Loading...
HomeMy WebLinkAbout3677 GARFIELD ST; ; FPR2021-0001; PermitPERMIT REPORT ILbty of Carlsbad Print Date: 08/31/2021 Permit No: FPR2021-0001 Job Address: 3677 GARFIELD ST, CARLSBAD, CA 92008-8219 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2042320400 Track #: Valuation: $419,210.40 Lot #: Occupancy Group: Project #: #of Dwelling Units: S Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #:. Project Title: H ERNANDEZ RESIDENCE Description: HERNANDEZ - NEW 13D SPRINKLERS FOR NEW SFR (30 HEADS) Single Family Fire Sprinkl Applied: 01/05/2021 Issued: 02/04/2021 DEV2019-0158 Finaled Close Out: 08/31/2021 Inspector: Final Inspection: Applicant: S FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELAZUMAYA S 12155 PAINE PL 12155 PAINE PL POWAY, CA 92064-7154 POWAY, CA 92064-7154 5 (619) 588-6364 (619) 588-6364 FEE S AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) S $125.00 FIRE NFPA 13D Single Family System (Plan Review) S $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department S S Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov • IILI..lLC 12155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR HERNANDEZ GARAGE FILE NUMBER: 20-0694-GARAGE.SDF DATE: DECEMBER 18, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/ 512 sq.ft. AREA OF APLICATION: GARAGE COVERAGE PER SPRINKLER: 256 sq.ft. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 33.2 gpm TOTAL WATER REQUIRED (including hose): 38.2 gpm FLOW AND PRESSURE (@ BOR): 23.2 gpm @ 44.3 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD WATER DEPARTMENT CONTACT: KAREN WATER PRESSURE INFORMATION: 83.0 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATi: 12.20/2020RAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329-GARAGE.SDF JOB TITLE: HERNANDEZ GARAGE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQD NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 74.4 73.0 500.0 74.4 38.2 73.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 38.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 33.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 -2.0 SOURCE 73.8 38.2 2 0.0 - - - - 60.4 - - - 3 0.0 - - - - 56.4 - - - 4A 3.0 - - - - 51.0 - - - 4B 0.0 - - - - 48.3 - - - 5 2.0 HOSE STREAM 44.3 5.0 6 9.5 - - - - 37.0 - - - 7 9.5 - - - - 17.8 - - - 7A 9.0 K= 4.90 17.0 20.2 8A 9.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATy. 12/20/2020RAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329-GARAGE.SDF JOE TITLE: HERNANDEZ GARAGE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 38.2 0.995 PL 25.00 PF 12.5 1 -2.0 SRCE 73.8 (N/A) 15.8 150 FTG TG PE -0.9 2 0.0 0.0 60.4 0.0 0.369 TL 34.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 60.4 0.0 4.0 psi, 38.2 gpm 3 0.0 0.0 56.4 0.0 Pipe: 3 38.2 1.590 PL 85.00 PF 4.1 3 0.0 0.0 56.4 0.0 6.2 150 FTG 2E4L PE -1.3 4A 3.0 0.0 51.0 0.0 0.038 TL 109.00 PV Pipe: 4 38.2 1.590 PL 75.00 PF 4.0 4A 3.0 0.0 51.0 0.0 6.2 150 FTG ET4L PE 1.3 4B 0.0 0.0 48.3 0.0 0.038 TL 105.00 PV Pipe: 5 38.2 1.025 PL 5.00 PF 3.2 4B 0.0 0.0 48.3 0.0 14.9 150 FTG EL PE -0.9 5 2.0 H.S. 44.3 5.0 0.319 TL 10.00 PV Pipe: 6 33.2 1.101 PL 7.00 PF 4.0 5 2.0 H.S. 44.3 5.0 11.2 150 FTG ET3RC PE -3.2 6 9.5 0.0 37.0 0.0 0.174 TL 23.00 PV Pipe: .7 33.2 0.874 PL 18.00 PF 19.3 6 9.5 0.0 37.0 0.0 17.8 150 FTG 3E3R PE 0.0 7 9.5 0.0 17.8 0.0 0.535 TL 36.00 PV Pipe: 8 20.2 0.874 PL 0.50 PF 1.0 7 9.5 0.0 17.8 0.0 10.8 150 FTG TR PE 0.2 7A 9.0 4.9 17.0 20.2 0.214TL 4.50 PV Pipe: 9 13.0 0.874 PL 112.00 PF 10.9 7 9.5 0.0 17.8 0.0 7.0 150 FTG TR PE 0.2 8A 9.0 4.9 7.0 13.0 0.094 TL 116.00 PV NOTES (HASS): Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2019) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.009 gpm and a maximum imbalance at any node of 0.077 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE,: 12420/2020RAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329-GARAGE.SDF JOB TITLE: HERNANDEZ GARAGE TWO HEAD CALC Total pressure at each node is used in balancing the system. Maximum water velocity is 17.8 ft/sec at pipe 7. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 74.39 psi with a flow of 38.38 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Lii Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter . Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 12120/2020RAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329-GARAGE.SDF JOB TITLE: HERNANDEZ GARAGE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 74.40 psi Resid: 73.00 psi Flow: 500.0 gpm [:LIWI] 2 70.0 60.0 G A U 50.0 G E 40.0 P R E 30.0 S S U 20.0 R E 10.0 LEGEND 1 Available pressure 74.39 psi 8 38.2 gpm 2 1 Required pressure 73.80 psi 8 38.2 gpm Source Supply Curve System Demand Curve p 5 0.0 i -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DARE: 1?