HomeMy WebLinkAbout2875 LOKER AVE E; CS; CBC2019-0253; Permit(City of
Carlsbad, Building Permit Finaled
Commercial Permit
Print Date: 02/16/2021
Job Address: 2875 LOKER AVE E, U CS, CARLSBAD, CA 92010-6626
Permit Type: BLDG-Commercial Work Class: Tenant Improvement
Permit No: CBC2019-0253
Status: Closed - Finaled
Parcel U: 2090831000
Valuation: $50,000.00
Occupancy Group:
Uof Dwelling Units:
Bedrooms:
Bathrooms:
Track U:
Lot U:'
Project U
Plan U:
Construction Type:
Orig. Plan Check U:
'Plan Check U:
DEV00082
Applied: 05/29/2019
Issued: 01/06/2021
Finaled Close Out:
Inspector: TAIva
Final Inspection: 02/16/2021
Project Title: TECH BI LT WAREHOUSE SD 377-04
Description: T-MOBILE: INSTALL 6 ANTENNAS AND EQUIPMENT
Property Owner:
TECH BILT CONSTRUCTION CORPORATION
3575 KENYON ST
SAN DIEGO, CA 92110
Contractor:
DAVIES ELECTRIC CO INC
9085 KENAMAR DR
SAN DIEGO, CA 92121-2421
(858) 578-7454
FEE AMOUNT
BUILDING PERMIT FEE ($2000+) ' $406.00
BUILDING PLAN CHECK FEE (BLDG) ' ' $284.20
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $43.00
5B1473 GREEN BUILDING STATE STANDARDS FEE • ' $2.00
STRONG MOTION-COMMERCIAL $14:00
Total Fees: $749.20 • Total Payments To Date: $749.20 Balance Due: $0.00
Please take NOTICE that approval of your project includes the Imposition' of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have-90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page ,1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov
COMMERCIAL
Plan Check ca.çg! 3
City of BUILDING PERMIT
Est. Value
Carlsbad APPLICATION PC Deposit
B2 Date___________
Job Address 2875 L.oker Avenue Suite: E APN: 209-083-10
Tenant Name: 1-Mobile CT/Project It:________ Lot It:________
Occupancy. _U Construction Type: V Fire Sprinklers: yes / no Air Conditioning: yes / no
Me
OF WORK:
Addition/New -. New SF d ise," -'New SF and Use,
Deck SF, Patio Cover SF (not Including fiatwork)
() Tenant improvement NoChange SF, Existing Use retecommunicatlonspropo$ed Use Telecommunications
____________SF, Existing Use Proposed Use ______________
Pool/Spa: __________SF Additional Gas or Electrical Features?
Soiar. KW, _____ Modules, _______ Mounted, Tilt Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No
Plumb ng/Methanlca)/Elec cal Only:__________________________________________________
0 Other.
APPLICANT (PRIMARY) PROPERTY OWNER
Name: Lauren Richards obo 1-Mobile Name: lechblit Construction Corp.
Address: 5015 Shorehame P1, Ste. 150 Address: 3575 Kenyon Street
City. San Diego State: CA Zip: 92122 City: San Diego State: CA Zip: giig
Phone: (480) 735-4868 Phone: (619) 223-1663
Email: Lauren.Richards@sacw.com Email:
DESIGN PROFESSIONAL
Name: Nestor Popowych
Address: 5015 Shoreham P1. Ste, 150
City: San Diego State: (A Zip: 92122
Phone: (61-91736-3766
Email: DeflnIS.yOshii@saCW.cOm
Architect State License: C-27496
CONTRACTOR BUSINESS
Name: Dit £\&i.
Address: 'WA S jt1 ,A
Phone: - 1~1)c- -7 \t
Email:
State Uc Bus.
(Sec. 10313 Business and Professions Code: Any City or County which requires a permit to construct, alter. Improve, demolish or repair any structure, prior to its
issuance, siso requires the applicant for Such permit to file a signed statement that he/site Is licensed pursuant to the provisions of the Contractor's License law
(Chapter 9. commendIng with Sed$on 7000 of OMsion 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged
exemptlOmArryAftlion of Section 70313 by any applicant for a permit subjects the applicant 103 CMI penalty of not more than five hundred dollars ($500)).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602.2719 Fax: 760-602-8558 Email: Suiidlng@carlsbadca.gov
8-2 Page 1 or 2 Rev. 06/18
Scanned with CamScanner
Jeuue3we3 qitM pauueog
9L/90 ^AGH JO0C0d
A0eipBqpPupfln9 :Qew3 4 6ILZ-O9091 :qo BOOM VD 'paqsie aAy Aepeie 5E9t
:jy
pawl
\)?7 'UfljVNDIS1NV3flddV
uoiW
ouh,e)e opqgjopapuadnSs4))wJadI4iflqpa 2q)WJad
pans uziadAaaq oaw1G
U) SiO)S 4aA0saJnpnJl1)o UC$PW$UO3J0 UO)UjOW put dtp AS'o SUOfl2A2 JOJ paunboa Si )4w 301 VMuVy'jjj
303N3flO3CNlALO0M)SNNDY3fll03Y/.VMM4Y MAW) )GIHM O0NY4$0 U43WD0UflU1W1SNIY9V0VALD3HISS31WIM4
dmcNvAw43oNrMvsou3ovosw rSwdmd uoIOadsu, joi Mtdwd paUonUtw aoqaqi uodn p2qpuJ4olgoqJJo ouaJoqlne4taqI
u0n3ru1su0,2u1punq oneitJs'el atqS PUB S33U11pJo AM
fit uw* Aidutol oaJt 1,alemm SisuSid a4l uo ueuuoju jetil put pi q UCPeWJOjtm aAoqeaq rn; titis put uofle3ljddl ;qi pai aeq
:QjyJ33 1NV51ddV
13W1S10 10W.NO3 NOWU1O4 WV 3)41 ONY mlAli3A3N3DiDV)3 O 331110344110 SLN3PJ3lflflb3U
3441944t13]t)4 SI 130 13 VJ SVI41NV3flddV 3441553INfl 03115513210)4 AVIN ANYd00 40 31V3111W33 WNU V '53A 313V513]MSNV3)U 10 ANY II
ON 13 SAC) oolpueJoMepunoqJinoq14opj0o0'5uIquImp3i3flJ1SuO)aqO4AiiPRJ34lSI
°N 0 511 0 LPIfl5lP W;Wt3tutW Aiitnb J)t JO 13IJI 40flU0) UO)11j)cd 428141 WO$J ))WJ3d o ujeqo 0) pl)4nb81 )u2dn100 3ujj*nq ininj oiuti*jdde a(o U
ON C SA Q JVV I0003V MnKnS SflOPJ222H 13UU2112)SWd 214140 PESS AD fESSZSDM SUQIPISJIPW1 w1la4
uqtuaQjdpueluawaSeutw4qjjouuoluollejjqfajsi"lewsnopineqA4avm*ueldssaulsqe;twqmcnpjlnb,7jiuedn=&MpqajMnjjotumWdea4isI
:p10 S1HNWd 9NIa1In8 1VILN301S1H-NON HOT NOtLS 9NIM011Oi 3W. 3131dI0 A1NO
.swppv WAPual :4*1*2)3 s,Jtputi
(apo u"o (i) 160t 33$ p3fl22) SI 11wad sito *(JOM 14140 uewioiad gin 10j A,uo2e 2UPAI u0133042u03 I Si 4*4) 11141 WIW2 Aqjq i
ANVJ AZIN39V9NION31 NOU.flHJ.SNO3
:ajyo 1N39V0 :3llflLVN9IS H3NM0
:(poMJo 2dM auoqd /ss2ippt / tutu pfl)3UlJ parnpui )JOM 24) 8p)AOJd o*suotad 2U)M0140J 114) (p4*jq) P413V)UOU Atq I IOU VOM Q411140 111*02 1pslojd inn I S :034w0u 22U33f3 2J0peflU
/ u04d /swppe,tu*vu apnpuj 4jam*o(tui ato aWojd put ;sdrn aieuip*000i uosJOd WtMOHOJ3*414*49 114 iinq osuopod 3pid01 uld I It
:(aqwflu 85U83u .ssoir4uo3 /tuoqd /ssppe tutu tpnp*q) ucHwulsuw pasodoid aqi apsotd oa (uuij) uotud 2uooj 34) 4i1 p213141*03 3M4 t E
aom p3sodojd 1111 404 14uuad &4PIInq c JOJ uo)io*jdde u9pu2s (iou rni /at*i) ii
ON 13 2210 )UawaA0Jdu4 Auodoid ptsodod t4) 40 u0)4)*u;5u03 ioj 5411*3)2W put ,oqei *ofew 1Waid oi ued Mjtuos*d
:uostt, sqi 40) 3PO3 tuaimpm put sstuusna uoas Japun Idwan wt I
i 32u13r15.JOPIJUO) tsp 0) U=Sxld
pasu3 (s)iopvuo qijm spafoJd ipns ioj 2)3241*103 put uoaip saAoJdwI 40 spnnq oq*Auadoid jo jtumo Ut 0) 4)ddt IOU stop Am asumn SI0P24uo3
aqL:apo3 SUOlS23JOJd put 251*2151*9 '"ot 32s) *id aqi psusuo, 01 SiO)324u03 p45u1311 4102*14)324)1*03 ARWPO uWAVadoidaq140 numo sit a
