Loading...
HomeMy WebLinkAbout2535 GLASGOW DR; ; AS160115; Permit10/20/21 11:26 AM AS160115 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2535 GLASGOW DR Permit Type: SPRINK Parcel No: 2081911500 Lot #: 0 Reference No.: Permit No: AS160115 Status: ISSUED Applied 5/2/2016 Approved: 6/9/2016 Issued: 6/9/2016 PC #: Inspector: Project Title: 2535 GLASGOW DR SFR: 4,994 SF LIV / 648 SF GAR / 248 SF PATIO THIS SUBMITTAL TO CONSIST OF THE BLUFFS PA 5 LOTS 25-60 36 SFR Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEECA (619) 593-8200 (619)593-9133 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 798 0 798 0 1/1 AS160115 2535 GLASGOW DR 2539 GLASGOW DR, 2543 GLASGOW DR 2547 GLASGOW DR, 2551 GLASGOW DR 2555 GLASGOW DR, 2559 GLASGOW DR 2563 GLASGOW DR, 2567 GLASGOW DR 2571 GLASGOW DR, 2575 GLASGOW DR 2579 GLASGOW DR, 2583 GLASGOW DR 2587 GLASGOW DR, 2591 GLASGOW DR 2595 GLASGOW DR, 2599 GLASGOW DR 2526 GLASGOW DR, 2530 GLASGOW DR 2534 GLASGOW DR, 2538 GLASGOW DR 2542 GLASGOW DR, 2546 GLASGOW DR 2550 GLASGOW DR, 2554 GLASGOW DR 2558 GLASGOW DR, 2562 GLASGOW DR 2566 GLASGOW DR, 2570 GLASGOW DR 2574 GLASGOW DR, 2578 GLASGOW DR 2582 GLASGOW DR, 2586 GLASGOW DR 2590 GLASGOW DR, 2594 GLASGOW DR 2598 GLASGOW DR INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 1 (LOT 51) (1HD) 2571 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 315 sq. ft. COVERAGE PER SPRINKLER: 20x20-400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinkler TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTALS WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR): 21.0 gpm @ 28.7 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. AS 160115 2535 GLASGOW DR E 0 0 0 LU 0 (I) 0 0 LU SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016R5 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV)-LOT 51(1HD).SDF JOB TITLE: THE BLUFFS 0 0 0 0 0 ••• 0 0 0 0• 0 0 0 I 0 C N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016R5 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV)-LOT 51(1HD).SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 9 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.6 26.0 52.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE - 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES , 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 202.0 SOURCE 52.2 26.0 2 202.0 - - - - 42.8 - - - 2A 202.0 - - - - 41.8 - - - D 202.0 - - - - 41.5 - - - C 202.0 - - - - 35.5 - - - 2B 202.0 HOSE STREAM 34.2 5.0 2C 202.0 - - - - , 34.0 - - - 3A 206.0 - - - - 30.8 - - - 3B 208.0 - - - - 29.8 - - - 3 210.0 - - - - 28.7 - - - 4 212.0 - - - - 26.9 - - - 5 216.0 - - - - 23.6 - - - 6 218.0 - - - - 21.2 - - - 7 218.0 - - - - 21.2 - - - 8, 218.0 - - - - 20.1 - - - 101 218.0 - - - - 21.2 - - - 102 218.0 - - - - 21.2 ' - - - 103 218.0 K= 4.90 18.4 21.0 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016R5 SYSTEMS\JP CALCS\THEBLUFFS-PLAN 1(REV)-LOT 51(1HD).SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 45.00 150 9.4 1 202.0 52.2 26.0 2A K1.000 T: 6.0 7.00 0.0 2 202.0 42.8 26.0 0.995 G: 1.0 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 42.8 26.0 D 1.0 psi; 26.0 gpm 2A 202.0 41.8 26.0 Pipe: 3 0.0 0.0 2.00 150 0.3 2A 202.0 41.8 26.0 C L1.000 ---- 0.00 0.0 D 202.0 '•41.5 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device D 202.0 41.5 26.0 28 6.0 psi, 26.0 gpm C 202.0 35.5 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 202.0 35.5 21.0 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 34.2 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0.0 0.0 2.00 150 0.2 2B 202.0 34.2 21.0 3A L1.000 ---- 0.00 0.0 2C 202.0 34.0 21.0 1.025 2.00 0.105 0.2 Pipe: 7 0.0 0.0 36.00 150 3.2 2C 202.0 34.0 21.0 38 1.250 ---- 0.00 -1.7 3A 206.0 30.8 21.0 1.244 36.00 0.041 1.5 Pipe: 8 0.0 0.0 3.00 150 1.0 3A 206.0 30.8 21.0 3 1.250 ---- 0.00 -0.9 38 208.0 29.8 21.0 1.244 3.00 0.041 0.1 Pipe: 9 0.0 0.0 3.00 150 1.1 38 208.0 29.8 21.0 4 F1.000 ---- 0.00 -0.9 3 210.0 28.7 21.0 1.101 3.00 0.074 0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 210.0 28.7 21.0 5 A1.000 C: 5.0 5.00 -0.9 4 212.0 26.9 21.0 1.049 7.00 0.142 1.0 Pipe: 12 0.0 10.4 8 9.00 150 3.3 4 212.0 26.9 10.6 6 F1.000 E: 7.0 12.00 -1.7 5 216.0 23.6 21.0 1.101 B: 5.0 21.00 0.074 1.6 Pipe: 13 0.0 0.0 54.00 150 2.4 5 216.0 23.6 10.6 8 F1.000 2E:14.0 19.00 -0.9 6 218.0 21.2 10.6 1.101 B: 5.0 73.00 0.021 1.5 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016RS SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV)-LOT 51(1HD).SDF JOB TITLE: THE BLUFFS - Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: .13A 0.0 21.0 103 84.00 150 3.5 5 216.0 23.6 -10.6 103 F1.000 5E:35.0 45.00 -0.9 8 218.0 20.1 10.4 1.101 2B:10.0 129.00 0.020 2.6 Pipe: 14 0.0 0.0 11.00 150 0.0 7 218.0 21.2 0.0 F1.000 B: 5.0 5.00 0.0 6 218.0 21.2 0.0 1.101 16.00 0.000 0.0 Pipe: 15 0.0 0.0 12.00 150 0.0 101 218.0 21.2 0.0 F1.000 E: 7.0 7.00 0.0 7 218.0 21.2 0.0 1.101 19.00 0.000 0.0 Pipe: 16 0.0 0.0 1.50 150 0.0 102 218.0 21.2 0.0 F1.000 E: 7.0 7.00 0.0 7 218.0 21.2 0.0 1.101 8.50 0.000 0.0 Pipe: 18 4.90 21.0 Disch 11.00 150 1.7 8 218.0 20.1 0.0 F1.000 E: 7.0 12.00 0.0 103 218.0 18.4 21.0 1.101 B: 5.0 23.00 0.074 1.7 Pipe: 19 0.0 21.0 103 48.00 150 1.1 6 218.0 21.2 -10.4 5 F1.000 B: 5.0 5.00 0.0 8 218.0 20.1 10.6 1.101 53.00 0.021 1.1 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.006 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Note INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 1 (LOT 51) (2HD) 2571 GLASGOW' DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 233 sq. ft. COVERAGE PER SPRINKLER: 18'X18'-324 sq. ft. NUMBER OF SPRINKLERS' CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 34.4 gpm TOTAL WATER REQUIRED (including hose): 39.4 gpm FLOW AND PRESSURE (@ BOR) : 34.4 gpm @ 31.4 psi SPRINKLER ORIFICE SIZE: ' 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV2)LOT 51(2HD).SDF JOB TITLE: THE BLUFFS w-1 0 0 0 0 0 • • • • 0 0 0 0 0 0 0• ci' (N I 0 (N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV2)LOT 51(2HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID, FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.5 39.4 73.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 39.4 GPM TOTALHOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 202.0 SOURCE 73.6 39.4 2 202.0 - - - - - 53.3 - - - 2A 202.0 - - - - 50.3 - - - D 202.0 - - - - 49.6 - - - C 202.0 - - - - 42.6 - - - 2B 202.0 HOSE STREAM 39.9 5.0 2C 202.0 - - - - 39.4 - - - 3A 206.0 - - - - 34.0 - - - 3B 208.0 - - - - 32.8 - - - 3 210.0 - - - - 31.4 - - - 4 212.0 - - - - 28.0 - - - 5 216.0 - - - - 22.4 - - - 6 218.0 - - - - 16.0 - - - 7 218.0 - - - - 13.0 - - - 8 218.0 - - - - 17.6 - - - 101 218.0 K= 4.90 12.0 17.0 102 218.0 K= 4.90 12.6 17.4 103 218.0 - - - - 17.6 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV2)-LOT 51(2HD) .SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 45.00 150 20.3 1 202.0 73.6 39.4 2A K1.000 T: 6.0 7.00 0.0 2 202.0 53.3 39.4 0.995 G: 1.0 52.00 0.390 20.3 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 53.3 39.4 D 3.0 psi, 39.4 gpm 2A 202.0 50.3 39.4 Pipe: 3 0.0 0.0 2.00 150 0.7 2A 202.0 50.3 39.4 C L1.000 ---- 0.00 0.0 D 202.0 49.6 39.4 1.025 2.00 0.337 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 202.0 49.6 39.4 2B 7.0 psi, 39.4 gpm C 202.0 42.6 39.4 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 202.0 42.6 34.4 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 39.9 39.4 1.025 8.00 0.337 2.7 Pipe: 6 0.0 .0.0 2.00 150 0.5 2B 202.0 39.9 34.4 3A L1.000 ---- 0.00 0.0 2C 202.0 39.4 34.4 1.025 2.00 0.262 0.5 Pipe: 7 0.0 0.0 . 36.00 150 5.4 2C 202.0 39.4 34.4 3B 1.250 ---- 0.00 -1.7 3A 206.0 34.0 34.4 1.244 36.00 0.102 3.7 Pipe: 8 0.0 0.0 3.00 150 1.2 3A 206.0 34.0 34.4 3 1.250 ---- 0.00 -0.9 3B 208.0 32.8 34.4 1.244 3.00 0.102 0.3 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 208.0 32.8 34.4 4 F1.000 ---- 0.00 -0.9 3 210.0 31.4 34.4 1.101 3.00 0.185 0.6 Pipe:-10 0.0 0.0 2.00 120 3.3 3 210.0 31.4 34.4 5 A1.000 C: 5.0 5.00 -0.9 4 212.0 28.0 34.4 1.049 7.00 0.354 2.5 Pipe: 12 0.0 13.0 8 9.00 150 5.6 4 212.0 28.0 21.3 6 F1.000 E: 7.0 12.00 -1.7 5 216.0 22.4 34.4 1.101 B: 5.0 21.00 0.185 3.9 Pipe: 13 0.0 34.4 7 54.00 150 6.5 5 216.0 22.4 -13.0 8 F1.000 2E:14.0 19.00 -0.9 6 218.0 16.0 21.3 1.101 3: 5.0 73.00 0.077 5.6 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 1(REV2)-LOT 51(2HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 13A 0.0 0.0 84.00 150 4.8 5 216.0 22.4 13.0 6 F1.000 5E:35.0 45.00 -0.9 8 218.0 17.6 13.0 1.101 23:10.0 129.00 0.031 4.0 Pipe: 14 0.0 17.4 102 11.00 150 3.0 6 218.0 16.0 17.0 101 F1.000 B: 5.0 5.00 0.0 7. 218.0 13.0 34.4 1.101 16.00 0.185 3.0 Pipe: 15 4.90 17.0 Disch 12.00 150 1.0 7 218.0 13.0 0.0 F1.000 E: 7.0 7.00 0.0 101 218.0 12.0 17.0 1.101 19.00 0.050 1.0 Pipe: 16 4.90 17.4 Disch 1.50 150 0.4 7 218.0 13.0 0.0 F1.000 E: 7.0 7.00 0.0 102 218.0 12.6 17.4 1.101 8.50 0.052 0.4 Pipe: 18 0.0 0.0 11.00 150 0.0 103 218.0 17.6 0.0 F1.000 K: 7.0 12.00 0.0 8 218.0 17.6 0.0 1.101 B: 50 23.00 0.000 0.0 Pipe: 19 0.0 34.4 7 48.00 150 1.6 8 218.0 17.6 -21.3 5 F1000 B: 5.0 5.00 0.0 6 218.0 16.0 13.0 : 1.101 53.00 0.031 1.6 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The: system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.004 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.2 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Note INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 2 (LOT 52) (1HD) 2567 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 176 sq. ft. COVERAGE PER SPRINKLER: 20X20'-400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinkler TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR) : 21.0 gpm @ 34.3 psi SPRINKLER ORIFICE SIZE: 1/2' inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. Q Q 0 LU 0 (I) 0. 0 LU SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV)-LOT 52(1HD).SDF JOB TITLE: THE BLUFFS 0 0 0 0 0 • 0 0 0 0• 0• 0 • -1 00 110 (N 0 I C) 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV)-LOT 52(1HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.6 26.0 57.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 202.0 SOURCE 57.8 26.0 2 202.0 - - - - 48.4 - - - 2A 202.0 - - - - 47.4 - - - D 202.0 - - - - 47.1 - - - C 202.0 - - - - 41.1 - - 2B 202.0 HOSE STREAM 39.8 5.0 2C 202.0 - - - - 39.6 - - - 3A 206.0 - - - - 36.5 - - - 3B 208.0 - - - - 35.4 - - - 3 210.0 - - - - 34.3 - - - 4 212.0 - - - - 32.5 - - - 5 216.0 - - - - 25.6 - - - 6 216.0 - - - - 24.6 - - - 7 216.0 - - - - 24.2 - - - 8 216.0 - - - - 23.8 - - - 9 226.0 - - - - 19.2 - - - 10 226.0 - - - - 18.9 - - - 11 226.0 - - - - 18.6 - - - 12 226.0 - - - - 18.6 - - - 13 226.0 - - - - 18.9 - - - 14 226.0 - - - - 19.3 - - - 101 226.0 - - - - 18.6 - - - 102 226.0 - - - - 18.6 - - - 103 226.0 K= 4.90 18.4 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS -PLAN 2 (REV)-LOT 52(1HD) .SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 45.00 150 9.4 1 202.0 57.8 26.0 2A K1.000 T: 6.0 7.00 0.0 2 202.0 48.4 26.0 0.995 G: 1.0 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device - 2 202.0 - 48.4. .26.0 D 1.0 psi, 26.0 gpm 2A 202.0 47.4 26.0 Pipe: 3 0.0 . 0.0 2.00 150 0.3 2A 202.0 47.4 26.0 C L1.000 ---- 0.00 0.0 D 202.0 47.1 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Piessure Loss Device D 202.0 47.1 26.0 2B 6.0 psi, 26.0 gpm C 202.0 41.1 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 202.0 41.1 21.0 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 39.8 26.0 . 1.025 8.00 0.157 1.3 Pipe: 6 0.0 0.0 2.00 150 0.2 2B 202.0 39.8 21.0 3A L1.000 ---- 0.00 0.0 2C 202.0 39.6 21.0 1.025 2.00 0.105 0.2 Pipe: 7 0.0 0.0 34.00 150 3.1 2C 202.0 39.6 21.0 3B 1.250 ---- 0.00 -1.7 3A 206.0 36.5 21.0 1.244 34.00 0.041 1.4 Pipe: 8 0.0 0.0 5.00 150 1.1 3A 206.0 36.5 21.0 3 1.250 ---- 0.00 -0.9 3B 208.0 35.4 21.0 1.244 5.00 0.041 0.2 Pipe: 9 0.0 0.0 3.00 150 1.1 3B 208.0 35.4 21.0 4 . F1.000 ---- 0.00 -0.9 3 210.0 34.3 21.0 1.101 3.00 0.074 0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 210.0 34.3 21.0 5 A1.000 C: 5.0 .5.00 . -0.9 4 212.0 32.5 21.0.. 1.049 7.00 0.142 1.0 Pipe: 12 0.0 0.0 44.50 150 6.8 4 212.0 32.5 21.0 6 F1.000 2E:14.0 24.00 -1.7 5 216.0 25.6 21.0 1.101 2B:10.0 68.50 0.074 5.1 Pipe: 13 0.0 14.2 9 8.50 150 1.0 5 216.0 25.6 6.8 7 F1.000 B: 5.0 5.00 0.0 6 216.0 24.6 21.0 1.101 13.50 0.074 1.0 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV)-LOT 52(1HD).SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) F±m Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 14 0.0 0.0 38.00 150 0.4 6 216.0 24.6 6.8 8 F1.000 B: 5.0 5.00 . 0.0 7 216.0 24.2 6.8 1.101 43.00 0.009 0.4 Pipe: 15 0.0 0.0 34.00 150 0.5 7 216.0 24.2 6.8 14 F1.000 2E:14.0 19.00 0.0 8 216.0 23.8 6.8 1.101 B: 5.0 53.00 0.009 0.5 Pipe: 16 0.0 0.0 10.00 150 4.5 8 216.0 23.8 6.8 13 F1.000 E: 7.0 7.00 -4.3 14 226.0 19.3 6.8 1.101 17.00 0.009 0.2 Pipe: 17 0.0 0.0 . 