Loading...
HomeMy WebLinkAboutDWG 472-1; 5522; OCCIDENTAL INTERCEPTOR SEWER REHABILITATION; 01-05I I ! ' v-r}fl_~ ----,...----i ~~ -lr'°"""-'RD i0 PROJECT LOCATION SHEET NO. 1 2 J 4 5 DI INDEX OF SHEETS DESCRIPTION TITLE SHEET, VICINITY MAP, LOCATION MAP NOTES PLAN &: PROFILE-STA. o+oo TO STA. 12+85 PLAN &: PROFILE-STA. 12+85 TO STA. 25+20 DETAILS DIAL TOLL FREE 1 -800 -227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA HYDROGEN SULFIDE WARNING! VICINITY MAP NOT TO SCALE 4 CM.AVER-\ EXTREME HEALTH HAZARD. LEVELS UP TO 1,000 PPM OF HYDROGEN SULFIDE GAS (H2S) HAVE BEEN MEASURED IN THIS SEWER. COMPLY WITH OSHNCALOSHA REGULATIONS AND RECOMMENDATIONS AT ALL TIMES. CONSTRUCT/ON PLANS FOR OCCIDENTAL INTERCEPTOR SEWER REHABILITATION RD PROJECT NO. 5522 CITY OF CARLSBAD CARLSBAD, CALIFORNIA OCTOBER 2011 CITY COUNCIL MA TT HALL -MAYOR ANN KULCHIN -COUNCIL MEMBER MARK PACKARD -COUNCIL MEMBER KEITH BLACKBURN -COUNCIL MEMBER FARRAH DOUGLAS -COUNCIL MEMBER LISA HILDABRAND CITY MANAGER GLENNPRUIM UTILITIES DIRECTOR afESSlo,v,1( ENCINITAS SANITARY DIVISION APPROVED BY: ENC/NA WASTEWATER POLLUTION CONTROL FACILITY PROJECT LOCATION PALOMAR LOCATION MAP NOT TO SCALE "AS BUILT" 4/4,//~ I ' DATE REVIE\./ED BY, INSPECTOR DATE I SH1EET I CITY OF CARLSBAD I SHESETS I t-------+---+------------~-+----+--+-->---1 UTILITIES DEPARTMENT t------t---+--------------+----+--+--f-----'-1 IMPROVEMENT PLANS FOR: i:;-TERRY L. SMITH t------t---+--------------+----+--+--f-----'-1 OCCIDENTAL INTERCEPTOR SEWER REHABILITATION --"-!-(fl-"'. =1.-•+<'t+1<(f.,=,.u.~c½"""I""".., "'--) __ ID· 1p · I/ t---t----t------------1---t---t----+---1 TITLE SHEE°L VICINITY MAP C1TY'iNc111tdr DATE AND LOv'ATION MAP "' "' No. 42979 , . 03 31 LEUCADIA WASTEWATER DISTRICT APPROVED BY: ~&l.uA~'!;fr /0/11 /;1 uw' DISTRICT ENGINEER1-c£0f!t IZ • DA TE APPROVED WILLIA~ 1)-UMMER t--------t---+--------------+----+--+-----------,>---1 d-12.«4 Tl~· , = / 4ll2_,ll/ t-------+---+nc~------------+----+--+-----,f---1 DEPUTY CITY ENGINEER PE28176 EXPIRES J JI /2DATE 1M-~T DWN BY: PROJECT NO. I DRAWING NO. DATE INITIAL DATE INITIAL CHKD 8 MB ,_D_TH-ER-~~P-RO-VA-L-+-C-IT-Y -AP~PR-OV_A_,L, RVWD 8} TS 5522 472-1 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION I 121311 l.n 0 :::J" ~ m G) ,-+ I-' .i:,. 0 -..J ....., N \.n ' I-' GENERAL NOTES 1. A RIGHT-OF-WAY PERMIT W1LL BE REQUIRED FOR WORK IN THE PUBLJC RIGHT OF WAY. 2. NO WORK SHALL BE COMMENCE UNnL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY ANO OTHER APPROPRIATE AGENCIES AND A NOTICE TO PROCEED ISSUED BY THE CITY. 3. NO REVISIONS W1LL BE MADE TO THESE PLANS W1THOUT THE WRITTEN APPROVAL OF THE ENGINEER, NOTED 111THIN THE REVIS/ON BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND Ti TL£ SHEET. 4. THE ORIGINAL DRA 111NG SHALL 8£ REVISED TO REFLECT AS-BUILT CONDITIONS BY CONTRACTOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 5. THE CONTRACTOR SHALL OBTAIN AN [XCAVA noN PERMIT FROM THE DIVISION OF INDUSTRIAL SAFETY BEFORE ANY EXCAVA T/ON ANO SHALL ADHERE TO ALL PROVISIONS OF THE STA TE CONSTRUCT/ON SAFETY ORDERS. 6. CONTRACTOR SHALL DESIGN, CONSTRUCT ANO MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, ANO SHALL BE SOLELY RESPONSIBLE FOR CONFORM/NG TO ALL LOCAL, STA TE ANO FEDERAL SAFETY ANO HEAL TH STANDARDS, LAWS ANO REGULA T/ONS. 7. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE ENG/NEER THE DESIGN OF SHORING, BRACING SLOP£ OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECT/ON FROM THE HAZARD OF CAVING GROUND OUR/NG THE EXCA VAT/ON OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE JNSTALLAnON THEREIN. THIS PLAN MUST B£ PREPARED FOR ALL TRENCHES FIVE ffET (5') OR MORE IN DEPTH ANO APPROVED BY THE CITY ENG/NEER ANO/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCnON SAFETY ORDERS, TITLE 8 CALIFORNIA AOM/N/STRA T/V[ COO£, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVAnON PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCA VAT/ON. 8. THE EXISTENCE AND LOCA noN OF unLITY STRUCTURES ANO FACJL/nES SHOWN ON THE CONSTRUCT/ON PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENnON JS CALLED TO THE POSSIBLE EXISTENCE OF OTHER unLJTY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCA noN DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR JS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UT/LIT/ES SHOWN ON THE PLANS ANO ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 9. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXJSnNG FACILITIES (ABOVEGROUND ANO UNDERGROUND) WITHIN THE PROJECT SITE SUFFIC/ENTL Y AHEAD OF THE CONSTRUCT/ON TO PERMIT THE REVISIONS OF THE CONSTRucnoN PLANS IF IT JS FOUND THAT THE ACTUAL LOCA noNS ARE IN CONFLICT WI TH THE PROPOSED WORK. 10. THE CONTRACTOR SHALL NOnFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO FULL WORK/NG DAYS PRIOR TO STARnNG CONSTRUCT/ON NEAR THEIR FACILlnEs ANO SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT SOC&£ AT&T TIME WARNER GABL/: CITY OF CARLSBAD(STREETS ANO STORM DRAIN) 'CITY OF CARLSBAD(SEWER, WATER & RECLA/MED WATER) 11. ITEMS THAT ARE NOT IDENTIFIED AS "TO BE REMOVED" SHALL BE PROTECTED-IN-PLACE. PROJECT LOCATION THE PROJECT IS LOCATED IN A VEN/DA ENCINAS BEGINNING APPROX/MA TEL Y 2,200 FT. SOUTH OF THE PALOMAR AIRPORT ROAD INTERSECTION. THE PIPELINE ALIGNMENT CONTINUES IN A SOUTHERLY DIRECTION FOR APPROX/MA TEL Y 1,000 FT. IN THE AVENIDA ENCINAS R-0-W BEFORE CROSSING TO PARCELS ON THE EAST SIDE OF AVEN/DA ENCINAS INCLUDING APN'S 214-010-95, 214-010-97, 214-031-14, 214-031-13, 214-0Jl-11, AND 214-0J1-09, WHERE IT G[NERALL Y PARALLELS A VEN/DA ENCINAS FOR APPROX/MA TEL Y 1,400 FT. REFERENCE DRAWINGS CITY OF CARLSBAD ORA WINGS 163-4 210-6 232-2 334-1 397-8 40J-1B A VEN/DA ENCINAS IMPROVEMENTS AVEN/DA ENCINAS IMPROVEMENTS A VEN/DA ENCINAS SEWER A VEN/DA ENCINAS WIDEN/NG RECLAIMED WATER IMPROVEMENTS RECLAIMED WATER IMPROVEMENTS 4 70-7 EWPCP OUTFALL 939-7 SEWER REALIGNMENT & MANHOLE REPAIRS LEUCADIA WASTEWATER DRAWINGS • LEUCADIA COUNTY WATER DISTRICT/ENCINITAS SANITARY DISTRICT FORCEMA/N #3 AND SEWER J2; ENGINEER/NG SC/ENCE, INC. SHEET G-25 • WASTEWATER RECLAMATION SYSTEM REACT/VAT/ON, SCHEDULE Ii & Ill, ENGINEERING SCIENCE, INC. SHEET C-2 & C-3 DIGA. H'RT . . --------T.M. DIAL TOLL FREE 1 -800 -227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA HYDROGEN SULFIDE WARNING! (800)422-4133 (800)660-7343 (800)892-0123 (.760)438-7741 [ 760)434-2980 (760)438-2722 SEWER NOTES 1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CJ TY OF CARLSBAD ENG/NEER/NG STANDARDS (LA TEST ED/T/ON), VOLUME /- GENERAL DESIGN STANDARDS, CHAPTER 6-0ES/GN CRITERIA FOR GRAV/TY SEWER LINES AND APPURTENANCES, ANO VOLUME 3 -STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCTION, LA TEST EDITION (GREEN BOOK). 