HomeMy WebLinkAbout6200 FLYING L C LN; ; FA100068; PermitUity 01 Uarlsbad Fire Alarm Permit Permit No: FAI 00068 Job Address: 6200 FLYING L C LN Status: ISSUED Permit Type: FALARM Applied 1.1/10/2010 Parcel No: Approved: 11/10/2010 Lot #: 0 Reference No.: Issued: 11/10/2010 PC #: Inspector: Project Title: LEO CARRILLO BARN FIRE ALARM PERMIT (CITY PROJECT) NO CHARGE Applicant: Owner: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Fees ($) Add'I Fees ($) - Total. Balance ($) 0 0 O S 0 .... Icosco 00 •. .. .• •••• 1 Fire Protection Submittals LEO CARRILLO RANCH BARN RESTORATION City Project No. 39611 Contract with: Mark Sauer Construction, Inc. 19712 Temescal Canyon Road Corona, CA 92881-5656 ITuI b ri NOTI Fl ER NOTIIER NOTIiIER I COSCO Fire Protection Fire Protection and Life Safety Specialists FIRE ALARM SYSTEM I MATERIAL SUBMITTAL PARTi#: I DESCRIPTION SECTION 1. Remote Power Supply Remot Power Panel FCPS-24S6 6--AMP Remote Power Supply SECTION 2. INITIATION 1BG-12LX ADDRESSABLE MANUAL PULL STATION with FLASHSCAN (NEW: SP-851 INTELLIGENT PLUG-IN PHOTOELECTRIC SMOKE DETECTOR fl751 INTELLIGENT THERMAL HEAT DETECTOR :(OLP I SMOKE DETECTOR BASE BASE SECTION 3. NOTIFICATION DEVICES :P2w SPECTRALERT HORN/STROBE WALL MOUNT SW SPECTRALERT STROBE WALL MOUNT I SECTION 4. MODULES FCM-1 CONTROL RELAY MODULE SECTION 5. EXISTING DEVICE CUT SHEETS 111FS-640 i INTELLIGENT FIRE ALARM CONTROL PANEL (EXISTING) INTELLIGENT PLUG-IN PHOTOELECTRIC SMOKE DETECTOR fMM-101 MONITOR MODULE jBG-12LX ADDRESSABLE MANUAL PULL STATION (EXISTING) SEE ABOVE SYSTEM SENSOR SYSTEM SENSOR E Rj E E I 02/25/2010 REV.#: 0 PRO.]JECT #: 10CB0261 July 20, 2004 DN-6927• E-30 FCPS-2456 and FCPS-2458 TI- FEE R -mp-an*8-Amp' 24-Volt Remote Power Supplies - Section: Power Supplies GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-24S6/-2458 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA re- quirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notifi- cation appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC4 option module). Alter- nately, the four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FCPS-24S61-24S8 also contains a battery charger capable of charging up to 18 AN batteries. FEATURES UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Cascadable for up to ten power supplies (four for Gentex) with strobe timing maintained. Operates as a "sync follower" or as a "sync generator" (de- fault). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumpered per- manently "ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NAGs. 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load output, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (A77-716B). In stand-alone mode, output power circuits may be config- ured as: resettable (reset line from FACP required), non- resettable, or a mix of two and two. Fully regulated and filtered power output —optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AC trouble report selectable for immediate or 8-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, locking cabinet - 15" (38.1 cm) high x 14.5" (36.83 cm) wide x 2.75" (6.985 cm) deep. Includes integral battery charger capable of charging up to 18 AN batteries. Cabinet capable of housing 7.0 AH batteries. California czi!i;;: A 7315-0028:225 z!j " State Fire LISTED APPROVED S635 I/IEA 299-02-E Battery charger maybe disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. STANDARDS and CODES The FCPS-2456/-2458 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand- alone mode). SPECIFICATIONS Primary (AC) power: FCPS-24S6/-2458: 120 VAC, 60 Hz, 3.2 A maximum. Wire size: minimum #14 AWG (2.0 mm2) with 600 V insulation. Control input circuit: Trigger input voltage: 9 to 32 VDC. Trigger current: 2.0 mA (16-32 V). Per input: 1.0 mA (9- 16 V). Trouble contact rating: 5 amps at 24 VDC. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 -_ For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 INGINHIIIIS & MNUMCTh1l ps NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6927 • 07/20/04 - Page 1 of 3 Auxiliary power output: specific application power 500 mA - maximum.________ - Output circuits: - •-4'24OG4f1tefed-regulated:-- 3.0 amps maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum; for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum charge current: 1.5 amps Maximum battery capacity: 18 AH. APPLICATIONS Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-2456) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-2456) or up to 6.0 amps (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. "Addressable FACPs are capable of locating control and monitor Style Y NAC or modules at distances of up to Door Holder 10,000 feet (3048 meters). Power Output #4 AGENCY LISTINGS AND APPROVALS 4 SYNC FOLLOWER/GENERATOR NOTE PRODUCT LINE INFORMATION FCPS-24S6:6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5"[36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. FCPS-24S8:8.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. ZNAC-4: Class A (Style Z) NAC option module. A77-716B: 12/24 VDC end-of-line relay for monitoring four- wire smoke detector power. BAT.1270: Battery, 12 volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1109). NOTE: All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble Contact Output Style Y NAC Style Y NAC Style Y NAC Output #3 Output #2 Output #1 in some- insta Nat ions1t1s necessary to synchronize the flash - timing of all strobes in the system for ADA compliance. Strobes eeeemHs41his-by-menitor4ng-verys1'iort-timing pulses--on-the-- NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attached to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. See the first page of this data sheet for listing agencies and file numbers. These listings and ap- provals apply to the FCPS-24S6 and the FCPS-2458. In some cases, certain modules or appli- AC • cations may not be listed by cer- Power tain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. INPUT/OUTPUT FUNCTIONS are programmable by SWI DIP switch settings 24 VDC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) FCPS Battery Charger Page 2 of 3 - DN-6927 • 07/20/04 I Sync Input 6827b1ok.Wmf SIMPLIFIED BLOCK DIAGRAM TB2: Power-limited, NAC/Out 1 +. Supervised in NAC Mode NAC/Out 1 with Jumpers J5, JP6, NAC/Out 2 + TBI: Supervised JP7, & JP8 in positions NAC/Out 2- - Earth shown below. NAC/Out 3+ NAC/Out 3- I - AC Neutral NAC/Out 4+ r— AC Hot NAC/Out 4- BOARD LAYOUT Iii '[J2 0 O Non-Power-Limited J2: To Transformer #2 El JI: To Transformer #1 13 is % W F1 lee F1: Battery Fuse 15A,30V 3 c_h III 0 01001 - Battery LEDs (L to R): -AC Power (green) + Battery - Ground Fault (ye//ow) JP4: Supervised, Battery Trouble (yellow) Non-Power-Limited • NAC Trouble (yellow) 18 AH, 24 VDC - Charger Trouble/AC Loss (yellow) Normally Open Normally Closed Common TBS: Trouble Relay Form-C Fail-Safe TB2 ' - 8 7 6 5 4 3 2 (shown energized) it i (D 3 2 1 TB5 JPI: Lj Lj : Lj Ground Fault Detection t_.., ._. ;kh..l J P1 (bUt LU UI3flIW7 J3 - J3: ZNAC-4 ........... Connector JP2 & JP3: Coded/Non-Coded 0 input Selection Auxiliary Output: 10 - -Aux. Common 500 mA Specific- Application Power 9 __________ + Aux. 24 VDC* 8 - -Control Input 7 - + Control Input 2 6 - Out Common 5 - + Out/Trouble Contact 4 --Control Input 1 3 - + Control Input 1 2 - - Sync Input SW1 1 - + Sync Input L PVLLLULI 0 TB4 NOTE: Auxiliary Power Output is power-limited but NOT supervised. SWI: Programming DIP Switches fl CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE-ENGINEERING - BUILDING MATERIALS LISTING PROGRAM—.-----..... -. LISTING-SERVICE ---=- LISTING No. 1,J3150028:0225 Page 1 of I CATEGORY: 7315 -- POWER UNITS LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: . FRANCIS MATEO, Program Coordinator Fire Engineering Division Ordering Information FDU-80: 80 character, backlit, LCD FireAnnL trol switches for remote control of systm fui switch lock. FDU-80C: ULC-Iisted version; see DN-60573 10103: Three-gang electrical box, minimum 22 deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surf cations. Agency Listings And Approv. These listings and approvals apply to the m0 this document. In some cases, certain modulE may not be listed by certain approval agencii be in process. Consult factory for latest listing UL Listed: S635 MEA Listed: 245-00-E FDNY: COA#6038 CSFM: 7120-0028:209 FM Approved NOTE: For ULC-listed version, see DN-6057 88201du8jpQ with con- and key- 188 (5.556 cm) ice-mount appli- S es specified in or applications or listing may FDU-80 :80 Character Liquid Crystal Display NOTIFI by Honeywe D-123 R® General The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. J FE &L\fM 4$CITC1 ft Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal pertoçl the FACP. Displays deiice type identifiers, individual ppint alarm, trou- ble orsupervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188' (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangabla electrical switchbox. Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-E0 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU4.0 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 povides the FACP with up to 32 remote serially co annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ,ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188' (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:B•05/17,310 —Page 1 of 2 44t1 4.i • I NOTIFIER® is registered trademark of Honeyell mt lali nal Inc. 02010 by Honeywell International Inc. All rights resery . Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. FNflhEIlN MriUllr All specifications are subject to change without notice. QUALITY SYSTEMS adeintheU.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. i I ~,i www.notifier.com Page 2 of 2— DN-6820:B • 05/17/2010 SA LISTING SERVICE LISTIllG No. j 7120-0028:0209 . Pge 1 I CATEGORY: 7120—ANNUNCIATORS LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FDU-80 and *FDu80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as annunciators for use separately listed compatible fire alarm control units. Refer manufacturer's installation manual for details. NOTE: )flj CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM *Re 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims.. This listig is not an endorsement or recommendation of the item listed. This listing should not be used to vrfy correct operational requirenients or installation criteria. Refer to listee's data sheet, installation instructions a nd/c r o her suitable : information sources. Date Issued:• July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division .. by Honeywell GENERAL The NOTIFIER NBG-12LX is a state-of-the-art, dual-ac- tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-1 2LX stations per loop on classic protocol systems. Up to 159 NBG-12LX stations per loop on FlashScan® protocol systems. Dual-color LED blinks green to indicate normal on FlashScan® systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from FlashScan® and NOTIFIER® are registered trademarks of Hon- eywell International INC. LEXAN® is a registered trademark of ..t r_._..._._I f'_...__._... June 13, 2005 DN-6726 • H-240 'NBG-12LX IressableManual-Pull Station-- with FlashScan® Section: Intelligent/Addressable Devices Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 091686,286 c®uS California IVI E.A State Fire I _ Marshal 7150-0028:199 67-02-E LISTED S692 U.S. Coast Guard zZ 11 :M (AFP-200) Ii 161.002/23/3 APPROVED 93/60141 (E3) B SMI 02/6007 C1313066760047 The NBG-12LX Addressable Manual Pull Station the bottom of the station. To reset the station, simply un- lock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address set- tings (1 - 159 on FlashScan® systems, 1 - 99 on CLIP systems). product information up-to-date and accurate. We cannot cover all specific applications or I IS09001 I F This document is not intended to be used for installation purposes. We try to keep our I anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 t : a, dl I I ©NOTIFIER' ENSIMIXING A 111111111914131111ING I by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6726 • 06/13/05 - Page 1 of 2 PRODUCT LINE INFORMATION ELECTRICAL SPECIFICATIONS NBG-12LX Dual-action addressable pull station. Normal operating voltageT24 VDC. InfllIdsJ key Jockiogieature__.. _.. .. —.