Loading...
HomeMy WebLinkAbout6860 AVENIDA ENCINAS; ; FA110032; PermitUttyot Uarlsbad Fire Alarm Permit Permit No: FA110032 6860 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: FALARM Applied 4/4/2011 Parcel No: 2144501900 Approved: 4/4/2011 Lot #: 0 Reference No.: Issued: 4/4/2011 PC #: Inspector: Project Title: KAISER MEDICAL TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: POWER COMMUNICATION SYSTEMS 4643-A MISSION GORGE PL SAN DIEGO, CA 619-583-7400 Owner: KAISER FOUNDATION HEALTH PLAN INC 393 E WALNUT ST PASADENA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 I so : POWER COMMUNICATION SY FA(16052, STEMS, INC. SALES - SERVICE - ENGINEERING 4,4 rn0 Public Address * Paging * Intercom * Fire Alarm * Nurse Call * CCTV I I I 0 0 SUBMITTAL FIRE ALARM SYSTEM KAISER PERMANENTE CARLSBAD MOB FIRE ALARM SYSTEM UPGRADE 6860 AVENIDA ENCINAS CARLSBAD, CA 92008 I I I I I I 1 I I I I I OWNER: I ELECTRICAL CONTRACTOR: FIRE ALARM CONTRACTOR: KAISER PERMANENTE FULLER ELECTRIC POWER COMMUNICATION SYSTEMS, INC. FA 1(0032. I P.O. Box 600066, San Diego, CA 92160-0066 • 4643-A Mission Gorge Place, San Diego, *California 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431—C7/C1O I I TABLE OF CONTENTS I LIST OF MATERIAL . . . . . . . . . . . 1 I UL CERTIFICATE . . . . . . . . . . . 2 NICET CERTIFICATE. . . . . . . . . . . 3 BUSINESS LICENSE . . . . . . . . . . . 4 I CUT SHEETS I 5000 MXL, MPS-6 . . . . . . . 5 5056 MME-KIT, MDL-1, MHD-2 . . . . . . 6 5079 MMB-3 . . . . . . . . 7 1 5026 MKB-2. . . . . . . . . 8 4000 5128C. . . . . . . . . 9 I 5073 3362 RCC-2 . . . . . . PAD-3. . . . . . . . . 10 . . 11 6175 FP-11, DB-11 . . . . . . . 12 I 6176 6187 FPT-11,DB-11 . . . . . MSI-10B . . . . . . . . 13 . . 14 6179 TRI-D, TRI-R . . . . . . . . 15 6170 TRI-136M . . . . . . . . 16 I . 2584 ZR-MC-CR,ZH-MC-CR . . . . . . 17 2585 MOUNTING APPLIANCES . . . . . . 18 SHEET 302-ET-135,AP-P . . . . . . . 19 C.S.F.M. LISTINGS 7165-0067:0144 MXL, MMB-3, MKB-2, MPS-6,5128C . . . . 20 I 7300-0067:0172 MME-KIT, MHD-2 . . . . . . . 21 7300-0067:0152 RCC-2 . . . . . . . . . 22 7135-0067:0221 PAD-3. . . . . . . . . 23 I 7272-0067:0203 FP-11 . . . . . . . . . 24 7270-0067:0202 FPT-11 . . . . . . . . 25 7300-0067:0134 DB-11. . . . . . . . 26 I 7150-0067:0036 MSI-10B . . . . . . . . 27 7300-0067:0146 TRI-D, TRI-R, TRI-136M . . . . . . 28 I 7125-0067:0252 7125-0067:0248 ZR-MG-CR . . . . . . ZH-MC-CR . . . . . . . 29 . . 30 7270-0021:0001 302-ET-135 . . . . . . . . 31 I WARRANTY . . . . . . . . . . . . 32 I I LIST OF MATERIAL MODEL NO. MANUFACTURER DESCRIPTION QTY MXL SIEMENS FIRE SAFETY FIRE ALARM CONTROL PANEL 1 MME-KIT it " KIT INCLUDES MME-3 & MBR-MP 1 MDL-1 MHD-2 It " " it PLEXIGLASS DOOR INSERT BOTTOM, DEAD FRONT, NO OPENINGS 1 1 MMB-3 " it MXL MAIN BOARD - FAST PROCESSOR 1 ' MKB-2 MPS-6 " " it " DISPLAY/CONTROL KEYBOARD HINGED MXL 6 AMP POWER SUPPLY 1 1 5128C " " 3 CHANNEL SLAVE COMMUNICATOR 1 RCC-2 REMOTE/CONTROL ANNUNCIATOR SMALL 1 PAD-3 " " P/S NAC EXT 6 AMPS 2 FP-11 " " SMOKE DETECTOR 3 FPT-11 HEAT DETECTOR 4 DB-11 " " DETECTOR BASE 7 MSI-10B " " MANUAL PULL STATION 26 TRI-D DUAL INPUT MODULE 1 TRI-R " " SINGLE INPUT WITH RELAY 1 TRI-136M " " MONITOR MODULE 4 ZR-MC-CR STROBE - CEILING 87 ZH-MC-CR " " HORN/STROBE - CEILING 23 302-ET-135 THERMOTECH HEAT DETECTOR 2 AP-P " it ADAPTER PLATE 2 I I 1 I I I I I I ID No: 66001 Underwriters Laboratories Inc ®Applican' & Service Center No Nurhb!orjk. IL 5n .os-. CA Expires: 1-MAR-2011 Mti.i. NY A out-to orr!n icateO to pt afe and cornmitted to quF strvic S CERTIFICATE OF COMPLIANCE I S . THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters UL Listing Mark in with Laboratories Inc. (UL) in its Product Directories as eligible to use the connection Certificated Alarm Systems. The only evidence of compliance wiTh A's requirrnents Is the issuance of a UL Certificate for the Ala,-rr System and the Certificate is current jr ier UL's Certiicate Verification Service. I This Certificate does not apply in any way to the communication cl-annel between the pntected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. SAN DIEGO CA Listed Service From: ' I Alarm Service Company (967165-001) Service Cento (967165-001) POWER COMMUNICATION SYSTEMS INC POWER COMMUNICATION SYSTEMS INC MISSION GORGE PL 4643A MISSION GORGE PL I 4643-A • SAN DIEGO CA 92120 SAN DIEGO CA 92120 The Alarm Service Company Is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category : S3669 -1 UUJS [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and ( S Proprietary ***THIS CERTIFICATE EXPIRES ON 31-MAR-201 "LOOK FOR THE UL ALARM SYSTEM CERTIF1ATE" I O2APR-2010 2008 UL Fomi CS-CC S S & ••/ 5, •'- )'5 ,:, 5'S •5 •. • SS•S •SS A i,.,'AA ' I I I I I 1 I I I I I I 1 I I I . F I I I NATIONAL'INSTITUTE FOR- CERTIFICATION. IN ENGINEERING ,TECHNOLOGIE'So HEREBY CERTIFIES THAT Ernest Power, III HAS ATTAINED THE GRADE OF LEVEL III IN FIRE PROTECTION ENGINEERING TECHNOLOGY FIRE ALARM SYSTEMS AND RECOGNIZES THAT THROUGH EDUCATION, EXPERIENCE, AND KNOWLEDGE THIS PERSON HAS MET THE STANDARDS SET FORTH BY THIS INSTITUTE Certification Valid through September 1, 2011 CERTIFICATION NUMBER 77846 - CHA AN OF THE BOARD OF GOVERNORS, NICET SPONSORED BY THE NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS I I I I I I 1 I I 1 I I I I I I I I I State 0 Ca ifcmia CONTRACTORS STATE LICENSE BOARD ACTIVE LICENSE Consumer 636431 Eritil POWER COMMUNICATION SYSTEMS INC h .il iticri(s C-7 E1 0 lllII thL E,dtvrI Date.0 1/3 1/20 1 2 SIEMENS Catalog Sheet Fire Safety & Security Products MXL Advanced Protection System ARCHITECT AND ENGINEER SPECIFICATIONS MXL Panel FirePrinP application-specific detection More than 2,000 intelligent input-device capacity Multiple Command Stations Dynamic supervision of Intelligent Devices Security-device monitoring Sprinkler supervision Detector-sensitivity readout! printout, per NFPA 72 Chapter 7 Intelligent! Analog detection circuits: - Style 6 (Class A) or Style 4 (Class B) Conventional initiating circuits: - Style D (Class A) or Style B (Class B) Notification appliance circuits: - Style Z (Class A) or Style Y (Class B) Degrade-mode operation Distributed processing 80-character backlit, alphanumeric display 32-character custom messages Thermal-strip printer Supervised remote printer Compare system software Fully field programmable, via laptop PC Menu-driven operator commands Central & distributed architecture Up to 800-event history log with online & off line reports User help screens Holiday schedule System Overview Logic-controlled output functions Multiple levels of password protection Automatic environmental compensation for smoke detectors One-person 'walk test' via 'loop,' 'zone' or 'system' Alarm verification by 'device' or 'zone' Time-base controlled output functions City Tie! Lease Line Coded outputs Supervised serial annunciator Driver! Input Interface 16-gauge steel enclosure Multi-language display Intelligent interface to building! process management systems Operates as an interactive peer with other MXL, MXL-IQs or MXLV systems in a LifeLINK Network Pre-alarm operation NCC graphics Pre-action Releasing (NFPA 13) Halon & SilborixTM Approval (NFPA 12A& NFPA 2001) NEC 760 Power Limited Circuits (€UL 864 Compliant) UUKL Listed for Smoke Control eUL 864 9th Edition Listed, OULC Listed; CSFM, NYMEA, City of Chicago and U.S. Coast Guard Approved I I I I I I I I I I I I I The MXL fire panel is a microprocessor-based I advanced protection system. The use of the MXL system's unique multiprocessor 'Network' design; as well as its ability to utilize analog and conventional detection devices, makes the MXL panel a highly I flexible and reliable fire-control system. The MXL panel is ideally suited for commercial, I institutional and industrial fire-detection and notification applications. The MXL system complies with the requirements of NFPA Standard 72, and is listed by Underwriters Laboratories (UL), via their ®UL 864 gth Edition. tUnderwriter's' I Laboratories of Canada (ULC) also lists the MXL panel for fire applications. The MXL system is I SIEMENS Industry, Inc. I Building Technologies Division approved by CSFM, the City of Chicago and NYMEA for use in those specific locales. In addition to the standard fire applications, MXL is also listed by ®UL - under the category 'UUKL for Smoke Control.' The MXL panel can be used as a listed fireman's smoke- control station in high-rise office buildings, malls and other multi-level or vast structures. The MXL system also complies with Uniform Building Code Section 905 requirements for smoke control. MXL is approved by the US Coast Guard for marine applications such as ships and oil drilling platforms. The MXL panel is listed by ®UL for releasing Halon 1301, SinorixTM Engineered Fire Suppression System and MXL 5000 System Overview -(continued) pre-action or deluge sprinkler systems. These include foam or water applications. MXL follows the releasing requirements specified in the NFPA Standards 12A, 13 and 2001. MXL Components The basic MXL control unit consists of the following sub-assemblies: MMB-3 Main Control Board; MPS-6! MPS-1 2 Power Supply; MKB-2 Annunciator and Keyboard; MME-3, MLE-6 or MSE-2 Enclosures. Optional modules -which can be installed with the MXL System - include: MOM-2/4 Expansion Card Cage; ALD-21 Analog Loop Driver; CRM-4 Controllable Relay Module; NIM-i W Network/Foreign Systems Interface Module; REP-1 Network Repeater Module; XLD-i "X" Series Loop Driver; CSM-4 Controllable Signal Module; CZM-4 Conventional Zone Module; PIM-i Peripheral Interface Driver; CMI-300 CXL Modem Interface Module; PSR-i Remote Power Supply; MXL-VDT Interactive Video Display Terminal; NET-4 Style 4 Network Interface; NET-7 Style 7 Network Interface. Additionally, the MXL system includes option modules MOI-7 System Interface, MOD-16 Output Driven and MID-16 Point Input Module. These option modules can be used to drive graphic annunciators and Fireman's Smoke Control Stations, or to monitor foreign systems. The MXL is compatible with a full line of intelligent initiating devices highlighted by the FirePrintlM application-specific detectors: Models FP-1 1 and FPT- ii. The MXL panel is also compatible with FireFinder, the NCC series of text and graphic command centers. MXL Enhanced Main Board (MMB-3) MMB-3 The function control of the MXL is contained on the MMB-3 Main Control Board. Model MMB-3 offers a fast, integral microprocessor and installation conveniences such as diagnostic LEDs and removable terminal blocks for field wiring. Model MMB-3 acts as the central controller for the system, and includes two (2) ALD circuits and two (2) notification appliance circuits. Model MMB-3 mounts in the MXL enclosure backbox. SIEMENS Industry, Inc. Building Technologies Division Display I Keyboard (MKB-2) MKB-2 The MKB-2 display! keyboard mounts on a hinged frame in the MXLV enclosure, and provides: Two-line, 80- character LCD display indicator LEDs display-control keys numeric keypad user-programmable function keys all other keys necessary for operator control These keys include but are not limited to: Acknowledge; Silence and Reset. Model MKB-2 also includes spaces for mounting the Model MMM-i microphone module and the Model TMM-i telephone. Model MKB-2 is supplied with two (2) blank plates for use when either the microphone or telephone is omitted. Display I Keyboard (MKB-5) MKB-5 The MKB-5 display! keyboard mounts on the inner door of any MXL enclosure backbox and provides: 6-1I4 VGA backlit, 80- character LCD display indicator LEDs 12 programmable function keys numeric keypad user-programmable function keys all other keys necessary for operator control These keys include but are not limited to: Alarm; Supervisory; Trouble and Security. Multiple MKB-5s can be used in the system, each providing full control of the MXL system. Up to four (4) Model MKB-5 can operate in a fully supervised mode; each with independent printer driver capability built-in. MXL Components - (continued) Model MPS-6 is a fully supervised power supply that provides the MXL system with primary DC power. Model MPS-6 is rated at 6.5 Amps, and is unfiltered and unregulated. Model MPS-6 supplies power to the MXL Control Unit, and supplies its expansion modules with power required for normal operation. Model MPS-6 incorporates a circuit breaker on the primary input, and includes a built-in AC-line filter for surge and noise suppression. Model MPS-6 mounts in the MXL enclosure backbox. Power Supply (MPS-12) Network Optional Module Card Cage (MOM-2) MOM-2 Model MOM-2 provides the MXL main unit, remote units or MXL small enclosures (Model MSE-2) with card slots for optional modules. Each Model MOM-2 provides space for one (1) full-width module (Models: ALD-21, CZM-4, and NIM-i R) or two (2) half-width optional modules (Models: CSM-4, CRM-4, CMI-300, NET-7, REP-1). Analog Loop Driver (ALD-21) I I I I I I MPS-12 Model MPS-1 2 is a fully supervised power supply that provides the system with preliminary DC power. Model MPS-12 is rated at 12 Amps, and is unfiltered and unregulated. Model MPS-12 supplies power to Models PSR-1, MMB-2 and their expansion modules with power required for normal operation. Model MPS-12 incorporates a resettable circuit breaker on the primary input, and includes a built-in AC-line filter for surge and noise suppression. Model MPS-12 mounts in the MXL enclosure backbox. Network Optional Module Card Cage (MOM-4) —-?-'?. MOM-4 The Model MOM-4 Card Cage provides the MXL main unit or remote units with card slots for option modules. Each Model MOM-4 supplies connection space for either two (2) full-width option modules: (Models ALD-21, CZM-4, NIM-1 R, XLD-1) or four (4) half-width option modules: (Models CSM-4, CRM-4, CMI-300, NET-7, REP-1) or a combination of one (1) full and two )2) half-width modules. SIEMENS Industry, Inc. Building Technologies Division ALD-21 Model ALD-21 is a MXL network-option module that supplies two (2) intelligent analog circuits utilizing Fire Safety "1", "IL, and FP series intelligent devices. Model ALD-21 occupies two (2) addresses on the MXL Network and through the use of unique communication-protocol devices connected to the circuits of Model ALD-21. The circuits are dynamically supervised by the MXL control panel. Up to 60 programmable input and output devices may be connected to each of its two (2) circuits. Each circuit may be wired as Class B (Style 4) or Class A (Style 6). Controllable Signal Module (CSM-4) CM-4 Model CSM-4 provides two (2) fully supervised, programmable notification-appliance circuits. Model CSM-4 supplies two (2) Class B (Style Y) or Class A (Style Z)-type output circuits for the supervision and control of listed audible or visual notification appliances such as: horns, bells, strobes, etc. Each circuit can provide up to 1.5 amps (24 VDC) of current to power notification appliances. Model CSM-4 is also used for suppression-agent releasing (SinorixTM, Halon, Pre-Action Sprinkler and Deluge) systems. Leased line and municipal-tie connections are also possible with Model CSM-4. I I I I I U I [1 I U I 1 I MXL Components - (continued) Controllable Relay Module (CRM-4) - i1!1flUt!U,j 1E1 ti I iiirW CRM-4 Model CRM-4 is designed to provide auxiliary control of building functions such as: door- holder release, elevator capture, smoke control, lock release, etc. Model CRM-4 provides four (4) fully programmable relays. Each relay contains one (1) set of SPDT contacts rated at 2 amps 30 VDC /120 VAC resistive. Communication Module (NET-4) NET-4 Model NET-4 is a plug-in-type module used to provide communication between the Fire Safety MXL panel and various other MXL remote modules. Model NET-4 is designed to plug into an edge-connector-type slot on the Model PSR-i Network Supply. Model NET-4 provides NFPA Style 4-type communication: fully digital; RS-485 operating at 19.2K Baud rate. Style 7 Network Interface Card (NET-7) ;1 ••_• -. -- NET-7 Model NET-7 is a microprocessor-controlled MXL network-interface module that allows the wiring of the MXL RS-485 network in a NFPA Style 7 configuration. Model NET-7 plugs into a half slot of the Models MOM-2/4 card cage at the MXL command center (MMB-2) and at the Model PSR-1 or Model MOM-4 slot at the MXL remote units (MXLR, MXLRV). SIEMENS Industry, Inc. Building Technologies Division Model NET-7 provides two (2) independent and fully supervised communication paths, allowing system operation through an open and short circuit. Model NET-7 also isolates the power supplies at each remote unit, providing the ability to localize ground-fault conditions. The communication for Model NET-7 operates at 19.2K Baud rate and is fully digital. Network Repeater Module (REP-1) wflWll1Uk,LI r 1 v- ir REP-i Model REP-1 provides the ability to configure the local or global networks of the MXL panel in a 'star' or 'daisy-chain' configuration. Model REP-11 provides two (2) Style 4 or one (1) Style 7 RS-485 network circuits. Through the use of Model REP-1, the MXL's local network (MXL-MXLR) can be expanded up to 64 nodes. Remote Power Supply (PSR-I) PSR-1 Model PSR-1 is a microprocessor-controlled remote power supply and battery charger for use with the MXL panel. Model PSR-i operates in conjunction with either a Model MPS-6 or MPS-1 2, providing 6 or 12 Amps of power for use with various MXL modules. When used with a Model NET-4 or Model NET-7 plug-in communication module, Model PSR-i becomes a part of the MXL panel's internal network. Model PSR-1 acts as an interface between remote-option modules and the MXL. MXL Components - (continued) Peripheral Interface Driver (PIM-1) 'IM-1 Model PIM-i is a MXL option module that provides a bidirectional, isolated RS-232 port for connection to peripheral devices, such as: printers, CRTs, VDTs, color graphics, alphanumeric pagers and remote diagnostics hardware. Model PlM-i mounts in the MXL enclosure, and connects to Model MMB-3, providing a screw-terminal block for connection of RS-232. A number of supervised and non-supervised formats are available for Model PlM-1. Output I Input Module (MOI-7) MOI-7 Model M0I-7 is a MXL RS-485 network module that provides a fully programmable serial interface to Model MOD-1 6 output drivers and MID-1 6 input drivers. When used with Model MOD-16 drivers, Model M0I-7 provides a serial-annunciator output or relay driver. When used with Model MID-16, Model M0I-7 provides programmable inputs. Each Model M0I-7 can operate up to eight (8) Model MOD-1 6 drivers and eight (8) Model MID-1 6 drivers simultaneously. Each Model MOD-1 6 output and Model MID-1 6 input is independently programmable, via the MXL custom software. MXL /(V) Standard Size Enclosure (MME-3) MME-3 Output Driver (MOD-16) MOD-16 Model MOD-1 6 is an output-driver module used in conjunction with Model M0I-7, as a part of the Fire Safety MXL System. Up to eight (8) Model MOD-1 6s can be connected to a Model M0I-7 interface module. Each Model MOD-i6 provides 16 open-collector, current-sinking outputs, which are rated at 24 VDC, 50mA. Model MOD-16 outputs are programmable, via the MXL custom software. Programmable Input Driver (MID-16) MID-16 Model MID-1 6 is an input module used in conjunction with Model M0I-7, as a part of the Fire Safety MXL System. Up to eight (8) Model MID-1 6s can be connected to a single Model M0I-7, along with eight (8) Model MOD-1 6 output-driver modules. Each Model MID-16 provides a non-supervised input, which can monitor normally open contact devices. Each Model MID-1 6 input can be separately used as a part of the MXL custom programming logic. These inputs can be individually set for: Alarm, Supervisory, Trouble, Security