Loading...
HomeMy WebLinkAboutMS 2019-0003; BMW OF CARLSBAD; CMU RETAINING WALLS AND BMP PLANTERS STRUCTURAL CALCULATIONS; 2020-03-06 Date: March/6/2020 Calculations Prepared By: Reviewed for Geotechnical Conformance By: Matthew Farrington, M.Sc. RCE 90349 Nadim Sunna, M.Sc., PE, GE 3172 Senior Staff Engineer Senior Engineer GMU STRUCTURAL ENGINEERING GMU GEOTECHNICAL, Inc. CMU RETAINING WALLS AND BMP PLANTERS BMW 1050 / 1060 Auto Center Ct. Carlsbad CA STRUCTURAL CALCULATIONS ru1 • 1 '-II ..... ■ STRUCTURAL .... ENGINEER ING Table of Contents Page # Description Sheet 1 BMP Planter Stem Wall Loading NA 2 BMP Planter Stem Wall Check NA 3 BMP Planter Base Loading NA 4 BMP Planter Base Check NA 5 – 9 Detail 1, Civil Section D-D, Retaining Wall, Adj. Auto Center Court S-1 10 – 14 Detail 2, Civil Section G-G, Retaining Wall Adj. Auto Center Court S-1 15 – 19 Detail 3, Civil Section J-J, Retaining Wall Adj. Cannon Road S-1 20 – 24 Detail 4, Civil Section I-I, Retaining Wall Adj. Cannon Road S-1 25 – 29 Detail 5, Civil Section A-A, BMP Planter, Western Edge of Site S-1 30 – 34 Detail 6, Civil Section B-B, BMP Planter, Northern Side Adj. Cannon Road S-2 35 – 39 Detail 7, Civil Section E-E, BMP Planter, NE Corner Adj. Car Country Drive, Parking Lot Side of Structure. S-2 40 – 44 Detail 7, Civil Section E-E, BMP Planter, NE Corner Adj. Car Country Drive, Sidewalk Side S-2 45 – 49 Detail 8, Civil Section F-F, BMP Planter, Southern Corner Adj. Car Country Drive and Auto Center Court, Parking Lot Side of Structure S-2 50 – 54 Detail 8, Civil Section F-F, BMP Planter, Southern Corner Adj. Car Country Drive and Auto Center Court, Slope Side of Structure S-2 55 – 59 Detail 9, Civil Section H-H, BMP Planter, NE Corner Adj. Cannon Road, Parking Lot Side of Structure S-2 60 – 64 Detail 9, Civil Section H-H, BMP Planter, NE Corner Adj. Cannon Road, Slope Side of Structure S-2 ru1 1 I STRUCTURAL '-11 ... ILI ENGINEER ING Design Parameters, Per Soils Report “Geotechnical Investigation Report Auto Nation BMW of Carlsbad 1050 and 1060 Auto Center Court, Carlsbad California, Dated December 13, 2019. By GMU Geotechnical, GMU Project Number 18-101-00 • Bearing Materials: o 3 feet of engineered fill below bottom of footing for all walls and BMP structures where footings span from cut to fill. The cut should be excavated to a depth of 3’ below footing elevation and must be compacted to 90% relative compaction in accordance with ASTM D1557. o Competent Santiago Formation bedrock for all retaining walls and BMP structures in cut. • Active Loading: o 35 PCF (EFP) – Assumes the use of select soils in backfill zone, (Drained). o 80 PCF (EFP) – Saturated soil condition, (undrained) – (Calculated by GMU Structural) • Soil Friction Angle, (Phi): o 33 degrees • Unit Weight of Soil (Gamma): o 120 PCF • Passive Resistance: o 300 PSF level ground ▪ Ignore Upper 6” of passive resistance ▪ 1/3 allowable increase for seismic conditions o 100 PSF sloping ground – Per conversation with Nadim Sunna, GMU Geotechnical – to be included in an addendum by GMU Geotechnical to be released later. o 400 PSF (300 + 1/3 Increase) for retaining walls and BMP Planters in Santiago Formation bedrock per Nadim Sunna GMU Geotechnical – to be included in an addendum to be released at a later date. • Maximum Bearing Capacity: o 2,500 PSF ▪ 1/3 allowable increase for seismic conditions • Coefficient of Friction: - 0.30 Additional Loading Specifications • All retaining walls and BMP Structures that abut the BMW dealership parking lot include a surcharge load of 250 psf, (Minimum Passenger Car Load Per ASCE 7-16). • Cast-in-Place BMP Planters wall and base loading is based on worst case scenario (system being clogged). Saturated Soil 80 PSF (EFP) ,-u1 • 1 STRUCTURAL '-11·1u N N IN Minimum Factors of Safety Per 2019 CBC, 1807.2.3 (Safety Factor) Retaining Walls shall be designed to resist the lateral action of soil to produce sliding and overturning with a minimum safety factor of 1.5 in each case. ,-u1 • 1 STRUCTURAL '-11·1u N N IN BMP Planter Stem Wall (LOADING) ∅=33° 𝐾𝑎=𝐴𝑘𝑟𝑘𝑘𝑘𝑍′𝑟𝐴𝑍𝑟�ℎ𝑟𝑍 𝐴𝑍𝑟𝑟� 𝐾𝑟𝑍𝑟𝑟𝑟𝑟𝑍= 0.295 𝛾=120𝑘𝑍𝑍 𝐴=5.25′(𝐴�ℎ𝑍�𝑍𝑟𝑟 𝑅𝑍𝑟𝑍�ℎ𝑘𝑍𝑍 𝑅𝑍𝑍𝑟�ℎ𝑘𝑘). 𝐴𝑍𝑟�ℎ𝑟𝑍 𝐾𝑟𝑍𝑟𝑟𝑟𝑟𝑍=(𝐾𝑎)(𝛾)=35𝐾𝑅𝐴/𝐴𝑅 (𝐴𝐴𝐾) - (DRAINED) 𝐴𝑍𝑟�ℎ𝑟𝑍 𝐾𝑟𝑍𝑟𝑟𝑟𝑟𝑍= 𝐾𝑎(𝛾− 𝛾𝑤)+ 𝛾𝑤=79.4 𝑘𝑍𝑍 ∴𝑅𝑟𝑍 80𝑘𝑍𝑍 (UNDRAINED) 5.25’ Tall Wall 𝐾𝑎= 1 2⁄(80𝐾𝑅𝐴)(5.25 𝑍𝑟)2 =1240.3 𝑘𝑍𝑟 Q. 1,240.3 lbs/FT r:i in 472. 5 PSF/FT u Moment= 2,170.5 ft*lbs Mu= 1.4 x 2,170.5 ft*lbs = 3,038.7 ft*lbs Mu = 36,464.8 in*lbs ru1 1 I STRUCTURAL '-11 ... ILI ENGINEER ING BMP Planter Stem (WALL CHECK) - Modeled as 12” wide Reinforced Concrete Beam, 6” thick 𝑍𝑦=60,000𝐾𝑅𝐴 𝑍=12" �=6" 𝑍=3" 𝐴𝑠=(1)# 5 @ 12" 𝐾.𝐴.= 0.3068 �ℎ𝑘2 𝑍′ 𝑐=3,000𝐾𝑅𝐴 𝐾𝑘𝑍𝑍�ℎ𝑘𝑍 (𝑊𝑘𝑟𝑟𝑟 𝐴𝑍𝑟𝑍 𝑅𝑍𝑍𝑘𝑍𝑟�ℎ𝑘)=𝐴𝑘𝑘𝑟𝑟 𝐴𝐾𝐾 𝑟𝑟𝑟𝑟𝑍𝑟𝑟𝑟𝑍 𝑟𝑍𝑟𝑍�ℎ𝑘�ℎ𝑘𝑍 𝑟𝑘𝑍𝑟𝑍�ℎ𝑘𝑍𝑍 𝑟𝑘�ℎ𝑘𝑟 𝐾𝑢=(3,038.7 𝑍𝑟∗𝑘𝑍𝑟)=36,464.8 �ℎ𝑘∗𝑘𝑍𝑟 𝜌= 𝐴𝑠 𝑍𝑍= 0..3068 �ℎ𝑘2 12" ∗ 3"=0.008572 𝐴𝑠min =0.0033 𝑍𝑍=0.1188 �ℎ𝑘2 𝐴𝑠=0.3068 �ℎ𝑘2 >0.1188 �ℎ𝑘2 ∴ 𝐾𝐾 ∅=0.9 𝑘−=0.4590 𝑘�ℎ𝑘𝑟 �ℎ𝑘2⁄ 𝑍= 𝐴𝑠𝑍𝑦 0.85 𝑍′ 𝑐𝑍=0.602 �ℎ𝑘 𝑍=𝑍−𝑍2⁄=2.7 �ℎ𝑘 𝐾𝑛= 𝐴𝑠𝑍𝑦𝑍=49,687.2 �ℎ𝑘∗ 𝑘𝑍𝑟−𝐴𝐴𝑅𝐴𝐴 𝐾𝐾 𝑅𝑅𝐴𝐴𝐾 ∅𝐾𝑛=44,718.4 �ℎ𝑘∗𝑘𝑍𝑟= 3,726.5𝑍𝑟∗𝑘𝑍𝑟 𝐾𝑛= ∅𝑍𝑍2𝑘−=(0.9)(12�ℎ𝑘)(3�ℎ𝑘)2 (0.4590 𝑘�ℎ𝑘𝑟 �ℎ𝑘2⁄)=44,615 �ℎ𝑘∗𝑘𝑍𝑟− 𝐴𝐴𝑅𝐴𝐴 𝐾𝐾 𝑘− ∅𝐾𝑛=40,153.3 �ℎ𝑘∗𝑘𝑍𝑟= 3,346.1𝑍𝑟∗𝑘𝑍𝑟 𝐾𝑢∅𝐾𝑛⁄= 36,464.8 �ℎ𝑘∗𝑘𝑍𝑟 40,153.3 �ℎ𝑘∗𝑘𝑍𝑟⁄=90.8 % 𝑅𝑟𝑟𝑍𝑟𝑟 𝑅𝑍𝑟�ℎ𝑘 ∴𝐾𝐾 ru1 1 I STRUCTURAL '-11 ... ILI ENGINEER ING BMP PlanterBase (LOADING) Loading (Worst Case Scenario) – Fully clogged system with undrained soils 𝛾′= (𝐴𝑠+𝑍)𝛾𝑤 (1 +𝑍)= (2.65 +.15)62.4𝐾𝐴𝐴 (1 +0.15)=151.9𝐾𝐴𝐴 (151.9 𝐾𝐴𝐴)(1′𝑟�ℎ𝑍𝑍)(4.25′ 𝑖ℎ𝑍�)=645.6𝐾𝑅𝐴 𝑊𝑘2 12 = 645.6 𝐾𝐾𝐴 (4 𝑍𝑟2) 12 =860.8 𝑍𝑟∗ 𝑘𝑍𝑟=10,329.2 �ℎ𝑘∗𝑘𝑍𝑟 𝐾𝑢=1.4(860.8 𝑍𝑟∗𝑘𝑍𝑟)=1,205.1 𝑍𝑟∗𝑘𝑍𝑟 𝐾𝑢=14,461.4 �ℎ𝑘∗𝑘𝑍𝑟 646 PLF Q ' ~ ' u Moment = 860.8 ft*lbs Mu = 1.4 x 860.8 ft*lbs 1,205.1 ft*lbs = 14,461.4 in*lbs ru1 1 I STRUCTURAL '-11 ... ILI ENGINEER ING BMP Planter (BASE CHECK) - Modeled as 12” wide Reinforced Concrete Beam, 12” thick 𝑍𝑦=60,000𝐾𝑅𝐴 𝑍=12 , h = 12, 𝑍=6", ∅ = 0.9 𝐴𝑠=(1)# 5 @ 12" 𝐾.𝐴.