-.Maximum SLC loop voIge: 28.0 VDC. . ................ SB-10 Surface backbox. Maximum SLC loop current: 375 pA. - SB-I/O Indoor/outdoor surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface backbox. If the NBG-12LX is being semi- flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mount- ing with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Back of station without door. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox S13-11 0; or semi-flush mount- ing on a standard single-gang, double-gang, or 40 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Terminal Connections 1 SLC (-) 2 SLC (+) Detail of BREAKAWAY TAB* IJ 14 ¶50 1 ADDRESS 0 13 2 1 , 02 5 LOOP 10 5 7 LL.@i_I 87 o LJ __ LLLfl]I HI HSUq nLED 14wooiju9 i ROTARY TARY DECIMAL SWITCHES "Remove tab to select addresses )Acj 11 above 99 (FlashScan® systems only). ® 0- 0- r SOfl,ItN 0 Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 - DN-6726 • 06/13/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL -BUILDING MATERIALS LISTING PROGRAM--- LISTING-SERVICE-- LISTING No 7150 0028 0199 Page 1 of I CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevchoneyweIl.com DESIGN: Models NBG-12, NBG-125, NBG-I2LR, NBG-12LRA, NBG-I2LAO, NBG-I2LAOB, NBG-1 2-LO, NBG-1 2LOB NBG-12W, NBG-I2LW, NBG-1 2NC, NBG-12WP, NBG-12LWP, NBG-121_,ABG-12LX,.NBG-1•2LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SPNOTBG12LX, NBG-I2LXSP, NBG12LXBL* and NBG12LXP* fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-I2LR.A are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-I2LWP, NBG-I2LAO, NBG-12L0, NBG-121.AOB and NBG-12L0B are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Rev. 04-08-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6935:c • H-202 FSP-8511 FSP-851T, & FSP-851R NOT FI-E-R® 'iñt1iei't PIug.i Photoelectric by Honeywell Intelligent/Addressable Devices General Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously moni- tored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector location for selective main- tenance when chamber contamination reaches an unaccept- able level. The FSP-851 photoelectric detectors unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sens- ing on the FSP-8511. The FSP-851R is a remote test capable detector for use with DNR(W) duct detector housings. FSP-851 series detectors are compatible with all ONYX series Notifier intelligent Fire Alarm Control Panels (FACP). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier that greatly increases the speed of communication between analog Intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of ear- lier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. FlashScan (NFS-320, NFS-640, NFS2-640, NFS-3030, NFS2-3030) and classic CLIP systems (AFP-100, AFP- 200, AFP-300, AFP-400, NFS-640, AM2020/AFP1010, NFS-3030) compatible. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. FSP-851 with B7IOLP base FSP-851T with B7IOLP base Specifications Size: 2.1" (5.3cm) high x 4.1" (10.4cm) diameter installed in B501 base, 6.1" (15.5cm) diameter installed in B710LPbase. Shipping Weight: 5.20z. (147g). Operating Temperature: FSP-851, 0°C to 49°C (32°F to 1200F); FSP-851T, 0°C to 38°C (32°F to 1000F). Low temper- ature signal for FSP-851T at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R installed in a DNR(W), -20°C to 70°C (-4°F to 158°F). ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one com- munication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24VDC ('ON'). BASES AVAILABLE NOTE: 'A" suffix indicates ULC Listed model. dn-6935:c • 3/12/10 -Page 1 of 2 8710LP(A): 6.1" (15.5cm) diameter. FSP-8511:Same as FSP-851 but includes a built-in 135°F 8501 (A): 4.1" (10.4cm) diameter. (57°C) fixed-temperature thermal device. B200SR(A): Intelligent sounder base, configurable for temp-3 FSP-851TA:Same as FSP-851T but with ULC listing. -or. steady sound. -- -•----___________________ - -- FSP-851R: Low-profile intelligent photoelectric sensoi, B224RB(A) Relay Base: Screw Terminals, up to 14AWG remote test capable. For use with DNRW. (2.0mm2); Relay Type, Form-C; Rating, 2.OA @ 30VDC resis- FSP-851 RA: Same as FSP-851 R but with ULC listing. tive, 0.3A © 110VDC inductive, 1.0A © 30VDC inductive; Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1.2" BASES (3.048cm). B71OLP: Standard U.S. low-profile base. B224B1(A) isolator Base: Dimensions, 6.2" (15.748cm) x 1.2" B71OLPBP:Standard U.S. low-profile base, pkg. of 10. (3.048cm) x 1.2" (3.048cm); Maximum, 25 devices between B71OLPA:Standard U.S. low-profile base, ULC listing. isolator bases. Installation FSP-851 plug-in detectors use a separate base to simplify Installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mount base on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: 4.0" (10.16cm) square box. 3.5" (8.89cm) or 4.0" (10.16cm) octagonal box. Single-gang box (except relay or isolator base). With B200SR base, use an appropriate junction box. With B224RB or B224B1 base, use a 3.5" (8.89cm) octago- nal box, or a 4.0" (10.16cm) octagonal or square box. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps' or branches are permitted for style 4 (Class "8") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified In this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1115 ULC Listed: 51115 (FSP-851A, FSP-851TA) MEA Listed: 225-02-E FM Approved CSFM: 7272-0028:206 Maryland State Fire Marshal: Permit #2122 BSMl: C1313066760036 CCCF: Certif. #2004081801000017 (FSP-851T) Certif. #2004081801000016 (FSP-851) Lloyd's Register: 03/60011 Product Line Information NOTE: "A or "CDN" suffix indicates ULC listed model. FSP-851:Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A:Same as FSP-851 but with ULC listing. B501BP:Standard European flangeless base, pkg. of 10. B501A:Standard European flangeless base, ULC listing. B200SR(A): Intelligent sounder base, configurable for temp-3 or steady sound. B224RB(A):intelligent relay base. B224B1(A):lnteiligent isolator base. Isolates SLC from loop shorts. ACCESSORIES F110:Retrofit replacement flange for older style bases. Con- verts older high profile base for use with FlashScan detectors. RA100Z(A):Remote LED annunciator. 3-32VDC. Fits U.S. single-gang electrical box. Supported by B71OLP(A) and B501 (A) bases only. SMK400E:Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400:Recessed mounting kit. For use with B501 (A) base only. SMB600:Surtace mounting kit for use with B71OLP(A). BCK-200B:Black detector covers, box of 10. For use with FSP-851 only. WCK-200B: White detector covers, box of 10. For use with FSP-851 only. M02-04-00:Test magnet. M02-09-00:Test magnet with telescope stick. XR2B:Detector removal tool. Allows installation and/or removal of FlashScan Series detector heads from base in high ceiling installations. T55-127-01O:Detector removal tool withoUt pole. XP-4: Extension pole for XR213. Comes in three 5-ft. sections. NotifieiB and FlashScan® are registered trademarks of Honeywell Interna- tional Inc. Bayblend® is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. .rI=I U We cannot cover all specific applications or anticipate all requirements. EN1119111111111 a MANINT111111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- dn-6935:c • 3/12/10 1I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0206 CATEGORY: 7272 - PHOTOELECTRIC SMOKE DETECTOR Page 1 f 1 LISTE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 • Contact: Vladimir Kireyev (03) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP851R* and FSP-851T photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC ,!. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas witl air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smolderirii fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally Mon effective at detecting fast, flaming fires that consume combustible materials rapidly arid spread quickly. Sources of these fires may include paper burning in a waste containlr or grease fire in the kitchen. *Rev. OP-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering st if has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 4. October 9, 2001 D4-6716°H-210 NOTIFIER Intellige$n'ti"Thermal (Heat) with FlashScaA@ I Section: Intelligent/Addressable De iced GENERAL California The FST-751 Series intelligent thermal detector is used Marshal < CFM~ > State Fire with the intelligent NOTIFIER Fire Alarm Systems to mea- sure thermal levels caused by a fire and report the analog j (J level of the thermal measurement to the control panel. LISTED Approved The use of analog information provides significant ben- S747 MARYLAND efits to the end user, installer, and service personnel in State Fire Marshal VIEA Ways which are not possible with a conventional type sys- Permit 2011 tem. Since this detector is addressable, it helps firefighters 278-99-E to more quickly locate a fire in its early stages. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that CS630 greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communi- cate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek low-profile, stylish.design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-751R), 15°F (8.3°C) per minute. I Factory preset at 135°F (58°C). • 94-5V plastic flammability rating. Addressable by device. • Remote LED output connection to optional RAIOOZ remote I Direct 01 - 159 entry of address (01 - 99 on traditional LED annunciator. systems). • Optional sounder, relay, and isolator bases. Two-wire loop connection. • Optional recessed (RMK400) or surface (SMK400) base Visible LEDs 'blink" every time the unit is addressed. mounting kits. 360°-field viewing angle of the visual alarm indicators (Two APPLICATIONS bicolor LEDs). LEDs blink green in Normal condition and Use thermal detectors for protection of pr perty. turn on steady red in Alarm. Integral communications and built-in device-type iden- For further information call NOTIFIER for Manual 156-407- tification. 00, Applications Manual for System Smoke betectors, which provides detailed information on detector spacing, placement, Remote test feature from the panel. zoning, wiring, and special applications. Built-in functional test switch activated by external mag- net. CONSTRUCTION Walk test with address display (an address of 121 will blink These detectors are constructed of Bayblenc ® in an off-white the detector LED 12-(pause)-1). color. I Low standby current. The FST Series plug-in intelligent thermal deector is de- Listed to UL 521. signed to commercial standards and offers n attractive ap- Built-in tamper-resistant feature. pearance. ° Designed for direct-surface or electrical-box mounting. INSTALLATION Sealed against back pressure. ° Plugs into separate base for ease of installation and main- The FST Series plug-in intelligent thermal letector uses a tenance. separate base to simplify installation, service, and mainte- • Separate base allows interchange of photoelectric, ioniza- nance. tion and thermal sensors. Installation instructions are shipped with ea -,h detector. SEMS screws for wiring of the separate base. Mount base (all base types) on box whici is (38.1 mm) deep. Suitable boxes include: FlashScan® is a registered trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. 1t least 1.5" This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or I anticipate all requirements. All specifications are subject to change without notice. I ISO 901 1 I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 KTT • • N OTI Fl ER 12 Clintonville Road, Northford, Connecticut 06472 I (NINIERINC & MANUMCI1ING DN-6716'10/09101 - Page 1 of 2 1I 4" (101.6 mm) square box. 31-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH or B50IBHT base, use a 4" (101.6 mm) square box. With B224RB orB224Bl base, use a 3-1/2" (88.9 mm) or 41'(101.6 mm) octagonal box, or a 4° (101.6 mm) square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and iso- lator bases. OPERATION Each FST Series uses one of 159 possible addresses (99 on traditional systems) on a control panel SLC loop. It responds to regular polls from the control panel and it reports its type and status, including the analog level of its heat-sensing elements. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm analog level. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel (detector blink is optional). The FST Series offers features and performance that represent the latest in thermal detector technology. SPECIFICATIONS Size: Diameter installed in B7IOLP: 6.1" (154.94 mm); Diameter installed in B501: 4.1" (104.14mm). Height: 1.66" (4216 mm). Weight: 5 oz. (150 gm). Operating temperature: -4°F to 100°F (-20°C to 38°C). Operating humidity range: 10% to 93% relative humidity, no9condensing. Operating voltage/current range: 15 - 28 V (Peak DC), 5 mA current for visible LEDs latched on. Detector standby current: 300 pA @ 24 VDC (one com- munication every 5 seconds with LED blink enabled). For bases B224RB or B224B1: < 700 pA @ 24 VDC (includes detector). Sensor: electronic, dual thermistors. Fixed temperature setpoint: 135°F (57°C). Rate-of-rise option: 15°F (8.3°C) per minute Detector spacing: UL approved for 50 ft. (11.24 m) cen- ter to center. FM approved for 25 x 25 ft. (7.E 2 x7.62 m) spacing. B224RB relay base: Screw terminals: up to 14 AV'G (2.00 mm2). Relay type: Form-C. Ratings: 2 A'@ 3 VC resis- tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VE C inductive. Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. See Note 2 (left column). 8224B1 isolator base: Dimensions: 6.2" (1 25 57.48 mm) diameter x 1.2" (30.48 mm) high. Maximum: devices between isolator bases. See Note 2 (left comn). PRODUCT LINE INFORMATIO Model Description FST-751 Intelligent thermal sensor. FST-751R Intelligent thermal sensor with rat of-rise fea- ture. BASES: B7IOLPBP Standard U.S. style low-profile ba e, package often (10). B501 BP Standard European flangeless bas , pack- age of ten (10). 1350I13H Sounder base, includes 8501 base above. 24 VDC, 85 dBA internal horn. B501 BHT Same as B501BH but with temp ral pattern sounder. B224RB Intelligent relay base. B224B1 Intelligent isolator base. Isolates SI.0 ft'om loop shorts. ACCESSORIES: RA400Z* Remote LED annunciator. 3 - 3 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For us with B501 base only. M02-04-00 Test magnet. WIRING DIAGRAM REMOTE ANNUNCIATOR *Supported by B501 and B7IOLP base only. ARCHITECTURAL & ENGINEERI SPECIFICATIONS Specifications are available on these and al NOTIFIER products. Please contact NOTIFIER. 1111111 t4.itr.J 441L. ii Page 2 of 2 - DN-6716 - 10/09/01 .i1 ui. LISTIIIG No. CATEGORY: LISTEE: DESIGN: : RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE \7270 0028 0196 Page 7270 - HEAT DETECTOR NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com Models FST-751 *851 *851 R, *851 H (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. 1350 F fixed temperature for *Models FST-751, -751R, -851, and -851R *1900 F fixed temperature for Model FST-851 H In accordance with listee's printed installation instructions, applicable codes and ordinance and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL label. Listed as heat detectors for use with Models B501 or B71OLP base (CSFM Listing No. 7300-0028:173) and separately listed compatable fire alarm control units. Refer to listee's Installation Instructions Manual for details. NOTE *Rev. I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineerir'tg staff the test results and/or other data but does not make an independent verification of any claims. This listi endorsement or recommendation of the item listed. This listing should not be used to verify c rrec requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division reviewed is not an operational r suitable SYSTEM Selectable Output Notification Devices SpectrAlert Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug in designs, instant feedback messages to ensure correct installation of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: 12 or 24 volts At 24 volts, 15,15/75, 30, 75, 95, 110, 115, 135, 150,177 or 185 candela by way of rear-mounted slide switch and front viewing window Horn tones and volume by way of rotary switch The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features Plug-in design Same mounting plate for wall- and ceiling-mount units Shorting spring on mounting plate for continuity check befDre installation Captive mounting screw Tamper resistance capability Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75,95,110,115,135,150,177,185 Automatic selection of 12 or 24 volt operation at 15 an 15/5 candela Outdoor wall and ceiling products Outdoor products rated from —40° to 151°F Minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for tone selection 3 horn volume settings Electrically compatible with existing SpectrAlert products Aciencv Listinas SIGNALING MEA 25- 16531 56 6sd.,ce 1170305) X,';25-1652307 ,o.tJoo, mobes) USTED APPROVED approved 71 25-1653:108 hc,v3uob,$) 7125. 1655:159 'hcrs 54011 3023572 M5A452-05-E SpectrAlert Advance Specificationr -- General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17a-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing afl Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit _______ listed to UL 4.64 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 H and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 0 x 06 x 2k-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature .32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate . I flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18AWG Ceiling mount dimensions (including lens) 6.8'diameter x 2.5 high (173 mm diameter x 64mm high) Wall mount dimensions (including lens) 5.61 x 4.7W x 251) (142 mm Lx 119 mm W x 64mm D) Horn dimensions 5.61 x 4.7W x 1.31) (142 mm Lx 119 mm Wx33 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. P S, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd. AO5O39SOO2 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS)LIJ T Current pDraw znm1li 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 _DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 17 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 -Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Horn Tones and Sound Output Data Setting Repetition Rate dB level Switch 8-17.5 Volts 16-33 Volts 1 Temporal horn High Position Sound Pattern dB DC FWR DC FWR 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7 Externally coded High 6 Non-temporal Low 75 75 81 81 8 Externally coded Medium 7 Coded High 82 82 88 88 9. Externally coded Low 8* Coded Medium 78 78 85 85 9. Coded Low 75 75 81 81 Settings 7,8, and 9 are not available on 2-wire horn/strobe. A050395-002 -SpectrAlert Advance Dimensioni I!'I ii I I -_ a. SpectrAlert Advance Ordering Information Model Description yr Wail Horn/Strobes P2R" 2-wire Horn/Strobe, Standardcd6, Red P2RH 2-wire Horn/Strobe, Hiqh cd, Red P2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK" 2-wire Horn/Strobe, High cd, Red, Outdoor P2W' 2-wire Horn/Strobe, Standard cd, White Ceiling Horn/Strobes (contd.) PC2W" 2-wire Horn/Strobe, Standard cd, White PO\/M"t 2-wire Horn/Strobe, High cd, White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P2WH" 2-wire Horn/Strobe, High cd, White PC413HK 4-wire Horn/Strobe, High cd, Red, Outdoor P4R' 4-wire Horn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd, White P4RH* 4-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W" 4-wire Horn/Strobe, Standard cd, White SCRH Strobe, High cd, Red P4WH 4-wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR*t Strobe, Standard cd, Red SCW Strobe, Standard cd, White SRH*t Strobe, High cd, Red SCWH"' Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW" Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd, White HW Horn, White Ceiling Horn/Strobes Accessories PC2R' 2-wire Horn/Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red PC2RH" 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White PORK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red PC2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor BBSCW-2 Back Box Skirt, Ceiling, White Notes: "Add -Pto model number for plain housing (no"FlREmarking on cover), e.g., P2R-P t Add -SPto model number for FUEGO marking on cover, e.g., P2R-SP * High cd refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cdrefers to strobes that include 15,15/75,30,75, 95, 1 10, and 115 candela settings. "\ STEM 3825 Ohio Avenue. St. Charles IL 60174 e000nstodrargerlronrno r more ,emsensorcomro, 02066 Sys Sensor. SE,tISOR° Phone: 800-SENSOR2• Fax: 630-377-6495 AOS0395002 .7/06#1659 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL F1R-ENGINEERING--.BU1L-DING-MATERIALS LISTING PROGRAM--- LISTING No. t7125-16530186 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave,, St. Charles, IL 60174 Contact: Irish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhartcsystemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW,SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT.and SCWH followed'15y the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDCIF\NR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 85cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division LISTE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave,, St. Charles, IL 60174 Contact: Irish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and.CHSW Chime/Strobes. Models 132R, ",132W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, 134W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..WBBW (Wall), SA-WBBC (Ceiling) and *sA..\r.BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceili mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. or wall CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED "Rev. 1 H . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering still \ the test results and/or other data but does not make an independent verification of any claims. This I eniorsement or recommendation of the item listed. This listing should not be used to verify cor requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division -08 bh reviewed is not an operational r suitable FCM-1 (A)&FRM.1 (A) Series Control and Relay Modules General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.) Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FRM-1(A) may be programmed to operate dry contacts for applications such as door holders or Air Handling Unit shut- down, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding. releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan® releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). dn-6724:b2 NOTIFIER® byHoneywe1t FCM1(A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) dn-6724:b2 • 6/17/10 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5 (114.3 mm) high x 4 (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4 (101.6 mm) square x 2.125' (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5 (114.3 mm) high x 4 (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4 (101.6 mm) square x 2.125 (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. IJL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:202, 7300-0028:219 MEA: 14-00-E FDNY: COA #6038, #6026 Contact Ratings for FRM.1 (A) Current Maximum Load Voltage Description Application 3A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (LIR=5ms) 1A 30 VDC Inductive Coded (LIR=2ms) .3A 125 VAC Inductive (PF=0.35) Non-Coded Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: 'A° suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document /56-1169. FRM-1(A) Installation document /56-3502. Notifier SLC Wiring Manual, document 51253. External supply voltage -(betweenTerminaIs.Tio and Til): Maximum (NAG): Regulated 24 VDC; Maximum - ......................_(Speakers):. 70.7 V.RMS,OW Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. NotifierO and FlashScan® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell international Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 'TI K_-174 b dl 1130 We cannot cover all specific applications or anticipate all requirements. ENUNtlNG s MANFACTUIUNS All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- dn-6724:b2 • 6/17/10 Made in the U.S. A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE-ENGINEERlNG-.BUILDING MATERIALS LISTING PROGRAM ------- G--S-ERV1,G-E----- _01M -------------- LISTING No. 7300-002&6219 Page 1 of 1 CATEGORY: 7300 - MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules and FCM-1, FRM-1 control modules*. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 08-18-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division NFS-640 Intelligent Addressable Fire Alarm System NOTI Fl by HoneyweI A-30 General The NFS-640 intelligent Fire Alarm Control Panel is part of the pNYX® Series of Fire Alarm Controls from NOTIFIER. As a staid-aloIie small-to-large system, or as a large network, he ONYX® Series of products meets virtually every application requirement. Designed with modularity and for ease of system planning, the NFS-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise applica- tion. Simply add additional peripheral equipment to suit the application. Features '• One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors (any mix of ion, photo, thermal, or multi- sensor) and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay) per SLC. 318 devices per loop! 636 per FACP or network node. Standard 80-character display, 640-character large display, or display-less (a node on a network). Network option - 103 nodes supported (NFS-640, NCA Net- work Annunciator, or NCS Network Control Station) using wire or fiber-optic connections. 6.0 amp switch mode power supply with four Class A/B built- in Notification Appliance Circuits (NAC). Selectable System Sensor strote synchronization. I Built-in Alarm, Trouble, and Supervisory relays. Up to 64 output circuits per FACP or network node; circuits configurable online. VeriFire® Tools offline program option. Sort Maintenance Reports by compensation value (dirty detector), peak alarm value, or address. Autoprogramming and Walk Test reports. Optional universal 636-point DACT. 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). , History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with tally. Autoprogramming and Walk Test reports. Positive Alarm Sequence (PAS) Presignal. Silence inhibit and Auto Silence timer options. March time / temporal / California two-stage coding I strobe synchronization. Field-programmable on panel or on PC, with VeriFire® Tools program check, compare, simulate. Full QWERTY keypad. Charger for up to 90 hours of standby power. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. NFS-640 shown in CAB-B4 ,vi NCA 640-character disDIv. Powerful Boolean logic equations. NCA 640-CHARACTER DISPLAY FEA TU ES: Backlit, 640-character display. Supports SCS Series smoke control systerr in both HVAC or FSCS modes (not UL-Listed for FSCSp. Printer and CRT EIA-232 ports. EIA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security relays! FLASHSCAN® INTELLIGENT FEATURE: Poll 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Pa tent 5539,389). Manual sensitivity adjustment - nine levels Pre-alarm intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion —0.5 to 2.50/6/foot obscuration. - Photo —0.5 to 2.35%/foot obscuration. - Laser (VIEW®) —0.02 to 2.00/o/foot obscu atio i. -Acclimate PIusTM - 0.5 to 4.00/./foot obs cura ion. - HARSHTM - 0.5 to 2.350/6/foot obscuratio Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the CPU-640 microprocessor fails, FlashScan® dete tors revert to degraded operation and can activate the C U-640 NAC cir- cuits and alarm relay. Each of the four buil -in panel circuits includes a Disable/Enable switch for this feawre.I DN-6856:A. 12/tl/061_Pase 1 of 9 Multi-detector algorithm involves nearby detectors in alarm • Requires auxiliary 24 VDC from system r remote power decision (U.S. Patent 5,627515). supply. Automatic detector sensitivity testing. RELEASING FEATURES: Maintenance alert (two levels). Ten independent hazards. Self-optimizing pre-alarm. • Sophisticated cross-zone (three options). .1 VIEW®; (VERY INTELLIGENT EARLY WARNING) • Delay timer and Discharge timers (adjustabl)). SMOKE DETECTION TECHNOLOGY: • Abort (four options). Revolutionary spot laser design. • Low-pressure CO2 listed. Advanced intelligent sensing algorithms differentiate between VOICE AND TELEPHONE FEATURS: smok6 and non-smoke signals (U.S. Patent 5831,524). .1 • Addressable operation pinpoints the fire location. • Solid state message generation. No moving parts to fail or filters to change. • Hard-wired voice control module options. Early warning performance comparable to the best aspiration • Firefighter telephone option. systems at a fraction of the lifetime cost. • 30- to 120-watt high-efficiency amplifiers (A Series). Backup tone generator and amplifier option. ACCL IMA TE FL US TM LOW-PROFILE INTELLIGENT MUL TI-SENSOR: • Multichannel voice transponder (XPlQ). • Detector automatically adjusts sensitivity levels without oper- HIGH-EFFICIENCY OFFLINE SWITCHING ator intervention or programming. Sensitivity increases with 3.0 AMP POWER SUPPLY (6.0 A IN ALARM): heat. • 120 or 220/240 VAC. Microprocessor-based technology; combination photo and • Displays battery current/voltage on panel (with display). thermal technology. FlashScan® or classic mode compatible with NF5640. FlashScan® Low-temperature warning signal at 40°F ± 5°F (4.44°C ± Exclusive World-Leading Det 'cor Pro-2.77°C). tocol HARSHTM HOSTILE-AREA SMOKE HEAD: At the heart of the NFS-640 is a set of detection devices and Provides early warning of smoke detection in environment device protocol - FlashScan® (U.S. Patent 5 539 389). Flash- where traditional smoke detectors are not practical. Scan® is an all-digital protocol that gives supei ior i recision and The detector's filters remove particulates down to 30 microns high noise immunity. in size. In addition to providing quick identification o anactive input device, this protocol can also activate many o tput.devices in a Intake fan draws air into photo chamber, while airborne parti- fraction of the time required by competitive prc tocols. This high des and water mist are removed. SLC Intelligent Loop I Up to 32 Remote - - -DE-;,jw -J. * j iDispliys.i(i. (FX R bill R7 FAPT-851 Acclimate Plus°" - FSL-751 FlashScanO VIEWS FF X126/10 I/O FSP-851 photo ' FSH.751 FtashScan® HARSH NBG-12LX FMM-1 FIlM-i XPS Series, XPiQ L_J etc. Modules 0 SDRF- I SLC Intelligent Loop 2 IDC Relay Contact 5817C5 751 LCD-80 FDU-8O DEVICES I FSP-851 FSI851 _,t,, t .•••. EIA -485 Photo ion Thermal ------- NBG-12LX FMM.i FCM-1 XP5-M XPS-C XPIQ ¶1 : L EIA -4 85 2048 annunciator/control point lit j IDC NAC L 1 2dilaL~_ _ 31 ISE on NCA ____ 44• . [j_j 'II OR 4 _ with no display ACM-SR ACM/AEM-24AT LD? 32 4 -. .. 4 * Up to 64 fully Relay Control LED Annunciator Cus om raphics 4 programmable 4 I Optional 636 point UDACT Oua phone 10 lines to output circuits 4 I 4 I Central 4 I EIA-232 Terminal Statfon Sample optiops System I NFS-640 4 shown in CAB-C4 with (DM-2 and voice alarm system PRN Printer CRT-2 Terminal Page 2019— ON-6856:A • 12/01/06 iii screen 4$4 speed also allows the NFS-640 to have the largest device per loop capacity in the industry —318 points - yet every input and output device is sampled in less than two seconds. The micro- processor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. Intelligent Sensing Intelligent sensing is a set of software algorithms that provide he NFS-640 ¶ith industry-leading smoke detection capability. These c6plex algorithms require many calculations on each reading of each detector, and are made possible by the very- high-speed microcomputer used by the NFS-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Iaintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self- restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for ffSelf-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of this intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre- alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature of the NFS-640. It is a special software routine that allows the NFS-640 to "learn" what devices are physically connected and automatically load them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-2) The NFS-640, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-640 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS-640 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Windows® based and provides technologically advanced capabilities to aid the installer. The installer may create the entire am for the NFS-640 in the comfort of the office, test it, st backup file, then bring it to the site and download from oo into the panel. I ENTER PROG)R STATPASSWORD. THE ENTER 14ESCAPTO ABORT- . OzCLR 1= AUTO 2POINT PASS WORD =MESSNE Above: Keypad program editing. Below: Autoprogram funct on. AUTOPROSRAM, P1ASEWAfl' 080DfiTS15MODSL93DETS PANEL OUTPUTS24 BELLS 04 S !T VeriFire ToolsSystem DN-6856:A• 12141/06 - Page 3 of 9 TOP, LEFT to RIGHT: J8 Zone Code Input; TB7 DC Power (24 VDC power-limited, both resettable and non-resettabl ava lable,); TB8 Alarm Relay; TB9 Trouble Relay; TWO Supervisory Relay; TBII Security Relay; SWI, SW5 Relay Switches; JPI3 Genera I Br Earth Fault Jumper; TBI2 EIA-485 Terminal Mode (supervised); TBI3 ElA-485 ACS Mode (supervised); TBI4 EIA-23 Pri tar; r615 ElA-232 PC Terminal; JI NUP (network/service connection: power-limited, supervised); TBI6 SLC #1 Connections (d tectrs, modules; supervised); D55 Main SLC Ground Fault LED; JP7 Charger Disable Jumper; JPI2 200MA Jumper; JP6 Ea h F4ult Jumper '1 (SLC#1) J8 187 168 189 TWO 1611 TB12 1513 T814 TB15 TBI6 0 0 T6 UNACLEDs i v1c SW5 D55 JP6 (TB5,4,3&so) l !I 1 (1 JPl3 behind display T85r : L JP7behincl display 184 1 h •th 183 POwn FIRE PRCI.ARM SECURItY SUPERVISORY SYWTRM SIGNALS POINT CPU ALARM TROIRILS SILENCER SISAILES KDM-2 Display Disable/Enable Switches for soon ama. svmt. we NAC Circuit J7 • scoou.moPIsy SILENCE OCLCflCC SCENT to,, .072 Degraded Mode : behind display 1 082. 82 —ED mo J3 151 D-=D Q D54; Control Switches SW2,\ _/ J4, J5, J6 behind display \____________ JIO ill \_/ I; SW3, SW4; and System Status Indicator LEDs (for "No-Keyboard Operation behind display LEFT SIDE, TOP to BOTTOM: TB6 NAC #1, TB5 NAC #2, TB4 NAC #3, TB3 NAC #4 (all NAC circuits power-limited nd supervised, and each NAC TB has an NAC LED to the right of it); J7 Accessory Power; Disable/Enable Switches for Degraded M de; tB2 AC Power Connection; TBI Battery Connection (overcurrent protected). BOTTOM, LEFT to RIGHT: D54 AC On LED; stem Status Indicator LEDs for "No-Keyboard Operation"; System Switches SW2 (Acknowledge), SW3 (Silence), SW4 (Reset) for " No-Keyboard u Operation"; J4 KDM-2 Connector; J5, J6 Panel Circuits (ONYX® Panel Output Modules, supervised); D72 General Board Ground Fault LED; JIO Security Tamper Switch; Jil Auxiliary Trouble Input; D82 AC Power LED; J3 LEM-320 Connector (SLC Loo) #2). Network Diagram APT NCS APT II Block Diagram 24V NOTI• FIRE- NETTM NFS-640 ACS PAN NF5640 Sample Node Configurations PAN IIJI OOO° NFN Dual Flber.Optic Link LCD-80 Other Interfaces ACS OPTIONAL Style 7 Connection PXPI NCA speakers speakers phones phones Page 4o19— ON-6856:A • 12/01/06 in display. On iy options are or more CPU- ftion device is i QWERTY pro- 1 blank modules ires top row of a haracter display ,odes to display e NCA or NCS pork information. cters. On single -y Display for the 1.0E.1 On network net,vork display em. On network ri NM retwork ACr node or in include the DP- s the'ABS-2D. In vo BMP-1 blank data sheet ON- 13A amp (6.0 A i. Inludes CPU; instllation, pro- )er system or as VAC, 1.5 amp, Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-640's flexible system design. Rows: The first row of equipment in the cabinet mounts in chassis CHS-M2. Mount the second, third, or fourth rows of equipment in chassis CHS-4MB (see NFS-640 Installation Man- ual regarding panel output modules) or CHS-4L (for voice com- ponents, see Vpice Alarm System Manual). Wiring: henI designing the cabinet layout, consider separa- ion of power-limited and non-power-limited wiring as discussed in the NFS-640 Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items available for different combinations and configurations of components. It is critical that all mounting holes of the NFS-640 are secured with a screw or. standoff to ensure continuity of Earth Ground. Layers: The CHS-M2 accepts four layers of equipment, includ- ing the control panel. The CPU-640 fills three positions (left to right) in the first-installed layer (the back of the chassis); its inte- gral power supply occupies (the left) two positions in the next two layers; the optional display occupies (the left) two positions at the front, flush with the door. Panel output modules can be mounted in several layers with standoffs or an L-bracket as required. Some equipment, such as the NCA, may be door- mounted directly in front of the control panel. The NCA mounts onto the DP-DlSP or ADP-413. The NCA can be used as a pri- mary display for the NFS-640 by directly connecting their net- work ports (required in Canadian stand-alone applications). Expansion: Installing an LEM-320 Loop Expander Module adds a secondi SLC loop to the control panel. The LEM-320 is mounted onto the CPU-640, occupying the middle-right, second (back) slot on the chassis. If networking two or more control panels, each unit requires a NCM-W (wire) or NCM-F (fiber) Network pontrol Module. The NCM-W/-F can be installed in any panel output module position (see manual); the default position is at the back of the chassis next to the control panel. Option boards can be mounted in front of the LEM-320 or NCM mod- ules; for ease of access, complete installation of those devices before mounting another layer. CHS-M2 CPU-640 KDM-2 Controls and Program Keypad: QWERTY type (keyboard I you). 