HomeMy WebLinkAbout6021 INNOVATION WAY; 110; FPC2019-0006; PermitPERMIT REPORT
(bty of
Carlsbad
Print Date: 10/20/2021
Job Address: 6021 INNOVATION WAY, # 110, CARLSBAD, CA 92009
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2132611400 Track #:
Valuation: $350,168.50 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check U:
Project Title:
Description: EUREKA -SPRINKLER TI (41 HEADS)
Applicant:
INDUSTRIAL FIRE SPRINKLER CO
STEVE SCOTT
3845 IMPERIAL AVE
SAN DIEGO, CA 92113-1702
(619) 266-6030 x107
Permit No: FPC2019-0006
Status: Closed - Finaled
Applied: 01/16/2019
Issued: 01/28/2019
Finaled Close Out: 08/14/2019
Inspector:
Final Inspection:
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00
-
Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
C_~Jolcl_o
tqca® Worldwide I Contacts www.tyco-fire.com
Series DS-1 - 5.6 K-factor, Dry-type Sprinklers
Pendent, Upright, and Horizontal Sidewall
Standard Response, Standard Coverage
General
Description
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response (5 mm bulb), Standard
Coverage Dry-type Sprinklers are dec-
orative glass bulb autamatic sprinklers
typically used where:
pendent sprinklers are required on
dry pipe systems that are exposed
to freezing temperatures (e.g., sprin-
kler drops from unheated portions of
buildings)
sprinklers and/or a portion of the
connecting piping may be exposed
to freezing temperatures (e.g., sprin-
kler drops from wet systems into
freezers, sprinkler sprigs from wet
systems into unheated attics, or hor-
izontal piping extensions through a
wall to protect unheated areas of a
building such as loading docks, over-
hangs, and building exteriors)
sprinklers are used on systems that
are seasonably drained to avoid
freezing (e.g., vacation resort areas)
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP 700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 10
NOTICE
Series DS-1 Dry-type Sprinklers
described herein must be installed
and maintained in compliance with this
document, as well as with the applica-
ble standards of the NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA),
in addition to the standards of any other
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Series DS-1 Dry-type Sprinklers must
only be installed in fittings that meet
the requirements of the Design Crite-
ria section.
Sprinkler
Identification
Numbers (SINs)
TY3255 - Pendent
TY3155 - Upright
TY3355 - Horizontal Sidewall
Technical
Data
Approvals
UL and C-UL Listed
FM Approved
VdS Approved TY3255 w/Standard Escutcheon only
NYC Approved
under MEA 352-01-F LPCB Approved
Reference No. 094a/11
CE Certified
Certificate of Conformity No. 0832-CPD-2015
(Refer to Tables A and B for details.)
AUGUST 2018
Maximum Working Pressure
175 psi (12,1 bar)
Inlet Thread Connections
1 inch NPT
ISO 7-R 1
Discharge Coefficient
K=5.6 gpm/p5i1/2 (80,6 1pm/bar112)
Temperature Ratings
Refer to Tables A and B.
Finishes
Sprinkler: Refer to Table D.
Escutcheon: Refer to Table D.
Physical Characteristics
Inlet .............................Copper
Plug .............................Copper
Yoke ......
...
.
.............