or Status usage. Further, the Model MID-1 6 inputs can also be configured to provide supervision for lamps driven by Model MOD-1 6 outputs. Screw terminals and connectors are provided on the Model MID-1 6 modules for interface to monitored devices. SIEMENS Industry, Inc. Building Technologies Division MXL Components - (continued) The Model MME-3 enclosure set consists of a sheet- metal back box and door with key-lock. Model MME-3 can be used for the MXL System, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (via the Model MSR-1 Rail Kit). To mount MXL I MXLV modules in Model MME-3, the Model MBR-MP removable-module mounting plate is required. Using the Model MBR-MP mounting plate -one (1) Model MMB, or one (1) Model PSR-1, and up to three (3) expansion cardcages (Model MOM or Model 0MM) can be mounted in the Model MME-3 enclosure. When used to mount MXL amplifiers (Model EL-410), the Model MBR-MP module is not required. Instead, up to three (3) Model EL-410 amplifiers may be installed in Model MME-3, via three (3) Model MSR-1 Rail Kits. When amplifiers are mounted in any enclosure, always install Model MDG-1 grills in the door for proper ventilation. Model MME-3 is designed for surface of semi-flush mounting, and includes various knockouts for wire and conduit entry. The door in the Model MME-3 set has two (2) cutouts for clear lenses, blank plates or grills - depending on the application - and contains a key-lock. MXL MME-3 and MLE-6 Modules Mounting Plates (MBR-MP) MBR-MP The Model MBR-MP MXL IV Module Mounting Plate is required for use in both Models MME-3 and MLE-6 enclosures in order to mount all MXL and MXLV equipment. Model MBR-MP is not necessary if the Models MME-3 and MLE-6 enclosures are to be used only for mounting of amplifiers (EL-41 0) Model MBR-MP is a removable MXL /V module mounting plate that allows the Model MME-3 or Model MLE-6 enclosure to be shipped to the job site for wiring and conduit installation, while the system hardware (electronics) is mounted to the studs on Model MBR-MP - pre-wired, programmed and tested - prior to delivery and installation at the job site. This process allows for faster, more efficient system start-ups with less chance of the sensitive electronics being damaged while field wiring and conduit are connected to the system enclosure. SIEMENS Industry, Inc. Building Technologies Division The Model MBR-MP mounting plate bolts to the Model MME-3 or Model MLE-6 enclosures for easy installation on the job site. Model MBR-MP also has handles to allow easy transport and mounting. The MBR-MP contains mounting studs for one (1) Model MMB or Model PSR-1; one (1) Model PlM-1; one (1) Model TBM-2, and up to three (3) Model MOM or Model 0MM card cages or two (2) cardcages and one (1) TSP-40 Printer (same mounting studs as the Model MBR-2 enclosures). Model MBR-MP is ordered and shipped separately from the Models MME-3 and MLE-6 enclosures. MXL 1(V) Large Size Enclosure (MLE-6) MLE-6 The Model MLE-6 enclosure set consists of a sheet-metal back box and door with two (2) key-locks. Model MLE-6 can be used for the MXL system, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (via the Model MSR-1 Rail Kit.) To mount MXLIV modules in Model MLE-6, the Model MBR-MP removable module mounting plate is required with the Model MBR-3MP option available for use. Using the Model MBR-MP mounting plate, one (1) Model MMB or Model PSR-1 and up to three (3) expansion cardcages (Model MOM or Model 0MM) can be mounted in Model MLE-6. If additional card cages are required, the Model MBR-3MP optional card cage mounting plate can also be installed in Model MLE-6 - below the MBR- MP. Model MBR-3MP allows mounting of an additional three (3) Model MOM or Model 0MM module expansion cardcages. Various combinations of hardware can be installed in Model MLE-6. If only amplifiers are to be installed in Model MLE-6, no Model MBR-MP or Model M13R-3MP plates are required. Instead, up to five (5) Model EL-410 amplifiers can be installed by using five (5) Model MSR-1 rail kits. The Model MLE-6 can also be used to mount up to three (3) MXL cardcages and two (2) amplifiers. This configuration would be typical of a remote, voice transponder cabinet. In this configuration, one (1) Model MBR-MP would be used in the upper half of Model MLE-6 to mount the MXL modules, while the lower half would use two (2) Model MSR-1 rail kits to mount up to two (2) Model EL-41 0 amplifiers. MXL Components - (continued) Model MLE-6 is designed for surface or semi-flush Mounting, and includes various knockouts for wire and conduit entry. The door supplied with the Model MLE-6 set has three (3) cutouts for either clear lenses, blank plates or grills - depending on the application. The door also contains twp (2) key-locks, which are keyed the same. Various combinations of dead-front mounting plates are possible with the Model MLE-6 enclosure A typical MXLV installation would have one (1) Model MKB-2 at the top, and two (2) Model MHD-3 dead- front plates in the middle [for 14 VSM I VLM I VFM modules per plate] and one (1) or two (2) Model MHD-2 lower dead-front plates. MLE-6 Optional Cardcage Mounting Plate (MBR-3MP) MBR-3MP Model MBR-3MP is an optional MXL I MXLV card cage mounting plate for use exclusively in the Model MLE-6 enclosure. When installed in the Model MLE-6 backbox, Model MBR-3MP adds the option of mounting up to an additional three (3) Model MOM or Model 0MM expansion card cages. Clear Lens (MDL) MDL Model MDL is a clear Plexiglas® lens that fits in one (1) of the two (2) openings in the Model MME-3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One (1) lens is included in the Model MDL-1 package Sheet Metal Blank Plate (MDB-1) MDB-1 Model MDB-1 is a sheet-metal blank plate that fits in one (1) of the two (2) openings in the Model MME-3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One (1) blank plate is in the Model MDB-1 package. SIEMENS Industry, Inc. Building Technologies Division Upper or Middle Dead-Front Panel (MHD-1) MHD-1 Model MHD-1 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the upper or the middle section of the Model MME-3 backbox, or the upper or either of the two (2) middle sections of the Model MLE-6 backbox. Model MHD-1 has an opening with a cover plate for the Model TSP-40 printer (when used), and attaches to the backboxes with screw fasteners. Once in place, Model MHD-1 covers and protects modules and wiring; providing dead-front construction to that area. Lower Dead-Front Panel (MHD-2) MHD-2 Model MHD-2 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the lower section of the Model MME-3, and on the lower two (2) sections of the Model MLE-6 backbox. Model MHD-2 has no openings and attaches to the backboxes with screw fasteners. Once in place, Model MHD-2 covers and protects modules and wiring; providing dead-front construction to that area. Middle Dead-Front Plate for Mounting Switch and LED I Fan-Control Modules (MHD-3) F-1.1 MHD-3 Model MHD-3 is a hinged sheet-metal panel that attaches to the Model MME-3 or MLE-6 enclosure backbox, and fits in either the middle of the upper sections of the Model MME-3 or MLE-6 enclosures. Model MHD-3 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Model MHD-3 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Each row can mount up to seven (7) modules, totaling 14 modules for each Model MHD-3. Model MHD-3 attaches to the backboxes with screw fasteners, and is hinged for easy access to the rear of the modules inside the enclosure. I ii I I I I I I I I I I I I I I I I I MXL Components - (continued) Middle Dead Front Plate for the Switch/LED! Fan-Control Modules with Printer Cutout (MHD-4) Model MHD-4 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure backbox, and fits in the middle section of both enclosures. Model MHD-4 has openings for two (2) rows of Model VSM-1 Switch Modules; Model VLM-1 LED Annunciator Modules; Model VFM-1 Fan Control Modules, or Model VSB-1 Blank Plates. Each row has space to mount four (4) modules, totaling eight (8) modules for each Model MHD-4. Model MHD-4 also has a cutout to display the Model TSP-40 Internal Thermal Strip Printer. Model MHD-4 mounts to the backboxes with screw fasteners, and is hinged for easy access to the rear of the modules and inside of the enclosure. When in place, Model MHD-4 covers and protects modules and wiring, providing dead-front construction to that area. When the Model MLE-6 enclosure is used with the Model MBR-MP mounting plate for installation of MXL or MXLV equipment, up to two (2) Model MSR-1 Rail Kit rows can also be installed in Model MLE-6 for mounting of either two (2) Model EL-410 amplifiers or some complement of System 3-type mount modules. MPS-1 2 transformer! supply, can accept NET-4 or NET-7 network interfaces, and includes diagnostic LEDs and two (2) system relays. Model PSR-1 mounts in the upper section of the MXL enclosure backbox. MXL Small Enclosure (MSE-2) MSE-2 Model MSE-2 is a small MXL enclosure capable of housing an MMB-2 or PSR-1 and MPS-6 or MPS-1 2. When expansion is required the MSE-2 provides for mounting of either one (1) MOM-2 or OMM-2. MSE-2 is part of the MXL-SS and MXLV-SS packages. Thermal Strip Printer (TSP-40A) Rail Kit (MSR-1) S MSR-1 TSP-40A Model MSR-1 is a System 3TMtype rail kit that fits into either the Model MME-3 or MLE-6 enclosure backbox. Model MSR-1, which comes with a U-bracket and a Z-bracket, allows the following modules -or any other System 3-type module - to be mounted in the Model MME-3 or Model MLE-6 enclosure: Model EL-410 amplifier Model PS-35 power supply Model BC-35 battery charger Model M01-7 I/O interlace Model MID-1 6 input driver Model MoD-i6 output driver Model PS-5A power supply Model SYS3-MPFO [for mounting the D2300CP fiber-optic interface modules, or the ccu pager interface] When used in the Model MME-3 enclosure three (3) Model MSR-1 Rail Kits can be installed to mount up to three (3) rows for up to three (3) EL-41 0 amplifiers. When used in the Model MLE-6, up to five (5) MSR-1 Rail Kit rows can be installed to allow mounting for up to five (5) EL-410 amplifiers. SIEMENS Industry, Inc. Building Technologies Division Model TSP-40A is a thermal strip printer, designed as an event-logging device for the MXL panel, providing a permanent-history report of all system activity. Model TSP-40A mounts in the MXL enclosure, and its printout is visible through a window in the locked-door enclosure. Printouts are automatically spooled on a take-up reel for easy records storage. Remote Command Console (RCC-1) RCC-1 Model RCC-1 is a remotely located MXL annunciator display module. Model RCC-1 contains an 80-character LCD display and control keypad (MKB), as well as a PS-51\17 network interface. MXL Components - (continued) Model RCC-1 modules can be located anywhere that annunciation or control is required. Model RCC-1 can be programmed for display only, or can provide display and system control. Remote printers, VDT, or graphics computers can be located throughout a facility -if Model PlM-1 is added to Model RCC-1. ®UL Listed Parallel Printer (PAL-11) 5-Volt Power Supply I Network Interface (PS-5N7) I I I I r)-p1, PAL-1 Model PAL-1 is a UL Listed, supervised parallel-system printer for the MXL panel. Model PAL-1 connects to Model MKB-5 to provide the MXL panel with a ®UL Listed, supervised parallel-system printer. B6 Intelligent Control Point (ICP) ICP Model ICP is a field-mounted output module that is capable of being programmed to either a remote bell or horn -or to a speaker or telephone zone. Model ICP communicates with the MXL fire panel, via ALD loop. Line-Isolator Module (LIM-1) LIM-i Model LIM-i is a short-circuit isolator module for use on the analog loops of the MXL panel. Model LIM-1 is capable of providing Style 4 or Style 6 wiring of the ALD loop. Multiple short-circuit isolators can be used on a single ALD loop to prevent loss of protection in the event of a short circuit. Model PS-5N7 is a 5V power supply and MXL local-network interface module. Model PS-51\17 is an integral part of Model RCC-1 - Model PS-51\17 can be used to provide a Style 4 or Style 7 network interface for either a remote transponder for the MXLV panel (with either Model TBM-2, ACM-1 and VSM-i I VLM-i I VFM-1), or to drive Model 0MM-1 and associated MXLV cards. 5-Volt Power Supply (PS-5A) Model PS-5A provides 5 Volts for powering Model MOI-7. Model PS-5A obtains its power from the 24-Volt power supply in the MXL system. Models MOI-7 and PS-5A both mount on System 3 rails, and can also be mounted externally to the MXL system. Models M0l-7 and PS-5A typically drive remote-graphics annunciators or monitor foreign systems and devices. Network Interface Module (NIM-IW) NIM-1W Model NIM-1W allows for the interconnection or networking of up to 63 MXL panels. Model NlM-i W provides a RS-485 communications path in either Style 4 or Style 7 wiring configurations. Model NIM-1 W allows MXL panels to have inter-panel logic, as well as communicate in a peer-to-peer manner. Model NIM-iW can be programmed via CSGM logic as a Foreign System Interface to communicate with external-building management systems. I I Li I I I I I 1 I I I I I I SIEMENS Industry, Inc. Building Technologies Division Details for Ordering Model Number Siemens Installation- Sheet Number Description CZM-1 315-090725 Conventional Zone Module ILl-i I 1H! 1A! 1AH 315-092724 Intelligent Ion Detectors ILP-1 IlPLT-1 315-092594 Intelligent Photo Detectors ILl-i 315-093336 Intelligent Heat Detectors ILl-i B /1 BH 315-093234 Intelligent Ion High Velocity Detectors ILP-2 315-095028 FirePrintTM Application-Specific Detection MSI-1 OB I 20B 315-093329 Intelligent Manual Station MS-MI 315-092169 Intelligent Metal Manual Station TRI-136 I 1361)1 B6R 315-093315 Intelligent Monitor Module [single! dual with array] TRI-136M 315-094547 Intelligent Mini-Monitoring Module ICP 315-092471 Intelligent Control Point UM-1 315-092135 Line-Isolator Module FP-1 1 315-095921 Intelligent FirePrintTm Detector TRI-S!DIR 315-096242 Intelligent Monitor Module Note: For further details, refer to MXL IOM manual: 315-092036. Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario March 2010 Building Technologies Division Tel: (973) 593-2600 (S11) L6T 5E4 I Canada Supersedes ht dated FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 R,. URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 MLE-6 Door I I Catalog Sheet SIEMENS Fire Safety & Security Products MXL I MXLV Fire Alarm Enclosures & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MD13-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4u ARCHITECT AND ENGINEER SPECIFICATIONS I I I I I I I I I I MME-3 Door MME-3 Enclosure Enclosure & Door Package (MME-3) Standard Size MXL Enclosure Removable Module Mounting Plate (MBR-MP) Hinged Locking Door with Optional Inserts for Clear Lens, Grill, Blank Plate Mounting for (1) MMB or PSR-1, and up to (3) card cages (Model MOM or 0MM) 4&UL 864 9th Edition Listed, OULC Listed Enclosure Enclosure & Door Package (MLE-6) Large-size MXL Enclosure Removable Module Mounting Plates (M BR-M P & M BR-3M P) Hinged dual-lock door with optional inserts for Clear Lens, Grill, Blank Plate Mounting for (1) MMB or PSR-1, and up to (6) card cages (Model MOM or 0MM); or up to (3) card cages and (2) EL-410 amplifiers (MSR-1 Rail Kits) €UL 864 91h Edition Listed, ®ULC Listed I I I I I I MXL/MXLV 5056 I SIEMENS Industry, Inc. Building Technologies Division Product Overview The Models MME-3 and MLE-6 enclosures provide a complete set of hardware for mounting all MXL and MXLV modules for various system I size requirements. Included in the enclosure series are back box and door sets; removable mounting plates and clear lenses; louvered ventilation grill plates, and blank plates for use with the enclosure doors. Dead-front covers for standalone use - with switch and I or annunciator modules and a strip printer -are also available. The Models MME-3 and MLE-6 enclosures are approved for operation within the temperature range of 320 to 120°F (0°C to 49°C). MXL I MXLV Components MME-3 MXL I MXLV Standard Size Enclosure The Model MME-3 enclosure set consists of a sheet-metal back box and door with key-lock. Model MME-3 can be used for the MXL System; MXLV Voice Command Console; MXLR Transponder; MXLRV Voice Transponder, or Amplifier Equipment (using the MSR-1 Rail Kit). To mount MXL I MXLV modules into Model MME-3, the Model MBR-MP removable module mounting plate is required. One (1) MMBorone (1) PSR-1, and upto three (3) expansion card cages (Models MOM or 0MM) can be mounted in the Model MME-3 enclosure, via use of the Model MBR-MP mounting plate. When used to mount MXL amplifiers (Model EL-41 0), Model MBR-MP is not required, but up to three (3) Model EL-41 0 amplifiers may be installed into Model MME-3, via use of three (3) Model MSR-1 rail kits. When amplifiers are mounted in any enclosure, Model MDG-1 grills must be installed on the door for proper ventilation. Model MME-3 is designed for surface of semi-flush mounting, and includes various knockouts for wire and conduit entry. The door for Model MME-3, which contains a key-lock, has two (2) cutouts for clear lenses, blank plates or grills—depending on the application being used MBR-MP MME-3 & MLE-6 MXL Module Mounting Plate The Model MBR-MP MXL I MXLV module mounting plate is required for use in Models MME-3 and MLE-6 enclosures to mount all MXL and MXLV equipment. However, Model MBR-MP is not necessary if Models MME-3 and MLE-6 enclosures are to be used only for mounting of amplifiers (e.g. - Model EL-41 0). Model MBR-MP is a removable MXL/ MXLV module mounting plate that allows the Model MME-3 or Model MLE-6 enclosures to be shipped to the job site for installation of wiring and conduit; while the system hardware (e.g. -electronics) is mounted to the studs of Model MBR-MP, pre-wired, programmed and tested prior to delivery and installation at the job site. SIEMENS Industry, Inc. Building Technologies Division The aforementioned process allows for more efficient system start-ups; as well as a reduced chance of the sensitive electronics being damaged while field wiring and conduit are connected to the Models MME-3 and MLE-6 enclosures. The Model MBR-MP mounting plate bolts to either the Model MME-3 or MLE-6 enclosures for easy installation on the job site. Model MBR-MP also has handles to allow easy transport and mounting. Model MBR-MP contains mounting studs for one (1) Model MMB or PSR-1; one (1) PlM-1; one (1) TBM-1, and up to three (3) Model MOM or 0MM card cages - or two (2) card cages, and one (1) TSP-40 Printer (same mounting studs as the Model MBR-2 enclosures). Model MBR-MP is ordered and shipped separately from the Models MME-3 and MLE-6 enclosures. MBR-MP M BRA P (with MXL equipment connected) MLE-6 MXL I MXLV Large-Size Enclosure The Model MLE-6 enclosure set consists of a sheet-metal back box and door with two (2) key-locks. Model MLE-6 can be used for the MXL system; MXLV Voice Command Console; MXLR Transponder; MXLRV Voice Transponder, or Amplifier Equipment (using the Model MSR-1 rail kit). To mount MXL I MXLV modules into the Model MLE-6 enclosure, the Model MBR-MP removable module mounting plate is required, while Model MBR-3MP is optionally available for use. Using the MBR-MP mounting plate, one (1) MMB or PSR-1 and up to three (3) expansion card cages (Model MOM or 0MM) can be mounted into Model MLE-6. If additional card cages are required, the Model M13R3MP optional card cage mounting plate can also be installed inside Model MLE-6 - below Model MBR-MP. Model M13R-3MP allows mounting of an