Loading...
HomeMy WebLinkAbout6860 AVENIDA ENCINAS; ; FA120007; PermitUlty ot uarlsbacl Fire Alarm Permit Permit No: FA120007 6860 AVENIDA Job Address: Status: APPROVED ENCINAS Permit Type: FALARM Applied 2/6/2012 Parcel No: 2144501900 Approved: 2/21/2012 Lot #: 0 Reference No.: Issued: 2/21/2012 PC #: Inspector: Project Title: KAISER PERMANENTE CSB PHARM. MOB PHARMACY TI Applicant: POWER COMMUNICATION SYSTEMS 4643-A MISSION GORGE PL SAN DIEGO, CA 619583-7400 Owner: KAISER FOUNDATION HEALTHPLAN INC 393 E WALNUT ST PASADENA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 279 0 279 0 I I I I I I I I I I I I I I I FAI2.0001- POWER COMMUNICATION SYSTEMS, INC. SALES - SERVICE - ENGINEERING I Public Address • Paging • Intercom • Fire Alarm • Nurse Call CCTV I, FILE COpy SUBMITTAL FIRE ALARM SYSTEM KAISER PERMANENTE CARLSBAD MOB PHARMACY T.I. 6860 AVENIDA ENCINAS CARLSBAD, CA 92008 P.O. Box 600066, San Diego, CA 92160-0066 • 4627-A Mission Gorge Place, San Diego, CA 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431-C7/C1O OWNER: KAISER PERMANENTE ELECTRICAL CONTRACTOR: CHULA VISTA ELECTRIC FIRE ALARM CONTRACTOR: POWER COMMUNICATION SYSTEMS, INC. I I I I I I I 1 I I I I I I I I I I I TABLE OF CONTENTS LIST OF MATERIAL . UL CERTIFICATE . NICET CERTIFICATE. . BUSINESS LICENSE CUT SHEETS 5000 MXL 2584 ZR-M C-CR, ZH-MC-CR 2585 MOUNTING APPLIANCES C.S.F.M. LISTINGS 7165-0067:0144 MXL 7125-0067:0252 ZR-MC-CR . 7125-0067:0248 ZH-MC-CR WARRANTY 1 2 3 4 5 6 7 11 LIST OF MATERIAL MODEL NO. MANUFACTURER DESCRIPTION QTY MXL SIEMENS FIRE SAFETY FIRE ALARM CONTROL PANEL EXISTING ZR-MC-CR U 14 STROBE - CEILING REMOVE & REINSTALL ZH-MC-CR HORN/STROBE - CEILING REMOVE & REINSTALL I I I I I I Underwriters Laboratories Inc. ® Northbrook, IL San Jose, CA Melville, NY Applicant ID No: 967165-001 Service Center No 0 Expires: 31-MAR-2012 A not-for-profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: SAN DIEGO, CA Alarm Service Company: (967165-001) Service Center: (967165-001) POWER COMMUNICATION SYSTEMS INC POWER COMMUNICATION SYSTEMS INC 4643-A MISSION GORGE PL 4643-A MISSION GORGE PL SAN DIEGO CA 92120 SAN DIEGO CA 92120 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S3669 -1 UUJS [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and Proprietary ***THIS CERTIFICATE EXPIRES ON 31-MAR-2012 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" I 0-kv, Fal ~Vtf 1111 0 2008 UL Form CS-CC NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES ® Providing Certification Programs Since 1961 BE IT KNOWN THAT Ernest.-Power, III IS HEREBY AWARDED CERTIFICATION AT LEVEL IV Y IN FIRE PROTECTION ENGINEERING TECHNOLOGY FIRE ALARM SYSTEMS BASED UPON SUCCESSFUL DEMONSTRATION OF REQUISITE KNOWLEDGE, EXPERIENCE AND WORK PERFORMANCE AS SET FORTH BY THIS INSTITUTE. Certification Valid through September 1, 2014 CERTIFICATION NUMBER 77846 H CHAIRMAN OF THE NICET BOARD OF GOVERNORS A DIVISION OF THE NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS — — — — — — — — — — — — — — — — — — — I FECI POWER COMMUNICATION SYSTEMS, INC. flSCR ... SALES—SERVICE— ENGINEERING I Public Address • Paging • Intercom • Fire Alarm Nurse Call • .CCTV I I I . State Of California .. CONTRACTORS STATE LICENSE BOARD i\ Consumer ACTIVE LICENSE I Affairs I . Lucenber 636431 Enhty CORP I nes POWER COMMUNICATION SYSTEMS INC . I •C5CS) 0-7 C 1 . I raonDe 01/31/2014 vvww.cslb.ca.gov &i I I . I I ,.. . I I P.O. Box 600066, San Diego, CA 92160-0066 • 4627-A Mission 'Gorge Pláe, San Diego, CA 92120-4133 (619) 583-7400 • Fax: (619) 583-0647' License Nb. '636431 -C7/CIO MXL Panel I I Catalog Sheet SIEMENS Fire Safety & Security Products I I MXL EXISTING Advanced Protection System ARCHITECT AND ENGINEER SPECIFICATIONS FirePrintTm application-specific detection More than 2,000 intelligent input-device capacity Multiple Command Stations Dynamic supervision of Intelligent Devices Security-device monitoring Sprinkler supervision Detector-sensitivity readout! printout, per NFPA 72 Chapter 7 Intelligent! Analog detection circuits: - Style 6 (Class A) or Style 4 (Class B) Conventional initiating circuits: - Style (Class A) or Style B (Class B) Notification appliance circuits: - Style Z (Class A) or Style Y (Class B) Degrade-mode operation Distributed processing 80-character backlit, alphanumeric display 32-character custom messages Thermal-strip printer Supervised remote printer Compare system software Fully field programmable, via laptop PC Menu-driven operator commands Central & distributed architecture Up to 800-event history log with online & off line reports User help screens Holiday schedule System Overview Logic-controlled output functions Multiple levels of password protection Automatic environmental compensation for smoke detectors One-person 'walk test' via 'loop,' 'zone' or 'system' Alarm verification by 'device' or 'zone' Time-base controlled output functions City Tie! Lease Line Coded outputs Supervised serial annunciator Driver! Input Interface 16-gauge steel enclosure Multi-language display Intelligent interface to building! process management systems Operates as an interactive peer with other MXL MXL-lQs or MXLV systems in a LifeLlNl( Network Pre-alarm operation NCC graphics Pre-action Releasing (NFPA 13) Halon & SinorixTM Approval (NFPA 12A& NFPA 2001) NEC 760 Power Limited Circuits (€UL 864 Compliant) UUKL Listed for Smoke Control *UL 864 91h Edition Listed, OULC Listed; CSFM, NYMEA, City of Chicago and U.S. Coast Guard Approved I I I I I [I I I I ' The MXL fire panel is a microprocessor-based advanced protection system. The use of the MXL system's unique multiprocessor 'Network' design; as well as its ability to utilize analog and conventional I detection devices, makes the MXL panel a highly flexible and reliable fire-control system. The MXL panel is ideally suited for commercial, institutional and industrial fire-detection and I notification applications. The MXL system complies with the requirements of NFPA Standard 72, and is listed by6Underwriters Laboratories (UL), I via their ®UL 864 9th Edition. tUnderwriter's' Laboratories of Canada (ULC) also lists the MXL panel for fire applications. The MXL system is I I SIEMENS Industry, Inc. Building Technologies Division approved by CSFM, the City of Chicago and NYMEA for use in those specific locales. In addition to the standard fire applications, MXL is also listed by ®UL - under the category 'UUKL for Smoke Control.' The MXL panel can be used as a listed fireman's smoke- control station in high-rise office buildings, malls and other multi-level or vast structures. The MXL system also complies with Uniform Building Code Section 905 requirements for smoke control. MXL is approved by the US Coast Guard for marine applications such as ships and oil drilling platforms. The MXL panel is listed by ®UL for releasing Halon 1301, SinorixTM Engineered Fire Suppression System and MXL 5000 System Overview -(continued) pre-action or deluge sprinkler systems. These include foam or water applications. MXL follows the releasing requirements specified in the NFPA Standards 12A, 13 and 2001. MXL Components The basic MXL control unit