11.00 150 5.4 6 216.0 24.6 14.2 10 F1.000 2E:1.0 19.00 -4.3 9 226.0 19.2 14.2 1.101 B: 5.0 30.00 0.036 1.1 Pipe: 18 0.0 15.4 103 5.00 150 0.4 9 226.0 19.2 -1.2 103 F1.000 B: 5.0 5.00 0.0 10 226.0 18.9 14.2 1.101 10.00 0.036 0.4 Pipe: 19 4.90 21.0 Disch 7.00 150 0.5 10 226.0 18.9 -5.6 11 F1.000 B: 5.0 5.00 0.0 103 226.0 18.4 15.4 1.101 12.00 0.042 0.5 Pipe: 20 4.90 21.0 Disch 24.50 150 0.2 11 226.0 18.6 -15.4 10 F1.000 E: 7.0 12.00 0.0 103 226.0 18.4 5.6 1.101 B: 5.0 36.50 0.006 0.2 Pipe: 21 0.0 0.0 7.00 150 0.0 11 226.0 18.6 0.0 F1.000 B: 5.0 5.00 0.0 12 226.0 18.6 0.0 1.101 12.00 0.000 0.0 Pipe: 22 0.0 0.0 6.00 150 0.0 101 226.0 18.6 0.0 F1.000 E: 7.0 7.00 0.0 12 226.0 18.6 0.0 1.101 13.00 0.000 0.0 Pipe: 23 0.0 0.0 4.00 150 0.0 102 226.0 18.6 0.0 FLOOD E: 7.0 7.00 0.0 12 226.0 18.6 0.0 1.101 11.00 0.000 0.0 Pipe: 24 . 0.0 0.0 .12 41.00 150 0.3 13 226.0 18.9 5.6 103 F1.000 B: 5.0 5.00 0.0 11 226.0 18.6 5.6 1.101 46.00 0.006 0.3 Pipe: 25 0.0 1.2 10 . 23.00 150 0.4 14 226.0 19.3 5.6 11 F1.000 E: 7.0 17.00 0.0 13 226.0 18.9 6.8 1.101 2B:10.0 40.00 0.009 0.4 Pipe: 26 0.0 15.4 103 54.00 150 0.0 13 226.0 18.9 -14.2 9 F1.000 2B:10.0 10.00 0.0 10 226.0 18.9 1.2 1.101 64.00 0.000 0.0 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV)-LOT 52(1HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) (1) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.135 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPV1v NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngE11 ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R K C G 45 El Tee RunT Kpig ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 2 (LOT 52) (2HD) 2567 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: APRIL 21, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSJTY: .05 gpm/sq. ft. AREA OF APPLICATION: 394 sq. ft. COVERAGE PER SPRINKLER: 18'X18-324 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 34.1 gpm TOTAL WATER REQUIRED (including hose): 39.1 gpm FLOW AND PRESSURE (@ BOR) : 34.1 gpm @ 43.4 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV2)LOT 52(2HD).SDF JOB TITLE: THE BLUFFS 0 0 0 c 0 0 0 0 0 0 0 0 I 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV2)-LOT 52(2HD).SDF JOB TITLE: THE BLUFFS NFPA MATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. S PRESS. S DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.5 39.1 85.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 391 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES • (FT) (PSI) (GPM) 1 202.0 SOURCE 85.2 39.1 2 202.0 - - - - 65.2 - - - 2A 202.0 - - - - 62.2 - - - D 202.0 - - - - 61.5 - - - C 202.0 - - - - 54.5 - - - 2B 202.0 HOSE STREAM 51.9 5.0 2C 202.0 - - - - 51.3 - - - 3A 206.0 - - - - 46.2 - - - 3B 208.0 - - - - 44.8 - - - 3 210.0 - - - - 43.4 - - - 4 212.0 - - - - 41.8 - - - 5 216.0 - - - - 27.6 - - - 6 216.0 - - - - 25.2 - - - 7 216.0 - - - - 24.1 - - - 8 216.0 - - - - 22.8 - - - 9 226.0 - - - - 18.3 - - - 10 226.0 - - - 17.4 - - - 11 226.0 - - - - 14.9 - - - 12 226.0 - - - - 12.7 - - - 13 226.0 - - - - 17.1 - - - 14 226.0 - - - - 18.1 - - - 101 226.0 K= 4.90 12.0 17.0 102 226.0 K= 4.90 • 12.1 17.1 103 226.0 - - - - 16.8 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV2)-LOT 52(2HD).SDF JOB TITLE: THE BLUFFS Ila JS)1W Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 S 45.00 150 20.0 1 202.0 85.2 39.1 2A K1.000 T: 6.0 7.00 0.0 2 202.0 65.2 39.1 0.995 G: 1.0 52.00 0.385 20.0 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 65.2 39.1 D 3.0 psi, 39.0 gpm 2A 202.0 62.2 39.0 Pipe: 3 0.0 0.0 2.00 150 0.7 2A 202.0 62.2 39.1 C L1.000 ---- 0.00 0.0 D 202.0 61.5 39.1 1.025 2.00 0.333 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 202.0 61.5 39.1 2B 7.0 psi, 39.0 gpm C 202.0 54.5 39.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 202.0 54.5 34.1 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 51.9 39.1 1.025 8.00 0.333 2.7 Pipe: 6 0.0 0.0 2.00 150 0.5 2B 202.0 51.9 34.1 3A L1.000 ---- 0.00 0.0 2C .202.0 51.3 34.1 1.025 2.00 0.258 0.5 Pipe: 7 0.0 0.0 34.00 150 5.2 2C 202.0 51.3 34.1 3B 1.250 ---- 0.00 -1.7 3A 206.0 46.2 34.1 1.244 34.00 0.101 3.4 Pipe: 8 0.0 0.0 5.00 150 1.4 3A 206.0 46.2 34.1 3 1.250 ---- 0.00 -0.9 3B 208.0 44.8 34.1 1.244 5.00 0.101 0.5 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 208.0 44.8 34.1 4 F1.000 ---- 0.00 -0.9 3 210.0 43.4 34.1 1.101 3.00 0.182 0.5 Pipe: 10 0.0 0.0 2.00 120 1.6 3 210.0 43.4 34.1 5 A1.000 ---- 0.00 -0.9 4 212.0 41.8 34.1 1.049 2.00 0.348 0.7 Pipe: 12 0.0 0.0 44.50 150 14.2 4 212.0 41.8 34.1 6 F1.000 2E:14.0 24.00 -1.7 5 216.0 27.6 34.1 1.101 2B:10.0 68.50 0.182 12.5 Pipe: 13 0.0 22.6 9 8.50 150 2.5 5 216.0 27.6 11.5 7 F1.000 B: 5.0 5.00 0.0 6 216.0 25.2 34.1 1.101 13.50 0.182 2.5 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV2)-LOT 52(2HD).SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 14 0.0 0.0 38.00 150 1.1 6 216.0 25.2 11.5 8 F1.000 B: 5.0 5.00 0.0 7 216.0 24.1 11.5 1.101 43.00 0.024 1.1 Pipe: 15 0.0 0.0 34.00 150 1.3 7 216.0 24.1 11.5 14 F1.000 2E:14.0 19.00 0.0 8 216.0 22.8 11.5 1.101 B: 5.0 5'3.00 0.024 1.3 Pipe: 16 0.0 0.0 10.00 150 4.7 8 216.0 22.8 11.5 13 F1.000 E: 7.0 7.00 -4.3 14 226.0 18.1 11.5 1.101 17.00 0.024 0.4 Pipe: 17 0.0 0.0 11.00 150 6.9 6 216.0 25.2 22.6 10 F1.000 2E:14.0 19.00 -4.3 9 226.0 18.3 22.6 1.101 B: 5.0 30.00 0.085 2.5 Pipe: 18 0.0 5.1 13 5.00 150 0.8 9 226.0 18.3 17.5 103 F1.000 B: 5.0 5.00 0.0 10 226.0 17.4 22.6 1.101 10.00 0.085 0.8 Pipe: 19 0.0 0.0 7.00 150 0.6 10 226.0 17.4 17.5 11 F1.000 B: 5.0 5.00 0.0 103 226.0 16.8 17.5 1.101 12.00 0.053 0.6 Pipe: 20 0.0 34.1 12 24.50 150 1.9 103 226.0 16.8 -16.6 13 F1.000 E: 7.0 12.00 0.0 11 226.0 14.9 17.5 1.101 B: 5.0 36.50 0.053 1.9 Pipe: 21 0.0 17.1 102 7.00 150 2.2 11 226.0 14.9 17.0 101 F1.000 B: 5.0 5.00 0.0 12 226.0 12.7 34.1 1.101 12.00 0.182 2.2 Pipe: 22 4.90 17.0 Disch 6.00 150 0.7 12 226.0 12.7 0.0 F1.000 E: 7.0 7.00 0.0 101 226.0 12.0 17.0 1.101 13.00 0.050 0.7 Pipe: 23 4.90 17.1 Disch 4.00 150 0.6 12 226.0 12.7 0.0 F1.000 5: 7.0 7.00 0.0 102 226.0 12.1 17.1 1.101 11.00 0.051 0.6 Pipe: 24 0.0 34.1 12 41.00 150 2.2 13 226.0 17.1 -17.5 103 F1.000 B: 5.0 5.00 0.0 11 226.0 14.9 16.6 1.101 46.00 0.048 2.2 Pipe: 25 0.0 16.6 11 23.00 150 1.0 14 226.0 18.1 -5.1 10 F1.000 E: 7.0 17.00 0.0 13 226.0 17.1 11.5 1:101 2B:10.0 40.00 0.024 1.0 Pipe: 26 0.0 16.6 11 54.00 150 0.3 10 226.0 17.4 -11.5 14 F1.000 2B:10.0 10.00 0.0 13 226.0 17.1 5.1 1.101 64.00 0.005 0.3 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 2 (REV2)-LOT.52(2HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) (1) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2.) The system has been calculated to provide an average imbalance at each node of 0.007 gpm and a maximum imbalance at any node of 0.162 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.1 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HNC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet ( (in) E .T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 t INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 3 (LOT 32) (1HD) 2570 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL, SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR) SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RESIDENTIAL/LIGHT .05 gpm/sq. ft. 250 sq. ft. 20X20'-400 sq. ft. 1 sprinkler 2,1.0 gpm 26.0 gpm 21.0 gpm @ 32.8 psi 1/21, inch INNOVATIVE FIRE PROTECTION, INC. JOE PLASSMEYER CARLSBAD FIRE DEPARTMENT C-16 711148 CALCULATIONS BY HAS'S COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(1HD) .SDF JOB TITLE: THE BLUFFS EW - - 0 0 0 0 0 0 0 0 0 0 0 CD (N 0 —QCI) -H - --- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(1HD).SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REO'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.6 26.0 56.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 202.0 SOURCE 56.4 26.0 2 202.0 - - - - 46.9 - - - 2A 202.0 - - - - 45.9 - - - D 202.0 - - - - 45.6 - - - C 202.0 - - - - 39.6 - - - 2B 202.0 HOSE STREAM 38.4 5.0 2C 202.0 - - - - 38.2 - - - 3A 206.0 - - - - 34.9 - - - 33 208.0 - - - - 33.9 - - - 3 210.0 - - - - 32.8 - - - 4 212.0 - - - - 30.9 - - - 5 216.0 - - - - 25.6 - - - 5A 216.0 - - - - 25.2 - - - 6 216.0 - - - - 25.2 - - - 7 216.0 - - - - 24.6 - - - 8 226.0 - - - - 20.0 - - - 9 226.0 - - - - 20.0 - - - 9A 226.0 - - - - 20.0 - - - 10 226.0 - - - - 19.3 - - - 11 226.0 - - - - 20.0 - - - 101 226.0 - - - - 20.0 - - - 102 226.0 - - - - 20.0 - - - 103 226.0 K= 4.90 18.4 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(1HD) .SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fàc Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 45.00 150 9.4 1 202.0 56.4 26.0 2A K1.000 T: 6.0 7.00 0.0 2 202.0 46.9 26.0 0.995 G: 1.0' 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 46.9 26.0 D 1.0 psi, 26.0 gpm 2A 202.0 45.9 26.0 Pipe: 3 0.0 0.0 2.00 150 0.3 2A 202.0 45.9 ' 26.0 C L1.000. ---- 0.00 0.0 D 202.0 45.6 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device D 202.0 45.6 26.0 2B 6.0 psi, 26.0 gprn C 202.0 39.6 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 202.0 39.6 21.0 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 38.4 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0:0 0.0 2.00 150 0.2 2B 202.0 38.4 21.0 3A L1.000 ---- 0.00 0.0 2C 202.0 38.2 21.0 1.025 2.00 '0.105 0.2 Pipe: 7 0.0 0.0 36.00 150 3.2 2C 202.0 38.2 21.0 3B 1.250 ---- 0.00 -1.7 3A 206.0 34.9 21.0 1.244 36.00 0.041 1.5 Pipe: 8 0.0 0.0 5.00 150 1.1 3A 206.0 34.9 21.0 3 1.250 ---- 0.00 -0.9 3B 208.0 33.9 21.0 1.244 5.00 0.041 0.2 Pipe: 9 0.0 0.0 3.00 150 1.1 3B 208.0 33.9 21.0 4 F1.000 ---- 0.00 -0.9 3 210.0 32.8 21.0 1.101 3.00 0.074 0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 210.0 32.8 21.0 5 A1.000 C: 5.0 5.00 -0.9 4 212.0 30.9 21.0 1.049 7.00 0.142 1.0 Pipe: 12 0.0 13.7 5A 21.50 150 5.3 4 212.0 30.9 7.3 6 F1.000 3E:21.0 26.00 -1.7 5 216.0 25.6 21.0 1.101 B: 5.0 47.50 0.074 3.5 Pipe: 13 0.0 6.8 7 36.00 150 0.5 5 216.0 25.6 0.5 5A F1.000 2B:10.0 10.00 0.0 6 216.0 25.2 7.3 1.101 46.00 0.011 0.5 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(1HD).SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 14 0.0 14.2 8 9.50 150 0.5 5 216.0 25.6 -0.5 6 F1.000 B: 5.0 5.00 0.0 5A 216.0 25.2 13.7 1.101 14.50 0.034 0.5 Pipe: 15 0.0 14.2 8 67.50 150 0.0 6 216.0 25.2 -13.7 5 F1.000 E: 7.0 17.00 0.0 5A 216.0 25.2 0.5 1.101 2B:10.0 84.50 0.000 0.0 Pipe: 16 0.0 0.0 43.50 150 0.6 6 216.0 25.2 6.8 9 F1.000 E: 7.0 17.00 0.0 7 216.0 24.6 6.8 1.101 2B:10.0 60.50 0.009 0.6 Pipe: 17 0.0 6.9 10 19.00 150 4.6 7 216.0 24.6 -0.1 9A F1.000 E: 7.0 12.00 9. 226.0 20.0 6.8 1.101 B: 5.0 31.00 0.009 0.3 Pipe: 18 0.0 14.1 10 11.00 150 5.2 5A 216.0 25.2 0.1 9A F1.000 E: 7.0 12.00 -4.3 8 226.0 20.0 14.2 1.101 B: 5.0 23.00 0.036 0.8 Pipe: 19 0.0 0.0 92.00 150 0.0 8 226.0 20.0 0.1 9 F1.000 E: 7.0 22.00 0.0 9A 226.0 20.0 0.1 1.101 3B:15.0 114.00 0.000 0.0 Pipe: 20 0.0 6.9 10 0.50 150 0.0 9A 226.0 20.0 -6.8 7 F1.000 B: 5.0 5.00 0.0 9 226.0 20.0 0.1 1.101 5.50 0.000 0.0 Pipe: 21 0.0 0.1 9 5.00 150 0.0 11 226.0 20.0 -0.1 8 F1.000 B: 5.0 5.00 : 0.0 9A 226.0 20.0 0.0 1.101 10.00 0.000 0.0 Pipe: 22 0.0 0:0 4.00 150 0.0 102 226.0 20.0 0.0 F1.000 E: 7.0 7.00 0.0 11 226.0 20.0 0.0 1.101 11.00 0.000 0.0 Pipe: 23 0.0 0.0 4.00 150 0.0 101 226.0 20.0 0.0 F1.000 E: 7.0 7.00 0.0 11 226.0 20.0 0.0 1.101 11.00 0.000 0.0 Pipe: 24 0.0 21.0 103 : 14.50 150 0.7 8 226.0 20.0 -6.9 103 F1.000 B: 5.0 5.00 0.0 10 226.0 19.3 14.1 1.101 19.50 0.036 0.7 Pipe: 25 4.90 21.0 Disch 5.50 150 0:9 10 226.0 19.3 0.0 F1.000 E: 7.0 7.00 0.0 103 226.0 18.4 21.0 1.101 12.50 0.074 0.9 Pipe: 26 0.0 21.0 103 65.50 150 0.7 9 226.0 20.0 -14.1 8 F1.000 E: 7.0 7.00 0.0 10 226.0 19.3 6.9 1.101 72.50 0.010 0.7 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT32(1HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.079 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatViv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 , 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L K B R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E' T F R K C G N Eli Tee 45-Eli TeeRun Kouplg ChkVlv GatViv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 INNOVATIVE FIRE PROTECTION! INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS V FOR THE BLUFFS PLAN 3 (LOT 32) (2HD) 2570 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR) : V SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RESIDENTIAL/LIGHT .05 gpm/sq. ft. 244 sq. ft. 18X18-324 sq. ft. 2 sprinklers V 34.0 gpm 39.0 gpm 34.0 gpm @ 37.3 psi 1/2" inch V INNOVATIVE FIRE PROTECTION, INC. JOE PLASSMEYER CARLSBAD FIRE DEPARTMENT C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 V HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)LOT 32(2HD).SDF JOB TITLE: THE BLUFFS Q Q Q Q 0 • • • • 0 0 0 0 0 0 • (N 0 I 04 U)-r1-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(2HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 9 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.5 39.0 79.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 39.