Loading...
HomeMy WebLinkAbout6026 GATEWAY RD; ; FPC2018-0244; Permit'(/0'7~ C ity of PERMIT REPORT Carlsbad Print Date: 09/23/2021 Permit No: FPC2018-0244 Job Address: 6026 GATEWAY RD, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 07/30/2018 Valuation: $0.00 Lot #: Issued: 11/30/2018 Occupancy Group: Project #: DEV12023 Finaled Close Out: 09/23/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI - UNDERGROUND BLDG #16 Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 90621-2525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $136.00 FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $892.00 Total Payments To Date: $892.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - - Fire Protection by Computer. Design Cal-West Fire Protection 1113 N Gates St. Santa Ana, Ca. 92703 866-374-9378 Job Name : Uptown Bressi 'Bldg. #16' Building Location : El Fuerte St. & Gateway Rd. System Contract : 18-099 Data File Bldg. - 16.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cal-West Fire Protection Page 1 Uptown Bressi "Bldg. #16 Date 7.19.18 City Water Supply: Demand: Cl - Static Pressure : 100 Dl - Elevation : 1.516 C2 - Residual Pressure: 20 D2 - System Flow : 500 C2 - Residual Flow : 2500 D2 — System Pressure : 18.457 Hose ( Demand) D3 — System Demand : 500 Safety Margin : 77.469 150 140 130 p120 p110 E10° . 90 S S 80 U 70 R60 E 50 40 30 20 : :zY2 . a I I a,wa1 30O"600 900 1200 1500 1800 2100 2400 2700 FLOW( N"1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cal-West Fire Protection Page 2 Uptown Bressi Bldg. #16" Date 7.19.18 Filling Legend Abbrev. Name Y. % 1 1% 11/2 2 2.4 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Filling generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure I Flow Summary - STANDARD Cal-West Fire Protection Page 3 Uptown Bressi Bldg. #16" Date 7.19.18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. BOR 0.5 0.0 na 500.0 UG1 -3.0 2.89 na UG2 -3.0 7.69 na UG3 -3.0 16.28 na SRC -3.0 18.46 na The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cal-West Fire Protection Page 4 Uptown Bressi "Bldg. #16" Date 7.19.18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00 to 120.0 0.0 13.167 1.516 UG1 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25 UG1 0.0 4.23 3E 57.67 71.000 2.888 to 150.0 0.0 57.670 0.0 UG2 500.0 0.0373 0.0 128.670 4.804 Vel = 11.42 UG2 0.0 4.1 3E 49.537 10.000 7.692 to 150.0 Zif 0.0 49.537 6.000 * * Fixed Loss = 6 UG3 500.0 0.0435 0.0 59.537 2.589 Vel = 12.15 UG3 0.0 4.23 G 3.845 16.000 16.281 to 150.0 T 38.446 42.290 0.0 SRC 500.0 0.0373 0.0 58.290 2.176 Vel = 11.42 0.0 500.00 18.457 K Factor= 116.38 Computer Programs by Hydratec Inc. Revision: 50.52.1 A-2102 Wafer Check Valve 4', 6', 8' 175 psi (1207 kPa) Working Pressure 350 psi (2413 kPa) Test Pressure Listed by Underwriters Laboratories, Inc. and Approved by Factory Mutual Research Corporation. PARTS LIST Catalog Parts Description Number Material Material Standard CW-1 Seat Ring Cast Bronze ASTM B584 CW-2 Body Cast Iron ASTM A126 CW-3 0-Ring (2 req'd) Buna-N ASTM D2000 CW-4 Clapper Cast Bronze ASTM B584 CW-5 Bushing (2 reqd) Brass ASTM B16 CW-6 Spring Stainless Steel Type 302 CW-7 Hinge Pin Stainless Steel Type 303 CW-8 I Seal, Seat EP Rubber ASTM D2000 FBH WAFER CHECK VALVE WEIGHTS 4 6 8 Lb 15.75 22.50 36.50 Kg 7.14 10.21 16.56 C-1 WAFER CHECK VALVES Rev. 2-03 II L I [Mueller Co.] UL /FM FIRE PROTECTION PRODUCTS CW-1 CW-8 CW-7 DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES Size DIMENSIONS In. A (mm) In. B (mm) C In. (mm) In. D (mm) In. E (mm) 4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102) 6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154) 8 4.25 (108) 1.92 (49) 1 11.00 (279) 1 6.00 (152) 1 7.98 (203) WAFER CHECK VALVE ORDERING INFORMATION Specify: Quantity, Size and Catalog Number. WAFER CHECK VALVE PARTS ORDERING INFORMATION Specify: Quantity, Catalog Number, Part Name, Size of Valve, Catalog Number of Valve and Year Date of Valve. Page C-1-6 No. 135 0 CARLSBAD FIRE DEPARTMENT Fire Prevention Division - 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Sprouts Farmers Market SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6217 El Fuerte St CITY: Carlsbad PHONE: ( 714) 914-4552 (Cal-West Fire) FAX NUMBER: ( 714 ) 912-4641 Largest Building (ft.2): 26,000 Sprinkled? Yes Construction Type: LINK SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable): H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet Date/Time ofTest: _.