Stainless Steel
Casing .............Galvanized Carbon Steel
Insert. ............................Bronze
Bulb Seat...................Stainless Steel
Bulb (5 mm dia.) .....................Glass
Compression Screw .................Bronze
Deflector ..........................Bronze
Frame ............................Bronze
Guide Tube .................Stainless Steel
Water Tube .................Stainless Steel
Spring .....................Stainless Steel
Sealing Assembly. . Beryllium Nickel w/TEFLON
Escutcheon ...................Carbon Steel
TFP500
TFP500
Page 2 of 10
SPRINKLER
TYPE
ESCUTCHEON
TYPE
TEMPERATURE
RATING
BULB
COLOR CODE
SPRINKLER FINISH
NATURAL CHROME
BRASS PLATED POLYESTER*
PENDENT
(TY3255)
STANDARD
135°F (57°C) Orange
1,2,3,4,5,6 1,2,4,5,6
155°F (68°C) Red
175-F (79-C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6
RECESSED
135°F (57°C) Orange
1,2,3,5 1,2,5
155°F (68°C) Red
175°F (79°C) Yellow
200-F (93-C) Green
286°F (141°C) Blue 1,2
360°F (182°C) Mauve N/A
DEEP
135°F (57°C) Orange
1,2,3,4,5 1,2,4,5
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F(182°C) Mauve
WITHOUT
135°F (57°C) Orange
155°F(68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve 1, 2, 3 1,2
UPRIGHT
(TY3155) WITHOUT
135°F (57°C) Orange
1, 2, 3, 4, 5 1, 2, 4, 5
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve 1,2, 3 1,2
Notes:
Listed by underwriters Laboratories, Inc. (UL), maximum order length of 48 inches
Listed by underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches
Approved by FM Global IFM Approvals), maximum order length of 48 inches
Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only
Approved by the City of New York under MEA 352-01-E
Approved by VdS
Frame and deflector only
N/A - Not Applicable
TABLE A
SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE
LABORATORY LISTINGS AND APPROVALS
TFP500
Page 3 of 10
SPRINKLER ESCUTCHEON TEMPERATURE BULB SPRINKLER FINISH
NATURAL
BRASS
CHROME
PLATED POLYESTER*** TYPE TYPE RATING COLOR CODE
135°F (57°C) Orange
155-F (68-C) Red
STANDARD 175°F(79°C) Yellow
200°F(93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve
135°F (57°C) Orange
155°F(68°C) Red
175°F (79°C) Yellow HSW*
(TY3355) DEEP 1 2°°, 3***, 4, 5 1 2°, 4 5
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve
135°F (57°C) Orange
155°F(68°C) Red
175°F (79°C) Yellow WITHOUT
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve 2°, 5 1', 2**
Notes:
Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches
Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches
Approved by FM Global (FM Approvals), maximum order length of 48 inches
Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only
Approved by the City of New York under MEA 352-01-E
Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm)
Light and ordinary hazard occupancies only
Light hazard occupancies only
Frame and deflector only
TABLE B
SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE
LABORATORY LISTINGS AND APPROVALS
PLUG WITH INLET
SEALING
ASSEMBLY
YOKE
SPRING INLET
BAND
WATER
II II
TUBE CASING
GUIDE - INSERT
TUBE
BULB
FRAME -'/ SEAT ',
5 mm BULB VENT HOLE _____
COMPRESSION
DEFLECTOR SCREW
FIGURE 1
SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE
ASSEMBLY
-
WRENCH
RECESS
WRENCH FLAT
op 0
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 2
W-TYPE 7
WRENCH
TFP500
Page 4 of 10
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
ORDER LENGTHS:
2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm)
IN 1/4' (6,4 mm)
INCREMENTS II I
f FACE OF
CEILING
2-3/16' ± 1/8' 3" DIA.
(55,6 ± 3,2 mm) (76,2 mm)-
FIGURE 3
PENDENT (TY3255)
WITH STANDARD ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
ORDER LENGTHS:
3-3/4" to 48"
(95,3 to 1219,2 mm)
IN 1/4" (6,4 mm) 2-1/4" DIA.
INCREMENTS (57,2 mm)
FACE OF
C 1,
'1
EILING
irn)
FIGURE 4
PENDENT (TY3255)
WITH STANDARD
RECESSED ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
LJ
ORDER LENGTHS: 'iv" rit
1/2"
(12,7 to 1
IN 1/4"
INCRE
4-1/1
(108,0
FIGURE 5
PENDENT (TY3255)
WITH DEEP ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
ORDER LENGTHS:
5" to 48"
(127,0 to 1219,2 mm)
IN 1/4" (6,4 mm)
INCREMENTS
MINIMUM
1-3/4(44,5mm)
DEFLECTOR
TO CEILING
FIGURE 6
PENDENT (TY3255)
WITHOUT ESCUTCHEON
umrwrAFAW
TOP OF
DEFLECTOR
ORDER LENGTHS:
5" to 48"
(127,0 to 1219,2 mm)
IN 1/4" (6,4 mm)
INCREMENTS
FACE OF
SPRINKLER
FITTING -
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FIGURE 7
UPRIGHT (TY3155)
WITHOUT ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
1-3/4" DIA.
(44,5 mm)
'?j (76,2 mm)
3.5
CENTERLINE 5/16"
OF WATERWAY (7,9 mm)
FIGURE 8
HORIZONTAL SIDEWALL (TY3355)
WITH STANDARD ESCUTCHEON
ORDER LENGTHS:
1/2"t045-3/4"(12,7t01162,1 mm)
IN 1/4" (6,4 mm) INCREMENTS 4-1/4" ± 1/8"
'
2-1/2' DIA. FACE OF (108,0 ± 3,2 mm)
FACE OF (63,5 mm) fl MOUNTING I
SPRINKLER H- FITTING I [SURFACE
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
_____
T (88,9 mm)
/35.