2. BEFORE ANY CONNECTION TO THE EXISTING SEWER SYSTEM, A PERMIT SHALL BE OBTAINED FROM THE CITY. IT MUST BE SIGNED ANO APPROVED BY THE DISTRICT ENGINEER ANO SUPERINTENDENT. 3. EX/STING MANHOLE CONO/T/ONS: A COPY OF THE TECHNICAL MEMORANDUM "OCCIDENTAL LINE-MANHOLE ASSESSMENT" V&A DEC. 15, 2010 HAS BEEN PROVIDED IN THE APPENDIX OF THE CONTRACT DOCUMENTS. DETAILS OF THE EXISTING CONDITION OF EACH MANHOLE IS PROVIDED IN SAID DOCUMENT. PIPELINE CLEANING AND INSPECTION: THE CONTRACTOR SHALL CLEAN THE ENTIRE PIPELINE ALIGNMENT FROM STA. 25+09 TO STA. o+oo REMOVING ALL DEBRIS AND SHALL PROVIDE CCTV INSPECTION OF THAT PIPEUNE AFTER THE COMPLETION OF THE IMPROVEMENTS. CCTV SHALL BE COMPLETED WITH NO WASTEWATER FLOW IN THE PIPE ANO IN ACCORDANCE TO SPECIF/CAT/ON SECTION 15050 OF THIS CONTRACT. PIPELINE CLEANING SHALL BE COMPLETED COM PL YING W1 TH THE REQUIRMENTS OF STANDARDS SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCTION PART 5, SECTION 500. DEBRIS REMOVED FROM THE PIPELINE CLEANING SHALL BE DELIVERED TO THE DES/GNA TED BINS LOCATED AT EWPCF. CONTRACTOR SHALL COORDINATE TH£ DISPOSAL OF DEBRIS WITH EWPCF STAFF PRIOR TO BEGINNING CLEANING WORK ANO SHALL COMPLY WITH DIRECTIONS FROM EWPCF STAFF. WASTEWATER BYPASS & FLOW MANAGEMENT NOTES: 1. CONTRACTOR SHALL PROV/DE A WASTEWATER BYPASS PLAN TO THE CITY AND WILL HAVE THE CITY'S APPROVAL OF THE BYPASS PLAN IN ACCORDANCE WITH CONTRACT SPECIFICATION SECTION 15600 PRIOR TO COMMENCEMENT OF WORK ON THE SEWER. 2. WASTEWATER BYPASS SYSTEM SHALL HAVE SUFFICIENT CAPACITY TO PROVIDE FOR PEAK FLOWS UP TO 9,500 GPM. 3. LEUCADIA WASTEWATER DISTRICT, TH[ CITY OF CARLSBAD, AND THE CITY OF ENCINITAS EACH HAVE LIFT STATIONS WHICH CONTRIBUTE FLOW TO THE OCCIDENTAL INTERCEPTOR SEWER. THE CONTRACTOR SHALL COORDINATE WITH EACH OF THE AGENCIES THROUGH THE CITY OF CARLSBAD'S ENG/NEERING INSPECTION FOR FLOW MANAGEMENT. CROSS REFERENCE SYSTEM SYMBOL _Q__ @ 0 --s-- ~ WM PO<I Q?NV --w --RW-- 0 • 0 G'i 0 • --TEL-- --£-- --GAS-- -X-X-X- LEGEND DESCRIPTION CURB AND GUTTER BERM SIDEWALK MEDIAN PED RAMP STREET LIGHT SIGN STORM DRAIN MANHOLE STORM DRAIN LINE CATCH BASIN CURB INLET SEWER MANHOLE SEWER LINE WATER METER FIRE HYDRANT WATER VALVE WATER LINE RECLAIMED WATER LINE BLOW-OFF ASSEMBLY MANUAL AIR RELEASE ASSEMBLY GATE VALVE GATE POST GUARD POST TELEPHONE MANHOLE TELEPHONE RISER CATV RISER ELECTRIC METER PULL BOX COMMUN/CATION LINE ELECTRICAL LINE GAS LINE EXIST. FENCE EXIST. GUARDRAIL DETAIL • ALL LEGEND SYMBOLS ARE FOR EXISTING UTILITIES ANO STRUCTURES UNLESS OTHERWISE IND/CA TEO. DESIGN CRITERIA OCCIDENTAL INTERCEPTOR SEWER HYDRAULIC CAPACITY REACH STATIONS DIA. PIPE MATERIAL DOWNSTREAM MANHOLE UPSTREAM MANHOLE LENGTH (INCHES) (FEET) CITY MH /OJ INVERT (CENTER) CITY MH /OJ INVERT (CENTER) 1 o+oo TO 10+02 48 RCP (T-LOCK) 35C-2I 26.68 35C-12 28.35 1,002 2 10+02 TO 12+04 42 VCP 35C-12 28.35 35C-11 32.62 202 3 l2·1-04 TO 13+74 39 VCP 35C-11 32.62 35C-13 32.91 170 '3A 13+ 74 TO 20+82 37 VCP (GIPP LINED) 35C-13 32.91 4/A-2 34.25 708 4 20+82 TO 24+90 39 VCP 4/A-2 34.25 41A-3 34.73 408 ' GIPP INSTALLED IN THIS PROJECT RESULTS IN 0/M/N/SHED PIPE DIAMETER FROM 39" TO 37" IN THAT PORTION OF REACH 3 SHOWN ON SHEET 4 FLOW(Q): DERIVED FROM MANNING EQ.; n=0.013; MGO=MILLION GALLONS/DAY SLOPE(S): DERIVED BY (UPSTREAM MANHOLE IE -DOWNSTREAM MANHOLE /E)/L LENGTH(L): CENTER OF UPSTREAM MANHOLE TO CENTER OF DOWNSTREAM MANHOLE MANHOLE INVERT ELEVATIONS (1£) BASED ON; BENCHMARK BM-OC/47, ROS 17217; EL. 50.56; NGVO 29 MSL SLOPE (%) 0.17 2.11 