Loading...
HomeMy WebLinkAboutDWG 471-9A; CT 06-15; TABATA RANCH; 01-03GRADING NOTES ' (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15 16 OF THE CARLSBAD MUNICIPAL CODE) 1 THIS PLAN SUPERCEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS 2 APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED 29 THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND /RR/GA TION PLANS ANO THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS JO WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS ANO REPLACED WITH PROPERLY COMPACTED SOILS IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER J CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF-J1 WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED OUR/NG CONSTRUCTION ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVE GROUND AND UNDER GROUND ) WITHIN THE PROJECT SITE SUFFJCIENTL Y AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK 4 A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY 1 WORK IN THE PUBLIC RIGHT OF WAY PRIOR TO PERMIT ISSUANCE, A J2 ,CERTIFICATE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE 'FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERM/TT££'$ POLICY IN THE MINIMUM AMOUNT OF $1,000,000 00 FOR EACH OCCURRANCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HA VE A RA TING OF •A-• OR BETTER AND A SIZE CATEGORY OF CLASS V OR BETTER AS ESTABLISHED BY ·aEsTS· KEY RA TING GU/OE 5 NOT USED THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COOROJNA TE THE WORK WITH A COMPANY REPRESENTATIVE UNDERGROUND SERVICE ALERT (800)422-4133 SDG&E (800)660-7J4J PACIFIC BELL (800)892-0123 TIME WARNER CABLE (760)438-7741 COX COMMUN/CATIONS (766)806-9809 CITY OF CARLSBAO(STREETS & STORM DRAIN) (760)434-2980 'CITY OF CARLSBAD(SEWER,WATER & RECLA/MEO WATER) (760)438-2722 EROSION CONTROL NOTES 1 IN CASE EMERGENCY WORK IS REQUIRED, CONTACT ROBERT FUREY AT (619) 921-9452 2 EQUIPMENT ANO WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCT/ON OF TEMPORARY DEVICES WI-IEN RAIN IS EMINENT 3 DEVICES SHOWN ON PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR 4 5 6 THE CONTRACTOR SHALL RESTORE ALL ERO;,JON CONTROL DE\11CES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WI-I/CH MAY ARISE THE CONTRACTOR SHALL BE RESPONSIBLE ANO SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WI-IERE IMPOUNDED WATERS CREA TE A HAZARDOUS CONDITION 7 ALL EROSION CONTROL MEASURES PR0\11DED PER THE APPROVED GRADING PLAN SHALL BE INCORPORATED HEREON 8 GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY 9 ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WI-IEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT ( 40%) SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL 6 , NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM , THE CITY ANO OTHER APPROPRIATE AGENCIES 'SAN DIEGU/TO WATER DISTRICT (760)6JJ-2650 'LEUCADIA WASTEWATER DISTRICT (760)753-0155 10 ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH J/4 INCH MINIMUM AGGREGRA TE 7 , APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY 'WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION 1HAS BEEN OBTAINED ANO A VALID GRADING PERMIT HAS BEEN ISSUED 8 , NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL ! OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE ,APPROPRJA TE SHEET OF THE PLANS AND THE TITLE SHEET !I. ORIGINAL ORA WINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING ' SIGNED BY THE CITY ENGINEER 10 i THE ORIGINAL DRAWING SHALL BE REV/SEO TO REFLECT AS-BUILT CONDITIONS ,BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE ,CITY 11 'ACCESS FOR FIRE ANO OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCT/ON 12 WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF (A) SUMMARY SHEET, (8) LABORATORY WORK SHEETS ANO (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRING/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS !MECHANICS THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING 1 /NSPECTOR WITHIN TWO WORKING DA Y5 OF THE COMPLETION OF FIELD TESTS 1J :A SOILS COMPACTION REPORT ANO COMPLIANCE VERIFICATION REGARDING ; ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED IPR/OR TO THE ISSUANCE OF A BUILDING PERMIT ALL CONTROLLED GRADING 1 SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE 1STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FJELD OF APPLIED 1 SOILS MECHANICS ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ,ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS ANO THE ,. EARTHWORK SPECIF/CATIONS • A TTACHEO TO THE PRELIMINARY SOILS INVEST/GA TION DAILY FJELD COMPACTION REPORTS WILL BE SUBMITTED TO THE 'VALLECITOS WATER DISTRICT (760)744-0460 'OLIVENHAJN WATER DISTRICT (760)753-6466 'BUENA SANITATION DISTRICT (760)726-1340 *AS APPROPRJA TE J3 PERMIT COMPLIANCE REQUIREMENTS A FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, ANO/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE ANO CONTROL THE WORK IN PROGRESS {15 16120 A 8} CARLSBAD MUNICIPAL CODE B PRIOR TO FINAL APPROVAL OF A GRADING PERMIT -THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER \11A THE PROJECT INSPECTOR {15 16 120 A 10} CARLSBAD MUNICIPAL CODE (1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STA TING ALL GRADING IS COMPLETE ALL EROSION CONTROL, SLOPE PLANTING AND /RR/GA T/ON ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS ( OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT) (2) AS-BUILT GRADING PLAN (J) REPORT FROM THE SOILS ENGINEER, WI-I/CH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, ANO SUMMARIES OF FIELD ANO LABORATORY TESTS THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS ANO RECOMMENOA TIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO ( 4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE 11 PROJECT INSPECTOR 'I CITY 14 A PRECQNSTRIICDON MfEDNG SHAil BF HF/ D AT THE SITE PRIOR TO THF 34 BEGINNING OF WORK AND SHA/ I BF A TTFNDED BY Ali REPRE5£NTA DYES UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK PLANCHECK FEES WILL 8£ REQUIRED FOR ANY SUCH RECHECK RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING ANO ALL OTHER ASPECTS OF THF WORK. THE CONTRACTOR SHALL REQUEST A PRECONSTRUCT/ON MEETING BY CALLING THE INSPECTION LINE AT (760) 4J8-J8!11 AT LEAST FIVE(5) :WORKING DA Y5 PRIOR TO STARTING CONSTRUCTION THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DA TE ANO TIME FOR THE PRECONSTRUCTION MEETING APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING 15 . All INSPFCTION RFOIIESTS OTHER THAN FOR PRFCONSTRI/CTION MfFT/NG W0i BF IMAGE BY CAllfNG THE FNGJNFFRING 24-HQIIR IN$PFCTION RFQIIFST /INF AT (760) 438 3891, INSPtCDON RFQUEST MUST BF RECEIVED PRIOR TO 2, oo P.M, , ON THE DAY BEFORE THE INSPECTION IS NEEDED INSPECTIONS WILL BE MAO£ THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE REQUESTS