CENTERLINE 5/16"
OF WATERWAY (7,9 mm)
FIGURE 9
HORIZONTAL SIDEWALL (TY3355)
WITH DEEP ESCUTCHEON
ORDER LENGTHS:
5-1/2" to 48" (139,7 to 1219,2 mm)
IN 1/4" (6,4 mm) INCREMENTS MINIMUM
2-1/4" (57,2 mm)
FACE OF I'. DEFLECTOR TO
- SPRINKLER I MOUNTING
FITTING URFACE S
5/16" / SPRINKLER FITTING (7,9 mm)
(REFER TO DESIGN CENTERLINE
CRITERIA SECTION) OF WATERWAY
FIGURE 10
HORIZONTAL SIDEWALL (TY3355)
WITHOUT ESCUTCHEON
TFP500
Page 5 of 10
Operation
When TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers are in service,
water is prevented from entering the
assembly by the Plug with Sealing
Assembly (Ref. Figure 1) in the Inlet of
the sprinkler.
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter
the glass bulb, and the Bulb Seat is
released.
The compressed Spring is then able
to expand and push the Water Tube as
well as the Guide Tube outward. This
action simultaneously pulls inward on
the Yoke, withdrawing the Plug with
Sealing Assembly from the Inlet, allow-
ing the sprinkler to activate and flow
water.
Design
Criteria
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers are intended for
use in fire sprinkler systems designed
in accordance with the standard instal-
lation rules recognized by the applica-
ble listing or approval agency (e.g., UL
Listing is based on NFPA 13 require-
ments). For more information on LPCB
Approval, contact Johnson Controls at
the following office:
Kopersteden 1
7547 TJ Enschede
The Netherlands
Tel: +31-(0)53-428-4444
Fax: +31-(0)53-428-3377
Sprinkler Fittings
Install 1 in. NPT Series DS-1 Dry-type
Sprinklers in the 1 in. NPT outlet or run
of the following fittings:
malleable or ductile iron threaded
tee fittings that meet the dimen-
sional requirements of ANSI B16.3
(Class 150)
cast iron threaded tee fittings that
meet the dimensional requirements
of ANSI B16.4 (Class 125)
Do not install Series DS-1 Dry-type
Sprinklers into elbow fittings. The Inlet
of the sprinkler can contact the interior
of the elbow.
The unused outlet of the threaded tee is
plugged as shown in Figure 12.
ORDER LENGTHS:
2-3/4 to 48" (69,9 to 1219,2 mm)
IN 1/4' (6,4 mm) INCREMENTS
2-3/8" ± 1/8'
(60,3 ± 3,2 mm)
TFP500
Page 6 of 10
Temperatures for Heated Area(1)
Ambient Temperature 40°F I 50°F I 60°F
Exposed to (4°C) (10°C) (16°C)
Discharge End of Sprinkler Minimum Exposed Barrel Length(2),
Inches
(mm)
40°F
(4°C)
0 0 0
30°F
(-1°C) 0 0 0
20°F 4 0
(-7°C) (100) 0
10°F 8 1 (-12°C) (200) (25) 0
0°F 12 3
(-18°C) (305) (75) 0
-10°F 14 4 1
(-23°C) (355) (100) (25)
-20°F 14 6 3 (-29°C) (355) (150) (75)
-30°F 16 8 4 (-34°C) (405) (200) (100)
-40°F 18 8 4
(-40°C) (455) (200) (100)
-50°F 20 10 6 (-46°C) (510) (255) (150)
-60°F 20 10 6 (-51°C) (510) (255) (150)
Notes:
For protected area temperatures that occur between values listed above, use the next cooler temperature.
These lengths are inclusive of wind velocities up to 30 mph (18,6 kph).
TABLE C
EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS
MINIMUM RECOMMENDED LENGTHS
You can also install Series DS-1 Dry-
type Sprinklers in the 1 inch NPT outlet
of a GRINNELL Figure 730 Mechanical
Tee and GRINNELL G-FIRE Figure 522;
however, the use of the Figure 730 Tee
and Figure 522 for this arrangement is
limited to wet pipe systems.
The configuration shown in Figure 13
is only applicable for wet pipe systems
where the sprinkler fitting and water-
filled pipe above the sprinkler fitting are
not subject to freezing and where the
length of the dry-type sprinkler has the
minimum exposure length depicted in
Figure 11. Refer to the Exposure Length
section.