0.17 0.19 0.12 Q -FLOW CAPACITY (MGD) DESIGN MAX. O/d=0.75 O/d=0.94 34.90 41.20 86.13 101.60 20.06 23.67 18.43 21.74 16.86 19.88 ~1<.QfESS/O,y,1( 0' 0' '"' !ff TERRY L. SMITH \ a:::: No. 42979 03/31/12 * EXTREME HEALTH HAZARD. LEVELS UP TO 1,000 PPM OF HYDROGEN SULFIDE GAS (H2S) HAVE BEEN MEASURED IN THIS SEWER. COMPLY WITH OSHNCALOSHA REGULATIONS AND RECOMMENDATIONS AT ALL TIMES. CIVIL~;jll --:?J ,(\~ {,,;..:_ =c I<': - BASIS OF BEARINGS THE HORIZONTAL BASIS OF BEARING FOR THE AERIAL CONTROL SET JS THE LIN£ BETWEEN 'CLSB-047" AND "CLSB-050". THE TWO CONTROL MONUMENTS ARE SHOWN ON RECORD OF SURVEY NO. 17217. THE BEARING BETWEEN "CLSB-047" AND "CLSB-050" IS SOUTH 76" 38' 42" WEST. THE DA TUM JS NA083, CALIFORNIA ZONE 6. TH£ COOROINA TES USED FOR THE POINTS FROM THE RECORD OF SURVEY ARE CCS831991.35. BENCH MARK DESCRIPTION: 0 " .nr-147 LOCATION: NORTHEAST CORNER OF BRIDGE CARLSBAD BLVD ANO PONTO CREEK RECORDED: R. 0. S. 17?1 7 ELEVATION: 50.56 DATUM: NGVO 29 M.S.L. SOURCE OF TOPOGRAPHY THE 2005 CONTOURS REPRESENT LINES CONNECTING EQUAL VALUES OF ELEVATION ABOVE '.jEA LEVEL AND WERE INTERPRETED FROM A LIDAR 0/GITAL TERRAIN MODEL USED TO CREATE ORTHOPHOTOGRAPHY, BASED ON IMAGERY FLOWN IN JULY-AUGUST 2001. THE INTERVAL BETWEEN ADJACENT CONTOURS IS TWO FEET. THE A TTR/BUTE ITEM ELEV IS THE OBSERVED ELEVATION OF TH£ LINE, IN F[ET, GEOTECHNICAL INFORMATION GEO TECHNICAL EVALUATION OCCIDENTAL SEWER REPAIR PROJECT MAY 19, 2011. PROVIDED W1TH CONTRACT DOCUMENTS. WORK TO BE DONE MANHOLE SCHEDULE MH# CITYMHID# STATION IMPROVEMENT 1 35C-21 o+oo REHABILITATE PER DETAIL 1 SHEET 5 (SE£ NOTE 3 BELOW) 2 35C-12 10+02 REHABILITATE PER DETAIL 1 SHEET 5 (SE£ NOTE 3 BELOW) 3 35C-11 12+03 REHABILITATE PER DETAIL 1 SHEET 5 (SEE NOTE 1 BELOW) 4 35C-13 13+74 REHABILITATE PER DETAIL 1 SHEET 5 (SEE NOTES 2 & 4 BELOW) 5 4/A-1 16+86 REHABILITATE PER DETAIL 1 SHEET 5 (SEE NOTES 1, 2 & 4 BELOW) 6 4/A-2 20+82 REHABILITATE PER DETAIL 1 SHEET 5 (SEE NOTES 1 & 4 BELOW) 7 4/A-3 24+90 REHABILITATE PER DETAIL 1 SHEET 5; INSTALL PAMREX 36" COVER W/ SMARTCOVER-S PART#-1002K 8 4/A-4 25+10 REHABILITATE PER DETAIL 1 SHEET 5 PIPELINE & REHABILITATION SCHEDULE, REACH 3A LOCATION IMPROVEMENT LENGTH MATERIAL DIA. STA. 13+73 TO STA. 16+86 INSTALL GIPP PER SPECIF/CAT/ON 13605 (SEE NOTE 1 BELOW) 313 LF STA. 16+86 TO STA. 20+82 INSTALL GIPP PER SPECIF/CATION 13605 (SE£ NOTE 1 BELOW) 396 LF NOTES: 1. COORDINATE ACCESS TO PORTIONS OF THIS PROJECT WHICH ARE ON ENC/NA WASTEWATER AUTHORITY PROPERTY WITH OWNER. NO ACCESS IS ALLOWED PR/OR TO NOTIFICATION AND COORDINATION WITH OWNER. 2. MH#5 (41A-1) HAS ADS FLOW METER WHICH MUST BE REMOVED PRIOR TO CONSTRUCT/ON. CONTRACTOR SHALL PROVIDE NOT/CE TO EWA & ADS 14 DAYS PRIOR TO COMMENCEMENT OF WORK IN THIS MANHOLE ARRANGING IT'S TEMPORARY REMOVAL AND RE-INSTALLATION.CONTACT NEIL VOLKS AT ADS; PH# 858-571-0045 TO SCHEDULE EQUIPMENT REMOVAL ANO RE/NSTALLMENT. CONTRACTOR SHALL SHALL PAY ALL COSTS FRO EQUIPMENT REMOVAL AND REINSTALLMENT. THESE COSTS ARE CONSIDERED INCIDENTAL WORK ANO NO ADDITIONAL PAYMENT WILL BE MADE BY THE CITY THEREFORE. 