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 202.0 SOURCE 79.2 39.0 2 202.0 - - - - 59.3 - - - 2A 202.0 -. -, - - 56.3 - - -. D 202.0 - - - - 55.6 - - - C 202.0 - - - - 48.6 - - - 2B 202.0 HOSE STREAM 46.0 5.0 2C 202.0 - - - - 45.5 - - - 3A 206.0 - - - - 40.1 - - - 38 208.0 - - - - 38.8 - - - 3 210.0 - -. - - 37.3 - - - 4 212.0 - - - - 34.0 - - - 5 216.0 - - - - 23.7 - - - 5A 216.0 - - - 22.5 - - - 6 216.0 - - - 22.5 - - - 7 216.0 - - - - 20.3 - - - 8 226.0 - - - - 16.6 - - - 9 226.0 - - - - 14.9 - - - 9A 226.0 - - - - 14.4 - - - 10 226.0 - - - - 16.3 - - - 11 226.0 - - - - 12.6 - - - 101 226.0 K= 4.90 12.0 17.0 102 226.0 K= 4.90 12.0 17.0 103 226.0 - - - - 16.3 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)LOT 32(2HD).SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 45.00 150 19.9 1 202.0 79.2 39.0 2A K1.000 T: 6.0 7.00 0.0 2 202.0 59.3 39.0 0.995 G: 1.0 52.00 0.383 19.9 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 59.3 39.0 D 3.0 psi, 39.0 gpm 2A 202.0 56.3 39.0 Pipe: 3 0.0 0.0 2.00 150 0.7 2A 202.0 56.3 39.0 C L1.000 ---- 0.00 0.0 D 202.0 55.6 39.0 1.025 2.00 0.332 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 292.0 55.6 39.0 2B 7.0 psi, 39.0 gpm C 202.0 48.6 39.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 202.0 48.6 34.0 2C L1.000 T: 7.0 7.00 0.0 2B 202.0 46.0 39.0 1.025 8.00 0.332 2.7 Pipe: 6 0.0 0.0 2.00 150 0.5 2B 202.0 46.0 34.0 3A L1.000 -.--- 0.00 0.0 2C 202.0 45.5 34.0 1.025 2.00 0.257 .0.5 Pipe: 7 0.0 0.0 36.00 150 5.3 2C 202.0 45.5 34.0 38 1.250 ---- 0.00 -1.7 3A 206.0 40.1 34.0 1.244 36.00 0.100 3.6 Pipe: 8 0.0 0.0 5.00 150 1.4 3A 206.0 40.1 34.0 3 1.250 ---- 0.00 -0.9 33 208.0 38.8 34.0 1.244 5.00 0.100 0.5 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 208.0 38.8 34.0 4 F1.000 ---- 0.00 -0.9 3 210.0 37.3 34.0 1.101 3.00 0.182 0.5 Pipe: 10 0.0 0.0 2.00 120 3.3 3 210.0 37.3 34.0 5 A1.000 C: 5.0 5.00 -0.9 4 212.0 34.0 34.0 1.049 7.00 0.347 2.4 Pipe: 12 0.0 21.9 5A 21.50 150 10.4 4 212.0 34.0 12.1 6 F1.000 3E:21.0 26.00 -1.7 5 216.0 23.7 34.0 1.101 B: 5.0 47.50 0.182 8.6 Pipe: 13 0.0 14.0 7 36.00 150 1.2 5 216.0 23.7 -1.8 5A F1.000 2B:10.0 10.00 0.0 6 216.0 22.5 12.1 1.101 46.00 0.027 1.2 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/20165 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)-LOT 32(2HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 14 0.0 20.0 8 9.50 150 1.2 5 216.0 23.7 1.8 6 F1.000 B: 5.0 5.00 0.0 5A 216.0 22.5 21.9 1.101 14.50 0.080., 1.2 Pipe: 15 0.0 14.0 7 67.50 150 0.1 5A 216.0 22.5 -12.1 5 F1.000 E: 7.0 17.00 0.0 6 216.0 22.5 1.8 1.101 2B:10.0 84.50 0.001 0.1, Pipe: 16 0.0 0.0 43.50 150 2.1 6 216.0 22.5 14.0 9 F1.000 E: 7.0 17.00 0.0 7 216.0 20.3 14.0 1.101 2B:10.0 60.50 0.035 2.1 Pipe: 17 0.0 23.8 9A 19.00 150 5.4 7 216.0 20.3 -9.9 10 F1.000 E: 7.0 12.00 -4.3 9 226.0 14.9 14.0 1.101 B: 5.0 31.00 0.035 1.1 Pipe: 18 0.0 9.9 10 . 11.00 150 5.9 5A 216.0 22.5 10.2 9A F1.000 E: 7.0 12.00 -4.3 8 226.0 16.6 20.0 1.101 B: 5.0 23.00 0.068 1.6 Pipe: 19 0.0 34.0 11 92.00 150 2.2 8 226.0 16.6 -23.8 9 F1.000 E: 7.0 22.00 0.0 9A 226.0 14.4 10.2 1.101 3B:15.0 114.00 0.019 2.2 Pipe: 20 0.0 34.0 11 . 0.50 150 0.5 9 226.0 14.9 -10.2 8 F1.000 B: 5.0 5.00 0.0 9A 226.0 14.4 23.8 1.101 5.50 0.094 0.5 Pipe: 21 0.0 17.0 101 5.00 150 1.8 9A 226.0 14.4 17.0 102 F1.000 B: 5.0 5.00 0.0 11 226.0 12.6 34.0 1.101 10.00 0.182 1.8 Pipe: 22 4.90 17.0 Disch 4.00 150 0.6 11 226.0 12.6 0.0 F1.000 E: 7.0 7.00 0.0 102 226.0 12.0 17.0 1.101 11.00 0.050 0.6 Pipe: 23 4.90 17.0 Disch 4.00 150 0.6 11 226.0 12.6 0.0 F1.000 E: 7.0 7.00 0.0 101 226.0 12.0 17.0 1.101 11.00 0.050 0.6 Pipe: 24 0.0 0.0 . 14.50 150 0.4 8 226.0 16.6 9.9 9 F1.000 B: 5.0 5.00 0.0 10 226.0 16.3 9.9 1.101 . 19.50 0.018 0.4 Pipe: 25 0.0 0.0 . 5.50 150 0.0 103 226.0 16.3 0.0 F1.000 E: 7.0 7.00 0.0 10 226.0 16.3 0.0 1.101 12.50 0.000 0.0 Pipe: 26 0.0 23.8 9A 65.50 150 1.3 10 226.0 16.3 -14.0 .7 F1.000 E: 7.0 7.00 0.0 9 226.0 14.9 9.9 1.101 72.50 0.018 1.3 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 5/17/2016S SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV)LOT 32(2HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by (-IRS Systems, Inc. 208 Southside Square Petersburg, TN: 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.012 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.1 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B .G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T ,F R K C G N Ell Tee 45-Eli TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 3 (LOT 43) (1Hb) 526 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR) SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RESIDENTIAL/LIGHT .05 gpm/sq. ft. 250 sq. ft. 20'X20'-400 sq. ft. 1 sprinkler 21.0 gpm 26.0 gpm 21.0 gpm @ 32.8 psi 1/2' inch INNOVATIVE FIRE PROTECTION, INC JOE PLASSMEYER CARLSBAD FIRE DEPARTMENT C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(1HD) .SDF JOB TITLE: THE BLUFFS f 0 • 0 0 0 0 IN 0 co 0 10 (N 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)LOT 43(1HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 119.5 105.0 500.0 119.4 26.0 61.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 170.0 SOURCE 61.9 26.0 2 170.0 - - - - 52.5 - - - 2A 170.0 - - - - 51.5 - - - D 170.0 - - - - 51.2 .- - - C 170.0 - - - - 45.2 - - - 2B 170.0 HOSE STREAM 43.9 5.0 2C 170.0 - - - - 43.7 - - - 3A 176.0 - - - - 34.9 - - - 3B 178.0 - - - - 33.9 - - - 3 180.0 - - - - 32.8 - - - 4 182.0 - - - - 30.9 - - - 5 186.0 - - - - 25.6 - - - 5A 186.0 - - - - 25.2 - - - 6 186.0 - - - - 25.2 - - - 7 186.0 - - - - 24.6 - - - 8 196.0 - - - - 20.0 - - - 9 196.0 - - - - 20.0 - - - 9A 196.0 - - - - 20.0 - - - 10 196.0 - - - - 19.3 - - - 11 196.0 - - - - 20.0 - - - 101 196.0 - - - - 20.0 - - - 102 196.0 - - - - 20.0 - - - 103 196.0 K= 4.90 18.4 21.0 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTENS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(1HD) .SDF JOB TITLE: THE BLUFFS - NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frrn Node El (ft) PT (q) Node! Worn ID Eq.Ln. F (Pe) NotE To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 45.00 150 9.4 1 170.0 61.9 26.0 2A K1.000 T: 6.0 7.00 0.0 2 170.0 52.5 26.0 0.995 G: 1.0 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 170.0 52.5 26.0 D 1.0 psi, 26.0 gprn 2A 170.0 51.5 26.0 Pipe: 3 0.0 0.0 2.00 150 0.3 2A 170.0 51.5 26.0 C L1.000 ---- 0.00 0.0 D 170.0 51.2 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device D 170.0 51.2 26.0 23 6.0 psi, .26.0 gprn C 170.0 45.2 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 170.0 45.2 21.0 2C L1.000 T: 7.0 7.00 0.0 23 170.0 43.9 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0.0 .0.0 2.00 150 0.2 2B 170.0 43.9 21.0 3A L1.000 ---- 0.00 0.0 2C 170.0 43.7 21.0 . 1.025 2.00 0.105 0.2 Pipe: 7 0.0 0.0 . 150.00 150 8.8 2C 170.0 43.7 21.0 3B 1.250 ---- 0.00 -2.6 3A 176.0 34.9 21.0 1.244 150.00 0.041 6.2 Pipe: 8 0.0 0.0 5.00 150 1.1 3A 176.0 34.9 21.0 3 1.250 ---- 0.00 -0.9 33 178.0 33.9 21.0 1.244 5.00 0.041 0.2 Pipe: 9 . 0.0 0.0 3.00 150 1.1 33 178.0 33.9 21.0 4 F1.000 ---- 0.00 -0.9 3 180.0 32.8 21.0 1.101 3.00 0.074 0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 180.0 32.8 21.0 5 A1.000 C: 5.0 5.00 -0.9 4 182.0 - . 30.9 21.0 1.049 7.00 0.142 1.0 Pipe: 12 0.0 13.7 5A 21.50 150 5.3 4 182.0 30.9 7.3 6 F1.000 3E:21.0 26.00 -1:7 5 186.0 25.6 21.0 1.101 B: 5.0 47.50 0.074 3.5 Pipe: 13 0.0 6.8 7 36.00 150 0.5 5 186.0 25.6 0.5 5A F1.000 23:10.0 10.00 0.0 6 186.0 25.2 7.3 1.101 46.00 0.011 0.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(1HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frrn Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 14.2 8 9.50 150 0.5 5 186.0 25.6 -0.5 6 F1.000 B: 5.0 5.00 0.0 5A 186.0 25.2 13.7 1.101 14.50 0.034 0.5 Pipe: 15 0.0 14.2 8 67.50 150 0.0 6 186.0 25.2 -13.7 5 F1.000 E:• 7.0 17.00 0.0 5A 186.0 25.2 0.5 1.101 2B:10.0 84.50 0.000 0.0 Pipe: 16 0.0 0.0 43.50 150 0.6 6 186.0 25.2 6.8 9 F1.000 E: 7.0 17.00 0.0. 7 186.0 24.6 6.8 1.101 2B:10.0 60.50 0.009 0.6 Pipe: 17 0.0 6.9 10 19.00 150 4.6 7 186.0 24.6 -0.1 9A F1.000 E: 7.0 12.00 -4.3 9 196.0 20.0 6.8 1.101 B: 5.0 31.00 0.009 0.3 Pipe: 18 0.0 14.1 10 11.00 150 5.2 5A 186.0. 25.2 0.1 9A F1.000 E: 7.0 12.00 -4.3 8 196.0 20.0 14.2 - 1.101 B: 5.0 23.00 0.036 0.8 Pipe: 19 0.0 0.0 92.00 150 . 0.0 8 196.0 20.0 0.1 9 F1.000 E: 7.0 22.00 0.0 9A 196.0 20.0 0.1 1.101 3B:15.0 114.00 0.000 0.0 Pipe: 20 . 0.0 6.9 10 . 0.50 150 0.0 9A 196.0 20.0 -6.8 7 F1.000 B: 5.0 5.00 0.0 9 196.0 20.0 0.1 1.101 5.50 0.000 0.0 Pipe: 21 0.0 0.1 9 5.00 150 0.0 11 196.0 20.0 -0.1 8 F1.000 B: 5.0 5.00 0.0 9A t96.0 20.0 0.0 1.101 10.00 0.000 . 0.0 Pipe: 22 0.0 0.0 4.00 150 0.0 102 196.0 20.0 0.0 F1.000 E: 7.0 7.00 0.0 11 196.0 20.0 0.0 1.101 11.00 0.000 0.0 Pipe: 23 0.0 0.0 4.00 150 0.0 101 196.0 20.0 0.0 F1.000 E: 7.0 7.00 0.0 11 196.0 20.0 0.0 1.101 11.00 0.000 0.0 Pipe: 24 0.0 . .21.0 103 14.50 150 0.7 8 196.0 20.0 -6.9 103 F1.000 B: 5.0 5.00 0.0 10 196.0 19.3 14.1 1.101 19.50 0.036 0.7 Pipe: 25 4.90 21.0 Disch 5.50 150 0.9 10 196.0 19.3 0.0 F1.000 E: 7.0 7.00 0.0 103 196.0 18.4 21.0 1.101 12.50 0.074 0.9 Pipe: 26 0.0 21.0 103 65.50 150 0.7 9 196.0 20.0 -14.1 8 F1.000 E: 7.0 7.00 0.0 10 196.0 19.3 6.9 1.101 72.50 0.010 0.7 NotE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(1HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) Calculations were performed by the HASS 8.5 computer program Under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.076 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation, report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HNC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D ,N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HNC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 3 (LOT 43) (2HD) 2526 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSJTY: .05 gpm/sq. ft. AREA OF APPLICATION: 244 sq. ft. COVERAGE PER SPRINKLER: 18X18'-324 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 34.0 gpm TOTAL WATER REQUIRED (including hose): 39.0 gpm FLOW AND PRESSURE (@ BOR) : 34.0 gpm @ 37.3 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. E 0 0 0 LC) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(2HD).SDF JOB TITLE: THE BLUFFS 0 N 0 0 0 0 (N 0 H 00 H H H (N 0 I W&)J01x1 -0U)H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(2HD).SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 119.5 105.0 500.0 119.4 39.0 91.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 39.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 170.0 SOURCE 91.5 39.0 2 170.0 - - - - 71.6 - - - 2A 170.0 - - - - 68.6 - - - D 170.0 - - - - 67.9 - - - C 170.0 - - - - 60.9 - - - 2B 170.0 HOSE STREAM 58.3 5.0 2C 170.0 - - - - 57.8 - - - 3A 176.0 - - - - 40.1 - - - 33 178.0 - - - - 38.8 - - - 3 180.0 - - - - 37.3 - - - 4 182.0 - - - - 34.1 - - - 5 186.0 - - - - 23.7 - - - 5A 186.0 - - - - 22.5 - - - 6 186.0 - - - - 22.5 - -,- 7 186.0 - - - - 20.3 - - - 8 196.0 - - - - 16.6 - - - 9 196.0 - - - - 14.9 - - - 9A 196.0 - - - - 14.4 - - - 10 196.0 - - - - 16.3 - - - 11 196.0 - - - - 12.6 - - - 101 196.0 K= 4.90 12.0 17.0 102 196.0 K= 4.90 12.0 17.0 103 .196.0 - - - - 16.3 - - - NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(2HD).SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 'l ' Source 0.0 45.00 150 19.9 1 170.0 91.5 39.0 2A K1.000 T: 6.0 7.00 0.0 2 170.0 71.6 39.0 0.995 G: 1.0 52.00 0.383 19.9 Pipe: 2 0.0 Fixed Pressure Loss Device 2 170.0 71.6 39.0 D 3.0 psi, 39.0 gpm 2A 170.0 68.6 39.0 Pipe: 3 0.0 0.0 2.00 150 0.7 2A 170.0 68.6 39.0 C 'Ll.00O ---- 0.00 0.0 D 170.0 67.9 39.0 1.025 2.00 0.332 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 170.0 67.9 39.0 2B 7.0 psi, 39.0 gpm C 170.0 60.9 39.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 170.0 60.9 34.0 2C L1.000 T: 7.0 7.00 0.0 2B 170.0 58.3 39.0 1.025 8.00 0.332 2.7 Pipe: 6 0.0 0.0 2.00 150 0.5 2B 170.0 58.3 34.0 3A L1.000 ---- 0.00 0.0 2C 170.0 57.8 34.0 1.025 2.00 0.257 0.5 Pipe: 7 0.0 0.0 150.00 150 17.6 2C 170.0 57.8 34.0 3B 1.250 ---- 0.00 -2.6 3A 176.0 40.1 34.0 1.244 150.00 0.100 15.0 Pipe: 8 0.0 0.0 5.00 150 1.4 3A 176.0 40.1 34.0 3 1.250 ---- 0.00 -0.9 3B 178.0 38.8 34.0 1.244 5.00 0.100 0.5 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 178.0 38.8 34.0 4 F1.000 ---- 0.00 -0.9 3 180.0 37.3 34.0 1.101 3.00 0.182 0.5 Pipe: 10 0.0 0.0 2.00 120 3.3 3 180.0 37.3 34.0 5 A1.000 C: 5.0 5.00 -0.9 4 182.0 34.1 34.0 1.049 7.00 0.347 2.4 Pipe: 12 0.0 21.9 5A 21.50 150 10.4 4 182.0 34.1 12.1 6 F1.000 3E:21.0 26.00 -1.7 5 186.0 23.7 34.0 1.101 B: 5.0 47.50 0.182 8.6 Pipe: 13 0.0 14.0 7 36.00 150 1.2 5 186.0 23.7 -1.8 5A F1.000 2B:10.0 10.00 0.0 6 186.0 22.5 12.1 1.101 46.00 0.027 1.2 NotE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN-3 (REV2)-LOT 43(2HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 20.0 8 9.50 150 1.2 5 186.0 23.7 1.8 6 F1.000 B: 5.0 5.00 0.0 5A 186.0 22.5 21.9 1.101 14.50 0.080 1.2 Pipe: 15 0.0 14.0 7 67.50 150 0.1 5A 186.0 22.5 -12.1 5 F1.000 E: 7.0 17.00 0.0 6 186.0 22.5 1.8 1.101 25:10.0 84.50 0.001 0.1 Pipe: 16 0.0 0.0 43.50 150 2.1 6 186.0 22.5 14.0 9 F1.000 E: 7.0 17.00 0.0 7 186.0 20.3 14.0 1.101 2B:10.0 60.50 0.035 2.1 Pipe: 17 0.0 23.8 9A 19.00 150 5.4 7 186.0 20.3 -9.9 10 F1.000 E: 7.0 12.00 -4.3 9 196.0 14.9 14.0 1.101 B: 5.0 31.00 0.035 1.1 Pipe: 18 0.0 9.9 10 11.00 150 5.9 5A 186.0 22.5 10.2 9A F1.000 E: 7.0 12.00 -4.3 8 196.0 16.6 20.0 1.101 B: 5.0 23.00 0.068 1.6 Pipe: 19 0.0 34.0 11 92.00 150 2.2 8 196.0 16.6 -23.8 9 F1.000 E: 7.0 22.00 0.0 9A 196.0 14.4 10.2 1.101 3B:15.0 114.00 0.019 2.2 Pipe: 20 0.0 34.0 11 0.50 150 0.5 9 196.0 14.9 -10.2 8 F1.000 B: 5.0 5.00 0.0 9A 196.0 14.4 23.8 1.101 5.50 0.094 0.5 Pipe: 21 0.0 17.0 101 5.00 150 1.8 9A 196.0 14.4 17.0 102 F1.000 B: 5.0 5.00 0.0 11 196.0 12.6 34.0 1.101 10.00 0.182 1.8 Pipe: 22 4.90 17.0 Disch 4.00 150 0.6 11 196.0 12.6 0.0 F1.000 E: 7.0 7.00 0.0 102 196.0 12.0 17.0 1.101 11.00 0.050 0.6 Pipe: 23 4.90 17.0 Disch 4.00 150 0.6 11 196.0 12.6 0.0 F1.000 E: 7.0 7.00 0.0 101 196.0 12.0 17.0 1.101 11.00 0.050 0.6 Pipe: 24 0.0 .0.0 14.50 150 0.4 8 196.0 16.6 9.9 9 P1.000 B: 5.0 5.00 0.0 10 196.0 16.3 9.9 1.101 19.50 0.018 0.4 Pipe: 25 0.0 0.0 5.50 150 0.0 103 196.0 16.3 0.0 P1.000 E: 7.0 7.00 0.0 10 196.0 16.3 0.0 1.101 12.50 0.000 0.0 Pipe: 26 0.0 23.8 9A 65.50 150 1.3 10 196.0 16.3 -14.0 7 F1.000 E: 7.0 7.00 0.0 9 196.0 14.9 9.9 1.101 72.50 0.018 1.3 NotE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 3 (REV2)-LOT 43(2HD).SDF JOB TITLE: THE BLUFFS NOTES (HASS) Calculations were performed by the I-lASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.007 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.1 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD1.