HomeMy WebLinkAbout2662 GATEWAY RD; BLDG C; FPC2018-0132; Permitrc ity of PERMIT REPORT Carl sb ad Print Date: 09/29/2021 Permit No: FPC2018-0132 Job Address: 2662 GATEWAY RD, CARLSBAD, CA 92009-1776 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2132621900 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fire Sprinklers Applied: 05/04/2018 Issued: 05/30/2018 DEV12023 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: THE SQUARE AT UPTOWN BRESSI -BUILDING C -SPRINKLER (94 HEADS) Applicant: FPContractor: LINDLEY FIRE PROTECTION LINDLEY FIRE PROTECTION CO INC-DO NOT JAVIER MEJIA USE 2220 E VIA BURTON 1109 N ARMANDO ST ANAHEIM, CA 92806-1221 ANAHEIM, CA 92806-2609 (714) 984-4150 (714) 535-5761 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 Total Fees: $832.00 Total Payments To Date: $832.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008L7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ECS Ejector Automatic Air Vent (PAV-W) RIMB Specifications Stock Number: PAV-W PAV-WS (Supervised) Service Pressure: Up to 175 PSIG System Connection: 1" NPT Male Temperature Range: 40°F to 120°F (4.5°C to 49°C) Dimensions: 14"(L) X 7"(D) X 7"(H) Weight: 8 Lbs Clear Height: 5" Patented redundant float design eliminates piping to a drain Support Hanger Not Required U.S. Pat. No. 8,636,023 General Description The ECS Ejector Automatic Air Vent (PAV-W/WS) is a device that provides automatic venting of trapped air in wet pipe fire sprinkler systems. As a fire sprinkler system is filled with water, trapped air migrates to the high point of the system near the vent installation location which allows for trapped air to be vented. Trapped air contains oxygen which is the primary cause of corrosion in fire sprinkler systems. Corrosion in wet pipe fire sprinkler systems is directly proportional to the amount of oxygen trapped within the system piping, so a reduction in trapped air will in turn reduce the internal corrosion activity of the fire sprinkler system. Venting the trapped air in a wet pipe sprinkler system can also decrease water delivery time and reduce false water flow alarms. The ECS Ejector Automatic Air Vent must be installed as shown on the engineering design documents, if a location is not provided install the vent at an accessible high point on the fire sprinkler system remote from the system riser where gas can be vented and at a location that the pressure gauge provided for visual monitoring can be viewed from directly below. The PAV-W/WS is also equipped with brass components that allows the device to be installed in areas subject to external corrosion. The float mechanism on the ECS Ejector Automatic Air Vent will automatically close when water reaches the vent and the redundant design eliminates the need to plumb the PAV-W/WS to drain. If the primary air vent valve allows any significant amount of water to leak past the second air vent valve will close preventing water from discharging and provide a system pressure reading on the pressure gauge. This condition will be an indication that the primary automatic gas vent valve has failed and requires service or replacement. The pressure gauge is designed to be visible from the floor below the ECS Ejector Automatic Air Vent from a distance of approximately 30 feet. There are two available models of the ECS Ejector Automatic Air Vent: the PAV-W and the PAV-WS. The units both operate as described previously, but the PAV-WS includes a wiring connection to a monitoring circuit. A single contact rated 24VAC/DC @ 2A for electronic monitoring with an end of line resistor (EOLR) must be installed according to the wiring diagram in Figure 1 to electronically monitor the PAV-WS. A notification from the PAV-WS indicates that the pressure gauge on the bottom of the vent assembly has a system pressure reading due to a failure of the primary float valve which renders the ECS Ejector Automatic Air Vent inoperable. Engineered Corrosion Solutions• 11336 Lackland RoadS St. Louis, MO 63146 Phone 1-314-432-1377• www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 1 Installation Instructions Maintenance Instructions 1 The ECS Ejector Automatic Air Vent is equipped with an isolation ball valve to be connected to the fire sprinkler system. Once the PAV-W/WS has been assembled at the provided union (see Figure 1), the contractor shall install a 1" outlet (welded or mechanical) to connect the vent assembly to the sprinkler system. 2 Install the PAV-W/WS vent assembly at the location provided by the engineering design documents in a level position at an accessible high point on the sprinkler system where trapped gas can be vented. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. 3 When electronic supervision is specified the PAV-WS must be utilized instead of the PAV-W (see Figure 1) and an addressable monitor module with an end of line resistor must be provided in accordance with NFPA 72. 4 Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. Inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. NOTE: Patented redundant float design eliminates piping the PAV-W to a drain FIGURE 1 - Wiring Diagram INSTALLATION NOTES: If Monitored By The Building Fire Alarm System, Provide One Addressable Monitoring Module To Monitor The Ejector Automatic Air Vent. connect The Ejector Automatic Air Vent To The Addressable Monitor- ing Module. Supervise The Circuit Using An End-Of -Line (E.O.L.) Resistor In Accordance With NFPA 72. Add, e,nble D*, The ECS Ejector Automatic Air Vent shall be inspected annually at minimum. While isolation ball valve is in the open position check for air/water leaks. Check the pressure gauge on the bottom of the vent assembly for a system pressure reading. If a system pressure reading is detected the primary vent valve may require service or replacement. While isolation ball valve is in the closed position the inspection must check for blockage in the "Y" strainer and the discharge orifice. Operating Instructions Once the fire sprinkler system has been hydrostatically tested, open the isolation ball valve on the PAV-W. Trapped gas should be expected to immediately vent from the device if the system has been re-filled with water. The isolation ball valve shall remain in the open position to allow for venting of any additional trapped gas remaining in the system that may migrate to the vent location. Water traps that would restrict operation of the ECS Ejector Automatic Air Vent can be cleared by closing the isolation ball valve and removing the "Y" strainer plug. Once the water trap has been removed, replace the "Y" strainer plug and reopen the isolation ball valve. Gas Vent Valve Replacement Plumbing the PAV-W/WS to drain is not required. Occasionally during venting operations a small amount of water may leak past the primary gas vent valve and collect in the intermediate plumbing. This is considered normal and not a failure of the valve. However, if inspection reveals a system pressure reading then the primary vent valve may require replacement. Please contact Engineered Corrosion Solutions for replacement parts and instructions. Engineered Corrosion Solutions 11336 Lackland Road• St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 2 1" Connection to Sprinkler System must NOTE: Patented redundant float design eliminates piping vent to drain. A 11,3, eee.w LE ®rrôkiui L\/ Sfis ciö75si5ñcöWff81. E1JECTOR1 Aut3matiilen1 diTi - forfirikI! Figure 2 - ECS Ejector Automatic Air Vent Outline Drawing Primary and Seconda Gas Vent Valves "Y" Strair Pressure Gauge Figure 3 - ECS Ejector Automatic Air Vent Installed on Sprinkler System NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. Engineered Corrosion Solutions 11336 Lackland Road • St. Louis, M063146- Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 Engineered Corrosion SolutionsT M Complete Corrosion Control. F~TF'Aktl"~Mv - Fire Protection by Computer Design LINDLEY FIRE PROTECTION 2220 E. VIA BURTON ANAHEIM, CA 92806 714-535-5761 Job Name : THE SQUARE AT BRESSI RANCH BLDG C Building : C Location : 2662 GATEWAY ROAD System : 1 Contract : A3001 Data File : The Square at Bressi Ranch Bldg C.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 LINDLEY FIRE PROTECTION Page 1 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Hydraulic Design Information Sheet Name - THE SQUARE AT BRESSI RANCH BLDG C Date - 4-27-18 Location - 2662 GATEWAY ROAD Building - C System No. - 1 Contractor - CSI CONTRUCTION COMPANY Contract No. - A3001 Calculated By - T. OMORI Drawing No. - FPC2.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 181 -8" Occupancy - RETAIL (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. NFPA 231 ( ) NFPA 231C Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (X) Wet Make GLOBE Area Per Sprinkler - 120 ( ) Dry Model GL Elevation at Highest Outlet - 17'-8" ( ) Deluge Size 1/2 Hose Allowance - Inside - 100 ( ) Preaction K-Factor 5.6 Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 Hose Allowance - Outside - 150 Note Calculation Flow Required Summary C-Factor Used: - 469.21 Press Required - 120 Overhead 83.351 BOR 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 3-9-18 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 129 @ Press - R Residual Press - 20 Elev. - Well Flow - 8000 Proof Flow S Elevation - U P Location - EL FUERTE STREET NORTH OF GATEWAY ROAD P L Source of Information - CITY OF CARSBAD Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 S Y S T E M D E S I G N Water Supply Curve C LINDLEY FIRE PROTECTION Page 2 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 City Water Supply: Demand: Cl - Static Pressure : 129 Dl - Elevation : 7.652 C2 - Residual Pressure: 20 D2 - System Flow : 469.211 C2 - Residual Flow : 8000 D2 - System Pressure : 90.623 Hose ( Demand) : 250 D3 - System Demand :719.211 Safety Margin : 37.113 150 140 Cl 130 p 12 R 110 E100 s 90 D s80 u 70 R 60 E5° 40 --- 30 - 2 C 20 [[JeErc!e~i~tqnde~ 10 10002000 3000 4000 5000 6000 7000 8000 9000 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram LINDLEY FIRE PROTECTION THE SQUARE AT BRESSI RANCH BLDG C 24 AO AOl 16 AO2- A03 Page 3 Date 4-27-18 29.2 88 149.8 I 4-2 -3 +-4 5 6 -7 58.5 118.3 183.4 23.9 47.9 8 -9 4-10 +- 11 47.9 24 48.1 122.1 179.1 12 - 13 14 +-. II +- 15 - 16 17 +- 18 #- 19 48.1 96 149.5 211.6 37 20 #- 21 +-. 22 74.2 183.4 469.2 469.2 569.2 569.2 215.6 215.6 215.6 7 - 19 - 22 - 23 - 24 - TRC#. BRC- Cl - C2 - C3 - UG&- UG74- UG6- UG5 UG44- UG9 395 469.2 469.2 569.2 569.2 215.6 215.6 503.7 UG&- UG9#- CON 719.2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary LINDLEY FIRE PROTECTION Page 4 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Fitting Legend Abbrev. Name % 3/4 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 .25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD LINDLEY FIRE PROTECTION Page 5 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. AO 17.667 5.6 18.37 na 24.0 0.2 120 7.0 AOl 17.667 20.65 na A02 17.667 5.6 8.16 na 16.0 0.2 80 7.0 A03 17.667 . 9.24 na 1 17.667 K= K@AO1 30.52 na 29.18 2 17.667 K= K @ AO1 30.74 na 29.28 3 17.667 K= K @ AO1 31.39 na 29.59 4 17.667 K= K @ AO1 32.76 na 30.23 5 17.667 K= K@AO1 35.73 na 31.57 6 17.667 K= K @ AO1 40.32 na 33.53 8 17.667 K= K @ A03 20.62 na 23.9 9 17.667 K= K @ A03 20.78 na 23.99 10 17.667 21.11 na 12 17.667 K= K @ AO1 20.65 na 24.0 13 17.667 K= K @ AO1 20.81 na 24.09 14 17.667 21.14 na 11 17.667 21.66 na 15 17.667 K= K@AO1 24.41 na 26.1 16 17.667 K= K @ AO1 26.93 na 27.41 17 17.667 K= K@AO1 31.5 na 29.64 18 17.667 K= K@AO1 37.89 na 32.51 20 17.667 K= K@AO1 49.17 na 37.03 21 . 