= 0.307 �ℎ𝑘2 𝑍′ 𝑐=3,000 𝐾𝑅𝐴 𝐾𝑘𝑍𝑍�ℎ𝑘𝑍 (𝑊𝑘𝑟𝑟𝑟 𝐴𝑍𝑟𝑍 𝑅𝑍𝑍𝑘𝑍𝑟�ℎ𝑘)=𝑅𝑍𝑍𝑟𝑍𝑘𝑍𝑟𝑘𝑍𝑟 𝐾𝑘𝑍𝑍�ℎ𝑘𝑍 775 𝐾𝑅𝐴 𝐾𝑢=1,205.1 𝑍𝑟∗𝑘𝑍𝑟=14,461 �ℎ𝑘∗𝑘𝑍𝑟 𝜌= 𝐴𝑠 𝑍𝑍= 0.307 �ℎ𝑘2 12" ∗ 6"=0.00426 𝐴𝑠min =0.0033 𝑍𝑍=0.1188 �ℎ𝑘2 𝐴𝑠=0.307 �ℎ𝑘2 >0.1188 �ℎ𝑘2 ∴ 𝐾𝐾 𝑍= 𝐴𝑠𝑍𝑦 0.85 𝑍′𝑐𝑍=0.6019 �ℎ𝑘 𝑍=𝑍−𝑍2⁄=5.7 �ℎ𝑘 𝐾𝑛= 𝐴𝑠𝑍𝑦𝑍=104,976 �ℎ𝑘∗ 𝑘𝑍𝑟−𝐴𝐴𝑅𝐴𝐴 𝐾𝐾 𝑅𝑅𝐴𝐴𝐾 ∅𝐾𝑛=94,478.3 �ℎ𝑘∗𝑘𝑍𝑟=7,873.2 𝑍𝑟∗𝑘𝑍𝑟 𝐾𝑛= ∅𝑍𝑍2𝑘−=(0.9)(12�ℎ𝑘)(6�ℎ𝑘)2 (0.2396 𝑘�ℎ𝑘𝑟 �ℎ𝑘2⁄)=93,156.5 �ℎ𝑘∗𝑘𝑍𝑟− 𝐴𝐴𝑅𝐴𝐴 𝐾𝐾 𝑘− ∅𝐾𝑛=83,840.8 �ℎ𝑘∗𝑘𝑍𝑟= 6,986.7𝑍𝑟∗𝑘𝑍𝑟 𝐾𝑢∅𝐾𝑛⁄= 14,461.4 �ℎ𝑘∗𝑘𝑍𝑟83,840.8 �ℎ𝑘∗𝑘𝑍𝑟⁄=17.3 % 𝐾𝑍𝑟�ℎ𝑘𝑟𝑘 𝐴𝑍𝑘𝑍�ℎ𝑘𝑍 𝑅𝑟𝑟𝑍𝑟𝑟 𝑅𝑍𝑟�ℎ𝑘 ∴𝐾𝐾 ru1 1 I STRUCTURAL '-11 ... ILI ENGINEER ING 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.70 0.25 0.00 24.00 2,500.0 90.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft Used To Resist Sliding & Overturning Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.64 OK Sliding =1.69 OK Total Bearing Load =1,323 lbs...resultant ecc.=11.38 in Soil Pressure @ Toe =1,303 psf OK Soil Pressure @ Heel =0 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,824 psf ACI Factored @ Heel =0 psf Footing Shear @ Toe =4.4 psi OK Footing Shear @ Heel =0.0 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =924.8 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 396.9 1,166.7 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Masonry Thickness =6.00Rebar Size =#5 Rebar Spacing =16.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.828 Total Force @ Section =616.1lbs Moment....Actual =759.8ft-# Moment.....Allowable =916.7 =9.1psi Shear.....Allowable =44.6psi Wall Weight =58.0psf Rebar Depth 'd'=2.75in Masonry Data f'm =1,500psi Fs =psi 20,000 Solid Grouting =Yes Modular Ratio 'n'=21.48 Short Term Factor =1.000 Equiv. Solid Thick.=5.60in Concrete Dataf'c =psi Fy = Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =lbsStrength Level Service Level Strength Level =ft-# Service Level Strength Level =psi Design Method =ASD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=67.50in2 Page : 1 Detail 1 Page : 5 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section D-D ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING ~------.. • ~I---------• ~------.. • '--.I---------• l~ ______ _.1 I ~------·•------------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 2.75 0.50 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 12.00 0.00 0.00 ft Footing Thickness =in 3.25= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = No key defined Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way ShearAllow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = == 1,824 46,075 22,275 1,983 4.3575.00 Heel: 0 0 0 0 0.000.00 HeelToe psf ft-# ft-# ft-# psipsi Heel Reinforcing =# 5 @ 16.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 16.00 in Min footing T&S reinf AreaMin footing T&S reinf Area per foot If one layer of horizontal bars: 0.700.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance MomentItemForceft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 687.5 1.38 945.3= = = Stem Weight(s) = 229.1 3.00 687.3 Earth @ Stem Transitions =Footing Weight = 406.3 1.63 660.2 Key Weight = 0.50 Added Lateral Load lbs =1,397.5 Vert. Component Total = 1,322.9 2,292.8* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =924.8 O.T.M. = Resisting/Overturning Ratio =1.64 Vertical Loads used for Soil Pressure =1,322.9 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 924.8 1.51 1,397.5 Hydrostatic Force Page : 2 Detail 1 Page : 6 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section D-D ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.044 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 1 Page : 7 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section D-D ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 1 Page : 8 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section D-D ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING 6" w/ #5@ 16' .. Solid Grout 2'-0" #5@16.in @Toe #5@16" @ Heel • 2'-9" - 3'-3" 6" - - T 2" ___j_ 3" 3'-8" 3'-11" 3" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 1 Page : 9 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section D-D ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 1166.67# -IJ) 0. <D 0 (') 0 (') r 925# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 5.95 0.50 0.00 16.00 2,500.0 35.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =2.83 OK Sliding =3.46 OK Total Bearing Load =2,689 lbs...resultant ecc.=6.17 in Soil Pressure @ Toe =1,445 psf OK Soil Pressure @ Heel =91 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =2,023 psf ACI Factored @ Heel =128 psf Footing Shear @ Toe =17.1 psi OK Footing Shear @ Heel =8.5 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =805.2 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 806.6 1,979.2 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 2nd Bottom Stem OK Stem OK Shear.....Actual Design Height Above Ftg =2.50ft 0.00 Wall Material Above "Ht"=Masonry Masonry Thickness =6.00 8.00Rebar Size =##4 5 Rebar Spacing =32.00 16.00 Rebar Placed at =Center CenterDesign Data fb/FB + fa/Fa =0.765 0.965 Total Force @ Section =208.3 619.5lbs Moment....Actual =239.5 1,228.8ft-# Moment.....Allowable =313.1 1,272.4ft-# =3.1 6.8psi Shear.....Allowable =44.6 45.1psi Wall Weight =58.0 78.0psf Rebar Depth 'd'=2.75in 3.75 Masonry Data f'm =1,500 1,500psi Fs =psi 20,000 20,000 Solid Grouting =Yes Yes Modular Ratio 'n'=21.48 21.48 Short Term Factor =1.000 1.000 Equiv. Solid Thick.=5.60 7.60in Concrete Dataf'c =psi Fy = Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =776.3lbsStrength Level Service Level Strength Level =970.3ft-# Service Level Strength Level =21.6psi Design Method =ASD ASD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=67.50 91.50in2 Page : 1 Detail 2 Page : 10Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section G-G ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING ~------.. • ~I---------• ~------.. • '--.I---------• l~ ______ _.1 I ~-----.. •------------ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 1.00 2.50 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 12.00 18.00 0.00 ft Footing Thickness =in 3.50= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way ShearAllow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = == 2,023 11,055 2,800 688 17.1275.00 Heel: 128 771 2,071 1,299 8.5275.00 HeelToe psf ft-# ft-# ft-# psipsi Heel Reinforcing =# 5 @ 16.