Loading...
HomeMy WebLinkAbout2325 VIA CLEMENTE; ; FPR2018-0172; PermitPERMIT REPORT 4èity of Carlsbad Print Date: 09/29/2021 Job Address: 2325 VIA CLEMENTE, CARLSBAD, CA 92008-6803 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: THE RESERVE BLDG 9 -FIRE ALARM, REPLACE Permit No: FPR2018-0172 Status: Closed - Finaled Multifamily Fire Alarm Applied: 10/05/2018 Issued: 11/02/2018 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: FPContractor: ALL COUNTY FIRE PROTECTION INC 10965 SAN DIEGO MISSION RD SAN DIEGO, CA 92108-2431-SAN DIEGO (619) 284-4770 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov [HIGHLIGHTED SEll UL Certificates of Compliance Cut Sheets and CSFM listings: THE RESERVE AT CARLSBAD BUILDING #09 2325 VIA CLEMENTE CARLSBAD, CA 92008 Installation Company: am SINCE 1975 3163 ADAMS AVENUE SAN DIEGO, CA 92116 Ph. (619) 284-4770 CIO LICENSE #967194 FPR20I8-0172 2325 Via Clemente THE RESERVE BLDG 9- FIRE ALARM, REPLACE 10/24/2018 FPR20I8-0172 9 UL Applicant ID No: 731846.001 Service Center No: 0 Expires: 31-MAR-2019 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: POWAY, CA Alarm Service Company: (731846-001) Service Center: (731846-001) CENTRAL MONITORING CORP CENTRAL MONITORING CORP SUITE 1-4 SUITE 1-4 14231 GARDEN RD 14231 GARDEN RD POWAY CA 92064 POWAY CA 92064 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S26691 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31.MAR2019* "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" DF-52416:D • A3-20 MS-5UD(E)MS-1 OUD(E) Series) j Flre•LITeALarms Five Zone Fire Alarm Control Panel (Ten Zone Fire Alarm Control Panel) by Honeywell General The MS-5UD-3(E) is a five-zoneFACP (Fire-Alarm Control Panel) and th&MS-10UD-7(E) is a ten-zone .FACP. These con- trol panels provideliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow, devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-I0UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). le Class B)-IDC-(Initiatinj-evice - MS-5UD-3 - five IDCs. —-10UD-7 - ten ID spe- cial application power - MS-5UD-3 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). —&mp2ral or Steady aignal - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-1OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. (7.0.A_total.sy stern _current for jviSj OUD-7) Optional Dress Panel DP-51050 Optional Trim Ring TA-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. OF-524160 • 07/26/2010 -Page 1 of 4 Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Batterv_(sealed lead acijyJ Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Charger Capacity: 18 AH battery for MS-SUD-)J!Aaximum 3(E) and 26 AH battery for MS lOUD 7(E) [Two 18 Ah bat eries can be housed in the FACP cabinet Largerbtterie ) rguire separate battery box such as the BB-26 o(BB-5J) Top (- Depth= 5.207" (13.23 cm) Door = 16.821" (42.73 cm) Backbox = 16.65" (42.29 cm) Depth = I +;- Left Side Right Side Bottom Cabinet Measurements Page 2 of 4 — DF-52416:D • 07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - TB4 (and TB 6 on MS-1OUD-7 only): Alarm Zones 1 -5 on TB 4 (MS-5UD-3 and MS-10UD-7). Alarm Zones 6- 10 on T136 (MS-i OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. (E fLiRiistor: 4.7K -ohm 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. (Notification Appliance C1iiii)— TB5 (and TB 7 on MS- 101.113-7 only): Four NACs (peration:_Style Y(CIãiB)) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for M1b JD-7.(i3TöTAjnaxj- (mum per NAG t of:LiiRistor: 4.7KT6i)1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices. Form C Relays - TBB: Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-511JD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. (MS-100-7: Ten-zone, 24-volt Fire Alarm Control P1J ((includes backbox, FLPS-Lpower supply, technicaj manual, and a frame & post operating instruction sheet). MS-i OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static I (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: V Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style V (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-i OUD- 7(E) main circuit board and to J7 on the MS-1 OUD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLV: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-SIPG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-524160 • 07/26/2010 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators ......................................................................8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.OA e MS-51LID-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.72° (1.82 cm.) deep. Backbox: 19.00 (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.25° (13.34 cm.) deep. Trim Ring (TR-CE): 22.00° (55.88 cm.) high x 19.65° (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00° (50.80 cm.) high - 22.5° (57.15 cm.) wide - 8.5° (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 271C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FlreLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. NEEKINS i IIIIIIIIIIIIIACT1111118 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:1) • 07/26/2010 (Factory default relay programming) C5) Alarm' Trouble' Supervisory' II liii II Too TBS win Olin Olin OUT. Class A Converter Module ________ enable Supervisory Remove jumper JP43 to _______ , Relay when 4XTMF Cut this jumper to .121u1111111 _________ me disable Ground Fault Detection circuit (only with F .1 approval of A B in t-U) -- - JP24 module is installed Push switch down to is Kiss-off LED upgrade software Auxiliary JP10 9 Trouble Input U Cut this jumper to supervise the 4XTMF module when installed (see J4 & J5) 0 .113 ,111 ANN-SEC option card corii'iector 3 Programmable Relays Dummy load all unused circuits Nonsupervised relay contacts with 4.7KQ, V2 watt End-of-Line Contact Ratings 2.0 amps @ 30 VDC (resistive) resistors 0.5 amp © 30 VAC (resistive) Contacts shown below in normal condition (AC power with no alarm. Style Z (Class A) NAC trouble, or supervisory activity) A Fail Sate Trouble relay switches to the NC position during trouble conditions and under loss of all power. USB port for local programming using a personal computer and PK-5X Utility Notification Appliance Circuits (see note 1) Special Application Power NAC #1, #2. #3, & 94. Style V (Class B) (Supervised, Power- Limited) (See Style Z illustrated near right edge of board.) 4.7Kohm, 'A watt End-of-Line Resistor #1 NAC #2 PN71252 NAC #3 NAC #4 Class A Converter Module Remote Synchronization Output (see note 2) Special Application Power 24 VDC tittered, supervised, and power-limited. 0.040 amp maximum. Requires 4.7K ohm ELR. Initiating Device Circuits Special Application Power lDCs 1 through 5, Style B (Class B) (Supervised, Power-Limited) (See . Style 0 illustrated near right edge of board.) 4.7Kohm, 'I, watt End-of- Line Resistor PN71252 Is Basic System Connections 5-Zone Panel Notes: MS-5UD-3(E) = 2.5 amps max. per NAC MS-5UD-7(C/E)= 3 amps max. per NAC Remote Sync Output is required only for the MS-5UD-3(E): Refer to "Remote Synchronization Output" on page 34. 18 Amp Hour max. for MS-5UD-3(E) 26 Amp Hour max. for MS-5UD-7(E) 18 Amp Hour max. for MS-5UD-7C Important! Removing Ground Fault Disable Jumper JP43 voids ULJNFPA Style/Class indentifications for circuits. Remove jumper JP43 only with the approval of the local AHJ (Authority Having Jurisdiction). Special Application DC Power Outputs 24 VDC) Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-1 Resettable Power -24 VDC filtered, power-limited (0.5 amp maximum) t014— smoke detectors (lDC). Supervision 13—required. Nonresettable or Resettable Power {2 Jumper selectable by JP31 24 VDC 1- filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure T89, Terminals I & 2 as Resettable or Nonresettable Power. Resettable Power-jumper JP31 pins 2 &3 Nonresettable Power -jumper J P31 pins 1 & 2 (as shown) For more specific UL wiring information, refer to page 35. Power Supply Con L its 00 0 Battery (see note 3) 24 VDC, supervised, nonpower-limited Primary Phone Secondary Phone Active LED Active LED 0 AV JS li • • '1 0 Primary Secondary 0 DACT Phone Line Jacks Nonpower-Limited Notification Appl iance Circuits (see note 1) p B) (Supervised , Power- # illustrated flea Resistor NAC #12 #3, & ) (See Style Z watt End-Of- Une Special Aplication Power Style V (Class r right edge of board.) Dummy load all unused circuits Limited 4.7Kohm, 1/2 PN 71252 NAC #3 NAC Initiating Device Circuits progmmable Relays with 4.7K, Vu wall E Cl special Application Power NAC #1 NAC #2 lass B) (5ue0Cs 1 through 5. Style B Nonsupervis relay prosed Power- Contact Ratings (resistive) contacts resistors Limited) (see Style D 2.0 amp 5 @30 VD illustrated near right edge of board.) 