17.667 K = K@AO1 49.51 na 37.16 7 17.667 49.45 na 19 17.667 49.79 na 22 17.667 51.23 na 23 17.667 59.5 na 24 17.667 69.33 na TRC 17.667 72.13 na BRC 0.0 83.35 na 100.0 Cl 0.0 83.62 na C2 0.0 85.33 na C3 0.0 89.42 na UG8 0.0 90.09 na 150.0 UG7 0.0 90.14 na UG6 0.0 90.22 na UG5 0.0 90.27 na UG4 0.0 90.39 na UG9 0.0 90.48 na CON 0.0 90.62 na The maximum velocity is 28.56 and it occurs in the pipe between nodes 18 and 19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 6 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn AO 24.00 1.087 2T 11.892 3.000 18.367 K Factor 5.60 to 120.0 0.0 11.892 0.0 AOl 24.0 0.1534 0.0 14.892 2.284 Vel = 8.30 0.0 24.00 20.651 K Factor = 5.28 A02 16.00 1.087 2T 11.892 3.000 8.163 K Factor =5.60 to 120.0 0.0 11.892 0.0 A03 16.0 0.0725 0.0 14.892 1.079 Vel = 5.53 0.0 16.00 9.242 K Factor = 5.26 1 29.18 1.74 0.0 10.000 30.519 K Factor @ node AOl to 120.0 0.0 0.0 0.0 2 29.18 0.0223 0.0 10.000 0.223 Vel = 3.94 2 29.28 1.74 0.0 8.000 30.742 K Factor @ node AOl to 120.0 0.0 0.0 0.0 3 58.46 0.0805 0.0 8.000 0.644 Vel = 7.89 3 29.59 1.74 0.0 8.000 31.386 K Factor © node AOl to 120.0 0.0 0.0 0.0 4 88.05 0.1718 0.0 8.000 1.374 Vel = 11.88 4 30.23 1.74 0.0 10.000 32.760 K Factor @ node AOl to 120.0 0.0 0.0 0.0 5 118.28 0.2965 0.0 10.000 2.965 Vel = 15.96 5 31.56 1.74 0.0 10.000 35.725 K Factor @ node AOl to 120.0 0.0 0.0 0.0 6 149.84 0.4593 0.0 10.000 4.593 Vel = 20.22 6 33.54 1.74 T 11.677 2.000 40.318 K Factor @ node AOl to 120.0 0.0 11.677 0.0 7 183.38 0.6674 0.0 13.677 9.128 Vel = 24.74 0.0 183.38 49.446 K Factor= 26.08 8 23.90 1.74 0.0 10.000 20.624 K Factor @ node A03 to 120.0 0.0 0.0 0.0 9 23.9 0.0153 0.0 10.000 0.153 Vel = 3.22 9 23.99 1.74 0.0 6.000 20.777 K Factor @ node A03 to 120.0 0.0 0.0 0.0 10 47.89 0.0558 0.0 6.000 0.335 Vel = 6.46 10 0.0 1.74 E 5.838 4.000 21.112 to 120.0 0.0 5.838 0.0 11 47.89 0.0556 0.0 9.838 0.547 Vel = 6.46 0.0 47.89 21.659 KFactor= 10.29 12 24.00 1.74 0.0 10.000 20.651 K Factor@ node AOl to 120.0 0.0 0.0 0.0 13 24.0 0.0155 0.0 10.000 0.155 Vel = 3.24 13 24.09 1.74 0.0 6.000 20.806 K Factor @ node AOl to 120.0 0.0 0.0 0.0 14 48.09 0.0560 0.0 6.000 0.336 Vel = 6.49 14 0.0 1.74 E 5.838 3.375 21.142 to 120.0 0.0 5.838 0.0 11 48.09 0.0561 0.0 9.213 0.517 Vel = 6.49 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 7 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 11 47.89 1.74 1 11.677 2.000 21.659 to 120.0 0.0 11.677 0.0 15 95.98 0.2015 0.0 13.677 2.756 Vel = 12.95 15 26.10 1.74 0.0 8.000 24.415 K Factor @ node AOl to 120.0 0.0 0.0 0.0 16 122.08 0.3144 0.0 8.000 2.515 Vel = 16.47 16 27.41 1.74 0.0 10.000 26.930 K Factor @ node AOl to 120.0 0.0 0.0 0.0 17 149.49 0.4573 0.0 10.000 4.573 Vel = 20.17 17 29.64 1.74 0.0 10.000 31.503 K Factor @ node AOl to 120.0 0.0 0.0 0.0 18 179.13 0.6390 0.0 10.000 6.390 VeI= 24.17 18 32.51 1.74 T 11.677 2.000 37.893 K Factor @ node AOl to 120.0 0.0 11.677 0.0 19 211.64 0.8700 0.0 13.677 11.899 Vel = 28.56 0.0 211.64 49.792 K Factor= 29.99 20 37.03 1.74 0.0 10.000 49.168 K Factor @ node AOl to 120.0 0.0 0.0 0.0 21 37.03 0.0346 0.0 10.000 0.346 Vel = 5.00 21 37.17 1.74 T 11.677 2.000 49.514 K Factor @ node AOl to 120.0 0.0 11.677 0.0 22 74.2 0.1251 0.0 13.677 1.711 Vel = 10.01 0.0 74.20 51.225 KFactor= 10.37 7 183.38 3.316 0.0 12.000 49.446 to 120.0 0.0 0.0 0.0 19 183.38 0.0288 0.0 12.000 0.346 Vel = 6.81 19 211.64 3.316 0.0 12.000 49.792 to 120.0 0.0 0.0 0.0 22 395.02 0.1194 0.0 12.000 1.433 Vel = 14.68 22 74.19 3.316 T 21.903 28.500 51.225 to 120.0 0.0 21.903 0.0 23 469.21 0.1642 0.0 50.403 8.275 Vel = 17.43 23 0.0 3.316 E 10.221 49.667 59.500 to 120.0 0.0 10.221 0.0 24 469.21 0.1642 0.0 59.888 9.831 Vel = 17.43 24 0.0 3.316 E 10.221 6.833 69.331 to 120.0 0.0 10.221 0.0 TRC 469.21 0.1642 0.0 17.054 2.800 Vel = 17.43 TRC 0.0 4.316 Fsp 0.0 12.500 72.131 to 120.0 0.0 0.0 10.652 * * Fixed Loss = 3 BRC 469.21 0.0454 0.0 12.500 0.568 Vel = 10.29 BRC 100.00 6.357 E 17.603 10.000 83.351 Qa = 100 to 120.0 0.0 17.603 0.0 Cl 569.21 0.0099 0.0 27.603 0.273 Vel = 5.75 Cl 0.0 6.09 4E 86.332 126.000 83.624 to 150.0 0.0 86.332 0.0 C2 569.21 0.0080 0.0 212.332 1.708 Vel = 6.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 8 THE SQUARE AT BRESSI RANCH BLDG C Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11C.,or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C2 0.0 6.16 Zif 0.0 10.000 85.332 to 140.0 0.0 0.0 4.000 * * Fixed Loss 4 C3 569.21 0.0086 0.0 10.000 0.086 Vel = 6.13 C3 0.0 6.09 G 4.625 11.000 89.418 to 150.0 T 46.249 72.457 0.0 UG8 569.21 0.0081 E 21.583 83.457 0.672 Vel = 6.27 UG8 -353.65 7.98 2F 27.183 124.500 90.090 Qa = 150 to 150.0 0.0 27.182 0.0 UG7 215.56 0.0004 0.0 151.682 0.054 Vel = 1.38 UG7 0.0 7.98 2F 27.183 187.000 90.144 to 150.0 0.0 27.182 0.0 UG6 215.56 0.0004 0.0 214.182 0.077 Vel = 1.38 UG6 0.0 7.98 3F 40.774 94.000 90.221 to 150.0 0.0 40.774 0.0 UG5 215.56 0.0004 0.0 134.774 0.048 Vel = 1.38 UG5 0.0 7.98 E 27.183 234.500 90.269 to 150.0 F 13.591 99.669 0.0 UG4 215.56 0.0004 G 6.041 334.169 0.119 Vel= 1.38 T 52.855 UG4 0.0 7.98 F 13.591 233.000 90.388 to 150.0 2G 12.081 25.674 0.0 UG9 215.56 0.0004 0.0 258.674 0.093 Vel = 1.38 0.0 215.56 90.481 K Factor= 22.66 UG8 503.65 7.98 F 13.591 155.000 90.090 to 150.0 C 6.041 72.487 0.0 UG9 503.65 0.0017 T 52.855 227.487 0.391 Vel = 3.23 UG9 215.56 11.65 2F 34.882 138.000 90.481 to 150.0 2G 16.1 131.481 0.0 CON 719.21 0.0005 T 80.498 269.481 0.142 Vel = 2.16 0.0 719.21 90.623 K Factor= 75.55 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 No. 138 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue — Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER SR#: PROJECT NAME: The Square at Bressi Ranch (Assigned upon plan submittal) PROJECT ADDRESS: CITY: ______________________________ Carlsbad PHONE:( ) Lindley Fire FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: .402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet LIEoijjEReacline 1PSI Total Flow: 8,000 GPM Residual Pressure 110 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jenrjfer R Mael P E Eng. Lic. No. (if applicable):C69606 Signature:________________________________________ Title/Org(oiect Manager Date: 03/09/2018 I : LS 7/ 1W I 12 I PL oil, 12~- >. 2.L _9 F 8 I jERfl'- N 8- SC D1A to CO T. N H1W to CMD I tiI I 9 ES-F-LF876V Job Name Job Location Engineer Approval MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/2" - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal N-Pattern" Installations Vertical-Up Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4" Backflow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Contractor Approval Contractor's P.O. No Representative - Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWINA Standard C510. The auxiliary bypass line contains a %"x3/4" Water Meter that complies with ANSI/AW\NA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWINA Standard C51 0 flow and pressure loss performance parameters. NOTICE I The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. i'iS1tti Inquire with governing authorities for local installation requirements Detect Potential Underground Water Leaks "The wetted surface of this product contacted by consumable Detect Unauthorized Water Usage water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A VIIATTS Brand Options — Suffix OSY: ULJFM Approved OS&Y Gate Valves [ANSI/AWWA 0515 Compliant] CFM: Totalizing Cubic feet/mm %"x 3/4" Water Meter [ANSI! AWWA 0700 Compliant] GPM: Totalizing Gallons/mm %"x 3/4" Water Meter [ANSI! AWWA 0700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4' LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-0SY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer. FDA Approved [ASME B16.1 Class 125 & AWWA Class D Flange] Series 611 Valve Setter: MJ x MJ - Mechanical Joint x Mechanical Joint [AWWA C111!A21.11] MJ x FL - Mechanical Joint x Flange (AWWA C111!A21.11; ASME B16.1 Class 125/AWWA Class D Flange] FL x FL - Flange x Flange [ASME B16.1 Class 125 & AWWA Class D Flange] Materials Below is a general materials list of the Model LF876V. All assemblies size 21/2" through 8" is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA 0550-90 Shutoff Valves: OSY resilient wedge gate valve AWNA 0515 (UL/FM) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc Silicone Spring: Stainless Steel Clamp: AWWA 0606 Approvals — Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [F000HR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard 0510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Flange **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2" - 8") - Approved by F000HR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 21/2 —8") - Approved by F000HR-USC, ASSE, cULus, FM, IAPMO/cUPC $Slp1 c>. @ <~(~M> C us C ®® Approved 1048 864.5 Pressure — Temperature Max. Working Pressure: 175psi (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Hydrostatic Safety Pressure: 700p5i (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Sb Dimensions - Weights Size: 21/2" - 8" Below are the nominal dimensions and physical weights for the Model LF876V size 21/2' through 8. Allowances must be made for normal manufacturing tolerances. Please visit our website to download a copy of this product's installation instructions, or contact your local FEBCO Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V [ SIZE (DN) DIMENSIONS -- - -- WEISHT1 in. mm in. A. mm in. B mm in. C vim in. 0 mm E in. mm F in. mm G in. mm in. H mm in. mm J in. - mm in. mm in. L mm OSY lbs. kg. 21/2 65 291h 740 121h 318 61/4 159 251/4 642 171h 445 13,6 346 271/4 692 51/2 140 11'/s 283 3½ 89 163A 416 11½ 292 216 98 3 80 291A 740 121h 318 61/4 159 253/4 654 173/4 451 141A 359 281/4 718 51h 140 11½ 283 33/4 95 221/4 565 11½ 292 242 110 4 100 311/8 791 14 356 7 178 27/4 705 183/4 476 151h 394 31 787 6 152 111/8 283 4½ 114 231/4 591 13 330 347 157 6 150 353/4 908 16 406 8 203 323/4 831 221h 562 18½ 473 37¼ 946 7¼ 184 121h 316 51h 140 30½ 765 13 330 529 240 8 200 403/4 10351181/2 470 91/4 235 363/4 933 251h 638 20/4 527 41½ 1054 1 8½ 216 14 356 63/4 172 1 373/4 959 141h 368 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backf low Assemblies with specified Gate Valves 6" 1F876V psi Service Flow Rated Flow Iii Rated Flow 18 16 14 I 12 I 10 I _i q : 2 I I I 0 I I I I 0 200 400 757 600 800 2271 7.5 1000 1200 3785 11.4 1400 1600 gpm 5300 1pm 17.0 fps 81 1F876V psi Service Flow Rated Flow 6L Rated Flew 18 16 14 12 10 5 8 0 400 800 1200 1600 2000 2400 gpm 7514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fp5 Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. ANA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than iOfps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern 2½" LF876V psi Service Flow Rated Flow U1 Rated Flow 22 20 I I 18 I - 16 I I I 14 I H 0 25 50 75 284 311 1F876V psi tOO 125 150 175 200 225 250 275 300 325 350gpm 568 852 1136 1pm 7.5 14.7 22.0 fps Service Flow Rated Flaw UL Rated Flow 22 20 I I I 18 I I 16 I I 14 I 5 12 10 'i)t 4 I I 2 I 0 I I 0 50 100 379 4" 1F876V psi 150 200 757 7.5 Service Flaw 250 300 350 1136 14.5 Rated Flow 400 450 500 gpm 1514 1pm flo fps *UL Rated Flow 18 16 I I 14 12 I I 10 : 6 I I t 2 0 I I I I I I 100 200 300 379 1136 7.5 400 500 600 1893 12.8 700 800gpm 2650 1pm 19.1 fps Pipe Support (furnished by customer) for valve weight only. Vertical Orientation 7-Pattern" Flow Curve Z Standard Orientation 'N-Pattern" Flow Curve N A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBCOonhine.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBC0online.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonhine.com 0 2017 FEBCO w i;M LINDLEY LINDLEY FIRE PROTECTION Co. 2220 E. VIA BURTON ANAHEIM, CA 714-535-5761 LIC. # C16/04 NO. 713562 DATE: 4-27-18 MATERIAL SUBMITTAL FOR THE SQUARE AT BRESSI RANCH BUILDING C 2662 GATEWAY ROAD CARLSBAD, CA 1 •( •j• STANDARD RESPONSE AUTOMATIC SPRINKLERS i m GL SERIES UPRIGHT 'PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response GL Series Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is rz available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response STANDARD RESPONSE Sprinklers should be used advisedly and under the direction of UPRIGHT CONVENTIONAL approving authorities having jurisdiction. 1 The heart of Globe's GL Series sprinkler proven actuating .. assembly is is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. STANDARD RESPONSE The sprinkler and escutcheon are not factory assembled. PENDENT VERTICAL Assembly is done in the field. SIDEWALL TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C) 1 4'' 1U. 500°F (260°C) Available Upon Request Without Approvals Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) STANDARD RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C) LPC/CE HORIZONTAL Frame - bronze ' Deflector - brass • Screw - brass HORIZONTAL SIDEWALL Lodgement Wire - stainless steel . Bulb seat - copper SIDEWALL Spring - nickel alloy• Seal - teflonw Bulb - glass with glycerin solution, 5mm size Escutcheon Assembly - steel 'SPRINKLER TEMPERATURE RATIN/(LASIFI(ATIflN and CDLtDR (flflIN CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY 135F/155°F 57 C168C ORANGE/RED 100F 38°C INTERMEDIATE 175°F/200°F 79C/93°C YELLOW/GREEN 150°F 66°C HIGH 286F 141°C BLUE 225°F 107°C EXTRA HIGH 360'F 162°C MAUVE 300'F 149°C ULTRAHIGH 500°F 260°C BLACK 475'F 246°C NOV 2016 GFS-100b (Formerly A-65) 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL CULLIS LISTED FOR DEFLECTOR 4' TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. 