•1 Pitot TubeReading: PSI Corresponding Flow:_______ GPMi ________ Total Flow: 8,000 GPM Residual Pressure 110 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature:_____________________________________ T'tle/OrgI ect Manager Date: 01/11/2018 I I I N + Legend I w_Hydrant Pipe ZONE 8" -550 -700 a 8. 30- "44041.4RAIRPORr" 30. — I IN 30" I1. Fire Flow Test Location H20910 F-I --1 L-1 -------------------------- GATEWAY RD 12" a 12" LEIGHTON CR a 8" L*RTINGTONWY 12" Y 0 cc 0 iiiKC L..A MEDA CR 'N II 12 Sprouts Farmers Market - Fire Flow Analysis MJ Accessories ANSI/AWWA C111/A21.11 O.D. I B.C. JIiJPI.Li NOM SIZE YIIIW.WDJ . . OD A B I.D.ID. c OLT B.C. HOLE BOLT QTY WT (LBS.) 2 6.12 0.62 1.18 3.40 2.61 4.75 00.75 2 - 1 3 7.69 0.62 1.37 4.84 4.06 6.19 00.75 4 5 4 9.12 0.75 1.50 5.92 4.90 7.50 00.88 4 6 6 11.12 0.88 1.63 8.02 7.00 9.50 00.8B 6 10 8 13.37 1.00 1.75 10.17 9.15 11.75 00.88 6 14 10 15.62 1.00 - 1.75 12.22 11.20 14.00 00.88 8 20 12 17.88 1.00 1.75 14.32 13.30 16.25 00.88 8 2.4 14 20.25 1.25 2.00 16.40 15.44 18.75 00.88 10 45 16 22.50 1.31 2.06 18.50 17.54 21.00 00.88 12 55 lB 24.75 - 1.38 - 2.13 20.60 19.64 23.25 00.88 12 55 20 27.00 1.44 2.19 22.70 21.74 25.50 00.88 14 66 24 31.50 1.56 2.31 26.90 - 25.94 30.00 00.88 16 - 90 30 39.12 2.00 2.75 33.29 32.17 36.88 01.13 20 220 36 46.00 2.00 2.75 39.59 38.47 43.75 - 01.13 24 286 42 53.12 2.00 2.75 45.79 44.67 50.62 01.38 28 288 48 60.00 2.00 2.75 52.09 50.97 57.50 01.38 32 400 O.D. B.C. I.D. C IJ[ OVERSIZE 1 NOM. SIZE . O.D. B C I.D.B.C.BOLT HOLE BOLT QTY WT (LBS.) 4 9.12 0.75 1.50 5.92 5.10 7.50 00.88 4 3 6 11.12 0.88 1.63 8.02 - 7.20 9.50 00.88 6 - -5 8 13.37 1.00 1.75 10.17 9.40 11.75 00.88 6 6 10 15.62 1.00 1.75 12.22 11.50 14.00 00.88 8 8 12 17.88 1.00 1.75 14.32 1 13.60 16.25 00.88 8 9 16 22.50 1.31 2.06 18.50 17.94 21.00 00.88 12 14 Page 15 REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPOIATE TOU. FREE I.ECO.999.3E19FAX l8I.SS8. ~0,~ JMagIe Building essentials for a better tomorrow BLUE BRUTE TIVI SUBMITTAL AND DATA SHEET - I.D. : Inside Demeter O.D. Outside Diameter 1P T. Wall Thickness D9 Bell Outside Diameter E: Distance between Assembly Mark to the end of spigot. O.D. E PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 0.528 8.80 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 1 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0.943 8.80 16.97 25.1 Consult JIM Eagle" for CSA and other listing availability prior to shipment. Note: FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JIM eagleTM sales representative for location availability. Assembly Mark Product Standard: ANSI/AWWA C900 Pipe Compound: ASTM Dl 784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JIM Eagle' Installation Guide JM Eagle1M also manufactures this pipe in green for sewer force main applications and purple, specifically for reclaimed water systems. This pipe is made to the same requirements as our standard products. The only difference is that the pigment used is green or purple. These products will not be marked with UL or NSF listing marks. Additionally, the green pipe will be marked "Forced Sewer" and the purple pipe will be marked: "Reclaimed Water.. Do Not Drink.' Job Name _______________________________________ Contractor Job Location Approval Engineer Contractors P.O. No. Approval Representative - MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/211 - 811 (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (ie., pollutant) application in accordance with Local Governing Water Utility Code. This Backfiow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4 Backflow Assembly No Special Tools Required for Servicing Reid Replaceable Seats & Discs Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by A\AMIA Standard C510. The auxiliary bypass line contains a 5/8"x3/4" Water Meter that complies with ANSI/A\MNA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWINA Standard C510 flow and pressure loss performance parameters. NOTICE I The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. i1ItI Inquire with governing authorities for local installation requirements Detect Potential Underground Water Leaks "The wetted surface of this product contacted by consumable Detect Unauthorized Water Usage water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are prodded for reference only. For precise measurements, pioase contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, nsisfructiai, specifications, or materials with- out prior notice and withwt incurring any ohtitlon to make such changes and modifications on FEBCO products previously or subsequently sold. A WAITS Brand Options - Suffix OSY: UL/FM Approved OS&Y Gate Valves [ANSI!A'VWVA 0515 Compliant] CFM: Totalizing Cubic feet/mm 5/a'x 3/4' Water Meter [ANSI! AWvVA 0700 Compliant] GPM: Totalizing Gallons/mm 5/8"x 3/4' Water Meter [ANSI! A\MNA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME B16.1 Class 125 & AW/A Class D Range] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AWVAC111!A21.11] MJ x FL - Mechanical Joint x Range [A'MNA C1 1!A21.11; ASME B16.1 Class 125/AVWVA Class D Range] FL x FL - Range x Flange [ASME B16.1 Class 125 & AWVVA Class D Range] Materials Below is a general materials list of the Model LF876V All assemblies size 21h' through 8" is similar in materials and construction. Please contact your local FEBCO Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external A\MNA C550-90 Shutoff Valves: OSY resilient wedge gate valve A\MNA C515 (UL/R\4) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: A\AM/A C606 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO!cUPC A\MNA Standard 0510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Range **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2" - 8") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 21/2 - 8') - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO!cUPC ® <S:; ss, Approved US 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175psi (12.1 bar) Min. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350p5i (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Dimensions - Weights Size: 21/211 - 8" Below are the nominal dimensions and physical weights for the Model LF876V size 21h" through 8. Allowances must be made for normal manufacturing tolerances. Please visit our websfte to download a copy of this products installation instructions, or contact your local FEBCO Representative for more informaon. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V ME [(oN) DIMENSIONS ... WEIGHT in. mm A in. mm B in. mm in. C mm D in. mm E in. mm F in. mm in. G mm in. U mm in. mm J in. mm in. mm L in. mm MY lbs. kg. 21/2 65 291/a 740 121/2 318 61/4 159 251/ 642 171/2 445 135/8 346 271/4 692 51/2 140 111A 283 31/2 89 163/8 416 111/2 292 216 98 3 80 291h 740 121/2 318 61/4 159 25Y4 654 173/4 451 141A 359 281/4 718 51/2 140 111A 283 3Y4 95 221/4 565 111h 292 242 110 4 100 311/8 791 14 356 7 178 27Y4 705 18Y4 476 151/2 394 31 787 6 152 11½ 283 41/2 114 231/4 591 13 330 347 157 6 150 353/4 908 16 406 8 203 32% 831 221/8 562 18% 473 371/4 946 71/4 184 121h 316 51/2 140 30Y8 765 13 330 529 240 8 200 1 4Q3/4 10351 181/2 470 9¼ 235 363/4 933 1 25½ 638 203/4 527 1 411/2 1054 81/2 216 14 356 1 63/4 172 37Y4 959 141/2 368 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backflow Assemblies with specified Gate Valves H ) Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AWWA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 0fps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Pipe Support (furnished by customer) for valve weight only. Vertjc2l Orientation 2-Pattern" Raw curve z Standard Orientation "N-Pattern Flow curve N Capacfty N-Pattern 2½" LF876V S1 Service Flow Rated flow Ill Rated flow 22 20 I 18 I 16 I r 14 I I r 12 I I _I r — -- I I.