3. AT THE JUNCTION OF RCP TO THE MANHOLE THE PVC LINER IN TH£ RCP IS OELAMINA TING FROM TH£ PIP£. CONTRACTOR SHALL REPAIR ALL DETERIORATED CONCRETE AND REINSTALL A PVC LINER OVER ALL CONCRETE/ CEMENT SURFACES PER O[TA/Lffi 4. TO PROVIDE ADEQUATE ACCESS FOR GIPP INSTALLATION IN THE PIPELINE, THE MANHOLE ECCENTRIC CONE OR UPPER SLAB MAY NEED TO BE REMOVED. IN THIS CASE CONTRACTOR SHALL REMOVE AND REPLACE THAT UPPER PORTION OF THE MANHOLE AS PART OF THE MANHOLE REHABILITATION PER DETAIL EB ABBREVIATIONS VCP VCP AC -ASPHALT CONCRETE N'LY -NORTHERLY ACP -ASBESTOS CEMENT PIPE N.T.S. -NOT TO SCALE AGG -AGGREGATE OG -ORIGINAL GROUND BCR -BEGIN CURVE RETURN 0/H -OVERHEAD BOP -80 TTOM OF PIPE PB -PULLBOX Jg" 39" BVCE -BEGINNING OF VERTICAL CURVE ELEVA T/ON PC -POINT OF CURVATURE aves -BEGINNING OF VERTICAL CURVE STATION PCC -PORTLAND CEMENT CONCRETE If. -CENTERLINE Pl -PO/NT OF INTERSECTION C/G/SW -CURB, GUTTER, SIDEWALK PROP -PROPOSED ' GATH -CATHODIC PROT -PROTECTION CATV -CABLE TELEVISION PT -POINT OF TANGENCY GIPP -CURED IN PLACE PIPE PVC -POL YV/NYL CHLORIDE CL -CLASS PV/ -POINT OF VERTICAL INTERSECT/ON CML&TC -CEMENT MORTAR LINED & TAPE COATED PVMT -PAVEMENT CMWD -CARLSBAD MUNICIPAL WATER DISTRICT RC -RELA TIV[ COMPACTION DIP ~ DUCTILE IRON PIPE RCP -REINFORCED CONCRETE PIPE DRWY -DRIVEWAY RCW -RECLA/MEO WATER [CR -END CURVE RETURN RP -RAO/US POINT EG -EXISTING GROUND RR -RAILROAD E'LY -EASTERLY R/W -RIGHT OF WAY EP -EDGE OF PAVEMENT RW -RECYCLED WATER ESMT -EASEMENT RWD HOR-REDWOOD HEADER EVCE -END VERTICAL CURVE ELEVATION SOC&£ -SAN DIEGO GAS & ELECTRIC EVCS -END VERTICAL CURVE STAT/ON SEG -SEGMENT E'IIPCF -ENC/NA WATER POLLUTION CONTROL FACILITY SHLDR -SHOULDER EWA -ENC/NA WASTEWATER AUTHOR/TY SIG -SIGNAL EXIST -EXISTING S'LY -SOUTHERLY FL -FLOW LINE SL -STREET LIGHT FOG -FACE OF CURB STA -STATION FRP -FIBERGLASS REINFORCED PLASTIC TC -TOP OF CURB FS -FINISHED SURFACE TEL -TELEPHONE HP -HIGH PRESSURE TM -TRANSMISSION MAIN /£ -INVERT ELEVATION TOP -TOP OF PIPE /MPROV -IMPROVEMENTS TYP -TYPICAL LF -LINEAL FEET VG -VERTICAL CURVE LWD -LEUCADIA WASTEWATER DISTRICT VCP -VITRIFIED CLAY PIPE MAX -MAXIMUM r -WITH MBGR -METAL BEAM GUARD RAIL -WATER LINE MH -MANHOLE W'LY -WESTERLY MIN -M/NUMUM 11 AS BUIL T 11 -;;-;-;C _,,/ .~ 4/~/;-1 RCE4~97't E;p,JP/ l/t ' DA~E I REV!Ev/ED BY• INSPECTOR DATE l------t--t-----------__---,f----+---+----+----I I SH2EET I CITY OF CARLSBAD I SHE5ETS I UTILITIES DEPARTMENT ~M::;PR::::O;:V::;EM::Ec'::N::;T::::PLAN::::::::S::::f;::O::;R:::: :::::::::::::::::::::::::::::'::::=:::=::::===:::"::==~ OCCIDENTAL INTERCEPTOR SEWER REHABILITATION NOTES APPR~VED WILLIAM E. PLUMMER ~.; z::?wwn-::i-/oa~o/ DEPUTY CITY ENGINEER PE 28176 EXPIRES J/31/12 1 ATE DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: " I PROJECT NO. I DRAWING NO. ~~~g ~~; tff _ 5522 _ 472-1 121311 V1 0 :::r ~ ~ G) ,-+ N_p. 0 --..J ....., N V, ' I-' ) -· " ' ·-. - ------ ~ HABITAT AREA NOTES: r + PROTECTION OF EXISTING HABITAT: -_-. -:: ____ , __ -r---.: ----. . - EXISTING HABITAT IS MAPPED ANO SHOWN ON THESE PLANS FOR REFERENCE ONLY. THE PROJECT BIOLOGIST PROV/OED BY THE CITY WILL OELJNEA TE, PRIOR TO THE CONTRACTOR'S MOBILJZA TION FOR THE PROJECT, THE PRECISE LOCA TJON(S) OF HABITAT TO BE A VO/OED THROUGHOUT THE CONSTRUCT/ON OF THIS PROJECT. THE DISTURBED HABITAT AREA ADJACENT TO MH/7 &-MJ-//8 HAS-SUFFICIENT AREA FOR INSTALLATION OF BYPASS PUMPS AND PIPING. ' MIGRATORY BIRD TREATY ACT COMPLIANCE: NO CONSTRUCT/ON ACTIVITY SHALL OCCUR DURING THE PRIME NESTING SEASON BETWEEN FEBRUARY 15 TO AUGUST JI. SHEET 3 REHABILITATION WORK TO BE DONE: 1. REHAB/UTA TE J EACH SEWER MANHOLES (MH/1, MH/2, MH/J) PER DETAIL EB 2. PROVIDE FULL WASTEWATER BYPASS FOR MANHOLE REHAB/UTA TION (FLOW THROUGH PLUGS NOT ALLOWED) J, PERFORM PIPELINE CLEANING AND CCTV INSPECTION STA. o+oo TO STA. 12+95 r - -- r· -,---_----- NOTES: . - ··----I- = --·---___ _ 1. COORDINATE ACCESS TO PORTIONS OF THIS PROJECT WHICH ARE ON ENC/NA WASTEWATER AUTHORITY PROPERTY WITH OWNER. NO ACCESS IS ALLOWED PRIOR TO NOT/FICA TION ANO COORDINATION WITH OWNER. 