additional three (3) Model MOM or 0MM expansion card cages. Various combinations of hardware can be installed into Model MLLE-6. If amplifiers are the only equipment to be installed inside Model MLE-6, then, no Model MBR-MP or M13R-3MP plates are required. MXL I MXLV Components - (cont.'d) Instead, up to five (5) Model EL-41 0 amplifiers can be installed by using five (5) MSR-1 rail kits. Model MLE-6 can also beused to mount up to three (3) MXL card cages and two (2) amplifiers. This configuration would be typical of a remote voice- transponder cabinet. In this configuration, one (1) MBR- MP would be used in the upper half of Model MLE-6 to mount the MXL modules; while the lower half would use two (2) Model MSR-1 rail kits to mount up to two (2) Model EL-410 amplifiers. Model MLE-6 is designed for surface or semi-flush mounting, and includes various knockouts for wire and conduit entry. The door supplied with the MLE-6 set has (3) cutouts for clear lenses, blank plates or grills- depending on the application. The door also contains two (2) key-locks, which are keyed the same. Various combinations of dead-front mounting plates are possible with the Model MLE-6 enclosure. A typical MXLV installation would have one (1) Model MKB-2 at the top, and two (2) MHD-3 dead-front plates in the middle — totaling 14VSM /VLM /VFM modules per plate - and one (1) or two (2) MHD-2 lower dead-front plates. MLE-6 MLE-6 (with MBR-MP &• (with door closed) (2) Amplifiers] MBR-3MP MLE-6 Optional Card Cage Mounting Plate Model MBR-3MP is an optional MXL I MXLV card-cage mounting plate, used exclusively in the Model MLE-6 enclosure. When installed in the Model MLE-6 back box, Model MBR-3MP adds the option of mounting up to an additional three (3) Model MOM or 0MM expansion card cages. MUK-$MI-' MDL-1 Clear Lens Model MDL-1 is a clear Plexiglas® lens that fits in either two (2) openings of the Model MME-3 enclosure door, or in one (1) of three (3) openings in the Model MLE-6 enclosure door. One (1) lens is included in the Model MDL-1 package. MOL-1 MDB-1 Sheet-Metal Blank Plate The Model MD13-1 is a sheet-metal blank plate that fits in either two (2) openings of the Model MME-3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One (1) blank plate is included in the Model MD13-1 package. MDB-1 MDG-1 Louvered Ventilation Plate Model MDG-1 is a louvered plate that mounts in either two (2) openings of the Model MME-3 enclosure door, or in one (1) of three (3) openings of the Model MLE-6 enclosure door. Model MDG-1 is required on MXLV systems to provide ventilation for the enclosures when using either Model EL-41 0 or Model ZAC-30 audio amplifiers. One (1) MDG-1 plate is included in the Model MDG-1 package. MDG-1 I I I I I I I I ri I I I I I I I I I I k SIEMENS Industry, Inc. Building Technologies Division MXL I MXLV Components - (cont.'d) MHD-1 Upper or Middle Dead Front Panel Model MHD-1 is a hinged sheet-metal panel that attaches to either Model MME-3 or MLE-6 enclosure back box. Model MHD-1 fits in either the upper or the middle section of the Model MME-3 back box - or either of the two (2) middle sections of the Model MLE-6 backbox. Model MHD-1 has an opening with a cover plate for the Model TSP-40 printer (when used), and attaches to the back boxes with screw fasteners. When in place, Model MHD-1 covers and protects modules and wiring; providing dead- front construction in that area. Each row can mount up to seven (7) modules, ttaling 14 modules for each Model MHD-3. Model MHD-3 attaches to the back boxes with screw fasteners. Model MHD-3 is hinged for easy access to the rear of the modules and inside of the enclosure. MHD-1 MHD-2 Lower Dead Front Panel Model MHD-2 is a hinged sheet-metal panel that attaches to either Model MME-3 or MLE-6 back boxes. Model MHD-2 mounts in the lower section of Model MME-3, and on the lower two (2) sections of the Model MLE-6 backbox. There are no openings for Model MHD-2, and it attaches to the enclosures with screw fasteners. When in place, Model MHD-2 covers and protects modules and wiring; provid- ing dead-front construction in that area. MHD-2 N1HD-3 Middle Dead Front Plate for Mounting Switch! LED! Fan Control Modules Model MHD-3 is a hinged sheet-metal panel that attaches to Model MME-3 or MLE-6 back boxes. Model MHD-3 fits in the middle or upper sections of the enclosures. Model MHD-3 has openings for two (2) rows of Model VSM-1 switch modules; Model VLM-1 LED- annunciator modules; Model VFM-1 fan-control modules, or Model VS13-1 blank plates. SIEMENS Industry, Inc. Building Technologies Division MHD-3 MHD-4 Middle Dead Front Plate for the Switch/LED/Fan Control Modules with Printer Cutout Model MHD-4 is a hinged sheet-metal panel that attaches to Model MME-3 or the MLE-6 back boxes. Model MHD-4 fits in the middle section of the Model MME-3 or the MLE-6 enclosures. Model MHD-4 has two (2) rows for mounting of Model VSM-1 switch modules; Model VLM-1 LED- annunciator modules; Model VFM-1 fan-control modules or Model VS13-1 blank modules. Each row has space to mount four (4) modules, totaling eight (8) modules for each Model MHD-4 panel. Model MHD-4 also has a cutout to display the Model TSP-40 internal thermal-strip printer. Model MHD-4 mounts to the back boxes with screw fasteners, and is hinged for easy access to the rear of the modules; as well as inside the enclosure. When installed, Model MHD-4 covers and protects modules and wiring, providing dead-front construction in that area. MHL)-4 VSB-1 Switch Blank Plate Model VSB-1 is a blank plate that covers one (1) opening in either Model MHD-3 or MHD-4 dead-front panels, and attaches to Model MHD-series panels with screw fasteners. I I MXL I MXLV Components - (cont.'d) Details for Ordering VSB-1 VSB-P Plastic Switch Blank Plate Model VSB-P is a plastic, blank-switch plate. Model VSB-P is a direct replacement for Model VS13-1. Six (6) plates are included in the Model VSB-P package. MSR-1 Rail Kit Model MSR-1 is a System 3TMtype rail kit that fits into either Model MME-3 or MLE-6 enclosures. Model MSR-1 comes with a U-bracket and a Z-bracket, and allows modules, such as: Model EL-41 0 amplifier; Model PS-35 power supply; Model BC-35 battery charger; Model M0I-7 I/O Interface; Model MID-16; Model MOD-1 6; Model PS-5A; Model SYS3-M PFO (for mounting the Model D2300CP fiber-optic interface modules or the CCU interface), or any other System 3-type module required to be mounted in the Model MME-3 or MLE-6 enclosures. When used in the Model MME-3 enclosure, three (3) Model MSR-1 rail kits can be installed to mount up to three (3) rows - for up to three (3) Model EL-41 0 amplifiers. When used in Model MLE-6, up to five (5) Model MSR-1 rail-kit rows can be installed, allowing up to five (5) Model EL-41 0 amplifiers. When Model MLE-6 enclosure is used with Model MBR-MP mounting plate for installation of MXL I MXLV equipment, up to two (2) MSR-1 rail-kit rows can also be installed in Model MLE-6 for mounting - either two (2) Model EL-410 amplifiers, or some complement of System 3-type mount modules. Model Number Part Number Description MXL/V Medium/Standard Enclosure MME-3 500-694209 (Backbox and door pkg.) Requires MBR.MP to mount MXL/V modules. Removeable module mounting plate MBR.MP 500.694210 needed for MME-3 and MLE.5 Enclosure. Allows mounting of up to (3)card cages (MOM/OMM) MME-3R 500-694892 Red version of MME-3 Enclosure MXL/V large Enclosure (8ackbox MLE-6 500-694530 and door pkg.) Requires MBR-MP to mount MXL/V modules. Card cage Expander Mounting Plate for use with MlE6 allows mounting MIIR.31MP 500.694532 of up to (3) additional cardcages (MOM/OMM) in the MIE.6 for a maximum total at (6) MOM or 0MM card cages in the MLE-6 MLE6R 599694893 Rod version of MLE.6 Enclosure Kit consisting of (1) MBR.MP. MIE-KIT 599694530 (1) MBR-3MP and (1) MLE- cables (without enclosures) MDL-i 500-692069 (1) Clear Lens MOB-i 500-692010 (1) Sheet Metal Blank MDGi 500-692213 (1) Louver Door Plate MHO-1 500-092011 (i) Dead Front Panel MIIO-2 500-092072 (II Dead Front Panel MHD-3 500-092073 Ill Dead Front Pane) MHO-4 500-092074 Ill Dead Front Panel VSB-1 500-092075 (1) Switch Blank VSB-P 500-648552 (6) Plastic Switch Blank MSR-1 500-092078 lii Rail Kit I I I I I L I I I I I I I U I LI I MSR-1 SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram 2,02V ' 2862 52.0' 39125 &3.fl 2125" MME-3 Back box VNMILE-6 (Shown In Inches) Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 (SIP) L6T 5E4 I Canada November 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905)799-9937 Supersedes sheet dated 11/06 URL: www.SBT.Sjemerts.com/FlS FAX: (905) 799-9858 1) On-board, diagnostic ground-fault LEDs Built-in Style 4 or Style 7 local module network 'RealTime' Clock ®UL 864 9th Edition Listed, ®ULC Listed 11 I I I I -Catalog Sheet SIEMENS Fire Safety &Security Products MXL / MXLV Fire Alarm Enclosures & Equipment Model: MMB-3 ARCHITECT AND ENGINEER SPECIFICATIONS MXL/ MXLV System main-control microprocessor Supports 6 Amps. (Model MPS-6) or 12 Amps. (Model MPS-12) power supply Two (2) isolated ALD Circuits: Class A- (Style 6)or Class B- (Style 4) No shielded wire required on ALD circuits Supports up to 50 total ALD circuits Monitor and Control up to 60 analog I intelligent input devices & 60 programmable device relays per ALD circuit Removable terminal blocks for all field connections On-board, 16 bit microprocessor Fully field programmable, via laptop PC System firmware capable to Flash memory upload • Product Overview The functions and controls for the MXL Control Panel are performed by the Model MMB-3 Main Control Board. The Model MMB-3 controls and monitors the following: input-device identity; network communications, and operator commands, which are each entered through the Model MKB annunciator! keyboard. All operations are supported by either the Model MPS-6 or Model MPS-12 power supply—eliminating the need for external power supplies. Model MMB-3 is a direct replacement of Models MMB-1 and MMB-2. Hence, Model MMB-3 is able to provide total backward compatibility. Specifications Model MMB-3 provides two (2) Analog Loop Driver (ALD) circuits. Each ALD loop can be configured as 'Class B' (Style 4) or 'Class A' (Style 6), and each can monitor and control up to 60 analog input devices and 60 programmable device relays. Style 4 or Style 6 ALD circuits are software- programmable, which eliminates the need for jumpers. Model MMB-3 is equipped with two (2) programmable and 'Class B' (Style Y) or 'Class A' (Style Z) notification- appliance circuits. Each circuit can activate up to 1.5 Amps of Siemens Industry, Inc. - Fire Safety audible and visual notification appliances. Model MMB-3 includes a built-in battery charger and transfer circuit. The charger is microprocessor-controlled, and incorporates a 'brownout' circuit that switches the MXL system to standby batteries during the reduction and ! or loss of the primary source AC to avoid inconsistent system operation and damage to the batteries. Upon command, Model MMB-3 is capable of displaying the 'RealTime' battery voltage, AC voltage, charge current, and other power data on the Model MKB alphanumeric display. Model MMB-3 also has a 24 VDC, 1 Amp. output that powers the Model CZM-1 B6 modules. Model MMB-3 is designed with a built-in mounting bracket. U I MXL/mxLv 5079 SIEMENS Industry, Inc. Building Technologies Division Details for Ordering Model Part Number Number Description MMB-3 500-648860 MXL Main control Board (with MBP-MP plate) Specifications - (cont.'d) Model MMB-3 mounts directly to the Model MBR-MP mounting plate for mounting in either the Model MME-3 or MME-6 backbox enclosure. Model MMB-3 can also be mounted in the Model MBR-2 or MBR-1 enclosures—with Model MBR-1 requiring additional mounting brackets. The on-board, 16-bit microprocessor -along with nonvolatile EPROM and Flash memory - allow the MXL system to be custom configured to meet a wide range of customer requirements. Model MMB-3 provides a port for connection to a laptop computer, allowing for off- line field programming. Complete system configuration can be easily uploaded, downloaded, and edited. Changes can be verified using Model CSG-M custom programming software with integrated CompareTM system software. Program options include (but are not limited to): Smoke-detector environmental compensation with two (2) maintenance-alert levels History logging Output-control (by event) check and change time-based control Detector sensitivity Alarm verification by device or zone 32-character, custom alphanumeric messages System operation passwords and NAC coding Application-specific detection using FirePrintTM System firmware is also resident in Flash memory, and can be upgraded by software upload - eliminating the need for upgrade chips. Model MMB-3 supports local, main-remote networking, via Style 4 or Style 7 wiring. This setup allows a single MXL system to be distributed throughout a facility. Model MMB-3 can then support up to 48 additional ALD circuits (50 total), and a total of 3,000 addressable input devices and programmable device relays. No additional module is required in the enclosure with Model MMB3 to use Style 7 local network wiring. Model MMB-3 is approved for operation over the temperature range of 32°F (0°C) and 120°F (49°C). Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 1501 L6T 5E4 I Canada FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 November 2009 Speredea sheet dated I2103 (Reel) I I SIEMENS Fire Safety 1 MKB=2 I MXL/MXLV Display/Keyboard ENGINEER AND ARCHITECT SPECIFICATIONS Full Command Keyboard 80 Character LCD Display Automatic Backlight High Resolution Supertwist LCD Programmable Function Keys Partial System Disable LED Power LED Alarm, Supervisory, Trouble And Security LED's Audibles Active/Silenced LED with Local Audible Menu Driven Operator Commands User Help Screens Printer Control Keys Display Control Keys I I I I I Tactile Membrane Switches With Audible Feedback Hinged Panel For Easy Access Listed and ULC Listed, CSFM, FM, NYMEA, City of Chicago Approved Description I I The MKB-2 is a display/keyboard module for use with the Siemens Building Technologies, Fire Safety Division MXL and MXLV systems.The MKB-2 is supplied on a hinged frame and mounts on the enclosure backbox. It provides a complete operator interface including an 80 character backlit supertwist LCD for display of all system information.The LCD shows events in sequential order and includes event type, device type and location, the time of the event and an indication if the event has been acknowledged. The MKB-2 also provides a set of keypads used to execute system commands such as Acknowledge, Silence, Reset as well as disarming of devices for maintenance and generation of system diagnostic reports. From the keypad the operator is able to change the sensitivity setting of smoke detectors, check device voltages, obtain system power reports, disarm input and output devices and manually toggle remote and local relays. All commands are menu driven and a Help key allows the operator to get further explanation of the command structure. Operator actions are prompted so training is kept to a minimum. The MKB-2 also provides a set of 12 programmable functions keys.The keys can be configured to activate functions such as Drill, Fan Shutdown, Door Release, etc. LEDs on the MKB-2 in conjunction with a local audible, indicate active conditions such as Alarm, Supervisory, Trouble and Security.The LEDs flash and the audible sounds until events are acknowledged. Additional LEDs indicate Audibles Silenced, Power On and Partial System Disable.The Partial System Disable LED illuminates whenever an input or output device is disarmed. Display control keys allow the operator to Hold or Ad- vance the scrolling display and view additional active events. Multiple MKB-2s can be used in the system each providing full control of the MXL system. Up to four MKB-2s can operate in a fully supervised mode, each with independent printer driver capability (using a PIM-1). The hinged panel allows easy access to the rear of the MKB-2 and the other modules in the rear of the enclosure backbox.The MKB-2 is covered by a clear lens (MDL-1) as a part of the MDR-2 lockable door. CATALOG NUMBER 5026 I I I I I I I When used in MXLV applications, the MKB-2 has removable plates on either side of the keyboard to allow mounting of the MMM-1 (Microphone Master Module) and theTMM-i (Telephone Master Module). The MKB-2 also has mounting studs available for the ACM-1 in MXLV applications. This equipment is approved for operation over the temperature range of 0°C to 49°C. Ordering Information Model Number Description Part Number MKB-2 Display/Keyboard 500-892077 PIM-) Printef Interface 500-691324 Refer to Installation Instructions P/N 315-092087 MK13-2 Controls and Indicators I i 00,M 01. 