0.5 amp i 30 VAC (resistive) Style Z (Class A) NAC 4.7K0hm, w watt End-of-Line Resistor Contacts shown below in normal PN 71252 condition (AC power with no alarm, Remote trouble, or supervisory activity) Synchronization A Fail Safe Trouble relay switches to Output (see note 2) the NC position durin trouble oorc Special Application Power conditions and under loss of all 24 VDC filtered, supervised, power. and power-limited. 0.040 amp maximum. Requires 4.7K (Factory default relay programming) ohm ELR. ii Alarm " Trouble" supeMsory" 111111111 Basic System Connections 10-Zone Panel Notes: MS-10UD-3(E) = 2.5 amps max. per NAC MS-i OUD-7(C/E) = 3 amps max. per NAC Remote Sync Output is required only for the MS-1OUD-3(E): refer to "Remote Synchronization Output" on page 34. 18 Amp Hour max. for MS-1OUD-3(E) 26 Amp Hour max. for MS-10UD-7(E) 18 Amp Hour max. for MS-10UD-7C Important! Removing Ground Fault Disable Jumper JP43 voids ULJNFPA Style/Class indentifications for circuits. Remove jumper JP43 only with the approval of the local AI-(J (Authority Having Jurisdiction). Initiating Device Circuits Special Application DC Power Outputs 24 VDC) Nonsupervised, power-limited circuits Supervise with a power supervision relay EOLR-i Resettable Power -24 VDC filtered, power-limited (0.5 amp maximum) t014__ smoke detectors (IDC). Supervision 1.3 required. Nonresettable or Resettable Power {2 Jumper selectable by JP31 24 VDC 1 filtered, power-limited (0.5 amp maximum). Supervision required. Nonresettable Power suitable for powering smoke detectors. Configure TB9, Terminals 1 & 2 as Resettable or Nonresettable Power. Resettable Power-jumper JP3i pins 2 Nonresettable Power-jumper JP3I pins 1 & 2 (as shown) For more specific UL wiring information, refer to page 35. Power Supply 00 ___ _______ o o ___ _o - - o '185 TB4 TB? ThS132 '18$ °r ro ram ram 9 9 Class A Converter Module ,Cut this jumper to enable supervisory J2 IIuuuuIIJ7 / Relay when 4XTMF illililil Remove jumper JP43 to JP24 module is installed disable Ground Fault a Detection circuit (only with approval of AHJ) El Battery (see note 3) 24 VDC, supervised, nonpower-limited lBS swi Push switch down to upgrade software J5 Kiss-off LEO Auxiliary • JP3O Irai Troubte Input Cut this jumper to supervise 0 the 4XTMF module when installed (see J4 & J5) 0. 313 Jil ANN-SEC option card connector Primary Phone Secondary Phone Active LED Active LED 0 Primary Secondary C DACT Phone Line Jacks Nonpower-Limited Class A Converter Module USB port for local programming using a personal computer and PK-5X Utility El Power Supply Calculations Calculating the System Current Draw Table 7.3 contains three columns for calculating current draws. For maximum output current avail- ability per circuit and per panel, refer to Section 1.2, "Specifications", on page 15. For each col- umn, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 121. Calculation Column I Calculation Column 2 Secondary, FiAl niCUrrent CalculationColumn 31-1 (ondary,Non-FireAlarmi Device Type Primary, Non-Fire Alarm Current _....._.j Current (amps) (amps) (amps) Qty I X(current I Total X (current draw] Qty I I Total Qty I I X[current I Total I draw]= = I I draw] I Main Circuit Board MS-5UD X[O.11O]= X[O.214]1' 2 X[0.110]= or 1 1 1 (MSoUD) X[0.133]= i82l12= CAC-5X [ ] X[0.001]= [ ] X[0.001]= [ I X[0.001]= 4XTMF F ] X[O.005]= [ ] X[0.011]1= F ] X[0.005]= 1 max. 1 max. 1 max. ANN-SEC card [ ) X[O.003]= [ ] X[0.003]= [ ] X[0.003]= 1 max. 1 max. 1 max. ANN-80(C) IL ] X[O.037]= I ] X[0.040]= 1 ] X[0.015= ANN-I/O ) X[0.035]= I ] X[O.200]= I X[0.035]= ANN-RLY [ ] X[O.015= I ] X[O.075]= I J X[0.015]= ANN-(R)LED L ] X[O.028]= I ] XO.068]= I ] X[0.028]= ANN-S/PG ] X[O.045]= ] X[0.045]= ] X[O.045]= 2-wire Detector [ I X[ 4 [ ]b X[0.040] ] X[ ]4 Heads 4-wire Detector [ ] X[ 4 b X[0.040] F ] X[ ] Heads Power [ ] X[O.025]= [ I X[O.025 I ] X[O.025] Supervision Relays6 I NAC#1 [ ] X[ 1= NAC#2 I ] X[ I NAC#3 NAC #4 Current Draw [ from TB9 (nonalarm) Sum each column1 for Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm = totals Table 7.3 System Current Draw Calculations If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. An ANN-LED is supplied standard with the MS-5UDC and MS-i OUDC. Refer to the Device Compatibility Document for standby current. Enter the number of IDCs used minus one. Must use compatible listed Power Supervision Relay. Total current draw listed above cannot exceed 3.25 amps for the MS-5UD-3(E), 3.28 for the MS-10UD-3(E), 7.25 for the MS-5UD-7(C/E), and 7.28 for the MS-10UD-7(C/E). 