCH---------TYPE B & D, SDRSD D-75• ----· · STORM DRAIN PIPE (EXISTING)------------------- _350- FG 3502_ ... C -11---~l-f 75 (119.8) c:::::> c:::::> --5 70 L F ---5D -- STORM DRAIN STRUCTURE !EXISTING)-----------------~ rn::~g~ = ~;1 L~!.• PROPOSED STORM DRAIN (PRIMARY SYSTEM! (PVT,J-------------::-----\=Eo[f==:;==----24"RCP -191 L.F. PROPOSED TYPE "8" CLEANOUT (PVT,) ------SDRSD D-10------- PROPOSi:D TYPE "A-4" CLEANOUT (PVT.l---·--SDRSD D-9-------- PROPOSED TYPE "8" CURB INLET (PVT. l -; ti -•-SDRSD D-2• - - - - - - - · PROPOSED TYPE "B-1" CURB INLET (PVT. l -4 '' - -SDRSD D-2• - - - - - - - · PROPOSED ATRIUM GRATE---------SEE DETAIL SHT. 3------ BAYSEPARATOR FS 4X4 ---------SEE DETAIL SHT. 3------ @I ------4 EA. @I ------7 EA. Q ------6 EA. Cb-----6 EA. ® ------1 EA. ~---1EA. STORMTRAP (MODEL NO. 5'-0" SINGLETRAP)---SEE DETAI~ SHTS. 7,8,9----· a------1i:A. 1 PROPOSED RETAINING WALL-------------------- PROPOSED SOUND WALL-· --------(PER LANDSCAPE PLANS)-----· PROPOSED 4"PVC PERFORATED DRAIN !PVT,)--------------- ----4,038 SF ----1,100 L.F. --------66 L.F. • MODIFIED PER CITY STANDARDS NOTE: ALL WORK PROPOSED, INCLUDING STORM DRAIN AND STORM WATER TREATMENT FACILITIES. ARE PRIVATE UNLESS OTHERWISE NOTED. SHEET INDEX SHEET 1 & 2 -----------71TLE SHEET & NOTES SHEET 3 --------------DETAILS & BAYSEPARATOR DETAIL SHEET 4-6 ------------GRADING PLANS SHEET 7-9 ________ _::. ___ STORMTRAP DETAILS SHEET 10 -------------WALL DETAILS SHEET 11-13 -----------STRUCTURAL PLANS ,\tJl) ,~ e,Aset> ""1 ~ 'IISU/!'l Fl64) C/16::(c. oNt.y . . / ENGINEER OF WORK ~Ip E\GINEERING CO. ~;)~ .ti J/JJJ1v (~ JI HN D.\,i;ODDARD, JR. R.C.~. 1'.3~37 . DATE ,. ~PLANNINGDEPARTMENTP:PPROVAL \ ~ '>f/::-"AS B.UIL T" & zt,, DATE: t../ ;13;!/ \ \ ~• ,L (SIGNED> fE .() ~~ /--/0,l7_ <'.'.>an lo.le <.t PLANNING DIRECTOR · . 6tl I L \ I ' C.E. ,3.3.Q37 EXP. G/?,0/ 14 DATE -~\~l?i,\r-DATE: O'\ /11../ \I ·., ...... \ NOTE: GRADING QUANTITIES ARE EST/MA TED 'FOR PERMIT PURPOSES ONLY AND ARE NOT ' i~.~~~f'i.j 70 BE USED FOR FINAL PAY QUANTITIES. v·' G ED) REV9E.JQ.. B, _;' 4,J,-3--S•flf RECOMMENDED BY: C.n(\6 J1'iz.v \Ne?.il"Mu\.Y\ &~ ~Ar~i Jfbf/#f'1 (PRINT NAME) INSPECTOR DATE f----f----+-----~-----f-----1---+---+----l I SHE1ET I ~C_IT~Y=O=F~C=A~R~L=S=B~A~D ~'f_H1E~ET~S _ ENGINEERING DEPARTMENT _ u j ' >-----1>-----+-----------------+----1>-----+----+----1 GRADING PLANS FOR: . ,_;,....a--------RE_O_UI-RE_D_T_R-EA-TM_E_N_T -C-ON-T-RO_L_B_M_P '-IT-AB-LE---~~~ POINSETTIA PROPERTIES -TYPE DESCRIPTION OWNERSHIP MAINTENANCE SHEET NO. MAINTENANCE (THE TIDE s) t-------+-,----==="""cc---t-----1-,--=A=GR=E=EM=E~N~T-,--+-__ --1f-----F~R=EO~U=E~NC~Y-1---+---+-----------------+----+---+----1---< TITLE SHEET V OS-OVPUD OS·OO/COP 05.2 UNDERGROUND RECORDED CITY STORMTRAP BAYSAVER BIO-RETENTION DETENTION BASIN PVT AGREEMENT 3, 4• 7, 8• g AS NEEDED APP_R. o_ v __ ED, , ,111_ •. --./ ~ J,-... · .. -.'_(l __ . J GLEN .K, _YAN. PESKI BAYSEPARATOR FS RECORDED CITY . ,/, /4'//Jff._J<?J}/th-, }f~· ,·«; J.ft,FJI _ 4x4 LOW FLOW SYSTEM PVT AGREEMENT . 3, 4 AS NEEDED ., . . SENIOR CIVIL ENGINEER 'PE 41204 EXPIRES 3/31/13 ' DATE RECEIVES DISCHARGE FROM STORM TRAP PVT RECORDED CITY I\ AS-BU/Lr AGREEMENT 3,4 AS NEEDED DATE INITIAL OWN BY: REC PROJECT NO. DRAl'IING NO. CT 05-10 PROJECT'S PRECEIVED THREAT HIGH ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKD BY: Q!'.ll,.. RVWD BY: 469-8A I I l I ,. n[ '1911 VJ' i • I I Q ~ SPECIAL NOTES THE FOLLOWING NOTES ARE PROVIDED TO GIVE DIRECTIONS TO THE CONTRACTOR BY THE ENGINEER OF WORK, THE CITY ENGINEER'S SIGNATURE ON THESE PLANS DOES NOT CONSTITUTE APPROVAL OF ANY OF THESE NOTES AND THE CITY WILL NOT BE RESPONSIBLE FOR THEIR ENFORCEMENT. 1. NEITHER THE OWNER, NOR THE ENGINEER OF WORK WILL ENFORCE SAFETY MEASURES OR REGULATIONS, THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE ANO FEDERAL SAFETY AND HEAL TH STANDARDS, LAWS AND REGULATIONS. 2. THE CONTRACTOR AGREES THAT HE ~HALL ASSUME SOLE ANO COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS ANO PROPERTY,ANO THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE UMITEO TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ALL GRADING IS DONE AND STORM DRAINS ARE BUil T IN ACCORDANCE WITH THESE PLANS. IF THERE ARE ANY QUESTIONS REGARDING THESE PLANS OR FIELD STAKES, THE CONTRACTOR SHALL REQUEST AN INTERPRETATION BEFORE DOING ANY WORK BY CALLING THE ENGINEER OF WORK AT (619) 291-0707. THE CONTRACTOR SHALL ALSO TAKE THE NECESSARY STEPS TO PROTECT THE PROJECT AND ADJACENT PROPERTY FROM ANY EROSION ANO SILTATION THAT MAY RESULT FROM HIS OPERATIONS BY APPROPRIATE MEANS (SANO BAGS, HAY BALES, TEMPORARY OESIL TING BASINS, DIKES, SHORING, ETC.), UNTIL SUCH TIME ' THAT THE PROJECT IS COMPLETED ANO ACCEPTED FOR MAINTENANCE BY WHATEVER OWNER, AGENCY OR ASSOCIATION IS TO BE ULTIMATELY RESPONSIBLE FOR MAINTENANCE. . I 4. THE LOCATION AND ELEVATION OF EXISTING I¥PROVEMENTS TO BE MET BY WORK TO BE DONE SHALL BE CONFIRl,.ED BY FIELD MEASUREMENTS PRIOR TOl CONSTRUCTION OF NEW WORK. ! 5. DURING CONSTRUCTION, THE CONTRACT9R SHALL PROPERLY GRADE ALL EXCAVAT D SURF ACES TO PROVIDE POSITIVE DRAINAGE AND PREVENT PONDING OF WATER. HE SHALL CONTROL SURFACE WATER TO IAVOIO DAMApE TO ADJOINING PROPERTIES OR TO FINISHED WORK ON THE SITE, THE CONTRACTOR SHALL TAKE REMEDIAL TO PREVENT EROSION OF FRESHLY GRADED AREAS AND UNTIL SUCH TIME AS PERMANENT DRAINAGE AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 6. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS REQUIRED TO PROTECT ADJACENT PROPERTIES DURING THE GRADING OPERATIONS. 7. THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF WORK, PRIOR TO THE PROJECT C(_OSE-OUT, A SET OF AS-BUILT PLANS oqcuMENTING ANY CHANGES MADE DURING CONSTRUCTION. ; ' 8, BEDDING, SUITABLE MATERIAL SHALL BE CLASS I OR II. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" FOR 4"-24'~ 6" FOR 30"-60", EROSION CONTROL NOTES 1. IN CASE EMERGENCY WORK IS REQUIRED,CONT ACT DARREN BOLTON (909)937-3270 (PHONE NUMBER) AT 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. 3. DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL, 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6, THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE ENO OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (401/.l. SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/ 4 INCH MINIMUM AGGREGRATE. 11. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (901/. COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF THE EROSION ANO SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, ST ATE OF CALIFORNIA. TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIFICATIONS AND THE FOLLOWING, A. HYDROSEEDING SHALL BE APPLIED TO, 1, ALL SLOPES THAT ARE GRADED 6,1 (HORIZONTAL TO VERTICAU OR STEEPER WHEN THEY ARE, a: THREE FEET OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED FLATTER THAN 611 WHEN ANY OF THE FOLLOWING CONDITIONS EXIST, a. NOT SCHEDULED FOR IMPROVEMENTS(CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREATION DIRECTOR AS HIGHLY VISIBLE TO THE PUBLIC. c. HAVE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREATMENT. RICK 5620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 (FAX)619.291.4165 J-14826C ricken lneering,com @ San.Diego Riv·erside·. Orange -Sari Luis Obispo --·eakersfteld -Sacramento - P oenlx-Tuc5on R• \ I 4326\.Gradlng\ I ~826.grd_02. d<;1n \ \srv_r lbl \RI cl<Standards\B()nt !ay_2006\,.o..-l<apQca\p..-a Jaota\Co..-pStds .. 2005_$0\ Ip lot\CorpStda.2005_$Q. i:,en :_;-f,:~\-C'.11; ')~•IS - ----. '·.· . ,. - . -,, ' B. HYOROSEEDED AREAS SHALL BE IRRIGATED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, 1. ALL SLOPES THAT ARE GRADED 6,1 OR STEEPER AtjD THAT ARE, a. THREE TO EIGHT FEET IN HEIGHT SHALL BE IRRIGATED BY HAND WATERING FROM QUICK COUPLERS/HOSE BIBS OR A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 1001/. COVERAGE. b, GREATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A CONVENTION- AL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 1001/. COVERAGE. 2. AREAS SLOPED LESS THAN 611 SHALL BE IRRIGATED AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEDING. THE DEVELOPER SHALL SUBMIT A PROPOSED SCHEME TO PROVIDE IRRIGATION TO THE CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPES ANO COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM. 3. IRRIGATION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM LEVEL FOR THE GROWTH OF THE HYDROSEEDED GROWTH. c. HYo~o\EEFfciN~I~1~H~~tL~0~~~~sbF o~0 AttsiF Ti1~/0LLOWING, a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs.PER ACRE OF ZORRO FESCUE c. 3 lbs. PER ACRE OF E SCHOOL CIA CALIFORNICA d. 4 lbs. PER ACRE OF ACHILLEA MILLEFOLIA e. 3 lbs. PER ACRE OF AL YSSUM (CARPET OF SNOW) f. 1/2 lb, PER ACRE OF DIMORPHOLECA g. ITEMS c,d,e, ANO f OF THIS SUBSECTION MAY BE OMITTED ON LOCATIONS WHERE THE AREA BEING HYDROSEEDED IS NOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCASTING BEFORE HYDROSEEOING. I. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBSITE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE CERTIFICATION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. J. NON-PHYTO-TOXIC WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR. 2. TYPE 1 MULCH APPLIED AT THE RATE OF NO LESS THAN 2000 lbs PER ACRE. TYPE 6 MULCH (STRAW) MAY BE SUBSTITUTED, ALL OR PART, FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHEN STRAW IS USED IT MUST BE ANCHORED TO THE SLOPE BY MECHANICALLY PUNCHING NO LESS THAN 501/. OF THE STRAW INTO THE SOIL. 3, FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFATE, 16-20-0, WITH 151/. SULPHUR APPLIED AT THE RATE OF 500 lbs. PER ACRE. D. AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEEDING BY, 1, ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A COMBINATION OF, a. TRACK WALKING SLOPES STEEPER THAN 611 b, HARROWING AREAS 6,1 OR FLATTER THAT ARE SUFFICIENTLY FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE. 2. CONDITIONING THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED. b. THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING OR COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR GROWTH. E. HYDROSEEDED AREAS SHALL BE MAINT AINEO TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE. HYDROSEEDING IS THE f'ERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED ANO ALL BONDS RELEASED. NORTH If. 53' (COMMON LOT I GENERAL UTILITY AND ACCESS EASEMENT SOUTH If. 10.5' 10.5' B' 12' PARKING BAY 4' 10' 2% - ;: ' :,:,:· ~ I-- 11' z 12' 2o/. -7' z LEGEND IMPROVEMENT SHEETS LIMIT AND NO. ---- ,--7 [B) __ J PROJECT BOUNDARY --------- PROPOSED STORM DRAIN ------- EXISTING PROPERTY LINES ------- ---------- EXISTING WATER ---------- EXISTING RECLAIMED WATER------ EXISTING SEWER ---------- EXISTING STORM DRAIN -------- -----W---- ----RW---- -----s---- ----SD---- CURB LINE ARI .5' TO 10.0' 2.5' 21/, - ELEVATIONS \ER PL·AN If. VARIES FRONT OF GARAGE 5' VERTICAL CURVE• • C_-'..F,,_.F~, -~~I 5' MIN. PAO GARAGE FLOOR ~1 ELEVATION PER PLAN ELEVATIONS PER PLAN DRIVEWAY SLOPE PER PLAN (14% MAX.) "WHEN DRIVEWAY GRADE DIFFERENTIAL EXCEEDS 81/. TYPICAL LOT SE2TION PAD HIGHER THAN STREET 2% MIN. TYPE "G" CURB-~ & GUTTER w i2 < > i in ,ri :ii "l " ~~~ .. "~ 4" PCC SIDEWALK B" WATER MAIN PARKWAY STORM DRAIN (PRIVATE) B" SEWER MAIN (PUBLIC) (PUBLIC) TYPICAL SECTION SEAWORTHY WAY (PVT.) STA 1 + 4 7. 6 7 TO ST A 3 + 4 2. 7 7 NOT TO SCALE EAST WEST If. 45' COMMON LOT/GENERAL UTILITY AND ACCESS EASEMENT If. 2.5' 32' 10.5' PARKING BAY~~-i-----,----~~--cr-----------t..-c~'---'1 2:1 2:1 3.5' 10.5' ~ ~ID "' ;: STORM DRAIN I (PRIVATE) :, in B" SEWER MAIN (PUBLIC) 12' 11' 12' 7' 5.5' 5' TYPE "G" CURB & GUTTER B" WATER MAIN (PUBLIC) TYPICAL SECTION SALTIE COURT ~VT.) STA 3+95.27 TO STA 5+46.4 SOUTH If. NOT TO SCALE 53' COMMON LOT / GENERAL UTILITY AND ACCESS EASEMENT NORTH If. 10.5' 32' 10,5' 5' 5,5' PARKING BAY . 7' 12' 11' 12' 7' 7' 2', 2., 2% ~t===-~" ~-7f· ~ 10,5' 5' 5.5' 12' 11' 2o/. --'- 24' 10' 7' 2o/. -3' 5,5' 5' Z¾ ~ 7' PROPOSED G,U.E, T" I-- SIDEWALK . PARKWAY U) w i2 ;: TYPE "G" CURB & GUTTER 6" WATER MAIN (PUBLIC) "6" SEWER MAIN · STORM DRAIN (PUBLIC) PRIVATE 'El" USE SPECIAL PIPE PER DEPARTMENT OF HEALTH SEVICES, TYPICAL SECTION SHOAL COURT ivT.) STA 1 +33.19 TO STA 1 +50.4 NOT TO SCALE • 33037 "AS BUILT" REV~. D-n•. a.J.._ ~'( xlRDAN INSPECTOR DATE 1-5-l'f -~''""' DATE I SH2EET I CITY OF CARLSBAD I SHEETS I 1----1-----+-----------------+-----1:----+-----+-------1 ENGINEERING DEPARTMENT 13 1-----1-----+----------------+-----ll----+---t-----l 1---------+-----+---'-~~--~-~~--~~-----~--~---------t----+--+----1----< GRADING PLANS FOR, ~~ ~ ~ ! ~~\6" . ~ "' <i 4" PCC SIDEWALK TYPE "G" CURB POINSETTIA PROPERTIES (THE TIDES) & GUTTER PARKWAY B" WATER MAIN (PUBLIC) B" SEWER MAIN (PUBLIC) RECLAIMED WATER (END @ StA. 1+41.00) (PUBLIC) TYPICAL SECTION LAZARETTE WAY (PVT.) STA 1 +46.86 TO STA 3+29.15 NOT TO SCALE Y 05-01/Plll 05-08/COP 05-2 APPROVED, GLEN K. VAN PESKI · .. -.,. ... -.. '.·' ~{ SENIOR c1v1 ENGINEER'' 'PE 41204'EXPI~ts 3/31/13DATE . -.· • 3" AC AND 4" AB BASED ON GE OtE CH NI CAL RECOMMEND A Tl ON, 1---1----t;,r----,--:--=-c-:-:-.::------------t---l---+---t-----J ~:::::::::=::::==:::;;;;:::::::::,-;==:;:;:==::::::::==:==:::;;:::;;:::::::::::=~ FINAL SETION TO BE FIELD ADJUSTED PER GEOtECHNICAL DATE INITIAL AS-SUllT DATE INITIAL DATE INITIAL OWN BY, -7i'§E""t0-.,-;---PROJECT NO. DRAWING NO. RECOMMENDATIONS. MATERIALS PER CITY S7"ANDARDS REVISION DESCRIPTION CHKD BY, CT 05-10 469-BA AND/OR "GREEN BOOK," ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY, - n519' '\ J ' I 12" X12" ATRIUM GRATE, NOS •1200 12"x12" ADAPTER; NDS •1230,-~ W/ UNIVERSAL OUTLET. TOP OF GRATE (TG) ELEV PER PLAN 8" CONNECTION USE 12"x12" ADAPTER, NOS •1221 FINISH GRADE~ 4" /, '1//4'¾ ~,v, " ½ 4" PVC RISER PROP. HOUSE 0 12" RCP PIPE ;:WYE CONNECTION '------'-I SLOPE PER PLAN FLOW LINE ELEV PER PLAN I© LEGEND ON PLANS ATRIUM DRAIN WITH RISER (PVT) NOT TO SCALE PL 5.0' TYP (4.5' MIN) 3.0' PROP.6'FENCE AT PL '- EXIST ~ GROUND R/W GRADING DAYLIGHT (MATCH EXIST GRADE) 1.0' TYP CONCRETE BROW DITCH PL PER D-75, TYPED SECTION A-A SCALE: 1''= 10' 5' SOUND WALL <PER LANDSCAPE PLAN) PAD.ELEV 129.4 SOUND WALL (PER LANDSCAPE PLAN) 1' BENCH TW 119,60 RET. WALL <TYP) j : PAD=121.1 'l;'.;).';..u,r=-= ~.l:rr FG , 5' 30-50 MIL HOPE LINE WITH ALL LAPS SEALED PER MANUFACTURER'S SPECIFICATIONS R/W . . . INF IL TRA TION RATE. SOIL MEETING THIS SPECIF[CA TION TO BE VERIFIED BY THE GEOTECHNICAL ENGINEER. 4" PERFORATED PVC PIPE 1.0¼ MIN. INSTALL ALONG CENTER OF PAD WITH PERFORATIONS ORIENTED DOWNWARD ENCASED IN 1;x 1' CLASS II, OPEN GRAVEL, ½" DIAMETER AND WRAPPED IN MIRAFI 140N FILTER FABRIC • NOTE: SOUND WALL (PER LANDSCAPE PLAN) FL 101,76 SPLASH BLOCK RETAINING WALLS WITHIN B!ORETENT!ON AREA TO BE LINED BELOW ELEV 101.5 PER SOILS ENGINEER RECOMMENDATIONS B!ORETENTION PAD= 101.5 10"CONCRETE l PER MANUFACTURE RESTRICTOR 24 ,, RCP PLATE W/ 1.5" ORIFICE OPENING STROM DRAIN TW VARIES FROM 102.50 TO 107 .50, REFER TO PLAN FOR EXACT LOCATIONS ' SECTION B-B SCALE: 1"= 10' 18"(W)x13"(H)x1/ 4" GALVANIZED PL PL I PL 8.6' SOUND WALL I · SOUND WALL PAD= 118.5 1' BENCH. I . (PER LANDSCAPE PLAN) 5' (PER LANDSCAPE PLAN) FL 102.03 6" PVC TW 115.30 RET. WALL (TYP) PAD=118.5 TW 106.60 R/W 6,8' MAX <TYP) FG FG 108.5 / / 4' ,.,,-'--0 G 3"MIN / (TYP~ARIES 7:,'\-1;t-?""-;9,;,:9°,8.w;T¥ion1o"0".2' GRADING DAYLIGHT <MATCH EXIST GRADE> SECTION C-C SCALE: 1"= 10' SECTION ABOVE REFLECTS DESIGN & ELEVATIONS FOR LOT 7 ONLY FL 102 0 1.5" OPENING R/'11 TW 117.40 RET. WALL (TYP) 5' TW 109.50 7:,\ 6'MAX <TYP)FG 111.4 / 12'• 3"MIN ~OG (T ~V RE 103.0 TO 103.4 LOT 12 PL GRADING DAYLIGHT (MATCH EXIST GRADE) SECTION D-D SCALE: 1''= 10' • NOTE: 14' FOR LOT 10 SECTION ABOVE REFLECTS THE DESIGN i INTENT FOR LOTS 8-10, ELEVATIONS SHOWN ARE SPECIFIC TO LOT 9 TW PER PLAN ,;--3• MIN <TYP) PAD ELEV. R/W TW 111.70 , PL 6'MAX J_ (TYP) STEEL PLATE SECURELY ) 'II I MOSQUITO SCREEN SWALE FL SEE PRECISE GRADE PLANS • PER PLAN 2: 1 <TYP) RETAINING WALL WHERE SHOWN TF PER PLAN FG PER PLAN • NOTE, SLOPE TO BE 2¼ MIN, 21¼ MAX TYPICAL SIDE YARD W/ RETAINING WALL. <2) 30' FRAM£ AND COVERS <SEALED/BOLTED) AT 116,70' 12' HDPE OUTLET T□ ',IQ DETENTION AT 105.55' B. L 7' 12· HDPE OUTLET T□ \,{Q. V DETENTION AT 105,55' NOT TO SCALE 24• RCP INLET PIPE AT 105.97' PLAN VIEW NOT TO SCALE <2) 30' FRAME AND COVERS /<SEALED/B□L TED) AT 116,70' k:: 1' 1-1,.. 01'- SECTION VIEW B-B NOT TO SCALE GENERAL NOTES: BAYSEPARATOR FS 4x4 (LOW FLOWl GRADING DAYLIGHT (MATCH EXIST GRAD 5' - 24' HDPE STUB OUTLET PIPE AT 105,97' B _J 1, SEE BAYSAVER SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR FURTHER DETAIL. LOT 12, VAR[ES ~±:j,FG-11-3.6 I - 3"MlN (TYP) FUTURE SOIL TIE BACK FASTENED TO WALL OF STORMTRAP W/4-3/8"x2" GALVANIZED ~AG BOLTS W/ ANCHORS. I----Jll::--::-:2=-'0':;':;:0'-::'•:--.L.....-----1 EASEMENT TO CALTRANS FG 105.7 WIDTH VARIES PER LOT MATCH 1.5" ORIFICE OPENING WITH FLOWLINE. ~ ----------FRONTVIEW ,i, \i!. FL EARTHEN SWALE PER PLAN FUTURE EASEMENT LIMITS •NOTE, 17.50' FOR LOTS 10 & 11, 20.50' FOR LOT 13 & 22.50' FOR LOT 14. SECTION E-E SCALE: 1''= 10' SECTION ABOVE REFLECTS THE DES[GN INTENT FOR LOTS 11-14, ELEVATIONS SHOWN ARE SPECIFIC TO LOT 14 -F:-t HINGE LINE WHERE SHOWN ON PLAN r IPAO I E TOP/TOE OF SLOPE OR DAYLIGHT LINE _ ,.j;' PROPERTY LINE ,.j;' (;j -CURBLIN~ 1--(;j ~ . F . ~ FINISHED LOT GRADING TYPICAL LOT GRADING NOT TO SCALE NOTE: WHERE BOTH CUT AND FILL OR BEDROCK MATERIALS OF DISSIMILAR EXPANSION CHARACTERISTICS ARE EXPOSED IN THE BUILDING AREA, THE CUT PORTION OF THE BUILDING AREA SHOULD BE UNDERCUT 3.0 FEET BELOW PAD GRADE OR AS APPROVED BY THE SOILS ENGINEER, AND REPLACED WITH COMPACTED SOILS SIMILAR TO THE FILL MATERIAL, PL EASEMENT SOUND WALL GRADING LIMITS (PER LANDSCAPE PLAN) Et1~~ftT II 1' BENCH ; 1---.:.:<S=EE::....:._PL=-Ac..:N:_) --t PAD=121. 1 FG CONCRETE BROW DITCH PER D-75 SECTION F-F SCALE: 1''=10' GRADING DAYLIGHT SECTION ABOVE REFLECTS THE DESIGN INTENT FOR LOTS 14-19, ELEVATIONS SHOWN ARE SPECIFIC TO LOT 14 P.U.E. AND PL 10' VARIES (SEE PLAN! NOT TO SCALE PL 3.5' TW VARIES ( y 7 1' BENCH _(S_EE PLAN) i _L ~ _ -t-,01rn'--- RET. WALL <TYPl 3" MIN <TYPl ~-GRADING DAYLIGHT (MATCH EXIST GRADE) SECTIONG-G SCALE: 1''= 10' SECTION ABOVE REFLECTS THE DESIGN INTENT iFOR LOTS 19 & 20, ELEVATIONS SHOWN ARE SPECIFIC TO LOT 19 BACK OF LOT OR TOE OF SLOPE ~ ~!_.OT WIDTH VARIES-SEE PLA~f er: -ocn 2 LL W _J a. I ~ I ~ _J I TEMP BERM I( SLOPE PER PLAN FINISH PAD GRADE <TYP) V) .,F-----.J!_--=-=~ -- -~ ;;~ED GRADE AT FRONT PROPERTY LINE SECTION E-E NOT TO SCALE w z _J +---1 DJ O' ::J u -20' " u <( DJ w >-z w_ C/) _J SEE DETAIL "L" VARIES PAO ELEV.SHOWN ON PLAN TYPICAL LOT CROSS SECTION F-F SIDE VIEW I)__ :::,O<J: O' _J f--w Vl W ro o _J f--_J w n: u:w -V) 0 -SLOPE PER PLAN SPLASH WALL PER DETAIL THIS SHEET L•IO' / TW VARIES (SEE PLAN) FG R/W 3,67 r--,,--3• MIN <TYP) _i.,----OG , fMRlf 6~\~1i\LI~~ADE> SLOPE VARIES (2¼ MIN, 2:1 MAX) RET, WALL (TYP) SECTION H-H SCALE: 1'~10' SECTION ABOVE REFLECTS THE DESIGN INTENT FOR . LOTS 20 & 21, ELEVATIONS SHOWN ARE SPECIFIC TO LOT 21 8" ~ LJ ~-MpUND GROIJT i 8' CONG. BLOCK G . ;i: SPLASH WAfl. •4 8/JR @ 24' O.C. --· / !:ic ~ GROIJT CORES 1129,: SOLID. •4 8/JRS FUU LENGTH CONCRETE DfTCH l,J pc: 3" =t:~ lclR : · SPLASH WALL NOT TO SCALE ENiNEER OF WORK RIC ENGINEERING CO. •• E. 33037 f"AS BUILT" NOT TO SCALE BROW DITCH CONFLUENCE J w z w _J NOT TO SCALE EXP. r,/~o/ 14 DATE REiVI WELJ;~ ~f>·l'1 :J"A'\t'fJ'ORPW +rt{rt:ft2 • INSPECTOR DATE 2. USE NON-SHRINK GROUT TO SEAL THE INLET AND OUTLET PIPE IN TO THE VAULT STRUCTURE. 3, 24" HOPE STUB OUTLET TO CONNECT TO RCP PIPE OUTSIDE VAULT. z :J 10.5' 20' " J-----"'-"'-~-t----~--~U ~ >-15' 5' ~ ::J f--c- LOT LINE PROPERTY LINE I SH3EET I CITY OF CARLSBAD I SHEETS I l---t--+--~'-------------t---+--t---t--1 ENGINEERING DEPARTMENT 13 l----+---1---~-----------t---t---t----,-, ~G:;:RA::;D;:IN==G:'...;:PL==A==N:;:S~F;;O;:R,:::=":==::::::'=::=====.::::=::=~ 4, 12" HOPE STUB OUTLET TO ONNECT TO RCP PIPE OUTSIDE VAULT, RICK 5620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 J-14826C ~ (FAX)619.291.4165 ~ ENGlNEERlNG.COMPANY -------'!!!'!'-!"!"'IIIJll!'!"'!!l_,",iick!lleii!ng!l'in,ijeei!iiril!ng[ii,.ciiiiiom Q San OieS:o RiVerside -Orilrigfi! • San Luis Obispo·. Bakersfield -Sacramento• Pho'enix.