Loading...
HomeMy WebLinkAboutDWG 440-5L; CT 02-17; FAIR OAKS VALLEY - SHELLEY PROPERTY; 01-32SHEET INDEX PACKAGE SHEET# 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 LANDS. SHEET# T1 10 11 12 13 14 15 16 17 18 19 110 111 112 113 114 LO L1 L2 L3 L4 LS L6 L7 L8 L9 L10 L11 L12 L13 L 14 L15 INSPECTION PROCEDURES: SHEET DESCRIPTION TITLE SHEET IRRIGATION SCHEDULES AND NOTES IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION PLAN IRRIGATION DETAILS IRRIGATION DETAILS IRRIGATION DETAILS AND SPECIFICATIONS IRRIGATION SPECIFICATIONS IRRIGATION SPECIFICATIONS PLANTING LEGEND PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING PLAN PLANTING DETAILS AND SPECIFICATIONS FENCING PLAN FENCING DIMENSION PLAN FENCING DIMENSION PLAN TRAIL PLAN MAINTENENCE PLAN INSPECTION OF ALL THE PROJECT SHALL BE PERFORMED BY THE LANDSCAPE ARCHITECT OF WORK, OR HIS DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLOWING COMPLETION OF THE WORK, THE LANDSCAPE ARCHITECT OF THE WORK WILL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "FINAL LANDSCAPE CERTIFICATION FORM." A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE. "FINAL L<\NDSCAPE CERTIFICATION FORM" FAX TO: 760-944-8943 LANDSCAPE INSPECTION REQUEST PHONE LINE: 760-602-4602 PRIOR TO THE START OF GRADING THE APPLICANT OR APPLICANT'S AGENT SHALL OBTAIN CITY APPROVAL OF A CONSTRUCTION SCHEDULE AND/ OR EXHIBIT OUTLINING THE TIMING OF THF SLOPE PLANTING AND IRRIGATION. THE SCHEDULE SHALL SHOW TIMING OF CONSTRUCTION OF FREE STANDING, RETAINING AND CRIB WALLS IMMEDIATELY AFTER ROUGH GRADING AS EACH LOCATION IS ACHIEVED. IRRIGATION AND PLANTING SHALL TAKE PLACE AS GRADING PROGRESSES. INSTALLATION OF IRRIGATION AS SHOWN ON THE APPROVED PL<\NS SHALL COMMENCE WITHIN 10 DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. PLANTING AND IRRIGATION FOR THE SLOPE AREAS SHALL BE COMPLETELY INSTALLED, AS SHOWN ON THE APPROVED PLANS, WITHIN 30 DAYS AFTER THE IRRIGATION INSTALLATION FIRST COMMENCES. f:. NORTH ....... l .... LOT 13 OPEN SPACE I I \ I I \ I I KEYMAP NORTH N.T.S. \ I I \ I I \ \ \ I I \ I I \ \ I ___ _j I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH OLIVENHAIN WATER DISTRICT OMWD VICINITY MAP NTS I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD, DEPARTMENT OF ENVIRONMENTAL HEALTH, AND 0MWD IS CONFINED TO REVIEW APPROVED BY: (£---7?-!J ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. COST AV LEUCADIA \ BLVD f SITE RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: (858) 755-3188 BY: _________ DATE: ___ _ RALPH STONE R.L.A. N0.:__,_14"-'5"'9 __________ _ REGISTRATION EXPIRATION DATE: ~os,.,_/~is~ __ _ DATE DA TE: OCT. 7, 2013 Af'P!<OVED F0!O. PI.-AATINS AND l.'.'f<Fi16ATI0N Of!b Y, INCI.UDIN5 P=!SE OGATION OF n.J-\NTINS AREA -1 "AS BUILT" RCE __ _ EXP. ___ _ DATE REVIEWED BY: INSPECTOR DATE r---t----+-1'1-l~_"'~ __ '_""'_"_-r,_., _1> _,.s._u<,;_""_.;._,. ---+----+--t---t---1 ._I S=H=E1E=T :'..:I =C=I=T=Y==O=F===C=A=R=L=S=B=A=D=="l'==i=I ~ PLANNING DEPARTMENT !----t--,----------------+---f--+---f---l TITLE PAGE 1-----t---+---------+-----+-+----+---1 CT 02-17 SHELLEY PRO PER TY "FAIR OAKS V ALL,EY" I APPROVED J-t,,][ 4:-f::::.fl,At ~====!====~~============================1====~====1====~===~ P:-c-L-A-NN .... N .... 'IN .... G--'-"'-"--'-+~'-'"-'-""""'+---1 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DWN BY: __ _ '--DA_TE_LI_NI_TIA_L--j __ DA_TE_i__::_clNl __ ·nA __ L---1 CHKD BY: __ _ OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. CT 02-17 I DRAWING NO. 440-51 IRRIGATION SCHEDULE IRRIGATION HEADS SCHEDULE IRRIGATION NOTES llvt,l!IOL "EB IZI ------- -··- RAINE>IRD l00-FE6 RAINE>IRD EASY RAIN E>UCKNER Gle«NPATARl<tl FROVDE MR:;. NIE>CO OR EQUAL FESCO 1IS CL 3IS -PURPLE 6C!4 42> eE • PLIRPLE OEl!CRlPTI(lll DETAIL NU~EA PRESSURE REOOLATOR 4 ON 5HT .12 E:LECTRIC CONTROL VAi.YE: !SIZE PER FLAN) E:LECTRIC CONTROL VALVE 14 ON 5f-/T .1.3 WI EASY RAIN e>AT. CONTROLLER I" ACME THREAD QUICK 6 ON 5HT 12 COUPLING NON-POTAE:>L!a VALVE: e>-ZE a.ATE VAi.VE: !l'-2•,"i 3 ON Sf-IT 12 ATM05PI-JERiC VACUUM 13REAKER IS ON SHT 13 U6!a SCH. 40•1-ln" 01" LESS, USE CLASS :;re, PURPLE LINE: IF 2' OR GREATER. 1-114' T'rPiCAL ALL HOMEOWNER LOW II ON &HT 13 II ON SHT 13 Nbma Sl=T OJTLET PRE&SllRE TO PROVIDE FF<ESSURE INDICATED IN SCMEDULE AT HEAD HAS FURFLE RUeBER COVER MOUNT 6' ABOVE Hial-lEST HEAD IN 5Y5TEM SERVED SYMBOL • IMNUFflPTl,IREA RAINelRD RAINelRD RAINelRD NOTE6' 1&12-SAM-S SERies WI 100 .. -NP COVER S' QTR, HLF, RJLL NOZZLE 1&12-SAM-8 Sl=RIES UII 1000-NP COVER 8' OTR, MLF, RJLL. NOZZLE 1&12-SAM-i., lll!RIES W/ l!!<U>-NF COVER 10' OTR. HLF, FULL NOZZI-E !Sl2-5AM-!2 5El"IE5 WI IS<t10-NP COVEi" 12' 011'?. 1-lLI", FULL >IOZZI..E 1812-SAM-IS SERIES WI IU0-NI" COVEll;t re,• QTR, MLF, RJLL NOZZLE 1211 PUI-FLI: FOP-UP SF-MY HEAD , ore on /SEE NOTE .,_ FOR NOZZLE/ SHT. 12 12" PURPLE POF-UF SPRAY HEAD 1 or 8 on !&!aE NOT,= "6 FOR NOZZLE/ 5HT. 12 12" PURPLE FOF-UF SPRAY HEAD 1 or 8 °" /SEE NOTE "6 FOR NOZZLE! 5HT. 12 12" PURPLE FOP-UP SPRAY HEAD !SEE NOTE "6 FOR NOZZI..EJ 1or&on SHT.12 eueet.ER ON RISE!'< 2" Aeove a.RADE 8 °" 8HT. 12 OPERA TINl'I PRESBURE 30 !),I) FLOW IN BPM QTF\ HLF, Fl.,l.l. 10' 12' 15' I. ALL BA&E INFOf<MATION HAS BEEN TAKEN FROM DRAWINGS PROVIDED BY Tl-'E PASCO ENC.INEERING THF<OUGH RALPH 5TONf; AND A550CIATES. 2. REFER TO PROJECT SFECl!'ICATION5 FOR INS:ALLATION AND MATERlAL REQUIREMENTS AND ME:THODOLOOY, 3, CONTRACTOR SHALL FIELD VERIFY FRESSJRE AT FOINT-OF-CO'-INECTION LOCATIONS FOi'< EACH TAP FRIOR TO ORDE!'<ING MATERIALS OR 5TA~TING ANY IRR14ATION INSTALLATION AND NOTIFY CONSULTANT Cl' ANY PIFFERENCE OF 10 F&I AT THE POINT OF CONNECT!ON. 4. 6YSTEM HAS eEEN DESIGNiSD BA6ieD ON Tl-lE STATIC WATSI" FF<E5SURE FROM 5TATEP FRE55URE. lF CONTRACTOR FAILS TO NOTIFY CONSULT ANT H!a ASSUMES FIJLL RE5PON51!:31LITY FOR ANY SY&TEM ALTERATIONS AS . DIF<ECTED BY TME CONSULTANT. F.O.C. 1"81 32 1&.8 c.FM MAX DEMAND TOTAL LAND- SCAPED AREA, 5. INSTALL AAINelRD SERIES PLASTIC NOZZLES ON ALL FLll"FLE: C\J APPROVED PAIGE APPROVED P-1111-D &CH-40!:'E (el! , e>ELL END/ COMMUNICATICN CAE:>LE PVC Fi.lRPLE LATERAL LINE !SIZE FER PLAN) HOMEou.NER 5YSTEM6(5EI= NOT!= '8/ FOF-UF SPRAY SPl'UNKLERS AS SPECIFIED SHALL e.l= USEP IN ALL RIGHT•OF-UJAY5 AND WITl-llN 1"'' OF ANY HARDSCAFE, TUI'!' OR OTHER AREA Wf-lER!a FEDESTl"IAN TRAfflC MAY OCCUR !'<ISER MOUNTED SPRAY &P,..INKLE!'<S MAY eE USl=D A5 DESCl"leED eELc<JJ, COVER SFRA Y HEADS FE:R THE SCHEPULE AND AS BASED ON T><E FOLLOWING SCHEDULE, APPROVED SCH -40 eE • PURPU• (el! • E>ELL END) PVC Fi.lRPLI= LATERAL LIN!= !SIZE FER FLAN) HOA 5Y5Tl=MS (5El= NOTE '8) Wl4ERE F'IFING 15 LOCATED IN THE CENTER OF SLOPES, SLOPE SPRAY 5ffilNKLER <>YelTEM5 USE 12' SCH 5<tl F<ieERe IJ)ITH RAINal!<D FA-85-NP 5HR.Je ADAPTER (51-Jl<Ue MODEL) IN LIEU OF TME FOF-UF eoolES SPECIFIED Aeove. REFER TO DETAIL. "3. DISTANCE Cl' HEAD SPACING &' AND LESS NOZZLE 6' SHORT AADIUS 6El"IEe 5' Sel"IES b-l!R1 APPROVED APPROVED FER 0MUJD STD. DETAIL SCH 8'l> 13E SCH 006E PVC IRRla.ATION SLEEVE: (&!al= NOT!, "1) PVC & TREET 5CH 00 SLEEVE !COORDINATED ON CIVIL DRAWING8) ( AL&O &EE eizes ON !AA. FLAN eHEETS> REDUCED BACK FLOW PREVENTER I ON 61-lT 12 SLEEVES SHALL EXTEND 12" BEYOND EDGI! OF PAV!Nc; 5LEEVE8 SHALL EXTEND 12" el=YOND EDGI= OF PAV!Na. RAIN61RD RAIN61RD lSlSI @ ® 0 6UFERIOR 2"·SIS-4$A-A:.-NC-T-HP l'M-2 FRESUR!a R!aa.ULATOR MASTER VALVE: 2 ON 5HT 12 !Rl=Fl=R TO FLAN) RAIN6IRD RAIN6IRD CALSENlll! CALSEN&!a not ahown HUNTER El 2000"' -X-M-FL- --&&..-Re MINI-CLIK·&a.·MC PRO-C WI REQUIRED QTY. MODULES Fl.OW Sl=NSOR <REFER TO FLAN) PEDESTAL CONTROLLER RAIN SENSOR IN ENCLOSUF<E INTERIOR lliAI.L MOUNT CONTROLLER !IN5TAI.LED AFTER MOMES ARE E>UILT) ONE PEI" LOT 2 ON 6HT 12 11 ON 5HT 14 COORDINATE FOWER AND CONTROL CONDUIT WI e>JILDER. RAiNelRD RAIN6IRD RAINelRP WATERTRONICS WATER METER &EE DETAIL CL TE:>V-IS-460-3-SS-IIS BOOSTER Ft.IMP &TATION 21 ON 6HT, 14 E:>Y OTHERS SEE DETAIL /REFER TO FLAN FOR S!Zi=J REC'l'CLED WATER 5la.NAGE !61aE FLA'i5 FOR LOCATIONS) 10 ON 8HT.14 RAINelRD rl-1 cf RAINell"D FIELD 5ATELLITE UNIT • STATION NO] a.ALLON6 FER MINUTE PLANT TYf'I!! HOA VALVES ~Gr;J3 ~HJi -J-J ~J~ RAINelRD RAINelRD RAINell"D RAINelRD RAINelRD ELECTRIC CONTROL VAL ve elze GAi.LONS PER MINUTE LOT NO. AND eATTERr OPERATED] CONTROLLER NO. PLANT TYPE HOMEOWNER ii/ILi/ES ELECTRIC CONTROL VALvE SIZE 6ACKFLOUJ iNSTALLATION AND TE5TING REQUIREMENT5, ALL IRRIGATION !3ACi<f=LOW FREvENTERS SHALL !3E TESTED !3Y A CERTIFIED TESTER AND THE RESUL re c;,lveN THE oUvENHAIN MUNICIPAL WATER DISTRICT_ FIFE !3ETWEEN METER AND 8ACKFLOW FREvENTER SHALL eE "SCHEDULE K HARD =FFER". AFFROYED CONTRACT !3ACKFLOW TESTERS CAN !3E FOUND ON THE CITY WE!3 SITE AT www.c1.carl•bad.ca1.1•lpdfdoc.hLml?pld+340 DR CALL 760.438,2722, M J-d- I-IUNTER ON HUNTEI" ALL NOTIFICATIONS FOR 8ACKFLOW INSTALLATION INSPECTIONS AND TESTING, 5HALL NOTIFY OLlvENHAIN MUNICIPAL WATER DISTRICT. !3ACKLFOW INSTALLATION SHALL 6E FER THE OMUJD STD. DRAWING C-2.1 AND Tl-IE SPECIFICATION& REFERENCED THEREON. HUNTER ON I-IUNTER INSTALLATION TlMING REQUIREMENTS, WATER SERVICE (POINT-OF-CONNECTION) INSTALLATION, TEMPORARY OR FERMENANT, SHALL !3E IN PLACE TO COINCIDE WITH PLANTING TIMING 5FECIFIED IN E-'>-L IJ HUNTER ON HUNTER HOA MAINLINE UJITHIN RO.llJ. CONTROL 5Y5TEM PARAMETERS -HOA AREAS, HUNTER ON I-IUNTER CONTRACTOR SHALL SECURE AN ENCROACI-IMENT PERMIT FROM Tl-IE CITY OF CARLS!3AD ENGINEERING DEPARTMENT FOR INSTALLATION OF THE IRRIC,,ATION MAINLINE WITHIN Tl-lE RIC,,1-lT -OF-WAY. CONiRACfOR SI-IALL RECElvE TRAINING, FROM CALSENSE IN THE CONTROL SYSTEM St:::TUF AND OFt:::RATION. THE CONTROL SYSTEM Sl-lALL !3E SET-UP TO RUN '13'!' CAPACITY' AT A COM!3INED FLOW RATE (!3Tu.N =NTROLLERS) OF erZJ c;,FM, CONTACT DAVID MEEHAN AT 76fZJ.o8fZJJ829 HUNTER ON HUNTER HUNTER ON HUNTER RECYCLED WATER NOTES I. A1.L WORK eHALL l3E DONE IN ACCQRPANCE WIT14 THE OLIVENMAIN MUNlclf'I..E UJATER Di&Tl"ICT'S RULE& AND REGULATION&. 2. Dl"INKINa. FO!JNTAIN5 AND DESIGNATED OUTDOO!O EATINa. AREAS eHALL 6E PF<OTECTED AGAINST CONTACT WITH RECYCLED WATER SPRAY, MIST 01'< l'<IJNOF!', 3. eE&T MA"<AGEMENT PRACTICES SHAI.L eE USED TO l=LIMINATE OR CONTl'<OL TO THE eE&T EXTENT POS51!:3LE, R!JN-OF!', OVE!<oF!<AY AND MISTIN!l. 4. HO$ e,les Al'<!! &Tl"ICTL Y PROHlelTED. &. CF<OSS-CONNECTIONS eET!LEEN REC'l'CLED lliArEF< LINES AND FOTAEILE IJ)ATER LINE& ARE 5TRICTL Y FROHlel'IEO. 6. NO SUi;&TITUTION OF PIFE MATE!'<IAL5 WILL l3E ALLOWED WITMOUT PF<IOR APPROVAL OF THE OLIVENHAIN MUNICIPLE WATER DIST!'<ICT, 1. ALL MAIN LINE FIFE& SHALL HAVE UlAl<NINil TAPE FER OLIVENHEIN MUNICIFLE UJATER Dl&n,,lcT Rill.EB AND F<EOOLATIONS. &. HOUF<S FOR l!s'<ic;ATiON WITl-l l'<ECYCLED WATl=F< ARE FROM "'"""""· AND "'"'"•-"'· TME MOURe FOR l!s'<IGATION WITH Dl&lt,FECTED TERTIARY REC'l'CLED WATER MAY eE MODIF!ED E>Y THE LOCAL -"JJTMORiTr. lls'<lc;ATION DUl'<ING PUE>LIC USE FEl'<IOD5 IJ)JTH Di51Nl'ECT5D TlaRTlARY RECYCLED WATER SMALL eE UNDER TM!= 5UFERVISION OF TME DE&IC.INATED U6ER 5UFERVISIOR. lls'<ia.ATION WITH WATEI" OF LEOOE!t O>JALIT'r THAN Dl&IN!'ECTED TEF<TIAl'<Y RECYCLED WATEI'< SHALL eE el'TWEEN THE HOU"'5 OF ~''°'°P"'-AND & .. ~a.m.. a eLil"IAL OF ALL WIF<INa. AND FIFINco 6f-lAI.L MEET THE OLIVENMAIN MUNICIFAL WATER Dl5TF<ICT5 fa.lLE5 AND REOOLATIONa 10, NON-DESIGNATED use AREAS 5HALL eE FF<OTECTED FROM CONTACT UJITH l"ECYCLED UlATEI", IJ)HETHEI" e,y WINDeLOILN SF!sAY OR 6Y Dil<ECT APPLICATION THROUi:;H ll'<Rlcr.ATION OR OT>!!,R U5E, LACK OF PROTECTION, l.l-<ETHER 6Y DESIGN, CON!ITl"UCTION Fl"ACTICE5 Of" 5Y&TeM OFE~TION IS &Ti><ICTLY FROHle>ITED. II. lls'<lc;ATION HEADS SHALL eE RELOCATED OR ADJUSTED TO MINIMIZI= Of" i=LIMINATE OVEl"SFRAYINa. ON SIDEWALK&, STl"EET& AND NON·DE&kiNATED uSE AREAS. 12. RECYCLED UlATER alllCK COUPLING VALVES 5f-lALL eE OF A TYFE DESIGNED FOi" USE ON RECYCLED uJATER DISTl"leLITION 6YSTeM& FER OLIVENMAIN MUNICIPAL WATER DISTRICTS l'IJLE& A"ID REa.tlLATIONa 13. ON RECYCLED 6YSTeMS, ALL AFFURENTANCES <GFRINl<LER MEADS, VALVE OOXES, ETCJ SHALL eE COLOR CODED PU!<PLE FER AUil/A OOID!aLINE& AND SECTloJN 11&1>15 OF THE CALIFORNIA HEAL TH AND SAFETY CODE. 14. ALL l"""lc;ATION FIFES &HAI.L eE &TENCILED WIT>! THE lliAl"NINa. "NON-POTAEILE lliATER" OR 'RECYCLED WATER", COLOR CODED !PURPLE/ AND LAID IJ)ITH WAl"NIN(S TAPE llilTM &TENCILINa. ORIENTED TOWARD Tl-lE TOF OF THE TRENCf-1 FER OLIVEHAIN ML).!lclFAL WATER Dl5Tl"ICT'5 RULES AND l'<EGULATIONa I&. ON NEUl ON-SITE 5Y$TEM5 (FO;,T METER/, FOTAeLE WATEI", CONSTANT FRE65Uf<E RECYCLED WATER AND $ELJJE1'! LINE& SHOULD ee FLAC!eP A MINIMUM OF FOUi" FEET APART OR AS DIRECT!eP eY TME PROJECT i=Nc;INEER AND/OR REOOLATORY AGENCY. MEA5JREMl=NT5 SHALL eE eETUJEEN fACNC, SUR'ACE&, NOT FIFE Cl=NTERLINES, 16. CON5TANT f'RE56URI< f<ECYCLED WATER LINE& SHALL. CROSS AT LEAST TIJ)ELVE INCME5 eELOIJ) FOTAEILE WATER LINES AND MAINTAIN AT LEAST TIUELVE INC>!!,5 C"'°551Na. Sl=FEF<ATION eETu.EEN OTI4ER UTILITIES. 11. If A CONSTANT PRESSURE RECTCLED UJATER LINE MUST .el: INsTALLED AeOVE A FOTAeLE WATER LINE OF LE5S Tl-lAN TWELVE INCHES eELOW A FOTAEILE WATER LINE, THl=N Tf-1!, REC'l'CLED WATER LINE 5HALl. eE INSTALLED WITl-llN AN APPROVED PROTECTIVE SLEEVE FER THE OLIVEN>IAIN MUNICIFAL WATER Dl&Tl"ICT& FIULE5 AND REGULATIONS. !S. DEVE:LOFl=RICONTRACTOR SMAI.L CONDIJCT A CRO&&-CONNECTION TEST AND COVERAGE TE&T AS DIRECTED eY THE OLIVENHEIN J-fc!NICIPLE WATER Dien,,lcT AND THE SAN DIEGO CO\INT-r DEPAl"TMENT OF ENVIRONMENTAi. MEAi.TM FRloF< TO ANT USE OF l'<ECYCLED WATER l'a. Tf-/E REGLIIRED CF<Ol)S-CO>l'll=CTION IN5PECTION of-/ALL ISi= DONE EITHER eY THE OLIVENHAIN MUNICIFLE WATISR Dlen,,lcT AND/OF< TME &AN DIE® COUNT'r DEFAl"TMENT OF ENV:!OONMENTAL !4EALTl4. COFIE& OF h-laFECTION REPORTS WILL eE FORUJARDED TO TI;E NON-INSPECT!Nco PARTY. 2~. Tf..15 Dl:$k:iN AND LOCATION$ PROP05ED FOi' ~CYCI..EP WATEFe 11PO NOi D'"'!NK1' SiGiN.& 5HA1.J... e-1: CALLED OUT ON THE FLAN5. 2L u.!4EN RECYCLED \!/ATER eECOME5 AVAILAeL.E, AN ON sire USERIS'JFERVISIOR SHALL ISi= DE&la.NATED IN WRITIN!l. THIS INDIVIDUAL SHALL ee FAl"'ILIA" WITH F'I-UMelNil er&TEMS UJITHIN THIS f'ROFERTY, WITH TME eA5lc CONCEF'T5 OF eAOO'LOW/CROOO CONNECTION PROTECTION, Tl-IE RECYCLED FURVET0"'8 l<IJLE& AND REOOLATION5 AND THE SFEciFIC REQUIREMENTS OF A l'<ECYCLED WATER SYSTEM. COPiE& OF n;e DESla.NATION, WITH CONTACT PHONE NtlMeEF'<e SMALL ee PROVIDED TO TME OLIVEh'HAIN MJNIC!Pi.E WATEI'! DISTRICT AND OR THE SAN DIEGO CO.JNTY DEPARTMENT OF ENVIRONMENTAi. HEALTl4. EME"""l:NCY CONTACT, _c,Jarn=~="--------- OR AfT'E1I< MOURe CONTACT AT, 22. ALL RJeLIC AND PRIVATE POTABLE WATER MAINS, INCLUDINa. FiRE MAINa AD ANY WATER IJ)ELL& AND WATER COURSf,:& WITHIN Tl-iE RECYCLED WATER PROJECT 5HALL eE SHOWN ON THE FLANS. 23. CALL OUT ON TME FLANS IF THERE ARE OR Al"!= NOT DRINKINa. FOUNT A!Ne AND/OF< DE&IGNA TED OUTDOO!O EAT!Nco Al'<l!A6 ON THIS &ire, 24. EDUCA re ALL MAINTENANCE PERSONNEL ON A CONTINlJOUS eASi5 ON THE FRESENCE OF RECYCLED WATER. FER.SONNE~ MUST ISi= INFO;;MED THAT l'<ECYCLED WATER le MEANT FOR IRRicr.ATION PUF<FOSE& ONLY, AND la NOT FOi" Dl"lt<K!Na. PURPOSE&, HAND WASHiNa., CLEANINa. OF TOOLS, ETC. GIVEN THE Hla.H TUIENOVER ~TE OF EMPLOYEE& IN TrlE LAND&c:AFE INDUSTRY IT le iMFoRTANT THIS INFOl"MATION ee DE&Sl=MINATISD ON AN ALMOST DAILY eASl5. 2&. A FHYSICAL 6EFERATION SMALL eE PROVIDED 6ETu.EEN ADJACENT Ai'<EAS l!'<RkiATED WITH REC'l'CLED UJATER AND POTAE!l..E WATER 6EFE~TION Sf-lALL ee PROVIDED eY DISTANCE, CONCRETE MOW &Tl"IFS OR OTHER APPROVED MET=S. 3=<:!>.,•S-·FC-NP•"'-1& NOZ. 3=<:!>"·FC·5AM-NP-0.1S NOZ.. 3&0.,·S--FC-NP-0.1& NOZ. 3=<:!><tl-FC-SAM·Nf"-<tl.1& NOZ.. Gl!AR DRIVEN ROTOR POP-UP GEAR DRIVEN ROTOR GEAI" Dl"iVEN ROTOR POP-UP c;EAR Dl'<!VEN ROTOR Ue><tl-LS·PL·f;C-&AM·NF-&0"'<tl-MPR-2S NCZ =<:!>12-F -FC-5AM-NP•5=•MPR-2S NOZ GEAI" Dl"IVEN ROTOR FOF-LJF GEAR DRiVEN ROTOR =<:!>00-5-FL-FC-SAM-Ni"'-!l.,0<tl-MPR-25 NOZ 5<Z>l2-FL-FC-6AM·NP•6.,00-MPR-2S NOZ GEAR DRIVEN ROTOR POF-UF GEAR DRIVE:N ROTOR S"'OO·S-FL-FC-SAM-NF-&.,.,;:,.MPR-.oli> NOZ &iZ>l2 ·FL ·FC·5AM-NP-5<tle><tl·MPR•.o<tl NO:Z: ~~U~~ ~Fi!~N ROTOR 6"'0<t/•5-FL-FC-6AM-NP•500li>-MF1'0·:W NOZ &,z,12-PL-FC-5AM-NF-6000·MF1'0-30 NO% GEAR DRIVEN ROTOR POP-Uf' G!!AR DRIVEN ROTOR &iZ>e><tl-5-FL·FC·SAM-NP-&000-MPR-3!; NOZ &012·FL·FC-5AM-NP-UOO-MFR-3$ NOZ c;EAI" DRIVE'< ROTOR POP-UP Gl!AR PRIVEN ROTOR =<:!>0<tl-5·FL·FC-5AM-Ni"'-&li>00-MF1'0-35 NOZ =<:!>12-PL·FC-6AM-NP-&li>-""'·MF1'0-3& NOZ GEAR DRIVEN ROTOR POP-UP GEAR DRIVEN l"OTOR !;0N-5•FL·FC-6AM-NP·2.<!> &TD. NOZ 5'1>12·PL·FC·SAM-NF·2.<!> 5TD. NOZ 5'1>"0·5-FL-FC-5AM-NP-2.<!> &TD. NOZ =<:!>l2-PL-FC-5AM-NP-2.<!> STD. NOZ &0N-S-FL-FC-5AM-NP-3.<!> STD. NOZ &012-PL-FC·SAM-NP-3.<Z> STD. NOZ S000·5•FL·FC-5AM-NP-3.<!> STD. NOZ &012-FL·FC·SAM-NP-3.<Z> STD. NOZ .,.,,,,,,,.5.pe.Nf"-0.1!; NOZ. 5012-FL-FC-5AM-NF-S0""·MFR-25 NOZ 5012-FL-FC-5AM-NP-U<t/0-Mf'R·3S NO% S012•F'l-•FC•SAM•NF•2.<!> STD. NOZ S012·FL·FC•5AM-NP-3.<Z> STD. NOZ MFIOO<tl ~<t/"-2l<tl" NOZ. PR06-00-FR5!l0·CV·i'< MF!"""' 36<tl" NOZ. PR06·0<tl-FR53;:,-cv-1'! MF2"""<tl ~0• -210" NOZ. FROS·"li>·FF<S-40-CY·R l1F2,U,<t/ 360" NOZ. FROS-00-Ff<S.40-CV•R PR06·00·FR640-CY-R FROS-0li>-F'R64li>-CV-PI: NOTES. GEAR DRIVE'I ROTOR POP-UP GEAR PR!VEN ROTOR c;EA." DRIVEN ROTOR POF-UF GEAR PRIVEN ROTOR GEAR DRIVEN l'<OTOR FOP-UP GEAR Dl"IVEN ROTOR a.EAR DRIVEN ROTOR FOP-UP GEAR DRIVEN ROTOR GEAI" DRIVE:N ROTOR GEAR DRIVE:N ROTOR GEAR DRIVEN ROTOR a.EAR DRIVEN ROTOR GEAR DRIVE:N ROTOR MF ROTATOR NOZZLES ON PRES. REG. SHRUB eoDY MF' ROTATOR NOZZLES ON PRES. l"EG. SHRUe 130DY MF' ROTATOR NOZZLES ON FRE5. REG. &HRUe 130DY MF ROTATOR NOZZLee ON PRES. F!EG. SHRUB eoDY MP ROTATOR NOZZLl!,5 ON FRES. REG. SHRUe eoDY MF ROTATOR NOZZLES ON PRES. l'<EG. 5HRUJ9 eoDY 14 CN SMT.12 10 ON SHT.12 14 ON 5HT.12 10 ON SHL 12 14 ON SHT.12 10 ON SHT.12 14 ON SHT.12 Iii> ON SHT. 12 14 CN 5HT. 12 I" ON SHT. 12 14 ON SHT. 12 10 ON &HT. 12 14 ON 51-JT. 12 l<ti ON SHT. 12 14 ON SHT. 12 Iii> ON SHT. 12 14 ON SHT. 12 10 ON 5!-IT. 12 14 ON SHT.12 I" ON SHT. 12 14 ON SI-IT. 12 !<ti ON SHT. 12 14 ON SHT. 12 10 ON 8HT.12 14 ON &HT. 12 Iii> ON 5HT. 12 Iii> ON 51-lT. 12 10 ON 5HT.12 l<ti ON &HT. 12 l<tl ON 5HT. 12 e ON 5HT. 12 e ON 5HT. 12 e ON SHT. 12 6 ON 5HT. 12 e ON 5HT. 12 5 ON BHT. 12 4"' 4"' 4"' 4,z, 4"' 4<tl 40 40 40 40 40 0.11 0.11 1.61, 3.33 11>1 2.11, 2.11 2.11 0.11 2.11, 2.11 0.15 <t>A2, 0.14 11' 11' 2&' 30' 3&' 11' 3&' 38' 13'-21' MiD 5LOFE CONDITIONS BOTTOM OF SLOPES MID 5LOFe CO'-IDITIONS !:30TTOM OF SLOPES MID SLOPE CO>IDITIONS BOTTOM OF 5LOFE5 MID SLOPE CO'-IDITION5 130TTOM OF 5LOFE5 MiD SLOPE CO'IDITIONS eoTTOM OF 5LOFE5 MID SLOPE CO'IPITION5 ElOTTOM OF 5LOPE8 MID SLOFE CO'.'iDITIONS BOTTOM OF 5LOPE5 MID SLOP!= CO>!DITIONS eDTTOM OF SLOPES MiD SLOPE CONDITION& eDTTOM OF SLCFl:5 MiD SLOFE C0'1DITIONS eoTTOM OF SLOPES MiD SLOFE CCNDITION5 BOTTOM OF SLOPES M'D SLOPE CONDITIONS eorroM OF SLOFE5 TOF OF SLOPE COND iTIONS TOF OF 5LOFE CONDITIONS TOP OF SLOPE CONDITIONS TOP OF 5LOFE CONDITIONS TOP OF SLOFE CONDITIONS TOF OF SLOFE CONDITIONS per apaelt'lg 22'~3-'Z)' psr &paeTl'l9 POP-UP ROTOR /JffilNKLERS AS 5FECIFIED SHALL BE USED IN AI.L RIGHT·OF-UIAr5 ANP WITHIN 10' OF ANY HARD5CAPE, TUI'!' OR OTHER AREA UJ\.IERE PEDESTRIAN TRAFFIC MAY OCCUR. 1'<16ER MOUNTED ROTOR &F'RINKLEF'<e MAr eE USED AS DESCRl6ED Bf=LOW, WHERE FIFING 15 LOCATED IN ™" CENTER OF SLOPES 01" IN CONDITIONS NOT EXFO&ED TO FEDeSTl"l<;:AN TRAFFIC !AS DEF]NED Aeove) SLOPE ROTOR 5FRNl<Lf;R ereTEM5 USE 12" 5cH 00 RISJ=F<S WITH eHRUe MOD!L IN LIEU OF TME FOP-Uf' eoDIES 6FECIFIED Al50VE. REFER TO DETAIL ~6. RECLAIMED WATER SIGNAGE 6' TO 7' e,• TO~' ~• 5ERl!<5 1"'' TO II' !2' SER!E5 12 1 ro 1e-• re,• SERIES 6. CONTRACTOR TO FIELD VE:RIFY SIZE. LOCATION AND QUANTITY Cl' EXiSTING STF<EET SLEEVE:& INST ALLl=D UNDER &Tl"EET IMl"ROVEMENT PACKAGE PRIOR TO INSTALLATION OF IRRla.ATION 5Y&TEl1 , ANP NOTIFY CONSUL TA'iT OF ANY D IPFERENCES. 