Loading...
HomeMy WebLinkAbout6005 HIDDEN VALLEY RD; 110; FPC2021-0073; Permit4ity of PERMIT REPORT Carlsbad Print Date: 09/14/2021 Permit No: FPC2021-0073 Job Address: 6005 HIDDEN VALLEY RD, # 110, CARLSBAD, CA 92011-4223 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120406600 Track #: Applied: 05/07/2021 Valuation: $465,100.00 Lot #: Issued: 06/15/2021 Occupancy Group: Project #: Finaled Close Out: 09/14/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: DESIGN THERAPEUTICS (THE CROSSINGS) -SPRINKLER TI (80 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov XLH Recessed Pendent FP - Bulletin 014 Rev. L Model Fl FR Series Quick Response Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH *NSF Certified to NSF/ANSi Standard 61 Annex C EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, LILIU Upright Pendent 11-41-1 , ills Vertical Sidewall Horizontal Sidewall Recessed Concealed Horizontal Sidewall Pendent XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. - Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 'Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 14FCO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL0) K5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL(l) K 4.2 Response (R1/2) 175 PSI 7 PSI 'Temperature 'Finish Table" Fl FRXLH Ratings" Table. F1FR28 K2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°c Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy5lO CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US F Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 3,4, 6 I 7/16" (10mm) 1/2" NFl (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA14134> 3/8" (10mm) 1/2" NFl (R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA14114 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NFl (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753> cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant ii Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor _______________ Sprinkler __________ Approval __________ Sprinkler Identification Number (SIN) Size US J Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1,5 RA1415 (11mm) 1/2" NFl (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1410 cULus listed corrosion resistant (Polyester coated) sprinkler. 03) *DuPont Registered Trademark 3. 4. Vertical Sidewall *DuPont Registered Trademark Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4(102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(l) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16' (10mm) 1/2" NFl (R1/2) 1 4.2 60 1 2.25" (57mm) RA1413 3/8" (10mm) 1/2" NPT(lR1/2) 1 2.8 40 1 2.25" (57mm) RA1411 " Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler 1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) 1/2" NFl (R1/2) 4.2 60 1 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions • 'j r I I / \ r Jo F C(OF CCLLVO aumsc.a a I I - A OW OFCESS - AlT MMMUM RETEOS - L - F2 flO,TJo4 ADAJSTA(Dff AT RMW V819 5—] /2p2 ?,,,,J AaAam ar .000u - 7/8j21.2mr,) AT wmwuw RS F3 £SJoSFOFSVV RECESS: ç Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Fl or F2 1 X W U5R 2 5,r Os.. (6?m,nJ ?W IN CDLLW I I I I 2 5/56 054. CUP CEYLw FAZE OF MEW FACE OF 051JNG A AMXOWM RE - I-I/2T3&,,,,,J j T T MM MOWN " 05 - ?T25.4,n,nJ J7I17 I AT *MXINW4 RECESS - 9/I67I43.raoJ I AT MINIMUM RECESS - I724ornJ (82MU,,J Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model 0 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NFl (R112) 5.6 80 2.25" (57mm) 1, 2, 3 RA1485121131 15mm ½" NFl (R1/2) 5.6 80 2.25" (57mm) 3(1) "LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon®)" Plated - cULus listed corrosion Resistant Horizontal Sidewall MOdel Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA14351623 ( cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. Electroless Nickel PTFE (leflonR)* Plated - cULus listed corrosion Resistant FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4779mm1 AT MINIMUM RECESS = 3/879.5mm] 2 7/4" HOLE OIA. (5 7.2mm] 7" X 7/2" REDUCER 7 75/76" OIA.\fJ (49.2mm] ",12 TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON AT MAXIMUM RECESS = 7-3/8734.9mm] AT MINIMUM RECESS = 2-7/76752.4mm] AT MAXIMUM RECESS = 1-5/8747.3mm] AT MINIMUM RECESS 2-7/76752.4mm] I [3.2mm] 2 27/32" 014. (72.2mm] Fl ESCUTCHEON [ 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2 712. 7mm] ADJUSTMENT I (7) 4"-72" [707.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4 - 6" [70 7.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model AOl Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½" (15mm) 5.6 80 ½" NPT F1FR 1350F/570c 1350F/570c 100°F/380c Orange 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 155°F/680c 135°F/57°c 100°F/38°c Red 6 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 1750F/790c 1650F1740c 100°F/380c Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 200°F/930c 1650F,740c 150°F1650C Green 1 RA1414 (1) For VdS only = 1551F/680c Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor I I Thread Size I Model Temp. Rating Max. Ambient Bulb Color Approvals Sprinkler Identification US Metric Sprinkler I I Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/930c 1650F40c 150°F1650C Green 1,5 RA1414 *DuPont Registered Trademark 5. —2 5/6" OIA. HOLE IN CEILING I 112" MAX FACE OF FIrTING _,._.,_....TO FACE OF CEILING DIMENSION 15/16" 2 5/16" 0/A - CUP CEILING—' - 1/2" MAX. 1 COVER ADJUSTMENT COVER PlATE— ASSEMBLY 5/16"OIA. SPRINKLER 2 5/16 0/A - CUP - CEILING- 5/16" MAX. COVER ADJUSTMENT COVER PLATE- ASSEMBLY 5/16" 0/A. SPRINKLER - 2 5/8" 0/A. HOLE IN CEILING I 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" "x 1/2" REDUCING TEE OR ELBOW 7" x 1/2 REDUCING TEE OR ELBOW CONCEALED. 1 /2" ADJUSTMENT Figure 1 Installation Aid A protective cap is included for use during installation, Important: The F1FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown, The Model El or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model D Sprinkler Wrench, Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers, Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½" orifice, 1/2" NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (681C), 175°F (79°C) or 200°F (930C), The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C), The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FlFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 6. CONCEALED, 5/16" ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High" 1 141 1 286 1 2250F (1070C) I Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl F2 or FP escutcheons for "light hazard" only while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate01 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate" Electroless Nickel PTFE(Teflon®)*)7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated I Black Plated Black Paint Black Paint(2X6) Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance' applies to SIN Numbers RA1435 (HSW), RA1485(vsw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated' applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies onlyto RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered. the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7.