-Tucson R, \ 1 4826\Grad lng\1482'6.,;wd.03. d,;in \ \srv.r I i;,t \R lckStondqrds\Bent I ey.2QO'!\work~paoe'-pn;iJ<Jcts\CorpS r(ls.20\)5.SD\ lpl ot\i;:orp':?tdL?i:)Q5.$Q. ram I i--/;M'l-"<01 l 07, Yl: u ~ ~ POINT"A" ~ 0 _J .;;:,,__L__c_ __ _ 21/. ft TOP OF Cc,rUR:B:::J,r_::""'~=r--==-=-= \. TvARIEs* \ROUGH LOT GRADING DETAIL L NOT TO SCALE SLOPE PER PLAN 2,1 MAX SLOPE HINGE LINE 3' TEMPORARY BERM AT TOP OF SLOPE NOT TO SCALE POINSETTIA PROPERTIES (THE TIDES) APPROVED: I AS-l!,Ult.T DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: REC CHKD BY: Dell. RVWD BY: PROJECT NO. CT 05-10 DRAWING NO, 469-BA \ 1 RICK / / 5620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 (FAX)619.291.4165 J-14826C SEE SHEET N0.5 PO~NSETllA LANE ', ' \ :,:· ,<,, h!--WALL ·i,17 3' SEE SHEET 10\ FOR WALL DATA 22 (133!0) " PRIVATE STORM DRAIN DATA NO. DELTA OR BRG. RADIUS LENGTH REMARKS N67"29'01"E 44.01' 4" PVC (PERFORATED) 2 N12" 32' 18"W 59. 43' 1 211 RCP 1350-D .. ----~-- 3 N77" 27' 42" E . 8.6'4' 24 11 fiCP t,oO-D 4 N77" 27' 42"E 22. 50' 2411 RCP j,;OO -D 5 6= 11" 24' 02" 200, 00' 39. 29' 24" RCP -D --+-------+------+----+---~ 6 N57' 30' 07"W 92. 28' 24" RCP 1350-D 7 N18"10'31"W 32.26' 18" RCP 1350-D 8 N49"27'22"E 26.63' 18" RCP 1350-D 9 N12"38'14"W 7. 74' 24" RCP 1350-D 10 N72"49'34"E 27.84' 18" RCP 1350-D 11 6= 05" 43' 55" 200. 00' 20. 01' 18" RCP 1350-D ~-+-------+-------t-----+--- 12 N12"32'18"W 140.43' 18" RCP 1350-0 ~-+-------+-------t-----+---~-----· -·-- 13 N67" 29' 01 "E 13. 17' 4" PVC <PERFORATED) 14 N12'32'18"W 8.84' 4" PVC (PERFORATED) ---·· 15 N81' 19' 32"W 11. 31' 12" RCP 1350-0 16 N16" 33' OO"W 13. 57' 6" PVC 11 :No;•;:,•~1•w~ -¼.oo • l'1" FiCP 1350-0 -~--------------.,,--.~- LI NE TABLE NAME DIRECTION LENGTH L1 L2 L3 L4 L5 L6 L7 LS L9 L10 L 1 1 L12 L13 L14 L15 L16 NAME C1 CZ C3 C4 C5 C6 C7 cs C9 C10 C 11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 N 1 3' 05' 23" W N 74' 54' 52" E N 56' 33' 46" E N 74'54'52" E S 33'57'51" E N 1 5' 04' 3 7" W N67'29'01"E S 74°45'05" E N 89' 55' 26" W N 1 2° 32' 1 8" W S 70° 35' 1 3" E N 5'04'17" E N 1 2' 32' 1 8" w S 24'00'21" E S 78°40'41" E N 24°00'21" W CURVE TABLE DELTA RADIUS 7'43'29" 15"25'31" 19"37'19" 20· 24' 24" 20· 28' 44" 11"31'43" 35• 14' 03" 53• 18' 08" 52' 50' 22" 38' 26' 44" 87"27'41" 81"04'16" 16' 28' 56" 23' 35' 01" 49'15'01" 49' 25' 34" 49' 34' 54" 1'18'33" 49• 39' 02" 52' 00' 19" 29' 50' 54" 92' 28' 18" 5" 12' 00" 1°15'27" 87' 27' 44" 40"03'57" 6' 27' 26" 25.00 73.00 73.00 73.00 73.00 73,00 20.00 30.00 30.00 20.00 20.00 20.00 20.00 20.00 29.00 29.00 29.00 1 59. 50 29.00 29.00 20.00 20.00 219.50 219.50 20.00 20.00 219. 50 FOR IMPROVEMENT PLANS SEE CITY OF CARLSBAD DWG NO. 469-8 1 5. 75 1 4. 1 2 1 1 • 6 7 1 o. 70 1 8. 84 1 5. 75 20. 1 7 1 9. 66 1 1 • 6 7 4. 82 1 0. 22 1 0. 30 4. 1 9 17. 2'l 14.92 1 3. 22 ARC 3. 3 7 19. 65 25.00 26.00 26.09 14.69 1 2. 30 27. 91 27.67 1 3. 42 30.53 28.30 5. 75 8,23 24.93 25,02 25. 1 0 3. 64 25. 1 3 26. 32 1 o. 42 32. 28 19. 92 4. 82 30,53 1 3. 99 24. 7 4 ANY WORK TO BE COMPLETED WITHIN THE CAL TRANS RIGHT OF WAY WILL BE ACCESSED FROM WITHIN THE PROJECT PROPERTY. EXISTING FENCE ALONG CAL TRANS REQUIRED TREATMENT CONTROL BMP TABLE RIGHT OF WAY TO BE PROTECTED D \ • / ll 1 , . SIG ,T "' ' il; i LINE, t . I'. I SEE SHEET N0.5 QUANTITY IN PLACE. ANY PORTION OF THE FENCE THAT IS DAMAGED WILL BE REPLACED PER CALTRANS STANDARDS. ORK " BUILT" EXP. r,/~o/ 14 DATE 3·S·f'f ~m DATE ~ ENGINEERING COMPANY rickengineering.com <i!JR..:;Sa~o~D;.!ieg;o=====-:::•;;;:v•;::r,i::;d•:.;,·,;;;Dr::";:••:.;·.;;S•::;n.:;:Lu:;:;'.,::O:;;::b;;::•P;:_o-;,::B:;•k;::•~:::fi•::;ld:,,;·;::S•;:",::'m:::•::;oto::.;•~Ph::o:;::•n::lx,;_-T:,::uc:::;~o:::;n ________________________ ,_...;.....;... ____ _,..,;..;._...., ___ _;G;.:,R;;:A;;:,P_;H.:.;l,;;;C....:;;S,;::C;;;A:;:L:;:E;_;,1'_1 ;::_· ,:2.;:0~'-------------------------------..;...--------------------------------,-,"~r":f"~) R, \ 148?.6\Gr-ad I Cl\.)\ I 4821; Qf<j,.04, ~Qn ! ~: :'..,<,,:. ·,;,._" ;, ~-·-••;· ~-~;; · ;/ '.: ! ; · .. ,; :'.'~•-;; r , ,,,,;t <·'!':'.' r-~ ! ~,,. -;v-. i ,·, ! '> ,, .-Jr:·-::~, S ~-~-~'. ';~: ; ''.( - 0519'11 i' <:·: •-:-,:,,: \ ...... •, 't ,::(f,•T RICK • \ ':~: -~ \ J-14826C '·,) .... ! : ..... · .. ,: c·, ... ,f ... . ,•' \ \ \ .... ~;: ........ .. . '• ·····. 20 10 0 20 40 60 --- - RADIUS LENGTH REMARKS 150. 00' 33.46' 1 8 II RCP 1350-D 150. 00' 43. 45' 1 8 II RCP 1350-D 47. 78' 1 8 11 RCP 1350-D 91.46' 1 211 RCP 1350-D 13.78' 1211 RCP 1350-D LINE TABLE NAME DIRECTION LENGTH ------------------------- L1 N 13° 05' 23" w 15. 75 L2 N 74• 54' 52" E 1 4. 1 2 L3 N 56° 33' 46" E 11 . 6 7 L4 N 74• 54' 52" E 1 0. 70 L5 s 33°57'51" E 1 8. 84 L6 N 15° 04' 37" w 1 5. 75 L7 N 67° 29' 01" E 20. 1 7 L8 s 74• 45' 05" E 19. 66 L9 N 89° 55' 26" w 1 1 • 6 7 L10 N 12°32'18" w 4. 82 L 1 1 s 70° 35' 13" E 1 0. 22 L.1 2 N 5° 04' 17" E 1 0. 30 L13 N 12°32'18" w 4. 19 L14 s 24' 00' 21" E 1 7. 29 L15 s 78° 40' 41" E 1 4. 92 L16 N 24° 00' 21" w 1 3. 22 CURVE TABLE NAME DELTA RADIUS ARC ---------------------------- C1 7'43'29" 25.00 C2 15' 25' 31" 73.00 C3 19°37'19" 73.00 C4 20· 24' 24" 73.00 cs 20· 28' 44" 73.00 C6 11°31'43" 73.00 C7 35°14'03" 20.00 C8 53• 18' 08" 30.00 C9 52°50'22" 30.00 C10 38° 26' 44" 20.00 C11 87"27"41" 20.00 C12 81'04'16" 20.00 C13 16"28'56" 20.00 C14 23'35'01" 20.00 C15 49'15'01" 29.00 C16 49'25'34" 29.00 C17 49• 34' 54" 29.00 C18 1'18'33" 1 59. 50 C19 49' 39' 02" 29.00 C20 52' 00' 19" 29.00 C21 29" 50' 54" 20.00 C22 92' 28' 18" 20.00 C23 5'12'00" 219.50 C24 1'15'27" 219.50 C25 87' 27' 44" 20.00 C26 40'03'57'' 20.00 C27 6' 27' 26" 21 9. 50 FOR IMPROVEMENT PLANS IN THIS SHEET SEE CITY OF CARLSBAD DWG NO. 469-8 ANY WORK TO BE COMPLETED WITHIN THE CAL TRANS RIGHT OF WAY WILL BE ACCESSED FROM WITHIN THE PROJECT PROPERTY. EXISTING FENCE ALONG CALTRANS RIGHT OF WAY TO BE PROTECTED IN PLACE. ANY PORTION OF THE FENCE THAT IS DAMAGED WILL BE REPLACED PER CALTRANS STANDARDS • . -F' LT" 3. 37 1 9. 65 25.00 26.00 26.09 1 4. 69 1 2. 30 27. 91 27.67 1 3. 4 2 30.53 28. 30 5. 75 8. 23 24.93 25.02 25. 1 0 3.64 25. 1 3 26.32 1 0. 42 32.28 19. 92 4. 82 30.53 1 3. 99 24. 74 ~ /-/o-lf' .C.E. ??iQ2 7 EXP. <,L~ot14 DATE ' --l-----,--l---------------t----t--t------------j-, 1 sH5EET I CITY OF CARLSBAD I SHEETS I ,--ENGINEERING DEPARTMENT 13 ::;G;;:RA;::;D;:IN;;G;:._<;P;::LA;:;N;;S~FO~R~, ==:=::::'::::"=::::::::'.::=::::::=::::::__:====; e-------+-----1-----~--------t---t----t----r--, POINSETTIA PR OP ERTIES (THE TIDES) V 05-01/PUD 05-08/COP 05-2 >----+----+---------------t------t---r--;--------,· APPROVED: _., ..• x'i/,:2n A ii'_"' .. GLEN K. v~~K[ SENIOR CI L ENGINEER PE 41204 EXPIRES 3/31/13 DATE I AS-BUILT DATE [NITIAL ENG[NEER OF WORK REVISION DESCRIPTION DA TE [N[TrAL DATE [NIT[AL OTHER APPROVAL CITY APPROVAL DWN BY: REC CHKD BY: \) E (C RVWD BY: PROJECT NO. DRAWING NO • CT 05-10 469-SA S620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 (FAX)619.291.4165 ~I ~E~N!GI;N~EE:RIN:G:C:O:M:PANY=~· _;;;;;:~;;:;~~~!;;:~;1:EE~;;;';tc~k•:n~g!!'l:niiie~•~r-ln!g~,c~om:_ __________________________________ :G~RA:.::..PH~l=C...:S:C::.A:L:E...:.1"_=_2:.0::.'-:-----------------------------------------------------------7r-;---~c 9L San Diego River.side •Orange• San Lui5 Obispo -Bakersfield• Sacramento-Phoenix• Tues.on R• \ 1 4826\Gradln,;i\ 1 4826-11rd.05. d,;in \ \ srv .r I b ! \R I ck5tondord s \Bent! e1 .2006 \\o'orkspac.a\pro J octs\CorpStds.2005.SD\ Ip I ot\CorpS tds-2005. SO. pen -•.,,non .. ,-, •~ - 051911 ; I ' •••••• t --• 0.,-,~ ','=S M O MO +--l~,~1 '. -·t-·: ;-c-:-:-"'-• ~" ,,_ 'a=±+ ~- -~ ~-~-"'--" -. --- •, --' ····-~----,-.. ' ' o; .. &•-~-~~ , ~""""•• . ~ -.• CSIO ~-"~";~.~~ -· .,,:¾;:":~ .. .. ' . •·· tt ..:,/¢ .. •: •~:•,::•:~:OllO -•:~i• :EH·,¢ .i<t ""· -:1 _-_ , · l· -" 1 " .... --- . --,s:;;;,< -··! , ' ' . ,. . . . ,., '. ' '· ..... ' . ' . ·,.::1,-:::,:TI " D1;·t1 1 '""'''" -• Qt5'-12· GP.· , ·_ . F . . . ... . ~ . ~ ittGHT JO.jN l .,. -r·· ' . . , ·i . . . . ' ....... . .. . . .,.,, . " . ! '. •. ;- _ _. .......... . • .4 ..... ;. .---~-. . ' . ,_ ~·-:.:·.~ ·~:.: ... •so! lllll£. A ?•.l4'.f24ffi '~~. !" ·o"''C , .. !:fit :~.;,:., ' ·" ····•15 ''la ·'Ff> ,. ·~ ~ ... r .. -... -· ... ·-... , ,.·,-·---'. ' . ~; .. ; ·:.;.....;:: ·+--· -+ -, . ··• .... ,, -·' ···;-. ' +· ... · .... -~-., ., ·• .. '." '. . Thl"=-U1Jf ' . . ... . . •··· +5:J 2¥1-·' 1. ··~ 1:C~. :. I :: ·• . • , ..... . • Oe'•·@i C '. ...... ,,. ..... _..... . . • . I EfHl:i . "" .... I . .... . . I •••• . • < •• ' i I il1 L , .... ' t RICK ,, iii ENGINEERING COMPANY @ San Diego R, \ 1 4626\Grad lrig\1 4826_<Jr"\L06, dgn ' 5620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 (FAX)619.291.4165 J-14826 ri eke n gin e er in g. com Riverside. Orange• San Luis Obispo • Bakersfield . Sacramento • Phoenix. Tucson \ \,;rv r I b1 \RlckStandords\Bant I ey_200G\work.;pcce\p..-0Ject5\CctrpStds.2005.SD\ Ir> I ct\CcrpStds.2005.SD pen ..,, ,,,o ..,, '. i' ~ ... NOTE~ ALL STORM DRAIN IS PRIVATE . ' .. .,. . . ··----), __ :-·. . . .. -.. -... ' -'. ... ---. -~----~------¼ .... . ----.. . . .. , .. . . . -... -=~·~~ . . . -... ' M + « • ~,---+,,e"w.+,. ... I.: .. . , .... ... 0 ·~·¥:-.-~": .• : .:.? . i--l ::z. --· ~---r- :~,~> ~•M-•M • o -~ -• • :•f • • F-~ .I 1--... : -,.. -:: --_ "': ., • l '""~'. i ,. ·1 • . ~ I :H:: f . . 0 ::.tri:s;/, f~:~:~ ·: ~-, . f•• .. -•• C : • • • •• ' ••• • ·;,. · ·· ····· · .. -·, 1-R ~•tt,,ia:p;; . ., . .. . .. , ;· "d··:;· .. ij"" i I • 1 0:: ·· T ·1 ·7 :::J ,: :'· .! . ~:O: :t: .. j: • . ...... :.l:fJ; . . ; --i A < · · · i ·tt. _, . . ' . . . -_, f' ·i --1 ' ' -' . --. J. ... . ; . .,_ -FS':. .. '"""""" •m • • •~• ::. __ _i,. •. ::. ·s ,,. .,_ .; :: .. -----"'.~:v-· -4 • ·-. --➔ , ... ' ••• 'llll_;;;;;;;±"'c:illJ'l l . .. ·······:. r:: "" • ••• "<"· .,. e '/( . 't..;:..l:";"=~==ll"""!c,'••'f' !EIE:±31 1m ;·~ . ; T I • 1: T .. .... -, ... -""""""'''~ -... •••• ••>••· ••• ,. . ' .. . ..... , .. , .. ·-~-J ... , . ---_,-,::::::,;;,,, -.J .. . ,°::::1:,.; -"~;.~~t~,"' """, ~:'. ~,:_~, ,,~.-°""J__,~ .... L """°' ENGINE R OF WORK R E GINEERING CO. ' . ., 33037 .., .... ·'o:~.aah; 1 1"'1 .