1. INSTALL IRRIGATION SLEEVES U,,,PER ALL 51DEU/ALK5 FER THE FOLLOll!INC. SCHEDULE, PIPE S!Ze QR llilRE OUANTITr REQUIRED SLEl:VE!Si l-2;:, CONTROL WiR!aS 21--40 CONTROL WIREe 1~211 &DR Z.P FVC 2·2' SDR 3!1 PVC ALL OTHEI" SL.EEY!, SIZI= 51-lALL el: 2x LAl'<l:llE~ Tl-lAN EXTEND 5LEl=,vlNG 12" el:YOND E:Dc.E OF ADJcENT PAvlNc. RiaG>JIR!aD 5Ll=Ev1Na. DEFTl-l5, DESCRIPTION OF SLEEVE, SLEEVE:& JNDER ROADS, DEl"TH, 6' OP!: LE55 IN PIAMETISR, 36" COVER c.REATER THAN 6" IN DIA'"1ETER, 4&" COVER SLEEVES .JNDEI" FAYING /NON-ROADS/ LES& '."HAN 3' IN DIAMETER IB" COVER 311 -Er,;1'11 IN DIAMETER 2411 COVER 6' OR a.REATER IN DIAMETER 56" COVEi'!: MATERIAl, SCH 5<tl PVC SCH 00 PVC SCH 4"' FVC SCl-l -40 PVC SCl-l 4€> PVC FOi'< EXISTING 5TRE:ET SLEEVING R!aFER TO CIVIL IMPROVEMENT PLANS FOR SIZES AND IRRla.A TION FLAN SHEETS. 5. LATERAL FIPINa. SHALL 6E INSTALLED 6ELOW a.RADE USING &CH 4<t> eELL END FIFE. 'a. Wl-lERE LOW HEAD DRAINAa.E le OCCUl"ING AFTER INSTALLATION OF 5Y6TEM, INSTALL LINE SIZE C,1ECK VALVES AS NECESSARY, AT INTERVALS OF EIGHT VERTICAL FEET Aeove AND UPSTREAM OF DRAININa. HEAD, >IOTS ALL HE:AP ASSEMaLIES ARE 5HOllJN TO eE EOUJPFEP W!TH INTEGRAL OR Rl5ER MOUNTED CMECK VALVE:&. NO DRINKING, FOUNTAINS OR DESIGNATED OUTDOOR EATING AREAS ARE FROFOSED AS A FART OF Tl-llS PROJECT, VAL YES AND PRESSURE S~Ff'L Y LINE 51-lOU.N IN SIDEWALK OR FAYING FOR CLARITY ONLY. VALVES AND PRESSURE SUPPLY LINE TO 6E INSTALLED le" !3ACK OF CURI:! OR SIDEWALK OUTSIDE Tl-lE Cl TY R.O.W. Aqua Commercial Irrigation 810 Lo~ Va1Iacitoo s:vd,, Suite 204 San \ilar;os, Carlfomla ll.2069 Ph: (760)750-1900 Fax: (760)75JJ.1999 OC1 ltrlt"IIO!I c);1~i11r,, Plarm1% Bi li1'<1:ter Ma,·,agemt,ant RALPH STONE & ASSOCIATES LANDSCAPE ARCFUTECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 APPROVED "OR IRRIGATION AND PL.ANTING ONLY, INCLUDIN:. PRECISE LOCATION OF FLANT!Nc; AREA (858) 755-3188 "AS BUILT" RCE __ _ EXP ____ _ DATE AFFF<OVED CITr RECTCL~D WATER 5kiN TO ee USED ON SITE. FIJRPLE BAC!<GROUND IJ)iTH WHIT1: Ll;:TTE~ MOJNT ON. FOST, ANCHORED IN 12 1' p]A X ;,a,n DESF CONCFeTS FOOTINGs. Dier ANCE FROM TOP OF FC&T TO FINISH (Sf"ADE SHALL EallAL 42". Slc.N SMALL eE LOCATED AT AREA& DESl<;NATED 6Y f'LA"l& A"ID AT EACH FIELD SATELLITE CONTROLWSR GROUFIN<S. 6IG"l5 8HALL. eE MOUNTED IN SUCl-l AS A WAY AS TO el: Cl-EARi.-.,.. vls!eJ..I= TO ANYONE O~TING: THE CON~LER. SYMeot.. ON Dtca.AW!N~S AF'F'EAR.S AS. =a= DETAIL AFFEAl'<S ON 51-JEET I-0 REViEWED BY: INSPECTOR DATE LANDSCAPE ARCHITECT OF WORK l----+---t-l'l:.-.J-•'.?J,.._l)_ ...... _~_ ... _"'_""_""'_1>,>o/T'._"_u._k'!?_,.,__--t--+--+1_•_·•'1_·_'~t-"--j I SH2,EET I CITY OF ARLSBAD ~ PLANNING DEPARTMEl~T Ll.2_j :==:.:::::========::::::::.=====: lRR!dAT!ON SdHEDULE$ AND NOTES: CITY, ST.: ENCINITAS, CA 92024 7EL£Pi!ON£: (858) 755-3188 BY: -==c-==-=-----DATE: ____ _ RALPH STONE R.L.A. N0.:~1~4=59~----------- REGISTRA T/ON EXP/RATION DA TE:: ~D=.61~1-5 ___ _ DATE INlllAL ENGINEER OF WORK f DA TE INillAL REVISION DESCRiPTION OTHER APPROVAL DATE INITIAL CITY APPROVAL CT 02-17 SHELLEY PROPERTY "FAIR OAKS V.AL.LEY" APPROVED PLANNING DWN BY: CHKD BY: __ _ RVWD BY: PROJECT NO. CT 02-17 I DRAWING NO. .44051 RECYCLED IRKIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 1 O' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. 0 20 40 80 GRAPHIC SCALE 1 "=20' LATERAL PIPE SIZlNG IS INDICATED BY THE FOLLOWING S'/MBOLS: 1 I,, -II: i \ " ' \ ')" " \/ AS-BUILT DIMENSIONS PROVIDED BY INSTALLING CONTRACTOR RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los VallecilDs Blvd., Suite 204 San Marcos, California 92069 Ph: (760)750-1900 Fax: (760)750-1999 OC1 l<"('Ji.l(lD; U<d~n. f~l;,ne-,ing & 'IJ,;,c,-M;,u;;g.,n1,mt INSTALL IRRIGATION VALVE, QUICK COUPLER, GATE VALVE B•)XES AND ANY OTHE IRRIGATION CONTROL DEVlCES A MINIMUM OF ONE FOOT FRO,, THE EDGE TRAIL EDGE WITHIN A MULCHED MAINTENANCE ZONE. LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: (858) 755-3188 BY: -~=~==-----DATE: ____ _ RALPH STONE R.L.A. N0.:~1~4=59~----------- REGISTRA T/ON EXP/RAT/ON DATE: _0_6rl_15 ____ _ 10-9-14 SML 1 IRRIGATION MODlflC)TIONS 1 DATE INITIAL ENGINEER OF WORK REVl90N DESCRIPTION note: malillne 24• back of toe of elope 27/ SHRUB~ ' 1\" 23 C-11 SHRUB 1\'' DATE INITIAL OTHER APPROVAL I ' DATE INITIAL CITY APPROVAL 18 C-1.2 'S'"H"'RU"'B,v-1" 14 C-13 SHRUB I-1 INSPECTOR KEY MAP y NORTH N.T.S 11 /1 7 /1 7 DATE DATE I SH3ET I CITY OF CARLSBAD ~ 2 PLANNING DEPARTMENT IRRIGATION PLAN CT 02--17 SHELLEY PROPERTY "FAIR OAKS VALLEY"" APPROVED f¾Y/) &-yf\ (\,l.1·11 -PLANNING DATE DWN BY: PROJECT NO DRAWING NO. CHKD BY: CT 02-17 44051 RVWD BY: ,I. -11111,'' I i I: ii I '. I ,I I . // ; . MATCHLINE -SEE SHEET I 37 A-13 SHRUB 1\" I AS-BUILT DIMENSIONS PROV,DED B( INSTALLING CONTRACTOR 1-3 ---- A-24 no« m!I ne e• tn back of lk 1" note: 6" .man • ·bock cf alk FOR MP ROTATORS AT TOE OF THIS S INSTALL ON 12" HUNTER PROS-12-PRS40-CV BODIES. / '----I 31~ sHRU•~ s• In aid RECYCLED \'VATER SIGNAGE / SIGN LOCATION: REFER TO IRRIGATION NOTES FOR REQUIREMENTS. INSTALL lRRIGATlON VAL\£, QUICK COUPLER, GATE VALVE BOXES AND ANY OTHE IRRIGATION CONTROL DEV1CES A MINIMUM OF ONE FOOT FROM TSE EDGE TRAIL EDGE WITHIN A MULCHED MAINTENANCE ZONE. RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 10' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. RECYCLED WATER SIGNAGE '-.....r-::-::~ 26 C-8 SHRUB 1 \" LATERAL PIPE SIZING IS INDICATED BY THE FOLLOWNG SYMBOLS: L } ) 1 0 .. 20 ·1 : •• \ ') \ " L \ NORTH 40 G.RAPHIC SCALE 1''=20' "AS BUILT" 80 11 /17 /17 DATE I-2 INSPECTOR DATE RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECT OF 1 _ 10 __ 9 ___ ,.-l-s-ML---I---IRR-IG-ATI-ON_M_oo-1F-cA_TIO_Ns---------t---l---t------t---J I sH4EET I CITY OF CARLSBAD ~32 >-PLANNING DEPARTMENT ~ ~'=='-======::::::::::::::============'-'=== LANDSCAPE ARClllTECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Vallecitos Blvd., Suite 204 San MaltOS, Colilornia 92069 Ph: (760)750-1900 Fax: (760)750-1999 FIRM: __n.RA"'L.r:PLlH~S<-1"-"0L!!~E--"'&~A"'S,,.S,,,O-"'Cl""A-'-'TE=S'-------- ADDRESS: -1.1,!'34:,;,5'-'='E~-"'C;,:IN11.cl T,,::A'='S-'B""'L"'VDec-_;#:.,6'-"J"'-O ____ _ CITY, ST.: __;;,[lJ.Nl<!CluNILLn .. s"-, ..,.Ccc,A____,9""2""02c.c4-'---------- TELEPHONE: ---"(8""5"'8,_) .:..7,::55=--~3~1-"'88=-------- BY: ---~=~----DATE: ___ _ RALPH STON, R.L.A. N0.:---1.1:,:,45~9.__ _________ _ REGISTRATION EXP/RATION DA TE: _,,Q"-6 lul"'-5 ___ _ APPROVED FOR IRRIGATION AND PLANllNG ONLY, INCLUDING PRECISE LOCAMN OF PLANTING AREA DATE INITIAL ENGINEER OF WORK 1 REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL IRRIGATION PLAN CT 02-17 "FAIR APPROVED PLANNING OWN BY: CHKD BY: __ _ RVWD BY: SHELLEY PROPERTY 0 AKS VALLEY" PROJECT NO. CT 02-17 11-z.-r.11 DATE DRAWING NO. 4405-L ;llilli \ ~24 ~SHRUB W,\ \~,i --\\' f- 24 Sl:IRUB ... I I ~/ /! -! t -' -- >"' I' ' , I RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS, INSTALL TO PROVIDE A MINIMUM OF 10' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. AS-BUILT DIMENSIONS PROVIDED BY INSTALLING CONTRACTOR --'i-t..,_".,: ¥~,. ! "'P. ~ ------i <i ,:1 '..; -----:_~ '" / :l">n--#/ ,,.-1-,,, < ___ _ RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Vallecilos Blvd., Suite 204 San Marcos, Gal~om\a 9206ll Ph: (760)750-1900 Fax: (760)750-1999 OC1 lrrig:;,f,)n D,•01-::yri. l'lar,ning & ,,v, It<, /Ac<•,n:,y,•,1,>-'ral _'I-------- ~ __ / // LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: ___]_13""4"'5'-"E,N,,C,,,_JN.J.!_1,_cTA,.,,SccBs,,L'--'\ll"-D .'--""#6""3"'0 ____ _ CITY, ST: __.£_.N,.,.C,,_1Nu.l"'[A~s~c~A~9-Z~D-24~------ TELEPH0NE: ---"(8c,5c.=8L) ~7=55~-~3~1~88~------- BY: -=-=:-cc==------DA TE: RALPH STONE R.L.A. NO:_____,1-"45eo9:__ _________ _ REGISTRATION EXP/RATION DA TE: _,,0"-6lu1_,_,_5 ___ _ 10-9-14 sML DATE INITIAL ENGINEER OF WORK I ' ! ' IRRIGATION MODJFICAlONS DATE INlllAL DATE INlllAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL REVI~ ~ S:c--~~# INSPECTOR 38~ SH~ 11 /17 /17 DATE DATE I SSET I CITY OF CARLSBAD PLANNING DEPARTMENT IRRIGATION PLAN CT 02-17 "FAIR APPROVED {£r PLANNING DWN BY: CHKD BY: RVWD BY: SHELLEY PROPERTY 0 AKS VALLEY" -. i::;L,., ll-Z1-t1 DATE PROJECT NO DRAWING NO. CT 02-17 44051 I I I I I I ' I 32 1\" SHRUB B-.14 g 1 \" SHRUB AS-BUILT DIMENSIONS PROVIDED BY INSTALLING CONTRACTOR 96' Aqua Commercial Irrigation 810 Los Vallocilos Blvd., &Jite 204 San Marcos, California 92069 Ph: (760)75().1900 Fax: (760)750-1999 FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS CA 92024 TELEPHONE: (858) 755-3188 BY: --=~=~----DATE: ___ _ RALPH STONE R.L.A. N0.:-'1"'4""59"------------- RtGISTRA 710N [XPIRA 710N DA TE: -"OC!.\6'-"/1"'5 ___ _ ----------- I . rJ ]l ·, ! w-\ .. v I ' / / / I RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 10' CLEARANCE BETWEEN THIS LINE AND THE P:JTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LATERAL PIPE SIZING IS INDICATED BY THE FOLLO\'ING SYMBOLS: r--" 1 \ ' 0 I 0 NORTH 20 40 80 GRAPHIC SCALE 1"=20' "AS BUILT" 11 /17 /17 ------- EXP. 05/31 /18 DATE 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" I APPROVED wd ____ t_"'C~-=:--,--_.,.G"'!'v=---e:i=t=A..,_,_,_ __ u-z,. ,, t=====1====1=:===========================~=====~===~~====~===~ ~P:;LA;:N:=N;:IN:::G::====:;-;::=:=::~:;:::::::::;::~=~;::::,:;:;:;DA~T~E:,:;:;:; 1 DWN BY: ___ PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: --CT 02-17 44051 OTHER APPROVAL CITY APPROVAL RVWD BY: DATE INITIAL ENGINEER OF WORK REVISON DESCRIPTION I I ; '' Ii I .41-1 29 1 " SHRUB / 41-3 ~ \..,. _1_" ..... ~P""" LATERAL PIPE SIZING IS INDICATED BY THE FOLL0\\1NG SYMBOLS: I I II: I\" \/ AS-BUILT DIMENSIONS PROVIDED BY INSTALLING CONTRACTOR Aqua Commercial Irrigation 810 Loo Val~los Blvd., Suite 204 San Marcos, California 92009 Ph: (760)750-1900 Fax: (760)760-1999 w z OC1 lrri:.itko,1 D0~i-;)1, Pl;;innirig t, t..\t11•:r Milf'Mj€:j)t.mi LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: __{§"'5"'8)'---'-'75=..=5c...-:c..3c.=18"°8 ______ _ BY: __________ DATE: ____ _ RALPH STONE R.L.A. NO.:___c1.:c45"'9'-------------- REGISTRATION EXPIRATION DATE: ~0,,,61~1=5 ___ _ APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 1 O' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. NORTH 0 20 40 GRAPHIC SCALE 1''=20' "AS BUILT" EXP 05/31/18 80 DATE I-5 INSPECTOR \\· 2.,.11 DATE SHEETS 32 , _,o_-9_-_,44s_M_L -+-1_'"_"'_GA_TIO_N_M_o□_,,,_c,_TI011_s ________ --t--+---J---t-----i I SH7EET I CITY OF CARLSBAD '"" PLANNING DEPARTMENT ~===-'===========::::::...:::::::===; IRRIGATION PLAN DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISON DESCRIPTION OTHER APPROVAL CITY APPROVAL CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED l¼ (:_ . t2.i,\ tJ, z. T. ~l PLANNING DATE DWN BY: PROJECT NO. DRAWING NO. CHKD BY: CT 02-17 44051 RVWD BY: / / / / / / I ',/ I / ,' / / KEY MAP ; ~ NORTH N,T,S, =--== :12. ( .. --. ·. 4.6-.·.1.·· .. ·.··.>. SHRUB 1" .· ' .. RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATIC~.LL Y ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 1 o' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. AS-BUil T DIMENSIONS PROVIDED BY INSTALLING CONTRACTOR 46-4 1" .46~3. 1 " SHRUB 4 SHRUB " I' 11 LATERAL PIPE SIZING IS INDICATED BY THE FOLLOWING SYMBOLS: [;; -I 1 I " Ii i I L \_/ RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Vallecilos Blvd., Suite 204 San Marcos, caI~omia 92069 Ph: (760)750-1900 Fax: (760)750•19119 OC1 1rd(ia( tr-,n ,;','.l,Jr. r:~rmrrg &/J~ste, r,wl1cJ.gc,rnent LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A IES ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: [NCINITAS, CA 92024 T£LEPHONE: (858) 755-3188 BY: ~~~~~----DATE: RALPH STONE R.L.A. N0.:~1~4=59~------------ REGISTRA TION EXP/RATION DAT£: -"o,,,B/..,1""5 ___ _ ------------ 1 DATE INITIAL APPROVED FOR IRRIGAlloN AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA (( DATE INITIAL ENGINEER OF WORK REVISIJN DESCRIPTION OTHER APPROVAL - NORTH 0 20 40 80 GRAPHIC SCALE I '=20' "AS BUILT" 11 /1 7 /17 ~-"-Lfs~-J..l.-l-----1•~ ,,,_ ~~~-- (~ EXP 05 /31 /18 DATE I-6 DATE I SHSET I CITY OF CARLSBAD Lill PLANNING DEPARTMENT 2 IRRIGATION PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED (¢...?'/, & tll...a¾ (1.21.11 PLANNING . DATE DATE INITIAL CITY APPROVAL OWN BY: PROJECT NO. DRAWING NO. CHKD BY: CT 02-17 4405L RVWD BY: 1, I ;' i : I I RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 1 o' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. ! , / , I RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation B10 Los V~ledlos BM!., Suite 204 San Marcos, California 92069 Ph: (760)750-1900 Fax: (760)760-1999 AS-BUil T DIMENSIONS PR0\>1DED BY INSTALLING CONTRACTOR I LATERAL PIPE SIZING IS INDICATED BY THE FOLLOWING SYMBOLS; ,--)l ·1 \" \ ,, I I 1 J; II \ \ \ LANDSCAPE ARCHITECT OF WORK 04--16-1 ML FIRM: RALPH STOtf_E & ASSOC/A TES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY. ST.: ENCINITAS. CA 92024 TELEPHONE: (858) 755-3188 BY: DATE: RALPH STONE R.L.A. NO.: 1459 R[G/STRA TION EXP/RATION DA TE: 06/15 DATE INITIAL ENGINEER OF WORK LOT 20 & 24 FnCE LOCATION RE\r1S10NS 1 REVGION DESCRIPTION 35 SHRUB note: mainline .2,._• back of toe of slope C-3 1 \" INSTALL IRRIGATION VALVE, QUICK COUPLER, GATE VALVE BCXES AND ANY OTHE IRRIGATION CONTROL DEVICES A MINIMUM OF ONE FOOT FRO~ THE EDGE TRAIL EDGE WITHIN A MULCHED MAINTENANCE ZONE. 33~ BUBBLER~ DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL 4~ SHR1JB\,,_,£J A-33 1 " RECYCLED WATER SIGNAGE {J NORTH 0 20 40 80 GRAPHIC SCALE 1 "=20' "AS BUILT" 11 /1 7 /17 DATE IRRIGATION PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" I APPROVED PLANNING DWN BY: CHKD BY: __ _ RV\\'D BY: PROJECT NO. CT 02-17 lt-i.r-11 DATE DRAWING NO. 4405L \ RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMArlCALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 10' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. AS-BUILT Dl~ENSIONS PROVIDED BY INSTALLING CONTRACTOR 10 34-3 ii \ I I \ ------ illlllllllllill MATCHLINE ... SEE SHEET 1-9 RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNJA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Vallecilns Blvd., Suit,, 204 San Marcos, California 92069 Ph: (760)750-1900 Fax: (760)750-1999 OC1 ll'rigm':Hl D2·';Jn, Planning iJ,." \,\J'J: •~r ~,1;:i "hl!) .•n,::n I :r $2 -JS _.----------·· --·· ~------------_,., ------ ,, • LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS, CA 92024 r • Si r • • r r Si e IRRIGATION MODIRCATIONS I I 1,, ' I ' I \ I I I I \ \ I I I I \ I \ \ I APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA I I I \ I \ I I I I I I I I I, I I I I \ I \ \ ' I ' ' ' ' ' ,I i l<EY HAP y NORTH N,T.S. LATERAL PIPE SIZING IS INDICATED BY THE FOLLOMNG SYMBOLS: r-u ' I 0 I Ii ii ~ NORTH 20 40 80 GRAPHIC SCALE 1 "=20' "AS BUILT" EXP. 05/31 /18 11 /1 7 /1 7 DATE \-\.W-u;;>-l-1-I-----I, 18_ 'i" icpires ~ '- 1-8 INSPECTOR DATE UQJ 0 CITY OF CARLSBAD I SHEETS I PLANNING DEPARTMENT 3 2 IRRIGATION PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" . -TELEPHONE: (858) 755-3188 BY: __________ DATE: RALPH STONE f-----+---+-------------l------1------l-----l---~ I APPROVED ~ · .• E::.\\.a:: PLANNING 9= R.L.A. N0.:~1~45=9~----------- REGISTRA TlON EXP/RA TlON DA TE: ~06"'/~1~5 ___ _ 1 DATE INlllAL ENGINEER OF WORK REVSION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: PROJECT NO. DRAWING NO. CHKD BY: CT 02-17 4405L RVWD BY: --------, . ' -,-------- 13 SH~UB I I I I I B-28 1" MATCHLINE -SEE SHEET RECYCLED IRRIG. SUPPLY LINE RECYCLED IRRIGATION PRESSURE SUPPLY LINE IS LOCATED DIAGRAMMATICALLY ON THESE DRAWINGS. INSTALL TO PROVIDE A MINIMUM OF 10' CLEARANCE BETWEEN THIS LINE AND THE POTABLE LATERALS AND STREET MAINS. REFER TO DETAILS FOR CROSSINGS. ORIGINAL SLEEVE / TO REMAIN I BAN< 1-8 note: malnllne ,i.' from fence 52-11. 9 1· SttRUa 52-, 12 16 LATERAL PIPE SIZING IS INDICATED BY THE FOLLO\IING SYMBOLS, i-,\) 1\" ·,/ I \ \ /'. i " ! ! 2 ., V I " l\/ I AS-BUILT Dl~ENSIONS PROVIDED BY INSTALLING CONTRACTOR INSTALL IRRIGA110N VALVE, QUICK ::OUPLER, GATE VALVE BOXES AND ANY OlHE IRRIGAllON CONTROL DEVICES A M111~UM OF ONE FOOT FROM THE EDGE TRAIL EDGE \'!THIN A MULCHED MAINTENINCE ZONE. RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECT OF WORK FIRM: RA/ PH STONE; & ASSOC/A TES ADDRESS: ~1J~4=5~E=N~C=IN~IT.~A=S~B=L~VD=·-'#"'6=3=0 ____ _ IRRIGATION MODl:lCA TIONS LOT 52 IRRIGATlilN ADDED APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA f-------t--+----------------+---1---+---+---l LANDSCAPE ARCHITECTORE • .Pl.ANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 CITY, ST.: __._[N"'C.clNcul.1.1.TA:,,.Si.., _.C"'A~9,..2""02.c:4,:___ ______ f------+---+----------------__j----+-----l-----l----1 Aqua Commercial Irrigation 810 Los Vallecilos Blvd., Suite 204 San Marcos, California 92069 Ph: (760)750-1900 Fax: (760)750-1999 ZIC1 lrig~tio•·, Dt.•~i,::J'I, i>l,:rnning 8' \Nc,\\;r /f,trl<.1·}\:'f!l<onl TELEPHONE: -'-'(8"'5"'8)'-'-'75"'5_-"-31"'8-"-8 ______ _ f-------t--+----------------+---1---+---+---l BY: __________ ,DATE: RALPH STONE R.L A. NO.:-'l'-'4"'5"-9-------------f-,D"AT"'E,-J'l"Nl""ll"A'L +'"'1"'-----------------+~D~A~TE-+-IN~IT=IA~L-+-DA~T=E->-l~N=ITl~A-L_.j REGISTRATION EXP/RATION DA TE: __..o.,6,_/,_,.15,__ ____ ENGINEER OF WORK RE\ISION DESCRIPTION OTHER APPROVAL CITY APPROVAL NORTH 0 20 40 ' I \ 80 GRAPHIC SCALE 1''=20' "AS BUILT" 11 /17 /17 DATE I-9 DATE [jTJ CITY OF CARLSBAD ~ 1 PLANNING DEPARTMENT 2 IRRIGATION PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED /v"2f_j , 6-, ~\\ _..cit ll-z.,,11. PLANNING DATE OWN BY: PROJECT NO. DRAWING NO, CHKD BY: CT 02-17 4405L RVWD BY: , .I I ,-----r---_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--=-.-_-_-_-_-_-_-_-_-_-_--=-.-_-_-_-_--=-.-_-_,-----------------------------------------------------------------------------------------------------------------~ ITEM _! ' ' 4 ' ' , ' ' "'_Qd!,__W,ti._~~~l'Q~~!,~ --- FQ]l MAINTENANCE N01HS: INSTAUATION FER i ----------o,< Ol'lfWDSIDS?EC• SBENUTE!i J. NO OL'tl.ETii WTIJ. Im AU..O\\'ED DI 'l'.!:re PJJ>D.'<i BlffWB!iN ·nm MBTEJ:. AND lJACKJ.WW PREVENTER. BACKFLOW l'REv:ENTE,R SHAll 13[ ntE SAME SIZE AS THE ME'JT,Jt A.'-;1) Pll'ING TO THE A.SSJWBLY. A Pltll'!SURE REGULATOR MAY RE INSTALLED BETWEE.>;; T.aE MEllll AND HACKl'l..OW PJ!.l,V~TEL CUSTOM!iR IS JUlSFONSlliU. FOR ~AINrnNANCE FROM m:F. MR'.fElt 2:. BRASS. PTPR WITH 11-lREADIID Fl'l"J7NGS. RAVlNO THE SAME! C.:QNll!Ol.'ll.ATION \.IAY'IW tJSt'.D lN 1.nm (}F Tiffit:OPPER WATER TI}BB. 3. :PROVIDE CUA.RD POS'TS ANDl()R H.l'sCLOSlJRh WillN D£RECTED BY THE DISTRlC'J'S REl'Rf'.SE!\"T'ATIVR -4. UM\\.'b ~l'f...""NANCE.RESPONSIRILTIY :;l1DPS AT TI-IE METBR 5. NO OTillill. PJPING OR lfIT[JTffiS ARE ALLOWBD wrrmN DACMOW PltBVtNTJ.!11. INSTAl..I.ATIO~ AREA. SPEC, WG : ASSEMBLY OLIVENI!AIN MUNICIPAL WATER DISTRICT l5220 1¼20 152?.0 """ !Sllll lSJJ) 1Sll2 151 !2. BOYLE REDUCED PRESSURE BACKFLOW PREVE!fl'ER STD DWG NO. ~ri~r1/iii1~-Wcii ASSY FOR SIZES 3/4-INCH THRU 2~lNCH C-2,l lt!NEJMII 0 BACKFLOW PREVENTER NTS Q\ICK COUR.ER SHALL i3E OF A TYF'E AF'FROYED FOR RECYCLED WATER LlSE. ~11 ROUND FURFLE VALVE eox e~D 1-1acu INro vALve e-ox LID. f'fFER TO TleCHNICAJ. 6FISCIFICATION&. VALVE eox TO REf>T ON C.RAYEL Si.JMF'. $14" CRU&>ll!D cr.taAVEL 6u11F' • 6" MIN. DleF'T!-1 QUICK COUPLING vALve --- VALVE eox COVER 5HAl..l.. 615 AN INTE<SliAI- F't.lRPLE COLOR Win.I f'fCLAIMED WARNINc.& AND SECU~O WlTl-1 A SOLT TO Tl-IE VAL.VE BOX 150D.,..r ~--RECLAiMEP UJA~ CAF COVEFil: ~lTI • • • LASCO <>1>~·218 UNITIZl!lD I" S\IJING, JolNT Al'8g!-!i3L Y +----Iii" x ~611 GIALvAN.lZED SiEEL 6UF'f'Ol'<1'FIFIS '------------SERVICE TEE SxSxT -90!.YeNT WELD 01'< C.Ael<JSTED FITTI"""-R.El'ER TO TECHNICAL 5FECIFICATION5 FR!!&&Uf'f SUF'PI.. Y LINE • RECLAIMED ~----------PURPLE PIFIS RECLAIMED &T&TEMS <>ET VALVI: i90X LEVEL IN Fll!LATION TO 81Jl<l<OIJNP!NG C.RADE!. I NOTE, NO POT A,BLE QVC'S PROPOSED I ~QUICK COUPLING VALVE ~ NTS ~ Rl=CLAIMED STSTEMS USE !'<SCI.AIMED VE!<f>ION Of 1-!UNTER a.EAR DRIVEN !<OTOl<f> A5 INDICATED IN TH!o I.Ea.END. r---------SET HEAP FERPENDICUI..AR TO &RADE IF E>:011 Opii1, QREATE:fi!. ANC:d..E TO 51..0F'E e:.AADe l~ u:sa THAN 60M~ CURI!> AND &UTTER ( OR SIDISWAJ.K/ IU-!ERS AFFl.lCAi3LE n---MIF'><FIP MA!<I..E>< WELL 12/ -12~ SC!