Loading...
HomeMy WebLinkAbout3209 HARDING ST; ; FPC2017-0126; Permitrcity of PERMIT REPORT C du Print Date: 10/13/2021 Permit No: FPC2017-0126 Job Address: 3209 HARDING ST, CARLSBAD, CA 92008-2417 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class Fire Alarm Parcel #: 2041000500 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan check #: Plan Check #: Applied: 05/15/2017 Issued: 06/20/2017 Finaled Close Out: 08/12/2021 Inspector: Final Inspection: Project Title: Description: PINE AVE PARK COMMUNITY CENTER -FIRE ALARM (NEW) INSTALLATION OF NEW FIRE ALARM SYSTEM FOR 2-STORY COMMUNITY CENTER FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL FOR PINE AVE. PARK COMMUNITY CENTER 3096 HARDING STREET CARLSBAD, CALIF. 92008 FPC20I7-0126 3096 Harding ST SimplexGrinnell LP 3568 Ruffin Road tqco San Diego, California 92123 P.. 858-633-9100 F: 858-633-9101 SimplexGrinne/I w'm,.simpIexg,1nnelI.com Fire Alarm System Products City of Carlsbad Parks and Recreation Dept. Pine Ave Park Community Center 3096 Harding Street Carlsbad, California 92008 Qty Model No. Description C.S.F.M. No. 1 4007-9101 Fire alarm control panel 7165-0026:0378 1 4606-9205 Annunciator 7300-0026:0382 2 2081-9274 12VDC 10AH rechargeable battery N/A 1 4099-9004 Manual Pull Station 7150-0026:0224 4 4098-9714 Photo sensor 7272-0026:0218 1 4098-9733 Heat sensor 7270-0026:0216 5 4098-9792 Sensor base 7300-0026:0217 9 4098-9756 Duct sensor housing 3240-0026:0241 9 4098-9856 Sampling tube, 49" N/A 9 2098-9806 Remote test switch w/LED 7300-0026:0150 9 4098-9843 Encapsulated Relay 7300-1004:0101 4 4090-9001 Supervised 1AM 7300-0026:0223 5 4090-9002 Relay lAM 7300-0026:0223 3 4906-9103 Strobe, multi-CD, wall, white 7125-0026:0316 9 4906-9104 Strobe, multi-CD, ceiling, white 7125-0026:0316 1 4906-9129 Horn/strobe, multi-CD, wall, white 7125-0026:0317 5 4906-9130 Horn/strobe, multi-CD, ceiling, white 7125-0026:0317 2 4906-9141 Horn/strobe, multi-high-CD, wall, white 7125-0026:0333 3/20/2017 REV.#: 0 PROJECT #: 997526601 Safer. Smarter. TYCO.TM Ll S Simplex 4007ES Fire Control Panels UL, ULC, CSFM Listed; 4007ES Hybrid, Fire Detection and Control Panel with FM, NYC Fire Dept Approved* Addressable and/or Conventional Initiation I ik'i.-i Flexible standard combination of conventional and addressable initiation satisfies a wide variety of new and retrofit applications 4.3" (109 mm) Diagonal color touchscreen display: Convenient and intuitive user interface provides detailed system status and individual point information Supports dual language selection, including unicode character languages A custom background display appears when operation is normal (see page 6 for details) Eight Point Zone/Relay Module: Each point is selectable as an DC input or Relay output, Class A 1DCs require 2 points (one out and one return); one module is standard, up to 3 additional modules can be field installed for a total of 4 eight point zone/relay modules per system Each point on the DC/Relay Module can be configured as a control relay rated 2 A @ 30 VDC (resistive) as either normally open or normally closed Can be powered directly from the power supply or through the optional 25 VDC Regulator Module IDC end-of-line resistor value can be selected from a wide range of resistance values for retrofit convenience Electrically isolated lDNet+ addressable initiating device SLC: Provides built-in short circuit isolation for monitoring and control of lrueAlarm analog sensors and IDNet communications monitoring and control devices; for use with either shielded or unshielded, twisted or untwisted single pair wiring; outputs are Class A or Class B Standard panel SLC provides up to 100 addressable points; optional additional loop expansion modules provide an additional isolated loop with short circuit isolation for the 1DNet+ channel; each loop expansion module also provides an additional 75 addressable points to the IDNet+ channel capacity for a total of up to 250 addressable points Power Supply Features: Four Notification Appliance Circuits (NACs) selectable as Class A or Class B with 6 A total available current NAC end-of-line resistor value can be selected from a wide range of resistance values for retrofit convenience Additional notification power capacity is available using the 4009 IDNet NAC Extender Battery backup charging of up to 33 Ah; up to 18 Ah for cabinet mounted batteries and up to 33 Ah batteries for mounting in close-nippled remote battery cabinet General Mechanical: Compact red or platinum cabinet for convenient surface or semi-flush mounting; rated NEMA I and IP30 * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0378 for allowable values and/or conditions concerning material presented in this document. NYC Fire Dept COA #6151. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Sln,pi4* Fire Cont,oI 4007 - 4007ES Hybrid Panel Front View Software Feature Summary: Current and previous panel configuration are both maintained in on-board memory to allow easy selection of desired revision An internal Ethernet service port and an internal serial service port are available for service computer connections to perform configuration updates, downloads and uploads; report downloads, and system software updates (Ethernet port only); the serial port provides the connection for the optional lruelnsight Module An internal USB interface allows a compatible portable memory device (memory stick/thumb drive) to store job revisions, update revised jobs and panel software, and save detailed system reports from the panel without requiring a service computer Optional modules and connections include: Point or Event DACT assembly that is compatible with JP Communicators Up to two additional DNet+ addressable device output loop connections with short circuit fault protection and with 75 additional point capacity each Front mounted 48 LED annunciator with custom label inserts provides 24 Yellow LEDs, 20 Red LEDs, and 4 Red/Green LEDs; LEDs are programmable for up to 24 DC zones of alarm and trouble annunciation or as required for custom annunciation requirements Remote LED annunciator support via RUT (remote unit interface) communications port for use with unshielded, twisted pair wiring (UTP) Alarm relays and auxiliary relays City connections, with or without disconnect switch 4003EC Voice Control Panels 4009 IDNet NAC Extenders to extend NAC capability for power and distance Battery brackets for seismic area protection (see page 2) 4007ES Listings reference: UL 864, Fire Detection and Control (UOJZ) ULC S527, Control Units for Fire Alarm Systems S4007-0001-6 11/2015 S irnrrrriri 4007ES Series Fire Detection and Control Panels provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. The convenient and intuitive color touchscreen provides easy access for typical system response actions and for detailed system review or configuration updates with password control to limit user access. Flexible for new and retrofit applications. Standard conventional 1DCs and addressable fflNet+ communications provide flexibility for both new and retrofit systems. IDC and NAC end-of-line resistor values are selectable to match a wide range of existing initiating device circuits and notification appliance circuits. reTIM"UTIFT M. Convenient Status Information. With the locking door closed, the glass window allows viewing of the display status LEDs. The user interface is a 4.3" diagonal color touchscreen LCD with separate status LEDs as shown below. xti1 FTi 'i .-(.i7T1MJTTJiJ Alarm and Trouble History Logs (up to 1000 entries for each, 2000 total events) are available for viewing from the display or to be downloaded to a service computer or to the USB drive Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring WALKTEST silent or audible system test performs an automatic self-resetting test cycle and supports up to 8 WALKTEST groups Install Mode allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas i rnrn I 'i-i1tt1 Latching front panel assembly swings wrwaru [or convenient internal access Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Modules are power-limited (except as noted, such as relay modules) Battery compartment (bottom) accepts two batteries, up to 18 Ah, to be mounted within the cabinet without interfering with module space; charger capacity is up to 33 Ah; for batteries greater than 18 Ah, refer to page 6 for external battery cabinet details Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet S2081-0019 Locking door with acrylic LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control functions and allows further inquiry by scrolling the display for additional detail. pNtl1 fl .t*Iht. I-k'r.i t1 1tuI(3. Convenient and detailed operator information is easily accessed using a logical, menu-driven touchscreen display with password access control Multiple automatic and manual diagnostics for maintenance reduction Deal lM.4* ii I]_.LYA YA El 11 iJf S4007-0001-6 11/2015 Operator Screen Reference Main Menu Screen provides easy navigation to the function required. Buttons A, B, and C have programmable functions. swriij fnWStuj BUTTON B1JTTON rsEARcH I System Resetj Reset 1 rDiagnosucs 1 B U—ser Ass Lai— mT Levell KM System Alarm Screen identifies active alarms with custom labels displayed, arrows allow navigation through the list FERMIN'SYSTEM 9:04 AM rIrT1flhvM' I t XWFIRM 4!l.1. Menu 1IIl1ll.]k'i System Trouble Screen identifies active troubles with custom labels displayed, arrows allow navigation through the list TROUBLE IN SYSTEM SEP i8,2014 9:OS AM Most Recent 012 M1-4-0 SEP 18, 2014 9:05 AM r t Floor Hallway AT DETECTOR DISABLE TROUBLE First of 2 P34 SEP 18, 2014 9:04 AM I CITY DISCONNECT TROUBLE POINT ABNORMAL Point Information Screen allows review of point details, arrows allow navigation through the information. M1-2 PULL STATION DEVICE ADDRESS: 2-2 TYPE: ADRPUL IDNET2 CARD UNIT NUMBER: B RUI NUMBER: LOCAL ---------------------------------------- PRIMARY STATUS FIRE ALARM CURRENT DEVICE CORRECT DEVICE DEVICE ON-LINE PHYSICAL STATE ABNORMAL RAW STATE ABNORMAL ACTIVE STATE OFF ARMED STATE ARMED ENABLED STATE ENABLED Trouble Log Screen allows review of past troubles with time stamp and point details shown. Jun. 19 2014 -- .-.--'--------.....