•·· . . 1.· ~tz:tG: f · .. : .~. .... I .. · ·. ~~T:Eff·t-·· ~ ·· •:C- . ·"T!~... !ii. · 1 ' · •-•·s1fc<a , ;. ..J l . . ,.. " l~~:'l•ta llll= w,~~111111 -,,z,.ig,jl'e : ;· . I .. ""' !---r·......::..::: . ; ~"= :i · E. •!A:i'JiE:e I -i•··: .. ,,.. · r j •• j j ·::: .. !-: .·::.':.::: ----' :',-··:·1:·:·, ,. . ' . ... .. :. ::.: ,. ' . ,~~t-,.q,~ •• ' •• • > •• . ' . . .. ·-. 1 .· I • -. -.i , .... ·-....... 1-:~--'....! 0 • ' . •• 1--• . :.;;:.::r,;· ~-r-:: :;i .. . ·~ ...•. ·,·, -r,r .: ~ : r+,'+' ·:r, , ~mciL ·a.,::~~t . . . I .. c ·:; . ,,, .. ··1 .... . I .. ,, .. .,.. ... • . .. .. ,.. . ' .:/ .. [: .::··:~ . , .... ;· .. , : :'. ·:·:· .;::: _-··:: --=1=-.· ·:·y ... t ... r-. j 1 : ···1 t I' 1 1 I : , · i i I lf1 ···f't·!··1 ··•:··;··' '•:·;·i···j i :: .. ( ..... " ! I j .. , ' j •• ' · , ••.. -1--· 1 I ~· -· h 1t;.::::,;; ·. ;· .,. • •:,o,,; • •1.~~l . .:;,;~•-~J 4;;t •:~~:~Wf t ;,,~~0: "'::i):~;.:::] •• ' ..... • 1 • l·-~ z-; · , t ; .. ·· · , --···i:: ··• l···a-< • ••~•::r::::: . ! .. ' ·:·::·:::1::·::·:§J ~ . . • '. < • , ... :~ ~;. : . J I • ···1 I .. 1·•·_j""·1 ···• 1: . + j ,· i"·u:.; Me; 1 --· -r l - 1 I · 1r 1 ~•-·· I J I ..~--i ·:! : l . I. .. i I I l .. '. .. .r . . •.. [NSPECTOR . . -.. -, ··-r···1 j ' IL T" DATE DATE ...j ... I .. , =w~·• t " , L,;,;L••= ~ CITY OF CARLSBAD I SHEETS I I :,I.TE 1------+-----------------+-------------1 L.§_J ENGINEERrNG OEPARTMENT 13 1------------+-------------------------+--------------------i Afi-6</llT DATE [NIT[AL DATE !N!TrAL DATE [N!TIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL C[TY APPROVAL GRADING PLANS FOR: POINSETTIA PROPERTIES (THE TIDES) V 05·01/PUO 05·08/CIJP 05·2J APPROVED:~ '¥_-z,J;, :4¥ GLEN K~ YAN P~;Kl SENIOR CIV1ENGINEER PE 41204 EXPIRES 3/31/13 ~ OWN BY, CHKD BY: RVWD BY: REC PROJECT NO. DRAWING NO. CT 05-10 469-8A J 11 051911 i ; i ' 1. 2. STORMTRAP INSTALLATION SPECIFICATION STORMTRAP MODULES SHALL BE MANUFACTURED ACCORDING TO SHOP DRAWINGS APPROVED BY THE INSTALLING CONTRACTOR AND ENGINEER. THE SHOP DRAWINGS SHALL INDICATE SIZE AND LOCATION OF ROOF OPENINGS AND INLET/ OUTLET PIPE OPENINGS. STORMTRAP SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C891-90, STANDARD PRACTICE FOR INSTALLATION OF UNDERGROUND PRE-CAST CONCRETE UTILITY STRUCTURES. THE FOLLOWING ADDITIONS AND/OR EXCEPTIONS SHALL APPLY: A SPECIFICATIONS ON THE ENGINEER'S DRAWINGS SHALL TAKE PRECEDENCE. B. C. D. E. STORMTRAP MODULES SHALL BE PLACED ON LEVEL FOUNDATION (SEE SHEET 3.1) WITH A 1'-0" OVERHANG ON ALL SIDES THAT SHALL BE POURED IN PLACE BY INSTALLING CONTRACTOR. THE STORMTRAP MODULES SHALL BE PLACED SUCH THAT THE MAXIMUM SPACE BETWEEN ADJACENT MODULES DOES NOT EXCEED 314". IF THE SPACE EXCEEDS 314", THE MODULES SHALL BE RESET WITH APPROPRIATE ADJUSTMENT MADE TO LINE AND GRADE TO BRING THE SPACE INTO SPECIFICATION. THE PERIMETER HORIZONTAL JOINT OF THE STORMTRAP MODULES SHALL BE SEALED TO THE FOOTINGS WITH PREFORMED MASTIC JOINT SEALER ACCORDING TO ASTM C891-90, 8.8 AND 8.12. ALL EXTERIOR JOINTS BETWEEN ADJACENT STORMTRAP MODULES SHALL BE SEALED WITH PRE-FORMED, COLD-APPLIED, SELF-ADHERING ELASTOMERIC RESIN BONDED TO A WOVEN HIGHLY PUNCTURE RESISTANT POLYMER WRAP CONFORMING TO ASTM C891-90 AND SHALL BE O' -8" INTEGRATED PRIMER SEALANT AS APPROVED BY STORMTRAP. THE ADHESIVE EXTERIOR JOINT WRAP SHALL BE INSTALLED ACCORDING TO THE FOLLOWING INSTALLATION INSTRUCTIONS: 1. USE A BRUSH OR WET CLOTH TO THOROUGHLY CLEAN THE OUTSIDE SURFACE AT THE POINT WHERE THE JOINT WRAP IS TO BE APPLIED. 2. A RELEASE PAPER PROTECTS THE ADHESIVE SIDE OF THE JOINT WRAP. PLACE THE ADHESIVE TAPE (BUTYL SIDE DOWN) AROUND THE STRUCTURE, REMOVING THE RELEASE PAPER AS YOU GO. PRESS THE JOINT WRAP FIRMLY AGAINST THE STORMTRAP MODULE SURFACE WHEN APPL YING. F. THE FILL PLACED AROUND THE STORMTRAP UNITS MUST BE DEPOSITED ON BOTH SIDES AT THE SAME TIME AND TO APPROXIMATELY THE SAME ELEVATION. AT NO TIME SHALL THE FILL BEHIND ONE SIDE WALL BE MORE THAN 2'-0" HIGHER THAN THE FILL ON THE OPPOSITE SIDE. BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY OR OTHERWISE SPECIFIED BY ENGINEER. CARE SHALL BE TAKEN TO PREVENT ANY WEDGING ACTION AGAINST THE STRUCTURE, AND ALL SLOPES BOUNDING OR WITHIN THE AREA TO BE BACKFILLED MUST BE STEPPED OR SERRATED TO PREVENT WEDGE ACTION. (REFERENCE ARTICLE 502.10 I.D.O.T. S.S.R.B.C.) CARE SHALL ALSO BE TAKEN AS NOT TO DISRUPT THE JOINT WRAP FROM THE JOINT DURING THE BACKFILL PROCESS. BACKFILL MATERIAL NOT TO EXCEED 120 PCF SOIL DENSITY OR 80 LBS PER FOOT OF LATERAL SATURATED PRESSURE. RECOMMENDED BACKFILL TO CONSIST OF 314" COARSE AGGREGATE STONE OR APPROVED EQUAL AND SHALL CONFORM TO THE ABOVE DENSITY/LATERAL SATURATED PRESSURE REQUIREMENTS. STORMTRAP SPECIFICATION BACKFILL (SEE NOTE 2F) ~ ' I ' \ ·• /--EXTERIOR WALL 'x OFSTORMTRAP / \ " \ I \ I ALLOWABLE MAX GRADE= 116.17 FT EL ALLOWABLE MIN. GRADE= 108.19 FT, EL. ACTUAL FINISH GRADE= 116.10 FT. EL. r _____________ __,. ____ -INSIDE HEIGHT ELEVATION= 107.03 ~///;/f~yw@/?½ / =-1 t, . =111==1 11 -1 -. 1==11 1 -=rrr b--~• L·-I I I '---_ _ _, 10" CONT. REINFORCED CONCRETE FOUNDATION FOR STOP\1TRAP SYSTEM SEE SHEET 3,1 FOR DETAILS 5'-0" SINGLETRAP I \ I \ \ \ ', \ I \ \ \ \ \ ·-BEND TARP \ \ 8oz GEOTEXTILE \ \ OVERLAYMENT \ '---BEND TARP PPL-24 \_ --:~z~ ~~NREPR 8oz GEOTEXTILE UNDERLAYMENT --SYSTEM INVERT= 102.03 -' ---FOR FLOATATION CALCULATIONS GROUND WATER TABLE IS ASSUMED TO BE BELOW THE INVERT OF THE SYSTEM. IF DIFFERENT THAN ASSUMED, CONTACT STORMTRAP. 1. TOTAL COVER: MIN. 0'-6" MAX. 9'-0" CONSULT STORMTRAP FOR ADDITIONAL COVER OPTIONS. FOUNDA no,,._~ \ ' / 2. CONCRETE CHAMBER DESIGNED FOR AASHTO HS-20 WHEEL LOAD & APPLICABLE IMPACT. MIN. SOIL PRESSURE 1,500 PSF. 3. ALL DIMENSIONS AND SOIL CONDITIONS, INCLUDING BUT NOT LIMITED TO GROUNDWATER AND SOIL BEARING CAPACITY ARE TO BE VERIFIED IN THE FIELD BY OTHERS PRIOR TO STORMTRAP INSTALLATION. 4. FOR STRUCTURAL CALCULATIONS THE WATER TABLE IS ASSUMED TO BE 3'-0" BELOW GRADE. IF WATER TABLE IS LESS THAN 3'-0" BELOW GRADE, CONTACT STORMTRAP. 5. FOR STRUCTURAL CALCULATIONS THE SOIL DENSITY IS ASSUMED TO BE 120 PCF. 6. STORMTRAP IS NOT WATERTIGHT-PLEASE ADVISE IF A WATERTIGHT SOLUTION IS NEEDED. \, ;v--1"0 JOINT TAPE APPLIED AROUND '----.. , THE PERIMETER OF THE SYSTEM ONLY -.. -~---_,,-'✓- DETAIL "A" JOINT TAPE INSTALLATION 1-SHEET INDEX IP~GE DESCRIPTION --- COVER SHEET ' ' 2 SINGLETRAP INSTALLATION SPECIFICATIONS 2.1 SINGLETRAP INSTALLATION SPECIFICATIONS 2.2 SINGLETRAP INSTALLATION SPECIFICATIONS 2.3 · STORM LINER INSTALLATION SPECIFICATIONS 3 LAYOUT DETAIL ·---3.1 SINGLE TRAP INSTALLATION SPECIFICATIONS - 4 STANDARD -5'-0" SINGLETRAP TYPEI ~ 5 STANDARD -5'-0" SINGLETRAP TYPEII - SHEET NUMBER: 02 ---- REV. ~- 1 1 1 1 1 1 1 ----- 1 ' RECOMMENDED PIPE/RISER SPECIFICATION 1. CONNECTING PIPES SHALL BE INSTALLED WITH A 1'-0" CONCRETE COLLAR, ANDA CONCRETE CRADLE FOR AT LEAST ONE PIPE LENGTH, AS SHOWN. A STRUCTURAL GRADE CONCRETE OR GROUT WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI SHALL BE USED. 2. THE ANNULAR SPACE BETWEEN THE PIPE AND THE HOLE SHALL BE FILLED WITH NON-SHRINK GROUT. RECOMMENDED INSTALLATION INSTRUCTIONS 1. CLEAN AND LIGHTLY LUBRICATE ALL OF PIPE TO BE INSERTED INTO STORMTRAP. 2. IF PIPE IS CUT, CARE SHOULD BE TAKEN TO ALLOW NO SHARP EDGES. BEVEL AND LUBRICATE LEAD END OF PIPE. 3. ALIGN CENTER OF PIPE TO CORRECT ELEVATION AND INSERT INTO OPENING. --WALL OF STORMTRAP 1·/ / -NON-SHRINK GROUT II r--lNLET/OUTLET PIPE I NOTE: FOR ACTUAL PIPE LOCATIONS AND INVERTS PLEASE REFER TO SHEET3.0 I _/_c___ _________ ---1 PRECAST CONCRETE ADJUSTING RINGS AS NEEDED FRAME & COVER AS SPECIFIED BY ENGINEER 6 STANDARD -5'-0" SINGLETRAP TYPE Ill ----~~ TOP OF STORMTRAP CHAMBER --',--.___--.___, ·-. --, __ -, __ ___ CARLSBAD TRACT CT 05-10 1 ,sr /pro ,c atu/d_grµ 1US~$$UHU'1t$$r,1,,,, Jn ,e1tB1HHU$$1-$$1 /~ sr /pro _,:fo\a. "d_s,p /$5:!tti~U 1$1.Jsr _-.,,t le$1tU$U$$1 U ~,,,·,/JJv,')d 1~0 ''""$ . CARLSBAD, CA •. ----------- /,/1 ,I / 7 STANDARD -5'-0" SINGLETRAP TYPE IV ~--B STANDARD -5'-0" SINGLETRAP TYPEV ~---· -~ _' _1_·-_ ' JOB SITE INFORMATION f----- D ES CR IP T 10 N ---- JOB NAME: JOB ADDRESS: ENGINEERING CO: CONTACT NAME: CONTACT PHONE: CONTACT FAX: STORM TRAP SUPPLIER: CONT ACT NAME: CONTACT PHC~E: CONTACT FAX: CARLSBAD TRACT CT 05-10 CARLSBAD, CA RICK ENGINEERING COMPANY NOBUYA MURAKAMI 619-291-0707 619-291-4165 STORMTRAP TYLER KEEGAN 815-941-4663 815-416-1100 WATER STORAGE REQ'D: 6,091.00 CUBIC FEET WATER STORAGE PROV: 6,542.00 CUBIC FEET UNIT HEADROOM: 5'-0" SINGLETRAP UNIT QUANTITY: 20 UNITS -20 TOTAL PIECES SHEET NUMBER: 1 -- ,1, ' I i I 01 SHEET NUMBER: DETAIL "C" CONNECTION DETAIL -(NOT TO SCALE) 2.1 --- ---- ~--- ~ --- J,~\ TC: [J,li_~ll,IFFR - -NOTCH IN FOUNDATION TO ALLOW INVERT OF PIPE TO MEET THE INVERT OF THE FOUNDATION I --- -------- --- I/\ AS-f3UtlT lf\.lTl.4L -- -- C-F INOI\K REV ~:.1 C)\ [ 'TC,IPTlnl~ )-::-)__,:\ , _ __, Dl'.T:-.: :)TI-IFR BOTTOM OF STORMTRAP --._ RISER DETAIL 0 EDWARD D. '1-_, Ac~ r:: I j LT" " '2 LOSCH ~ _, ,__) \. "' "" w m a: 11~ m "' -- <l' C VIL ,,_ RC [ EXP Ll.4TE '11, )ii'· ----- t: Of CAU'iD'"I'- REV.lV\IFC BY EXP. 6/30/11 TA'f :rol<DAN ---- ll·ITc~TOR Di'~E r-----I SHEE-1 I ~El·JGl!~EEcilliG I SH;-J-r~- 7 ' 1 ,, l _:'__J DcYARHJ[NI ~ -- --IGR/'.\Dl~-IC-PU\~IS r-or ' POINSTTTIA PROPERTIES .. , THE TIDES) ·- -·' ! \! .U_S_-Cll./:.f/lJ_L'l __ 1J::08/CDP 05--'----'?'3 -A.! L<'•'• · -.... ,. : · ·•-" ,-o "•-'•• > .,/~:j Arc,c_ovrn _,&,,"')! ?/tb7 J12 GLrn K ¢~kl -- SEN I Of! c1v1r Er-✓Gl,\[FR ?F 41204 FXP!RE5 J/11/1 I ----------- DVvN 8 V PEC ,----PRO,IICT I\O ~~';!HSf;J -- ' !f\llTI.L>._ [,.r:,,, T:: I~~ I Tl ,L.1_ CHl<D 3Y: l)f IL. CT 05-1 0 - .C1.PPROVAL CITY A_jPR0 1/A.L R '-/VVD f-l "(: i A5-BUILT QS'\911 1. 2. 3. 4. 5. 1. 2. 3. 