Loading...
HomeMy WebLinkAbout6010 HIDDEN VALLEY RD; 105; FPC2017-0187; Permit(ity of PERMIT REPORT Carl sbad Print Date: 10/14/2021 Permit No: FPC2017-0187 Job Address: 6010 HIDDEN VALLEY RD, # 105, CARLSBAD, CA 92011-4219 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120406800 Track U: Applied: 07/12/2017 Valuation: $51,254.02 Lot U: Issued: 08/09/2017 Occupancy Group: Project U: Finaled Close Out: 08/12/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: DR. ANNAKARINA DEANGELIS DENTAL OFFICE -FIRE ALARM TI FPContractor: DIALCOM SYSTEMS GROUP P0 BOX 462166 ESCONDIDO, CA 92046-2166 (760) 520-5044 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov IL CD Inc. I FIRE ALARM SIIBMITTTAL FOR Dr. Anakarina DeAngelis 6010 Hidden Valley Rd # 105 Carlsbad, CA 92011 Submitted by: DIALCOM SYSTEMS GROUP, INC. P.O. Box 462166 Escondido, CA 92046 FPC20I7-0187 6010 HIDDEN VALLEY RD UNITIO5 1 Dialcom Systems Group, Inc. Phone 760-520-5044 * Fax 760-839-5892 *C10 703343 * ACO 7107 PROJECT INFORMATION SHEET INSTALLING CONTRACTOR: CONTRACTORS LICENSE: PROJECT MANAGER: PROJECT NAME: DIALCOM SYSTEMS GROUP 1541 SIMPSON WAY ESCONDIDO, CA 92029 C-10 703343 DENNIS DIAL Dr. Anakarina DeAngelis PROJECT ADDRESS: 6010 Hidden Valley Rd # 105 Carlsbad, CA 92011 SCOPE OF WORK: Fire Alarm System Tenant Improvement REFERENCE: Dr. Anakarina DeAngelis 6010 Hidden Valley Rd # 105 Carlsbad, CA 92011 Dialcom Systems Group is pleased to submit the following equipment for your review and approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinkled and monitored. QTY MODEL NO DESCRIPTION CSFM 1 MIRBPS10A FIRE ALARM POWER BOOSTEP(0s77i j) 7300-1483:0174 3 EGCF-VM STROBE (CEILING MTD.) 7125-1657-0219 3 EGCF-HDVM HORN-STROBE (CEILING MTD) 7125-1657:0202 1 7 Z 909)LAP47"M Fire & Life Safety t Power Supplies and Accessories Remote Booster Power Supplies MIRBPS6A, MIRBPS1 OA Overview The Booster Power Supply (MIRBPS) is a UL 864, 9th Edition list- ed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. The MIRBPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the MIRBPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The MIRBPS has four Class B (convert- ible to two Class A) NACs. These can be activated in one or two groups from the MIRBPS's unique dual input circuits. The MIRBPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The MIRBPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description 01-864 9th edition (UOFire Alarm Systems UL636 (NlEL UEHX7) Holdup Alarm Units and Systems UL609 (AOTx, AOD(7) Local Burglar Alarm Units and Systems UL294 (ALW, UEHX7) Access control Systems UL365 (APAW, APAW7) Police Station connected Burglar Alarm Units and Systems UL1076 (APOU, APOU7) Propiletary Burglar PJarrn System Units UL161O (AMC) central Station Alarm Unit ULC-5527 (UO)O(C) Control Units, Fire Alarm (Canada) ULC-5303 (AOTX7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identity wing or internal faults Standard Edwards keyed lockable steel cabinet with remov- able door 110 and 230 Vac models available Accommodates 18 to 12 AWO wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page lof4 DATA SHEET M85005-0125 Not t be ,, .tO 'O t ,Lton pc. e Issue 4 Power-limited wiring area Application The MIRBPS provides additional power and circuits for notification appliances and other 24 Vdc loads. It is listed for indoor dry loca- tions and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the MIRBPS input sense circuit and the trouble relay f programmed). While this provides indication to the host system, the MIRBPS can still be activated upon command. A separate AC Fail contact is available on the MIRBPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the MIRBPS can be activated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The MIRBPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. MIRBPS NACs can be configured for a 3-3-3 temporal or continu- ous output. California temporal rate outputs are also available on certain models. This makes the MIRBPS ideal for applications re- quiring signaling rates that are not available from the main system. Dimensions Top View J D5 Q 00 D2-1 I D3 0 (1) &4— D4 —.0 0 Front View 0- H > (1) 65 0 6 0 . CO Ei All knockouts CD I for 3/4 in conduit <I (1.9 cm) I Dl 02 D3 04 05 06 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) Dl Engineering Specification Supply, where needed, Edwards MIRBPS Series Booster Power Supplies (MIRBPS) that are interconnected to and supervised by the main system. The MIRBPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compli- ment. The MIRBPS battery compliment shall be sized to match the requirements of the main system. The MIRBPS shall be ca- pable of supervising and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communica- tion (MNEC), life safety and security applications, and the capacity of 65 ampere-hours for access control applications. <<The MIRBPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The MIRBPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. MIRBPS NACs shall be convertible to a minimum of two Class A NACs. Each MIRBPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be