Loading...
HomeMy WebLinkAbout6010 HIDDEN VALLEY RD; 210; FPC2017-0214; PermitPERMIT REPORT (bty of Carlsbad Print Date: 10/14/2021 Job Address: 1 6010 HIDDEN VALLEY RD, # 210, CARLSBAD, CA 92011-4219 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120406800 Track #: Valuation: $166,071.52 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: PACIFIC ENT- FIRE ALARM TI Applicant: RED HAWK FIRE & SECURITY JOHN STASUKEVICH 920 S ANDREASEN DR, # 102 ESCONDIDO, CA 92029-1936 (760) 535-0045 Permit No: FPC2017-0214 Status: Closed - Finaled Applied: 08/02/2017 Issued: 08/16/2017 Finaled Close Out: 08/12/2021 Inspector: Final Inspection: FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 . Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM TENANT IMPROVEMENT SUBMITTAL For PACIFIC ENT NORTH COAST MEDICAL PLAZA 6010 HIDDEN VALLEY ROAD, SUITE 210, CARLSBAD, CA 92011 FPC20I7-0214 6010 HIDDEN VALLEY RD UNIT2IO - ubiffid y: FILE Copy Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 40\ PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 CONTRACTORS LICENSE: C-10/C-16 #713099,11/30/17 PROJECT MANAGER: John Stasukevich PROJECT NAME: PACIFIC ENT NORTH COAST MEDICAL PLAZA PROJECT ADDRESS: 6010 HIDDEN VALLEY ROAD, SUITE 210, CARLSBAD, CA 92011 SCOPE OF WORK: FIRE ALARM SYSTEM TENANT IMPROVEMENT July 31, 2017 Re: Pacific Ent North Coast Medical Plaza 6010 Hidden Valley Road, Suite 210, Carlsbad, CA 92011 Fire Alarm System - Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinklered. OTY. MODEL NO. DESCRIPTION C.S.F.M. 1 BPS 10A Existing Booster Power Supply 7300-1657:0229 13 GCF-VM Multi Candela Strobe, Ceiling Mount 7125-1657:0219 4 GCF-HDVM Multi Candela Horn Strobe, Ceiling Mount 7125-1657:0202 Notes: 1. The new Booster Power Supply is manufactured by EST and is compatible with all new devices. Respectfully Submitted, RED HAWK FIRE & SECURITY [] 0 EDWARDS Catalog 1> Power Supplies and Accessories LIFE SAFETY INCIDENT MANAGEMENT Remote Booster Power Supplies BPS6A, B1@A Overview The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition (lJO)OFire Alarm Systems UL636 (ANET, UEHX7) Holdup Pjarni units and Systems UL609 OD(, AOTX7) Local Burglar Alarm units and Systems uL294 (ALW, UEHX7) Access control systems UL365 (APAW, APAW7) Police Station connected Burglar Alarm units and Systems uL1076 (APOu, APOU7) Proprietary Burglar Alarm System units UL1610 (AMC)) central Station Alarm unit uLc-s527 (OOC) control units, Fire Alarm (Canada) uLc-S303 AOT(7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) ccs MEA 476-91-E Vol. 13 H1H;pj11'i II,,,1 S3424 7300-1657. 0229 Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identity wing or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire Sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 • The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. Page 1 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue I a, Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. BPS NACs can be configured for a 3-3-3 temporal or continuous output. California temporal rate outputs are also available on cer- tain models. This makes the BPS ideal for applications requiring signaling rates that are not available from the main system. Dimensions H Top V 0 01 View L Dl D2 D3 D4 D5 06 ] 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere- hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Power-limited wiring area S Route AC supply through these knockouts only (Nonpower-limited and supervised) Multiple 001 (5) modules using the BPS's sense inputs B1 ° Notification appliance circuit (NAG) T NAG1/ UL listed AUX1 EOL 15 KW NAG2/ AUX2 Notification appliance circuit (NAG) NAG3/ + UL listed AUX3 EOL 15 KW NAG4/ AUX4 200 mAAUX - Continuous IN Sense 1 COM LJ 1- I1_ IN _______ Sense 2 COM OUT -EOL 47K II NO -11+ Trouble COM V 10111 I NCN 109 T132 II GG1(5) module 0 II Data out to II 00 18765 4321 next device Ikvcixr LFM GG1(S) module CC - Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the booster's terminals. This allows multiple boosters to be driven from a single NAC circuit without the need for special configurations. NAC Circuit I > To next signaling NAC Circuit device, booster, or EOL resistor ()) I CD CD ) NAG output #1 Fire Alarm I 0 (A ) NAG output #2 Control Panel CD ) NAC output #3 ) NAG output #4 C C Booster Power Configuring the Booster for AC Power Fail delay operation* 0 TB1 Notification appliance circuit (NAG) NAC 1/+ - UL listed AUX 1 - - EOL 15 kO NAC2/ + AUX2 - Notification appliance circuit (NAG) UL listed NAG3/ + - AUX3 - - EOL 15 kO NAG4/ + AUX4 - 200 mAAuX Continuous IN Sense 1 COME OUT IN ___________ V10IMM E Sense 2 COM L )EOL47 kO Ii 109 OUTf . GG1(S) module [1][3] NO 00 :h Trouble GOM t 8 7 6 5 4 3 2 1 NCt __ IDwwtsI Komi!