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 16.00 in Min footing T&S reinf AreaMin footing T&S reinf Area per foot If one layer of horizontal bars: 0.760.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance MomentItemForceft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 166.7 0.50 83.3= = = Stem Weight(s) = 424.1 1.29 546.4 Earth @ Stem Transitions = 71.9 1.58 113.8 Footing Weight = 437.5 1.75 765.6 Key Weight = 225.0 0.50 112.5 Added Lateral Load lbs =1,820.7 Vert. Component Total = 2,688.7 5,144.1* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =805.2 O.T.M. = Resisting/Overturning Ratio =2.83 Vertical Loads used for Soil Pressure =2,688.7 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,363.5 2.58 2.58 3,522.5 3,522.5 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 805.2 2.26 1,820.7 Hydrostatic Force Page : 2 Detail 2 Page : 11 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section G-G ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.074 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 2 Page : 12 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section G-G ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 2 Page : 13 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section G-G ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 6"w/#4@32" Solid Grout 8"w/#5@ 16" Solicl Grout 1·-4·__._! _ #5@16.in @Toe #5@16" @ Heel 1'-0" 6'-5" 5'-11" 3" 1'-6" 2'-6" 2'-6" 3'-6" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 2 Page : 14 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section G-G ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 1979.17# 805# -"' D.. D D l!) st st -,,, D.. 0) "' m ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 4.85 0.50 0.00 24.00 2,500.0 35.0 0.0 100.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 250.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft Used To Resist Sliding & Overturning Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =2.54 OK Sliding =1.78 OK Total Bearing Load =2,867 lbs...resultant ecc.=6.81 in Soil Pressure @ Toe =1,616 psf OK Soil Pressure @ Heel =22 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =2,263 psf ACI Factored @ Heel =30 psf Footing Shear @ Toe =17.9 psi OK Footing Shear @ Heel =13.5 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =963.1 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 860.0 855.6 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 2nd Bottom Stem OK Stem OK Shear.....Actual Design Height Above Ftg =2.50ft 0.00 Wall Material Above "Ht"=Masonry Masonry Thickness =6.00 8.00Rebar Size =##4 6 Rebar Spacing =32.00 16.00 Rebar Placed at =Center CenterDesign Data fb/FB + fa/Fa =0.859 0.859 Total Force @ Section =261.1 751.1lbs Moment....Actual =269.0 1,488.8ft-# Moment.....Allowable =313.1 1,732.9ft-# =3.9 8.2psi Shear.....Allowable =44.3 44.9psi Wall Weight =58.0 78.0psf Rebar Depth 'd'=2.75in 3.75 Masonry Data f'm =1,500 1,500psi Fs =psi 20,000 20,000 Solid Grouting =Yes Yes Modular Ratio 'n'=21.48 21.48 Short Term Factor =1.000 1.000 Equiv. Solid Thick.=5.60 7.60in Concrete Dataf'c =psi Fy = Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =776.3lbsStrength Level Service Level Strength Level =970.3ft-# Service Level Strength Level =21.6psi Design Method =ASD ASD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=67.50 91.50in2 Page : 1 Detail 3 Page : 15Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section J-J ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING ~------.. • ~I---------• ~------.. • '--.I---------• l~ ______ _.1 I ~------·•------------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 1.00 2.50 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 12.00 16.00 0.00 ft Footing Thickness =in 3.50= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way ShearAllow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = == 2,263 12,301 3,600 725 17.8775.00 Heel: 30 706 2,537 1,831 13.4975.00 HeelToe psf ft-# ft-# ft-# psipsi Heel Reinforcing =# 6 @ 16.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 6 @ 16.00 in Min footing T&S reinf AreaMin footing T&S reinf Area per foot If one layer of horizontal bars: 0.760.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance MomentItemForceft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,130.52.84397.8=Surcharge over Heel = Surcharge Over Heel = 458.3 2.58 1,184.0= Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 250.0 0.50 125.0= = = Stem Weight(s) = 360.3 1.30 466.6 Earth @ Stem Transitions = 49.0 1.58 77.5 Footing Weight = 437.5 1.75 765.6 Key Weight = 200.0 0.50 100.0 Added Lateral Load lbs =2,201.4 Vert. Component Total = 2,866.6 5,590.1* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =963.1 O.T.M. = Resisting/Overturning Ratio =2.54 Vertical Loads used for Soil Pressure =2,866.6 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,111.5 2.58 2.58 2,871.3 2,871.3 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 565.3 1.89 1,070.8 Hydrostatic Force Page : 2 Detail 3 Page : 16 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section J-J ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.069 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 3 Page : 17 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section J-J ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 3 Page : 18 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section J-J ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 2'-o· 6"w/#4@32" Solid Grout 8" w/ #6@ 16" lid Grout #6@16.in @Toe #6@16" @Heel 5·-4· 4'-10" 3• 1'-4" 1'-0" 2'-6" 2'-6" 3'-6" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 3 Page : 19 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section J-J ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 855_56# -"' o_ CD N CD CD 250_00psf ill -"' o_ If) ": N 963# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 5.33 0.17 0.00 24.00 2,500.0 35.0 0.0 100.