(ales joasodind 119 104 asoiduSi sop4lnq iou pp aq 41141 2uoid Jo utpinq aqi 2AC144)M Jtpnq.ituo tsp uOp2)duao3 ja ieai auo
U)414M 13J0$ if )UtwaAOldwj JO ButAinq asp 'aanoq I 2)25 Jo) p443440 40 p4PU3IUI lOU lit SWa4UW*oidwi 4is 1141 pap)Aoud 'a1o3dwa *11*0549 42i)oqi JO 4132W44
liom pns stop 041* put UOa4aq) 12104dU4 Jo spnnq 041* Adoid jo 44*11*0 Ut 01444dd1 iou saop M214SUtofl $.i01324W03 341 4P03 2U01528)OJd Pus 522*2151*9
a) SitS JO) 98*344040 P3PU3I4 IOU $I lifl)3114)5 III) put NJQm 2910914)1* U0925u8dW03 34024134)52 SaSEM 'pjm saal.01dwa 1w 10 Autdoid 314) 40 jawAO st I 0
:uosoai 5uJM00Jaq) AOJMD7 aSUp s,japoj4u(yj w04f )dwra wo I jolpwJffo (qazaq
NOIiJy]O U3011fl8-U3NM0 (9 NOU.do)
) 1"J.0
3U(IJyN9
1141 uenspu*ua*alsq
4 40 9015 *1041.315*4Jai ptp)A0id to 213.wtp 'uopesulduoajo 311410) 34) U9)P. uj o; do stuij "pus sapvuad )!u)u4*3
oi iaAcdwt is p.fspts jeqs put inIMlIUSI t3taso, uopesusdwqt saIion Ii .ann,i:wflIvM Siw041133 403*34 uc *SutdU103 213440M 441 0) pllqns
awo3aqo1seoauulwMuocJadAutA04dw3)ou [Iola p'pnssIcwadsjqi pIMJOJ4OM444j023u1w.soyadqq)pu;/4))3a]uo41dW3X3JOa)t3*JI)J3
\ 01111113 U01142,111113 \) \QJ4 0444bU04
Y) V'QJ'1 i% c91't IOWV)4 /w USD3 #3U13n5U1 241 J3UWflU 13fl0d put jaWm 33ueu0UadW03 5*ts)iOM Ap
p3fl55) SI )IW41d 5)14)5134141*404 1(401*341)0 ;3u2114)bilad 34) 404 103JOfl 34140 OOLE UOfl31S Aq pli4l*b3J 21 luopetuadwoo 5)31.AOM U4)1UL2W 14)1* put
92025) SI IIUL*3d 514)513)41*4201* 14)J0 23*ieWiOp8d3*U 104 4p03 JOUll 34140 001140041451q papsold UOflt5U3dW03 .2434201*404 I1ns1lI13s Of lumoop 34!3UIU03IIMB1UI2W inn put aei ,c
:5u0polopap 6l4MoljoJaipfo MAInpadja 4IbUd4 apun ulqgo s(qoaq
NOIiVliV1330 NO JVSN3d1NO3.SH3WOM :( y N0u40)
Co'
Building Permit Inspection History Finaled
City of
Carlsbad
Permit Type: BLDG-Commercial Application Date: 05/29/2019 Owner: TECHBILT CONSTRUCTION
CORPORATION
Work Class: Tenant Improvement Issue Date: 01/06/2021 Subdivision: PARCEL MAP NO 15563
Status: Closed - Finaled Expiration Date: 08/16/2021 Address: 2875 LOKER AVE E, # CS
lVR Number: 19370 CARLSBAD, CA 92010-6626
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01125/2021 01/25/2021 BLDG-14 149052.2021 Passed Tony Alvarado
Frame/Steel/Bolting/We
Idling (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency - - January 25, 2021: no building deficiencies.
AT&T Cell-site antennas equipment area,
remodel/alteration to existing building
exterior equipment box.
rough framing of existing FRP equipment
boxes —to be enlarged equipment exterior
building bbxes-per architectural and
structural engineer plans and detailed
specifications-approved.
Approved per engineering sheet detail
S-i.
Passed
Yes
(omplete
02116/2021 02116/2021 BLDG-34 Rough 150603-2021 Passed Tony Alvarado Complete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency February 16, 2020: - . Yes
No building deficiencies.
1. T-MOBILE: INSTALL 6 ANTENNAS AND
EQUIPMENT, Per structural engineer plans
and detail specifications, scope of
remodel/alteration of existing (6)
antennas-approved.
BLDG-Final Inspection 150602-2021 Passed Tony Alvarado
Checklist Item COMMENTS Passed
BLDG-Structural Final February 16, 2020: Yes
NO building deficiencies.
1. T-MOBILE: INSTALL 6 ANTENNAS AND
EQUIPMENT, Per structural engineer plans
and detail specifications, scope of
remodel/alteration of existing (6)
antennas-approved.
BLDG-Electrical Final February 16, 2020: Yes
No building deficiencies.
1. T-MOBILE: INSTALL 6 ANTENNAS AND
EQUIPMENT, Per structural engineer plans
and detail specifications, scope of
remodel/alteration of existing (6)
antennas-approved.
Complete
Tuesday, February 16, 2021 . Page 1 of 1
EsGil
A SAFEbuiUCompany
DATE: 6/7/2019
JURISDICTION: City of Carlsbad
PLAN CHECK #.: CBC2019-0253
PROJECT ADDRESS: 2875 Loker Ave.
SET:!
IJ APPLICANT
U JURIS.
PROJECT NAME: T-Mobile Techbilt Warehouse SD06377A
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted
Mail Telephone
LI REMARKS:
(by: ) Email:
Fax In Person
By: David Yao Enclosures:
EsGil
5/31/19
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
City of Carlsbad CBC2019-0253
6/7/2019
[DO NOT PAY- THIS IS NOTANINVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK #.: CBC2019-0253
PREPARED BY: David Yao DATE: 6/7/2019
BUILDING ADDRESS: 2875 Loker Ave.
BUILDING OCCUPANCY:
BUILDING
PORTION
AREA
(S q. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
cell site revisions per city 50,000
Air Conditioning
Fire Sprinklers
TOTAL VALUE 50,000
Jurisdiction Code cb 1By Ordinance
Bldg. Permit Fee by Ordinance v
Plan Check Fee by Ordinance V
Type of Review: E Complete Review fl Structural Only
Repetitive Fee
Repeats
LI Other
El
Hourly Hr. @ *
EsGil Fee I $244.671
Comments:
Sheet of
5015 Shoreham Place, Suite 150
San Diego, CA 92122
(0) (619) 736-3766
(F) 619.736.3721
www.sacw.com
Site development, Architecture & engineering, Construction
Structural Calculations
AE1516
Revision Designer Date Revision Designer Date
0 RE 6/15/2018
Carrier Designations: 1-Mobile
Project: L700
Site Name: Techbilt Warehouse RECE IVED Site Number: SD06377A
Site Address: 2875 Loker Avenue E MAY 29 2019 Carlsbad, CA 92008
CITY OF CAi-LSBAD
Scope of Work: Evaluate proposed appurtenances support elements. BUILDING DIVISION
Site Data: Seismic Design Category: D
Soil Class: D
Short Period Spectral Response Coefficient, SDS: 0.748
Wind Design Category: C
Base Wind Speed, V51: 110 mph
Standards: . CCR Title 24 Part 2, California Building Code (Latest Edition)
>0 ASCE 7 Minimum Design Loads for Buildings and Other Structures
TIA-222-G Structural Standard forAntenna Supporting Structures and Antenna
ANSl/AlSC 360 Specification for Structural Steel Buildings
ACI 318 Building Code Requirements for Structural Concrete
ACI 530 Building Code Requirements & Specification for Masonry Structures
ANSl/AWC NDS National Design Specification for Wood Construction
77991
Ex Or UW1 q 6/3 19 M
CIV1
PM /22/19
IPages/Sheets covered by this seal:
Scanned, electronic, or other reproductions of this Structural Calculation may be provided for recording purposes or to expedite the receipt of information. In
no event shall this document be used as a certified version of the Structural Calculation unless a wet seal and signature is present.
