Loading...
HomeMy WebLinkAbout3207 GREY HAWK CT; 150; FPC2017-0233; Permitt('( ity of PERMIT REPORT Carlsbad Print Date: 10/13/2021 Permit No: FPC2017-0233 Job Address: 3207 GREY HAWK CT, # 150, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2210150100 Track #: Applied: 08/15/2017 Valuation: $175,000.00 Lot #: Issued: 08/31/2017 Occupancy Group: Project #: Finaled Close Out: 09/09/2020 #of Dwelling Units: Plan.#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: CRB SUITE #150 -FIRE ALARM TI FPContractor: LOW VOLTAGE FIRE INC 1090JOSHUA WAY, #UNITA VISTA, CA 92081-7800 (760) 598-4110 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To pate: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL L wV,Itcçr i n t g r ci t s y s t n-i s FIRE ALARMS SOUND DATA S MEDIA S SECURITYS CCTV ACCESS CONTROL FIRE ALARM SYSTEM CRB SUITE #150 T.I 3207 GREYHAWK COURT CARLSBAD, CA. 92010 FPC20I7-0233 3207 GREY HAWK CT UNITI5O LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: C10, C16 # 791832 Low4PaItage ,ntcgrotod systoms PHONE: (760) 598-4110 FAX: (760) 598-4107 PART DESCRIPTION MANUFACTURER CSFM LISTING D4120 DUCT DETECTOR SYSTEM SENSOR 3242-1653:0207 RTS-151 REMOTE TEST SWITCH, SYSTEM SENSOR 7300-1653:0212 AMM-21F MONITOR MODULE GAMEWELL, FCI 7300-1703:0102 Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA '• LICENSE NO. CIO, C16#791832 email: info @ sdlvis.com SYSTEM SENSOR D4120 Duct Smoke Detector The lnnovairFlexTM Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. /7 innove-% i/* S S Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ftimin to 4,000 ftfmin (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-tan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Agency Listings @ <~> 0 LISTED APPROVED S911 3033744 7272.1653:0203 The InnavairFiex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The lnnovairFlex housing provides ample wiring space, a 3/4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 lnnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The lnnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. . lnnovairFlexTM Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex° 04120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. --... .... - .- .---.... 1 Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm).Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: D4120 & D4S: —4° to 158°F (-20° to 7O C); 04P120: —40° to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & NS: —22° to 158°F (-30° 1070°C); D4P120: —40° to 158°F (-400 to 70°C) Operating Humidity Range: 0% to 95% /elative humidity non-condensing 11 Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max; 270 pF max. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with RTS151) .03 to 0.3 sec. .03100.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. . 35 sec. max. 35 sec. max. Alarm response time: 15 sec. . 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: . . 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz 7777777 -- Alarm initiation contacts: 2.OA @ 30 VDC (resistive) . (SPST) Alarm auxiliary contacts: bA @30 VDC (resistive); 10A@ 250 VAC (resistive); ½ HP @240 VAC; 1/. HP @ 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 2.OA @30 VOC (resistive); 2.OA @ 125 VAC (resistive) Device, . Standby . Trouble . Alarm : APA151 12.5 mA n/a 30mAMax. MHR/MHW . 0 mA n/a 29 mA Max. RA100Z 0 mA . n/a . 12 mA Max. : RTS151/RTS151KEY 0mAJ12mA n/a . I12mAMax.1 RTS2/RTS2-AOS -. 3.0mA max 16 mA Max. with strobe: 55 mAmax; without strobe 30 mA max Note: Any combination 91 accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output . . Installing the InnovairFIex Sampling Tube . . . .1 The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasinq the front or rear lnckinq tab (front locking tab shown below right). r (1 I HVDSOOSOO I WirinQ for 4-wire Duct Smoke Detector and Accessories I POWER INPUTS (NOTE I) I I POWER INPUTS (NOTE 1) 4VAC/D1 I r4" 1 ri H & & &I 9 10 I 9 10 I OR I I OR I I AUXILIARY CONTACTS . I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB AUXA AUXB JN 1 , , C N N 797 SUPERVISORY CONTACTS I SUPERVISORY CONTACTS I (NOTE 3) I (NOTE 3) I H Sum. sup .o. UUFM LISTED 3 14 3 14 4 WIRE CONTROL PANEL +,- II II ALARM 4 ALARM C. ALARM 4 ALARM C. ALARM INITIATION -r INITIATION INITIATION CONTACTS CONTACTS LOOP \ (NOTE 4) (NOTE 4) LALARM J5 ALARM N.O. N.C. -----------J ------------J FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER '1 NOTE 1: 24V Power Inputs accept a non-polarized 24V0C or 24VAC 50-60Hz. 120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. Please refer to the corresponding installation manual for accessory wiring diagrams. NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. S Important Notes on 2:1 Sensor-to-Power Capabili 2:1 sensor-to-power capability is not available for all InnovairFIex models. The feature is only available on the 04120 4-wire conventional models. 