consists of the following sub-assemblies: MMB-3 Main Control Board; MPS-6 I MPS-1 2 Power Supply; MKB-2 Annunciator and Keyboard; MME-3, MLE-6 or MSE-2 Enclosures. Optional modules—which can be installed with the MXL System - include: MOM-2/4 Expansion Card Cage; ALD-21 Analog Loop Driver; CRM-4 Controllable Relay Module; NIM-1W Network/Foreign Systems Interface Module; REP-1 Network Repeater Module; XLD-1 "X" Series Loop Driver; CSM-4 Controllable Signal Module; CZM-4 Conventional Zone Module; PlM-i Peripheral Interface Driver; CMI-300 CXL Modem Interface Module; PSR-i Remote Power Supply; MXL-VDT Interactive Video Display Terminal; NET-4 Style 4 Network Interface; NET-7 Style 7 Network Interface. Additionally, the MXL system includes option modules MOI-7 System Interface, MOD-16 Output Driven and MID-1 6 Point Input Module. These option modules can be used to drive graphic annunciators and Fireman's Smoke Control Stations, or to monitor foreign systems. The MXL is compatible with a full line of intelligent initiating devices highlighted by the FirePrintlM application-specific detectors: Models FP-1 1 and FPT- 11. The MXL panel is also compatible with FireFinder, the NCC series of text and graphic command centers. MXL Enhanced Main Board (MMB-3) MMB-3 The function control of the MXL is contained on the MMB-3 Main Control Board. Model MMB-3 offers a fast, integral microprocessor and installation conveniences such as diagnostic LEDs and removable terminal blocks for field wiring. Model MMB-3 acts as the central controller for the system, and includes two (2) ALD circuits and two (2) notification appliance circuits. Model MMB-3 mounts in the MXL enclosure backbox. SIEMENS Industry, Inc. Building Technologies Division Display I Keyboard (MKB-2) MKB-2 The MKB-2 display I keyboard mounts on a hinged frame in the MXLV enclosure, and provides: Two-line, 80- character LCD display indicator LEDs display-control keys numeric keypad user-programmable function keys all other keys necessary for operator control These keys include but are not limited to: Acknowledge; Silence and Reset. Model MKB-2 also includes spaces for mounting the Model MMM-i microphone module and the Model TMM-1 telephone. Model MKB-2 is supplied with two (2) blank plates for use when either the microphone or telephone is omitted. Display I Keyboard (MKB-5) MKB-5 The MKB-5 display / keyboard mounts on the inner door of any MXL enclosure backbox and provides: 6-1/4" VGA backlit, 80- character LCD display indicator LEDs 12 programmable function keys numeric keypad user-programmable function keys all other keys necessary for operator control These keys include but are not limited to: Alarm; Supervisory; Trouble and Security. Multiple MKB-5s can be used in the system, each providing full control of the MXL system. Up to four (4) Model MKB-5 can operate in a fully supervised mode; each with independent printer driver capability built-in. Power Supply (MPS-6) I MPS-6 MXL Components - (continued) Model MPS-6 is a fully supervised power supply that provides the MXL system with primary DC power. Model MPS-6 is rated at 6.5 Amps, and is unfiltered and unregulated. Model MPS-6 supplies power to the MXL Control Unit, and supplies its expansion modules with power required for normal operation. Model MPS-6 incorporates a circuit breaker on the primary input, and includes a built-in AC-line filter for surge and noise suppression. Model MPS-6 mounts in the MXL enclosure backbox. Power Supply (MPS-12) MPS-12 Model MPS-1 2 is a fully supervised power supply that provides the system with preliminary DC power. Model MPS-12 is rated at 12 Amps, and is unfiltered and unregulated. Model MPS-12 supplies power to Models PSR-1, MMB-2 and their expansion modules with power required for normal operation. Model MPS-1 2 incorporates a resettable circuit breaker on the primary input, and includes a built-in AC-line filter for surge and noise suppression. Model MPS-12 mounts in the MXL enclosure backbox. Network Optional Module Card Cage (MOM-4) MOM-4 The Model MOM-4 Card Cage provides the MXL main unit or remote units with card slots for option modules. Each Model MOM-4 supplies connection space for either two (2) full-width option modules: (Models ALD-21, CZM-4, NIM-1 R, XLD-1) or four (4) half-width option modules: (Models CSM-4, CRM-4, CMI-300, NET-7, REP-1) or a combination of one (1) full and two )2) half-width modules. SIEMENS Industry, Inc. Building Technologies Division Network Optional Module Card Cage (MOM-2) MOM-2 Model MOM-2 provides the MXL main unit, remote units or MXL small enclosures (Model MSE-2) with card slots for optional modules. Each Model MOM-2 provides space for one (1) full-width module (Models: ALD-21, CZM-4, and NIM-i R) or two (2) half-width optional modules (Models: CSM-4, CRM-4, CMI-300, NET-7, REP-1). Analog Loop Driver (ALD-21) ALD-21 Model ALD-21 is a MXL network-option module that supplies two (2) intelligent analog circuits utilizing Fire Safety "1", "IL", and FP series intelligent devices. Model ALD-21 occupies two (2) addresses on the MXL Network and through the use of unique communication-protocol devices connected to the circuits of Model ALD-21. The circuits are dynamically supervised by the MXL control panel. Up to 60 programmable input and output devices may be connected to each of its two (2) circuits. Each circuit may be wired as Class B (Style 4) or Class A (Style 6). Controllable Signal Module (CSM-4) CSM-4 Model CSM-4 provides two (2) fully supervised, programmable notification-appliance circuits. Model CSM-4 supplies two (2) Class B (Style Y) or Class A (Style Z)-type output circuits for the supervision and control of listed audible or visual notification appliances such as: horns, bells, strobes, etc. Each circuit can provide up to 1.5 amps (24 VDC) of current to power notification appliances. Model CSM-4 is also used for suppression-agent releasing (SinorixTM, Halon, Pre-Action Sprinkler and Deluge) systems. Leased line and municipal-tie connections are also possible with Model CSM-4. MXL Components - (continued) Controllable Relay Module (CRM-4) CRM-4 Model CRM-4 is designed to provide auxiliary control of building functions such as: door- holder release, elevator capture, smoke control, lock release, etc. Model CRM-4 provides four (4) fully programmable relays. Each relay contains one (1) set of SPDT contacts rated at 2 amps 30 VDC /120 VAC resistive. Communication Module (NET-4) NET-4 Model NET-4 is a plug-in-type module used to provide communication between the Fire Safety MXL panel and various other MXL remote modules. Model NET-4 is designed to plug into an edge-connector-type slot on the Model PSR-i Network Supply. Model NET-4 provides NFPA Style 4-type communication: fully digital; RS-485 operating at 19.2K Baud rate. Style 7 Network Interface Card (NET-7) NET-7 Model NET-7 is a microprocessor-controlled MXL network-interface module that allows the wiring of the MXL RS-485 network in a NFPA Style 7 configuration. Model NET-7 plugs into a half slot of the Models MOM-2/4 card cage at the MXL command center (MMB-2) and at the Model PSR-i or Model MOM-4 slot at the MXL remote units (MXLR, MXLRV). SIEMENS Industry, Inc. Building Technologies Division Model NET-7 provides two (2) independent and fully supervised communication paths, allowing system operation through an open and short circuit. Model NET-7 also isolates the power supplies at each remote unit, providing the ability to localize ground-fault conditions. The communication for Model NET-7 operates at 19.2K Baud rate and is fully digital. Network Repeater Module (REP-1) REM Model REP-1 provides the ability to configure the local or global networks of the MXL panel in a 'star' or 'daisy-chain' configuration. Model REP-1 provides two (2) Style 4 or one.