1Q00 PTIQ0IROQ0CS 01VQM MOt 1!!1 0 ALARM 0 POWER [ EI AUDIBLES PARTIAL 0 SILENCED SYSTEM o SUPERVISORY I ' W-KII 0 TROUBLE LJLJ I EIi 0 SECURITY ALT ALT IItirEII III1EiIIwEII AU E.1111 Lr IIHEflIcII FIGURE 1 MKB-2 Panel Mounting Diagram FIGURE 2 Installing the MKB-2Annunciator/Keypad Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 1/04 Brampton, Ontario Tel: (973) 593-2600 Siemens Building Technologies FAX: 19731 593-6670 Fire Safety Website: www.sbt.siemens.com/fis EM SFS-IG Printed in U.S.A. Canada L6T 5E4 Tel: (905) 799-9937 January 2004 FAX: (905) 799-9858 Sopetsedes sheet doted 5/02 5129 5230 5128 SIEMENS Fire Safety Silent Knight 5128 ,and 5129 FourChannel Digital Communicator, ENGINEER AND ARCHITECT SPECIFICATIONS 864 Listed. Meets NFPA 72 Chapter 4, for Central Station/Remote Station Monitoring DL Listed as a Slave Communicator for Connection to System 3TM SXL-EX°, PXL', and MXL Fire Alarm Control Panels Four Fully Supervised Input Channels Dual Phone Line Interface and Line Fault Monitoring Automatic 24 HourTest Reports in Eight (8) Standard Communication Formats Local Keypad Programmer/Annunciator (5230) Remote Programming (Up/Down Loading) Relay Output for System Alarm or Trouble Conditions Compact Size Allows Mounting in Most Control Cabinets, also Available in Separate Enclosure (Model 5129) I I I I I I Ii I I I Description & Feature Siemens BuildingTechnologies, Fire Safety Division offers the Silent Knight Models 5128 and 5129 four channel, dual line digital communicators. These "slave" communicators are designed to monitor UL listed fire alarm control panels.The model 5128 is specifically designed and listed to be mounted in the System 3TM SXL-EX, MXL and PXL system enclosures. Power from these fire alarm controls drive the 5128. Programming and troubleshooting time is minimized by user friendly English language messages available with both the Model 5230 local programmer and PC based remote downloading software, Model 5561. Channel Inputs Four supervised, or unsupervised, channel inputs can be configured as either voltage inputs, active high or low inputs, or contact closure inputs. The System 3TM using the CSI-35 module, provides a combination of contact closures and active high voltage input to activate the 5128/29. The SXL-EX, MXL and PXL use a contact closure for each channel. The preset channels are programmed as follows: Channel 1 Alarm (Fire) Channel 2 Trouble (Fire) Channel 3 Sprinkler Supervisory Channel 4 Alarm (Undefined) Phone Line Monitors Two phone line circuits detect phone line faults by monitoring their voltages. Reporting of a fault as a trouble condition is delayed by 40-90 seconds; if the condition persists, an audible trouble in the communicator will sound and the trouble reported to the central station. To ensure phone line accessibility the 5128 and 5129 are equipped with line seizure. Test Functions After power-up, the 5128 and 5129 self-test system status. A watchdog circuit on the microprocessor resets the communicator if a failure occurs. Additionally, a 24-hour auto test can be programmed to a central station at a precise time.The installer can also initiate a manual test using the Model 5230 programmer. I I I I I I I CATALOG NUMBER 4000 I Programming/Downloading The Model 5230 LCD keypad programmer can be temporarily connected to program or troubleshoot the communicator on site. English language messages assist in entering data, changing the 24-hour test time and describing conditions currently in effect. A ring detector on the 5128 and 5129 allows one call downloading when used with optional remote programming software and modem Model 5561. AC Monitoring All Fire Safety Fire Alarm Control Panels, as well as the Model 5128 and 5129 communicators, can be programmed to delay transmission of this signal to a central station as required by Underwriters' Laboratories. The System 3 T transmits this signal via an active high output from the Model CSI-35 central station interface. Technical Specification Electrical: Input - 24VDC from UL listed fire control panel. Maximum DC Load: Standby - 84mA Alarm - 154mA AC Monitoring Input: AC trouble output from System 3 T CSI-35 module Relay Output: Form Cat 1A24VDC/24 VAC for Alarm orTrouble Indicator Lights: Green LED Power On; Red LED Phone Line Trouble;Yellow LED Input Fault and SystemTrouble Connection: Screw terminals for phone line and relay outputs. Color coded flying leads for control panel inputs Reporting Formats: Communicates via SK 3/1; 5K4/2; SESCOA3/1; SK FSK (4/2); Radionics BFSK 14 and 23; SIA 8/S1A20 formats Telephone Requirements: FCC registration No. AC6USA-75160-AL-E Ringer Equivalence - 0.913 Type of Jack - RJ31X (two required) Approvals: UL 864 listed, NYMEA and CSFM approved for SXL-EX, SXL, MXL, PXL, FireFinder XLS and System 3 T Mechanical Specifications Model 5128 Dimensions: 83/4"Hx4"Wx11/4"D Enclosure: Vinyl/Acrylic meets U L94V0 Color: Black Weight: 2 Lb. Model 5129 Dimensions: 10/8" H x 101 /9"W x 3" D Enclosure: Sheet Metal Cabinet Color: Red Weight: 6 Lb. Accessories.' Model 5230 Programmer/Annunciator with harness 5561 Downloading software/modem kit 5128 Telephone interface kit - includes RJ-31X block and cord, 3 ft., with spade connectors Mounting Suggestions System 3 - mount in rear of enclosure or on mounting rails SXL-EXIPXL -mount on inside front door below viewing window, or left side backbox MXL - mount on inside of MHD-2 or MSR-1 rail kit Ordering Information Model Number Description Part Number 5128 Silent Knight 4-Channel, Dual Line Digital Fire Communicator - Internal 500-693213 5129 Silent Knight 4-Channel, Dual Line Digital Fire Communicator . Remote 500-693214 5230 Programmer/Annunciator with Harness 500-693215 5561 Downloading Software/Modern Kit 500-693216 TlK-512 Telephone Interface Kit 500-293218 CSI-35 System 3 Central Station Interface Module 500-892318 Refer to Installation Instructions P/N 315-093223 Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (973) 593-6670 Website: www.sbt.siemens.com/fis 1/04 SFSG Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario Canada L61 5E4 Tel: (905) 799-9937 FAX: (905) 799-9858 January 2004 Supe,sedes sheet dated 9102 RCC-2 (Door Closed) (Door Open) I L SIEMENS Fire Safety I RCC=2 Remote Control Center I RSE=1 Remote Serial Interface I ENGINEER AND ARCHITECT SPECIFICATIONS Remote MXL Display and Control 80 Character LCD Display Auto Backlight Flush Mount Option Supertwist High Resolution Display Full Command Keypad MXL Network Interface (Style 4 or Style 7) Metal Enclosure with Keylock Door Restricts Keypad Access Optional Printer/Peripheral Interface (PIM-1) Supervised I • Listed I I I I I Description The Siemens Fire Safety Model RCC-2 Remote Control Center annunciates MXL and MXL-Q system status. The product includes an 80-character LCD display and system status LED's. The RCC-2 includes system acknowledge, silence and reset functions. The RCC, plus the RSE-1, provide for mounting and control of the PIM-1 printer interface module. The RCF-1 is a flush trim ring for each of the controls. Features The RCC-2 annunciates all events that occur within an MXL system. The LCD display includes scroll keys that allow the operator to view sequential events. In this manner the display reports each event by its type, specific device, location and time. The RCC-2 key switches allow individual or global acknowledge of events by type, system silence, resound and reset. All switches are protected by a clear cover and se- cured by a lockset that matches the MXL system. The unit enclosure is black. The RCC/RSE products connect directly to the MXL system network in style 4 or style 7 wiring. Multiple units can be connected to any system for annunciation at various locations throughout a facility. Up to three units can be supervised with additional unsupervised controls. Power is provided by any listed 24 Volt supply. All units include a mounting location and control of the PIM-1 printer driver. Therefore, any of them can operate a printer, video display terminal, alphanumeric pager interface or remote diagnostics module. Each of these system options is available from Siemens Fire Safety. CATALOG NUMBER 5073 I n I U I I I Ordering Information Model Description Part Number RCC2 Remote Control Center with System Control Functions and Sequential Event Display 500-699160 RSE-1 Remote Serial Interface Enclosure 500-699162 RCF-1 I Remote Control Flush Trim 500-699163 PIM-1 Power Interference Module 500-691324 T-45 Siemens Key 315-221182 Refer to Installation Instructions 315-099160 Approvals The RCC series of annunciators and the RSE-1 are listed by Underwriters Laboratories as compatible with MXL-IQ, MXL and MXLV systems for indoor applications. Dimensional Data 5 in RCC-2, RSE-1 Dimensions RCC-2/RSE-1 BACKBOX AL) KBOX RCC-2 Exploded View RSE-1 Exploded View Fire Safety Fire Safety 8 Fernwood Road 2 Kenview, Boulevard Florham Park, NJ 07932 9/01 Brampton, Ontario Siemens Building Technologies Tel: (973) 593-2600 FAX: (973) 593-6670 Fire Safety Website: www.cerbpyro.com 10M SFS-IG Printed in U.S.A. Canada L6T 5E4 Tel: 19051 799-9937 FAX: (905) 799-9858 September 2001 New Issue SIEMENS Fire Safety PAD 3 Auxiliary Power Supply - Notification Appliance Extender ENGINEER AND ARCHITECT SPECIFICATIONS I I I I 6 amps of Notification Appliance Power Advanced Microprocessor Control 24VDC Output Voltage Four Power-Limited Notification Outputs Strobe Synchronization Option Built In Synchronized ANSI Temporal Pattern Class 'A Selectable Ground Fault Detection Battery Supervision 3 Amp Auxiliary Power Output Trouble Contact for Monitoring Multiple Module Mounting in System 3 Enclosures Multiple Modules Share Battery Set UL, ULC Listed, CSFM, NYMEA and FM Approved I I I I I I I Introduction The Model PAD-3 (PAD-3C for Canada) is a notification appliance circuit expander with a built-in auxiliary power output. It is designed for use with Siemens BuildingTechnologies, Fire Safety Division fire alarm control panels. This power source is designed to provide the extra power required in buildings conforming to the Americans with Disabilities Act. Features The PAD-3 provides 6 amps of 24 VDC power for multiple uses. All 6 amps can be directed to 4 Notifi- cation Appliance Circuits (NAC s). Each is rated at 3 amps and is power limited. Either 1 or 2 inputs can control the four outputs. These outputs are compatible with all Fire Safety 24VDC notification appliances. . The PAD-3 can be configured so that the inputs can be programmed as steady outputs, ANSI temporal outputs, or synchronized strobe outputs. It can also be programmed so that one input will silence U-MHU- Series horn/strobe horns while the strobes remain on using one set of wires. The PAD-3 also offers a 3 amp auxiliary output for driving other portions of your fire alarm system such as door holders.This 24VDC filtered output is power limited. When using this output, the total power available from the PAD-3 will not exceed 6 amps. A trouble contact is provided for monitoring the PAD-3 with a fire alarm panel through the input. It also has a Form C dry contact for trouble monitoring. Therefore, the user has the option of connecting it to a conven- tional fire alarm panel's existing notification circuit, or controlling it with aTRI Series device on intelligent fire systems. The PAD-3 offers battery supervision and management as is required of fire alarm system components. Ground faults are transmitted as are any other trouble conditions. Trouble conditions not only change the state of the trouble contact in the unit, but they also break the notification circuit input to create a trouble signal in the fire alarm control unit. CATALOG NUMBER 3362 I I I I I I I I This product is packaged in its own sheet metal enclosure with enough space to house the 7 amp-hour battery set required for back-up.The enclosure comes in black or red. System 3 enclosures may also be used to house multiple PAD-3 modules in a single enclosure. Two modules are capable of sharing the same battery set when mounted in the same enclosure. Options One or both PAD-3 signal inputs control the notification outputs, depending on the specific configuration setup Possible configurations for the PAD-3 are: For These Control These Option: Inputs: Outputs: As: 1 Input 1 All Outputs Class 8 Circuits 2 Input 1 All Outputs Class 8 Circuits Input 2* Silences horns on 1 3 Input 1 Outputs 1 and 2 Class 8 Circuits Input 2 Outputs 3 and 4 Class B Circuits 4 Input 1 Output 1 Class 8 Circuits Input 2 Outputs 2,3 and 4 Class B Circuits 5 Input 1 Outputs 1-2,3 and 4 Class A Circuit Pairs 6 Input 1 Outputs 1-2,3 and 4 Class A Circuit Pairs Input 2* Silences horns on 1 7 Input 1 Outputs 1 and 2 Class A Circuit Pairs Input 2 Outputs 3 and 4 Class A Circuit Pairs 8 Input 1 Outputs 1-2 Class A Circuit Pairs Input 2 Outputs 3 and 4 Class B Circuits *When used with U-MHU-Series horn/strobe units Supervision The Model PAD-3 supervises a variety of functions including: Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the PAD-3 creates a trouble condition on the fire control signal circuits to which it is connected. It still maintains the ability to be activated by the fire control. In addition, the PAD-3 provides a Form 'C' trouble relay output as an alterna- tive to using the notification circuit trouble. Electrical Specifications AC Input: 120VAC @2.5 amps Output: 24VDC @ 6 amps Auxiliary Power Circuit: 1 Notification Circuits: 4 Output Configuration: 2 Class A or 4 Class B or 1 Class A & 2 Class B Amps per Output Circuit: 3.0 Notification Circuit Outputs: 24VDC at 3.0 amps each, 24K ohm EOL resistor required on each Class B circuit No. of Inputs: 2 Input Configuration: 2 Class B or 2 Class A Input Voltage Range: 9-32VDC Maximum Input Current: 0.006 Amps Battery Charging Capacity: 15.OA.H Trouble contact rating: 2.5A @250 VAC, 30VDC Ambient Temperature: 32°F to 120°F Mechanical Specifications Single Module Enclosure Model EN-PAD Dimensions: 12'Wx16"Hx3'D Color: Black Indicator Lights AC Power On: Green BatteryTrouble: Yellow Ground Fault: Yellow AuxiliaryTrouble: Yellow Output 1 Trouble: Yellow Output 2Trouble: Yellow Ordering Information Model Description Part Number PAO-3 Aux. power supply w/black enclosure 599-699189 PAD-3R Aux. power supply w/red enclosure 599-699190 PAD-3-MB Aux. power supply - main board only 500-699080 EN-PAD Black enclosure for PAD-3 310-099073 EN-PADR Red enclosure for PAO-3 310-099150 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 8/05 Brampton, Ontario Tel: (973) 593-2600 Siemens Building Technologies FAX: (973) 593-6670 10M SFS-lG Canada LIST 5E4 Tel: (905) 799-9937 Fire Safety Website: www.siemens.com/fis Printed in U.S.A. FAX: (905) 799-9858 August 2005 Supersedes sheet doted 9/03 need for cumbersome, unreliable mechanical program- ming methods and reduces installation and service costs by electronically programming and testing the detector prior to installation. The FP-11 fire detector is compatible with the MXL family of control panels including the MXL, MXL-IQ, and MXLV. The FP-11 detector is Underwriters Laboratories and Underwriters Laboratories of Canada Listed. Description The FP-11 is a plug-in, two-wire, multi-sensor detector with both photoelectric and thermal inputs and is compatible with the MXL family of control panel systems. Each detector consists of a dust resistant, field cleanable photo chamber, a solid state SIEMENS Fire Safety FP-11 FirePrintTM Detector Intelligent Fire Detector for MXL, MXL-IQ, and MXLV Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS Most Sophisticated "Detector Intelligence" available today Multi-Criteria fire detection for the price of a photoelectric detector FirePrintTMTechnology to discriminate between deceptive phenomena and an actual fire Easily programmed to match specific hazard profiles from the control panel Pre-Alarm reporting based on fire profile selected Remote sensitivity measurement capability System logic activation based on any of three inputs from detector (smoke, heat or neural network) Field cleanable chamber with replaceable chamber parts available Multi-color detector status LED Two-wire operation -. Compatible with Model DPU or FPl-32 field programmer/tester Supports EnviroLlNK software based automatic environmental compensation Backward compatible with older MXL systems (Rev.2 and above) - Optional fully programmable relay base, audible base, and -duct housing UL Listed, ULC Listed, CSFM, FM, NYMEA Ui Approved Introduction The FP-11 Intelligent Fire DetectOr provides the life safetyindustry with the most highly evolved detection system available today. The FP-11 utilizes advanced detection technology that allows the detector to distinguish nonthreatening deceptive phenomena, such as cigarette smoke, from actual fire hazards, while optimizing detection for the area in which it is in- stalled. No other detection system available today offers a higher level of protection or nuisance alarm- immunity. The FP-11 uses state-of-the-art microprocessor circuitry with error check, detector selfdiagnostics and supervision programs. The FP-ii intelligent fire detector is compatible with the Siemens Building Technologies, Fire Safety Divi- sion, Model DPU or FPI-32 field programmer/tester, which is a compact, portable, menu-driven accessory for electronically programming and testing detectors, easily and reliably. The DPU or F P1-32 eliminates the CATALOG NUMBER 6175 non-mechanical thermal sensor, microprocessor based electronics with a low-profile plastic cover and base. The FP-11 utilizes state-of-the-art ASIC and surface mount technology for maximum reliability. Every FP-11 fire detector is shipped with a protective dust cover. The FP-11 fire detector utilizes an infrared light emitting diode (IRLED), and light sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non-smoke airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles and is received by the photodiode. The FP-11 also utilizes a modern, accurate, shock- resistant thermistor to sense temperature changes. The "on-board" FirePrint technology allows the detector to gather smoke and thermal data, and to analyze this information in the detector's "neural network' By comparing data received with the common characteristics of fires, or fire fingerprints, the FP-11 can compare these "Fire Prints" to those of deceptive phenomena that cause other detectors to alarm. The advanced FirePrint technology allows the FP-11 to accurately determine a true fire hazard from a nonthreatening deceptive phenomena WITHOUT needing to use alarm delaying verification and confir- mation techniques, which can increase the probability of losses due to fire. The FP-11 provides the highest level of detector intelligence available today with a detector/control panel link that allows the user to program the detector for the specific hazard profile Detectors are optimized by selecting one of the following applications: Office/Retail Lobby Computer Room Dormitory Healthcare Parking Garage Utility/Transformer Room Hostile Environment Precious Storage Air Duct Warehouse/Light Manufacturing The software does the rest; no guessing on detector sensitivities or alarm verification; the control panel programs the FP-11 detector for the protected area without hassle and without confirmation delays. Once optimized for the hazards in the protected area, the FP-11 provides the best detection you can buy. Should the operator or installer forget to program the detector, the FP-11 will revert to a default setting that allows it to operate as a standard photoelectric or photothermal detector. The FP-11s FirePrint technology monitors input from both the photo chamber and the thermal sensor, evaluating this information with sophisticated mathematical formulas, or algorithms, comparing this input to characteristics of both threatening fires and deceptive phenomena that would "fool" any ordinary detector. This technology was developed over years of research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire research centers. The results of this research are the mathematical models that form the algorithms used in FirePrint. No other fire detector has this level of intelligence or this amount of research and develop- ment supporting it's design. The microprocessor's software can identify and disregard false input caused by radio frequency (RFl) and electromagnetic (EMI) interference, and validates all trouble conditions before annunciating or reporting to the control panel. The FP-11 detector's microproces- sor uses an integral EEPROM to store the detector's address and other critical operating parameters which include the assigned program values for alarm and trouble thresholds. Communications within the detector itself and between the FP-11 and the control panel, or with the FPl-32 field programmer/tester, are supervised and safeguarded against disruption by reliable, microprocessor based error checking routines. Additionally, the microprocessor supervises all EEPROM memory locations and provides a high degree of EEPROM failure fault tolerance. In MXL(V) applications, the FP-11 determines its operating status to be normal, in alarm, or in trouble depending on the difference between the alarm threshold values stored in the detector's memory and the detector's latest analog measurement. The detector then communicates changes in its status to the control panel. In addition, the MXL(V) control panel will sample the value of the FP-11's analog signal over a period of time in order to determine if those values indicate exces- sive buildup in the photo chamber; if so, the MXL(V) will indicate that the particular detector requires maintenance. The FP-11 is listed as a self-testing device. The FP-11's visible light emitting diode (LED) flashes green every 4 seconds to indicate it is communicating with the control panel and that it has passed its internal self- test. Should the detector sense a fault or failure within its systems, the LED will flash amber and the detector will transmit that information to the control panel. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the MXL panel indicating the status and settings assigned to each individual detector. When the FP-11 moves to the alarm mode, it will flash amber and transmit that information to the control panel. When the MXL(V) confirms the detectors condition, the panel will instruct the FP-11 to flash red and to continue flashing until the system is reset at the control panel. At that same time, any user defined system alarm functions programmed into the system are activated. Each FP-11 detector can operate one remote alarm indicator, one auxiliary relay, or one audible base. Detector sensitivity, calibration, and identification are dynamically supervised by the control panel. Detector sensitivity and pre-alarm levels are a function of the application chosen at the control panel and are controlled by the panel. If an alternate, non-FirePrint mode is selected, then the sensitivity can be changed from the control panel. The DPU or F P1-32 Program/Test accessory is used to program and verify the detector's address. The technician selects the accessory's program mode to enter the desired address. The DPU or FPl-32 auto- matically sets and verifies the address and tests the detector. It also allows the user to change the device ID from that of an FP-11 to an older detector ID such as an lLP-i, lLPT-1, lLP-2, ID-60P or lD-60PT to allow for easy replacement of older detectors without the need of reprogramming the control panel. The FPI-32 operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment almost anywhere. When in the test mode, the DPU or FPl-32 will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. All FP-11 detectors can be cleaned in the field, when required, by simply removing the detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush, or replacing the labyrinth and bug screen included in the detector maintenance kit, model DMK-ii. The FP-11 uses the low profile surface mounting base, model DB-11. This base mounts on a 4-inch octagon, square, or a single gang electrical box. The base utilizes screw clamp contacts for electrical connections and self-wiping contacts for increased reliability. The base can be used with the optional LK-11 detector locking kit which contains 50 detector locks and an installation tool, to prevent unauthorized removal of the detector head. The DB-11 base has integral decora- tive plugs to cover the outer mounting screw holes. The FP-ii is electrically compatible with existing MXL detector accessories including relays, remote lamps, duct housings, and audible bases. With duct housings, a base adapter and new detector housing cover are required (order AD-li UK upgrade kit). To use existing DB-3S base or audible base, the FP-11 requires a DB- ADPT base adapter. All FP-11 detectors are approved for operation within the UL specified temperature range of 32 to 100 degrees F (0 to 38 degrees Q. Application Data Installation of the FP-11 series of fire detectors requires a two-wire circuit of 18 AWG (minimum) thermoplastic fixture wire enclosed in conduit, or 18 AWG limited energy, shielded cable without conduit, if permitted by local codes. Field wiring should conform to local and National Electric Codes and the control panel wiring specifications. "T-tapping" is permitted only for Style 4 (Class B) wiring. FP-11 fire detectors can be applied within the maxi- mum 30 foot center spacing (900 sq. ft. areas) as referenced in NFPA 72. This applications guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens Building Technologies, Fire Safety Division authorized sales outlet whenever you need assistance applying FirePrint in unusual applications. Be sure to follow NFPA guidelines, U L/U LC approved installation instructions, which are included with every detector, and local codes as for all fire protection equipment. Dimensions I I I I I I I I I I I I I I I I The FP-11 fire detector may be installed on the same initiating circuit with IL or ID series detectors (Photo- electric, thermal, or ionization), MSI series manual I stations, TRI series interfaces, ICP output control devices, or CZM series of addressable, conventional zone modules. I Technical Specifications Current Requirements: Normal 750 pa Alarm 750 pa Operating Temperature: +32°F (0°C) to 100°F (38°C) per UL 268/268A Humidity: 0-93% Relative Humidity Non-Condensing Ordering Information Model Description Part Number FP-11 Addressable FirePrint Fire Detector 500-095112 OBil Detector Mounting Base for Series 11 500-094151 DB-11E Detector Base (Small) 500-094151E AD2-P Air Duct Housing for use with FP-11, HFP-ii, HFPO-11, PE-11 500-649706 AD2-XHR Air Duct Housing for use with FP-11, HFP-11, HFPO-11 with relay 500-649708 ADBX-11 Audible Base 500-096181 DB-X11RS Relay Base for Series 11 Intelligent Detectors 500-096125 RU-1 Remote (red) alarm indicator- 4 octagon box mount 500-390613 RU-2 Remote (red) alarm indicator- single gang box mount 500-390614 LK-11 Base Locking Kit for Series 11 detectors 500-695350 DMK-ii Series ii Maint Kit (replacement labyrinth and bug bug screen) 500-695338 DB-ADPT Base Adapter to OB-35 Base 500-094187 In Canada Order. FP-11C Addressable FirePrint Fire Detector (ULC( 500-095112C DB-11C Detector Mounting Base for Series il(ULC) 500-095687 AD-11 PC Air Duct Housing )IJLC( 500-095984 D8-X11 RSC Relay Base for Series 11 Intelligent Detectors (ULC) 500-096125C ADBX-11C Audible Base for Series 11 Intelligent Detector (ULC( 500-096181C Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (973) 593-6670 Website: www.sbt.siemens.com/fis Fire Safety 2 Kenview Boulevard 5/06 Brampton, Ontario 1OM Canada L6T 564 SFS-IG Tel: (905) 799-9937 May 2006 Printed in U.S.A. FAX: (905) 799-9858 Supetsedes sheet doted 6/03 Catalog Sheet SIEMENS Fire Safety & Security Products MXL, MXL-IQ -and MXLV' Control Panels Intelligent Thermal Detector Model FPT-11 ARCHITECT AND ENGINEER SPECIFICATIONS Microprocessor-based design Rate compensated I F I Innovative technology provides high-speed; fault-tolerant System I Detector communications MUlti-color detector status LED Optional fully-programmable relay and audible bases Two-wire operation Backward compatible with older MXL systems ' (Rev 2and Above) Compatible with DPU or FPI-32 field programmer'! tester ® UL and 0 ULC Listed; FM, CSFM & NYMEA Approved Product Overview I F I I I I I I The FPT-1 1 Intelligent Thermal Detector, which operates with the MXL family of control panels: MXL, MXL-IQ and MXLV, provides an advanced method of detection / address programming and supervision —combined with sophisticated control-panel communication. The FPT-1 1 detector uses a state-of-the-art thermistor that provides up to 135°F (57.2°C) rate-compensated temperature. The FPT-1 1 Intelligent Thermal Detector is compatible with the DPU and FPl-32 Field Programmer / Testers. These testers are compact, portable and menu-driven accessories that make programming and testing detectors faster, easier and more reliable than other methods. The FPI-32 Field Programmer/ Testers eliminate the need for cumbersome, unreliable mechanical programming methods, and reduce installation and service costs, via electronically programming addresses and functionally testing the FPT-11's performance before the detector is installed. The FPT-1 1 Intelligent Thermal Detector is Underwriters' Laboratory listed' and Underwriters' Laboratory of Canada listed. Specifications The FPT-1 1 is a plug-in, two-wire thermal detector, compatible with the MXL family of control panels. Each FPT-1 1 has microcomputer-chip technology and highly stable, solid-state electronic circuitry. TheFPT-1 1 utilizes a modern, accurate and shock- resistant thermistor to sense temperature, changes. This electronic sensing method virtually eliminates thermal lag associated with mechanical-temperature sensing devices, and provides almost instantaneous temperature information to the control panel. I I I F 'I MXL Control Panels 6176 Building Technologies I Fire Safety & Security Products Specifications - (continued) The FPT-1 1 is a 1 35°F (57.2°C) rate-compensated detector. The microprocessor for the FPT-1 1 detector uses an integral EEPROM to store the detector's address. Communications within the detector, as well as between the FPT-1 1 and the control panel (or with the FPl-32 field programmer I tester) are supervised and safeguarded against disruption by reliable microprocessor-based error-checking routines. Additionally, the microprocessor supervises all EEPROM memory locations, and provides a high degree of EEPROM failure fault tolerance. The FPT-1 us listed as a self-testing device. The visible Light-Emitting Diode (LED) from the FPT-1 1 flashes green every four seconds to indicate it is communicating with the control panel and to notify it has passed its internal self-test. Should the detector sense a fault or failure within its systems, the LED will flash amber, and the detector will transmit that information to the control panel. A quick, visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the MXL panel indicating the status and settings assigned to each individual detector. When the FPT-1 1 moves to the 'Alarm' mode, the FPT- 11 will flash amber and transmit that data to the control panel. When the MXL (V) confirms the current condition of the FPT-1 1, the panel will instruct the FPT- 11 detector to flash 'red' until the system is reset at the control panel. At that same time, any user-defined, system-alarm functions programmed into the MXL System are activated. Each FPT-1 1 detector can operate (1) remote alarm indicator, (1) auxiliary relay, or (1) audible base, and only (1) accessory per detector. A DPU or FPl-32 programmer I tester is used to program and verify the address for the FPT-1 1. The user selects the 'Program' mode to enter the desired address. The programmer I tester then automatically sets and verifies the address as well as test the detector. The programmer I tester contains rechargeable batteries, in order for the address of the FPT-1 1 to be programmed by the user from the most convenient location. The user can also separately test the FPT-1 1 detector for functionality. When the user selects the 'Test' Mode, a series of tests are automatically conducted, and the user is informed whether the FPT-1 1 detector has passed or failed. The FPT-1 1 detector is compatible on the same MXL- initiating circuit with other IL Series, FP Series or ID-60 Series addressable ionization, photoelectric, or thermal detectors, MSI addressable manual stations, TRI Series addressable interfaces, or CZM Series addressable conventional zone modules. Building Technologies Fire Safety & Security Products Each FPT-1 1 thermal detector is capable of operating one "X" or "I" Series remote alarm indicator or auxiliary relay or audible base. The FPT-1 1 detectors use a surface mounting base, Model DB-1 1, which mounts on a 4-inch octagonal, square or single gang electrical box. Relay base Model DB-X1 1 RS mounts to a 4-inch square deep electrical box. Audible base Model ADBX- 11 also mounts to a 4-inch square deep electrical box. The DB-1 1, and the DB-X1 1 RS and ADBX-1 1 use screw- clamp terminals for all electrical connections and self- wiping contacts for reliability. The bases also contain a provision for an optional concealed locking mechanism to prevent unauthorized removal of the detector head, Model LK-1 1. Application Data The MXL uses ALD loop circuits with each circuit capable of supporting up to (60) FPT-1 1 intelligent detectors. The detector, or group of detectors, require a two-wire circuit of minimum 18 AWG thermoplastic fixture wire enclosed in conduit, or minimum 18 AWG limited energy, shielded cable without conduit if permitted by local building codes. Wiring should conform to local and National Electrical Codes, and to the control panel's wiring specifications. T-tapping is permitted only for Style 4 (Class B) wiring. Locate the FPT-1 1 on the ceiling, at least 4 inches from the side walls. For an ideal, smooth ceiling condition, place the detectors at a maximum center spacing of 50 feet (2,500 square feet), 25 feet from side walls or room partitions. For FM-approved installations, the FPT-1 1 has a RTI rating of 'QUICK.' Use a maximum center spacing of 20 feet (400 square feet), 10 feet from side walls or room partitions. Actual job conditions and sound engineering judgment must determine detector spacing. Consider environmental factors including ambient temperature fluctuation, and the nature of the fire hazard. Room or area configuration and ceiling type (sloped or flat, smooth or beamed) also dictates placement. Should questions arise regarding detector placement, follow the drawings provided and I or approved by Siemens Building Technologies - Fire Safety Division or by its authorized distributors. Technical Data Current Requirements: Normal 750 pa Alarm 750 pa Operating Temperatures: +32°F (0°C) to 100° F (38°C) Humidity: 0-93% Relative Humidity Non-condensing Mountina Diaaram Details for Ordering Model No. Part No. Description FPT:11 -' 500-095918 Addressable Thermal fire Detector 081 500-094151 Detector Mounting Base for Series 11 DO-11E 500-094151E Small 4.5 inch Diameter Detector Base 08-X1IRS 500-096125 Relay Base for Series 11 Intelligent Detectors ADBX-ll 500-096181 Audible Base for Series Ii Intelligent Detector RU-i 500-390673 Remote (red) alarm indicator-octagon box mount RLl-2 500-695350 Remote (red) alarm indicator-single gang box mount LK-11 500-695350 Base locking Kit for Series 11 DB-ADPT 500-094187 Base Adapter to D8-3S Base In Canada Order: Model No. Part No. Description FPI tic 500-095918C Addressable Thermal Fire Detector (ULCI DB-HC 500-095687 Detector Mounting Base for Series i1lULC) 08-X11RSC 500-096125C Relay Base for Series Ii Intelligent Detectors (ULC) AOBX-11C 500-096181C Audible Base for Series 11 Intelligent Detector (1JLCl I I I I I I I I I I I I I I I Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard Building Technologies Florham Park, NJ 07932 Brampton, Ontario J 2009 Fire Safety & Security Products Tel: (973) 593-2600 srs L6T 5E4 / Canada FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 Supd ht dated 12/03 (Rev.l) URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 I I I LI The MSI-10B and 20B manual fire alarm boxes operate with the MXL, IXL/lCON-1 and XL3 control panels. The manual fire alarm box's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Fire Safety's innovative technology also allows all MSI Series Intelligent manual fire alarm boxes to be pro- grammed by using the Model DPU or F P1-32 Program- mer/Tester. The Programmer/Tester is a compact, portable, menu driven accessory which makes pro- gramming and testing a manual fire alarm box device faster, easier and more dependable than previous methods. The DPU or FPI-32 eliminates the need for the device's mechanical addressing mechanisms, such as program jumpers, dipswitches or rotary dials because the Programmer/Tester electronically sets the manual fire alarm box's address into its microcomputer chip, nonvolatile memory. Vibration, corrosion and CATALOG NUMBER 6187 Replaces Catalog No. 6162 I I I I I SIEMENS-,.. Intelligent Initiating Devices Manual Fire Alarm Boxes MSI:10B and MSI-20B Intelligent Manual Fire Alarm for MXL, IXL, and XL3 Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS Fire Safety Boxes Durable Design Shock and Vibration Resistant '. Pull Down Lever Remains Down Until Reset Custom Microcomputer ChipTechnology Dynamic Supervision Reset with Allen Key No Break Rods Necessary TwoWire Operation Surface or Semiflush Installation . DPU or F P1-32 Programs and Verifies Device's Address and Tests Device's Functionality Electronic Address Programming is Easier and More Dependable Single and Double Action Models Available ®, Listed, CSFM, FM and NYMEA Approved Introduction Siemens BuildingTechnologies, Fire Safety MSI-10B and 20B intelligent manual fire alarm boxes provide the markets' most advanced method of address programming and supervision, combined with sophisticated control panel communication. Each MSI manual fire alarm box incorpo- rates a new custom microcomputer chip.The microcom- puter chip technology, and its sophisticated bi-directional communication capabilities with the control panel, achieves the state of an "Intelligent Initiating Device" Description The MSl-10B and 20B are constructed of durable molded polycarbonate material which is matte finished in red with raised white lettering.The housing accommodates a "pull- down" lever which, when operated, locks in position indicating the manual fire alarm box has been activated. The pull down lever remains down and locked until the manual fire alarm box is reset.The manual fire alarm box is reset only by opening the hinged housing cover with an allen key and then closing and locking the cover. I I I I I 1 I I I I I I I I other conditions which deteriorate mechanical addressing mechanisms are no longer a cause for concern. The MSI-10B and 20B are fitted with screw terminals for connection to an addressable circuit.They can be either surface or semif lush mounted. The MSI Series manual fire alarm boxes derive their power, communicate information and receive com- mands over a single pair of wires. The MSI Series is compatible on the same circuit with all IL and ID-60 Series ionization, photoelectric or thermal detectors, TRI Series interfaces or CZM Series addressable conventional zone modules. The MSI-10B and 20B intelligent manual fire alarm boxes are Underwriters Laboratories, Inc. listed. Current Draw 1 mA Ordering Information Model Description Shipping WI Lb. Kg. MSll0B Addressable Manual Fire Alarm Box, Single Action 2 .90 MSI-208 Addressable Manual Fire Alarm Box, Double Action 2.5 1.13 SB-SR Surface Mounting Box 1.5 .68 LIP Reset Tool Package (Contains 2 Tools) .5 .23 Mounting Data HOUSING HINGED TO NAMEPLATE BACKPLATE 1 Y,6 in s' HOUSING ,A, ll, Nil LOCKING \ \. " SCREW BACKPL.ATE SURFACE MOUNTING ENCLOSURE 'S •' SB5R 3 in 3½ in DEEP SWITCH BOX USER SUPPLIED) If-0 01 IX-1, 0 0 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 12/04 Brampton, Ontario Tel: (973) 593-2600 Siemens Building Technologies FAX: (973) 593-6670 Fire Safety Website: www.sbt.siemens.com/fis 10M SFS-IG Printed in U.S.A. Canada L6T 5E4 Tel: (905) 799-9937 December 2004 FAX: (905) 799-9858 Supersedes shoot dated 7/03 11 I I SIEMENS I TRI Series I Intelligent Initiating Devices Interface Modules for MXL Fire Detection Panels TRI-S,TRI-D,TRI-R ENGINEER AND ARCHITECT SPECIFICATIONS Interfaces and Supervises Normally Open Contacts Integral SPDT Relay (up to 4 amps) onTRl-R Model I I Fire Safety Dual Input onTRl-D Model Multi-color L.E.D. indicates status (green, amber, red) Easy front access to programming port and wiring terminals Mounts in 4 inch square 21/4 deep box, or double gang box Dynamic Supervision Comes with 5x5 inch faceplate Two wire operation SensorLink Model FPl-32 Programs and Verifies Device's Address and Tests Device's functionality Electronic Address Programming is Easy and Dependable UL Listed, ULC Listed CFSM, FM, NYMEA Approved I I I I I I Introduction The TRI Series' Intelligent interface modules are designed to provide the means of interfacing direct shorting devices to the MXL system's ALD loop circuit. The TRI Series Intelligent interface modules provide the market's most advanced method of address programming and supervision, combined with sophis- ticated control panel communication. Each TRI Series interface module incorporates a microcomputer chip. The TRI Series microcomputer chip technology and its sophisticated bi-directional communication capabilities with the control panel, achieve the state of an "Intelli- gent Device." Description The TRI Series Intelligent interface modules are avail- able in three models. The TRI-S and TRI-R are designed to monitor a normally open dry contact. The interface module reports the contact's status to the control panel. The TRI-S model can