2:1 sensor-to-power capability can be enabled using one 04120 and one 04S, or two D4S and one D4P12O. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX— terminal on unit 1 t the INT/AUX- terminal on unit 2 and so on. Up to 50 D4120 units, 50 04P120 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120 units. Therefore, when using the interconnect feature a single OH100ACDC can drive either 9 DHi0OACDCs or 27 04120 units. - * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. HVDSOQ500 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our, duct smoke detectors, all duct smoke detector accessories are UL listed. I - RTSI51 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 As, RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS S Ordering Information 2051 4-wire conventional photoelectric sensor head MHR Mini Horn, Red OST1 Metal sampling tube duct width up to 1 f (0.3m) MHW Mini Horn, White OST1 .5 Metal sampling tube duct widths 1 ft to 2 ft P48-21-00 End cap for metal sampling tubes (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft RA100Z Remote annunciator alarm LED (0.6to1.2m) DST5 Metal sampling tube duct widths 4 ft to 8 ft FITS 151 Remote test station (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft RTS1 51 KEY Remote test station with key lock (2.4 to 3.7 m) APA151 Remote annunciator with piezo alarm RTS2 - ADS Multi-signaling accessory with add on strobe DH4000E-1 Weatherproof enclosure 3825 Ohio Avenue • St. Charles, IL 60174 ©2ol2Sys1en Sensor. specificad'-" W . Phone: 800-SENSOR2 • Fax: 630-377-6495 Product SENSOR''.....Y Hvos00500. II'S www.systemsensor.com O Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Velociti® Series ANN=21' Description The Gamewell-FCI VelocitiO Series, addressable monitor module AMM-21F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry con- tacts may be made addressable when connected to the AMM-2F module. The Velociti® Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-217 module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterfiow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. VelocitP is registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Addressable Monitor Module AMM-2F Features 1~1\_ Compact size allows easy installation Class B, Style B, initiating circuit 40 Ohm line resistance for each initiating device circuit Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% (non-condensing) End-of-Line Resistance: 47K ohms Dimensions: 1.3" Lx 2.5" W x 0.5" 0 (3.3 x 6.4 x 1.3 cm) Ordering Information Part Number Description AMM-2F Addressable monitor module, single circuit, Style B, Class B SIGNAUNG ®<>MEA LISTED APPRED AM-led 51949 3023594 227-03-EVOLIV 7300-1703:0102 isogoo GAMEWELL-FCl 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 2013 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. E page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0207 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (WI OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywelI.com DESIGN: ModelslD4l2ol D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD412OX, LD4120H, D4S, D4P120, CD4P120 LD4P120X, LD4P120H, TD4C, PD4120, YD4120, YD4P120, and AD4P120 four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 2D51 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4c LD412OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, 24 VAC, 120 VAC (except Models *TD4C LD412OX, LD4120H, LD4P120X and LD4P120H *do not have 120 VAC rating). INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-27-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE AL Page 1 of 1 LISTING No. CATEGORY: LISTEE: RATING: INSTALLATION: MARKING: APPROVAL: 7300-1653:0212 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.KireyevhoneywelI.com Models jRTS151,IRTS151KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. Refer to the installation manuals. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: 7300-1703:0102 - Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models AMM-4, *AMM..4F AMM-2 and AMM-2F monitor modulesland Models AOM, AOM-2, AOM-2R, *AOM2RF AOM-2S and *AOM2SF control modules. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules FORMERLY: 7300-0694:178 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other '9 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division