(i) Style 7 RS-485 network circuits. Through the use of Model REP-1, the MXL's local network (MXL-MXLR) can be expanded up to 64 nodes. Remote Power Supply (PSR-I) PSR-1 Model PSR-i is a microprocessor-controlled remote power supply and battery charger for use with the MXL panel. Model PSR-i operates in conjunction with either a Model MPS-6 or MPS-1 2, providing 6 or 12 Amps of power for use with various MXL modules. When used with a Model NET-4 or Model NET-7 plug-in communication module, Model PSR-i becomes a part of the MXL panel's internal network. Model PSR-i acts as an interface between remote-option modules and the MXL. I I MXL Components - (continued) Output Driver (MOD-16) Peripheral Interface Driver (PIM-1) PIM-1 Model PIM-i is a MXL option module that provides a bidirectional, isolated RS-232 port for connection to peripheral devices, such as: printers, CRTs, VDTs, color graphics, alphanumeric pagers and remote diagnostics hardware. Model PIM-i mounts in the MXL enclosure, and connects to Model MMB-3, providing a screw-terminal block for connection of RS-232. A number of supervised and non-supervised formats are available for Model PIM-1. Output I Input Module (MOI-7) MOI-7 Model M0I-7 is a MXL RS-485 network module that provides a fully programmable serial interface to Model MOD-1 6 output drivers and MID-1 6 input drivers. When used with Model MOD-16 drivers, Model M0I-7 provides a serial-annunciator output or relay driver. When used with Model MID-1 6, Model M0I-7 provides programmable inputs. Each Model M0I-7 can operate up to eight (8) Model MOD-16 drivers and eight (8) Model MID-16 drivers simultaneously. Each Model MOD-1 6 output and Model MID-1 6 input is independently programmable, via the MXL custom software. MOD-16 Model MOD-1 6 is an output-driver module used in conjunction with Model M0I-7, as a part of the Fire Safety MXL System. Up to eight (8) Model MOD-1 6s can be connected to a Model M01-7 interface module. Each Model MOD-16 provides 16 open-collector, current-sinking outputs, which are rated at 24 VDC, 50mA. Model MOD-i6 outputs are programmable, via the MXL custom software. Programmable Input Driver (MID-16) MID-16 Model MID-1 6 is an input module used in conjunction with Model M0I-7, as a part of the Fire Safety MXL System. Up to eight (8) Model MID-1 6s can be connected to a single Model M0I-7, along with eight (8) Model MOD-1 6 output-driver modules. Each Model MID-16 provides a non-supervised input, which can monitor normally open contact devices. Each Model MID-1 6 input can be separately used as a part of the MXL custom programming logic. These inputs can be individually set for: Alarm, Supervisory, Trouble, Security or Status usage. Further, the Model MID-16 inputs can also be configured to provide supervision for lamps driven by Model MOD-1 6 outputs. Screw terminals and connectors are provided on the Model MlD-16 modules for interface to monitored devices. MXL /(V) Standard Size Enclosure (MME-3) I I I I I [I I I I I I 1 I I I I I MME-3 SIEMENS Industry, Inc. Building Technologies Division MXL Components - (continued) The Model MME-3 enclosure set consists of a sheet- metal back box and door with key-lock. Model MME-3 can be used for the MXL System, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (via the Model MSR-1 Rail Kit). To mount MXL I MXLV modules in Model MME-3, the Model MBR-MP removable-module mounting plate is required. Using the Model MBR-MP mounting plate - one (1) Model MMB, or one (1) Model PSR-1, and up to three (3) expansion cardcages (Model MOM or Model 0MM) can be mounted in the Model MME-3 enclosure. When used to mount MXL amplifiers (Model EL-410), the Model MBR-MP module is not required. Instead, up to three (3) Model EL-410 amplifiers may be installed in Model MME-3, via three (3) Model MSR-1 Rail Kits. When amplifiers are mounted in any enclosure, always install Model MDG-1 grills in the door for proper ventilation. Model MME-3 is designed for surface of semi-flush mounting, and includes various knockouts for wire and conduit entry. The door in the Model MME-3 set has two (2) cutouts for clear lenses, blank plates or grills - depending on the application - and contains a key-lock. MXL MME-3 and MLE-6 Modules Mounting Plates (MBR-MP) MBR-MP The Model MBR-MP MXL IV Module Mounting Plate is required for use in both Models MME-3 and MLE-6 enclosures in order to mount all MXL and MXLV equipment. Model MBR-MP is not necessary if the Models MME-3 and MLE-6 enclosures are to be used only for mounting of amplifiers (EL-41 0). Model MBR-MP is a removable MXL IV module mounting plate that allows the Model MME-3 or Model MLE-6 enclosure to be shipped to the job site for wiring and conduit installation, while the system hardware (electronics) is mounted to the studs on Model MBR-MP - pre-wired, programmed and tested - prior to delivery and installation at the job site. This process allows for faster, more efficient system start-ups with less chance of the sensitive electronics being damaged while field wiring and conduit are connected to the system enclosure. SIEMENS Industry, Inc. Building Technologies Division The Model MBR-MP mounting plate bolts to the Model MME-3 or Model MLE-6 enclosures for easy installation on the job site. Model MBR-MP also has handles to allow easy transport and mounting. The MBR-MP contains mounting studs for one (1) Model MMB or Model PSR-1; one (1) Model PIM-1; one (1) Model TBM-2, and up to three (3) Model MOM or Model 0MM card cages or two (2) cardcages and one (1) TSP-40 Printer (same mounting studs as the Model MBR-2 enclosures). Model MBR-MP is ordered and shipped separately from the Models MME-3 and MLE-6 enclosures. MXL /(V) Large Size Enclosure (MLE-6) MII-6 The Model MLE-6 enclosure set consists of a sheet-metal back box and door with two (2) key-locks. Model MLE-6 can be used for the MXL system, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (via the Model MSR-1 Rail Kit.) To mount MXUV modules in Model MLE-6, the Model MBR-MP removable module mounting plate is required with the Model MBR-3MP option available for use. Using the Model MBR-MP mounting plate, one (1) Model MMB or Model PSR-1 and up to three (3) expansion cardcages (Model MOM or Model 0MM) can be mounted in Model MLE-6. If additional card cages are required, the Model MBR-3MP optional card cage mounting plate can also be installed in Model MLE-6 - below the MBR- MP. Model MBR-3MP allows mounting of an additional