MADE AFTER 2 00 P M WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER 35 ~~p~~'il ;fPORT TITLWNJE f~g~~D~R~:1~~GTABATA RANCH 'OATEo' AUGUST 2 ,20Jl!L, SHALL BE CONSIDERED AS A PART OF THIS GRADING PLAN ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIF/CATIONS CONTAINED IN SAID SOILS REPORT •DECLARATION OF RESPONSIBLE CHARGE• I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS SHOULD GERM/NATION OF HYDROSEEDED $~OPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35 023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, STA TE OF CALIFORNIA TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND /RR/GA TION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIF/CATIONS ANO THE FOLLOWING A HYOROSEEDING SHALL BE APPLIED TO 1 ALL SLOPES THAT ARE GRADED 6 1 (HORIZONTAL TO VERTICAL) OR STEEPER WI-IEN THEY ARE 2 a THREE FEET OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET b ALL SLOPES 4 FEET OR MORE IN HEIGHT AREAS GRADED FLATTER THAN 6 1 WHEN ANY OF THE FOLLOWING CONDITIONS EXIST a NOT SCHEDULED FOR IMPROVE/rfENTS(CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DA Y-'1 OF ROUGH GRADING b IDENTIFIED BY THE PARKS ANO RECREATION DIRECTOR AS HIGHLY VISIBLE TO THE PUBLIC c HA VE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREATMENT 8 HYDROSEEDEO AREAS SHALL BE /RR/GA TEO IN ACCORDANCE WITH THE FOLLOWING CRITERIA 1 ALL SLOPES THAT ARE GRADED 6 1 OR STEEPER AND THAT ARE 2 3 a THREE TO EIGHT FEET IN HEIGHT SHALL BE /RR/GA TEO BY HANO WATERING FROM QUICK COUPLfiRS/HOSE BIBS OR A CONVENTIONAL SYSTEM OF LOW PREC/PITA TION SPRINKLER HEADS PROVIDING 100% COVERAGE b GREATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE AREAS SLOPED LESS THAN 6 1 SHALL BE /RR/GA TEO AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYOROSEEOING THE DEVELOPER SHALL SUBMIT A PROPOSED SCHEME TO PROVIDE /RR/GA TION TO THE CITY ENGINEER THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPES AND COSTS OF THE ELEMENTS OF THE THE PROPOSED SYSTEM /RR/GA TION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM LEVEL FOR THE GROWTH OF THE H)'OROSEEOED GROWTH 16 THE OWNER ANO/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT ANO MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STA TE ANO FEDERAL SAFETY ANO HEAL TH STANDARDS, LAWS AND REGULA T/ONS I UNDERSTAND THAT THE CHECK OF PROJECT ORA WINGS AND SPECIF/CATIONS BY THE c CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY HYDROSEEDING MIX SHALL CONSIST OF ALL OF THE FOLLOWING 1 SEED MIX SHALL CONSIST OF NO LESS THAN 17 THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMlmNG A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING , THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE I OF WORKER PROTECTION FROM THE HAZARD OF CA YING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR OUR/NG THE PIPE INSTALLATION THEREIN THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION IF THF PL AN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS. TITLE 8 CALIFORNIA ADMINISTRADYE CODE. THE PLAN SHALL BF PREPARED BY A REG/STFRFD ENGINEER AT THF CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION 18 • NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD SUBMIT APPL/CATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERA T/ONS 19 i IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA : DURING CONSTRUCTION, OPFRA noNS WILL CEASE /MMEDIA TEL Y, AND THE