For wet pipe system installations of 1
inch NPT Series DS-1 Dry-Type Sprin-
klers connected to CPVC piping, use
only the following TYCO CPVC fittings:
1 in. x 1 in. NPT Female Adapter (P/N
80145)
1 in. x 1 in. x 1 in. NPT Sprinkler Head
Adapter Tee (P/N 80249)
For dry pipe system installations, use
only the side outlet of maximum 2-1/2
inch reducing tee when locating Series
DS-1 Dry-type Sprinklers directly
below the branchline; otherwise, use
the configuration shown in Figure 12 to
assure complete water drainage from
above Series DS-1 Dry-type Sprin-
klers and the branchline. Failure to do
so may result in pipe freezing and water
damage.
NOTICE
Do not install Series DS-1 Dry-type
Sprinklers into any other type fitting
without first consulting the Johnson
Controls Technical Services. Failure to
use the appropriate fitting may result in
one of the following:
failure of the sprinkler to operate
properly due to formation of ice
over the Inlet Plug or binding of the
Inlet Plug
insufficient engagement of the
Inlet pipe-threads with consequent
leakage
Drainage
In accordance with the minimum
requirements of the NATIONAL FIRE
PROTECTION ASSOCIATION for dry
pipe sprinkler systems, branch, cross,
and feed-main piping connected to Dry
Sprinklers and subject to freezing tem-
peratures must be pitched for proper
drainage.
Exposure Length
When using Dry Sprinklers in wet pipe
sprinkler systems to protect areas
subject to freezing temperatures, use
Table C to determine a sprinkler's
appropriate exposed barrel length to
prevent water from freezing in the con-
necting pipes due to conduction. The
exposed barrel length measurement
must be taken from the face of the
sprinkler fitting to the surface of the
structure or insulation that is exposed
to the heated area. Refer to Figure 11
for an example.
For protected area temperatures
between those given above, the
minimum recommended length from
the face of the fitting to the outside of
the protected area may be determined
by interpolating between the indicated
values.
Clearance Space
In accordance with NFPA 13, when
connecting an area subject to freez-
ing and an area containing a wet pipe
sprinkler system, the clearance space
around the sprinkler barrel of dry-type
sprinklers must be sealed. Due to tem-
perature differences between two
areas, the potential for the formation
of condensation in the sprinkler and
subsequent ice build-up is increased. If
this condensation is not controlled, ice
build-up can occur that might damage
the dry-type sprinkler and/or prevent
proper operation in a fire situation.
Use of the Model DSB-2 Dry Sprinkler
Boot, described in technical data sheet
TFP591 and shown in Figures 14 and
15, can provide the recommended seal.
TFP500
Page 7 of 10
FACE OF =
SPRINKLER - -
FITTING
Ir ' EXPOSURE
LENGTH
(SEE DESIGN
DSB-2 CRITERIA
INTENDED SECTION)
FOR FREEZER
STRUCTURES
FIGURE 11
EXPOSURE LENGTH
-
RUN
OUTLET
PLUGGED
SPRINKLER
FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA
SECTION)
Ezzml DSB-2
INTENDED
FOR FREEZER
STRUCTURES
FIGURE 12
SPRINKLER FITTING
UNHEATED AREA
TO WET 1fl SIDE
SYSTEM OUTLET
PLUGGED
Iij
DSB-2 SPRINKLER
INTENDED FITTING
FOR FREEZER (SEE DESIGN
STRUCTURES CRITERIA
SECTION)
ZLE"1J "
FIGURE 13
SPRINKLER FITTING
HEATED AREA
STRAP TIES
(ENDS ON
OPPOSING
SIDES OF
BOOT)
DSB-2 BOOT
ADHESIVE
1-3/4" DIA.
(44,5 mm)
CLEARANCE
HOLE
INSULATED
FREEZER
STRUCTURE
DS-1
SHOWN WITH
STANDARD
ESCUTCHEON
FIGURE 14
MODEL DSB-2 DRY SPRINKLER
BOOT WITH PENDENT SERIES
DS-1 DRY-TYPE SPRINKLER
1-3/4 DIA.
(44,5 mm)
CLEARANCE INSULATED HOLE FREEZER
ADHESIVE STRUCTURE
DSB-2 '""
BOOT \
STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT)
FIGURE 15
MODEL DSB-2 DRY SPRINKLER
BOOT WITH SIDEWALL SERIES
DS-1 DRY-TYPE SPRINKLER
TFP500
Page 8 of 10
Installation
TYCO Series DS-1 5.61K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers must be installed
in accordance with this section.
General Instructions
Series DS-1 Dry-type Sprinklers must
only be installed in fittings that meet
the requirements of the Design Crite-
ria section. Refer to the Design Criteria
section for other important require-
ments regarding piping design and
sealing of the clearance space around
the Sprinkler Casing.