1of 20
SEE
WIRELESS
SAC AC OCSJGN GROUP INC
Provisions of Analysis and Disclaimer:
Unless agreed upon by both Customer and SAC Wireless, LLC ("SAC"), in a separate written agreement, the analysis
contained herein is performed to the minimum design wind, ice, and other environmental loading prescribed by the
governing building codes and standards. Any higher loading conditions required by the local jurisdiction or
structure owner should be made known to SAC immediately for analysis. No lesser conditions will be
accommodated. Although SAC shall make every effort to ensure the loading considered is adequate to meet the
requirements of all applicable regulatory entities, SAC provides no other assurances on any other local and state
codes or requirements. If wind or ice or other relevant parameters are different from the minimum values
recommended by the local adopted code, Customer shall specify the exact requirements.
The analysis performed is to the theoretical capacity of the members and connections. No accommodations are
taken for any damaged, rusted, deteriorated, or otherwise compromised member conditions. The members and
components of the structure/tower analyzed herein are assumed to be monitored and properly maintained. THE
ANALYSIS SHALL NOT BE CONSIDERED A CONDITION ASSESSMENT OF THE STRUCTURE. It is the responsibility of
Customer's contractor to notify Customer and SAC of any fatigued or compromised components prior to
construction so appropriate measures are implemented if required.
The Customer information supplied to SAC for analysis is assumed by SAC to be accurate and up to date. SAC has
not performed any verifications, including the information supplied by Customer. Customer has the sole
responsibility to ensure the information provided to SAC and used in the performance of SAC's engineering services
is correct and complete. In the absence of any information to the contrary, SAC assumes all structures were
constructed in accordance with the drawings and specifications produced by SAC and that their capacity has not
significantly changed from the "as new' condition. In addition, in the absence of building plans or original
construction documentation, the proposed design can only be determined from observable field data and are
supplemented by best judgment and experience. If any additional information is presented at any time that
contradicts what is referenced in the analysis, the analysis is invalid and must be performed again with the new
information.
Construction not performed in accordance with the provisions and conditions contained herein will void this report.
It is assumed that construction drawings and performance of work shall be modified to comply with the conditions
and limitations determined herein. SAC DECLINES ANY AND ALL RESPONSIBILITY FOR DAMAGES THAT
ORIGINATED PRIOR TO THE PROPOSED MODIFICATIONS/ADDITIONS OR FOR THE ACCURACY OF
DESIGN/CALCULATIONS DONE BY OTHERS OR FOR VARIATIONS IN THE DESIGN AND FIELD CONDITIONS, AS WELL
AS ANY AND ALL DAMAGES RELATED TO CUSTOMER'S FAILURE TO PROVIDE ACCURATE INFORMATION FOR THE
ANALYSIS. Discrepancies between field conditions and this report should be immediately brought to the attention
of SAC for review. Customer assumes full responsibility for rework associated with the differences related to
Customer's initially provided information.
2 of 20
6/13/2018 Design Maps Summary Report
USGS Design Maps Summary Report
User—Specified Input
Building Code Reference Document ASCE 7-10 Standard
(which utilizes USGS hazard data available i 2008)
Site Coordinates 33.132110N, 117.24875°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category 1/11/111
- V4ky
Center
wort If Z11
Oceansäd' Vista -
Carlsbad"
Sn Marcos
Escondido
USGS—Provided Output
S = 1.033 g SMS = 1.122 g S0 = 0.748 g
= 0.401 g SMI = 0.641 g SD1 = 0.428 g
Fo- information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and
de:erministic ground motions in the direction of maximum horizontal response, please return to the application and
sect the "2009 NEHRP" building code reference document.
MCE1 Response Spectrum Design Response Spectrum
IAN
Pcrlod. T 4 Pcrkid I ts
For PGA,, TL, CRS, and C 1 values, please view the detailed report.
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
accuracy of the data contained therein. This tool is not a substitute for technical subject-matter <nowledge.
3 of 20
&longitude=-117.248747&siteclass=3&ri... 1/1
Structural Analysis 06/15/2018
SAC AE Design Group, Revision 0 SD06377A
RE
WIRELESS
1. Design Load Calculations
Seismic Loads
Latitude and longitude were determined from Construction Drawings and confirmed using GoogleEarth. Design spectral
acceleration parameters were obtained using a program hosted at the USGS website.
Latitude: 33.13210821 2 S= 1.033 g (from USGS)
Longitude: -117.248747 2 Fa 1.09 (from USGS)
Telecommunication cabinets, radio equipment, and appurtenances are non-structural components to be designed under the
provisions of ASCE 7-10, chapter 13.
Amplification Factor, ap:
Response Factor, R:
Occupancy Category:
Importance Factor, I:
Site Class:
Connection Height, z:
Building Height, h:
Calculations
SDS =
Seismice force: Fp = (0.4apSDsWP)/(RI,/lP)*(1+2z/h) =
Mix =0.3S05lW.
F, max =6SDslPWP=
Use Eh = QE =
1.0 (ASCE 7-10, table 13.6.1)
2.5 (ASCE 7-10, table 13.6.1)
11 (ASCE 7-10 table 1.5-1)
1.00 (ASCE 7-10 13.1.3)
D (no soil report)
28.0 ft
28.0 ft
0.748 g
0.359 W, (ASCE 7-10 13.3-1)
0.224 W, (ASCE 7-10 13.3-2)
1.197 W, (ASCE 7-10 13.3-3)
0.359 W
Wind Loads
Wind forces for building appurtenances are determined in accordance with ASCE 7-10 chapter 29.
Category: 11
Basic Wind Speed: V = 110 mph (ASCE 7-10 section 26.5)
Exposure Category: C (ASCE 7-10 26.7.3
Height Above Ground, z = 28.0 ft
K= 2.01(Z/Zg)= 0.968 (ASCE 7-10 Table 29.3-1)
Ka = 0.85 (ASCE 7-10 Table 26.6-1)
K= 1.0 (ASCE 7-10 section 26.8.2)
Velocity Pressure with no Ice: q,= 0.002561(ZKZtKdV2 = 25.49 psf (ASCE 7-10 29.3-1)
Minimum Design Wind Loading, q,,,,, = 16.0 psf (ASCE 7-10 29.8)
Use q, = 25.49 psf
Horizontal Building Dimension Normal to Wind, B = 154.0 ft
Mean Roof Height, h = 28.0 ft
i = MAX(0.6h, zmin) = 16.8 (ASCE 7-10 26.9.4)
l = c*(33/)'l'G = 0.224 (ASCE 7-10 26.9-7)
L = l*(/33) = 436.8 (ASCE 7-10 26.9-9)
Q= [1/(1+0.63*((B+h)/L)063)]2 = 0.857 (ASCE 7-10 26.9-8)
G = 0.925*[(1+1.7g0lQ)/(1+1.7gl)] = 0.85 (ASCE 7-10 26.9-6)
4 of 20
Structural Analysis
SAC AE Design Group, Revision 0 .dJ
SL
WIRELESS
Table 1.1: Excerpt from ASCE 7-10 Table 29.3-1 for Wind Load calc.
Expos a z8 1nhln C
B 7 1200 30 0.3 320 0.333333
C 9.5 900 15 0.2 500 0.2
D 11.5 700 7 0.15 650 0.125
Table 1.2: Appurtenances Properties
06/15/2018
S006377A
RE
Description Weight
(Ibs)
Height
(in)
Width
(in)
Depth
(in)
RRU4449 74 14.95 13.98 9.25
APXVAAR18_43-U 106 72 24 8.5
Screen 1 112 1 84 1 96 27.96
Proposed
Proposed
Table 1.3: Appurtenances wind and seismic forces
Description
Wind Forces Seismic Forces
Cf front Cf,sde Affront
(ft')
A sIde
(ft')
Ffrontb
(lbs)
FsIde'
(Ibs)
QE
(Ibs)
0.2SDsD
(Ibs)
RRU4449 1.806 1.838 1.5 1.0 57 38 27 11
APXVAAR18_43-U 1.828 1.891 12.0 4.3 0 0 38 16
Screen 1.800 1.828 1 56.0 16.3 1 2184 1 646 1 40 1 17
Notes:
a
- Force coefficients determined from ASCE 7-10 figure 29.4-1 interpolation.
b _ F = qGCA1, ASCE 7-10 equation 29.4-1. Fully screened appurtenances will not experience wind loads.