- 2 L_. 0 25 50 751001251501752002252502753005350gpm 284 568 852 1136 1pm 7.5 14.7 22.0 fps 3 LF876V psi Service Flow Rated Flow *UL Rated flow V 20 I 18 16 14 a 8 us 12 I r...— 10 - 8 6 4 I.- 2 I I 50 100 379 4" LF876V psi 150 200 757 7.5 Service Flow 250 300 350 1136 14.5 Rated flow 400 450 500 gpm 1514 1pm 22.0 fps lii. Rated flow 18 I I 16 I I 14 12 I I 10 2 --I o I 7 I I 0 100 200 300 379 1136 7.5 400 500 600 1893 12.8 700 800gpm 2650 tom 19.1 fps 6" LF876V psi Service Flow Rated Flow 18 Iii. Rated Flow 16 14 12 I 10 I C2 8 - - ra " 6 -z - - -- - 2 0 I I 0 200 400 757 600 800 1000 1200 2277 3785 7.5 11.4 1400 1600gpm 5300 1pm 17.0 fps 8" LF876V psi Service flow Rated Flow lii Rated flow 18 16 14 12 E 10 m' 8 0 400 800 1200 1600 2000 2400 9pm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBC0onIine.corn Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEB000nhine.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonline.com © 2017 FEBCO ES-A-ln Building Riser Series IBR In-BuildinLy Risers Sizes: 4 - 10 (100— 250mm) = FIRE &WATERWORKS Tr T CAP NOW' CtUDED Features Cost savings Corrosion resistant stainless steel construction, type 304 Ease of installation and light weight allows one person to position and handle the riser Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals Includes Test Cap and Coupler UL/FM approved Sizes: available in 4 - 10 (100-250mm) with various lengths to meet all local requirements Designed to meet NFPA 24-2007 Section 10.6.5 AWWA C900 Inlet/DIP AWWA C606 Outlet Job Name Job Location Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24-2007, the ULJFM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel signifi- cantly increases the reliability and life of the riser. *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Contractor Approval Engineer Contractors P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. Approvals Fittings FM class 1920 UL HKQA(4"-lO') Us L Dimensions - Weights I-1-- A Grooved End J !f (Flange Optional) -I- CIPS Coupling Tie-Rod Bracket C 1P' in. mm A(OD) in. mm B ft cm C ft cm lbs. kg 4 100 41/2 114 6 183 6 183 71 32 6 150 65/8 168 6 183 6 183 98 44 8 200 8/8 219 6 183 6 183 129 59 10 250 1 10/4 273 1 6 183 1 6 183 1 202 92 Consult factory for custom leg dimensions. Standards NFPA - Designed to allow the contractor to conform to NFPA 24-2007 Section 10.6.5: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA 24-2007, 10.1.1, 10.6.7 End Connections Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration 1H1U1j Iitlli] in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 1 11.1 282 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE DESIGN in. mm PROOF psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 800 56 IMPORTANT: Inquire with governing authorities for local installation requirements. A A M E S FIRE &WATERWORKS www.amesfirewater.com 0 A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T: 916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Service Rd. • Burlington, ONT. L7L 5H7• T: 905-332-4090 • F: 905-332-7068 ES-A-IrtBuildingRiser 0935 © 2009 Ames Fire & Waterworks PACIFIC STATES PSCIPCO CAST IRON PIPE COMPANY DIVISION OF McWM4E. INC. P.O. Box 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 601) 373-6910 STANDARDS In each of the following, standards are developed by committees consisting of consumer, general interest and manufacturing