HomeMy WebLinkAbout3068 STATE ST; ; FPC2018-0333; PermitC(city of PERMIT REPORT S Carlsbad Print Date: 09/29/2021 Permit No: FPC2018-0333 Job Address: 3068 STATE ST, CARLSBAD, CA 92008-2367 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 10/05/2018 Valuation: $0.00 Lot #: Issued: 10/25/2018 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: REVISED PLANS FOR STATE AND OAK -NEW FIRE ALARM SYSTEM MIXED USE Applicant: FPContractor: iii ENTERPRISES THE STEINHILBER CORPORATION MARIOAGUERO 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x209 FEE AMOUNT FIRE New Alarm System $1,265.00 FIRE Plan Review Per Hour - Office Hours $136.00 Total Fees: $1,401.00 Total Payments To Date: $1,401.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov vfmfvp FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS STATE & OAK 3068 STATE STREET CARLSBAD, CALIFORNIA FIRE ALARM SYSTEM MATERIAL DATA SHEETS r;;;;3 3068 State ST i REVISED PLANS FOR STATE AND OAK - NEW FIRE ALARM SYSTEM MIXED USE 4/2/2019 FPC20I 8-0333 .1 FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER NFW-100X ADDRESSABLE FIRE ALARM CONTROL PANEL CSFM# 7165-0028:0505 TELGUARD TG-7FS CELLULAR FIRE ALARM COMMUNICATOR CSFM# 7300-1157:0136 SPACE AGE ELECTRONICS INC. FAD 5SU0685 FIRE ALARM DOCUMENTS RED CSFM# 7300-0553:0110 NOTIFIER N-ANN-80 REMOTE ANNUNCIATOR CSFM# 7120-0028:0240 NOTIFIER FCPS-2456 REMOTE POWER SUPPLY CSFM# 7315-0028:0225 NOTIFIER NP-200 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0028:0503 NOTIFIER NOT-BG-12LX MANUAL PULL STATION CSFM# 7150-0028:0199 NOTIFIER NH-200 ADDRESSABLE HEAT DETECTOR CSFM# 7272-0028:0502 NOTIFIER NMM-100P ADDRESSABLE MINI MODULE CSFM# 7300-0028:0230 NOTIFIER NC-100R ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0230 NOTIFIER 302 SERIES RATE ANTICIPATION HEAT DETECTOR CSFM# 7230-0021:0001 SYSTEM SENSOR PC2WL,P2RL CEILING AND WALL MOUNTED HORN/STROBE CSFM# 7125-1653:0503 SYSTEM SENSOR P2RK OUTDOOR HORN STROBE WALL MOUNTED CSFM# 7125-1653:0188 SYSTEM SENSOR HW-LF CEILING MOUNTED LOW FREQUENCY SOUNDER CSFM# 7135-1653:0223 NOTIFIER® by Honeywell NFW-IOOX Intelligent Addressable FACP with Communicator General The FireWarden-1 OCX (NFW.IOOX) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series. The NFW-1 OCX comes with e pre-installed communicator and sup- ports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previ- ously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's Internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features Listed to UL Standard 664,1Oth edition re-instaIled IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® Automated activation of the NFC-50/100 Emergency Command Center NFC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Geritex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walk test with walk-test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports FlashScan® and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressable detectors and 99 modules) Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) Four independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A DN-60959:A .3/6/2018 - Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or . selected from an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS Fire Alarm (red) • CO Alarm (red) AC Power (green) • Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) • Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad • Acknowledge Alarm Silence • Drill (Manual Evacuate) Four (4) programmable function keys • Reset (lamp test) PRODUCT LINE INFORMATION NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. POTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-100X (red). DP-ES-B: Optional dress panel for NAN-i OOX (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. Optional cabinet for up to six modules mounted on CHS-6 chassis. Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-I20: Remote battery charging system for lead-acid batteries witb..a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-I OOR: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR( duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(M duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951 R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951 R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. Page 2 of 4— DN-60959:A • 316/2018 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. FlashScan only. FST-951 H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. NN-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low-profile ionization smoke detector. NI-100: Addressable low-profile ionization smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low<rcifile photoelectric smoke detector. FSP45IT: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-1 OOT: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(VV) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(VI) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-I 00: Fast-response, low-profile heat detector. FST-851R: Fast-response, low-profile heat detector with rate-of-rise option. NH-i OOR: Fast-response, low-profile heat detector with rate-of-rise option. FST-851H: Fast-response, low-profile heat detector that activates at 190°F188°C. NH-i OOH: Fast-response, low-profile heat detector that activates at 190°F/88°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-Al 00: Addressable low-profile multi-sensor detector. B200SR: Addressable sounder base. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order FSP-851 R, FSP-951 R, or NP-1 OOR separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertig'L (Order FSP-851R, FSP-951R, or NP- 48R separately.) Addressable Modules FMM-I: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-I00: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-I: Dual Monitor Module. Same as NMM-1 00 except it provides two Style B (Class B) only IDCs. NDM-I00: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only lDCs. FMM-I01: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-i OOP: Miniature version of NMM-1 00. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-i: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-i 00: Similar to NMM-1 00. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-I: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style YIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NC-i OOR: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. Ni 00-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- loop. NMM-i 00-i 0: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200ROR135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIXi 35: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-i 2LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-bOX, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N100-ISO (DN-6994), NP-100 series (DN-6995), NH-100INH-100R (DN- 6997), DNR/lnnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM- 100 (DN-6999), NC-100 (DN- 7000), NC-IOOR (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ FZM-1/FMM-101 (DN-6720), FCM- 1/FRM- I (DN-6724), NOT-BGI2LX (DN-7001), NBG-I2LX (DN-6726), and Fire Wa rden SLC Manual (52304). DN-60959:A • 316/2018 - Page 3 of 4 SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits................................................1 Addressable device capacity..................................................198 Programmable software zones.................................................99 Annunciators.............................................................................16 Electrical Specifications AC Power: 120/240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18 A lead-acid batteries. Battery Charger Capacity: 7-I8AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 k - 22 k ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-zrited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Addressable Device Accessories End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- lOOP, and NC-100 module circuits. The 3.9k ohm assembly super- vises the NZM-1 00-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). —AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). —REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet-switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 CSFM: 7165-0028:0505 iso 000i :b dl 1=1.1 ENIINM I MJJtOMZtVRU QUIITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up4o4ane and accurate. We cannot cover at specific applications or anticipate all requirements. All specifications are subject to change without notice. PJarmNetS, NOTtFIERrk, FireVrden, SWIFT. and System SensorS NOTI F ER are registered trademarks of Honeywell Intemotionat Inc. MiosnftS and 12 Clintonville Road WindowsS are registered trademarks of the Microsoft Corporation. ® NOTIFIER Northford, CT 06472 52018 by Honeywell International Inc Allrights reserved. Unauthorized use of this document is strictly prohibited. () 203.484.7161 www.notifier.com by Honeywell Country of Origin: USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0505 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FireWarden-50X (NFW-50X) and FireWarden-100X (NFW-100) Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The FireWarden-50X (NFW-50X) is a compact version of the FireWarden-100X (NFW-100). The FireWarden-50X (NFW-50X) has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The FireWarden-100X (NFW-100) has 198 addressable device capability and 4 Notification Appliance Circuits with 3.0amps total 24VDC output in Alarm expandable to 6.oamps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models FireWarden-50X (NFW-50X) and FireWarden-1 OOX (NFW-1 00) system components are as follows: IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module N-ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module N-ANN-I/O LED Driver Module N-AN N-S/PG Serial/Parallel Interface Module N-ANN-RLY Form-C Relay Module N-ANN-LED Annunciator Module N-ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model FireWarden-100X (NFW-100) system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. 04-04-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0505 Page 2 of 2 MARKING: Lktes name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. XLF: 7165-0075:0500 04-04-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division n ATA VOLY TELGUARD TG-7FS LTE-A P/N: TG7LAFO1 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS ó COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for long, sunset-free installation. 1- Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. I Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. all TlU7d units. Ta sealess Gommunication Gente cornpliit and pvid connectivity between anel, the Telguardjf products and the central station. Iquar Thnical Support pvides a s11 g1e pomtof contact for both celsei,vJce q u_es tio ris. 0 #7* TELGUARD TG-7FS I CELLULAR ALARM I COMMUNICATOR LTE-A I FOR LTE NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. 