5 of 20
Structural Analysis
SAC AE Design Group, Revision 0
2. Antenna Mount analysis
S 06/15/2018
5D06377A
RE
WI R EL £ 5$
Table 2.1: Pioe Loads
Loads D
lb
E
lb
P= 181 27
F= 0 65
R1 =R2 =P/2= 91 14
R1 =-P/5-F/2= -36 -38
R2 =-F-R1 = 36 -27
Mmu=FL/4+Pe= 181 108
Table 2.2: 2." Dia. Pine Section Pronertiec
Ag
(in)
I
(in 4)(in
S
3)(in)
r F
(ksi)
E
(ksi)
D
(in)
D/t Z
(in)
1.61 1.450 1.010 0.952 35 29000 2.88 15.2 1 1.370
Compressive Capacity: Flexural Capacity:
K = 1 l,= 0.07E/F = 58 compact
L = 60 in I = D/t = 15.2 < 0.45E/Fy
KL/r = 63.03 0.45E/F = 372.9
4.71(E/F)112 = 135.6 > 63.02521 M = FZ = 3996 lbs-ft
Fe it2E/(KL/r)2 72.06 ksi 0.9
Fcr= [0.658"]F, = 28.56 ksi 3596 lbs-ft
Pn FcrAg 45983 lbs
0.9
4P = 41385 lbs
6 of 20
Structural Analysis 06/15/2018
SAC AE Design Group, Revision 0 5006377A
RE
WIRELESS
Table 2.3: Member 1 Combined Stracc Ratio-,
Load Combo Pa/cPn Ma/bMn Ratio
1.41) 0.006 0.070 0.077
1.2D+E 1 0.006 0.091 0.096
Table 2.4: Reauired loads mount connection
Loading
Combinations
Vertical (y)
(lb)
Lateral (x)
(lb)
1.41) 127 51
1.20+E 122 81
The connection willi consists of (2) 1/2 Hilti Kwik 17 anchors w/2 mm. embedment per reaction.
Table 2.5: Mount connection.
Load Combina. V T V T V./VI T/T Combined
1.40 136 51 3813 4134 0.036 0.012 0.048
1.20+E 147 81 3813 4134 0.038 0.020 0.058
1/2" Diameter Hilti Stainless Steel KB-TZ Expansion Bolt Capacity with 2 inch embedment
Tension Capacity - Anchor Strength
AS N = 0.101 in
uta = 115 ksi
0.75
Nsa = AseNfuta = 11.62 kip
421\lsa = 8.711 kip
Pass
Pass
Passes
Passes
- 1/2 diam. Bolt
ACI 318 Eq. 17.4.1.2
Tension Capacity - Concrete Breakout
hef = 2.0 in
ANC. = 9hef2 = 36 in
36 in
l.Shet = 3.0 in
'Ped,N = 1.0
= 1.4
Cp,N = 1.0
17
A. 1.0
= 2500 psi
0.75
Nb = kcAa(f'c)0.5 hef1.5 = 2.404 kip
NCb = (ANJANco)4fedN4)cNtjJcpNNb = 3.324 kip
= 2.493 kip
Tension Capacity - Concrete Pullout
tljc,p = 1.0
Np,cr 3.18 kip
0.65
ACI 318 Eq. 17.4.2.5a
ACI 318 Section 17.4.2.6(b)
ACI 318 Eq. 17.4.2.7a
ACI 318 Eq. 17.4.2.1a
ACI 318 Section 17.4.3.6
7 of 20
Structural Analysis 06/15/2018
SAC AE Design Group, Revision 0 SD06377A
RE
WI R E L E S 6
N = Np,cr*(fJ2500)00S = 3.18 kip
N. = = 3.18 kip
= 2.067 kips
Shear Capacity - Anchor Strength
Vsa 6.88 kips
=
0.65
41Vsa 4.472 kips =
Shear Capacity - Concrete Breakout
Cal = 5.5 in
ca2 = 5.5 in
ha = 4.01n
vc = 3Cajha = 66 in ACI 318 Fig. R17.5.2.1b
2_
- AvcO = 4.Scai 136.1 in ACI 318 Eq. 17.5.2.1c
ed,V = 1.0 ACI 318 Eq. 17.5.2.6a
c,V = 1.0 ACI 318 Section 17.5.2.7
= 1.4 ACI 318 Equation 17.5.2.8
da = 0.5 in
le = 2.0 in ACI 318 Section 17.5.2.2
Vb = [7(Ie/d O.5 0.5 1.5 a! ua j"affc) (cai) = 4.212 kip ACI 318 Eq. 17.5.2.2a
Vb = 9Xa(Pc)0.5 (cai)1.5 = 5.804 kip ACI 318 Eq. 17.5.2.2b
0.65
Vcb = (AvjAvco)L))edvt.IJcvt))hvVb = 2.933 kip ACI 318 Eq. 17.5.2.1a
06 = 1.906 kip
Shear Capacity - Concrete pryout
kcP = 1.0 ACI 318 Section 17.5.3.1
NcP = NO = 3.324 kip ACI 318 Section 17.5.3.1 (a)
0.65
VCP = kNJ = . 3.324 kip ACI 318 Eq. 17.5.3.1a
42Vcp = 2.16 kip
Tensile Strength (min from all components) = 2067 lbs
Shear Strength (min from all components) = 1906 lbs
8 of 20
0340 6
1-El JSIV sdoj L67
(oq ad) sdoj SL17?
3
1-El DSIV sdDi S61'
AedeD ieaiis
0t8
=0
Aipedej uolsuaj
Apede 109 LOE-V Jaawe,a 8/E
S000 0066 0176S 6 3? M90+a
t7oO0 0066 0176S S E? ]LO+a
pauiqwo
(qi)
Uj
(qi) (qi) (qi) suoeuqwo
2U!peO
)PIP uo!pauuo :, IqeJ.
'aioJaqj fli.1S!Ufl .iad soq-nJq1 LOEV 8/E (17) Iseal le 10 SSU0D IIM UO!PBUUOJ
-speol aueuaindde aqj ioj aienbape SI ln4s!un
aql iiews aie spoi PJ!flbJ aqj aDU!S -ueds.Z e .ia,o SuipjaiA aioaq sq ?LLII Jo PeOl ieei e pue OWE/i iapun UO!paJp
9!M uedsp!w aqj le sql 069140 peoi le:)IlJaA e upuesqM 40 qedeD s! Inilslun aqj (pipee) ienuew jajnl3elnuew id s
LT 117 M90+0
01 517 3t0+O
(q 1)
ieiaiei
(qi) SUOIeUIqWOD
2u!peoi
speoi P!fl°H :E IqJ.
(asv U! UDAIS Sl lenuew panpejnuew U! ApedeD flJSIufl aDu!s) suoieuqwo osv suisn 'aJo4aiaqj
83 ST 0 IBOJ.
0 1 0 DS!LAJ
2? El 0 6171717fl
(q)
M
(q)
3
(q 1)
0
a3ueuJnddV
speol jejejel Inimun
o g it' IOi
0 1 17 DS!LAJ
O 9 LE 617Pt7flfli
(q)
M
NO
3
NO
0 aDueuaJndd
speo ieIA 1flJ4SiUfl aqej
peop aqeq kue ii!M SflJS!Ufl z aje
ajaql aouis 3WN suolsuawip aueuaindde aqj uo paseq xew Suol ,Zq ii!M 2n4s1ufl 6171717Sn8 (i) ii!M n.nsiufl iierv\ aij
uawssasse injislun flftJ E
S 3 1 3 m I M.
VLLE900S 0 UO!s!Aed 'dnoic u!sacI IV DVS
8103/51/90 S!SAI8UV ieinpnis
Structural Analysis 06/15/2018
SAC AE Design Group, Revision 0 5D06377A
RE
WIRELESS
0= 2
R/0= 1.485 kips (per bolt)
4. FRP screen analysis
Front angle analysis
WV
Table 4.1:FRP Angle Analysis
Load D E W
w=lb/ft 9 1 0
Wh= lb/ft 0 3 137
Mmax,y Wvl2/8 lb-ft 18 3 0
Mmaxx=Whl2/8' lb-ft 0 6 273
R2y Rmax,y 10Wvl/8 lb-ft 44 7 0
R2x=Rmaxx=10Whl/8= lb-ft 0 16 682.627
The front angle will be an FRP L3x3x3/8 angle.
