Loading...
HomeMy WebLinkAbout111 SEQUOIA AVE; ; FPC2018-0170; PermitPERMIT REPORT rcity of Carlsbad Print Date: 09/29/2021 Job Address: 111 SEQUOIA AVE, CARLSBAD, CA 92008-4028 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot#: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check U: Project Title: Description: THE SHORES AT CARLSBAD - FIRE ALARM TI - PANEL REPLACEMENT Permit No: FPC2018-0170 Status: Closed - Finaled Applied: 06/04/2018 Issued: 06/18/2018 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: FPContractor: FIRE WATCH 522 FRONT ST EL CAJON, CA 92020-4233 (619) 299-3473 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov DF-52416:D • A3-20 S-5UD(E)/IMS.0 OUD(E) Series Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel 8 Fllre.uTeeAtarms by Honeywell [iiiLit1 The MS-51JID-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-I0UD-7E offers the same fea- tures as the MS-5UD-3 and MS-I0UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-10UD-7 - ten IDCs. Style V (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-i OUD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-10UD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A © 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-1 OUD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D.07/26/2010—Page 1 of USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE Top SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power -TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC © 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). (Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Depth = 5.207" (13.23 cm) _______ Door= 16.821(42.73 cm) Depth = 5.257" 01 Backbox = 16.65" (42.29 cm) 3.353 cm) Door = 19.26" (48.92 cm) Backbox =19 .0".(48.26 cm) Left Side Bottom Right Side Cabinet Measurements Page 2of 4—OF-52416:D 07/26/2010 I! Minimum Battery Size: 7 AH. Initiating Device Circuits - TB4 (and TB 6 on MS-10UD-7 only): Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7). Alarm Zones 6 - lOon TB6 (MS-10UD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - TB5 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form C Relays - TBB: Relay I (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-51JD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-i OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: V Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style V (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. IR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-52416:O • 07/26/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators......................................................................8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.0A MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS.7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26° (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00 (48.26 cm.) high x 16.65 (42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring (TR-CE): 22.00° (55.88 cm.) high x 19.65° (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00° (50.80 cm.) high - 22.5° (57.15 cm.) wide - 8.5° (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- lure ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:0214 MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FlreLtte® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is Strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 933=1=1 U .1 We cannot cover all specific applications or anticipate all requirements. EIG lf&lNl &MMIMCI1UNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:1) • 07/26/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10-UD-7E Fire alarm control units. The MS-SUD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANNSEC; Secondary ANN-BUS Module *IpDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct nv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division [LdT TJ GENERAL SPECIFICATIONS GENESISTm NPH BATTERY SERIES i_96 IA&MA rr n ru r fl - NPH2-12FR 2 68 2.68 51 2.01 88 3.46 0.84 1.85 2 'A NPH3.2-12 NPH3.2-12FR 12 3.2 134 5.28 67 2.64 64 2.52 1.38 3.05 3 NC GENESISTm NP BATTERY SERIES (fri.) mm cm.) mm , )bs) NP1-6 1 NP1-6FR . 6 . - 1.0 51 2.01 42. 1.65 57 2.24 0.28 0.61 5 A NP1.2-6 NP1.2-6FR 1.2 - 97 3.82 25 0.98 56 2.20 0.30 0.67 1 A NP2.8-6 NP2.8-6FR 2.8 67 2.64 33 1.30 105 4.13 0.59 1.30 5 NC NP3-6 NP3-6FR 3.0 134 5.28 33 1.30.1 67 2.64 0.69 1.53 1 A NP3.2-6 NP3.2-6FR 3.2 66. 2.60 33 1.30 104 4.09 0.59 1.30 5 A NP3.8-6 ' NP3.8-6FR 3.8 66 2.60 33 1.30 125 4.92 0.75 1.65 1 A - NP4-6 NP4-6FR 4.0 70 2.76 47 1.85 '105 4.15 0.80 1.76 5' NC NP4.5-6 NP4.5-6FR 4.5 . 70 2.76 47 1.85 105 4.15 0.86 1.90 5 NC NP5-6 NP5-6FR 5.0 70 2.76 47 1.85 105 4.15 0.95 2.10 5 'NC NP7-6 NP7-6FR 7.0 151 5.95 33 1.30 100 3.94 1.28 2.83 1 NC NP8.5-6 NP8.5-6FR 8.5 98 3.86 56 2.20 118 4.65 1.60 3.53 9 NC NP10-6 NP10-6FR 10.0 151 5.95 50 1.97 101 3.98 1.99 4.38 1 NC NP12-6 NP12-6FR 12.0 151 - 5.95 - 50 - 1.97 - 1 101 1 - 3.98 - 2.04 - 4.48 - 1 - - NC NPO.8-12 NPO.8-12FR . 12 0.8 96 3.78 25 0.98 1 61 2.42 0.37 0.82 7 . HA NP1.2-12 NP1.2-12FR 1.2 97 3.82 48 1.89 56 2.20 0.57 1.25 3 A NP2-12 NP2-12FR 2.0 150 5.91 20 0.79 89 3.50 0.70 1.54 8 B NP2-12-C NP2-12CFR 2.0 182 7.17 , 24 0.93 61 2.40 0.73 1.61 6 L NP2.3-12 NP2.3-12FR 2.3 178 7.01 35 ' 1.38 67 2.64 1.02 2.15 1 A NP2.6-12 'NP2.6-12FR 2.6 134 5.28 67 2.64 66 2.60 1,36 3.00 3 ' A NP2.9-12 NP2.9-12FR 2.9 79 3.11 56 . 2.20 105. 4.13 1.24 2.73 1 NC' NP3-12 NP3-12FR 3.0 132 5.20 33 1.30 1 105 4.13 1.18 2.60 1 NC NP3.4-12 NP3.4-12FR 3.4 134 5.28 67 2.64 67 2.64 1.39 3.06 3 NC NP4-12 NP4-12FR 4.0 90 3.54 70 . 2.76 107 4.21 1.70 3.74 1 NC NP4.5-12 NP4.5-12FR 4.5 90 3.54 70 2.76 107 4.21 1.76 3.88 1 NC NP5-12 NP5-12FR 5.0 90 3.54 70 . 2.76 107 4.21 1.81 4.00 I NC NP7-12 NP7-12FR 7.0 151 5.95 65 2.56 100 ' 3.94 2.59 5.72 4 NC NP12-12 NP12-12FR 12.0 ' 151 5.95 98 . 3.86 100 3.94 4.06 1 8.95 4 C NP18-12 NP18-12FR 17.2 181 7.13 76 3.00 167 6.57 6.17 13.60 2 D/E NP24-12 NP24-12FR 24.0 .166 6.54 175 6.89 125 4.92 9.07 20.00 2 C/DIE NP33-12 NP33-12FR 33.0 197 7.76 131 5.16 158+ 6.22+ 11.79 26.00 1 E/F NP35-12 NP35-12FR 35.0 198 7.80 132 5.20 ' 170 6.69 12.61 27.80 1 . F NP38-12 NP38-12FR 38.0 197 7.76 165 6.50 172 6.77 14.59 32.16 12 FIG NP55-12 NP55-12FR 56.3 229 9.02 138 5.43 207+ 8.15+ 18.01 39.70 1 .M/G NP65-12 NP65-12FR 65.0 ' 350 13.78 166 6.54 174 6.85 23.63 52.10 2 FIG P75-12 NP75-12FR 77.5 259 10.20 169 6.65 208+ 8.19+ 26.50 1 58.42 1 MJG NP90-12 NP90-12FR 90.0 304 11.97 168' 6.61 229+ 9.02 31.18 68.74 1 M/G NP100-12 NP100-12FR 100.0 329 12.95 174 6.85 214+ 8.43+ 32.94 72.62 1 J/G NP120-12 NP120-12FR 120.0 407 16.02 173 