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEli ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.244 1.81 3.62 1.21 4.22 3.62 0.60 6.03 6.03 3.62 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A P N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1:049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R K C G 45 El Tee RunT Kplg ChkVlv Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150. Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 4 (LOT 42) (1HD) 2530 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 194 sq. ft. COVERAGE PER SPRINKLER: 20X20-400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinkler TOTAL SPRINKLER WATER FLOW.REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR) : 21.0 gpm @ 32.0 psi SPRINKLER ORIFICE SIZE: 1/2' inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: 0 JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. E (D 0 0 Ln SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS—PLAN 4 (REV2)LOT 42(1HD) .SDF JOB TITLE: THE BLUFFS 0 0 )14 r- 0 0 0 0 0 00 00 10 c'J C I /DcnDc) —0uJH-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALC5\THE BLUFFS-PLAN 4 (REV2)LOT 42(1HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 119.5 105.0 500.0 119.4 26.0 59.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 170.0 SOURCE 59.8 26.0 2 170.0 - - - - 50.4 - .- - 2A 170.0 - - - - 49.4. - - - D 170.0 - - - - 49.1 C 170.0 - - - - 43.1 - - - 2B 170.0 HOSE STREAM 41.9 5.0 2C. 170.0 - - - - 41.7 - - - 3A 176.0 - - - - 34.1 - - - 3B 178.0 - - - - 33.1 - - - 3 180.0 - - - - 32.0 - - - 4 182.0 - - - - 30.1 - - - 5 186.0 - - - - 25.1 - - - 6 186.0 - - - - 23.9 - - - 7 196.0 - - - - . 19.8 - - - 8 196.0 - - - - 19.5 - - - 9 196.0 - - - - 19.4 - - - 10 196.0 - - - - 19.0 - - - 101 196.0 - - - - 19.0 - - - 102 196.0 - - - - 19.0 - - - 103 196.0 K= 4.90 18.4 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 42(1HD) .SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) NotE To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 . 45.00 150 9.4 1 170.0 59.8 26.0 2A K1.000 T: 6.0 7.00 0.0 2 170.0 50.4 26.0 0.995 G: 1.0 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 170.0 50.4 26.0 D 1.0 psi, 26.0 gprn 2A 170.0 49.4 26.0 Pipe: 3 0.0 0.0 . 2.00 150 0.3 2A 170.0 49.4 26.0 C L1..000 ---- 0.00 0.0 D 170.0 49.1 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device D 170.0 49.1 26.0 2B 6.0 psi, 26.0 gpm C 170.0 43.1 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 170.0 43.1 21.0 2C L1.000 T: 7.0 7.00 0.0 2B 170.0 41.9 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0.0 0.0 2.00 150 0.2 2B 170.0 41.9 21.0 3A L1.000 ---- 0.00 0.0 2C 17.0.0 41.7 21.0 1.025 . 2.00 0.105 0.2 Pipe: 7 0.0 0.0 120.00 150 7.5 2C 170.0 41.7 21.0 3B 1.250 ---- 0.00 -2.6 3A 176.0 34.1 21.0 1.244 120.00 0.041 4.9 Pipe: 8 0.0 0.0 5.00 150 1.1 3A 176.0 34.1 21.0 3 1.250 ---- 0.00 -0.9 38 178.0 33.1 21.0 1.244 5.00 0.041 0.2 Pipe: 9 0.0 0.0 3.00 150 1.1 38 178.0 33.1 21.0 4 F1.000 ---- 0.00 -0.9 3 180.0 32.0 21.0 1.101 3.00 0.074 0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 180.0 32.0 21.0 5 A1.000 C: 5.0 5.00 -0.9 4 182.0 30.1' 21.0 1.049 7.00 0.142 1.0 Pipe: 12 0.0 14.2 7 27.00 150 5.0 4 182.0 30.1 6.8 6 F1.000 E: 7.0 17.00 -1.7 5 186.0 25.1 21.0 1.101 2B:10.0 44.00 0.074 3.3 Pipe: 13 0.0 0.0 107.00 150 1.2 5 186.0 25.1 6.8 9 F1.000 E: 7.0 22.00 0.0 6 186.0 23.9 6.8 1.101 3B:15.0 129.00 0.009 1.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS -PLAN 4 (REV2)-LOT 42(lHD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T. Pf/ft. (Pf) Pipe: 14 0.0 0.0 . 11.00 150 5.3 5 186.0 25.1 14.2 8 F1.000 E: 7.0 17.00 -4.3 7 196.0 19.8 14.2 1.101 2B:10.0 28.00 0.036 1.0 Pipe: 15 0.0 9.0 10 10.00 150 4.5 6 186.0 23.9 -2:2 8 F1.000 B: 5.0 5.00 -4.3 9 196.0 19.4 6.8 1.101 15.00 0.009 0.1 Pipe: 15A 0.0 2.2 9 2.00 150 0.3 7 196.0 19.8 12.0 103 F1.000 B: 5.0 5.00 0.0 8 196.0 19.5 14.2 1.101 7.00 0.036 0.3 Pipe: 17 4.90 21.0 Disch 31.00 150 1.1 8 196.0 19.5 -9.0 F1.000 E: 7.0 12.00 0.0 103 196.0 18.4 12.0 1.101 B: 5.0 43.00 0.026 1.1 Pipe: 18 0.0 . 9.0 10 . 46.00 150 0.1 8 196.0 19.5 -6.8 6 F1.000 E: 7.0 12.00 0.0. 9 196.0 19.4 2.2 1.101 B: 5.0 58.00 0.001 0.1 Pipe: 19 0.0 0.0 6.00 150 0.0 102 196.0 19.0 0.0 F1.000 E: 7.0 12.00 0.0 10 196.0 19.0 0.0 1.101 B: 5.0 18.00 0.000 0.0 Pipe: 20 .0.0 0.0 8.50 150 0.0 101 196.0 19.0 0.0 F1.000 E: 7.0 7.00 0.0 102 196.0 19.0 0.0 1.101 15.50 0.000 0.0 Pipe: 21 4.90 21.0 Disch 37.00 150 0.7 10 196.0 19.0 -12.0 8 F1.000 B: 5.0 5.00 0.0 103 196.0 184 9.0 1.101 42.00 0.016 0.7 Pipe: 22 0.0 0.0 22.00 150 0.4 9 196.0 19.4 9.0 103 F1.000 B: 5.0 5.00 0.0 10 196.0 19.0 9.0 1.101 27.00 0.016 0.4 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.003 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Not€ INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 4 (LOT 42) (2HD) 2530 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 233 sq. ft. COVERAGE PER SPRINKLER: 18'X18'-324 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 34.6 gpm TOTAL WATER REQUIRED (including hose) : 39.6 gpm FLOW AND PRESSURE (@ BOR) : 34.6 gpm @ 39.7 psi SPRINKLER ORIFICE SIZE: 1/2' inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: • JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. E ia 0 0 LO SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 42(2HD).SDF JOB TITLE: THE BLUFFS 0 0 0 0 0 (N 0 ci, 0 0 (N 0 I 0(5N (14 W -Q4 U)-H-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 42(2HD).SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 119.5 105.0 500.0 119.4 39.5 91.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 39.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 170.0 SOURCE 91.8 39.5 2 170.0 - - - - 71.4 - - - 2A 170.0 - - - -. 68.4 - - - D 170.0 - - - - 67.7 - - - C 170.0 - - - - 60.7 - - - 2B 170.0 HOSE STREAM 58.0 5.0 2C 170.0 - - - - 57.5. - - - 3A 176.0 - - - - 42.5 - - - 3B 178.0 - - - - 41.1 - - - 3 180.0 - - - - 39.7 - - - 4 182.0 - - - - 36.3 - - - 5 186.0 - - - - 26.3 - - - 6 186.0 - - - - 22.9 - - - 7 196.0 - - - - 19.6 - - - 8 196.0 - - - - 19.0 - - - 9 196.0 - - - - 18.2 - - - 10 196.0 - - - - 16.2 - - - 101 196.0 K= 4.90 12.0 17.0 102 196.0 K= 4.90 12.8 17.5 103 196.0 - - - - 17.6 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTENS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 42(2HD).SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Note To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 45.00 150 20.4 1 170.0 91.8 39.5 2A K1.000 T: 6.0 7.00 0.0 2 170.0 71.4 39.5 0.995 G: 1.0 52.00 0.393 20.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 170.0 71.4 39.5 D 3.0 psi, 39.5 gpm 2A 170.0 68.4 39.5 Pipe: 3 0.0 0.0 . 2.00 150 0.7 2A 170.0 68.4 39.5 C L1.000 ---- 0.00 0.0 D 170.0 67.7 39.5 1.025 2.00 0.340 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 170.0 67.7. 39.5 2B 7.0 psi, 39.5 gpm C 170.0 60.7 39.5 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 170.0 60.7 34.5 2C L1.000 T: 7.0 7.00 0.0 2B 170.0 58.0 39.5 . 1.025 8.00 0.340 2.7 Pipe: 6 0.0 0.0 2.00 150 0.5 2B 170.0 58.0 34.5 3A L1.000 ---- 0.00 0.0 2C . 170.0 57.5 34.5 1.025 . . 2.00 0.265 0.5 Pipe: 7 0.0 0.0 . . .120.00 150 15.0 2C 170.0 57.5 34.5 33 1.250 ---- 0.00 -2.6 3A 176.0 42.5 34.5 1.244 120.00 0.103 12.4 Pipe: 8 0.0 0.0 5.00 150 1.4 3A 176.0 42.5 34.5 3 1.250 ---- 0.00 -0.9 3B 178.0 41.1 34.5 1.244 5.00 0.103 0.5 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 178.0 41.1 34.5 4 F1.000 ---- 0.00 -0.9 3 180.0 39.7 34.5 1.101 3.00 0.187 0.6 Pipe: 10 0.0 0.0 2.00 120 3.4 3 180.0 39.7 34.5 5 A1.000 C: 5.0 5.00 -0.9 4 182.0 36.3 34.5 1.049 7.00 0.358 2.5 Pipe: 12 0.0 22.5 7 27.00 150 10.0 4 182.0 36.3 12.0 6 F1.000 E: 7.0 17.00 -1.7 5 186.0 26.3 34.5 1.101 23:10.0 44.00 0.187 8.2 Pipe: 13 0.0 0.0 107.00 150 3.4 5 186.0 26.3 12.0 9 F1.000 E: 7.0 22.00 0.0 6 186.0 22.9 12.0 1.101 3B:15.0 129.00 0.027 3.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 42(2HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F. (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf). Pipe: 14 0.0 0.0 , 11.00 150 6.7 5 186.0 26.3 22.5 8 F1.000 E: 7.0 17.00 -4.3 7 196.0 19.6 22.5 1.101 2B:10.0 28.00 0.085 2.4 Pipe: 15 0.0 20.9 10 10.00 150 4.7 6 186.0 22.9 -8.8 8 F1.000 B: 5.0 5.00 4.3 9 196.0 18.2 12.0 1.101 . 15.00 0.027 0.4 Pipe: 15A 0.0 8.8 9 2.00 150 0.6 7 196.0 19.6 13.7 103 F1.000 B: 5.0 5.00 0.0 8 196.0 19.0 22.5 1.101 7.00 0.085 0.6 Pipe: 17 0.0 0.0 31.00 150 1.4 8 196.0 19.0 13.7 10 F1.000 E: 7.0 12.00 0.0 103 196.0 17.6 13.7 1.101 B: 5.0 43.00 0.034 1.4 Pipe: 18 0.0 20.9 10 46.00 150 0.9 8 196.0 19.0 712.0 6 F1.0.00 E:.7.0 12.00 0.0 9 196.0 18.2 8.8 1.101 B: 5.0 58.00 0.015 0.9 Pipe: 19 4.90 17.5 Disch 6.00 150 3.4 10 . 196.0 16.2 17.0 101 F1.000 E: 7.0 12.00 0.0 102 196.0 12.8 34.5 1.101 .B: 5.0 18.00 0.187 3.4 Pipe: 20 4.90 17.0 Disch .8.50 150 0.8 102 196.0 12.8 0.0 F1.000 E: 7.0 7.00. 0.0 101 196.0 12.0 17.0 1.101 15.50 0.050 0.8 Pipe: 21 0.0 34.5 102 37.00 150 1.4 103 196.0 17.6. -20.9 9 . F1.000 B: 5.0 5.00 0.0 10 196.0 16.2 13.7 1.101 42.00 0.034 1.4 Pipe: 22 0.0 34.5 102 22.00 150 2.0 9 196.0 18.2 -13.7 103 F1.000 B: 5.0 5.00 0.0 10 196.0 16.2 20.9 ' 1.101 27.00 0.074 2.0 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.007 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.3 ft/sec at pipe 1. Not€ INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 4 (LOT 50) (1HD) 2575 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 194 sq. ft. COVERAGE PER SPRINKLER: 20X20-400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 210 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR): 21.0 gpm @ 32.0 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY MASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC.. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(1HD) .SDF JOB TITLE: THE BLUFFS E la 0 0 In 0 44 -H U) 04 (D In Cl) cl) U) CD 04 E-4 0 0 III 0 0 0 0 0 • • • • 0 0 0 0 0 0 • r—i 00 10 (N 0 -QU) -H- --- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(1HD).SDF JOB TITLE: THE BLUFFS NFPA MATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.6 26.0 54.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 202.0 SOURCE 54.7 26.0 2 202.0 - - - - 45.3 - - - 2A 202.0 - - - - 44.3 - - - D 202.0 - - - - 44.0 - - - C 202.0 - - - - 38.0 - - - 2B 202.0 HOSE STREAM 36.7 5.0 2C 202.0 - - - - 36.5 - - - 3A 206.0 - - - - 34.1 - - - 3B 208.0 - - - - 33.1 - - - 3 210.0 - - - - 32.0 - - - 4 212.0 - - - - 30.1 - - - 5 216.0 - - - - 25.1 - - - 6 216.0 - - - - 23.9 - - - 7 226.0 - - - - 19.8 - - - 8 226.0 - - - - 19.5 - - - 9 226.0 - - - - 19.4 - - - 10 226.0 - - - - 19.0 - - - 101 226.0 - - - - 19.0 - - - 102 226.0 - - - - 19.0 - - - 103 226.0 K= 4.90 18.4 21.0 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(1HD).SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q.) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 45.00 150 9.4 1 202.0 54.7 26.0 2A K1.000 T: 6.0 7.00 0.0 2 202.0 45.3 26.0 0.995 G: 1.0 52.00 0.181 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 45.3 26.0 D 1.0 psi, 26.0 gpm 2A 202.0 44.3 26.0 Pipe: 3 0.0 0.0 2.00 150 0.3 2A 202.0 44.3 26.0 C L1.000 ---- 0.00 0.0 D 202.0 44.0 26.0 1.025 2.00 0.157 0.3 Pipe: 4. 0.0 Fixed Pressure Loss Device D 202.0 44.0 26.0 2B 6.0 psi, 26.0 gpm C 202.0 38.0 26.0 Pipe: 5 H.S. 5.0 Disch S 1.00 150 1.3 C 202.0 38.0 21.0 2C L1.000 T: 7.0 7.00 0.0 28 202.0 36.7 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0.0 0.0 2.00 150 0.2 28 202.0 36.7 21.0 3A L1.000 ---- 0.00 0.0 2C 202.0 36.5 21.0 1.025 2.00 0.105 0.2 Pipe: 7 0.0 0.0 16.00 150 2.4 2C 202.0 36.5 21.0 3B 1.250 ---- 0.00 -1.7 3A 206.0 34.1 21.0 1.244 16.00 0.041 0.7 Pipe: 8 0.0 0.0 5.00 150 1.1 3A 206.0 34.1 21.0 3 1.250 ---- 0.00 -0.9 3B 208.0 33.1 21.0 1.244 5.00 0.041 0.2 Pipe: 9 0.0 0.0 3.00 150 1.1 3B 208.0 33.1 21.0 4 F1.000 ---- 0.00 -0.9 3 210.0 32.0 21.0 1.101 3.00 0.074 .0.2 Pipe: 10 0.0 0.0 2.00 120 1.9 3 210.0 32.0 21.0 5 A1.000 C: 5.0 5.00 -0.9 4 212.0 30.1 21.0 1.049 7.00. 