members: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) NM 16433(N) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) 61-1989 Factory Mutual (FM) J12VOA8.AH For ready reference, standards for ductile iron pipe are listed below: Standard Designation ANSI/AWWA C150/A21.50 ANSI/AWWA C151/A21.51 ANSI/AWWA C11O/A21.1O ANSI/AWWA C153/A21.53 ANSI/AWWA C111/A21.11 ANSI/AWWA C115/A21.15 ANSI/AWWA C104/A21.4 ANSI/AWWA C105/A2 1.5 & ASTM A674 ANSI/AWWA C600 ASTM A746 NFPA Outside Protection 24 Subiect Covered Design Water Pipe Fittings - Cast Iron Fittings - Ductile Iron Rubber - Gasket Joints Flanged Pipe Cement - Mortar Linings Polyethylene Encasement for Ductile Iron Pipe Installation Gravity Sewers Fire Protection Piping Pacific States ductile iron pipe meets and exceeds the requirements of all of the above national standards relating to pipe manufacture and performance. PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWANE, INC. P.O. BOX 1219, PROVO, UTAH 84803 TELEPHONE (AREA CODE 801) 373-6910 FAX: (801) 377-0338 EMAIL: sales@pscipco.com WEBSITE: www.pscipco.com WW Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness. Nominal Wt. of Barrel Mechanical Joint Wt. of Wt. Per Avg. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.t Per Ft4 Size Class In. In. Lb. Lb. Lb. Lb. 3 53 .31 3.96 10.90 11 230 11.4 4 53 .32 4.80 13.80 16 290 14.6 6 53 .34 6.90 21.40 18 405 22.4 8 53 .36 9.05 30.10 24 565 31.4 10 53 .38 11.10 39.20 31 735 40.9 12 1 53 1 .40 1 13.20 1 49.20 1 37 1 925 1 51.3 tlncluding bell; calculated weight of pipe rounded off to the nearest 51b Tolerances of OD of spigot end; 3-12 in. ±0.06 in. Including bell; average weight per foot, based on calculated weight of pipe before rounding. .Visit our website at www.kennedyvalve.com K KENNEDY VALVE A DIVISION OF MCWANE, INC I ASSOCIATED WITH AWWA. NSF AND ULM A l - : I 1- tT' I During the decade of the 1980's, the waterworks industry was introduced to the Resilient Seated Gate Valve, a design principle that is dominant in preference for use in distribution systems. Kennedy Company was at the forefront in this industry-wide movement by introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve. In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the model KS-FW. The goal of the redesign was to eliminate the customer need for any anti- rotational bolts. Kennedy did this by designing a machined elliptical bolthole in place of an as-cast opening. This elliptical design allows valve installers to slide a standard sized bolt into the slot, therefore eliminating the need to have two different types of bolts on the installation. RECOMMENDED SPECIFICATIONS FOR C-509 CAST IRON RESILIENT WEDGE GATE VALVES KENNEDY VALVE COMPANY Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves for all water supply service. The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally encapsulated with rubber. The sealing rubber shall be permanently bonded to the wedge per ASIM D429. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. Blind bolts shall not be allowed. The valves shall be either non-rising stem or rising stem, opening by turning left or right, and provided with 2" square operating nut or a handwheel with the word "Open" and an arrow to indicate the direction to open. Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts independent of wedge and of stem (in NRS valves). Stainless stems are available but not standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. The NRS stems on 2"-12" shall also have two low torque thrust bearings located above and below the stem collar to reduce friction during operation. Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions in the seat area. Tapping valves 4" and larger shall accept a full size tapping cutter. The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor- dance with AWWA C550. Each valve shall have manufacturers name, pressure rating, and year in which it was manu- factured cast in the body. Prior to shipment from the factory, each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable). Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Kennedy Valve Company. (Revised 03-27-2011) hl wl' I I Ll fi My EN m "u I , E I I NAWWWA. I I R SWAYMAN MY& - 9 =7111 41 t DELRIN THRUST BEARINGS ABOVE AND BELOW THE THRUST COLLAR REDUCE FRICTION AND MINIMIZE OPERATING TORQUES THE OPERATING MECHANISM IS TRIPLE 0-RING SEALED TO COMPLETELY SEAL AGAINST LEAKAGE PAST THE STEM. TWO 0-RINGS ARE PROVIDED ABOVE THE LONG, TROUBLE FREE LIFE WITH :.. THRUST COLLAR AND ONE BELOW. HIGH STRENGTH, NON-CORRO- UPPER 0-RINGS CAN BE REPLACED SIVE BRONZE STEM AND STEM UNDER PRESSURE WITHOUT REMOVING NUT. ' THE STEM WHEN THE VALVE IS FULLY I OPENED. ALL NRS STYLE VALVES ARE STAIN- O-RING SEALS AT STUFFING BOX LESS .. .AND BONNET TO BODY FLANGES TO ENSURE THE BEST POSSIBLE SEAL. NO FLAT GASKETS. ri ci ;i 100% EPDM COATED I -- - '. . KENNEDY CORROSION WEDGE WITH TWIN SEAL ... .: - RESISTANT FUSION DESIGN ENSURES BUBBLE- BONDED EPDXY COATING, TIGHT SEAL UP TO 250 PSI . . : CONFORMING TO AWWA • EVERY TIME. . C-550 AND NSF61 • • CERTIFIED, PROTECTS BOTH INSIDE AND ELLIPTICAL BOLT OUTSIDE OF VALVE. HOLE DESIGN - .• ELIMINATES THE NEED FOR ANTI-ROTATION . BOLTS • . 'I SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE FREE OF POCKETS, CAVI- IN UPRIGHT POSITION TIES, AND DEPRESSIONS FOR EASIER STORAGE ALLOWING FOR MINIMAL AND PROTECTION FROM FLOW LOSS AND LOWER THE ELEMENTS. PUMPING COSTS. ALL TAPPING VALVES ALL VALVES ARE RATED AT 250 PSI FOR 10 YEAR LIMITED WARRANTY ACCEPT FULL SIZE AWWA SERVICE AND 200 PSI FOR TAPPING CUTTER. ULFM SERVICE. ALL VALVES ARE HYDROSTATICALLY TESTED TO 500 PSI. (Revised 03-27-2011) 6F 8571 8561 8057 8572 MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ 2'.12" 2" • 12 2'. 3" 3"" 12" 1 IF 8597 8576 8901 8701 PUSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS 2" • all CUTTING-IN JOINT PUSH-ON FOR (DL & C900) POST INDICATOR VALVE (PIV) 4" • 12" 4".12" 3"• 12" 0 I] (o 8902 8950 8071 8068 FLANGED & TYTON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS PUSH-ON FOR (D.I. & C900) TAPPING VALVE POST INDICATOR VALVE (PlY) OS&Y CONSTRUCTION 4" • 12" 4" • 12" 3" • 12" 2112" • 12" A B C D E G H P Q P S U V No I Turns 1. F-tol Open 2" 7 3 1/4 - 51/4 10 7/8 - - 3 - - 71/4 - - 43/4 2 1/2' 7 1/2 - - 7 11 3/8 - - 31/4 163/8 13 7/8 7 1/4 - - 51/2 3' 1 8 31/2 1 - 7 1/8 123/8 1 - 5 3/41 3 1/2 18 7/8 115 5/8 10 1 - - 10 4" 9 41/2 63/4 - 143/4 41/2 6 3/4 4 1/2 223/4 18 1/4 10 63/4 93/4 13 1/2 6" 10 1/2 5 77/8. - 19 51/4 7 3/4 5 301/8 23 3/4 12 75/8 11 3/16 19 1/2 5" 111/2 51/2 81/2 - 221/2 5 5/8 8 1/2 51/2 373/4 29 1/4 14 81/2 113/4 251/2 10" 13 7 10 - 261/2 7 10 - 453/4 353/8 18 10 131/2 311/2 IT 1 14 63/4 1 111/4 - 30 81/2 107/8 1 - 531/8 405/8 18 11 143/4 1 373 "V KENNEDY VALVE A DIVISION OF MCWANE, INC. www.kennedyvalve.com 2007 1021 E. Water Street Elmira, New York 14901 P.O. Box 981 Phone (607) 734-2211 Fax 1-607-734-3288 (Revised 03-27-2011) MJ Accessories ANSI/AWWA C111/A21.11 MECHANICAL NOM. SIZE -JOINT GASKET PIPE A O.D. B C CD I I 28 for sizes 3-24 in. F 20 for sizes 30-60 in. OD j E F G 2 2.50 0.48 0.62 0.31 2.48 0.12 0.15 1.05 3 3.96 0.48 0.62 0.31 3.86 0.12 0.15 1.05 4 4.80 0.62 0.75 0.31 4.68 0.16 0.22 1.22 6 . 6.90 0.62 0.75 0.31 6.73 0.16 0.22 1.22 8 9.05 0.62 0.75 0.31 8.85 0.16 0.22 1.22 10 11.10 0.62 0.75 031 10.87 0.16 0.22 1.22 12 13.20 0.62 0.75 0.31 12.95 0.16 0.22 1.22 14 15.30 0.62 0.75 0.31 14.99 0.16 0.22 1.22 16 17.40 0.62 0.75 0.31 17.07 0.16 0.22 1.22 18 19.50 0.62 0.75 0.31 19.13 0.16 0.22 1.22 20 21.60 0.62 0.75 0.31 21.20 0.16 0.22 1.22 24 25.80 0.62 0.75 0.31 25.34 0.16 0.22 1.22 30 32.00 0.73 1.00 0.38 31.47 0.16 0.37 1.54 36 38.30 0.73 1.00 0.38 37.67 0.16 0.37 1.54 42 44.50 0.73 1.00 0.38 43.78 0.16 0.37 1.54 48 50.80 0.73 1.00 0.38 49.98 0.16 0.37 1.54 r _( 4 OD A _I T c8f G Ii NOM. SIZE TRANSITIONiMECHANICAL-JOINTdGASKET PIPE O.D. A B C(REF) OD *1 % E F G 2 2.375 0.56 0.66 0.31 2.32 0.12 0.21 1.10 3 3.500 0.72 0.64_ 0.34 3.43 0.12 0.38 1.10 4 4.500 0.76 0.73 0.33 4.43 0.20 0.37 1.26 6 6.625 0.75 0.73 0.32. 