500°F (260"C) AVAILABLE UPON REQUEST WITH NO APPROVALS. TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD' cULus FM LPC CE NYC-DOB MEA 101-92-E 135°F 155°F 175°F 200°F ""286°F "360°F (57°C) (68°C) (79°C) (93°C) (141°C) (182°C) GL2861 2.8 LH X X X X X X X x GL4261 4.2 LH X X X X X X X X UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X GL8161 8.0 ALL X X X X X X X X GL8164 8.0 ALL X X X X X X X X X X X GL2851 2.8 LH X X X X X X X X PENDENT GL4251 4.2 LH X X X X X X X X RECESSED GL5651 5.6 ALL X X X X X X X X X X X PENDENT GL8151 8.0 ALL X X X X X X X X X GL8156 8.0 ALL X X X X X X I X X. X X X VERTICAL GL5675 5.6 LH X X X X X X X X --- SIDEWALLt GL8176 8.0 LH X X X X X X X HORIZONTAL GL2870 2.8 LH X X X X X X X X SIDEWALL GL4270 4.2 LH X X X X X X X X RECESSED GL5670 5.6 LH/OH X X X X X X X X x HORIZONTAL GL56710 5.6 LH/OH X X X X X X --- --- X X SIDEWALL GL8171 8.0 LH/OH X X X X X X X --- CONVENTIONAL GL5668 5.6 LH/OH X X X X X X --- --- X X (OLD STYLE) GL8169 8.0 LH/OH X I X I X I X X X --- --- X X 'BRASS FINISH ONLY WHEN RECESSED **NO FM APPROVALS FOR RECESSED "NO FM APPROVALS OH: ORDINARY HAZARD LH: LIGHT HAZARD ALL: ALL HAZARDS STANDARD RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL S CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT(15mm) 2 1/4" (5.7cm) Factory Bronze 4.2 (60 metric) 1/2"N PT (15mm) 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2"N PT (15mm) 2 1/4" (5.7cm) White Polyester3 8.0 (115 metric) 1/2"N PT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) Wax Coated234 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL 1S2 9/16". 4WJ( COATING cULus LISTED UP TO 200°F (93°C) ONLY. 'FINISHES AVAILABLE ON SPECIAL ORDER. APPROVALS ____________ ORDERING INFORMATION SPECIFY Quantity. Model • Number Style. Orifice Thread Size Temperature• Finish desired Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"): P/N 312366/325401 (L.O.) Quantity Protective Caps - PIN 327109-CAP (Friction Fit Recessed) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 2 15/16" 0!A.-..i 2"DIkMIN. -i HOLEIN CEIUNG I 129132- 016. SE D&JCE N III 1/8" MIN. 7/8" MAX. I" MIS. 1 3/4IER " 6.921. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 GLbBE 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com NOV 2016 PRINTED U.S.A. GFS-100b (Formerly A-65) QUICK RESPONSE A UTOMA TIC SPRINKLERS FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F Frame - bronze • Deflector - brass Screw - brass Lodgement Wire - stainless steel Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL (-55°C) oSPRjNKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING I CLASSIFICATION I AVAILABLE SPRINKLER I BULB COLOR I N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135'F/155 'F 57'C;68 C ORANGE/RED 100 *F 381C I INTERMEDIATE 175F:200F 79C/93C YELLOW/GREEN 150F 66C I I HIGH 286F 141'C BLUE 225F 107CC I NOV 2016 GFS-looa (Formerly A-20) QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 21/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 1 3/4"NPT (20mm) 27/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD' cULus FM LPC CE NYC-DOB MEA 101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0* LH/OH X X X X X X X X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X --- GL2826 2.8 LH X X X X X X X TA HORIZONTAL GL4226 4.2 LH X X X X X X X GL5626 5.6 LH/OH X X X X X X X X SIDEWALLGL5627r, 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH I X I X X X X --- --- X I X --- 'SPRINKLERS SHALL BE LIMIT EL) AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. DINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • Model Number • Style S Orifice products found to be defective in material or workmanship for a Thread Size • Temperature Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 GLbBE 1-800-248-0278 www.globesprinkIer.com FIRE SPRINKUR CORPORATION NOV 2016 PRINTED U.S.A. GFS-1 00a (Formerly A-20) Fire Sprinkler Pipe Mea-F1®w and Mega-Thread Submittal Data $heet FM Approved and Fully Listed Sprinkler Pipe Wheatland's Mega-Flow steel fire sprinkler pipe is FM Approved for roll-grooved, plain-end and welded joints for wet systems; and UL, C-UL and FM Listed for use with roll-grooved, plain- end couplings and welded joints for wet, dry preaction and deluge systems. Mega-Thread is FM Approved for use in wet systems and is UL, C-UL and FM Listed for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards ASTM A795, Type E, Grade A NFPA 13 and NFPA 14 Mega-Thread is approved for standard hanger spacing Manufacturing Protocols Mega-Flow and Mega-Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega-Flow black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega-Thread is hot-dip galvanized to meet FM requirements for dry systems and is safer to weld than many zinc-coated, light-wall threadable products. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. MEGA-FLOW SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-FLOW Mega-Flow Schedule Schedule Schedule Mega-Flow Nominal Pcs./LI?t 10 40 40 wt./ft. 1% 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 1'/z 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 2½ 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 .75 1.00 8.000 10 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). MEGA-THREAD SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-THREAD Mega-Thread Schedule Mega-Thread Schedule L.W.T. Pipe Nominal Pcs./Lltt 1 1.315 1.087 1.049 1.00 1.00 .61 1.462 70 1'/a 1.660 1.416 1.380 1.00 1.00 .39 1.989 51 11/2 1.900 1.650 1.610 1.00 1.00 .31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 .25 3.094 30 Calculated using Standard (IL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C@ PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 0 MEGA-THREAD-HOT-DIP GALVANIZED MWK-e-atI15-n-diT6 e - South-1 et S aron, 161_1~6 kqS r Me owheatlndzom fWlleaOan1 Tube iNC STEEL GPC'UP SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NIPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm ibs./ft. kg/rn CRR* Lift 1'/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1'/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11,58 Is 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NIPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 11% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). @ C& <.~PPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK 0 HOT-DIP GALVANIZED tWheatland Tube P .JMC STEEL GROUP Fire Products Division of Anvil International January 2010 For the most current product/pricing information on Anvil products, pleas visit our website at www.onvilinH.con 4 MERIT [DOOR NR WncRREOM 0 T, Vj PMU VOC'UM IPUMRCON FOE I BUILDING CONNECTIONS THAT LAST i , ( C) Fo r over 150 years, Anvil has worked diligently to build a strong, vibrant tradition of making connections - from pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior customer service at all levels. We provide expertise and product solutions for a wide range of applications, from plumbing, mechanical, HVAC, industrial and fire protection to mining, oil and gas. Our comprehensive line of products includes: grooved pipe couplings, grooved and plain-end Fittings, valves, cast and malleable iron fittings, forged steel fittings, steel pipe nipples and couplings, pipe hangers and supports, channel and strut fittings, mining and oil field fittings, along with much more. As an additional benefit to our customers, Anvil offers a complete and comprehensive Design Services Analysis for mechanical equipment rooms, to help you determine the most effective and cost-efficient piping solutions for your pipe system. At Anvil, we believe that responsive and accessible customer support is what makes the difference between simply delivering products - and delivering solutions. 1/j - AI]li Weld-Miser Welding Outlet Fittings Unified DesignTM Series Merits Unified Design Series carries all important design considerations into Its entire line of welding branch outlet fittings. Merlt Weld-Miser Tee-Lets are designed and Manufactured to reduce the amount of weld required to Install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the Installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby Insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. - - —I- - On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from dam- age during shipping and handling prior to Installation as well as from weld distortion, Each outlet size 1½" and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are ULJULC Listed and FM Approved for use In the fire sprinkler systems Installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation In fire sprinkler systems, and higher pressures In other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be Installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit Weld-Miser Tee-Lets" are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify Weld-MiserTM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI 131.20.1, or 150-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® WeIdMiserTM Tee-Let® Method No. 1 Method No, 2 Specify quantity desired followed by the part Use the following system: number shown in the "dimensions" chart for the type and size of outlet desired. - Type Merit Steel Quantity Part Number Quantity * Outlet Size * Header Size * Weight End Tee-Let Material $ * Always Column "A" Insert size Sch. 10 A- Female Thread order a few of Chart consolidation Standard B - Male Thread more than from Column C - Cut Groove actually "8" of chart CJR - Roll Groove required for the lob. 1 1iVLBtar Merit -1.10 —3— Rio Pioducto OMdon dAmd kftnuftrW WeIdMiserTM TeeLet® Welding Outlet Fittings LN IVED ,piozerdalNo For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser Tee-Lets Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and manufactured to be Installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used In manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum bum-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or lSO7/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi When used In mechanical systems, maximum pressures are calculated using criteria developed for ASME B31 piping code. TEE-LET WELDED OUTLET Outlet Model FITTING (LIL VIZU — EX6032, Outlet Pipe Size (inch) FIVI APPROVAL GUIDE CHAPTER Header Pipe Size (Inch) 1 PIPE FITTINGS) Rated Pressure (psig) Tee-Let Type A (F-Threaded End) 14,3/4,1 11/4.114. 2, 2½. 3,4 ½-8 (Sch.10,40) 300 6 (EZ-Flow) ½. 4 (Sch. 5 DynaFlow) 2 4 (EZ-Flow) 2,4 Tee-Let Type C (Grooved End) 11/4.8 1¼-8 (Sch. 10, 40) 300 214-8 ½- 4 (Sch. 5, DynaFlow) Tee-Let Type C/R (Roll _Grooved _End) 11/4 -6 11/4-8 (All Schedules) 300 Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe Is 175 psi. -4- MOM -1.10 Pr. Products DvtIon ofAnvOlnternadonaj Type A Female Three TiTm. DIMENSIONS & PART NUMBERS Part Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each A B C U M NPT13SP?) In (mm) In (mm) In (mm) In frrm In (mm) Lb. (g 1002002 ¼x 114-8 0.080 6 6 101) 004 1005012 1114 - 1½ 1.063 0.700 0,500 0.171 .'U40 21.0 17.8 127 0.08 1005015 -2 1.063 0.700 0.500 0.171 ½x .10- 10 2.0 71.8 12.7 0.08 1005020 2-214 1.063 0.700 0.500 0.171 .51) 5s 270 17.8 121 0.08 1005025 214-8 1.063 0.700 0.500 0.169 63 200 2 0 178 12.7 008 1007012 1¼-1½ 1.125 0.900 0.500 0.260 .1.' 40 286 229 127 0.72 1007015 114-2 1.125 0.900 0.500 0.260 3/4 x 46 sv 28.6 22 9 172.7 012 1007020 2-2½ 1.125 0.900 0.500 0.260 j, 6s 28.6 229 12.7 1 0.12 1007025 214-8 1.125 0.900 0.500 0.256 bt 200 286 229 121 0.12 1010012 1114 - 1½ 1.250 1.145 0.500 0.331 11)0(02 .12-40 318 29.7 121 0./5 1010015 1½-2 1.250 1.145 0.500 0.331 1113015 41) .50 31.8 29.! 12.7 0.75 1010020 2-2½ 1.250 1.145 0.500 0.320 11 1002d lx ,t) 65 918 29.1 /27 0.75 1010025 214-3 1.250 1.145 0.500 0.314 111002.5 bb 80 37.8 29.1 12.1 0.14 1010030 3-4 1.250 1.145 0.500 0.309 1/1(1330 0 /1)0 F,825 31.8 29.1 72.7 0.14 1010050 5-8 1.250 1.145 0.500 0.291 11101)50 -200 318 291 /2.7 073 1012012 1114 1.375 1.490 0.500 0.432 1/1101? 32 34.9 31.8 127 .019 1012015 1½-2 1.375 1.490 0.500 0.421 1112015 40-50 349 3/8 12.7 .019 1012020 2-214 1.375 1.490 0.500 0.421 1772021) 1¼x , .50 65 34.9 37.8 121 .0/9 1012025 214-3 1.375 1.490 0.500 0.411 1112025 6.5 60 34.9 31.8 12.7 .0/9 1012030 3-4 1.375 1.490 0.500 0.389 77/2031) 80- lOt) 549 318 /2.1 0/8 1012050 5-8 1.375 1.490 0.500 0.389 71/2050 /'5 26) 348 3/ .1 /2.1 .0'd 1015015 114 1.625 1.610 0.875 0.477 1/15475 40 43 4,9 22.2 .(J22 1015020 2 1.625 1.610 0.875 0.477 111.020 1½x .5!) 41.3 6)0 27.2 1)22 1015025 214 1.625 1.610 0.875 0.477 11 16)155 - C,5 4'.,; -11) 4 22.2 .02. 1015030 3-4 1.625 1.610 0.875 0.477 /706)20 1i It..; 6)3 499 1015040 4 1.625 1.0.875 0.477 1(75043 iOu 4 4 _____ 1015050 5-8 1.625 1.6H100.875 0.477 ______ 4 &MEFRIT Weld-Miser 1M Tee-Let® Welding Outlet Fittings 1qL IL1Ifl Il DIMENSIONS & PARTINUMBERS T Nominal Nominal Outlet Inside Make g hI Outlet Header Length Diameter Up Each F A B M as D In (nn) In frim) In frmnt) In (mm) In (mm) Lb. (*q) 2 1.750 . 2.067 0.875 0.857 1120020 Si) 445 52.5 22.2 038 1020025 214 1.750 2.067 0.875 0.829 /12002:1 o5 -/4.5 52.5 222 038 1020030 3 1.750 2.067 0.875 0.829 1120030 2x By 445 Vs 222 ().19 1020040 4 1.750 2.067 0.875 0.800 /720040 lOu 44,; 52.5 222 096 1020050 5 1.750 2.067 0.875 0.743 1121)050 725 44.5 525 22? 