120 MS-5UD & MS-lOUD Series Manual-PIN 52626:C5 7/16/2014 NFPA Standard-Specific Requirements The following figure illustrates an example of Central Station/Remote Station Reporting using a 411UD. The relay contacts from the MS-5UDIMS-1OUD maybe used to trip any dialer UL listed for Central Station/Remote Station Reporting Services. 4IIUD (non-supervised, power-limited) Figure B.1 MS-5UD/MS-I0UD FACP Connection to 4IIUD 4IIUD FACP Alarm T132-1 T138-1 T132-2 TB8-3 Trouble TB2-3 TB8-4 TB2-4 TB8-6 Supervisory TB2-5 TB8-7 T132-6 T68-9 Table B.1 411 U Connections to FACP 128 MS-SUD & MS-lOUD Series Manual— PIN 52626:C5 7/16/2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-0075:0214] Page 1 of 1 CATEGORY: (7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)) LISTEE: (FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-16J Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-5UD-3,_MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E,(ti-10UD-) MS-10UD-7C AND MS10-UD-7E(Fire alarm control units The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANNSEC; Secondary ANN-BUS Module *lpDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires) 019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG=7FS) TIILTE- X L /'NTG7L ôi] CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD COMMERCIAL FIRE PRODUCT FEATURES 1. (Certified for use on Verizon's LTE network)for long, sunset- free installation. I Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LIE-V can also be installed as a backup path and upgraded to sole path at a later date. j Dar dJj'I TIrd M a 3 _ ing ceiiLl lar easy with a secure Internet postal. The stTightt.orw1 web int'Tface allows secT{rity dealers and centThl stations to quiclZly and refficiently access Telguad based seLices 4/7. This a ,ancetooI has multJeyel user authorization ad p.ovides total oJitagement of UIListedguarjdr!!lar alarm corn rntin I cato rs. ffelquandIG'EllularlSer,vicel Verizon LTE network coverage 1foall -1 Oar units. Telguads ornmunition Gëiter is 1!JL corn I i.t1al pLo..d es seam le connetivity between the alarm panel, the Telguard family of Poducts and the centT] station. Tel7d IEhnical Support p'iaes a siTle po111of contact for both cellular se/ice ancall lei ,questi ons, UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems For the most current product specifications and UL Listings Visit www.Telguard.com. TG-7FS LTE-V P/N: TG7LVFO1 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta. GA 30339• USA 800-229-2326, Option 5• www.Telguard.com . copyright ©2017 Telular Corporation. All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:11) Page 1 of I CATEGORY: (7300 ---FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES) LISTEE: [TELULAR CORP Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *TG7LV001 *TG7LVA01 tTG7LVF01)and TG-KIT, digital cellular communicator) LsyiJModels are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. N *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 [une 30, 201) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division BW-DocBox BW-DocBox (15"W x 13"H x 4" D) includes: Three labels "Fire Alarm Documents" "As-Built Permits" "Test and Maintenance Documents" An adjustable bungee allows you to fit various sizes of binders, documents, smoke-cans, etc. A door bracket holds two CDs, three sets of keys and more documents A cam lock with two keys BW-DocBox2 (11"Wx 15"Hx 4"D) Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adjustable bungee and a lock with two keys. 17, Don't see the box you want? Customization, special colors, and/or silk-screening of logos are Call us or visit our website available for quantities of 25 or more. (requires lead time) 800-473-0213 E-mail: info@mierproducts.com f SVSIL ñfII $ Si'niso" 5600 Series)____ Mechanical Heat Detectors) System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang —3.5Thnd 4- Octagonal - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings LISTED APPROVED S2101 3016008 C0630 7270-16530167 Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ________ listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (900C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identity the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 1350F (570C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Operating Voltage! Contact 6-125VAC / 3A Ratings 6-28VDC / 1A 125 VDC / 0.3A 250VDC/0.1A InDutTerminals 14-22 AWG 111 