HomeMy WebLinkAbout6010 AVENIDA ENCINAS; ; AS070009; PermitUlty 01 Uarlsbad Sprinkler Permit Permit No: AS070009 6010 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: SPRINK Applied 1/18/2007 Parcel No: 2110302800 . Approved: 1/18/2007 .Lot#: 0 Reference No.: Issued: 1/18/2007 PC #: Inspector: Project Title: 'AUTO DEALERSHIP THREE FIRE SPRINKLER INSPECTIONS @ $62/EA Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000' Owner: 6010 AVEN IDA ENCINAS PARTNERS L L C P0 BOX 231594 ENCINITAS CA Fees ($) , Add'I Fees ($) , Total ($) ' Balance ($) 186 ' 0 186 0 Pb -. APPROVED APPROVED AS NOTED 0 NOT APPROVED, RESUBMIT CHECKING IS ONLY FOR COFORMAN WiTH T1E DtSIGN GkCLrI 'Jt rUE PROJECT AND COMPLIANCE WITH THE IFOAT!D' CNEN IN THE CONTRACT OOCM ENTS. CONTRACTOR IS RESPONSIBLE f'jR WMNSIO?S TO BE CONFIRMED 0 C0RFELA1ED AT THE JOB 'I( AND FOR COORDINATION OF THE "h OF ALL TRADES APPROVED CBADPEPATMENT - - - Fire Protection by Computer Design COSCO FIRE PROTECTION, INC. 10695 Treena Street Suite 105 San Diego, CA 92131 858-444-2000 Job Name Auto Dealership Building Location 6010 Avenidas Encinas, Carlsbad, California System Contract Data File : FP-3.wxl ri=-o 6 , tp'~ a 0 5. Id Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 pt, COSCO FIRE PROTECTION, INC. Page Auto Dealership Date 122006 Hydraulic Design Information Sheet Name - Auto Dealership Date - 12/20/06 Location - 6010 Avenidas Encinas, Carlsbad, California Building - System No. - Contractor - Owner Contract No. - Calculated By - D. Wilson Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 15'-0" Occupancy - Extra Hazard Group 1 S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 (X) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sorinkler Ooer.tinn - 2Sflfl -- Density -- - .30 (X) Wet Make Viking D Area Per Sprinkler - 100 max ( ) Dry Model Micromatic E Elevation at Highest Outlet - 141 -0" ( ) Deluge Size 3/4" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 8.0 I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.286 G Hose Allowance - Outside - 500 No Calculation Flow Required - 1534.72 Press Required - 58.572 @ Source (13) Summary C-Factor Used: Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 11/29/06 Cap. - T Time of Test - 10:00 am Rated Cap.- Elev.- E Static Press - 92 8 Press - R Residual Press - 78 Elev. - Well Flow - 1280 Proof Flow S Elevation - level U P Location - 6010 Avenida Encinas P L Source of Information - Cosco Fire witnessed by Mark Underwood Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) COSCO FIRE PROTECTION, INC. Page 2 Auto Dealership Date 122006 City Water Suppy: Demand: Cl - Static Pressure : 82.8 Dl - Elevation : 5.990 C2 - Residual Pressure: 68.8 D2 - System Flow : 1034.72 C2 - Residual Flow : 1280 D2 - System Pressure : 58.572 Hose ( Adj City) Hose ( Demand ) : 500 D3 - System Demand : 1534.72 Safety Margin : 4.642 150 140 130 p120 R° E10° 590 - 80 - ____ C2 u 70 R 60 - - ___ D2 E ____ _____ ______ . 