4. RECOMMENDED ACCESS OPENING SPECIFICATION A TYPICAL ACCESS OPENING FOR THE STORMTRAP SYSTEM RANGES FROM 2'-0" TO 3'-0" IN DIAMETER. ACCESS OPENINGS LARGER THAN 3'-0" IN DIAMETER NEED TO BE APPROVED BY STORMTRAP. PLASTIC COATED STEEL STEPS PRODUCED BY M.A. INDUSTRIES PART #PS3-PFC (SEE DETAIL TO THE RIGHl) ARE PROVIDED INSIDE ANY UNIT WHERE DEEMED NECESSARY. THE HIGHEST STEP IN THE UNIT IS TO BE PLACED A DISTANCE OF 1'-0" FROM THE INSIDE EDGE OF THE STORMTRAP UNITS. ALL ENSUING STEPS SHALL BE PLACED WITH A MINIMUM DISTANCE OF 1 '-4" BETWEEN THEM. STEPS MAY BE MOVED OR ALTERED TO AVOID OPENINGS OR OTHER IRREGULARITIES IN THE UNIT. STORMTRAP LIFTING INSERTS MAY BE RELOCATED TO COINCIDE WITH THE ACCESS OPENING OR THE CENTER OF GRAVITY OF THE UNIT AS NEEDED. STORMTRAP ACCESS OPENINGS SHALL NOT INTERFERE WITH INLET AND/OR OUTLET OPENINGS. ACCESS OPENINGS SHOULD BE LOCATED IN ORDER TO MEET THE APPROPRIATE MUNICIPAL REQUIREMENTS. STORMTRAP RECOMMENDS AT LEAST ONE ACCESS OPENING PER SYSTEM. RECOMMENDED PIPE OPENING SPECIFICATION MINIMUM EDGE DISTANCE FOR AN OPENING ON THE OUTSIDE WALL SHALL BE NO LESS THAN 1'-0". ALL OPENINGS MUST RETAIN AT LEAST 1'-0" OF CLEARANCE IN ALL DIRECTIONS FROM THE EDGE OF THE STORMTRAP UNITS. OPENING SIZE SHALL NOT EXCEED 0 36" OR 1 '-6" LESS THEN THE INSIDE HEIGHT OF THE UNIT. EXAMPLE: 3'-0" UNIT MAXIMUM OPENING= 0 1'-6". OPENINGS ARE NOT LIMITED TO THE ABOVE PARAMETERS BUT ARE RECOMMENDED. ANY OPENING NEEDED THAT DOES NOT FIT THE CRITERIA SHALL BE BROUGHT TO THE /TTENTION OF STORMTRAP FOR REVIEW. 2.2 SEE DETAIL "B'-' - ' l NOTES: I ,_ ,------I --.. I I ---=---. . •-. ' ' ) __ ', ;@_) (§) ~/ -• ' // l / ', ' / I ! // ! --< / '-, --~/ (~ C~) . ! PLAN VIEW \ /--------------_,,><._ ---------~-~---- I ELEVATION VIEW OUTSIDE WALL -----44'-2"------- ' i TOP OF FOUNDATIO~ ' L~\~ ' 36'-5" i MEETS: OPSS 1351.08.02 BNQ ASTM C-478-95a ASTM D-4101-95b ASTMA-615 AASHTO M-199 STAIR DETAIL ,: 'I ' " SIDE VIEW 1. DIMENSION OF FOUNDATION MUST HAVE 1'-0" OVERHANG BEYOND EXTERNAL FACE OF UNITS. I c~-~-2. DIMENSION OF STORMTRAP SYSTEM ALLOW FOR A 3/4" GAP BETWEEN EACH UNIT. 3. ALL DIMENSIONS TO BE VERIFIED IN THE FIELD BY OTHERS. 4. SEE SHEET 2 FOR INSTALLATION SPECIFICATIONS, /use /pn j,fotu iL,;, µ !UUUUt.sUUJli -~" crr.6UlUUtU$$U$ /u ,r / XO jcaic/ d_,;JfP /ll,$l$$UHH1fr, en_l -,t,leU$$-UU$$$S fmc.'icr/wf t1,1, ,,,,,-1 3.1 DETAIL "B" NOTES: STORM TRAP FOUNDATION #5 BARS@ 10" O.C. IN BOTH DIRECTIONS 1. 4,000 p.s.i.@ 28 DAYS, 5%-8% ENTRAINED AIR, 4" MAX. SLUMP. 2. NET ALLOWABLE SOIL PRESSURE GREATER THAN OR EQUAL TO 1,500 p.s.f. · 3. SOIL CONDITIONS TO BE VERIFIED ON SITE BY OTHERS. 4. 1 '-0" OVERHANG AROUND OUTSIDE OF SYSTEM. 5. REBAR: ASTM A-615 GRADE 60. BLACK BAR. POND LINER & GEOFABRIC INSTALLATION NOTES 1. FOUNDATION SLAB MUST BE FORMED WITH CORRECT DIMENSIONS, ALLOWING FOR A 1'-0" OVERHANG ON ALL SIDES. 2. CARE MUST BE TAKEN TO ENSURE THAT THE LINER IS NOT PUNCTURED THROUGHOUT THE INSTALLATION OF THE LINER, THE GEOFABRIC, AND THE STORMTRAP UNITS. 3. WHEN INSTALLING THE LINER, BOTH SIDES OF IT MUST BE COVERED WITH GEOFABRIC IN ORDER TO PREVENT PUNCTURE AND TO ENSURE THE WATERTIGHTNESS OF THE SYSTEM. A. INSTALL THE 1ST LAYER OF GEOFABRIC INSIDE THE FORMED AREA. BE SURE THAT YOU WILL HAVE A MINIMUM 1'-6" EXTRA TO FOLD ON TOP OF THE UNITS. REST FABRIC ON SIDES OF EXCAVATION WHILE INSTALLINGTHE SYSTEM. B. UNFOLD (IF REQUIRED) THE LINER TO ITS FULL WIDTH. (TAKE CAUTION AS TO CENTER THE LINER IN THE WIDTH WISE DIRECTION). THE LINER IS PREFORMED TO FIT THE STORMTRAP SYSTEM. C. UNROLL THE LINER TO ITS FULL LENGTH AND PLACE ON TOP OF THE GEOFABRIC. (AGAIN, TAKE CAUTION AS TO CENTER THE LINER IN THE LENGTH WISE DIRECTION). D. ENSURE THE LINER IS FLAT AND CENTERED TO ALLOW THE INSTALLATION OF THE 2ND LAYER OF GEOFABRIC. E. INSTALL THE 2ND LAYER OF GEOFABRIC ON THE POND LINER. BE SURE THAT YOU WILL HAVE A MINIMUM 1'-6" EXTRA TO FOLD ON TOP OF THE UNITS. REST THE FABRIC, LINER, FABRIC ON THE SIDES OF THE EXCAVATION WHILE INSTALLING THE SYSTEM . 4. CONTINUE FOUNDATION INSTALLATION AS DETAILED ON SHEET 02. 5. INSTALL SINGLETRAP UNITS PER INSTALLATION SPECIFICATIONS ON SHEET 02, AS DISCUSSED IN PRE-INSTALLATION MEETING. 6. ONCE INSTALLATION OF SINGLETRAP UNITS IS COMPLETE, THE LINER AND GEOFABRIC MUST BE LIFTED UP THE SIDES OF THE SYSTEM AND FOLDED OVER THE TOP OF THE SYSTEM TO A MINIMUM DISTANCE OF 1'-6". CARE MUST BE TAKEN TO ELIMINATE GAPS AND VOIDS BETWEEN THE SYSTEM AND THE LINER. 7. ANY EXCESS LINER IS TO BE DRAPED OVER THE TOP OF THE UNITS AND TAPED TO THE UNITS WITH JOINT WRAP. (IF REQUIRED, INSTALL RAINTARP ON TOP OF SYSTEM AND DRAPE OVERSIDES). PIPE CONNECTION 2.3 ;-0 6" HDPE OUTLET PIPE / 010" PRECAST OPEN!NG / INV=102.03 SPIV Ill Ill II II II V Ill Ill LAYOUT DETAIL NOTES: 1. DIMENSION OF STORMTRAP SYSTEM ALLOW FOR A 3/4" GAP BETWEEN EACH UNIT. 2. ALL DIMENSIONS TO BE VERIFIED IN THE FIELD BY OTHERS. 3. SEE SHEET 2 FOR INSTALLATION SPECIFICATIONS. V II II II SPIV Q 12" HDPE INLET PIPE /r--16" PRECAST OPENING / INV=102.28 / '--0 24' ROOF OPENING (TYP) ---- - ---- ---- ------------ . ' [ i QTY. I 6 ---- 6 4 2 ---- 2 0 ---- 0 12 3 TYPICAL PIPE ;1ENETRATION PROCEDURE (PROVIDED BY BEND TARP) 1. AFTER INSTALLATION OF POND LINER, CAREFULLY CUT HOLE TO ALLOW PIPE TO SLIDE THROUGH LINER. 2. SLIDE BOOT OVER PIPE AND PUSH UNTIL FLUSH WITH THE STORMTRAP UNIT WALL. 3. CAREFULLY CUT BOOT FLANGE BASE SO THAT IT EXCEEDS THE CUT IN THE LINER BY 4 TO 6 INCHES IN ALL DIRECTIONS. MAKE THE FLANGE SQUARE. 4. CLEAN LINER AND FLANGE. USE WATER, MEK, XYLENE, ETC ... DO NOT USE SOAP. 5. MARK A LINE AROUND FLANGE AND REMOVE BOOT. 6. PLACE 2" WIDE DOUBLE SIDED TAPE ON LINER (BOTTOM VIEW DRAWING). BE SURE TO OVERLAP AT CORNERS BY 1/4". LEAVE FILM LAYER ON TOP OF TAPE. USE A RAG TO FIRMLY PRESS DOWN THE TAPE AND WORK OUT ANY WRINKLES. 7. REMOVE TOP FILM LAYER OF TAPE. REPLACE BOOT AND PRESS DOWN ON TO 2" DOUBLE SIDED TAPE AND WORK OUT WRINKLES 8. PLACE JOINT WRAP COMPLETELY OVER EDGE OF BOOT, CENTERING ON THE SEAM. 9. PLACE BAND CLAMP ON BOOT RISER APPROXIMATELY 1" FROM TOP OF BOOT. TIGHTEN AND COVER WITH 4" SINGLE SIDED TAPE. STORMTRAP UNIT I ' ' I BILL OF MATERIALS -- PART NO. DESCRIPTION 5'-0" SINGLETRAP TYPEI TYPE I ------ TYPEII 5'-0" SINGLETRAP TYPE II 5'-0" SINGLETRAP TYPEIII TYPE Ill TYPE IV 5'-0" SINGLETRAP TYPE IV TYPEV 5'·0" SINGLETRAP TYPEV TYPE VI 5'-0" SINGLETRAP TYPE VI ------- TYPE VII 5'-C/' SINGLETRAP TYPE VII JOINT JOINT TAPE· 14.5' TAPE PER ROLL JOINT JOINTWRAP-150' WRAP PER ROLL -- DESIGN CRITERIA I /" -INSIDE GEOFABRIC LAYER " ;--PPL-24 POND LINER / / ;-OUTSIDE GEOFABRIC LAYER 1 ,1 / I , --------;:-J--- .· /// 1/ /_ // DOUBLE SIDED TAPE ' PIPE BOOT (PPL-30) SUPPLIED BY STORMTRAP DETAIL "D" // /// // I //NOTE: FOR ACTUAL PIPE LOCATIONS ~-/ AND INVERTS PLEASE REFER TO SHEET3,0 EXP. 6/30/11 INSIDE HEIGHT ELEVATION = 107.03 ALLOWABLE " (\ ,, Bl,_! IL T ' MIN GRADE= 108.19 /-\ ,_~) ALLOWABLE MAX GRADE= 116.17 ------SYSTEM INVERT= 102.03 R.:.E. STORMTRAP ~.XI-'. D1\ -E VOLUME= 6,542.00 C.F. / 0.15 A.F. RF \/lf-:\/l'lD BY "J'A"f 3"0RDAN I11SPEC-OR JATE w 11 'iPEEE lrlGl'lcFRlclG CE ~J F3 llvl u,J I 1 ' ' u . ------ C,Rl\O,r~:=:; PL.i\l\S FOR· POINS~TTIA PROPERTIES THE TIDES) --DETAILS ___ _ 'i._~5-01/IJUD 0502'/CIW 05-23 I APPROVE] A .x u.,. ~ti-Gl[~I K \/~ESXI" ---------- 03 I __ _J - ---------------/SENIOR CIVIL UICl_ciEH fF ~_120,,1 EXl'l',ES j/51/11 •~- 1/1\ A5-8UtLT . ' --------------D'v\N BY PEC .. __ I ·_:.p,~J[>{S}' -N 0: DRA:!/ l;!G,);-;O Cl.ii.TE INITl4L D.6.E ll'Jl 11,A.L D> TF INITl'.L CHKU fJY-·DE"(l... ,_..,.,).,. ', . ,, ,-,.,_. ,._,_. ,.'tr.~.'-~.; . -RE Sl'.)·.J D ~SCRIP Tl 01,1 CT 05-1 0 459....: BA rnGIN[LR C-F WOi?K OTHER .l\PF-'ROVA_ CITY ;\PPPOV.ll..L R\/"iND GY· -- AS-BUILT 051911 I I I I I 82 I I I I ---------~~---------~~-~-~ [ 12-..C~----60-----~~-24---~-----60------_______ 1_12~ ~---------------168---------------- PLAN VIEW 'f 8 _______________________ __,_ ' / .~o-4-ELEVATION VIEW ----------------------- I t:=l=====-60 ___ _ ' I 24 168 f------------ ~-~------------- Jc,-i-" "Jdak/ L~ p/a$UtS-UU$$$$$$t,ls1 cne111$$$1Ut1t!UtU / ,er /p,0jdat,,/c _'Jrpi$U,~$1tUU)F"e,,_too1,UHUUH>! ITc./Cc,1/)~$ $hi-mr:-,t 1 . PLAN VIEW ------ ELEVATION VIEW -11 •···· ,I ',: u C(J_) I 60 I --- ·r ~ I 06 68 60 ! 82 ----' ,,_ =ti I i ' 68 60 ! ------- [TYPE I UNITS UNIT HEIGHT (in.) 60 -----· I I I I __ ) - CUBIC STORAGE (C.F.) 451.5 WEIGHT (lbs.) ,,._ 13555 ~ ----------72-------'I 5 L SIDE VIEW ' ! TYPE Ill UNITS UNIT CUBIC WEIGHT' HEIGHT; STORAGE (lbs.) (in.) (C.F.) I ' ..... -. 60 I 435 16025 s t - ;,,; ----- [12 --------- I I I I I ~ 72------J 5 '---- SIDE VIEW I I ---I I 60 I 127 84 PLAN VIEW --- j '1) ':rt 8 - ~-------- 60 ELEVATION VIEW 05 ~, ------------84------- , ! 1 4 -12--.-- 1 ~----60 - --··1 - L _______ J 08 PLAN VIEW ELEVATION VIEW OUTSIDE WALC- ~------------- I <Y 82 68 i I ' 12 ~ I - UNIT HEIGHT (in.) 60 I I ' 7 I ' ' ' ' I 82 8 7 ! 68 60 CUBIC STORAGE (C.F.) 212.5 WEIGHT (lbs.) 8685 t 12 I 60 84 PLAN VIEW ---'f T L ___ - I 12] i ' -"-f I 8 ' ' ' - --------- 72 --- SIDE VIEW fli - I I i ' ------ I -------------~ ' 07 tr - - J s l~----72------J s L SIDE VIEW ------ I TYPE V UNITS I UNIT HEIGHT (in.) 60 CUBIC STORAGE (C.F.) 204.5 lwE1G~1 ' (lbs.) 9920 ELEVATION VIEW INSIDE WALL 60 ' i I 82 68 I TYPE IV UNITS Q -.. --- I I UNIT CUBIC WEIGHT HEIGHT STORAGE (in.) (C.F.) (lbs.) 60 204.5 9920 ' ··---------7 I I I ------------~- J s -I ------n---___,I s L SIDE VIEW R.C.C REVIEVv'EO BY: "SA'< :Y6RDAN 11,IS"'ECTOR EXP. 06/30/11 ElUIL T iJ,4 ff DATE -----------+---+--+---+---I w EI-IGl'IEERll,G Dl'?e.RTIJl[I-IT f------+---+----------~==='-==================-:_'---==='. SHEETS 'i 7 ; , _ _) f------+----1---------------+---l---+---+-----j GRADlf\JG rLA\JS '-CR: f------t-----1---------------+------+----+-----i ------f----+- f-----+---- --II\-. AS-=8U-~ll=T~----------+---I--_------------j-----j DA--;-E l:'JITIAL lHG!IIEER C·F WORK C:iTHER APPROV.41_ CITY A_=>PRO\/AL 0'0/\ f?Y: CHf<D E:Y• ~\/1/'/D BY POINSl;TTIA PROPERTIES ( THE TIDES) REC PF:OJECT t-lC l) £:/'L. CT 05-10 469-SA AS-BUILT 05191'1 WALL DATA WALL NO. LOT NO. SQUARE FT. WALL TYPE 1 2 185 (C-6l 2 3 370 (C-Gl 3 2 & 3 84 (C-4l • 4 4 318 (C-6l .. • ,· ,. .. . ' 6 5 219 <C-6) 7 6 184 DETAIL 2, SHT. 13 8 6 395 DETAIL 3, SHT. 13 9 6-11, 13 & 14 5200 DETAIL SHT. 12 10 6 400 DETAIL 4, SHT. 12 11 6 517 DETAIL 4, SHT. 12 12 6-11, 13 & 14 4490 DETAIL SHT. 12 13 7 82 (C-2l 1 4 27 257 (C-6l 1 5 27 134 (C-4l 16 26 452 (C-6l 1 7 23 193 (C-6) 1 8 24 330 DETAIL 1, SHT. 13 19 25 273 (C-6) 20 25 & 26 1047 (C-6l 21 20 & 21 540 (C-6) 22 21 82 CC-4l 23 20 & 21 213 DETAIL 1, SHT. 13 24 20 236 DETAIL 1,SHT.13 25 19 & 20 714 DETAIL 1, SHT. 13 26 19 205 (C-6l 27 15 & 16 720 (C-6) 28 11 & 13 54 (C-4) 29 21 128 <C-4l 30 23 80 (C-4l 31 24 62 CC-4l 32 27 150 (C-1 l 33 24 202 DETAIL 1,SHT.13 34 6 34 (C-6l IZ IC K 5620 FRIARS ROAD SAN DIEGO, CA 92110 619.291.0707 (FAX)619.291.4165 ADDITIONAL COMMENTS NO PERMIT NEEDED NO PERMIT NEEDED STRUCTURAL CAL CS. INCLUDED STRUCTURAL CALCS. INCLUDED STRUCTURAL CAL CS. INCLUDED STRUCTURAL CAL CS. INCLUDED STRUCTURAL CALCS. INCLUDED STRUCTURAL CALCS. INCLUDED NO PERMIT NEEDED STRUCTURAL CALCS. INCLUDED STRUCTURAL CAL CS. INCLUDED STRUCTURAL CAL CS. INCLUDED NO PERMIT NEEDED STRUCTURA~ CALCS. INCLUDED NO P~RMIT NEEDED J-14826C 0 ~ · N E rlckengineering, com <9 San Diego Riverside -Orange -San Luis Obispo -Bakersfield -Sacramento -Phoenix -Tucson R• \1 4826\G.