three (3) Model MOM or Model 0MM module expansion cardcages. Various combinations of hardware can be installed in Model MLE-6. If only amplifiers are to be installed in Model MLE-6, no Model MBR-MP or Model MBR-3MP plates are required. Instead, up to five (5) Model EL-410 amplifiers can be installed by using five (5) Model MSR-1 rail kits. The Model MLE-6 can also be used to mount up to three (3) MXL cardcages and two (2) amplifiers. This configuration would be typical of a remote, voice transponder cabinet. In this configuration, one (1) Model MBR-MP would be used in the upper half of Model MLE-6 to mount the MXL modules, while the lower half would use two (2) Model MSR-1 rail kits to mount up to two (2) Model EL-41 0 amplifiers. MXL Components - (continued) Model MLE-6 is designed for surface or semi-flush Mounting, and includes various knockouts for wire and conduit entry. The door supplied with the Model MLE-6 set has three (3) cutouts for either clear lenses, blank plates or grills - depending on the application. The door also contains twp (2) key-locks, which are keyed the same. Various combinations of dead-front mounting plates are possible with the Model MLE-6 enclosure A typical MXLV installation would have one (1) Model MKB-2 at the top, and two (2) Model MHD-3 dead- front plates in the middle [for 14 VSM I VLM I VFM modules per plate] and one (1) or two (2) Model MHD-2 lower dead-front plates. MLE-6 Optional Cardcage Mounting Plate (MBR-3MP) Upper or Middle Dead-Front Panel (MHD-1) MHD-1 Model MHD-1 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the upper or the middle section of the Model MME-3 backbox, or the upper or either of the two (2) middle sections of the Model MLE-6 backbox. Model MHD-1 has an opening with a cover plate for the Model TSP-40 printer (when used), and attaches to the backboxes with screw fasteners. Once in place, Model MHD-1 covers and protects modules and wiring; providing dead-front construction to that area. Lower Dead-Front Panel (MHD-2) MBR-3MP Model MBR-3MP is an optional MXL I MXLV card cage mounting plate for use exclusively in the Model MLE-6 enclosure. When installed in the Model MLE-6 backbox, Model MBR-3MP adds the option of mounting up to an additional three (3) Model MOM or Model 0MM expansion card cages. Clear Lens (MDL) MDL Model MDL is a clear Plexiglas® lens that fits in one (1) of the two (2) openings in the Model MME-3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One (1) lens is included in the Model MDL-1 package. Sheet Metal Blank Plate (MDB-1) MDB-1 Model MDB-1 is a sheet-metal blank plate that fits in one (1) of the two (2) openings in the Model MME-3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One (1) blank plate is in the Model MDB-1 package. SIEMENS Industry, Inc. Building Technologies Division MHD-2 Model MHD-2 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the lower section of the Model MME-3, and on the lower two (2) sections of the Model MLE-6 backbox. Model MHD-2 has no openings and attaches to the backboxes with screw fasteners. Once in place, Model MHD-2 covers and protects modules and wiring; providing dead-front construction to that area. Middle Dead-Front Plate for Mounting Switch and LED I Fan-Control Modules (MHD-3) I - ___ j MHD-3 Model MHD-3 is a hinged sheet-metal panel that attaches to the Model MME-3 or MLE-6 enclosure backbox, and fits in either the middle of the upper sections of the Model MME-3 or MLE-6 enclosures. Model MHD-3 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Model MHD-3 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Each row can mount up to seven (7) modules, totaling 14 modules for each Model MHD-3. Model MHD-3 attaches to the backboxes with screw fasteners, and is hinged for easy access to the rear of the modules inside the enclosure. MXL Components - (continued) Middle Dead Front Plate for the Switch/LED! Fan-Control Modules with Printer Cutout (MHD-4) EC. MHD-4 Model MHD-4 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the middle section of both enclosures. Model MHD-4 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Each row has space to mount four (4) modules, totaling eight (8) modules for each Model M H D-4. Model MHD-4 also has a cutout to display the Model TSP-40 Internal Thermal Strip Printer. Model MHD-4 mounts to the backboxes with screw fasteners, and is hinged for easy access to the rear of the modules and inside of the enclosure. When in place, Model MHD-4 covers and protects modules and wiring, providing dead-front construction to that area. When the Model MLE-6 enclosure is used with the Model MBR-MP mounting plate for installation of MXL or MXLV equipment, up to two (2) Model MSR-1 Rail Kit rows can also be installed in Model MLE-6 for mounting of either two (2) Model EL-41 0 amplifiers or some complement of System 3-type mount modules. MPS-12 transformer/ supply, can accept NET-4 or NET-7 network interfaces, and includes diagnostic LEDs and two (2) system relays. Model PSR-1 mounts in the upper section of the MXL enclosure backbox. MXL Small Enclosure (MSE-2) MSE-2 Model MSE-2 is a small MXL enclosure capable of housing an MMB-2 or PSR-1 and MPS-6 or MPS-1 2. When expansion is required the MSE-2 provides for mounting of either one (1) MOM-2 or OMM-2. MSE-2 is part of the MXL-SS and MXLV-SS packages. Thermal Strip Printer (TSP-40A) Rail Kit (MSR-1) no MSR-1 TSP-40A Model MSR-1 is a System 3TMtype rail kit that fits into either the Model MME-3 or MLE-6 enclosure backbox. Model MSR-1, which comes with a U-bracket and a Z-bracket, allows the following modules -or any other System 3-type module -to be mounted in the Model MME-3 or Model MLE-6 enclosure: Model EL-410 amplifier Model P5-35 power supply Model BC-35 battery charger Model M0I-7 I/O interface Model MID-1 6 input driver Model MOD-1 6 output driver Model PS-5A power supply Model SYS3-MPFO [for mounting the D2300CP fiber-optic interface modules, or the ccu pager interface] When used in the Model MME-3 enclosure three (3) Model MSR-1 Rail Kits can be installed to mount up to three (3) rows for up to three (3) EL-41 0 amplifiers. When used in the Model MLE-6, up to five (5) MSR-1 Rail Kit rows can be installed to allow mounting for up to five (5) EL-410 amplifiers. SIEMENS Industry, Inc. Building Technologies Division Model TSP-40A is a thermal strip printer, designed as an event-logging device for the MXL panel, providing a permanent-history report of all system activity. Model TSP-40A mounts in the MXL enclosure, and its printout is visible through a window in the locked-door enclosure. Printouts are automatically spooled on a take-up reel for easy records storage. Remote Command Console (RCC-1) RCC-1 Model RCC-1 is a remotely located MXL annunciator display module. Model RCC-1 contains an 80-character LCD display and control keypad (MKB), as well as a PS-51\17 network interface. MXL Components - (continued) Model RCC-i modules can be located anywhere that annunciation or control is required. Model RCC-i can be programmed for display only, or can provide display and system control. Remote printers, VDT, or graphics computers can be located throughout a facility - if Model PIM-i is added to Model RCC-1. ®UL Listed Parallel Printer (PAL-11) PAL-1 Model PAL-1 is a tUL Listed, supervised parallel-system printer for the MXL panel. Model PAL-1 connects to Model MKB-5 to provide the MXL panel with a ®UL Listed, supervised parallel-system printer. 