50 ________ 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO FIRE PROTECTION, INC. Page 3 Auto Dealership Date 122006 Fitting Legend Abbrev. Name /2 11,4 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 65 76 87 98 109 130 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zig Wilkins 375DA Fitting generates a Fixed Loss Based on Flow Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD COSCO FIRE PROTECTION, INC. Page 4 Auto Dealership Date 122006 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 41 13.83 8 20.2 na 35.95 0.3 100 7.0 42 13.83 8 20.29 na 36.03 0.3 100 7.0 39 13.83 8 20.27 na 36.02 0.3 100 7.0 40 13.83 8 20.36 na 36.1 0.3 100 7.0 37 13.83 8 20.4 na 36.14 0.3 100 7.0 38 13.83 8 20.5 na 36.22 0.3 100 7.0 35 13.83 8 20.19 na 35.95 0.3 100 7.0 36 13.83 8 20.28 na 36.03 0.3 100 7.0 28 13.83 8 14.06 na 30.0 0.3 100 7.0 29 13.83 8 14.13 na 30.07 0.3 100 7.0 30 13.83 8 14.37 na 30.32 0.3 100 7.0 31 13.83 8 14.87 na 30.85 0.3 100 7.0 32 12.83 8 16.18 na 32.18 0.3 100 7.0 33 13.83 8 17.09 na 33.08 0.3 100 7.0 34 13.0 21.34 na 21 13.83 8 14.13 na 30.07 0.3 100 7.0 22 13.83 8 14.2 na 30.14 0.3 100 7.0 23 13.83 8 14.44 na 30.4 0.3 100 7.0 24 13.83 8 14.95 na 30.93 0.3 100 7.0 25 13.83 8 15.82 na 31.82 0.3 100 7.0 26 13.83 8 17.17 na 33.15 0.3 100 7.0 27 13.0 21.41 na 14 13.83 8 14.23 na 30.18 0.3 100 7.0 15 13.83 8 14.29 na 30.25 0.3 100 7.0 16 13.83 8 14.53 na 30.5 0.3 100 7.0 17 13.83 8 15.05 na 31.03 0.3 100 7.0 18 13.83 8 15.93 na 31.93 0.3 100 7.0 19 13.83 8 17.28 na 33.26 0.3 100 7.0 20 13.0 21.55 na 1 13.83 8 14.07 na 30.01 0.3 100 7.0 2 13.83 8 14.14 na 30.08 0.3 100 7.0 3 13.83 8 14.38 na 30.33 0.3 100 7.0 4 13.83 8 14.89 na 30.86 0.3 100 7.0 5 13.83 8 15.76 na 31.76 0.3 100 7.0 6 13.83 8 17.1 na 33.08 0.3 100 7.0 7 13.0 21.33 na 8 13.0 27.13 na 9 13.0 27.15 na 10 13.0 27.23 na 11 13.0 27.41 na 12 13.0 32.28 na TOR 12.0 33.3 na BOR 0.0 41.5 na Dl 0.0 42.37 na BFO 0.0 45.62 na BFI 0.0 57.05 na 500.0 13 0.0 58.57 na The maximum velocity is 22.78 and it occurs in the pipe between nodes 20 and 11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final .Calculations - Hazen-Williams COSCO FIRE PROTECTION, INC. Page 5 Auto Dealership Date 122006 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 41 35.95 2.157 0.0 8.000 20.197 K Factor = 8.00 to 120 0.0 0.0 0.0 42 35.95 0.0115 0.0 8.000 0.092 Vel = 3.16 42 36.04 2.157 iT 12.307 4.250 20.289 K Factor = 8.00 to 120 0.0 12.307 0.359 34 71.99 0.0416 0.0 16.557 0.688 Vel = 6.32 0.0 71.99 21.336 KFactor= 15.59 39 36.02 2.157 0.0 8.000 20.270 K Factor = 8.00 to 120 0.0 0.0 0.0 40 36.02 0.0116 0.0 8.000 0.093 Vet= 3.16 40 36.10 2.157 iT 12.307 4.250 20.363 K Factor = 8.00 to 120 0.0 12.307 0.359 27 72.12 0.0417 0.0 16.557 0.691 Vel = 6.33 0.0 72.12 21.413 KFactor= 15.59 37 36.14 2.157 0.0 8.000 20.404 K Factor = 