03-1 1020060 6 1.750 2.067 0,875 0.743 1120060 150 415 s2.5 222 0.!4 1020080 8 1.750 2.067 0.875 0.743 1120090 1100 J4.5 525 222 0.24 1025025 21h 2.215 2.469 1.125 1.250 1125025 65 4fl 52.7 28.6 055 1025030 3 2.215 2.469 1.125 1.200 1125031) 90 40 62.1 28.5 0.5 1025040 4 2.215 2.469 1.125 1.150 /125010 2½x 10 10 627 28.6 052 1025050 5 2.215 2.469 1.125 1.150 1125050 123 510 62 7 28,6 0.52 1025060 6 2.215 2.469 1.125 1.150 1125060 /50 540 62.1 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 201) 540 62.7 28.6 0.52 1030030 3 2.500 3.068 1.500 1.550 80 63.5 /1.9 381 0.11) 1030040 4 2.500 3.068 1.500 1.450 3x 100 - 63.5 11.9 381 066 1030050 5 2.500 3.068 1.500 1.450 125 63.5 179 381 0.66 1030060 6 2.500 3.068 1.500 1.450 /53 63.5 i7.9 38.1 0.66 1030080 8 2.500 3.068 1.500 1.450 63.5 1.'9 38.1 0.56 1040040 4 3.000 4.026 2.000 2.850 /69? 11 4.j 506 1.29 1040050 t6)) 3.000 4.026 2.000 2.850 4 x ' 75. 15.2 /02.3 .1.8 129 1040060 6 3.000 4.026 2.000 2.800 .0.1 . yj8 1.2.' 1040080 8 3.000 4.026 2.000 2.800 '62 .' sOS 12, Note: Part #1002002 Is not UL Listed or FM Approved. Part #1012012 Is not FM Approved, All size-on-size (i.e 2 X 2) Tee-Lets are not FM Approved iNJhStar Ment- 110 -6- Rm PducnOMijan tMv ,t,na1joiui 4MEFRIT Weld-Miser1M Tee-Let® Welding Outlet Fittings Typ B 199 Thread Standard Weight Type C Cut Groove Standard Weight flh!'dL111J !I DIMENSI ONS liimumu SIZES1hI:RuV Male Thread Cut Groove Nominal Outlet Nominal Header Outlet Length Inside Diameter Outside Diameter Wall Thickness NPT(8SPT) NPT(BSPT) In.(inm) In. (mm) ln.(rrrrn) ln.(nar) In.ftnra) In. (n;m) 1310012 2010012 11/4-114 3 1.049 1.315 0.133 32 40 80 33 4 34 1310015 2010015 1½-2 3 1.049 1.315 0.133 lx 00 bO 81) "L C, .3.i.( 34 1310020 2010020 2-214 3 1.049 1.315 0.133 5) 6 10 '6 b 334 3.4 1310025 2010025 214-4 3 1.049 1.315 0.133 bb - 0)1) 80 .134 .34 1310050 2010050 5-8 3 1.049 1.315 0.133 125 200 80 368 :134 34 1312012 2012012 11/4 3 1.368 1.660 0.140 3;' 131) .34 422 36 1312015 2012015 114 3 1.368 1.660 0.140 1'/4x II) 84, .44 42e 36 1312020 2012020 2-2½ 3 1.368 1.660 0.140 65 81) 34 42.2 31' 1312025 2012025 3-4 3 1.368 1.660 0.140 no 11)0 81) .14 / 42,1 .16 1312050 2012050 5-8 3 1.368 1.660 0.140 (25 iLJO 80 3.11 422 36 1315015 2015015 114 3 1.610 1.900 0.145 41) 80 .109 48.3 lz 1315020 2015020 2 3 1.610 1.900 0.145 1½x 50 80 409 483 3.1 1315025 2015025 214 3 1.610 1.900 0.145 65 at) 40.9 38.3 3.1 1315030 2015030 3-4 3 1.610 1.900 0.145 80- 100 80 40.9 48.3 3.1 1315050 2015050 5-8 3 1.610 1.900 0.145 125 -200 811 409 483 3.1 1320020 2020020 2 3 2.067 2.375 0.154 80 525 60.3 39 1320025 2020025 214 3 2.067 2.375 0.154 65 80 535 603 39 1320030 2020030 3 3 2.067 2.375 0.154 2 x 80 80 52 603 3.9 1320035 2020035 4 3 2.067 2.375 0.154 1011 do 625 1)03 .3.3 1320050 2020050 5 3 2.067 2.375 0.154 125 80 525 601 33 1320060 2020060 6 3 2.067 2.375 0.154 1511 SI) 52.5 1)3.. 3.9 1320080 2020080 8 3 2.067 2.375 0.154 233 Z 5 tO..) .1 Note: Tee-Lets are manufactured to fit size-nn-sii that is tha cnntniire.il 5h2na nn 2 nh,pn Top_I at it m2r1a tn fit narfortk, nn tha firt Iietw1 h02d0r d,a If Inot2IIogI on the second header size marked on the fitting, a slight gap of approximately 142 will appear along the longitudinal centerline of the header. For example, a 1 x 2 - 214' Tee-Let, is a 1 outlet fitting manufactured to fit perfectly on the 2 header size listed, while leaving a 1/2 gap along the longitudinal centerline of the 21h' size. It a perfect fit is required for a 214' header pipe, then a 1' x 214 - 3 Tee-Let would be ordered. Size consolidations are employed to reduce Inventory and provide for greater flexibility. -6- Merit- 1.10 A1I?1.Sta R,. Ppoduts DMilon of Anvil IntasdoaaI Type B Male Thread Standard Weight Ty C Cut pe Groove Standard Weight 4bAIT® TypeC/R WeIdMiserTM Tee-Let® Roll Groove Schedule 10 Welding Outlet Fittings WELD-MI1I11 l ILET _' - DIMENSIONS( [i1allaYjiiIPA*fW4E!111 j Cut Nominal Nominal Mae T ad Outlet Inside Diameter D Outside Wall Thickness - F Standard Schedule Standard Schedule Std. Groove Std. Rol l Groove 10 Outlet Header Length Diameter Wt. A B C Weight 10 E Weight 10 NPT(SO 7./) NPT(ISO'l 1) NPT(IS0•7 1) In4mn) In.(inm) In. 0179 In. (mrn) In.(irnn) In. (mm) !n(nm) In.(imri) 1325025 2025025 2225025 2½ 3 2.469 2.635 2.875 0.203 0.120 , 125025 81) & 1 6? 0 6.2 50 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 212j' 0,70 Si) 80 627 610 76.2 50 .3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 1125035 2½x 120 80 621 5/0 762 50 JO 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 2/25051) /2. 80 62.1 61.0 76.2 50 30 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 151) 80 027 61.0 '6.2 I 50 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 201) 50 621 o7.2 76.2 50 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 8) 80 180 83.0 68.0 50 3,0 1330035 2030035 2230035 314 3 3.068 3.260 3.500 0.216 0.120 85 80 780 830 88.0 5.0 .30 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3 x 8' 100 81) 118.0 830 88.0 j.0 .30 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 1 Si: . 8.6 830 88.0 5.0 30 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 151) 80 ;S'J 830 880 50 3.) 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 80 '30 83.0 880 50 30 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 /00.0 114.0 6.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4* "' 12 IOU 1020 108.0 1/4.0 6.0 30 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 101) 1620 1380 114.0 60 3.0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 _____ __________ 200 101) !07'C 138) 1140 6.0 30 - 2050050 - 5 4 5.047 - - 5* 72.5 IOU - 2050060 - 6 4 5.047 - - ______ ____________ ______ 15.3 'iii; 726 2 - 2050080 - 8 4 5.047 - - _____ ___________ 7/Jo ..J 1252 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6* ,jj li. ;5C' S 758 i IL- 7) jo - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 30 - 2080080 - 8x 8 4 7.981 8.329 8.625 I 0.322 i 0.148 , I" . C.0 JO Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shaDe on a olven Tee-Let is made to fit nerfectiv on the first listed header 517P. It instlted on the second header size marked on the fitting, a slight gap of approximately Y&' Will appear along the longitudinal centerline of the header. For example, a 1' It 2 - 2,'t Tee-Let, Is a 1 outlet fitting manufactured to fit perfectly on the 2' header size listed, white leaving a ½z" gap along the longitudinal centerline of the 214' size. If a perfect fit Is required for a 214' header pipe, then a 1' x 214 - X Tee-Let would be ordered. Size consoidations are employed to reduce Inventory and provide for greater flexibility. Meni -170 - -7- R,ePd,,cn DMdon orvI lntemiorai July 2012 For the most current product/pricin information on An'il products, plea t our website at www.anvilintl.co n ()I N T E R N AT I a N A L Building Connections That Last q SP *F/RNVIL Steel Pipe Nipples 8 Malleable Fittings BUILDING CONNECTIONS THAT LAST Encatawissa (Jiwus r4IvvI. wlL-uiJ 3jNOE (( *11 NLS'1FJ[SffiWV%Pmt1=PE ffita Standard Welded Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured product requirements. Dimensional: ASIM A733 Standard End Finish Tapered Pipe Thread (N PT) - Material: ASTM A53 Type F or Type E Galvanizing Hot Dip Galvanizing* Threading:** ASME B 1.20.1 *Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. **British Standard threading per BS 21 available upon request. Ends are cut square to the central axis. All burrs on Also available: the inside are removed. The ends of the pipe nipples • Ready Cut Pipe, Standard - Schd. 40 (black and galvanized) are chamfered on the outside at an angle of 35° +1- Pipe Size: /2, 3/4", 1', 11/4 , 11/2 , 2" 10 to the central axis. Pipe Length: 8", 24", 30", 48", 60", 72" "66" Packs, Standard - Schd. 40 (black and galvanized) Pipe nipples are threaded on both ends with Nipple Size: 1/3", 01/4, 1", 1)14', 11/,", 2" standard NPT tapered threads. Threads are right • Single Run Nipple Packs (black and galvanized) hand on both ends. Pipe Size: 1/2", 3/4", 1, 11/4, 1)12", 2" 1/8 .405 3/4 172 2 2 '/2 3 31/3 4 41/2 1 5 51/2 6 7 8 9 10 1 11 12 1/4 .540 7/8 1 1/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 3 /8 .675 1 1 1/2 2 2 1/2 3 31/3 4 4'/2 5 5 6 7 8 9 10 11 12 1/2 .840 1 1/8 1 1/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 3/4 1.050 1 /8 172 2 2 1/2 3 3 '/2 4 41/2 5 5 1/2 6 7 8 9 10 11 12 1 1.315 1 1/2 2 2'/2 3 31/2 4 41/2 5 5'/2 6 7 8 9 10 11 12 1 1/4 1.660 1 5/8 2 2 72 3 31/2 4 4 5 51/2 6 7 8 9 10 11 12 172 1.900 1 3/4 2 2'/2 3 31/2 4 41/2 5 572 6 7 8 9 10 11 12 2 2.375 2 2/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 2 1/2 2.875 2 1/2 3 31/2 4 41/2 5 572 6 7 8 9 10 11 12 3 3.500 2 5/s 3 3 1/2 4 41/2 5 51/3 6 7 8 9 10 11 12 4 4.500 2/8 4 41/a 5 51/2 6 7 8 9 10 11 12 6 6.625 1 3 1/8 4 4 1 /2 5 51/2 6 7 8 9 10 11 12 [)iJi&ww.wanviui1mrcom LID HERIBI 0 EUR:- ZG Class 10 (Standard) ELBOW IA MAP '1 0.69 0.06 '/4 0.81 0.10 0.95 0.15 1/2 1.12 0.22 3/4 1.31 0.36 1 1.50 0.57 1 1/4 1.75 0.87 1 ½ 1.94 1.16 2 2.25 1.81 2½ 2.70 3.23 3 3.08 4.82 4 3.79 8.41 6 5.13 19.96 450 ELBOW / 1/8 0.63 0.06 0.73 0.11 E 0.80 0.14 0.88 0.20 3/4 0.98 0.32 1 1.12 0.50 1 1/4 1.29 0.76 1 1/2 1.43 1.00 2 1.68 1.61 2 /2 1.95 2.77 3 2.17 4.03 4 2.61 6.92 6 3.46 16.31 Class 150 (Standard) CAP CAP - Size A Weight (t1 1 I A '/8A 0.53 0.03 1/4 A 0.63 0.05 3/8 A 0.74 0.07 1/2 0.87 0.11 '/4 0.97 0.18 1 1.16 0.30 1 1/4 1.28 0.44 1 1/2 1.33 0.55 2 1.45 0.85 2 1/2 1.70 1.49 3 1.80 2.20 3 1/2 1.90 3.02 4 2.08 3.79 6 2.55 8.77 A Supplied in Steel only (Black and cialvanized). TEE Size A Weight F- LLJ___ ____ A- ½ 0.09 0.95 0.21 ½ 1.12 0.31 J 14 1.31 0.50 1 1.50 0.79 1 1/4 1.75 1.19 1 ½ 1.94 1.57 2½ 4.33 4 3.79 11.03 6 5.13 25.98 vAinviiiiiii Class 10 (Standard) REDUCING COUPLINGS . 1fr4e A W eight I I Y4xh/8 1.00 0.07 3/8 x 1/8 1.13 0.09 3/8 X Y4 1.13 0.10 Y2x h/8 1.25 0.13 V2xh/4 1.25 0.13 ½x 3/8 1.25 0.14 3/4 x 1/8 1.44 0.18 3/4 x 1/4 1.44 0.20 3/4 x 3/8 1.44 0.21 3/4 x½ 1.44 0.22 1 x½ 1.69 0.34 1 x% 1.69 0.36 1 1/4 X 1/2 2.06 0.47 1 ½x 3/4 2.06 0.51 1 1/4 x1 2.06 0.57 1 V2X h/2 2.31 0.62 1 1/2 x 3/4 2.31 0.66 _______ 1 1/2 x1 2.31 0.73 1 ½x1 1/4 2.31 0.80 2 x ½ 2.81 0.94 2.81 0.99 2 x 1 2.81 1.03 2x11/4 2.81 1.17 2x1½ 2.8 1.25 2½x1V4 3.25 1.81 2½x11/2 3.25 1.90 2 ½x2 3.25 2.04 3 x 1 3.69 2.48 3x 1 ½ 3.69 2.55 3 x 1 ½ 3.69 2.67 3 x 2 3.69 2.78 3 x 2 1/2 3.69 3.23 4 x 2 4.38 4.43 4x2½ 4.38 4.87 4 x 3 4.38 5.29 - .---- IW/ _ _ 'y .:. .. • __________ _____________ 1S H, Lightweight Flexible Coupling IJ%IVI L5 qCSPF/RNV1>L The C-3 Coupling is a flexible light weight style which is ideal for fire protection services and other services where low pressure and ambient temperature conditions are expected. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c®us <3> LPM LISTED APPROVED 0 For Listings/Approval Details and Limitations, visit our website at wv.anvlllntLcom or contact an Anvil' Sales Representative. MATERIAL SPECIFICATIOWS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-i 83 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: CRust inhibiting paint Color: ORANGE (standard) C1 Hot Dipped Zinc Galvanized (optional) DOther available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: I:IStandard Gruviok 0 Gruvlok XtremeTM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. Pre-Lubricated Grade "E" EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry loll free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. 0 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Ronge)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: Standard C Style C] Flush Gap PROJECT INFORMATION Project: APPROVAL STAMP []Approved Address:[]Approved as noted Contractor: LI Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 pciLIGHTWEIGHTIFLEXIBLE .1.1uJ :11 R [c Nominal Pipe ' Max. End Range of Deflection From Q. 'Coupling Dimensions Coupling Bolts Specified Torque § Approx. Size 0.D. Pressur:, WorkPipe End Load Seiaration Wt. Ea. Per Coupling Pipe X V Z Oty. Size Min. Max. InJDN(mm) InJmrn PSI/bar Lbs./kN InJmm Degrees InjFt. - mm/rn In/mm In/mm In/mm In/mm Ft-Lbs JN-m Lbs/Kg 1 1.315 300 407 0-V32 1°22' 0.29 21/2 4 1/4 2 3/8 x21/l 30 45 1.2 25 334 20.1 /81 00.79 ___ 23.8 64 102 44 - MI0xS7 40 60 0.5 ]l/4 1.660 300 649 0-½ 10 5. 0.23 23/4 41/4 13/4 2 3/ x 21/4 30 45 1.3 32 42.2 20.1 2.89 0-0.79 /8.8 70 III 44 - COX 50 40 60 0.6 1½ 1.900 300 851 0-½2 00 57' 0.20 3 41/2 13/4 2 3/8 x2'/4 30 45 1.5 40 48.3 20.1 3.18 00.19 16.5 76 Ill 44 - /dI0xS0 40 60 0.7 2 2.375 300 1,329 0-½2 00 45' 0.16 3% 5 1% 2 /8 x 21/4 30 45 1.7 50 603 20.1 .5 91 00.79 131 66 1 /40 48 - A1I0. 