/20/2020RA1'1 FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329-GARAGE.SDF JOB TITLE: HERNANDEZ GARAGE TWO HEAD CALC WATER SUPPLY CURVE 84+ 77+ 0\\\\\\\\\\\\\\\\\ X * <-73.0 psi @ 500 gpm I Flow Test Point 70+ 63+ P56+ R I S I S I 5 49+ U I R I E I 42+ P I S I I 35+ 28+ 21+ 14+ LEGEND I, I X = Required Water Supply I 73.80 psi 8 38.2 gpm 7+ I 0 = Available Water Supply 74.39 psi 8 38.2 gpm +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) ff neSeOf..oI'..'E • UCOOLJ flOC PIJL • flE L$.fl.O LE 12155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR HERNANDEZ RESIDENCE FILE NUMBER: 20-0329.SDF DATE: DECEMBER 18, 2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/ 400 sq.ft. AREA OF APLICATION: BEDROOM COVERAGE PER SPRINKLER: 400 sq.ft. NUMBER OF SPRINKLERS: I SPRINKLER TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR): 21.0 gpm @36.4 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD WATER DEPARTMENT CONTACT: KAREN WATER PRESSURE INFORMATION: 83.0 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: I2/20/2020 C:\PROGPJ-\M FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW NODE PRESS. PRESS. @ TAG (PSI) (PSI) (GPM) 1 74.4 73.0 500.0 AVAIL. TOTAL REQ'D PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) 74.4 26.0 54.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 -2.0 SOURCE 54.0 26.0 2 0.0 - - - - 47.0 - - - 3 0.0 - - - - 43.0 - - - 4A 3.0 - - - - 39.7 - - - 5 5.0 HOSE STREAM 36.4 5.0 6 14.5 - - - - 30.5 7 15.5 - - - - 21.3 8 25.5 - - - - 16.9 - - - 9 25.5 - - - - 16.8 - - - 9A 27.0 - - - - 16.2 - - - 10 25.5 - - - - 16.8 - - - 10A 27.0 - - - - 16.2 - - - 11 25.0 - - - - 17.0 12 15.5 - - - - 21.1 13 15.5 - - - - 20.9 13A 15.0 K= 4.90 18.4 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DP4JE: 172/20/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 26.0 0.995 PL 25.00 PF 6.2 1 -2.0 SRCE 54.0 (N/A) 10.7 150 FTG TG PE -0.9 2 0.0 0.0 47.0 0.0 0.181 TL 34.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 47.0 0.0 4.0 psi, 26.0 gpm 3 0.0 0.0 43.0 0.0 Pipe: 3 26.0 1.590 PL 85.00 PF 2.0 3 0.0 0.0 43.0 0.0 4.2 150 FTG 2E4L PE -1.3 4A 3.0 0.0 39.7 0.0 0.018 TL 109.00 PV Pipe: 4 26.0 1.025 PL 5.00 PF 2.3 4A 3.0 0.0 39.7 0.0 10.1 150 FTG TL PE -0.9 5 5.0 H.S. 36.4 5.0 0.157 TL 15.00 PV Pipe: 5 21.0 1.101 PL 8.00 PF 1.8 5 5.0 H.S. 36.4 5.0 7.1 150 FTG ET3RC PE -4.1 6 14.5 0.0 30.5 0.0 0.074 TL 24.00 PV Pipe: 6 21.0 0.874 PL 16.50 PF 8.8 6 14.5 0.0 30.5 0.0 11.2 150 FTG 4E2R PE -0.4 7 15.5 0.0 21.3 0.0 0.229 TL 38.50 PV Pipe: 7 1.9 0.874 PL 12.00 PF 0.1 7 15.5 0.0 21.3 0.0 1.0 150 FTG ET2R FE -4.3 8 25.5 0.0 16.9 0.0 0.003 TL 22.00 FV Pipe: 8 0.8 0.874 FL 38.00 PF 0.1 8 25.5 0.0 16.9 0.0 0.4 150 FTG 9E8T FE 0.0 9 25.5 0.0 16.8 0.0 0.000 TL 107.00 PV Pipe: 9 0.0 0.874 FL 11.50 PF 0.0 9 25.5 0.0 16.8 0.0 0.0 150 FTG 4ETR FE -0.6 9A 27.0 0.0 16.2 0.0 0.000 TL 35.50 PV Pipe: 10 0.8 0.874 FL 7.00 PF 0.0 9 25.5 0.0 16.8 0.0 0.4 150 FTG ---- FE 0.0 10 25.5 0.0 16.8 0.0 0.000 TL 7.00 PV Pipe: 11 0.0 0.874 FL 13.50 PF 0.0 10 25.5 0.0 16.8 0.0 0.0 150 FTG 4ETR PE -0.6 10A 27.0 0.0 16.2 0.0 0.000 TL 37.50 PV Pipe: 12 0.8 0.874 PL 17.50 PF 0.0 10 25.5 0.0 16.8 0.0 0.4 15.0 FTG 6E4T PE 0.2 11 25.0 0.0 17.0 0.0 0.000 TL 59.50 PV Pipe: 13 -1.1 0.874 PL 33.00 PF 0.1 11 25.0 0.0 17.0 0.0 0.6 150 FTG 9E2T FE -0.2 8 25.5 0.0 16.9 0.0 0.001 TL 84.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: l2/20/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 1.9 0.874 PL 10.00 PF 0.0 11 25.0 0.0 17.0 0.0 1.0 150 FTG 2R PE 4.1 12 15.5 0.0 21.1 0.0 0.003 TL 12.00 PV Pipe: 15 1.9 0.874 PL 60.50 PF 0.2 12 15.5 0.0 21.1 0.0 1.0 150 FTG 2E3T PE 0.0 13 15.5 0.0 20.9 0.0 0.003 TL 79.50 PV Pipe: 16 21.0 0.874 PL 3.00 PF 2.8 13 15.5 0.0 20.9 0.0 11.2 150 FTG ETR PE 0.2 13A 15.0 4.9 18.4 21.0 0.229 TL 12.00 PV Pipe: 17 -19.1 0.874 PL 1.00 PF 0.4 13 15.5 0.0 20.9 0.0 10.2 150 FTG R PE 0.0 7 15.5 0.0 21.3 0.0 0.193 TL 2.00 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2019) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.031 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.2 ft/sec at pipe 16. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 74.39 psi with a flow of 30.98 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 12/20/2020 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 12/20/2020 C:\PROGRAI4 FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC WATER SUPPLY ANALYSIS Static: 74.40 psi Resid: 73.00 psi Flow: 500.0 gpm 1 70.0 60.0 G A 2 U 50.0 G E 40.0 P R E 30.0 S S U 20.0 R E 10.0 LEGEND 1 A Available pressure 74.39 psi @ 26.0 gpm 2 M Required pressure 54.00 psi @ 26.0 gpm Source Supply Curve System Demand Curve -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 EATE: 12/20/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE ONE HEAD CALC WATER SUPPLY CURVE 84+ 77+ 0\\\\\\\\\\\\\\\\\ I * <-73.0 psi @ 500 gpm Flow Test Point 70+ 63+ P56+ R X E I S I S 49+ U I R I E I 42+ P I S I I 35+ 28+ 21+ 14+ LEGEND I X = Required Water Supply I 54.00 psi @ 26.0 gpm 7+ 0 = Available Water Supply l 74.39 psi @ 26.0 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) ;. . 12155 PAINE PLACE P0 WAY, CA 92064 HYDRAULIC CALCULATIONS FOR HERNANDEZ RESIDENCE FILE NUMBER: 20-0329.SDF DATE: DECEMBER 18,2020 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/ 512 sq.ft. AREA OF APLICATION: EXERCISE COVERAGE PER SPRINKLER: 256 sq.fi. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.1 gpm TOTAL WATER REQUIRED (including hose): 31.1 gpm FLOW AND PRESSURE (@ BOR): 26.1 gpm @ 47.6 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD WATER DEPARTMENT CONTACT: KAREN WATER PRESSURE INFORMATION: 83.0 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE:12/2 /2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 74.4 73.0 500.0 74.4 31.1 69.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 -2.0 SOURCE 69.3 31.1 2 0.0 - - - - 59.8 - - - 3 0.0 - - - - 55.8 - - - 4A 3.0 - - - - 51.7 - - - 5 5.0 HOSE STREAM 47.6 5.0 6 14.5 - - - - 40.8 7 15.5 - - - - 27.1 8 25.5 - - - - 19.5 - - - 9 25.5 - - - - 11.2 - - - 9A 27.0 K= 4.90 7.2 13.1 10 25.5 - - - - 11.2 - - - bA 27.0 K= 4.90 7.0 13.0 11 25.0. - - - - 18.3 - - - 12 15.5 - - - - 23.0 13 15.5 - - - - 27.0 13A 15.0 - - - - 27.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE 12//2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 25.00 PF 8.6 1 -2.0 SRCE 69.3 (N/A) 12.8 150 FTG TG PE -0.9 2 0.0 0.0 59.8 0.0 0.253 TL 34.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 59.8 0.0 4.0 psi, 31.1 gpm 3 0.0 0.0 55.8 0.0 Pipe: 3 31.1 1.590 PL 85.00 PF 2.8 3 0.0 0.0 55.8 0.0 5.0 150 FTG 2E4L PE -1.3 4A 3.0 0.0 51.7 0.0 0.026 TL 109.00 PV Pipe: 4 31.1 1.025 PL 5.00 PF 3.3 4A 3.0 0.0 51.7 0.0 12.1 150 FTG TL PE -0.9 5 5.0 H.S. 47.6 5.0 0.218 TL 15.00 PV Pipe: 5 26.1 1.101 PL 8.00 PF 2.7 5 5.0 H.S. 47.6 5.0 8.8 150 FTG ET3RC PE -4.1 6 14.5 0.0 40.8 0.0 0.111 TL 24.00 PV Pipe: 6 26.1 0.874 PL 16.50 PF 13.2 6 14.5 0.0 40.8 0.0 14.0 150 FTG 4E2R PE -0.4 7 15.5 0.0 27.1 0.0 0.343 TL 38.50 PV Pipe: 7 16.8 0.874 PL 12.00 PF 3.3 7 15.5 0.0 27.1 0.0 9.0 150 FTG ET2R PE -4.3 8 25.5 0.0 19.5 0.0 0.152 TL 22.00 PV Pipe: 8 11.7 0.874 PL 38.00 PF 8.3 8 25.5 0.0 19.5 0.0 6.2 150 FTG 9E8T PE 0.0 9 25.5 0.0 11.2 0.0 0.077 TL 107.00 PV Pipe: 9 13.1 0.874 PL 11.50 PF 3.4 9 25.5 0.0 11.2 0.0 7.0 150 FTG 4ETR PE -0.6 9A 27.0 4.9 7.2 13.1 0.096 TL 35.50 PV Pipe: 10 -1.4 0.874 PL 7.00 PF 0.0 9 25.5 0.0 11.2 0.0 0.8 150 FTG ---- PE 0.0 10 25.5 0.0 11.2 0.0 0.002 TL 7.00 PV Pipe: 11 13.0 0.874 PL 13.50 PF 3.5 10 25.5 0.0 11.2 0.0 7.0 150 FTG 4ETR PE -0.6 bA 27.0 4.9 7.0 13.0 0.094 TL 37.50 PV Pipe: 12 -14.4 0.874 PL 17.50 PF 6.8 10 25.5 0.0 11.2 0.0 7.7 150 FTG 6E4T PE 0.2 11 25.0 0.0 18.3 0.0 0.115 TL 59.50 PV Pipe: 13 -5.1 0.874 PL 33.00 PF 1.4 11 25.0 0.0 18.3 0.0 2.7 150 FTG 9E2T PE -0.2 8 25.5 0.0 19.5 0.0 0.017 TL 84.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE 12/2)0/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -9.3 0.874 PL 10.00 PF 0.6 11 25.0 0.0 18.3 0.0 5.0 150 FTG 2R PE 4.1 12 15.5 0.0 23.0 0.0 0.051 TL 12.00 PV Pipe: 15 -9.3 0.874 PL 60.50 PF 4.0 12 15.5 0.0 23.0 0.0 5.0 150 FTG 2E3T PE 0.0 13 15.5 0.0 27.0 0.0 0.051 TL 79.50 PV Pipe: 16 0.0 0.874 PL 3.00 PF 0.0 13 15.5 0.0 27.0 0.0 0.0 150 FTG ETR PE 0.2 13A 15.0 0.0 27.3 0.0 0.000 TL 12.00 PV Pipe: 17 -9.3 0.874 PL 1.00 PF 0.1 13 15.5 0.0 27.0 0.0 5.0 150 FTG R PE 0.0 7 15.5 0.0 27.1 0.0 0.051 TL 2.00 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2019) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.088 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 14.0 ft/sec at pipe 6. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 74.39 psi with a flow of 32.50 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE 12/?)0/2020 C:\PROGRA14 FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 0.874 5.00 3.00 1.00 0.00 1.00 1.00 0.00 1.00 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE 12/2 /2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 74.40 psi Resid: 73.00 psi Flow: 500.0 gpm 80.0 1 70.0 60.0 G A U 50.0 G E 40.0 P R E 30.0 S S U 20.0 R E 10.0 LEGEND 1 Available pressure 74.39 psi 8 31.1 gpm 2 1 Required pressure 69.28 psi 8 31.1 gpm Source Supply Curve System Demand Curve P 0.0 i -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE. 12/2a0/2020 C:\PROGRAN FILES\HRS SYSTEMS\HASS87\HASS DATA\20-0329.SDF JOB TITLE: HERNANDEZ RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 84+ 77+ 0\\\\\\\\\\\\\\\\\ I * <-73.0 psi @ 500 gpm I Flow Test Point 70X 63+ P 56+ R I E I S I 5 49+ U I R I E I 42+ P I S I I 35+ 28+ 21+ 14+ LEGEND I I X = Required Water Supply 'I I 69.28 psi @ 31.1 gpm 7+ I 0 = Available Water Supply I 74.39 psi @ 31.1 gpm I, +------+--------+----- 200 300 400 500 600 700 FLOW (GPM) +-----------+ 800 900 1000 Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 r - - Bulletin 006 January 2020 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2' (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4' (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. Model RFC76 Model RFC & G5 Cover Plate Sprinkler Model Nominal K-Factor gpm/psi'/2 (I/mm/bar112) Max. Coverage Area ft x ft (m x m) Sprinkler Identification Listings & Approvals Number (SIN) RFC30 3.0(43) 14x 14(4.3x4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616 RFC49LL 4.9(71) 20x20(6.1 x6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Bottom View I Model RFC30 & RFC30LL Sprinkler Components and Dimensions I 2-5/16! (58 mm) Threads Dia. Body Cup Tower 1-3/4"(44 mm) +1- 1/4"(6 Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) II I III 4I II Deflector (extended) OKI Model G4/G5 Cover Plate 3-5/16" 84 mm) Dia 7 13/16" (5 mm) Ceiling Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the ex1 larger max. coverage area listed. Bulletin 006 Page 2 of 8 January 2020 . www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Model RFC43 & RFC43LL Sprinkler Components and Dimensions Threads - Body Cup - Tower -.