8.00 to 120 0.0 0.0 0.0 38 36.14 0.0116 0.0 8.000 0.093 Vet = 3.17 38 36.22 2.157 iT 12.307 4.250 20.497 K Factor = 8.00 to 120 0.0 12.307 0.359 20 72.36 0.0420 0.0 16.557 0.696 Vel = 6.35 0.0 .72.36 21.552 KFactor= 15.59 35 35.95 2.157 0.0 8.000 20.190 K Factor =8.00 to 120 0.0 0.0 0.0 36 35.95 0.0115 0.0 8.000 0.092 Vel = 3.16 36 36.02 2.157 1 12.307 4.250 20.282 K Factor = 8.00 to 120 0.0 12.307 0.359 7 71.97 0.0416 0.0 16.557 0.688 Vet = 6.32 0.0 71.97 21.329 KFactor= 15.58 28 30.00 2.157 0.0 8.000 14.062 K Factor = 8.00 to 120 0.0 0.0 0.0 29 30.0 0.0082 0.0 8.000 0.066 Vet = 2.63 29 30.07 2.157 0.0 8.000 14.128 K Factor = 8.00 to 120 0.0 0.0 0.0 30 60.07 0.0298 0.0 8.000 0.238 Vel = 5.27 30 30.32 2.157 0.0 8.000 14.366 K Factor = 8.00 to 120 0.0 0.0 0.0 31 90.39 0.0634 0.0 8.000 0.507 Vet = 7.94 31 30.85 2.157 0.0 8.000 14.873 K Factor = 8.00 to 120 0.0 0.0 0.433 32 121.24 0.1090 0.0 8.000 0.872 Vel= 10.64 32 32.18 2.157 0.0 8.000 16.178 K Factor = 8.00 to 120 0.0 0.0 -0.433 33 153.42 0.1686 0.0 8.000 1.349 Vet = 13.47 33 33.08 2.157 iT 12.307 3.750 17.094 K Factor = 8.00 to 120 0.0 12.307 0.359 34 186.5 0.2418 0.0 16.057 3.883 Vel= 16.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Finai Calculations - Standard COSCO FIRE PROTECTION, INC. Page 6 Auto Dealership Date 122006 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 34 71.98 2.157 iT 12.307 0.830 21.336 to 120 0.0 12.307 0.0 9 258.48 0.4424 0.0 13.137 5.812 Vel = 22.69 0.0 258.48 27.148 K Factor = 49.61 21 30.07 2.157 0.0 8.000 14.132 K Factor =8.00 to 120 0.0 0.0 0.0 22 30.07 0.0082 0.0 8.000 0.066 Vel = 2.64 22 30.15 2.157 0.0 8.000 14.198 K Factor = 8.00 to 120 0.0 0.0 0.0 23 60.22 0.0299 0.0 8.000 0.239 Vel = 5.29 23 30.39 2.157 0.0 8.000 14.437 K Factor =8.00 to 120 0.0 0.0 0.0 24 90.61 0.0636 0.0 8.000 0.509 Vel = 7.96 24 30.93 2.157 0.0 8.000 14.946 K Factor = 8.00 to 120 0.0 0.0 0.0 25 121.54 0.1095 0.0 8.000 0.876 Vel = 10.67 25 31.82 2.157 0.0 8.000 15.822 K Factor =8.00 to 120 0.0 0.0 0.0 26 153.36 0.1684 0.0 8.000 1.347 Vel = 13.46 26 33.15 2.157 iT 12.307 3.750 17.169 K Factor =8.00 to 120 0.0 12.307 0.359 27 186.51 0.2420 0.0 16.057 3.885 Vel = 16.38 27 72.12 2.157 iT 12.307 0.830 21.413 to 120 0.0 12.307 0.0 10 258.63 0.4429 0.0 13.137 5.818 Vel = 22.71 0.0 258.63 27.231 K Factor = 49.56 14 30.18 2.157 0.0 8.000 14.227 K Factor = 8.00 to 120 0.0 0.0 0.0 15 30.18 0.0084 0.0 8.000 0.067 Vel = 2.65 15 30.24 2.157 0.0 8.000 14.294 K Factor = 8.00 to 120 0.0 0.0 0.0 16 60.42 0.0300 0.0 8.000 0.240 Vel = 5.30 16 30.50 2.157 0.0 8.000 14.534 K Factor = 8.00 to 120 0.0 0.0 0.0 17 90.92 0.0640 0.0 8.000 0.512 Vel = 7.98 17 31.03 2.157 0.0 8.000 15.046 K Factor = 8.00 to 120 0.0 0.0 0.0 18 121.95 0.1102 0.0 8.000 0.882 VeI= 10.71 18 31.93 2.157 0.0 8.000 15.928 K Factor = 8.00 to 120 0.0 0.0 0.0 19 153.88 0.1695 0.0 8.000 1.356 Vel = 13.51 19 33.26 2.157 iT 12.307 3.750 17.284 K Factor = 8.00 to 120 0.0 12.307 0.359 20 187.14 0.2434 0.0 16.057 3.909 Vel = 16.43 20 72.36 2.157 iT 12.307 0.830 21.552 to 120 0.0 12.307 0.0 ii 259.5 0.4455 0.0 13.137 5.853 Vel = 22.