_ • S Data in from Gil previous device moul[4) or Signature 2 controller [3] *The Booster supports AG Power fail delay Data in from previous Data out to of three hours via its trouble contact when device or Signature next device controller dip switch SW2-6 is on. All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS TB1 24V fNAC3/ /+- I + / _nwi 12 V Security Security EOL ~dev~jc~e:hq =device = device To next device or end 9 [1] Disable the BPS's ground fault jumper (JP3) Page 3 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 A 0 A N) N) 0) C) () 0 >>. 0) CY1 (DC 0 > 3,: 33 o 00 3: C 3 CD C/) N CD CD 0 CD 3 5. a co 0 0. C) cn CD 05 Q(D 5.00 0 (C)0 63 -h 9) 0)0 Cl) co 5 040 -, 0 0 0 C.)J C (DC/C CC) CD 0) () -' CC = C 0 CD CD CD -: 3 03 z 3, 0) 0 CD 0z CD C CD m 0 C C) 0 CL (D N) 0 05. 00 Ba >0 (DO 00 00 CD 0.> 00 ) C.) CD CD 5.0) 00 N) o C DC 0) ,21 0) CD (DC DC (DC (DC 3 al CO CO CO CO CO O - : aJ CO0 co zc C/) O) C/) C/) C/) C/) 3 0)0)0)0) - 0 co =0 D m c) 3° m go) a 0 10 30) a 3 - 0 CL OR CL I. OL DC to C) Im 3 . CD 5 < 5 (DC. I]J CD C) 0 ., 0 C) IDI .3 0 3 m Iwl S p z-C ID 9 ca DC C) C..) - Cl 3 0) 0 si ) 5• w CD .CD3• a 3 CD <C)'< ---'WW coC.)--- COW c)ç) 00 N)- Cl)2 m0>0 00 3,>> 'OcC>o10. m 0 41 0 - p.CO 0) 0) 0 CCC CD Q) 0 0 0 DDD'' _0 ' COW 00 00 cc) COWaa W;CO W -00 00 CD CD CD '0 L CD CD 00 Q g CD Cl) Cl) °00_L. w - o cc 00 66340 CD Z 3 3 co - o CDCCCCDCDCD00 0 o CD' N) o C- CDCDCDCDCD -.--. a CD0 DDDDDWW 000000)0) -'DC -D - CD -' CD CD CD 0 CD 3 N)r CD CD CD m 0 co cn .3 0 Q —Q - cm C.)I C.)I . . . 91.-LI.-OL EDWARDS Catalog Strobes, Horns, Bells, Chimes min United Techn ologies LIFE SAFETY INCIDENT MANAGEMENT Field Configurable T..~ Ceiling Strobes J N One or more patents pending. ri <~> KC X '~-" II IVIEA ( ( 7125-1657: 0219 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FulILight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullUght technology go well beyond the minimum UL-required cross' pattern, significantly exceeding UL-1 971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4' square electrical box, 21/" (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8"dia. (173 mm) 10" (25 mm) O.6O15!) Light output (effective cd) Percent of UL rating versus angle Percentage of rated output - 0• - Angle— Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output / Candela switch (see ordering information). The output / ,.- setting is changed by simply opening the a device and sliding the switch to the desired / setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WAR NING:These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 90 .5. S M _______ appliance, fire alarm ______I end-of-line control To listed 11Jl cJ To next panel HHcnLjI or return to + I control I equipment Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 S Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. UL Rating Light output setting, standard models 11151,or "D" or or "B" or 1 I RMS RMS RMS RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 [Current't pical Light output setting, standard models 'J5" or "D" "30" or "C""75" or "B" "95" or "A" RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 9VV'dc 6@ 90 168 194 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Light output setting, high output models r"95"or$'D$l or or "B" I77 or "A" RMS RMS RMS RMS 330 392 502 565 432 518 643 693 Light output setting, high output models u95 or "D" or or "B" or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current values are shown in mA. Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 Cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc RNR. GC-VM series strobes: one flash per second synchronized with optional Cl M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1S, SlGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, i064, i0500, Fireshield Plus 3, 5 and 10 zone. Add Cl M for G1-CVM &G1 -HDVM devices only. S Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Ordering Information EDAIARDS Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. LIFE SAFETY & INCIDENT MANAGEMENT FM —ode l 'I Housing Markingi —Lin Strobe -§-h -ip—Wt-. S Life safety ADoliances (c/w runnino man icon screen orinted on housinal GC-VM White None Clear Selectable 15, 30, 75, or 95 cd 1.8 lb. (0.82 kg.) White "FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 cd GCF-VMH White "FIRE" ECS/MNS Anoliances (no runnina man icon on housina GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output