--od Ing\ 1482•Lgr-d. 1 0. dgn \ \enc .r I b 1 \R I ckStondords \!lent I sy _2006\workspocs\pro Jee ts\CorpStds _2005 -SD\ Ip I ot\CorpSt<;ls_2005 _SD. pen 17"MAR-201l 08119 SHEET NO. 4 4 4 4 4 4 & 5 4 4 4 & 5 4 4 4 4 5 5 5 4 5 5 5 5 5 5 5 ) 5 5 5 5 4 5 4 •,, ~, ~ \~l ,~ i% ' ; !'-· ENGINEER OF WORK RICK E GINEERING CO. ~UILT" REVIEWED BY: J"AY 'J" OR~ INSPECTOR DATE 1'l../l 'I.-/ I? DATE [SHm7 CITY OF CARLSBAD I SHEETS I f-----1---t--------------~-t-----t---r---,,-, L1Q_j ENGINEERING DEPARTMENT 13 f-----1---t---------------~t-----t---r---,,-, ;::G:;RA=;D~IN::G;:_';;P=LA::;N::;S~FO~R~,::='::=:'::::::'=:=::::::==:=='..'.::::=~ AS· /!,UJLT DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL POINSETTIA PROPERTIES OWN BY: REC CHKD BY, Q 2 F'- RVWD BY: (THE TIDES) V 05-01/PUD 05-08/CIP 05-2 PROJECT NO, DRAWING NO. CT 05-10 469-SA UI 05191'1 GENERAL REQUIREMENTS All material and workmanship shall comply with the following: 1. These General Requirements unless otherwise noted on plans or specifications. 2. California Building Code, 2010. 3. All applicable Local, State and Federal Codes, Ordinances, Laws, Regulations and Protective Covenants governing the site of work. 4. Standard Specifications of ASTM as noted herein are required by the Building Code or C.B.C. 2010. 5. In case of conflict, the more stringent requirement shall govern. 6. On site Verification of all dimensions and conditions shall be the responsibility of the contractor and sub-contractors. Noted dimensions take precede11t over scale· of drawings. 7. Engineer or architect of record is to be notified immediately by the contractor should any question arise pertaining the working drawings and/or specifications. 8. No deviations from these requirements and structural details shall be made without the written approval of Gouvis Engineering Consulting Group. Approval by the inspector does not constitute authority to deviate from plans or specifications. ' 9. The design, adequacy, and safety of erection bracing, shoring, temporary supports, etc., is the sole responsibility of the contractor, and has not been considered by the architect or Engineer. The contractor shall provide the necessary bracing to provide stability prior to the application of the aforementioned materials. Observation visits to the site by the architect or structural engineer shall not imply the assumption of any responsibility in this regard. The builder has requested, contracted with and is compensating Gouvis Engineering Consulting Group for the limited services of providing the minimum structural engineering drawings required, when combined with the other builders consultants drawings, to obtain a building permit for this project. These drawings are not intended to, nor do they, detail all conditions, identify all materials, or define or limit the scope of work required to complete the project. The builder has requested, accepts, and represents that he will select all materials and manufactures, qualify and select all subc·ontractors arid installers, direct all ways and means of construction, and provide all additional information, above and beyond these drawings, required to complete the project in conformance with all governing agencies and the work will meet or exceed accepted industry standards. REINFORCED CONCRETE GENERAL 1. All reinforced concrete materials and construction shall conform to chapter 19, C.B.C. MATERIALS 2. Cement shall conform to C.B.C. 1903 of C.B.C. and shall correspond to that on which the selection of concrete proportions were based. 3. Concrete aggregates shall conform to C.B.C. 1903 4. Use type V cement for concrete in contact with soil containing sulfate. (min. fc =4500 psi, 28 days). Refer to section 1904 of Building Code for special exposure conditions as required by Soils Engineer & see Carrison Engineer's recommendations for concrete exposed to corrison. 5. Reinforcing steel shall conform to ASTM A615. Grade 40 for sizes #3 and #4 and grade 60 for sizes #5 and larger. 6. Dowels shall be equal in size and spacing. STRENGTH 7. Concrete shall be proportioned to provide a minimum compressive strength, f'c, equal to 2500 psi .(28 days), unless noted otherwise. 8. All reinforcing, dowels, holdowns, and other inserts shall be secured in position and approved by the local building official prior to the pouring of any concrete. Min. concrete cover for reinforcing: a. Concrete, placed against earth not fomied -3" b. Concrete formed or troweled -2~ c. Walls and curbs - 1 1/2" d. Slab on grade -at center CONCRETE MASONRY GENERAL 1. All concrete masonry materials and construction shall be in accordance with Chapter 21, California Building Code. MATERIALS 2. All materials making up finished concrete masonry construction shall confom, to standards required by Sec. 2103, C.B.C. 3. 4. Mortar shall be type M or Sas applicable and shall be proportioned per C.B.C code Table 2103.8.1 & 2103.8.2 and in conformance with ASTM C270, mortar for units masonry. Grout shall have ingredients proportioned per Table No. 2103.12 of, C.B.C. and in conformance with ASTM C476 grout for masonry and shall attain a minimum compression strength at 28 days of 2000 psi or the required compression strength of the concrete masonry units, whichever is greater. 5. Concrete masonry units for load bearing systems may be concrete brick as specified by ASTM C55, Specifications for Concrete Building Brick. Grade N concrete bricks are for use as architectural veneer and facing limits in exterior walls. Grade S concrete bricks are for general use where moderate strength and resistance to frost action and moisture penetration is required. STRENGTH 6. The specified compressive strength of masonry, fm, shall be 1500 psi, unless noted otherwise. If higher fm is noted, it shall be verified by prism tests as required in section 2105. 7. Reinforcing steel shall confonn to ASTM A615. Grade 40 for sizes #3 and #4 and grade 60 for sizes #5 and larger. FOUNDATION Soils Foundation engineering has been predicated on data and recommendations contained in soils report by EARTH-STRATA, INC., SOILS REPORT NO. 10707-1 DA, DATE: 05/11/10. This report is considered part of calculations and construction documents and is to be adhered to in all of its recommendations and requirements. Verify minimum foundation depth, width, reinforcing steel and additional expansive soil requirements with valid soils report and if they are any more restrictive. then they shall supersede the Gouvis Engineering minimums. Soil engineer should review and approve all retaining walls prior to construction. DESIGN CRITERIA: ACTIVE EFP (LEVEL\ = 40 PCF' ('CAN BE APPLIED ON UPPER RET. WALL) ACTIVE EFP (2:1) = 81 PCF PASSIVE EFP = 350 PCF SOILS DENSITY = 125 PCF BEARING CAPACITY= 3,000 PSF U.= 0.36 fc = 4,500 PSI (see note #4 under reinforced concrete) 1. U.N.O. all cells containing reinforcing steel shall be grouted solid. 2. All portion of wall retaining shall be grouted solid. 3. All footing shall be poured on undisturbed ground or undisturbed engineered compacted fill. A field soil memo is required from a representative of the geotechnical consultant for soil inspection of the footing excavation to confimi that the footing is excavated into suitable bearing material. 4. Wall shall be laid true and plumb. 5. Provisions shall be made for adjoining construction. 6. All laps and splices shall be 48 bar diameter min. 7. All construction shall be done in accordance with applicable sections of the 2010 CALIFORNIA BUILDING CODE and A.C.I. standards 318-05. 8. All bars shall be bent cold. 9. Contractor shall verify compatibility of design with existing conditions prior to placement of footing steel. 10. Backfill shall be per soils engineer's recommendations. 11. Subdrain shall be 4" perforated PVC schedule 40 pipe with 1 CF/LF of 3/4" crushed rock or equivalent wrapped in mter fabric. The filter must overlap 12~ at ends of the filter. Outlet subdrain to the curb opening. 12. Waterproof back of all the retaining walls w/2 coats of asphaltic emulsion per manufacturer's specifications. 13. Slab control joints shall be placed at an angle points and a maximum 12'-0" o.c. 14. Backfilling shall not be permitted until at least 7 days after the walls are built and fc has reached min. 2500 psi and grout has obtained min, 2000 psi compression strength. 15. Retaining walls are not designed for surcharge of paving equipment. Equipment must be kept back from top of the wall minimum distance equal to wall height. 16. For curved portion of the walls, footing reinforcing shall be placed radially, and spacing measured along the centerline of the masonry wall. 17. Outlet of any surface drainage pipe inlo the subdrain system is absolulefy prohibited. 18. Concrete cylinder tests From project pour, in accordance with the C.B.C. shall be submitted for review and approval by the project soils engineer and the local jurisdictional authorities, prior 10 any backfilling. 19. Step footing shall be in even block increments. 