0.142 1.0 Pipe: 12 0.0 14.2 7 27.00 150 5.0 4 212.0 30.1 6.8 6 F1.000 E: 7.0 17.00 -1.7 5 216.0 25.1 21.0 1.101 28:10.0 44.00 0.074 3.3 Pipe: 13 0.0 0.0 107.00 150 1.2 5 216.0 25.1 6.8 9 F1.000 E: 7.0 22.00 0.0 6 216.0 23.9 6.8 1.101 38:15.0 129.00 0.009 1.2 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(1HD) .SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: - L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Fe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 11.00 150 5.3 5 216.0 25.1 14.2 8 Fl.000 E: 7.0 1.00 -4.3 7 226.0 19.8 14.2 1.101 2B:10.0 28.00 0.036 1.0 Pipe: 15 0.0 9.0 10 10.00 150 4.5 6 216.0 23.9 -2.2 8 F1.000 B: 5.0 5.00 -4.3 9 226.0 19.4 6.8 1.101 15.00 0.009 0.1 Pipe: 15A 0.0 2.2 9 2.00 150 0.3 7 226.0 19.8 12.0 103 F1.000 B: 5.0 5.00 0.0 8 226.0 19.5 14.2 1.101 7.00 0.036 0.3 Pipe: 17 4.90 21.0 Disch 31.00 150 1.1 8 226.0 19.5 -9.0 F1.000 E: 7.0 12.00 0.0 103 226.0 18.4 12.0 1.101 B: 5.0 43.00 0.026 1.1 Pipe: 18 0.0 9.0 10 46.00 150 0.1 8 226.0 19.5 -6.8 6 F1.000 E: 7.0 12.00 0.0 9 226.0 19.4 2.2 1.101 B: 5.0 58.00 0.001 0.1 Pipe.: 19 0.0 0.0 6.00 150 0.0 102 226.0 19.0 0.0 F1.000 E: 7.0 12.00 0.0 10 226.0 19.0 0.0 1.101 B: 5.0 18.00 0.000 0.0 Pipe: 20 0.0 0.0 8.50 150 0.0 101 226.0 19.0 0.0 F1.000 E: 7.0 7.00 0.0 102 226.0 19.0 0.0 1.101 15.50 0.000 0.0 Pipe: 21 4.90 21.0 Disch 37.00 150 0.7 10 226.0 19.0 -12.0 8 F1.000 B: 5.0 5.00 0.0 103 226.0 18.4 9.0 1.101 42.00 0.016 0.7 Pipe: 22 0.0 0.0 22.00 150 0.4 9 226.0 19.4 9.0 103 F1.000 B: 5.0 5.00 0.0 10 226.0 19.0 9.0 1.101 27.00 0.016 0.4 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080.621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.072 gprn. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Note INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEEI CA 92071 HYDRAULIC CALCULATIONS FOR THE BLUFFS PLAN 4 (LOT 50) (2HD) 2575 GLASGOW DRIVE CARLSBAD, CA 92010 FILE NUMBER: C6207 DATE: MAY 17, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR) SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RESIDENTIAL/LIGHT .05 gpm/sq. ft. 233 sq. ft. 18'X18-324 sq. ft. 2 sprinklers 34.6 gpm 39.6 gpm 34.5 gpm @ 37.9 psi 1/2" inch INNOVATIVE FIRE PROTECTION, INC. JOE PLASSMEYER CARLSBAD FIRE DEPARTMENT C-16 711148 CALCULATIONS BY BASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(2HD) .SDF JOB TITLE: THE BLUFFS a 0 0 0 IC) 0 In a 0 C LC) 0 0 0 0 0 0 0 0 0 0 0 (N 0 I —acn•H---- SPRINKLER SYSTEM HYDRAULIC ANALYSIS. Page 2 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)LOT 50(2HD) .SDF JOB TITLE: THE BLUFFS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. S DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 105.6 95.0 500.0 105.5 39.5 78.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 39.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 34.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 202.0 SOURCE 78.4 39.5 2 202.0 - - - - 58.0 - - - 2A 202.0 - - - - . 55.0 - - - D 202.0 - - - - 54.3 - - - C 202.0 - - - - 47.3 - - - 2B 202.0 HOSE STREAM 44.6 5.0 2C 202.0 - - -, - 44.1 3A 206.0 - - - - 40.7 - - - 3B 208.0 - - - - 39.3 - - - 3 210.0 - - - - 37.9 - - - 4 212.0 - - - - 36.3 - - - 5 216.0 - - - - 26.3 - - - 6 216.0 . - - - - 22.9 - - - 7 226.0 . - - - - 19.6 - - - 8 . .226.0 - - - - 19.0 - - - 9 226.0 - - - - 18.2 - - - 10 . 226.0 - - - - 16.2 - - - 101 226.0 K= 4.90 12.0 17.0 102 226.0 K= 4.90 12.8 . 17.5 103 226.0 - - - - 17.6 - - - NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS-PLAN 4 (REV2)-LOT 50(2HD) .SDF JOB TITLE: THE BLUFFS NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft). PT (q) Node/ Nom ID Eq.Ln. F (Fe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 45.00 150 20.4 1 202.0 78.4 39.5 2A 1<1.000 T: 6.0 7.00 0.,0 2 202.0 58.0 39.5 0.995 G: 1.0 52.00 0:393 20.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 202.0 58.0 39.5 D 3.0 psi, 39.5 gpm 2A 202.0 55.0 39.5 Pipe: 3 0.0 0.0 2.00 150 0.7 2A 202.0 55.0 39.5 C L1.000 ---- 0.00 0.0 D 202.0 54.3 39.5 1.025 2.00 0.340 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 202.0 54.3 39.5 2B 7.0 psi, 39.5 gpm C 202.0 47.3 39.5 Pipe: 5 H.S. 5.0 Disch 1.00 150 2.7 C 202.0 47.3 34.5 2C L1.000 T: 7.0 7.00 0.0 28 202.0 44.6 39.5 1.025 8.00 0.340 2.7 Pipe: 6 0.0 0.0 2.00 150 0.5 2B 202.0 44.6 34.5 3A L1.000 ---- 0.00 0.0 2C 202.0 44.1 34.5 1.025 2.00 0.265 0.5 Pipe: 7 0.0 0.0 . 16.00 150 3.4 2C 202.0 44.1 34.5 3B 1.250 ---- 0.00 -1.7 3A 206.0 40.7 34.5 1.244 16.00 0.103 1.7 Pipe: 8, 0.0 0.0 5.00 150 1.4 3A 206.0 40.7 34.5 3 1.250 ---- 0.00 -0.9 3B 208.0 39.3 34.5 1.244 5.00 0.103 0.5 Pipe: 9 0.0 0.0 3.00 150 1.4 3B 208.0 39.3 34.5 4 F1.000 ---- 0.00 -0.9 3 210.0 37.9 34.5 1.101 3.00 0.187 0.6 Pipe: 10 0.0 0.0 2.00 120 1.6 3 210.0 37.9 34.5 5 A1.000 ---- 0.00 -0.9 4 212.0 36.3. 34.5 1.049 2.00 0.358 0.7 Pipe: 12 0.0 22.5 7 27.00 150 10.0 4 212.0 36.3 12.0 6 F1.000 E: 7.0 17.00 -1.7 5 216.0 26.3 34.5 1.101 28:10.0 44.00 0.187 8.2 Pipe: 13 0.0 0.0 . 107.00 150 3.4 5 216.0 26.3 12.0 9 F1.000 E: 7.0 22.00 0.0 6 216.0 22.9 12.0 1.101 3B:15.0 ' 129.00 0.027 3.4 Note SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page.4 DATE: 5/17/2016 SYSTEMS\JP CALCS\THE BLUFFS -PLAN 4 (REV2)LOT 50(2HD).SDF JOB TITLE: THE BLUFFS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q$ Node/ Nom ID Eq.Ln. F (Pe) To Node . El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 11.00 150 6.7 5 216.0 26.3 22.5 8 F1.000 5: 7.0 17.00. -4.3 7 226.0 19.6 22.5 1.101 2B:10.0 28.00 0.085 2.4 Pipe: 15 0.0 20.9 10 10.00 150 4.7 6 216.0 22.9 -8.8 8 F1.000 8: 5.0 5.00 4.3 9 226.0 . 18.2 12.0 1.101 15.00 0.027 0.4 Pipe: iSA 0.0 8.8 9 2.00 150 0.6 7 226.0 19.6 13.7 103 F1.000 8: 5.0 5.00 0.0 8 226.0 19.0 22.5 1.101 7.00 0.085 0.6 Pipe: 17 0.0 0.0 . 31.00 150 1.4 8 226.0 19.0 13.7 10 F1.000 E: 7.0 12.00 0.0 103 226.0 17.6 13.7 1.101 B: 5.0 43.00 0.034 1.4 Pipe: 18 0.0 20.9 10 . 46.00 150 0.9 8 226.0 19.0 -12.0 6 F1.000 5: 7.0 12.00 0.0 9 226.0 18.2 8.8 1.101 B: 5.0 58.00 0.015 0.9 Pipe: 19 4.90 17.5 Disch . 6.00 150 3.4 10 226.0 16.2 17.0 101 F1.000 5: 7.0 12.00 0.0 102 226.0 12.8 34.5 1.101 B: 5.0 18.00 0.187 3.4 Pipe: 20 4.90. 17.0 Disch 8.50 150 0.8 102 226.0 12.8 0.0 F1.000 E: 7.0 7.00 0.0 101 226.0 12.0 17.0 1.101 15.50 0.050 0.8 Pipe: 21 0.0 34.5 102 37.00 150 1.4 103 226.0 17.6 -20.9 9 F1.000 B: 5.0 5.00 0.0 10 226.0 16.2 13.7 . 1.101 42.00 0.034 1.4 Pipe: 22 0.0 34.5 102 . 22.00 150 2.0 9 226.0 18.2 -13.7 103 F1.000 B: 5.0 5.00 0.0 10 226.0 16.2 20.9 1.101 27.00 0.074 2.0 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 . granted by HRS Systems, Inc. - 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.015 gpm. . Total pressure at each node is used in balancing the system. Maximum water velocity is 16.3 ft/sec at pipe 1. Not € '-C-. P. .jPage 1 of 8 SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 I-u GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar12) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. AS 160115 2535 GLASGOW DR Document No. U085160 Date Feb/09/2015 OPERATION Page 2 of 8 2- 46 (0 52mm) NPT1/2 Marking No. Year of Manufacture SIN SS8464 K-factor <4.9 1/—Lot Roling : 162F/72C UL Mark or75F/79C Temperature r Control No. : 6P37 ji NSF Mark: Nsr- sl --G RES SPKR ® Body (Copper Alley) Deflector (Phosphorus Bronze) CD Gasket (PTFE) _________________ ® Fusible Metal (Solder) t Heat Collector (Copper) 2- °/e" (0 68mm) 6 Cover Plate Assembly or 3-Y4" (83mm) or 2- °/8"square (068mm) FIGURE 1. Model RC-RES K4.9 Color Code Color -SIN SS8464 K-toclor: e4.9 Temperature Rating: 6zrfl2c or 175F/79C COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) TECHNICAL DATA Approvals:,UL,,, Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (112.1 bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPM/psi112 (70.6 LPM/bar112) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (72°C): Uncolored 1751 (790C): White Color Code (Cover Plate) 140°F (600C): No Mark 1621 (720C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the C o v e r P l a t e i s released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire , a n d when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the w a t e r f l o w to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation =# Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No. U085160 Date Feb/09/2015 Page 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 130, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 130 or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of 'design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date Feb/09/2015 Page 4 of 8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the design area' comprised of the four most hyd r a u l i c a l l y demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Maximum Ordinary Intermediate Covera ge Maximum Temperature Rating Temperature Rating Deflector Minimum Spacing 162'F (72°C) 175F (79°C) Installation Spacing Area 1 Ft. x Ft. Ft. to Ceiling Type Ft. Flow Pressure (b) Flow xm) (m) GPM GPM (m PSI (LPM) (bar) Fer)e (LPM) Smooth 12x12 12 13 7.0 13 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) 3/8 to 7/8 Inches. 14x14 14 13 7.0 13 7.0 Beamed (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R Concealed 8 (4.9x4.9) (4.9) . (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 18X18 18 17 12.0 18 13.5 . 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 below (6.1x6.1) (6.1) (79.5) (1.27) - - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for th e Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 E d i t i o n o f NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go bey o n d t h e coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprink l e r s w h i c h show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minim i z e t h e potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is co m p l e t e d . T h e Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date Feb/09/2015 Page 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in. Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installina Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make o Space Here Do NOT /we. ) (6.4mm) I Over-Tighten Groove on the Sprinkler Mn )' (3.2mm) Tolerance Limit Protective Cop of Mountino Surface _____ ___ Groove of the Socket fCeiling Mounting Surface/ (6Omm) Ceiling Hole Diameter Socket I CORRj IINCORRECT1 FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date Feb/09/2015 Page .• 6 of Sprinkler :Head: M Prote ctive Step I Remover RC Step 2 Hook by turning Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Document No. U085160 Date Feb/09/2015 CARE AND MAINTENANCE Page :7of 8 The following instructions must be implemented for the maintenance and service of the Model.RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 t to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve mustbe obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any,sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100'F/38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A 'Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U085160 Date . Feb/09/2015 Page 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the'following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F '(79°C)) Cover Plate Assembly: 2-5/8 inch (q5 68mm) or 3-1/4 inch (0 83mm) or 2-5/8 inch square (08mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 '- - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date Feb/09/2015 Conventional Recessed Pendent/Fl/F2 Recessed PendentjFP Bulletin 014 Rev. N liable Model Fl FR Series Quick Response Glass Bulb Sprinklers C CD 0 CD PIA Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus). FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA 1425) 0786-CPD-40252 (RA 1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall XLH Upright XLH Pendent Pendent Fl/F2 Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. - ..- :-_ ;;- :.•:- Concealed Pendent Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12,7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1 Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs'for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FRS6LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NFl standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench mm SIN List in gs and Approvals Approval Notes US Metric inches mm inches Fl FR28 2.8 40 3/8 10 Pendent 2.25 57 0 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA141 1 cULus 2 Upright 2.25 57 0 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 0 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA14181 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (Fl FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D. RA1423 us cULus 1,2 F1FR56 5.6 80 ______ 1/2 15 Pendent 2,25 57 0 RA1414 FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent _______________ 2.25 _____ 57 GFR2 _________ RA1414 ______ cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 0 RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 1 57 RC1 RA14141 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 _______ cULus, FM, LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. 0 cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. 3) Available with FM approved Polyester coating in black or white. '" Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (680c) temperature rated sprinklers only. VdS approved sprin- klers must use Norbuib brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. °) Model Fl F856 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. ° cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. 0 The F1FR56 Vertical Si dewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector! Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 1350F(57°C) Temp. Rating 155°F(680C) Temp. Rating 1750F(79°C) Temp. Rating 200°F(93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus -- _________ Upright cULus Pendent VdS F1FR40 Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus I -- __________ Upright cULus Pendent -- cULus, NSF -- F1FR42LL _________ Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- __________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- F1FR56 Concealed Pendent* cULus cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright) LPCB VdS EC Pendent -- cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- _________ Concealed Pendent" -- cULus, NSF -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM -- F1FR56 I Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA 1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS,EC _ F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 FIFR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F? ESCUTCHEON AT MAXIMUM RECESS = 1[25.4mm] AT MINIMUM RECESS = 3/8[9.5mm] / F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4[19mm] AT MINIMUM RECESS = 3/8[9.5mm] Fl ESCUTCHEON AT MAXIMUM RECESS = 7/8"(22.2mm] [32mm] I / AT MINIMUM RECESS = I - 5/8 '[41.3mm] r F2 ESCUTCHEON AT MAXIMUM RECESS = 1-l/8"[28.6mm] AT MINIMUM RECESS = 1-5/8[41.3mm] 2 1/4' HOLE 01,4. [57.2mm] I 15/16" 0/A [49.2mm] ' 1 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH Boss Fl ESCUTCHEON j_ .314't 19mm] ADJUSTMENT F2 ESCUTCHEON 7/2[12.7mm] ADJUSTMENT 2 27/32" 0/A. (72.2mm] Fig.1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon T 2 5/8" 0/A. [66,7mm] HOLE IN CEILING / 2 5/16" DIA. [58.7mm] - CUP CEILING 1" X 1/2" REDUCER FACE OF FI177NG TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2 "[38mm] AT MINIMUM RECESS = 1 "[25.4mm] Y2"[12. 7mm] 47 MAXIMUM RECESS = 9/16"[14,3mm] AT MINIMUM RECESS = / "[25.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Fig.2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. 1 1/2" MAX. FACE OF FITTING _HTO FACE OF CEILING DIMENSION Fl ESCUTCHEON T AAAV!AAIIAA p,"ç 1_ AIR "T4 Q,,,,-,,7 AT MINIMUM RECESS = 2- 16"[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8."[4 1.3mm] 1/8" AT MINIMUM RECESS = 2-1/16 "[52.4mm] 2mm] I (j) 4"-12" [101.6mm-304.8mm] 32 DIA CEILING TO [72.1mm] DEFLECTOR F! ESCUTCHEON 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'[12. 7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8 "[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE 0/A. [5 7.2mm] 1" X 1/2" REDUCER I - I I 15/16" [49.2mm] Ii I I - TURN COLLAR UNTIL --- TIGHT AGAINST SPRINKLER WRENCH BOSS. Ol/VOJE RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW Ef1 +Ih1 } 2 5/8" DIA. 2 5/16" 0/A - 7 17OLE IN CEILING CUP CEILING -" 1/2" MAX. I COVER ADJUSTMENT COVER PLATE -7 ASSEMBLY 5/16 0/A SPRINKLER CONCEALED, 1/2" ADJUSTMENT Fig. 4 Model Fl FR56/1`1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate Ll- 1" x TEE 1/2" REDUCING OR ELBOW T1If1r 2 /8" 0/A. IN CEILING 1 1/2' MAX. FACE OF FITTING . TO FACE OF CEILING , DIMENSION CEILING 5/16" COVER ADJ COVER AS. 3/4" -r SPRINKLER .CONCEALED, "f 6" ADJUSTMENT 017F502A Fig. 5- Model Fl FR56IF1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platet" Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated )4))5X6i White Painted Special Application Finishes Sprinkler Escutcheon Cover platet Electrofess Nickel PTFE 7t Electroless Nickel PTFE Bright Brass rig Bright Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(20) Black Paint Off White Off White (2X6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. (1) cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(vsw), RA1425 (upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent][ Upright] [Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][lSO 7-Rl/2] Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F(57°C)for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled Rr'll a b I (800) 431-1588 Sales Offices Pape (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices - www.reliablesprinkler.com Internet Address EG. Printed inU.S.A. 12/15 P/N9999970300 Fl Res 30, 49, 58 & 76 Fl Res 30,49,58&76 Recessed Pendent I Fl Recessed Pendent! FP Bulletin 135 Rev. M Model Fl Residential Sprinklers for Design Density of .05 gpm1ft2 ED C (11 c) 01 (0 CR Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm1ft2 Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/Fl Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed. Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent Fl Res 76 CCP Pendent Fl Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Fl Res 44 & 58 Fl Res 44 SWC Recessed HSW/F2 Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2' NPT (R'/2) K-Factor: 3.0 (432) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Fl Res 30, 49, 58 & 76 CCP Pendent Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2, Data: the only recessed escutcheons to be used with ModelF1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment Inch (mm) "A" Inch (mm) Face of fitting to ceiling Inch (mm) B Deflector Distance below bottom of beam Inch (mm) Fl (19.0) Mm. Recessed = 1/8 (41.3) /8 (9.5) 13/,(44.4) Max. Recessed = /8 (22.2) 11/8 (28.6) 1(25.4) 1/2 (12.7) Min. Recessed = 1/8 (41.3) (9.5) 13/-(44.4) Max. Recessed = 1/8(28.6) /a (22.2) 11A(31.7) 'Note: Escutcheons El or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent / F2 Model El Res 30, 49. 58 & 76 Pende P --I-i nt • Mod I i-i iies 4. bu & i'ti iiecessea i-'en lent /Fi IJ5F'COJ 1-1 escutcheon, /4 (19mm) adjustment [57.2mn)-.. I I5/I6 01.4. II [492 m] — TICHT AGAINST SPRINKLER 21/4' HOLE 0/A - REDUCER 2 FACE OF FITUNG TO TURN COLLAR UNTIL WRENCH BOSS. CEILING DIMENSION: K 1/ 3/8W-I 1/8" (Fl ESCUTCHEON) 318"-718" (P2 ESCUTCHEON) ADJUSTMENT W. 2 27/32' 0/A. [722 Hg. 1 Fig. 2 Technical Data: Fl Res 30 Pendent and Recessed Pendent (SIN R351 1) I Thread Size I Nominal Orifice Inch (mm) Max. Pressure psi (bar) I Sprinkler Temp. Rating I Max. Arn ientTemp.1 Actual K Factor I Sprinkler Length Inch (mm) I OF I °C I OF °C Y2"NPT I (R½) 21/" (8.2) 175 (12) I I 155 175 68 I 79 I 100 38 3.0(43.2) 2.25 (57) Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing (1550 80c) (175°F/790 ) Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (tlmin) PSI (bar) GPM (Llmin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3.6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth Ceilings 1¼104(31.7t0 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/4 to 1/4 (31.710 44.4) using F2 escutcheon 8(2,4) 16 X 16(4,9 X 4,9) 16(4,9) 13(49) 18.8(1,3) 13(49) 18.8(1,3) I-or Uefflng types reter to NI-I-/A 13, 13H or 13U 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) I Thread FNominal Orifice Max. Sprinkler Max. I Actual I Sprinkler 1 Size Inch (mm) Pressure Temp. Rating Ambient Temp. K Length cc I OF °C I psi (bar) Factor I Inch (mm) ½"NPT (R½) I /16" (11) 175 (12) I 155 I 175 68 79 J 100 150 I I 38 66 I I 4.9(70.6) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (1550Fi8°C) (175°F/790C) Top of Deflector Minimum Ft x Ft (m x m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (L/min) PSI (barL GPM (L/min) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13(49) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7.0 (0,48) 13(49) 7.0(0,48) 1 to 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0 (0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17 (64,3) 12(0,83) 17(64,3) 12 (0,83) beams 11/4 to 13A (31.7 to 14.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7 (1,14) 20(75,7) 16,7(1,14) to 1/4 (25.4 t044.4) using Fl _____ escutcheon For Ceiling types refer to NFPA 13, 13R or 130 Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (l55°F,8°C) (175°F'790C) Top of Deflector Minimum FtxFt(mxm) . Ft(m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (11mm) PSI (bar) GPM (Llhiin) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4 (0,65) 15(57) 9.4 (0,65) Smooth Ceilings 4 to 8(100 to 203) using F2 escutcheon. 14 X 14 (4,3 x 4,3) 14(4,3) 16(60.5) 10.6(0,73) 16(60,5) 10.6 (0,73) 4 to 8(100 to 203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0 (0,83) 17(64,3) 1 12.0(0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 to 8(108 to 203) using F2 escutcheon, 4 to 8(100 to 203) 20 x 20(6,1 x 6,1) 20(6,1) 22(83,2) 20.2 (1,4) 22(83,2) 20.2 (1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread I Nominal Orifice I Max.p I Sprinkler S I Max. I I Actual Sprinkler Size Inch (mm) Pressure pTemp. Rating i Ambient Temp. K Factor Length OF °C OF I psi (bar) Inch (mm) ½" NPT (R'/2) I ½" (13) 1 175 (12) j 155 175 68 79 I 100 I 150 38 66 5.8 (83.5) I 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (155°Fit8) (175°F179°C) Top of Deflector Minimum Ft Ft (m x m) Ft(rn) to Ceiling Spacing Flow Pressure Flow Pressure GPM (Llmin) PSI (bar) GPM (Llmin) PSI (bar) Inch (mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) Smooth Ceilings 1114 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 130, I3A or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) 19(72) 10.8 (0,75) 11/4 to 1/4 (31.7 to 44.4) using F2 escutcheon, 1 t 13/4 (25.4 to 20 x 20 (6,1 x 6,1) 20(6.1) 22( 83,3) 14.4(1,0) 22 (83,3) 14.4 (1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3. Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. I Sprinkler I Max. K Sprinkler Size Inch (mm) I Pressure Temp. Rating Ambient Temp. Factor Length I °C I OF I °C psi (bar) I Inch (mm) NPT "/32" (13.5) 175(12) I 155 68 100 I 38 I 7.6(109) J 2.25 (57) 175 I I 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (1 55°F/8°C) (11750 90C) Top of Deflector to Ceiling Flow Pressure Flow GPM Pressure Ft x Ft (mx m) Ft (m) Inch (mm) Spacing Ft GPM (Llmin) PSI (bar) (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) Smooth Ceilings 41/4 to 8(108 to 203) using F2 escutcheon. 14 X 14 (4,3 X 4,3) 14(4,3) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) 4 to 8(100 to 203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (053) Beamed Ceilings per NFPA 130, 13R or 13 installed in 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 21(79,5) 7,6 (0,53) 21(79,5) 7.6 (0,53) beams 414 to 8(108 to 203) us- ing F2 escutcheon, 4 to 8(100 20 x 20(6,1 x 6,1) j 20(6,1) 23(87,1) 9.2 (0,63) 23(87,1) 1 9.2 (0,63) to 203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 Model Fl Res 30, 49, 58 & 76 CCP Pendent* * Not listed for corrosion resistance. CEILING CUP 1".112" REDUCER CUP MAX. FACE OF FITTINGJ TO FACE OF CEILING DIMENSION COVER ADJUSTMENT HEIGHT 3 5/16 0/A. 135FG04E [84. 1mm] Fl RES 30, 49. 58 & 76 CCP PEND. Fig. 3 Note: The Fl Res 76 will use a 1" x 3/4" reducer. CCP Cover Plate Data: "A" Cover Adjustment "B" CCP Height "C" Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2(12.7) '/16 (24) 112 (13) - 1(25.4) /16 (7.9) 3/4 (19) 1 1/2 (13) - 1 (25.4) ' Model Fl Res 30, 49, 58 & 76 FP push-on/thread-off escutcheon 2 5/8" 0/A. [66.7mm] -HOLE IN CEILING - 2 5/16" 0/A. - [58.7mm] - CUP - i' X 1/2' REDUCER CEILING I 1/2" [38 1mm] MAX 01, FACE OF FITTING TO / FACE OF CEILING "a" El RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: "B" "A" Deflector Distance below bottom FP Position Inch (mm) of beam Inch (mm) Max. Recessed /6(11) Y2(12.7) Mm. Recessed '5/16(24) 1 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4 Technical Data: Fl Res 30 CCP Pendent and Recessed Pendent/FP (SIN R351 1) Nominal Max. CCP Assembly Max. K Sprinkler I Orifice j Pressure I Temp. Rating i Ambient Temp. Factor Length °F I °C °F I °C LThread Inch (mm) psi (bar) Inch (mm) I I 21//' (82) 175(12) 135 57 100 38 3.0(43.2) 2.25(57) Ordinary Temp. Rating Max. Coverage area Max. Spacing (155°F/68°C) lop of Deflector to Ceiling Minimum Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Flow Pressure GPM (lJmin) PSI (bar) Ft (m) 12 X 12 (3,6 X 3,6) 12(3,6) 8(30,3) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using COP. '/2 to 1(13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 11(37,8) 13.4(0,92) beams 1/2 to 1(13 to 25.4) using COP. ½ to 1(13 to 25.4) using FP escutcheon. For Ceilino Woes refer to NFPA 13. 13R or inn Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal CCP Max. I Thread Orifice Max. Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp . Fact or Length (mm) psi (bar) Rating Inch (mm) OF oC OF IOC ½' NPT (R½) /6" (11) 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum Max. Spacing (155' 80C) lop of Deflector to Ceiling area Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Ft (m) Flow Pressure GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(131025.4) using 14 x 14 (4,3 x 4,3) 14(4.3) 13(49) 7.0 (0,48) COP. ½ to 1(13 1025.4) using FP escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 14 (53) 8.2(0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(131025.4) using 8(2.4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5 (0,93) COP. 1/2 to 1(131025.4) using FP escutcheon. 