-l. ea, PVC 'NIPPLE SCI-I. 41Z> F'VC SOL YENT WELD ____ _,,. NOTE, NIFF'LE AND HARLE>< FITTING, DIAMETER& TO le<OUAL t<OTOR INUST DIAMETER. FJTTING 0 POP-UP ROTOR gi------ NTS RECT/\N<;Ul-AR V,t,j,.Vl: l!!OX WIT!-1 -------~ EXTENSION • i3RA'ID '1'1V" INTO VALVE !>OX LID. R.El'ER TO TECl-lNlcAL SPECIFICATIONS. FINle,.J cr.taADE • CHRISTY'S RECLAIMED -- WATER Tki PRESSURE REraJLATING ELEcn-,lc CONT~L VALVE ---¥-,---;,;;;i"\ CONT!'<OLLE~ ">'I-Gol. IN. Ol1<5CT ~AL 11.111£ ~.QC~CG'l,.Oft -TIE TC! a..A1X IWII!: ~ AT GQ.;TMUJ211 SLIF'xMIPT SCH. 4"' F'VC ---ff-~ 1~---l---'1A' ~ ~"'1!1-IIU'I" ,_ dJ.1"'1'. APAPTOR 12) FR!!&&URE 5UF'PI. Y LINE RECLAIMED PLIRF'LE PIPE FOR RECLAIMED UIA TER SYSTEMS. AF'F'FIOYED C.EOTEXTILE FILTER FA13RIC 3i4~ ec~eNJ:O ~va. 6UMF' --------' 2 cu. n. CONTROL WIRING ---------------' ~ MASTER VALVE AND FLOW SENSOR 0,----N-T~S------------------------- ~ RECLAIMED &Y&T51"1& U61i RAINel"'1:> !u>.z> NF' <NON-FOTAElLE) COYeR ON IOOIZ> SF'RINKLER ioODY. rt-+--------SET eoTTOM a: CAP AT UR.A-DE CURe • a.LITTER OR SIDEWALK UMERE AFPL!CAioLE ~---------1.1211 )( 211 eci-+..ao PVC NIFPJ...E V~=---------ll2" MIF'xFIF' MA!OLID< ~IZ> ELL (2) ,__ la· MIF'xFII" MARLEX ... ELI- ,_ __ 501.YENT WELD &CHA<Z> PVC FITTINc. ~----PVC LATERAL PIPING 0POP-UP SPRAY SPRINKLER 6 NTS ------· 5ET LIP AT FlNl5H GRADE ---lb "7 ~ 111m1 ii 11i 1111-1111 illl 1111 NIPPLE, LENC:!TH A5 REQ'D. MIFxFIF MARLEX ':10 ELL (2) ..... -- 5Cl-l. 4/Z> FVC SOLVENT UJELD _____ ,,. ----1-cuFse AND GUTTER ( OR 5IDEUJALK> WHER!:: APPLICA6LE ~---12" 5CH. e-izi PVC NIFPLE MiFxFIF MARLEX ,i0 ELL PVC LA-ERAL PIPING NOTE, NIPPLE AND MARL.EX FITTING DIAMETER5 TO EQUAL ~OTOR INLET DIAMETER NOTE, WHERE HEAD5 ARE LOCATED ADJACENT TO WALL& A!>IOIOR FENCE&, HEAD5 5HALL 6E OFF51:T 12" AWAY FROM WALLA=ENCE ~O 1-H __ I-_P_O_P_-U_P_R_O_T_O_R ______ _ '-J NTS WHERE <;ATE VALY!il 15 U61:D AS A FART CF A RECLAIMED WATER 5T5TEM, VALVE !>OX COVER S~ALL l9E AN INTEc.RAL F'U~E COI...O~ wln-t Ri:CLAlMED W~lNC:;6 .ANO SECLIREO W)TI--I A !90LT TO THE VALVE eox SODY' AND ii-IE CHR.l5T'T' RECTCLED WARNn,i,:; T"6 SHALL l9E ATTACHED TO WE VAi.YE STEM. 4" \\fioLl!:!==---11Z>" ROtlND vALY!:l eox 6~"-IP 11(l\/~ ON l..lD O!= VALVE !SOX. Rl=FER TO Ci4RISTT'6 RECLAIMED cl TECHNICAL SFECIF!CATIONS. VALVE 60:X TO AEST ON C.RAVl:L 81JMF. WATER TAG. ----314' &CFIEENED GRAVEL 51.lMf' I CU. PT. . " C ----&" CLAS& 16.z>PVC &l.EEVI: \, • • q ll !>OTTOl1 TO l9E Pl-Al'<EP b . AND CONT AcT TOP CF ,-:.C..-f:=l"'r-W:r f:iir"i==---, FRE5eu;;,.e SI.IPR. Y LIN!e ~--F'VC FR!!581JRE SUPPLY LINE ~----&LIA<MIFT SCi-1,W PVC ADAMO'fii: (2) ~-----GA'fE vALve Wte!<Ae5 CRO&& HANDLE 0GATE VALVE 2-1/2" AND SMALLER 3 NTS ,..,_,.._ _____ 5ET BOTTOM OF CAF AT GRADE LOCATE 12" AWAY FROM WALLS AND OTHEI-? VERTICAL 5Ufs!=ACE5. ····-CURB AND GUTTER OR SIDEWALK UJHERE APPLICABLE 1-1-1llttaH ... 1 .------~-12" HI-FOP $FRAY HEAD I~---PVC LATEl-1AL 5CH. 40 PVC FITTING, ~-----FLEX FIFE NOTE, 12" FOP-UF &PRAY HEAD& TO BE PLACED FOUR FEET /MIN) FROM EDGE OF CUR6 OR &IDEUJALK, Ao Fl:R CITY GUIDELINE&. 0 HI-POP-UP SPRAY SPRINKLER 7 i-N_T_S ___________________ _ CHR!STT'S RECLAIMISD WHERE THE MANUAL DRAIN vALve I& USED A& A F'AfsT CF A !ECLAIMoD WATER lW5TEM, VALVE !90>< COVER &HALL. E>E AN INTEGRAL PLIRFLE COLO!'< WITH RECLAIMED WA~INc.& AND 61iCUREP WIT~ A eoLT TO THE vALve eox !¾>DY. ,--------------F'VC LATERAL -4& EI.L TO F'ROFEl< PEF'Ti-1 • R.El'ER TO TECHNICAL SFEclFICATION&. ,----------RECTA"lGULAA VAi.YE !SOX. eRAND WATER TAc,. ----LID UIITi4 CONTT<OLLER •STATION~ REFER TO TECHNICAL &FECIFICATIONS. VALY!il aox To REST ON C.RAVl:L eUMF. r m 1 111 f'INISH GRADE r-",;-\i"'H-ft---PVC GRAT eALL VAL ve 1~11!~ I I I It!!~~~~ VAL VI! SIZE X CLOSE SCH. !l<!l F'VC Nll"l"LE (T'rF'ICAL). +-+llf---SCH. 4"' l"VC 9"> ELL &Lil" >< SLIP t..::._'--c_..,+-i,r,,-\l,\----PRE&. REG. ELEClli'IC CONTROL VAL Y1il c,:, I) 0 1/,,1'--HJL..-L:J+-3-14~ SCREENED GAAV1=L ... 0 ii1Cb 0 ~ SW1'1P • 2 CU. rT. "--"CJ..----:l.4l--"--..... J?'!f','-.,,.-----5Cl-l. ~ f'v'C FIFE:, LEN'=r:Tl-t AS REGUtRED ---T-L,--J::l:::==--::AlFI ;,;I ~""'VED GEOTEXTILE FILTER FA!SRIC. EX'tEND IIZ>" UP VAL VI: !>OX EXTERIOR WAI.LS • ALL &IDES. ~----SERVICE TEE • 501.VEl'IT WELD OR C.AeKETED FITTING -REFER TO SFECIFICATION& ~------FRE55URE SUF'R. T LINE -RECLAlt-:1:D PURPLE PIPE F~ RECl..AlMEO 5''f5TEMS NOTE, DIAME'!'e"'8 OF RISER FITTINC.S, IOALL VAi.Vi: AND NIFPLE SHALL EGlUAI.. CONTROL VALV'e D!AMETE~ LOOP ALL &FA:fcE WIRES I"~ CON.TROLLER lN:5-10!: EACH YALV'E 00><-~" DIAM~;-SR LOOP (MIN.I GELECTRIC CONTROL VALVE 4 NTS CHRISTY'S ADHESIVE RECYCI..ED UJATER 1..A6EL FINi5H Ci.RADE / FACE OF &LOPE MP ROTATOR ON FRE55URE !<EOOLATINC. 5HRU6 60D'r OR 5F'RAY 5FRINKLER W/ FA·e&-NF ADAPTER ON~" X 12" (ABOVE C.RADE! Rl5ER INSTALL PLUMe T0 TOP OF 5LOFI':, FERFl"IDiCULAR TO FACE: OF 5LOFE. r----HUNTER HCV CHECK VALVE t'n"'\.----5CH ~ PVC TEE """,-l'tii OR ELL FITTINe:.. 5CH 412> PVC FIFINC. ·-ecH 4/Z> oTREET ELI.. fa\ SPRAY SPRINKLER ON RISER ~-N~T~S------------------- RALPH STONE & ASSOCIATES AF'PRO\IED FOi'< IRF<JGATION AND f'LANTINC. ONL 'r, INCLUDING. PRECISE LOCATION CF PLANTING AREA LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation .lf!fJII" ,~~~l 810 Los Valle<l!os Blvd., SuHe 204 San Marcos, California 92069 Ph: (760)750-1900 Fair (160)150-1999 & Wi!ll<f M<lnl'.g.eu-1.:nt ... -.... "'" ~ "AS BUILT" RCE EXP REVIEWED BY: INSPECTOR Lill CITY OF AR BAD 2 PLANNING DEPARTMENT IRRIGATION DETAILS DATE DATE Lill 2 ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENciNITAS, CA .92024 TELEPHONE: (858) 755-3188 CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED BY: __________ DATE: ___ _ RALPH STONE PLANNING R.L.A. N0.:........,,1-'-'45,c.,9'-------------- REGISTRA TI0N EXP/RATION DA TE: ......,,o.,,6/wl.,_.5 ___ _ DATE iNITIAL ENGINEER Of WORK 1 REVISION DESCRIPTION DATE INIT!AL DA TE INITIAL OTHER APPROVAL CITY APPROVAL D BY: CHKD BY: __ _ RVWD BY: PROJECT NO. CT 02-17 DRA ING Nci: 4405L DEPTH 'A' NATIVE &OIL A& ~------APFROYEO iOAc;Jq'ILL Wt MtN.IJ& 1/411 MA TER:lAL.. l<E"5R TO encil"ICATIOS FO~ COMPACTION f<EQUl!<EMENT&. F<!iC'f'Cl.50 WATER WA!<ING TAFE /IN = PLACE&) • ON ---k----"1~ TOP Of PRE&.?-UFie 8UFPl. Y LINE AND i,' 6Et.OW GRADE OYER P!aES!lU!<E 8UPPI.. Y LINE SLEEVE& UJl<i=f<E PIPING C!<COOI=& ROADWAY& use 4~• FITTINGS TO ACI-IIEVE !<EGi.11!<50 DEPTH A& NOTED FOi< 61.EEVE&. NOTES, ...... ~~lj~ lATEAAI. PIPIN:.; PURF'J..E PlaE500!<E 8UF'F'L 'I' LINE ~----1½' OR $MALLER • SCI-I 4i?'J PVC 2" OIO LAIOGEI'! CL 31& F'VC CONTROL WIRl'Na, eaow ...___ __ P!aESSU!<E SUPFL Y UNE L ALL PLASTIC PIPING TO BE SNAKED IN n-ENCHES 2. 6UNDLE AND TAFE WIRING AT lo!>' INTE!'t'VALS. 3. iNeTALL ALL CONTF<OL A'<D COMMON Wll'<ING TO THE sloe AND E>ELOW THE FRES6U!<E SUfT'L '1' LIN!:. IN&TALL FRE56UIOE $UFF'L Y LINES AT DEPTH 'A' AS DESCF<i61=D E>ELOWa Ll=SS THA'l ll' DIAMETER FIFI=, 3" • ~.!;" DIAMETER FIFI=, 6" ~ c.!<il=ATER DIAMl=TER FIFI=, -4. fa!;QUIRED SLEEVING DEFTl-lS. Dl=SCRIFTION OF SLEEVE, SLEEVES UNDEFI. ROAD&. !&11 COVER 2411 COVER 36" COVER DEPTH, 6 11 OR LESS IN D1.41'1EiS:~ 3&11 COVEFi;; GREATER THAN 6" IN DIAMETE~ 4&' COVEFI. SLEEVES UNDER PAVING iNON-ROADSJ MATERIAL, SCHl¾l>PVC SCH l¾l' PVC LESS THAN 3' IN DIAMETER lb" COVER SCH ~ PVC 3~ .. e,~» ~ DIAMETER 2411 COVER: SCH 40 PVC E>" OR GIOEATER IN DIAMETER 31!>" COVER SCH 4" PVC &. SLEEVING TO EXTEND I," i!!EYONP EDGE OF ADJAc5NT PAVINc.. GTRENCHING 11 NTS ,-------------PVC LATEAAI. • 45 ELL TO FROPEIO DEPTH • REFEIO TO TECHNICAL SPEciFICATIONS. ,-----------RAINS)~ EASY ~lN BATT!:;R"I' OFEAATED VALVE CONTROLLER· PROVIDE ~y ALKALINE 6A TTER.,- ~--------RECTANGULAA VALVE eox. "1'sAND LID w1rn CONTI'<OLLER • STATION ~ IOEFE!II TO TECf.lNICAL 5FeCIFICATION&, RECYCLED WATER NOTES L ALL VALVE !30XE5 51-!ALL. 6E FURA..E PLASTIC WITH THE UJORD6 ''RE CYCl.ED WATER" CAST INTO THE PLASTIC LID. 2. ALL CONTROL VALVE6 MU&T f.lAVE A PLASTIC LA6EL ATTACf.lED W TIE Wl<AP WITH THE UJORD5 ''RECYCLED WATER • DO NOT DRINK IN 1TH A NYLON ENGL 151-l AND SF'ANISi-l 3. ALL A60VE • Gl'<OI.IND RISERS SHALL 6E LA6ELED WITH A SELF-AD LABEL WITH THE 5AME WARNING AS THE LAE>EL FOR CONTROL VAL i-,ES)VE YES. 4. ALL FLU5H, POP·UP SPRINK!..ER HEADS MUST 6E MADE OF FUFsPLE PLASTIC. 5. ALL BELOW GRADE FIFING MUST ee PURPLE PIPE WITH THE WORDS WATER • DO NOT DRINK".THIS APPLIES TO !30TH PEl'!MANENT AND PRES6URE PIPE. THi5 REQUIF<EMENT DOES NOT AFl"L Y TO FITTIW..5 "RECYCLED INTE!OMITTENT AND RISERS. 6. 00 f.lOSE 6165 ARE ALLOWED ON RECYCLED WATER 5Y$TEMS • ,. QUICK COJPLERS AIOE ALLOlLED, euT MUST ALSO BE PLACED IN PU RPI.I= PLASTIC VALVE eoxee. a, NO ON-51Tc: 6ACKl'LOllJ PREVENTION M,5!3113L Y SHALL 6E All.OWE F<ECYCLED WATER 5'1'5TEM SERVING LA'JD&cAPE, TIJl<I", OR C!sOF DON ANY IRRk,ATION- l'IEQUIIOED CLEARANCE ElETWEEN FOTAl:'>LE AND RECYCLED WATEI'< FEET f.lOl'<JZONT ALLY AND I FOOT VEl'<TICALL T (WITH POT A!31-E WAT C1'!05Slmo P!cRPENDICULAR!. Y OVER RECYCLl,D UJATc:R LINE). IF A llJATEFI. LINE CROSSES OVEI'< A FOTA13LE UJATl,FI. LINE. Ti-,E RECYCL LlisE 5f.lALL BE INSIDE A SLEEVE WITH THI, SL!:EVE CENTl:RED 0VE FOTAE>l.E WATER LINE AND E><Ti=NDED AT LEAST 10 ltl:T ON 130TH LINES IS lo!> ER LINE RECTCLED ED WATER R THJ;c 5IDE5. CONT AcT OLIVENHAIN MLINICIPAL WATEFI. DISTRICT 13ACKFLOW fa!;C'I' CLEDWATER DEPARTMENT AT /1E>i:?l,li,;2--423S / (160,li,32·-42~ r----------------3/4" F1=6CO MODl=L 11& ATMOSFl-!ERIC VACUUM 13 Ri=AKl=R IZI= Fl=R FLAN ,-------------5CI-I 4"' FVC UVR l=LL, 6 NOTE:, NO VAL VE OF ANY TYPE MAY 13 DiSCl-!A~E SIDE OF Tl-IE ATM05Fi-lER INSTALL ATMOSFHl='RIC VACUUM 61"EAKE E INSTALLED ON Tl-II= iC VACUUM 6REAKl=R. RAT Ll=A5T "'" 6T!<EET 6UfaFAcE PoTAE>LE 6T!<EET MAIN ~ ~ I i;;• ' ,, ~· 7 ~ REC'YCJ..ED WATS'il: iR!'<IGATION MAINLINE IN SLEEVE NOTE, ALL. RECLAIMED WATEIO IR!OIGATION Fl""" AND SLEEVES SHALL. SE PURPL.E AND LAeELLED AS 5F1!CIFIED IN THE 5TANDARD SFEcirlCATION5 FOi'< Fl"IVATE l~bAT!oN OY&TS'-iS WATEfi. DISTRICT ~56 ANP Rf:®LATIONS FOT CONSTii!UC"l'iON OF Fl!:CLAIMED WATER MAh-1& OCTOBER 1eea RECYCLED WATER @TABLE SERVICE LINE CROSSING 12 NTS HOA maintained areas (valve 828): PRESSURE LOSS CALCULATIONS: QUANTITY SIZE D!=SCl'<IFTiON PSI LO&Sfi.00 FT. PSI LOSS I 2" METER 4.':I ···----------···· 1112 LF 2.&" SCH 40 PVC MAINLINE IA$P51/l00LF I R-P. e,Ac;KJ'LOW PREVENTER ~-"o!> &2' !ELEV. ELEVATION CHANGE 36£).i> "'. I , vALVE eox To RE&T ON &RAVEL SUMP, ~_J'~-1-,t---;c--.--------p"~f1n ~rr, 111 FINISH GRADE i-!161-!EI'<: TI-IAN ANY SFRINKLER IN Tl-II= '-" MIN. 5Y5TEM 5ERVl=D 6Y Tl-II= 1111111111 2' MIN.•4" MAX. ~ 3" Tele SCH a.i, NIPPLE ill/:: I ..-Je-L-'U~-,--LJ!ll...-"L, ...--+,---SCH. 40 FVC ~" ELL SLIP X SLIP cP ~----SERVICE TEE· SOLV5NT WELD OF< GAe!<ETED FITT!Na, • IOEFEI'< TO SPl!CIFICATION& ~------PF<E85URE SUPFLY LINE HOMEOWNERS ELECTRIC CONTROL VALVE G W/ BATTERY CONTROLLER 14 NTS AVl3. n f'OF-UF OR SPRAY 1-!E:A ON RISER SPRINKLER D tfillb~~---[Ii~~iillj~l';I,:,,;--. ~------FINISI-! G,RADI= -~tER4---r=~~,--3'fEli'E1~T':SC"----SCI-I 4.i, PVC RISERS, SIZ "-'TIJ,, -1.c,,; 1T1;;-· FLAN, Ll=NG.Ti-1 AS RE:QU E FER ·:11-----1· "--J-----'• -----------TO CONTROL VAi.Vi= HOMEOWNERS @AVBVALVE 15 NTS RALPH STONE & ASSOCIATES LANDSCAPE ARCITITECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 Aqua Commercial Irrigation 810 Los Va0ecrros Blvd., Suite 204 San Marcos, California 82069 Ph: (760)750• 1900 Fax: (760)750-1999 IRED. l=R FLAN 1/J!!? ffCI lrdgafion De~ajn,Pl1>,,11ini:; Me W<'l;er M;,ri.:,ge,ni,,nt 2rei-1 E'LEV ELEVATION CHA'IGE 5-60 I I" CONTF«'L VAL VE 3.!i>o!) 2 2.&" GATI= VALVES 21?)0 I 2" FLOW SENSOR 21N) I 2" MASTEi'< VALVE 3.!;o!> 48 LF 2' SE!'t'VICE LINE &Al PSl/100 FT. . ...........•. LA TERA!. LINES 6£)0 eue,. TOT AL OF LOSSE&. FRESSURI: REQUIRED AT HEAD, AVAILAe.LE STATIC PRES6URE AT METE!'< /FROM OJllD.! CUl'<RENT POTA6LE CONDITION !<EQUIRED e,ooer IFFI.OM PUMP/ WHEN CHA!«iED WI FOT AE>LI:, l'!EQUIRED e,ooer /FROM RJMP/ WHEN CHAi.<iED WI RECYCLED, PUMP FACTORS: DYNAMIC INLET DYNAMIC INLET INITIAL POT AaLe RECYCLED 6Y6Tl=H, WATER SYSTl=H, &2 PSI AvAILAaLE IS PSI AVAILA6LE AT PUMP INLET AT PUMP INLET FLOWB& 6PM FLOWB& Gf'M l'<EQ'D PRESSURE REQ'D PRESSURE 6005T '3& Pi!>! E>OOST IU> PSI AvAILAe.LE El.EC, AvAILAeLE ELl!C. 4M> VAC, 3 PHASI! 41¾l> VAC, 3 PHASE PUMP, llJATERT~ICS l" l!-'1 l<r f:I> LA..11/D~CAPE ARCHITECT 0~' WORK FIRM: &,~/ PH S.IONE ,;I; ASSOCl/l TES ADDRESS: 1345 ENCINITAS BL VD. ll.630 CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: (858) 755-3188 BY: DATE: RALPH STONE R.L.A. NO,: 1459 /1\ DATE IN!TiAL ............. 5ID5WAL.I<: CURS Ml:T!i.R WITl-1 METE.R OOX 24' ~~~ W#h'.'. s-11 A~X.. ( ) ' F'OT AE>Lo SERVICE L.INE ~•· MINIMUM r. lo!>' MINIMUM WATER IR!OIGATION MAINLINE UJlTH SLEEVE I RE:CYCl..a:> WATER IRRIGATlON MAINLINE WITH &!.EEVE NOTE, VEl'"TICAL CLEARANCE OF Ill" MINIMUM I& MANDATORY WH!SN CIOOSSING FAT~ OF A POTAe>LE WATEFl LINE. IN5TALLATIO>I ON !<ECL.AIMED WATEIO l"""ksATION MAINLINE 24" MINIMUM ~ FAcE OF SIDEWALi<: WILL PROVIDE THE NECE5MR"I' lo!>' OF l<OF<i:zoNT AL CLEARANCE FRa"1 THE PoTASlE MAINLINE IN THE STREET. RECYCLED WATER @POTABLE MAINLINE CROSSING 13 NTS Home Owner lots (lot 48, valve 48-3): PRESSURE LOSS CALCULATIONS: ··-·- Sl.leTOTAL LOSS/GAIN -----····---------·· QUANTITY 511'.1= DESCRIPTION FSI LOSS/1.i>o!> FT. PSI LOSS sue,TOT AL LOSS/GAIN 4.':I I I' METER 1.6 1.6 ----------------------·· 2!'>.S3 1&2 LF t2!;1f SCH 40 FVC MAINLINE L!l1 FSl/li:?l.i> LF 21>4 ~£)0 lo!)' ELEV. !aLl':VATION CHA~!= 4.S3 4.S3 361N) I I" CONTROL VALVE 2..43 2..43 e.s.io -4E> LF I" SERVICE LINE 10..41 PSltl.i>.i> FT. 4.:a 3.!;<!> LATERAL LINES 3A 3A 41N) UX> -•----~---- 3.!;o!) 2.&S 61?)0 101.42 SUI'='· TOTAL OF LOSSES, 21"}~.8 -'-01?)0 Pf'!;5SJRE fa!;QIJ!fa!;D AT i-,EAD, 4"-""11 6 ~ POT IU>.00 RE AVAILAeLE 6TATIC PRE65URE AT DOMESTIC METER 12.l?)o!> PGT W PSI UJ/ e& 6PM RESIDUAL PRE65'JRE ll.<!>2 excess 116 PSI Wt 8!> 6PM 1.lsNDsc-<1-" "AS BUILT" ~• STO¾t, )f <v.<,; '~ ... 1l lM~keI: 2: I "' • ,,, rt:. . <:> RCE EXP DATE i-J(~~;' APFROYED FOi< iioRIGATlo>I AND <l',.., ' '5 FLANT~ ONl..'T", !NCJ..i.lD)NG ~clei:: r. ,,,.J ~ REVIEWED BY: LOCATION OF PLANTING AREA ~ l"ali ~' t:A~lto'<'- I-11 INSPECTOR DATE -l--1,b;> ,.,.:,,~_1-'0]'.'E,.'S 12-'~.i ... ~ ITf] CITY OF cARLtiBAD 1 5325 1 .............. PLANNING DEPARTMENT 3 IRRIGATION DETAll.$ AND SPEdIF'IdATIONS CT 02-17 SfIELLEY PROPERTY -··-·········· "}'AIR OAKS VALLEY" ............ .................... ·······-APPROVED ,~.J. r ..,,,. ~_:k {-1.•1~-r".) PLANNING . DATE DATE INITIAL DATE INITIAL OWN BY: PROJECT NO. (858) 755-3188 I I 4R4~~GL NO, CHKD BY: CT REGISTRATION EXP/RATION DA TE: Q6i.td REVISION DESCRIPTION ..... 02-17 ENGINEER OF WORK 01HER APPROVAL CITY APPROVAL RVWD BY: l'OI< Rl:CLAiMl:D 5YS11:MS USIS RECLAIMED VER&ION OF IOAINel!<D GEA!'! Dl'!IVEN l'!OTOR& A5 INDICAlED IN THI! LEGEND. GEAR DRiVEN ~To,;l ON &11 ~ISl::R IN5TALL 1,z,• D0'1NHILL FA5T FEl'!FIND ICULAI'! TO SL.OPE ON SLOPE FACE. INSTALL FLUM6 AT ToP OF SLOPE. Nate: EQUIPPED WJTl-4 / INTISGl'!AL CHEO:: VALVE \\ .,..-.. l'!ECYCLED WA1EI'! WAl'!NING VINYL ZIF TIE, INSTALL IN 'f'JJO (2) --... STICKEi'! FOi'! RECLAIMED FLAcES AS 5HOILN. WA rE" $Y511:M5. SCJ.l 4" LIVF< PVC TISE 01'! ELL FITTh-G. LIVF< PVC FIFING! HUNTER MINI-Cl.lK IN G ROTOR ON GRADE 16 NTS ~---&ENSOR GUARD ENCLOOORE l!"'!""'!!!!l"""'""'il!!E'!Fil WIRE PER MANUFACT. SPEC. STAINLESS STEEL FLIP TOP LID, $f.lOUJN IN OPEN f>OSoTION ET 2<Z>IZ'!Z> CONTROLLER --- CONTROLLER. E:NCLOSURE AND ALL OF Tl-IE Rl:GUIRED COMPONENTS Sl-lALL 13E PART OF A PRE-A56E:M6LED CONTROLLER A56E:M6L 'f CONTROLLER, ENCLOOORE • DIMENSIONS WHEN CLOSED, CAL6EN$E TP-ll<Z> SUR::.E ARRE$TOR 1rirl=110==::'.:::::::::::;Ji J 35"!-I x l6"W >< I&.&" D __ _. -~ ____ STAINLESS STEEL, UL 'l:.l!!J -LISTED, PREDRILL!::D, POUER SWITCH ---~/ 0 0 0 REMOVA6LE 6ACK80ARD AND Rl:CE:PTACLE I ____ CAL61:N6E: TP-1 TRANSIENT &TAINLE$S STE!::L PROTECTION 60ARD II!>" WIDE TOP-ENTRY •~, CONTROLLER ENCLOSURE i' ---____ TERMINAL 6LOCK5 FOR NEMA 3R RAINPROOF RATED ---COMMUNICATION CAeLE WI DOME ANTENNA • "" , "i!> OOLID COPPER GROUND TP•I TRANSIENT ___ _,,-\.: , ----wlF<E: CONNECT TO G,RD. TERMINAL PROTECTICN !:>OARD ' UJ/ TERMINALS FOR VALVE ----120 YAC JUNCTION eox WIRES ,,,,_ -~-.. · .• ,, ,:_ '.1-;,;;;,;----FINieHED GRADE Rl::MOYAeLE • ',, , . , ,::'• ',i II~ I f>O"="D r~•c="TE PAD FRONT PANE:L 11TTT1 2---l'll-lHf--11-1 .. _,'' 24"~~4" ';;eJ DEEP NOT Sf.lOUN SLOPE EDGES TO DRAIN ., • I 1/4" PVC CONDUIT/$l!EEP l '----FOR ELECTRICAL SERVICE ~--:0" PVC CONDUIT FOR i CONTROL WIFsES TO VALVES '~-----!Mo" DIA x 6' COFFER GROUND ROD W/"l<Z> GROUND WIRE AND 6RONZE CLAMP W/IN FVC $LEEVE TI-IRLI 6LA6 L....------1" PVC CONDUIT!5WEEP FOR FLOIII SEN6CRA1CV WIRES '---------1" FvC CONDUIT/61.iiEE:P FOR ET GAGE WIRE&, WHERE APP'L '----------1" PVC CONDUITl!lWEEP FOR TELEPHONE LINE, WHERE APP'L I l/4" PVC CONDUIT FOR COMMUNICATION CA6LIE TO OTHER CONTROLLERS @ CONTROLLER ASSEMBLY (1 of 3) 17 NTS ~------l<Z>" !'<OUND TAN VAL VE eox I 61'<ANP "CKV" IN LID. -Uf'J.llLL !~Ill -FINl61-l C.RADE I =illl 1- 12" MIN.11----1!2)" ROUND VALVE eox l r· ·-PVC DRIP LATERAL FIFI: IL: : \ I -------FLOW l ,_ ------FLO CONTROL PVC 6UJIN6 Cl-ll:CK VALVE 61:Rli:6 1!:'>21Z>, 5 X 6, LINI: 61ZE. OR EQUAL 1-0C:ATED ON ALL 1-ATERAL I-INE6 EVERY TE:N(l<Z>) VERTICAL FEET OF ELEVATION C:l-lANc.E B SWING CHECK VALVE 18 NTS j l!2)" ROUND TAN VAL.Ve eox eRAND "CKV" IN LID. Tn ~ii;::='.==::;Jli--~-----FINISH C.RADE 1 lll!m!Jl!JT I ~ /ll ==Jilli I;;" I== ~• 12" MIN.11---- j j ------1D -PLOW l!2)" ROUND VAL VE eox PVC OR POL 'f LATERAi.. PIPE '-----'KING 6ROS. INDUSTRIES' "KC" 5FRING, CHECK VAi-VE, 5 X 5, LINE SIZE. AD AFT TO FOi-'f FIFE A5 REGl'D. G SPRING CHECK VALVE 19 NTS SECTION e>2810 IRRIGATION SYSTEM PART 1 -GENERAL 1.01 SCOPE A. Provide labor, material and equipment for the underground lrr19at1on S!;jstem lncluc:Hng the follow1n9: I. Trenching, stoc1<p1J1n9 excavated materlale, and refllllng trenches. 2, Complete s::istem lncludlng but not llmlted to: piping, valves, fittin9e., spra::J heade, rotor, heads, pipe stablllzatron, controllers, and wlrln9, other mlecellaneous lrrl9atlon e9u,pment, and flnal adjustments to Insure efflcient coverage, as determined b::J Owner's Representative. 3.Connectlon to backflow preventer. 4, Replacement of unsatisfactor!:i materials &. Cleon-up, Inspection, and approval. i&. Teete. 1.02 RELATED oECTIONo A. oectlon Ol3e>O -SubmTttale. 6. Section e>1100 -Contract Cloeeout. C. oectlon 02200 -Ec1rthwork. D. Section 02920 -Soil Freparatlon, E. Sectlon el2':l3e> -Lawns and Grasses. F. oectlon 02':!SIZ> -Trees, Flc1nts, dnd Groundcovere. 1.03 REFERENCES A Ferrorm Work In c1ccordance wlth c1ppl1cable laws, codes, ordinances, rules c1nd re9ulat1ons. 6. Conform to re9urremente. of reference Tnformallon lrsted below except where more str1n9ent re9uirements are shown or specTfled in Contract Documents. I. American Soclet:,J for Tee.ting and Mc1terla le. ( ASTM) -Specfflcdtlone and Test Methods epeclflcall:1 referenced Tn this Section. 2. Underwr1tere Laboratories (UL) -UL Wires c1nd Cables. 1.04 QUALITY ASSURANCE A. 6pecTc1I Re9u1rements. I. Work involvTn9 substantlal plumb1n9 for Tnstallat!on of copper piping, backflow preventer(s), and related Work shall be executed b!;i licensed and bonded plumber(s). Obtaln necessar:i permlte prior to be91nn1n9 Work. 2. Tolerancee, Speclfled depth& of mains c1nd latera Js, c1nd pitch of pipes dre mlnlmume. Settlement of trenches ls cdu&e for removal of finleh grade trec1tment, ref1ll1n9, recompactlon, and repc11r of flnleh 9rade treatment. 3. Coord1natlon Wrth Other Contracts, Protect, maintain, and coordlnate Work with Work under other Sect!one. 4. Pc1ma9e to Other lmprovemente, Contractor shall replace or repair damage to grading, sol! preparation, seedln9, soddln9, or plant1n9 done under other Sections dur1n9 Work associated with !nsta llc1tron of Trrlgatlon S:,Jetem at no c1ddTtlona l cost to Owner. &. Manufacturer's Speclflcatlone, Follow current printed Specifications and Praw1n9s Tn casee where manufacturer's cover items or lnformc1tlon not epecif!ed or e,hown 1n the current documents. i&. Commun1cat1on cable, All Ra1n Meister -Control S!;jstem communlcatron cc1ble lnetallatlon and splrcrn9 shall be tested and certified Tn wrrt1ng b:J representative of' Raln Maeter or a representative of 1-1:JdroScape Products. Inc., Calriornra. 