57 40 60 1 0.8 21/2 2.875 300 1,948 0-½2 00 37 0.13 3% 51/2 11/8 2 3/ x 21/4 30 45 2.0 65 13.0 20.1 8.66 00.79 10.9 99 146 48 1 - Al/Ox 57 1 40 60 0.9 30.0. 2.996 300 ZIIS 0-. 0 36 013 4. 5. l 2 30 45 1.9 76.1 76.1 20.7 9.41 0-0.79 10.4 10.5 146 48 - M10 x 57 40 60 0.9 3 3.500 300 2,886 0-½2 00 31 0.11 41/2 6'/8 1/t 2 1/2 x 21/2 30 45 2.6 80 88.9 20.7 /2.81 04).79 89 114 1 /56 48 - M10x63 40 60 1 12 4 4.500 300 4,771 0-%i 10 12 0.67 61/8 8 21/4 2 5/ x 31/2 80 100 4.1 /00 i!4.3 20.7 2/22 1 02.38 ________ 5 5.5 156 203 57 - /6 12't 70 110 150 1.9 51,50.0. 5.500 300 7,127 0-., 0,59,0.54 6'i 9'x 21 2 Ilix3½ /00 130 5.5 139.7 139.7 20.7 31.70 0-2.38 45.4 175 237 57 M16 x 89 135 175 2.5 5 5.563 300 7,292 0-/32 00 58, 0.54 7 9½6 21/4 2 ½ x 31/4 100 130 5.7 /25 /41.3 20/ 32.11 0-6.4 45 178 237 57 - 6116x85 /35 /75 2.6 6:0.0 6500 300 9,955 02 050' 046 7: 10>5 2' 2 "x3 100 /30 6.1 165.1 1 165.1 20.7 1 44.28 0-2.38 34.8 200 267 57 1- M16 x 85 1 135 175 2.8 6 6.625 300 10,341 0-/32 00 49 0.45 8/4 103/4 21/4 2 ½ x 31/4 100 130 6.1 150 168.3 20.7 46.00 0-238 31.8 210 213 51 - ,ti116x85 135 175 2.8 8 8.625 300 17,528 0-/32 00 37' 0.35 101/a 131/2 21/2 2 3/4 x 41/4 130 180 11.9 200 2/9.1 207 7191 02.38 1 29.! 1 270 1 343 64 - M20x /10 115 245 . 5.4 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. One time field test pressure may be increased to 1.5 times the figures listed above. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are For reference only and based an Sch. 40 pipe. For the latest UL/UIC, FM, VdS and IPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. FP-4.12 I A WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok0 XfremeTM Lubricant is required. FIG. C-4 L.I..1uIij.l . ________ The C-4 Rigid Coupling is our standard coupling and is designed for rigid piping applications. The C-4 is specially designed to provide a rigid, locked-in pipe connection to meet the specific demands of rigid design steel pipe. For the latest UL/UC listed, LPCB, YdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. C @ us <a> (In) E~ LISTED APPROVED For Listings/Approval Details and Limitations, visit our websile at www.aveilinll.com or contact an AnviP Sates Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-i 83 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts mode of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) F1 Hot Dipped Zinc Galvanized (optional) 0 Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: 0 Standard Gruvlok []Gruvlok XtremeTM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. o Pre-Lubricated Grade "E" EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. 0 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-Free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. El Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: O Standard C Style O Flush Gap PROJECT INFORMATION APPROVAL STAMP Project: ID Approved Address:[]Approved as noted Contractor: IJ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 AS ri..ii tiurn wI'iII [cj 1D COUPLIPJG Nominal I Pipe Max. Max. Coupling Dimensions Range of Pipe Coupling Bolts Spedfied Torque § Approx. Size 0. D. Working PressureA End Load End Separation X Y Z Wt. Ea. - Oty. Size Mi Max. IñjDN(mm) In./mm PSI/bar Lbs./kN In 1mm In./mm In1mm In 1mm In /Mm Ft.-Lbs./N-n, Lbs .1Kg 1 1.315 300 407 0-V32 2/t 4 ]3/ 2 %42Y4 30 45 1.2 25 33.4 20.7 1.81 00.79 60 102 44 - 1,1,10x 57 40 60 0.5 lA 1.660 300 649 0-V32 2/4 45/4 11/8 2 3/ x 21/4 30 45 1.5 32 42.2 20.7 2.89 0-0.79 70 /17 48 - MIOx57 40 60 0.1 1112 1.900 300 851 O/32 213A6 41/8 P/a 2 % a 21/4 30 45 1.7 40 48.3 20.1 3.78 0-0.79 1 71 /24 48 4110x57 40 60 0.8 2 2.375 300 1,329 0-V32 31/2 5% 2 2 % a 21/4 30 45 1.9 50 1 60.3 207 591 00.79 89 /37 SI - /1/0.157 40 60 0.9 21/2 2.875 300 1,948 0/32 4 6 2 2 3/ a 21/2 30 45 1.9 65 73.0 20.1 8.66 00.19 /02 /52 51 - MIOI 63 40 60 1 0.9 30.0. 2996 300 2,/IS 0-;. 4 61; 1' 2 x2Y 30 45 2.2 76.1 76.1 20.7 9.41 1 0-0.79 105 156 1 48 - M10 a 63 40 60 1.0 3 3.500 300 2,886 0-V32 43/4 61/8 2 2 /tx21/2 30 45 2.4 80 88.9 20.7 12.84 00.19 121 168 51 - MI0s63 40 60 1.1 4 4.500 300 4,771 03/33 5% 7/ 21/8 2 % x 21/2 30 45 3.2 /00 1/4.3 20.1 21.22 0-2.38 149 /97 54 - ,'.110x63 40 60 1 1.4 5500 300 7/21 0:: 6, 9. 7- 2 3 80 /00 5 139.7 139.7 20.7 31.70 1 0-2.38 175 235 1 52 - M12 476 110 150 2.2 5 5.563 300 7,292 0-/32 6 5/6 9'/ 2Vi 2 /2 x3 80 100 4.5 125 /41.3 20.7 32.44 0-2.38 /76 230 52 - M12x76 1/0 /50 2.0 6'00 6.500 300 9,955 0'.%8 l0 2 2 80 100 5.8 165.1 165.1 20.7 44.28 0-2.38 207 264 54 - M12 476 110 150 1 2.6 6 6.625 300 10,341 0-/32 8¼ 103/ 2¼ 2 1/2 831/4 80 100 5.8 /50 168.3 20.1 4600 1 0-2.38 210 264 1 54 4112x82 /10 /50 2.6 8 8.625 300 17,528 0-3/32 101/2 131/4 1 21/2 2 s/8 a 3½ 100 130 10.8 200 1 2191 20.7 17.97 0-2.38 267 337 64 - 4116s09 130 /75 4.0 10 10.750 300 27,229 0-3/32 13 16/4 21/8 2 7/5 180 220 21.5 250 273! 20.7 /21.12 0-2.38 33/ 425 67 f/22x125 245 298 9.8 12 12.750 300 38,303 0-/32 15% 19V4 25/8 2 1/8 x5½ 180 220 27.4 300 323.9 20.7 1 170.38 1 0-2.38 1 391 489 61 1 -. 41224 140 1 245 1 298 1 /2.4 Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. One time field test pressure may be increased to 1.5 times the figures listed above. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and IPCB pressure ratings versus pipe schedule, please visit onvi?inH. cam or contact your local Anvil Representative. Other sizes available, contact an Anvil Representative. FP-4.12 WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® XtremelM Lubricant is required. c®us LISTED APPROVED OLPM For Listings/Approval Details and Umitalions, visit our wobsite at www.anvlllnll.com or contact an Anvil' Solos Representative. CAST FITTINGS: Ductile Iron conforming to ASTM A-536 FINISH: O Rust inhibiting paint Color: ORANGE (standard) or OHot Dipped Zinc Galvanized conforming to ASTM A-i 53 (optional) DOther available options: Example: RAL3000 or RAL9000 Series 900 Elbow 01E?~~3D, O.D. -i U to E LI' ELBOW Nominal o D Center Approx. Size PS to End Wt. Ea. !n./DN(mm) In./mm PSVbur In 1mm LbsjXg 1 1.315 300 21/4 0.6 25 33.4 20.7 57 0.3 1¼ 1.660 300 21/4 0.8 32 42.2 20.7 70 0.4 1½ 1.900 300 21/4 1.1 40 48.3 20.7 70 0.5 2 2.375 300 31/4 1.5 50 60.3 20.7 83 01 21/2 2.875 300 31/4 2.5 65 73.0 207 95 LI 300. 2.996 300 3' 29 76.1 76.1 20.7 95 1.3 3 3.500 300 41/4 4.2 80 88.9 20.7 /08 1.9 4 4.500 300 5 6.7 /00 1/4.3 20.7 IN 3.0 5½ 0.0. 5.500 300 5½ - 139.7 139.7 20.7 140 - 5 5.563 300 5/2 11.9 /75 /41.3 20.7 /40 5.4 6--.09. 6.500 300 6'1' /8.2 165.1 165.1 20.7 1 165 8.3 6 6.625 300 6/2 17.3 /50 168.3 20.1 165 7.9 8 8.625 300 71/4 32.2 200 219.1 20.7 197 14.6 10 10.750 300 9 54.1 250 273.1 20.1 229 24.5 12 12.750 300 10 70.0 300 323.9 207 254 31.8 PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: []Approved as noted Contractor: El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 The Model RC-2 Reducing Coupling makes it possible to directly connect two different pipe sizes, eliminating the need for two couplings and a reducing fitting. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. Working pressure ratings shown are for reference only and are based on schedule 40 pipe. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. Reducing Coupling Housing Gasket Gasket Center Rib C®Us <e>OLPM LISTED APPROVED For Listings/Approval Details and Limitations, visit our websito at www.anvilinll.corn or contact an Anvil° Satan Representative. Model RC-2 Coupling complete with Grade "E" EPDM Gasket. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck hack head bolts conforming to the physical properties of SAE J429 Grade 5 with a minimum tensile strength of 120,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A, or J995 Grade 2 Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) [I Hot Dipped Zinc Galvanized (optional) 0 Other available options: Example: R.A13000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: OStandard Gruvlok 0 Gruvlok XtremeTM required for freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. 0 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. PROJECT INFORMATION APPROVAL STAMP Project: DApproved Address:[]Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 RC-2 REDUCING COU J U [e Nominal I Larger I Smaller Max. ' Max. End Range of Deflection From Q. Coupling Dimensions Coupling Bolts 'Specified Torque § Approx. Size 0.D. 0.0. Working PressureA Load Pipe End Separation Wt. Ea. Coupling Pipe - X - Y Z - Qty. Size Min.Max. In./DN(mm) In/mm In/mm PSI/bar Lbs./kN In/mm Degrees InIF!. -minim In/mm In 1mm In./mm In/mm Ft-Lbs IN-rn Lbs .1Kg 2x 11/2 2.375 1.900 300 1,329 0-V32 00 45' 0.16 3% 5% 1% 2 1/2 x 2/4 80 110 2.0 50.440 60.3 48.3 20.7 5.19 00.79 /3.1 92 /49 48 /612.476 I/O 150 0.9 21/2 x 2 2.875 2.375 300 1,948 O/32 00 37 0.13 41/4 6% 1'/t 2 1/2 x 2/4 80 110 3.5 65x50 73.0 60.3 20.7 8.67 00.79 _______ /0.9 108 162 48 /612.476 110 150 /6 300.42 2.996 2375 300 2.115 0-' 036 0.12 C 6 I 2 x2 80 110 3.3 76x60 16.1 60.3 20.7 9.41 0-3.2 9.9 108 162 48 - M12 x76 110 150 1.5 3x 2 3.500 2.375 300 2,886 0/32 00 31 0.11 4'/o 71/8 1% 2 1/2 x 2/t 80 110 4.4 80x50 88.9 60.3 20.7 12.84 0.079 89 /24 181 49 !?2.476 110 150 1 2.0 3 x 21/2 3.500 2.875 300 2,886 0-½2 00 31 0.11 4% 71/8 1% 2 /2 x 21/4 80 110 4.1 80.o5 88.9 73.0 20.1 12.84 00.19 8.9 /24 181 48 - M12xlo /10 150 1.9 3309 3.500 2996 300 2.886 0-1 031 0.11 ( 1 I - 2 x2. 80 I/O 4.0 88 X 16 88.9 76.1 20.1 12.84 0-3.2 8.9 124 181 48 - M12 x 76 110 150 1.8 4 x 2 4.500 2.375 300 4,771 0-/32 10 12' 0.25 61/4 8% 2 2 5/8 x 31/2 100 130 8.9 /0O.50 1143 603 20.1 21.22 02.38 20.8 159 275 SI 41,6,.95 135 175 1 4.0 4 x 21/2 4.500 2.875 300 4,771 0-/32 10 12' 0.25 61/4 8% 2 2 5/8 03½ 100 130 7.9 '00.465 043 /30 26? 21.22 0-2.38 20.5 159 225 51 - M16x95 1 135 /15 3.6 4 x 3 4.500 3.500 300 4,771 0-/3? 1°12' 0.25 61/4 8% 2 2 %x3½ 100 130 6.7 100x80 114.3 88.9 20.1 21.22 02.38 20.8 159 225 51 - /6/u k 95 /35 115 30 4 x 3 0 0 4.500 2 996 300 4,771 0-' 112' 075 6. 8< 2 2 5x3' 100 130 1.6 114 X 76 114.3 76.1 20.7 21.22 114.8 20.8 159 225 51 - M16 x95 135 175 3.5 5, 0.0 '4 5.500 4500 300 7,128 0. 158' 0.20 7:. IC 2' 2 u4' /00 130 /1.4 139 X 114 1 139.1 114.3 20.7 1 31.71 0-4.8 10.8 184 1 270 54 1 - M20 115 135 175 1 5.2 5 x 3 5.563 3.500 300 7,292 0-1/4 1 0 58 0.20 71/4 10% 21/8 2 3/4 041/3 130 180 10.4 125x80 141.3 1 88.9 207 32.44 06.4 /6.8 /84 270 54 1 M20 115 /75 25 4.1 5 x 4 5.563 4.500 300 7,292 0-/32 10 58' 0.20 7114 101/8 21/8 2 3/4 04½ 130 180 11.4 I25s106 141.3 114.3 20.1 32.44 0-2.38 /6.8 184 210 54 - M7O.iI5 /15 245 5.2 u.0.0..4.S 6,500 3500 300 9955 0- 120' 0.26 8 II' 2. 2 .44 130 ISO ISO 165 X 88 165.1 88.9 20.7 44.28 0-6.4 18.2 210 295 54 - M20 x 115 175 245 1 6.8 6 00.44 6500 4500 300 9955 0 120' 0.26 8 II 2.' 2 ,4. 139 180 13.6 165 Xli 4 165 114.3 20.7 44.28 0-6.4 18.2 210 1 295 54 - M20 x 115 175 245 6.2 6x 4 6.625 4.500 300 10,341 03/ 00 49' 0.17 81/4 111/8 21/8 2 3/4 04½ 130 180 13.4 50 /00 /083 1/43 207 1 4600 0238 14/ 2/0 295 54 /62O. I'S /15 245 61 6 x 5 6.625 5.562 300 10,341 0-'/32 0°49' 0.17 81/2 11% 21/a 2 /ix4½ 130 180 13.5 150,, 05 /683 1413 207 46.00 02.35 141 7/6 295 54 M21'z115 115 245 6.1 8 x 6 8.625 6.625 300 17,528 0-3/32 00 31 0.13 101/2 14 21/4 2 3/4 04½ 130 180 17.7- ?0,7 X 150 2/91 "<83 20.7 77Y1 0238 /0.9 267 1 365 1 57 - l,120x115 115 245 1 80 ?s6' 0.0 8.625 6504' 300 11.528 0 03?' 0.13 10.. 14 2 2 x4' 130 /80 /8.7 219 X 165 219.1 165.1 20.7 77.97 0-6.4 10.9 267 365 57 - M20x 115 1 175 1 245 8.3 Not for use in copper systems. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled For cut groove pipe. See technical data section for coupling data chart notes. - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Other sizes available, contact an Anvil Representative. FP-9.12 c®uS <> OLPM LISTED APPROVED For Listings/Approval Details and Limitations, visit our websito at www.anvilintl.com or contact as Ass/I0 Sales Representative. MATERIAL SPECIFICATIONS CAST FITTINGS: Ductile Iron conforming to ASTM-A536 COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) or OHot Dipped Zinc Galvanized conforming toASTM A-153 (optional) []Other available options: Example: RAL3000 or RAL9000 Series FIG. SK-1 01E?