Do not install any bulb-type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F (57°C) rating to
1/8 inch (3,2 mm) for the 360°F (182°C)
rating.
Obtain a leak-tight 1 inch NPT sprinkler
joint by applying a minimum-to-maxi-
mum torque of 20 to 30 lb-ft (26,8 to
40,2 Nm). Higher levels of torque may
distort the sprinkler Inlet with conse-
quent leakage or impairment of the
sprinkler.
Do not attempt to compensate for
insufficient adjustment in an Escutch-
eon Plate by under or over-tightening
the Sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Notes:
Install pendent sprinklers only in
the pendent position; install upright
sprinklers only in the upright posi-
tion. The deflector of a pendent or
upright sprinkler is to be parallel to
the ceiling.
Install horizontal sidewall sprinklers
in the horizontal position with their
centerline of waterway perpendicu-
lar to the back wall and parallel to
the ceiling. Ensure the word "TOP"
on the Deflector faces the ceiling.
Step 1. With a non-hardening pipe-
thread sealant such as TEFLON applied
to the inlet threads, hand-tighten the
sprinkler into the sprinkler fitting.
Step 2. Wrench-tighten the sprinkler
using either:
a pipe wrench on the Inlet Band or
the Casing (Ref. Figure 1)
the W-Type 7 Sprinkler Wrench on
the Wrench Flat (Ref. Figure 2)
Apply the wrench recess of the W-Type
7 Sprinkler Wrench to the wrench flat.
Note: If sprinkler removal becomes
necessary, remove the sprinkler using
the same wrenching method noted
above. Sprinkler removal is easier when
a non-hardening sealant was used
and torque guidelines were followed.
After removal, inspect the sprinkler for
damage.
Step 3. After installing the ceiling or
wall and applying a ceiling finish, slide
on the outer piece of the escutch-
eon until it comes in contact with the
ceiling/wall. Do not lift the ceiling panel
out of its normal position.
When using the Deep Escutcheon,
hold the outer piece in contact with the
mounting surface (ceiling or wall). Then
rotate the inner piece approximately 1/4
turn with respect to the outer piece,
to hold the Deep Escutcheon firmly
together.
Care and
Maintenance
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall,
Standard Response, Standard Cover-
age Dry-type Sprinklers must be main-
tained and serviced in accordance with
this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
systems from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover a
clearance hole, may delay the time to
sprinkler operation in a fire situation.
A Vent Hole is provided in the Bulb
Seat (Ref. Figure 1) to indicate if the Dry
Sprinkler is remaining dry. Evidence of
leakage from the Vent Hole indicates
potential leakage past the Inlet seal
and the need to remove the sprinkler
to determine the cause of leakage;
for example, an improper installation
or an ice plug. Close the fire protec-
tion system control valve and drain the
system before removing the sprinkler.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb (Ref. Installa-
tion section).
The owner is responsible for the inpec-
tion, testing, and maintenance of their
fire protection system and devices in
compliance with this document, as well
as with the applicable standards of the
NATIONAL FIRE PROTECTION ASSO-
CIATION (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
SIGNAL WHITE
4 (RAL9003)
POLYESTER
CHROME
PLATED
I TEMPERATURE
RATING(2)
0 135°F (57°C)
1 155°F(68°C)
2 175°F (79°C)
3 200-F (93-C)
4 286°F (141°C)
5 360°F (182°C)
ESCUTCHEON
FIN ISH(1I
SIGNAL WHITE
(RAL9003)
POLYESTER
SIGNAL WHITE
(RAL9003)
POLYESTER
BRASS
PLATED
SIGNAL WHITE
(RAL9003)
POLYESTER
CHROME
PLATED
ORDER
LEN GTH(3)
055 5.50 in.
082 8.25 in.
180 18.00 in.
187 18.75 in.
372 37.25 in.
480 48.00 in.
TFP500
Page 9 of 10
P/N* 60
- XXX - X - XXX
1. SIN SPRINKLER _L FINISH
96 Pendent with 1Y3255 CHROME Standard Escutcheon (1 in. NPT) (Figure 3) o PLATED
93 Pendent with TY3255
NATURAL Deep Escutcheon (1 in. NPT) (Figure 5)
1 -
97 Pendent with TY3255 BRASS
Recessed Escutcheon (1 in. NPT) (Figure 4)
2 92 Pendent without TY3255 NATURAL
Escutcheon (1 in. NPT) (Figure 6) BRASS
Sidewall with TY3355 94 Standard Escutcheon (1 in. NPT) (Figure 8)
53 Sidewall with TY3355
-
Deep Escutcheon (1 in. NPT) (Figure 9)
54 Sidewall without TY3355
Escutcheon (1 in. NPT) (Figure 10)
98 Upright without I TY3155 I
I Escutcheon (1 in. NPT) (Figure 7)
Notes:
Escutcheon Finish applies to sprinklers provided with escutcheons.