20. Footings shall be poured continuously. . . SPECIAL INSPECTION: 1. In addition to the regular inspection, the Following items 'Mil also require special inspection in accordance with Sec.1704 of the Building Code. 2. Soils compliance prior to 1he foundation inspection, pre-stress foundation, high strength steel and concrete. 3. All inspection and tests shall be performed by a qualified testing agency retained by the owner. 4. The special inspector shall be qualified and approved by the building department and acceptable to the architect. 5. The special inspector shall observe work assigned for conformance to the.approved design drawings and specification. 6. The special inspector shall furnish Inspection report to building department, engineer and architect of record. Copies of the report shall be available at the job site at all time. 7. Final reports for all inspections and testing must be provided by the special inspector. Final reports shall document completion of all inspection and correction of all noted discrepencies. a. The duties of special inspector shall be in conformance with the requirements of section 1704 of the California building code the latest edition. 9. Contractor shall be responsible for all expenses due to any premature notification of inspection which results in additional site visitS. 10. Failure of notification by the contractor for inspection on a timely basis may result in complete removal and replacement of all work performed at contractors expenses. Site visits by the structural engineer do not constitute an inspection. Special inspection required for the following items: SPECIAL INSPECTIONS AND VERIFICATIONS BY A SPECIAL INSPECTOR ARE REQUIRED FOR CONCRETE CONSTRUCTION AND SPECIFIED IN THE FOllOWING TABLE SPECIAL INSPECTION TABLE FOR CONCRETE CONSffiUCTION (ONLY APPLICABLE IF THE STRUCTURAL DESIGN OF FOOTING IS BASED ON fc > 2500psi) SEE NOTE 114 UNDER REINFORCED CONCRETE. - . VERIFICATION & Not Continuous Referenc.a IBC Period<alli INSPECTION TASK Applicable durtng task durilg las Standard Reference listed listed 1.lnspection of reinforcing steel and placement. I a. Placing of reinforcing ✓ steel b. Sampling and testing of ✓ steel ~mill reports & ACl318: ident' cation of steel) 3.5,T.1-7.7 c. lnspectioh of installation ✓ of rebar couplers d. Reinforcing steel sizes, spacing, splices, clearance and concrete cover per construction document ✓ 2. lnspectian of reinforcing steel welding in the following items: AWSD1.4 a. Verification of weldability ACI 318: 3.52 of reinforcing steel other ✓ than ASTM A706 3. Inspect bolts to be installed ' in concrete per structural drawing during placeme_nt ✓ 1911.5 of concrete where allowable loads have been increased 4. Verifying use of required design mix a. Method of proportioning ✓ ACI 318: 1904.2.2 b. WIG ratio ✓ Ch. 4, 5.2-5.4 c. Cement type ✓ d. Strength ✓ 5. At the time fresh concrete is sampled to fabricate ASTMC 172 specimens for strength tests, perform slump and air content ✓ ASTM C31 tests, Determine the ACI 318: 5.6, 5.8 temperature of the concrete - for shortcreta construction 6. Inspection of concrete for proper application techniques. (conveying & depositing) ✓ ACI 318: 5.9, 5.10 7. Inspect formwork for shape, location and dimensions of the ✓ ACl318:6.1.I concrete member being formed PRIOR TO THE CONSTRUCTION OF CMU STRUCTURES VERIFICATION OF MASONRY MATERIALS BY THE SPECIAL INSPECTOR SHALL COM Pl Y WITH THE FOLLOWING TABLE: 1. Certification of compliance indicating that masonry materials used comply the code and contract documents. 2. Verification of fm prior to construction. SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR THE CONSffiUCTION OF GMU STRUCTURES ARE REQUIRED AND SPECIFIED IN THE FOLLOWING TABLE: SPECIAL INSPECTION TABLE FOR CMU STRUCTURES FREQUENCY OF INSPECTION REFERANCE FOR CRITERIA INSPECTION TASK Nol vVnlinuous Perlooi<al~ IBC "" ~· Applicable durilg task di.Jing 'tas Section 530/ASCE 530.1/ASCE listed listed 5/TMS402 6/TMS602 1.As masonry construction begins,the following shall be verified to ensure compliance: a. Proportions of site ✓ Art, prepared mortar. 2.6A b. Construction of ✓ Art. mortar joints. 3.3B c. Locatiora of reinforce-Ari. ment, connectors and ✓ 3.4, l.6A anchorages. 2. The insp0ction shall verify. a. Size and location of ✓ Art. structural elements 3.3G b. Type, size and location of abchors, including Seo other details of ✓ l.2.2[e), anchorage of masonry 2.1.4, to structural members, 3.1.6 frames or other construction. c. Specified size, grade ✓ Sec. Art. and type of reinforce-1.13 2.4, 3.4 ment. d. Welding of reinforcing Sec. ✓ 2.1.10.T.2, bars. 3.3.3.4~1 e. Protection of masonry Sec. during cold weather ✓ 2t04.3, Art (temp. below 40' F) I.BC, 1.8D or hot weather 2104.4 (temp. above 90' F) 3. Prior to grouting, the following shall be verified to ensure compliance: a. Grout space is clean. ✓ Art. 3.20 b. Placement of rein-Se<, Art. forcemdnt and ✓ con~e ors and 1.13 3.4 anc oragas. c. Proportions of site-✓ Art. prepared grout. 2.68 d. Construction of ✓ Art. mortar joints. 3.3B 4. Grout placement shall be ve~fied to ~nsure Art. comp iance with code ✓ and construction i 3.5 document provisions. 5. Preparation of any required grout specimens, Sec. Art. mortar specimens and/or ✓ 2105.2.2, 1.4 prisms shall be observed. 2105.3 6. Compliance with required inspection provisions of the construction docu-✓ Art. ments and the approved 1.5 submittals shall be verified. For SI: ·c = ('F-32) /1.8 SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR EXISTING SITE SOIL CONDITIONS, Fill PLACEMENT & LOAD BEARING REQUIREMENTS SHALL BE PERFORMED PER THE FOLLOWING TABLE. SPECIAL INSPECTION TABLE FOR EXISTING SITE SOIL CONDITIONS f -'"""'-""'"'~ o,vT ~~·" PERIODICALLY APPLICABLE DURING TASK DURING TASK Verify materials below footing are adequate to ✓ achieve the design bearing ,capacity per soils report. I 2.iverify excavations are ' 'extended to proper depth ✓ ,& have reached proper ~material per soils report. 3.iPerform classifica1ion ! & testing of controlled ✓ : fill materials per soils report. , 4. Verify use of proper ! materials, der1sit1es & lift !thicknesses during place-✓ i ment & comraction of controlled fil per soils re...,,rt. ' 5_! Prior to placement of controlled fill, observe subgrade & verify that ✓ site has been prepared · properly per soils report. . Exception -Special inspection is not required during placement of controlled fill having a total depth of 12 inches or less. 90' BEND BEND + , , 48(d) • IN CONCRETE 1 --148(d) MASONRY (U.N.O.) K~~} + WIRE TIE END LAP SPLICE (!) z 0 z en ::; z ~ w " w 5 0 ,,. __ ~~1-TIE OR HOOK ~--z;o ./ii (!) z 0 z en ::; z ~ w " w 5 0 STIRRUP 05124 4(d) OR 180' BEND R= 31dl FOR lfJ THRU #8 R=4 d FOR#9THRU #11 R= 5 d FOR #14 THRU #18 • INCREASE LENGTH BY 30% FOR TOP BARS (HORIZONTAL BARS SO PLACED THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW, EXCLUDE WALLS) CROSSTIE D= 4(dl FOR #3 THRU #5 D= 6(d FOR #6 THRU #8 NOTES: -PUT CROSSTIE W/ EACH STIRRUP ALT. 135' BENDS -ALL BENDS SHALL BE MADE COLD T,YP. REINFORCING DETAILS , 48 db 24"MIN. 1.5 "$" D5115RW STEPPED FOOTING FrG. REIN'F. PER HAIL "S" SHOULD BE MAX 18~ "D" IS OVERALL DEPTH OF FTG. BEND REBAR$ IF REQUIRED & LAP MIN. 48 BAR DIAMETERS REINFORCEMENT TO MATCH FOUNDATION DETAILS. 1 2 CAULKING DETAIL CONTROL JOINT AT TOP OF WALL I TYPICAL CbNTROL JOINT CONTROL JOINTS SHALL BE SPACED 20'-0" MAX. 4 7 3 5 6 7 DEPTH OF CAULKING SHALL BE 1/2" MIN. J.____1 3/8" TO 1/2" HEAD JOINT 1. CONCRETE BLOCK 2. SEE DETAIL ABOVE 3, CONTROL JOINT ASPHALT IMPREGNATED FILLER WITH SEALANT (TYP.) FROM TOP OF THE WALL TO THE TOP OF FOOTING PER MANUFACTURER'S SPECIFICATION. 4. FOOTING 5. ADDITIONAL VERTICAL BAR ON EACH SIDE OF CONTROL JOINT 6. TERMINATE ALL NON- STRUCTURAL REINFORCING 2" FROM CONTROL JOINT 7. CONT. TOP BARS/CHORD BARS PER WALL SECTION. 4 8. SEE CAULKING DETAIL ' -9. BACKER ROD +-_:__.c._~~-~--'---~1~~'-' ~-_:_' __ ...Aj'-------1 4 05125 TYPICAL CONTROL JOINT DETAIL CORNER 1. ADDITIONAL #5 VERTICAL BAR PLACED AT CENTER OF WALL 12" MIN. INTERSECTION TYPYCAL WALL CORNER DETAIL D5127N1 DATE INITIAL EMGINEER OF \/ORK REVISION DESCRIPTION 3 4 NOTE, 48 BAR 4' 18" MIN. LAP 48 BAR 4> 24" MIN, LAP 48 BAR 4> 24" MIN. LAP r I I THREE VERT HALL / REINF FOUR VERT HALL / REINF----·-~ DOUBLE CURTAIN REINF. 48 ElAR 4> 48 BAR 4> -------~-- 24" MIN. LAP 24" MIN. LAP ONE VERT HALL REINF. SINGLE CURTAIN REINF. BENT DOHELS SIZE TO MATCH TYP. REINF. CONG. FTG./WALL REINF. 48 BAR 4> f24" MIN. LAP I 5 CAULKING DETAIL " CONTROL JOINT AT TOP OF WALL I TYPICAL CONTROL JOINT CONTROL JOINTS SHALL BE SPACED @ 20'-0" MAX. 10 ' " " ' 0- WALL ELEVATION > " ' ' <l ' ,, ~ ,, . " <l ', " '<l • ' ' ' ,, ' •, ' ' ·i' ' ' .t ' ' ' ' 4! ! ; ' ' ' ' ' 5 6 ' ) / ~ / .... <'.! _,, J ' ', ' ' ' ", 7 1. CONCRETE WALL 2. SEE DETAIL ABOVE 3. CONTROL JOINT ASPHALT IMPREGNATED FILLER WITH SEALANT (TYP.) FROM TOP OF THE WALL TO THE TOP OF FOOTING PER MANUFACTURER'S SPECIFICATION. 4, CONCRETE FOOTING 5. ADDITIONAL VERTICAL BAR ON EACH SIDE OF CONTROL JOINT 6, TERMINATE HORIZONTAL REINFORCEMENT 2" FROM CONTROL JOINT 7. CONT. TOP BARS/CHORD BARS PER WALL SECTION. 8. SEE CAULKING DETAIL 9. BACKER ROD 10. VERT. & HORZ. REINF. SEE SECTION WALL 4 TYP. CONC. RET.-WALL' CONTROL JOINT DETAIL ENGINEER [JF \./[JRI< GDU\/IS E~!GINEERil~[1 HUAN NGUYEN R C.E. 54238 DATE 11 AS R,C,E, E/P, REI/IE'wED C! lflSPCCTOk RETAINING VALL PLAl--i~ FlJR 1 POINSETTIA (THE PROPERTIES TIDES) DAT[ ~ATE 6 V 05-01/PUD 0508/CDP 05-11 APPROVED, DATE INITIAL DATE INITIAL THER WPROVAL CITY APPR[JVAL D \J 1--i B Y , --,2,'.:s:.f,.rt-=--..----- CH:< D BY, ...,~ RI/\JD BY, PROJECT NO. CT 05-10 DRA\-/JNG rm. 469-BA UJL.T 05191'1 DEEPENED UPPER RET. WALL FTG. • -ro BE AT THIS IE\71':C --' STEM (Ft) H A B 6'-9" 12· 3'-8" MAX. I FOUNDATION (Ft) C D E 4'-9' 3•.9• 12" ' ' ~CABLE RAILING INSTALLED BY OTHERS, SEE CAL TRANS STANDARD (NEW CONSTRUCTION) AS A GUIDELINE. 2 3 }-+:lol 2" GLR 4 >--+_,, ~----{ 7 7 9 1. (2) #4 CONTINUOUS 2. 10" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 5. #5 @>. 16" 0.C. VERT. AND #4 @). 16" O.C. HORIZ. U.N.O. 6. C'OMPACTED BACKFILL APPROVED BY SOILS ENGINEER 7. REFER TO SOILS REPORT FOR WATERPROOFING & DRAINAGE SYSTEM. 8. 