--,- ]f fofltR133 12:00:30 pm Thu 19-JUN-14 FIRE IDNET ZONE ZONEUST POINT TROUBLE (ENTRY 3d 12:00:30 pm Thu 191UN.14 - PULL STATION 3 PULL STATION NO ANSWER User Access Login Screen controls access to panel operations as determined per panel. ocr Access Level ju.. IL 2014 iI tl ti Enter Passcode S S4007-0001-6 11/2015 S S IDNet+ Addressable Device Control Overview. The 4007ES Hybrid provides an IDNet+ addressable initiating device Signaling Line Circuit (SLC) that supervises wiring connections and the individual device communications status on the SLC. With 2-wire IDNet+ SLCs, initiation, monitoring, and control devices such as manual fire alarm stations, TrueAlarm sensors, control relays, and sprinkler waterfiow switches can communicate their identity and status and receive fire alarm system control. Additional addressable interface modules include circuit isolators, conventional DC zone adapters, and interface to other system circuits such as fans, dampers, and elevator controls. 1110 0 M ZN±rr i -i 1 ri.i'i IF1 Each addressable device on the IDNet+ communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A operation is available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for 1-tapping of the circuits for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. With addressable devices, the location and status of the connected device is monitored, logged, and displayed on the operator interface LCD with each device having its own 40 character custom label for precise identification. Addressable initiating device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. TrueAlarm Addressable Sensor Reference _ TrueAlarm Photo TrueAlarm Photo/Heat Sensor with Base Sensor in CO Base Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read (or downloaded as a report) and compared to the alarm threshold directly in percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, and can be used in LED/Switch modes and custom control. (refer to data sheet S4098-0052 for details) TrueAlarm heat sensors can be selected for fixed temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to HVAC system problems. Readings can selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 40070E5 IDNet+ address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet S4098-0024. L!Jhr.IlI4.-I1iTouIN 1T1lI 'l4'A[.(IYJ Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 10 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and end of life. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. II '1 rI IT ii.i IDNet+ Addressable Channel Capacity. The 4007E5 Hybrid provides an isolated output IDNet+ signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. (250 total requires two 4007-9803 IDNet+ Loop Expansion Modules.) IDNet+ SLC Wiring Specifications Maximum Distance 0 to 125 4000 ft (1219 m); 50 ohms from Control Panel 2500 feet (762 m); 35 ohms per Device Load 126-250 Total Wire Length Allowed With Up to 12,500 ft (3.8 km); "T" Taps for Class B Wiring 0.60 pF Maximum Capacitance Between 1 pF IDNet+ Channels Loading per device 0.8 mA supv., 1 mA alarm; 2 mA per activated device LED Wire Type and Connections Shielded or unshielded, twisted or untwisted wire Connections Terminal blocks for 18 to 12 AWG Compatibility includes: IDNet communicating devices and TrueAlarm sensors including QuickConnect and QuickConnect2 sensors; see data sheet S4090-0011 for additional reference * Some applications may require shielded wiring. Review your system with your local Simplex product supplier. S4007-0001-6 11/2015 Power Supply Output and Zone/Relay Module Details Power Supply Output Details (Continued): Battery Charger is dual rate, temperature compensated, and charges up to 18 Ah sealed lead-acid batteries mounted in the battery compartment, and charges up to 33 Ah batteries mounted in an external cabinet Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and NAC current Low Battery Voltage Cutout is selectable when required (required for ULC listing applications) 2 A Auxiliary Output (AUXISNAC) can be selected either as resettable auxiliary power of 2 A @ 24 VDC, or selected to be a simple NAC (SNAC) for sounder base power, 4-wire detector power, or door holder power Zone/Relay Module Details: Select as IDC or Relay; configure up to 8, Class B IDCs, or up to 4, Class A IDCs; or up to 8, Relay outputs rated 2 A resistive @ 30 VDC (NO. or N.C.); or combinations of 1DCs and Relays; each zone is separately configurable as an IDC or Relay output IDC Support. Each IDC supports up to 30, two-wire devices IDC EOL resistor values are selectable as: 3.3 kn, 2 kç, 2.2 kn, 3.4 kn, 3.9 kn, 4.7 kn, 5.1 kc, 5.6 kn, 6.34/6.8 k9, and 3.6 k9 + 1.1 k9; see instructions for more details NAC end-of-line (IUL) resistor values are selectable as: 10k,3.9kD,4.7k9,5.1 k,5.6kn,or15kO Model* Color Descrption - Supv. Alarm 4007ES Hybrid with 4 conventional 3 A NACs and a 6 A output power supply/battery @009101(BA) Red charger; includes lDNet+ communications for 100 addressable points and 1,4007-9801 Zone/Relay module; Note: Add optional module and other currents separately for battery 145 mA 190 mA 4007-9102(BA) Platinum calculations; base panel current does not subtract from the 6 A power available for optional modules and external loads * Models with (BA) are available assembled in the USA by adding the suffix "BA". Module and Accessories Selection Information Factory Model Description Programming 4007-8810 Factory Programming (select) Options 4007-0831 Custom Labels and Programming (requires 4007-8810) Field Installed Optional Modules (refer to diagram on page 7 for module locations) Model description - Supv. Alarm Eight Point Zone/Relay Module, each point is selectable as an IDC input or Relay output, Class A IDCs 83 mA 351 mA 4007-9801 require 2 points (one out and one return); one module is included as standard, select up to 3 additional; max max current shown is for 8 Class B lDCs with 4 in alarm, detector current is added separately 25 VDC Regulator Module; 2 A maximum output; use to power Zone/Relay modules with 1 module 190 mA 445 mA 290 mA 801 mA 4007-9802 connected to initiating devices requiring nominal 25 VDC voltage; refer to technical with 2 modules 390 mA 1156 mA publication 579-832, 2-Wire Detector Compatibility Chart for application details with 3 modules lDNet+ Loop Expansion Module; provides an additional isolated loop with short circuit isolation to the 4007-9803 existing IDNet+ channel, also provides an additional 75 addressable points to the lDNet+ channel NA NA capacity, maximum of two Panel Mounted 48 LED Status Annunciator Module; provides 24 Yellow LEDs, 20 Red no LEDs on 10 mA 10 mA 1.75 mA per LED, 4007-9805 LEDs, and 4 Red/Green LEDs that are programmable for up to 24 IDC zones of alarm with and trouble annunciation, or as required for custom annunciation requirements LEDs on 105 mA max 4007-9806 SDACT Module for Point or Event Reporting; order 2080-9047 connection cables as required (see cable 30 m A 40 A m details under accessories) 4007-9807 City Circuit Module with Disconnect Switch 20 mA 36 mA 4007-9808 City Circuit Module without Disconnect Switch 20 mA 36 mA 4007-9809 Relay Module; relays for Alarm, Supervisory, and Trouble; rated 2 A resistive @ 32 VDC 15 mA 37 mA continued on next page S4007-0001-6 11/2015 Power Supply Output Details: RUI Communications controls up to 10 remote devices at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class B and T-tapped; selectable as Class B or Class A Compatible RUI remote equipment includes: 4606-9202 and 4606-9205 Color Touchscreen Annunciators (up to 6 total), 4100 Series 24 I/O and LED/Switch modules, 4602 Series LED/Switch and I/O Annunciator modules, including 4602-9101 Status Command Units (SCU), and 4602-9102 Remote Command Units (RCU) lDNet+ SLC Output provides electrically isolated Class B or Class A communication; standard capacity is up to 100 addressable points with expansion for up to 250 points using up to two 4007-9803 IDNet+ Loop Expansion Modules (as described on page 4) 6 A Output Rating. This includes current for: special application notification appliances; IDNet devices; module currents; and auxiliary output current (battery charging, CPU, and power supply current does not subtract from the 6 A); when NACs are controlling Regulated 24 DC Appliances, total NAC current available is 3 A Four on-board Class B/Class A NACs, rated 3 A each for Special Application appliances; selectable for SmartSync horn and strobe control, or strobe synchronization; rated 2 A each for Regulated 24 DC appliances 1] fl S S Module and Accessories Selection Information (Continued) Field Installed Optional Modules Model Description -. - Supv. Alarm 4190-8001° Truelnsight Remote Service Gateway Module and Programming Selection Required 4190-6106 * Selection Truelnsight Remote Service Gateway Module Installation Kit; includes module and 62 mA 73 mA harness; configured for dynamic IP address operation unless ordered with 4190-4016 Truelnsight Remote Service Gateway Module for fixed IP Addressing; optional, select if application will use fixed IP 4190-4016 * address * Refer to data sheet S4100-0063 for additional Truelnsight Service Gateway details Batteries } Model Capa6ity_ 6.2 Ah BatteryMounting Details . 12 V Batteries for cabinet mounting; select one battery model per system standby requirements; order quantity of two; to be wired in series for 24 VDC 2081-9272 2081-9274 10 Ah 2081-9288 12.7 Ah 2081-9275 18 Ah 2081-9287 25 Ah For remote mount in Battery Box 4009-9801 Batteries for remote mounting; see battery cabinet details below 2081-9276 1 33 Ah I For remote mount in Battery Box 4009-9802 Battery Accessories Model Color 1pty_I Dimensions - Description - 4009-9801 Beige For up to 25 Ah 16 V4' W 13 112* H x 5'/4" D batteries 1 External battery cabinet without charger, with locking solid (413mm x 343mm x 146 mm) 4009-9802 Beige For up to 33 Ah 25 3/4" W 20 3/." H 4 ID door and battery harness; for close-nippled mounting to fire I batteries 1(654 mm x 527 mm x 105 mm)alarm control panel cabinet Accessories r Model Description 2080-9047 DACT cable, 14 ft (4.3 m) long, RJ45 plug one end, spade lugs on the other; order one per phone line connection required 2975-9812 Red semi-flush box trim; 1 /l6" (37 mm) wide, four corners and trim pieces for top, bottom, and sides 2975-9813 Platinum semi-flush box trim; 1 /l6" (37 mm) wide, four corners and trim pieces for top, bottom, and sides 2081-9031 Series resistor for WSO, IDCs (NO. water flow and tamper on same circuit, wires after water flow and before tamper) 470 0, 1 W, encapsulated, two 18 AWG leads (0.82mm2), 21/2 Lxi W W 1' H (64 mm x 35 mm x 25 mm) 4081-9002 3.3 kG, 1 Wend-of-line resistor harness for non-addressable NACs 4081-9018 10 kG, 1 Wend-of-line resistor harness for Class B non-addressable initiating zones General Specifications Input Power 120 VAC Input 2 A maximum t 102 to 132 VAC, 50/60 Hz 1 A maximum @ 204 to 264 VAC, 50/60 Hz 240 VAC Input Power Supply Including module currents and auxiliary power outputs; I Output switches to Output Rating 6 A total I battery backup 4007ES Hybrid Power I during mains