8 LED indicators: Power; Fire Alarm; Pre- arm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled. Membrane Switch Controls: Acknowledge/S roll Display; Signal Silence; Drill; System Reset; Lamp Test LCD Display: 80 characters (2 x 40) wth Ic g-Iif LED back- light. Configuration Guidelines Stand-alone and network systems require a single-CPU systems (one CPU-6401-640E), di the KDM-2 or the NCA. On network systems (t 640/-640Es), at least one NCA or NCS annw required. Other options listed as follows: KDM-2: 80-character backlit LCD display wit gramming and control keypad. Order two BMP and DP-DlSP mounting plate separately. ReqL cabinet. Required for each stand-alone 80-i system. The KDM-2 may mount in network "local" node information as long as at least network display is on the system to display net NCA: Network Control Annunciator, 640 char CPU-640/-640E systems, the NCA is the Prime panel and connects directly to the CPU-640/-6 systems (two or more CPU-640/-640Es), one (either NCA or NCS) is required for every sys systems, the NCA connects (and requires) communications module. Mounts in a row of two annunciator positions. Mounting options DISP, ADP-4B, or in an annunciator box, such CAB-4 top-row applications, a DP-DISP and I modules are required for mounting. See NC 6858. CPU-640: Central processing unit with integr in alarm) power supply for an NFS-640 Ayster one Signaling Line Circuit expandable M two; gramming and operating manuals. Orde/ one necessary (up to 103 network nodes) on a neti CPU-640E: Same as CPU-640 but requires 2 (3.0 A in alarm). Integral power supply 11 Wil H 0 ti KDM-2 shown with dress plate, or NCA at front, flush with door. Panel output module mounted on L-bracket in front of control panel Mounting location for LEM-320 Typical mounting location for NCM or TM-4 11 Available mounting slots for panel output modules DN-6856:A• 12/1/06,— Page 5 of 9 : CHS-M2: Mounting chassis for CPU-640. One required for VTCC-i B: Voice/Telephone Control Center. 3rovdes all that each CPU-640/-640E. the VCC-1 provides plus two-way Fire Fighters TelE phone (FFT- DP-DISP: Dress panel for top row in cabinet with CPU-640/- 7) capability. 640E installed. TCC-1B: Telephone Control Center. Provides ajstand-alone BMP-1: Blank module for unused module positions, two-way Fire Fighters telephone (FF17S). System Modules Includes cables, dress panel and instructions. I RM-1/RM-1SA: Remote microphone assemblies; mount on The NFS-640 includes the ability to communicate with up to ADP-4 (RM-1) dress panel or CAB-RM/-RMR RM.1 SA) stand- eight conventional modules each with up to eight circuits. Any alone cabinets. See DN-6 728. Lcrophone). ix of notification, relay, speaker, or telephone may be used. AMG-E: Audio Message Generator witho t Choose any combination of up to eight output modules: lCM/ Order in addition to VCC-1 or CC-1 if:two-c anel system is ICE, CRM/CRE, DCM-4 or VCMNCE. Panel modules mount on required. either: the two far-right positions of the DP-DISP (next to the pn- FFT-7/FFT.7S: Fire Fighters Telephone con rol with master mary display); or on any of the four positions on the CHS-4N handset. chassis (CHS-4MN kit required). FTM-1: Firephone Control Module connects a remote firefighter NOTES: 1) These modules/expanders are NOT to be used for telephone to a centralized telephone console. Reports status to releasing applications. 2) For additional information on these panel panel. Wiring to jacks and handsets is supervised. output modules and expanders, see data sheet DN-6859. AA-30: Audio Amplifier, 30 watts. Switch-mod power. Includes CHS-4MB: Expansion Chassis. Mounts up to four modules, amplifier and audio input supervision, backup input, and auto- Includes CHS-4N, MP-1 B (Module Dress Panel), and Expander matic switchover, power supply, cables. See AA Series data Ribbon Cable. sheet, ON-3224. ICM-4RK: Notification Appliance Circuit Module, provides four AA-120/AA-100: Audio Amplifier provides up t:) 120 wafts of 25 Style V (Class B) or Style Z (Class A) alarm Notification Appli- Vrms audio power for the NFS-640. The amplifier! contains an ance Circuits. Maximum signaling current is 3.0 amps per circuit or 6.0 amps per module, subject to limitations integral chassis for mounting to a CAB-B4, -C , or -D4 backbox power supply auxiliary power harness, ELRs and slide-in labels). (consumes one row). Switch-mode power. Include audio input I (includes and amplified output supervision, backup inpt t, arrd automatic Includes ON/OFF controls and ON/OFF LEDs. switchover to backup tone. Order the AA-100 for 747 Vrrs sys- ICE-4: Notification Appliance Circuit Expander, expands ICM-4 tems and 100 watts of power. See AA Series data sheet, ON- to provide a total of eight Style V or Style Z alarm Notification 3224. i rl staIlation in Appliance Circuits. Circuit rafings are same as lCM-4. VROM-(n): Factory-programmed message for NOTE: Maximum of one per ICM-4RK. May also be used to add AMG-1. Provides up to 24 seconds of evacua ion message on four Notification Appliance Circuits to VCM-4. nonvolatile memory chip. Choose one of many standard mes- CRM-4RK: Control Relay Module, four Form-C relay contacts, sages available. Up to two of these messages in one AMG. Includes VROM, instructions foi may be installed installation and rated at 5.0 A, 120 VAC or 28 VDC (resistive) per circuit. operation, and written text of message. See V Includes manual ON/OFF controls and LEDs. DN-3576. IOM data sheet ' .CRE-4: Control Relay Expander, expands CRM-4 to provide a VRAM-1: Field-programmed memory to be installed in AMG 1 total of eight Form-C relay contacts. Note: maximum of one per Provides up to 24 seconds of field-pro ramr abl evacuation CRM-4RK. May also be connected to add four relays to ICM-4, irCM-2, TCM-4, or VCM-4. message on nonvolatile memory chip. Mssag 3 is programmed VCM-4RK: Voice Control Module four Style V provides (25 and from microphone or cassette tape. Up to two of memory chips may be installed in AMG one these nonvolatile Includes VRAM 70 Vrms) and Style Z (25 Vrms only) speaker circuits, eight and instructions for installation and operation. manual select switches and indicators, slide-in labels, and plug- in terminal blocks. Move jumper to convert to telephone circuits APS-6R: Auxiliary Power Supply (expander). F rovides up to 6.0 with remote ring signal and local call-in flash. May be expanded amperes of regulated power for compatible Notification ance circuits. Includes battery input and transfE appli- r relay, and over- to eight circuits with VCE-4, ICE-4, or CRE4. current protection. Mounts on one of four positions on a CHS-4L VCE-4: Voice Control Expander adds four circuits to VCM-4. or CHS-4 chassis. See APS-6R data sheet, 0 -5952. i Note: VCM-4/ VCE-4 combination must be eight speaker or ACPS-2406: 6.0 amp addressable charger power supply. See eight phone circuits. ACPS-2406 data sheet, DN-6834. DCM-4RK: Dual Channel Module pro-vides four Class B (Style FCPS-24: The FCPS-24 is a remote six-amp 'four-amp contin- Y, 25 & 70 Vrms) or Class A (Style Z, 25 Vrms only) speaker cir- uous) repeater/power supply. See FCPS-24 lata sheet, ON- • cults plus four channel NB select relays. Not expandable. 5132. , . OTHER OPTION MODULES FCPS-24S6/-24S8: Remote six-amp and eigh amp power sup- ARM-4: Auxiliary Relay Module, four Form-C relays controlled plies with battery charger. See FCPS-24S61-24S6 datàsheet, by a relay module (CRM-4 or CRE-4). N.O. contacts rated 20 DN-6927. amps; N.C. contacts rated 10 amps at 125 VAC and 30 VDC. UZC-256: Programmable Universal Zone Cod r p ovides posi- NOTE: Maximum of one for each CRM-4 or CRE-4 . tive non-interfering successive zone coding. Microprocessor- VCC-1B: Voice Control Center. Provides a variety of user- controlled, field-programmable from IBM®- (requires optional programming kit). See UZ( omatible PCs -256 data sheet, selectable tones on a single channel. Up to two different tones DN-3404. or messages may be selected on a single channel. Also pro- Mides optional digital voice message capability and on-site pro- LCD-8OILCD-8OTMJFDU-80: 80-character, backlit LCD dis- 'grammable voice messages. Includes Audio Message Generator (AtlG-1) microphone, cables, dress panels, and play. Mounts up to 6,000 ft. (1828.8 m) from i NFS-640. See LCD-80/-BOTM (DN-3198) and nel. Up to 32 per FDU-80 (ON- instructions. 6820) data sheets. I ACS: Annunciator Control ACM I Modules -1 AT, AEM-16AT j ACM-32A, and AEM-32A. See data sheets, I -0 24 and ON- 6862.. Page 6 of 9- DN-6856:A • 12/01/06 AFM: Annunciator Fixed Modules AFM-16A, AFM-I6AT, and AFM-32A. See AFM data sheet, DN-0056. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32. See LDM data sheet, DN-0551. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ACM-8R data sheet, ON-3558. $CS: Smoke control station; eight (expandable to 16) circuits. See SCS data sheet, DN-4818. RPT485 Repats ElA-485 over twisted pair or converts to giber-optic medium. See RPT data sheet, DN-4 73 7. XP5: The XP5-M and XP5-C provide FlashScan® transponder points. See XP5 data sheet, DN-6625. XP: The XP Series Transponder provides conventional monitor and control points (CLIP mode only). See XP Series data sheet, DN-0 759. XPIQ: The XPIQ quad intelligent voice transponder for distrib- uted multichannel voice evacuation systems, an integrated udio amplification and distribution subsystem controlled by FACP. Capable of playing up to four simultaneous messages. Accepts up to four 25-watt amplifiers. See XPIQ data sheet, ON- 6823. CHS-4: Chassis for mounting up to four APS-6Rs. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. DP-113: Blank Dress panel. Provides dead-front panel for unused tiers or to cover AA-30, AA-120, or one AMG-E and one AA-30. CAB4 Series: The CAB4 Series cabinets are fabricated from 16-gauge steel with unique full-front LEXAN®, reverse-silk- screened for durability. The cabinet assembly consists of two basic parts: a 8ackbox (SBB-_4), and a Locking Door (DR-_4) hat may hinge1 right or left. Cabinets are available in four sizes, CA" through "D' with one to four tiers. A trim ring option is avail- ble for semi-flush mounting. See CAB-4 Series data sheet, ON- 6857. CAB-M Series' Marine cabinets required for Lloyd's Register or U.S. Coast Guard listed use. See ON-5063. COMPATIBLE DEVICES, EIA -232 PORTS PRN-5: 80-column printer. See DN-6 769. PRN-6: 80-column printer. See DN-6956. V54095/52: Printer, 40-column, 24 V. Mounted in external backbox. Order from Keltron, Inc. See DN-3260. CRT-2: Video display terminal. See DN-3 756. COMPATIBLE DEVICES, EIA -485 PORTS ACS Series: Remote serial annunciator/control systems. See DN-0524. FDU-80: Remote LCD display, 80 characters, with LEDs. See ON-6820. LCD-80: Remote LCD display, 80 characters. See DN-3198. LCD-80TM: Remote LCD display, 80 characters, terminal mode. See DN-3198. LDM Series: Remote custom graphic driver modules. See ON- 055 1. ACM-8R: Remote relay module. 