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 124.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft Used To Resist Sliding & Overturning Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =2.76 OK Sliding =1.57 OK Total Bearing Load =2,220 lbs...resultant ecc.=5.42 in Soil Pressure @ Toe =1,253 psf OK Soil Pressure @ Heel =113 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,755 psf ACI Factored @ Heel =158 psf Footing Shear @ Toe =9.1 psi OK Footing Shear @ Heel =6.0 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =701.2 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 666.1 437.5 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 2nd Bottom Stem OK Stem OK Shear.....Actual Design Height Above Ftg =2.50ft 0.00 Wall Material Above "Ht"=Masonry Masonry Thickness =6.00 6.00Rebar Size =##4 5 Rebar Spacing =32.00 16.00 Rebar Placed at =Center CenterDesign Data fb/FB + fa/Fa =0.422 0.963 Total Force @ Section =140.2 497.2lbs Moment....Actual =132.2 883.3ft-# Moment.....Allowable =313.1 916.7ft-# =2.1 7.4psi Shear.....Allowable =44.3 45.0psi Wall Weight =58.0 58.0psf Rebar Depth 'd'=2.75in 2.75 Masonry Data f'm =1,500 1,500psi Fs =psi 20,000 20,000 Solid Grouting =Yes Yes Modular Ratio 'n'=21.48 21.48 Short Term Factor =1.000 1.000 Equiv. Solid Thick.=5.60 5.60in Concrete Dataf'c =psi Fy = Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =776.3lbsStrength Level Service Level Strength Level =970.3ft-# Service Level Strength Level =21.6psi Design Method =ASD ASD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=67.50 67.50in2 Page : 1 Detail 4 Page : 20 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section I-I ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING ~--------• ~I---------• ~--------• L-.1 ---------• ~I ______ .... 1 I ~--------•------------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 1.00 2.25 12.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 0.00 0.00 1.08 ft Footing Thickness =in 3.25= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = No key defined Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way ShearAllow 1-Way Shear Toe:#4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 =None Spec'd = = = == 1,755 9,546 3,600 495 9.1175.00 Heel: 158 681 1,714 1,033 6.0175.00 HeelToe psf ft-# ft-# ft-# psipsi Heel Reinforcing =# 6 @ 16.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 6 @ 16.00 in Min footing T&S reinf AreaMin footing T&S reinf Area per foot If one layer of horizontal bars: 0.840.26 #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in in2in2 /ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in supplemental design for footing torsion. Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance MomentItemForceft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 248.0 0.50 124.0= = = Stem Weight(s) = 319.0 1.25 398.8 Earth @ Stem Transitions =Footing Weight = 487.5 1.63 792.2 Key Weight = 1.08 Added Lateral Load lbs =1,479.5 Vert. Component Total = 2,220.4 4,084.0* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =701.2 O.T.M. = Resisting/Overturning Ratio =2.76 Vertical Loads used for Soil Pressure =2,220.4 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,165.9 2.38 2.38 2,769.1 2,769.1 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 701.2 2.11 1,479.5 Hydrostatic Force Page : 2 Detail 4 Page : 21Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section I-I ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.059 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 4 Page : 22 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section I-I ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 4 Page : 23 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section I-I ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 2'-0" 6"w/#4@ 32" Solid Grout 6" w/ #5@ 16" lid Grout #6@16_in @Toe #6@16" @Heel • 1'-0" 3'-3" 2" 3'-0" 5'-4" 5'-6" 2'-6" 2" • 3" 2'-3" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 4 Page : 24 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section I-I ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 437.50# 'ti a. r-(') (') L[) N 701# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.58 0.25 0.00 0.00 2,500.0 90.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =12.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 240.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.77 OK Sliding =0.52 UNSTABLE! Total Bearing Load =1,652 lbs...resultant ecc.=1.39 in Soil Pressure @ Toe =399 psf OK Soil Pressure @ Heel =297 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =680 psf ACI Factored @ Heel =506 psf Footing Shear @ Toe =13.9 psi OK Footing Shear @ Heel =9.0 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,639.1 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 789.3= 495.7 354.2 = = 1,608.8 - lbs lbs lbs NG lbs NG - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.781 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,912.6lbsStrength Level Service Level Strength Level =2,872.9ft-# Service Level Strength Level =53.1psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 5 Page : 25 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section A-A ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING • • • ~-------• '--.I---------• I~-------• I ~------... •-------------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2381 in2/ft (4/3) * As :0.3175 in2/ft Min Stem T&S Reinf Area 0.552 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2381 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 2.75 2.00 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0012.00 2.75 ft Footing Thickness =in 4.75= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 680 29,326 6,806 1,877 13.86 75.00 Heel: 