provided with automatically restoring overcurrent protection. The MIRBPS shall be operable from the main system NAC and/ or Edwards Signature Series control modules. MIRBPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the MIRBPS shall not impede operation of main system NAC. The MIRBPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 o14 Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL FPLR, or FPLP cable per NEC. 121 Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. [31 Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. -M85005-0125 r ii - , Issue In addition to the internally generated signal rates, the MIRBPS can also be configured to follow the coded signal rate of the main \IVlre routing system NACs. This allows for the seamless expansion of existing NACs. The MIRBPS enclosure has mounting brackets for up to three Signature modules to the right of the circuit board. Route AC supply through these knockouts only (Nonpower-limited and supervised) 0 Data in from previous device or Signature controller 0 Notification appliance circuit (NAC) Ir UL listed =DEK] EOL 15 KIN Notification appliance circuit (NAC) UL listed EOL 15KW EOL 47K EOL47K 109 CC1(S) module 00 CG1(S) module 00 Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the boosters terminals. This allows multiple boosters to be driven from a single NAC circuit without the need for special configurations. NAC Circuit F To next signaling NAG Circuit _______________ \J device, booster; or EOL resistor 0 M a I ) NAG Output #1 Fire Alarm _______ ) NAG Output #2 Control Panel to ° I ) NAC output #3 ) NAC output #4 0 c Booster Power Suolv Configuring the Booster for Multiple CC1 (S) modules using the AC Power Fail delay operation* MlRBPSs sense inputs Notification appliance circuit (NAC) UL listed EOL 15 kO Notification appliance circuit (NAC) UL listed EOL 15 kO 47 1(0 CC1(S) module [1 ](31 00 -. • • Data in from \J I Lj_. Data out to 11 previous device 5_J next device modul or Signature controller Data out to The Booster supports AG Power fail delay of three hours via its trouble contact when J next device dip switch SW2-6 is on. AU other troubles are reported to supervising module or panel without delay via Sense inputs. [3) Security and access BPS 24V CNAC4/ / + - / + ±foc12 - / + - - [1] Disable the MIRBPS's ground fault jum 12 V Security Security cud EOL device qjde:vi:ce!]= device To next device or end Page 3of4 DATA SHEET M850050125 Not to b used for inbiillution purposes. Issue4 Specifications Model 6.5 amp Booster 10 amp Booster AC Line Voltage 120VAC or 220-240VAC 50/60Hz I 120VAC or 220-240VAC 50/60Hz 390 watts I 580 watts Notiticatiorl Appliance 3.0A max. per circuit © 24Vdc 3-OA max. per circuit @24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Trouble Relay 2 Amps © 30Vdc Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current (from an existing NAC) 3mA © 12Vdc, 6mA @ 24Vdc Booster Internal 70mA Supervisory Current Signature Mounting Space Accomodates three two-gang modules. 10 Amp Hours (2 of 12V1 OA) in cabinet up to 24 Amp hours with ex- Maximum Battery Size ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing @ 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model MIRBPSCAA provides selection for California rate, in place of temporal Maximum of 8 Amps can be used for auxiliary output ~F— TC Fire 8 Security Company Detection & alarm since 1872 U.S. T 888 244 9979 F 866-503-3996 Canada 1 705 875 2659 F 705 944 8861 Southeast Asia 1: +65 6391 9300 F +65 6391 9306 India 1: +91 80 4344 2000 F : +91 80 4344 2050 Europe 1+322725 11 20 F+322721 8613 Latin America 1305 593 4301 F 305 593 4300 utcfireandsecunty.com © 2010 UTC Fire & Security. All rights reserved. Ordering Information Catalog Number Description Shipping Wt. lb Ike 6,5 Amp Booster Power MIRBPS6AC 6.5 Amp Booster Power Supply (ULC) 13(5.9) MlRBPS6N230 6.5 Amp Booster Power Supply (220\f) 13(5.9) MlRBPS6C4A 6.5 Amp Booster Power Supply with California rate 13(5.9) 10 Amp Booster Power MIRBPS1 OAC 10 Amp Booster Power Supply (ULC) 13(5.9) M1RBP510N230 10 Amp Booster Power Supply (220\') 13(5.9) MIRBPS10CM 10 Amp Booster Power Supply with California rate 13(5.9) Related Equipment 12V6A5 7.2 Amp Hour Battery, two required 3.4 (1.6) 12V1 OA 10 Amp Hour Battery, two required 9.5 (4.3) 3-TAMP Tamoer switch BC-1 Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) 12V24A 24 Amp Hour Battery, two required (see note 1) 20 (9.07) 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40 (18.14) 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Requires installation of separate battery cabinet. MIRBPS supports batteries greater than 24 Amp hours for access control applications only. Page 4 of 4 M85005-0125 Issue -' CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0174 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models MIRBPS6A, MIRBPSIOA, MIRBPS6A/230, and M1RBP510A1230 remote booster power supplies. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1657:0229 Rev. 6-9-11 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division EST Cata!og D Strobes, Horns, Bells, Chimes \-EST ", I Life Safety & Communications Field Configurable ,,---~OERf ~~~-~, Ceiling Strobeslap Genesis Series One or more patents pending. if MEA C ( 7125-1657: 0219 55389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullUght technology. FullUght strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable -no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use Page 1 of 4 DATA SHEET 85001-0557 Not to be used for installation purposes. Issue 7 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. Al Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/8 (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8dia. (173 mm) I 1.0 (25 mm) -- . 0.60(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - 0. Angle - Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output setting is changed by simply opening the 7 device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These deviceswill not operate without electrical power. Asfiresfrequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 90• IS. U fIJ.' To listed To next appliance, fire alarm end-of-line control I or return to panel I control equipment DATA SHEET 85001-0557 Page2of4 Not to be used for installation purposes. Issue 7 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value ECS/MNS appliances are selectable by A, B, C, or D designations. Light output setting, standard models Light output setting, high output models UI. "15" or "D" "30" or "C" "75" or "B" "95" or "A" "95" or "D" 0115" or "C" "150" or "B" "177" or "A" Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 I Light output setting, standard models Light output setting, high output models Typical "15" or "0" 030" or "C" "75" or "B" "95" or "A" 1195" or "D" "115" or "C" "150" or "B" f "177" or "A" Current RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 24 Vdc 63 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16Vfwr 126 187 368 403 484 570 673 724 20 VW 108 156 281 333 380 438 537 604 24Vfwr 97 139 240 270 318 361 434 484 33Vfwr 89 119 197 214 245 269 308 338 Current values are shown in mA Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). M Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Mounting Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. 16to33Vdc, 16 to Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UI. 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 Cd (GC-VMH) GC-VM series strobes: non-coded, filtered 16-33 Vdc Strobe operating voltage or unfiltered 16-33 Vdc FWR. GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SlGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS10A, APS6A, APS10A, i064, i0500, Fireshield Plus 3, 5 and 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. Page 3of4 DATA SHEET 850010557 Not to be used for installation purposes. Issue 7 Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Model I Housing I Marking I Lens I Strobe Ship Wt. Life safety Appliances (c/w running man icon screen printed on housing) GC-VM White None Clear Selectable 15, 30, 75, or 95 cd 1.8 lb. (0.82 kg.) GCF-VM White "FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95,115,150, or 177 c GCF-VMH White "FIRE" ECS/MNS Appliances (no running man icon on housing) GCWA-VMA White Alert" Amber Selectable A, B. C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA 'Alert" Amber Selectable high output A, B, C or D I GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Clear Units with red, blue or green lenses are available as a special order. Contact customer service for details. United TehnoIagI ' Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards... Email: inquines@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 0 P Page 4of4 DATA SHEET 85001-0557 Not to be used for installation purposes. Issue 7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0219 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: - Models GC-VMGCF:VM, GCFR-VM, GCVMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWN_VMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G1M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CCIS (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division GE [ST Fire & Life Safety Security Strobes, Horns, Bells & Chimes Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling. Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, GE Security Genesis strobes do not require bulky specular reflectors and lenses. Instead, on exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts em- ploying this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak. Models with "FIRE" mark- ings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Field Configurable I Pending ce i ling Horn-Strobes One or more patents pending. Genesis Series ---- , -;' Data Sheet 85001-0559 Issue 8 Not to be used for installation purposes. Page 1 of 4 next device end of line device Note: Strobes must have continuous voltage. Application Genesis strobes are UL 1971-listed for use indoors as ceiling- mounted public-mode notification appliances for the hearing im- paired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 d8A )87dBA in Canada), where occu- pants use hearing protection, and