PERM/TT££ WILL NOTIFY THE CITY ENGINEER OPERATIONS WILL NOT RESTART , UNTIL THE PERM/TT££ HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO 00 SO 20: ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING , WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCT/ON EQUIPMENT AND ANY OTHER ASSOC/A TED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7 00 AM ANO 6 00 PM EACH DAY, MONDAY THRU FRIDAY ANO NO EARTHMOVING OR GRADING OPERATIONS SHALL 8£ CONDUCTED ON WEEKENDS OR HOL/DA YS (A LIST OF CITY HOLIOA YS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER) 21, ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DA Y5 PRIOR TO BEGINNING OF WORK 22: IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER THF CONTRACTOR SHAL t BF RFSPONSIBL E FOR ANY DEBRIS OR DAMAGE OCCURRING Al ONG THE HAUi RESPONSIBILITIES FOR PROJECT DESIGN FIRM REC CONSULT AN1S, INC ADDRESS 2442 SECOND A'l£NUE CITY, STATE SAN Dl~EGO CA • TELEPH0~19 232.920<L 1 BY f ) 2 \.....7 BRUCE ROBERTSON RC E NO ___ _;4:,,8529.,.,,,.___ _____ _ NO 48529 XP 6/30/1 REGISTRA T/ON EXP/RATION DA TE ---"6/'--'30CC'-..Vc..14;_____ 1 /I?// DATE -~-'-'l"'(c,-__ SOIIS ENGINEER'S CERTIFICATE /, S MEHDI SHARIAT , A REGISTERED (CIVIL/ GEOTECHNICAL) ENGINEER OF THE STATE OF CALIFORNIA, PR/NC/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT A SAMPLING ANO STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DA TES OF AUGUST 1 , 20 06 AND AUGUST 2 , 20.QJL TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE yr.--THF' CITY ENGINEER ~ / ' <,~ ,> ~ <' SIGNED ~'~1"•<'~.J:!::'=a~c.,,~;;;;:::__s~=::::::_ __ _ !'<: ~ -GE/PE NO 2855 No "886 l> ~c..:..::;__ _________ _ k Exp 1213111< -, DA TE _..,,2~/:..,k?"-4-/ f,.,4:?------------- '{t~,,@j;\\r))'-"~"' LICENSE EXP/RATION DA TE 12./3 r l"4 -.01-cAW ··-·=-OWNER'S CERTIFICATE ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERA T/ON I ( WE ) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR 2J, BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED NO TREES ARE GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL TO BE REMOVED UNLESS SPECIF/CALLY NOTED ON THE PLAN GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF 24' ALL AREAS SHALL BE GRADED TO DRAIN GRADING RESULTING IN THE PONO/NG OF THIS SITE ~ iJJi : WATER IS NOT PERMITTED ALL EARTHEN SWALES AND DITCHES SHALL HAVE A /M l.--?-/(,·/'-' MINIMUM ONE PERCENT SLOPE ( 1 25: THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SET OF EROSION --• .JE~P:1'._]TABA DATE 1 CONTROL PLANS EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR SOURCE OF TOPOGRAPHY 2 3 a 20 lbs PER ACRE OF ROSE CLbVER b 20 lbs PER ACRE OF ZORRO FESCUE c J lbs PER ACRE OF E SCHOOL CIA CALIFORNICA d , 4 lbs PER ACRE OF ACHILLEA 1M/LLEFOLIA e , 3 lbs PER ACRE OF AL YSSUM '(CARPET OF SNOW) f 1/2 lb PER ACRE OF DIMORPHOLECA g ITEMS c,d,e, AND f OF THIS SUBSECTION MAY BE OMITTED ON LOCATIONS WI-IERE THE AREA BEING HYDROSEEDED IS NOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES h ITEM a OF THIS SUBSECTION MUST BE INOCULA TEO WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCASTING BEFORE H YDf?OSEEOING ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD ANO AGR/CUL TUR£ CERT/FICA TION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS J NON-PHYTO-TOX/C WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR TYPE 1 MULCH APPLIED AT THE RA TE OF NO LESS THAN 2000 lbs PER ACRE TYPE 6 MULCH (STRAW) MAY BE SUBSTITUTED, ALL OR PART, FOR HYDRAULICALLY APPLIED FIBER MATERIAL WI-IEN STRAW IS USED IT MUST BE ANCHORED TO THE SLOPE BY ME;CHANICALL Y PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOIL FERTILIZER CONSISTING OF AMMON/f/M PHOSPHATE SULFATE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RA TE OF 500 lbs PER ACRE D AREAS TO BE HYDROSEEOEO SHALL BE PREPARED PRIOR TO HYDROSEEOING BY 1 ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A COMB/NATION OF 2 a TRACK WALKING SLOPES STEEPER THAN 6 1 b HARROWING AREAS 6 1 OR FLATTER THAT ARE SUFFICIENTLY FRIABLE c RIPPING AREAS THAT WILL NQT BREAK UP USING ITEMS a OR b ABOVE CONDITION/NG THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY a ADJUSTING THE SURFACE SQIL MOISTURE TO PROVIDE A DAMP BUT NOT SATURATED SEED BED b THE ADDITION OF SOIL AMENOMtNTS, PH ADJUSTMENT, LEACHING COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR GROWTH £ HYDROSEEOED AREAS SHALL BE MAINTAINEO TO PROVIDE A VIGOROUS GROWTH UNTIL THE THE PROJECT IS PERMANENTLY LANDSCAPED, OR, FOR AREAS WI-IERE HYDROSEEDING IS THE THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED 261 ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY AERIAL SURFACE ANO CROSS SECTION THE SITE SHALL BE LEFT IN A NEAT AND TOPOGRAPHY METHODS FROM INFORMATION GATHERED ON JANUARY , ORDERLY CONDITION ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED 25, 2007, BY SAN-LO AERIALS TOPOGRAPHY SHOWN HEREON BASIS OF BEARINGS GRADING PLANS FOR T ABAT A RANCH cIJ_y\ VICINITY MAP NTS LEGAL DESCRIPTION LOT J5 OF MAP NO 14773 TOGETHER WITH A PORTION OF THE NE 1/4 SEC 28 T125 R4W INDEX OF SHEETS SHEET 1 -TITLE SHEET SHEET 2 -SECTIONS ANO DETAILS SHEET J -ROUGH GRADING PLAN BENCH MARK DESCRIPTION _.Fe_.O:...,..eWieaEL.,L~MecOeeN.,_,Ue,Mc,aENccT'--'"M-"'AR"-'K1=Ea<D..!L""S"--'5"'6~69,...._ _____ _ LOCATION ---"'INC!'TE.,.R,,,S,cEC""T/"'O"'N'-"'OF--"'B""LA,,Cc,;,K_,R.,,:A,,.,IL'-'-"RD"--'A:,cN,,,D:..,M,eA:,,.R'-'Tl"-'N"'GA-"'L=Ec.:C"'T'---- RECORDEO_-'P-'T--""N""0-'-'46......,_,(C.,,L"'SB"---....,0'-'4-"6'-) .,_PE,aR.,__,_,_R,cOS"--'-1'-'72.c7.,_1 _____ _ ELEVATION J42 747 DA TUM NGVD 29 =~~------- TYPE .& WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARA T/ON OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHO'NN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIF/CATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER 1 CARLSBAD MUNICIPAL CODE 2 CITY OF CARLSBAD ENGINEERING STANDARDS J THIS SET OF PLANS 4 RESOLUTION NO 6619 DA TED 8-5-2009 5 THE STANDARD SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6 SOILS REPORT AND RECOMMENDATIONS BY VINJE AND MIDDLETON ENGINEERING DATED 8-2-2006 7 THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS 8 CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED N,/A 9 ENVIRONMENTAL APPROVAL DOCUMENTS DA TED 8-5-2009 10 STORM WATER POLLUTION PREVENTION PLAN PREPARED BY RFC CONSlll TANIS /NC DATEO_Jc...--=2cc0-'-'11 ___ _ WOID NO 9 J7CJ67951 11 STORM WATER MANAGEMENT PLAN PREPARED BY REC CONSULTANTS, INC DATED 7-20/J, Sl+MP I 11-06 12 CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK ANO CAL TRANS CONSTRUCT/ON SITE BMP MANUAL DESCRIPTION SUBDIVISION BOUNDARY PROPOSED EVEVA T/ON PROPOSED CONTOURS BROW DITCH TYPE "B• FLOW DIRECTION PROPOSED SLOPE EXIST SLOPE SWALE FLOWLINE RETAINING WALLS 8" YARD DRAIN EXISTING: EXIST CONTOURS EXIST ELEVATIONS LEGEND DlrG.NO. SYMBOL ---- ~ ~ 0-15 => y -r- __ L_ - C-3, C-4 □ _.,.