2. MH/5 (41A-1) HAS ADS FLOW METER WHICH MUST BE REMOVED PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE NOTICE TO EWA &-ADS 14 DAYS PRIOR TO COMMENCEMENT OF WORK IN THIS MANHOLE ARRANGING IT'S TEMPORARY REMOVAL AND RE-INSTALLA T/ON. 3. AT THE JUNCTION OF RCP TO THE MANHOLE THE PVC LINER IN THE RCP IS DELAMINA TING FROM THE PIPE. CONTRACTOR SHALL REPAIR ALL DETER/ORA TED CONCRETE AND REINSTALL A PVC LINER OVER ALL CONCRETE/ CEMENT SURFACES PER DETAIL® 4. TO PROVIDE ADEQUATE ACCESS FOR GIPP /NSTALLA T/ON IN THE PIPELINE, THE MANHOLE ECCENTRIC CONE OR UPPER SLAB MAY NEED TO BE REMOVED. IN THIS CASE CONTRACTOR SHALL REMOVE AND REPLACE THAT UPPER PORTION OF THE MANHOLE AS PART OF THE MANHOLE REHABILITATION PER DETAIL EB HYDROGEN SULFIDE WARNING! _ , EXTREME HEALTH HAZARD. LEVELS UP TO 1,000 PPM OF HYDROGEN SULFIDE GAS (H2S) HAVE BEEN MEASURED IN THIS SEWER. COMPLY WITH OSHNCALOSHA REGULATIONS AND RECOMMENDATIONS AT ALL TIMES. I/ I \ T.M. -· DIAL TOLL FREE 1 -800 -227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA ~ --r--_-_ . --e-------------... ,-.------. -· i--------::--• '' AS BUILT" -;;_j /./,/ ~ "1/4/;4 Rccl:f97"t E;P,-:J/31 / It ' oA'rr: REVJEl,,/ED BY• INSPECTOR DATE f---+---1------------+---+---t----t-----l I SH3EET I CITY OF CARLS BAD I SHE5ETS I UTILITIES DEPARTMENT ~IM:;P::;R:;OV::;E;M~EN~T;:P;:LAN:;::=.S;;F;O:;R.=· ==========-===~ OCCIDENTAL INTERCEPTOR SEWER REHAB/LITA TION PLAN & PROFILE APPRO't_ED WILLIAM L PLUMMER D;;~TY CITY E~G~E;~ 28176 EXPIRES J/Jl/12 1°4~#1 I\ IJS 8U/LT DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DA TE INITIAL DATE INITIAL • >---~--<--~---I OTHER APPROVAL CITY APPROVAL DWN BY: '" I PROJECT NO. I DRAWING NO. CHKD BY: MB 5522 472-1 RVWD BY: TS 121317 Vl 0 :r ~ ~ G) ,....,. W_i:,. 0 -..J -,., N V, I f-' J r---- --_ --I----, - 13 14 HABITAT AREA NOTE: ---I--· --I--- 15 r ----I----- NOTES: 1. ' r ' r ---~---- ,---·· ·1---.::........:... ··- COORDINATE ACCESS TO PORTIONS OF THIS PROJECT WHICH AR[ ON [NC/NA WASTEWATER AUTHORITY PROPERTY 1'11TH OWNER. NO ACCESS IS ALLOWED PRIOR TO NOTIFICATION AND COORDINATION 1'11TH OWNER. ' --··----r ------r ----- i:5l 0' -__ : ____ -=- ?ROfESSJo,v,-,( PROTECTION OF EXISTING HABITAT: 2. MH#5 ( 4/A-1) HAS ADS FLOW METER WHICH MUST BE REMOVED PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE NOTICE TO £WA & ADS 14 DAYS PRIOR TO COMMENCEMENT OF WORK IN THIS MANHOLE ARRANGING IT'S !.:; ~ 0 TERRY L. SMITH <;;\ EXISTING HABITAT IS MAPPED AND SHOWN ON THESE PLANS FOR Rff[R[NC[ ONLY. TH£ PROJECT BIOLOGIST PROVIDED BY TH[ CITY 1'11LL D£UN£AT[, PRIOR TO TH[ CONTRACTOR'S MOBIUZAT/ON FOR TH£ PROJECT, TH£ PRECISE LOCA T/ON(S) OF HABITAT TO 8£ AVOIDED THROUGHOUT TH£ CONSTRUCT/ON.OF THIS PROJECT. TH[ OISWRB[D HABITAT AREA ADJACENT TO MH#l & MH/8 HAS SUFFICIENT AREA FOR INSTALLATION OF BYPASS PUMPS AND PIPING. MIGRATORY BIRD TREATY ACT COMPLIANCE: NO CONSTRUCT/ON ACTIVITY SHALL OCCUR DURING TH[ PRIM[ NESTING SEASON BETWEEN FEBRUARY 15 TO AUGUST JI. SHEET 4 WORK TO BE DONE: 1. REHABIUTAT[ 5 EACH SEWER MANHOLES (MH/4, MH/5, MH/6, MH#l, MH/8) PER DETAIL ffi TEMPORARY REMOVAL AND RE-INSTALLATION. , , • 