55 UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 central station burglar alarm units; Lirsecurity servcies Residential 985 • Household fire warning systems 1023 Household burglar alarm systems ULC Listings S545 Canadian household fire warning systems S304 Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems Fai the most curlent pioduct specifications and UL Listings visit wwwlëlguard.com. SECURITY SIGNALING , — C us & . . NFPA 11 ESAEZ Connected LISTED INTERNATIOMAL CoSt by AT&T Telguard, a Division of Telular corporation 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com copyright 2017 Telular corporation All Rights Reserved C C1ZOI7RovB CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA001 *TG7LA,01 TG7LA002, *TG7LAF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other.non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 - Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ACE-Il I FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2Y4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information A-0-0-AAM ISO ~~01 C A _______ Space Age Electronics, Inc. *0175"~ " .M...11111111. REGISTERED www.lsae.com OO] Made ISA. NFPA ®r CdMPANY 800,486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-13 Connector P,op.,ty lnlo,m,llon — - Carliftations and App,o.I, 16.1 SyIen In,l,5Olion Co,6,.,j,,: 16.5 AhoI1ty Hing Jiti4,O 1* Equlp,,,.nl Inlorn,atlon MInln1n, R.qW,.d Don,.,,I.1Ion (SIG-FUN) I Mqd.dflm 4------- ?en.,,IaIum,.l..... .MDQS .t.t,S.MIO II 4,W.Iç 41 MCO.I 7.4 44&I7fl LT10644 6.4.l Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 1300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCXJA 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFXlD enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorserrrit or recommendation of the item listed. This listing should not be used to verify correct operational reuirernents or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-71 14:c • A1-65 NOTIFIER® Serial Annunciator by Honeywell Annunciators General N-ANN-80 80-Character LCD The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remte control of critical system functions. (A keyswitch prevenLs Unauthorized operation of the control switches.) Up to eight N-ANN-805 may be connected to the ANN-BUS of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS, such as the NFW-50. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. N-ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory. :3ne, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4° square electrical box. Semi-flush mount to single, double, or 4° square electrical box. Use ANN-SB80KIT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight N-ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative -humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375° (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375' (3.49 cm.) deep. For use Indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-SO. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7120-0028:240 MEA: 442-06-E Vol. 2 The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. dn-7114:c • 5/22/09 - Page I of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-BUS communica- tions circuit. To determine the type of wire and the maximum wir- ing distance that can be used with FACP ANN-BUS accessory modules, it is necessary to calculate the total worst case current draw for all modulson:a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. All connections are power-limited and supervised. A maximum of eight N-ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. *6,000ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2.,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. = TBI ANN-BUS Device ORDERING OPTIONS: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80K1T-B: Black surface mount backbox with angled wedge. ANN-SB80K1T-W: White surface mount backbox with angled wedge. NFW-50 12345678 FACP Wiring to ANN-BUS Device ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. iso goO 1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BIN(lN All specifications are subject to change without notice. , QUALITY SYST5 Made in the u.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-7114:c • 5/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: 7120-0028:0240 Page 1 of 1 7120— ANNUNCIATORS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models N-ANN-80 and *N ANN 80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. 712O0075: 021 1 Rev 12-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCPS-24S6(C/E) & FCPS.. 24S8(C/E) 6- & 8-Amp 24-Volt Remote Power Suoolies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be corrected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S60 & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a sync-follower' or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). Four ClassB (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet- 15"H x 14.5W x 2.75"D (cm: 3.1H x 36.83W x 6.985D). dn-6927:a ©TllDt ® by Honeywell • • • IS • S • Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-2456E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16V). Trouble Conte--t Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuils: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24S6: 4.0 A maximum. - FCPS-24:38: 6 0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-2436: 6.0 A maximum. - FCPS-24S8: 8.0 A maximum. Secondary Power Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. dn-6927:a • 04/30/09 - Page 1 of 2 Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the nOtification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e. follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator' mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-24S6C & FCPS-2458C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A. 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A. 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A. 