L3X3x3/8 Series 500 FRP Angle Shear Capacity
1500 psi
A= 2.09 in
V=AF= 3135 lbs
13X3X3/8 Series 500 FRP Angle Moment Capacity
E = 2600000 psi
b/t= 8.00
Sx = 0.83 in3
F=E/(27*b/tO9S) 13356 psi <30,000, Ok!
Fb = FJ2.5 = 5342.4 psi
M = Fb*S. = 369.51 lb-ft
Table 4.2: FRP Angle Canacitv Check
Load Combination M,,JM= M,/M= V,,,,/V0= V,,jV= Combined
D+0.7E 0.012 0.052 0.015 0.005 0.065
D+0.6W 0.443 0.047 0.014 0.131 0.508
The connection to the screen frame will consist of (1) 5/8' Fibrebolt or approved equal with capacity as per attached
manufacturer specs with factor of safety of 4.
Structural Analysis 06/15/2018
SAC AE Design Group, Revision 0
Sa
SD06377A
RE
WIRELE$S
Table 4.3: Connection check
Load Combina. V. T V T V,/V,, TU/T Combined
D+0.7E 48 11 950 775 0.051 0.014 0.065
0+0.6W 44 410 950 775 0.046 0.528 0.575
See Enercalc for FRP Screen load calculation, not for analysis. Capacity of the L3x3x1/4 FRP angles making the frame is done
separately.
Using the maximum force experienced by a member as per Enercalc model and capacity of the governing FRP angle we have:
Pu= 427 lbs
Pn= 2414 lbs
Pu/Pn= 0.177 Pass
L3X3x1/4 Series 500 FRP Angle Axial Capacity
K= 1.00
r= 0.91 in
A = 1.42 in
b/t= 12
KL/r= 55.5
Fu = E/(27*b/t°95) = 9086.3 psi <30,000, Ok!
F = E/56(KL/r)°55 = 5099.7 psi
Fa = F/3.0 = 1699.9 psi
= Fa*A = 2413.8 lbs
Connection of FRP angles to back wall angle will consist of (1) 5/8' FRP thru-bolt per reaction. Using reactions from Enercalc we
have:
T= 392 lbs
T= 775 lbs
v,,= 394.9 lbs
V,= 950 lbs
T./T.= 0.506 Pass
V,/V,,= 0.416 Pass
The connection of the wall angle assumed to consist of 1/2 Diameter Hilti Stainless Steel KB-TZ Expansion Bolt at 48' o.c.
Therefore, using reactions from Enercalc we have:
T= 392 lbs
T= 2067 lbs
V= . 394.9 lbs
v0= 1906 lbs
0.397 Pass
All checks passed.
Passes
Passes
11 of 20
SAC AE Design Group, Inc. Project Title:
S3 5015 Shoreham P1, Ste 150 Engineer: Project ID:
! San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Group, Inc.
Printed: 18 JUN 2018, 1:35PM
2-D Frame File = Q:\$Struc\Projects\AE1516_T-Mobile L700\S006377A\SD06377A_Enerca?c_2018-06-15.ec6
ENERCALC, INC. 1983-2018, Build:10.18.1.31, Ver:1O.18.1.31 I
Description : Screen Force Calculation. Not for analysis.
1 0.0 0.0 Fixed 0
2 0.0 7.0 Fixed 0
3 2.333 7.0 Fixed 0
4 2.333 0.0 Fixed Fixed 0
5 0.0 3.50 Fixed 0
6 2.330 3.50 Fixed Fixed 0
Members...
Member Endpoint Joins Member Releases Specify Connectivity of Member Ends to Joints
Label Property Label I Joint J Joint Length
x I End y z (rotation) J End x y z (rotation)
A Column 1 5 3.500 Fixed Fixed Pinned Fixed Fixed Pinned
B Beam 2 3 2.333 Fixed Fixed Pinned Fixed Fixed Fixed
C Column 5 2 3.500 Fixed Fixed Pinned Fixed Fixed Pinned D Beam 1 4 2.333 Fixed Fixed Pinned Fixed Fixed Fixed
E Beam 5 4 4.206 Fixed Fixed Pinned Fixed Fixed Fixed
F Beam 5 6 2.330 Fixed Fixed Pinned Fixed Fixed Fixed
G Beam 2 . 6 4.205 Fixed Fixed Pinned Fixed Fixed Fixed
Member Stress Check Data...
Member Unbraced Lengths Slenderness Factors AISC Bending & Stability Factors
Label Lu:z It Lu:y K:z K:y Cm Cb
A 3.500 3.500 1.00 1.00 Internal Internal
B 2.333 2.333 1.00 1.00 Internal Internal
C 3.500 3.500 1.00 1.00 Internal 1.000
D 2.333 2.333 1.00 1.00 Internal 1.000
E 4.206 4.206 1.00 . 1.00 Internal 1.000
F 2.330 2.330 1.00 1.00 Internal 1.000
G 4.205 4.205 1.00 1.00 Internal 1.000
12 of 20
SAC AE Design Group, Inc. Project Title: 3 5015 Shoreham P1, Ste 150 Engineer: Project ID:
San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Group, Inc.
Printed: 18 JUN 2018, 1:35PM
1 2-D Frame File = Q:\$Stcuc\Prolects\.AE1516_T-Mobile L700\S006377A\SD06377A_Enercalc_2018-06.15.ec6
ENERCALC, INC. 1983-2018, Build:10.18.1.31, Ver:10.18.1.31 I
lIT Licensee SAC 4Wireless
Description : Screen Force Calculation. Not for analysis.
Materials...
Member Youngs Density Thermal Yield
Label ksi kcf in/degr ksi
Default 1.00 0.000 0.000000 1.00 FRP 2,600.00 0.120 0.000001 30.00
Steel 29,000.00 0.490 0.000007 50.00 Wood 1,800.00 0.035 1 0.000000 1 0.00
Wood Material Data...
Wood, Not Defined, Density= 0.035pci, FbT= 1000psi, FbC= 1000psi, Fv= 1000psi, Ft: 1000, Fc= 400psi, E Bend XX= 1800ksi, E BendMin XX:
1800ksi, E Beny YY= l800ksi, E BendMin YY= 1800ksi, E Axial: 1800ksi, Species=, Grade= Any, Class:
Member Sections...
Prop Label Group Tag Material Area Depth Width lxx lyy
Default Group Default 1.0 in12 0.0 in 0.0 in 1.0 in14 1.0 in"4
L3x3x1/4 Column FRP 1.440 ine2 3.0 in 3.0 in 1.230 inA4 1.230 ine4
L3x3x1/4 Beam FRP 1.440 ine2 3.0 in 3.0 in 1.230 inA4 1.230 mM
Joint Loads.... Note: Loads labeled 'Global Y" act downward (in "-Y" direction)
Load Load Magnitude
Joint Label Direction Dead Roof Live Live Snow Seismic Wind Earth
1 Global X -0.2050 k
1 Global Y 0.0240 k
2 Global Y 0.0240 k
2 Global X -0.2050 k
5 Global Y 0.0480 k
5 Global X -0.410 k
Strength/Stress Load Combinations ASCE 7-10
Load Combination Cd Load Combination Factors
Description Dead Roof Live Live Snow Seismic Wind Earth
+D+l-I 0.91 1 1.0 1.0
Automatically Apply 100 % of member self-weight as D in the +Global Y direction.
Reaction Load Combinations ASCE 7-10
Load Combination Load Combination Factors
Description Dead Roof Live Live Snow Seismic Wind Earth
+041 . 1.0 1.0
Automatically Apply 100 % of member self-weight as D in the +Global Y direction.
Deflection Load Combinations ASCE 7-10
Load Combination Load Combination Factors
Description Dead Roof Live Live Snow Seismic Wind Earth
+041 1.0 . 1.0
Automatically Apply 100 % of member self-weight as D in the +Global Y direction.
Extreme Joint Displacements Only Load Combinations giving maximum values are listed
Joint Displacements
Joint Label X Y Z in in Radians
1 -0.001533 -0.002826 0.0
Max D Only D Only
1 -0.001533 -0.002826 0.0
Min D Only 0 Only
2 -0.001793 -0.002206 0.0
Max D Only 0 Only
13 of 20
SAC AE Design Group, Inc. Project Title:
. 3 5015 Shoreham P1, Ste 150 Engineer: Project ID:
San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Group, Inc.