-5:JO _/ --~ EXIST OVERHEAD ELECTRIC LINE EXIST STORM DRAIN --E [G ===SO=== SEWER MAIN ---s--- SEWER MANHOLE WATER MAIN ---w-- GAS LINE ---G--- TELEPHONE LINE ---T--- REQUIRED TREATMENT CONTROL Bl(p TABLI! • OllNERSHIP IWNTllNANCE SllDT NO, QTY. !GRl!IOO!NT YES & CC&:RS 3 1 QUANTITY 612 LF 2,200 SF 1 EA IWNTINANCE PRIQUBNCY AS NEEDED REFERENCE DRAWINGS MAP 14773 YES & CC&RS 1 BloRFTfJJT/t/1 BA5lt/ 1 -ST/1,~'NJ!flfl'.,'~ Pl./tC-€ JIQll;IJI ~11:G tr ~l".1£ PVT BIORETENTION ;l,>,5111 3 -!'17f',J,1',51i~f('~ l'l.l{l: SC(J!K ~l!lG Cf i:NLJ~!B.;;t---::P"'VT::--+--------+---'---+-"'---+- 3 AS NEEDED MAP 13394 CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO CARLSBAD DWG NO 401-9J 401-9D 401-9C 341-3 267-9 258-2 256-8 230-6 ,...,-, I I UU 'L ' ' - . . . ..... ' - YES &: CC&:RS -,-~&eec&Rs ~ . ·--"------. ·--- CC&RS & BMP MH,ej I """M ·--,. -fle-TERRA-GATGH-BASIN-Fle-TE-1+-R --sTRAl'IBERR-¥-PtAG&-NQR.tH-OO)le-'.:-1---G --·r ->¥-'--1--'l'l~!c-C:c&t~ -flLKRRA ": .... :: : _ ,_.. ~:~ ::::-... ,. . -..-,.. ,... ... \1-1 ._,,,.,._ ,..,. TTrl ·-·--,. ·- 3 " - - " , -. . . SUSMP PROJECT PRIORITY WGH CONSTRUCTI9 PRIORITY HIGH 1 AS NEEDED 1= '=-"""NE€0E!J=- • ~ • ... . ' -ll--' ' -. • PER MANUFACTRS RECOM!.IENDATIOFf' ' PER MANUF ACTRS , ... 11,u,, •FOR MORE INFORMATION REFER TO THE TABATA RANCH STORM WATER MANAGEMENT PLAN, JULY 2013 / ? .---f--f-----H------------, / 1;/ ''.Ns BUILT" EARTHWORK QUANTITIES (1{{iflufl1/' i _, G-iq F~L _ __:2:c,4c:O.::.O __ cy CUT 19600 CY R;FJtf1't-6 EXP {t~~(-(1 NOTE: DATE IMPORT O CY EXPORT ll,200 CY DEVELOPER SHALL COMPLY WITH SAN DIEGO REGIONAL WATER REVIE;W<'n' E J ~ QUALITY CONTROL BOARD RESOLUTION R9-2013-0001 REGARDING r·r ' fl / J )# OFF-SITE DISPOSAL OF SOIL .,.v ,r fAv fl IA t7/ :i/~ I~ RE¥E9IAL O CY Aiffi~~~~~::==r=~=r=r==r==r=r=~=r=;:;;:;;,;~'~N;SP;E;C~T;O~R::;:::;;;::::::;;:::;::;;:::;;::;;;:;;;:::;::;;:~D~fi.~:l'E~:;;;:~ '1/1111~ 'f74'J. rf1 "116'-{\-,£'t;, 4 J~j),tl::N'I /1,'al:(17.t:1.,J;-"'l,-+_lf--+--i--+-+--I--I---I -r ,.,., ~ ~t~ .. , x~, i--.<!..-rt6"~ . ISHfE'il CITY OF CARISBAD I sHE3Ers I f---+---+o!<'-'""_. ~. =., -'T f" ·' ./~',--,J-,•.-\+-+--1--1-+--f--1---e--l LJ_j ENGINEERING DEPARTMENT "' "1 t:;,ct;, 'Th \;.1 .U VI-t01·;E,-twJ-·1tw ~G;;RAD;:;:;:IN~G~P:;:LAN;:;;:;S~FO~R;;'=::::::::::::::::::::::::::::::::::::::==:..::=:::::~ ~ ~.;1. · '7l01l10. 'JZAI, ' -0 '1~1llB° TABATA RANCH TITLE AND INDEX SHEET AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER CONFORMS TO NATIONAL MAP ACCURACY STANDARDS 27' ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED THE BASIS OF BEARING FOR THIS SURVEY IS THE CCS 83, ZONE 6, (EPOCH 1991 35) GRID BEARING BETWEEN STATION CLSB-050 AND CLSB-047 (BOTH HAYING A CALIFORNIA COORDINATE VALUE OF FIRST ORDER ACCURACY), PER ROS 17271 I E N 76"38' 42" E Civil Engineering Environmental APPRO~. /J li~4 GLEN K. VAN P;t' 'WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE PROJECT LOCATION , AS SHOWN ON THE APPROVED GRADING PLANS _ 28 ', LANDSCAPING SHAL,L BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED THIS PROJECT /S LOCATED WITHIN ASSESSORS PARCEL NUMBER($) i BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR 214-631-20, 21, &: 214-630-20 , THIS PROJECT, DRAWING NO 471-9L , AND/OR AS DIRECTED BY THE CITY THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS 'ENGINEER OR PLANNING DIRECTOR N 344 £ 16 -""'--'---------- SAV1f DATE 1/7/2014 12 04 PM -FILE PATH P \ACAD\856 TABATA RANCH\GRADING\GRD-01 DWG Consultants, Inc Land Surveying 2442 Second Avenue Son Otego, CA 92101 (619)232-9200 (619)232-9210 Fox <f/11/r!S 1!,.llP, f1\lf6P/.llC6 S/JF.6T.S .7. .:j3, ~/QNiiD 3-Jt.