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12124 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINIEMNS a MANUFACTUNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-6927:a • 04/30/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL Im - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:0225 Page 1 of I CATEGORY: 7315— POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-O3KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NP-200 Series Addressable Photoelectric Detectors General The NOTIFIER NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series Addressable Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indi- cation. Dual electronic thermistors add 135°F (57°C) fixed tempera- ture thermal sensing on the NP-200T. The NP-200R is a remote test capable detector for use with DNR Series duct detector housings. Features SL LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the FireWarden panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0° (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA1 OOZ. DN-60979:A NOTIFIER® by Honeywell NP-200 in B300-6 Base Mount base (all base types) on an electrical backbox which is at least 1.5° (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. NP-200R mounts in a DNR/DNRW duct detector housing. Operation Each NP-200 Series detector uses one possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire- Warden Series for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 200 pA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0° (5.3 cm) high; base determines diameter. - B300-6: 6.1° (15.6 cm) diameter, - B501: 4° (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). Installation Operating temperature range: NP-200 series plug-in detectors use a detachable mounting base to • NP-200: 0°C to 50°C (32°F to 1220F); simplify installation, service and maintenance. • NP-200T: 0°C to 38°C (32°F to 100°F). NP-200R: installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). DN-60979:A • 3/29/18 - Page 1 of 3 Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the NP200 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listed: S911 CSFM: 7272-0028:0503 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates 17kishScanO and CLIP device. NP-200: White, Addressable photoelectric detector; B300-6 base included. FlashScan only. NP-200-IV: Ivory, Addressable photoelectric detector; 8300-6 base included. NP-200T: White, Same as NP-200 but with thermal element; B300-6 base included. FlashScan only. NP-200T-IV: Ivory, Same as NP-200 but with thermal element; B300-6 base included. NP-200R: White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. FlashScan only. NP-200R-IV: Ivory, Remote test capable addressable photoelectric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) 6300-6-IS: White, 6" base isolator. (CSFM: 7300-1653:0109 Pend- ing) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base, (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, E.L-C listed. 6300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) 6501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. (CSFM: 7300-1653:0109 Pending) B501 BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) 6224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol.. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653.0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60979:A • 3/29/18— Page 2 of 3 NOTIFIER® and FIREWARDEN® are a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S o 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I ____________________ All specifications are subject to change without notice. ;b dl I .1 ININllRlNG 11 MANUFACTURING QUA I IT Y SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-60979:A • 3/29/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed-Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131 *13224RB (CSFM No. 7300-1653:0126); 13200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B21OLP 13300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM No. 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to rnriufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-7001:D • A1-380 0 NOTIFIERJ Intelligent/Addressable Devices General NOT-BGI 2LX Addressable Manual Pull Station The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-la or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-ganq, or 4° (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[131); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4° (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The NOT-BGI2LX Addressable Manual Pull Station The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automaticaly resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 99 on NFW2-100/NRN2-100C, 1 - 50 for N FW-50/N FW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4° (10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Pagel 012 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two, Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULIULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E Vol. IV. CSFM: 7150-0028:0199. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® is registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 000i We try to keep our product information up-to-date and accurate. g We cannot cover all specific applications or anticipate all requirements. INUfiINI &MNUFACTURINC All specifications are subject to change Without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2— DN-7001:D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-12L, NBG-I2LX, NBG-12LA, NBG-12P5, NBG-12LSP, NBG-12LPS, NBG-I2LPSP, NBG-125P, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-12L.AO, NBG-12L0, NBG-I2LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. - -. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Corrected 10-08-12 bh This listing is hased upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60980:A (0 NOTIFIER® Detectors for FireWarden Series by Honeywell Addressable Devices General NH-200 Series Intelligent Addressable Thermal The NOTIFIER NH-200 Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the NH-200 Series ideal for both system operation and build- ing design. The point ID address, set using rotary decimal switches, provide specific detector locations. Compatible with FireWarden Series fire alarm control panels. The series includes a 1351F/571C fixed-temperature, rate-of-rise and a 190°F/880C fixed high-temperature detectors. These thermal detec- tors provide effective, intelligent property protection in a variety of applications. Features SL-C. LOOP: Two-wire SLC loop connection. Unit uses base for wiring. ADDRESSING: Addressable by device. Rotary, decimal addressing. Please refer to the FireWarden panel manuals for device capacity. ARCHITECTURE: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identification. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. OPERATION: Fixed temperature model (NH-200) factory preset to 135°F (57°C). Rate-of-rise model (NH-200R),150F (8.3°C) per minute. High-temperature model (NH-200H) factory preset to 190°F (88°C). 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. • Visible LEDs blink" eveMime the unit is addressed. MECHANICALS: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and mainte- nance. Separate base allows interchange of photoelectric, ionization and thermal sensors. OTHER SYSTEM FEATURES: Remote test feature from the panel. Walk test with address display. Low standby current.94-5V plastic flammability rating. Options: Remote LED output connection to optional RA100Z remote LED annunciator. NH-200R in B300-6 Base Flanged surface mounting kit. Installation NH-200 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class 'B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of fire-resistant plastic. The NH- 200 Series plug-in intelligent thermal detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each NH-200 Series detector uses one of 159 (panel dependent) possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The NH-200 Series offers features and performance that represent the latest in thermal detector technology. Specifications Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5% to 3.5%. Size: 2.0" (5.3 cm) high; base determines diameter. - B300-6: 6.1" (15.6 cm) diameter. DN-60980:A • 4/23/18 - Page 1 of 3 —B501: 4 (10.2 cm) diameter. Fora complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g). Operating temperature range: H365, H365R Series: —20°C to 38°C (-4°F to 100°F); H365H: —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. .9Iative humidity: 10%—.93% noncondensing. Thermal ratings: fixed-temperature set point 57°C (135°F), rate-of- rise detection 8.3°C (15°F) per minute, high temperature heat 88°C (190°F). Mounting: B300-6(A) flanged base, included. See "Product Line Information: Intelligent Bases," if using a dif- ferent base. Fixed-temperature setpoint: 135°F (57°C) for the NH-200 and NH- 200R; 190°F (88°C) for the NH-200H. Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). Max current: 4.5 mA @ 24 VDC ('ON"). Listings and Approvals Listings and approvals below apply to the NH-200(A) Series detec- tors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listing: S2101 'FM Approved CSFM: 7270-0028:0502 Product Line Information NOTE: "-IV "suffix indicates CLIP and FiashScandevice. NH-200: White, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. NH-200-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. NH-200R: White, low-profile intelligent rate-of-rise thermal sensor, B300-6 base included. NH-200R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, B300-6 base included. NH-200H: White, low-profile intelligent 190°F fixed thermal sensor, B300-6 base included. NH-200HT-IV: Ivory, low-profile intelligent 190°F thermal sensor, B300-6 base included. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6: Same as 13300-3, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of 13300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WII: White, isolator detector base. (CSFM: 7300- 1653:0216) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as 6200S-WH, ULC listing. B200SA-IV: Same as 13200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. DN-60980:A • 4/23/18 — Page 2 of 3 TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. FireWarden®, Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. NOTIFIER® and FireWarden® are registered trademarks of Honeywell Interna- tional Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this This document is not intended to be used for installation purposes. S o 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I ___________________ All specifications are subject to change without notice. u lb I I 1 J ENUNfEIlINC & MANOFAClUIlING QUALITY SYST EMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3d 3— DN-60980:A • 4/23/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0502 . Page 1 of I CATEGORY: 7270 - HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FST-951, FST-951H, NH-200, NH-200H (fixed temperature) and FST-951R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-951 and NH-200 (fixed temperature): 135°F. Models FST-951Hand NH-200H (fixed temperature): 190°F. Models FST-951 R, NH-200R (fixed temperature with rate of rise): 135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and ma manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM No. 7300-0028:173): System Sensor bases 13501, B21OLP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109); 13224131, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev 02-14-18 gt This listing .is. based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6999:E NOTIFIER® by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifiers FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and t pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input --'-- devices. * " Monitor Modules NMM-1 00(A), NMM..1 OOP(A), NZM.1 00(A), and NDM.100(A) for FireWarden Series NMM-IOOP(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75' (6.985 cm) W x 0.65' (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM.100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 —99 on FireWarden-100- 2, 01 —50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used NMM-100(A) (Type H) to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 i.JA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. - Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. DNI-6999:E• 07/30/2015 - Page 1 014 Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01-99 on FireWarden-100-2, 01 - 50 on FireWarden-50. 