AC 3 A each for Special Application Appliances ' Supply Output Ratings NAC Ratings I failure or brownout 2 A each for Regulated 24 DC Appliances Auxiliary Power Tap conditions 2 A maximum, 24 VDC nominal (19.5 to 31.1 VDC) Special Application Non-Addressable Simplex horns, strobes, and combination horn/strobes and speaker/strobes Appliances I (contact your Simplex product representative for compatible appliances) Regulated 24 DC Non-Addressable Appliances Power for other UL listed appliances; use associated external synchronization modules where required UL and ULC listed for battery charging of 6.2 Ah up to 33 Ah (batteries larger Battery Charger Battery capacity range than 18 Ah require a remote battery cabinet) Ratings (sealed lead-acid Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Supported file types: JPG, BMP, GIF, and PNG Custom Background Display Details Recommended image type is JPG, recommended image size is 480 x 240, and the file size limit is 100 kb Environmental Operating Temperature 32° to 120°F (0° to 49° C) Up to 93% RH, non-condensing @ 90° F (32° C) maximum Operating Humidity Additional Technical Rtrnce Description Document Description Document Installation Manual 579-1102 Single Page Operator Instructions 579-1109 Zone/Relay Module Installation Manual 579-1103 2-Wire Detector Compatibility Chart 579-832 Detailed Operator's Manual 579-1165 - - 6. S4007-0001-6 11/2015 4007ES Mounting and Module Location Reference -r."srirmw - -. ,..... ... flI,,•jw, • IJII]IITILIItIt;IllllllIlIHlIIlIiillIlIUIIIIIIIIIIIIIIII1TIIEEllhiI -- -__• 1 20-7/16 Side View Reference (519 mm) Finished wall surface (including semi-flush Trim Kit if used) Exposed box for semi-flush mounting 1-3/4 (44 mm) minimum 4-7/16 Deep (112 mm) Module Locations: Primary location for 4007-9801 Zone/Relay Module, or 4190-6106 Truelnsight Remote Service Gateway. Location for additional 4007-9801 Zone/Relay Module, or (as shown) 4007-9802 25 V Regulator Module. 4007-9803 lDNet+ Loop Expansion Modules, maximum of two (two are shown). Power Supply Assembly. Location for additional 4007-9801 Zone/Relay Module. Location for additional 4007-9801 Zone/Relay Module. 4007-9807 or 4007-9808 City Circuit Module, or 4007-9809 Relay Module. Battery location for up to 18 Ah batteries. Note: No conduit entry or wiring in this area, 14-7/8" (378 mm) wide. 4007-9806 SDACT location. CPU and User Interface assembly. Location for optional 4007-9805 LED Module. NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. 7 S4007-0001-6 11/2015 4007ES Hybrid Additional Reference rA (4606)(PIatinum) Color LCD TiiEhscreen Remote Annunciator [LPIEXI .0 4606-9202 (Red) Color LCD Touchscreen Remote Annunciator 4007ES Hybrid with optional 48 LED Annunciator Module (4007-9805) S 4007ES Hybrid Operator View with door open Additional Compatible Equipment and Reference Subject - 4009 IDNet NAC Extender Data Sheet S4009-0002 Subject - - Battery and Battery Cabinet Reference Data Sheet S2081-0006 4003EC Voice Control Panel S4003-0002 Seismic Battery Brackets Reference S2081-0019 4606 Series Color LCD Touchscreen Remote Annunciator S4606-0003 Addressable Device Compatibility, IDNet Communication Sensors and Devices S4090-0011 Graphic I/O Modules j S4100-0005 Serial DACT (SDACT) j S2080-0009 4602 Series SCU/RCU S4602-0001 Truelnsight Remote Service S4100-0063 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NEPA 72 and National Fire Alarm Code are trademarks oft/ic National Fire Protection Association (NFP). %Si pJFX Tyco Fire Protection Products• Westminster, MA 0 144 1-0001 USA S4007-0001-6 11/2015 www.simplex-fire.com 02015 Tyco Fire Protection Products. All rights reserved All specifications and other infonnation s/lawn were current as ofdocument revision dale and are subject to change without notice. . 5SimplEx Listings* Fire Alarm Control Panel Accessories System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger 111Ii4-1 Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover with high reliability dual seal construction UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size Larger batteries, up to 110 Ah, mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers: Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/401OES/4100U Series and 4010 Series panels i 'i riirm S Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. l:cflhiTfl1 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The S preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific batteries. Please refer to data sheet S2081-0019 for details. * Refer to details on page 4 and to the referenced individual product data sheets for agency listing status of battery cabinets and chargers. The batteries detailed in this document meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. contact your local Simplex product supplier for proper battery selection per system requirements. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S2081-0006-21 12/2014 Battery Construction Reference Actual appearance will vary with battery size. Sealed outer cover Vent hole (type varies with battery size) Quick connect or post type terminal Potting material, black for negative, red for positive (polarity is also clearly lit marked with + and -) Pressure relief valve Inner Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids V membrane separator Cell group~T (k Cell case (high impact polystyrene) Battery Size Specifications Battery Model del Capacity @ 20 Hour Width* Depth* I'th Height with Approximate Discharge Rate Terminals Weight* 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) (20811-9274) 10 Ah (153 mm) 4-1/16" (103 mm) 4" (1102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8' (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9(229mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16" (284 mm) 10-1/2" (267 mm) 9" (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) S2081-0006-21 12/2014 I :s.jpj1 .ltI aarr-TIFORTer-M, M. RPM [MM NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series (see legend and notes below) Battery Capacity 4003EC 4004R 4007ES& 4006& 4009 4010 4OIOES 4100E51 4100 &4120 Model 4005 4008 (all models) 4100U (2, 4 or 6-Unit) 2081-9272 6.2 Ah 2081-9274 10 Ah 2081-9288 12.7 Ah 2081-9275 18 Ah Ext Note 3 1 Ext Ext Note 2 1 1 2081-9287 25 Ah Ext Note 3 Ext Ext NA 1 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 1 / Ext rectangular 2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 " square" 2081-9296 50 Ah NA Note 3 NA NA NA - Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. . 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33Ah 50 Ah 110 Ah 2081 -9280 4100ES, 4O1OES, NA NA NA NA NA I 4100U, and 4100+ 2081-9281 multiple f I / / I NA 2081-9282 4009-9801 multiple I if ** NA NA NA NA 4009-9802 multiple / NA I NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 20819279l Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110Ah 4081-9301 4004R and 4010 1 / 1 / 1 NA I 4081-9302 I 4081-9306 4100ES, 4O1OES, NA NA NA NA I I 4081-9308 and 4100U * Batteries smaller than those listed are normally mounted in the product cabinet . ** 25 Ah capacity was effective as of 7/2005. / = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible S2081-0006-21 12/2014 External Battery Cabinet Specification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description - Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4' W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red batteries 4003-9860 Beige Multiple Intended for use with 4003EC systems, for up to 33 Ah 9-1/2" H x 24" W x 9" D batteries (refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 40099801* Beige UL and For up to 25 Ah I External battery cabinet without charger, 16-1/4" W 13-1/2" H x 5-3/4" D FM batteries* I with locking solid door and battery I harness; for close-nippled mounting to (413 mm x 343 mm x 146 mm)* For up to 33 Ah 25-3/4" W 20-3/4" H x 4-1/8" D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions Battery cabinet with charger for the 4010 and 4081-9301 Beige 4004R fire alarm control panel; for up to 50 Ah 120 VAC batteries; with front door 22-1/2" W x16-3/4" H x 8-3/8" D (572 mm x 425 mm x 213 mm) 4081-9302 Red Listings include: UL, ULC, FM, CSFM, and MEA (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model & Listings Color Cabinet Description Compatible Chargers Charger Description Dimensions 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100ES/4100U System Power Series Supplies (SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100ES/4100U Additional SPS 2081-9280 batteries; includes 4100-5113 Listings Red 80A battery fuse, 4100-5125 26-1/2"Wx 12" H 12" D include: UL terminals and 4100-5126 4100E514100U Remote Power (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 Supply (RPS) cables; see data sheet for details 4100-5121 4100-51204100ES/4100U TrueAlert 4100-5122 Addressable Power Supply (TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4I00ES/40I0ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to dasheet S4081-0002) Model Color Input Voltage Description I Dimensions 4081-9306 Red 120 VAC 4081-9308 Red 220/230/240 VAC, multi-tapped 4100-9837 1 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®Sirn plEx Tyco Fire Protection Products • Westminster, MA •01441-000l USA S2081-0006-21 12/2014 0 2014 7).'co Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Battery cabinet with charger for up to 110 Ah batteries; NOTE: Required for ULC listed charging of 110 Ah batteries; Listings include: UL, ULC, FM, CSFM, and MEA (NYC), see data sheet for details 27-7/8" W 13-1/2" H x 14-5/8" D (708 mm x 343 mm x 371 mm) S S S S ®Simplex UL, ULC, CSFM Listed, FM Approved * Or M_ Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET IT addressable communications using a single wire pair Operation that complies with ADA requirements Visible LED indicator that flashes during communications and is on steady when the station has been activated The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4007E5, 4008, 4010, 401OES, 4IOOES, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes IIi4-.lil1tTi1 The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (JAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document Additional listings may be applicable; contact your focal Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet or MAPNET II Communicating Devices Addressable Manual Stations IIiiiII1 LRE© iIe OP KEY TED ONLY WMP IN D nt rat ie Activation of the 4099-9004 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station 4099-9021. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break- rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by - unlocking the station housing to activate the alarm switch. S S S S4099-0005 10/2014 AddressableManual Stations, Red Housing with White Letters and White Pull Lever Model Description - Housing_ Pull Lever - Listings 1 UL, ULC, FM, CSFM 4099-9004 Single Action, English FIRE ALARM PULL DOWN 4099-9004GB Single Action, Bilingual English and French FEU FIRE TIREZ PULL ULC 4099-9004CF Single Action, French ALARME FEU ABAISSEZ 4099-9004P0 Single Action, Portuguese FOGO ALARME PUXE 4099-9004SP Single Action, Spanish ALARMA FUEGO JALE UL FM 4099-9005 Double Action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM 4099-9005P0 Double Action, Breakglass operation, Portuguese FOGO ALARME PUXE 4099-9005SP Double Action, Breakglass operation, Spanish ALARMA FUEGO JALE UL FM 4099-9006 Double Action, Push operation, English FIRE ALARM PUSH PULL DOWN UL, ULC, FM, CSFM 4099-9006P0 Double Action, Push operation, Portuguese FOGO ALARME EMPURRE PUXE FM UL 4099-90065P Double Action, Push operation, Spanish ALARMA FUEGO EMPUJE JALE 4099-9021 Single Action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Accessories (refer to pages 3 and 4 for details) [Model Description Model Description - Replacement breakglass 2975-9022 Cast aluminum surface mount box, red 2099-9803 2975-9178 Surface mount steel box, red 2099-9804 Replacement break-rod 2099-9813 Semi-flush trim plate for double gang switch 2099-9828 Institutional cover kit for field installation on 4099-9004; box, red Note: Covers LED indicator 2099-9819 Flush mount adapter kit, black 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9820 Flush mount adapter kit, beige 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions 579-1007 for details Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color, White with red raised lettering Housing Dimensions 5" H x 3W Wx 1" D (127 mm x 95 mm x 25 mm) 4" Square Box Mount 4(102mm) square box, 2 1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) o (o\/' I Mn,,nf fl,,I, or with Single Gang Box Mount Single gang box, 2 1/2" deep (64 mm), RACO #500 or equal (supplied by others) C 1/16" (2 mm) J maximum extension DO NOT RECESS 4" Square box 0 with cover plate S LED Indicator FIRE ][ALARM I PULL DOWN [SimplEx] Station side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 or equal (supplied by others) I Single gang I Wall surface 1__1r box outline Semi-Flush Mount Side View 2 S4099-0005 10/2014 Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 5-3/16" H x 4" W 2-3/16' D (132 mm x 102 mm x 56 mm) (ordered separately) \ Knockouts located top and bottom 2975-9022 Cast Box 5" H 3-7/8" W 2-3/16" D (127 mm x 98 mm x 56 mm) (ordered separately). Oil 10 FIRE PULL DOWN Access for 3/4" threaded conduit located top and bottom (127 mm) [Osimpiex] 1" (25.4 mm) 3-3/4" (95 mm) 4099 Series Addressable Manual Station Surface Mount Side View with Internal Detail Application Reference Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all 11/4" applicable local codes for complete Field wiring (32 mm) Simplex 2975-9178 box requirements for manual stations. The (shown for reference) (shown for reference) - - following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed Address setting under in the protected area such that they resealable label (accessible / are unobstructed and readily with cover open) -i a accessible. 2-5/8" / (67 mm) Mounting shall be with the operable part not less than 42 in Station cover / (1.07 m) and not more than 48 in hinges open for (1.22 m) above floor level. installation access At least one station shall be Switch wiring provided on each floor. Additional N (prewired) stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. - - - When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0005 10/2014 Addressable Manual Station, Additional Mounting Information For retrofit and new installations, I I I additional compatible mounting I Wiremold boxes and the required adapter plates 11 receptacle box are shown in the illustration to the 2099-9814 Surface trim II I model V5744-2 for Wiremold box II I I I I I II I I I (supplied by right. 5-1/8" H x 5"W II I I others) (130 mm x 127 mm) Two gang switch box, each 3" H x 2" W x 2-3/4" D I I]IAJ (76mmx51 mmx70mm) (supplied by others) Addressable 1L!L D2J 1=3 C:Ddl station 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W -i (152 mm x 114 mm) Flush mount adapter kit S 2099-9819, Black 2099-9820, Beige Box must be recessed into wall 1" to 1-1/8" (25.4mm to 29mm) 8" [1E1\ (203 mm) 6' (152 mm) 0 :0 0 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Hole cutout must be a minimum of 6" H by 5" W (152 mm by 127 mm) _ _ Wall 4-3/4" (121 mm) surface 6-3/4" (171 mm) Front View Side View TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4099-0005 10/2014 www.simplex-fire.com 0 2014 'l)co Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject /a change without notice. S SimpIEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors - Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories I 11' I(*1 TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and IJLC-5529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMIl compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272.0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. '7TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-22 10/2016 TrueAlarm Sensor Bases and Accessories 11*1 Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test (4 ajr base) 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) :s] 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A@ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) ALARM Simplex & I Dsrintinn TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. lvuouflLurlg rcetererice Electrical Box Requirements: (boxes are by others) Without rg Ua in the box: 4" octagonal or 4" square, 1-1/2 deep; single gang, 2" deep With relaV in the box: 4" octagonal 0r4" square, 1-1/2" deep, with 1-1/2 extension ring 4" (102 mm) Square Box 4' (102 mm) Octagonal Box Surface mount reference-. W-7 1 c L1H 1-1/2 (38 mm) I minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4(6.4mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) ze '"'-1/2" X 3.75 in3) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8 X 1-114"X 11/32" (1 in3 )(60.4 mm X 31.8 mm X 8.6 mm) - NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. l 6-3/8" (162 mm) t 4098-9832 Adapter Plate, required for 1/4' mounting to surface mounted boxes (6.4 mm) and 4" flush boy I' 4-7/8 (124 mm) 15/16" (24 mm) o TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S S S4098-0019-22 10/2016 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.10 C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 1550 F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to spec/lc panels for availability. TI 2-3/8 (60 mm) 4098-9733 Heat Sensor with Base TrueAlarm Sensors • Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135°F 60ftx60ft 20ftx20ft(6.lm) for fixed (57.2' C) (18.3 m) temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed 155' F 40 ft X t 40 temperature with either rate-of-rise (68° C) (12.2 m) selection; RTI = Ultra Fast Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response Built-in insect screens I:1IJ iTT1 TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode 01 receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for I WARNING: In most fires, hazardous levels of smoke I optimum response to smoke from any direction. Due to its and toxic gas can build up before a heat detection photoelectric operation, air velocity is not normally a device would initiate an alarm. In cases where Life I factor, except for impact on area smoke flow. I Safety is a factor, the use of smoke detection is highly recommended. I f -I 4-7/8' (124 mm) LED status indicator 2-1/8' (54 mm) 4098-9714 Photoelectric Sensor with Base I Ann1katinn Rfrcnr Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. fl S4098-0019-22 10/2016 TrueAlarm Analog Sensing Product Selection Chart TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Anolication Manual 574-709 and Installation Instructions 574-707 for additional information) L 'Mdel*_-- cF ti5 i catiiiit Ti (O98!792) White Standard Sensor Base No options 4" octagonal or 4" square box, 1-1/2" mm. depth; or single 4098-9776 Black gang box, 2" mm. depth 4098-9789 White Sensor Base with connections Sensor for Remote LED Alarm Indicator 2098-9808 Remote Alarm Indicator or " octagonal or 4" square box 4098-9789 IND or Unsupervised Relay 4098-9822 Unsupervised Relay Note: Box depth requirements - 4098-9775 Black depend on total wire count and wire size, refer to accessories 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 40989791** White Base with connections for LED list below for reference. Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay with the 2120 CDT 2098-9808 Remote Alarm Indicator or 40989780** White Base with connections for LED Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay TrueAlarm Sensors _______ MI M&iel - trition_ CompatibiIity_ ______ M&iting Requirements (4098!97.14 White 4098-9714 IND I Photoelectric Smoke Sensor Bases 4098-9775, 4098-9776, 4098- 4098-9774 Black 9792, 4098-9789, 4098-9791, and Refer to base requirements r4098:9733) White 4098-9780 4098-9778 Black Heat Sensor TrueAlarm Sensor/Base Accessories LMdec: b iji T_T Compatibility------ 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal or electrical box --- 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal box, 4098-9860 Supervised Relay, mounts remote or in base For use with 4098-9780 base electrical box 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789, 4098-9791, and Single gang box, 1-1/2" minimum depth gang stainless steel plate 4098-9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, and 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box 4098-9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush mounted 4098-9832 Adapter Plate 4098-9791, and 4098-9780 4" square box and for surface mounted 4' octagonal box * Note: Model numbers ending in IND are assembled in India. General Ooeratina Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32" to 100" F (0" to 38" C) Operating Temperature with 4098-9733 Heat Sensor Range with 4098-9714 Smoke Sensor 32" to 122" F (0" to 50" C) 15° to 122" F (-9' to 50" C) Storage Temperature Range 0" F to 140" F (-18" C to 60" C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/mm (0-1220 m/min) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 j.jA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO, SJMPLEA and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and Nalio,,al Fire Alarm and Signaling Code are trademarks of/he Notional Fire Protection Association (7'IFPA). B®S mi p1 EX Tyco Fire Protection Products • Westminster, MA - 01441-0001 USA S4098-0019-22 10/2016 ' 2016 Tyco Fire Protection Products. All rights reserved All spec/flea/ions and other information shown were current as ofdocument revision date ant/ore subject to change without notice. fl S n 0 B®Si m pIEX TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control 11(1114-i Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by JDNet1MAPNET II communications ModeIO98-9756:) Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: . UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Duct Sensor Housing, Front and Bottom View II 0 iiII II II ii II II II II 2098-9808 (2098-980 Remote Status/Alarm Indicator and Test Station dtittie Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. III .F1liiI IIm1.1LIJ.NtltiTi1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. S4098-0030-10 11/2014 IflT.1 Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) IJ iii1 ñq TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. I rnnf.IimwJ7irrJij Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. . Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override Duct Smoke Sensor Housing with Photoelectric Sensor* . F Model Description Cciin'patibility___________________________________ Basic Duct Sensor Housing; operating power is supplied by 4007ES, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4098-9755 either lDNet or MAPNET II communications (no relay 4100E, and 4120. Also 2120 CDT if configured for output) MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required r Model Description 2098-9808 Red LED status indicator on single-gang stainless steel plate Test Station with keyswitch and red LED status indicator, on 2098-9806 single-gang stainless steel plate; (turning switch to "TEST" initiates alarm for system testing) Compatibility Mounting Use single gang box, 4098-9755 3" Hx2"Wx2" D 4098-9756 I (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description - . Compilit_I Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; (1 m) of device being wiring is 18 AWG (0.82 mm2 ) color coded wire leads connect up to 15 controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kc, 1/2 W; (ref. 733-894); 4098-9756 I At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-97,14 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width Tube Required ' Suggested Cut Length (305 mm) , 4098-9854 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (11168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 4098-9858 3 in" (76 mm) longer than duct width 'sIsI:,I*I,5[,ffP.Jfl S NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. —11-3/8(289 mm)— Exhaust tube access hole 1 (171 mm) Sampling tube access hole 4098-9714 Smoke sensor, in special interface base (: Metal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole 900000 Dr . II •T1L'M 0 GOOD a GOD GO Yellow LED, relay 160 control trouble (ndicator (4098-9756 only) Red sensor 0E status EJ of duct screws Li ransparent coven 3-3/8 (86 mm) 13/16" / (21 mm) ' usttub_..j upplied Test ports (2) provided ] for measuring airflow and for aerosol injection [Sampling tube, ordered 1 separately per duct width reference outline NOTE: Orientation shown is for reference sensor area] only, refer to General Location Notes and End View illustration below for alternate mountinq reference. 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 Only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1-3/16" (30 mm) 1-1/2" 13/16" location (38 mm)_ 21 mm) 0 18" Round duct outline (minimum diameter) Sampling tube, keyed for proper hole alignment with hole~acin, nto airflow(template isprovided forpropertube installat 0 ousing is shown as position 2 per note 2 below.) 0 ' 0 Duct 1 housingj I Exhaust tube] 8" Square duct outline] 1 0 lz'-___7_- ----------- DO NOT MOUNT ON BOTTOM OF DUCT /\ General Location Notes: Testing performed under the auspices of the Fire Detection Institute (FDl) recommended when sampling tubes are not located vertically, that they be positioned horizontally in the upper half of the duct to account for possible stratification. Three duct side mounting options are available as shown below. Mount housing at 90° to airflow for all orientations. Arrows indicate allowed airflow directions. U © U I 3 S4098-0030-10 11/2014 191M ]il'(i ,-Exhaust Damper 4/' Se Exhaust --LIJ II Do not locate sensor here Return air damper Freshair —'- Ii Ii 7W Do not locate Filter bank sensor here Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NE/VIA Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-776. Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. Duct air velocity rating is 300 to 4000 ft/min (91 to 1220 m/min). Pressure differential between intake and exhaust tubes is required to be between 0.0 15 to 1.55 inches of water (0.381 to 39.37 mm). Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. OK Return Air -*- Supply Air Sensor OK General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 1000 F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color and Material Black ABS base with clear polycarbonate cover Sampling and Exhaust Tube Material Black CPVC, custom extrusion; sampling tubes are pre-drilled Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; I provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current 15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kQ, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC & 120 VAC; 250 l.LA © 5 VDC S Location Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device being controlled per NFPA 72 7'YCO, SIMPLEX, and the product names listed in this material are marks and'or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). 115 i rn P I EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4098-0030-10 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reset-red All specifications and other information shown were current as of document revision date and are subject to change without notice. Usk" 1001 t00tttt g 409E, 0-900, 900091! ott lOt ISIR 111311 DATE 000: 90900))Supervised lAM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) I fltsrintinn Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. a BSim plEx Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet and MAPNET II Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (lAMs) I1iui*i IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from lAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007ES, 4008, 4010, 401OES, and 4100ES fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: - Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 . * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4090-0001-12 8/2016 L!J 'I tT1 ['iii i*iiIUITiTR tsjriiTMLM ItT1 Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only, these initiates an alarm or other response as programmed at the JAMs can provide quad-state sensing of normal, open fire alarm control panel. An open in the monitored circuit circuit, short circuit, and current limited conditions. wiring will cause a trouble to be reported. (Program type is "T-sense.") With the proper end-of-line Panel Selections. Selections can be made at the control and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a determined and communicated by a single addressable rate-of-rise heat detector, or to track the device contact point. status (not available with the 2120 CDT). PIT r2r.r. rrri rirm Model Description -- 409O9O0iJ Supervised [AM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kc, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kc), 1/2W Use for current limited monitoring applications 4081-9005 733-984 1.8 kQ, 1/2W Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2 Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9051 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference IDNet Communications per channel, MAPNET II or 2500 ft (762 m) maximum from fire alarm control T-Taps) 10,000 ft (3048 m) maximum total wiring distance (including Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-12 8/2016 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference 1 LED viewing port * Single gang electrical box 2-1/2 (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-1/4" (108 mm) (5 _ Light pipe for © LED viewing (114 mm) [BEFORE SERVICING I DISCONNECT POR IDSCONNECT POER 1 © © CD 2-1/2" (64 mm) 4090-9806, Trim plate for semi-flush mounted box _________ 2-13/16" __ (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-12 8/2016 4090-9051 Mounting Information Single gang electrical box 2-1/2 (64mm) minimum depth by others) Single gang blank cover plate and mounting screws (supplied by others) ii Sirn pIEX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA s4090-0001-12 8/2016 www.simplex-fire.com 2016 Two Fire Proleclion Producer Al! rig/its reserved. All specifications and other information shown were current as ofdocument revision dale and are subjeci to change without notice. 0 9 B®SimpIEx UL, ULC, CSFM Listed; FM Approved, MEA (NYC) Acceptance* ItuI4.1 Individual Addressable Relay Module (Relay lAM): IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008, 4010, 40I0ES, 4100ES, and 4100U A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Relay is set to OFF on initial power up and upon loss of IDNet communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11/16" l/ (119 mm) square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 Iii1llTi1 IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. I I;rt1 -W(Td—el —1 Description C4090903 jRelay lAM Optional Adapter and Trim Plates [di Descripon j 4090-9813 Adapter plate to fit 11/ (119 mm) square ~ electrical box 4090-9801 For semi-flush I Trim Plate, galvanized mounted box I steel, with LED viewing For surface window; includes 4090-9802 mounted box I mounting screws * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35.93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9002 Relay lAM 4'0909002)lDNet Relay IAM Package (shown approximately 1/2 size) Specifications IDNet communications, 1 address per Communications device Relay lAM Power Supplied by IDNet communications Contact Ratings* (not rated for incandescent switching) Type Form C, SPDT 2 A @ 24 VDC, resistive from listed Power-Limited fire alarm 1 A @ 24 VDC, inductive supply Nonpower-Limited 0.5 A © 120 VAC, resistive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to the installation instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 14" H x 4 1/s" W x 1 %" D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Installation 574-184 Instructions S4090-0002-10 11/2014 I. 