66 Intelligent Control Point (ICP) lcP Model ICP is a field-mounted output module that is capable of being programmed to either a remote bell or horn - or to a speaker or telephone zone. Model ICP communicates with the MXL fire panel, via ALD loop. Line-Isolator Module (LIM-I) LIM-i Model LIM-i is a short-circuit isolator module for use on the analog loops of the MXL panel. Model LIM-i is capable of providing Style 4 or Style 6 wiring of the ALD loop. Multiple short-circuit isolators can be used on a single ALD loop to prevent loss of protection in the event of a short circuit. 5-Volt Power Supply / Network Interface (PS-5N7) Model PS-5N7 is a 5V power supply and MXL local-network interface module. Model PS-51\17 is an integral part of Model RCC-1. Model PS-51\17 can be used to provide a Style 4 or Style 7 network interface for either a remote transponder for the MXLV panel (with either Model TBM-2, ACM-1 and VSM-1 I VLM-i I VFM-1), or to drive Model 0MM-1 and associated MXLV cards. 5-Volt Power Supply (PS-5A) Model PS-5A provides 5 Volts for powering Model M0I-7. Model PS-5A obtains its power from the 24-Volt power supply in the MXL system. Models M0I-7 and PS-5A both mount on System 3 rails, and can also be mounted externally to the MXL system. Models M0I-7 and PS-5A typically drive remote-graphics annunciators or monitor foreign systems and devices. Network Interface Module (NIM-11W) MM-1W Model NIM-iW allows for the interconnection or networking of up to 63 MXL panels. Model NIM-1W provides a RS-485 communications path in either Style 4 or Style 7 wiring configurations. Model NIM-iW allows MXL panels to have inter-panel logic, as well as communicate in a peer-to-peer manner. Model NIM-iW can be programmed via CSGM logic as a Foreign System Interface to communicate with external-building management systems. SIEMENS Industry, Inc. Building Technologies Division I I I I I I I I I U I I I I I I I I I Details for Ordering Model Number Siemens Installation- Sheet Number Description CZM-1 315-090725 Conventional Zone Module ILl-i /1 H I 1AI 1AH 315-092724 Intelligent Ion Detectors ILP-1 I IPLT-1 315-092594 Intelligent Photo Detectors ILl-i 315-093336 Intelligent Heat Detectors ILl-lB I 1 B 315-093234 Intelligent Ion High Velocity Detectors I LP-2 315-095028 FirePrintTM Application-Specific Detection MSI-10BI 20B 315-093329 Intelligent Manual Station MS-MI 315-092169 Intelligent Metal Manual Station TRI-136 I 136D I 13611 315-093315 Intelligent Monitor Module [single / dual with array] TRl-136M 315-094547 Intelligent Mini-Monitoring Module ICP 315-092471 Intelligent Control Point UM-i 315-092135 Line-Isolator Module FP-1 1 315-095921 Intelligent FirePrintTM Detector TRI-S/DIR 315-096242 Intelligent Monitor Module Note: For further details, refer to MXL IOM manual: 315-092036. Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario March 2010 Building Technologies Division Tel: (973) 593-2600 SIll L6T 5E4 / Canada Supersedes sheet dated 1/06 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 Re,. I) URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 (ZR8 Mountin SIEMENS Catalog Sheet Fire SafetyESecurity Products '08 Series Notification Appliances ZH & ZR - Strobes, Horns, & Horn / Strobes Application: Indoor - 4 ' 'F. ZH Series ZR Series I Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, I XLS panel, or PAD-3 power supply with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (ZH) - Ceiling-mount models feature field-selectable Candela settings of 1 5130/75/95cd and 115/177cd - Wall-mount models feature field-selectable Candela settings of 15130/75/ll0cd and 1351185cd I - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce 1 flash per second I - "Special Applications" listed with Siemens panels - EZ Mount Universal Mounting Plate (ZBB) - uses single plate for ceiling and wall mount installations - EZ Mount design - with separate base plate - provides ability to pre-wire the base - and test the circuit wiring before the walls are covered I - ®UL Listed & ®U LC Listed; FM, CSFM & NYMEA Approved - ADA! NFPA compliant I Specifications General 1 - Audible/Visual notification appliances shall be listed for indoor use only - Appliances shall be listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) I - Appliances shall use a universal back plate, which shall allow, mounting to a single-gang, double-gang, 4-inch-square, 4"-octal, or a 3-112"-octal backbox - Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate I - Continuity check shall occur for entire NAC circuit prior to attaching any audible I visual-notification appliances - Dust cover shall fit and protect the mounting plate - Dust cover shall be easily removed when the appliance is installed over the back plate I - Removal of an appliance shall result in a trouble condition by the Fire Alarm Control Panel (FACP) 1 I 108 Series Notification Appliances 2584 I SIEMENS Industry, Inc. Building Technologies Division I I I I k I Specifications - (continued) Strobes - Strobe appliances shalt produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens - Strobes shalt be available with two or four field-selectable settings in one unit, and shall be rated - per €UL 1971 - for up to: 1513017511 10cd for wall mounted 135I185cd for wall mounted 1 5130175195cd for ceiling mounted 11 5/1 77cd for ceiling mounted - Strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 490C), and be listed for maximum humidity of 95% RH - Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) Audibles and Audible! Strobe Combinations - Horns and horn I strobes shall be listed for Indoor use under UL Standard 464 - Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output - Horns shall have at least 2 sound-level settings of 90 and 95 dBA Synchronization Modules - The strobe portion, when synchronization is required, shall be compatible with DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol - The strobes shall not drift out of synchronization at any time during operation - Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability to silence the audible, if required - Strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. - contacts remain closed) - All notification appliances shall be listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" )' Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1 -to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on @UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) Series ZH horns are listed under ®IJL Standard 464 for audible signal appliances (Indoor use only) SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram (Shown In Inches) Mounting Options 07T ONAL. SECURING FIAT SCREWDRIVER Fierek Ir.sThLc:ion Fiee4: aenoval(see jtD 8 Wow) 1., Instal mountg pate as shovm in figure 1 to a single-gang, Pi. lmper'.ant Device cny has one rxrcwslrng orientatas. ?.laith the double-gang. 4 square. 