~N3D, E to E tGROOVED 1 Nominal i 0 D End Approx. Size to End Wt. Ea. InjDN(mm) InJmm In 1mm Lbs 1Kg 1.315 11/4 0.3 25 33.4 25 0.1 1% 1.660 1 0.4 32 42.2 25 0.2 1 1/2 1.900 1 0.5 40 48.3 25 0.2 2 2.375 1 0.7 50 60.3 25 0.3 21/2 2.875 1 1.0 65 73.0 25 0.4 30.0 3.000 1 09 76.1 1 16.1 25 0.4 3 3.500 1 1.5 80 88.9 25 OJ 4 4.500 1,/16 2.7 100 114.3 27 1.2 5 5.563 1V66 4.4 I/S 1 1413 27 2.0 6/'O.D 6500 1 5.5 165.1 165.1 25 2.5 6 6.625 1Yl6 6.6 ISO 1683 2/ 3l) 8 8.625 1/is 11.3 200 219,1 30 51 10* 10.750 1/4 21.0 250 2/31 32 9.5 12* 12.750 1¼ 35.5 300 3239 32 16,1 'Supplied as Style K-i only. PROJECT11 Project: E] Approved Address: ]Approved as noted Contractor: []Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 ® Listed Max. Horizontal Load System NPS Sch. 30 .44 45a59n 60.89 goa 11/2" Q1383 1956 2394 2765 2" -4" 1383 1956 2394 2765 5" - A" 1 1383 1956 2394 27 1 All 10-40 I 1956 24 27 10" 10-40 1383 1956 2394 2765 1 12" 10-40 1870 2645 3238 374 System NPS Sch. 3Q..44 5g 1-1 1/2" 10,40 .c,r Certified Max. ASD H M27dOs 1680 3250 3" 10,40 1800 3490 4" 10,40 1370 2640 5",6", 8" 10,40 730 1420 * SPECIALLY LISTED PIPE A ST Pipes PVT LTD Al Jnzeera Steel Products Co. SAOG Allied Tube & Conduit Corp. Bihar Tubes LTD. Bluesteel Services L L C Borusan Mannesmann Sons AS Bull Moose Tube Co. Conares Metal Supply LTD. Hal Chin Worldwide LTD Hickman Pipe & Tube Corp. Jiedong Economy Development Testing Zone Jindal Industries LTD Jotindns Steel & Tubes LTD Mitsui Canada Inc. MS Pipe Cu. LTD Northwest Pipe Co. Pacific Pipe Public Co. LTD Saba Thai Steel Pipe Public Co. LTD Shield Pine Safety & Security LTD Satyr Roultini LTD Swustik Pipes LTD Tes.Tube Co. Universal Tube & Plastic Industries LTD Wrifung East Pipe Industry Technical Co. LTD Welded Tube . Berkeley LLC Wheatland Tube Co. Wh Div. Yieh Phui Enterprise Co. LTD Youngstown Tube Co. Zenith Birla (India) LTD S • a P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K 5 thru 12 Inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 1 1/4" required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 LSTED FM Approved -1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products are exclusively designed lobe compatible ONLY with other .AFCON products including parts and fasteners. resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER. AFCON will NOT warrant against she failure of its products when used in combination with usher products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit. when non-A FCON products have been, or are used. 3/13 FQ ZC~_A P, i, I P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32' WI 17 SIZE - BRACE PIPE: 1" and 1 1/4" Sch. 40 MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain or E.G. LISTING/APPROVAL - C®US USTED 203AEX2625 -G> FM Approved - 1950 OSHPD See Website. FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 FM 2-8. Load rating - see chart. ASSEMBLY Combine with proper AFCON components- see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Swivel allows attachment at any angle. * Visual inspection, verifies proper installation. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe and finish. Max. Horizontal Load Size 1-2 ® Ductile Base 2015 1500 Steel Base 2015 --- Specific AFCON products are exclusively designed to be compatible ONLY with other .4FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER. AFCON will NOT warrant against the failure of its products when used in combination with other pmducls, parts or systems not nsanufacturcd or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit. when non-AFCON products have been, or are used. 3/13 Part # 077......... 78 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING SIZE - SYSTEM PIPE: Nominal Pipe Size 1" - 12" Steel - Sch. 40 1 1/4" - 12" Steel - Sch. 10 MATERIAL - Carbon Steel FINISH - Plain or E.G. PATENT - No. 7,140,579 LISTING/APPROVAL 203A-EX 2625 FM Approved - 1950 OSHPD See Website. ® Listed Max. Horizontal Load System NPS Sch. 30"44" 45"59" 60"-89" 90- 1 - 1 1/2 10-40 1383 1956 2394 2765 2-4" 7-40 1383 1956 2394 2765 5"- 6" 7-40 1383 1956 2394 2765 8" 10-40 1383 1956 2394 2765 10" 10-40 1383 1956 2394 2765 12" 10-40 1870 26451 3238 1 3740 FUNCTION - Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 Load rating - see chart. AI7l%iIRt V - System Sch. 30"-44" 90"NPS 45"-59" 1-1 1/2 10-40 7-40 ~G> Certified Max. ASD HorizontfiLoad 420 02-3" 0 4" 860 7-40 860 7-40 50 5" 950 7-40 80 6" 0 8" 2220 10-40 1340 10 flLJLJSJiYLIJS.J1 - Combine with proper AFCON components- see disclaimer below. Align brace member parallel to face of 411 bolt flanges. Tighten 411 bolts until flanges are flat to flat. FEATURES * Patented - design eliminates bending of ears during installation. * Patented - design prevents over tightening on system pipe. * Improved assembly - ears connected for superior strength. * Visual inspection - proper installation when 411 bolt flanges are together. ORDERING - Part #, size - system pipe and finish. Specific ,4FCON products are exclusively designed lobe compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assenibly. Be advised the following warranty restriction will apply. DISCLAIMER - .4FCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not linsitcd to loss of business or profit, when non-A FCON products have been, or are used. 5/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER SIZE -SYSTEM PIPE: See Chart. MATERIAL - Carbon Steel. FINISH - Plain or E.G. PATENT - No. 6,334,285 LISTING/APPROVAL - c®us 203A-EX 2625, 203-EX 2551 LISTED FM Approved - 1950 OSHPD OPA-0601 See Website FUNCTION - Sway brace adapter for an AFCON sway brace assembly. Designed to attach to the horizontal flanges of a steel structural memb Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 8" hanger attachment. INSTALLATION - Per NFPA 13 and these instructions. Load rating - see chart. Combine with proper AFCON components- see disclaimer below. The structural members design will dictate specific attachment criteria ASSEMBLY - See drawing. Insert 1/2" x 1 1/4" attachment bolt in 086 bracket. Install 1/2" studs ti brackets and engage on steel flange. Install nuts on studs finger tighi additionally tighten 1 1/2 turns or torque to 40ft. lbs. Attach AFCON sway brace assembly on 1/2" bolt. * Studs, fasteners and boilfurnished by customer. FEATURES * Fits 1/4' thru 1 1/4" flange thickness. * Studs capture head of bolt, providing hold back. * Alternative to center loading beam clamp. ORDERING - Part # and finish. Specific .4FCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners. resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction ss'itt apply. DISCLAIMER. .4FCO,V will NOT warrant against the failure of its products when used in combination with other products, parts or systetos not manufactured or sold by .4FCO,V. AFCO,Vshall NOT be liable under any eircnn,stances whatsoever for any direct or indirect, incidental or consequential dansages of any kind, including but not lttntted to toss of business or profit, when non..4FCONproeloets have been, or are used. il/li P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. SIZE - ROD: 1/2' SIZE - SYSTEM PIPE: 8" max. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - c®uS203EX 2551 FM Approved FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on steel flange - thickness less than 3/4". Set bolt up or down. ASSEMBLY/ATTACHMENT - See drawing. Torque - 3/8= 60 inch lbs. or 1/2= 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/4 turn. Caution - Do not over tighten set bolt. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set bolt up or down. * Flat throat back to prevent twisting on structure during installation. ORDERING - Part #, rod size and finish. 11/09 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension he SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL- Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c\n/us 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" L-dimension is measured from hanger rod center to the strap end. FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 LENGTH P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 31161111,11 EYE ROD NOT WELDED 1/08 A ROD SIZE A B MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650 F 3/8 7/16 2 1/2 210 1/2 9/16 2 1/2 395 5/8 13/16 21/2 630 3/4 1 1 1 3 945 7/8 11/8 3 1/2 1315 1 11/4 4 1735 1 1/4 11/2 5 2800 11/2 2 6 4070 1 3/4 21/4 7 5490 2 1 21/2 1 8 1 7240 21/4 23/4 9 1 9520 21/2 3 10 1 11725 NOTE: 'A" dimension should not be 1/16" larger than fastener. Please notify factory if larger "A" dimension is needed. SIZE - 3/8 thru 7/8 inch rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. FUNCTION - For attaching to and hanging from wood beams where bolting through beam is desired. ORDERING - Part #, rod size, length, width of bend and finish. *POSSIBLE ALTERNATE = PART #535 SEE CUT SHEET P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 Inch pipe LISTED FOR STEEL/CPVC 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8' or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 'OUSTED' 203-EX 2551 1"- 8" -Q> Approval guide - 111- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WI. 5 Wt+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469,75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 1 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 1 2650 8 1/2 1 711.00 3805.00 1 4050 551 '.. /ACsD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFcONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - .4FCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCOtV products have been, or are used. 1/08 1 4 I P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 650 ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 1 4960 4420 11/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru 1 1/2 inch rod in 10' - 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain and E.G., ORDERING - Part #, rod diameter and finish. 12/10 Special Note: The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When purlin manufacturers specify 200 lbs. max. Locations I b BorE 3@ A-C-E 0 0 2( B.E 3@ B-D-F 0 2© A.0 4@ A-C-D-F P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER Tm TAPPED BRACKET SIZE — ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and S.S. LISTING/APPROVAL — &312 t 13/8 .250 cn3203 — EX 2551 PATENT - No. 6,568,642 FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT — See drawing. Center mounting hole accepts 3/8" and 1/2" fasteners. *FASTENER LOCATION OPTIONS — See chart. Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. Horizontal - When vertical space is limited. FASTENERS PER NFPA 13 LTtO FOR STEEL PIPE — SEE TABLE. FEATURES * Universal fastener array for enhanced mounting. * Radius -Tapped orifice: Aligns rod for easy thread engagement and eliminates structural deficiencies associated with rod inserts. * No speed/pal nuts required. ORDERING - Part # and finish. MOUNTING FASTENERS LISTED Wood Steel - 1/4 or #14 Tek Steel - #10 SMS or #905 Fastener Qty. Steel Mm. Qty. Steel Min. Qty. Steel No Pre-Drill Pipe Thickness Pipe Thickness Pipe 1/4x1'/2 LB I 2 14 GA. I 3 18 GA. I 2V 24 24 2 3 #14 x I /2 SMS I 2 16 GA. I 2 V2 3 4 2 4 2 4 20 GA. 2 3 #16x2DS 2 2 18 GA. I 2',2 4 4 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp. 20 GA. 3 I 2 1/4 x 2 LB I 2 @ B ONLY 2 3 SMSSl,cIMeI&Sorry 2 4 3 4 DS Dnv Srcw #14x2SMS I 2 LI3LogBoll 22 GA. 3 2 '/2 Gyp- Gypsum Bord 24 5/Il SAMMYS® FOR WOOD Not less than 2' nominal width Not less than 3' nominal thickness (2-1/2') (depth or side of vertical member) No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. 'Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. WCñib'6sitI Truss Consuti tru ss manutacture tsr recommended nstatlabon Pont. Pre4n1tsng maybe repaired for GST 238O. oat avartabto onpage-11,11111111 Ward, a ddm demororravon . www.itwbuifdex.com) 1/4" 1/4' 3/8' 3/8' #14 Black : TT Nut Driver , <' 3/8' Part#8113910 - - - 3/8' 1/2' #14 SW Red Nut Driver Part # 8114910 8002957 GST 100 1/4x1' 25 125 8003957 GST 2010 1/4x2' 1760 (Fir) 25 125 8007957 GST 10 1/4s1" 300 25 125 8008957 GST 2O 114x2' 1760 (Fir) 850 1475 25 125 8068925 GST 20-SS 1/4x2 1760 (Fir) 850 25 125 8009925 GST 25-380 318x2-1/2 - 2113 (Fir) - 1500 25 125 8010957 GST 30 1/4x3 2060 (Fir) 1500 1475 25 125 8069925 GST36-SS 1/4x3' - - 2060 (Fir) 25 125 8013925 GST 2 1/4 x 2 1760 (Fir) 25 125 8015925 GST3 1/4x3 2275 (Fir) 25 125 - EDU.SA V SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling unril nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. APPROVALS 8007957 GST 10 3/8' Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2' 850 1-1/2" 4" 1475 1-1/2' 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2' 8009925 GST2S-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-112"-4" 1500 1-1/2' 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3""" 1050 1-1/2" 8073925 SWG 20-SS 3/8' Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" 8038957 DSTR 1 3/8' Vertical 4 1500 .035" 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037' 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEKSO 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWOR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060' 8056957 SWDR 516 3/8" Horizontal 4' 1500 .037" 4' 1475 .060" 8054957 SWOR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEI< 50 3/8" Vertical 2-1/2" 850 70 Angle off Vertical 4" 1500 2" 940 029" 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027' 8153922 XP 35 3/8" Vertical 4" 1500 .060' 8294922 SXP 20 3/8" Vertical orupto45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060' SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2' 850 Pre-Pour Structural @ 3000ps1 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranne II LWC :5 35 PCF llbs/1131 185 .027" 8150922 XP 20 3/8" Vertical 250 .035" 185 .027" 8153922 XP 35 3/8" Vertical 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" Vertical 170 .027" 8294922 SXP 20 3/8" 45" 80 .027" Vertical 250 .060' 8295922 SXP 35 3/0" 90" 80 .060" 8293957 SWXP 35 3/8' Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMI, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060' Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies wi NEC Standards Sheet Steel Gauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1181" 3/161" 1I41" Nominal Decimal Equivalent .030" .036" .048' .060" .075" .105" .125' .188" .250' 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2' UL compliance with NEC Standards. SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is4' UL and FM tests were performed in compliance with NFPA 13 Standards. "SWG 20 Maximum pipe size in composite wood iced allowed by UL is 2-1/2" -.