6.53 0.20_ 0.36 1.25 8 8.625 0.82 0.73 0.34 8.50 0.20 0.43 1.27 10 10.750 0.79 0.75 0.31 1039 0.20 0.39 1.26 12 12.750 0.84 0.75 0.33 12.56 0.20 0.44 1.28 UCAT.I4I REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPORATE _TOLL FREE I-SOO.999.3I9FAX 28I.558.9O Page 17 MJ Accessories ANSI/AWWA C111/A21.11 1-Bolts, Double Ended Rods & Nuts HS LA STEEL SPECIFICATIONS: Bolts & Nuts are manufactured in accordance with ANSI / AWWA Clii / A21.1 1. Material is High Strength Low Alloy Steel per ANSI/AWWA C111/A21.11. Threads per ASME B1.1 unified standard coarse (Class 2A & 28) MECHANICAL PROPERTIES Yield Strength 45000 PSI (mm) Elongation in 2in. 20% (mm) BLUE BOLT/NUT/ROD CHEMICAL PROPERTIES Carbon 0.20% Max Manganese 1.25% Max Sulfur 0.05% Max Nickel 0.25% Mm Copper 0.20% Mm Combined 1.25% Mm (Ni. Cu, Cr) T-Bolts, Rods & Nuts have fluoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: Number of Coats: Adhesion: Cure Test: Pencil Hardness: Volatile Organic Compounds 0.3 to 0.4 mil per coat 3 to 4 coats 1 mm cross hatch test + 5 Pulls. Good knife resistance 50+Rubs with MEK. No substrate exposure Pencil Hardness: 4-611 2.741bs/gal Stainless Steel 1-Bolts & Nuts ALLOYS SS 304 & SS 316 PER ASTM F593 SPECIFICATIONS: 1-bolt dimensions are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. 1-bolt alloys SS 304 and SS 316 per ASIM F593 Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594. MECHANICAL PROPERTIES Tensile Strength: 85,000 PSI to 140,000 PSI Yield Strength: 45,000 PSI (mm) COATING SPECIFICATION Nuts have fluoropolymer coating material which is VOC-Compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal Adhesion: 1mm cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green, SS 316 is red A. AWWA MEMBER UCAT.I4I REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPORATEITOLI. FREE I.RRO.999.MA9 P4X181.558.9000 19 Page 18 PIPE SIZE (IN) iIHANICAL JOINTI:1.IlIC.)t.1!11 BOLT SIZE RANGE OF (IN) TORQUE (FT-LBS) 2-3 5/8 45-60 4-24 3/4 75-90 30-36 1 100-120 42-48 11/4 120-150 'These torque ranges are requirements ofA WW4 C600 Accessories ANSI/AWWA C111/A21.11 1/8-in. Radius Maximm T r B Ll_,~ R t *j 0 - - - - -Minimum 1l16-inx45Chamfei-. 8/2 HEAD (LOW NOM. SIZE ALLOY& A B C D THREADS PERIN. F H R 5Ax3 1.50 0.625 3.00 2.00 11 0.625 1.062 0.625 0.312 x3 Vi 1.50 - 0.625 3.50 2.70 11 0.625 1.062 0.625 0.312 1/4x3 ½ 1.75 0.750 3.50 2.50 3.00 10 0.750 1.250 0.750 0.375 1/4 x 4 1.75 - 0.750 4.00 - 10 0.750 1.250 0.750 0.375 1/4x41/a 1.75 0.750 4.50 3.00 10 0.750 1.250 0.750 0.375 ~xS 1.75 - 0.750 5.00 3.00 10 0.750 1.250 - 0.750 0.375 1/4x5'/a 1.75 0.750 5.50 3.70 10 0.750 1.250 0.750 0.375 1x5½ 2.25 1.000 5.50 3.00 8 1.000 1.625 1.000 0.500 1x6 2.25 1.000 6.00 3.00 8 1.000 1.625 1.000 0.500 1',4x6 230 1.250 6.00 3.00 7 1.250 2.000 1.250 0.625 1%x6½ 2.50 1.250 6.50 3.50 7 1.250 2.000 1.250 0.625 1¼x8'/x 2.50 1.250 8.50 3750-1 7 1.250 2.000 1.250 0.625 rsnhlftl~~ No's NOM. SIZE ANTI-ROTATION A (LOW B ALLOY STEEL) C LI.)uIU k[S1 D E THREADS PERIN. F H J R 'Ax3 130 0.625 0.625 3.00 3.50 2.00 0.63 11 0.625 1.062 0.625 0.312 5/ax3½ 1.50 230 0.63 11 0.625 1.062 0.625 0.312 Nx31/2 1.75 0.750 3.50 2.50 0.63 10 0.750 1.250 0.750 0.375 Y4x4 1.75 0.750 4.00 3.00 0.63 0.63 10 0.750 0.750 1.250 1.250 0.750 0.375 Nx4½ 1.75 0.750 4.50 3.00 10 0.750 1 0.375 ~x5 1.75 0.750 5.00 3.00 0.63 10 0.750 1.250 0.750 0.375 LICAT.I4EI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPOIATE TOLL FREE 1.IRR.999.3(4)9 FAX 181.558.9m1) j Page 19 . 