'S S 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9002 Relay IAM Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Address setting under resealable label - - - S I iriiri'mrnii rn1.idiIr1 CD Mounting Reference, Double Gang Blank Cover Plate LUO POR I 7 Light pipe for LE 16" E BEFORE SERCING j (116 mm) I viewing [ DISCNR1 BEFE SERCING 4-5/16" (109 mm) -9/16" (116 mm) -5/16" (109 mm)- 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®S i in p1 EX Tyco Fire Protection Products Westminster, MA 01441-0001 USA S4090-0002-10 11/2014 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. . B®SimpIEx UL, CSFM Listed; MEA (NYC) Acceptance* System Accessories Fire Alarm Control Relays, Track Mount and Encapsulated; Model 4098-9843 and 2088 Series UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts LED indicates relay module status Cover provide status LED viewing ports Multiple coil voltage inputs, diode polarized for DC Modules are track mounted with snap-apart feature design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions: 2088-9021 (PAM-1) Provides diode polarized multiple input voltage ability and LED indication 4098-9843 (PAM-SD) Provides a diode polarized 24 VDC coil with in/out wiring -IfflDescriptic These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four-module assembly and used independently if desired. Track Mount Relays, see page 2 for dimensions Coil Voltage 18-35 VACNDC, 120, or 230 VAC Coil Current SPDT models = 18 mA DPDT models = 40 mA Terminal Blocks Up to 14 AWG (2.08 mm2 ) Contact Ratings 10A@ 120 VAC N.C. rated 1/6 HP, N.C. rated 1/8 HP 7A@28VDC and @23OVAC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 85% RH Non-condensing l., i: i:u iii! U! :. C, 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021 PAW and 4098-9843(PAM-SD)) .1:11111 1W. 11M W.MV1010111111111=0 Encapsulated Relays, see page 2 for dimensions Connections 118 AWG (0.82 mm2 ) color-coded wire leads Relay 2088-9021 Contact Ratings 10 A@ 120 VAC, resistive Voltage Coil Ratings Current 18-35 VAC/VDC, 120, or 240 VAC 15 mA @ 24 VACIVDC, &@ 120 or 230 VAC Relay4098-9 Coil Ratings 18-32 VDC input, polarized, 15 mA @ 24 VDC Contact Ratings 7 A at 0.35 p.f @ 28 VDC & 120 VAC 250 pA @ 5 VDC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 100% RH, condensing * Listings are under Apollo America Inc. per model numbers shown on page 2. See CSFM Listing 7300-1004:0101 for allowable values and/or conditions concerning material presented in this document. S2088-0010-10 11/2014 (18-35) VDC Coil voltage (note polarity (18-35) VAC for DC) 120 VAC 230 VAC (18-35) VDC Coil voltage (note polarity (18-35) VAC for DC) 120 VAC 230 VAC Relay Selection Chart Module Reference Model Relay Packaging Dimensions Positions Number Number Type 2088-9007 MR101/T SPDT 3-1/4" H x 2-1/8" W 1-1/2" D Track mount, without cover (83 mm x 54 mm x 38 mm) 2088-9009 MR-2011T DPDT One 2088-9008 MR101/C SPDT 5-1/8" H x 3-1/8" W x 2-1/2" D Track mount with cover (131 mm x 79 mm x 64 mm) 2088-9010 MR-201/C DPDT 2088-9017 MR-104/T SPDT 3-1/4" H x 8-1/2" W 1-1/2" D Track mount, without cover (83 mm x 216 mm x 38 mm) 2088-9019 MR-204/T DPDT Four 2088-9018 MR104/C SPDT 5-1/8" H x 9-1/2" W 2-1/2" D Track mount with cover (131 mm x 241 mm x 64 mm) 2088-9020 MR-204/C DPDT Encapsulated, multi-voltage coil 1-1/2" H x 1" W 7/8" D 2088-9021 PAM-1 2') color coded 18 AWG (0.82 mm wire (38 mm x 25.4 mm x 22 mm) ____________ ____________ leads, with coil status LED NA SPDT 4098-9843 PAM-SD Encapsulated, 24 VDC coil, color coded 18 AWG (0.82 mm2 ) wire leads (no 1-1/2" H x i-3/16"Wx 13/16" D (38 mm x 30 mm x 21 mm) LED) I Track Mount Relay Wiring Reference SPDT contacts rated 10 A @ 120 VAC, resistive DPDT contacts rated 10A@ 120 VAC, resistive NC C NO® 0 18/24 115 230 Relay energized LED 0 18/24 115 230 S Terminal strip connections Terminal strip connections SPDT models DPDT models S TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. G.Simplex Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S2088-0010-10 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S 0 B®Si m plEx TrueAlert Multi-Candela Notification Appliances UL, UL C, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSync Operation Compatible S Ii1!Ii4.1 Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: Simplexo fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. (Wall Mount Strobes) k~I . IR E PAW WA (Ceiling Mount Strobes) Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. )EJ IF1IEF1ILV eIf(LIL During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. I [*1 [s1•( EItx]iI.( Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001-5 11/2014 S M11411U61111 PTI Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized - flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. SmartSync Two-Wire Control, I Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). 1117111.lul(.(*-I SmartSync two-wire control is available from: 4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Product Selection Multi-Candela Visible Notification Appliances (Strobes) L_Model Mounting HousijCoIor "FIRE" Lettering Description ç49Q691o) Red White Wall Multi-candela strobe with intensity selectable as: 4906-9103 White Red 15, 30, 75, 01110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two-wire control compatible 9069:1 o) White Red Wall Mount Strobe Adapters Model Description , Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-114"-Wx 1-5/8" D (136 mm x 133 mm x 41 mm) 4905-9940 white deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter [ Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) L Model Description . Dimensions - 1 4905-9914 Class B I Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm 2) wire leads, rated for 2 A NAC, 1-3/8" 2-7/16" x 13/16" 4905-9922 Class A requires 5 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering White cover with red "FIRE" lettering I For Wall mount strobes 5-1/8" H x 5" W 1-1/2" D (130 mm x 127 mm x 38 mm) 4905-9993 6-1/16" H x 6-1/16" W 3-1/8" D 49059961* Wall mount Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 6-1/8" x 4-3/8" x 2-7/8" deep 49059926* Ceiling mount (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc. S4906-0001-5 11/2014 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others 1 0999 If WiringI'terminals Jl :101 1 I Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting S S IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly box outline above bottom of boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd H Removable cover Strobe intensity (tool required) Viewing slot 3 4 S4906-0001-5 11/2014 S Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V57445) 2-1/4 (57 mm) deep, supplied by others Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for 0 0 O( surface mount with handy box unless using the 4905-9926 wire guard mount strobe Optional 4905-9926 wire guard with mounting plate - Strobe intensity viewing slot Intensity selection plug, - accessible only from rear of lens housin factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 45 [I: 'lh—lh---lI---lt---tl 0 11 11 -11 fl a ____ ° / - / 4905-9931 Adapter Plate FUFE 0 - 4905-9961 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NF PA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®Si rn plEx Tyco Fire Protection Products Westminster, MA •01441-0001 USA S4906-0001-5 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. SimpIEx TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable I lii I(*1 Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) UL listed to Standard 464 I .J4-r71 Multi-Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. FI rrnu'i-n rtri During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125.0026:317 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4906-0002-6 11/2014 rrrtrii-ri M., Proper Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). OTT401 I.iT1 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these ANs are synchronized by the controlling SmartSync operation NAC. f1iVflT am 'I SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." 4006, 4007ES Hybrid, 4008, 4010, 40I0ES, 4I00ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela ANs Model 4906-9127 (4906-9129) Mounting Wall Housing Color Red "FIRE" Lettering White White Red 4906-9128 49O6 9130) Ceiling Red White White Red Description Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire control Dimensions 5-3/8" H x 5-1/4" W x 1-5/8" D (136 mm 133 mmx4l mm) depth with strobe = 4-3/8" (111 mm) 8-5/16" x 5-3/4" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) 1-3/4" Diameter (44.5 mm) with 0.31" (8 mm) sound opening Dimensions 4" x 4-1/8" x 1-1/4" D (102mm x 105mm x 32mm) Dimensions 5-1/8" H x 5" W x 1-1 /2" D (130 mm x 127 mm x 38 mm) Dimensions 6-1/16" H x 6-1/16" W x 3-1/8" D (154 mm x 154 mm x 79 mm) 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 9" x 7" (229 mm x 178 mm) 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) Wall Mount A/V Accessories Model I Description 4905-9937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm) deep 4905-9940 White surface mounted boxes 49059931 I Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for I retrofit, may be mounted vertical or horizontal) 2975-9145 1 Red Mounting Box, requires Adapter Plate 4905-9931 Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA NOTE: After Sound Damper installation, measure sound level to ensure compliance with applicable code requirements SmartSync Control Module Model Description 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" (102 mm) sauare box: refer to data sheet S4905-0003 for details Replacement Covers for Wall Mount A/Vs Model Description 4905-9994 Red cover with white "FIRE" lettering 4905-9995 White cover with red "FIRE" letterina Wire Guards and Ceiling Mount AN Adapter Model I Description - - 4905996 Wall mount red wire guard with mounting plate, compatible with semi-flush 1* or surface mounted boxes 49059927* I I Red Wire Guard for mounting to flush mounted electrical box 49059928* I Ceiling I Red Adapter Plate, required to mount guard to surface I Mount I mounted electrical box 4905-9915 I I White I Surface Mount Adapter Box Extension, use to cover 4905-9916 Red I 1-1/2" deep surface mounted boxes * UL listed by Space Age Electronics Inc. S4906-0002-6 11/2014 2 AN Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 DC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage Ratings Sound Type (see Note 2) 16 VDC 24 VDC 33 VDC Steady Coded Steady Coded Steady Coded @ lOft (3 m) UL 464 Reverberant Chamber (see Note 2) Anechoic Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x SW x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mou nt Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 