only monitor and report the status of the contact, while the TRI-R incorporates an addressable Form C relay. The TRI-R relay and contact device input are controlled at the same address. For the MXL system, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The TRl-D is a dual input module and is designed to supervise and monitor two sets of dry contacts. This interface module requires two address settings. The TRI-D is ideal for monitoring a waterf low switch and its respective valve tamper switch. The TRI has a multi-color Light Emitting Diode that flashes green when operating normally, amber if unit CATALOG NUMBER 6179 I I I I I I I is in trouble condition, and red to indicate a change of state. The TRI-D flashes twice, once for each address, the TRl-R red L.E.D. indicates a change of state in the relay. The device's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. SIEMENS Fire Safety's innovative technology allows all TRI Series intelligent interface modules to be programmed by using the SensorLink model FPl-32 Programmer/Tester. The F P1-32 Programmer/Tester is a compact, portable, menu driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The FPI-32 eliminates the need for mechanical addressing mechanisms, such as program jumpers, DIP switches or rotary dials, because the FPI-32 electronically sets the TRI interface's address into the interface's microcomputer chip nonvolatile memory. Vibration, corrosion and other conditions that deterio- rate mechanical addressing mechanisms are no longer a cause for concern. The TRI Series is fitted with screw terminals for connection to an addressable circuit. TheTRI Series is fully compatible' on the same MXL circuit with all intelligent F9 IL and ID-60 Series detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICR All TRI Series intelligent interface modules are UL listed. Environmental operating conditions for all TRI Series modules are 32°F (°C) to 120°F (49°C) with a relative humidity of not greater than 93% non-condensating. Ordering Information Model Description Shipping Wt. Lb. Kg. TRI-S Single Input loz. 2 '3111:4 Single Inputw/Relay loz. 2 TRI-Di Dual Input loz. 2 Mounting Data Addressable interface Model TRI-S, TRI-D, TRI-R mounts directly into a 4 inch square 21/4 deep box or a double gang box (user supplied). A 5 inch square off-white faceplate is included with each TRI. MOUNTING SLOTS FOR 4 INCH SWITCHBOX TRI-S/-D/-R MODULE OUNTING )LES FOR VITCH PLATE MOUNTING SLOTS FOR DOUBLEGANG S WITCH BOX Figure A Mounting the TRI-S/-R/-D Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (973) 593-6670 Website: wwwcerbpyro.com Fire Safety 2 Kenview Boulevard 4/02 Brampton, Ontario 10M Canada L6T 5E4 SFS-IG Tel: (905) 799-9937 Printed in U.S.A. FAX: (905) 799-9858 April 2002 S,,o,sodos slot dated 60 LI SIEMENS Fire Safety TR1=B6M I Intelligent Device Interface Module ENGINEER AND ARCHITECT SPECIFICATIONS I I I I I I I Intelligent Interface Modules For MXL and IXL Control Panels Interfaces and Supervises Normally Open (Fire Detection) or Normally Closed Contacts (Security Detection) Compact Size Allows Mounting in Single Gang Box Behind Equipment Operates with MXL ALD Loop, MXL XLD Loop or IXL ICon Loop Microcomputer Chip Technology Innovative Technology Supports Comprehensive System and Interface Communication Dynamic Supervision Two Wire Operation SensorLiNK, model FPI-32 Programs and Verifies Device's Address and Tests Device's Functionality Electronic Address Programming is Easier and More Dependable @ Listed, ULC Listed, CSFM and NYMEA Approved V • &' ' .- ,j -. Introduction TheTRI-B61VI Intelligent interface module is designed to provide the means of interfacing direct shorting devices to the MXL system's ALD loop circuit, MXL XLD loop or the IXL system's ICon loop circuit. TheTRl-B6M Intelligent interface module provides the market's most advanced method of address program- ming and supervision, combined with sophisticated control panel communication. Each TRI-B6M interface module incorporates microcomputer chip technology and its sophisticated bi-directional communication capabilities with the control panel. Description The TRl-B6M is designed to monitor a normally open or closed dry contact and reports the contact's status to the control panel. The device's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Siemens Building Technologies, Fire Safety Division innovative technology allows allTRl-B6M intelligent interface modules to be programmed by using the SensorLiNK model FPI-32 Programmer/Tester. The FPI-32 Programmer/Tester is a compact, portable, menu driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The FPI-32 eliminates the need for mechanical addressing mechanisms, such as program jumpers, DIP switches or rotary dials, because it electroni- cally sets theTRl-B6M interface's address into the interface's microcomputer chip non-volatile memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. ThisTRl-B6M is connected to the programmer/ tester with the programming cable provided with the tester. This cable utilizes two (2) alligator clip connec- tors, to attach to the TRl-B6M. (P/N 110-694927) The TRI-B6 Series has five leads, one for grounding, which are wired to the system with user supplied wire nuts. I I I I I I I CATALOG NUMBER 6170 The TRI-B6M is fully compatible on the same MXL circuit with all intelligent IL and ID-60 Series detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICR The TRI-B6M is also fully compatible on the IXL (ICon) circuit with all intelligent IL and ID-60 detectors and MSI manual stations. AIITRI-B6M intelligent interface modules are UL and ULC listed. Environmental operating conditions for alITRI-B6M mod- ules are 32°F (°C) to 120°F (49°C) with a relative humidity of not greater than 93% non-condensating. Engineer & Architect Specifications The addressable interface module shall incorporate a custom microprocessor based integrated circuit that shall provide communication with its compatible control panel. The addressable interface module shall be a Fire Safety TRI-136M that shall be compatible with a IXL or MXL control panel. TheTRI-B6M intelligent interface modules shall provide the means of interfacing direct shorting devices to the control panel's addressable circuits. The interface module shall report the contact's status to the control panel. The TRI Series devices shall be capable of and listed for interfacing normally closed security switches to the MXL (per UL 1076). The addressable interface module shall be UL and ULC listed. The addressable interface module shall be dynamically supervised and uniquely identifiable by the control panel. The addressable interface module's address shall be programmed with the use of a portable programming accessory. The programming accessory shall be a Fire Safety FPl-32 Programmer/Tester. The portable program- mer shall be menu driven. Once the desired address is entered the programmer shall set and verify the address. The programming accessory shall also be capable of testing the interface's functionality. The addressable interface module's address shall be set by electronic means only. No mechanical means such as programming pins, DIP switches or rotary dials shall be required. TheTRl-B6M shall be compatible on the same MXL circuit with other intelligent IL and ID-60 Series detectors,TRI Series addressable interfaces, MSI Series addressable manual stations or any other MXL addressable intelligent module. ThelRl-B6M shall be compatible on the same IXL (ICon) circuit as other intelligent IL and ID-60 Series detectors, MSI Series manual stations andTRI Series interfaces. Ordering Information Model Description Shipping Wt. oz. Kg. TRl86M Single Input 3.5 .1 TRI-86M-C ULC Model for Canada 3.5 .1 Typical Wiring (Refer to Figures 1, 2, 3 or 4) Refer to the appropriate wiring diagram below and wire the addressable inter- face module accordingly. Note: Recommended wire size: 18AWG minimum 14 AWG maximum I I Installing A Security Point I WARNING: These circuits intended for 24 hour alarm monitoring only. UL 1076 requires a TSW-1 tamper switch as well as a TSP-40 printer. A COMMUNICATION FAILURE with a TRI device configured for SECURITY results in a SECU- RITY ALARM as well as a communication trouble. When installing aTRI device in the CSG-M, be sure to set the device usage to security. When setting the device address using the FPl-32, select the normally closed alarm causing input. Connect only one switch perTRl input. Reminder: Proper installation procedure for TRI Devices As part of the normal installation practice each TRI device must be functionally tested. This includes testing the supervision through the end of the line resistor. The following steps must be followed for each TRI device installed: Open the end of line resistor. Check that the system annunciates the programmed trouble message. 3, Return the resistor to its proper connection. Change the state of the switch to confirm that the system's programmed response is executed. Return the switch to its normal state. I I E Mounting Diagram two - - - - - 9 L TRI-136M SINGLE GANG SWITCHPLATE (BLANK) (USER SUPPLIED) I I I I I I I NOTE: DO NOT USE REAR CONDUIT ENTRY LSINGLE GANG SWITCHBOX (USER SUPPLIED) I I 1 I I I NOTICE: The use of other than Fire Safety detectors and buses with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 12/03 Brampton, Ontario Tel: (973) 593-2600 Siemens Building Technologies 10M Canada L6T 5E4 FAX: (973) 593-6670 SFSG Tel: (905) 799-9937 December 2003 Fire Safety Website: www.sbt.siemens.comlfis Printed in U.S.A. FAX: (905) 799-9858 Sopercedes sheet dated 12/01 (ZR 'g ZH Series ZR Series Mountun Catalog Sheet SIEMENS Fire Safety & Security Products '08 Series Notification Appliances ZH & ZR - Strobes, Horns, & Horn I Strobes Application: Indoor Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (ZH) - Ceiling-mount models feature field-selectable Candela settings of 1513017519 5cd and 1151177cd - Wall-mount models feature field-selectable Candela settings of 15/30/75/110cd and 1351185cd - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce 1 flash per second . . - "Special Applications" listed with Siemens panels. .. . -, EZ Mount Universal Mounting Plate (ZBB) - uses single plate for ceiling and wall mount installations - EZ Mount design - with separate base plate - provides ability to pre-wire the base and test the circuit wiring before the walls are covered - ®UL Listed & ®ULC Listed; FM, CSFM & NYMEA Approved - ADA! NFPA compliant Specifications General - AudiblelVisual notification appliances shall be listed for indoor use only - Appliances shall be listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) - Appliances shall use a universal back plate, which shall allow mounting to a single-gang, double-gang, 4-inch-square, 4"-octal, or a 3-1/2"-octal backbox - Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate - Continuity check shall occur for entire NAC circuit prior to attaching any audible I visual-notification appliances - Dust cover shall fit and protect the mounting plate - Dust cover shall be easily removed when the appliance is installed over the back plate - Removal of an appliance shall result ma trouble condition by the Fire Alarm Control Panel, (FACP) '08 Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) Strobes - Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens - Strobes shall be available with two or four field-selectable settings in one unit, and shall be rated - per ®UL 1971 - for up to: 15/30175/110cd for wall mounted 1351185cd for wall mounted 1 5130175195cd for ceiling mounted 115/177cd for ceiling mounted - Strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 490C), and be listed for maximum humidity of 95% RH - Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) Audibles and Audible! Strobe Combinations - Horns and horn I strobes shall be listed for Indoor use under ®UL Standard 464 - Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output - Horns shall have at least 2 sound-level settings of 90 and 95 dBA Synchronization Modules - The strobe portion, when synchronization is required, shall be compatible with DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol - The strobes shall not drift out of synchronization at any time during operation - Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability to silence the audible, if required - Strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. - contacts remain closed) - All notification appliances shall be listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" ' Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on ®UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) Series ZH horns are listed under ®UL Standard 464 for audible signal appliances (Indoor use only) SIEMENS Industry, Inc. Building Technologies Division I I Mounting Diagram I 1 a - - zm- - EWA (Shown In Inches) Mounting Options SECURING kk SCREWS Fip.as3: tt.rion Fiaae4: Rsnve1 (See t€o B ti;-2znj I. Instal mounbtg ptate as shown in igure I to a single-gang, Impoitant: Device cs.y has one mcwthng orientatco. Ma:th the double-gang, 4 square. 4' octagon, or a 3 " octagon bactbcx top cf the base-to the top of the device. with the provfded pan head s:rews. To remove dwst cover, If it is desired to furtherse.ure the device to the base, then two place thtrmib and index finger on top edges of cover and pull oft optional screws are provided. To install these screws punch cut cover, the screw holes located a: the top and bottom of the device. Canned field wiring per figures 2 and 3 S. To remove the appliance, push a small f)at-bladed screwdnver Addresvires back into backboL into the side opening. The screwdiwer must clear the snap Place dust cover over mounting ptole to protect the tewninas release opening by % to disengage the snap. Do not prg off while perforatng wiring ccnlinuiy deck. housing with the screw driver. Apply pwssure with screw driver, Remove dust cover before snapçdtg or installing the aplrarce inserted in either side opening, as shown in, Fig 4 to reease the onto the mounting pfae per fig 3. housing. Technical Data ZH and ZH-MC Hcwn Rev.rbrant dBA PJ ®L1L464 ZH Horn Current Draw [ZH-MC and ZH at 24V] HOM 16-33 Volts (All?ps) 16.OV 24V 33.OV High 0.044 DC Lowa 0.018 Continuous High 83 87 90 Horn FWR 0.075 ________ Low' 0.045 Low 77 81 83 Code3Hornor High ig -ici n-s oi March Time *entwi5 the sarnefor the Conlinut 140m. Code .3 Etotn and March Tine Seth Low 1 72 1 76 79 *Available in sync mode only SIEMENS Industry, Inc. Building Technologies Division I I I I I I I I I I I I Ii I I I Technical Data - (continued) Models* €UL Listed Models and Ratings Operating Voltage (Special Application) [Per ®UL1971] (VDCNRMS) Voltage Range r ' 526-021 per@ (VDCNRMS) Horn - Mounting Strobe Candela (C) ZRMC 16.0-33.0 20.0-31.0 - Wall 15/30175/110 ZR-HMC 16.0-33.0 20.0-31.0 - Wall 1351185 ZR-MC-C 16.0-33.0 20.0-31.0 - Ceiling 15/30f75195 ZR-HMC-C 16.0-33.0 20.0-31.0 - Ceiling 1151177 ZH-MC 16.0-33.0 20.0-31.0 X Wall 15130i751110 ZH-HMC 16.0-33.0 20.0-31.0 X Wall 1351185 ZH-MC-C 16.0-33.0 20.0-31.0 X Ceiling 15/30175/95 ZH-HMC-C 16.0-33.0 20.0-31.0 X Ceding 115/171 ZH 16.0-33.0 20.0-31.0 X Wall or Ceiling - - 0AvabIe in red and white DC 16-33VDC FV 18-33VRM ® UL Current Ratings (ZR Strobe Only) Maximum RMS CurrentjAMPS) MC H (MC-C l-IMC-C 15cd I 30cd I 75cd 1110cdl 135cd 185cd 15cd 30cd I 75cd I 95cd 715cd 177cd 0.064 JU98 10.17510-233 0.318 1 0.445 0.069 0.111 10.20D 0.264 0.318 0445 0.105 0.164 0.268 0368 11482 0.684 0.117 0.160 0.297 0.398 0.482 0.684 Horn Setting ® UL Current Rat/n gZH Horn/Strobe Maximum tRMS Current (AMPS) MC I-IMC (MC-C i-IMC-C 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95 c 1115cd 177cd DC I - 16 33VDC 78 0.113 0.195 0.259 0.371 0.506 0.087 0.131 0222 0.292 0.371 0.506 70 0.107 0.188 0.246 0.324 0.455 0.075 0.121 0.213 0 277 0.324 0.4 FW E imoo-cl, 41 0200 0.302 0.406 0.521 0 722 0.149 0.216 0.331 0.436 0.521 0.722 16-33Vl 23 0.179 0.290 0.391 0.497 0.699 0.131 0.195 0.319 0.421 0.497 0.699 gent uraw is me same tor me conunuous riom; Code 3 Horn and March Time Settings Details for Ordering - (Including Mounting Options & Agency Approvals) I Agency Approvals Model Number Part Number Description Mounting Options* UL - ULC - FM - CSFM - ZH-R 500-636159 ZHorn: Red B,D,E,F X X X X ZH-W 500-636160 ZHorn: White B,D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F X X X X ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F X X X X ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F X X X X ZH-HMC-W 500-636164 ZHorn: Hi Multi Candela (Wall), White B,D,E,F X X X X I ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F X X X X ZH-MC-CW 500-636166 ZHorn: Multi Candela (Ceiling), White B,D,E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F X X X X ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F X X X X ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F X X X X ZR-MC-W 500-636170 ZStrobe: Multi Candela (Wall), White B,D,E,F X X X X ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B,D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B,D,E,F X X X X IZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E,F X X X X ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red B,D,E,F X X X X ZRS-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White B,D,E,F X X X X ZBB-R 500-636193 Accessory - (lncludes base, dust cover, mounting screws and installation sheet) ZBB-W 500-636194 Accessory - (lncludes base, dust cover, mounting screws and installation sheet) X listed! approved * Refer to catalog sheet #: 2585 for detailed mounting options Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard cirMrdc Indiictru mr Florham Park NJ 07932 Rrmntnn Ontario Building Technologies Division (9 December 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 7/07 URL: www.SBTSiemens.com/FIS FAX: (905) 799-9858 TI I I I I I I SIEMENS Catalog Sheet I Fire Safety & Security Products '08 Series Notification Appliances Mounting Options Mounting Diagrams I Mounting Matrixes I Mounting Notes ARCHITECT AND ENGINEER SPECIFICATIONS (A) UNIVERSAL MOUNTING PLATE 4" SQUARE, DEEP, FLUSH (60) (I) WPBBS • ORDER CODE— RED: 500-636137 0 o o (1 () i'tasliebackbox for surface mxrthrg AS series westherprooi.outdoor products. mc o 244 Used w1h Series Used with Series iI. AS Used wth Series AS,6.B1QHS,M9:DC.MH115. huH. AS (weatherproof) (B) SINGLE-GANG, FLUSH (60) (C) SINGLE-GANG, SURFACE (BC) (J) BBS BACKBOX NH. NS,SETSF, SETULC,ST,Zii.ZR ORDER CODE— RED: 500-636110 Standard steel backbox with knockouts DOUBLE-GANG, FLUSH (BO) for interior surface reounting, eonceaed con dcsitmouoig orsemi-fiush sppc-atons. 000, *1 > HOLES 0.0 0 Deep PRO'4tOEDWlT3i KNOCKOUTS FOR W C t5' COiOOiC5. Used with Series Used with Series Used with Sertes Used with Series AH, AS.B, AH, AS, MI'& NH, US. ST2t4,2R MH AH,AS. HSMTH.NI-I.ST,2H.ZA MHilATH-id-115, NI-t,ST (D) 4i1 SQUARE, FLUSH (BC) DOUBLE-GANG, SURFACE (BC) (K) WBBS WEATHER RESISTANT BACKBOX ORDER CODES— RED: 500636129 WHITE: 500-636131 -'. Sturdy die cast housing, threaded conduit hole and C) ,,__• and knockout for outdoor applaticws. L Deep 44 P Used with Series wCcio AH, AS, B6.B1OKS. MBDC,hlHllfi, MTH Used wth Series Used with Series NH, NS.SETSE SET-ULC. ST, ZHZR AH, AS, NH. NS, ST AH,88,610,MBDC,141-1115MTH-15-15 S:EfiF '08 Series Notification Appliances . 2 5 8 5 SIEMENS Industry, Inc. Building Technologies Division I I I I I I I 1 I I I 1 I I I I I I I (L) ISPS2 SURFACE ADAPTER (P) SBBS BACKBOX (1) WPSBBS ORDER CODES- WHITE: 500-636195 ORDER CODES— RED: 500-636119, ORDER CODES— RED: 500-636139, RED: 500-636196 WHITE: 500-636120 WHITE: 500-636140 t4 S0 For surface mounting speakers, chimes, and eIecronta applications. 