506 590 1,205 615 8.95 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 6 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 6 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.03 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 5 Page : 26Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section A-A ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,682.92.21762.6=Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 287.3 3.00 861.8 Earth @ Stem Transitions =Footing Weight = 593.8 2.38 1,410.2 Key Weight = 100.0 3.08 308.3 Added Lateral Load lbs =2,972.3 Vert. Component Total = 1,652.3 5,265.2 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,639.1 O.T.M. = Resisting/Overturning Ratio =1.77 Vertical Loads used for Soil Pressure =1,652.3 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 671.3 4.00 4.00 2,685.0 2,685.0 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 876.5 1.47 1,289.4 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.009 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 5 Page : 27 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section A-A ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 5 Page : 28 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section A-A ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 6"w/#5@ 12· • 3'-7" 3'-10" • • T 2· • • 10 #6@12.in @Toe 3" 1'-0" #6@12" @Heel 2'-9" s· 1•-4• 2'-9" 4'-9" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: u:\2020\20-150-00 bmw carlsbad_structural services\structural\retain-pro - enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 5 Page : 29 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section A-A ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 354_17# ~ -,,, (l_ t-(0 (D 0) "' 240_00psf ill ,,, (l_ N 0 t-o, N 1639# ■ Hydrostatic Force ■ Lateral earttl pressure due to ttle soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.60 0.25 0.00 0.00 2,500.0 90.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =12.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 240.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.51 OK Sliding =0.50 UNSTABLE! Total Bearing Load =1,595 lbs...resultant ecc.=4.42 in Soil Pressure @ Toe =571 psf OK Soil Pressure @ Heel =180 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =979 psf ACI Factored @ Heel =309 psf Footing Shear @ Toe =15.2 psi OK Footing Shear @ Heel =10.8 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,650.5 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 817.9= 478.5 354.2 = = 1,643.1 - lbs lbs lbs NG lbs NG - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.792 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,928.4lbsStrength Level Service Level Strength Level =2,911.3ft-# Service Level Strength Level =53.6psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 6 Page : 30 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section B-B ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING ~-------• '--.I---------• I~-------• I ~------... •-------------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2413 in2/ft (4/3) * As :0.3217 in2/ft Min Stem T&S Reinf Area 0.554 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2413 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 2.25 2.00 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0012.00 3.00 ft Footing Thickness =in 4.25= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 979 26,148 4,556 1,799 15.21 75.00 Heel: 309 436 1,208 772 10.78 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.92 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 6 Page : 31 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section B-B ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,698.12.22766.1=Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 288.8 2.50 721.9 Earth @ Stem Transitions =Footing Weight = 531.3 2.13 1,128.9 Key Weight = 100.0 3.33 333.3 Added Lateral Load lbs =3,005.2 Vert. Component Total = 1,595.0 4,546.6 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,650.5 O.T.M. = Resisting/Overturning Ratio =1.51 Vertical Loads used for Soil Pressure =1,595.0 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 675.0 3.50 3.50 2,362.5 2,362.5 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 884.5 1.48 1,307.0 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.014 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 6 Page : 32Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section B-B ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 6 Page : 33 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section B-B ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING 6" w/#5@ 12" #5@12.in @Toe #5@12" @Heel • • • 3'-0" 2'-3" 4'-3" 3'-7" 3'-10" T 2" 3" 1'-0" 8" 7" 2'-0" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 6 Page : 34 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section B-B ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 354_17#~ 240_00psf ill 1651# ■ Hydrostatic Force ! ■ Lateral earth pressure due to the soil BELOW water table D D ro 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.60 0.50 0.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 240.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.59 OK Sliding =1.58 OK Total Bearing Load =2,166 lbs...resultant ecc.