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information (135°F (7OJ Fixed Temperature /Rate-of-Ri) L50 feet x 50 feet (15.24m x 15.2m 5602 Single Lettering 194°F (90°C) Fixed Temperature /Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature IRate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature /Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. of~Sy57EpJJ 3825 Ohio Avenue • St. Charles, IL 60174 02013 System Sensor. for current product into,rnof on, includng the latest version of ads data street. SEALcOR° Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specUicaUons subject to change wrout rroce. Vbt systemsensor.ccm www.systemsensor.com sP0530001 • 7113 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (70-1653:0167) Page 1 of 1 CATEGORY: (770 -HEAT DETECTOR) LISTEE: (System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL) 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models 5601, P,)5602, 5621, and 5622(ombination fixed-temperature and rate-of-rise and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical(heat detectors.) Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models 5601, 5601P, 5603, 5621, & 5623 have a fixed temperature of 135°F. Models 5602, 5604, 5622, & 5624 have a fixed temperature of 194°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details and UL directory for dimensions. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I Dual Action BG-12LOB (2) Flre•LITe arms Document 51378 Revision A ECN 00-215 06/16/2000 Description The BG-12LOB Pull Station is a non-coded manual pull station which provides a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The pull station is a dual action model equipped with a key lock reset, an approved outdoor gasket, and an accompanying outdoor backbox. It is UL listed and meets the ADA requirement of a 5-lb. maximum pull down force to activate. Operating instructions are molded into the handle. Molded terminal numbers can also be found adjacent to the wiring terminals. BG-12LOB The features of the pull station include Dual-Action operation, Key-Lock Reset function, Screw Terminal Wire connections, outdoor use gasket, a WBB outdoor approved 4-inch backbox, and a sealed switch with gold-plated switch contacts. Note: The BG-12LOB is applicable with the WP-10 backbox in retrofit applications. To meet UL requirements for outdoor use, the BG- 12L0 Pull Station must be mounted to the WBB or WP-1O Backbox to create the BG-I2LOB model. Switch Contact Rating FACP Circuit (Terminals 1 & 2): Rated to .25 Amp at 30 Volts (AC or DC). Door Attachment If the door becomes detached, complete the following steps to reattach the door to the backplate. The door cannot be connected to the pull station if the unit is mounted to a backbox. With the door and backplate aligned and keyed' together, slide the holes down onto the posts. Position the door and backplate side by side in the full open position. (i.e. 180-degrees with respect to each other.) With the backplate position fixed, move the door behind the backplate, as shown in the illustration, part A. Align the hinge posts and holes by bringing the door up to meet the backplate, paying particular attention to the 'keying' that occurs when the door's post hole is aligned to the backplate's hinge post. Refer to the illustration, part B. With the two pieces aligned and 'keyed' together, slide the holes down onto the posts. Refer to the illustration, part C. Holding the backplate, close the door slightly to lock the door and backplate together. II HM I woo 1L Closing the door slightly locks the door and backplate together. Door mated to Backplate at this stage. BC-i 2LOB Pull Station (Shown Activated) Wiring Instructions Surface mount the supplied Outdoor Backbox (WBB) using the side flanges incorporate into the backbox design. The box can be positioned to allow conduit connection from any side. The pull station will mount in any position desired. Before mounting the pull station, pull all necessary wiring through the backbox. Remove the correct amount of wire insulation. The pull station's backplate is molded with a strip gauge to measure the amount of insulation to be removed. Connect the wiring from the fire alarm control panel's Initiating Device Circuit (IDC), or any previous device on the IDC to terminals 1 and 2 located on the pull station's terminal strip. Connect the next device on the IDC or End- of-Line Resistor (ELR) to