1 6.81 1 235 9.25 '38.41 84.68 1 ' J/G NP150-12 NP150-12FR 150.0 483 19.02 170 6.69 241 9.49 47.13 103.90 1 J/G NP200-12 NP200-12FR 200.0 520 1 20.47 260 10.24 208 8.19 73.00 160.93 3 K/G OATASAFETM NPX BATTERY SERIES o ? ru uu mm (mn.) rr ' NPX-35-6. NPX-35-6FR 6 35W/Cell 8 151 5.95 33 1.30 100 3.94 1.43 3,15 1 NC NPX-50 NPX-SOFR 50W/Cell 13 151 5.95 50 1.97 100 3.94 2.09 4.60 1 NC NPX-25 NPX-25FR , 12 , 23W/Cell -5 90 3.54 70 2.75 107 4.21 1.95 4.30 1 NC NPX-35 NPX-35FR 35W/Cell 8 ' 151 5.95 65 2.56 100 3.94 2.75 6.06 4 NC NPX-80 NPX-80FR 80W/Cell 20 181 7.13 76 2.39 167 6.57 6.35 14.00 2 D/E NPX-100 NPX-100FR 95W/Cell 28 166 6.54' 125 4.92 175 6.89 9.70 21.38 2 DIE NPX-135 NPX-135FR 135W/Cell 33 197 7.76 131 5.16 158+' 6.22 11.94 26.32 1 E/F NPX-150 NPX-150FR 150W/Cell 40 197 7.76 165 6.50 172 6.77 14.29 31.50 2 FIG FOOTNOTES: FR: IJL94-VO, Flame Retardant Case and Cover (Oxygen index 28) + Height Is top cover. Overall Height, including terminal Is dependent on the terminal configuration Recognized by UL File No. MH16454' NOTE: All dimensions are +/- 0.08 Inches (2mm): Weights are +1- 5% - 2 www.enersys.com - Torque Specifications: MS bolt: 26.6 lbf.in (3Nm) +1- 5% M6 boll: 44.31 lDf.in (5Nm) +1- 5% MS receptacle: 35.4 IbLin (414m( +/- 5% M6 receptacle: 65 lbf.in (6.8Nm) +/- 5% Publication No: US-NP-RS-004 • March 2008 107 LAYOUT ILLUSTRATION ___ 1 _____ L. TI I wi I 2 ____ ____ ___ L. TI I WI I 3 ____ j L lie I I 4 ____ L___ fI I wi I ____ 51 ___ L TI el I wi I L1 01 lie U® I I U® I 6 7 _____ 8 i L Ii el TERMINAL ILLUSTRATION LA 5.255 8.35 L.B. 1i 110.472 ICHMM 11.99 C INCH.MM 0.313 7.95 .'. INCH &MM 0.472 11.99 1' : 0. :0.PJ !! 1 .020 e3s 0 007 2 260 6.35 0.031 07 0. 10 J- OA53 11.51 -. 004 0,251 310 7.87 M5Tfd1 piIe Me Bf ft RtI -'ST N2N LlL'C' 0.860 21.84 0.530 13.48 15.92 J __ ' Mi 0.910 23.11 ' 0.33 : 1.024 26.01 I ( .IH 1.100 27.94 5.910 23.11 0.E 12.9: 9.91 I L L___ :::: 1:: 8.38 'lNCIi 0.870 22.01 0.550 13.97 dE@) t 18.00 MEB 0.808 20.47 0.760 19.30 0.6300 17.53 0.394 10.01 0.335 8.50 a 0.08 in. for all height dimensionsUM. 0 .89 s Note: Dimensions are in inches (mm) Tolerance are ± 0.02 in. for dimensions < 5mm ± 0.04 in. for dimensions 2-.5mm unless otherwise specified. Charging Standby use: Apply constant voltage charging at 2.275 volts per cell (or 2.25-2.30VPC). Cyclic use: Apply constant voltage charging at 2.40-2.50 VPC. Initial charging current should be set at less than 0.25CA. Top charge: Product in storage (ambient temperature 25C/77F) requires a top charge every six months. Apply constant voltage at 2.40 volts per cell, initial charging current should be set at less than 0.1 CA for 15 to 20 hours. Discharge Stop Operation when voltage has reached the minimum permissible voltage. Recharge Immediately. Do not operate at 6CA or more current continuously. Storage Always store battery in a fully charged condition. If battery is to be stored for a long period, apply a recovery top-charge every 6 months. Store batteries in a dry and cool location. 