360F (182CC) temperature rating applies to non-recessed sprinkler
assemblies.
Dry-type Sprinklers are furnished based upon Order Length" as mea-
sured per Figures 3 through 10, as applicable, and for each individual
sprinkler where it is to be installed. After the measurement is taken,
round it to the nearest 1/4 inch increment.
Use Prefix I" for ISO 7-R 1 Connection (e.g., 1-60-961-1-180).
TABLED
SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE
PART NUMBER SELECTION
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indi-
cate the full product name, including
description and part number (P/N).
Dry-type Sprinklers
When ordering Series DS-1 5.6K
Pendent, Upright, and Horizontal Side-
wall, Standard Response, Standard
Coverage Dry-type Sprinklers, specify
the following information:
SIN:
1Y3255 - Pendent
TY3155 - Upright
1Y3355 - Horizontal Sidewall
Order Length:
Dry-type Sprinklers are furnished
based upon Order Length as mea-
sured per Figures 3 through 10, as
applicable. After the measurement is
taken, round it to the nearest 1/4 inch
increment.
Inlet Connections:
1 Inch NPT
(Standard)
ISO 7-R 1
(For information on ISO Inlet Thread
Connections, contact your Johnson
Controls Sales Representative.)
Temperature Rating
Sprinkler Finish
Escutcheon Type and Finish, as
applicable
P/N from Table D
Part numbers are for 1 inch NPT
standard order sprinklers. Orders
for all other sprinkler assemblies
must be accompanied by a complete
description.
Sprinkler Wrench
Specify W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
Sprinkler Boot
Specify Model DSB-2 Dry Sprinkler
Boot, P/N 63-000-0-002
This part number includes one (1) Boot,
two (2) Strap Ties, and 1/3 oz. of Adhe-
sive (a sufficient quantity for installing
one boot).
TFP500
Page 10 of 10
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 f
02058 Johnson Controls. All rights reserved. All specifications and Other information shown were current float document revision data and are subject to change without notion. Johnson ''1
NATIONAL FIRE PROTECTION ASSOCIATION and NEPA nre registered Iredemarks NI saAonal Fire PrcIanIiAfl Assaciatinn
TEFLON ca ragistarod Ired arnarir al OrrPca,I Controls
Page 1 0f4
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
DESCRIPTION
The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small,
thermosensitive, glass-bulb spray sprinkler available in several differ-
ent finishes and temperature ratings to meet design requirements. The spe-
cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in
decorative applications where colors are desired. In addition, these coat-
ings have been investigated for installation in corrosive atmospheres and
are listed/approved as corrosion resistant as indicated in the Approval
Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM
Global has no approval classification Polyester coatings as corrosion resistant.)
2. LISTINGS AND APPROVALS
cULus Listed: Category VNIV
FM Approved: Classes 2002 and 2020
Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)*
Maximum Working Pressure: 175 psi (12 bar) wwp.
Factory tested hydrostatically to 500 psi (34.5 bar)
Testing: U.S.A. Patent No. 4,831,870
Thread size: 1/2" NPT, 15 mm BSP
Nominal K-Factor: 5.6 U.S. (80.6 metric**)
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-3/16" (56 mm)
*CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY is 5 psi (0.35 bar).
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Brass UNS-C23000 or Copper UNS-C19500
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For Polyester Coated Sprinklers: Belleville Spring-Exposed
For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated
Ordering Information: (Also refer to the current Viking price list.)
Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and
then the appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN
Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° E, and 286°/141° = G
For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the Viking website.)
Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017)
Sprinkler Cabinets:
Six-head capacity: Part No. 01724A (available since 1971)
Twelve-head capacity: Part No. 01725A (available since 1971)
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2
(Replaced wrench 10896W/B with 21475M/B)
Page 2 of 4
MICROFAST® QUICK '4J II(IIts1G ® RESPONSE UPRIGHT
SPRINKLER VK300 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
OPERATION
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
AVAILABILITY
The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors.