6. Explc1nc1t1on of Draw1n9e. I. Pue to the scale of the Draw1n9s, Tt Te not possible to Indicate offeets, f1tt1n9s, sleevee, etc. which ma:,1 be re9u1red. Cdrefull:,J lnvestr9ate the condltlone effectln9 the Work and plan ac=rdln9l:1, and furnish re9u1red fittin9s. Install 5:J5tem Tn such a mdnner to avoid , ' confllcts with plc1nt1n9, utllltles, c1nd architectural featuree, 2. Do not lnsta II the irr19c1tron s::istem as e;hown on the Drawlnge when lt Te obvious 1n the field that obstructions, grade d1Herencee or dlscrepanclee ln dlmeneione exlet. Bring euch obstructions or d1fferences to the attentTon of the Lande.cape Architect.. In the event thle notlflcatlon ls not 91ven, the Contractor shall assume full responslbTlit:,J for necessar!:i revlslon, as determined b!;i Lc1ndecape Architect. Le>& 5U!3MITTALS: Prepare and mc1lce submlttale In c1ccordc1nce with the conditions of Sectlon e>l3e>e>, Submltta le, and those specif'lc re9ulrements lleted below. 10,u WE ARE CONSERVIN~ OUR MoST VALUABLE RESOURCE BY IRRl~A TIN~ OUR. LANDSCAPE WITH RECYCLED WATER @ RECYCLED WATER AGUA RECICLADA DO NOT DRINK NO TOME EL AQUA ~ = £! . i' GAL.V. CARRIAGE --601.T W/ L.OCK WA$14ER AND PENTA /VANPAL Rl':51SV NUTS• 2 EA ~~" DIA GALV. PO$T WITf-1 CAP FINl5l-l GRADE 12" DIA X .:l!Zl" DEEP CONC. FOOTING @RECYCLED WATER SIGNAGE 20 NTS A. FroJect Record Drawin9e. L At onset of ,rrTgatlon inetallatlon, Contractor shall eecure dlazo m:1lars of orlgTnal irr19c1tlon desl9n from Owner. Hc1lce bluellne or blackllne prrnts for ever:,J week on ProJect. At end of ever!:i da~, revlee prfnte for Work accompllshed that da::J in red ink. Record drawings shall be brought up-to-date at close of working da!:J on ever!:i Frlda::J b::J a o,uallfled draftsperson. An up-to-date P;lnt shall be _rev1ewed with Owner'e Repree.entc1trve and Landscape Architect at the weekl:J progreee meet,n9. An add,tronal print of' record plan(e) ehall be given to the Landscape Architect. Indicate zoning chan9ee on weekl:J record drawln9s. Dimene.lon from two permanent pornts of reference (bu1!dTn9 cornere, sldewalk, road intereectlons or permanent structures), location of followlng Items, a. Connection to exiet1n9 welter llnes. b, Routing of pressure euppl!;i llnee (dlmenslon ever:,J 10@ feet along routln9>. c. 5prink!er control valves. d. Qulck coupl!r,9 vc1lves. e. Drain vd lvee. f. Control wire routing (if' not with preesure mc11nlrne). h. Gate va Ives. 1. Communication cable routing. J. Control wire and communication cable spllces (1f not inside fleld controller). k. Note 9uantit:J and location of spare control wlree. , _ , . I. At compfetlon of project, contractor shall provide completed ae-builte to the Lc1ndsc~pe Arc~1tect. 2. Final lrrlgat!on 'ae-bullt' plane will be reciuired to be reviewed and c1pproved b::J the Cit:,J and final m:ilars will be re9ulred to be approved c1nd s19r,ed b!;j the Cft~ prior to Plc1nn1ng Department e19n1ng the permTt card. 6. Controller Drawrnge. I. Obtain cop::i of completed record draw1n9 for preparation of controller draw1n9s. 2. Provide one controller draw1n9 for each automc1tlc controller Tnetalled. a. Drawing ma:1 be same size reproduction of record drawln9, 1f scale permite flttlng lnerde c~trol(er door without foldin9 draw1n9. If photo reduction printe are re9ulred, keep reduction to maximum size possible to retafn full le9lbllit!;j. b. Drawing shall be bluellr,e print of actual record drawln9e, showln9 area covered b:J that controller. 3. ldentif!:J area of coverage of each remote control valve, uelng a distlnctl:,J different pastel color for each zone. Hl9hl19ht heade, lateral plplng, and control valve. 4, Follow,n9 review of controller drawrn9s b::J Landscape Architect, hermet1call:1 seal each chc1rt between two la~ers of 20 mm thick clear plastic sheet. &. Controller drawrr,9s ehc1II be completed and approved b:J Landscape Architect prior to flnal completion walk-through of lrr19atlon s~stem. i&. Attach approved controller drc1wln9e; to Inside of each controller door. WATEl'!Tl"ON CS aooeTE" PUMP STATION WI ENCLOSUl'!I!! 48<ll·3·65· II!> MOPEL • CL rev-I!>- 5TATIQN COMPONENTS, A PUMP A"ID MOTOR 6 Cl-JECK VAL VE C FRE&eURE TRANSDUCER WITH C.AUC.E SEE LOCAL D 6'!'-FA55 VALVE E FLOW 61:NSOF< NEC CODl:5 F TEMP SENSOR e:;· STATION FAN 1-lOOD MOUNTED l-l Fl.IMF INTAKE ISOLATION VALVE I PUMP Dl&Cl-lARa.E ISOLATION VAL.Ve J STATION Dl5Cl-lARC:il: iSOLATION VALVE K MARINE C:iRADE ALUMINUM ENCL05URE L PRESSURE C.AUC.E L.IG!UID FILLED M DEADFRONT 5ERVICE Dl5CONNECT p I PVC I STEEL Pl5CARG.5 AND SUCTION "Z" 3• SCH 4~ FIFES :3" FLANC.E CONNECTION DISCHA....e &fEEI.. 'Z' - Fl'!OYIDED o>Y WATERTRONICS /'ltatlon Model # CLTBV-15-480---3-·-85·-115 To Produce: 85 OPM ® 115 PSI of Boost Horsepower: 15 Station Di~charge Isolation Valve: 3" Power Requirements: 480V, 60 H0, 3 Pha$e Flow Start l>" ecJ.l 40 STEEL 'Z' INLET -----~ Fl'!OVID!=D o>Y WAlEF<TRONICS w ~ Ill 't <(\ L 6 4 '"' 1-l !:'>4" SASE /MrD c- llJlSC[lt,,+EC:T I/ • = • • • '""' I I • ~ -j • I '~ • -.. . I ~ A' • '-• • . F E "'" ... J_ • "'" • I J • INTAKE AND Dl&cHA R<;i= FIFING, Z INCLUDE WIT>-! Fl-MP CONCl'!ETE FAD El'r CONTRACTOR a.FM AT II& FSI OF !SOO&T. FOJ.ER 4B<ll STATION PACKAGE. PUMP DELIVERS a& VOLT 3 FHA&! CONT ACT, PETE 6E AUDOIN • WATE=Nlce, (B(Z),2)) 3&6-6606 ' m Q L ,. $Cl-<4/I) Pl'!OVIDED 612'11 X 42•1 X STEEL 'Z' Dl5CHA- 6T WATEl'!Tl"<ONICS 4" THICK CONCl'!ETE PAD WATE1'!1'1WNIC& eoDSTE!t FUMF -1-------+------~ STATION Ill/ ENCLOSUI'<!! MODEL.• CL T6Y•l!;•4eel·3·65· Iii> 3" SCH 40 STEEL FIFING "?" TO il'!l'!la.ATION SYSTEM Fl'!OVIDED l!IY WAT!=1'!1'1WNIC5 3 11 e,e,14 M P\IC P:l..ANGE YAN !;TONE STYLE WIT>-! i'!!=Gl\Jll'<!!D J.lAl'!DWAl'!I!! AND a.A&l<ETED INLET AND OUTLET. ADAPT TO 2.5" SUPPLY LINE. PVC &T!aEL Al. rEl'NAT!= ACCEPT Af'lLE AJi'1F MANUFACTUl'!ER AND MODEL, l'!EF!aR TO RAINSIRP QUOTE, CYMO~l6l3 6!2>3A CONTACT 5f¼u.NA i90i'<TOLU&oi AT (1601214-31>36 5TEEJ. I PVC @o BOOSTER PUMP ASSEMBLY NTS AF'Fl"OYl'D FO" ll'!l'lia.AT)ON ilJ,O FLPNTINQ ONLY, INCLUDING, Fl'!ECleE LOCATION OF PLANTING, Al'!EA RCE. __ _ REVIEWED BY: I-12 INSPECTOR "AS BUI LT" EXP·----DATE DATE LA,,~D$CAPE ARCHITECT OF WORK ~ ITY OF ARLSBAD fSl:l..E~ 1---l----1---------------t---t--·t----t----j Ll1J PLANNING DEPARTMENT ~ RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Vallecitos B!vd., Suite 204 San Marcos, Ca!tfomla 92069 Ph: (760)750,1900 Fax: (750)750-1999 FIRM: .BA.IPH __ $JQNE; __ !LASSQ,..CIAa.7r"""'-S ____ _ ADDRESS: 1345 ENCINITAS BLVD. #§JO CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: (858) 755-3188 BY: --,,,.=-:-==;c-----DA TE: ___ _ RALPH STONE R.LA. N0.:_____,_14-"'5=9 __________ _ REGJSTRA TION EXP/RA noN DA TE: _..0,,_6 ( .. 1 .. 5 ___ _ DA1E I ITIAL ENGINEER OF \VORK REVISION DESCRIPTION DATE 1Ni11AL DATE INITIAL OTHER APPROVAL CITY APPROVAL ::=::::::..:=:::::::::::==============.:::::::~ IRRIGATION DETAIL$ AND SPECIFICATIONS CT 02-17 SI-IELLEY PROPERTY "FAIR OAKS VALLEY" PLANNING D N BY: __ _ CHKD BY; __ _ RV BY: PROJECT NO. CT 02-17 I DRAWING NO. 4405L c. Operation Manual. 6ee 6ection 01700, Contract Closeout, Paragraph L07, for de&criptlon and tlmlng of Operation Manual eubm!Hal. Include the followrng !nformatlon, L Index e.heet e.tatJng project name, and listing compan:1, address, phone number and contact person of Owner, Landscape Architect and Contractor, Including FrTmar:1 Sub-Contractors. 2. Written Instructions for operation and maintenance of pumping e9uipment, .3. Manufacturer's Technlcal Manual for controllere.. 4. Manufacturer cut sheets for heads, control valves, CJUlck coupllng valvee,, gate valvee., controllers, and valve boxee.. L01f> Joe SITE CONDITIONS A Protection of Fropert!:j. L Preserve and protect trees, plants,, monuments., structures., and paved areas, from damage due to Work of this Section. In the event damage does, occur, damage to inanimate 1tems shall be completel:1 repaired or replaced to satl&faction oi Owner. lnjur:1 to llvlng plants sha II be repaired b:j Owner, and costs of such repairs shall be charged lo and paid b:j Contractor. 2. Protect buildings, walke., walls, and other propert:1 rrom damage. Flare and barricade open ditches. Damage caused to asi:,halt, concrete, or other building material surfaces shall be repaired or replaced at no cost to Owner. Reetore d!&turbed areas to orrgrnal condition. e. Exletlng Trees. L Trenching or other Work under iTmb spread of evergreens or low branching deciduous material shall be done b:j hand or b:j other methods so as to prevent damage to limbs or branches. 2. Where it ls necessar!:! to excavate adjacent to exlsting trees, exerclse care to avo1d lnjur!:J to trees and tree roots. Excovatlon ln areas where 2 lnch or larger roots occur shall be done b::J hand. Roots 2 Inches or larger in diameter, except d!rectl!:j ln the path of pipe of conduit, sholl be tunr,eled under and shall be heavil!:j wrapped with burlop to prevent scorrlng or excess!ve dr~lng. Where a trenching machine ls operoted close to tree& having roots emaller than 2 inches in diameter, wall of trench odjocent to tree shall be hand trimmed, maklng clean cuts through roots. Roots I !nch and larger In diometer eha ti be painted with two coats of ''Tree Sea I". Trenches adjacent to trees e.ha II be clo&ed within 24 hours, and when this Te not poeelble, side of trench odjacent to tree shall be kept ehaded wlth moistened burlap or canvae. C. Protection ond Repoir of Underground L!nes. L Re9uest proper utillt~ compan:1 to stake location or underground electrlc, gos, or telephone llnes. Take whatever precautions are neceesor\j to protect these underground lines from damage. In the event damage does occur, Contractor sha II repair damage, and Contractor ,;ha II pa:1 costs of such repairs unless other orrangements have been made with Owner. D. Replacement of Paving and Curbs, Where trenche!) and )Jnes crose existing roadwa\:js, paths, curblng, etc., damage to these shall be kept to a mrnrmum and shall be reetored to or19Jnal concHtlon. I.ell WARRANTY/GUARANTEE, Controctor shall warrant materials agarnet defects and guarantee worl<.manshlp ror a period or one ::iear from date of F!nal Completlon acceptance. Contractor shall be responsible for coordinating materra I warrant:1 ltems with manufocturer/dlstrlbutor. A 6ettllng of backt!lled trenches whlch ma::i occur during guarant:1 perlod eha II be repaired b:j Contractor at no expense to Owner, including complete restorot!on of damaged propert\j. 13. Expenses due to vandalism before Final Completion occeptonce shall be borne b:j Controctor. C. Frovide cop:j of worrant:1 form on compan\! letterhead with operation and molntenance monuals prior to flnol acceptance. D. Contractor to be responsible for weekl!:j vlsual observation or backflow preventer& during freezing temperatures whlle s:1stem Is under warrant:1. Freeze damoge during warront:1 to be repolred b:j Contractor at no coe,t to Owner. 1.08 MAINTENANCE MATERIALS A Furnish the following maintenance Jtems to Owner prior to Fina I Compleuon acceptance (unless specTffcall:j deleted from Work 1n wr1ting b:j Owner), I. Two (2) set& of special tools re9urred for removing, dlsassembl1n9, ond adjust!ng each t:jpe of sprinkler head ond va Ive suppiled on this Project. 2. Two (2) four-wa\l screwdrrver&. .3. Two (2) ke\:js for each outomat1c controller. 4. Four (4) 9urck coupler ke!:J5 and two (2) motchlng hose swivel& f'or each t!:jpe of 9uick couplrn9 valve installed. 5'. Two (2) olum1num droln valve ke:1s of sufficient length for operation of drain valves. 8. Refer to Section 0l1e>e>, Contract Closeout, for other re9u1remente. Le>S EXTRA STOCK, In add It Ton to insta lied S\jstem, furnfsh the fol lowing Items to Owner, A. Flve (S) pop-up spra:1 heads with nozzles of each t!:jpe used, for ever:1 one hundred (100) heads Installed. 6. F1ve (!;,) rotor heods of each t::ipe used, for ever:1 one hundred (100) heode Tnetolled. PART 2 -PRODUCTS 2.01 MA TERIAL5 A. Cienerol Piping. L Pres&ure Suppl:j LTne (from point of connection through backflow prevention unlt), T::ipe K Hard Copper. L Pressure Suppl:j Lines ( down&tream of backflow prevention units.>: Fotoble S:jstems, Schedule 40 FVC Bell End <1"-.3">, Class 200 PVC 9asketed end (3" 4 4"), and Class lb0 PVC gasketed end (b" and larger). 2. Non-pressure LJnes, eelow Girade 5!:jstems, Schedule 40 PVC Bell End. Above Girode S~stems, Ultraviolet ree,fe,tant Schedule 40 PVC Bell End. Color, Tan 5'. Sleeving, SPR 3S Flae,tlc Pipe. e. Copper Fipe and Flttlngs. L Copper Flpe, T\:jpe K, hard tempered, In accordance with A5TM 134264. 2. Plttlngs, Wrought copper, solder Joint t\jpe • .3. Joints, Soldered w1th solder 4& % copper, !If>% sl!ver, 15 % zlnc ond 24 % cadmium and solldue at 112s·t= and l19u\ds ot 114S'F. C. Brass Flpe and Fittings. !. Brass Flpe, 6S % red broe.s, ANSI Schedule 40 screwed pipe. 2. Fittings, Medium bross, screwed 12!=> pound class. D. Plastic Fipe and FlttJngs. L ldentlflcatron Markln9s. o. ldentlf':j pipe with the foilowlng Jndellble mark1ngs, 1) Monufacturer's nome. 2) Nomina I pipe size. 3) Schedule of class . 4) Pressure rating. 5) NSF (National Sanitation Foundation) seal of dpprovaL 6) Pote of extrusion. 7) Note, When lneta lied, m.srklngs to be face up. 2. Solvent Weld Pipe, Manufactured from virgin pol\jvln:jl chloride <PVC) compound 1n accordance with ASTM D2241 dnd ASTM D1764± cell closelflcatlon 12454-13, T::jpe !, Grade L Onl\j one brand to be used. Do not mix brands Le., Pacrflc Pipe, JM, Cresl!ne. Mlnlmize glue jolnte wherever possible. a. Fittings, 6tandard weight, Schedule 40, lnJectTon molded FVC• compl:1in9 with ASTM Dl764 and D24G>b, cell ciassiflcotlon 12454-13. Onl:1 one brand to be used. Do not mix brands Le., Dura, Lae,co. I) Threads -Injection molded t\jpe (where rectulred). a. No teflon paete to be used on an:1 threaded flttln9s. 2) Tees and Ells -Side gated. b. Threaded Nlpples, ASTM P24b4, Schedule 80 with molded threads. b. Jolnt Cement and Primer, T:jpe ae recommended b\j manufacturer of pipe ond flttlnge. No 121 will be ollowed. Pressure Suppl::i L!ne± use Weld-on 1'711 and primer onl:1. E. Giate va Ives, L Gate Valves for .3/4 lnch throu9h 2-112 lnch Flpe, Brase construction± solld wedge, IP5 threods, and non-rising stem wlth wheel operatrn9 handle. 2.Gate Valves for 3 Inch and Larger Pipe, Iron bod:j, brass or bronze mounted AUJUJA gate valves wrth a clear waterwa:1 e9ual to full nominal d[ometer of valve± rubber gosket or mechanical Jo!nt-t\jpe onl::i-valves shall be able to w1thstond o contlnuou& working pressure oi !Se> psl and be e9u1pped with a sc::iuare operatrng nut. F. Qulck Coupling valves, 13rass two-plece bod:j de&Tgned f'or working pree,sure of 1i:>O psl± operable wfth quick coupler. E9u1p CJUlck coupler with lockrng rubber cover. Manufactured b:j Ralnbird. Uee purple cap for potable and non-potable water. Gi. Vo Ive Boxes, Gireen colored boxes 1.1.1Tth green covers to be Jnetalled In all potoble water oreas. L Giate Va Ives and W1re Stub Sox, Carson-Brooks ll<:lle>. 2 • .3/4 Inch through 2 Inch Control Va Ives, Corson-erooks "141':l-12. .3. Communlcatron and Control W1r1ng Splices, Carson-Brooks ll<:lle>. H. Electrlcol Control W!rlng. L Low Voltage. a. All.k::i UF UL approved No. 14 dTrect buria I copper wire for o II control wires, and No. 12 direct bur1al copper wire for all common wrre&. I) Control W1res -Red. 2) Common Wlres -Whlte. 3) Moster Valve Wlres -Slue. 4) Spare Wlres -Green <labeled at terminatlone). !;) Future Wires -Yellow. b. Wire Color&, c. If multlple controllers are utilized, and wlre poths or different controllers cross each other or run parallel to each other, control wires from each controller shall be different colors. Common wire shall be whlte wTth a differ1n9 color etrlpe for each controller. Colors shall be approved b8 Londecape Architect ond placed on oppoe.lte sldes of trench. d.Control wire connections c1nd splices shall be mode with 3M d!rect bur8 e.pllce, RalnbJrd or 3M Fentite connectors, or slmilar dr:j splice met.hod. 2. 1-llgh Voltage, T:jpe re9u1red b\j local codee1 dnd ordlnances, or proper eTze to accommodate needs or equipment servlced. Must be instolled b\j a llcensed Electrlcal Contractror. .3. Communlcatron Cable, Rain Master communlcatlon wJre sholl be manufactured b:j Rain Master, Inc. a. Hardwire Communicatlon coble between Controller Assemblies shall be Falge Electrfc P-7111-D b. Flow 6ensor WTre shall be "14 ga ULUP direct burial wlre. I. Pleid Sotelllte Controller, Colsense Et-2000e-XX-LR-M-PL-RRe-SSE-R serfes pedestal mounted fleld &atelllte controllers as specifled on Drawings ond Detalls. J. Electric Control Va Ives, Hunter ICV Serles or as lndlcated on Prowlnge. I. Where Jndlcated on the drawTnge;, volvee. shall be e9u1pped with a Rainb[rd pressure regulator. K Sprlnkler Heade, Fobricated riser unite Jn accordance with details on Drawrngst wTth r1eer nipples of same i;Tze as rTeer opening ln spr!nkler bod:j. L 4" to 12" Pop-up 5pro::J Heads, Ralnblrd 1800 Series. 2. Geor Driven Rotors, Manufactured b\j Ralnblrd or os indicated on Draw1n9e. L. Sprinkler Heads, Fabrlcated riser unite 1n occordonce wlth detaTls on Drawings± with riser nlpples of eame s!ze a& riser opening 1n sprinkler bod\j. I. 4" to 12" Pop-up 5pra!:J Heads, Rolnblrd l8e>e> 6erles. 2. Geor Driven Rotors, Monufactured b:j 1-lunter or as lndlcated on Prowlngs. M. Prese,ure Suppl\j F'lplng Locating Tope, Morkllne Tape, .3" wlde detectoble tape, blc;e In color wlth "Coutlon, Waterllne Burled Below" printed on lt. Place b" from finish grade. N. 13edd1ng MaterJal, Washed construction grode eand or similar material approved b::J Landscape Architect. 4" on bottom of plpe, b" on top of pipe. 0. eackflll Moteriol for Lateral Lines, Shall be free of rocks 2" or larger. FART .3 -EXECUTION .3.e>I INSPECTION, Examine areaa and cond1trons under which Work of' thTs Sectlon 1s to be performed. Do not proceed wTth Work until unsatlsfactor::i conditions, have been corrected. A Grading operotlons, wlth the exceptlon of flnal grodlng, eholl be completed and opproved b!:j Owner or Landscape Architect before staking or Tnetallatlon of rrrlgotlon s::istem begins. 13. Contractor to verlf:j locallone and usabTlit\j of sleeves and conduTts ine,talled b:j other trades± report an:1 problems 1mmedlate1:i to Owner. .3.02 PREFARA TION A. Staking sha II occur as follows, I. Mork with powdered g::ipsum or morklrig paTnt routtng of pressure supply !Irie and flag heads and control volve locations for first few zone;,. Contact Land&cape Architect 48 hours ln advance and re9ue&t review of etak1n9. Landscape Architect will advTse Contractor ae to the amount of staking to be prepared. Lands.cape Archltect wlll review staking and dTrect changes 1f' re9u1recL Review doe& not relleve !nstoller from coverage problems due to Improper placement of heads after stoking. 13. lri&tall e.leevJng under concrete walks, prior to concreting operations, to occommodate plpln9 and wrrrng. Compact bac!<..flll around sleevee to 95% Modlfled Proctor Denslt::j wlthfn 2% of optimum moisture content 1n accordance w!th ASTM P\551. C. Trenching, Trench excavat.1on shall follow, a;; much os pos(',fble, lo8out shown on Drawing. Dig +.renches straight and support pipe continuouel\j on bottom of trench. Trench bottom shall be clean and smooth w,th rock ond or9on!c debris removed. Freseure suppl::i lrne trenches ,;hall be over-excovated os re9urred to allow for bedding materral. L Clearances. a. P7ping .3 Inches and Larger, Make trenches of sufficient wldth (14 Tnches mlnlmum> to properl:1 aseemble and positlon pipe In trench. Minimum c!earonce of piping 3 inches or lorger shall be 5 Inches horlzontoll!:J on both sides of the trench. b. Flplng 6ma lier than .3 Inches, Trenchea sha II hove a mrnimum width of 12 lnches. c. Line Cleorance, Frovlde not lees than & lnches of clearance between each l!ne, and not less than 12 Inches of clearance between llnes of other tradee. 