Cd 30 Cd 75 Cd 110 Cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 103 mA 196 mA 253 mA I 50 mA 77 mA - 147 mA 190 mA I Housing Dimensions (with lens) 4-3/4 L" x 6-7/8W x 2-5/8" D (121 mm x 175 mm x 67 mm) CeilingStrobe Maximum RMS Current Rating per Setting (see Note 3 below) 15 Cd 30 Cd 75 Cd 110 Cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA 57 mA 88 mA 167 mA 213 mA I NOTES: 1. "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed Sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting S Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Optional 4905-9838 Sound Damper, field attached to attenuate sound 5 to 6 dBA Wiring access hole Wiring terminals for SmartSync operation çTh (Th c Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r —Electrical above bottom r box outline of compatible \ ri boxes 1 --7 NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor I Mounting Holes: 4" square (4) Single gang (2) Double gang (3) en Strobe intensity ' Removable Cover (tool required) viewing slot S4906-0002-6 11/2014 Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, surface mounted box 1-1/2" (38 mm) minimum depth C Ceiling reference, flush mounted bo: Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side Optional 4905-9927 Red Wire Guard ------------------------------------ Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 0 4905-9931 Adapter Plate 45 Box 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4"(102 mm) square I box profile, 1-1/2' (38 mm) deep Optional 4905-9961 Wire Guard AN ==-7 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (XT-PA). 93,Simpl,Ex Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4906-0002-6 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. 0 0 Simplex UL, ULC, CSFM Listed; FM Approved* TrueAlert Multi-Candela Notification Appliances Multi-Candela, High Intensity (non-addressable) Strobe (V/O) and Horn/Strobe (NV) S I(JI(4i 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135, 177, or 185 candela; visible selection jumper is secured behind strobe housing Regulated circuit design ensures consistent flash output and provides controlled inrush current Control is compatible with Simplex® SmartSync two-wire operation Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings available in red or white with clear lens Models are available for wall or ceiling mount Strobe operation is UL listed to Standard 1971 Appliances with audible notification (horn): Low current electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) Horn operation is UL listed to Standard 464 Strobes provide synchronized flash for use with: Simplex fire alarm control panels and NAC Extenders when selected to provide strobe synchronization or SmartSync two-wire control Separate strobe Synchronization Modules or SmartSync Control Modules (SCMs) that convert conventional NAC inputs to a Smartsync output SmartSync two-wire operation provides: Horns controlled separately from strobes on the same two-wire circuit, activated as Temporal pattern, March Time pattern (at 60 BPM), or on continuously Wall mount appliance features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color AN models have an available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs E[I1R1E - II! yvalland Ceiling Mount High intensity Strobes (top) andHorn/Strobes (bottom) Dsrintit Convenient Selection and Installation. TrueAlert multi-candela high intensity appliances provide convenient installation to standard electrical boxes. They are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall Mount. Housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling Mount. Strobe appliances install using standard single gang electrical boxes. Horn/strobe appliances install using standard 4" electrical boxes. Color choice is determined by model number. 1( ['1 I1I1I tl.l I I II'14 [i'l ! IS] i• During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. 71 YWTT1 Fr rTITT1 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). This product has been approved by the California State Fire Marshal (CSFM) pursuant to S Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125.0026:333 for allowable values and/or conditions concerning material presented in this document Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Ustings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4906-0011-3 11/2014 S t Mr, VS OWN MOT, I SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." I.- i SmartSync two-wire control is available from: 4006, 4007ES Hybrid, 4008, 4010, 401OES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 lDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) I Product Selection Strobe (V/O) Model Housing Lettering Mounting Description 4906-9109 Red White - 4906-9111 White Red Wall Multi-candela strobe with intensity selectable as: 135, 177, or 185 candela; synchronized flash rate; SmartSync two-wire control 4906-9110 Red White Ceiling compatible 4906-9112 White Red Horn/Strobe (AN) [ Model Housing. Lettering Mounting Description - 4906-9139 Red White C4906;9141 White Red Wall Horn and multi-candela strobe with intensity selectable as: 135, 177, or 185 candela; synchronized flash rate; operates with SmartSync two- 4906-9140 Red White Ceiling wire control 4906-9142 White Red Wall Mount Common Accessories - I Dimensions Mod& Description - i 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W 1-5/8" D I (136 mm x 133 mm x 41 mm) 4905-9940 White surface mounted boxes depth w/strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) AN only; Optional Sound Damper; package of 20; field installed adhesive 4905-9838 backed horn output attenuator; reduces output 5 to 6 dBA NOTE: After Sound Damper installation, measure sound level to ensure compliance with applicable code requirements LLQ Model AN Model Description 4905-9992 4905-9994 Red Wall Mount Replacement cover with white "FIRE" lettering 4905-9993 4905-9995 White Wall Mount Reolacement cover with red "FIRE" lettering 8-5/16" x 5-3/4" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 1-3/4" Diameter (44.5 mm) with 0.31" (8 mm) sound opening Dimensions 5-1/8" H x 5" W 1-1/2" D (130 mm x 127 mm x 38 mm) Synchronization Module Reference (refer to data sheet S4905-0003 for additional information) L Model Description - - Dimensions- 4905-9914 Class B I Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 10 mA for power; for use with V/O only when not supplied from panel 1-3/8" x 2-7/16" x 13/16" (35 mm x 62 mm x 20 mm) 4905-9922 Class A 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Wire Guards and Adapters (see page 4 for reference diagrams) L Model Description . . . AN or V/O Wall Mount Red Wire Guard with Mounting Plate, for semi-flush or DimIons 4905-9961 * 6-1/16" H x 6-1/16" W x 3-1/8" D surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9926 V/O Ceiling Mount Red Wire Guard with Mounting Plate, for semi-flush or 6-1/8" x 4-3/8" x 2-7/8" deep surface mounted boxes (156 mmxlii mmx73mm) 49059927* AN Ceiling Mount Red Wire Guard for mounting to flush mounted electrical 8-1/2" x 6-1/8" x 3" box (216 mm x 156 mm x 76 mm) 49059928* Red Adapter Plate, required to mount 4905-9927 guard to surface mounted x 7" (229 mm x 178 mm) electrical box 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to handy 4-7/8" x 3-1/8" x 0.060" D box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) 4905-9915 White Ceiling Mount AN Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. PAI S4906-0011-3 11/2014 I Specifications (refer to Instructions 579-859 for additional information) UL Listed Rating Rated Voltage Range ULC Listed Rating Regulated 24 DC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Screw Terminal Connections 18 AWG to 12 AWG (0.82 mm' to 3.31 mm2); two wires per terminal for in/out wiring A/V and V/O Wall Mount 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Dimensions (with lens) VIO Ceiling Mount 4-3/4" Lx 2-5/16" W 2-5/8" D (121 mm x 75 mm x 67 mm) AN Ceiling Mount 4-3/4 Lx 6-7/8" W 2-5/8" D (121 mm x 175 mm x 67 mm) Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate AN Horn Ratings, UL 464 Reverberant dBA @ 10 ft (3 m); at Chamber 24 VDC (see Note 2) Anechoic Chamber Angular Dispersion Steady Sound Output Coded Sound Output (see Note 2) Wall Mount Ceiling Mount Wall Mount Ceiling Mount 86 dBA 87 dBA 82 dBA 83 dBA 92 dBA 93 dBA 92 dBA 93 dBA Per ULC S525; -3 dB at 45° off-axis for both wall and ceiling mount models Maximum RMS Current Rating per Wall Strobe Setting (see Note 3 below) Mount Visible Only (VIO) AudibleNisible_(A!V) 135 Cd 177 Cd 185 Cd 135 Cd 177 Cd 185 Cd 314 mA 390 mA 409 mA 333 mA 418 mA 433 mA Reference RMS Currents - 18 VDC at other voltages 24 VDC 279 mA 347 mA 364 mA 296 mA 372 mA 385 mA 209 mA 260 mA 273 mA 222 mA 279 mA 289 mA Maximum RMS Current Rating per Ceiling Strobe Setting (see Note 3 below) Mount Visible Only (VIO) Audible/Visible_(A/V) 135 Cd 177 Cd 185 Cd 135 Cd 177 Cd 185 Cd 356 mA 431 mA 447 mA 389 mA 456 mA 463 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 316 mA 383 mA 397 mA 346 mA 405 mA 412 mA 237 mA 287 mA 298 mA 259 mA 304 mA 309 mA NOTES: "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal pattern or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) I Ffl lT 1wi iD( 1rnt,(Z.1flm! [I Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep by others NV housing is shown for reference; optional 4905-9838 Sound Damper (shown) attenuates sound 5 to 6 dBA, field installed Wring access hole 0 0 Wiring terminals a 0 . \\ Mounting Holes: 'p \ 4" square (4) Single gang (2) Double gang (3) 'Transparent housing and lens assembly IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly I .,._.Electrical above bottom ii r box outline of compatible boxes 7 NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor 1 - _J S4906-0011-3 11/2014 Intensity selection plug ,—t-f._.., accessible only from rear off I housing; factory setting is 177 Strobe intensity Removable cover, AN Shown for Reference viewing slot (tool is required to remove cover) 3 Is Single gang box remold V5744S) 2-1/4" (57 mm) deep, supplied by others 000 Handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, ) (' required for surface mount with handy box unless using the 4905-9926 wire guard Ceiling Mount High Candela Appliances Installation Reference 4" (102 mm) square box, Ceiling reference, surface mounted box 7 1-1/2" (38 mm) minimum depth Optional 4905-99151-9916 Adapter, Ceiling reference, recommended for surface mounted box flush mounted box Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side (VIO Reference ) Optional 4905-9927 Red Wre Guard Wring terminals are located behind the housing'\ Ceiling mount AN \ Optional 4905-9926 wire Ceiling mount strobe guard with mounting plate Strobe intensity viewing slot AN End View Intensity selection plug, accessible only from rear of lens housing; ReferenceJ K1 factory setting is 177 cd Surface Mounting Reference / ,-2975-9145 Box\ with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and 0 box shown for reference II 4" (102 mm) square O box profile, 1-1/2" ll (38 mm) deep L in i Wire Guard Optional 0 4905-9961 rc_ AN\ 1*1 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) S NOTE: V/O is shown for reference, AN mounts the same TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NT PA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4906-0011-3 11/2014 0 2014 7yco Fire Protection Products. All rig/Its reserved. All specifications and other information shown were current as of document revision dale and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0378 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 910 4007-9102, 4007-9201 and 4007-9202 Commercial Fire Alarm Control Panels. Local, auxiliary, remote station, releasing and central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 4007-9801; Zone/Relay Module 4007-9802; 25V Regulator Module 4007-9803; lDNet+Loop Module 4007-9804; Dual Class A Isolator Module 4007-9805; 24 Zone LED Module 4007-9806; SDACT Module 4007-9807; City Circuit Module with Disconnect Switch 4007-9808; City Circuit Module without Disconnect Switch 4007-9809; Alarm Relay Module 4190-8001; Remote Service Gateway . 0566-989; IDNAC Power Supply 0566-1023; CPU and User Interface 0566-1030; NAC Power Supply RATING: 2A @ 120 VAC 50/60 HZ 1A @ 240 VAC 50/60 HZ INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Alarm Verification shall not be implemented on initiation-device circuits thaqt have the option 10-27-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0378 Page 2 of 2 of releasing an extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. S 10-27-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0382 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: ModeIs-9202 andRemote LCD Color Touchscreen Annunciators. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annuciators for use with listee's separately listed Series 4007ES fire alarm control units (CSFM No. 7165-0026:378). Refer to manufacturer's Installation Manual for details. 04-23-15 gt This listing is based upon technical data submitted by the applicant. C.SFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION FROM OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0026:0216 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models(4098-9733] 4098-9733E, *40989734 *4098.9734E GSA4098-9733 or *GSA4098 9734 electric combination rate compensated, fixed temperature, and rate of rise heat detectors. Intended for use with *listees separately listed compatible detector bases. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 135°F and 155°F all models. 190°F (-9734 models only) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical/temperature ratings and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. fl *Rev. 02-18-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL a; S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM '4 LISTING SERVICE LISTING No. 7125-0026:0333 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4906-9109(Red Housing)/4906-91 11 (White Housing) strobe lights, 1 Hz, non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd, and 185cd. Intended for indoor use wall mounting only. Models 4906-9110(Red Housing)/4906-9112( White Housing) strobe lights 1 Hz, non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd and 185cd intended for indoor use ceiling mounting only. Models 4906-9139(Red Housing)906-9141i White Housing) audible signal appliance for the hearing impaired non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd, and 185cd. Intended for indoor use wall mounting only. 4906-9140(Red Housing)/4906-9142 (White Housing) audible signal appliance for the hearing impaired non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd and 185cd intended for indoor use ceiling mounting only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 24 VDC Flash Rate: 1 Hz Candela: 4906-9109, -9110, -9111, -9112, -9139, -9140, -9141, -9142: 135cd, 177cd, 185cd, INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models 4906-9109/4906-9111 and Models 4906-9139/4906-9141 are for wall mount only. Models 4906-9110(Red Housing)/4906-9112 and Models 4906-9139(Red Housing)/4906-9141 are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as High Candela Strobes and Horn/Strobes models 4906, -9109, -9111, -9139, -9141, -9110, -9112, -9140, -9142 suitable for the hearing impaired when used with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. Refer to Listee's Installation Instruction Manual for details. 05-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0333 Page 2 of 2 NOTE: IF] 05-22-09 fm i' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4906-9127, wall mount and Models 4906-9128 and ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed Product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation . Instruction Manual for details. NOTE: 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models* 4090-900), -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002\ -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: Recert. 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America Inc.25 Corporate Dr. Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MR..101ICIR *MR101SsEIC *MR101SSEIClR MR-104/C, *MR104/C/R, *MR10455E1C *MR10455E1C1R MR-201/C, MR201/C/*R, *MR201SSE/C *MR201SSE/CIR MR-204/C, MR204/C/*R, *MR204ssE/C *MR204..SSEICIR PAM-11, PAM-2, PAM-3, PAM-4, RIC-1, RIC-2, RIC-3, RIC-4, MR-RIC-301 /*C, *MRRIC301ICIR MRRIC305*/C, * MR-RIC-305/C/R, MRRIC401*/C, *MR..RlC..401/C/R MRRlC405*IC and *MRR1C405/C/R relay modules. *Models MR-ITM/C and MR-lTM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. • APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:0224 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models-9001, -9002, -9003, 04 *9005 *90069010 -9011, -9012, *9013 *9014 *9015 -9020, and *9021 non-coded addressable manual pull stations. Model 4099-9805 Conversion Kit, Models 4099-9001, *..9004 9010, *93 -9020 and *..9021 are single action stations. Models 4099*9005, -9011 and *..9014 are breakglass stations. Models 4099-9003, *9006 -9012 and *.9015 include a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9805 is a retrofit Kit handle for field conversion of a single action station to a NO GRIP station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. 40 APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Is Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models-9805,q6)-9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION flmw OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models(4098-97 14) -9714T5P, -971411P, -9754 -9754TSP, -97541TP; GSA4098-9714, and -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 9789T5P, -97891TP, -9791, -9791T5P, -979111P, -9792, -9792T5P, 9792TTP, -9793, 97931SP, -97931TP, -9794, -979415P,-9794TTP; G5A4098-9792, and -9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714T5P and -97141TP are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755T5P and -9755TTP duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, -9754T5P, -97541TP; GSA4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 40 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed *compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 12-02-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other • Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: ModeIs9069101, -9102, andmuIti-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 c INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation 0 Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 3O,2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlO0 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: ModeIs9780,-9780E, *9772 -9789, -9789E, 9789T5P, -9789TTP, -9791, -9791E, -9791 TSP, 9791TTP2 -9792E, -979215P, 97921TP, -9793,-9793E, -979315P, -9793TTP, -9794, -9794T5P, -979411P, -9795, -9795T5P, -97951TP, -9796, -9796T5P, -979611P; G5A4098-9780, -9792, -9793, -9795 and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and G5A4098-9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733, G5A4098-9733, *4098.9734 and *GSA40989734 heat detectors (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795T5P, -9795TTP, -9796, -9796TSP, -979611P; G5A4098-9795, and -9796 are only intended for use with Models 4098-9754 or G5A4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794T5P, -97941TP, -9795, -9795T5P, -9795TTP, *9772 and G5A4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 04-21-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct i operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 9 li CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4098-9755, *40989755TSp *40989755Up(4o9891 *40989756TSp *40989756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: 6 *Rev. 11-06-03 • This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to verify correct listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division m tqc a SimplexGrinnel/ SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgrinnell.com Appendix Item Description A Business License B Warranty 4 I Safer. Smarter. Tyco. TM tqca ell License Number 986047 SimplexGrinne!i LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGR[NNELL LP 12728 SHOEMAKER AVENUE SANTA FE SPRINGS, CA 90670 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2017 This license is current and active. All information below should be reviewed. CIO - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR r~- I Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $12,500 Effective Date: 08/13/2013 Bond of Qualifying Individual I . This license filed Bond of Qualifying Individual number 82332031 for MAYLE RONALD GILBERT in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 . This license filed Bond of Qualifying Individual number 82332035 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers Compensation This license has workers compensation insurance with the ACE AMERICAN INSURANCE COMPANY Policy Number: WLRC48018737 Effective Date: 10/01/2014 Expire Date: 10/01/2015 Workers' Compensation History SimplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 tq nell www.simplexgrinnell.com SJMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 5:00PM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST Safer. Smarter. TyCo.TM