See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
f3:1IflAVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
.ktinkIrTèerat&re Sprinkler Nominal Maximum Ambient : Bulb Color
-• CIassification. Temperature Rating1 Ceiling Temperature'
Ordinary 135 °F (57 °C) 100 ¶ (38 °C) Orange
Ordinary 155 °F (68 C) 100 ¶ (38 °C) Red
Intermediate 175 °F (79 C) 150 °F (65 C) Yellow
Intermediate 200 °F (93 C) 150 ¶ (65 C) Green
High 286 ¶ (141 C) 225 ¶ (107 °C) Blue
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT
Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 ¶ (57 C)
Footnotes
1 The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-
ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only.
Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated.
Protective Sprinkler Cap—
Wrench Flat
Figure 1:
Standard Sprinkler Wrench 21475M1B
Form No. F_052114 17.10.05 Rev 17.1
Page 3 of 4
I MICROFAST® QUICK 1(1 8 RESPONSE UPRIGHT
SPRINKLER VK300 (K5.6)
ium7W
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart I (UL) r_ Temperature KEY
Microfast Quick Response Finish
AIX 4- Escutcheon (if applicable) Upright Sprinkler VK300
Maximum 175 PSI (12 bar) WWP
Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN Number' NPT BSP U.S. metric2 Inches mm cULus VdS LPCB NYC- CE
12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 1 56 Al, B2 -- -- See footnote 7. --
NOTICE Product Below Limited Availability
06661B I VK300 I 1/2" 1 15 mm 1 5.6 1 80.6 1 2-3/16 56 I Al, B2 -- -- ISee footnote 7.I --
Approved Temperature Ratings Approved Finishes A-135°F(57°C) 155°F(68"C)
,
175°F(79°C) 200°F(93°C)
'
and
I''' "
1 - Brass, Chrome, White Polyester-1.6, and Black Polyester5'6
B - 155 °F (68 °C), 175 °F (79 °C) 200 °F (93 °C), and 286 °F (141°C) 2-ENT6
Footnotes
'Base part number is shown. For complete part number, refer to Viking's current price schedule.
2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada
Other colors are available on request with the same Listings and Approvals as the standard colors.
6 cULus Listed as corrosion resistant.
Meets New York City requirements, effective July 1, 2008
°Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16.
DESIGN CRITERIA - UL
(Also refer to Approval Chart 1 above.)
cULus Listing Requirements:
The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the
latest edition of NFPA 13 for standard spray sprinklers.
Designed for use in Light and Ordinary Hazard occupancies.
The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form
No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in
accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F052114 17.10.05 Rev 17.1
Page 4 of 4
® MICROFASP QUICK \J I K1 Fs1G RESPONSE UPRIGHT
SPRINKLER VK300 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart 2 (FM) Temperature KEY
Microfase Quick Response Finish
AIX 4— Escutcheon (if applicable) Upright Sprinkler VK300
Maximum 175 PSI (12 bar) WWP
Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3
Number' SIN (Refer also to Design Criteria below.) NPT I I BSP U.S. I metric2 Inches mm
12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2
NOTICE - Product Below 7TTlLocal 'n r.iir
06661B VK300 1/2" 1 15 mm 1 5.6 80.6 2-3/16 56 Al, B2
Approved Temperature Ratings Approved Finishes 1 - Brass, Chrome, White Polyester', and Black °F °C), °F °C), °F °C), °F °C), °F A - 135 (57 155 (68 175 (79 200 (93 and 286 (141°C) Polyester °F °C), °F B - 155 (68 175 °F (79 °C), 200 °F (93 °C), and 286 (141°C) 2 - ENT6
Footnotes
1 Base part number is shown. For complete part number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
'This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals.
Other colors are available on request with the same Approvals as the standard colors. e FM approved as corrosion resistant.
DESIGN CRITERIA - FM
(Also refer to Approval Chart 2 above.)
FM ArovaI Reciuirements:
The Microfast Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM
Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data
Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic
design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form
No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in
accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2
(Replaced wrench 10896W/B with 21475M/B)
Page 1 of
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
DESCRIPTION
The Viking Microfasta Quick Response Upright Sprinkler VK300 is a small,
thermosensitive, glass-bulb spray sprinkler available in several differ-
ent finishes and temperature ratings to meet design requirements. The spe-
cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in
decorative applications where colors are desired. In addition, these coat-
ings have been investigated for installation in corrosive atmospheres and
are listed/approved as corrosion resistant as indicated in the Approval
Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM
Global has no approval classification Polyester coatings as corrosion resistant.)
LISTINGS AND APPROVALS
cULus Listed: Category VNIV
FM Approved: Classes 2002 and 2020
Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)*
Maximum Working Pressure: 175 psi (12 bar) wwp.