2. Pipe and Wire Depth. a. Pressure Suppl::j p1p1n9, L 2 1/2" or less, 18 Inches from top of pipe 2. 3" arid larger, 24 inches from top of plpe. b. Non-pres&ure Flplng (rotor), 12 Jnchee from top of' pipe. c. Non-pressure Plplng (pop-up.>: !2 Inches from top of pipe. d. Control Wiring, Slde of preseure moln and o minimum of 18" deep. e. Communication Cable, Slde of pressure maln and a mfn!mum of 18" deep. f. Fres&ure Suppl\j Locotln<::l Tape, If> Inches from f'ln!sh grade. 3. 13oring will be permitted on~ where pipe must poss under obstructlon(s) whlch cannot be removed. In backfillTng bore, flnal denslt\j of backflll shall match that of eurroundlng soil. It le acceptoble to use sleeves of sultable d1ameter lnstalled first b\j Jac!<..Tng or boring, .;nd pipe lald through sleeves. Observe eame precautions as though pipe were Installed ln open trench. .3.03 JN5TALLATION, Locate eciutpment as near as pos&Tble to !ocot.lone dee.Tgnated within the r1ght-of-wa:1 or within common landscope orea&. Devlotlone e.ho II be approved b\j Landscope Architect prlor to 1n&tollot!on. A. f'VC Flplng, lne,tall prpe ln trench to allow for expansion and contraction. Do not Install pipe when olr temperature le below 40'F. Flace manual drol!'I volves at low polnts and dead ends of pressure suppl:j piping to Insure complete drainage of s8stem. When plpe lo\jlng ls not in progress, or at end of eoch da\j, close prpe ends wrth tlght plug or cap. Perform Work ln accordance with good practices prevarlrng In p1ping trades. Install pressure suppl:j line iocatTng tape olor,g entire length/secllon of pressure suppl:j line. Coordinate pressure euppl:j llne and locating tape lnstallotlon wlth re9urred bedding operotlone. L 5olvent Weld PVC Pipe, Lo:j plpe and make plastlc to plastic jolnte !n dccordance with monufacturer's recommendatlona. No 721 glue wlll be allowed. 2. Ga e,keted End P 1pee, a. La:1 pipe and make p1pe to fTttlng or prpe to prpe Jolnt, foilowlng OR70 re=mmendatlone ( Johns-Manv!lle GiuJde for lnsta llatron of Rlng-Tlte f'lpe), or plpe manufacturer's recommendations. b. Construct thrust blocks behlnd 9osketed fittings, teee, bends, reducers, line valves, and caps In accordance with pipe manufacturer's recommendations. Contact Londscope Archltect prior to placing thrust b!ocke. for observation of thrust block excavat1on ond rnrt1al plocement. Do r,ot preseure test pressure suppl:j hne with thrust blocks for period of 48 hours after insta ll1n9 thrust blocks. Size thrust blocke. bosed on followlng table, AFFROVEP FOR lf<!<l('!,AT!ON AND PLANTINC; ONLY, INCLUDING F'R!!Cl!>E LOCATION Cl' F'LANTI"" AFIEA "AS BU IL T" RCE___ EXP. ___ _ REVIEWED BY: INSPECTOR DATE DATE RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 LAND~CAPE ARCHITECT OF WORK FIRM: RALPH S]QN..,£_,&"-"A""SS""O""C""IAw.TE,a.,S,._ ____ _ ~ CITY OF CARLSBAD I S3HE2ElS I f----+--+----------------+--~f----+---t----1 ;::~==5:::::'...::::::::==P=LA=N:::N=IN:::G=D=E=P:::A=RT::::M=E::::NT===:'..':::===! f----+--+----------------+---t----+---t----i IRRI<iATJON SPECIFldATJONS (858) 755-3188 Aqua Commercial Irrigation 810 Los Va!lecitos Blvd., Suite 204 San Marcos, CaUfornia B2069 Ph; (760)750-1900 Fax: (760)750-1999 ADDRESS: 1345 ENCINITAS BLVD. #630 CiTY, ST.: ENCINITAS. CA 92024 _··········---- 7ELEPHONE: (858) 755···3188 BY: --cc.c-=c--===-=----DATE: ___ _ RALPH STONE R.L.A. N0.:~1~45~9~---------- REGISTRA TION EXP/RATION DA TE: _0.,,61~1=5 ___ _ CT 02-17 SHELLEY PROPERTY 1----+-----1---------+--+---t----t-----i "FAIR OAKS VALLEY" APPROVED /1,4l 4, ~1 .... 1\: PLANNING DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DA TE INITIAL DA TE INITIAL OTHER APPROVAL CITY APPROVAL DvvN BY: --- CHKD BY; __ _ RVWD BY: PROJECT NO. CT 02-17 DRAWING NO. 44051 C. Control Wlrlng. L Low Voltage Wiring, a. eur!:J control wlrlng between controller and electric valves Tn pressure suppl!:J llne trenches, wlth wires consietentl:i located to one elde of plpe, on top of Tn!tra! pipe bedding, or !n separate trenchee. b. Bundle all 24 volt wires at 10 foot Intervals with electrlca) or duct tape. c. Provide an expanslon loop at ever!:! electric control valve locat1on (ln valve box). Form expansion loop b!:J wrapping wire at least 8 t1mee around a 314 lnch pipe and withdrawing pipe. d. Make epllces and E.C.V. connections using Ra!nbird Pentite connectors or .similar dr::J e.pllce method, ins ta I led per manufacturere epeclffcationa. e. Install control wire epllcea not occurring at control valve In a separate spllce valve box. Wires to be continuous from controller to valve, distances permittin9. No unneceeear::1 spllcee. f. Install one control wire for each control valve. g. Run two spare ~14-1 control w1res from fleld eatelllte controller pedestal to last electric control valve operated b::J controller on each and ever::1 leg of pressure euppl::1 line. Label spare wires at controller and wlre stub box. Loop a minimum of 24" from all spare wires Tnslde ever::1 control valve box operated b!:J controller. Spare wires to be green in color. h. Run all future control wlres from controller pedestal to point Tndlcllted on Drawings. Coil a minimum of ten (le>') feet at termination llnd instil II Tn 1@' round valve box. Label all wlres at term1nat1on. Future wlree to be !:lellow Tn color. 2. 1-llgh Voltage Wiring for Automat1c Controller. a. Provide 120 volt power connection to automatic controller per the N.E.C., lnsta lied b::J a j!censed electr1ca I contractor. 3. Communlcatlon Cable, Installed as per controller manufacturer's specifications and detllils. a. Spllces to occur onl~ at controller pedestal unless Indicated on the drawings or approved b::J Lande.cape Architect prior to lnetallatlon. b. Bur~ control w1r1ng between controller and electric valves In pressure suppl~ lrne trenches, with wires coneletentl~ located to one elde of pipe, on top of Tnitla I pipe bedding, or In eeparate trench. c. At the Sub-Mlleter Satelllte Controller (Controller e9urpped with phone modem communication) connect EV-CA6-COM cable to communlcatlon board (DX-HW) within Satelllte Controller assembl!:J to 'OUT' termlnllie as follo1.1;e, =pper wire to 'OUT +' terminal and tinned wire to 'OUT -' termlnal. Extend to next Satellite Controller. d. At next Satellite Controller Tn !Tne connect EV-CA13-COM to communlcatfon board (DX-HW) within Satelllte Controller llssembl!:J to 'IN' termlnllle. as follows, copper wire to 'IN +' termlnlll and tinned wire to 'IN -' terminal. To extend to the next Satellite Controller Tn ITne, connect EV-CAl3-COH cable to communJcat!on board <D><-HW) wlth1n Satellite Controller aeeembl!:J to 'OUT' termlnllle as follows, copper wire to 'OUT +' term Ina I and t Inned wire to 'OUT -' termlna I. Extend to next 51ltel lite Control !er and connect EV-CAl3-COM cllbje as descrlbed above. I. Sensor Communlcatlon Cable, a. Bur!:! Sensor EV-CAl3 SEN Cable between controller and flow sensor valves In pressure suppl~ l!ne trenches, with wires coneletentl!:j locllted to one side of pipe, on top of lnltial plpe bedding, or Tn seperate trench. b. Splice cable wires to flow sensor with waterproof t!:jpe connectors of the t!:jpe specified withln these epeciflcatlone. Connect white wire to wire sensor wire and b!acl<. wire to black sensor wire. c. Shut off power to 51ltelllte Controller. d. At Satellite Controller connect white cable wire to 'Input 1+' terminal and black cable wire to 'input I-' terminal on e,ensor terminal board within the Satelllte Controller assembl!:1- e. Turn power on at the SatellTte Controller and set 'K' and 'Offset' values for the elze and t::1pe of flow sensor used. L. Gate Valves, lne.tall where shown on Drawings and as deta!led. M. Sprlnkler Heads, lne.ta II sprinkler heade where designated on Drllwfnge or where e.taked. Set to finie.h lls detllTled. $pacing of hellde shall r,ot exceed the maximum !ndlcated on Drawing unless re-staked as dlrected b!:J Landscape Architect. In no case e.hllll the spacrng exceed maximum recommended b~ manufacturer. lnsta II heads on double ewlng-Jolnt rlsere; as detailed. Angled nrpple relative to non-preeeure llne eha 11 be no more than 417• or Jess than 10•. Adjust part circle heads for proper coverage. Adjust heads to correct herght after sod ls Tnetalled. Plant placement shall not Interfere wTth lntended sprinkler head =verllge, piping, or other eciu,pment. Consultant ma~ re9uee,t nozzle changes or lldjustments without additronal coe.t to the Owner. No overe.pra~ wTII be perm1tted onto public etreete, lots, wa !Is or other structures. Where it is necessar::1 to reduce the radius of' no;z:zles In exceee of 25 maximum nozzle radius on spra!:I heads, use Ralnbrrd PC5 screens to reduce radius ae described b!:J the manufllcturer'e l1terature. N. eackflow Preventer, Install where shown on Drawings and as detailed. 0. eackfllling, Do not be91n bllckflllTng operations until re9u1red 5!:J&tem tests have, been c~mpleted. eackfiil shall not be done lf excavated material rs frozen. Leave trenches e,)lghti!:j mounoed to allow for settlement aiter backfll!Tng ls completed. Trenchee; sha II be finish graded prior t~ @.ilk-through of 6!:J!llem b::J Landecllpe Architect. 1. Pree.sure su~pl!:J llnes shall be bedded with conetructlon grade sand 4" below Tnvert of plpe, to I&" above top of pipe and width of trench. An::J control wires or communlcatron cable not Tne,talled wlth preee;ure supp l::J !ine sha II be bedded as ellme. 2. Materials, Excllvated materTll! is ger,erail::J considered eatfefactor!:J f'ar backfill purposes llfter completlng bedding re9ulrements. !31lckf111 material shall be free of rubbish, vegetable matter, frozen materials, and stones larger than 2 Tnchee Tn maximum dimension. Do not mix e;ubeoil with topso1L Materilll not suitable for bllckf111 shllll be hauled awa!:1-Contractor shall be ree-poneTble for providing suitable backflll Tf excavated mllterlal Ts unllcceptable or not sufficient to meet backfill, compaction, and final grllde requirements. 3. Do not leave trenches open for a period of more than 48 hours. Open excavations ehllll be protected ln accordance with OSHA regulatlone. 4. Compact backfill to '2!1Z'~o maximum deneTl::J, determined Tn accordance with A5TM Dl5&7 utilizlng the following methods. a. Mechanica I tamping. b. Fuddling or pondln9. Fudcilln9 or ponding and/or Jetting le prohibited wlthln 2@ feet of bur!dlng or foundation walls. F. Piping Under Faving. I. Provide for a minimum cover of 24 Iner.es between the top of the pipe and the bottom of the aggregate base for pressure and non-pressure p1p1ng Tnetalled under asphaltlc concrete or concrete paving. dent during test period. 2. Piping located under areas where asphalt or concrete pavrng wlll be Tne.tal!ed ehllll be bedded with construction grade sand or e9ueegee ( a la!:ler I& lnchee below plpe and I& Inches above plpe). 3. Compact backfill material ln I& Inch ITfte at ':10 % mllximum denelt!:J determined in accordance with ASTM Dl5!:>7 using manual or mechanical tamping devices. 4. Set ln place, cap, and pree,sure test plping under pllvfng, ln preeence of Owner prior to backfflllng and paving operatlons. 5. Flping under ex1etin9 walks or concrete pavement shall be done b~ jllck1n9, boring, or h::Jclrllullc driving, but where cuttlng or breaking of walks and/or concrete le necese.ar!:J, Tt shall be done and replaced at no coet to Owner. Obtaln permleelon and prior approval to cut or break walks and/or concrete from Owner €;,. Flplng under f'uture streets to be Installed In sleevee 24 Inches below future flnieh grade. D. Automatic Satellite Controller. I. lneta II =ntroller In accordance with manufacturer's lnstructlone as detlllled and where shown on Drawings. Gl. water Suppl~ and Polnt of Connection, Water euppl::J ehall be extended ll!l shown from water suppl!:J 3.04 FIELD QUALITY CONTROL 2. Connect remote control valves to controller ln numerical se9uence ae ehown on Drawrnge. 3. Flnal location of controller shall be approved b!:J Landscllpe Archftect prior to lnstallatlon. 4. E:ach controller &ha II have a dedicated :;,eparate ground wire and ground!r,g as:;,embl!:J. Groundrng ae.sembl::J :;,hall be tested and shall measure 1@ ohms or lees Tn Impedance to be acceptable. Submlt results of te&t ln writing to owner. 5. Above ground condult ehllll be rigid galvanized with approprlate fittings. Below ground condult shall b<S? e,cheduie 41Z' PVC. 6. Label each field controller with letter designation (lndlcated on construction drawings) b!:J etamplng Tnto concrete pad when pad Ts poured ue1n9 branding Tron letters. E. Electrlc Control Valves, lnetllll top of cross handle a maximum of 3 Inches below flnlehed grade where shown on Drawings and as detalled. When grouped together, allow mlnlmum of 12 lnchee, between valve box sldee. lnetall each remote control valve in a &eparate valve box. ln&tall valve box flush with grade. When parall<S?I to roadwa~, eldewalk or other permanent element or etructure, control valve and box to be Tnetalled perpendicular to element or structure, spaced e9uall!:J-Space control valve& accordlngl::i-- 1. Connect valve wirlng to control llnd common wlrln9 uelng the waterproof" t::1pe connectors &pec1f1ed herein. 2. Install a reclalmed water warning tag to valve e.tem as detailed for those S!:J&tems uerng reclaimed water. G. Qulck Coupllng Valves, Install 9ulck couplers on double swrn9-jolnt aeeemblTes of Schedule 80 PVC pipe flush to 19.rade. Angled nlpple relatlve to pressure euppl!:J llne ehall be no more than 45• and no Iese, than IIZ'". ,ne.tall 9u1ck cauplrn9 valves as detailed. Mue.t have non-potable cap (purple) for both potable and reclaimed &:!stems. K. Vil Ive eoxes. I. Install one valve box for each t:!pe of valve installed ll5 detailed. Valve box extensions are not acceptable except for master valves. Install gravel sump after compaction of trenches. Place final portlon of gravel Inside valve box after valve box Ts backfllled and compllcted. valve box to be supported b!:J gravel sump. No brlcl<. or wood supports are a I lowed. Va Ive boxes are not to be cut to accommodate valve aesembllee. A Flushing, After prp1ng, rlsers, ar,d valves are Tn place and connected, but prior to Tnetallatlon of e.prlnkler heads, 9u1ck coupler aesembllee, and hose va Ives, thoroughl::J flush plplng 5!:J&tem under full head of water pressure from dead end ffttrnge. Malntafn fluehTng for 5 m;nutes through furthermost valves. cap rleera llfter rluehlng. !3. Teetln9, Conduct tests 1n presence of Owner and Landscape Archltect. Arrange for presence of' Landscape Archltect 48 hours In advance of testing. 5uppl::J force pump and other test e9u1pment. L After bacl<.fTll1ng, and lnetallatlon of control vlllves, ,quick coupltng vlllves and drain valves, fill pressure suppl!:J llne wlth water, and pressurize to 4@ per over the deelgnated static prese,ure or 120 per, 1.1;hlchever 1& greater, for a period of 2 hours. , _ , _ 2. Leakage, Preesure Loss, Test Te, acceptable if no leakage or ,oss of pressure 1s ev,dent during test period. 3. Leake, Detect llnd replllr leaks. 4. Retest s~stem until test pressure can be maintained for duration of tests. 5. Before flnal acceptance, pressure suppl~ llne shall remain under pressure for a period of 48 houre. C. Subetantral Completlon inspection. 1. Refer to 5ect!on @1200, Paragraph 1.e:11, for re9u1rements of 6ubetantlal Completion Tnspectlon &chedullng. 2. Entlre s~etem shall be complete!!:! Installed and operational prior to ecr,edullng of walk-through. 3. Operate each zone ln its entfret~ for Landscape Architect at tlme of' wa ll<.-through and, add1tlonall::J, open all valve boxes. _ 4. Owner's Repreeentlltfve and/or Landscape Archltect wTII generate a Punch Liet of ,teme to be corrected prior to f'lnal Completion. 5. f'urnleh materlale and perform Work re9uired to correct Tnade9uaclee of coverage due to dev1at1one from Contract Documents. 6. Dur1n9 walk-through, expose drip emitters under operations for observation b!:J Landscape Architect to demonstrate that i.he!:J are performtn9 and inetal!ed ae; designed:!: prior to placing of mulch material. Schedule separate walk-through 1f neceeear!:J, 2. Brand controller letter and station number on lid of each control valve box and drip tubing blow out etube. Brand 9ulck coupling valve box lids with letters "Q.C." Brand wire splice box llde wlth letters "W£>.". Brand gate valve boxes with letters "G.V.". Brand drain valve boxes with letters "D.V.". Letter and number e.Tze shall be no smaller than 1 Tnch and no greater Tn size than 1 112 Inches. Provide Sample top owner for approvll I. a. For reclaimed water s::1stems valve box cover shall be purple in color and shall be locked b!:J bolting tre cover to the box. 1.Contractor to submit completed project record drawrng information to Owner's Representatrve for approval &even da::J& prior to Substantial Completion wlllk-through. If record drawing Tnformatlon Te not complete, Subetllnt!al Complet!on wlllk-through will be postponed untTI all required Tnformatlon fa provldecL Refer to Paragraph 1.!Zl5A for record drawings re9uirements. D. Walk-Through for Final Completion. L Refer to Section @l2@1Z', Paragraph 1.01, for re9u1remente, of Flnal Completlon inspection scheduling. 2. Show evidence to Landscape Architect that Owner hae received accessorlee, charte, record drawings and e9u1pment llS re9u1red bef'ore Fina! Completion waik-t.hrough Te scheduled. 3. Operllte each zone 1n its entiret!:j for Owner's Representative and Landscape Archltect at time of walk-through to rns·ure correction of Punch List Items. 4. Contractor to obtain completed record drawings from Landscape Architect prlor to echedul1n9 wa lk-throu9h ror final completlon, and prepare controller drawings as re9u1red. Rerer to Paragraph 1.05.6. Controller drllwings re9u1rements. Present controller drawlnge, to Landscape Architect at final completlon walk-through. 3,05 ADJUSTING Upon comp let Ton of lnsta llllt!on, "fine-tune" entire s::1stem b~ re9ullltTn9 va Ives, adjusting patterns and break-up llrme, and setting pressure reducing valves at proper preeeure to provide optrmum and eff1c1ent coverage. Flush and adjust sprinkler heads for optlmum performance and to prevent overepra!:I onto walks, roadwa::1s, and bul)dTnge as much as possible. Heade of same t!:jpe e.hall be operating at same pressure A If rt Ts determined thllt Trrlgatlon adjustments wlll provfde proper and more ade9uate coverage, make such lldJusi.mente prior to Flna l Completion acceptance, as d!rected, at no addftTona I coet to Owner. Adjustments ma!:J a l&o include changes Tn no:z:zle eizes, degrees of arc, and =ntrol valve throttllng. B. Sprinkler heads shall be set perpendicular to f'lnlsh grade unless otherwise designated. c. Areas which do not conf'orm to dee.lgnllted operlltlon re9ulrement.e due to unauthorlzed changes or poor lnstlljllltlon practices shall be Tmmedllltel~ corrected at no addTtTonal cost to the Owner. END OF SECTION e:>28l1Z' AFA<DVED FOi'< 1-GATION AND PlA"ITl,;:s ONLY, INCLUDING Ff<l:C'eE lOCATION OF PLANTl,;:s A~A "AS BUILT" RCE___ EXP ___ _ REVIEWED BY: INSPECTOR DATE DATE LANDSCAPE ARdHITEdT OF WORK nRM: FiALPH STONE & ASSOCIATES l---+---1-----------+--+---+---t---J I S1HE6ET j CITY OF CARLSBAD ~2 !===='---'====P::::LA=N':::N=IN=G=D=E=P=AR=T=M=E=NT===:'...'.UL_j==:::::; 1---1----1----------------+---1!---t--,1 -1 IRRIGATION i3PECIF!dATIONS RALPH STONE & ASSOCIATES LANDSCAPE ARCJfITECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINJTAS, CALIFORNIA 92024 (858) 755-3188 Aqua Commercial Irrigation 810 Los Valocitos Blvd., SL1ile 204 San Marcos, California 92068 Ph, (760)750-1900 Fax: 1760)750-1999 ffCI !1-r;g1;rinr, D€csi.,;,11, 1~J,m1,h'•£ t~ W;_,teJ 'vl~r,;J(;.