-. Fusible Link - Deflector (retracted) Pin (extended) Deflector (extended) — L..... 2-5/16' (58 mm) Dia. 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Model G4/G5 Cover Plate -' - 3-5/16" (84 mm) Dia. 3/16(5 mm) Ceiling Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure (I) Max. Coverage Area 2 Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6.1 x6.1) (79) (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Ai.Iiiiig Page 3 of 8 January 2020 _______ www reliablesprinklercom r'., 4-1 ff H Bottom View - / Technical Specifications Sensitivity Style: Flat Concealed Pendent Fast-response Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Temperature Rating Max. Working Pressure: 175 psi (12 bar) Ordinary: Mm. Spacing: 8 ft. (2.4 m) 165°F (74°C) sprinkler 135°F (57°C) cover plate Material Specifications Intermediate: Thermal Sensor: Nickel Alloy Solder Link 212°F (100°C) sprinkler Sprinkler Body: Brass Alloy 165°F (74°C) cover plate Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC (without wrench-able cap) Deflector: Bronze Alloy Model W3 (with wrench-able cap) Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions I 9MW I Body Cup Towe Fusible Li Deflector (retri Pin (exter Deflector (extenc 2-5/16'(58 mm) Dia. 1-3/4' (44 mm) +1- 1/4"(6 mm) Nominal face of fitting to ceiling Model G4/G5 Cover Plate -' I 3-5/16" (84 mm) Dia. 3/16(5mm) Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure" Max. Coverage Area Ordinary Temperature __________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1 x 6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2' NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions 2-5/16 (58 mm) Dia. Threads Body Cup Tower Fusible Link 1-7/8 (48 mm) L- 3/8"(9 mm) Deflector (retracted) _______ Nominal face of fitting to ceiling Pin (extended) Deflector (extended) —-5/16"84rnmDia. Model G4/G5 Cover Plate ._3/16°(5mm) Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressuret1 Max. Coverage Area ' Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5x5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 5 of 8 January 2020 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4° NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Bottom View Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions 2-5/16"(58 mm) I Dia. Threads Body Cup Tower Fusible Link 1-7/8" (48 mm) +/- 3/8" (9 mm) Nominal face of fitting to ceiling Deflector (retracted) II _ Pin (extended) H Deflector (extended) -5/16"84mm Model G4/G5 Cover Plate Dia. .l 3/16"(5 mm) A 1 / / / /4_L Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressuret1t Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1 x6.1) (128.7) (1.4) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page Sot 8 January 2020 - - www.reliablesprinkler.com Cover Plate Finishes'1 Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Table Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) CeiIingt1 Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL G5 (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 135°F2 RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 1650F3) RFC49LL (74°C) 135°F2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 G5 (84) (67) (1 g) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x /2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4° thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 130. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com n Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 ONPage 8 of 8 January 2020 www.reIiablesprinkler.com Bulletin 135 October 2019 Relmlabld Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The Fl Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where per by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mml mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler K-Factor Thread Size Max. Coverage Area Model Identification Orientation gpm/psi112 NPTorISO7-1 Installation Options ftxft(mxm) Number (SIN) (lpm/bar1 ) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x 16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20x20(6.1 x6.1) FiRes76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or 14 x 14(4.3 x 4.3) Recessed F1Res49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res76 CCP R7618 Pendent 7.6(109) 3'4 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablespririkler.com ')1M" 17rr,n. Face of titling to finished ceiling 1/2 (13mm) +1- 1/4 (6mm) Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2' NPTor 1507-1R1/2 Nominal K-Factor: 3.0 (43 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F(68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* 4 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches 40 Deflector: Bronze Alloy Model W2 I Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Threads Wrench Flat Sealing Assembly 2-1/4' Glass Bulb (57mm)1 I II I I Load Screw Deflector ....1° . k32rnm) Components Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Area ) Flow gpm (I/mm) ft. x ft.