-1- -. Fastening requirement: 5 times weight of water-fitted schedule 40 pipe plus 250 pounds. I=Mffi 7n,_EJ=1=yste.n Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY® line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1" (25 mm) through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8" (M10) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8" or 1/2" (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2" (M12) threaded rod. The system meets the requirements of NFPA® 13, making it ideal for new construction applications. The total system is cULus® Listed and FM® Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). Features Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8" and 1/2" (M10 and M12) rod Capable of restraint distances up to 40" (960 mm) from pipe to structure with 1/2" (M12) threaded rod Meets requirements of NFPA® 13 section 9.3.6 Branch Line Restraint Pipe Attachment www.erico.com 1 1b2llt'1I1 Branch Line Restraint Structure Attachment to Steel Branch Line Restraint Structure Attachment to Wood/Concrete Branch Line Restraint Structure Attachment to Threaded Hole www.erico.com ERICD _ 1. j4iad -..- • ON i, —ni-el MirraMPARipe =04%rao ~ment Features Accepts 3/8" or 1/2" (M 10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection RS T OD / _ Specifications Material: Steel Finish: Electro-galvanized ? c®us csBBRP0100EG 1' 1.32' 3/8, 1/2 6.67" 1.63' 0.88 CSBBRP0125EG 1 1I4 1.66' 3/8', 1/2' 7.56' 1.97' 0.88 CSBBRP0150EG 1 1/2" 1.90' 3/8, 1/2" 8.20' 2.21' 0.88' csBBRP0200EG 2" 2.38 3/8", 1/2" 9.45' 1 2.69" 0.88" www.erico.com 3 /1llL'LJ - I - o 7c. 1 ni, mog W, L , MS- t =ee I Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to steel members with self-drilling/tapping screw FT —I RS LI!1 Specifications Material: Steel Finish: Electro-galvanized Rod Size "Re Height !~effgth Width Screw Diameter ScrP Plg 4 FT Iø1;I;M.1I(i sIr U Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 4 J LV RS "Reff M114-51111, 'M' 11 Features Swivel connector accepts 3/8" or 1/2" (M 10 or M12) threaded rod Attaches to wood or concrete structures Specifications Material: Steel Finish: Electra-galvanized c®us N M_1~_ 9 W[CrIll _0 Jze t:k'Pii t.rr Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 5 1I2lli11 Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads RS Specifications Material: Steel Finish: Electro-ga Ivan ized ? c®us Number Rod je Hht th Wth Diameter Length IRS H Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. cULus is a registered certification mark of UL L-C. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available atwww.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER'S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright© 2012 ERICO International Corporation. All rights reserved. CADDY. CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. w.eriCo.Com 6 10911J P POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC @ (~~* <a> A These vibrating type belts are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4(101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10' (250mm) Voltages Available: 24VAC I2OVAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Belts -4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK- 1 weatherproof backbox Model BBX- I deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-341 to 661C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) I2VDC MIBA-6-12 1750070 .1 2A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6 (150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) I20VAC PBAI2O8 1808120* .05A 99 84 10(250) I20VAC PBAI2OIO 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. àWARNING 1 In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the belt and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC St. Louis, MO, Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y- I PAGE I 0F2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 112' conduit entrance 5 3/4" ((46) L I 5/5 (41) ®POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. I Fig. 3 A.C. BELLS WHIT6 UN) WHI ) - 10" 3 ,:: TE(OUT : _ CK (OUT) FROM CONTROL PANELOR I.) I PRECEDING BELL (ISO) BLACK (IN)______ CAUTION, 2 11/16" WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN ANDOUT LEADS AS SHOWN. (68) DWG# 776.1 NOTES, I. WHEN USING AC BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. MYGO 776.3 DWG# 776.2 4 (/4" ((08) Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. 85400776- REV Y-1 PAGE 2 OF 2 01/13 VSR up /11~ _ POPff ER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number DN50 VSR-2 1144402 2 112 DN65 VSR-2 1/2 1144425 DN80 VSR-3 1144403 31/2' - VSR-3 1/2 1144435 4' DNIOO VSR-4 1144404 - VSR-5 1144405 DN150 VSR-6 1144406 8' DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2' thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN 12259-5)! VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-IO GPM (15-38 LPM)-UL Maximum Surge: I8 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 3OVDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2 conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C)- UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 AWARNING 1 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-121 I/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV L PAGE I OF 4 3/09 VSR 0. POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be in on the top side of the pipe where they will be accessible. The device should not be installed within 6' (15 cm) ofa fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. I). The vane must not rub the inside of the pipe or bind in any way. àCAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. DO NOTLEA VE CO VER OFF FOR Retard Adjustment Fig. I AN EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms p ' TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE I POINTS IN DIRECTION OF WATERFLOW CAUTION Role must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Led -E7E~_ DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing waler aclivales device in one direction only) SWG. 11,16-it laJ (in QADAPTER ADAPTER -.4 i...- 20mm±2n,mMAX. DN5O ONLY USE (2)5180162 ADAPTERS AS SHOWN ABOVE ovG# I146.lF Compatible _Pipe/ _Installation _Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Boll Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-I387 (LPC) ON (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DNSO 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/-.062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 1 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 1 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ±125 50.8 ± 2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3,2 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 1 6.55 - - - - VSR-6 6 DNISO 6.625 168.3 0.134 1 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146-REV L PAGE 2 OF 4 3/09 U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR ON 50— ON 65 2-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR ON 80— ON 200 3-8 in Own IllS-H Fig. 7 Mounting Dimensions 3.50 in 2.00 (89.0 mm) (50.8 2.3 in (59.mm) 1 PIPE DIA. + 5.25 in 1+133.4 mm) U-BOLT NUT 1 40 U-BOLT WASHER ____________ PIPE SADDLE PIPE PLASTIC PADDLE Fig. 8 GREEN GROUND (PE) POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Fig. 4 Switch Terminal Connections Clamping Plate Terminal G 0160. 11146-16 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the Connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device 6-13 inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8 of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. BELL Fig. 5 Typical Electrical Connections POWER SOURCE (E! 5 Model VSR has two switches, one can be used to operate a central SUITABLE FOR BELL TELOW ZONE station, proprietary or remote signaling unit, while the other contact A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. is used to operate a local audible or visual annunciator. For supervised circuits, see "Switch Terminal Connections" ON FIRE PANEL drawing and warning note (Fig. 4). ()Rn Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MFG. 65401146. REV L PAGE 3 OF 4 3/09 VSR Q POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) g The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig.6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH 7ASSEMBLY TO BASE BREAKOUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY (2) LOCATING PINS DO NOT REMO (2) RETARD HOt SCREWS (2) LOCATING P11 BOSSES IN BASE DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. 45401146 - REV L PAGE 4 OF 4 3/09 USTED APPROVED ROME I NiT 9 SIR Me I 100 Quaker Lane, Malvern, PA 19355 • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com The AGF Manufacturing, Inc. Model 7500 Pressure Gauge is an FM Approved/UL Listed 4" gauge designed for use on "wet" sprinkler systems. The AGF Model 7500 has been designed to meet the requirements specified in NFPA 13, 2007 Edition Chapters 7.1.1.1 - 7.1.1.2, 7.2.1 -7.3.1.3,7.8.7,8.16.1.2.2, and 8.17.3 SPECIFICATIONS Range: 0-300 PSI (Inside) 0-2000 Kpa (Outside) DIMENSIONS (29.5) - (87.9) 0 3.46 _• (MM) IN 1.16 Accuracy: ±3-2-3% ASME B40.100 Grade B Burdon Tube: Phosphor Bronze 0388 03.70 (98:6) (94.0) Window: Polycarbonate one-piece 00 ring and crystal Dial: Galvalume .56 SO L39±.03 Pointer: Aluminum, painted black (14.2) Case: PGE Xenoy6 DX2735 .-1/4-18ANPT .44±04 Connection: Brass, 1/4" AN PT LM The AGF Manufacturing, Inc. Model 7600 1/4" 3-Way Globe Valve is a UL Listed valve designed to connect the pressure gauge to the sprinkler systems. The AGF Model 7600 has been designed to meet NFPA 13 System Attachments stating, "...each gauge shall be equipped with a shutoff valve and provision for drainage." MODEL 7500 PRESSURE GAUGE WITH MODEL 7600 GLOBE VALVE AND 1/4" STEEL PLUG AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 4 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. SS-7500 2/14 1* I- ci I CT M1011T TESTANDRAIN® M8000 COMMERCIAL RISERPACK TM M8000 RESIDENTIAL RISERPACK TI ERCIAL RISERPACK M8011 TESTANDRAIN® ak a 1 a THE MODEL 7500 PRESSURE GAUGE AND MODEL 7600 3-WAY GLOBE VALVE ARE ALSO USED ON THE FOLLOWING AGF PRODuCTs: TESTeeDRAIN is a registered trademark of AGF Manufacturing Inc. 4 toIeIW111,! N 9S A. N. noi a 11M Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve TEST Ii? ORIFICE V it SIZE I IN. MODEL 1011 Szes: ±iI!flL!J The AGF Model 1011A TESTANDRAIN provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model lOilA features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (3, to 2') with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: 3/8" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), %" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE U is important to note that the pressure rating of the relief valve indicates an opnratirg rarlge of pressure for both aoeiiing and closing of the valve. Stericlaic relief valves are required to OPEN in at range of pressure between GO% and 10590 of their rating. The VCiVCS are required to CLOSE at a pressure above 80% of rhal. rating The r6ipfjaiwa shou'a be .istafcd where t is easily accessib!e for mainI.eance, Cae should he taken That the relict valve CANNOT be isolated from th systern when the system is operational A diet valve shoulo NEVER have a shutoft valve or a plug downstream of its outlet. SS-M101 1A_VO01 06/13 TESTANDRAINO is a registered trademark of AGF Manufacturing Inc. Model 1011 A C USTED ® TESTAN DRAI N® Model 101IA 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVEO Factory Rated at 175 PSI with other setting available Dimensions Model 1011 A - Front View SIZE A B C D E F G H 3/4" 79A6 11/2 2A6" 3/8" 3/8" 113A6" 49/16 6¼" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79A&' 11/2" 23A6" 3/8" 3/8' 113A6" 4/l6" 6'" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11¼" 715/16" 111A6" 2A6" 41/4" 3/8" 115/16" 5A6" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 2 iv" 816" 113/16" 31¼" 51/16" 37/8" 25/8" 81¼" 1O/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815/m' 11A6" 31¼" 51A6" 3/8" 25/8" 81¼' 1O/8" (227 mm) )45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) The Model 1011 provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16...4.1" Provisions shall he made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)-- & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in 1'ab)e 8.16.2.4.2. Chapter 316,2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting fu)) flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall he accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterf)ow alarm. Chapter 8.17.4,3.1 (Dry Pipe System) a trip test connection not less than 1 in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.1 7.