Printed: 18 JUN 2018, 1:35PM
1 2-D F .
.
File Q:\$Struc\Projects\.AE1516_T-Mobile L700\SD06377A\S006377A_Enercalc_2018-06-15.ec6
Lic.
ENERCALC, INC. 1983.2018, Build:10.18.1.31,Ver:10.18.1.31
Licensee SAC Wireless
Description : Screen Force Calculation. Not for analysis.
2 -0.001793 -0.002206 0.0
Min DOnly DOnly
3 0.0 0.0 0.0
Max D Only
3 0.0 ##IIIIII////IIIII/# '3258471,222
Min DOnly DOnly DOnly
4 0.0 0.0 .0000420
Max D Only D Only D Only
4 0.0 0.0 .0000420
Min D Only D Only 0 Only
5 -0.003185 -0.00260 0:0
Max D Only 0 Only
5 -0.003185 -0.00260 0.0
Min 0 Only D Only
14 of 20
SAC AE Design Group, Inc. Project Title:
ST 5015 Shoreham P1, Ste 150 Engineer: Project ID:
San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Gràup Inc.
Printed: 18 JUN 2018, 1:35PM
2-D Frame File = Q:\$StnjcProjeclsAE1516_T-MobiIe L700\SDO6377AS006377A_Enercalc_2018-06-15.ec6
ENERCALC, INC. 1983-2018, Build:1018.1.31, Ver:1018.1.31 I
Lic.
Description : Screen Force Calculation. Not for analysis.
Extreme Joint Displacements Only Load Combinations giving maximum values are listed
Joint Displacements
Joint Label X V Z in in Radians
6 0.0 0.0 .0000270
Max D Only 0 only D Only
6 0.0 0.0 .0000270
Min D Only D Only D Only
Extreme Joint Reactions Only Load Combinations giving maximum values are listed
Joint Reactions
Joint Label X V Z k k k-ft
Max
Mm
2
Max
Mm
3 0.2390
Max D Only
0.2390
Min 0 Only
4 0.1885 0.02083
Max 0 Only D Only
0.1885 0.02083
Min 0 Only oOnly
5 V
Max
Mm
6 0.3918 0.04777
Max 0 Only 0 Only
0.3918 0.04777
Min D Only 0 Only
Extreme Member End Forces Only Load Combinations giving maximum values are listed
Member" I " End Forces Member 'i" End Forces
Member Label Axial Shear Moment Axial Shear Moment
k k k-ft k k k-ft
A -0.02223 0.0 0.0 0.01803 0.0 0.0
Max D Only 0 Only D Only 0 Only D Only 0 Only
A -0.02223 0.0 0.0 0.01803 0.0 0.0
Min 0 Only 0 Only 0 Only 0 Only D Only 0 Only
B -0.2398 -0.003050 0.0 0.2398 0.000250 -0.001850
Max D Only D Only 0 Only D Only D Only D Only
B -0.2398 -0.003050 0.0 0.2398 0.000250 -0.001850
Min 0 Only 0 Only 0 Only D Only 0 Only 0 Only
C -0.03727 0.0 0.0 0.03307 0.0 0.0
Max D Only 0 Only D Only 0 Only 0 Only 0 Only
C -0.03727 0.0 0.0 0.03307 0.0 0.0
Min D Only 0 Only 0 Only 0 Only 0 Only 0 Only
D -0.2050 -0.001768 0.0 0.2050 -0.001032 -0.000858
Max 0 Only 0 Only 0 Only 0 Only 0 Only 0 Only
D -0.2050 -0.001768 0.0 0.2050 -0.001032 -0.000858
Min 0 Only D Only 0 Only D Only 0 Only 0 Only
E 0.03155 -0.001196 0.0 -0.02735 -0.001604 0.000858
Max 0 Only 0 Only 0 Only D Only 0 Only 0 Only
E 0.03155 -0.001196 0.0 -0.02735 -0.001604 0.000858
Min 0 Only 0 Only 0 Only D Only 0 Only 0 Only
F -0.4265 -0.001854 0.0 0.4265 -0.000942 -0.001063
Max 0 Only 0 Only D Only 0 Only 0 Only 0 Only
F -0.4265 -0.001854 0.0 0.4265 -0.000942 -0.001063
Min D Only 0 Only D Only 0 Only 0 Only D Only
15 of 20
SAC AE Design Group, Inc. Project Title:
3 5015 Shoreham P1, Ste 150 Engineer: Project ID:
. San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Group, Inc.
Punted: 18 JUN 2018, 1:35PM
2-0 Frame File = 0:\$StrijctProject.sE1516 1-Mobile L700\SD06377A\SD06377A_Enercalc_2018-06-15.ec6
ENERCALC, INC. 1983-2018, Build:10.18.1.31, Ver:10.18.1.31 I
lit
Description : Screen Force Calculation. Not for analysis.
Extreme Member End Forces . Only Load Combinations giving maximum values are listed
Member "I" End Forces Member " J " End Forces
Member Label Axial Shear Moment Axial Shear Moment k k k-ft k k k-ft
Ii U.Ub4bU -U.U0114 0.0 -O.0b040 -0.001b48 0.001050 Max 0 Only D Only D Only 0 Only D Only 0 Only
G 0.06460 -0.001148 0.0 -0.06040 -0.001648 0.001050 Mm 0 Only D Only D Only D Only D Only 0 Only
Extreme Member Forces Only Load Combinations giving maximum values are listed
Mmbr Label Axial Dist from "1" Joint Moment Dist from °l" Joint Shear Dist from "I" Joint
A 0.02223k 0.o ft 0.0k-ft 0.0 ft 0.0k 0.0 ft
Max 0 Only
A 0.01803k 3.50 ft 0.0k-ft 0.0 ft 0.0k 0.0 ft
Min 0 Only
B 0.2398k 0.0 ft 0.003850k-ft 2.333 ft -0.000250k 2.333 ft
Max 0 Only 0 Only 0 Only
B 0.2398k 0.0 ft 0.000144 k-ft 0.04761 ft -0.003050 k 0.0 ft
Min 0 Only 0 Only 0 Only
C 0.03727k 0.0 ft 0.0k-ft 0.0 ft 0.0k 0.0 ft
Max 0 Only
C 0.03307k 3.50 ft 0.0k-ft 0.o ft 0.0k 0.0 ft
Min U Only
D 0.2050k 0.0 ft 0.001302k-ft 1.476 ft 0.001032k 2.333 ft
Max 0 Only U Only U Only
D 0.2050k 0.0 ft 0.000163 k-ft 0.09522ft -0.001768 k 0.0 ft
Min DOnly DOnly DOnly
E -0.02735k 4.206 ft 0.001074k-ft 1.803 ft 0.001604k 4.206 ft
Max U Only U Only U Only
E -0.03155k 0.0 ft -0.000858k-ft 4.206 ft -0.001196k 0.0 ft
Min U Only U Only U Only
F 0.4265k 0.0 ft 0.001432k-ft 1.522ft 0.000942k 2.330 ft
Max U Only . U Only U Only
F 0.4265k 0.0 ft 0.000171 k-ft 0.09510 ft -0.001854k 0.0 ft
Min U Only U Only U Only
G -0.06040k 4.205 ft 0.000991 k-ft 1.716ft 0.001648 k 4.205 ft
Max D Only U Only U Only
G -0.06460k 0.0 ft -0.001050k-fl 4.205 ft -0.001148k 0.0 ft
Min DOnly U Only U Only
Member Stress Checks... Stress Checks per AISC 360-10 & NDS 2015
Member I Section a eria Material Max. Axial + Bending Stress Ratios Max. Shear Stress Ratios
I Label Label Load Combination Ratio Status Dist (ft) Load Combination Ratio Status Dist (ft)
A (.01umn steel Angle, JO ruano Laic 99.OUU KtlO> 1. (JUt) Angle, UD nano 1,a1c 99.000 Katlo> 1. 0.00
B Beam Steel Angle, Do Hand Cale 99.000 Ratio> 1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
C Column Steel Angle, Do Hand Cale 99.000 Ratio> 1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
D Beam Steel Angle, Do Hand Cale 99.000 Ratio >1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
E Beam Steel Angle, Do Hand Cale 99.000 Ratio> 1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
F Beam Steel Angle, Do Hand Cale 99.000 Ratio> 1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
G Beam Steel1 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00 Angle, Do Hand Cale 99.000 Ratio> 1. 0.00
16 of 20
SAC AE Design Group, Inc. Project Title:
T 5015 Shoreham P1, Ste 150 Engineer: Project ID:
1 San Diego, CA 92122 Project Descr:
(619)736-3766
AE Design Group, Inc.