1415 0 1 ADDRESS 0 1 I 13 2 2 1o\ J5 Co ___ 9 87 6 8 76 TENS ONES o -J iu Lx: ) >- 1I co The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-IOOP(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6(15.24cm) minimum. NZM.1 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. ° High noise (EMF/RFI) immunity. ° SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address:, 01 - 99 on FireWarden- 100-2, 01 — SOon FireWarden-50. LED flashes during normal operation. ° LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and I LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals TIO and T11): ° DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noricondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DN-6999:E • 07/30/2015 NDM.100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class 8) /DC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-1 00(A) is set to address 26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100). MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-IOOP(A): Monitor module, miniature. NZM-1 00(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:E • 07/30/2015 - Page 3 of 4 Notifier® and FireWarden® are registered trademarks and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9001 We try to keep our product information up-to-date and accurate. - We cannot cover all specific applications or anticipate all requirements. M&INIERING B MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: 7300-0028:0230 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..100.6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 59 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-60383:A2 NC-1 OOR(A) Relay Module for (a NOTIFIER® FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FlER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include tlwo rotary switches for direct-dial entry of address setting The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. 0jt NC-i OOR(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (LIR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 1 0.5 A dn-60383:A2 "06/17/10 - Page 1 of 2 Agency Lisigs and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. ULIULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-i OOR: Intelligent addressable relay module. NC-i OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for installation purposes. I ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. RMVGl ERING & MANUFAC1UNG All specifications are subject to change without notice. I QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0028:0230 Page 1 of 1 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywelI.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC -i 00 control modules; and *NzM.100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires .June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire' Engineering Division dn-1271:A1 • 1-307 0 NOTIFIER® by Honeywell Conventionali rnunia Devices General - 302 Series Rate-Anticipation Heat Detectors The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8' (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings 6-125VDC 5amps 6-25VDC lamp 125 VOC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. 1271phol.jpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 1271 dia liii FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW OEVCON HERMETIC SEAL Cut-Away View dn-1271:A1 • 12/23/08 - Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-135 135°F All-Weather Vertical Mounting Note 2 below 302-AW-194 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4° outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50 x 50(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properlyspl'ced to "THW° or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2° (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is a registered trademark of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MGINEERINC & MANUFC1URINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 2012— dn-1271:A1 • 12/23/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 - HEAT DETECTOR LISTEE: Thermotech Inc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-ET or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC orVDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: L'stees name; model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division V 'SYSTEM _$ SENSOR Indoor Selectable Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant Construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate short',.-,g spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Aaencv Listinas SIGNAUNG LISTED APPROVED S5512 FM approved except 7125-03 S4010 for ALERT models 1135-1653 0503 3057383 The System Sensor L.Series ofers the most versatile and easy-to-use line of horis, strobes, and horn strobes in the industry with lower current drais and moderr. aesthetics. With white and red plastic housings, wall 3nd ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a varety of features :hat increase their application versatility while simphying installation. All devices feature a plug-in design with minimal iirusio•-t into the back box, making installations fast and foolproof whie virtually eliminating costly and time- consuming ground fajlts. To further simplify insa11ation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using fielc-selectable candela settings, automatic selection cf 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strob.3s and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4' high (1175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P. 