3. AT TH[ JUNCTION OF RCP TO TH[ MANHOLE TH£ PVC LINER IN TH£ RCP IS DELAMINA TING FROM THE PIPE. ' CONTRACTOR SHALL REPAIR ALL DETERIORATED CONCRETE AND REINSTALL A PVC LINER OVER ALL CONCRETE/ 4. CEMENT SURFACES PER D[TA/Lffi TO PROVIDE AD[QUA TE ACCESS FOR GIPP /NSTALLA TION IN TH£ PIPELINE, TH[ MANHOLE ECCENTRIC CON[ OR UPPER SLAB MAY NEED TO 8£ REMOVED. IN THIS CASE CONTRACTOR SHALL REMOVE AND REPLACE THAT UPPER PORTION OF TH£ MANHOLE AS PART OF THE MANHOLE REHAB/LITA TION PER DETAIL ffi 2. INSTALL 395 L.F. OF GIPP FROM MH/6 TO MH,f5 J. INSTALL 313 L.F. OF GIPP FROM MH,f5 TO MH,f4 4. PIPELINE CLEANING AND CCTV INSPECTION HYDROGEN SULFIDE WARNING! EXTREME HEALTH HAZARD. LEVELS UP TO 1,000 PPM OF HYDROGEN SULFIDE GAS (H2S) HAVE BEEN MEASURED IN THIS SEWER. COMPLY WITH OSHA/CAL OSHA REGULATIONS AND RECOMMENDATIONS AT ALL TIMES. ,., ;o °" No. 42979 11: Exp. 03/31 /12 CIVIL /': / ~v (' .er-. cP-0.1 . DIAL TOLL FREE 1 -800 -227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA -r ~-LiJJvE I? FOR Z-LOiV ZJl:.?11 i'! '!{_'8._'/i/!l.5'.EO(l;V O k//lll_:41/lv'//114-t._--_-~-~--- t_VE ZE R IOR!i T/0/11__-,YQ L/NER. t!ff_CO//TI Nu. WASl#SmLLe-o ------- =111. --c'!ill.!Vilfl-_ tiNO_"S'/l.tlE~llR£/l ------:_--=_·-----~ --_-. - --- - - - ---· ----------- --------- "AS BUILT" ~ -_-z'__,L ~ 4 /4/;4 RCE-1'J"'~7"t E~P. 3/3///t / DA~E . REVIE\,/ED BY• INSPECTOR DATE t-----+----t---------------j-----j---;----;---1 I SH4EET I CITY OF CARLS BAD I SHESETS I UTILITIES DEPARTMENT :;;M;P;R;:OV;E;:M~EN;:;T;:;P;:LAN:;:;:;;S;F;O;R.=-=========:::::'.__'.:::==::; OCCIDENTAL INTERCEPTOR SEWER REHABILITATION PLAN & PROFILE APPROVED 1'11LLIAM~M£R 1/?; //, ot'~fr7NGIN';~RES J/31/12 1<?ort '/ II/\ .45 BUILT DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: ~, PROJECT NO, I DRAWING NO. CHKD BY: MB 5522 472-1 RVWD BY: TS 1213/1 V> 0 :::, ~ ~ G) ,..,. .i:,, .i:,, 0 -..J -+,N V, I I-' j 12' WIDE X 6" THICK CONCRETE COLLAR, CLASS 560-C-J250 WI TH J" ASPHALT CONCRETE OVE:RLA Y (TYPICAL). AMER-PLATE 95 Y PVC SLEEVE . ,. : . . . • • 'I '. ••.·~-..... ~ •• 'I ' ..... : .... . . · •• 4" "": JOINT STRIP PVC LINING --------' STANDARD CAST IRON MANHOLE FRAME &: COVER -SEE DWG. NO. 54. USE CONCRETE • B" MIN. COLLAR WHEN NOT IN PAVEMENT GROUND PRECAST ao· ID FLAT TOP WITH . J6" ACCESS OPENING --~:; VARIABLE A ~ .-. ·' ., INT D TAI BUTn RUBBER SEA ANT 1" WELD STRIP 4• JOINT Sffi/P ROPE r-a·--, 5' DIA. A T WITH ,... CONCRETE RINGS . ~-: ; : .: AS REQUIRED. .;•< MAX.=11", :;-r MIN.=5", · · · TOP=2-2 1/2" RINGS. EXISTING LINING NOTES: INSTALL 1" llfLD STRIPS WHERE T-LOCK IS llfLDED; I.E., TOP OF CHANNEL, SHAFT TO SHELF, TURN BACK TO PIPE FACE, CORNERS, ETC. PVC TURN BACK ON PVC PIPING SHALL BE A MINIMUM OF a•. PVC TURN BACK SHALL BE HELD TIGHT TO PVC PIPING BY 1(2" STEEL BAND WI TH CONTACT CEMEN ADHESIVE: APPLIED TO BOTH SURFACES. NO FLAT SHEET PVC SHALL BE USED. FORM IN T-LOCK OR ARROWLOCK ON SHELF AND CHANNEL. OVERLAP PVC ONTO MANHOLE SHAFT AND CHANNEL LINER; l\fLD TO 80 TH AND COMPLETE WITH 1• llfLD STRIPS . INSTALL NONSKID SURFACE ON MANHOLE SHELF • INSTALL PRE FORMED AMER-PLATE 95Y PVC SLEEVE UNDER FRAME AT TOP OPENING. llfLD 4" JOINT Sffi/PS AND FINISH BOTH EDGES WITH 1• llfLO Sffi/PS. COMPLETE CONCRETE CHANNEL SHALL BE RE-CONSTRUCTED ANO ALL BUT THE LOl\fR 90" SHALL BE T-LOCK Ll,~7,'n,;:c---.,..,-.,,___._,,-.