Punted: lB JUN 2018, 1:35PM
2-D Frame File = Q:\$Struc\Projects\.AE1516_T-Mobile L700\S006377A\S006377A_Enercalc_2018-06-15.ec6
ENERCALC, INC. 1983-2018, Build:10.18.1.31, Ver:10.18.1.31
Description : Screen Force Calculation. Not for analysis.
17 of 20
UNISTRUT
P10O0 I
1W
413
711
ft T 3.2 i]915
41.3
It
2 2
Wt/100 Ft: 189 Lbs (281 kg/100 m)
Allowable Moment 5,070 In-Lbs (570 N.m)
12 Gauge Nominal Thickness .105(2.7mm)
P1001 [F I
1 W-1 b413I
-1 Hil. [HI 8
[
2 2
L!1
Wt/100 Ft: 378 Lbs (562 kg/100 m)
Allowable Moment 14,360 In-Lbs (1,620 Nm)
12 Nominal Thickness. 105 (2.7mm)
E I P1 000 H3
GaugeN
PI000KO
9/le" (14.3) Dia. Holes /i6" (14.3) Dia. Holes 60 (152.4) on Center
r,° (47.(' -- I W (47 -' --
Qbs 260kg _ WIJ100 Fl: 173 Lbs (257 kg/1 00 m) W1 /100 m) Wt/100 Ft: 190 Lbs (283kg/loom) Wt/100 Ft: 185 Lbs (275kg/100m)
P1000 SL P1000 T
Slots are
P1000 DS
Slots are 2 3/4" (69.9) x 'A'(22.2)
31,
Act e
ides
3'(76.2) x 13A2*(103)
'
(12.7)
W(/100 Ft: 185 Lbs (275kg/100m)
Slots are
1%'(28.6) x91le° (14.3)
2(5o8)1
Wt/100 Fl: 185 Lbs (275 kg/100 m)
Slots are
2 (50.9)x °Ie" (17.5)
3
4~~W- (38.1)
-
125.41
Wt/100 Ft: 185 Lbs (275 kg/100 m)
CHANNEL NUTS (REFER TO PAGES 73,74 FOR DsTFJLs) IF I
P1006-0832
P1006-1024
P1008T
P1006T1420
P1024 P3006-0832
P3006-1024
P3016-0632
P3016-0832
P1006-1420 P1010T
fgTv P1012S
P1023S P3006-1420 P3016-1024
P1007 P3007 P3016-1420
11311008 P3008
P1009 P3009
P1010 P1012
P1023 P3010
P1024S
Channel Finishes: DF, PL, GR, HG, PG, ZD; Standard Lengths: 10'& 20'
24 • -- 15/s" Framing System
U N ISTRUT
P1000. BEAM LOADING
Max. Allowable
Defl. at Uniform Loading at Deflection
Span Uniform Load Load Span/180 Spanl240 Span/360
In Lbs In Lbs Lbs Lbs
24 1,690 0.06 1,690 1,690 1,690
36 1,130 0.13 1,130 1,130 900
48 850 0.22 850 760 500
60 680 0.35 650 480 320
72 560 0.50 450 340 220
84 480 0.68 330 250 160
96 420 0.89 250 190 130
108 380 1.14 200 150 100
120 340 1.40 160 120 80
144 280 2.00 110 80 60
168 240 2.72 80 60 40
192 210 3.55 60 50 NR
216 190 4.58 50 40 NR
240 170 5.62 40 NR NR
P1000 - COLUMN LOADING
Unbraced
Max. Allowable
Load at Maximum Column Load Applied at C.G.
Height Slot Face K0.65 K0J0 KM
In Lbs Lbs Lbs Lbs
60 2,380 5,9104,690 ,960
72 2,080 4,840 3,800 2,400
96 1,670 3,480 2,110 1,660
108 1,510 3,050 &i0**
120 1,380 2,700
144 1,150 2O ,.,.J660
PI000/PI00I -ELEMENTS OF SECTION
Parameter P1000 P1001
Area ofSection 0.555 In2 1.111 In2
Axis 1-1
Moment of Inertia (I) 0.185 In4 0.928 In4
Section Modulus (S) 0.202 In3 0.571 In3
Radius of Gyration (r) 0.577 In 0.914 In
Axis 2-2
Moment of Inertia (I) 0.236 In' 0.471 In'
Section Modulus (S) 0.290 In3 0.580 In3
Radius of Gyration (r) 0.651 In 0.651 In
'P1001 - BEAM LOADING
Defi. at Uniform Loading at Deflection Max. Allowable Uniform
Span Uniform Load Load Span/180 Span/240 Span/360
In Lbs In Lbs Lbs Lbs
24 3,500* 0.02 3,500* 3,500* 3,500*
36 3,190 0.07 3,190 3,190 3,190
48 2,390 0.13 2,390 2,390 2,390
60 1,910 0.20 1,910 1,910 1,620
72 1,600 0.28 1,600 1,600 1,130
84 1,370 0.39 1,370 1,240 830
96 1,200 0.51 1,200 950 630
108 1,060 0.64 1,000 750 500
120 960 0.79 810 610 410
144 800 1.14 560 420 280
168 680 1. 410 310 210
192 600 11L02 - 320 240 160
216 530 V,'jY 250 190 130
240 480 t-N .16 200 156 100
PIXC
J
tLUMN
Max. Allowable -Maximum Column Load Applied atC.G. ed Load
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs
24 6,430 24,280 23,610 22,700 21,820
36 6,290 22,810 21,820 20,650 19,670
48 6,160 21,410 20,300 18,670 16,160
60 6,000 20,210 18,670 15,520 12,390
72 5,620 18,970 16,160 12,390 8,950
84 5,170 16,950 13,630 9,470 6,580
96 4,690 14,890 11,190 7,250 5,040
108 4,170 12,850 8,950 5,730 3,980
120 3,690 10,900 7,250 4,640 **
144 2,930 7,630 5,040 **
Notes:
* Load limited by spot weld shear.
KL/r > 200
NR = Not Recommended.
Beam loads are given in t.gjp.j uniform load (N Lbs) not uniform load (w lbs/ft or
w lbs/in).
Beam loads are based on a simple span and assumed lobe adequately laterally
braced. Unbraced spans can reduce beam load carrying capacity. Refer to Page 62
for reduction factors for unbraced lengths.
For pierced channel, multiply beam loads by the following factor:
'KO' Series.......95% 'T' Series ..........85%
'HS Series.......90% SL" Series........85%
"1-13' Series........90% n DS Series........70%
"WT" Series.......85%
Deduct channel weight from the beam loads.
For concentrated midspan point loads, multiply beam loads by 50% and the
corresponding deflection by 80%. For other load conditions refer to page 18.
All beam loads are for bending about Axis 1.1.