terminals 1 and 2. Note: Maintain consistent polarity with all connections throughout the IDC. Outdoor Stations Install the BG-12LO with a listed, outdoor-approved backbox (WBB or WP-10) to meet UL requirements for outdoor use. Without one of these backboxes, the BG-1 2L0 is not listed for outdoor applications. Use the four supplied 8-32 x .375' mounting screws to attach the Pull Station to the outdoor- approved backbox. BG-i 2L0 + WBB = BG-12LOB Next Device I Outdoor-Use Gasket (Does not cover any user-serviced connections) Operation To activate the dual-action station, first push in the handle, and then pull the handle down. The handle locks into the activated position. The word 'ACTIVATED' appears after the handle is pulled down. The pull station remains in the activated position until reset with the key lock. Reset the BG-12LOB by inserting the key into the lock and turning it 14 turn (counter-clockwise). Open the door until the handle returns to the 'NORMAL' position. Close and lock the door. Closing the door auto- matically resets the switch to the 'NORMAL' posi- tion. Note: Opening the pull station door will not activate or deactivate the FACP alarm switch. From FACP IDC CAUHON Install the pull station in accordance with the supplied instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the Authority Having Jurisdiction (AHJ). Conduct regular testing of the devices using appropriate NFPA standards. Fire-Lite is not responsible for devices that have not been properly installed, tested or maintained. For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 inches (12 1.92cm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach height allowed is 54 inches (137.16cm). Document 51378 Revision A ECN 00-215 06/16/2000 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. t71 -0075:0184) Page 1 of I CATEGORY: (7150 -- FIRE ALARM PULL BOXES) LISTEE: (FIRE-LITE ALARMS INC.One)Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHorteywell.com DESIGN: Models BG-12, BG-125, BG-I2NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12P5,_BG-I2LSP, BG-125P, BG-12LR, BG-12LRA, BG-12LAO, BG-1 2LAOB, BG-1 2-LO,(BG-12LOB,)BG-I2LPS, BG-1 2LPSP, BG-1 2SL, UT-PSi and UT-PS2(fe alarm pull boxes)The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-I2LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB arn4BG-12LOB are intended (outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed - the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires) (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (GHLF 24 VDC Series__ (L©w eci Ae s) 24 VDC 520 Hz square wave audible 24 units per carton, 28 pounds per carton Applications The GHLF is a high quality, low profile, low frequency audible appliance that offers f" a dependable audible alarm with a low current draw. The GHLF is ideal for any I occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave, temporal 3 tone. Ajumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide' feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate' - Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire protective systems and is warranted for three years from date of purchase. Standard Features Nominal voltage 24 VDC Unit Dimensions: 6-1/8" (15.55 cm) high x 5-1/2" (13.97 cm) wide x 1-5/8' (4.13 cm) deep Super-Slide Bracket - Ease of Supervision Testing Checkmate' - Instant Voltage Verification Synchronize horn with Gentex GTSM Synchronization Control Module Prewire entire system, install mounting bracket, then install signals Input terminals accept 12to18AWG Produces a 520Hz square wave, temporal 3 tone Jumper selection for normal or loud dBA Temporal 4 pattern available when used with Gentex GTSM Synchronization Module Temporal 4 520Hz measured per ANSI/UL 2075 Tamperproof re-entrant style grill and locking screw (optional use) Faceplate available in red or off-white Product Listings SIGNALING c®uS ? LISTED ANSI/UL 464 Listed CAN/ULC S525 Listed CSFM: 7135-0569:0148 Product Compliance NFPA72 IBC/lFC/lRC Quality Management System is certified to: ISO 9001:2008 Model Part Number Nominal voltage (VDC) L94-053O-0O GHLFR 904-0531-002 24 R = Red Faceplate, W= White Faceplate. All units are plain (no lettering). DO NOT PAINT -' 2) O9r_ 0 0 3 i Led H. ud all 0 ~Fc:: 0 0 0000 2i UI oJ It 3 Horn Decibel Levels: ______________________ Horn Current Ratings Reverberant Room (dBA) Over Input Voltage Range of 16-33V (mA) Regulated Regulated Minimum Minimum 24VDC 24VFWR 4VD Max. 24VFWR Regulated 24VDC Max. Regulated 24VFWR 24VFWR SPLat loft. SPLat lOft. Per M.0leratin Operating 24VDC Max. Per Operating Operating Current Operating Operating Operating Max. Operating ANSI/UL464 ANSI/UL464 Current (LOUD) Current (NORMAL) (LOUD) Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) 77.8 dBA 79.8 dBA i1AI 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA t52OH ________ Temporal 4 81.5 dBA 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA 520 Hz* ____________ Temporal 4520Hz measured per ANSI/UL 2075 I 1-5/8' 4.2cm 11 Notes Operating temperature: 32° to 120°F (0° to 49°C) The GHLF is not listed for outdoor use For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating This appliance is not recommended for use on coded or pulsing signaling circuits The four pulse temporal pattern (temporal 4) can only be obtained on this product when used in conjunction with the Gentex GTSM synchronization module See GTSM control module manual (550-0632, manual issue date (02-01-15) for synchronization module wiring diagrams. GTSM manual can be obtained at www.gentex.com/fire, or call Gentex Corporation at 1-800-436-8391 UL Listed Control Panel Supervised Signal Circuit \ Signal Signal S.H+14 S+S*S IH - CND OF LVI! aesisloe GHLF - Low Frequency Audible Signal GHLF 24 VDC Series Low Frequency Audible Signal Gentex Super-Slide® Mounting Bracket Architect & Engineering Specifications Allows the installer to prewire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap-in-place installation. Gentex Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the 5+ and S- locations although access is provided to other locations. Notice: Care should be taken to not short the test probes. The alarm horns shall be Gentex model GHLF. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems ANSI/UL 464 and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 d8A as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The GHLF shall be mounted on the wall or the ceiling. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7135-0569:O148J Page 1 of 1 CATEGORY: (7135--AUDIBLE DEVICES) LISTEE: (Gentex Corporation 10985 Phicago Drive, Zeeland, MI 49464 Contact: Keiffer Sestric (616) 392-7195 Fax (616) 392-4219 Email: keiffer.sestric@gentex.com DESIGN: (Model GHLF low frequency horn i) The model may be followed by a letter indicating product color. *Models GHSLF-15, GHSLF-1 10 and GHSLF-177_low frequency horn/strobes. *Horn/strobes models may be followed byor -R(eor red). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VdcNFWR *Model GHSLF-15 15 candela fixed *Model GHSLF-110 110 candela fixed *Model GHSLF-177 177 candela fixed INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a low frequency horn or* low frequency horn/strobe when used with a separately listed electrically compatible fire alarm control unit. Horn/strobe models for wall mount only. All models are for indoor use only. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. *Rev 07-11-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I RSSP REMOTE PLATE Description The Wheelock Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higher dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Features Approvals include: UL Standard 464, Factory Mutual (FM), Califor nia State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures 6" and 10" shell sizes in 12 or 24 VDC models Series RSSP Sync/Non-Sync retrofit plates are used in • Integral RFI suppression to minimize included noise on the NAC conjunction with the Series MB Motor Bell when combination circuit appliances are required. The Series RSSP retrofit plates are • Mounting options for surface, semi-flush, outdoor, and concealed available with either Multi-Candela or single candela strobes conduit installation and easily mount to a 4" square or Wheelock SBL-2 backbox. • Built-in trimplate makes semi-flush mounting simpler and less All Series RSSP strobe appliances meet or exceed the expensive requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard forAccessible and Usable • Screw terminals permit fast in-out field wiring of #12 to 18 AWG wire Buildings and Facilities), ADA (Americans with Disabilities Act) • Polarized for DC supervision of NAC circuits and UL Standard 1971 (Signaling Devices for the Hearing Impaired). • Operates on filtered or unfiltered DC The Series RSSP retrofit plates may be synchronized when • For combined audible (bell) and visual signaling, convenient retrofit installed with the Wheelock Series DSM, Sync Modules or plate assemblies are available with Multi-Candela or Single candela Wheelock Power Supplies with Wheelock patented sync strobes (Refer to Fire Alarm Products Catalog for Series RSSP protocol. Wheelock synchronized strobes offer an easy way Sync/Non-Sync Strobes specifications and technical information) to comply with ADA requirements concerning photo-sensitive epilepsy. Ordering Information Model Number Order Code Shell Size lnputVoltage (VDC) AverageRMS Current UL Max* dBA lOFt Mounting Options MB-G6-12-R 3942 6" 12 0.060 0.090 92 0.040 DE,J,KNOPRS MB-G6-12-S 4221 6" 12 0.060 0.090 MB-G6-24-R 3941 6" 24 0.030 0.040 MB-G6-24-S 4222 6" 24 0.030 0.040 MB-G1'0-12-R 3944 10" 12 0.060 0.090 MB-G10-12-S 4223 10" 12 0.060 0.090 03 (öo (óTöo MB-GI0-24-S 4224 10" 24 1 0.030 NOTES: Typical dBAat 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). O 24v units). For audibles the max current is usually at the maximum listed voltage For strobes the UL max current is usually at the minimum listed voltage (16v for MEA APPROVED (33v for 24v units). For unfiltered FWR ratings, see installation instructions. E5946 151-92-E 7135.0785:113 Architects and Enaineers Specifications (the alarm appliances shall be WheelOck Series MB vibrating Motor Be)or apd eqiaL They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6' or 10" diameter.ound output at 10 feetshallb92.dA) The bells shall incorporateaperrnanentmanet motor and suppression circuitry to minimize RFI a built itr1p1te4!Lsemi flush) (mounting to a standard 4" square backbox, or surface mounting to Wheelock's)indoor For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Model Number Order Code Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC UL Max* Mounting Options RSSP-24MCW-FR 9402 24 15/30/75/110 .041/.063/.109/.140 .060/.092/.165/.220 D,E,Z RSSP-241575W-FR 7793 24 15 (75 on-axis) .060 .090 D,E,Z RSSP-121575W-FR 1 7798 12 15 (75 on-axis) .152 .255 D,E,Z * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibies the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Fig. 2 Retrofit Strobe Plate Models (RSSP) AUDIBLE STROBE I I FROM - - 10101PRECEDING APPUANCEOR + PACP OR APPLIANCE + FROM - TO NEXT PRECEDING - STROBE OR STROBE OR + + EOLR FACP Wiring Fig. I Bell Models TO NEXT FROM ____________ APPLIANCE PRECEDING OR END-OF-LINE APPLIANCE RESISTOR OR FACP (EOLR) Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. rEAI4 I.'flThr'i WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S1500 MB 06/11 Cooper Notification is Wheelock* (MEDCJ SAFEPATH WAV Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7135-0785:0113) Page 1 of 1 CATEGORY: 7135 --(AUDIBLE DEVICES) LISTEE: (Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Model MB series bells)and Model MBS series bell/strobes.peIs MB are suitabIe for ) (outdoor use when used with Model WBB backbox) Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires) (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division COIP1TR4N 'Carporation 17 RISER FIRE ALARM CABLE FLAME RETARDANT PVC JACKET UL TYPE FPLRICMRJCL3R C(UL) CMG 300 VOLT APPLICATIONS: Fire Alarm, Signal Monitor/Detection Audio or Control Circuits - 22 AWG Solid Bare Copper, Insulation Thickness: .006" Part No. No of Cond Jacket Thickness Inches Nominal Diameter Inches 4304 2 .014 0.120 18AWG Solid Part No. No of Cond Jacket Thickness Inches Nominal Diameter Inches 4186 4 .014 0.168 4188 1 6 .014 0.202 4190 8 .014 0.220 4192 10 .014 0.260 16 AWG Solid Bare Copper, Insulation Thickness:.009" Part No. No of Cond Jacket Thickness Inches Nominal Diameter inches 4234 2 .014 .166 4236 4 .014 .194 14 AWG Solid Bare Copper, 1nsulation Thicknes 01' - Part No. No. of Cond Jacket Thickness Inches Nominal Diameter inches 4241 4 .014 .245 CHARACTERISTICS: Operating Temperature: -100Cto+800C Voltage Rating: 300 Volts Color Description: Chart F, Page 42. Jacket Color: Red Product Description: Solid bare copper Insulation: Semi-Rigid PVC Nylon rip cord for ease of jacket stripping Jacket: Flame Retardant PVC Specifications: UL Type FPLRJCMRICL3R C(UL)CMG (14 and 12 AWG FPLRJCL3R only) Passes UL 1666 Riser Flame Test RoHS Compliant 12 AWG Solid Bare Copper, Insulation Thickness: .011" Part No. No. of Cond Jacket Thickness Inches Nominal Dianieter Inches' 4511 2 .014 .242 I&W LISTED www.comtrancorp.com