<''71E'"t ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: [NC!NITAS, CA 92024 TELEPHONE: (858) 755-3188 BY: -~~~=,-----DATE: ___ _ RALPH STONE R.L.A. N0.:-.,1245,,,9'------------ REG!STRA TION EXP/RATION DA TE: _,.Ds.,,6'-'/1"'5 ___ _ 1---1--1-----------+---t----------t--i----i CT 02-17 SHELLEY PROPERTY "FAIR . 0 AKS VALLEY" APPROVED /1d::( lr ~IA PLANNING /i\ DA TE INlllAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DA TE 1N111AL OTHER APPROVAL CITY APPROVAL DVVN BY: ---1 CHKD BY; __ _ RVWD BY: PROJECT NO. CT 02-17 DRAWING NO. 4405L ,---------=----=-------====----:=-=----:=---==---=:---:::=-=-==---------------------------------------------------------------------------------·················------------------------, PLANTING LEGEND TREES -INTERNAL SLOPES AND RIGI-IT OF WAY (:iT11130L 130T AN I CAL NAME COMMON NAME SIZE QUANTITY ~ 13AUHINIA X 13LAKEANA HONG KONG ORCHID TREE 24' eox 20 0 JACARANDA MIM051FOLIA JACARANDA 24' 13OX 3<2) ~ WA5HINGTONIA R06U5TA MEXICAN FAN PALM 24' BOX 12 GROUND COVER -INTERNAL SLOPES AND RIGHT OF \VAY 5'1'11130L BOT AN I CAL NAME GAZANIA R. LEUCOLAENA WHITE COFROSMA X KIRKII CONVOLVULU5 MAURITANICUS MYOFOl'i:UM FARVIFOLIUM JUNIPERU& CONFERTU5 COMMON NAME: WHITE: TRAILiNG GAZANlA NCN GROUND MORNING, GLORY MYOPORUM TRAILING, JUNIPE:R SIZE FLATS <il 12' OC. I GAL @ 24' OC. l GAL <i 24' O.C. FLATS@ 12' OC. FLA TS <il 12' O.C. QUANTITY 71,665 SQ.FT SLOPE$ 10,6':IO 5aFT. R.O.UJ. 35,615 5QFT. 5LOPE5 ':150 SQ.FT. R.O.W. 1Z> SQFT. SLOPES 1,S5,Z, 5QFT. R.O .W. l,Z,2p7& SQFT. SLOPES 34,00ei SQFT. R.O.W. A MINIMUM OF 3' OF ORGANIC MULCH SHALL 65 ADDED IN NON-TURF PLANTING AREAS WITH 5LOPE5 LE&5 STEE:P Tl-!AN 3,1 TO COVER THE SOIL SURFACE COMPLETL Y. WHERE ADJACENT TO HAl-!D 5URl=ACE5 SUCH AS SIDEWALKS CURBS, OR DRIVES (WHl:RE FINISH GRAPE 51-!ALL BE I' BELOW THE TOP OF THE !-!ARD SURFACE), THE MULCH THICKNE56 MAY TAPER DOLL,N TO I' THICK. SLOPE:S 1,,,1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWING PLANTING ST ANDARD5, 1,i:>: ;g~t: ~g:E& A. / • REINFORCED STRAW MATTING, TO BE USED IN CONJUNCTION WITH C:IROUNP COVER ALONG SLOPES 3' OR HIGHER. ( SEE STANDARD" I) STANDARD "I-COVER CROP/REINFORCED 5TRAUJ MATTING, COVER CROP SHALL 13E A SEED MIX TYPICALLY MADE UF OF QUICK GEl'<:MINAT!NG AND FA5T COVERING GRASSES, CLOVE:R5, AND/ OR WILD 1=LOUJl=R6. 5U6MIT Tl-iE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP 5HALL BE APPLIED AT A RATE: AND MANNER SUFFICIENT TO PROVIDE 90% COVE~E WITHIN (30) PAYS. ~ ARBUTUS 'MARINA' 6TRAW6ERRY TREE 24' BOX '- 0 MAGNOLIA C:i. 'LITTLE: G!EM' DWARF MAGNOLIA 24' BOX 0 ERI060TRY A DEFLEXA BRONZI= LOQUA T 24' BOX ~ V QUERCUS AG!RIFOLIA COA5T LIVE: OAK 24' BOX ALNUS CORDATA ITALIAN ALDER 24' BOX ALL TREl=S PLANTED WITHIN&' OF PUBLIC 61DEWALK5 SHALL 61= IN5TALLED WITH ROOT BARRIER$ APPROVE:D 13Y THE CITY. 51 51 22 31 ALL TREE5 ARE TO BE LOCATED A MINIMUM OF 7' FROM UTILITY 60Xl=5, WATl=R METER5, 5EWER LINES, 6TRl=ET LIG!HT5, CURB INLET BOXES, FIRE HYDRANT5, AND DRAINLINE5. SHRUBS AND VINES -INTERNAL SLOPES AND RIGHT OF WAY 5'T"Ml30L BOT AN I CAL NAME COMMON NAME $1ZE QUANTITY Q MAYE ATTENUATA NCN 5 G!AL 34 © ARTEHl61A 'FOWi$ CA5TLE' NCN IGAL 6 !Si) KNIFHOFIA UVARIA RED HOT POKER 5 GAL 18 TREES, SHRUBS, AND GROUND COVER -EXTERNAL SLOPES 5Y"MBOL BOTANICAb NAME COMMON NAME • HETEROMELES ARBUTIFOL!A CERCOCA!'i:FU5 MINUTIFLORU5 CEANOTHU$ VERRUC05U5 ENCELIA CALIFORNICA MIHULU5 AURANTlACUS SAL VIA AFIANA TOYON MOUNTAIN MAHOGANY WART"f5TEH CEANOTHU5 COA&T SU'NFLOWER BUSH MONKEYFLOUJER WHITE 6ME 6'1'11BOL REERE5ENT5 A COMBINATION OF THE FOLLOWING HELIANTHEMUM 5COPARIUM 5UN ROSE: REINFORCED STRAW MATTING ( SE:E STANDARD" I) HYPROSEED MIX "2 -DESIL TING BASIN DE5CRIFTiON ANEMOF51S CALIFORNICA -YER6A MAN&A ARTEME51A DOUC:ILA51ANA • Ml.JC:iWORT E5CH5CHOLZIA CALIFORNICA -CALIFORNIA POPPY LUFINU$ SUCCULENTU6 -ARROYO LUPINE VULPIA MICROST ACHY5 -3 WEEK FESCUE: C::.UAR GUM -50[L 61NDINC:i AGENT MYCORRHIZA-INOCCULANT WOOD FIBER MULCH IRRIC::ATED HYDROSEEP MIX L65. / ACRE 3 LBS.IA 3 L65.IA 2 L65./A 4 L6S./A o LBS.IA 120 L65.IA 60 L6S.IA 2,00ei LBS.IA SIZE 5 GAL 5 G!AL I G!AL I GAL I C::AL !-!05EFOT fl> 18' O.C QUANTITY 74 256 5':19 531 173 60,':115 5QFT le;l,24& SQ.FT TYPE OF REINFORCED STRAW MATTING! SHALL BE AS AFPROVED BY THl= CITY AND STAKED TO THE SLOPE: AS RECOMMENDED BY THE MANUFACTURER. 13. STANDARD "2-C::.ROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL 6E PLANTED UJITH A GROUND COVER Ki"IOUN TO HAVE: EXCELLENT 5011.. BINDING CHARACTE!-!15TIC5 <PLANTED FROM A MINiMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULi.. COVE~E: WITHIN ONE YEAR). C. STANDARD *3-LOUJ SHRUBS LOUJ SPREADING WOODY SHRU65 <PLANTED FROM A MINIMUM OF 2-3/4 INCH LINE:R5) 5HALL COVER A MINIMUM OF 51:VENTY (10%) PERCENT OF THE 5LOPE FACE (AT MATURE SIZE). D. STANDARD 04-TREE& AND/OR 1-ARGE SHRUBS TREES AND /OR LAR6E SHRUf:36 SHALL BE (PLANTED FROM A MINIMUM OF I GALLON CONTAINERS) AT A MINIMUM RATE OF ONE (I) FER TWO HUNDRED (2eie,) SQUARE Fl=ET. 51-0FES 6d OR STEEPER AND, A. 3' OR LE55 iN VERTICAL HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT MINIMUM STANDARD *I 6. 3' TO e,• IN VERTICAL HEIGHT REQUIRE STANDARDS "I, "2 AND*;!. C. iN EXCE55 OF 8' VERTICAL HEIG!HT REQUl!'i:E 5TANDARD5 "I, "2, *3, AND •4. AREAS C::.RADED FLATTER THAN i:>d 1-!EQUIRE STANDARD •1 (COVER CROP) UJHEN THEY HAVE: ONE OR HORE OF THE FOLLOWING CONDITIONS, A. 5HEET GRADED FADS NOT SCHEDULED FOR IM~VEMENT5 WITHIN 6 MONTHS OF COMPLETION OF ROLlC:IH GRADINC::.. (IF THERE ARE PAD AREAS THAT ARE NOT SCHEDULED FOi-! IMPROVEMENTS WITHIN 6 MONTHS PLEASE PROVIDE TEMPORARY IRl'<:IGATION AND PLANTING AS REQJIREPJ 6. A POTENTIAL EROSION FR06LEM A5 DETERMINED BY THE CITY. C. IDENTIFIED 6Y THE CITY AS HIGHLY Vl516LE AREAS TO THE PUBLIC OR HAVE: SPECIAL CONDITIONS THAT WARRANT IMMEDIAT!:: TREATMENT. 5TRELITZIA REG!INAE 131RD OF PARADISE & GAL 27 H3 ._I_·•_,,_. ___,I ERIOGONUM FA&CICULATUM-CALIFORNIA BUCKWHEAT REINFORCl:D €>TRAW MATTING, ( 51:E STANDARD• 1) ROSEPOT e 24' O.C RHAMNU5 CALll=ORNICA 'MOUND 8AN 6RUNO' COFFEEBERRY [I] WE5TRINC:IIA FRUITIC05A ~ E5CALLONIA FRADESII HETEROMELE5 ARBUTIFOLIA RHU5 INTEG,RIFOLIA 0 SAL VIA LEUCANTHA ~ RAPHIOLEF15 INDICA 'SPRINGTIME' ~ Cl$TU$ 6K.ANBERGII @ FITTOSPORUM CRA651FOLIUM 8 PLUHBAG;O AURICULATA 0 RHAMNU5 CALIFORNICA 'EVE: CASE' 0 G;REVILLEA NOELLII l) • £ .. A COTONEA5TER HORIZONT ALI$ CleTU5 H'rl3RIDU5 BOUC:IAINVILLEA '$.D. !-!ED' MACFADYENA UNGUi5-CATI PARTHE:NOCl55U6 T!'i:ICU5FIDATA PENNl&ETUM RUBRUM FENN15ETUM ORIENTAL15 COAST R05EHARY E5CALLONIA TOYON LEMONADE BERRY MEXICAN 6U5H SAGE INPIAN HAWTHORN Cl8TU5 NCN FLUMBAC:10 COFFEE BERRY NCN ROCK COTONEA5TER WHITE ROCKR06E NCN CA T'5 CLAW VINE B05TON IVY 6ERKELEY SEDGE REP FOUNTAIN GRASS NCN 1 GAL & GAL 5 C::.AL & GAL SC:IAL I C:IAL I G!AL I G:!AL IGAL 1 G!AL I G!AL I GAL I GAL 1 G!AL &GAL &GAL 5 C::.AL I G!AL ,. 18' O.C. I GAL ,. .:Ii:>' O.C. I c::.AL "' 2 4' O .C. 34 ':10 14 l!':>3 121 3':12 &51 645 621 60 42 26 85 102 ':I &':I IS 4,170 SQ.FT IJ~6 e, 5Q.FT 1,020 SQ.FT •NATIVE:-PLANT MATERIAL AVAILABLE THROUGH RECON (61S) 423-2284. ============== 6' CONCRETE MOW CUR13 FENCING AND WALLS ae 11m ;:ii: illl ri~ W:, m~ :w1 ifilll ill 11\l i!!i 111 ORNAMENT AL IRON VIEW FENCE .'i:,'1'.!'1'i'.itlii!L'rrl111illll-lliili!ill!ll1tll!!lllt'ili!l!r4li-l!I WOOD PRIVACY FENCE NOTE, FOR OVE:RALL FENCING TYPES AND FENCING! DETAILS, 5EE SHEET LIi. FOR FENCING LOCATIONS, SEE FENCING DIMENSION FLANS, 5HEET5 Ll2 AND Ll3. RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFOru,..,'1A 92024 (858) 755-3188 LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: ENCINITAS CA 92024 TELEPHONE: (858) 755-3188 BY: --,,.,..,.,~==----DATE: ___ _ RALPH STONE R.LA. NO.: _,_1.,_,45"'9 _________ _ REGISTRATION EXP/RATION DA TE: _06~/~/5 ___ _ APP~ l'O,. F'LANTIN'5 AND ll'l.1'<15ATION Olj!, Y, .Ji""UJDINS PR!:eCISE LOGATION.OF.,:1,,,,,TINS Al'<EA ..... ·-----,.,--------,.-----1 "AS BUILT" RCE___ EXP ___ _ DATE REVIEWED BY: INSPECTOR DATE ~······ .. ·········l----l------------+--+--t---t----i LJTI CITYLAN~~ D~P~~l~~BAD I 5325 I DA 1E INl11AL ENGINEER Of WORK REVISION DESCRIPTION PLANTING LEGEND CT 02-17 SIIELLEY PROPERTY "FAIR OAKS VALLEY" + I G4 ','' .~01'~•~ .,__,....., ::,:. ::::::;::: >:,.-... , :-:-:,:., .w:.::.'.'.'C.' •:.-.",\ ;;:,• 'l,~, ,:',:• 'c'.:c~ "- } "'· "ii,A~PR!i'-:•\ -~· !M ~,:,~-• ~,J,"-" ' FOR PLANTING LEGEND, SEE SHEET L-0 1: ,e,,, I I I I &iGl-lT LINE ; b' CONCRETE I MOUJ CUR6 ----::l'lll\!jillil, co *''•; ' it ·.· 1// 6' CONCRETE MOU/ CURB Kl="YM.AF NORTl-l N_T.6. -i~' ., =::::•. \ic . ~ < • .• ··-~-·-· ... -•--s.•. •. -..... ,_~ ..... _.,_ .. ' ,,-,' -.•.'.:.· :,;,..~- •_;,_.:-. .· RALPH STONE & ASSOCIATES LANDSCAPE ARCJ JJTECTURE • PLANNING 13-15 Encinitas Blvd. #630 ENCJNIT AS, CALIFORNIA 92024 (858) 755-3188 b' CONCRETE MOUJ CUR6 ---~ 2/Z>' TRAIL EASEMENT 1-11 HI 0 LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOCIA1FS ADDRESS: 1345 ENCINITAS BLVD. 11630 CITY, ST,: ~£~N~C~/Nw/T~A,,,$~ . .><CnA_.9c.s2~0L~"4,.__ _____ _ TELEPHONE: ~(8~5=8~) ~7=55~-~3~18=8~------- BY: --=~=-----DATE: ____ _ RALPH STONE R.L.A. N0.:~1~4=59~----------- REGISTRA T/ON EXP/RAT/ON DA TE: ~0""6'""'/1=5 ___ _ NATIVE TRAIL BUILT" RC[ __ _ EXP ___ _ DATE REVIEWED BY: INSPECTOR DATE 1----+---+-----------+--t---t----t----i I S1HE8ET I CITY OF CARLSBAD ~2 PLANNING DEPARTMENT ~ :==:'...':::::========~===: 1 DATE INITIAL INITIA~ ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL ClTY APPROVAL PLANTING PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED PLANNING DATE OWN BY: __ _ CHKD BY: __ _ RYWD BY: PROJECT NO. CT 02-17 I DRAWING NO. 440-51 ·•·::::Ij ••:-:· ~~~ ::'.· (·... }} }!}::::::.:-;,;,:. FOR PLANTING LEGEND, SEE SHEET L-0 KEYMAF NORT!-! N.T.6. MATCHLINE -SEE SHEET L-3 ~ . '··, ... ,.,/ . "'~y\ ¾( GI ,, 0 RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 CITY, ST.: _LENr,JJC:.;/JINr,n/1,TA'\;Si,_, -1.C;tJA_.19~21!.02.,4L-_____ _ TELEPHONE: _u(8~5:e.,8)~7'-"5'.c'.5:::-3c.,1~88=-------- BY: -~-=:-=,;;;-;;=-----DAJE: ----RALPH STONE R.LA NO.:-1.1:i,45c!.'19c._ _________ _ REGISTRATION EXPIRATION DA 1£: _t.,012,,6lu1;,.5 ___ _ I \ / H3 .. I ' ' J I • I I ' { ' ' I / 1-13 H3 C NORTH --:; O 20 40 80 GRAPHIC SCALE 1 "=20' "AS BUILT" RCE __ _ EXP, ___ _ DATE REVIEWED BY: INSPECTOR DATE CITY OF CARLSBAD PLANNING DEPARTMENT WJ PLANTING PLAN CT 02-17 SHELLEY PROf,ERTY "FAIR OAKS VALLEY ~===E==f==================--i=-=-=-t=-=-+=-=-~!-=--~ IA _r_rR_ov-,-Eo---'h:_'.Z\~-L 4-~~-Jt __ 1-.PLANNING DATE DATE INl11AL DATE INITIAL DATE INl1lAL ENGINEER Of' WORK REVISION DESCRIPTION 01HER APPROVAL CITY APPROVAL OWN BY: CHKD BY: __ _ RVWD BY: PROJECT NO. DRAWING NO. CT 02-17 440-5L --~-\ /,<-/~ /, / ·' '/ , .:~7=~ ~\: ,P i// ' ;~;,:!/ ~~ '7,1';"~ I) ~ ,,'' ~ ' L§ d•,' / ~V . o,.i, :i17~ G4 ~ ' I :-;,, -.;,, , .,.;,, "t,((,((, , r·1 ' · G . r Ll~ fY # / ... ~"' ~ /// C:14 .. ;, p .,,,, 64 ....... y:,,:,, •J,':"js ' ~ ~ (:,,-2.,~, ~ .• '· / ,. t" '. ·.·",'·· ; s;::---,/ C:.4 C ~tt-~, I , K; • , · ·"'-'"-"· r I G4 \ 4 -, ' ~-', ·\... 1 .,,_ .. , . "' J . 7 '. ' ' ,v, .. ">~, ·.. 5i . ...,, . . i ,•, .'-., I ; \1'"~d':;ti0 / ;, ,>,_ Ji.• _,,-\ •.• '", 1 1 ·--,~";:{t J~, .,,,,, •-,;..• ,, ir ! ,_ 1··1· " •. ,, . • " ., \ '· ',, ;~); (, ''''~'I, '\~:\1,1');"",'C/',JS 1"'.~ , ,7''f/ "'?, ,,,_ _ _ •'I" . '" . 9 >. / ', ., . \. < j -... "'"'' ,, ., " ' <..<>),_ l\ 1-· ·-./ "·· ', ✓t--1 ,~;,,;·""' s!,~C/lf.'!,,I ,<:"'~ . , -' ,, ' ' '·.: '\\. ~-<• '-·., 't, -,~.r';,J.-·/ "~;,.,., . -' ,\, \:;\, 'J/~ . ; '-:7:;;;~~Q~~'$~ •·,',.,., • . I W,""'i., ",·. ' •, •, ''" - ·,-:1 \ '•,, .. '· ',, i •• ·...,. I ''" ,, I ' _. . • G4 C:.4 G4 1 •._, '-...._ : .Jl , . c:'l<::~t:7°:,"'jl<:-·· •' ~·:re V'.•{"f"i.' "~;,\;,~\·~-'-. \\ \ '·,, " ,:, ,, €>!GI-IT J./INE .r ;,-, : , ·*, E,:--;"""' •:,;_-t\'. t: .,<:' .. ~ .•. , ' ~-, / ' I A&"'-1 1-~~-ltr.:.,. \ \\_\, ' .. ',,/ ' ', I 'ft/ ""'"""-~:.·, .. "' . ~ • , ~ ,,._ '-., ,,,.,_R V -· .. ,-..,, ,-·,.__, ' :1:-1\ ,'' ..,,is;-'~-,," ~>, ... ~v·,..,_ --·"'<'---·•o:-J '··, ·,., I<.:> "~~" .,,,,..,. f--i,,,..·°',·-~",; -~ ~ '; _:~-, ','\., V:.:l'J'"". ,,.,,a,,. ~'::-,... ·--,. . /· ) . ..,_ ·,.) .,. -r),_., ,.;,,. ,, . , ·,..,.. 1,~ ', /\1'/ ,,,,., •. /, .,,, ~-r,J,. •, .. • ' ' "·, 1 ,,, ., "·-i 4 I '. ·•• ·,(,\/;:'41,,~~W'~J\'-, '}:,;.,, , "'· ·k::, "4~l"'l~f:;: C:; lD GI FOR ' ' '-. "-:~ii;;;:~ 1'.'.; ,0Jt; ,., ,, ...;. ~-, , v . '1 ... '\/ .. '•\7\,' A -" , .,:t"_ . , ~ ~: r"""'-c, ' ' • • . · ••~·,n'ic, fr" Cc ,¾. ~2 ,1' •• -" \\ I -c. '·,;,, '•' '\"7\• ,, ~ ,', ; t•1}<n1~:t-i~ ' "C,,, <.,;> ' ·. , ",.,.ONE '-,::,,,: · ',, CK• ., ., , .. ,. -., ., / . ·• =•510~, A· ' , "-"· ·y Ki '-"·S ,., .,,. ,,. .,,'.,;,,~,. ·'• ,, 1 IRE 6Uf'f',...,._"<'. 101!,GZONE . ·"-".._,.., 64= ,.,., '\,'7\, • ,.,,,,,_ . ,/ ··-~fZ)~:-,{J.R<(jSHb~~~~1bl-iZoNE A-:3 1•,-~ ,_, !.:.1.'::/ ··,,i,~.Y ¥-.J:.'\.y. • ~ {\~i-~~~~'.':-~¾ ;'/ ._ t::> C.~I --.__ i-i;:;./ /~ ., ~·=· '/' -,,,,:. ·,,_ .; ',•, ,,,,, V, '·' '""~ I , ~ ~~~S;~~~::;;:-_..J\--" "' c:1,..,. "' -•, -.... A 1 -.,, ~-~ -• ,,-,, 1 -~·",,, ,t,. '"-"'-cc".'".;;,,, ,<~·,,,. . , , , • ; ,, ", ·, .... ,,,,."C,,· ' • .. ........ , -11 '., ~' ' '". I '<.>J,,_Jj~~•~t~ij ., . ._,," _,,. ''''"--~ , '· , ,-· • ....,~,1~:1v . •',!-•,, ""->-:, .... "',· ,, • • ,, • .. " • • -~".,_...,..,-..,<Ji;,~ ,_ ' ', ' , "·':$;,/ ,j, ',,_ -,,-r,,., ' . ,' .. ·<:c; ' ,'• '' '< ''"'-'<, • ' "-.. "-._ J ",~"J ~!,, .,f,1'-!CI•" ''-. ~ c• :J<,,,,','"· h"< C\i-,,t 1///:,)~;.-1 -,, ' , _,,~ [' \ -. ~,, I', >L ,,_;-, ..._ ~--.. , -._ '"'-• ~ ... ~ J .,,, ~1 "• K;' k"' '' '¥ /' "' •· ' \[<S' ' -----~'..,, ,._4 ,,.,/ ',,, '\~.,,, ~---.., ''--~"~"' •·u .. ,"'>'! .,_,~\""-,? \/c,._,;,_· ',,,.,.,/, '.{~;,,.~i-;/,y,_;s;.,75,),:.,.,,:;,:,k;;':-,,. .. ,, "'-.. :.::~:: .. "'rrr.. ,ls:", -...._ .,_,, "-,. 7, , . 0 •, , .. 0 . ,. ',eks • .,. ,, I , . ,., < '·' ' "/ '-..,, l ,, ' ' ,.__ J ._.,-'-II, -,, J. ,\Y: I\ c;H · ' ,J •l '\'. 'I /<''--, '--.... C ', foj ",.::::<! -·1.,1,,. .. "::'"'1·, .. ,:., , 'k '·, -l-;,;,r-.,·ic-f:)t, ,~ , .. ?··1?-'\7 ,it;,,·,,;;; -6-:,,. :""0-» ... • / -Jt (l ,,, ' O """1'1''-'•• ., < • . ·, . i\*,'t ,. ' · · '',' tr!' A a,,,, ·2--· >< ,, v ~ ~'<}-:. ... , I -<J]::~~~ ···.,~ ·"' .. :·'riJ.''.l: . '., .. ,~f:" -j·e.~· st\ .... \1 11 n-:, GR 00 / .. • ' .... ' ' ''"'' .,..,_, .. · .. · ',i, -~ . ''-, .. ;,;,</'• E ·-..... ,, >' 9 . Z ....... I -1.\ "·. ,_ .. ,.,,.. s / .. .. " ,,. "•. ...,__ ' . : ''t,;.~,; , ,v~, . ./l s......, J /' A"-,"" ,,, ,... ., JIii . - ,..~ ·ss r·,, , 0 --.. , .. , L A.1' = .. 0-. ... ,, "·, (,/,/ ' •!!!1"7 "-,...... 7'/ (.-";• ~ 9 .. _ ·-,, ~c •~-,, ---.:., /, ...... ..,_ ...... / ...... LANDSCAPE ARCHITECT OF WORK RALPH ST£T~~ & ASSQCJRE•PLANNING AROlllECT 630 LANDSC1;.~!s Encinitas BlOvRNd. #IA 92024 S CALIF ENCINJT ~58) 755-3188 & ASSOCIATE FIRM: R 1345 ENCINITAS BL VD. ADDRESS: 20 CITY, ST.: N 30 TELEPHONE: (858) 755-3188 BY: RALPH STONE DAT£: SEE SHEET L-0 PLANTiNG LEGEND, L A NO.: 145/1 R. . . OAT£· DATE INITiA REG/S1RA TION EXP/RATION . 06,/15 ENGlf>IEER OF WORK l() ~ F~ lN :-1,..vo~ IRRIGATIO~, iiLANTIN6 LO.:.ATION DA TE INITIAL ESCRIPTION REVISION D ' OTHER APPROVAL DATE KEYMAF N µ N.T.6_ INITIAL - NORTH O 20 40 l GRAPHIC SCALE 1"=20' "AS BUILT " RCE EXP DATE REVIEWE D BY: -3 INSPECTOR DATE um CARLSBAD DEPARTMENT ls325 1 PLANTING PLAN SHELLEY PROPERTY CT o~FliR, OAKS VALLEY" APPROVED PLANNING \ I ..., IS\ 1;-tt-: I .... S,:,' 10:S '::i.'. D A TE PROJECT NO. CITY APPROVAL OWN BY: -I CHKD BY:_ _ RVWD BY: CT 02-17 I DRAWING NO. _440-51 FOR PLANTING LEGEND, SEE SHEET L-0 KEYMAF NORTl-1 N.T.6. 616:HT LINE ,, ' : \,;, ~~ ,, '•, <·>:'•, RALPH STONE & ASSOCIATES LANDSCAPE ARCH.ITUCTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 . .-ilL.. . , • ., I ''-'4' fl"i ;-,·' GI .. \;.i 't ~ .. ·-· ---·-c;T~ ----~ --o o= --~2.-.-.. -~ -_, . •:--;»-. ·,~ .. :--,-~ .• _\ -• ",~,., r \_\ ., , ,•2.;>;;,?,~, • •-:f~~~ , ;,7,-,"'•. ,. I , -,, . _,X.,;,{'\;/)-1,~1)'1·---.. ~-----s•" "" ,~/ yr~".\'t.';f.W.,.R•• ;:• -:;:-A . ,\<~, r-. ', .• ·-·""Y.7,i·•--.-.. ·----~--" ':.~·',!;,i,i.,,¼,,ll '., -' €>' CONCRET GI MOW CURB GI- ' Gl' I i ,-✓- v' . ~~.:...:,·i?'· "'1( >· '·,<'"'-:-, . ' .,,,. ' >, I ~'~,,... '' ,1<,,,:·) '~,, '.X 'I / I I It) J 1-w w :z: tn w w tn I w z -...I :z: CJ ~ :E 0 z -2 cc (.) APf'ROVEt:) FO" PLANTIN9 ANO IAAIGA-rlON ONLY,J~J..I/DIN9 F'!'<EaCISE l-OC-ATION OF f'L<"NTINI> AREA NORTH -0 20 40 80 GRAPHIC SCALE 1"=20' "AS BUILT" RCE __ _ EXP.____ DATE REVIEWED BY: L-4 INSPECTOR DATE LANDSCAPE ARCHITECT OF WORK nRM: RALPH SWNE & ASSOC/A TES f----+---+--------+---1---+--1-----1~1 CITY OF CARLSBAD ~2 L£Lj~===--'===:P::::lA::::::NN:::l::::NG:::::D::E:::P:::AR::T:::M:::::E::::NT:::::==:::'...'::L.2£j::=::::::~ ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: __,_E",.,,NC.,.1,.,,Nlu.LaA s .... _C"'A"--"9.,,20~2~4c.__ _____ _ TELEPHONE: ~{8=5=8)~75=5~-~3~18=8'--------- BY: _________ DATE: RALPH STONE R.L.A. N0.:--'1"""45"-'9'-------------DA TE INITIAL DATE INITJAL REGISTRA TION EXP/RATION DA TE: -"'06"-/'-'-1.,_5 ___ _ ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL DATE INITIAL CITY APPROVAL PLAN'l'ING PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" PLANNING DATE DWN BY: PROJECT NO, DRAWING NO. CHKD BY: __ _ RVWD BY: CT 02-17 440-51 ~ t-i.LI LLI X ,n LLI LLI ,n I LLI z 31 \ I I G4 I lf"t;c;,''ft -:-:i~ G2 FOR PLANTING LEGEND, SEE SHEET L·-0 MATCffllNE -see SHEET L-a • ~-~-.... --~--------·--·=----,._'\-'"--'-'"--'-'-Tr's-\i:' 4 51 G4 z co I ..I 1-w w :c ,n w w ,n I w z -..I :c u = :E RALPH STONE & ASSOCIATES LANDSCAPE ARCHJTECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOCIATES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS. CA 92024 7£LEPHONE: (858) 755-3188 BY: _________ DA 7£: RALPH STONE: R.L.A. N0.:__,_1..c45""9'------------- REGISTRA TION £XPIRA TION DA TE:: _.u0,,,6 /ul,.,5 ___ _ I Al"l'ROVl=l:> FOR F'I.A>ITINe AND IRRIGATION Oljb Y, INCUJDIN& PRECISES l.OC-ATION OF ,..,_,..NTIN& AREA .. )}'.{:? '.~ KEYMAF NORTH -~ 0 20 40 80 GRAPHIC SCALE 1"=20' "AS BUILT" RCE ___ _ EXP-----DATE REVIEWED BY: INSPECTOR DATE , ---+--+-----------+--+----t---+---! ~2 CITY OF CARLSBAD I S3HE2ETS I ,-:=~==:::'...':==::::::PLA:::::N::N::IN:::G=D:::E::P=A::RT::M:::E::N::T===::..=::=~ PLANTING PLAN DA TE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION 01HER APPROVAL CITY APPROVAL CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED • / I ·U.. )";A &f, ~-eTI PLANNiNG DWN BY; PROJECT NO. DRAWING NO. CHKD BY: __ _ RVWD BY: CT 02-17 440-5L \ \ FOR PLANTING LEGEND, SEE SHEET L-0 KEYMAF NORTl-l N.T.S. 2@' TRAIL EASEMENT -j----· IIZ>IZ>' SDGE EASEMENT SEE SHEET Ll4 RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LANDSCAPE ARCHITECT OF WORK FIRM: RAl PH STONE & ASSOCIATES ADDRESS: 1345 ENCINITAS BL VD. #630 CITY, ST.: (NCINITAS. CA 92024 TELEPHONE: (858) 755-3188 BY: -~=~=~----DATE: ___ _ RALPH STONE R.L.A. N0.:~1~4~5~9 ___________ _ REGISTRATION EXP/RATION DA TE: ~0=6.,_/~15~---- APPF<OYEO FOR PLANTINo. ANO IRR!5ATION 011/,,'<', INcLIJDINe PRECISE LOCATION Q!' .-w,,NTIN<!! AREA L-6 co _j tu LLI :c en LLI LLI en I LLI z -..I :c u ~ :E NORTH ''AS BUlLT" RCE __ _ EXP. ___ _ REVIEWED BY: INSPECTOR DATE DATE ~ CITY OF CARLSBAD ~ l---l--+----------------+--t---t---t--7 Lflj PLANNING DEPARTMENT Ll£_j :==='._:=========~~===; l---+--1--------····················------+----+--t----+--i DA TE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL PLANTING PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED I C:r-~l-??it I?• ~-1'? PLANNING DATE DWN BY: PROJECT NO. DRAWING NO. CHKD BY: CT 02-17 440-51 RVWD BY: ::.