-l"/ 1•Z~IS 7fM 1/ // JS: 1 =t, DATE INITIAL DATE INITIAL I A INITIAL ENGINEER Of WORK REVISION DESCRIPTION OlHER APPROVAL CITY APPROVAL , t:i ~-~ ,(o(. 3 z..}l!L CllY EN !NEER PE 41204 EXPIRES 3/31115 DA TE OWN BY. CHKD sy,-3~a=1~ RYWD BY. PROJECT NO, CT 06-15 DRAWING NO. 471-9A \ 010716 RffiHTION AREA SHALL BE LEVEL AND DEPRESSED A MINIMUM OF 8" FROM THE SURROUNDING GRADE 18" MIN S££ NOTE *' BELOW / DEEP ROOTED, DENSE, DROUGHT TOLERANT PLANTING SUITABLE FOR WELL DRAINED SOIL APPROVED GRATE INLET IN BIORETENTION SWALE 8 / CONSTRUCT 12" AGGREGATE CHECK DAMS EVERY 20 FEET ALONG 5% GRADED BASIN FINISHED GRADE AS SHOWN ON PLANS 2-3" HARDWOOD MULCH C'- 5\lf[~'II i8 mmmmmmm1 111!~1 Ii' I 1m1 I 11 Ii' 11 1Ii'I 1m111 1 I I 11 = =11 111-111 Ill Ill Ill 1------- ~~~-ta• MIN ENGINEERED SOIL ~ SEE NOTE • BELOW ,,_... 2-3• OF 3/8• GRAVEL ;i@~?f---.-3/4" CRUSHED ROCK ~~" ~ ' ' nE 4• PERFORATED PVC PIPE INTO RISER 4" PVC PIPE TO 4 • PERFORATED PVC PIPE STORM DRAIN SYSTEM WITH PERFORATIONS AT THE INVERT ' BIORffiHTION ENGINEERED SOIL LAYER SHALL BE MINIMUM 18" DEEP •SANDY LOAM• SOIL MIX WITH NO MORE THAN 5::1 CLAY CONTENT THE MIX SHALL CONTAIN 50-60::1 SAND, 20-30% COMPOST OR HARDWOOD MULCH, AND 20-30% TOPSOIL *'3/4• CRUSHED ROCK LAYER SHALL BE A MINIMUM OF tB• THE EFFECTIVE AREA OF THE BASIN SHALL BE LEVEL LOCATIONS BIORmNnON SWALE A, 8/0RETEHTION SWALE 8 FOR LOTS 1, 2, J, 4 & 5, REFER TO BMP TABLE SHEET J ' VRLOT 0 6 ,_____1o·_i(H0A MAINTAINED) SOLID LINE REPRESENTS PROPOSED FINISHED GRADE DASHED LINE REPRESENTS EXISTING CONDJTJONS I INSTALL HANDRAILS TW 255 75 PROP ED CMU REJ ING WALL E C-4 W/ DESERT TAN SPLIT FACE FINISH ~ TW 251 4 SUBDIVISION BOUNDARY LOT 34 MAP 14773 €l-(r-1 tNA-rf- l', " MODIFIED U TYPE HfADWAL,/r c:..,..rt Of-t 17 PER D-34 "7l;;. "I ' ~-;{!AV/ ///Y/ PROPOSED RIP RAP ENERGY DISS/PA TOR BIORETENT70N DETAILED SECTION STRAWBERRY PLACE JUNCTION BOX/ TRANSFORMtR PUE BY OTHERS WHERE REQUIRED LINED BROW DJTC NTS PROPOSED NTS PROPOSED LIMIT OF SLOPE & LANDSCAPE EASEMENT EXISnNG BROW DITCH TO REMAIN [----PROPOSED LOT 2 I LOT LINE : PAD=300.0 i----PROPOSED I LOT LINE PROPOSED 0-75 BROW DITCH WI EARTH TONED 1YPE CONCRETE l ct SUBDIVISION~ BOUNDARY 12" WATER MAIN PROTECT IN PLACE 30' ESMT PER DWG 341-J -]35' STREET LIGHT AT END OF CUL -DE -SAC f Row SUBDIVISION BOUNDARY 1' 28' ROW I ROW VARIES 16" WATER MAIN PROTECT IN PLACE 56' 28' 28' JUNCTION BOX/ TRANSFORMER 10' 18' PUE BY OTHERS WHERE REQUIRED 3' ,~ PROPOSED G-2 I PROPOSED G-2 CURB & GUTTER CURB & GUTTER I 'l- JOINT UTILITY TRENCH DESERT TAN DECORAnVE PROPOSED D-75 DESERT TAN CHAMFERED EDGE CAP BROW DITCH OR CITY WITH 1 • REVEAL OR APPROVED EQUIVALENT CITY APPROVED EQUIVALENT i' f TYPICAL SECTION RIGHi-i'f_<!ffff-----.._ S O ' DESERT TAN DECORAnVE ¾'0-V( CHAMFERED EDGE CAP 3 5• ~ PROPOSED TYPE C-4 CMU RETAINING PROPOSED PUBLIC CUL-DE-SAC STREET STA. 1+20.38 -STA. 3+34.44 WITH 1 • REVEAL OR ,-=+~S;;:~ WALL WI DESERT TAN CITY APPROVED EQUIVALENT J 5 SPLIT FACE FINISH 5' 5' RW 10' (J 5' MAX EXPOSED) NTS Civil Engineering Environmental Land Surveying 2442 Second Avenue PROP CONG ~1-::::::::;✓-"v---~r=fl!:::r-LH.