8 Form-C relays. See ON-3558. RPT-485 Series: Repeater, isolator and/or fiber-optic modem. See ON-4 73 7. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UZC-256: Zone Coder. Up to 256 programmable codes. See pN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receivi 200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflect below. See ON-6985. BEAMLRK: Long-range accessory kit, FSB-21 BEAMMRK: Multi-mount kit, FSB-200(S) belo BEAMSMK: Surface-mount kit, FSB-20c(S) bi FSB-200: Intelligent beam smoke detect, Sc FSB-2005: Intelligent beam smoke detector w tvity test. See ON-6895. FSI-851: Low-profile FlashScan® ion izatioi replace FSI-751. See ON-6934. FSi-751: Low-profile FlashScan® ionization d 6714. FSP-851: Low-profile FlashScan® photoelec raplace FSP-751. See ON-6935. FSP-751: Low-profile FlashScan® photoelect DN-6714. FSP-8511: Low-profile FlashScan® photoelec 135°F (57°C) thermal, will replace FSP-751T. FSP-751T: Low-profile FlashScan® photoelec 135°F (57°C) thermal. See DN-6714. FST-851: FlashScan® thermal detector 13 replace FST-751. See DN-6936. FST-751: FlashScan® thermal detector 135°F 6716. FST-851 R: FlashScan® thermal detector 1 rate-of-rise, will replace FST-751 R. See DN-69 FST-751 R: FlashScan® thermal detector I rate-of-rise. See ON-6716. FST-851H: FlashScan® 190°F (88°C) high-t mal detector. See DN-6936. FSD-751P: FlashScan® photo duct detctor DN-6821. FSD-751PL: Low-flow FlashScan® photo dL housing, will replace FSD-751P. See DN-6955. FSD-751RP: FlashScan® photo duct detectc Iousing. FSD-751 RPL: Low-flow FlashScan® photo d relay and housing, will replace FSD-751 RR Se FAPT-851: FlashScan® Acclimate PlusTM low sor detector, will replace FAPT-751. See DN-& FAPT-751: Acclimate PlusTM low-profile mult See ON-6833. FSH-751: FlashScan® HARSHTM Hostile An See ON-6875. FSL-751: FlashScan® VIEW® laser photo det LPX-751. See ON-6886. LPX-751: Low-profile VIEW® laser photo df 5306. 6224RB: Low-profile relay base. E224B1: Isolator base for low-profile detectors E71OLP: Low-profile base. Standard U.S. styli E501: European-style, 4(10.16cm) base. E501BH: Sounder base, includes B501 base tone. E501 BHT: Sounder base, includes B501 base three tone. I FMM-1: FlashScan® monitor module. Se DA FDM-1: FlashScan® dual monitor module. Se DN-6856:A • 1 of FSB- FSB-200(S) below. integral sensi- detector, will ctor. See ON- detector, will detector. See detector with DN-6935. detector with (57C), will 57 C). See DN- IF with IF (57°C) with nperature ther- h ousing. See I etector with with relay and t detector with ON-6955. rofile multi-sen- 7. ensor detector. Smoke Head. tor, will replace fctbr. See DN- bove. Constant Lbol/e. Temporal 46720. /06- Page 7 of 9 NCM-F: Network Communications Module, NCM per network node (CPU-640 or NCA). Se NCS5-W-ONYX: Network Control Station, graphics PC with mouse, 17' color flat-scre Order as necessary for network systems. Eac one of 103 network addresses. See ON-686 W), ONYX® ON-6869. NCS5-F-ONYX: Network Control Station, graphics PC with mouse, 17' color fla1-scre Order as necessary for network systems Eac one of 103 network addresses. See ON-6868 ( ONYX® DN-6869. VerlFlre-TCD: VeriFire® Tools CD-ROM. C ming software for the NFS-640, NCA, and XPI panel connection cable. Programming PC req connection. See ON-6871. ACM-24A1: ONYX® Series ACS annunciator of annunciation with Alarm or Active LED, switch per circuit. Active/Alarm LEDs can be powered-up switch selection) by point to be r low; the Trouble LED is always yellow. See DN AEM-24AT: Same LED and switch capabilitiE expands the ACM-24AT to 48, 72, or 96 points. ACM-48A: ONYX® Series ACS annunciator - of annunciation with Alarm or Active LED p Alarm LEDs can be programmed (by powered tion) in groups of 24 to be red, green, or yeIlo 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-4 ACM-48A to 96 points. See ON-6862. BAT Series: Batteries. NFS-640 utilizes two AH batteries. See ON-6933. PS Series: Batteries. NFS-640 utilizes two 12 batteries. See ON-1109. NFS-LBB: Battery Box (required for batteries BR: Same as above but red. O1r one 6861. UL-Listed D monitor. consumes vious NCS- UL-Listed ) monitor. consumes is NCS-F), hs program- cludes local a serial port up to 96 points uble LED, and ogrammed (by green, or yel- s as ACM-24A1, See DN-6862. up1to 96 points r circuit. Active/ up switchl selec- i. Epandable to A, exprds the 2 v,lt, 12 to 55 dolt. 12 to 55 AH ver 25 AH). 11 FZM-1: FlashScan® two-wire detector monitor module. See DN-6 720. FMM-101: FlashScan® miniature monitor module. See ON- 6720. I FCM-1: lashScan® NAC control module. See:DN-6 724. rRM1: Flashcan® relay module. See DN-6724. FSM-101: FlahScan® pull station monitor module. NBG-12LX: Manual fire alarm station, addressable. See ON-6726. ISO-X: Isolator module. See ON-2243. XP Series: Transponder. See DN-0 759. XP5-M: FlashScan® transponder, five monitor points. See ON-6625. XP5-C: FlashScan® transponder, five control points or Form-C relays. See DN-6625. XP6-C: FlashScan® six-circuit supervised control module. See DN-6924. bP6-MA: FlashScan® six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan® six-relay (Form-C) control module. See ON-6926. XP10-M: FlashScan® ten-input monitor module. See DN-6923. XPIQ: Intelligent quad transponder. See DN-6823. OTHER OPTIONS DPI-232: Direct Panel Interface, specialized modem for extend- ing serial data links to remotely located FACPs and/or peripher- als. See ON-6870. LEM-320: Loop Expander Module. Expands each 640 to two Signaling Line circuits. See ON-6881. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (single-address-style) or in CHS-M2 position. See DN- 6860. NCM-W:' Network Communications Module, Wire. Order one 'JCM per network node (CPU-640 or NCA). See ON-6861. Page 8 of 9 — DN-6856:A • 12/01/06 SYSTEM SPECIFICATIONS System Capacity .s Intelligent Signaling Line Circuits ............1 expandable to 2 Intelligent dtectors .........................................159 per loop Addre1ssabl6 monitor/control modules ......... ..... 159 per loop Programmable internal hardware and output circuits (4 standard)......................................................................68 o Programmable software zones.........................................99 Special programming zones.............................................14 LCD annunciators per CPU-640/-640E and NCA (observe power)................................................................32 ACS annunciators per CPU-640/-640E .........................................................32 address x 64 points p ACS annunciators per NCA ..................32 address x 64 or 96 points NOTE: The NCA supports up to 96 annunciator address points per ACM-24/48. Specifications Primary input power, CPU-640 board: 120 VAC, 50/60 Hz, 3.0 amps. CPU-640E board: 220/240 VAC, 50/60 Hz, 1.5 Amps. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 Amps of available power. This is shared by all internal modules. Standard notification circuits (4): 2.5 A each. p Four-wire detector power: 1.25 A. k Non-rsettale regulated power outputs: 1.25 A each. Battery chager range: 12 AH —55 AH. Use separate cabi- net for batteries over 25 AH. Optional high-capacity (25 - 120 AH) battery charger: CHG-120 (see CHG-120 data sheet, DN-6040). Float rate: 27.6 V. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0- 49°C/32 - 120°F and at a relative humidity 93%:t 2% RH . noncondensing) at 32°C ± 2°C (90°F t 30F). However, the jseful life of the systems standby batteries and the electronic I components may be adversely affected by ex reme tempera- ture ranges and humidity. Therefore, it is reci mmnded that this system and its peripherals be installed in in environment with a normal room temperature of 15 —27°C 30 -t 800F. Agency Listings and App'óv Is The listings and approvals below apply to th bas1c NFS-640 control panel. In some cases, certain modules not be listed by certain approval agencies, or listing may bE in process. Con- suit factory for latest listing status. UL: S635 ULC:CS118 FM APPROVED Exceptions - CPU-640 PRN-5, Propri- etary service CSFM: 7165-0028:214, 7170-0028:216 MEA:317-01-E City of Chicago City of Denver Lloyd's Register: 02/60007 U.S. Coast Guard: 161.002/42/1 China Classification Society (CCS #1-0500001 (NFS-640E) CCCF: Certif. #2003081801600815 Standards The NFS-640 complies with the following U Standards and NFPA 72 Fire Alarm Systems requirements: - UL 864 (Fire) - UL 1076 (Burglary) - LOCAL (Automatic, Manual, Waerflo Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Wa (requires 4XTMF). - REMOTE STATION (Automatic, Manua Waterflow) (requires 4XTMF). - PROPRIETARY (Automatic, Manual and Not applicable for FM. - EMERGENCY VOICE/ALARM. Acclimate Plus, HARSHTM, NIS, Notifier Integrated ystnisTMnd NO- TI-FIRE-NET are all trademarks; and FlashScan®, IN ION I, NOTIFIER®, ONYX®, UniNet®, VeriFire®, and VIEW® are all regitere trademarks of Honeywell International Inc. I ©2006 by Honeywell International Inc. All rights reserved. unauthorized use of this document is strictly prohibited. ISO 9001 ENSINUNI & MANilM1UR1NC QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 9o1 9— D-6856:A. 12/01/06 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:0214 Page 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com Model NFS-640, NFS-640E fire alarm control units. Local, auxiliary, remote station (PPU) proprietary (PPU), central station (PPU), automatic, manual, waterfiow and sprinkler supervisory services. Refer to listees data sheet for detailed product description and operational considerations. System components: CPU-640, 640E CPU Board NCA Network Communication Annunicator NCM-W/F Network Control Module LEM-320 Loop Expander Module KDM-2 Keyboard Display Module TM-4 Transmitter Module CAB-4 Series Enclosure TR-A4, -134, -C4, -D4 Trim Ring DP-DISP Display Dress Panel DP-1 B Blank Panel BMP-1 Blank Module XPDP, DPDW-1B, DPSW-1B, VP-2B Dress Panels CHS-4MB, -M2, 4L, -4N Chassis NFS-LBB, BB-25, BB-17 Battery Box BP-4 Battery Panel STS-1 Security Tamper Swith UDACT Universal DACT UZC-256 Universal Zone Coder ACM-8R, -16AT, -32A, 24A, 48A Annunciator Control Module AEM-1 6AT, AEM-32A, 24AT,-48A Annunciator Expander Modules AFM-16A, AFM-16AT, AFM-32A Annunciator Fixed Modules AKS-1 B Annunciator Key Switch RPT-W, RPT-485W, RPT485WF Repeater Wire RPT-F Repeater Fiber *SCS8 Smoke Control Station *scE..8 Smoke Control Expander *SCS..8L Smoke Control Lamp Driver Station *SCE8L Smoke Control Expander Lamp LCD-80 Liquid Crystal Display LCD-80TM AnnunciatorTerminal Module LCD LDM-32, -E32, -R32 Lamp Driver Module RA400, -400Z, FDU-80 Remote Annunciators Rev. 01 009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering st the test results and/or other data but does not make an independent verification of any claims. This endorsement or recommendation of the item listed. This listing should not be used to verify c requirements or installation criteria. Refer to listee's data sheet, installation instructions andk information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division s r.viewed g iè1not an operational er suitable MARKING: APPROVAL: RATING: INSTALLATION: Listing No. 7165-0I2 Page 2o3 FFT-7, -7S Fire Fighter's Telephone FHS Fireman's Handset FPJ Fireman's Phone Jack RPJ-1 Remote Fireman's Phone Jack VCM-4RK Voice Control Module VCE-4 Voice Control Expander ARM-4 Auxiliary Relay Module AMG-1, -E Audio Message Generator AA-30, -100, -120 Amplifiers *Rev. 06-24-2009 fm Listing No. 7165-0028:214 Page 2 of 2 ABF-1 B-i DB,-2B,-2DB,-4B,-4DB Annunciator Enclosures ABS-1TB, -213 Annunciator Surface Box APS-6R/APS-6RE Auxiliary Power supply ACPS-2406 Addressable Power Supply & Battery Charger CHG-120 Battery Charger FCPS-24 Field Charger/Power Supply DCM-4RK Dual Channel Module CCM-1 Communication Module CRM-4RK Control Relay Module CRE-4 Control Relay Expander lCM-4RK Indicating Control Expander ICE-4 Indicating Circuit Expander ISO-X Isolator Module XP5-M, XP5-C Transponder XPIQ Transponder Quad Intelligent Audio XPC-8 Transponder Control Module XPM-8, XPM-8L Transponder Monitor Modules XPP-1 Transponder Processor XPR-8 Transponder Relay Module PRN-5 Printer V54095 Keltron Remote Printer CRT-2 Display Terminal ACT-11, -2 Audio Coupling Transformer RM-1, RM-1SA Remote Microphone NBG-12LX Addressable Manual Pull Station NBG-12LRA Agent Release Abort Station FZM-1 Interface Module REL-2.2K Releasing Supervision Kit In accordance with listee's printed installation instructions, applicable codes and ordir and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. *Also suitable for high-rise applications. *Rev. C This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering st !