~:-:•:::.. ··. FOR PLANTING LEGEND, SEE SHEET L-0 KE1MAF NORTH N.T.S. C:12 .. ' .. ---=w 1 . ,·· j -Pt ·_ :~;., . -~---.. -.. • fl RM: RALPH STONE & ASSOC/A JES ADDRESS: 1345 ENCINl'fAS BL VD. #§30 CITY, ST.: ENCINITAS. CA 92024- TELEPHONE: (85B) 755-3188 BY: -==:--;,=:::------DA TE: ____ _ RALPH STONE RL.A. NO.:_ic:,4:,,5,,_9 ___________ _ REGISTRATION EXP/RAT/ON DA TE: ~0""'6/~t-5 ___ _ DATI: INITIAL ENGINEER Of WORK H.3 1 DATI: INITIAL REVISION DESCRIPTION OTHER APPROVAL DATI: INITIAL CITY APPROVAL , rJ NORTH 0 20 40 80 GRAPHIC SCALE 1 "=20' "AS BUILT" RCE __ _ EXP----DATE REVIEWED BY: CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" PLANNING DATE DWN BY: CHKD BY: __ _ RVWD BY: PROJECT NO. CT 02-17 I DRAWING NO. 440-5L FOR PLANTING LEGEND, SEE SHEET L-0 NORTH N.T.S. "" ' '"' ,' '·, , / '; \i --~ \, \0..,. '", {:, / C;i4 ·"'·, *" .,/,,:. ' ,''1} • a • , / 20' FIRE SUFFRE5510N ZONE A-I 20' FIRE 5UFFRESSION ZONE A-2 <" 20' FIRE 5UFFRE5SION ZONE B-3-SEE NOTE• \,\ ' \ ' ' I / / ' ' I ! ' , •ZONE B-3 fNDICATE5 SELECTIVE FRUNING OF 40% OF THE MODERATE FUEL 5FECIE5 VOLUME AND l01Z>% REMOVAL OF HIGH FUEL 5FECIE5 PER CITY OF CARLSBAD ANY FUTURE BRUSH MANAGEMENT WITHIN FIRE 6UFPRE5510N ZONE 3 OF OPEN SPACE LOT 12 SHALL BE DONE WITHOUT Dl6TURBINGi THE GROUND AND SHALL REQUIRE A BIOLOGICAL MONITOR. ACTIVITIES IN THE FROXIMITY TO THE SAN DIEGO GOLDENST AR 6HALL OCCUR BETWEEN JULY I AND NOVEMBER 30, WHEN THE PLANT 15 NOT EXPECTED TO HAVE FOLIAGE ABOVE THE GROUND AND NO HEAVY EQUIPMENT WILL !3E USED THAT MAY COMPACT THE SOIL. I 30' OMWD EASEMENT SEE SHEET Lll4 I \ \ \ \ \ \ I \ \ I \ ~V'eD FOR Pl,.ANTIN9 ANO :!<!<15ATION Oljb '1', INCLUPIN5 F'l'<ECISE LOCATION OF ~=NTIN5 - \ \ \ \ I I \ \ \ \ ' ' I \ \ \ I ! I I \ I \ I I \ ' \ ,/ ~ NORTH ' \ I I .,,. ~ 0 20 40 80 --GRAPHIC SCALE i "=20' "AS BUILT" RCE __ _ EXP.,----DATE REVIEWED BY: INSPECTOR DATE LANDSCAPE ARCHITECT OF WORK ~ CITY OF CARLSBAD ~ ~--1---+---------------+------,c----t--~r-------J ~ PLANNING DEPARTMENT L.2£j ~~~==================-'==='==; RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd, #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 FIRM: RALPII STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BL VD. #{JJO CITY, ST.: ENCINITAS. CA 92024 TELEPHONE: (858) 755-3188 BY: --,;;-:-,-:,:,,,-=:=----DATE: ___ _ RALPH STONE RLA, NO.: __,1,:c45,e,9,__ _________ _ REGISTRA noN EXP/RATION DA TE: ~9.;6,-,/1=5 ___ _ f-----l--·---··--------------------------1----+--+---t---i 1 DA TE INITIAL DA TE INITIAL DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL PLANTING PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" PLANNING DATE DWN BY: ---PROJECT NO. DRAWING NO. CHKO BY: __ _ RVWD BY: CT 02-17 440-51 I I I \ ' I_ FOR PLANTING LEGEND, SEE SHEET L-0 I I I I .,-MATCHLINE .. SEE SHEET L .. 8 •ZONE 6-3 INDICATES SELECTIVE FRUNING Of 40% OF THE MODERATE FUEL-~~~- AND 100% REMOVAL OF HIGH FUEL SPECIES FER CITY OF CARLS!3AD ANY FUTURE !3RUSH MANAGEMENT WITHIN FIRE SUPPRESSION E33 OF OPEN SPACE LOT 12 SI-IALL 13E DONE WIITHOUT DI5TUR!3ING THE GROUND AND SHALL REQUIRE A 6IOLOGICAL MONITOR. ACTIVITIES IN THE PROXIMITY TO ll-lE SAN D !EGO GOLDENST AR SHALL OCCUR BETWEEN JULY I AND NOVEMBER 30, WHEN THE PLANT IS NOT EXPECTED TO HAVE FOLIAGE ABOVE THE GROUND AND NO HEAVY EQUIPMENT WILL BE USED TI-IAT MAY COMPACT THE SOIL LOT 52-MODIFIED FIRE SUPPRESSION ZONES-SEE NOTES SHT. 21 I \ \ I ' '1 \ \ \ \ \ RCE __ _ REVIEWED BY: I 0' SDGE EASEMENT SEE SHEET L 14 -20' TRAIL EASEMENT SE,E SHEET 1...14 EXP ____ _ DATE SHELLEY PROPERTY 0 AKS VALLEY" DATE PROJECT ~10. DRAWING NO. CT 02-17 440-51 L() I n I OJ 1--w en z 0 f-u => 0:::: I--en z 0 u 0 w en > w 0:::: I ,. ' ' if II ;i LANDSCAPE CONSTRUCTION 5COFE: OF WORK Ti-IE U:ORK Si-lALL CONSIST OF THE FURNISI-IING OF ALL LABOR, TOOLS, MATERIALS, PERMIT&, AFFLIANCE5, TAXES AND ALL OTI-IER COSTS NECESSARY FOR THE PLANTING AND INSTALLATION OF ALL CONSTRUCTION E:LEMENTS IN AN ACCEPTA!3LE OPERATIONAL CONDITIOl'-l A& i-lEREIN SPECIFIED AND SI-IOWN ON Ti-IE ACCOMPANYING! DRAWING!&. FLANT5 (I) TREES, 51-1RLIE35, VINES, AND GoROUND COVERS 51-iALL !3E FURNl5!-IED ElY Tl-IE CONTRACTOR AS Ll5Tl:aD ON Ti-IE DRAWING!& AND HEREIN SPECIFIED, ALL QUANTITIES AND 5IZE5 !~ISTED ARE THE MINIMUM ACCEFTA,BU':. UNDER NO CIRCUMSTANCES 6!-IALL THERE 6E ANY SLIB5TITUTION5 OF FL.ANTS, QUANTITIE':S OR SIZES FOR Ti-lOSE LISTED ON Ti-IE DRAWING& EXCEPT WIT!-1 THE E':XFRE55 WRITTE:N CONSE:NT OF THE LANDSCAPE ARCI-IITECT. (2! FLANTS SHALL BE i-llGH QUALITY EXAMPLES OF Ti-lEIR SPECIES OR VARIETIES, Will-I WELL-Dl:VELOPl:D 13RANCI-IING, 5YSTEM5 AND VIGOROUS ROOT SYSTEMS. PLANTS SHALL 61: FREE OF KINKED, CIRCLING OR GIRDLING ROOTS. Tf-lE AeovE CONDITION MAY CAUSE PLANH'> TO ee: REJECTeD AT ANY TIME, ALL PLANTS SHALL 6E PROPERLY 'HARDENED OFF' IN CONTAINERS 13EFORE Fl ANTING, (3) ALL PLANT MATERIAL. SHALL Meer Ti-IE SPECIFICATIONS OF FEPE!-<AL, STATE AND COUNTY LAWS REQUIRING INSPECTION FOR PLANT DISEASES, 13E FRl::E OF INSECT INFl:::5TATION AND THEIR EG!GS AND HAVE A HEALTHY ROOT SYSTEM FREE OF DISEASE. < 4) ALL PLANTS 51-lALL 13E TRUE TO hlAME AND SIZE IN ACCORDANCE WITi-1 THE STANDARDS AND PRACTICES RECOMMENDED BY THE AMERICAN ASSOCIATION OF NURSERYMEN. (':>! ROOT--ISOUND PLANT MATERIAL WILL NOT BE ACCEPTED. THE LANDSCAPE ARCI-IITECT RESERVES Ti-IE RIGHT TO Rl:aJECT THE COMPLETE LOT OF ANY SF!=CIE5 FOUND TO BF ROOT-60UND. THE CONTRACTOR SHALL Ti-lEN FURNISH NEW MATERIAL POR EXAMINATION, PLANTING TREES AND 5i-lRLIB5 (I) FLANT MATERIAL 15 5U13JECT TO Ti-IE APPROVAL OF THE LANDSCAPE ARCI-IITECT 6EFORE PLANTING 15 STARTED, (2) FLAG OR STAKE ALL TREE AND 5i-lRU6 LOCATIONS AND IDENTIFY THEM BY SPECIES FOR APPROVAL 13Y LANDSCAPE ARCHITECT PRIOR TO 5T ART ING ANY EXCAVATION, (3! EXCAVATE FLANTINCo HOLES WITH VERTICAL SIDE:5 TWO TIME5 THE WIDTH OF Ti-IE CONT AINE'R (4) SET PLANTS IN THE CENTER OF THE PLANTING HOLi=, IN Vl=RTICAL POSITION, 50 Ti-lAT THE CROWN OF THE ROOTBALL WILL BE A MINIMUM OF I INCi-i ABOVE Ti-IE SURROUNDING GRADE. OJ IMPORTED TOP SOIL, IF REQLIIRED, SHALL 13E SANDY LOAM, FREE OF WEEPS, WEED SEEDS AND ROCKS OR DEBRIS OVER 3/4 INCHES IN DIAMETER ll"IPORTED TOPSOIL SHALL BE Ti-lOROUG!HL Y INCORPORATED INTO EXISTING! SOIL 13Y TILLING A MINIMUM OF 6 INCHES DEEP BEFORE ADDING! SOIL AMENPMENT5. ( 4) UNIFORMLY SPREAD THE FOLLOW INC. MATERIALS Ar THE AMOUNT GIVEN FER l,00C> SQUARE i"EET, -ORGANIC SOIL AMENDMENT 4 CUBIC YARDS -AGoRICUL TURAL GYPSUM 200 FOUND& -SOIL SULFI-IUR I!:? FOUNDS -FERTILIZER lb-10-I0 2!'> FOUNDS (S) THOROUGol-lL Y AND UNIFORMLY ROTOTILL ALL MATERIALS TO A DEPTH OF b INCi-iE&, (b) UPON COMPLETION OF PLANTING OPeRATIONS, MULCH GROUND COVER AREAS WITi-1 REDWOOD 13ARK AT Ti-IE RA.Tia OF;;, CU6IC YARDS PER 1,000 SQUARE FEET. SOIL PREPARATION FOR Si-lRU65 AND TREE5 (I) PRIOR TO THE START OF PLANTING OPERATION, DIC. A I FOOT SQUARE 6Y I FOOT PEEP HOLE IN SIX SePARATE LOCATIONS AROUND Ti-IE SITE. FILL THE EXCAVATED HOLES COMPLETELY WITH WATER. AFTER WATER COMPLETELY DRAIN5, FILL THE i-lOLE5 Aei,AIN WITH WATER. DO NOT PLANT IF SOIL 15 IN A MUDDY CONDITION. NOTE, IF THE HOLE DOES NOT COMPLETELY DRAIN IN 24 i-lOUR5, CONTACT Ti-IE LANDSCAPE ARCHITECT IMMEDIATl=L Y. (2! PLANT BACKFILL Si-lALL CONSIST OF Ti-IE FOLLOWING MIXTURE, -SITE SOIL -ACID IRON Fl.LIS -COl"IMERCIAL FERTILIZER (3) PLANT TABLETS, TREES/51-lRUBS -SPECIMEN TREES <FOR EACH 1/,' CALIPER MeA5UREP 14' AElOVE SOIL LEVEL! 15 GALLON TREE& -!, GALLON TREES/SHRUS5 -I GAL.LON &HRLIE3S C.ROUND COVERS -b INCH FOT -4 INCH POT IClCl % 2 L135./C.Y. 13ACl<FILL MIX 2 LJ:35,/C,Y, 6ACKFILL MIX NO. OF PLANT TABLETS REQUIRED 4 -21 GoRAM b .. 21 GRAM 3 -21 GRAM I .. 21 C.RAM I-!'>GRAM S!-lALL BE GRAPED TO A MAXIMUM Id SLOPE AND PROVIDED REINFORCED STRAW MAT ON THE TOF OF 5LOFE RUSSER TREE TIES LOOPED IN A Fie.URE 8 AROUND TRUNK AND 5TAKE EACH TREE TIE SHALL 6E NAILED TO &TAKE USINc. GALVANIZED NAl1-5 LODGEPOLE 5T AKE 2' DIA. 6' FROM LOWEST 6RANCH CHAMFER AS NEEDED TO ELIMINATE 501 5LOLIGHINc. PLAN DO NOT REMOVE 5IDI= GROWTH ALONC. TRUNK. PRUNE TO REDUCE CROl1N UJEIGI-IT AS DIRECTED BY AGENCY .. (2! 2' PIA LODGEPOLE 5TAKE5 AND 4 TIES. TOP TREE TIEo 5i-lALL E3E 6' AElOVE BENDING! MOVEMENT OF TREE, TIES SHO PROVIDE FLEXIEllLITY OF TRUNK ElUT NOT ALLOW RUBBING OF TRUNK AGAINST STAK!". cur STAKE& Off 6' ABOVE TIES TOP OF 15AL.I-I' AElOVE FINloHED GRADE ~ ...... 1-2' MULCH ----------.... ----......._-......__ LANT , '=#=='FbA.6LETS 3' CLEAR FROM TRUNK ------------------------~=----...._ 4' !-l1Gii-l 13ERM ~;-------------=-=====-~ -........~::;~ FIRMLY COMPACTED "' ER SPEC AX. 3 1 EEF 6' MIN. DEPTH OF ROOTBA,LL 24' PLANT T AElL.ET5 FER 5FEC5 MAX. 3' DEEP I ~-PARCD """""' 2 x 13ALL. WIDTH SCARIFY BOTTOM AND MINIMUM EDGES OF FLANT PIT UNDISTURBl=D NATIVE SOIL SLOPES J 2 x BALL WIDTH MINIMUM LEVEL GROUND 24' -ALL TR!:-'1:5 PLANTED WITHIN!'>' OF FUBLIC 5IPEUJALK5 Sf<ALL BE INSTALLED WITH ROOT ElARRIER AFFROVED ElY THE CITY OR 2x ROOTBALL WIDTH MIN. ~--SET ROOTSALL I' ABOVE PINl5H GRADE INST ALL MULCH TO EDGE OF ROOTBALL -DO NOT INSTALL MULCH ON TOP OP ROOT13ALL ---BACKl=ILL AS SPECIFIED (E,J ALL 13ACKflLL MATERIALS A& SPECIFIED i-lEREIN SHALL 6E MIXED THOROUG!HL Y E:lEFORE USE. NO DtBRIS OR ROCK LARGER Ti-lAN 1-1/2 INCHES IN DIAMETER SHALL SE ALLOWED IN BACKFILL MIX. (OR SMALLER CONTAINER) -FER EAC!-1 CUTTING OF GROUND COVER I ~ !? C.RAM A TREE PLANT ING AND S T_A~K~IN~G~-------i ________ N_.T_._S. ____ ----i-6;;='.?=;S-:::=l--t=::Rr7UB~P~Lc:::;:;A=::::N-::::==-T I_N=::G::--:::::-::c==::::::-----N_.T_.S_.1 LOT 52 FUEL MODIFICATION ZONES -.._---~ (b) CAREFULLY SCARIFY OR LOOSEN SIDES OF EACf-1 ROOT 6AL.L. FRIOR TO PLANTING, SCARIFY SIDES OF !"LANTING HOLES BEFORE INSTALLING PLANTS. (7) 6ACKFILL Si-lALL 13!= IN5TALLl=D IN 1o INCH COMPACTED LlfT5. WATER PLANT IJJHEN BACKFILL OPERATION 15 I-IALF COMFL.ETED. ALLOW WATER TO DRAIN our SEFORE PROCEEDING WITH Ti-IE 13ALANCE OF THE 13ACKFILL .. (8J CONSTRUCT A COMPACTED 4 INCH HIGH WATER E:lASIN AS WIDE AS THE PLANTING! 1-lOLE AT EACH PLANT LOCATION, UFON COMFLl=TION OF IN5TA1-LATION, WATER Ti-lOROUGoHL Y, 6ACKFILI.ING ANY VOIDS WITH ADDITIONAL FREFARED SACKFILL (SJ ALL TIEINGo MATERIALS, MARKING! TAPES AND NURSERY STAKES ARE TO ElE REMOVED Al THE TIME OF PLANTING,. (IC>! TREES 24' SOX OR LARGER SHALL BE PLANTED FRIOR TO INSTALLATION OF LATERAL IRRIGATION LINE5, <:;ROUND COVERS (IJ SOIL f'REFARATION AND FINE GRADING! Si-lALL BE COMPLETED PRIOR TO GROUND COVl:,R PLANTING,, (2) ROOTED CUTTINGo5, PERENNIAL. GoROUNP COVER PLANTS OR ANNUALS Si-lALL NOT ElE ALLOWED TO DRY OUT 13EFORE OR DURIN<:; FLANTINC:, OPERATIONS. ROOTS SHALL SE KEPT MOIST SY MEANS OF WET SAWDUST, Fl=AT MOSS, OR BURLAP, OR LEFT IN FLATS AT ALL TIMES DURING PLANTING OPERATIONS. ROOTS Si-lALL NOT Ell= EXPOSED TO THE AIR EXCEPT WHILE ACTUALLY 13EING PLACED IN THI= C:,ROUND. WILTED PLANTS WILL NOT eE ACCEPTED. SOIL AMENDMENT ADJUSTMENTS <I! IT IS Ti-le RESFON&IBILITY OF THE CONTRACTOR TO CONDUCT SOIL TeSTING PRIOR TO AMeNDINei, OF SITE SOIL AND TO MAKE ADJUSTMENTS TO SOIL AMENDMENT& AfTER REVIEWING! TEST RESULTS WITH OWNER'S AUTI-IORIZED REPRESENTATIVE. (A! CONTRACTOR WILL FORWARD A COPY OF SOIL TEST RESULTS TO Ti-IE LANDSCAPe ARCHITECT FOR REVIEW. (!';,! ADJUSTMENTS TO 50IL AMENDl"IENT5 TO 13E MADE AFTER REVIEW OF TEST RESULTS WITi-1 OWNl=R'5 AUTI-IORIZED REPRE6ENTATlvE, (C) RESULTS AND RECOMMENDATION& OF Ti-IE SOIL Tl=STING LA60RATORY SHALL BE SU13MITTED TO AND APPROVED BY THE CITY, Ti-IE APPROVED RECOMMENDATIONS FOR AMENDMENTS AND BACKFILL SHALL 6E INCORPO!-<ATED INTO Ti-IE LANDSCAPE FLANS PRIOR TO THE ST ART OF CONSTRUCTION AND 51-lALL BECOME FART OF THE AFPROvED FLANS WEl=D REMOVAL WEEDS, INCLUDING BERMUDA GoRA56, AND THEIR ROOTS SHALL 6E DUG! OUT FROM ALL PLANTING AREAS AND REMOVED FROM if.IE SITE. Wi-lEN IT 15 NECl:::S5ARY TO CONTROL THE REGROIJJTi-1 OF THe5E PLANTS, THE CONTRACTOR 51-lALL APPL. Y ONE OR MORE TREATMENTS OF AN APPROPRIATE HERBICIDE PER MANUFACTURER'S DIRECTIONS REGARDING CONCENTRATION AND METHOD OF APPLICATION, AN AMPLE PERIOD OF TIME SHALL BE ALLOWED FOR EFfECTIVE CONTROL PRIOR TO REMOVAL, SOIL FRe:FARATION AND PLANTING, GUARANTEE AND REPLACEMENT& (3! ALL AREAS Rl=CEIVINC. PLANTS S!-IALL BE MOIST TO A MINIMUM DEPTH OF SIX ALL 5i-lRUB5 AND c;ROUND COVERS 5i-lALL BE GUAJ-<ANTEED ElY Ti-le CONTRACTOR INCHEo AT Tll"IE OF Fl-.ANTING;. FOR PROPER GROWTH AND HEAL TH FOR A FERIOD OF NINETY ('2l0! DAYS AFTER (4! GROUND COVtR 51-lALL BE WATERED IMMEDIATELY AFTER PLANTING; AND COMPLETION OF THE SPECIFIED MAINTENANCE FERIOD AND/OR FINAL, THOROUGI-ILY WATEl'<!:D AT Ti-IE END OF Ti-IE DAY OF INoTALLATION. ACCEPTANCE BY Ti-IE LANDSCAPE ARCHITECT. ALL TREE& AND FIELD QROWN SPECIMENS Si-lALL 6E GoUARANTEED !5Y THE CONTRACTOR TO LIVE AND GoROW IN PLANT PROTECTION AN ACCEFTAElLe UPRIGHT F05ITION FOR A PERIOD OF ONE YEAR AFTER (I) ALL PLANTS LA6ELED AS i=Xl5TING, PLANTS TO BE TRANSPLANTED, OR ANY COMPLETION OF THI= SPECIFIED MAINTENANCE PERIOD AND/OR FINAL OTHl=R FLANTS THE OWNER WISHES TO REMAIN SHALL ElE GolVEN UTMOST CARE ACCEFTANCE SY THE LANDSCAPE ARCHITECT, Wi-llCI-IEvER 15 T!-41= LAST TO AND PROTECTION. ANT PLANTS DESTROYED OR DAMAG!ED DUE TO OCCUR CONTRACTOR OPERATIONS SHALL BE REPLACED IN KIND AND &IZE, CLEAN-UP (2) THE QRADE WITI-IIN Ti-IE DRIP LINE OF ANY EXISTING TREE SHALL NOT 6E CLEAN UP ALL WORK AREAS PAIL Y. UPON COMPLETION OF WORK FOR THIS ALTERED IN ANY WAY WITHOUT FIRST OBTAINING APPROVAL AND SECTION, REMOVE ALL RUB6I5H, TRA51-1 AND DE13Rl5 RESULTING FROM RECOMM!;;NDATIONS IN WRITING FROM THE LANDSCAPE ARCI-IITECT. LANDSCAPE OFl=RATIONS FROM Ti-IE &ITE, REMOVE EQUIPMENT AND IMFLeMENT5 (3) ALL PLANTS ON SITE EiTHl=R IN THE G!ROUND OR IN A i-lOLDING AREA SHALL AND Ll=AvE ENTIRE AREA IN A NEAT AND ACCEFTA6LE CONDITION, SUCH AS TO 61= t"'IAINTAINED AND PROTs:CTED AT ALL TIMES 6EFORE AND DURING PLANTINC. ~1EET THE APPROVAL OF THE LANDSCAFE ARCHITECT, WITH ALL PAVING, WALKS SOIL AMENDMl=NTS AND OTI-IER CONSTRUCTED SURFACES FREE OF DIRT AND DEBRIS. MAINTENANCE (I) DESCRIPTION REDWOOD SAWDUST, MINIMUM b% NITROGEN flASED FLANT MAINTENANCE WORK SHALL CONSIST OF APPL YING WATER, FIR OR CEDAR SAWDUST, MINIMUM b% NITROC.s:N 6ASl:D WEEDING!, CULTIVATION, SPRAYING, PRUNING, EPGINC. AND MOWING! OF FIR OR PINE SARK, MINIMUM .8% NITROGEN BASED LAWNS, REPAIRING, REPLACEMENT OF PLANTo Ao NECESSARY TO ANY OR<:;ANIC SOIL AMENDMl=NT USED 5i-lALL ElE NITROGoEN 5TAEllLIZl:D, ACI-IIEVE E5TABLISHMENT AND HEALTHY GROWTH, AND PERFORMING A,LL FINAL PLANT E5TA6Ll5i-lMENT WORK (2) PARTICLE &IZl'c Tl-IE ENTIRE PROJECT 15 TO Ell: MAINTAINED FOR A PERIOD OF ':lS -IClCl% PASSING 0.3S MM STANDARD SIEVE NINETY (':10) CALENDAR DAY& COMMENCING FROM THE TIME ALL C Si-lALL 131= GRADED TO A MAXIMUM lei SLOFe AND PROVIDED REINFORCED 5TRAW MAT ON THE TOF OF SLOPE WATER TROUG!H 18' LONG ~---CENTERED ON 5i-lRU!3 AND PARALLEL TO SLOPE ~--SET ROOTSALL. I' ABOVE FINISH GRADE -,---INSTALL MULCH TO EDC.!': OF ROOTBALL -DO ~!OT INSTALL ON TOP OF ROOT13AL1- -{-2' EARTH 13ERM . . , ~ FINISH G!RADt SCARIFY SIDE OF PLANT FIT PLANTING T A13LET5 AS &FECIFIED S!--tRUB PLANTING ON SLOPE N.T.S. D BO -IC>C>% FA&SING 2,33 MM STANDARD SIEVE ITEMS OF WORK HAVE ElEEN COMPLETED TO THE SATISFACTION OF A5-!3UILT PLANS FOR ALL PROJECTS ARE REQUIRED TO 6E 5U13MITl=D. (3! SALINITY THE LANDSCAPE ARCHITECT, DURING! THIS MAINTENANCE PERIOD, 5UEll"IITAL OF AS-BUILT PLANS Si-lALL ElE AS REQUIRED BY Ti-IE SATURATION EXTRACT CONDUCTIVITY Si-lALL NOT TO EXCEED ;;,,!,, MILLI-OHMS Ti-IE CONTRACTOR SHA1-L MAKE A MINIMUt-'I OF TWO VISITS TO THE ENG!INEERING AND PLANNING DEPARTMENTS, Ti-IE FINAL PLANS -<----------FENCE OR WALL -<--------TRAIN VINe TO f'eNCE OR UJALL FOR CLIMEllNG A5 REQLIIRED FOR VINE' SIZE'. -<---------TIE VINE TO FENCE. ~-----PLANT UJIT!-l STEM AS CLOSE TO FENCE Ao F05Sl6LE, ---TOF OF ROOTSALL - I' A130VE FINISH GIRA.DE ~---INSTALL MULCH TO EDGE OF ROOT13ALL -PO Nor INSTALL MULCH ON TOF OF ROOTElALL r+-"~cl),\E~m t'INl5H GRADE fl!"fm----SCARIFT SIDES OF PLANT FIT l'G>,,Hf!fee----PLANTING! TA6LETS ·,-:'i '· •... . AS SPECIFIED · .. ·,: '": .. ,-~·<cffi§lll;--1 ---eACKFILL -AS oFeCIFIED "" = _1111"''111 ffi[IIII Ill lll/11111 1111 A5 SPEC'D V '-----VIN!:: ROOTl3ALL '-----EXloTINGi SUl:3C,RADE N.T,S. Modified Condition A -Lot 52 Fair Oaks/South€m Preserve ~ APN 2230615400 Address: 7530 CAMINO MINERO ~ Fuel modification zones for manufactured slopes abutting hazardous native vegetation. The following \, candiUans may apply: ZONEA-1 -Zone A-1 shall be measured horizontally 20 feet outward from a beginning location on the buildable pad area. • Planting within Zane A-1 shall consist of ground caver or law growing shrubs species (less than three i3) feet in height) ,~nown to have fire resistive qualities. -Irrigation shall be required and maintained. Drip may be utilized. -Trees may be allowed at the discretion of the Fire Cade Official provided that, ai maturity, a 20-foot spacing can be maintained between the tree canopies. Plantings under tree drip line shall be maintained to a height of 24 inches. -All attachments and ancillary structures shall be iqnition res:stant construction and confonn to 1he most current version of the California Residential Cade, Section R-32T, as adapted by the City of Carlsbad. They shall meet or exceed those requirements for construction in a Very High Fire Severity Zone. ZONEA-2 \ -Zone A-2 shall be measured horizontally 20 feet outward from the outlying edge of Zone A-1. < -Planting within this zone shall consist of low water use plant species known to have slow burning, low fuel characteristics. \, • Irrigation shall be required and maintained. Dnp may be uUlized. -Trees may be allowed at the discretion of the Fire Code Official provided that, at maturity a 20-foot spacing can be maintained between the tree canopies. Plantings under tree drip line sha!I be maintaini!'d to a height of 24 inches. ZONE B-3 -Zane 8-3 shall be measured horizontally 20 feet outward from the outlying edge of Zone A-2 . The outer edge of Zone 8-3 shall extend honzontally to a point at least 60 feet from structures or greater. • "High fuel" species, as listed in Appendix C shall not be allowed. -Re-planted non-irrigated shrub hased areas shall be planted in such a way to create a mosaic, or at 50% coverage. Groupings of plants is acceptable, maintained to less than three (3) feet in height at maturity. Dead and excessively twiggy growth shall also be removed. Annual grasses shall be weed whipped. -May be irrigated, non-irrigated, or temporarily irrigated. May ccn1ain hard surfaces, considered non-combus~ble. ( Modified Condition C -Lot 52 Fair Oaks/Southern Preserve APN 2230615400 Address: 7530 CAMINO MINERO Fuel modification zones for manufactured or natural slopes which occur outside the buildable pad area. The following conditions may apply: ZONE C-1 -Measured horiL011tally 20 feet outward rrom a beginning location on lhe buildab!e pad area -Plaf]t~d with ground cover or law growing shrubs species (less than three (3) feet in height) known ta have fire resistive qualftJes. -Trees and shrubs are allowed. • Irrigation shall be required and maintained. ZONE C-2 -Measured horizontally 20 feet outward from the outlying edge of Zane C-1. This condiUan may exist in either a manufactured slope or a native slope. -Zone standards arc as follows: -For manufactured slopes refer to Condition A -Zone A-2. -For natural slopes with native or hazardous vegetation refer to Condition B -Zone B-3 , -May contain hard surfaces, considered non-combus~ble. -If the configuration is Condition A ran irrigated manufactured slope) then trees are allowed provided that, at maturity, a 20 foot spacing can be provided between the tree canopies. ZONE B-3 -Zone B-3 shall be measured horizontally 20 feet outward from the outlying edge of Zor1e C-2 . The outer edge of Zone B-3 shall extend horizontally ta a point at least 60 feet from structures. • "High fuel" species, as listed in Appendix C shall not be allowed. • Re-planted non-irrigated shrub basad areas shall be pianted in such a way to create a mosaic, or at 50% coverage. Groupings of plants is acceptable, maintained to less than three (3) feet in height at maturity. Dead and excessively twiggy growth shall also be removed. Annual grasses shall be weed whipped. -May be irrigated, r,on-irrigated, or temporarily irrigated. May contain l:ard surfaces, considered non-ccmbustible. DRIVEWAY• No trees shall be planted within 10 feet of the driveway, no tree canopy shall cover the driveway. These Fuel Treatment candiuons are unique lo 7530 CAMINO MINERO Lot 52 Fair Oaks/Southern Preserve. It is understood these conditions will be recorded against the Lot. ~ L() I n FER CENTIMETER AT 2!'