Factory tested hydrostatically to 500 psi (34.5 bar)
Testing: U.S.A. Patent No. 4,831,870
Thread size: 1/2" NPT, 15 mm BSP
Nominal K-Factor: 5.6 U.S. (80.6 metric**)
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-3/16" (56 mm)
*cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY is 5 psi (0.35 bar).
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Brass UNS-C23000 or Copper UNS-C19500
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For Polyester Coated Sprinklers: Belleville Spring-Exposed
For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated
Ordering Information: (Also refer to the current Viking price list.)
Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and
then the appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN
Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G
For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB
Available Finishes And Temperature Ratings: Refer to Table 1.
Accessories: (Also refer to the Viking website.)
Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017)
Sprinkler Cabinets:
Six-head capacity: Part No. 01724A (available since 1971)
Twelve-head capacity: Part No. 01725A (available since 1971)
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2
(Replaced wrench 10896W/B with 21475M/B)
Page 2 of 4
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
OPERATION
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
AVAILABILITY
The Viking Microfast' Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors.
See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
TABLE 1 :AVAILABLE SPRINKLER TEMPERATURE
SprinklerTernperáture Sprinkler Nominal Maximum Ambient Bulb Color Classificatiô?i Temperature Rating' Ceiling Temperature'
Ordinary 135 F (57 C) 100 °F (38 °C) Orange
Ordinary 155 °F (68 °C) 100 °F (38 °C) Red
Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow
Intermediate 200 °F (93 °C) 150 °F (65 °C) Green
High 286 °F (141 °C) 225 ¶ (107 °C) Blue
Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT
Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C)
Footnotes
1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-
ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only.
Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated.
Protective Sprinkler Cap—
Wrench Flat
Figure 1:
Standard Sprinkler Wrench 21475M/B
Form No. F052114 17.10.05 Rev 17.1
Page 3 of 4
MICROFASTO QUICK
tIII
II(IIS1G® RESPONSE UPRIGHT
SPRINKLER VK300 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart I (UL) Temperature KEY I Finish Microfase Quick Response All X4- Escutcheon (if applicable) Upright Sprinkler VK300
Maximum 175 PSI (12 bar) WWP - - -
Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN Number' U.S. I metric2 Inches I mm cULus I VdS LPCB NYC- NPT I BSP
VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 ootnote 7.1
(•)tL
06661B VK300 1/2" I 15 mm 5.6 I 80.6 2-3/16 -- jsee footnote 7.1 -- 56 A1,132
Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and
286°F (141°C) - Brass, Chrome, White Polyester56, and Black Polyester56
B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - [NT6
Footnotes
'Base part number is shown. For complete part number, refer to Viking's current price schedule.
2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada
Other colors are available on request with the same Listings and Approvals as the standard colors.
6 cULus Listed as corrosion resistant.
Meets New York City requirements, effective July 1, 2008
6Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16.
DESIGN CRITERIA - UL
(Also refer to Approval Chart 1 above.)
cULus Listing Requirements:
The Viking MicrofastO Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the
latest edition of NFPA 13 for standard spray sprinklers.
Designed for use in Light and Ordinary Hazard occupancies.
The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form
No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in
accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F052114 17.10.05 Rev 17.1
Page 4 of 4
MICROFASP QUICK NIKJ A A A
SPRINKLER VK300 (K5.6)
RESPONSE UPRIGHT
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com
Approval Chart 2 (FM) Temperature KEY I
Microfast€ Quick Response Finish
AIX *— Escutcheon (if applicabie)j Upright Sprinkler VK300
Maximum 175 PSI (12 bar) WWP -
Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3
NPT I BSP U.S. metric2 Inches I mm Number' (Refer also to Design Criteria below.)
12978 VK300 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2
NOTICE Product I Limited TAvailability (Th T7l VikingI.11it
06661B VK300 1 1/2" 15 mm 1 5.6 1 80.6 2-3/16 56 Al, B2
Approved Temperature Ratings Approved Finishes
A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 1 - Brass, Chrome, White Polyester', and Black
B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester5
2 - ENT6
Footnotes
1 Base part number is shown. For complete part number, refer to Viking's current price schedule.
2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
'This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals.
Other colors are available on request with the same Approvals as the standard colors.
e FM approved as corrosion resistant.
DESIGN CRITERIA - FM
(Also refer to Approval Chart 2 above.)
FM Aooroval Requirements:
The Microfast Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM
Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data
Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic
design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria.
IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form
No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in
accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2
(Replaced wrench 10896W/B with 21475M/B)
FPC20I9-0006 ito
6021 INNOVATION WAY #400
I EUREKA - SPRINKLER TI (41 HEADS)
2132611400
1/16/2019
FPC20I9-0006