A, B, C or 0 Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWI'J-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. h t7 Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. ERT Page 4of4 DATA SHEET E850010557 Not to be used for installation purposes. Issue 1 fl EDWARDS Catalog P Strobes, Horns, Bells, Chimes MWIA"I =I United Technologies LIFE SAFETY INCIDENT MANAGEMENT Field Configurable - One or more patents pending Ceiling Horn -oiiuue (,.. &eRe-sis: MEA CE 7300-1657: 0202 S218 Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required 'cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 o 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971 -listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low d8 output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 d above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. NJ Polarity shown in alarm condition To next appliance, end-of-line or return to control equipment Note: Strobes must have continuous voltage. Dimensions ( ) 1 (25rm " m) 1.0 0.60"(15 mm) Page 2 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 S Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting UL 15 c 30J 75J • 95cd' r95cd 115 c 150d 177d Rating RMS RMS RMS RMS 1 I RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting Typical I&rcd 3od 75 c 95cd] [ 95 c 115 Cd 150 Cd 177 cd] Current RMS Mean RMS Mn RMS Mean RMS Mean J I RMS Mean RMS Mean RMS Mean RMS Mean I 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 4do 80 c'J1 108 10t' 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVM Temporal Horn-strobe: Low dB Setting GC-HDVMH High Cd Temporal Horn-strobe: Low dB Setting [Typical 15 c 30 c 75 c 95cd1 r95 c 115 c 150 c 177cd1 I Current RMS Mean RMS Mean RMS Mean RMS Mean I I RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 .33Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery Al-I calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output UL464 Average Peak High dB Setting Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 95.7 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 33 Vdc 78 83 88.8 92.4 80.9 85.9 91,8 95,1 Notes 1. All values shown are dBA measured at 10 feet (3.01m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 Light output - (effective cd) Percent of UL rating versus angle P,Cs1olLtRaIhc DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 so. LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fireIfs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white modals available. Lens Optical grade polycarbonate (clear) Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-5526, year 2004 UL Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal outout of horns on same circuit OA GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) 1/2 sec ON, 1/2 sec OFF, 1/2 sec ON, ½sec OFF, ½ sec ON, l½sec Temporal audible pattern OFF, then repeat cycle Ordering Information Ship Number Color Wt. lbs Catalog Housing Marking Description (kg) (3U-HUVM White None IUM1.. White "FIRE" Genesis Ceiling/Wall Horn-Strobe with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red "FIRE" (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95,115, 150,0r177cd output [Accessories Gi M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 SIGA-CC1 S Intelligent Synchronization Output Module (2-gang) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 STATE FIRE MARSHAL LISTING SHEETS S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 0i65.702'29 . Page 1 of 1 CATEGORY: 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models BPS6A, t()A BP56N230, 13PS10A/230, BPS6CAA, and BPS10CM remote booster power supplies. *Models APS6A, AP56A1230, APS6CAA, APS10A, and APS10A/230 Auxiliary Power Supply. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:229 S 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM, C1V4v1, GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 40 LISTING SERVICE C LISTING No. 75'7:0202 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST" G1-HV15, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GlRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, G'CF11DVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1 R-HDV1575, G1F-HDV1575, and G1RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33VdcNfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1R-HDV1575, GI F-HDV1575, G1 RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd . 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, G1 F-HDV1575, Gi RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC:HDvMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division