=4.97 in Soil Pressure @ Toe =878 psf OK Soil Pressure @ Heel =205 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,570 psf ACI Factored @ Heel =366 psf Footing Shear @ Toe =7.9 psi OK Footing Shear @ Heel =9.2 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,650.5 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 649.8 1,955.6 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.792 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,928.4lbsStrength Level Service Level Strength Level =2,911.3ft-# Service Level Strength Level =53.6psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 7 - PL Page : 35 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING I • I • n - ~ .1 ~ ~-------• '--.I ______ __.1 I~-------• I ~-----.. •----------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2413 in2/ft (4/3) * As :0.3217 in2/ft Min Stem T&S Reinf Area 0.590 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2413 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 3.00 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0028.00 1.00 ft Footing Thickness =in 4.00= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 1,570 8,817 900 660 7.94 75.00 Heel: 366 1,928 3,356 1,428 9.21 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.86 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 7 - PL Page : 36 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,698.12.22766.1=Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 307.5 1.25 384.4 Earth @ Stem Transitions =Footing Weight = 500.0 2.00 1,000.0 Key Weight = 233.3 1.33 311.1 Added Lateral Load lbs =3,005.2 Vert. Component Total = 2,165.8 4,789.2 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,650.5 O.T.M. = Resisting/Overturning Ratio =1.59 Vertical Loads used for Soil Pressure =2,165.8 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,125.0 2.75 2.75 3,093.8 3,093.8 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 884.5 1.48 1,307.0 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.025 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 7 - PL Page : 37Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 7 - PL Page : 38 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING G" w/#5@ 12" #5@12_in @Toe #5@12" @Heel 1'-0" 1'-0" • • 8" _ .. -- 4'-0" 4'-1" 3'-T' 2" • 3" Z-4" 2'-4" ~ 3'-0" ~ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 7 - PL Page : 39 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 240_00psf 1651# Pp= 1955.56# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.33 0.75 0.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.98 OK Sliding =1.64 OK Total Bearing Load =1,303 lbs...resultant ecc.=6.78 in Soil Pressure @ Toe =1,072 psf OK Soil Pressure @ Heel =0 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,501 psf ACI Factored @ Heel =0 psf Footing Shear @ Toe =7.1 psi OK Footing Shear @ Heel =6.0 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =780.0 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 391.0 888.9 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.241 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =798.4lbsStrength Level Service Level Strength Level =886.2ft-# Service Level Strength Level =22.2psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 7 - SW Page : 40 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING ~------.. • ~I---------• ~------.. • '--.I---------• l~ ______ _.1 I ~-----.. •------------ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0735 in2/ft (4/3) * As :0.0979 in2/ft Min Stem T&S Reinf Area 0.588 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1296 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 1.75 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0016.00 1.00 ft Footing Thickness =in 2.75= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 1,501 7,773 900 573 7.11 75.00 Heel: 0 83 507 424 6.05 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.59 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 7 - SW Page : 41 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 306.0 1.25 382.5 Earth @ Stem Transitions =Footing Weight = 343.8 1.38 472.7 Key Weight = 133.3 1.33 177.8 Added Lateral Load lbs =1,082.5 Vert. Component Total = 1,303.4 2,138.6 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =780.0 O.T.M. = Resisting/Overturning Ratio =1.98 Vertical Loads used for Soil Pressure =1,303.4 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 520.3 2.13 2.13 1,105.7 1,105.7 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 780.0 1.39 1,082.5 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.044 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 7 - SW Page : 42 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 7 - SW Page : 43Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 6"w/#5@ 12" #5@ 12.in @Toe #5@12" @Heel • 1·-0· g• 4'-1" 3·-4· 2" 3• 1'-4" s· 1·-1· 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 7 - SW Page : 44 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section E-E ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Ppc 88889#L 't, o_ t- <') N t-o 780# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.60 0.50 0.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 240.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.59 OK Sliding =1.58 OK Total Bearing Load =2,166 lbs...resultant ecc.=4.97 in Soil Pressure @ Toe =878 psf OK Soil Pressure @ Heel =205 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,570 psf ACI Factored @ Heel =366 psf Footing Shear @ Toe =7.9 psi OK Footing Shear @ Heel =9.2 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,650.5 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 649.8 1,955.6 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.792 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,928.4lbsStrength Level Service Level Strength Level =2,911.3ft-# Service Level Strength Level =53.6psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 8 - PL Page : 45 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING I • I • n - ~ .1 ~ ~-------• '--.I ______ __.1 I~-------• I ~-----.. •----------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2413 in2/ft (4/3) * As :0.3217 in2/ft Min Stem T&S Reinf Area 0.590 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2413 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 3.00 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0028.00 1.00 ft Footing Thickness =in 4.00= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 1,570 8,817 900 660 7.94 75.00 Heel: 366 1,928 3,356 1,428 9.21 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.86 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 8 - PL Page : 46 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,698.12.22766.1=Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 307.5 1.25 384.4 Earth @ Stem Transitions =Footing Weight = 500.0 2.00 1,000.0 Key Weight = 233.3 1.33 311.1 Added Lateral Load lbs =3,005.2 Vert. Component Total = 2,165.8 4,789.2 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,650.5 O.T.M. = Resisting/Overturning Ratio =1.59 Vertical Loads used for Soil Pressure =2,165.8 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,125.0 2.75 2.75 3,093.8 3,093.8 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 884.5 1.48 1,307.0 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.025 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 8 - PL Page : 47 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 8 - PL Page : 48Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING G" w/#5@ 12" #5@12_in @Toe #5@12" @Heel 1'-0" 1'-0" • • 8" _ .. -- 4'-0" 4'-1" 3'-T' 2" • 3" Z-4" 2'-4" ~ 3'-0" ~ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 8 - PL Page : 49 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 240_00psf 1651# Pp= 1955.56# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 4.33 0.08 4.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.53 OK Sliding =1.51 OK Total Bearing Load =1,932 lbs...resultant ecc.=11.50 in Soil Pressure @ Toe =1,932 psf OK Soil Pressure @ Heel =0 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =2,705 psf ACI Factored @ Heel =0 psf Footing Shear @ Toe =13.2 psi OK Footing Shear @ Heel =14.3 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,411.6 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 579.6 1,555.6 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.530 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,349.9lbsStrength Level Service Level Strength Level =1,948.4ft-# Service Level Strength Level =37.5psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 8 - SL Page : 50 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING ~-------• '--.I---------• I~-------• I ~-----.. •------------ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1615 in2/ft (4/3) * As :0.2153 in2/ft Min Stem T&S Reinf Area 0.635 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1615 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 2.25 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0024.00 1.00 ft Footing Thickness =in 3.25= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 2,705 13,526 900 1,052 13.19 75.00 Heel: 0 28 1,291 1,263 14.31 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.70 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 8 - SL Page : 51 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 47.9 2.67 127.6 =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 330.8 1.25 413.4 Earth @ Stem Transitions =Footing Weight = 406.3 1.63 660.2 Key Weight = 200.0 1.33 266.7 Added Lateral Load lbs =2,429.6 Vert. Component Total = 1,932.0 3,717.4 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,411.6 O.T.M. = Resisting/Overturning Ratio =1.53 Vertical Loads used for Soil Pressure =1,932.0 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 947.2 2.38 2.38 2,249.6 2,249.6 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 1,411.6 1.72 2,635.4 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.073 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 8 - SL Page : 52 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 8 - SL Page : 53 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING 6"w/#5@12" #5@12.in @Toe #5@12" @Heel • • 1'-0" 8" 4 1" 4'-9" 4'-4" 4'-5" 2'-0" 1'-7" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 8 - SL Page : 54Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section F-F ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 1555.56# 't, Q_ <D N N (') 0) 4 1412# r ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.92 0.50 0.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 240.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.61 OK Sliding =1.58 OK Total Bearing Load =2,460 lbs...resultant ecc.=5.57 in Soil Pressure @ Toe =959 psf OK Soil Pressure @ Heel =199 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,702 psf ACI Factored @ Heel =354 psf Footing Shear @ Toe =8.7 psi OK Footing Shear @ Heel =10.1 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,838.1 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 738.1 2,172.2 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.971 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =2,190.2lbsStrength Level Service Level Strength Level =3,569.9ft-# Service Level Strength Level =60.8psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 9 - PL Page : 55 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING I i I i n ~ ~ ~l ~ ~-------• '--.I ______ __.1 I~-------• I ~-----.. •------------ 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2959 in2/ft (4/3) * As :0.3945 in2/ft Min Stem T&S Reinf Area 0.636 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2959 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 3.25 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0030.00 1.00 ft Footing Thickness =in 4.25= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 1,702 9,577 900 723 8.69 75.00 Heel: 354 2,437 4,243 1,805 10.15 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.92 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 9 - PL Page : 56 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel 1,952.12.38821.4=Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 331.5 1.25 414.4 Earth @ Stem Transitions =Footing Weight = 531.3 2.13 1,128.9 Key Weight = 250.0 1.33 333.3 Added Lateral Load lbs =3,563.1 Vert. Component Total = 2,460.3 5,750.7 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,838.1 O.T.M. = Resisting/Overturning Ratio =1.61 Vertical Loads used for Soil Pressure =2,460.3 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 1,347.5 2.88 2.88 3,874.1 3,874.1 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 1,016.7 1.58 1,611.0 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.028 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 9 - PL Page : 57 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 9 - PL Page : 58 Dsgnr:M. Farrington Date:4 MAR 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING G" w/#5@ 12" #5@12.in @Toe #5@12" @Heel • • 1'-0" 8" 1'-0"_ 4'-5" 3'-11" 2" 3" 2'-6" Z-7" 3'-3" 4'-3" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 9 - PL Page : 59Dsgnr:M. Farrington Date:4 MAR 2020Description....Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 2172-22# -"' Q_ lJ) "' CD "' Cf) 240_00psf IT] -"' Q_ N N Cf) Cf) 1838# ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad 3.92 0.50 0.00 0.00 2,500.0 90.0 0.0 400.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 125.00=pcf = Soil Density, Heel =Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe 125.00 pcf Footing||Soil Friction =0.300 Soil height to ignorefor passive pressure =6.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 0.0 Lateral Load =0.0 #/ft 0.0 0.0 0.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft NOT Used To Resist Sliding & Overturning NOT Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability RatiosOverturning =1.77 OK Sliding =1.65 OK Total Bearing Load =1,608 lbs...resultant ecc.=8.73 in Soil Pressure @ Toe =1,388 psf OK Soil Pressure @ Heel =0 psf OK Allowable =2,500 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =1,944 psf ACI Factored @ Heel =0 psf Footing Shear @ Toe =9.4 psi OK Footing Shear @ Heel =9.2 psi OK Allowable =75.0 psi Sliding Calcs Lateral Sliding Force =1,016.7 lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 482.5 1,200.0 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction Bottom Stem OK Shear.....Actual Design Height Above Ftg =0.00ft Wall Material Above "Ht"=Concrete Thickness =6.00Rebar Size =#5 Rebar Spacing =12.00 Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.393 Total Force @ Section =lbs Moment....Actual =ft-# Moment.....Allowable =3,674.7 =psi Shear.....Allowable =75.0psi Wall Weight =75.0psf Rebar Depth 'd'=3.00in Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Dataf'c =2,500.0psi Fy =60,000.0 Masonry Design Method ASD= Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi Service Level =1,106.4lbsStrength Level Service Level Strength Level =1,445.7ft-# Service Level Strength Level =30.7psi Design Method =LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing pressures. Anet (Masonry)=in2 Page : 1 Detail 9 - SL Page : 60 Dsgnr:M. Farrington Date:28 FEB 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGI N EERING I • I • n ~ ~~ ~ ~-------• '--.I ______ __.1 I~-------• I ~--------•----------- 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1198 in2/ft (4/3) * As :0.1598 in2/ft Min Stem T&S Reinf Area 0.636 in2 200bd/fy : 200(12)(3)/60000 :0.12 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft 0.0018bh : 0.0018(12)(6) :0.1296 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.12 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area :0.31 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area :0.4064 in2/ft #6@ 36.67 in #6@ 73.33 in 1.00 2.00 10.00 Footing Torsion, Tu ==ft-lbs0.00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 =2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key DepthKey Width =in=in = 8.0020.00 1.00 ft Footing Thickness =in 3.00= Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00 pcfFooting Concrete DensityFy =60,000 psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 #4@ 11.11 in, #5@ 17.22 in, #6@ 24.44 in, #7@ 33.33 in, #8@ 43.88 in, #9@ 5 =None Spec'd = = = = = 1,944 9,984 900 757 9.41 75.00 Heel: 0 76 830 754 9.19 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 5 @ 12.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.65 0.22 #4@ 11.11 in #5@ 17.22 in #6@ 24.44 in in2 in2 /ft If two layers of horizontal bars: #4@ 22.22 in #5@ 34.44 in #6@ 48.89 in supplemental design for footing torsion. Page : 2 Detail 9 - SL Page : 61 Dsgnr:M. Farrington Date:28 FEB 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING • 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft ft-#lbs Sloped Soil Over Heel =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = = = = Stem Weight(s) = 331.5 1.25 414.4 Earth @ Stem Transitions =Footing Weight = 375.0 1.50 562.5 Key Weight = 166.7 1.33 222.2 Added Lateral Load lbs =1,611.0 Vert. Component Total = 1,608.2 2,852.8 * Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =1,016.7 O.T.M. = Resisting/Overturning Ratio =1.77 Vertical Loads used for Soil Pressure =1,608.2 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) 735.0 2.25 2.25 1,653.8 1,653.8 Watre Table Buoyant Force = HL Act Pres (ab water tbl) HL Act Pres (be water tbl) 1,016.7 1.58 1,611.0 Hydrostatic Force Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.057 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page : 3 Detail 9 - SL Page : 62 Dsgnr:M. Farrington Date:28 FEB 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING I 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 4 Detail 9 - SL Page : 63 Dsgnr:M. Farrington Date:28 FEB 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING G"w/#5@ 12" #5@12.in @Toe #5@12" @Heel 1'-0" 1'-0" • 4'-5" 3'-11" • 3" 1'-8" 8" 1'-4" 23241 Arroyo Vista Rancho Santa Margarita, CA 92688 Title : This Wall in File: U:\2020\20-150-00 BMW Carlsbad_Structural Services\Structural\Retain-Pro - Enerca RetainPro (c) 1987-2019, Build 11.20.02.28 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16License : KW-06062010License To : GMU Geotechnical, Inc. Project Name/Number : bmw carlsbad Page : 5 Detail 9 - SL Page : 64 Dsgnr:M. Farrington Date:28 FEB 2020 Description.... Civil Section H-H ,. ......... 111 I I STRUCTURAL '-,ll""IU ENGINEERING Pp= 1200.00# -(/} 0. N (') 00 00 (') 1017# r ■ Hydrostatic Force ■ Lateral earth pressure due to the soil BELOW water table