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1'. at least one of which shall he brass. Chapter 7.1.2 a wet pipe system shall be provided with a listed relief valve set to operate at 175 PS) or 10 PS) in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3 A listed relief valve of not less than ½ in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1 .2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Model 1011 - Plan View Orifice Sizes '/8", YS, ½', '7/12",%° ELO". 34' ESFR", and K25"" Materials Handle ................Steel Stem ...................Rod Brass Ball ...................... C.P. Brass Body...................Bronze Valve Seat...........Impregnated TefionC Indicator Plate .... Steel Relief Valve .........Bronze Bypass Fittings... Brass Bypass Tubing.... Nylobraid Approvals UL and ).JLC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM MAUL IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Ava,!able on 1'" to 2 oe m-,,ts only- "AvalobIe on 11211 and 2' size units only Job Name: Architect: Engineer: Contractor: Description Manufactured from .020" white coated aluminun - - are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation di- rectly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Specifications Material: .020" aluminum with removable plastic coating Sizes: x 2' x 6" x 7" 9" x 7" 12" x 10" 8.5 xli" See current catalog for a full listing of all available signs. Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four cor- ners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the ap- propriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base mate- rial. (The 9" x 7" Fire Alarm Bell sign must be drilled if it is to be attached directly to the bell gong.) ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc r 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com FIRE SPRINKLER RISER INSIDE AUTOMATIC SPRINKLER SHUT-OFF VALVE LOCATED__ FTs ___ OPPOSITE THIS SIGN Sprinkler Identification Signs FPPI's Sprinkler Identification Signs are manufactured of aluminum, painted white then printed with "fade resistant" red ink. Each sign is drilled for easy installation and is plastic coated to prevent scratching of finish during shipment and final installation. Designed in accordance with NFPA requirements. UPart I r._ sIi.ii Box Qty. 02-002-00 Blank Sign w/border 6" x 2" 1000 02-006-00 Air Control, 6" x 2" 1000 02-010-00 Air Line, 6" x 2" 1000 02-014-00 Alarm Line, 6" x 2" 1000 02-018-00 Alarm Test, 6" x 2" 1000 02-022-00 Anti-Freeze System 6" x 2" 1000 02-023-00 Anti-Freeze System 5" x 7" 1000 02-024-00 Auto Sprinkler Shut-Off 12" x 10" 1000 02-026-00 Auxiliary Drain, 6" x 2" 1000 02-034-00 Control Valve, 6" x 2" 1000 02-036-00 Control Valve, 4" x 6" 1000 02-037-00 Control Valve, 5" x 7" 1000 02-038-00 Control Valve, 9" x 7" 500 02-042-00 Drain, 6" x 2" 1000 02-046-00 Drain Valve, 6" x 2" 1000 02-050-00 Dry Standpipe 6" x 2" 1000 02-051-00 Fire Dept. Connection 6" x 2" 1000 02-053-00 Excess Pressure Pump, 6" x 2" 1000 02-054-00 Entire System, 6" x 2" 1000 02-055-00 Fire Alarm Bell, 9" x 7" 500 02-056-00 Fire Alarm Bell, 7" Round 500 02-057-00 911 Fire Alarm Bell, 7" Round 500 02-058-00 F.S. Valve Do Not Close, 6" x 2" 1000 02-060-00 Fire Sprinkler Riser Inside, 6" x 2" 1000 02-062-00 From City Main, 6" x 2" 1000 02-066-00 In This Building, Tx 2" 1000 02-070-00 In This Section, 6" x 2" 1000 02-074-00 Inspectors Test, 6" x 2" 1000 02-077-00 Hydraulic System, 5" x 7" 1000 02-081-00 Hydraulic System, 8-1/2" x 11" 1000 02-082-00 Main Control, 6" x 2" 1000 02-086-00 Main Drain, 6" x 2" 1000 02-091-00 Multi-use System, Warning, 5" x 7" 1000 02-092-00 Normally Closed, 6" x 2" 1000 02-096-00 Normally Open, 6" x 2" 1000 02-098-00 Open Sprinkler, 6" x 2" 1000 SPRINKLERS THROUGHOUT BUILDING ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FPP( 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: "0-300 sprinklers, not less than 6 300-1000, not less than 12 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed.* Once the correct Spare Sprinkler Head Cabinet has been select- ed, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel fi nish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Specifications Material: Painted plain steel Finish: Red enamel Styles: 3 Spare sprinklers, 112or314 6 Spare sprinklers, 1/2or3/4 6 Spare, ESFR, 1/2, 3/4 or 1" 12 Spare sprinklers 1/2 or 3/4 24 Spare sprinklers 36 Spare sprinklers ©2000-2007 Fire Protection Products, Inc (FPPI) •• Fire Protection Products, Inc FPPI' 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com ECS Ejector Automatic Air Vent (PAV-W) R1 91 Specifications Stock Number: PAV-W PAV-WS (Supervised) Service Pressure: Up to 175 PSIG System Connection: 1" NPT Male Temperature Range: 40°F to 120°F (4.5°C to 49°C) Dimensions: 14"(L) X 7"(D) X 7"(H) Weight: 8 Lbs Clear Height: 5" Patented redundant float design eliminates piping to a drain Support Hanger Not Required r. U.S. Pat. No. 8,636,023 General Description The ECS Ejector Automatic Air Vent (PAV-W/WS) is a device that provides automatic venting of trapped air in wet pipe fire sprinkler systems. As a fire sprinkler system is filled with water, trapped air migrates to the high point of the system near the vent installation location which allows for trapped air to be vented. Trapped air contains oxygen which is the primary cause of corrosion in fire sprinkler systems. Corrosion in wet pipe fire sprinkler systems is directly proportional to the amount of oxygen trapped within the system piping, so a reduction in trapped air will in turn reduce the internal corrosion activity of the fire sprinkler system. Venting the trapped air in a wet pipe sprinkler system can also decrease water delivery time and reduce false water flow alarms. The ECS Ejector Automatic Air Vent must be installed as shown on the engineering design documents, if a location is not provided install the vent at an accessible high point on the fire sprinkler system remote from the system riser where gas can be vented and at a location that the pressure gauge provided for visual monitoring can be viewed from directly below. The PAV-W/WS is also equipped with brass components that allows the device to be installed in areas subject to external corrosion. The float mechanism on the ECS Ejector Automatic Air Vent will automatically close when water reaches the vent and the redundant design eliminates the need to plumb the PAV-W/WS to drain. If the primary air vent valve allows any significant amount of water to leak past the second air vent valve will close, preventing water from discharging and provide a system pressure reading on the pressure gauge. This condition will be an indication that the primary automatic gas vent valve has failed and requires service or replacement. The pressure gauge is designed to be visible from the floor below the ECS Ejector Automatic Air Vent from a distance of approximately 30 feet. There are two available models of the ECS Ejector Automatic Air Vent: the PAV-W and the PAV-WS. The units both operate as described previously, but the PAV-WS includes a wiring connection to a monitoring circuit. A single contact rated 24VAC/DC @ 2A for electronic monitoring with an end of line resistor (EOLR) must be installed according to the wiring diagram in Figure 1 to electronically monitor the PAV-WS. A notification from the PAV-WS indicates that the pressure gauge on the bottom of the vent assembly has a system pressure reading due to a failure of the primary float valve which renders the ECS Ejector Automatic Air Vent inoperable. Engineered Corrosion Solutions• 11336 Lackland Road• St. Louis, MO 63146 Phone 1-314-432-1377• www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 1 Installation Instructions Maintenance Instructions 1 The ECS Ejector Automatic Air Vent is equipped with an isolation ball valve to be connected to the fire sprinkler system. Once the PAV-W/WS has been assembled at the provided union (see Figure 1), the contractor shall install a 1" outlet (welded or mechanical) to connect the vent assembly to the sprinkler system. 2 Install the PAV-W/WS vent assembly at the location provided by the engineering design documents in a level position at an accessible high point on the sprinkler system where trapped gas can be vented. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. 3 When electronic supervision is specified the PAV-WS must be utilized instead of the PAV-W (see Figure 1) and an addressable monitor module with an end of line resistor must be provided in accordance with NFPA 72. 4 Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. Inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. NOTE: Patented redundant float design eliminates piping the PAV-W to a drain FIGURE 1 — Wiring Diagram Vmt INSTALLATION NOTES: If Monitored By The Building Fire Alarm System, Provide One Addressable Monitoring Module To Monitor The Ejector Automatic Air Vent. E.O.L connect The Ejector Automatic Air Vent To The Addressable Monitor- ing Module. Supervise The circuit Using An End-Of -Line (E.O.L.) Resistor In Accordance Add, enable With NFPA 72. M0440. M0dlO 444. enable 44.1cc De,e The ECS Ejector Automatic Air Vent shall be inspected annually at minimum. While isolation ball valve is in the open position check for air/water leaks. Check the pressure gauge on the bottom of the vent assembly for a system pressure reading. If a system pressure reading is detected the primary vent valve may require service or replacement. While isolation ball valve is in the closed position the inspection must check for blockage in the "Y" strainer and the discharge orifice. Operating Instructions Once the fire sprinkler system has been hydrostatically tested, open the isolation ball valve on the PAV-W. Trapped gas should be expected to immediately vent from the device if the system has been re-filled with water. The isolation ball valve shall remain in the open position to allow for venting of any additional trapped gas remaining in the system that may migrate to the vent location. Water traps that would restrict operation of the ECS Ejector Automatic Air Vent can be cleared by closing the isolation ball valve and removing the "Y" strainer plug. Once the water trap has been removed, replace the "V" strainer plug and reopen the isolation ball valve. s Vent Valve Reolacement Plumbing the PAV-W/WS to drain is not required. Occasionally during venting operations a small amount of water may leak past the primary gas vent valve and collect in the intermediate plumbing. This is considered normal and not a failure of the valve. However, if inspection reveals a system pressure reading then the primary vent valve may require replacement. Please contact Engineered Corrosion Solutions for replacement parts and instructions. Engineered Corrosion Solutions• 11336 Lackland Road S St. Louis, M063146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 1" Connection to Sprinkler System must NOTE: Patented redundant float design eliminates piping vent to drain. Figure 2- ECS Ejector Automatic Air Vent Outline Drawing Primary and Seconda Gas Vent Valves "Y" Strair Pressure Gauge Figure 3 - ECS Ejector Automatic Air Vent Installed on Sprinkler System NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. Engineered Corrosion Solutions- 11336 Lackland Road • St. Louis, M063146- Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 Engineered Corrosion SolutionsT M Complete Corrosion Control.