(m x m) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 8(30) 7.0(0.48) 1104 inches (2510100mm) 14 x 14(4.3 x 4.3) 10(38) 11.0(0.76) 15 x 15 (4.6 x 4.6) 12(45) 16.0(1.1) 16x16 (4.9x4.9) 13(49) 18.8(1.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2 of 15 October 2019 - www.reliablesprinkler.com Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2 NPTor lS07-1R1/2 Temperature Ratings Nominal K-Factor: 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions 11TT' 2-1/4" (57mm) 2-1/4" (57mm) 4 —(49 Face of fitting DIA. r Face of fitting 1-15/16" to finished ceiling to finishe d(49mm) DIA. ceiting 1/2" (13mm) 5/8"(l6mml3/8"(9mm) +/- 1/4"(6mm) NONE 'I 03M 2-1/4 (57) 1-3/4" (44mm)i 5/8 (41mm) ~1- 6mm1 "(9mm) (32mm) 2718 (72mm) DlA. - 3/8 L2718 (72mm) DIA. 1/4" Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemstht Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 13(49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16(4.9 x 4.9) 13(49) 7.0(0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6. 1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15(57) 9.4(0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 lRellabld Page 3 of 15 October 2019 www.reliablesprinkler.com to finished ceiling 5/8° (16mm) +1- 3/8(9mm) Fl Recessed Escutcheon Installation Dimensions Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2 NPTor 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4° (57mm) 2-1/4° (57mm) hr DIA. -ii F'.p of fitting hT- DIA. -ii FP of fittinn 1-15/16° to finished (49mm) DIA. ceiling 1/2°(l3mm) I +1- 1/4° (6mm) L_ .._J 1-3/4"(44rnrn) 2-7/8° (72mm) DIA. F2 & FV Recessed Escutcheon Installation Model Fl Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems0t Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20x20(6.1 x6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin Bulletin 135 Page 4 of 15 October 2019 Heliabidd -. www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Threads 3/4 NPT or 1S07 1 R3/4 Temperature Ratings Nominal K-Factor: 7.6(109 metric) 155°F (68°C) 0 Max. Working Pressure: 175 psi (12 bar) 175°F (79°c) Material Specifications . jC Recessed Escutcheons :, Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Fl Recessed 51 F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions Face of fitting to finished ceiling 5I8 (16mm) +1- 3I8 (9mm) 2-1/4 (57mm) DIA, 1-15/16 (49mm) DIA. Face of fitting to finished ceiling 1/2 (13mm) +1- 1/4(6mm) 1-5/8 (44mm) 1-518°(4lmm) 4-/- 3/8 (9mm) Qk 2-7/8 (72mm) 1-3/4 (44mm) +1- 1/4(6mm) Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems1" Maximum Coverage Aream Flow Pressure Deflector to ft. x ft. (m x m) gpm (I/mm) - psi (bar) Ceiling Distance 18 x 18(5.5 x 5.5) 21 (80) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 20x20(6.1 x6.1) 23(87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Beliabl!Page Sot 15 October 2019 - - 0 - www.reliablesprinkter.com Technical Spécifióations Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2 NPTor 1S07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy rInusnes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)° FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not listed for use in positively pressurized ceiling plenums. Model F1Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions TIT71. 2-5/8° (67mm) 2-5/8° (67mm) DIA. DIA. 25/160 2-5/16" T (59mm)DIA.j (59mm)DIA. ace of filling to finished ceiling 1/4° (32mm) - 1/4° (6mm) 15/16" 24mm) L3-3/16"(78mm) Face of fitting to finished ceiling 1-1/4° (32mm) +1- 1/4°(6mm) 1°(25mm) +1- 1/4" (6mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Modal F1Rasfl incip Panriant & FP Ra,ad Pndnt Anriniciar I.1urIri,Ii, flnn Critri Minimum Flow and Residual Pressure in Wet Pipe SystemsOl Maximum Coverage Area Flow Pressure I Deflector to Ceiling Distance ft. x ft. (m x m) gpm (I/mm) psi (bar) 12 x 12 (3.7 x 3.7) 8 (30) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14(4.3 x 4.3) 11(38) 13.4(0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 iiai Page 6 of 15 October 2019 www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2 NPTor 1S07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 m glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 05105TT 2-5/8° (67mm) DIA. 2-5/16° (59mm)DIA. ace of fitting to finished ceiling I it I ______________________________ ______________________________ Faceof fitting to finished I ceiling I -1/4° (32mm) 1-1 /4°(32mm) I- 1/4°(6mm) i-,- 1/4° (6mm) (24mm) - . L3-3/16"(78mm) DIA. FP Recessed Escutcheon Installation Model Fl Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems" Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (Vmin) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16.7(1.15) 16 X 16(4.9 X 4.9) 14(53) 8.2(0.57) 18 x 18(5.5 x 5.5) 18(68) 13.5(0.93) 20 x 20 (6.1 x 6. 