2X6 CONT. SHEAR KEY. 9. CONG. FOOTING, (F'c = 4500 PSI, TYPE V CEMENT). 10. #4@).16" O.C. T & B. 11. ADIJ#5 12. CONG. KEY PER SCHEDULE 13. 14. Z-BARS PER SCHEDULE NOTES: -WATERPROOFING, EXTENT 1--t---{ 14 OF BACKFILL, BACKFILL MATERIAL & DRAINAGE REINFORCEMENT X1 Y1 z #5@16"0.C. #6@8"0.C. 114@16"0.C. TOP&BOTT. SYSTEM TO BE REVIEWED & APPROVED BY GEOTECHNICAL ENGINEER. -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. ... DEEPENED FOOTING UNTIL THE FOOTING MEET DAYLIGHT REQ. PER SOILS REPORT. USE 12" MIN. IF NO DEEPENED FOOTING NEEDED. -SPECIAL INSPECTION REQUIRED FOR CONCRETE. UPPER RETAINING WALL#11 SECTIONS 8-8, C-C, D-D, E-E NOTTO SCALE 2 I 6 5 0-~~: " 7 ·2'!_ .. "')\ . ;,-.cu,: N 20 STEM (Ft) FOUNDATION (F1) H A B C D E F G 6'-0' 1·-2· T-2" 10'-0" 3'-0" 1'-0" 6'-0" 1 '-0" MAX. r·1 I '~CABLE RAILING I INSTALLED BY OTHERS, i SEE CAL TRANS STANDARD (NEW CONSTRUCTION) AS A GUIDELINE. GLR ' . --® lSI ~ "' ,n . >< "' 8 .. ., 2" GLR .. 12 REINFORCEMENT X1 Y1 X2 #5 @16"0.C. #6@8'0.C. #5@16"0.C. EACH FACE 1. \2l #4 CONTINUOUS 2. 0" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE LAP INTO WALL BELOW AS SHOWN. 5. (2) #5 CONTINUOUS 6. 16" CONCRETE RETAINING WALL, (F'c = 450D PSI, TYPE V CEMENT). 7. X2-BARS PER SCHEDULE 8. Y2-BARS AT INSIDE FACE PER SCHEDULE, DOWEL INTO FOOTING AS SHOWN W/ STD. HOOK. 9. #5 till 16" O.C. VERT. AND #4 @). 16" O.C. HORIZ. U.N.O. ::l 10. C'OMPACTED BACKFILL ~ ~ APPROVED BY SOILS ENGINEER o > 11. REFER TO S_OILS REPORT f-0 FOR WATERPROOFING f-z & DRAINAGE SYSTEM. ::J 8 12. 2X6 CONT. SHEAR KEY. LL ,: 13. CONG. FOOTING, -;[_ Q (F'c = 450D PSI, TYPE V CEMENT). O F 14. #4 t<ll 16" o.c. T & B. 1-, 15. ADI) #5 "' 16. CONC. KEY PER SCHEDULE 17. 18. Z-BARS PER SCHEDULE 19. SUBGRADE PREPARATION PER SOILS REPORT. 20. #5@>.16" O.C. AT OUTSIDE FACE, DOWEL INTO FOOTING AS ,: ::l SHOWN WI STD. HOOK. Q~ I . 1-0 'Z ;<: 0 0 Y2 #7@8'0.C. z -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. #5@16"0.C. TOP& BOTT. LOWER RETAINING WALL#10 SECTION 8-8@ 8IORETENTION NOTTO SCALE 4 1'-0" MIN. I '·V; PER SOILS REPORT (5'-0" MIN.) STEM (Fl) FOUNDATION (Ft) H A B 6'-0' 12' 2•-9• .. I I .. 1. (2) #4 CONTINUOUS 2. 8" SOLID GROUTED CMU .. 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE AT CENTER OF WALL, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 5. #4@16" O.C. TOP & BOTT. 6. CONG. FOOTING (F'c = 4500 PSI, TYPE V CEMENT). 7. #4@ 16"0.C. T & B. 8. ADD#S 9. SUBGRADE PREPARATION PER SOILS REPORT. 10. FOOTING@). ADJACENT STRUCTURE/BUILDING 11. REFER TO SOILS REPORT FOR WATERPROOFING & DRAINAGE SYSTEM. 12. GLASS VIEW FENCE PER ARCHITECT, INSTALLED PER MANUFACTURER. -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION . • , .. DEEPENED FOOTING UNTIL THE FOOTING MEET DAYLIGHT REQ. PER SOILS REPORT. USE 12" MIN. IF NO DEEPENED FOOTING NEEDED. -SPECIAL INSPECTION REQUIRED FOR CONCRETE. REINFORCEMENT X1 Y1 114@24' o.c. #5@16"0.C. CMU SOUND WALL SECTIONS B-8, C-C, D-D, E-E NOTTOSCALE 1 STEM (Fl) H A 6'·9" 1'-2' MAX. ; PER SOILS REPORT (5'-0" MIN.) I FOUNDATION (Ft) B C D E 7'-9" 10'-0' 3'-0" 1'-0'' 3 }----8>4· 10" ., ~ 4 f----+---J ., CABLE RAILING INSTALLED BY OTHERS, SEE CAL TRANS STANDARD (NEW CONSTRUCTION) AS A GUIDELINE. 1 '~0" 2" GLR ·4" " lSI 11 ~ "' II] i;J 8 .. 2" ,. GLR ' '.,-12 13 11 1. (2) #4 CONTINUOUS 2. 10" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE LAP INTO WALL BELOW AS SHOWN. 5. (2) #5 CONTINUOUS 6. 16" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 7. X2-BARS PER SCHEDULE 8. Y2-BARS AT INSIDE FACE PER SCHEDULE, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 9. #5@ 16" O.C. VERT. AND #4 , @>. 'IT;" 0.C. HORIZ. U.N.O. _, 10. C'OMPACTED BACKFILL w < APPROVED BY SOILS ENGINEER al s 11. REFER TO SOILS REPORT 0 cj FOR WATERPROOFING >-z & DRAINAGE SYSTEM. tij 00 12. 2X6 CONT. SHEAR KEY. w 13. CONG. FOOTING ~ B (F'c = 4500 PSI, TYPE V CEMENT). a. I 14. #4@ 16" 0.C. T & B. 01-15_ ADD#5 f-b 16. CONG. KEY PER SCHEDULE .. 17. _, " _, Q~ :c . f-0 ' z ';" 0 0 18. Z-BARS PER SCHEDULE 19. SUBGRADE PREPARATION PER SOILS REPORT. 20. #5@16" 0.C. AT OUTSIDE FACE, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. ... DEEPENED FOOTING UNTIL THE FOOTING MEET DAYLIGHT REQ. :'" PER SOILS REPORT. USE 12" MIN. +----D __ ,,_ E __ ,,_ ____ F ____ _,, IF NO DEEPENED FOOTING NEEDED. +----------C --------~---SPECIAL INSPECTION REQUIRE FOR CONCRETE. REINFORCEMENT F G X1 Y1 X2 Y2 z 6'-0" 1'-0" #5@16'0.C. #6@8"0.C. #5@16'0.C. #7@8"0.C. #5@16"0.C. EACH FACE TOP&BOTT. LOWER RETAINING WALL#10 SECTIONS C-C, D-D, E-E NOTTO SCALE 3 SEE DETAIL 3/RW-2 FOR LOWER CONG. RET. WALL ER GRADING PLAN SHEET 3 SECTIONS C-C, D-D, E-E SEE DETAIL 4/RW-2 FOR LOWER CONC. RET. WALL PER GRADING PLAN SHEET 3 SECTION B-B @ BIORETENTION 5'-0" MIN. 5'-0" MIN. STACKED RETAINING WALL FOR SECTIONS 8-B, C-C, D-D, E-E BASED ON SHEETS 3 OF RICK ENGINEERING CO. NOTTOSCALE AS-8Utlr ISEE DETAIL 1/RW-2 FOR CMU SOUND WALL Uillf.---1IPER GRADING PLAN SHEET 3 SECTIONS B-B, C-C, D-D, E-E ENGINEER OF \,/ORK GOLJ\/IS E~JGI~JEERI~IG HU.AN NGUYEN R.C.E. 64238 DATE R.C.F. REVJE\,/[D BY, EXP RETMNWG VIALL PL/',NS f-QR, POINSETTIA PROPERTIES (THE TIDES) V 05-01/PUD G508/CDP GS-23 ~PPR□VED~-...,_.£ ,·_1J,,, 1fWt.· ·-Gc[~-1 X. V~ES.<I , ;A?-"-· ·-• . .4 I. ·W "·¢/ SENIOR CIVIL E~IGI~JEER PE 41204 EXPIRES 3/31/13 .DI".\ IE PROJECT t:□. DR~.\-/mG fl □. DATE INITIAL NG!NEER OF IJDRK DATE !CIITIAL DATE INJTJAL DVN BY GE CHKD BY, I),> /1.-::. RV\/D BY, c-:-05 10 469-BA REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL GS 1911 I L ' STEM (Ft) H 4'-0" MAX. A ,,',' ·i; .,~ < 10" \t \t 1 1 ' . /)-~-" -,,--F "~t:~c ;f D +-----C ____ ,, FOUNDATION (Ft) B C D E 1'-0" 1 '--0" 3'-0' 6" 1·-0· RETAINING WALL #8 ll'l F G 1'-6" 6" ! j SEE SECTION B-B ON CIVIL DRAWING FOR MORE INFORMATION. REINFORCEMENT X1 Y1 z #5@16"0.C. #5@16"0.C #4@16"0.C. · TOP &BOTT. 1. (2) #4 CONTINUOUS 2. 10" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE AT CENTER OF CONCRETE STEM, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 5. 6. 7. 8. 9. #5@ 16" O.C. VERT. AND #4 @ 16" O.C. HORIZ. U.N.O. 10. COMPACTED BACKFILL APPROVED BY SOILS ENGINEER 11. REFER TO SOILS REPORT FOR WATERPROOFING & DRAINAGE SYSTEM. 12. 2X6 CONT. SHEAR KEY. 13. CONG. FOOTING, (F'c = 4500 PSI, TYPE V CEMENT). 14. #4@ 16" 0.C. T & B. 15. ADD#5 16. CONC. KEY PER SCHEDULE 17. Z-BARS PER SCHEDULE 18. SUBGRADE PREPARATION PER SOILS REPORT. NOTES: -WATERPROOFING, EXTENT OF BACKFILL, BACKFILL MATERIAL & DRAINAGE SYSTEM TO BE REVIEWED & APPROVED BY GEOTECHNICAL ENGINEER -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. -SPECIAL INSPECTION REQUIRED FOR CONCRETE. NOTTO SCALE 3 STEM (Fl) H 6'-0" MAX. -----··------------------ CABLE RAILING- INSTALLED BY OTHERS, SEE CAL TRANS STANDARD (NEW CONSTRUCTION) AS A GUIDELINE. 2" GLR <SI 1 :c G 1. \2) #4 CONTINUOUS 2. O" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE LAP INTO WALL BELOW AS SHOWN. 5. (2) #5 CONTINUOUS,,,"·" "·· 6. 16" CONCRETE RETAINING WALL, (F'c = 4500 PSI, TYPE V CEMENT). 7. X2-BARS PER SCHEDULE 8. Y2-BARS AT INSIDE FACE PER SCHEDULE, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 9. #5@ 16" O.C. VERT. AND #4 @ 16" O.C. HORIZ. U.N.O. 10. COMPACTED BACKFILL APPROVED BY SOILS ENGINEER 11. REFER TO SOILS REPORT FOR WATERPROOFING & DRAINAGE SYSTEM. 12. 2X6 CONT. S.HEAR KEY. 13. CONG. FOOTING, (F'c = 4500 PSI, TYPE V CEMENT). 14. #4 @ 16" 0.C. T & B. 15. ADD#5 " 16. CONG. KEY PER SCHEDULE 17. 18. Z-BARS PER SCHEDULE 19. SUBGRADE PREPARATION PER SOILS REPORT. 20. #5@16" O.C. AT OUTSIDE FACE, DOWEL INTO FOOTING AS SHOWN WI STD. HOOK i_,,,_ __ (D-~a-·-··--tttzi'•IL ~ I. ~~..,,..,.,.,.,...,-,,,i~ ............ ...-.,.,, 19 ®-- 2" GLR 12 ~---1oci1 I, ',/ ·--<,::-.. <:,: ,,, ~,' '><: // ~,,-" ::<: B" /, 1/,,, :.,,>, 1/,<, K / 15 1,4 +-----F ------+--E -·,f---D __ __,, +----------c----~-------,,- FOUNDATION (Ft) A B C D E F G XI 1'-2" 7'-2" 10'-0" 3'-0" 1'-0" 6'-0" 1'-0" #5@16"0.C. ·.:·:~'., " <( "' \\_SEE CIVIL DRAWING FOR MORE INFORMATION. NOTES: -WATERPROOFING, EXTENT OF BACKFILL, BACKFILL MATERIAL & DRAINAGE SYSTEM TO BE REVIEWED & APPROVED BY GEOTECHNICAL ENGINEER. -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. -SPECIAL INSPECTION REQUIRED FOR CONCRETE. REINFORCEMENT YI X2 Y2 z 1l6@8'0.C. #5@16"0.C. #7@8"0,C, #5@16"0.C. EACH FACE TOP &BOTT. I :c 3 ~--E---B" +-----C·-- SEE GRADING PLAN Ii'. .i-1--i-· MORTAR k CAP 1'-0" • ' , D -. a· ;:7< :ii ,:f;:J;;-, ~:>>A- 13 I I I I p -z;:~o <( --+ "' '):~ y;~ CONCRETE VDITC ~~ :c " I I------_,__ STEM (Ft) FOUNDATION (Ft) H 7'-0' MAX. H 8'-0" MAX. H1 H2 H3 A B C D 3'-8" 3'-4" 12' 12" 2'-4" 4'-6" 12· MAX. MIN. REINFORCEMENT X1 X2 Y1 Y2 Z #4@24" O.C. #4@16" O.C. #4@16"0.C. #5@8'0.C. TO~;;;;;:;:· E 3'-5' 1. (2) #4 CONTINUOUS 2. 8" SOLID GROUTED CMU. 3. X1-BARS PER SCHEDULE 4. Y1-BARS PER SCHEDULE 5. 12" SOLID GROUTED C.M.U. 6. X2-BARS PER SCHEDULE 7. Y2-BARS PER SCHEDULE DOWEL INTO FOOTING AS SHOWN WI STD. HOOK. 8. #5@ 18" O.C. VERT. AND #4 @ Hi" 0.C. H. ORIZ. U.N.0. 9. CONG. FOOTING, (F'c = 4500 PSI. TYPE V CEMENT). 10. #4@ 16" O.C. T & B. 11. ADD #5 12. CONG. KEY PER SCHEDULE 13. REFER TO SOILS REPORT FOR WATERPROOFING & DRAINAGE SYSTEM. 14. FOOTING @ ADJACENT STRUCTURE/BUILDING 15. Z-BARS PER SCHEDULE 16. COMPACTED BACKFILL APPROVED BY SOILS ENGINEER 'NOTES: -SPECIAL INSPECTION IS REQUIRED FOR ALL CMU WALL. -WATERPROOFING, EXTENT OF BACKFILL. BACKFILL MATERIAL & DRAINAGE SYSTEM TO BE REVIEWED & APPROVED BY GEOTECHNICAL ENGINEER. -EDGE DISTANCE TO REBAR INDICATED IS CLEAR DIMENSION. RETAINING WALL #7 2 RETAINING WALLS# 18,23,24,25,33 1 NOTTO SCALE AS-&JH..r DATE INITIAL i'JGil'JEER []f"" \./ORK REVISI □t, DESCRIPTION FNGil'-IEER OF 1,/DRK GD U VIS ENG l r-.J EE RI r-.:G HIJAfl NGUYEN R,[,[, S42J8 DATF DATE INITIAL DATE INJTIAL OTHER APPROVAL CITY APPROVAL EXP CITY □~ CARLSBAD I s13T I C:NGINEERING DEPARTMENT RETA!fl!NG 1iALL PU\NS f'OR• POINSETTIA CTHE PROPERTIES TIDES) DATC: DATE SI IEETS l3 V 05-01/PIJD 0500/CDP 05-23 APP"UVED_ ;,IL_ 1(2',,,, ~ GLEN K, '//\10~! SE,NIOR c1vri%1NEER 0 E 41204 C:XP!RES J/31/13 ~DATE D \m By\ ---.'Gae['n-_ CHKD DY (')2:(C: R\/\,/D BY: PROJECT 1-.Jr: CT 05-10 DRA \✓Ii'IG ~IC, 1\69 8(~