>0 CENTIGRADE. PROJECT SITE WEEKLY. IMPROPER MAINTENANCE OR FOOR CONDITION SHOULD BE FREFARED BY Tl-II= LANDSCAPE ARCHITECT FROM OF THI= PLANT MATERIAL DURING THE SCHEDULED MAINTENANCE DIMENSIONS FROVIDED SY THE CONTRACTOR rlNAL A&-ElUILT PLANS I (4! CONTRACTOR SHALL PROVIDE PROOF OR CERTIFICATION Ti-lAT CORRECT PERIOD MAY CAUSE POSTPONEMENT OF THE FINAL INSPECTION AND SHALL EIE DRAFTED CLEARL y TO THE SATISFACTION OF Ti-IE CITY, \.ANos2j; "Ac E:3 LJ I LT'' auANTITY OF MATERIAL WAS INSTALLED. EXTEND Ti-IE COMPLETION DATE OF Ti-IE CONTRACT, MAINTE:NANCE AND THE ORIGINAL. MYLARS SHALL ElE SW3MITTED To THE CITY FOR RALPH STONE-s<J ,... srnN~, <-,.:i OJ FE""TILIZER Si-lALL BE CONTINUED UNTIL ALL WORK 15 IN AN ACCEPTAElLE THEIR KEeFING. <v'f,g-1-'•~:'11'\ 1-.,., "~ i.9() (I) MATERl.<~LS SHALL 13E DELlvERED TO THE SITE IN SEALED 13AG!S TAGGED WITi-1 CONDITION. REMOVE STAKES FROM TREES THAT NO LONGER REQUIRE & ASSOCIATES ci: f-- THE MANUFACTURER'$ AN,4L Y5I5, THE TOTAL QUANTITY NEEDED FOR THE STAKING FOR 5UPFORT BEFORE THE END OF THE MAINTENANCE PERIOD, -< W l-+-=fifk'::,2(/i~..,.-;;-/8 ENTIRE PROJECT SHA!..L 61= 5U6JECT TO THE AFFROVA,L AND/OR INSPECTION E3Y FINAL ACCEPTANCE LANDSCAPE ARCFIITECTURE, PLANNING ..., RCE___ EXP.____ DATE en Ti-IE LANDSCAPE ARCHITECT 13EFORe: APPLICATION, CONTRACTOR $HALL AT Ti-IE COMPLETION OF Ti-IE MAINTENANCE PERIOD, ALL AREA$ APPROVED FOR FL.ANTIN& AND 1345 Encinitas Blvd. #630 ,,:---.ti1r.=-r-"----t' PROVIDE PROOF OR CERTIFICATION Ti-lAT THE CORRECT QUANTITY OF MATl=RIAL INCLUDED IN THE CONTRACT SHALL 13E CLEAN ANP FREE OF L"&i~iIJ~t;;,\?}u.~'if'J-JD/4\!t!'Rl"clSE REVIEWED BY: z WAS INSTALLED, DEBRIS AND WEEDS. CLEAN ALL LANDSCAPE DRAINS. PRIOR ENCINITAS, CALIFORNIA 92024 0 (2) COMMERCIAL FE:RTILIZER Si-lALL CONTAIN THE: i"OLLOWING MII\IIHUM PERCE:NTAGE i"INAL ACCie:PTANCE, ALL P1-ANT MATl:::RIAL &HALL 6E ALIVE, (858) 755-3188 _ 1 Q OF 1',JUTRll=NTS 6Y WEIGi-iT, HEALTHY, VIGOROUS AND FREE OF ANY PEST INFE5TATION5, INSPECTOR DATE f--POST ACCEPTANCE MAINTENANCE ~--~-~----------------~-~--~--~-~---~-------------------1 U NITROGEN 10 Cf<ECK TRE:E &TAKING AND TIES l"IONTHL Y TO IN5URE Ti-lAT NO :=J FHOSFHOROU5 ~ DAMAGE i-lAS OCCURRED, SUCH AS RUBBING, Ci-lAFflNGo, 0:::: POTASi-1 8 CONSTRICTION, OR GolRDLINGi, Ti-llN TREES AND REMOVE DEAD, LANDSCAPE ARCHITECT OF WORK f-- (3'! $UFFLEMENTAL IRON FERTILIZi=R Si-lALL ElE ACID IRON PLUS APPLIED AT RATE$ DI5EA5EP AND CROSSIN<:;, 6RANCHES A& NECE55ARY TO INDICATED, MAINTAIN VIGOR AND KEEP PLANTS IN SALANCE WITH Ti-lEIR FIRM: RALPH STONE & ASSOCIATES en (4! PLANTING TA!;;ILETS 51-lALL flE AGRIFORM 2e>-IC>-!'>, 21 AND!;, GRAl"I TA6LETS OR ROOT oY5TEM5 AND AS SITE CONDITIONS WARRANT. DO NOT ADDRESS: ~1~J4~5~EN~C=IN=l~TA~S~B~LV:~D~, ~#~6=30~----Z EQUAL FOR Rl=f'ERENCE TO THE NUM6ER OF TAEJLETS FER PLANT, SEE SECTION TOF TREES OR &TUEi BACK ElRANCHl=S. ALWAYS CUT BACK TO 0 6ELOW ENTITLED "SOIL FRl"'PARATION POR S!-lRUBS AND TREE&'. A LATERAL BRANCH PERIODICALLY INSF!:CT ALL DRAINAGE CITY, ST.: ENCINITAS CA 92D24 --+-------+------------------U [S2E~/ I CITY OF CARLSBAD SIIEETS 32 PLANNING DEPARTMENT PLANTING DETAILS, AND SPECIFICATIONS CT 02-17 SI-IELLEY PROPERTY "FAIR OAKS VALLEY" STRUCTURE& AND CLEAN AS SITE CONDITIONS REQUIRE. KEEF TELEPHONE: (858) 755-3188 SOIL PREPARATION FOR TURF AND C.ROLIND COVERS AREAS DRAINAGE SWALES OPEN AND FREE OF DEBRIS. REMOVE TREE ~-~-----------0 (I! F'RIOR TO AH!"NDINGo, ALL AREAS Si-lALL ElE RIPPED AND CROSS-RIPPED TO A 15A5IN5 IN WINTeR TO PREVENT FONDING AROUND E5TA15LISHED L., .. / T="'ES BY: __________ DATE: _____ · MINIMUM OF 12 INCHES ON CENTER AT A MINIMUM Dl=FTH OF 12 INCHl=S, ""' · RALPH STONE UJ B 13/15 JB FIRE SUPPR. ZON.F: NOTE:S ADDED-LOT 52 "(.z.t;,,; ~ (2) ALL Di:c6Rl5, TRASH AND ROCK 3/4 INCH IN DIAMETER OR LARGER &i-lALL 13E R,L,A, N0.:~1~4~59~------------DATE INITIAL DATE INITIAL DATE INITIAL DWN BY: PROJECT NO, DRAWING NO. > REMOVED AND DISFOSEP OF OFF SITE, REVISION DESCRIPTION CHKD DY: --CT 02-17 440-51 W L..., ____________________________________________________________________________________ R_E_G1_s_TR_A_c_1o_N_E_X_P1_R_A_TI_O_N_o_A_TE_:=-~0~6".:./".'..15"=-=-=-=-=-=-=-=-=-=----L.E_N_G1_N_EE_R_o_F_w_oR_K..L,_ _________________ ...J..o_TH_ER_A_PP_R_o_vA_L__,___c1_TY_AP_P_R_o_vA_L_L_R_v_w_D_B_Y_:_-_-_-_··_-_______________ ___, [)'.'. APPROVED I~ ~!--=~-( -=,, q . :?>-\, . \ "> PLANNING . DATE \ I \ A PILA&TI=I'< PEI'! DETAIL D TW!& OHEET TO f3E LOCATED 2•• OC. /l&'x4&'k1&" iEHFi::RE ~••PANEL& 1-!0EAH POST& A APPROX. 16' oc. 60TTCl1 Cl¼NNleL &LUMPED f3LOCK CAP '4 F<EBAI'! • 24' OC. VERTICAL I ) I ' I ! i16" o..c. i I I i , I ! I I I I I I I I / I I I / I I / I ) I •4 eAA CONT. HORIZONTAL (Tn".! i::lll:::==========::;==:::JLlt::j.-4, S&.. F<C. eueGl'!ADE NOTE, Sl!CTION 1. Al..L CEU.& TO i35 FIU..f::D SOLID UJITl-l G;ROUT. 2. IN&tALL &TEEL AT COl<NF.R& ANt> END& Cf' llJALL5. 50UND WALL PREll&UR!e T!O!=ATleD 4x4 FO&T !WZ)'-·· ··-··-··-·· !&"-··-·-··-•·-· ..... FOUR 5TRAND 5MOOTI-I-WIRS FENCE (WILDLIFE FRIENDL 'r' FENCE) LEc.END: --0---0-WILDLIFE FRIENPL '1" FENCE-SEE DETAIL E Ti-llS &1-lEET -~~-&oUNP WALL • &EE PET AILS A, 6 Ti-llS &1-lEET VIEIII FENCE • &EE DETAIL D, Ti-ll& &1-lEET ----PRIVACY FENCE • &EE DETAIL C, Ti-4I5 51-lEET (NO WOOD FENCING WITHIN IC'2l FT. OF FRONT EDc.E OF FIRE SUFFRES510N ZONE.> T!-lERE &HALL 6E NO COM6U&Ti6LE FENCING, WITl-llN ONE 1-lUNDRED FEET FROM UNDISTURBED NATUFW. VEGoETATION ILA&TEFt PEI'! DlaTAIL 6 THIS SHEET TO ale LOCATED Ill'' OC. 6LIA-1f'ED eLor.-K CAP W!Tl-1 STUCCO /:'!N.!SH "4 f-SeAl-i. • 24" O.C. VERTICAL. '4 eA!< CQNT. flORIZONTAL tTYP.I CONtlNUOU9 CONCRETE FOOTING 1-T· :::'•':-!· ¢·~-"' RE~AR 12• '.:.0 .;•2:i CONTNUOIJ$ ,.__t:~Uft'--~" R.C. &U6""'-=RADE N.T.5. METAL T•f'OtlT 12' IS' 211'' PF<ECA&T CONC"ISTE PILA&TEFt CAP·TAN COLOFt CCNCF<ET!a l!lLOCK 16'5~ /l+--.1\--IS. DOFtADO STONE VleNS!il't NOLANA • HILL&TONE .;..4--C<:>NC!O!=TE FOOTm ~~JIVE ca1FACT!aD N.T.5. 13 PILA5TER ~~11~--~t ;}~d'° 2><2 DOU<;,, FIi'! TRJH (;!Na, IX6 CEDAAFS, •4~1~ i:;aNCl'tETE TO ale 2' A "'5UF<E OOVEf!>. - ,. - -~--!NI$!,! ""'-"DE --::=,,, F<ETE l'OOTING ....... fl ta' DEEP X 1.2' DlA. ·• C PRIVACY FENCE -WOOD I I I r , f i I / / / I ' _/ I I ,' I I I , ' I ! I I / / / / ) I I / / / , , , , , / ,' ; / 1 I I I I I t ' I I I I I / / I I , ' I I I \ I I I I OOA MAINTAINED ORNAMENTAL IRON ACCESS C.ATE I , / : , ' I I ' . _,/ /I' / ,/ , / / . .. , I / I I I , , / / /I J I , , , , , ' , I WILDLIFE FRIENPL '1" FENCE '-,,_14',0A MAINTAINED ORNAMENTAL IRON ACCESS GoATE I II , I I I . , I/ . I I I i (!T. ··1 ~ L .. _., I I .._j r-· r"! ,... /\ f c~ ( ...... , /, r, ;··--\.)rt I \1 ~)r.,, /-~ l .. • I F~'7ING AROUND LOT S-2 FER 1-lOMEOWNER TRAIL 1ACCE&& GATE I I I I /I i I I I I I \ I I \ I \ \ \ \ \ I \ \ I I \ II NOTE, !=OR FENCE DIMEN5IONING FLAN5, 5E:E 5HEET5 L12 AND Ll3. I I I I I I I; / // t POSTS AI B' QC t ,,,.~ '· . ... ~.' . ~ ....... 7'U' . •. ' • - ? ~ - I ; I I / I // ""1AVT' Pun' 51:LF· CLOSING 1411>1!.E& l ! ·, N.T.5. ....., '--' -1•,,1• / 11Jl!l!Na, V ... -/ -.,,,, / 11~• eQ. / .. Tte!NG v .. ····-4' o.c. / = (i'IN!Si-1 • ·'• ,I~ • .. ·'· ,l-!J1f.#r ·1 .. . , ''. . " t .. . -~ f' 1,.,. :•. ;l • ., ; :· ' ~ .~ ~ ., ~ 1'xl' ·e,N:::. TOP • 60TTCl1 ~1s,• eGt rua1NG VSRT<CAL AT 4' o.c.. FO&T !'xi' E>Tl'IUCTUFtA!;; & TEEi. rue ING AT a• -IZ) OJ;. NOTE, ALL STEEL To !OE <>ALY. TU6ULAFi! AND PAJNTED W!Ti-1 ONE COAT Pl'!IMEl't AND O'IE COAT Pl'!IMER AND ONE COAT e-J:111 GI.OS& 6LACK PAlNT. Cet<Tl'IACTOR eHALL 5UlclMIT &HOP DRAW!N:.ll TO D THE O\.LNER.'6 ~F'Rl:e.eN'tATJW:: FFic.lOp;t TO IN.8TALLATJON. VIEW FENCE • ORNAMENTAL IRON N.T.5. , Af'f'l'<OVeD FOR PLANTiN<; AND 'lR'<IGATION Olj!, 'I', j)iWJDJNG !"REGIS!! LOCATION O!" r-1..ANr!N.s Al«E'A I I \ I I \ I j 0 50' GRAPHIC NORTH 100' SCALE 200' 1"=100' "AS BUILT" RCE __ _ EXP ____ _ REVIEWED BY: INSPECTOR DATE DATE LANP6CAFE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOCIATES l-----l---l------------+--+--+----t-----1 ~8 CITY OF CARLSBAD I SH3E2ETS I ~ PLANNING DEPARTMENT :==='...'::::==========='....'.=:=:; Si"IOOTI-IWIRE N.T.5. RALPH STONE & ASSOCIATES LANDSCAPE ARCJITTECTURE • PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS, CA 92024 TELEPHONE: {858) 755-3188 BY: -~~-cc=c=----DATE: RALPH STONE R.L.A. N0.:~1~4=59~------------ R[GtSmA TION EXP/RAT/ON DA TE: ......l,0"'6.;..(.L.15,_ ___ _ 1 DAl'E INlllAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL DAl'E INIT!AL CITY APPROVAL FENCING PLAN CT 02-17 "FAIR APPROVED 11-Zl PLANNING DWN BY: CHKD BY: RVWD BY: SHELLEY PROPERTY OAKS VALLEY" l.<-E:,ILot IP-~-1'7 DATE PROJECT NO. I DRAWING NO, CT 02-17 440-5L i i •: ' I THERE SI-IALL BE NO COM6LIST16LE FENCING WITI-IIN ONE HUNDRED FEET FROM LINPISTLIRBED NATURAL VEGETATION. SEE SHEET Lil FOR FENCING AND WALL DETAIL$ NOTE, FENC-IN.S/V'IALLS TO BE CENTER.ED ON PROPER.TY LINES UNLESS OTHER.V'115E NOTED. DIMENSIONS INDICATED ARE FR.OM PROPER.TY LINE LOCATIONS UNLESS OTHER.V'IISE NOTED. FINAL LOCATION OF FENCE TO BE DETERMINED AT TIME OF HOU$E CON$TRUCTION RALPH STONE & ASSOCIATES LA.NDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LANDSCAPE ARCHITECT OF WO!-al< FIRM: RAI PH STONE: &: ASSOCIATES ADDRE:SS: 1345 ENC/NIT AS BL VD. #630 CITY, ST.:_ ENCINITAS. CA 92024 7ELEPHONE:: (858) 755-3188 BY: _________ DATE: ___ _ RALPH STONE R.L.A. NO.:~1~45=9~---------- REGISTRA T1ON EXPIRATION DA 1E: ~D"-'6,'-'11=5 ___ _ I RCE __ _ REVIEWED BY: n I _J 1-w w I (I) w w (I) w z _J I (_) I- <( 2 "AS BUILT" EXP. ___ _ DATE DATE L-1 2 INSPECTOR -------'--:=.::::;;:;;:::;==::::;;:==:::::::::::;;;;:::;:::::::::;;==;;;:::::;~;:;:;::;;;:;i ~ CITY OF CARLSBAD ~ f---+--+---------------+-------11---t---,l----j :=~==9==-'===P:::lA::::N:::N::::IN:::::G=D::::E::::P=AR=T=M=E=NT==='._'L_Rj==2==: DAlE INITIAL DAlE INlllAl DATE INITIAL ENW!EER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL FENCING DIMENSION PLAN CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" PLANNING DATE DWN BY: __ _ PROJECT NO. DRAWING NO. CHKD BY: __ _ RVWD BY: CT 02-17 440-51 w z __J I u f- <( 2 I ,I I RALPH STONE & ASSOCIATES LANDSCAPE ARCHITECTURE• PLANNING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA. 92024 (858) 755-3188 I I I I I . I LANDSCAPE ARCHITECT OF WORK ~ FIRM: RALPH STONE & ASSOCIATES ···--- ADDRESS: 1345 £NC/NITA$ BL VD. 11630 CITY, ST.: £NC/N/TAS, CA 92024 TELEPHONE: (858) 755-3188 BY: ~~~-----DATE: ___ _ RALPH STONE RLA. N0.:~14=5=9 _________ _ REGISTRATION EXP/RATION DA TE: -,06"'"/~1.5,_ __ _ I LEGEND: --ci----:o-WILDLIFE FRIENDLY FENCE _ __,_,_,__,__ SOUND WALL --------VIEW FENCE PRIVACY FENCE (NO WOOD FENCING WITHIN IIZ)e> FT. OF FRONT EDGE OF FIRE 6UFFRESSION ZONE.) THERE SHALL BE NO COMBUSTIBLE FENCING WITHIN ONE HUNDRED FEET FROM UNDISTURBED NATURAL VEGETATION. $EE SHEET Lil FOR FENCING AND WALL PET AIL$ NOTE: FENCING/WALLS TO BE CENTERED ON PROPERTY LINES UNLESS OTHERWISE NOTED. 0 40' 80' 160' GRAPHIC SCALE 1''=40' APPROVED l'O!t PI..AHTIN6 AND IRRIGATION ONJ.. 'f, INCWDINe FREC,191= LOCATION OF PL"'NT1Ne AREA DIMENSIONS INDICATED ARE FROM PROPERTY LINE LOCATIONS UNLESS OTHERWISE NOTED. "AS BUILT" RCE __ _ REVIEWED BY: L-13 INSPECTOR I DATE DATE I S3HEOET] CITY OF CARLSBAD I S3HE2ETS I l----t-----1--------------+----t---t------t----l PLANNING DEPARTMENT l----+-~------------------1---i----;----1 l----t-----1--------------+----t---t------t----l /FENCING DIMENSION PLAN [ 1----+--1------------+--+----i---r-----i ,err 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED 1----t-----l-,s:--------------t----J--t---t---j ~P:::LA;:;N:::;N~IN::::G==:::;--;::::==:;:;::;:::::::;::;;:::===D::::A:::TE::';:· ==:::::::;=::===: l--,~,-l-=~-'---------------+-=-==--l-=-:::-:-,-+--:~-t-=.,.,---1 DWN BY: ---PROJECT NO. I DRAWING NO. DATE INITIAL DATE INlllAL DAT£ INITIAL ENGINEER OF WORK REVISION DESCRIPTION 1--0-TH_E_R -AP,_PR_O_VA_L __ CIT_Y_A~PP_R_OV-A--IL ~~~g ~~~ --~_C_T_0_2_-_1_7_~ 440-5L I I I I I I I I \ I I \ I L_ 20' TRAIL EASEMENT MINIMt;M 6' VARlE5 SPECIFIC. 1'l<AIL LOC.AT!ONS AND WIDTH!'> SHALL UTILIZE EXISTING EXISTIN"1 PATHS AND NATi!RAI. SU~ACES WHEF<1:: P05516LE AS Tl-£ HIGHEST PRIORITY. TRAIL IMPROVEMENTS SHALL BE MINIMAL AND NOT INCl<EASE C.AIJSE FOR UNDUE DISrJR.eANCE AND/OR EROSION TO NATIVE AREAS. NOTE, NATIVE 1'l<All.S TO BE MAINTAINED 6'f THI; C.IT'l". A NATIVE AREA TRAIL NT5. !I' D.e TRAIL 5' DEeP DEC.OKPOSED eRANITE PATH -TAN COLOR NOTES, I. SLOPE TRAIL IN DIRECTION OI' PARl<WA'f OR PROVIDE MINIMUM 2lll CR055 SLOP!; IN Dl!<EC,TJON OF WATERSHED. :2. C.IT'l" STANOAR!:I FOR HEADfR IS :2x6 PRESl'i!JRE 1REATED HOOD, 6UT Tl-£ C.IT'f HIW. ACc.fPT 2x6 Tf<EX. NOTe, PAl".l<:J,,IA'f TRAILS TO 6E MAINTAINED 6'f THE HOMEOHNER.'5 ASSOC.IATiON. B PARKHAY TRAIL NT5. (D TAAIL EASEMENT AS SHOJ"IN ON Pl.AN @ El<SHT FOOT WIDE DEc.oMPOSW GRANITE TRAIi., @ /t ~ MURCH MAIN'fl=N1!'.IP!= zo~ f'.t'lfi,.ji TJfsES. ZONE. L~~T~~~,f'aii. ~5 K,lYTB!'f ALLOHED. @ ~~KPOSAEDN ~~iTE~J;:IIT,:!,~TABIJ..1,~ COLO,_R~)-ALBE =~ORT . ~=rdT ~·..-= TO o,~-R FOR~•~• . IN5TALJ.. IN 1WO LIFTS. COKPAC.T BETWEEN J..IFTS IN ACCOROANC.E 1-slTH SPECIFICATIONS. NCTES, @ 2X6 PRESeURE TREATED J..UK6ER FLUSH WITH TRAIL <SAADE. @ 2Xl:2 PRE55URe TREATED DOUGLAS FIR. STAKE WtrH I" CHAMFER CUT. INSTALL b' O.C. AND >"<HERE 1WO BOARDS MEST. (J) 2' DEEP X lb" WIDE MULCH AREA OR OPl;N SPAC.E, l'LLY'c>H WITH HEADER SOARt>, 1/4' TOLEAANCE @ ~Ol\\ COKPACi'ED NATIVE SOIL. @) FIN15HED GAADE. NOTES, A. TRAIL WIDTH MA'f VAR'f DS"ENDING UPON LOCATION WITHIN OPEN SPACE OR LANDSCAPED AREAS. TRAIL WIDTH TO SE b' UNLE55 SPl'5CIFIED OT,-£RW15E. 6. C,ONTRAc:roR eHAU. PROVIDE: POSITIVE DRAINAel!: FOR THE TRAIL, KJN. 2% CR055 SLOPE: IN DIREC.TION OI' J"iATER SHED OR C,ROWNED FROM CS.TERJ..INE OF TRAIL. C, SPLICES AT .JOINTS TO SE lx4 REDWOOD, D. NAIJ..S TO 6E GALV. COMMON NAll-5, NAIL AB REGlilRED FOR SOLID INSTALLATION. E. ON WRNS ANO Clll'tYE5, BENDER BOARDS TO 1-".ATCH EDGING WIDTH (4" DEFn\) IN PL.ACE OF 2X4 SHALL 6E USED. F. A 2" WIDE MULCHED KAINTENANGe AREA ON 60TH SIDES OF TRAIL. SHALL 6E PROVIDED (OHIT IN NATIVE OPl;N SPAc.E AREAS). e. HATERIALS AND METHODS FOR TRAIL CONSTRliCTION SHALi-Ele IN Ac.WR.DANCE WITH ATTAC,HED SPECIFICATIONS. SEE 5PECIFIC,ATION5 THIS SHEET. 6. Placemen! of Decomposed G,anile Screenings or crushed 3.16" or¼~ minus aggregate screenings: Place aggrega~ i"i lifts and deplhs shown on standard drav.1nge. lnslall per Stabrnzer Solutions ree9_rnmendat1ons, comP,act ?99regite scr,:enl.ngs to 65% re!atve compaction with a double d•um roner 12-4 !oh) or sing~ drum roll•r 11000 lbs.) or o'brato!Y plate tamp. Do not ;egI, com)l{lctloo for6 hours after placemellt and moisture penetration. However, compacf.cn must be completed wiftiln 48-hoorn of plecemenl and rnolsture penelraUcn C, ReP.cl!rs and Prote-ction--Remove and tep!ace stabilized decompqsed granite crushed 3/B~ or ¼" minus aggregate paving th.al is damaged, tlafoc:Uva or does not meet requirements of this $ection. Repairs can be made by the folfowing sleps: 1,Roto till damaged area to the dep!h of the slabl!ized aggregate and square up skie walls 2. If area is dry, moisten damaged po~rni lightly. 3, Pre-blend the df)I required amount of stabilizer powder with the proper amount of aggregate in a concrete ml)(f;lf. (12 lbt par lon) 4. Add .water lo the pre-blended agg_reg~te arid slablllzer. l11oroughly moisten mix to 25 to 35 gallons per tan of pre-blended material !o approximately 10% moisture contenL 5. Apply moistened pre-blended aggregate to rutted or e-xcavated area to finish grade. -5, Compact with a vibrafing plate compactor or 1000 lb, drum roller. Keep traffic off area5 for 12 to 48 hours after repair has been complotod, D. Maintenance/R~airs-During the first yea: a minor amount of loose aggregate will appear on the surface ( 1/16" lo¼") lf this material exceeds a ¼ft depth, redistribute the material over the anti.ra: surface. Remove debris, suet, as grass clippingsihleaves or other materials by mechanlcallv blowing or hand' raking the suriace as needed', Fill in areas with supp!emental stabilized dg. Water oroug111yto the depth of 1", Compact wlth power roller or no less lhan 1000 lbs. For ruts greater than ¼• In depth, scarify or rototill area and supplement with additions.I s!abllized decom~osed grariite rnalerlals to bring surface to original grade. Waler thoroughly to a depth of 1~. compact with power roller of no less than 1000 tbs. If era eking occurs, simply swee fines lnto the cracks, watar lhoroughly and hand tamp with an 8"-10• hand tamp plate, "AS BUILT'' ALI-DEc.oMf'OSED c<;RANITE MATERIALS SHALL CONTAIN A 5TA61LIZIN5 ADDITIVE IN AecOROANcE HITH THE SPl!:C,IFICATIONS. TRAILS THAT ARE CON5TRI.JCTED AElWTTINS, WALJ..5, DITCHES, CLIR65 OR OTl<E!R STRliCTURES W!LL NOT REG!LII~ WOOD EDelNe AT eD6E(S) THAT A~ ADJACENT TO SUCH STI'WerJRES. RCE __ _ EXP ___ _ DATE REVIEWED BY: C TYPICAL STABILIZED DECOMPOSED 6RANITE TRAIL WITH WOOD HEADER NT5 RALPH STONE & ASSOCIATES LANDSCAPE ARCIIlTECTURE • PLAN1''ING 1345 Encinitas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 LAND$CAFE ARCHITECT OF I.UORI< FIRM: RA/ PH STONE & ASSOC/A TES ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS CA 92024 TELE PHONE: (858) 755-3188 -14 INSPECTOR DATE f-----+---f------------+--+--+--+---------i ~1 CITY OF CARLSBAD ~2 Ul_j PLANNING DEPARTMENT ~ :==:.-=========~~~ 1----1---+-----------------J-........................ --t-----+---; TRAIL PLAN 1------+---1---------+--1-----t-----t---i 1CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" APPROVED 1i.:J BY: -~~~~----DATE: PLANNING RALPH STONE R.L.A. NO.:_l~4~5~9-------------DATE INITIAL DATE INITIAL DATE INITIAL DWN BY: PROJECT NO. CT 02-17 DRAWING NO. 440-51 REGISTRATION EXPIRATION DATE:~0""61~1..,_5____ ENGINEER OF WORK REVISION DESCRIPTION DTHER APPROVAL CITY APPROVAL 2~~g g:✓, .......... _ L----------·-------------............... ________________________________ _:_::==~==::.:....::.:..:.:.:::.=====:___i::__.:.:__:::::.:._:_:_~__1_ ___________ ....J..=:..:.::..:=:...i------------1..'.::::::::=:====~'...':::::=================:::'.J I I I I I \ I I I / / , _,,// -;;;;;;;:;;;;,i,;;~;iisi~~~ ---'i5-r s;.;: --~ "" . / ,,-,y , I / ½,,Y / ,:-: ]: _,A (1 ,:,. 'T ,j 1/!/ "'•., ..... ·-'" ' '.'.' ' 9 601 FIRE SUPPRESS I ON AREA I L __ _ ' Q . -' \ '.~~ . .? I I I I I I I I I I I I I I I I I I I I I I I I I I I ., r) iL . ·. 1 7 I I I I MAINTENANCE RESPONSIBILITY PLAN SLOPES AND RIGHT OR WAY LANDSCAPE AREAS HOMEOJAINER 1S ASSOCIATION MAINTAINED PRESERVE AREA MAINTAINED :30,215 SQ.FT. SLOPES 61,5'11 SQ.FT. RIGHT OF JAIAY 11,315 SQ.FT. BASIN 226)5'11 SQ.FT. SLOPES 86,:340 SQ.FT. SLOPES RALPH STONE & ASSOCIATES '•:• LANDSCAPE ARClfITECTURE • PLANNING 1345 Encinjtas Blvd. #630 ENCINITAS, CALIFORNIA 92024 (858) 755-3188 ..... ❖:=, .. _~ ::~::: ·•-,.,,.-:~::·:_, ··= ::~·::·· ;-~:-?r? ·-··'•':=...~ _., LANDSCAPE ARCHITECT OF WORK FIRM: RALPH STONE & ASSOC/A TfS ADDRESS: 1345 ENCINITAS BLVD. #630 CITY, ST.: ENCINITAS. CA 92024 TELEPHONE: (858) 755-3188 BY: -=c::7-::-;-c-==----DATE: ___ _ RALPH STONE R.L.A. N0.:__,.1'"'45""9 __________ _ REGIS'/RATION EXPIRATION DATE: _06..,/~15 ___ _ 0 1 FIRE SUPPRESSION AREA I \ I \ I I \ \ \ \ \ I ·T£::1----1-~ HO A HA I NT A I NED BRUSH \ I : I I / / / / , / . , . / / / ,/ I i HANAiSEHENT AREAS (V'llTHIN LOTS 41,48,4Cf,52 AND V'liTHiN OPEN SPACE LOT 12) NORTH 0 50' 100' GRAPHIC SCALE \ I \ \ I \ \ \ I I \ I \ I ~ \ 200' I 1''=100' I ___ j , --l "AS BUILT" U-~~;:,,.;;;,:-----,8 --, RCE___ EXP. ___ _ AF'F'lsO\'cO FO~ l"LANTIN<S ANO IRRIGATION ONl.iT', ,lt!_CLUDINOS> Pl'-EC,ISe Loc;.A TION OF f',.,.,,.;-11-le> AREA , .. 'c:::::;::C::;:A::;:L\f~ REVIEWED BY: -15 INSPECTOR DATE DATE ~-CITY OF CARLSBAD ~2 1----1--+----------------t----t---t---t--~ ~ PLANNING DEPARTMENT ~ 1----+---+--------------t--i---t---i----: l-----l--+----------------t----t---t---1--, MAINTENANCE PLAN r DATE INITIAL DA TE INITlAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL CT 02-17 SHELLEY PROPERTY "FAIR OAKS VALLEY" CITY E~40I14EEi< flt:-EXPIRES DATE DWN BY: __ _ PROJECT NO. DRAWING NO. CHKD BY: __ _ RVWO BY: CT 02-17 440-51