11/8" Framing System - -- 25
TABLE 4-DESIGN INFORMATION, STAINLESS STEEL KB-TZ
Nominal anchor diameter DESIGN INFORMATION Symbol Units 3/8 112 18 3/4
AnchorO.D. d,(d,) in. 0.375 0.5 0.625 0.75
(mm) (9.5) (12.7) (15.9) (19.1)
Effective mm. embedment' h.t in. 2 2 31/4 31/8 4 33/4 43/4
(mm) (51) (51) (83) (79) (102) (95) (121)
Mi. member thickness h,,,,, in. 45 I 6
I
618 I 5 6 8 I 618
I
8
(mm) (102) I (127) (102) (152) (152) (203) (127) (152) (203) (152) (203) (203)
in. 4 /8 3 I 5 /3 41/2 71/2 6 7 87/8 6 10 I 7 9 Critical edge distance c81 I I (mm) (111) I (98) (140) I
I (114) 1 (191) I (152) (178) (225) (152) (254) (178) (229)
in. 21/2 2 /8 2'I8 31/ 2 /8 41/ 4
Mm. edge distance
C (mm) (64) (73) (54) (83) (60) (108) (102)
in. 5 53/ 51/ 17 51/ 10 81/2 tars ~ (mm) (127) (146) (133) (140) (140) (254) (216)
in. 21/4 2 /8 2 2/4 23/e 5 4 S (mm) (57) (73) (51) (70) (60) (127) (102) Mm. anchor spacing in. 31/2 4'/2 31/ 41/8 41/ 91/2 7 for c a (mm) (89) (114) (83) (105) (108) (241) (178)
in. 2 /8 2 /8 4 3/ 4/ 4/ 53/4
Mm. hole depth in concrete h. (mm) (67) (67) (102) (98) (121) (117) (146)
Mm. specified yield strength
Win 92,000 92,000 92 00 76,125
fy (N/mm2) (634) (634) (525)
Mm. specified ult. Strength
lb/in2 115,000 115,000 115,000 101,500
(N/mm2) (793) (793) (700)
Effective tensile stress area A,,N in' 0.052 0.101 0.162 0.237
(mm2) (33.6) (65 0 (104.6) (152.8)
Steel strength in tension N,, lb 5,968 17,880 24,055
(kN) (26.6) (82.9) (107.0)
Steel strength in shear V. lb 4,720 9,870 15,711
(kN) (43.9) (69.9)
strength in tension, lb 8,110Pullout I 5,840 I NA seismic2 N8,,
I (36.1)(kN) (26.0)
Steel strength in shear, seismic2 (kN)
lb
42,340 ,CY23%
2,825 6,880 9,350 12,890
(30.6) (41.6) (57.3)
Pullout strength uncracked
concrete3
lb NA NA 5,760 NA I 12,040
(kN) Np,,,,,
____________ (25.6) (53.6)
Pullout strength cracked lb 3,180 NA NA 5,840 8,110 NA concrete (14.1) (26.0) (36.1) I
Anchorcategory4 1
Effectiveness factor k,,, u uncracked concrete 24
17 24 17 171 17 24 17 Effec ivenessfactork,,crackconcrete
C.N k,,,,,/kc,°
Strength reduction factor for tens , s re 0.75 modes7
Strength reduction factor 0 for shear, s el failure modes7 0.65
Strength reduction 0 factor for tension, concrete failure 0.65 0.55 0.65 modes, Condition Be I
Coefficient for pryout strength, k, 1.0 2.0
Strength reduction 0 factor for shear, concrete failure 0.70 modes, Condition B8
Axial stiffness in service load fi,,,, lb/in. 120,000
range° I I fi lb/in. 90,000
For SI: 1 inch = 25.4 mm, 1 lbt = 4.45 N, 1 psi = 0.006895 MPa For pound-inch units: 1 mm = 0.03937 inches.
'See Fig. 2.
2See Section 4.1.8 of this report. NA (not applicable) denotes that this value does not control for design.
3For all design cases 'P,=1.0. NA (not applicable) denotes that this value does not control for design. See Section 4.1.4 of this report.
'See ACI 318-14 17.3.3 or ACI 318-11 D.4.3, as applicable.
5See ACI 318-14 17.4.2.2 or ACI 318-11 0.5.2.2, as applicable.
6For all design cases 'PC.N =1.0. The appropriate effectiveness factor for cracked concrete (k,,) or uncracked concrete (k,,) must be used.
7The KB-TZ is a ductile steel element as defined by ACI 318 0.1.
8For use with the load combinations of ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2, as applicable. Condition B applies where supplementary reinforcement in
conformance with ACI 318-14 17.3.3(c) or ACI 318-11 0.4.3(c), as applicable, is not provided, or where pullout or pryout strength governs. For cases where the
presence of supplementary reinforcement
can be verified, the strength reduction factors associated with Condition A may be used.
8Mean values shown, actual stiffness may vary considerably depending on concrete strength, loading and geometry of application.
20 of 20
DocuSlgri Envelope ID: EFB89FF9-28BF-4643-83C1-535B484FF008
SAN DIEGO REGIONAL OFFICE USE ONLY
(0.) HAZARDOUS MATERIALS r7570
QUESTIONNAIRE BP DATE I 1
.
BusIness Name Business Contact T-MobiieWe LLC uJth OBO T.moblle Telephone ft 4368
Project Address (include suite) City Code AFrPf#
V 2875LKERAve.Bast . CARLSBAD . '- 92008 209-083-10-00
Mailing Address (include suite) City State Zip Code Plan File
5015 SHOREMAMPLACE, SUITE 150 SAN DIEGO CA 92122
Project Contact Applicant E-mail V LAUREN RICHARDS LAUREN.RLCHARDS@SACW.COM
-
480.735-4968
The following questions represent the raciiis activities, NUF ane specinc projecit ue5cnpg0n.
PMT I: FIRE DEPA?TMEPff - HA US M47ERIAL3 VISION: OCCUPANCY CLMSIflQATiON: (net eeuired f9r eegJtcb Within the City of Sen.
DIURI: Indicate by circling the item whether your business will use, process, or store any of the following hazaroua materIals. If any of the Items are circled,
appncant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. NO NEW
BATTERIBS/GENSaATO
TO BE
Occupancy Rating: Facility's Square Footage (including proposed project): INSTALLED] 120
Explosive or Bloating Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives
Compressed Gases S. Oxidizers 10. Cryogenics
3, Flammable/Combustible Liquids 7. Pyrophorice 11. Highly Toxic or Todd Materials Thee
4. Flammable Solids . 8. Unstable Reectives 12, Radloactives
PAMI II: N DIEGO COUNTY DEPTM.ENT O NV1ONMgNTPIft.. HTI4 — jARUQI,S UiVIIVN IPMU1
yes, applicant must contact theCounty of San Diego Hazardous Materials DIvision, 5500 Overland Avenue. Suite 170, Is
IT me answer to any CT me
San Diego, CA 92123. questions Call (858) 505.6700 prior to thelesuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CatARP Exempt
YES NO (for now Construction orremodeling projects) .... - 1
0 Is your business listed on the reverse side of this torn,? (check all that apply). Date Initials
0 ] Will your business dispose of Hazardous Substances or Medical Waste in any amount?
0 i Will your business store or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500 0 CaiARP Required
pounds and/or 200 cubic feet?
0 Will your business store or handle carcinogenalrepreductive toxins In any quantity? Data initials
0 [ Will your business use an existing or Install an underground storage tank?
8. 0 ( Will your business store or handle Regulated Substances (CeiARP)? 0 CalARP Complete
7. 0 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
B. 0 t Will your business store petroleum In tanks or containers at your facility with a total facility storage capacity equal to Date milieu
or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
PART Ill., SAN DIEGO COUNTY AIR POLLUTION COI(f101. DISTRICT fAPCD)1 The following questions are Intended to Identify the majority of air pollution
Issues at the planning stage. Your project may require additional measures not tdentmtied by these questions. Some residential projects may be exempt from APCD
requirements. If yes is answered tar either questions 1, 2 or 5 or for more comprehensive requirements, please contact APCD at aocdcomaithsdcountv.caAov
(858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92131,
YES NO
0 Will the project dIsturb 100 square feet or more of existing building materials?
0 L!i Will any load supporting structural members be removed?
0 (ANSWER ONLY IF QUESTION 1 or219 YES) Has an asbestos survey been performed by an lndMdual that has psasodan EPA-approved
building inspector course?
4, 0 ( (ANSWER ONLY IF QUESTION I or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, a
notification may be required at least 10 working days prior to commencing asbestos removal. Additionally, a notification may be required prior to
the removal of a load supporting structural member(s) regardless of the presence of asbestos.
5. 0 Will the project or associated construction equipment emit air contaminants? See the reverse aide of this form for typical equipment requiring an
APCD permit. If yes, contact APCD prior to the issuance of a building permit.
6, 0 L!i (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located wIthin 1,000 feet of a school
irtefly-èIãrlbe bu&ñIiiáótIIties: Briefly descrlbo01bP6ti4d projet.
T-Mobile Wireless FaCi1f4' [ Modification to existing antennas at aT-Mobile wireless facility
are under to1j1e best of my knowledge and and correct
Lauren 06 12
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION' FOR OFFICAL USE ONLY:
BY: ________________________________ . DATE:.__,l
Xe1J r. •5 •NFORMAflea ncauinas RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR occupxecv -
/4'4.ouvn'.ve, APCD . COUNIY-HMD APCD - COLJNVf.HMD APCD . . - <)
, REVIEWED 0 çi (an C
7JSIGIAi1JRE (
DATE
V
A -exempts businesses from completing or updating a Nezardous eaiarenais eusiness tian. umar permimng iequirumsms may anti appiy
HM-9171 (9/18) County of San Diego - DEN - Hazardous Materials Division