40' T U A R NOM SIZE BENDS T BENDS (1/4) WT A R (LBS.) BENDS WT A R (LBS.) BENDS QA6) WT A R (LBS) A BENDS (1/32) WT Il (LBS.) 2 0.39 3.25 2.25 14 1.80 1.96 13 1.80 4.02 13 1.80 8.12 13 3 0.48 5.50 4.00 35 3.00 3.62 30 3.00 7.56 30 3.00 15.25 30 4 0.52 6.50 4.50 55 4.00 4.81 50 4.00 10.06 50 4.00 20.31 50 6 0.55 8.00 6.00 85 5.00 7.25 75 5.00 15.06 75 5.00 30.50 7S 8 0.60 9.00 7.00 125 5.50 8.44 110 5.50 17.62 110 5.50 35.50 110 10 0.68 11.00 9.00 190 6.50 10.88 155 6.50 22.62 160 6.50 45.69 160 12 0.75 12.00 10.00 255 7.50 13.25 215 7.50 27.62 220 7.50 55.81 220 14 0.66 14.00 11.50 340 7.50 12.06 270 7.50 25.12 275 7.50 50.75 275 16 0.70 15.00 12.50 430 8.00 13.25 340 8.00 27.62 345 8.00 55.81 345 18 0.75 16.50 14.00 • 545 8.50 . 14.50 420 8.50 30.19 430 • 8.50 60.94 430 20 0.80 18.00 1530 680 9.50 16.88 530 9.50 35.19 535 9.50 71.06 540 24 0.89 22.00 18.50 1025 11.00 18.12 755 11.00 37.69 765 11.00 76.12 770 30 1.03 25.00 21.50 1690 15.00 27.75 1380 15.00 57.81 1400 15.00 116.75 1410 36 1.15 28.00 2.4.50 2475,,, 18.00 35.00 2095 18.00 72.88 2135 18.00 147.25 2145 42 1.28 31.00 27.50 3410 21.00 42.25 2955 21.00 88.00 3020 21.00 177.69 3035 48 1.42 34.00 30.50 4595 24.00 4930 4080 24.00 103.06 4170 24.00 208.12 4190 NOM. T SIZE 'A B R , I WT (LBS.) I A WT B R (LBS.) A B R WT . (LBS.) WT A B R (LBS.) 3 04.8 5.50 13.50 4.00 35 3.00 11.00 3.62 30 3.00 11.00 736 30 3.00 11.00 15.25 30 4 0.52 630 14.50 430 50 4.00 12.00 4.81 45 4.00 12.00 10.06 45 4.00 12.00 20.31 45 6 0.55 8.00 16.00 6.00 80 5.00 13.00 7.25 70 5.00 13.00 15.06 70 5.00 13.00 30.50 70 8 0.60 9.00 1700 7.00 120 S.50 1350 8.44 105 5.50 1350 2 105 5.50 1330 3530 105 10 0.68 711 0-0 19.00 9.00 190 6.50 14.50 10.88 155 6.50 14.50 22.62 160 6.50 14.50 45.69 160 12 075 120020001000 255 750 1550 13.25 215 750 15.50.2762 220, 750 15505581220 14 0.66 14.00 22.00 11.50 325 7.50 15.50 12.06 255 7.50 15.50 25.12 260 730 15.50 50.75 260 16 0.70 15.00 23.00 1230 410 8.00 16.00 13.25 320 8.00 16.00 27.62 325 8.00 16.00 55.81 325 24 0.89 22.00 30.00 18.SO 985 11.00 19.00 18.12 715 11.00 19.00 37.69 725 23.00 57.81 1295 - 11.00 15.00 19.00 76.12 730 30 1.03 25.00 33.00 21.50 1585 15.00 23.00 27.75 1275 15.00 23.00 116.75 1305 36 1.15 28.00 36.00 24.50 2310 18.00 26.00 35.00 1930 18.00 26.00 72.88 1970 18.00 26.00 42 1.28 31.00 -MO 0 27.50 3200 21.00 147.25 L. 1980 29.00 42.25 2745 21.00 -79 0-0 88.00 2810 21.00 29.00 177.69 2825 UCAT.I4eI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAK PIPE PRODUCTS HOUSTONCORPORATEITOLL FREE I.REI.999.3009 F4X28I.558.9000 FM4pRIth Page 22 II GUARDIAN I 1fl7J) FIRE EQUIPMENT, INC. DETAIL AND SUBMITTAL SHEET MIAMI, FL Ph. 800.327.6584• Fax 800.827.3869 6300 Series Fire Dept. Inleths.ii.flh.].- Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: lAppropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (minimum), per 21/2" inlet. Two and three-way - inlet connections feature clappered brass bodies (straight or angle pattern), with female hose thread swivel inlets and female outlets. Cast brass construction, standard. Model No. 0 6314* Outlet Back Two Iand Three-Way Size 4" x 21/2" x 21/2" Clappers 1 A 51/2" B 81/e" 06315* Angle 4" x 21 /2"x 21/2" 1 81/8" 8l4" E] 6324 Back 4" x 21 /2" x 21/2" 2 71/4" 101/2" 0 6325 Angle 4" x 21/2" x 21/2" 2 81/4" 101/2" E] 6326 Back 6" x 21/2" x 21/2" 2 71/4" 101/2" 0 6327 Angle 6" x 21/2" x 21I2" 2 10" 101/2" 0 6336 Back 6" x 21/2" x 21/2" x 21/2" 3 10V2" 13/4" E] 6337 Angle 6" x 21/2" x 21/2" x 21/2" 3 111/2" 141/2" Body Lettering 0 AUTO SPKR DSTANDPIPE E] Blank (unlettered) *Auto Spkr lettering only Optional Finish:[] -13 Polished Brass Threads: 0-c Rough Chrome Plated 0 NST 0 -D Polished Chrome Plated 0 Other Plugs with Chains and Break Caps - Used to keep fire dept. inlet connections free of debris and protect female threads. Plugs with Chains IIVIQUI r'u. I uze uype Optional Finish: 0-B Polished 0-C Rough Chrome Plated 0 -D Polished Chrome Plated Break Caps 0 T64*06 7121h' 1 Aluminum 6407 1 2h' astic Threads: Adjustable Plugs ONST .16 0 Other 0 6408 2'/2" Aluminum 0 6409 21I2 Plastic Contact factory for current listings and approvals 1