~~ THE "T'S" SHALL RUN VERTICAL "S IN THE MANHOLE SHAFT ANO SHALL Bf,__/<.EY€D /IVTO I" S!JWC/J/' .41 THE TERMINUS OF THE T-LOCK. ~-~, -~ AL~ LINER JOINTS SHALL BE HEAT WELDED BY WELDERS CERTIFIED BY THE PVC MANUFACTURER. LINER WILL BE SPARK TESTED AT 20,000 VOLTS MIN. MANHOLE REHABILITATION NOTES: ~ MANHOLE PROFILE CONTRACTOR SHALL PROVIDE FULL WASTEWATER BYPASS FOR EACH MANHOLE TO BE REHABILITATED IN ORDER TO FULLY ACCESS THE IN TERI OR BASE, CHANNEL AND SHELF OF THE MANHOLE. CLASS C TYPE FIELD MORTAR 2: 1 MASONRY SAND/ PLASTIC CEMENT JOINT DETAIL ALL CONCRETE TO CONCRETE JOINTS SHALL BE NOTCHED NTS . MANHOLE REHABILITATION DI DIAL TOLL FREE 1 • 800 · 227 -2600 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA HYDROGEN SULFIDE WARNING! POWER WASHING OF CONCRETE SURFACES TO BE REPAIRED SHALL BE DONE WI TH A MINIMUM PSI OF 5,000 PSI. AT MANHOLES WHERE IT IS NECESSARY TO REMOVE THE UPPER CONE SECTION OR TOP SLAB TO ACCESS THE LOWER PORTION OF THE MANHOLE OR INSTALL GIPP A NEW PVC LINED REPLACEMENT PRECAST CONE OR SLAB SHALL BE INSTALLED COMPLYING WITH DESIGN REQUIREMENTS G ASTM C47B, C497 AND AC/ JIB. DETAIL@ 3,4 EXTREME HEALTH HAZARD. LEVELS UP TO 1,000 PPM OF HYDROGEN SULFIDE GAS (H2S) HAVE BEEN MEASURED IN THIS SEWER. COMPLY WITH OSHNCALOSHA REGULATIONS AND RECOMMENDATIONS AT ALL TIMES. EXISTING VCP OR RCP DIAMETER VARIES 5 6 B B SECTION(!i) SHELF VARIES PER PIPE DIAMETER 4 MANHOLE REHABILITATION DETAIL NTS . . 6 9 2 B ~½• MIN J OVERLAP DETAIL@ 3,5 TRANSITION FROM MANHOLE TO T-LOCK LINED RCP 2 J 4 TERRY L. SMITH No. 42979 Exp. ~03~/~31~/~12_ 4 • ·4 5 6 . ( • • ·• J SIT QETAlL(D-+-....,, .d • • ••.••• . ' , .. . . . . . 4 ..... . . " . . . " . . . • . . . . ·. . . ... 4 . . ... . . . . ., · 4 · .d 4 . . , . . . . ... . . . . . : ., . . ,• . .· . 4 ... 4;-.. ... . . . • . 4 •• • :,, • • ". . . . . . PVC LINING REHAB INDEX (]) EXISTING CONCRETE BASE ® Q) INSTALL REHAB/UTA TION MORTAR WHEN NECESSARY INSTALL ARROWLOK MASTIC INSTALL ARROW!.OK PVC LINER EXISTING PVC T-LOCK LINER EXISTING CONCRETE MANHOLE SHAFT 5 VARIES PER PIPE DIA. SLOPE = ¼ • PER FOOT J EXISTING PIPE DIA. CHANNEL 4 4 4 J J o· 7 . . . SECTION 8-8 NTS 5 ,! . " . 4 . . • .. '• . " 4 • . , .... • 4 . • • ·<I . 4 4 ' . . J . 4 . .,_ 4 . . . . . . . ".. . . . . ... .· 4'! . ' . . . 4 • .. '4 .. " . . . 6 0 ® ® 0 ® EXISTING UNLINED CONCRETE CHANNEL 1" PVC ,\ELD Sffi/P OVER ARROWLOK/ T-LOCK LAP JOINT EXISTING CONCRETE STRUCTURE--~ ARROW-LOCK MASTIC PRIMER @ EXISTING RCP T-LOCK LINED 6 .. G . \) B ' I ½· MIN ~VERLAP t ,¥9912 MASTIC \• MIN THICKNESS ARROW-LOCK LINING ARROW-LOCK PRIMER #5101 DETAIL 4 NTS 5 .· . .. 4 "'! .•• 4" .•• ·1 . .. . . '! . . 4 .. . ., . . . . . . . . :· . ., -.a· . . .. , ·4 .... :,Jl· .. ,i .; .· . . . 4 4. , . . . " ., . . . . . . . . A. . " •• . . .a, . . .. _,_f ,., 4 ·• 4 .. ' .. • ~ • • A . •: . . • '1 • • . .4 .. . ' . ., . . . " . .. ... . ·4 DETAIL 5 NTS 5 ARROW-LOCK EPOXY MASTIC ARROW-LOCK LINER MINIMUM 1 • SAW CUT NOTE: MAY BE RECESSED REV!Ew'ED BY• INSPECTOR DATE 1---t---+------------j----t--+--+---; I SH5EET I CITY OF CARLSBAD I SHE5ETS I UTILITIES DEPARTMENT :::M::P::::Ro==v::EM==E==NT::::P::::LAN:::::::S::F::::OR==,=========:'===~ OCCIDENTAL INTERCEPTOR SEWER REHABILITATION DETAILS I /.IS 8(1/{. T DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DA TE INITIAL OlHER APPROVAL CITY APPROVAL DWN BY: CHKD BY: MB RVWD BY: rs PROJECT NO. I DRAWING NO. 5522 _ 472-1 • i 1213 I I l/l 0 ::J"" ~ ~ G) ,...,. \ Lr1 +" 0 -...J -,, N Lr1 ' I-'