4 octagcn, or a 3 W octagon bacthcx top of the base to the top of the device. with the provided pan head screws. To remove dust cover, 7. If it is desired to further secure the devrce to the base, then two place thumb and index finger on top edges of cover and pull oft optional screws are provided. To install these screws punch cut cover, the screv, holes located at the top and bottom of the de/ce. Connect field wiring per figures 2 and 3. & To remove the appliance, push a small fat-blaced screwdriver Address verse back into backbox into the side opening. The screwdgver must clear the snap Place dust cover over mounting pate to protect the terminats release opening by/.' to disengage the snap. Do not pry off white performing wiring continuity theck. housing with the screw driver. Apply pressure with sew driver. Remove dust cover before snapping or installing the appliance inserted in either side opening, as shown in Fig 4 to reea3e the onto the mounting pale per fig 3. housing. Technical Data ZH and ZH.MC Horn Reverberant d8A Per ®UL464 ZH Horn Current Draw CZH-MC and ZH at 24V] (Ai1ps) 16-33 Volts Setting 16.OV 24V 33.OV High' 1 0.044 IContinuous II High 83 87 90 1 DC Low' 1 0.018 I Horn II Low 77 81 83 I FWR High' 0.075 I Code 3 Horn or H High 79 82 86 I LOw' 0.045 I March Time' H Low 12 76 19 *Ourrent Cvea is the same for the Continuous Horn, Code 3 Horn and March Time settings. 'Available in sync mode only SIEMENS Industry, Inc. Building Technologies Division Technical Data - (continued) Models' ®UL Listed Models and Ratings Operating voltage (Special Application) [Per ®tJL1971] (VDC/VRMS) voltage Range [per@UlC S526-02] (VDCNRMS) Horn Mounting Strobe Candela (c) ZR-MC 16.0-33.0 20.0-31.0 - Wall 15/30175/110 ZR-HMC 16.0-33.0 20.0-31.0 - Wall 1351185 ZR-MC-C 16.0-33.0 20.0-31.0 - Ceiling 15/30/75195 ZR-HMG-C 16.0-33.0 20.0-31.0 - Ceiling 115/177 ZH-MC 16.0-33.0 20.0-31.0 X Wall 15130/75/110 ZH-HMC 16.0-33.0 20.0-31.0 X Wall 135/185 ZH-MC-C 16.0-33.0 20.0-31.0 X Ceiling 15/30/75/95 ZH-HMC-G 16.0-33.0 20.0-31.0 X Ceiling 115/177 ZH 16.0-33.0 20.0-31.0 X Wall or Ceiling - - 'AvaiLable in red and white DC 16-33VDC FM 16-33VRMS ®UL Current Ratings (ZRStrobe Only) Maximum RMS Current (AMPS) MC HMC ( MC-C I HMC-C 15cd 30cd T5cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd ll5cd 177cd 0.064 0.098 0.175 0233 0.318 0.445 0.069 0111 0200 0.264 0.318 0.445 0.108 0.164 0.268 0.368 0482 0.684 0.117 0.180 0.297 0.398 0.482 0.684 ®UL Current Ratingi ZH Horn/Strobe Maximum RMS Current (AMPS) Horn Setting MC HMC (MC-C HMC-C 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95 c 115cd 177cd DC 16-33VDC High' 0.078 0.113 0.195 0.259 0.371 0.506 0.087 0.131 0.222 0.292 0.371 0.506 Low' 0.070 0107 0188 0.246 0.324 0.455 0.075 0.121 0.213 0.277 0.324 0.455 16-33VRM.., High' 0.141 0.200 0.302 0.406 0.521 0122 0.149 0.216 0.331 0.436 0.521 0.722 Low' 0.123 0.179 0.290 0.391 0.497 0.699 0.131 0.195 0.319 0.421 0.497 0.699 'Current VU3WIS tfle same tor the continuous mom; Code 3 Horn and March Time Settings Details for Ordering - (Including Mounting Options & Agency Approvals) Aciencv Approvals Model Number Part Number Description Mounting Options' UL - ULC - FM - CSFM - ZH-R 500-636159 Z Horn: Red B,D,E,F X X X X ZH-W 500-636160 Z Horn: White B,D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F X X X X ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F X X X X ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F X X X X ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela (Wall), White B,D,E,F X X X X rzH-MC-cR' 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F X X X X ZH-MC-CW 500-636166 Z Horn: Multi Candela (Ceiling), White B,D,E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F X X X X ZH-HMC.CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F X X X X ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F X X X X ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall), White B,D,E,F X X X X ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B,D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B,D,E,F X X X X ZR-MC-CR'. 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E,F X X X X ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red B,D,E,F X X X X ZRS-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White B,D,E,F X X X X ZBB-R 500-636193 Accessory - (Includes base, dust cover, mounting screws and installation sheet) ZBB-W 500-636194 Accessory - (lncludes base, dust cover, mounting screws and installation sheet) X = listed! approved * = Refer to catalog sheet 4: 2585 for detailed mounting options Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard çlIARIç ir,r1,ac1r, in, Plnrh,n, P,rt, NJ 07932 Rrimntnn Ontario Building Technologies Division let (973) 593-2600 15111 L6T 5E4 Canada December 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905)7999937 Sope,edesheetd,td 7/07 URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 I I I I I I I Catalog Sheet SIEMENS Fire Safety & Security Products '08 Series Notification Appliances Mounting Options Mounting Diagrams I Mounting Matrixes I Mounting Notes ARCHITECT AND ENGINEER SPECIFICATIONS (A) UNIVERSAL MOUNTING PLATE 4" SQUARE, DEEP, FLUSH (80) (I) WPBBS - ORDER CODE— RED: 500-636137 Q o o () Plastic backbox for surface movnng AS series weatherproof, outdoor products. : i-- __________ 2-13132" 0 LO _ ASMounsg 155,5 SIts AS seSes s4:es 5-VIC" Used wAh Series Used with Series AM., AS Used with Series AH,AS,66.810,HS,MBDC,MH1I5,HTH. AS (leetherprooi) (B) SINGLE-GANG, FLUSH (BO) (C.) SINGLE-GANG, SURFACE (BO) (J) BBS BACKBOX NH, i4S,SETSF. SETULC,ST.ZH,ZR ORDER CODE— RED: 500-636110 Standard steel backbox with knockouts DOUBLE-GANG, FLUSH (B77 for interior surface mounting, ooncea'ed conduftnountgorsemi-tiush - appcab,ns. Deep PROIMED,r-i ?NOCKO'JTL? FOR Y, &5 co'-,,Urs. - Used with Senes Used with Seres , Used with Seces Used with Series AM. AS.66, Blg,MBDc. AH,AS. MH, NH, MS. SE 2H,2R MM AM, AS, MS. HIM, NftST, ZH,ZR MHII&MTH-15-115, NH, ST (D) 4' SQUARE, FLUSH (BO) DOUBLE-GANG, SURFACE (80) (K) WBBS WEATHER RESISTANT BACKBOX ORDER CODES- RED: 500-636129 WHITE: 500-636131 0 Sfarfy die cast housing, threaded conduit hole and and knockout for outdoor appltcations Ov4 1-1% Deep I 34 Used with Series . AH, AS. B6,BlO,HS,MBOC,HH1l, NIH Used with Series Used withSeries NH, NS.SEISF. SET-UIC,.ST,ZH,ZR AM, AS, NH, MS. ST AH,B6,61,MBDC.1.11-111, 10TH-15-11, SETSF '08 Series Notification Appliances 2585 SIEMENS Industry, Inc. I Building Technologies Division I I I I I I I I I I I I I I I] I I I (1) ISPS2 SURFACE ADAPTER (P.) SBBS BACKBOX (T) WPSBBS ORDER CODES- WHITE: 500-636195 ORDER CODES— RED: 500-636119, ORDER CODES— RED: 500-636139, RED: 500-636196 WHITE: 500-636120 WHITE: 500-636140 5-114 ..0 For surface mounting speakers, chimes, and electronic applications. k2 4 iJ:413s - rw i 10400XCLITO KNOCXCUTS - 1-3116 4-5132" MACH SicEt (EACH SIDE) Used with swines Used with Series Used with Series 66. 