20 x 20(6,1 x 6,1) f 20(6,1) 20(75,7) 16.7 (1,14) For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread Nominal Max. I I CCP Assembly I Max. I K Sprinkler Size Orifice Pressure I Temp. Rating I Ambient Temp. Length I Inch (mm) I psi (bar) , I OF , I °C i I OF , I °C I Factor I I Inch (mm) (R½) I /2" (13) I 175 (12) I 135 I I 57 100 38 I 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum Max. Spacing (155' 80C) Top of Deflector to Ceiling area Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Flow Pressure GPM (L/min) PSI (barL Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings ½ to 1(131025.4) using OCR 112 to 1(13 to 25.4) using FR escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using COP. 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 130 5, Escutcheon, F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) I Inch (mm) F2 ______ 1/2 (13) /16 - (4.7-17.4) Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal I I CCP Assembly I Max. Sprinkler Size I Pr KOrifice Temp. Rating Ambient Temp. Length (mm) p A(12) °F IInch °C I °F °C Inch Factor (mm) 3/4W NPI /32" (13.5) 1 135 57 I 100 150 38 66 7.6(109) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°F/68°C) lop of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 21(795) 7.6 (0,53) Smooth Ceilings 1/2 to 1(13 to 25.4) using OCR 1/2 to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 21 (79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using COP. 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 22(83,3) 8.4 (0,58) ½ to 1(13 to 25.4) using FP escutcheon. 20x 20(6,1 x 6,1) 20(6,1) 25(94,6) 1 10.8 (0,74) -or Ceding types reter to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW 35/006-0 I I 15/16" 0/A. 1,1 Ii (49.2mm] 2 1/4' HOLE OIA. [57.2mm) I" X 1/2" REDUCER TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH SOSS. F02_7~"~2 FACE OF FITTING To - WALL DIMENSION I 7- Fl RES 58 & 44 HSW/F2 1/8 [3 2mmJ I H 1/2" [13mm] ADJUSTMENT 1 1/4" MIN. [31.8mm] I 4'. CEILING TO DEFLECTOR IMENSION 2 27/32" 0/A. [72.2mm] Fig. 5 F2 escutcheon, 1/2" (13mm) adjustment Model Fl Res 44 & 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal I Max. Sprinkler I Max. I Ambient K I Sprinkler Size I Orifice I Pressure I Temp. Rating I i I Temp. Factor I Length Inch (mm) psi (bar) I Inch (mm) 1°F I 0FI0C Y2' NPT I (R½) /e" (10) 175 (12) I 155 100 1175 150166 E79 38 4.4(63) 2.45 (62) on m ,.....-, Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F179°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Ft (m) Flow GPM (1/mm) Pressure PSI (bar) Flow GPM (1/mm) Pressure 12 x 12 (3,6 x 3,6) 12(3.6) 12 (45,4) 7.5(0,52) 12(45,4) 7.5 (0,52) 4 to 6(100 to 152): Y2(13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 16(60,6) 13.3(0,92) 16(60,6) 13.3 (0,92) 16 X 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8 (1,16) 18(68,1) 16.8(1,16) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7 (1,29) 19(72,0) 18.7(l.29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) 12 x 12 (3,6 x 3,6) 12(3,6) 14 (53,0) 10.2(0,71) 14(53,0) 10.2 (0,71) 6t0 12 (152 to 305): 1/2 (13)recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,6) 13.3 (0,92) , 16(60,6) 13.3 (0,92) 16 x 16(4,9 x 4,9) 16(4.9) 17(64,4) 15.0(1,04) 17 (64,4) 15.0(1,04) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,7) 20.7(1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27,4 (1,89) 23(87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: Fl Res 58 HSW & HSW/F(SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler Max. Sprinkler Face of Fitting Adjustment Thread Orifice to wall Pressure Temp. Rating Ambient K Length Type Inch (mm) Size Inch psi (bar) Temp. Factor Inch Inch (mm) (mm) OF I °C OF I °C (mm) ______ /16 - 11/16 /2' NPT 155 68 100 38 F2 V2(13) 1/2"(13) 175 (12) 5.8 (83.5) 2:45 (62) (4.7 17.4) (R/2) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (1550F/68°C) (175°F179°C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Llmin) PSI (bar GPM (L/min) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3.6) 16(60,6) 7.6(0,53) 16 (60,6) 7.6(0,53) 4 to 6(100 to 152): 14 x 14(4,3 x 4,3) 14(4.3) 18(68,2) 9.7(0,69) 18 (68,2) 9.7(0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2(0,91) 21(79,5) 13.2 (0,91) ½ (13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(l.28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0 (1,73) 29(109,8) 25.0(1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 12 (152 to 305): 1/2 (13)recessed 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4 (1,0) 22(83,3) 14.4(1,0) 16 x 16(4,9 x 4,9) ' 16(4,9) 26(98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 31(117,4) 1 28.6 (1,97) 1 31(117,4) 1 28.6 (1,97) :or Ceiling types refer to NFPA 13, 13R or 13D 7. Model Fl Res 44 SWC* * Not listed for corrosion resistance. --7 4' 4" to 12' (l01.60rno To 1/4" (3I.75rn,,,J M04,rn,m - 304. P* Of Fltt,ng To Wo6 OH,ons,on PUSH ON COVER. 114tH I TURN TO ADJUST UNTIL R 1 flGHI AGAINST WALL. IX I/2 Rod0000 - Roo,noodod I We//HOI 2 5/8 2 5/I6 [66.68mm) Ojo. - TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH ROSS. trr .s 5/I6 I (84.4mm] 0,0. I - /2" (12.70mm) A8jo0tm.flt Ft RES 44 swc Fig. 6 Tprhnir"il floits 1:1 Poe 1101 cwc IQIKI Nominal Max. Cover Max. I i Sprinkler Thread Orifice I I Pressure Temp. Ambient K Length Size Inch (mm) I I psi (bar) Rating Temp. Factor Inch (mm) °F I 0C OF '/"NPT I (R½) 3/8" (10) 175 (12) 135 57 100L38 4.4 (63) 2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (1/mm) Pressure 12 x 12(3,6 x 3,6) 12(3,6) 13 (49,2) 8.7(0,60) 4 to 6(100 to 152): 1/2 (13)recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4.3) 14(53,0) 10.2(0,71) 16 x 16(4,9 x 49) 16(4,9) 17(64,3) 15.0(1,1) 16 x 18 (4,9 x 5,5) 16(4,9) 19(71,8) 18.7(1,13) 16 x 20 (4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2 (0,71) 6 to 12 (152 to 305); 72 (13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4,3) 15(56,7) 11.7(0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8(1,16) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D Mr'idgI WccR I.IQWV (I inirl Technical Data: F1 Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler I I Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating ________________________ Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) I °F Number (SIN) I °C Bulb Y2"NPT 1/2 (13) 175 (12) 155 175 79 68 I 100 150 66 38 5.8 (83.5) 2.45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/680C) Intermediate Temp. Rating (1750F/79°C) Top of Deflector to Ceiling Inch (mm) Spacing I Minimum Ft( m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (11mm) Pressure PSI (bar) 18x20(5,5x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26,8(1,85) 4t06(100to 152); ½ (13) recessed using F2 escutcheon 8(2.4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4.9) 33(125) 32.4 (2,23) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 42(160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); 112 (13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4 (3,6) 42(160) 52.4 (3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Mnrfr.I Fl R I4WY (Ri,Ih FACE OF F/ri/NC To WALL DIMENSION 2 1/4" HOLE 0/A. [57.2mm] I" X 1/2" REDUCER TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH ROSS. JSFGO8 L2m I 11/16" U/N. (31 8mm] ' CElL/NC TO DEFLECTOR OwENSION 2 27/32" 0/A. [72.2mm] 1/2" [/3mm] ADJUSTMENT Fl RES 58 HSWX Fig. 7 I Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) OF I0C Link ½" NPT /2" (13) 175(12) 100 (R 112) 38 5,8 (83.5) 2.45 (62) RA3593 Ordinary Temp. Rating Max. Coverage area Max. Spacing (165- VC) Top of Deflector to Minimum Ft x Ft (m x m) Ft (m) Ceiling Spacing Flow Pressure GPM (1/mm) PSI (bar) Inch (mm) Ft (m) 18 x 20 (5,5 x 6, 1) 18(5,5) 29(109) 25(1,72) 4 to 6(100 to 152): 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(l.85) 16 x 22 (4,9 x 7,3) 16(4,9) 33(125) 32.4 (2,23) ½ (13) recessed using F2 escutcheon 16 x 24 (4,9 x 7,3) 16(4.9) 38(144) 42.9(2,96) 8(2,4) 14 x 26 (4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) Recessed 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4 (3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4.3) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-F)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for FiRes 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58, SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/171, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent( FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded "DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjustment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½' adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/Fi] [Model El Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-F)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½' NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon" coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model El Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 34" NPT thread. Wa- ter seal assembly shall consist of a Teflon" coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). p *DuPont Registered Trademark ,., .-. Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NFl thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/1t2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having -;.- .... a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1 F2 FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright chrome Plated chrome White and Black White Painted Polyester(l) coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon 2' Electroless Nickel PTFE (Tellon®) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull chrome Dull Other finishes and colors are available on special order. Consult factory for details. cULus listed corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and properly for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United Slates, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Reliable (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/15 P/N 9999970235 ZURN Model. 950XL JLKINS Double Check Valve Assem AS 160115 2535 GLASGOW DR Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) o C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern Cali- fornia (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2) NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NoryITM, NSF Listed Springs Stainless steel, 300 series Options (Suffixes can be combined) - with full port QT ball valves (standard) Li L - less ball valves F1 U - with union ball valves S - with bronze "Y" type strainer fl TCU - with test cocks "vertical up E] V - with union swivel elbows (3/4" & 1") Li OSY - with OS & V gate valves fl FDC - with fire hydrant connection (2" only) fl FT - with integral male 45° flare SAE test fitting PF - with Z-BiteTM push fit connections* (1/2-1 "only) I PR - with ZPressTM press fit connections" *Fittings ship in box with valve and must be threaded into valve by hand on site. Accessories Repair kit (rubber only) Features El Thermal expansion tank (Model XT) Sizes: 3/4", 1", 1 1/2", 2 F1 QT-SET Quick Test Fitting Set Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131 .20.1 tC E 13- DH__ G - Dimensions & Weights (do not include pkg.) DIM ENSIONS_(aoproximate) WEIGHT MODEL A UNION B LESS BALL LESS WITH SIZE A BALL VALVES C D E F G BALL BALL VALVES VALVES VALVES in. mm in. 'mm in. I mm in. imm in. imm in. Imm in. mm in. Imm in. mm Us jg 3/4 20 111/4 286 121/2 1318 7 178 11/2 38 1/2 89 3 76 15 381 5 2.3 7 3.2 1 25 121/4 311 137/8 353 7 178 11/2 38 31/2 89 3 76 173/4 451 8 3.6 12 5A 11/4° 32 151/2 419 18 1/2 470 109/16 268 2 51 3J94 31/1/2 114 41/2 114 211/2 546 16 7.3 22 10 11/2 40 171/8 435 191/8 486 109/16 268 2 51 31/0 2 50 181/4 4601 20 5081 109/16 2681 2 51 31//2 114 41/2 114 25 1/8 638 *Size 1-1/4" Discontinued Zurn Industries, LLC I Wilkins Rev. 0 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 4/15 In Canada Zurn Industries Limited Document No. BF-950XL 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Product No. Model 950XL .1-._X-,n I Page 1 of 2 Flow Characteristics 0 Raid Flow (esablishcd by approval agcncic0 MODEL 950XL 3/4", 1", 11/4", 11/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 — 25mrn 0 10 cc 5—__ U) ________ U) ________ cc W _________ 0 0 120 40 60 80 3.2 6.3 9.5 12.6 15.8 15 :11/4" (32mm)1 1/2'_(40mm)4 103 . 50mm) 0 —J LU 5 35 Q Ci) LU 0 0 50 100 150 200 250 ° FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mf1) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity 4hruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 - 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 - 11/4" 23 35 47 70 1 1/2" 1 32 48 1 63 95 1 52 1 78 1 105 1 167 OUTDOOR INSTALLATION DIRECTION OF FLOW INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall beASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance with- out removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS Model 950XL. Zurn industries, LLC 1 Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Page 2 of 2 Model LP-5/8 5/8" x 3/4" Model 25-5/8, 5/8'x 3/4" Model 35-3/4" Model 55-1 Model 70—i" 2535 GLASGOW DR Recordall® Disc.... - Badger Meter Lead-Free Bronze Alloy, Sizes 5/8 5/8" x 3/4", 3/41i & 1!! NSF/ANSI Standards 61 and 372 Certified DESCRIPTION The Recordall Disc Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a lead-free bronze alloy. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designations: MLP-LL M25-LL, M35-LL, M55-LL, M70-LL) and carry the NSF-61 mark on the housing All components of the lead-free bronze alloy meter (housing, measuring element, seals, and so on) comprise the certified system. Applications: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Operation: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register or encoder face. Operating Performance: The Recordall Disc Series meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates 000 ± 1.5%), and maximum continuous operation flow rates as specifically stated in AWWA Standard C700. Construction: Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber and permanently sealed register or encoder The meter is available in a lead-free bronze alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. Magnetic Drive: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading or AMR/AM[ meter reading options. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. Maintenance: Badger Meter Recordall Disc Series meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like-sized meters and meter models alo minimizes spare parts inventory investment, The built-in strainer has an effective straining area of twice the inlet size. Connections: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Meter Spud and Connection Sizes Model I Size < Designation Length ,, ,, B B Dia. ore Coupling Nut and Spud Thread Tailpiece Pipe Thread LP 5/8" x 7-1/2" 5/8" 3/4(5/8') 1/2" 5/8"x3/4" x 7-1/2" 5/8'3/4" 1(3/4') 3/4" 25 5/8" x 7-1/2" 5/8" 3/4 (5/8") 1/2" 5/8"x3/4" x 7-1/2" 5/8'3/4" 1(3/4") 3/4" 3/4" x 7-1/2" 3/4" 1(3/4") 3/4" 35 3/4" x 9" 3/4" 1' (3/4") 3/4" 3/4"x 1" x 9" 3/4" 1-1/4(1") 1" 55 V. x 10-3/4" 1" 1-1/4(1") 1" 70 1 x 10-3/4" 1" RDM-DS-00464-EN-03 AWWA (October 2015) Product Data Sh eet Recordall® Disc Meters, Lead-Free Bronze Alloy, Sizes 5/8','5/8"x314'1'314"& 1" SPECIFICATIONS Model LP Model 25 Model 35 Model 55 Model 70 (5/8" & 5/8' x 3/4°) (5/8' & 5/8' x 3/4") (3/4') (111) (1) Typical Operating 0.5 ... 20gpm 0.5 ... 25gpm 0.75 ... 35gpm 1 ... 55gpm 1.25 ... 70gpm Range (0.11.4.5 m3/hr) (0.11.5.7 m3/hr) (0.17.7.9 m3/hr) (0.23 ... 1 2.5 m3/hr) (0.28 ... 16 m3/hr) (100%±1.5%) 0.25 gpm 0.25 gpm 0.375 gpm 0.5 gpm 0.75 gpm Low Flow (0.057 m3/hr) (0.057 m3/hr) (0.085 m'/hr) (0.11 m3/hr) (0.17 m3/hr) Mm. 95% Mm. 98.5% Mm. 97% Mm. 95% Mm. 95% Maximum logpm 15 gpm 25 gpm 40 gpm 50 gpm Continuous (2.3 m3/hr) (3.4 m3/hr) (5.7 m3/hr) (9.1 m3/hr) (11.3 m'/hr) Operation 5/8" size: 5/8' size: Pressure Loss 2 psi @ 10 gpm 3.5 psi @ 15 gpm at Maximum (0.14 bar @2.3 m3/hr) (0.24 bar @3.4 m3/hr) 5 psi @25 gpm 3.4 psi @40 gpm 6.5 psi @50 gpm Continuous 5/8" x 3/4" size: 5/8" x 3/4' size: (0.37 bar @5.7 m3/hr) (0.23 bar @9.1 m3/hr) (0.45 bar @ 11.3 m3/hr) Operation 1.5 psi @10 gpm 2.8 psi @ 15 gpm (0.10 bar @2.3 m3/hr) (0.19 bar @3.4 m3/hr) Maximum Operating 80° F (26° C) Temperature Maximum Operating 150 psi (10 bar) Pressure Measuring Nutating disc, positive displacement Element Available in NL bronze and engineered polymer to fit spud thread bore diameter sizes: Meter I 5/8" size: I I I Connections 5/8" or 5/8' (DN 15 mm) 3/4" (DN 20 mm) 1 (DN 25 mm) 1" (DN 25 mm) 3/4" (DN 15 mm) I 5/8" x 3/4" size: I 3/4" (DN 15 mm) MATERIALS Model LP (5/8°&5/8"x3/4') Model 25 1 (5/8"&5/8"x3/4") Model 35 (3/4") Model 55 Model 70 Meter Housing Lead-free bronze alloy Housing Bottom Plates Lead-free bronze alloy, cast iron, engineered polymer Cast iron, lead-free bronze alloy Measuring Chamber Engineered polymer Disc Engineered polymer Trim Stainless steel Strainer Engineered polymer Disc Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Magnet Ceramic Ceramic Ceramic Polymer bonded Ceramic Magnet Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Register Lid and Shroud Engineered polymer, bronze Page 2 RDM-DS-00464-EN-03 AWWA October 2015 25 i'- RecordoiC - 0 . _7 Gallons 3- f ' 25 40% 2 -.7 CubIc Feet .3 iooi:oio: 0 0,09 111, 0925 Recorda0 .:-o,00 .:92 o pa _0,O7 ' m3 0,03 D.Oj1.00iO 'off 0,06 0,04 0,05 "\,\ Product Data Sheet DIMENSIONS Meter Size Model - A Laying Length B Height Reg. C Centerline Base Width Approx. Shipping Weight 5/8"and 5/8"x 3/4" (15 mm) LP 7-1/2" (190 mm) 3.70" (94 mm) 1.26" (32 mm) 3.75(95mm) 3 lb (1.4 kg) 5/8"(15mm) 25 7-1/2(190 mm) 4-15/16" (125 mm) 1-11/16" (42 mm) 4-1/4" (108 mm) 4-1/2 lb (2 kg) 5/8" x 3/4"(15mm) 7-1/2" (190 mm) 4-15/16" (125 mm). 1-11/16" (42 mm) 4-1/4(108 mm) 4-1/2 lb (2 kg) 3/4" (20 mm) 35 7-1/2" (190 mm) 5-1/4" (133 mm) 1-5/8(41 mm) 5" (127'rnm) 5-1/2 lb (2.5 kg) 3/4" (20 mm) 9(229mm) 5-1/4" (133 mm) 1-5/8(41 mm) 5" (127 mm) 5-3/4 lb (2.6 kg) 3/4" x 1" (20 mm) 9(229mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5(127mm) 6 lb (2.7 kg) 1(25mm) 55 10-3/4" (273 mm) 6(152mm) 2-1/32" (52 mm) 6-1/4(159mm) 8-3/4 lb (3.9 kg) 1(25mm) 70 10-3/4" (273 mm) 1 6-1/2" (165 mm) 2-5/16" (59 mm) 1 7-3/4" (197 mm) 1 11-1/2 lb (5.2 kg) REGISTERS / ENCODERS Standard—Sweep-Hand Registration The standard register is a straight-reading, permanently sealed magnetic drive register. Dirt, moisture, tampering and lens fogging problems are eliminated. The register has a six-odometer wheel totalization display, 360° test circle with center sweep hand, and flow finder to detect leaks. Register gearing is made of self-lubricating engineered polymer, which minimizes friction and provides long life.The multi-position register simplifies meter installation and reading. The register capacity is 10,000,000 gallons (1,000,000 ft3, 100,000 m3). A Model 25 register is used in the following example: Model Gallon Cubic Feet I Cubic Meter LP 10 1 0.1 25(5/8") 10 1 0.1/0.01 25(5/8" x 3/4") 10 1 0.1/0.01 35 10 1 0.1 55 10 1 0.1 70 10 L 1 0.1 Optional—Encoders for AMR/AMI Reading Solutions AMR/AMI solutions are available for all Recordall Disc Series meters. All reading options can be removed from the meter without disrupting water service. Badger Meter encoders provide years of reliable, accurate readings for a variety of applications and are also available pre-wired to Badger Meter approved AMR/AMI solutions. See details at www.badgernietev.com. October2015 RDM-DS-00464-EN-03 AWWA Page 3 Recordalle Disc Meters, Lead-Free Bronze Alloy, Sizes 5/8','518"x314','314"& 1" PRESSURE LOSS CHARTS Rate of Flow in Gallons per Minute Model LP 5/8" 25 20 15 vi 10 a- 5 0 Model LP 5/8' x 3/4" 1 10 ion -(I 40 60 80 — ______• — ______. __ __. ____. ______. _____ . — _ _ ____. - _______. — _____.. - ______. _____.. MIM — ______. - ______. 0. — ______. - ______. WIN ME — - Model 255/8" 1 10 100 4 a a 0 40 an an 25 20 15 0 10 0 Page 4 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 25 5/8 x 3/4 Model 35 3/4 1 1 0 100 2 4 6 8 20 40 60 80 25 20 15 vi 10 0 5 0 Model 55 1' 1 10 100 In n on 25 20 0 -J 15 aj 10 5 0 October2015 RDM-DS-00464-EN-03 AWWA Pages Recordall® Disc Meters, Lead-Free Bronze Alloy, Sizes 518','518"x 3/4', 3/4" & 1" PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 701" 1 10 nn an cn 100 25 20 0 -J 15 10 0- 5 0 ACCURACY CHARTS Model LP 5/8' 1 1.0 10 100 Model LP 5/8" x 3/4" 1 1.0 10 100 Page 6 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet ACCURACY CHARTS (CONTINUED) Model 25 5/8 .1 A 1.0 010 100 Model 25 5/8 x 3/40 1 1.0 10 100 .1 C 0 fl .4 C 0 in nfl CA Model 353/4" I I MIN MEW 0 no 00 ___.u.. mmmomm --------------..--------... . ______..u.______...I_______•. ...._____..Ogg..___mommimmommms___•••• • _ MEN ME owns MEMO____.._i______...._____••... OEM momms ------....-----.....------.... mommomm MEEM October2015 RDM-DS-00464-EN-03 AWWA Page 7 0 -: — ---- - Recordall Disc Meters, Lead-Free Bronze Alloy, Sizes 5/8,' 518"x314"' 3/4" & 1" ACCURACY CHARTS (CONTINUED) Model 55 1" 1 1.0 10 100 mom NEE= mmmmmon ------....------....------...I ------...l------....------.... ------....------...I-----..... __... .I—_—___.... 1MR11100 mom IM ZERO El MIM mmommm moons MIMMINEM ------....------...I------.... Model 70 1" 1 1.0 10 DO 100 MEMOS WMNN -----.—..------...U------.—. __.....______...0 • __....__ ME" MEMO ME immmirpmemm -------.l------....------.... -----....------.$..------a..I — (U ~MMMMMMOMOM so • C&10— on ..______...._____....I NEW ME MOM ME Making Water Visible' MAKING WaTER VISIELE arcl PECURDALL are acli';t7red irdernai ks o Badyor Meter, Inc. Other trademarks appearmq this document are the property ol tl sir respective sastites Due tu continuous tpsojrch, pi .sudus'' ii ipruvan ent,s raid enhsiscntnents Sedi' Metar reserves the riyht to 5lir njv product or system spaiilicvtlns without notice. ensept to ha 'etsrit tn csastsndi'cj contractual cl71iq.7tiou cuists, L 2015 8a,Iqcr Mor Inc. All riqht; rou2l'ved. www.badgermeter.com TheAnericas I61rei .a.7'ltlrav, p 5C Mil.,,kc'c 5-Vl 53774v;551 0.00376J3.17 .-iI'l-555-u430 Masico I Catlger Meter de las A,nek. S.A.de c.j. Swim Lair 0s2ri lr72j Erq.Aa.iclina 4 Gskuiu Guadalupe inn cprjrvsc Myra-v OF Mcnirc Europe, Middir, East and Africa I Cadger M,we Eurapa Gr,bH I 1`4mli.viv. SIrS'S I Nui "'w I Europe, Middle Cost ttronih (StOre Cd6erf,Se1,r Europe I roitnr3ni-142 L ic•13,lirau 0-us, thud Quul'sr Lrs-ldi,. Wiu 2,ulCry tQvu Dub,s SiSAL 9?l 4.37 7503 Czech Republic I Sudijer Meter Czech Rapublit sr.o. l:i.,t,l.ov,2l5212, 21 -.51 tSr, 0, l:scl, Eep'.Lle -l27-7-0l42('4t I Stovakla BadijerMete'Slovalda err. I Eirisaslsi 109/i' - t$l 12 Orrir-lava. 51w-aSia I 44212-44u 11331 Asia Padlir Bdt;srMaler IQ Marl-v Pacrtr 5(1 21-06 PLw,is Paude I Laewre3492uS J -i65-n5464b5o China I Cadger Meter I 7-1207 99 Haal,c-v Iliad I Minlvinq 0,121 5isincIlrai I Ch7s 2,1101 e86-21-9763 1412 cc'qucy Dcuec'it iluwbars: I1ISM-O3-c10IM2. 63, Sd, as. cc. :577 ZURN Model 950XL WILKiNS Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 11/4", 11/2" & 2") IAPMO® Listed (vertical 1 1/4"-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern Cali- fornia (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2') NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 3/4", 1", 11/2", 2' Options (Suffixes can be combined) El - with full port QT ball valves (standard) L - less ball valves E U - with union ball valves fl S - with bronze "V type strainer TCU - with test cocks "vertical" up Ej V - with union swivel elbows (3/4" & 1") OSY - with OS & V gate valves E FDC - with fire hydrant connection (2" only) LI FT - with integral male 45° flare SAE test fitting fl PF - with Z-BiteTM push fit connections* (1/2-1 "only) LI PR - with ZPressTM press fit connections* *Fittings ship in box with valve and must be threaded into valve by hand on site. Accessories fl Repair kit (rubber only) E] Thermal expansion tank (Model XT) Ej QT-SET Quick Test Fitting Set Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Dimensions & Weights (do not include pkg.) DIME NSIONS_(a )proximate) WEIGHT MODEL A UNION LESS WITH SIZE A BALL B LESS BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES mm in. mm in. mm in. Imm in. I mmm. mm in. I mm in. I mm 3/4 20 111/4 286 121/2 318 7 178 11/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 112 1/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 12 5.4 11/4* 32 151/2 419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 %6338 W167.3 22 10 11/2 40 171/8435 191/8 486 109/16 268 2 Im 89 41/2 114 41/2 M11425 22 10 2 50 181/4460 20 508 109/16 268 2 89 41/2 114 41/2 28 12.7 *Size 1-1/4" Discontinued Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. D Date: 4/15 Document No. BF-950XL Product No. Model 950XL wwwurncom I Page 1 of 2 Flow Characteristics 0 Rated Flow (established by approval agencies) MODEL 950XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (us) C, Cl) a- U, Cl) 0 —J W cc (I, Cl) Lu cc a- .• 3.2 6.3 9.5 12.6 15.8 15 CX 11/4 (32 m) (40mm) 103 _____ _____ Cl) 10 7 69 0 —J w 35 5 — C') uJ Cc 0 0 50 100 150 200 250 ° FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 Wsec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 52 78 105 167 DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance with- out removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS Model 950XL. Zurn Industries, LLC l Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada ( Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 wwww.zurn.com Page 2 of 2 DOMESTIC WATER - LINE i 10 4 'ffi+ 16 D 12 IIIIIHIII 1•• SEE DETAIL BRASS OR COPPER 10 PRIVATE PUBLIC 8 NOTES: REFER TO DRAWING W-3 FOR SPECIFICATIONS OF 17.5 INSTALLATION OF SERVICE LINE AND APPURTENANCES. DISTRICT;TO SET METER AND BALL VALVE, ALL OTHERS TO BE INSTALLED BY CONTRACTOR. DOMESTIC WATER LINE MATERIAL WILL BE IN 6 CONFORMANCE TO CODE. ALL 2" OR SMALLER COPPER JOINTS SHALL BE PRESS-CONNECT IN CONFORMANCE WITH SPECIFICATIONS. / - SIDEWALK SEE W-3, W-8, 7 ITEM DESCRIPTION SPEC/DWG - COPPER, [TYPE 'K' , SOFT] 15057 2 30; LB. ZINC ANODE LEAD WIRE W-25 3 2" T-7-COPPER TEE (PRESS-CONNLCT) 4 1"90_ COPPER -CONNECT) _BEND _(PRESS 5 NOT USED 6 1" ANGLE METER STOP 7 #37 ARMORCAST METER BOX (OR EQUIVALENT) 8 1" BALL VALVE. WATER METER BY DISTRICT BRASS UNION FIRE APPROVED FIRE _SYSTEM _WATER _LINE _(SIZE _TO_BE_ _BY_ _MARSHAL) 1" DOUBLE CHECK VALVE WITH SHUT OFF VALVES (LEAD FREE) REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT . /h - 02 /1 6 1 02/16 I' DOMESTIC WATER SERVICE CONNECTION DISTfCT ENGINEER DATE WITH FIRE SPRINKLER SYSTEM STANDARD DWG. NO. -