~~i";a='.J TOP OF FOOnNG ~E~~ go~~TTER~ SIDEWALK \ f6 -;::~ ,!:, . o5•f '-'. '";-, ~~da:.:;::::::~-PROPOSED TYPE C-4 CMU RETAINING 2::1 2% WALL WI DESERT TAN L( < / / -----...... J , -;-.-~~~1,-.,.~, .. ~ SPUT F'AC£ ANISH :S:, ... " r '! ~/•~~'RS ~~, {J 5' MAX eXPOSED) SEC SECT/ONG NTS 1' LAP - I -- • ., 1'-10 112· n n n n n 5' ' ./ 5' PROP CONG SIDEWALK -111 - J 2" CLR -~ < n n 1-- 8. ,-1111 #4@ 12· 00>--;1--1-1_ 1_1 (BOTH WAYS) --- ~I_I_I_I LLLLI WING WALL REINFORCING •FOR ADDITIONAL DETAILS SEE SDRSD D-J4 :1/i ( /1 l DATE oi:.1- INITIAL San Diego, CA 92101 (619)232-9200 (619)232-9210 U TYPE HEADWALL ENGINEER OF WORK Consultants, Inc Fax NTS NTS SAVE DATE 1/7/2014 10 22 AM -FILE PATH. P \ACAD\856 TABATA RANCH\GRADING\GRD-02 DWG 21'± ~ PROPOSED) LOT LINE LOT 5 PAD=275.0 LOT 1 PAD 302.0 SUBDIVISION~ BOUNDARY I I PORTION j PROPOSED__.,.,., OF LOT I LOT LINE 1 2 1 •1·1,-';C., .. • , ~, LEMON LEAF DRIVE RETAINING WALL DETAIL -SECTION E STRAWBERRY PLACE (FACING NORTH) SUBDIVISION-I BOUNDARY EXIST BROW DITCH NTS i3 STRAWBERRY PLACE ,;; ,;;,'" ,;;~z;;,;;;;,,;;v' CLASS II AB (MINIMUM) Y/<~J# s:;~(f;~'fff ~'0J~®v ~'<~» --~~i'-<~'<1-" /~~{{f~~<(/(//Y 0-%< /~0(0:_"«("«(~' '.A~ ,1//,1//, / 1/1 / / ~~\y,,~/' a· PVC SEWER MAIN '~>::<~~'>'' / ROPOSED 6' WIDE ,,'<1/ I ~%,-::-: BMP TREATMENT SWALE 8" PVC WATER MAIN 11' JOINT UTILITY TRENCH ij,' (UNLESS OTHERWISE NOTED) fd, "1 BU LT" CROSS-SECTION F (FACING EAST) .. 'J'dPt,-z~tt~l1 5• <!'CC OVER 6" CLASS -;;E7q1z,, EXP ( t,. ~ 7-f~ DATE II AB FOR GRADIENTS GREATER THAN 10% /7 ~ A NOTE hD1i~u, 2,/ u,. ft_, FINAL STRUCTURAL SECTION PER (/LJ V O'I J 2--1 GEOTECHNICAL RECOMMENDATIONS INSPECTOR 1 DA7E I SH2ET I CITY OF CARLSBAD I SHE3TS I ENGINEERING DEPARTMENT GRADING PLANS FOR. TABATA RANCH DETAILS AND SECTIONS APPRO~ J • .L GLEN K. VAN P~~ b"" •. ~ , ,..l,fJ • ..... 3 J 'l. /1' d.J 111\ I u A-<r .... J(. " I • ·7;;·---;i 7 t;"t. ii D ;t 11 •J.i,i,1, 5/M !IJ!i_/1( r-;st; a1Y ~NEER PE 41204 EXPIRES 3 /31 /15 DA 1E DWN BY: I PROJECT NO. I DRA'MNG NO. DATE INITIAL DATE INITIAL CHKD BY: 5fJ CT 06-15 471-9A REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY. 0331111 fj ]0716 DEVELOPED BMPS AMENDED GRAVEL LOWER ORIF TOTAL SURFACE RISER POST-DEV. SURFACE V1 V2 BMP SOIL (IN) DIAMETER DEPTH HEIGKT IMPERVIOUS AREA (CF) (CF) (IN) (IN) (IN) (IN) % (SF) 1 18 24 1 25 18 6 56 6 750 375 600 2 18 24 1.25 18 9 202 778 584 622 3 18 24 1 125 18 9 34.3 965 724 772 . . " . 9/11/15 B A.R /1\ REPLACES SHEET ORIGINALLY SIGNED J/12/15 OKfE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL R.\Acad\856 Tabata Ronch\Grading\Grd-03REV dwg 5/21/2014 11 09 21 AM PDT 7071 I 8121 I 8123 I 8122 BMP CONSTRUCTION NOTES· [TI INSTALL 4" PERF PVC UNDERDRAIN PIPE @J INSTALL 4" CLEANOUT PER SC-01 WITH SCREW CAP 6" ABOVE GRADE (TYP) @] INSTALL FLOW CONTROL ORIFICE PLATE, SIZE PER PLAN REQUIRED TREATMENT CONTROL BMP. TABLE . ' DESCRIPTION Q1Y BIORETENTION BASIN 1 -STRAWBERRY PLACE SOUTH SIDE BIORETENTION BASIN 2 -STRAWBERRY PLACE NORTH OF KNUCKLE BIORETENTION BASIN 3 -STRAWBERRY PLACE NORTH OF KNUCKLE SUBDIVISION BOUNDARY LOT 34 MAP 14773 PROPOSED CMU RETAINING WALL TIPE C-1 W/ DESERT TAN SPLIT FACE FINISH PROPOSED RIP RAP £NE:RGY 0/SSIPATOR CROSS-SECTION D (FAQ/NG EAST) NTS 1 1 1 Civil Engineering Environmental Consultants;)T1c Land Surveying 2442 Second Avenue Son Diego, CA 92101 (619 32-9200 (619)232-9210 Fox EzUILT" z_ --( t .,(q EXP/1,. ,f (,/f DATE \ ' 010716 w i ~ 0 ! ..... w t