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • Final. Calculations - Standard COSCO FIRE PROTECTION, INC. Page 7 Auto Dealership Date 122006 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt P1/Ft Eqv. Ln. Total P1 Pn 0.0 259.50 27.405 K Factor = 49.57 1 30.01 2.157 0.0 8.000 14.074 K Factor = 8.00 to 120 0.0 0.0 0.0 2 30.01 0.0082 0.0 8.000 0.066 Vel = 2.63 2 30.08 2.157 0.0 8.000 14.140 K Factor = 8.00 to 120 0.0 0.0 0.0 3 60.09 0.0298 0.0 8.000 0.238 Vel = 5.28 3 30.34 2.157 0.0 8.000 14.378 K Factor = 8.00 to 120 0.0 0.0 0.0 4 90.43 0.0634 0.0 8.000 0.507 Vel = 7.94 4 30.87 2.157 0.0 8.000 14.885 K Factor = 8.00 to 120 0.0 0.0 0.0 5 121.3 0.1091 0.0 8.000 0.873 Vel = 10.65 5 31.75 2.157 0.0 8.000 15.758 K Factor = 8.00 to 120 0.0 0.0 0.0 6 153.05 0.1678 0.0 8.000 1.342 Vel = 13.44 6 33.08 2.157 IT 12.307 3.750 17.100 K Factor = 8.00 to 120 0.0 12.307 0.359 7 186.13 0.2410 0.0 16.057 3.870 Vel = 16.34 7 71.98 2.157 iT 12.307 0.830 21.329 to 120 0.0 12.307 0.0 8 258.11 0.4412 0.0 13.137 5.796 Vel = 22.66 8 0.0 6.357 0.0 10.000 27.125 to 120 0.0 0.0 0.0 9 258.11 0.0023 0.0 10.000 0.023 Vel = 2.61 9 258.48 6.357 0.0 10.000 27.148 to 120 0.0 0.0 0.0 10 516.59 0.0083 0.0 10.000 0.083 Vel = 5.22 10 258.63 6.357 0.0 10.000 27.231 to 120 0.0 0.0 0.0 11 775.22 0.0174 0.0 10.000 0.174 Vel = 7.84 11 259.50 6.357 2E 35.205 128.290 27.405 to 120 0.0 35.205 0.0 12 1034.72 0.0298 0.0 163.495 4.873 Vel = 10.46 12 0.0 6.357 1E 17.603 2.000 32.278 to 120 0.0 17.603 0.433 TOR 1034.72 0.0298 0.0 19.603 0.584 Vel = 10.46 TOR 0.0 6.357 2E 35.205 13.000 33.295 to 120 1 12.573 88.013 5.197 BOR 1034.72 0.0298 1S 40.235 101.013 3.010 Vel = 10.46 BOR 0.0 6.16 1E 20.084 13.000 41.502 to 140 0.0 20.084 0.0 DI 1034.72 0.0261 0.0 33.084 0.865 Vel = 11.14 Dl 0.0 6.09 2E 28.567 60.000 42.367 to 120 0.0 28.567 0.0 BFO 1034.72 0.0367 0.0 88.567 3.253 Vel = 11.40 BFO 0.0 6.16 3E 45.302 14.000 45.620 to 120 iZig 0.0 51.774 9.145 * Fixed loss = 9.145 BFI 1034.72 0.0347 2G 6.472 65.774 2.284 Vel = 11.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard COSCO FIRE PROTECTION, INC. Page 8 Auto Dealership - Date 122006 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BFI 500.00 6.09 0.0 20.000 57.049 Qa = 500 to 120 0.0 0.0 0.0 13 1534.72 0.0762 0.0 20.000 1.523 Vel = 16.90 0.0 1534.72 58.572 K Factor = 200.53 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 BE ON/ WIN M., COSCO Fire Protection Flow Test Static: psi Residual: '73 PSI Pitot: PSI Wft Flow: f ''C) GPM Date: I I / / Tested by:_ Location of hydrants (address or other) 6o(ô 4 Cross street f?iLai 4;rbi1 Provide accurate map and specify hydrant to flow (F) and hydrant to gauge (G) cIO WITNESSED BY: I4Ub((C ,d-1!Jti°0i