1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 7 of 15 October 2019 . - www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendant and Recessed Pendent Threads: 1/2' NPTor lS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PIFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 1l1T7' 2-5/16" (59mm)DIA. ace of fitting to finished ceiling I ____________________________________ Face of fitting to finished ceiling I -1I4(32mm) (-1/4°(6mm) , [ I 1-1/4(32mm) __________ 1/4 (6mm) (24mm) ... .+/-1/4(6rnrn) L3-3/16"(78mm) DIA. FP Recessed Escutcheon Installation Model Fl Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems() Maximum Coverage AreaR ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page B of 15 October 2019 -. www.reiiablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4" NPT or 1S07-1 R3/4 Nominal K-Factor: 7.6(109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8° (67mm) DIA. 2-5/16° (59mm)DIA. ceof fitting 0 finished ceiling -- 1 ' I _______________________________ Face of fitting to finished ceiling IIIi ..I /4° (32mm) I I 1-1/4°(32mm) 1/4°(6mm) 1/4° (6mm) , 24mm) - . - \rV +/1/4°(6rnm) L3-3/18"(78mm) DIA. - FPRecessedEscutcheonInstallation Model Fl Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure In Wet Pipe Systems") Maximum Coverage Aream Flow Pressure Deflector to Ceiling Distance ft. x ft. (mx m) gpm (1/mm) psi (bar) 16 x 16(4.9 x 4.9) 21(80) 7.6(0.52) 1/2 to 1 inch (13 to 25 mm) 10.8 (0.75) 18 x 18(5.5 x 5.5) 22(83) 8.4(0.58) 20 x 20(6.1 x 6.1) 25(95) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 9 of 15 October 2019 - - www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPT or 1507-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model Fl Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41 mm) 3/8" (10mm) +1- 1/4" (6mm) +1- 1/4° (6mm) - 2-7/16" (62mm)- - 1? 5;16J (8mm) 21/40 1-15/16° (57mm) (49mm) - DIA. DIA. Top of Deflector Down from - Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV RecessedEscutcheon Installation Model FlRes44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (1/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 12(45) 7.5(0.52) 4 to 6 inches (100 to 150 mm) 18.7(1.29) 14 x 14(4.3 x 4.3) 14 (53) 10.2(0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 16 x 16(4.9 x 4.9) 16(61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20(4.9 x 6.1) 23(87) 27.4(l.89) 18 x 18(5.5 x 5.5) 19(72) 12 x 12(3.7 x 3.7) 14 (53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 27.4(l.89) 14 x 14(4.3 x 4.3) 16(61) 13.2(0.91) 15 X 15(4.6 x 4.6) 16(61) 13.2(0.91) 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) 16 x 18(4.9 x 5.5) 20(76) 20.7(l.43) 16 x 20(4.9 x 6.1) 23(87) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 100115 October 2019 - www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2 NPTor ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PIFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) (1) Cover Plates SWC Conical Concealed Plate(2) SWC-2 (Slotted) Conical Concealed Plate131 Sprinkler Wrenches Model GFR2 Note: "Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. 21135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers 131135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1'(25mm) 1"25mm +1- 1/4 (6mm) +1- 1I4 (6mm) Face of fitting to finished wait I - -2-7/16 )62mm)--. 5Il6 J (8mm) Dimensions - -- !1 il - 15/8, (41mm) swc & SWC-2 Concealed Cover Plate Installation Top of Deflector Down from Ceiling lobe Either 4 to 6 (100mm to (84mm) 150mm) or 6to 12 DIA. (150mm to 300mm) I Based on Hydraulic I Calculations I Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst') Maximum Coverage Area(2) ft. x ft. (m x ni) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (I/mm) Pressure psi (bar) Flow gpni (I/mm) Pressure 12 x 12(3.7 x 3.7) 13(49) 8.7 (0.60) 14(53) 10.2 (0.7) 14 x 14 (4,3 x 4.3) 14(53) 10.2(0.7) 14(53) 10.2 (0.7) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) - - - - 4 to 6 inches 16 x 16 (4.9 x 4.9) 17(64) 15.0(1.03) -- -- (100 to 150 mm) 16 x 18(5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20(4.9x 6.1) 23(87) 27.4(l.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) - - -- 14 x 14(4.3 x 4.3) 15(57) 11.7(0.81) - - 15 x 15 (4.6 x 4.6) 17 (64) ' 15.0(1.03) - - - - 6 t 12 inches (150 to 300 mm) 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- 16x 18 (4.9x5.5) 20(76) 20.7(1.43) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger niax. coverage area listed. Bulletin 135 Page 11 of 15 October 2019 Rellabld www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2 NPTor IS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8° (41mm) 3/8°(lomm) +1- 1/4° (6mm) +/- 1/4° (6mm) —2-7/16 (62mm)---.