\ the test results and/or other data but does not make an independent verification of any claims. This endorsement or recommendation of the item listed. This listing should not be used to verify o requirements or installation criteria. Refer to listee's data sheet, installation instructions andk information sources. 14 fm is reviewed is not an opdrational er suitable Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: 1 FRANCIS MATEO, Program Coordinator Fire Engineering Division :J• Listing No. 7165-0021 '1 Page 3o 3 These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, *9th Edition Standard NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 2. Combined with 7170-0028:214 *Rev. 0-24-2009 fm tit This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff as reviewed 0'• the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify c rrec operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/ 0 her suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 1' Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Oil December 15, 2000 Dt'1-6714• H-200 NOTIFIER ' OTIFlER® FSI-751 andcFSP-751/751T Low-Profile Intelligent Plug-in FIRE S YS TEAl S rSmoke Detectors with FlasiScan® Section: Intelligent/Addressable De ices GENERAL California tate Fire The NOTIFIER FSP-751 (photo) and FSI-751 (ion) are ana- larshal log, addressable, low-profile (height measures only 1.66"! 272-0028:206 42.164 mm) smoke detectors designed for the entire line of FSF-751/-751 T) intelligent systems from NOTIFIER. The FSP-7511 photo LISTED CS308 271-0028:201 model includes a built-in thermal (heat) detection device. If FSI-751) either condition (smoke or heat) is detected, the device will S1115 alarm. MARYLAND The addressability of the FSP-751 and FSI-751 enables the State Fire Marshal MEA c 277-99-E control panel to provide firefighters with a pinpoint descrip- 2020 (Fsl-751) ion of where the fire is located. The FSP-751 and FSI-751 Approved (FSP-751/2013 (FsP-751/-7517) I 751T only) are also analog devices. The control panel is capable of not only knowing the detector's location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of its location. Analog devices continually send obscuration values to the con- trol panel. These values may be gathered so as to allow the OWN N control panel to determine if a detector has accumulated an \ / excessive amount of dirt or dust. A "maintenance" required indication allows the installer to clean the smoke detector be Ww - fore an unwanted false alarm occurs. The FSl-751 Intelligent Ionization Sensor incorporates a \,,, unique single-source chamber design to respond quickly and dependably to a broad range of fires. -_--.--._. '-. 8714ph01.Jpg The FSP-751 Intelligent Photoelectric Sensor's unique Opti- FSP-751T with B7IOLP base , cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion sources. — -'----' FlashScan® (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices and certain NOTIFIER systems. Intelligent de- -- vices commuhicate in a grouped fashion. If one of the de- vices within the group has new information, the panel's CPU FSP-751 with RMK400 recessed friounting kit stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of Visible bicolor LEDs blink green eveçy tim the detector is earlier designs. addressed, and illuminate steady red on lanii. FlashScan® is a registered trademark of NOTIFIER. I Walk test with address display (an addres of 121 will blink FEATURES the detector LED: 12-(pause)-1) (Flash 3can@ systems only). Sleek, low-profile design (height only 1.66"!42.164 mm). • Built-in functional test switch activated b i external mag- Common base for both photo and ion detectors, net. Addressable-analog communication. • Optional relay, isolator, or sounder bases Stable communication technique with noise immunity. • Listed to UL 268. Low standby current. 16 Rotary 01 to 159 address switches (01 to 99 on traditional SPECIFICATIONS systems). Size: 1.66" (42.16 mm) high x4.1" (104.14 mm) diameter. Optional remote, single-gang LED accessory (RA400Z). Shipping weight: 3.6 oz. (104 g). Dual LED design provides 360° viewing angle. Operating temperature: 0°C to 49°C (32° to 120°F). This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or I ISO 90( 1 I anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 • = .3 NOTIFIER 12 Clintonville Road, Northford, Connecticut 06472 INGINMINC & MRNIIFAC1UINC I DN-6714• 12/1/00 - Page 1 of 4 UL listed velocity range: ION: 0- 1500 fpm (0 - 7.62 ml PRODUCT LINE INFORMATION sec). PHOTO: 0 - 4000 fpm (0 - 20.32 mlsec). Model Description Relative humidity: 10% - 93% noncondensing. FSI-751 Low-profile intelligent ionization si ' ELECTRICAL SPECIFICATIONS: be mounted to one of the bases list Voltage range: 15 - 32 volts DC peak. FSP-751 Low-profile intelligent photoelectr Standby current - ION: 200 pA @ 24 VDC (without corn- Must be mounted to one of the bas munication); 300 pA 24 VDC (one communication every low. 5 seconds with LED enabled). FSP-751T Same as FSP-751 but includes a b Standby current - PHOTO: 250 pA @ 24 VDC (without (57"C) fixed-temperature thermal d communication); 360 pA @ 24 VDC (one communication BASES: every 5 seconds with LED enabled). B7IOLPBP Standard U.S. low-profile base, pk LED current (max.): 6.5 mA @ 24 VDC ('ON"). B501 BP Standard European flarigeless base, Air velocity ratings: FSP-751 & FSP-751T: to 4,000 ftfmin. B501 BH Sounder base, includes B501 base (1219.2 rn/mm.). FSI-751: to 1,500ft./min. (457.2 mlmin.). B501 BHT Same as B501 BH, but includes tempi) BASES AVAILABLE: B224RB Intelligent relay base. B7IOLP: 6.1" (154.94 mm) diameter. B224B1 Intelligent isolator base. IsoIats S B501: 4.1" (104.14 mm) diameter. shorts. B50IBH or B5OIBHT: Sounder base assembly. Includes ACCESSORIES: * B501 base. SDG-773 Smoke Detector Guard. This guar B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 cally compatible with both FSI-751 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC detectors. It is UL-compatibility Ii resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC in- FSP-751 (file UL S5515). It is N0 ductive. Dimensions: 6.2" (157.48 mm)x 1.2" (30.48 mm). ibility listed with the FSI-751. B524B1 Isolator Base: Dimensions: 6.2" (157.48 mm)x FIIO Retrofit replacement flange for B, 1.2" (30.48 mm). Maximum: 25 devices between isolator Converts BX-501 base for use witl bases, detectors. Duct applications: FSP-751 and FSP-751T are Listed for RA400Z* Remote LED annunciator. 3 - 3 use in air ducts. See Duct Application Guide A05-1004 for U.S. single-gang electrical box. details on pendant-mount applications. NOTE: These prod- SMK400 Surface mounting kit provides for ucts are NOT Listed for use inside a duct smoke detector face wiring conduit. For use with . housing. only. INSTALLATION RMK400 Recessed mounting kit. For use wit The FSP-751 and FSl-751 plug-in detectors use a separate only. base to simplify installation, service, and maintenance. A SMB600 Surface mounting kit for use with I special tool allows maintenance personnel to plug in and re- M02-04-01 Test magnet. move detectors without using a ladder. M02-09-00 Test magnet with telescope stick. Mount base on a box which is at least 1.5" (38.1 mm) deep. XR-2 Detector removal tool. Allows inst Suitable mounting base boxes include: or removal of FlashScan Series de 4" (101.6 mm) square box. from base in high ceiling installatio 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. XP-4 Extension pole for XR-2. Comes Single-gang box (except relay or isolator base). foot sections. With B56IBH base, use a 4" (101.6 mm) square box. "Supported by B7IOLP _____ 4 . With B224RB or B22481 base, use a 3-1/2" (88.9 mm) and B501 bases only. Ali octagonal box, or a 4" (101.6 mm) octagonal or square box. lation and/ tor heads three five- nsor. Must d below. nic sensor. s listed be- ilt-in 135"F vic. I. O 10. kg. of 10. thove. ral sounder. C fr m loop is r,echani- rid FSP-751 ed with the IJL-Compat- -501 base. FlashScan VDC. Fits ntry of sur- B501 base B01 base MO;LP. SMOKE GUARD Cover: 16 gauge perforated steel (3/16' [4.7625 mm] dia. perforations on 1/4" [6.35 mm] staggered centers). 51% open. SDG-773 is 3" (76.2 mm) deep by 7(177.8 mm) wide. OPTIONAL Frame: 3/4' x 3/4" (19.05 x 19.05 mm) angle, 14 gauge solid SDG773 Smoke Guard (1.905 cm) (1.905 cm) All guards are supplied with the following: Guards fasten to mounting frame with No. 10/24 x 3/8" 3/4_] 7' (17.78 cm) (9.525 mm) long Allen-head screws (10/24 spanner-head screws and tool option at extra cost). Ceiling Standard finish: "Cool Tan" baked enamel. 3.: MODEL NO. or wag (7.62 cm): SDG-773 MOUNTING DIAGRAM SDG-773 Smoke Guard 4762sdgm.wf Page 2of4 - DN-6714•12115100 El DETECTORS, EXPLODED VIEW SENSOR LER COVER REMOVAL TABS SENSOR MMM1MIJMIM11MMIM SCREEN SENSING CHAMBER flIJUIIllILiITLT1 COVER SENSING HUMtH IHH CHAMBER SENSOR S6REEN I IfXSI SENSING CHAMBER AI Ell Lin ii--- FSI-751 Ion LED 6714exp1wmf FSP-751 and FSP-751T Photo TEST MAGNET POSITIONING PAINTED SURFACE"\ 12" STATUS LEC LED AGNET/ ' MAGNET TEST TEST INDICATORS MARKER PAINTED TEST SURFACE MAGNETI 6714ma9l.wrf FSP-751 and FSP-751T Photo PAINTED' SURFACE "MAGNET TEST MA £JEJJ PAINTED SURFACE FSI-751 Ion DN-6714' 1211 4-. Page 3of4 I WIRING DIAGRAMS Listed Compatible CONTROL PANEL REMOTE ANNUNCIATOR 1 I- 22 2 1 _________________ ------------------------------------------------ OPTIONAL RETURN LOOP --- + i• FSP-751 and FSP-751T Photo REMOTE ANNUNCIATOR A! CAUTION + I - DO NOT LOOP wire under terminals I or 2. Break wire run to provide supervision of conne tions. 3 i W2 3 W, 2 3 Vjl~ STYLE T OPTIONAL WIRING -----/---------- AAk FSI-751 Ion Page 4of4 - DN-6714• 12/15/00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE !:-7272-0028:0206 LISTIG No. Page 1 CATEGORY: 7272 - PHOTOELECTRIC SMOKE DETECTOR LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP-851 R* and FSP-8511 photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, I FAPT-851, FSP-851, FSP-851 R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 04000 fpm. Model HPX-751 is suitable for opn areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas witi air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or grease fire in the kitchen. Rev. 0 -0720O9 fm This listing is based upon technical data submitted by the applicant. CSFM Fire EngineeriTg the testresults and/or other data but does not make an independent verification of any claims.I 1 endorsement or recommendation of the item listed. This listing should not be used to verify requirements or installation criteria. Refer to listee's data sheet, installation instructions at information sources. reviewed is not an operational r suitable Date Issued: July .01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING 4 BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. '7271-0028:0201 Page 1 lof 1 CATEGORY: 7271 - IONIZATION SMOKE DETECTOR LISTEE: NOTIFIEROne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Model FSl-751 and *FSI 851 ionization smoke detector. Refer to listees data sheet for detailed product description and operational considerations. RATING: I. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as an ionization smoke detectors for use with listees listed Models BX501, B61OLP, B612LP, B614LP, B616LP or B7IOLP bases (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. Model FSI-751 is suitable for open area protection at air velocities up to 500 fpm. *Model FSI-851 is suitable for open area protection at air velocities up to 1200 fpm. NOTE Là 4 1 This listing is based upon technical data submitted by the applicant. CSFM Fire Enginee the test results and/or other data but aoes not make an independent verification of any clairr 4 js endorsement or recommendation of the item listed. This listing should not be used to v requirements or installation criteria. Refer to listees data sheet, installation instructions information sources. *Rev. 11 24-2002 JW rirg st if l)as reviewed s. This listiig is not an 'en c rreth operational and/or other suitable Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA rEQ Program Coordinator Fire Engineering Division .4 FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End (provided) terminates the Style B circuit. required for supervision of the Style D circuit. FM114-1(A) OPERATION Each FMM-1(A) uses one of the available m on an SLC loop. It responds to regular polls panel and reports its type and the status (op of its Initiating Device Circuit (IDC). A fashir that the module is in communication With t The LED latches steady on alarm (subject tions on the loop). F114114-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 41 Humidity range: 10% to 93% noncondensinç Dimensions: 4.5" (11.43 cm) high x 4° (iC 1.25" (3.175 cm) deep. Mounts to a 4° (10: 2.125" (5.398 cm) deep box. ie Resistor resistor is addresses the control indicates ol panel. nt limita- 1 com- .16cm) wide x 6 C) square x FMM.1 (A), FMM-1 01(A), FZM-1 (A) & FDM.1 (A) Monitor Modules with FlashScan® NOTUFI by Honeywe 0:C 'H-220 General Four different monitor modules are available for Notifiers intel- ligent control panels for a variety of applications. Monitor mod- ules supervise, a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3° (3.302 cm) H x 2.75° (6.985 cm) W x 0.5° (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A)to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs.. FMM.1 (A) Monitor Module L Built-in type Identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. I LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class DN-6720:C • 10I06/010; Page 1 014 Dimensions: 1.30 (3.302 cm) high x 2.75' 0.65° (1.651 cm) deep. Wire length: 60 (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke dete Supervises IDC wiring and connection c source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for eat Direct-dial entry of address: 01 - 15 on F 01 —99 on CLIP loops. LED flashes during normal operation; this ble option. LED latches steady to indicate alarm or control panel. The FZM-1(A) Interface Module is intended gent, addressable systems, where the indi each module is selected using built-in rota module allows intelligent panels to interface wire conventional smoke detectors. It transmi mal, open, or alarm) of one full zone of conv back to the control panel. All two-wire deter bred must be UL compatible with the modul can be used to replace MMX-2(A) module tems. FZM-1(A) APPLICATIONS Use the FZM.1(A) to monitor a zone of two-w tors. The monitored circuit may be wired as (Class B) or Style D (Class A) Initiating Devic ohm End-of-Line Resistor (provided) terminat Style B or D (class B or A) circuit (maximurT tance is 25 ohms). Install ELR across termi Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the availalle m on an SLC loop. It responds to regular polls panel and reports its type and the statiJs (op of its Initiating Device Circuit (IDC). A flashir that the module is in communication with tt The LED latches steady on alarm (subject tons on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 comr LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Termin DC voltage: 24 volts power limited. Ripple v maximum. Current: 90 mA per module maxirr Temperature range: 32°F to 120°F (0°C to 4 Humidity range: 10% to 93% noncondensinç Dimensions: 45° (11.43 cm) high x 40 (11 1.25 (3.175 cm) deep. Mounts to a 4' (10. 2.125° (5.398 cm) deep box. cm) Mde x external power of viring. shcan loops, a programma- ommand from Dr use in intelli- Jual address of switches. This nd monitor two- the status (nor- tional detectors rs being moni- The FZM-1(A) in existing sys- e shoke detec- n NFPA Style B Cicuit. A 3.9 K sthe end of the IDC loop resis- ials'8 and 9 for addresses the control LED indicates control panel. current Iimita- and 1 t3 and T4): e: 0.1 Vrms 16cm) wide x 5 cr) square x FMM-1 01 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial 4ntry of address: 01 - 159 on FashScan loops; 01 —99 on cLIP loops. 1415 1 ADDRESS 0 1 'i 1 21 _ " 3 3 11 4 LOOP 4 10 _____ TENS ONES U o 1w cII(.) -.1 J LU .-J 0 cx The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Page 2 of 4— DN-6720:C • 10/06/2010 FDMI (A) Dual Monitor Module The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire Initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED NOTE: The FDM-1(A) provides two Style B (Class B) IOC circuits ONLY. Style 0 (Class A) IDC circuits are NOT supported in any 'applicatiqn. FDM-1('A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses 26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAU1iON: ,void duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4' (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform o applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals - 161.002/23/3 (A FP-200.- FMM-1I-101, F - 161.002/42/1 (NFS-640: FMM- 11-10 1) Lloyd's Register: —03/60011/El (FMM-1/-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM-1) —02/60007 (NFS-640: FOM- 1) FDNY: COA #6038 (NFS2-640, NFS-3 COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01 (A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detector FDM-1(A): Monitor module, dual, two indepei Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer the SLC Wiring Manual, PN51253. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC:S635 FM Approvd , CSFM: 7306-0028:0219 MEA:457-99-E U.S. Coast Guard: ON-6720:C. 10/06/01 0:— Page 30? 4 r. 14110 1 FireWatchhTI is authorized use FlashScan® and NOTIFIER® are registered Ira a trademark of Honeywell international Inc. 02010 by Honeywell International Inc. All rights of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IIHIN MNFP&1URIN All specifications are subject to change without notice. QUALITY SYISTIMS i For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:C • 10/06/2010 I, the U.S. A. LISTING No. CATEGORY LISTEE: DESIGN: 4iI RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0028:0219 Pagel flj 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules and FCM-1, FIRMA control modules*. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational• considerations. 16-33 VDC Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listees name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. Rev. 08-18-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering St If has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an %j endorsement or recommendation of the item listed. This listing should not be used to verify Cl Tect operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/c other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 11 Feature ,f ..j • Absorbent Glass Mat (AGM) technol gy for superior 4 performance - - ' I • Valve regulated, spill proof construction allows safe 4400 OF ~-VJPA lo Power/volume ratio yielding unrivaled energy density ,J • Rugged impact resistant ABS cse E nd cover (UL94-HB) ' • Approved for transport by air. D.0.T. I.A.T.A., F.A.A. and C.A.B. certified rt . • U.L. recognized under file number F\ H20845 Terminals. Performance Specifications CE h' Nominal Voltage ........................................................................ 12 volts (6 cells) I 1-3.4-1 Nominal Capacity F2 - Quick fl disconnect 16.35 20-hr. (450mA to 10.50 volts) .............................9.00 - Mate with AMP. INC 10-hr. (810mA to 10.50 volts) ..............................8.1O1Ai-t FASTON "250' series 7.95 —I 5-hr. (1.44A to 10.20 volts) ...............................7.20 AH I I 0.8 1-hr. (5.4A to 9.00 volts) .....................................5.4oAH:1 15-mm. (14.4A to 9.00 volts) ...................................3.60 AH Physical Dimensions: In (m Approximate weight ..................................................6.00 lbs. (2.72 kg) I Energy Density (20-hr. rate) ..............................1.9 2 w-h/in3 (116.94 W-h/1) DID . I Specific Energy (20-hr. rate) .............................18.1 0W-h/lb (39.68 W-h/kg) . iI F -i I I f I., I I w Internal Resistance (approx.) .........................i..........13 milliohms I, I I Max Discharge Current (7 Mm.) ...............................27.0 amperes Max Short-Duration Discharge Current (10 Sec.) ..90.0 amperes Shelf Life (% of nominal capacity at68°F(20°C)) — 1 Month ...................................................................... . HI H 3 Months .................................................................. .................................. 91% 6 Months ...................................................................83% U I , . Operating Temperature Range L Charge .. ............................. .............................. -4°F(-20°C)t0122°F(50°C) Discharge ....................................................... -40°F (-40°C) to 140°F (60°C), ; FL.95 (151) W256 (65) H3 70 (94- HI 386(98) Case ABS Plastic Ii Tolerances are +1- 0.04 in. (1- 1mm) and +/-0.08 In. (+1-2mm) for Power-Sonic Chargers................................................PS-128O0A, 12800AtC' height dimensions. All data Subject to change without notice. : ••• )j I4 t Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material saf ty data sheets (MSDS), ISO certification, etc.. Discharge Depth 100% Discharge Depth 50°/ Discharge Depth 30% 1. Discharge Current 0.2C 1- - 2. Charge Current: 0.IC -I-.- 3. Ambient Temperature 20°C I Vo tage 1.7V1CelI) to 2 °C (68°F to 77°F) 200 400 600 800 1000 1200 Number of Cycles 120 100 80 CL 60 0 C .9 40 C 20 0 0 Discharge Characteritics Discharge Time 80 Life Characteristics inSta I I Ambient Tempe Float Charging Volta 2.25 - 2.30 V/Cell e 100 'a 0. ce 60 C-, 40 C o 20 0 0 Use 20°C (68°F) ..-i-- •-i.uuIuI 7 0 1 2 3 4 Years Life Characteristics in C cli Use, 8.0 1.2 2.4 6 12 24 36481 2 N mm mill UIIIIIIIiIP! mill !iLIItIP"•' '1011EN liiElIiUli_____ I I I f 6 810 2040 h El Shelf Life & Storage - 100 80 C ; 60 t 40 t' 0. c. 0 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) - V rglsnot - ..... -ii ii ioo°#.oicapa _ .JJ_is required. • 5°C t Charngbefore 0 us (4 F) Isnecessary II - - °S full capacity, - - - I 11Chmayi Is restore full capaty Os not - 40 C - 30 C - - I - 20°C I - - -(104°F) _(86°F) lelbattedesre this state. Discharge Time vs. Discharge L I Current - 2 MA 30 10 (104°F) (68°F) 1' I (32°F) F1 I 1 0.45 0.90 1.8 4.5 9.0 18 Discharge Current (A) Cycle Applications: Limit initial current to 27A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 olts until current drops to under 90mA. Battery is fully charged under these 4t conditions, and charger should be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 4 3.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its àurrent level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is 'imperative that they be charged within 6 months of storage, otherwise permanent iloss of capacity might occur as a result of sulfation. .wer-Sonic offers a wide range of chargers suitable for batteries up to 100AH. lése refer to the Charger Selection Guide in our specification sheets for °C-Series [Sv'itch Mode Chargers" and "Transformer Type A and F Series. Please contact our Technical department for advice if you have difficulty in locating suitable models. DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Fax: +1-619-661-3650 • Fax: +1-619-661-3648 Fax: +1-619-661-3648 - national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154° USA ° Tel: +1-619-661-2020 • Fax: RNATIONAL SALES ;tt 1-650-364-5001.., 1° +t-65&366-3662 , a' ir/@power.sonic.comE 350 40811M -• 10 UI' Ira MEN i logo KIN I,,_ IS ______ _