810. CH, SEF, SET. SETFL ST-WP HZ. M8DC. MTh, NH. NS, ST (M) MT-SUR-BOX BACKBOX (Q.) 4" SQUARE DEEP WI EXTENSION (U) 5" SQUARE BACKBOX WI ORDER CODES- RED: 500-693168 RING, FLUSH (BC) EXTENSION RING, FLUSH (BC) WHITE: 500-636118 SM TOP W' DEEP FI I 0 I Ii1— Used with Series C • CH,SE,SEF,SETFL,SET o (R) SFPS SEMI-FLUSH PLATE Used with Series HZ, SET ORDER CODES- RED: 600-636124, Used with Series (MTH. MTWP: Foi .sugface mounting on MT products.) WHITE: 500-636125 CI-1.SE,SEF. SET Stamped aluminum surface wal piate, (N) DBBS BACKBOX which mounts b&iind the basic unit, (V) SSB4 CEILING SUPPORT BRIDGE ORDER CODE - RED: 500-636111 and serves to cover recessed backboxes - 0 Standard steel backbox provided with knockouts in for interior surface mounting, concealed conduit mounting or serni4lush applications. p--.- 4 ....... semi-hush mounting applications. 8 HS ] HOLES 1 oJ. 0 5 14 Ue sedwlhS nes _' i' P1 SET E N9 NS ST Provisions for (4) J nuts #8-32 lb 331 PROOED WIT-i KIIOCKoula—" FOP. .atccnrDUrts. Square Material: Steel Used with Series (S) APS ADAPTER PLATE Used with Series ORDER CODE - RED: 500-636109 SE AH, AS. BC, 910, HS, MBOC, M14115, MTH. NH..SETSF, ST Stamped aluminum adapter plate designed for (X) SHBBS appkations where serni-Cush installations cannot octagon or round backboxes single or double Wg SQUARE, SURFACE BACKBOX ORDER CODES - RED: 500-636126, (0) RETROFIT PLATE ORDER CODES - [PENDING] boxes or ptester rings. The bacthox and basic unit WHITE. 500-636127 - 5,7 •• are then fastened to the plate. This type of mownting - rii iiJ 1 ••• is referred to as'concealed conduit installation.' '111"r .iE1 F ' '1 I) I ______t On _ HOLES °O e" 6 :i.. L _____ °o Used with Series Used with Series Used with Series 88, 810, MBDC,MTH,, NH, SE Be. 810, MBOC AH, AS, NH, ST SIEMENS Industry, Inc. Building Technologies Division SERS SQUARE SEMI-FLUSH (BB) SPSSB (EE) SPEXT EXTENSION RING EXTENSION RING ORDER CODES- RED: 500-636114, ORDER CODES - RED: 500-636116, ORDER CODES- RED 500 636122 WHITE: 500-636123 TOP WHITE: 500-536115 WHITE: 500-636117 [i 3 j1 L I ®®0,644 Used Used with Series 32 I Used with Series 7 _ mount speakerfstrobe) Used with gems SMt.0 (Ceiling Mourn Strobes SBL2S BACKBOX (CC) SB-W 8" CEILING SUPPORT BRIDGE ORDER CODE- RED: 500-636121 ORDER CODE - WHITE: 5t10-634882 (FF) ZBB IuiiL r- 23.150 TYP ________ ORDER CODES - RED: 500-636193, WHITE: 500-636194 lot J J 90 0 [ j 1_Jc•_fl_JJ -J' j6 -6X8—- '.32 il. FORWED THREAD \\.JLJL-=-JLJLIY U Used with Series Used with Series -- Used vAth Series ST S & Ceiling Speakers (AA) SPSB (DD) (GG) WFPS PLATE (HH) WFPAS PLATE ORDER CODES- RED: 600-636112, WHITE: 500-636113 " ORDER CODES - RED: 500-636135. WHITE: 500-636136 ORDER CODES - RED: 500-363133, WHITE: 500-656134 TOP 0 S.03 L E311 001 1 ® t' J±JLI Used Mth Series Used with Series MTWWP sTwp Used with Series AS-WP Used with Series SE (Speakers) S8' Ceiling Speakers I I I I I SIEMENS Industry, Inc. Building Technologies Division I 1 I I I I 1 I I I I I I I > 3 CD -Q CC • x La _ > - 0 CD rD CD - o 0 CD _. C/C . CD CD CD CD 0-. )<e. CD CD - .J Ui C.J • w _: 0 __ C 0 - 0 -D o Ni -o - -' o Z - 0 CD CD C 0. '• m X - , CD 0 0 CO c CD Q0 CD CD CD C . . g9 9 -a CL - C/C CD 2. r CD -n kA - 0 -. CD CM > C 0 CD co Cl. 0 CD >< >< >< >< Series SET-C > >< >< >< < < >< < >< > >< >< I Series ST >( >< > < Series ST-MC-RETRO >< >< >( > >< >< Series MHII5 >< >< > Series SE >( )( > >< > > x x x > Series BIO-115 >< > > < < >< Series CH >< >< >< I >< I Series SETSF-B >< x > Series SETSF >< )< > > >< > >< '< >< >< Series MBDC > Series S-HQ > >< '< ' < > Series SET! SET Wall Mount >< >< X Series SE-C >< >< Series MH > >< > >< >< >< > >< Series MTH >< >< >< >< >< >< < '< >< Series NS/NH > - x >< >< >< >< Series HS >< >< > > >< >< >c > x Series AS/AH . w Series AH-WB(3), MT-WP(4), MTH > ISeriesZ - - .I m - - - m _ - m - I— m - _ I I Mounting Matrix (by Mode! Number) IIUffliilhi Irrr'rrrr " " r•r'__________ "r _____________ .hh Ii !!I[Ii!i! i'iifl uuILh1iil IH I1ii Ii IItIiIiii 1111 upI uluuli LI hull ii iliiI IllijI i lifi i rr FIBER r r'r1 111111 F -bF i I E1I1 II III•iI p1 !'I!!uuI 1 P1!' SIEMENS Industry, Inc. Building Technologies Division I I I I I I Li I I I I I I I I 11 Mounting Notes Caution: The mounting options figures show the maximum number of field wires (conductors) that can enter the back box used with each mounting option. If these limits are exceeded, there may be insufficient space in the back box to accommodate the field wires and stresses from the wires could damage the product. Although the limits shown for each mounting option comply with the National Electrical code (NEC), Siemens recommends use of the largest back box option and the use of approved field wires whenever possible to provide additional wiring room for easy installation and minimum stress on the product from wiring. Caution: Check that the installed product will have sufficient clearance and wiring room prior to installing back-boxes and conduit, especially if sheathed multi- conductor cable or 3/4" conduit fittings are used. Mounting hardware for each mounting option is supplied. Conduit entrances to the back box should be selected to provide sufficient wiring clearance for the installed product. When extension rings are required, conduit should enter through the back box, not the extension ring. Use Steel City #53151(1-1/2" deep) or #53171 (2-1/8" deep) extension rings (as noted in the mounting options) or equal with the same cut- out area. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the appliance. SIEMENS Industry, Inc. Building Technologies Division Use care and proper techniques to position the field wires in the back box so that they use minimum space and produce minimum stress on the product. This is especially important for stiff, heavy gauge wires and wires with thick insulation or sheathing. Do not pass additional wires (used for other than the appliance) through the back box "unless the back box is of a sufficient size to permit additional wiring as described in NEC 314.16 (B)". Such additional wires could result in insufficient wiring space for the appliance. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice, in accordance with Siemens Industry, Inc. standard terms and conditions. Back Box Mounting Siemens Wall-Mounted, Horizontal Strobe Appliances NFPA-72 (2007) 7.5.4.1 * —Wall-mounted appliances shall be mounted such that the entire lens is not less than 2030 mm (80 in.) and not greater than 2440 mm (96 in.) above the finished floor or at the mounting height specified using the performance-based alternative 7.5.4.5 7.5.4.2 - Where low ceiling heights do not permit mounting at a minimum of 2030 mm (80 in.), visible appliances shall be mounted within 150 mm (6 in.) of the ceiling. The room size covered by a strobe of a given value shall be reduced by twice the difference between the minimum mounting height of 2030 mm (80 in.) and the actual, lower mounting height. I I Back box Mounting Options* Series AS/AH Audible Strobe series ST-MC-RETRO (Flush and Surface Retrofit Plate) Horn Series NS Strobe Series Z and ST Strobe Series MTH Multi-tone 80 IN. 6 IN. 80 IN. 6 IN. 80 IN. 6 IN. 80 IN. 6 IN. 80 IN. 6 IN. (B) 1-Gang x 2" Deep - Flush (80) 771/' 81/2* 78 !8 7 I" 79 II 6 /8 (D) 4" x 4" x 1.5" Deep - Flush (80) 77 9" 83 1/i&" 77 /s 18 78 5/8" 7 i/s" 79 15/16" 6 1ll6 6 1116 (E) 4" x 4" x 2.125" Deep - Flush (80) 77' 9" 83 15/" 77 I" 8 1/8" 78 i/a" 7 i/a" 79 15/16' 6 1516 6 1516 (F) 2-Gang x 3.5" Deep - Flush (BO) 771/3 81W 78 Ia" 7 s/s" 79 1/8" 6 /8" 80 9116 5 71,6 5 71 (G) 2-Gang x 1.75" Deep - Surface (80) 771/2' 81W 78 I8' 7 /8 79 la 6 7/8" 80 9116 5 71,a, S 711 (M) MT-SUR-BOX Surface & Weatherproof (SP) 79 I8" 6 /8 6 /8 (P) SBBS Surface (SP) 79 1/4"6 14" 6 3/4" (U) 5" Square Back box WI Extension Ring, Flush (BO) 69 /2' 81/2' 83 !16" 77 " 7 ia" 78 118' 6 7/s" 79 /i&" 5 9l 5 'i& (X) SHBBS (SP) Shallow Surface 761/f 91/2' 7 7 i" 1 8 /8" 78 1/8" 7 Ia" (Z) SBL2S Surface (SP) 78" (FF) ZBB - 78 1/8" 7 /" More Back box Series CH Series SET-V Series SEF-C Series SET-C Chime Strobe Speaker Strobe Speaker Strobe Speaker Strobe Mounting Options- 801N. 61N. 801N. 61N. 80 IN. 61N. 801N. 61N. SBB Surface (SP) 77-3/4" 8-1/4" 79-3/16" 6-13/16' 77-3/4' 8-1/4' 77-3/4" 8-1/4" 4" x 4" x 2.125' Box w/ 1.5" 77-1/2" 7-1/2" 80 6" 78-1/2" 7-1/2" 78-1/2" 7-1/2" Extension Flush _Ring _-_ _(BO) (U) 5" Square Back box with 78" 7" 79-1/2" 5-1/2" 78' 7" 78" 7" Extension _Ring _- Flush (BO) SHBB (SP) Shallow Surface 4" x 4" x 1.5" Box w/ 1.5" 78-1/2' 7-1/2" 80" 6" Extension-Ring Plate - Flush (BO) __________ ______ ______ _______ Measured from Bottom of Back box Notes: (BO) = By Others (SP) = Siemens Product I I I I I I Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. I I Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 (So) L6T 5E4 / Canada December 2009 I FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 het dated 7/07 ( 1) URL: www.SBT.Siemens.com/FlS FAX: (905) 799-9858 I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. IEXSTING I 7165-00670144! Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: ModéfliXL and MXL-IQ fire alarm control units. Coded or noncoded; local, auxiliary, remote and central station proprietary service; automatic, manual waterilow, releasing service and sprinkler supervisory service when used as a remote station (protected premise) unit or proprietary fire receiving unit. Refer to listee's data sheet for additional detailed product description and operational considerations. Basic components: MMB-11, -21, -31/SMB-12, -22, -32 Main Control Board MKB-11, -21, -42, -51, -62 Keyboard/Annunciator Panel MPS-6, -12 Power Supply CRM-4 Relay Module CSM-4 Signal Module CZM-4 Conventional Zone Module BTX-1, BP-61 Battery Set Module MSE-21, -32, -3M2 Enclosure MSE-3M-D Enclosure Door Silent Knight 5128, 5129 Dialer/DACT (Listing No. 7300-0559:120) 1 - For use with Model MXL only. 2 - For use with Model MXL-IQ only. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's listed Model VoiceCom system (CSFM Listing No. 6911-0067:173) and separately listed compatible initiating and indicating devices. See (CSFM Listing No. 7300-0067:172) for optional control unit accessories. *Also suitable for high-rise applications. Refer to listee's Installation Instructions Manual for details. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, *9th Edition Standard NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. *Rev. 06-23-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I I I I I I I I I I I I I I I Listing No. 7165-0067:0144 Page 2 of 2 2. Combined with 7170-0067:154 *Rev. 06-23-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -00670252 Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 I Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor I use on walls. Models ST-MC-CW ST-HMC-CW, ZMCCRZR-MC-CW ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. I Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. I RATING: Electrical 16-33V0C/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd I ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd ZR-HMC-CR, ZR-HMC-CW 1151177cd I Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix I -Ware wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. I MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. I NOTE: I I I I El I 9-1 O-2007mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 71250060248 Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division 8 Fernwood Road, Florham Park, NJ I 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com I DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns / Strobes. Models NS-MC-CR NS-MC-CW NS-HMC-CR, NSHMCcw1z141M: ZH-MC-Cw, ZH-HMC-CR, ZH-HMC-CW are horn / strobes for ceiling mount only. Suffix CR or CW are for ceiling and I color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR I Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115/177 cd NS-MC, ZH-MC = 15/30/75/110 cd ZH-HMC, = 135 / 185 cd I Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & I MARKING: ordinances and in a manner acceptable to the authority having jurisdiction. Listee's / UL label. name, model number, electrical candela rating and APPROVAL: Listed as audible and audible 1/ visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing I impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details I Note: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation ) in accordance with NFPA 72, 2002 Edition. NOTE: I I I 09-07-2007 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I POWER COMMUNICATION SYSTEMS, INC. rlS E:R' SALES - SERVICE - ENGINEERING Public Address • Paging • Intercom Fire Alarm • Nurse Call CCTV I WARRANTY Power Communication Systems, Inc. warrants its work and/or material supplied to be in substantial compliance with plans and specifications set forth. Material purchased from, and installed by Power Communication Systems, Inc., is warranted to be free from defects in material or workmanship for a period of one year from date of acceptance, or first beneficial usage, whichever occurs first. The undersigned does hereby agree to repair or replace at their own expense, during normal working hours, any equipment or workmanship provided and installed by them found to be defective. I They also agree to repair or replace at their discretion any materials sold by them and installed by others for a period of one year from date of sale. This is an over-the-counter warranty and is limited to materials returned to them with proof of purchase. This warranty shall not apply to any material sold or installed by Power Communication Systems, Inc. which has been subject to abuse, misuse, neglect, accident, or use contrary to instructions furnished. All I requests for warranty service must be accompanied by a valid Purchase Order and "Bill To" address. When applicable, invoices for warranty work will indicate "No Charge". I In the event the undersigned fails to comply with the above within a 30 day period after official written notification of failure or defect, the owner shall have the right to repair it at their discretion at Power Communication Systems expense. I POWER COMMUNICATION SYSTEMS, INC. I I I I I Ernest Power Ill Date P.O. Box 600066, San Diego, CA 92160-0066 4627-A Mission Gorge Place, San Diego, CA92120-4 133 I I I I