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 Cd. AVOS8S800 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 'UL Max. Current Draw (mA DC Input RMS), 2-Wire 8-17.5 Volts 15cd Horn Strobe 30cd 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 - 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal Hiqh 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data -Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR - Temporal High 84 89 69 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AV0S86800 L-Series Dimensions 2.47 1.37 2.50 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 5'i'STEII,l 3825 Ohio Avenue • St. Charles, IL 60174 . ©2O17SylemSensoi. P Oduct spec cottons subject to change without notice. .5511 systeresensor.com Phone: 800-SENSOR2 • Fax: 630-377-6495 0, current poducI inormali00, ncludlflg the latest version at 105 data street. AVDS86801 • 03/17 SYSTI lvi 5i .rjs MOP Indoor Selectable, Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Aaencv Listinas SIGNAUNG 0 LISTED APPROVED S5512 FM approved except 7125-16530504 S4011 for ALERT models 7135-16530503 3057383, 3057072 The System Sensor L-Series offers the most versat.le anc easy-to-use line of horns, strobes, and horn strobes in trie industry with lower current draws and modern aesthetics. With whi:e an red plastic housings, standard and compact devices, and plan FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn s:robes include a variety of features that increase their applicaticn versatility while simplifying installation. All devices feature plug-in des gns with minimal intrusion into the back box, making insfallatc•ns fast and foolproof while virtually eliminating costly and time-ccnsuming ground faults. To further simplify installation and protect devices from ccnstruction damage, the L-Series utilizes a universal mounting plate fr all models with an onboard shorti-ig spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wioe range of application requirements using field-selectable cardela seltinçs, automatic selection of 12- or 24-volt operation, and a ro:arys'Aitcl for horn tones with two volume selections. AV0S863.00 • 2r.2I2048 • Poga 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/a-inch back box, 4 x 4 x 1112-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30,75,95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply, Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 41V16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91" D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46W x 1.91" D (133mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25D(143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D(133mm L x 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AV0S865.05 • 2122/2018 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 - Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 thuMax. a lIHorn Fl: itt:IIl 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 -- 162 196 245 Temporal Low - 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lK Temporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High,-.j;; 99 162 69 90 135 157 175 208 261 3:1KNbn-TemooralLow 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal, Low 76 84 84 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVD5865.05 • 2/22/2018 . Page 3 32 mm A0549.O0 Horn A0554-01 Wall Wall Surface Mount Back Box SBBRLISBBWL '- 4.70" (11.94 cm) 1.91" (4.85 cm) 1.25" (3.18 mm) 5.67" MI (14.4 cm) Strobe, Horn Strobe A0550.00 L-Series Dimensions 1,911 a— 3.46" 48,5mm 346" $8 111111 1.25 —3.57"— - —1.55" 88 min - 125" 32 min (9.1 cm) (3.9 cm) 32 mm _________ F1 T r-1? - " '. ______________ _ 5,38" ( (13.7 cm) 133.9 mm 133.9mm 111:111:9:1 0 L ___ I _ 2 - A0548.00 A0547.00 A0557-O0 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 )i)s act Horn Strobe, White P2RL-P 2-Wir .e, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Model Horns* Description HRL* Horn, Red HWL* Horn, White HGRL* Compact Horn, Red HGWL* Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. "Horn-only models are listed for wall or ceiling use. 3825 Ohio Avenue • St. Charles, IL 60174 @2Ot8SyotemSensor. SYSTEM Phone. 800-SENSOR2 • Fax: 630-377-6495 ProduCt speciticu os current product information, Including the latest VOtOtOS of 445 data sheet. SENSOR' toos subject to change nithout notice. Vthit systemsensur.Conl www.systemsensor.com AvDS865-05 • 222I2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135— AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc..3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, teilir,g Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test res'$s and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110,115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Aaencv Listinas SIGNALING ®,. USTED IVIEA 7300-1653:187 (outdoor Strobes) S4011 (chimes, horn strobes, horns) APPROVED approved 7125-1653 188 (horn strobes, Chime strobes) S3593 (outdoor and alert strobes) 3023572 ME5452-05-E 7135-1653:189 (horns, Chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. Wth wnite or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtjally any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F. Like the entire SpectrAlert Advance line, ou:doo: horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices t: meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applicatiois:This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can Verify pc-per wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all 3pectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastc back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3A-inch top and oottom conduit entries and 3,4-inch knock-outs at the back. A screw-in NPT plLg wi:h an 0-ring gasket for a watertight seal is included wi:h each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. -Physical/ElectricalI.1THTllr.ia. Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6-L x 4.7W x 2.5D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7W x 1.3'D(142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7'L x 5.1"W x 2.0D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15175 cd. AVDSOI2Q1 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15175 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 NA NA NA NA NA NA NA NA 228 246 281 286 207 220 251 258 Coded Coded Medium 44 Low 40 51 56 46 52 69 50 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 8-17.5 Volts 15 15175 Strobe, Standard 16-33 Volts 15 Candela Range (15-115 15/75 30 cd) 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw, W DC Input TiARMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. -Switch Horn Tones and Sound Output Data -Horn and-Horn Strobe Output (dBA) 8-17.5 16-33 Qn"nef Volts Volts 24-Volt Nominal Reverberant Anechoic Strobe Output (cd) Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 15O..____________________ 177 .177 185 185 Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low s 75 81 81 88 84 96 92 Temporal 71 Coded High 82 82 88 88 93 92 101 101 81 Coded Medium 78 78 85 85 90 90 97 98 91 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVD020 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information 1111YINNITI Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P, t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 .. ©2Or2 system Sensor. Product specrlrcotorrs subject to change wi/tout notice. visit systernsensor.com for current p oduct ntormatiofl, Including Use latest vernon of NS data street. 5EltJ5oR Phone: 800-SENSOR2 • Fax: 630-377-6495 evos01201 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 - Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division If ___~ SYSTEM '~ 4 SENSOR Selectable-Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrAlertO Advance audible visible notification products are rich with features guaranteed to cut installation times hd maximize profits. Features 520 Hz ± 10% square wave tone Plug-in design with minimal intrusion into the back box Tamper-resistant construction Field-selectable candela settings on wall units: 135, 150, 177, and 185 Rotary switch for low frequency sounder tone Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting :S S or The SpectrAlel Advance series offers the most versatile and easy-to-use I ne of low frequency sounder and low frequency sounder strobes ii the indistry. With white and red plastic housings, dual listed for wal anc •;ei:ing mounting, SpectrAlert Advrice can meet virtually any application requirement. The wall-:mount low lrec.uency sounder, and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that reuie a low frequency notification appiance that operales within frequency range of 520 Hz ± 10% and is of a square wave lore. Like the ertire SpectrAlert Advance product lire they incluc 3 a variety of features that increase their application, versatility while simplifying i-rsa'lation. All devices feature plug-in designs with rrinimal intru3ion into the back box, making installatiors fast and foolproof white virtually eliminating costly and time-consuming ground faults. To furtner simplify installation and protect devices from co,istruction damage. SpectrAl ert Advance utilizes a universal mountilg plate with an onboard Eherti ng sping, so installers can test wiring - continuity before he cevice is installed. Installers can also easily adapt devices to a suit a wide raflge of application requiremems using field-selectable candela se:tings, Agency Listings automatio selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING ®MEA LISTED APPROVED approved S4011 (sounder) 3047563 M6A452.05.E 7135.16535223 05512 (strobes) 7125.16535224 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads 'low frequency sounder" Low Frequency Sounder Ti ie low frequency sounder shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync'CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17,5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 X 411/16 X 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 OC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/RNR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162mmLx 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm Lx 120 mm x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm Lx 120 mm x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data Kul Currentilraw (MA 6111b) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded Hiqh 292 388 153 205 III. x. CurrentiDrawii Frequency Sounder Strobe,RangeI11 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 rnnfininivq 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR -DC FWR DC FWR Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 qt Coded 80 80 80 80 -80 80 90 90 Sounder ratings provided are for continuous voltage as provided by the NAC SpectrAlert Advance Dimensions 'uI 4.7 in. I 6.4 in. Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red. P2WH-LF 2-Wire Low Frequency Sounder Strobe, High Cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White - - TR-HS Trim Ring, Wall, Red Notes: High Cd" refers to strobes that include 135, 150, 177, and 185 candela settings. Sv'7Elv7 3825 Ohio Avenue • St. Charles, IL 60174 52015 System Sensor. to, current product into,maon, Including Ore latest versIonal this data sheet. ._$ SEIVSOR Phone. 800-SENSOR2 • Fax: 630-377-6495 Product specihcatlons subiect to change wdlroat notice.tasit systonlsensor.com www.systemsensor.com AVOS16404 • I/Is C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0223 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models HR-LF and HW-LF horns. Intended for indoor use and suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal. *These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to manufacturers Installation Manual for details. *Rev 07-22-14 gt This Iistiig Js based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division