in areas of public accommoda- tion as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as wall-mounted public-mode notification appliances for the hearing impaired. Prevail- ing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. Al) Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. GE Security recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excellent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about S dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 d8 above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet 11.5 ml above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Dimensions Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electri- cal box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. GE Security recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB out- put may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Doubling the distance from the signal to the ear will theoretically Polarity result in a 6 dB reduction of the received sound pressure level. The alarm actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. 0 (173 ) 1.0 : (25 mm) 0.60(15 mm) Data Sheet 85001-0559 Issue 8 Not to be used for installation purposes. Page 2 of 4 Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting UL 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVM Temporal Horn-strobe: Low dB Setting GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. GE Security recommends using the Typical Current for system design including MAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. S. Fuses, circuit breakers and other avercurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. 6. Our industry has used 'mean' currents over the years. However. UL will direct the industry to use the 2004 RMS values in the future. dBA_output - Light output - (effective cd) Percent of UL rating versus angle Low dB Setting U1464 Average Peak Temporal Steady Temporal/ Steady Temporal/ Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 1 80.9 85.9 1 91.8 1 95.1 Notes 1. All values shown are dBA measured at 10 feet 13.01ml: 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic chamber. Data Sheet 85001-0559 Issue 8 Not to be used for installation purposes. Page 3 of 4 High dB UL464 Average Peak Setting Temporal Steady Temporal/ Temporal/ PtZCCNS ULRfl1g Steady Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 1 95.7 98.7 GE Security Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarboriate (clear) Mounting North-American 4" square box. 2 1/8)54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm') wire size Operating environment Indoor: 32-120F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-5541, year 2004 UL requirements for standards Agency listings/approvals UL1638 and UL1971, and complies with UL1480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA. FM pending. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Operating voltage Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G1M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd IGC-HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional G1M Genesis Signal Master indefinitely Strobe flash rote within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on some circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rote Horn pulse rate synchronized with optional G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF. ½ sec ON, 11h sec OFF, then repeat cycle U.S. 1888-378-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 vw.gesecurity.com/est © 2007 General Electric Company All Rights Reserved. Genesis Series is a trademark of GE Security Ordering Information Catalog Housing Number Color GC-HDVM White Marking Description None Ship Wt. lbs Ilia) GCF-HDVM White "FIRE" Genesis Ceilingf\NoIl Horn-Strobe with selectable 15, 30, 75, or 95 cd output GCFR-HDVM Red "FIRE" 0.82 (1.81 GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories G1M-RM Genesis Signal Master -Remote Mount 11-gong) 0.2 (0.1) SIGA-CC15 Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIOI 0.18 10.081 white Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. imagination at work Data Sheet 85001-0559 Issue 8 Not to be used for installation purposes. Page 4 of 4 I ' . CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r1i77 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0202 Page 1 of 1 CATEGORY: 7125- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST' GI-HV15, -HV30, -HV60, -HV-75, G1-HOVI5, -HOV30, -HOV60, -HOWS, -HOV1I0, GIF-HOVI5, -HOV30, -HOV60, -HOWS, -HOV110, GIRF-HOVI5, -HOV30, HOV60, -HOWS, -HOVI10, GI-HDVM, G1R-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, GI-HDV1575, G1R-HDV1575, G1F-HDV1575, and G1RF-HDV1575 horn/strobes with or without suffixes -Rand-F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. tl RATING: Electrical: 24-30 Vdc 16-33dcNfwr - Models G1-HDVM, GIR-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, GIR-HDV1575, GI F-HDV1575, Gi RF-H0V1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models GI-HDV1575, Gi R-HDVI 575, Gi F-HDV1575, Gi RF-H0V1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division