-J 5/16° (8mm) Dimensions 1-15/16° i 1 Jk F2 & FV Recessed Escutcheon Installation Top of Deflector Down from Ceiling to be Either 4° to 6° (100 to 150 mm) or 6 to 12° (150 to 300 mm) Based on Hydraulic Calculations Model Fl Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage ArearA ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6(0.52) 4 to 6 inches (100 to 150 mm) 25.0 (1.72) 14 x 14 (4.3 x 4.3) 18(68) 9.7 (0.66) 15 x 15(4.6 X 4.6) 19(72) 10.7 (0.74) 16 x 16(4.9 x 4.9) 21(80) 13.2(0.91) 16 x 18(5.5 x 5.5) 25(95) 18.6(l.28) 16 x 20(4.9 x 6.1) 29(110) 12 x 12(3.7 x 3.7) 22(83) 14.4(l.0) 6 to 12 inches (150to300mm) 28.6(l.97) 14 x 14(4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15 (4.6 x 4.6) 24(91) 17.1 (1.18) 16x 16(4.9x4,9) 26(98) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 31(117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 12 of 15 October 2019 - www.reliablesprinkler.com Finishes Technical Specifications (See Table N) Style: Sidewall and Recessed Sidewall Threads: 1/2 NPT or 1507-1R1/2 Temperature Ratings Nominal K-Factor: 5.8 (84 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F(79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb F2 Recessed Sprinkler Frame: Brass Alloy FV Recessed Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model GFR2 (Recessed) Model Fl Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions 2-7/8°(73mm) - 5/16 (8mm) Dimensions Face of titling to finished wall 1-7/8° (48mm) 3/8°(10mm) +1- 1/4"(6mm) +/- 1/4° (6mm) 2-1/4° 1-15/16° jj I jJ (5f F2&FV Recessed Escutcheon Installation Top of Deflector Down From Ceiling to be Either 4° 106° (100 to 150 mm) or 6 to 12 (15010300mm) Based on Hydraulic Calculations Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems11 Maximum Coverage Area2 ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18x20(5.5x6,1) 30(114) 26.8(1.85) 4 to 6 inches (100 150rn) 52.4(3.63) 20 x 20(6.1 x 6.1) 30(114) 26.8(1.85) 16 x 22(4.9 x 6.7) 33(125) 32.4(2.23) 16 x 24(4.9 x 7.3) 38(144) 42.9(2.96) 14 x 26(4.3 x 7.9) 42(160) 18 x 20 (5.5 x 6.1) 35(133) 36.4(2.51) 610 12 inches (15010300mm) 62.9(4.34) 16 x 22 (4.9 x 6.7) 38(144) 42.9 (2.96) 16 x 24(4.9 x 7.3) 42(160) 52.4 (3.61) 14 x 26(4.3 x 7.9) 46(174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 13 of 15 October 2019 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler'" Fl, F2. FV, FP'3t, CCP, SWC (Conical) Sprinkler (1) Fl, F2. FV, FP'', CCP, SWC (Conical) Escutcheons Cover Plates (1) Escutcheons Cover Plates (1) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester(2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- -- -- PTFE'2' -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model W2 Model GFR2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1S07-1R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and 1507-1R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model Fl Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 Page 14 of 15 October 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee s For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or 507-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) z Bulletin 135 Page 15 of 15 October 2019 www.reliabIesprinkler.com Pendent I Horizontal Sidewall Model Fl FR Series Quick Response Glass Bulb Sprinklers Recessed Pendent/FP It I XLH Recessed Pendent F1 /F2 XLH Upright XLH Pendent Bulletin 014 March 2019 Re.1 a,bk Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model El FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS SchadenverhUtung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1 425), 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Model Fl FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. 40 Model El FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model Fl FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model Fl FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model El FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1ER Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model El ER Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1 FIR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model El ER Series Recessed sprinklers are to be installed as shown in Fig. 1 Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model El FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model El ER Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model E1FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed, The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model FlEA Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model El FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GF1R2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model E1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-f actor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height _____ Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA 1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1414 cULus FM, , LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 12,3,4 Concealed Pendent 2.25 57 GFR2 RA14141 cULus,VdS,EC 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA14151 cULus, ULH Concealed Pendent 2.25 57 GFR2 RA14151 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FRS6 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PIFE plating. (31 Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the Fl FR56 concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model Fl FR56 Concealed Pendent and Model Fl FR56LL concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the Fl FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies Only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the Fl FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector! Orientation Ordinary Temp. Classification 100°F (38°C) Max.Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1070C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) I Temp. Rating 175°F (79°C) 1 Temp. Rating I 200°F (93°C) I Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I Upright cULus FIFR4O Pendent VdS Recessed Pendent VdS I Pendent cULus Fl FR42 Recessed Pendent cULus I Upright cULus F1FR42LL Pendent I cULus, ULH I Recessed Pendent I cULus, ULH Pendent cULus Fl FRXLH Recessed Pendent cULus I Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC I FIFRS6 Concealed Pendent* cULus cULus,VdS,EC I cULus Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent I cULus, ULH I F1FR56LL Recessed Pendent I cULus, ULH Concealed Pendent* I cULus, ULH I Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM I I F1FRS6 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 1650F (740C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector! Model Fl Model F2 Model FP Model Orientation (Fig. 1 & 3) (Fig. I & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment FIFR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus FM LPCB, cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FRS6 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. J T AT MAXIMUM RECESS = 7/8"[22.2mm] (3.2mm] I / AT MINIMUM RECESS = 1-5/8 "[41.3mm] F2 ESCUTCHEON I AT MAXIMUM RECESS = 1- 1/8"[28. 6mm] AT MINIMUM RECESS A A Ft ESCUTCHEON 2 1/4" HOLE 014. (57.2mm] I 75/16" 014 [49.2mm] 11 -------- - Ii ( \ / /—o TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS __\\\\ Fl ESCUTCHEON_L. 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT f 1 X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F! ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] ____ AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[l9mm] -7777771 I AT MINIMUM RECESS = 3/8"[9.5mm] 2 27/32" 014. [72.2mm] Model F1F1R56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 2 5/8' DI 66.7mm 1" X 1/2" REDUCER HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP EMJ CEILING AT MINIMUM RECESS FACE OF FITTING - TO FACE OF CEILING DIMENSION L I I AT MAXIMUM RECESS = 1-1/2738mm] AT MAXIMUM RECESS = 9/16"[14.3mm] Y2 "[12.7mm] AT MINIMUM RECESS = 1 "[25.4mm] ADJUSTMENT __________ 31/4"DIA. [82.6mm] Model F1FOR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. Fl ESCUTCHEON L.4 AT & IA %/iIIII&I nerrer - 4 7 Jo "r. n__ IiI IWPtAIIW(JM C&.C..) = I .'/O L..)?.mmJ AT MINIMUM RECESS = 2-1/16 r52. 4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] '-1/8" AT MINIMUM RECESS = 2- 1/16"[52.4mm] [3.2mm] V (j) 4"-12" 32" DIA. CEILING TO [72.2mm] DEFLECTOR Fl ESCUTCHEON -H 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 [25.4mm] AT MINIMUM RECESS = 3/89.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4 "[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE 0/A. [57.2mm] 1" X 1/2" REDUCER I ilIIlI 1 15/16" DIA. 4jJ4 [49.2mm] lull 11111 I -- TURN COLLAR UNTIL -, TIGHT AGAINST SPRINKLER WRENCH BOSS. RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler Wth Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW TT l - 25/8 DIA. .1 HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 1/2" MAX. .. COVER ADJUSTMENT COVER PLATE ASSEMBLY _____/ 5/16" DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT Ftg.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment- Model COP cover plate 2 5/16" DIA - u CUP CEILING 15/16" 017FG01A 1" x 1/2" REDUCING TEE OR ELBOW —FE__ ____ 25/8 0/A. 2 5/16" 0/A - 1' .'PHOLE IN CEILING CUP —. M vu 1 1/2k' MAX. TT —4tJH--- FACE OF FITTING II [ To FACE OF CEILING kktt )I FT DIMENSION CEILING—" MY -F-- '- I 5/16" MAX. J 3/4" COVER ADJUSTMENT COVER PLATE— I ASSEMBLY • 3 5/16" 0/A SPRINKLER CONCEALED, 5Z16" ADJUSTMENT 017FG0 Hg. 5- Model Fl FR56IF1 FR56LL Concealed Pendent spnnkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover pIate1 Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (X5X) White Painted Specpl Application Finishes Sprinkler Escutcheon Cover plate111 Electroless Nickel PTFEI7I Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint121161 Black Paint Off White Off White 21161 Off White Satin Chrome Chrome Dull I Chrome Dull I Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. 2) cULus Listed only. (3) 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(vSw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][F1 FR421 [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright] [Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R112] Sprinkler Temperature Rating: [135°F (570C)][155°F (680C)][175°F (790C)][200°F (930C)][286°F (1410C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment] [low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper Reliabid (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300