3 www.enersys.com Temperature Keep within ambient temperatures of -15C to +50C for both charging and discharging. Incorporating battery into equipment Encase battery in a well ventilated compartment. Avoid installing battery near heated units such as a transformer. House the battery in the lowest section of the equipment enclosure or rack to prevent unnecessary battery temperature rise. Others Avoid terminal short circuit. DO NOT expose to open flame. Avoid setting batteries in environments which can cause direct contact to gasoline, paint thinner, organic solvents, synthetic resins, oil, etc. Publication No: US-NP-RS-004 • March 2008 4 ' RELATIONSHIP BETWEEN CHARGING VOLTAGE AND TEMPERATURE INEEMEN .1 I Milli— 1 UUI!* TllIr,, a Its 6900 lILly. 4.IVI tO05T601 VOLTACLCMAIGIPIC ! VOLVAG, 14.0 LD 4.00 -uric. IXSBISCNAIOL uu ---.ufltClON5ISr9(4IEE S Is Is 20 15 00 II 40 Charging Time (Hours) WIN TESTING CONDITIONS: DISCHARGE CURRENT: 0.I7C HAp. (FY. I.TWCELU CHARGING CURRENT: 0.09C Amp. CHARGING VOLUME: 125% OF DISCHARGED CAPACITY AMBIENT TEMPERATURE: 2W C (68F TO 779 IAH%) 00 400 000 400 000 i:oa 450 Number of Cycles FLOAT SERVICE LIFE NP SERIES TESTING CONDITIONS: FLOATING VOLTAGE: 2.25 TO 2.30V/CELL AMBIENT TEMPERATURE: 20C TO 22C (68F TO 72F) OCR> 120 4nZ 20 Life (Year) ------- DISCHARGE CHARACTERISTICS 11 1 L, liIiI1IP! uiiiiIuiui • 1111111 milli MEN 00111MI EnerSys P.O. Box 14145 Reading, PA 19612-4145 USA O'F5d/ Solutions Tel: +1-610-208-1991 +1-800-538-3627 www.enersys.com EnerSys Europe Zurich, Switzerland Tel: +41(0)442157410 EnerSys Asia Guangdong, China Tel: +86 755 2689 3639 Distributed by: © 2008 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted. (E)POTTER The Symbol of Protection These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. BELLS PBA-AC & MBA-DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8' (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -400 to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells -4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (nmi) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .1 7A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .1 7A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-I PAGE I OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance (146) I II (86) (127) 33/8" 4 /4" (lOB) OWES 776-2 (E)POTTER The Symbol of Protection Bells Dimensions Inches (mm) Fig. I BELLS PBA-AC & MBA-DC Wiring (rear view) Fig. 3 VI 2 11116" 68) A.C. BELLS WHITE(IN) wHrrE(olrn FROM CONTROL PANEL OR PRECEDING BELL BLACK (IN) BLACK (0111) CAUTION, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 0 WOlf 776.1 NOTES: I. WHEN USING AC BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. OWO# 776-I Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6' below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). WA WtNLN Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 2 OF 2 01/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0328:0119 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BIIIW©pottersignal.com DESIGN: Models 5B624-153075, 5B624-75110, PBA246, PBA248, PBA2410, PBAI206, PBA1208, PBA12010, PBD-126, *PBD128 *PBD1210 *PBD246 PBD-248, * PBD-2410 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6", 8" and 10'. Models MBA-6,-8 and -10 bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PBA-246, -248, -2410: 24 VAC PBA-1206,-1208,-12010: I20VAC MBA-6,-8,-10: 12or24VDC *pBD126 -128, -1210: 12VDC, .12A *PBD246 -248, -2410: 24VDC, .06A INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. "Revision 01-31-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division