1rir - r-'" -1 I•- 3-ME•'--•1 4 lap- Pill 5-5115." 3i6 4 2 S OEI _AC. S OS? with Series Used s Used wfTh Series Used with Series HS Ce .PTrI, B6. SW. CH. SEF. SET. SETFL ST-VP HS. M9C,Mi1{, NH NS, ST (M) FTT-SUR-BOX BACKBOX (Q) 4" SQUARE DEEP W/ EXTENSION (U) 5" SQUARE BACKBOX WI ORDER CODES- RED: 500-693168 RING, FLUSH (BO) EXTENSION RING? FLUSH (80) WHITE: 500-636118 -Ifa 30,1 1'1O[lh1_r Used with Series CK.StSEF.SETFL,SET (R) SFPS SEMI-FLUSH PLATE Used FT UI 0 wjith Series HS, SET ORDER CODES- RED: 500-636124, Used with Series (UTH, hlTW: For surface mounting on MT products.) WHITE: 500-636125 CftSE,SEF. SET Stamped alucnium surface wal ptate. (N) DBBS BACKBOX whioh mcsrnts betsind the basic una, (V) SSB-4 CEILING SUPPORT BRIDGE ORDER CODE - RED: 500-636111 and rvesrccever recessed backboxes in arm-tiush mounsng appbcaiicns. - 0 Standard steel back box prcw th ded w knocous for interior surface mounting, concealed conduit mo?.rnting or semi-flush applications. - - '00 f[ 0 HOLES HOLES } TAP Oo I Used with Series MI, SET, SE, NH, MS, ST Provisions for (4) J-nuts #8-32 lb 3-si? ?ROVioEOWirAseOoKOUTa—' FOR ?4'.cOOUn5. Square Matetiaf: Steel Used with Series {S} APS ADAPTER PLATE Used with Series ORDER CODE - RED: 500-636109 St A.' 1, AS, 86, SW, HS, MBDC, MH115, MTH, NH, SETSF, ST Stamped aluminum adapter plaze designed for (X) SHBBS applications whee aerni-8ush installations cannot or round backboxes s~ngle or double gang SQUARE, SURFACE BACKBOX ORDERCODES - RED 500 636126, (0) RETROFIT PLATE C,agon ORDERCODES - [PENDING) boxes or plaster rings. The, bacbx and basic unit WHITE: 500-636127 are then fastened to the plate. This type of mounting is referred to -as'ccnceeled conduit installation.' Site.. 4 ___ _ I a-jlE" Ii_I_ _ __ I —--i 1 (4)___________ HOLES Doe, Cm a C3 Used withSeries Used with Series Used with Series 86, 8W,MBOC,MTH NH, SE 88, 810,MSDC AV, AS, NH, ST SIEMENS Industry, Inc. Building Technologies Division (Y) SERS SQUARE SEMI-FLUSH (BB) SPSSB (EE) SPEXT EXTENSION RING EXTENSION RING ORDER CODES- RED: 500-636114, ORDER CODES- RED: 500-636116, ORDER CODES- RED: 500-636122 WHITE: 500-636123 WHITE: 600-636115 WHITE,* 50G-636117 l_ F i TOP tT / r oz _ 73251 13 D'S0.644 Used with Series _ Used with Series SE I e) CH, SE, SEF, SET (wall mount Used with Se~s SMC-CciIin Mount Strobe) Z) SBL2S BACKBOX (CC) SB-W 6" CEILING SUPPORT BRIDGE (FF) ZBB ORDERCODE- RED: 500-636121 ORDERCODE - WHITE: 500-634682 I-is4,. r - _ - - - ________ 237u •'YP Sri ORDER CODES - RED: 500-636193. WHITE: 500-636194 —L8U"-- I lk 03 J0 *1 _1I ri I- 1 PORWO ThPAD e.So , ex8-•32 Used with Series Used with Sèiies with3ei1es S__8 Ceiling Speakers z_____________________ (AA) SPSB (DD)!j.G PHR (GG) WFPS PLATE (HH) WFPAS PLATE ORDER CODES- RED: 500-636112, OX WHITE: 50636113 ORDER CODE 11 - - ORDERCODES - RED: 500-636135. WHITE: 500-636136 13 ORDER CODES - RED: 500-363133. WHITE: 500-656134 1-7 TOP 1r' 113 L___ 1l I V1 f I Used with Series Used withSeries Used with Series MI HAiP. . Used with Senes AS-WP SE (.Speakers) S 8' Ceiling Speakers I I I I I SIEMENS Industry, Inc. Building Technologies Division 1 I I I I F7 I I I I I I 1 NJ (I t U V V V - U' > U' . U' NJ NJ - - C - CD - _•- >C CD -n NJ DC DC C CD CD - CJ NJ - )< X w - 0 - o - C j CD CD CD >( DC C.Jr NJ 0 0 - O .- -o o -v - - DCgO 0 CD CD C m to C cu () m Ln m CD o - CD - DC - DC Ow . CD (0 Ln a — C') 2. 0• 0 -. CCC CD (A > Q C - 0 0 0 CD >< >< > '< - - - Series SET-C >< >< >< >< >< >< >< )< X > > >< Series ST >( >< > > Series ST-MC-RETRO >< >< < > > X x Series MHII5 >< >< > Series SE < > > I >< - >< >< >< >< > > - - - Series BI0-115 >< x >< X >< >< Series CH > > >< >< x > Series SETSF-B >< > >< Series SETSF > >< >< x >< < > )< >< > - - Series MBDC >< Series S-HQ '< >< > x > - - Series SET/SET wall Mount > > >< Series SE-C >< >< - ISeries Series MH >< >< >< >< >( >< x Series MTH > >< >< > >< >< > >< NS/NH >< x x x > >< I Series HS ><I >< > < >< x l x >< > SeriesAS/AH w ASeries Series AH-WB(3), MT-WP(4), MTH >< >< >< Z - - - - - - - - - - - - - - - - I I Mounting Matrix (by Model Number) 'I II IIh1 I Urrw I! .r•i' 'pr _____________ ii ii EIihi rj ' I '! inhi rII!IU ,Ip ri iliuiEkiihI iIiIiII1II h .rrrr' .rr'!! r:I1IIII•I'• ________ ihu oi l ,hiIhiII1111 , 11 ii I .111 iiI Ihili : • F u uIii ______________________ iv!uI!Iur!!! U!!IIuI 11111 I I I i ........... I I!iP iiih IiiFIilil I uu i IIiIIIiIik •iiiiflIhiIIII iIhIii ci Nil ! I' I b IIIIi tP!uII! IriIIb SIEMENS Industry, Inc. Building Technologies Division I I I I I I I I I I I I I I I I Mounting Notes Caution: The mounting options figures show the maximum number of field wires (conductors) that can enter the back box used with each mounting option. If these limits are exceeded, there may be insufficient space in the back box to accommodate the field wires and stresses from the wires could damage the product. Although the limits shown for each mounting option comply with the National Electrical code (NEC), Siemens recommends use of the largest back box option and the use of approved field wires whenever possible to provide additional wiring room for easy installation and minimum stress on the product from wiring. Caution: Check that the installed product will have sufficient clearance and wiring room prior to installing back-boxes and conduit, especially if sheathed multi- conductor cable or 3/4" conduit fittings are used. Mounting hardware for each mounting option is supplied. Conduit entrances to the back box should be selected to provide sufficient wiring clearance for the installed product. When extension rings are required, conduit should enter through the back box, not the extension ring. Use Steel City #53151 (1-1/2" deep) or #53171 (2-1/8" deep) extension rings (as noted in the mounting options) or equal with the same cut- out area. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the appliance. SIEMENS Industry, Inc. Building Technologies Division Use care and proper techniques to position the field wires in the back box so that they use minimum space and produce minimum stress on the product. This is especially important for stiff, heavy gauge wires and wires with thick insulation or sheathing. Do not pass additional wires (used for other than the appliance) through the back box "unless the back box is of a sufficient size to permit additional wiring as described in NEC 314.16 (B)". Such additional wires could result in insufficient wiring space for the appliance. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice, in accordance with Siemens Industry, Inc. standard terms and conditions. Back Box Mounting Siemens Wall-Mounted, Horizontal Strobe Appliances NFPA-72 (2007) 7.5.4.1 * —Wall-mounted appliances shall be mounted such that the entire lens is not less than 2030 mm (80 in.) and not greater than 2440 mm (96 in.) above the finished floor or at the mounting height specified using the performance-based alternative 7.5.4.5 7.5.4.2 - Where low ceiling heights do not permit mounting at a minimum of 2030 mm (80 in.), visible appliances shall be mounted within 150 mm (6 in.) of the ceiling. The room size covered by a strobe of a given value shall be reduced by twice the difference between the minimum mounting height of 2030 mm (80 in.) and the actual, lower mounting height. I I Back box Mounting Options* Series ASIAH Audible Strobe Series ST-MC-RETRO (Flush and Surface Retrofit Plate) Horn Series NS Strobe Series Z and ST Strobe Series MTH Multi-tone - 801N. - 61N. ____ 801N. ____ 61N. _____ 801N. 61N. 801N. ____ 61N. 801N. 61N. (B) 1-Gang x 2" Deep - Flush (80) 77'/f 81/f 78 I8 7 Is" 79 'Ia" 6 'Is" (D)4"x4"x 1.5' Deep- Flush (BO) 77" 9" 83 15/16" 77 7/ '18 78 I8" 7 Is" 79 15/" 6 1116 6 '16 (E) 4" x 4" x 2.125" Deep - Flush (80) 77" 9" 83 '/l6" 77 'Is" 8 '/" 78 Is" 7 i/s" 79 /16" 6 1116 6 1116 (F) 2-Gang x 3.5" Deep - Flush (BO) 77 112' 81/f 78 3/8" 7 Is" 79 1/8" 6 7/8 80 5 71,s" 5 116 (G) 2-Gang x 1.75" Deep - Surface (80) 77 '/2' 81/2' 78 /8" 7 Is" 79 'Is" 6 /8" 80 116 5 "isV 5 71,6 (M) MT-SUR-BOX Surface & Weatherproof (SP) - 79 3/s" 6 s/s" 6 5/8" (P) SBBS Surface (SP) 79 1/4 6 3/4" 6 3/4" (U) 5" Square Back box w/ Extension Ring, Flush (80) 591/f 81/f 83 71je 77 3/81, 7 5/8" 78 'Ia" 6 /8" 79 'us" 5 116 5 9i (X) SHBBS (SP) Shallow Surface 76 i/f 9 1/f 7 7 3/s" 8 5/8" 78 1/8 7 '/a" (Z)SBL2S Surface (SP) - - 78" (FF) ZBB 78 '/8" 7 '/" More Back box Series CH Series SET-V Series SEF-C Series SET-C Chime Strobe Speaker Strobe Speaker Strobe Speaker Strobe Mounting options* 80 IN. 6 IN. 80 IN. 6 IN. 80 IN. 6 IN. 80 IN. 6 IN. SBB Surface (SP) 77-3/4" 8-1/4" 79-3/16" 6-13/16' 77-3/4" 8-1/4" 77-3/4" 8-1/4" 4" x 4" x 2.125" Box wl 1.5 77-1/2' 7-1/2" 80 6" 78-1/2" 7-1/2" 78-1/2" 7-1/2" Extension Flush _Ring _-_ _(BO) (U) 5" Square Back box with 78" 7" 79-1/2" 5-1/2" 78' 7" 78" 7" _Ring _- Extension Flush (BO) SHBB (SP) Shallow Surface ________ 4"x 4"x 1.5" Box wl 1.5" 78-1/2' 7-1/2" 80" 6" Extension-Ring Plate - Flush (BO) 1 1 * Measured from Bottom of Back box Notes: (BO) = By Others (SP) = Siemens Product I I I I I I I I I I I I I I I I I Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 IsHI L6T 5E4 / Canada December 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 hct dated 7/07 URL: www.SBT.Siemens.com/FIS FAX: (905) 799-9858 - Fig. 1 MODEL 302 For interior mounting in any JJ atmosphere that is compat- ible with terminal screw type connections. I I I I I I I I I I, I 1 I I I I I I I Four BasicModels MODEL DESCRIPTION REFER TO: 302-135 135°F - Interior Vertical Mounting FM &UL F 1 Fig. 302-194 194°F - Interior Vertical Mounting FM & UL -l35 135°F - All Weather Vertical Mounting FM & UL F 2 Fig. 302-ET-194 194°F - All Weather Vertical Mounting FM & UL 302-AW-1 35 135°F - All Weather Vertical Mounting FM & UL Fig. 3 302AW-194 194°F - All Weather Vertical Mounting FM & UL 302-EPM-135 135°F- Explosion Proof Mounting UL Fig.4 302-EPM-194 194°F - Explosion Proof Mounting UL Decorative white plastic adapter plate for mounting 302, 302Ff Fig. 5 g. and 302AW to any 3" outlet box or 4" octagon outlet box. Fig. 2 MODEL 302-El Hermetically sealed for moisture proof or, dust proof installations. Requires no special back box. Has plastic hexago- threads for attachment to threaded hub cover, or any nal grip bushing with 1/2" conduit outlet box. Must be hand • Fig. 3 MODEL 302-AW I Hermetically sealed for moisture proof or dust proof installations. Requires no special back tightened only. For - box. For indoor and outdoor use. Protect from indoor and outdoor direct sunlight and adverse weather conditions. A use. Protect from direct sunlight and adverse weather & V Fig 4 MODEL 302-EPM ; Explosion proof for installation in hazardous locations. Has hexagonal grip bushing with 1/2' conduit threads for attach- ment to threaded hub cover of series JL fixture fitting as manu- factured by Killark Electric Co., or equal. Must be hand tightened only. For Interior use. General Each model is a normally open device designed especially for fire detection and alarm systems. These rate compensation type detectors are available in either 1350 F. or 1940 F. ratings. All four basic models are self restoring, hermetically sealed, shock and corrosion resistant, and are tamper proof. Refer to NFPA STANDARD 72, STANDARD FOR AUTOMATIC FIRE DETECTORS for application requirements, testing and maintenance. Principal of Operation All models operate on the principles of a rate compensation detec- tor. The detector consists of a high expansion aluminum tube which encases two insulation struts with opposing open constant points (see cut-away view). The high expansion sensing shell and the expan- sion struts have a different coefficient of expansion. A slow rate of temperature rise allows the heat to penetrate the inner expansion struts. Therefore, the tubular shell and the struts expand slowly until the total device has been heated to its rated temperature level of 135° F/i 94°F. At this point, the silver contact points close which initiates the alarm. When subjected to a rapid rate temperature rise there is not as much time for heat to penetrate the inner strut. The rapid lengthening of the shell allows the struts to come together at a lower level which compensates for thermal lag inherent in conventional fixed temperature detectors. When the surrounding air temperatures goes below the rated temperature level, the shell contracts which forces contacts to open, thus automatically resetting the detector. (actual size) liver contact points sion struts xpansion sensing 040 anodized ;ontrol sleeve g screw hermetic seal Dimensions (Model 302): Total overall length 4 1/8 Special Considerations Base Diameter: Z. Temp. Rating OF Max Ceiling Temp. °E 135 115 194 155 Approvals/Listings Detectors are not directionally effected, can be mounted horizontally Signaling or vertically. Detectors have a smooth ceiling UL rating of 50' x 50' Underwriters' Laboratories (2500 sq. ft.) on 8 to 10 ft. ceilings. Detectors, hub covers, or outlet Listed boxes must never be installed in direct sunlight. Refer to NFPA STAN- DARD 72 for spacing and other considerations. For further information ______ Factory Mutual refer to www.thermotechheatdetectors.com Ap(0V•d Electrical Rating California State Fire Marshall. Listing No. 7270-0021:001 Voltage Current MEA Acceptance # 193-03-E 6-125 VAC 5 amps 6-25 VAC 1 amp 125 VDC 0.5 amp 'I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. k7 650067 0144, Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 I Email: Peter.pawchak@siemens.com DESIGN: ModeiMXL and MXL-IQ fire alarm control units. Coded or noncoded; local, auxiliary, I remote and central station proprietary service; automatic, manual waterflow, releasing service and sprinkler supervisory service when used as a remote station (protected premise) unit or proprietary fire receiving unit. Refer to listee's data sheet for additional. detailed product description and operational considerations. Basic components: (MM-11, -21,31VSMB-12, -22, -32 Main Control Board I MKB)-1 1, 214, -51, -62 Keyboard/Annunciator Panel MPS6-12Power Supply CRM Relay Module CSM-4 Signal Module I CZM-4 Conventional Zone Module BTX-1, BP-61 Battery Set Module MSE-21, -32, -3M2 Enclosure MSE-3M-D Enclosure Door I iléntKni6ht51285129 Dialer/DACT (Listing No. 7300-0559:120) 1 - For use with Model MXL only. 2 - For use with Model MXL-IQ only. I RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's listed Model VoiceCom system (CSFM Listing No. 6911-0067:173) and separately listed compatible initiating and indicating I devices. See (CSFM Listing No. 7300-0067:172) for optional control unit accessories. *Also suitable for high-rise applications. Refer to listee's Installation Instructions Manual for details. I These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, *9th Edition Standard NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum I Retard/Reset/Restart period must be adjusted to 30 seconds or less. Combined with 7170-0067:154 I *Rev. 06-23-2009 fm I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational I ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7007017 Page 1 of 3 CATEGORY: 7300 - MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com I I I I I DESIGN: Control Unit Accessories. Refer to listee's data sheet for additional detailed product description and operational considerations. Accessories are listed as follows: MODELS DESCRIPTION ICP-86 Intelligent Control Point Module CZM-1, -1 B6 Remote Conventional Zone Module FS-CZM Conventional Zone Module ALD-2/ALD-21 Analog Loop Driver Module TSP-40, TSP-40A Logging Printer PSR-1 Remote Power Supply MOI-1/M0I-7 Voice/Annunciator Drive MOD-16 Output Driver NET-4/NET-7/NET-7M Communication Interface MOM-4/MOM-2 Module Card Cage TSW-1 Tamper Switch CMI-300 Modem Interface Module PIM-i Printer Interface Module PAL-1 Printer CP-2297/CP-2341 Line Suppressor XL Graphic Software MXL-G Graphic Interface PS-5A/-35, -5N/-5N7 Power Supply/Network Node LIM-1 Loop Isolator Module DC-355 Voltage Regulator Module CSG-M Compare Program MMM-i Coil Cord Microphone TMM-i Master Telephone Handset TBM-1/TBM-2 Terminal Block Module EL-410C/410D Signaling Amplifier VSM-i Visual Switch Module OMM-1/OMM-2 Output Master Module OCC-1/OCC-2 Output Control Card ASC-1/ASC-2 Supervisory Module BTC-i Backup Tone Card ACM-1 Audio Control Module CCU/M Pager Interface RDM-PC, -MXL Diagnostic Interface Modules I I I I I I I I I I *Rev. 05-04-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed !\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I TSM-1 Test Switch Module ZCx-8B-XX/ZCx-4Abxx Control Card Modules ZCT-8 Telephone Module MBR-2fME-3/MLE-6 Enclosure Backbox MDR-2 Enclosure Door cMBR-MP/M BR-3MP Enclosure Plate Insert MHD-X 'Enclosure Inner Door Panels MDACT Multi-Pont Digital Communicator Transmitter CAB1-COM, CAB1-X Enclosure CAB2, CAB3 Expanded Enclosure HUB-4 Communication Card Module NCCNT-WAN Wide Area Network VSB-1 Inner Door Blank MKB-1 /-2/-3 Keypad/Annunciator Modules MID-16 Input Module NIM-1 RIREP-1 Network Interface/Repeater NCC/NCC-G, -GL/NCC-T Computer D2300CP, D2300CPS, D2325CPS Fiber Optic Repeater BI-35 Power Supply Interface BC-35 Battery Charger AE-30U Class B Bell Circuit BB-55 Battery Enclosure ALI-8, ALI-813 Remote Phone Enclosure MTE-2 Interface Enclosure ZAC-30 Zone Amplifier Module XLD-1 Analog Loop Driver XED-1/-2 Back Box XEA-1I-2 Adapter Plate ACM-RKIMKB-RK/MMB/RK Rack Mount Kit MOM-RK/MPS-RKITSP-RKNSM-RK Rack Mount Kit VFM-1 Fan Control Module MEM-1 Memory Expander Module RCM-1 Distributed Audio Card MSE-3U-3LR Enclosure Backbox MET-3U-3LR Flush trim Kit IQ-DFU-BLANK Dead Front Panel VLM-1 Visual LED Module PLC-4 Power Limited Module DMC-1 Digital Message Card NIM-1M Modem Assembly NlM-1W Network Interface Module NCCNT-G, -GL, -T Network Command Center DFM, DFM-BRK DNet Fiber Module, Bracket FJ-303, -304 Phone Accessories HCP Intelligent Control Point Module OD-LP, -BP, -GP, -BP-R, -GP-R Outer Door (Black or Red) MOM2-XMP Mounting Plate for MOM2 Module XMl MDACT Interface I I I I I I k I I I I I I I I Listing No. 7300-0067:0172 Page 2 of 3 *Rev. 05-04-09 bh This listing is based upon technical e the test results and/or other data but endorsement or recommendation of requirements or installation criteria. information sources. Date Issued: July 01, 2010 data submitted by the applicant. CSFM Fire Engineering staff has reviewed does not make an independent verification of any claims. This listing is not an the item listed. This listing should not be used to verify correct operational Refer to listees data sheet, installation instructions and/or other suitable Listing Expires June 30, 2011 I I I Authorized By: FRANCIS MATEO, Program Coordinator 11 Fire Engineering Division Listing No. 7300-0067:0172 Page 3 of 3 SSD-INTL, SSD-C-INTL Systems Status Display ALCC* Audio Level Conversion Card RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Siemens, model number, electrical rating and UL label. APPROVAL: NOTE: I I I I I U I I I I I I I Rev. 05-04-09 bh TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 1307Q 0067 0152 Page 1 of 2 CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Control unit accessories as listed below. Refer to listee's data sheet and control unit's installation instructions for additional detailed product description and operational considerations. PSR-1 Remote Power Supply NET-4, -7, -7M Communications Interface MOI-1/MOI-7 Voice and Annunciator Driver MOD-16 Output Driver VCP-25 Remote Indicating Device Zone Output Module FT-301/C/CL, FT-302/C/CL Remote Telephone Station FJ-303, PT-303, -304, Remote Telephone Station FJ-30355, -304, -304SS Remote Telephone Station CP-2297 Signal Line Suppressor CP-2341 Supply Line Suppressor PAL-1 Printer MID-16 Input Module VDT Video Display Terminal ICP, ICP-136 Intelligent Control Point Module PIM-2, RSE-i Printer Interface Module RCC-1, RCC-1 FfRCC:2, RCC-3, RCC-3F Remote Command Center CP 7537-394 Computer CP 7554-001, CP-7574, CP-7574T Monitor SCD-19M, -19TM, SCD-21M, -21TM Monitor *SCD17L -1 71-T, -19L, -1 91-T Monitor (Flat Screen) MXL-G/CXL-G Graphic Interface CPP Multiplexer LLM-i Leased Line Module CP-7585-33/-661-1 00/-Pi 33 Computer SCD-550, -550T, -550-DOS Computer AIC-4Z, NCC-i F Interface Card RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible *Rev. 07-17-2007 jw , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \./ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I NOTE: I I I Listing No. 7300-0067:0152 Page 2 of 2 control units. Refer to listee's Installation Instruction Manual for details. I I I I I I I *Rev. 07-17-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CJT-o067:O221 Page 1 of 1 CATEGORY: 7315— POWER UNITS LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Model(!AD-3 notification appliance extender/distributed power module/power supply and Models EN-PAD, EN-PADR enclosure. Unit comprises of a printed circuit board housed in the EN-PAD or EN-PADR enclosure. The PAD-3 monitors with the polarity of its two input circuits to determine when to operate its four notification circuits. The PAD-3 also provides on trouble relay contact and an auxiliary power circuit. Refer to listee's installation/operation manual for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Unit shall be fully supervised and shall have the 24-hr battery back up as required per code. MARKING: Listees name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as notification appliance extender for use with listee's separately listed compatible fire alarm control units. This unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002. Refer to manufacturer's Installation Manual for details. NOTE: I U I I I I I I I *Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I I I I I 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. c72-op67c2o3 Page 1 of 1 CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models FP-11HFP-11, and *HFpo.11 analog and FPO-11 photoelectric type smoke detectors. Models FP-1, and HFP-11 also have a supplemental 1350F heat sensor. Model DGH-1 1 detector guard housing suitable for use with Models HFP-1 1, *HFPo11 and FP-1 1 smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These detectors are intended for installation on a vertical wall surface or the ceiling. They are also acceptable for duct application with an air velocity of 0-4000 ft/mm. when used with Models DB-1 1 DB-HR or DB-X11RS bases. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with listee's separately listed base Model DB-11, DB-HR or DB-X11RS (CSFM Listing No. 7300-0067:134) and separately listed compatible fire alarm control units. Model DGH-1 1 detector guard housing is listed for use only with FP-1 1 and HFP-1 1. Refer to listee's Installation Instruction Manual for details. NOTE: I I I I I I I I I *Rev. 09-27-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an \/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I III I I 1 I I I I [I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. J27070067026 Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Model.FT-1f'electronic fixed temperature heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 1350F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number, temperature rating and UL label. APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units. Intended for use with listee's Model DB-11 base (CSFM Listing No. 7300-0067:134). NOTE: I I I I I I I I I I I Rev. 10-26-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed . the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I Li I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION .... . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300:0067 0134, Page 1 of 1 CATEGORY: 7300 - MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models D134T, D134TS, DB4F, DB4TF, DB4FS, D133S, AD133, ADBX3, DB-HR, DBX3RS, DB-11: DB-X1 1 RS, ADBI60, ADB-1 1, ADBH-1 1, ADBX-1 1 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3 auxiliary relays. Model DB-11 is suitable for use only with Model RR-1 1 or RR-1 1 F auxiliary relay. Models DB-11 base, ADBH-11 audible base, and DB-HR relay base are intended to be used with Models HFP-1 1 and HFPT-1 1 Intelligent Series smoke and heat detectors (CSFM Listing No. 7272-0067:223 and 7270-0067:224). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model DB-1 1, ADBH-1 1 and DB-HR may be installed on the ceiling or on the wall. MARKING: Listee's name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and fire alarm control units. NOTE: *Rev. 10-28-2002 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. C71O0967'003 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models MS-5,-51,-52,-52C,-53 through -57,-60,-6ODAP,-6ODP,-6OKS,-151,-157, -500 through -507, -511, -512,-512C,-513, -513C, -514, -514C,-515,-516, -517, -517C, -518, and MS-MI; MH-51, -57, -501, -507, -511, -517, -517C, -518; MSX-1, -2, -21D, -100; MHX-1, -100rMl-1, -2, -10, 0B -20,-20B, -60, -6ODA; MSI-MB6; HMS-S, -D, -M noncoded manual pull stations. Single action, double action, and double action distinct type. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Cerberus Pyrotronics, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed electrically compatible fire alarm control units. Models with prefix MH are suitable for use with Halon extinguishing system. Models HMS-S, -D, -M are addressable. * These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTE: I I I I I I I I I *Updated 06-22-2009 fm , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed e the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I Li I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. ö0-0067:0i46 Page 1 of 1 I CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 ' Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models TRI-2, TRI-2D, TRI-2R, TRI-60, TRI-60D, TRI-60R, TRI-136, TRI-136D, TRI-136R, '.TRI B6M TRIDTRI Iand TRI S addressable modules and TRI CB supervisory module I Refer to listees data sheet for additional detailed product description and operational considerations. RATING: I INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: APPROVAL: Listee's name or Cerberus Pyrotronics, model number and UL label. Listed as control unit accessories for use with Model XL3 (CSFM Listing No. 7165-0067:104 and 7170-0067:151), Model MXL (CSFM Listing No. 7165-0067:144 and 7170-0067:154) or IXL (CSFM Listing No. 7165-0067:138 and 7170-0067:153) fire alarm I control units. The TRI-CB module is designed for use with the TRI-2, TRl-2D and TRI-2R modules when interfaced with the INX module. NOTE: I I I I I I *Rev. 10-26-2002 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an Js endorsement or recommendation of the item listed. This listing should not be used to verify correct operational I requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-O067:0252 Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. - Models ST-MC-CW, ST-HMC-CW, R-MC-CR, ZR-MC-CW, ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd ZR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -Ware wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: 9-1 O-2007mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed e the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 712-0067:0248 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division, 8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns / Strobes. Models NS-MC-CR, NS-MC-CW, NS-HMC-CR, NS-HMC-CWZH-MC-CR, ZH-MC-CW, ZH-HMC-CR, ZH-HMC-CW are horn / strobes for ceiling mount only. Suffix CR or CW are for ceiling and color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115/177 cd NS-MC, ZH-MC = 15/30175/110 cd ZH-HMC, = 135/185 cd Flash Rate: 60 flashes I minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as audible and audible II visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details Note: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: I I I I I I I 09-07-2007 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I FT I I, I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270--002-1--0001A Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech Inc.,2900 North 1000 West, Ogden, UT 84414 Contact: Sherman Barker (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AWO2ET and 302EPM heat detectors. Units are open circuit, c1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-ET or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-El and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. I I I I I I L I I *Rev. 05-01-2003 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I I I I I I I I H so 1' POWER COMMUNICATION SYSTEMS, INC SALES - SERVICE - ENGINEERING Public Address * Paging * Intercom * Fire Alarm * Nurse Call • CCTV I I : WARRANTY Power Communication Systems, Inc., warrants its work and/or material supplied to be in substantial I compliance with plans and specifications as set forth. Material purchased from, and installed by Power Communication Systems, inc., is warranted to be free from defects in material or workmanship for a period of one year from date of acceptance, or first beneficial usage, whichever occurs first. The undersigned does hereby agree to repair or replace at their own expense, during normal I working hours, any equipment or workmanship provided and installed by them found to be defective. I They also agree to repair or replace at their discretion any materials sold by them and installed by others for a period of one year from date of sale. This is an over-the-counter warranty and is limited to materials returned to them with proof of purchase. This warranty shall not apply to any material sold' 'àr'installed by Power Communication Systems, Inc.-, which has been subject to abuse, misuse, neglect, accident, or use contrary to instructions I furnished. All requests for warranty service must be accompanied by a valid Purchase Order and "Bill To" address. When applicable, invoices for warranty work will indicate "No Charge". I In the event the undersigned fails to comply with the above within a 30 day period after official written notification of failure or defect, the owner shall have the right to repair it at their discretion at Power Communication Systems expense. POWER COMMUNICATION SYSTEMS, INC. Ernest Power Ill DATE P.O. Box 600066, San Diego, CA 92160-0066 4643-A Mission Gorge Place, San Diego, California 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431—C7/C1O 05/25/2011 14:11 16i.5830647 FOt'ERCOM PAGE 02 - FILE COPY POWER COMMUNICATIONSYSTEMS, INC. So 'L141 SALES - SERVICE - ENGINEERING 4Jl Public Address' Paging * Intercom Fire Alarm * Nurse Call' CCTV FIRE ALARM SYSTEM RECORD OF COMPLETION f:A It O632. 1 PROTECTED PROPERTY INFORMATION Name of property: Kaiser Permanente MOO Carlsbad Address: .6860 Avenida Encinas, Carlsbad, CA 92008 Description of property: Medical Office Building Occupancy type: 8 -- -. Name of property representative:Kaiser Foundation Hospitals -. Address: 393 East Walnut Street, Pasadena, CA 91188 -- Phone: 714-970-4500 -- Fax: - E-mail: Authority having jurisdiction over this property: City of Carlsbad - Fire Prevention Division - Phone: 760-602-4665 Fax: E-mail: 2. FIRE ALARM SYSTEM INSTALLATION, SERVICE AND TESTING INFORMATION Installation contractor for this equipment: Power Communication Systems, Inc. Address: 4643 Mission Gorge Place, Suite A San Diego, CA 92120 Phone: (619) 583-7400 Fax: (619) 583-0647 - E-mail: Service organization for this equipment: Power Communication Systems, Inc. Address: 4643 Mission Gorge Place, Suite A San Diego, CA 92120 - Phone: (619) 583-7400 - Fax: (619) 583-0647 E-mail: Location of as-built drawings: Location of historical test reports: Location of system operation and maintenance manuals: A contract for test and inspection in accordance with NFPA standards is In effect as of: Contracted testing company: -- Address: Phone: Fax: E-mail: Contract expires: Contract #: Frequency of routine inspections: 3 TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter reference of System Type: Name of organization receiving alarm signals with phone numbers (fcippIicabIe): Alarm: Emergaricy24 Phone: 866-571-4146 Supervisory; Emergency 24 Phone: 866-571-4146 Trouble: Emergency 24 Phone: $66-571-4146 Entity to which alarms are retransmitted: Power Communication Systems, Inc. Phone: 619-583-7400 Method of retransmission of alarms to that organization or location: -- P.O. Box 600086, San Diego, CA 92160-0066 '4643-A Mission Gorge Place, San Diego,Caiifornla 92120-4133 (619) 583-7400 1, Fax: (619) 583-0847 License No. 636431—C7/CIO 05/25/2011 14:11 16195830547 POWERCOM PAGE 03 TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8, note the means of transmission from the protected premises to the central station: E Digital Alarm Communicator McCulloh E Multiplex 2-way radio E 1-way radio El N/A If Chapter 9, note the type of connection: Local energy EJ Shunt E N/A 3.1 SYSTEM SOFTWARE Operating system (executive) software revision lever: 4.0 Site-specific software revision d Revision completed by: 0. Jay Hill SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to the system (see NFPA 72, Table 6.6.1): Quantity: - 2 1 Style: 4 Class: B S. ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5); Quantity: 2 Style: 4 Class: B 5.1 MANUAL INITIATING DEVICES 5.1.1 MANUAL PULL STATIONS Type of devices: El Addressable IJ Transmitter 5.2 AUTOMATIC INITIATING DEVICES 5.2.1 AREA SMOKE DETECTORS Type of coverage: Complete Area E N/A Type of devices; LJ Addressable Transmitter Type of smoke detector sensing technology: 5.2.2 DUCT SMOKE DETECTORS Type of coverage: Type of devices: E Addressable Transmitter Type of smokedetector sensing technology: El Conventional EJ Coded N/A El Partial Area E Non-required partial area Conventional Coded E N/A U Ionization Photoelectric Number of luct smoke detectors: U Conventional U Coded II N/A U Ionization El Photoelectric 6.1 SPRINKLER SYSTEM Number of valve supervisory switches: Type of devices: LI Addressable LI Conventional LI Coded LI Transmitter LI N/A 6.2 FIRE PUMP Type of fire pump: LI electric LI Diesel Type of fire pump supervisory devices: LI Addressable LI Conventional LI Transmitter LI N/A 1 LI Coded 85/25/2011 14:11 16195830547 POWERCOM PAGE 04 5.2,3 HEAT DETECTORS Type of coverage: CJ Complete Area LI Partial Area LI Non-required partial area ED N/A Type of devices: LI Addressable LI Conventional LI Coded El Transmitter LI N/A 5.2.4 SPRINKLER WATERFLOW DETECTORS Type of devices: Addressable LI LI Transmitter LI 5.2.5 ALARM VERIFICATION Alarm verification on this system is: LI Enabled Conventional LI Coded N/A Number of devices subject to alarm verification LI Disabled LI Set for seconds 6 SUPERVISORY SIGNAL-INmATING DEVICES AND CIRCUrrS Fire Pump Functions Supervised LI Fire pump power LI Fire pump running LI Fire pump phrase reversal LI Selector switch not in auto LI Engine or control panel trouble 0 Low fuel Other: 6.3 ENGINE-DRIVEN GENERATOR Type of generator supervisory devices: LI Addressable LI Conventional LI Coded LI Transmitter LI N/A LI Engine or control panel trouble LI Generator running LI Selector switch not in auto LI Low fuel 7. ANNUNCIATORS 7.1 ANNUNCIATOR 1 LI Local LI Remote Type: LI Addressable LI Directory LI Graphic LI N/A Location: Building Entrance Courtyard 7.2 ANNUNCIATOR 2 LI Local LI Remote Type: LI Addressable LI Directory LI Graphic LI N/A. Location: 05/25/2e11 14:11 16195830647 POIIERCOM PAGE 05 7.3 ANNUNCIATOR 3 El Local El Remote Type: El Addressable El Directory El Graphic 21 N/A Location: S. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1. EMEREGENCY VOICE ALARM SERVICE Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: - Number of speaker zones: 8.2 TELEPHONE JACKS Number of telephone jacks installed: Number of telephone handsets stored on site; Type of telephone system installed: Electrically powered El Sound powered E21 N/A 8.3 NON VOICE AUDIBLE SYSTEM Characteristics of notification device circuits connected to this system (see NFPA 72 Table 6.5): Quantity: 8 Style: V Class: B 8.4 TYPES AND QUANTITIES OF NONVOICE NOTIFICATION APPLIANCES INSTALLED Bells: With visual device: Horns: 23 With visual device: 23 Chimes: -- With visual device: Bells: With visual device: Visual devices without audible devices: 83 Other. (describe): - EMERGENCY CONTROL FUNCTIONS ACTIVATED El Hold-Open Door Releasing Devices El Smoke Management or Smoke Control El boor Unlocking El Elevator Recall El Other SYSTEM POWER SUPPLY 101 PRIMARY POWER Nominal Voltage 120 VAC -- Amps 2 AMPS - Overcurrent protection: Type Circuit Breaker Amps 20AMPS Location (of primary supply panelboard): ElectricalRoom Disconnecting means location: 10.2 SECONDARY POWER Location: Type: Battery Nominal Voltage: 12V Current Rating; Number of standby batteries: 2 Amp hour rating 18 A Location of emergency generator: 05/25/2011 14:11 16195830647 POI4ERCOM PAGE 06 10.2 SECONDARY POWER (continued) Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: In alarm mode: RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conduction operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) NFPA 72 Ei NFPA 70, National Electrical Code, Article 760 21 Manufacturer's published instructions E Other (please specify): System deviations fr erenced NFPA standards: Signed: Printed: D. Jay Hill Date: 5/4/2011 Organization: PowerCommunicationSystems,Inc. Title: Forman Phone: (619)583-7400 RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: El NFPA 72 0 NFPA 70, National Electrical Code, Article 760 Manufacturer's published instructions El Other (please specify): Documeot1bR in accordance with Insoection and Testing Form lFieure 10.6.2.31 Is attached Signed: Printed: D. Jay. HI II - Date: 5/4/2011 Organization: Power Communication Systems, Inc. Title: Forman Phone: (619) 583-7400 CERTIFICATIONS AND APPROVALS 13.1 SYSTEM INSTALLATION CONTRACTOR This system as 5 herein has been installed and tested according to all NFPA standards cited herein. Signed: - Printed: D. Jay Hill Date: 5/4/2011 Organization,/ - -PowerçmrnunicationSystems,Inc. - Title: - Forman - Phone: ' -(619)583-7400 05/25/2011 14:11 16195830647 PO4ERCOM PAGE 07 13. CERTIFICATIONS AND APPROVALS (continued) 13.2 SYSTEM SERVICE CONTRACTOR This system as spe herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed: 0. Jay Hill Date: 5/4/2011 Organization: ---.Power Communication Systems, Inc. litle: - Forman Phone: (61)583-7400 13.3 CENTRAL STATION This system as specifi in will be monitored according to all NFPA standards cited herein. Signed: Printed: 0. Jay Hill Date:5/4/2011 Organization: Power Communication Systems, Inc. Title: - Forman Phone: (619)583-7400 13.4 PROPERTY REPRESENTATIVE I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed; _ Printed: Date: -- Organization: Title: Phone: 13.5 AUTHORITY HAVING JURISDICTION I have witnessed a satisfactory acceptance test of this systems and find It to be installed and operating properly In accordance with its approved plans and specifications, Its approved sequence of operations, and with all NFPA standards cited herein. Signed: —Printed: Date:__________ Organization: ,/l<1i. - Title: Phone: